Observium_CE/mibs/newtec/NEWTEC-TSANALYSER-MIB

540 lines
18 KiB
Plaintext

NEWTEC-TSANALYSER-MIB DEFINITIONS ::= BEGIN
IMPORTS
Unsigned32,
Counter64,
Integer32,
MODULE-IDENTITY,
OBJECT-IDENTITY,
OBJECT-TYPE
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
NtcAlarmState,
NtcEnable
FROM NEWTEC-TC-MIB
ntcFunction
FROM NEWTEC-MAIN-MIB;
--
-- Module Identification
--
ntcTsAnalyser MODULE-IDENTITY
LAST-UPDATED "201804041000Z"
ORGANIZATION "Newtec Cy"
CONTACT-INFO
"Newtec Cy
Postal: Newtec Cy
Laarstraat 5
B-9100 Sint-Niklaas
Belgium
Tel: +32 3 780 65 00
Fax: +32 3 780 65 49
Web: www.newtec.be
E-mail: techsupport@newtec.be"
DESCRIPTION
"Newtec modular MIB containing definitions for transport stream analyser
functionality."
REVISION "201804041000Z"
DESCRIPTION
"Cosmetic change in units of error counters"
REVISION "201707101200Z"
DESCRIPTION
"ntcTsAnlyEPid added"
REVISION "201612051200Z"
DESCRIPTION
"ntcTsAnlyPidCtuCntErrorCntr column added to ntcTsAnlyPid table"
REVISION "201409090900Z"
DESCRIPTION
"descriptions adapted"
REVISION "201303271000Z"
DESCRIPTION
"Release for M6100 R1.3"
REVISION "201206281200Z"
DESCRIPTION
"Release for M6100 R1.2"
::= { ntcFunction 1400 }
--
-- Top-Level Structure
--
-- ntcTsAnalyser content
ntcTsAnlyObjects OBJECT-IDENTITY
STATUS current
DESCRIPTION "Container holding ntcTsAnlyObjects definitions."
::= { ntcTsAnalyser 1 }
ntcTsAnlyConformance OBJECT-IDENTITY
STATUS current
DESCRIPTION "Conformance requirements."
::= { ntcTsAnalyser 2 }
-- ntcTsAnlyObjects content
ntcTsAnlyAlarm OBJECT-IDENTITY
STATUS current
DESCRIPTION "Container holding ntcTsAnlyAlarm definitions."
::= { ntcTsAnlyObjects 6 }
-- ntcTsAnlyConformance content
ntcTsAnlyConfCompliance OBJECT-IDENTITY
STATUS current
DESCRIPTION "Device compliance statements."
::= { ntcTsAnlyConformance 1 }
ntcTsAnlyConfGroup OBJECT-IDENTITY
STATUS current
DESCRIPTION "Groups used by device compliance statements."
::= { ntcTsAnlyConformance 2 }
--
-- Managed Objects
--
ntcTsAnlyEble OBJECT-TYPE
SYNTAX NtcEnable
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable Transport Stream Analyzer."
DEFVAL { off }
::= { ntcTsAnlyObjects 1 }
ntcTsAnlyReset OBJECT-TYPE
SYNTAX INTEGER { running(0), reset(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset Transport Stream Analyzer"
DEFVAL { running }
::= { ntcTsAnlyObjects 2 }
ntcTsAnlyEstimatedTsRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the measured TS bit rate in bps. Current devices support a range of 0
to 2500000000 bps."
::= { ntcTsAnlyObjects 3 }
ntcTsAnlyPidTable OBJECT-TYPE
SYNTAX SEQUENCE OF NtcTsAnlyPidEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing all detected PID's of the incoming traffic stream with
corresponding measurements."
::= { ntcTsAnlyObjects 4 }
ntcTsAnlyPidEntry OBJECT-TYPE
SYNTAX NtcTsAnlyPidEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row of the ntcTsAnlyPidTable."
