-- EKINOPS-PmMC.TXT: MIB
|
||
--
|
||
--MIB Part Number:3MI00120AJAD
|
||
--MIB Version:02
|
||
--
|
||
-- Copyright (c) 2016 by Ekinops
|
||
-- All rights reserved.
|
||
--
|
||
-- *****************************************************************
|
||
|
||
EKINOPS-PmMC-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
ekinops,
|
||
EkiState,
|
||
EkiOnOff,
|
||
EkiMode,
|
||
EkiProtocol,
|
||
EkiApiState,
|
||
EkiSynchroMode,
|
||
EkiMeasureType
|
||
FROM EKINOPS-MIB
|
||
MODULE-IDENTITY,
|
||
OBJECT-TYPE,
|
||
NOTIFICATION-TYPE,
|
||
Unsigned32,
|
||
Integer32,
|
||
Counter32,
|
||
IpAddress
|
||
FROM SNMPv2-SMI
|
||
TEXTUAL-CONVENTION,
|
||
DisplayString
|
||
FROM SNMPv2-TC;
|
||
|
||
modulePmMC MODULE-IDENTITY
|
||
LAST-UPDATED "201605230000Z"
|
||
ORGANIZATION "Ekinops"
|
||
CONTACT-INFO
|
||
"Ekinops
|
||
|
||
3, rue Blaise Pascal
|
||
F-22300 Lannion / FRANCE
|
||
|
||
Tel : +33 (0)2 96 05 00 30
|
||
Fax : +33 (0)2 96 48 62 39
|
||
|
||
E-mail: support@ekinops.net"
|
||
DESCRIPTION
|
||
"MIB for the Ekinops Pmmc hardware."
|
||
REVISION "200701100000Z"
|
||
DESCRIPTION
|
||
"Initial Version."
|
||
REVISION "200706290000Z"
|
||
DESCRIPTION
|
||
"°C changed to C"
|
||
REVISION "200708230000Z"
|
||
DESCRIPTION
|
||
"°Add Alarms Objects"
|
||
REVISION "200711210000Z"
|
||
DESCRIPTION
|
||
"°Add Config Object, Update Ekinops address, Helps on objects, Ports Labels"
|
||
REVISION "200904100000Z"
|
||
DESCRIPTION
|
||
"Cosmetics for mib compilers"
|
||
REVISION "200909180000Z"
|
||
DESCRIPTION
|
||
"CondType Parameters insertion"
|
||
REVISION "201002250000Z"
|
||
DESCRIPTION
|
||
"Probcause,AlarmType - NMS"
|
||
REVISION "201011040000Z"
|
||
DESCRIPTION
|
||
"Formulas and Event on XFP init"
|
||
REVISION "201012170000Z"
|
||
DESCRIPTION
|
||
"Fix on Smpc trap"
|
||
REVISION "201207040000Z"
|
||
DESCRIPTION
|
||
"Minor cosmetic updates"
|
||
REVISION "201403260000Z"
|
||
DESCRIPTION
|
||
"Probcause,AlarmType - NMS completion"
|
||
REVISION "201412110000Z"
|
||
DESCRIPTION
|
||
"Labels cosmetic updates"
|
||
REVISION "201605230000Z"
|
||
DESCRIPTION
|
||
"New AlarmType – synthesisAlarm (12)"
|
||
::= { ekinops 21 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF LEVEL 2
|
||
--- *****************************************************
|
||
|
||
|
||
pmmcalarms OBJECT IDENTIFIER ::= { modulePmMC 2 }
|
||
pmmcAlmOther OBJECT IDENTIFIER ::= { pmmcalarms 1 }
|
||
pmmcAlmOtherNurg OBJECT IDENTIFIER ::= { pmmcAlmOther 1 }
|
||
pmmcAlmOtherUrg OBJECT IDENTIFIER ::= { pmmcAlmOther 2 }
|
||
pmmcAlmOtherCrit OBJECT IDENTIFIER ::= { pmmcAlmOther 3 }
|
||
|
||
pmmcAlmClient OBJECT IDENTIFIER ::= { pmmcalarms 2 }
|
||
pmmcAlmClientNurg OBJECT IDENTIFIER ::= { pmmcAlmClient 1 }
|
||
pmmcAlmClientUrg OBJECT IDENTIFIER ::= { pmmcAlmClient 2 }
|
||
pmmcAlmClientCrit OBJECT IDENTIFIER ::= { pmmcAlmClient 3 }
|
||
|
||
pmmcAlmLine OBJECT IDENTIFIER ::= { pmmcalarms 3 }
|
||
pmmcAlmLineNurg OBJECT IDENTIFIER ::= { pmmcAlmLine 1 }
|
||
pmmcAlmLineUrg OBJECT IDENTIFIER ::= { pmmcAlmLine 2 }
|
||
pmmcAlmLineCrit OBJECT IDENTIFIER ::= { pmmcAlmLine 3 }
|
||
|
||
|
||
pmmcmeasures OBJECT IDENTIFIER ::= { modulePmMC 3 }
|
||
pmmcMesrOther OBJECT IDENTIFIER ::= { pmmcmeasures 1 }
|
||
pmmcMesrClient OBJECT IDENTIFIER ::= { pmmcmeasures 2 }
|
||
pmmcMesrLine OBJECT IDENTIFIER ::= { pmmcmeasures 3 }
|
||
|
||
|
||
pmmccontrolsWrite OBJECT IDENTIFIER ::= { modulePmMC 6 }
|
||
pmmcCtrlOther OBJECT IDENTIFIER ::= { pmmccontrolsWrite 1 }
|
||
pmmcCtrlClient OBJECT IDENTIFIER ::= { pmmccontrolsWrite 2 }
|
||
pmmcCtrlLine OBJECT IDENTIFIER ::= { pmmccontrolsWrite 3 }
|
||
|
||
pmmcri OBJECT IDENTIFIER ::= { modulePmMC 7 }
|
||
|
||
|
||
pmmcConfig OBJECT IDENTIFIER ::= { modulePmMC 9 }
|
||
|
||
pmmctraps OBJECT IDENTIFIER ::= { modulePmMC 10 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- TEXTUAL-CONVENTION
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
PmmcBitRate ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "different rates for a client and line ports"
|
||
SYNTAX INTEGER {
|
||
rateSTM16OC48(0),
|
||
rate1GBE(1),
|
||
rateSTM4OC12(2),
|
||
rateSTM1OC3(3),
|
||
rate2GFC(4),
|
||
rate1GFC(5),
|
||
rateFastEthernet(7),
|
||
rateSTM16FEC(8),
|
||
rateSTM4FEC(9),
|
||
rateSTM1FEC(10)
|
||
}
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- REMOTE INVENTORY
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
pmmcRinvReloadInventory OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reload the inventory: This OID triggers an
|
||
inventory reload."
|
||
::= { pmmcri 2 }
|
||
|
||
|
||
pmmcRinvHwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Module platform description: This OID contains the
