NEWTEC-TSANALYSER-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Unsigned32,
|
|
Counter64,
|
|
Integer32,
|
|
MODULE-IDENTITY,
|
|
OBJECT-IDENTITY,
|
|
OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
|
|
NtcAlarmState,
|
|
NtcEnable
|
|
FROM NEWTEC-TC-MIB
|
|
|
|
ntcFunction
|
|
FROM NEWTEC-MAIN-MIB;
|
|
|
|
|
|
--
|
|
-- Module Identification
|
|
--
|
|
|
|
ntcTsAnalyser MODULE-IDENTITY
|
|
LAST-UPDATED "201804041000Z"
|
|
ORGANIZATION "Newtec Cy"
|
|
CONTACT-INFO
|
|
"Newtec Cy
|
|
Postal: Newtec Cy
|
|
Laarstraat 5
|
|
B-9100 Sint-Niklaas
|
|
Belgium
|
|
|
|
Tel: +32 3 780 65 00
|
|
Fax: +32 3 780 65 49
|
|
Web: www.newtec.be
|
|
E-mail: techsupport@newtec.be"
|
|
DESCRIPTION
|
|
"Newtec modular MIB containing definitions for transport stream analyser
|
|
functionality."
|
|
|
|
REVISION "201804041000Z"
|
|
DESCRIPTION
|
|
"Cosmetic change in units of error counters"
|
|
REVISION "201707101200Z"
|
|
DESCRIPTION
|
|
"ntcTsAnlyEPid added"
|
|
REVISION "201612051200Z"
|
|
DESCRIPTION
|
|
"ntcTsAnlyPidCtuCntErrorCntr column added to ntcTsAnlyPid table"
|
|
REVISION "201409090900Z"
|
|
DESCRIPTION
|
|
"descriptions adapted"
|
|
REVISION "201303271000Z"
|
|
DESCRIPTION
|
|
"Release for M6100 R1.3"
|
|
REVISION "201206281200Z"
|
|
DESCRIPTION
|
|
"Release for M6100 R1.2"
|
|
::= { ntcFunction 1400 }
|
|
|
|
|
|
--
|
|
-- Top-Level Structure
|
|
--
|
|
|
|
-- ntcTsAnalyser content
|
|
|
|
ntcTsAnlyObjects OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Container holding ntcTsAnlyObjects definitions."
|
|
::= { ntcTsAnalyser 1 }
|
|
|
|
ntcTsAnlyConformance OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Conformance requirements."
|
|
::= { ntcTsAnalyser 2 }
|
|
|
|
-- ntcTsAnlyObjects content
|
|
|
|
ntcTsAnlyAlarm OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Container holding ntcTsAnlyAlarm definitions."
|
|
::= { ntcTsAnlyObjects 6 }
|
|
|
|
-- ntcTsAnlyConformance content
|
|
|
|
ntcTsAnlyConfCompliance OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Device compliance statements."
|
|
::= { ntcTsAnlyConformance 1 }
|
|
|
|
ntcTsAnlyConfGroup OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Groups used by device compliance statements."
|
|
::= { ntcTsAnlyConformance 2 }
|
|
|
|
|
|
--
|
|
-- Managed Objects
|
|
--
|
|
|
|
ntcTsAnlyEble OBJECT-TYPE
|
|
SYNTAX NtcEnable
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable or disable Transport Stream Analyzer."
|
|
DEFVAL { off }
|
|
::= { ntcTsAnlyObjects 1 }
|
|
|
|
ntcTsAnlyReset OBJECT-TYPE
|
|
SYNTAX INTEGER { running(0), reset(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset Transport Stream Analyzer"
|
|
DEFVAL { running }
|
|
::= { ntcTsAnlyObjects 2 }
|
|
|
|
ntcTsAnlyEstimatedTsRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "bps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the measured TS bit rate in bps. Current devices support a range of 0
|
|
to 2500000000 bps."
|
|
::= { ntcTsAnlyObjects 3 }
|
|
|
|
ntcTsAnlyPidTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NtcTsAnlyPidEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing all detected PID's of the incoming traffic stream with
|
|
corresponding measurements."
|
|
::= { ntcTsAnlyObjects 4 }
|
|
|
|
ntcTsAnlyPidEntry OBJECT-TYPE
|
|
SYNTAX NtcTsAnlyPidEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row of the ntcTsAnlyPidTable."