INDEX { ntcTsAnlyPidPid }
::= { ntcTsAnlyPidTable 1 }
NtcTsAnlyPidEntry ::= SEQUENCE {
ntcTsAnlyPidPid Unsigned32,
ntcTsAnlyPidType INTEGER,
ntcTsAnlyPidPIDRate Unsigned32,
ntcTsAnlyPidContinuityError INTEGER,
ntcTsAnlyPidTransportError INTEGER,
ntcTsAnlyPidCtuCntErrorCntr Counter64
}
ntcTsAnlyPidPid OBJECT-TYPE
SYNTAX Unsigned32 (0..8190)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PID"
::= { ntcTsAnlyPidEntry 1 }
ntcTsAnlyPidType OBJECT-TYPE
SYNTAX INTEGER { others(0), video(1), audio(2), privateSection(3), pesPrivate(4), mheg(5), dsmCc(6), h2221(7), mpe(8), auxiliary(9), slOrFlexMux(10), sdp(11), metadata(12), ipmp(13), userPrivate(14), pat(15), cat(16), tsdt(17), nitOrSt(18), sdtOrBatOrSt(19), eitOrStCit(20), rstOrSt(21), tdtOrTotOrSt(22), netwSync(23), rnt(24), inband(25), measurement(26), dit(27), sit(28), null(29), othersOrGhost(30), pmt(31), visual(32), srm(33), ecm(34), emm(35) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PID Type"
::= { ntcTsAnlyPidEntry 2 }
ntcTsAnlyPidPIDRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PID Rate for a specific stream."
::= { ntcTsAnlyPidEntry 3 }
ntcTsAnlyPidContinuityError OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Continuity Count Error"
::= { ntcTsAnlyPidEntry 4 }
ntcTsAnlyPidTransportError OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transport Error"
::= { ntcTsAnlyPidEntry 5 }
ntcTsAnlyPidCtuCntErrorCntr OBJECT-TYPE
SYNTAX Counter64
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of packets with a continuity count error."
::= { ntcTsAnlyPidEntry 6 }
ntcTsAnlyPcrPidTable OBJECT-TYPE
SYNTAX SEQUENCE OF NtcTsAnlyPcrPidEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of PCR PID's with detailled time measurements."
::= { ntcTsAnlyObjects 5 }
ntcTsAnlyPcrPidEntry OBJECT-TYPE
SYNTAX NtcTsAnlyPcrPidEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row of the ntcTsAnlyPcrPidTable."
INDEX { ntcTsAnlyPcrPidPid }
::= { ntcTsAnlyPcrPidTable 1 }
NtcTsAnlyPcrPidEntry ::= SEQUENCE {
ntcTsAnlyPcrPidPid Unsigned32,
ntcTsAnlyPcrPidPcrIntervalTime Unsigned32,
ntcTsAnlyPcrPidPcrRepeatError INTEGER,
ntcTsAnlyPcrPidPcrAccuracyError INTEGER,
ntcTsAnlyPcrPidMinJitter Integer32,
ntcTsAnlyPcrPidMaxJitter Integer32,
ntcTsAnlyPcrPidMinHoldJitter Integer32,
ntcTsAnlyPcrPidMaxHoldJitter Integer32,
ntcTsAnlyPcrPidRateOffset Unsigned32,
ntcTsAnlyPcrPidPcrRate Unsigned32
}
ntcTsAnlyPcrPidPid OBJECT-TYPE
SYNTAX Unsigned32 (0..8190)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PID"
::= { ntcTsAnlyPcrPidEntry 1 }
ntcTsAnlyPcrPidPcrIntervalTime OBJECT-TYPE
SYNTAX Unsigned32 (0..9999999)
UNITS "ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured interval time (in milliseconds) between 2 PCR packets."
::= { ntcTsAnlyPcrPidEntry 2 }
ntcTsAnlyPcrPidPcrRepeatError OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCR Repetition Error is raised when the spacing between two consecutive PCR
values is more than 40ms. The condition can occur when PCR packets get lost or
when PCR packets are not present at a sufficient rate."
::= { ntcTsAnlyPcrPidEntry 3 }
ntcTsAnlyPcrPidPcrAccuracyError OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The PCR Accuracy error is raised when the PCR accuracy exceeds +/- 500nsec.
The definition of the alarm is taken from TR101290."
::= { ntcTsAnlyPcrPidEntry 4 }
ntcTsAnlyPcrPidMinJitter OBJECT-TYPE
SYNTAX Integer32 (-9999999..9999999)
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum value of PCR_AC (nanoseconds) over the last second."