|
||
description of the Module."
|
||
::= { pmmcri 4 }
|
||
|
||
pmmcRinvSwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SW platform description: This OID contains the
|
||
description of the Software platform."
|
||
::= { pmmcri 5 }
|
||
|
||
pmmcRinvLine1SFP OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the SFP: This OID contains the inventory for the Port A SFP"
|
||
::= { pmmcri 6 }
|
||
|
||
|
||
pmmcRinvLine2SFP OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the SFP: This OID contains the inventory for the Port B SFP"
|
||
::= { pmmcri 7 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- ALARMS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm0 article
|
||
--- *****************************************************
|
||
pmmcAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmmcAlmOtherCrit 0 }
|
||
|
||
|
||
|
||
|
||
pmmcAlmDefFuseB OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse B Fail :This OID indicates
|
||
that the fuse of the power input
|
||
B is in fail condition <Help>
|
||
Status of the Fuse B <Condtype>
|
||
DEF_FUSE_B <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm0 16 }
|
||
|
||
|
||
|
||
pmmcAlmDefFuseA OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse A Fail :This OID indicates
|
||
that the fuse of the power input
|
||
A is in fail condition <Help>
|
||
Status of the Fuse A <Condtype>
|
||
DEF_FUSE_A <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm0 15 }
|
||
|
||
|
||
|
||
pmmcAlmSynUnlock OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Synthesizer Not Locked :This OID
|
||
indicates that the frequency synthesizer
|
||
is not locked. <Help> This status
|
||
indicates if the clock synthesizer
|
||
is locked. <Condtype> SYN_UNLOCK
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm0 14 }
|
||
|
||
|
||
|
||
pmmcAlmModuleGlobFailure OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Failure :This OID is set
|
||
on detection of a failure originating
|
||
from the PM <Condtype> MODULE_GLOB_FAILURE
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm0 9 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm7 article
|
||
--- *****************************************************
|
||
pmmcAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmmcAlmLineCrit 7 }
|
||
|
||
|
||
|
||
|
||
pmmcAlmLine2Fail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 Failure :This OID indicates
|
||
a failure on the Line 2 <Condtype>
|
||
LINE2_FAIL <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm7 12 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TrscvDdmAlm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Alarm DDM On Optical Module 2
|
||
:This OID indicates an alarm is
|
||
present coming out of optical interface
|
||
DDM on Line 2 <Help> This alarm
|
||
indicates if a DDM Alarm has been
|
||
detected on the line 2 transceiver
|
||
<Condtype> LINE2_TRSCV_DDM_ALM
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm7 10 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TrscvDdmWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warning DDM On Optical Module
|
||
2 :This OID indicates a warning
|
||
is present coming out of optical
|
||
interface DDM on Line 2 <Help>
|
||
This alarm indicates if a DDM
|
||
Warning has been detected on the
|
||
line 2 transceiver <Condtype> LINE2_TRSCV_DDM_WARNING
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm7 9 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TrscvLsd OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 SFP Laser Shutdown :This
|
||
OID indicates the optical output
|
||
power is off on Line 2 <Help>
|
||
This status indicates if the
|
||
line 2 transceiver laser is ON
|
||
or OFF <Condtype> LINE2_TRSCV_LSD
|
||
<Probcause> other (1) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm7 5 }
|
||
|
||
|
||
|
||
pmmcAlmLine2HwFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 HW Failure :This OID indicates
|
||
a hardware failure on the Line
|
||
2 <Condtype> LINE2_HW_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmmcAlmsynthAlm7 4 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TrscvDdmAbsent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
DDM Supported On Line 2 SFP :This
|
||
OID indicates that the transceiver
|
||
module 2 does not support Digital
|
||
Diagnostic Monitoring Functions
|
||
<Help> This status indicates
|
||
if the line 2 transceiver includes
|
||
the DDM feature <Condtype> LINE2_TRSCV_DDM_ABSENT
|
||
<Probcause> informationalStatus(1000)
|
||
<Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmmcAlmsynthAlm7 2 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TrscvAbsent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 SFP Absent :This OID indicates
|
||
that the transceiver module 2 is
|
||
not present. <Help> This alarm
|
||
indicates if the line 2 transceiver
|
||
is present. <Condtype> LINE2_TRSCV_ABSENT
|
||
<Probcause> inputOutputDeviceError
|
||
(24) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2) <Event> ObjectCDINV
|
||
"
|
||
::= { pmmcAlmsynthAlm7 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm8 article
|
||
--- *****************************************************
|
||
pmmcAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmmcAlmClientCrit 8 }
|
||
|
||
|
||
|
||
|
||
pmmcAlmLine1Fail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 Failure :This OID indicates
|
||
a failure on the Line 1 <Condtype>
|
||
LINE1_FAIL <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm8 12 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TrscvDdmAlm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Alarm DDM On Optical Module 1
|
||
:This OID indicates an alarm is
|
||
present coming out of optical interface
|
||
DDM on Line 1 <Help> This alarm
|
||
indicates if a DDM Alarm has been
|
||
detected on the line 1 transceiver
|
||
<Condtype> LINE1_TRSCV_DDM_ALM
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm8 10 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TrscvDdmWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warning DDM On Optical Module
|
||
1 :This OID indicates a warning
|
||
is present coming out of optical
|
||
interface DDM on Line 1 <Help>
|
||
This alarm indicates if a DDM
|
||
Warning has been detected on the
|
||
line 1 transceiver <Condtype> LINE1_TRSCV_DDM_WARNING
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm8 9 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TrscvLsd OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 SFP Laser Shutdown :This
|
||
OID indicates the optical output
|
||
power is off on Line 1 <Help>
|
||
This status indicates if the
|
||
line 1 transceiver laser is ON
|
||
or OFF <Condtype> LINE1_TRSCV_LSD
|
||
<Probcause> other (1) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmsynthAlm8 5 }
|
||
|
||
|
||
|
||
pmmcAlmLine1HwFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 HW Failure :This OID indicates
|
||
a hardware failure on the Line
|
||
1 <Condtype> LINE1_HW_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmmcAlmsynthAlm8 4 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TrscvDdmAbsent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
DDM Supported On Line 1 SFP :This
|
||
OID indicates that the transceiver
|
||
module 1 does not support Digital
|
||
Diagnostic Monitoring Functions
|
||
<Help> This status indicates
|
||
if the line 1 transceiver includes
|
||
the DDM feature <Condtype> LINE1_TRSCV_DDM_ABSENT
|
||
<Probcause> informationalStatus(1000)
|
||
<Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmmcAlmsynthAlm8 2 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TrscvAbsent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 SFP Absent :This OID indicates
|
||
that the transceiver module 2 is
|
||
not present. <Help> This alarm
|
||
indicates if the line 1 transceiver
|
||
is present. <Condtype> LINE1_TRSCV_ABSENT
|
||
<Probcause> inputOutputDeviceError
|
||
(24) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2) <Event> ObjectCDINV
|
||
"
|
||
::= { pmmcAlmsynthAlm8 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line1AccessioAlm article
|
||
--- *****************************************************
|
||
pmmcAlmline1AccessioAlm OBJECT IDENTIFIER ::= { pmmcAlmClientCrit 16 }
|
||
|
||
|
||
|
||
|
||
pmmcAlmLine1Los OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Loss Of Optical Signal On Line
|
||
1 :This OID indicates that no signal
|
||
is present on the transceiver 1
|
||
<Help> This alarm indicates if
|
||
an optical signal is detected on
|
||
the line 1 transceiver input <Condtype>
|
||
LINE1_LOS <Probcause> receiveFailure
|
||
(41) <Alarmtype> physicalViolation
|
||
(9) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1AccessioAlm 4 }
|
||
|
||
|
||
|
||
pmmcAlmLine1LasFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 SFP Tx Failed :This OID
|
||
indicates that the transmitter
|
||
fails for the transceiver plugged
|
||
into the Line 1 (this alarm reports
|
||
the transmitter failure alarm generated
|
||
by the transceivers) <Help> This
|
||
alarm indicates if the laser of
|
||
the Line 1 transceiver is in fail
|
||
condition <Condtype> LINE1_LAS_FAIL
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1AccessioAlm 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line1TrscvAlmDdm article