|
|
INDEX { ntcTsAnlyPidPid }
|
|
::= { ntcTsAnlyPidTable 1 }
|
|
|
|
NtcTsAnlyPidEntry ::= SEQUENCE {
|
|
ntcTsAnlyPidPid Unsigned32,
|
|
ntcTsAnlyPidType INTEGER,
|
|
ntcTsAnlyPidPIDRate Unsigned32,
|
|
ntcTsAnlyPidContinuityError INTEGER,
|
|
ntcTsAnlyPidTransportError INTEGER,
|
|
ntcTsAnlyPidCtuCntErrorCntr Counter64
|
|
}
|
|
|
|
ntcTsAnlyPidPid OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..8190)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PID"
|
|
::= { ntcTsAnlyPidEntry 1 }
|
|
|
|
ntcTsAnlyPidType OBJECT-TYPE
|
|
SYNTAX INTEGER { others(0), video(1), audio(2), privateSection(3), pesPrivate(4), mheg(5), dsmCc(6), h2221(7), mpe(8), auxiliary(9), slOrFlexMux(10), sdp(11), metadata(12), ipmp(13), userPrivate(14), pat(15), cat(16), tsdt(17), nitOrSt(18), sdtOrBatOrSt(19), eitOrStCit(20), rstOrSt(21), tdtOrTotOrSt(22), netwSync(23), rnt(24), inband(25), measurement(26), dit(27), sit(28), null(29), othersOrGhost(30), pmt(31), visual(32), srm(33), ecm(34), emm(35) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PID Type"
|
|
::= { ntcTsAnlyPidEntry 2 }
|
|
|
|
ntcTsAnlyPidPIDRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "bps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PID Rate for a specific stream."
|
|
::= { ntcTsAnlyPidEntry 3 }
|
|
|
|
ntcTsAnlyPidContinuityError OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Continuity Count Error"
|
|
::= { ntcTsAnlyPidEntry 4 }
|
|
|
|
ntcTsAnlyPidTransportError OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transport Error"
|
|
::= { ntcTsAnlyPidEntry 5 }
|
|
|
|
ntcTsAnlyPidCtuCntErrorCntr OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of packets with a continuity count error."
|
|
::= { ntcTsAnlyPidEntry 6 }
|
|
|
|
ntcTsAnlyPcrPidTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NtcTsAnlyPcrPidEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of PCR PID's with detailled time measurements."
|
|
::= { ntcTsAnlyObjects 5 }
|
|
|
|
ntcTsAnlyPcrPidEntry OBJECT-TYPE
|
|
SYNTAX NtcTsAnlyPcrPidEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row of the ntcTsAnlyPcrPidTable."
|
|
INDEX { ntcTsAnlyPcrPidPid }
|
|
::= { ntcTsAnlyPcrPidTable 1 }
|
|
|
|
NtcTsAnlyPcrPidEntry ::= SEQUENCE {
|
|
ntcTsAnlyPcrPidPid Unsigned32,
|
|
ntcTsAnlyPcrPidPcrIntervalTime Unsigned32,
|
|
ntcTsAnlyPcrPidPcrRepeatError INTEGER,
|
|
ntcTsAnlyPcrPidPcrAccuracyError INTEGER,
|
|
ntcTsAnlyPcrPidMinJitter Integer32,
|
|
ntcTsAnlyPcrPidMaxJitter Integer32,
|
|
ntcTsAnlyPcrPidMinHoldJitter Integer32,
|
|
ntcTsAnlyPcrPidMaxHoldJitter Integer32,
|
|
ntcTsAnlyPcrPidRateOffset Unsigned32,
|
|
ntcTsAnlyPcrPidPcrRate Unsigned32
|
|
}
|
|
|
|
ntcTsAnlyPcrPidPid OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..8190)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PID"
|
|
::= { ntcTsAnlyPcrPidEntry 1 }
|
|
|
|
ntcTsAnlyPcrPidPcrIntervalTime OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..9999999)
|
|
UNITS "ms"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Measured interval time (in milliseconds) between 2 PCR packets."
|
|
::= { ntcTsAnlyPcrPidEntry 2 }
|
|
|
|
ntcTsAnlyPcrPidPcrRepeatError OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PCR Repetition Error is raised when the spacing between two consecutive PCR
|
|
values is more than 40ms. The condition can occur when PCR packets get lost or
|
|
when PCR packets are not present at a sufficient rate."
|
|
::= { ntcTsAnlyPcrPidEntry 3 }
|
|
|
|
ntcTsAnlyPcrPidPcrAccuracyError OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PCR Accuracy error is raised when the PCR accuracy exceeds +/- 500nsec.
|
|
The definition of the alarm is taken from TR101290."
|
|
::= { ntcTsAnlyPcrPidEntry 4 }
|
|
|
|
ntcTsAnlyPcrPidMinJitter OBJECT-TYPE
|
|
SYNTAX Integer32 (-9999999..9999999)
|
|
UNITS "ns"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of PCR_AC (nanoseconds) over the last second."
|
|
::= { ntcTsAnlyPcrPidEntry 5 }
|
|
|
|
ntcTsAnlyPcrPidMaxJitter OBJECT-TYPE
|
|
SYNTAX Integer32 (-9999999..9999999)
|
|
UNITS "ns"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Max Jitter PCR_AC (nanoseconds) measured over the last second."