::= { ntcTsAnlyPcrPidEntry 5 }
ntcTsAnlyPcrPidMaxJitter OBJECT-TYPE
SYNTAX Integer32 (-9999999..9999999)
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Max Jitter PCR_AC (nanoseconds) measured over the last second."
::= { ntcTsAnlyPcrPidEntry 6 }
ntcTsAnlyPcrPidMinHoldJitter OBJECT-TYPE
SYNTAX Integer32 (-9999999..9999999)
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum measured PCR_AC value (in nanoseconds) computed since the last
reset."
::= { ntcTsAnlyPcrPidEntry 7 }
ntcTsAnlyPcrPidMaxHoldJitter OBJECT-TYPE
SYNTAX Integer32 (-9999999..9999999)
UNITS "ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum measured PCR_AC value (in nanoseconds) computed since the last
reset."
::= { ntcTsAnlyPcrPidEntry 8 }
ntcTsAnlyPcrPidRateOffset OBJECT-TYPE
SYNTAX Unsigned32
UNITS "ppm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rate Offset in PPM of the inband clock companed to the local clock. (ASI:
local clock, TS over IP: configured bitrate)"
::= { ntcTsAnlyPcrPidEntry 9 }
ntcTsAnlyPcrPidPcrRate OBJECT-TYPE
SYNTAX Unsigned32
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCR Rate (Mb/s) calculated by using the inband PCR timing information."
::= { ntcTsAnlyPcrPidEntry 10 }
ntcTsAnlyAlmSyncLoss OBJECT-TYPE
SYNTAX NtcAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm indicating that the synchronization with the Transport-Stream (TS) has
been lost. This conditions occurs when 2 or more consecutive corrupted SYNC
bytes are received. This variable indicates the current status of the alarm."
::= { ntcTsAnlyAlarm 1 }
ntcTsAnlyAlmSyncByte OBJECT-TYPE
SYNTAX NtcAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This alarm is raised when a single corrupted SYNC byte is detected and cleared
when the next correct one appears. This variable indicates the current status
of the alarm."
::= { ntcTsAnlyAlarm 2 }
ntcTsAnlyAlmPat OBJECT-TYPE
SYNTAX NtcAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This alarm indicates that the 'Program Association Table' (PAT) can not be
detected properly in the stream. The PAT table id (0x00) should be detected in
a PID 0x0000 at least every 0.5 s. This variable indicates the current status
of the alarm."
::= { ntcTsAnlyAlarm 3 }
ntcTsAnlyAlmContinuityCount OBJECT-TYPE
SYNTAX NtcAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This alarm is raised when packets arrive out of sequence, get dropped or occur
more than once. This variable indicates the current status of the alarm."
::= { ntcTsAnlyAlarm 4 }
ntcTsAnlyAlmTransport OBJECT-TYPE
SYNTAX NtcAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This alarm condition is detected when the 'Transport Error indicator'-bit in
the TS-Header is set to '1' for a specific PID. The alarm condition is cleared
when no Transport Error indication is detected for 5 sec. This variable
indicates the current status of the alarm."
::= { ntcTsAnlyAlarm 5 }
ntcTsAnlyAlmPcrRepetition OBJECT-TYPE
SYNTAX NtcAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This alarm is raised if the spacing between two consecutive PCR values is more
than 40ms. The condition can occur when PCR packets get lost or when PCR
packets are not present at a sufficient rate. This variable indicates the
current status of the alarm."
::= { ntcTsAnlyAlarm 6 }
ntcTsAnlyAlmPcrDiscontinuity OBJECT-TYPE
SYNTAX NtcAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This alarm indicates that the difference between two consecutive PCR values
exceeds the range [0-100] ms, while the 'discontinuity indicator' bit is not
set. This bit in the Adaptation Field should trigger a reset of the PCR
evaluation functionality. This variable indicates the current status of the
alarm."
::= { ntcTsAnlyAlarm 7 }
ntcTsAnlyAlmPcrAccuracy OBJECT-TYPE
SYNTAX NtcAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This alarm condition occurs when the PCR accuracy exceeds +/- 500nsec. The
definition of the alarm is taken from TR101290. This variable indicates the
current status of the alarm."
::= { ntcTsAnlyAlarm 8 }
ntcTsAnlyEPidTable OBJECT-TYPE
SYNTAX SEQUENCE OF NtcTsAnlyEPidEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table which contains PIDs on which an error has been detected."