|
||
--- *****************************************************
|
||
pmmcAlmline1TrscvAlmDdm OBJECT IDENTIFIER ::= { pmmcAlmClientUrg 18 }
|
||
|
||
|
||
|
||
|
||
pmmcAlmLine1RxPwrHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Rx Power High :Alarm indicating
|
||
that the transceiver input power
|
||
of Line 1 is higher than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE1_RX_PWR_HIGH_ALA
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvAlmDdm 16 }
|
||
|
||
|
||
|
||
pmmcAlmLine1RxPwrLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Rx Power Low :Alarm indicating
|
||
that the transceiver input power
|
||
of Line 1 is lower than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE1_RX_PWR_LOW_ALA
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvAlmDdm 15 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TempHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Temp High :Alarm indicating
|
||
that the transceiver temperature
|
||
of Line 1 is higher than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE1_TEMP_HIGH_ALA
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvAlmDdm 8 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TempLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Temp Low :Alarm indicating
|
||
that the transceiver temperature
|
||
of Line 1 is lower than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE1_TEMP_LOW_ALA
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvAlmDdm 7 }
|
||
|
||
|
||
|
||
pmmcAlmLine1VccHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Power Supply High :Alarm
|
||
indicating that the transceiver
|
||
power supply of Line 1 is higher
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE1_VCC_HIGH_ALA <Probcause>
|
||
powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmmcAlmline1TrscvAlmDdm 6 }
|
||
|
||
|
||
|
||
pmmcAlmLine1VccLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Power Supply Low :Alarm
|
||
indicating that the transceiver
|
||
power supply of Line 1 is lower
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE1_VCC_LOW_ALA <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvAlmDdm 5 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TxBiasHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Bias High :Alarm indicating
|
||
that the transceiver laser bias
|
||
current of Line 1 is higher than
|
||
the threshold value written in
|
||
the transceiver EEPROM <Condtype>
|
||
LINE1_TX_BIAS_HIGH_ALA <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvAlmDdm 4 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TxBiasLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Bias Low :Alarm indicating
|
||
that the transceiver laser bias
|
||
current of Line 1 is lower than
|
||
the threshold value written in
|
||
the transceiver EEPROM <Condtype>
|
||
LINE1_TX_BIAS_LOW_ALA <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvAlmDdm 3 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TxPwrHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Tx Power High :Alarm indicating
|
||
that the transceiver output power
|
||
of Line 1 is higher than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE1_TX_PWR_HIGH_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvAlmDdm 2 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TxPwrLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Tx Power Low :Alarm indicating
|
||
that the transceiver output power
|
||
of Line 1 is lower than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE1_TX_PWR_LOW_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvAlmDdm 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line1TrscvWarnDdm article
|
||
--- *****************************************************
|
||
pmmcAlmline1TrscvWarnDdm OBJECT IDENTIFIER ::= { pmmcAlmClientNurg 20 }
|
||
|
||
|
||
|
||
|
||
pmmcAlmLine1RxPwrHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Rx Power High Warning
|
||
:Warning indicating that the transceiver
|
||
input power of Line 1 is higher
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE1_RX_PWR_HIGH_WNG <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvWarnDdm 16 }
|
||
|
||
|
||
|
||
pmmcAlmLine1RxPwrLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Rx Power Low Warning :Warning
|
||
indicating that the transceiver
|
||
input power of Line 1 is lower
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE1_RX_PWR_LOW_WNG <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvWarnDdm 15 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TempHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Temp High Warning :Warning