|
|
::= { ntcTsAnlyPcrPidEntry 6 }
|
|
|
|
ntcTsAnlyPcrPidMinHoldJitter OBJECT-TYPE
|
|
SYNTAX Integer32 (-9999999..9999999)
|
|
UNITS "ns"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum measured PCR_AC value (in nanoseconds) computed since the last
|
|
reset."
|
|
::= { ntcTsAnlyPcrPidEntry 7 }
|
|
|
|
ntcTsAnlyPcrPidMaxHoldJitter OBJECT-TYPE
|
|
SYNTAX Integer32 (-9999999..9999999)
|
|
UNITS "ns"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum measured PCR_AC value (in nanoseconds) computed since the last
|
|
reset."
|
|
::= { ntcTsAnlyPcrPidEntry 8 }
|
|
|
|
ntcTsAnlyPcrPidRateOffset OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "ppm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Rate Offset in PPM of the inband clock companed to the local clock. (ASI:
|
|
local clock, TS over IP: configured bitrate)"
|
|
::= { ntcTsAnlyPcrPidEntry 9 }
|
|
|
|
ntcTsAnlyPcrPidPcrRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "bps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PCR Rate (Mb/s) calculated by using the inband PCR timing information."
|
|
::= { ntcTsAnlyPcrPidEntry 10 }
|
|
|
|
ntcTsAnlyAlmSyncLoss OBJECT-TYPE
|
|
SYNTAX NtcAlarmState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm indicating that the synchronization with the Transport-Stream (TS) has
|
|
been lost. This conditions occurs when 2 or more consecutive corrupted SYNC
|
|
bytes are received. This variable indicates the current status of the alarm."
|
|
::= { ntcTsAnlyAlarm 1 }
|
|
|
|
ntcTsAnlyAlmSyncByte OBJECT-TYPE
|
|
SYNTAX NtcAlarmState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised when a single corrupted SYNC byte is detected and cleared
|
|
when the next correct one appears. This variable indicates the current status
|
|
of the alarm."
|
|
::= { ntcTsAnlyAlarm 2 }
|
|
|
|
ntcTsAnlyAlmPat OBJECT-TYPE
|
|
SYNTAX NtcAlarmState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm indicates that the 'Program Association Table' (PAT) can not be
|
|
detected properly in the stream. The PAT table id (0x00) should be detected in
|
|
a PID 0x0000 at least every 0.5 s. This variable indicates the current status
|
|
of the alarm."
|
|
::= { ntcTsAnlyAlarm 3 }
|
|
|
|
ntcTsAnlyAlmContinuityCount OBJECT-TYPE
|
|
SYNTAX NtcAlarmState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised when packets arrive out of sequence, get dropped or occur
|
|
more than once. This variable indicates the current status of the alarm."
|
|
::= { ntcTsAnlyAlarm 4 }
|
|
|
|
ntcTsAnlyAlmTransport OBJECT-TYPE
|
|
SYNTAX NtcAlarmState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm condition is detected when the 'Transport Error indicator'-bit in
|
|
the TS-Header is set to '1' for a specific PID. The alarm condition is cleared
|
|
when no Transport Error indication is detected for 5 sec. This variable
|
|
indicates the current status of the alarm."
|
|
::= { ntcTsAnlyAlarm 5 }
|
|
|
|
ntcTsAnlyAlmPcrRepetition OBJECT-TYPE
|
|
SYNTAX NtcAlarmState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm is raised if the spacing between two consecutive PCR values is more
|
|
than 40ms. The condition can occur when PCR packets get lost or when PCR
|
|
packets are not present at a sufficient rate. This variable indicates the
|
|
current status of the alarm."
|
|
::= { ntcTsAnlyAlarm 6 }
|
|
|
|
ntcTsAnlyAlmPcrDiscontinuity OBJECT-TYPE
|
|
SYNTAX NtcAlarmState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm indicates that the difference between two consecutive PCR values
|
|
exceeds the range [0-100] ms, while the 'discontinuity indicator' bit is not
|
|
set. This bit in the Adaptation Field should trigger a reset of the PCR
|
|
evaluation functionality. This variable indicates the current status of the
|
|
alarm."
|
|
::= { ntcTsAnlyAlarm 7 }
|
|
|
|
ntcTsAnlyAlmPcrAccuracy OBJECT-TYPE
|
|
SYNTAX NtcAlarmState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This alarm condition occurs when the PCR accuracy exceeds +/- 500nsec. The
|
|
definition of the alarm is taken from TR101290. This variable indicates the
|
|
current status of the alarm."
|
|
::= { ntcTsAnlyAlarm 8 }
|
|
|
|
ntcTsAnlyEPidTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NtcTsAnlyEPidEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table which contains PIDs on which an error has been detected."