::= { ntcTsAnlyObjects 7 }
ntcTsAnlyEPidEntry OBJECT-TYPE
SYNTAX NtcTsAnlyEPidEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A conceptual row of the ntcTsAnlyEPidTable."
INDEX { ntcTsAnlyEPidPid }
::= { ntcTsAnlyEPidTable 1 }
NtcTsAnlyEPidEntry ::= SEQUENCE {
ntcTsAnlyEPidPid Unsigned32,
ntcTsAnlyEPidType INTEGER,
ntcTsAnlyEPidCtuCntErrorCntr Counter64,
ntcTsAnlyEPidContinuityError INTEGER,
ntcTsAnlyEPidTransportError INTEGER
}
ntcTsAnlyEPidPid OBJECT-TYPE
SYNTAX Unsigned32 (0..8190)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PID"
::= { ntcTsAnlyEPidEntry 1 }
ntcTsAnlyEPidType OBJECT-TYPE
SYNTAX INTEGER { others(0), video(1), audio(2), privateSection(3), pesPrivate(4), mheg(5), dsmCc(6), h2221(7), mpe(8), auxiliary(9), slOrFlexMux(10), sdp(11), metadata(12), ipmp(13), userPrivate(14), pat(15), cat(16), tsdt(17), nitOrSt(18), sdtOrBatOrSt(19), eitOrStCit(20), rstOrSt(21), tdtOrTotOrSt(22), netwSync(23), rnt(24), inband(25), measurement(26), dit(27), sit(28), null(29), othersOrGhost(30), pmt(31), visual(32), srm(33), ecm(34), emm(35) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PID Type"
::= { ntcTsAnlyEPidEntry 2 }
ntcTsAnlyEPidCtuCntErrorCntr OBJECT-TYPE
SYNTAX Counter64
UNITS "packets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the number of packets with a continuity count error."
::= { ntcTsAnlyEPidEntry 3 }
ntcTsAnlyEPidContinuityError OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Continuity Count Error"
::= { ntcTsAnlyEPidEntry 4 }
ntcTsAnlyEPidTransportError OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Transport Error"
::= { ntcTsAnlyEPidEntry 5 }
--
-- Module Conformance
--
ntcTsAnlyConfGrpV1Standard OBJECT-GROUP
OBJECTS {
ntcTsAnlyEble,
ntcTsAnlyReset,
ntcTsAnlyEstimatedTsRate,
ntcTsAnlyPidType,
ntcTsAnlyPidPIDRate,
ntcTsAnlyPidContinuityError,
ntcTsAnlyPidTransportError,
ntcTsAnlyPidCtuCntErrorCntr,
ntcTsAnlyPcrPidPcrIntervalTime,
ntcTsAnlyPcrPidPcrRepeatError,
ntcTsAnlyPcrPidPcrAccuracyError,
ntcTsAnlyPcrPidMinJitter,
ntcTsAnlyPcrPidMaxJitter,
ntcTsAnlyPcrPidMinHoldJitter,
ntcTsAnlyPcrPidMaxHoldJitter,
ntcTsAnlyPcrPidRateOffset,
ntcTsAnlyPcrPidPcrRate,
ntcTsAnlyAlmSyncLoss,
ntcTsAnlyAlmSyncByte,
ntcTsAnlyAlmPat,
ntcTsAnlyAlmContinuityCount,
ntcTsAnlyAlmTransport,
ntcTsAnlyAlmPcrRepetition,
ntcTsAnlyAlmPcrDiscontinuity,
ntcTsAnlyAlmPcrAccuracy,
ntcTsAnlyEPidType,
ntcTsAnlyEPidCtuCntErrorCntr,
ntcTsAnlyEPidContinuityError,
ntcTsAnlyEPidTransportError
}
STATUS current
DESCRIPTION
"Managed objects that constitute version 1 of a system device with standard capabilities."
::= { ntcTsAnlyConfGroup 1}
ntcTsAnlyConfCompV1Standard MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for Newtec device MIB implementations."
MODULE -- this module
MANDATORY-GROUPS
{
ntcTsAnlyConfGrpV1Standard
}
::= { ntcTsAnlyConfCompliance 1 }
END