|
||
indicating that the transceiver
|
||
temperature of Line 1 is higher
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE1_TEMP_HIGH_WNG <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvWarnDdm 8 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TempLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Temp Low Warning :Warning
|
||
indicating that the transceiver
|
||
temperature of Line 1 is lower
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE1_TEMP_LOW_WNG <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvWarnDdm 7 }
|
||
|
||
|
||
|
||
pmmcAlmLine1VccHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Power Supply High Warning
|
||
:Warning indicating that the transceiver
|
||
power supply of Line 1 is higher
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE1_VCC_HIGH_WNG <Probcause>
|
||
powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmmcAlmline1TrscvWarnDdm 6 }
|
||
|
||
|
||
|
||
pmmcAlmLine1VccLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Power Supply Low Warning
|
||
:Warning indicating that the transceiver
|
||
power supply of Line 1 is lower
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE1_VCC_LOW_WNG <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvWarnDdm 5 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TxBiasHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Bias High Warning :Warning
|
||
indicating that the transceiver
|
||
laser bias current of Line 1 is
|
||
higher than the threshold value
|
||
written in the transceiver EEPROM
|
||
<Condtype> LINE1_TX_BIAS_HIGH_WNG
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvWarnDdm 4 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TxBiasLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Bias Low Warning :Warning
|
||
indicating that the transceiver
|
||
laser bias current of Line 1 is
|
||
lower than the threshold value
|
||
written in the transceiver EEPROM
|
||
<Condtype> LINE1_TX_BIAS_LOW_WNG
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvWarnDdm 3 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TxPwrHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Tx Power High Warning
|
||
:Warning indicating that the transceiver
|
||
output power of Line 1 is higher
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE1_TX_PWR_HIGH_WNG <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvWarnDdm 2 }
|
||
|
||
|
||
|
||
pmmcAlmLine1TxPwLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 1 Tx Power Low Warning :Warning
|
||
indicating that the transceiver
|
||
output power of Line 1 is lower
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE1_TX_PW_LOW_WNG <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1TrscvWarnDdm 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line1CdrAlm article
|
||
--- *****************************************************
|
||
pmmcAlmline1CdrAlm OBJECT IDENTIFIER ::= { pmmcAlmClientNurg 23 }
|
||
|
||
|
||
|
||
|
||
pmmcAlmLine1CdrRefAbsent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 CDR Reference Clock Absent
|
||
:This OID indicates that the CDR
|
||
reference clock is absent on Line
|
||
1 <Help> This alarm indicates
|
||
if the reference clock is present
|
||
on the line 1 CDR <Condtype> LINE1_CDR_REF_ABSENT
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1CdrAlm 3 }
|
||
|
||
|
||
|
||
pmmcAlmLine1CdrLossoflock OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 CDR Loss Of Lock :This
|
||
OID indicates that the Line 1
|
||
CDR is not locked <Help> This
|
||
alarm indicates if Line 1 CDR is
|
||
correclty locked on the input signal
|
||
<Condtype> LINE1_CDR_LOSSOFLOCK
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1CdrAlm 2 }
|
||
|
||
|
||
|
||
pmmcAlmLine1CdrLossofsignal OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 CDR Loss Of Signal :This
|
||
OID indicates that a Loss of electrical
|
||
signal is detected on the Line
|
||
1 CDR <Help> This alarm indicates
|
||
if an electrical signal is detected
|
||
on the line 1 CDR <Condtype> LINE1_CDR_LOSSOFSIGNAL
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline1CdrAlm 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line2AccessioAlm article
|
||
--- *****************************************************
|
||
pmmcAlmline2AccessioAlm OBJECT IDENTIFIER ::= { pmmcAlmLineCrit 24 }
|
||
|
||
|
||
|
||
|
||
pmmcAlmLine2Los OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Loss Of Optical Signal On Line
|
||
2 :This OID indicates that no signal
|
||
is present on the transceiver 2
|
||
<Help> This alarm indicates if
|
||
an optical signal is detected on
|
||