|
|
::= { ntcTsAnlyObjects 7 }
|
|
|
|
ntcTsAnlyEPidEntry OBJECT-TYPE
|
|
SYNTAX NtcTsAnlyEPidEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row of the ntcTsAnlyEPidTable."
|
|
INDEX { ntcTsAnlyEPidPid }
|
|
::= { ntcTsAnlyEPidTable 1 }
|
|
|
|
NtcTsAnlyEPidEntry ::= SEQUENCE {
|
|
ntcTsAnlyEPidPid Unsigned32,
|
|
ntcTsAnlyEPidType INTEGER,
|
|
ntcTsAnlyEPidCtuCntErrorCntr Counter64,
|
|
ntcTsAnlyEPidContinuityError INTEGER,
|
|
ntcTsAnlyEPidTransportError INTEGER
|
|
}
|
|
|
|
ntcTsAnlyEPidPid OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..8190)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PID"
|
|
::= { ntcTsAnlyEPidEntry 1 }
|
|
|
|
ntcTsAnlyEPidType OBJECT-TYPE
|
|
SYNTAX INTEGER { others(0), video(1), audio(2), privateSection(3), pesPrivate(4), mheg(5), dsmCc(6), h2221(7), mpe(8), auxiliary(9), slOrFlexMux(10), sdp(11), metadata(12), ipmp(13), userPrivate(14), pat(15), cat(16), tsdt(17), nitOrSt(18), sdtOrBatOrSt(19), eitOrStCit(20), rstOrSt(21), tdtOrTotOrSt(22), netwSync(23), rnt(24), inband(25), measurement(26), dit(27), sit(28), null(29), othersOrGhost(30), pmt(31), visual(32), srm(33), ecm(34), emm(35) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PID Type"
|
|
::= { ntcTsAnlyEPidEntry 2 }
|
|
|
|
ntcTsAnlyEPidCtuCntErrorCntr OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the number of packets with a continuity count error."
|
|
::= { ntcTsAnlyEPidEntry 3 }
|
|
|
|
ntcTsAnlyEPidContinuityError OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Continuity Count Error"
|
|
::= { ntcTsAnlyEPidEntry 4 }
|
|
|
|
ntcTsAnlyEPidTransportError OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transport Error"
|
|
::= { ntcTsAnlyEPidEntry 5 }
|
|
|
|
|
|
--
|
|
-- Module Conformance
|
|
--
|
|
|
|
ntcTsAnlyConfGrpV1Standard OBJECT-GROUP
|
|
OBJECTS {
|
|
ntcTsAnlyEble,
|
|
ntcTsAnlyReset,
|
|
ntcTsAnlyEstimatedTsRate,
|
|
ntcTsAnlyPidType,
|
|
ntcTsAnlyPidPIDRate,
|
|
ntcTsAnlyPidContinuityError,
|
|
ntcTsAnlyPidTransportError,
|
|
ntcTsAnlyPidCtuCntErrorCntr,
|
|
ntcTsAnlyPcrPidPcrIntervalTime,
|
|
ntcTsAnlyPcrPidPcrRepeatError,
|
|
ntcTsAnlyPcrPidPcrAccuracyError,
|
|
ntcTsAnlyPcrPidMinJitter,
|
|
ntcTsAnlyPcrPidMaxJitter,
|
|
ntcTsAnlyPcrPidMinHoldJitter,
|
|
ntcTsAnlyPcrPidMaxHoldJitter,
|
|
ntcTsAnlyPcrPidRateOffset,
|
|
ntcTsAnlyPcrPidPcrRate,
|
|
ntcTsAnlyAlmSyncLoss,
|
|
ntcTsAnlyAlmSyncByte,
|
|
ntcTsAnlyAlmPat,
|
|
ntcTsAnlyAlmContinuityCount,
|
|
ntcTsAnlyAlmTransport,
|
|
ntcTsAnlyAlmPcrRepetition,
|
|
ntcTsAnlyAlmPcrDiscontinuity,
|
|
ntcTsAnlyAlmPcrAccuracy,
|
|
ntcTsAnlyEPidType,
|
|
ntcTsAnlyEPidCtuCntErrorCntr,
|
|
ntcTsAnlyEPidContinuityError,
|
|
ntcTsAnlyEPidTransportError
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Managed objects that constitute version 1 of a system device with standard capabilities."
|
|
::= { ntcTsAnlyConfGroup 1}
|
|
|
|
ntcTsAnlyConfCompV1Standard MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Compliance statement for Newtec device MIB implementations."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS
|
|
{
|
|
ntcTsAnlyConfGrpV1Standard
|
|
}
|
|
::= { ntcTsAnlyConfCompliance 1 }
|
|
|
|
|
|
END
|