the line 2 transceiver input <Condtype>
|
||
LINE2_LOS <Probcause> receiveFailure
|
||
(41) <Alarmtype> physicalViolation
|
||
(9) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2AccessioAlm 4 }
|
||
|
||
|
||
|
||
pmmcAlmLine2LasFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 SFP Tx Failed :This OID
|
||
indicates that the transmitter
|
||
fails for the transceiver plugged
|
||
into the Line 1 (this alarm reports
|
||
the transmitter failure alarm generated
|
||
by the transceivers) <Help> This
|
||
alarm indicates if the laser of
|
||
the line 2 transceiver is in fail
|
||
condition <Condtype> LINE2_LAS_FAIL
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2AccessioAlm 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line2TrscvAlmDdm article
|
||
--- *****************************************************
|
||
pmmcAlmline2TrscvAlmDdm OBJECT IDENTIFIER ::= { pmmcAlmLineUrg 26 }
|
||
|
||
|
||
|
||
|
||
pmmcAlmLine2RxPwrHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Rx Power High :Alarm indicating
|
||
that the transceiver input power
|
||
of Line 2 is higher than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE2_RX_PWR_HIGH_ALA
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvAlmDdm 16 }
|
||
|
||
|
||
|
||
pmmcAlmLine2RxPwrLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Rx Power Low :Alarm indicating
|
||
that the transceiver input power
|
||
of Line 2 is lower than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE2_RX_PWR_LOW_ALA
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvAlmDdm 15 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TempHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Temp High :Alarm indicating
|
||
that the transceiver temperature
|
||
of Line 2 is higher than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE2_TEMP_HIGH_ALA
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvAlmDdm 8 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TempLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Temp Low :Alarm indicating
|
||
that the transceiver temperature
|
||
of Line 2 is lower than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE2_TEMP_LOW_ALA
|
||
<Probcause> temperatureUnacceptable
|
||
(51) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvAlmDdm 7 }
|
||
|
||
|
||
|
||
pmmcAlmLine2VccHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Power Supply High :Alarm
|
||
indicating that the transceiver
|
||
power supply of Line 2 is higher
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE2_VCC_HIGH_ALA <Probcause>
|
||
powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmmcAlmline2TrscvAlmDdm 6 }
|
||
|
||
|
||
|
||
pmmcAlmLine2VccLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Power Supply Low :Alarm
|
||
indicating that the transceiver
|
||
power supply of Line 2 is lower
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE2_VCC_LOW_ALA <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvAlmDdm 5 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TxBiasHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Bias High :Alarm indicating
|
||
that the transceiver laser bias
|
||
current of Line 2 is higher than
|
||
the threshold value written in
|
||
the transceiver EEPROM <Condtype>
|
||
LINE2_TX_BIAS_HIGH_ALA <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvAlmDdm 4 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TxBiasLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Bias Low :Alarm indicating
|
||
that the transceiver laser bias
|
||
current of Line 2 is lower than
|
||
the threshold value written in
|
||
the transceiver EEPROM <Condtype>
|
||
LINE2_TX_BIAS_LOW_ALA <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvAlmDdm 3 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TxPwrHighAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Tx Power High :Alarm indicating
|
||
that the transceiver output power
|
||
of Line 2 is higher than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE2_TX_PWR_HIGH_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvAlmDdm 2 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TxPwrLowAla OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Tx Power Low :Alarm indicating
|
||
that the transceiver output power
|
||
of Line 2 is lower than the threshold
|
||
value written in the transceiver
|
||
EEPROM <Condtype> LINE2_TX_PWR_LOW_ALA
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvAlmDdm 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line2TrscvWarnDdm article
|
||
--- *****************************************************
|
||
pmmcAlmline2TrscvWarnDdm OBJECT IDENTIFIER ::= { pmmcAlmLineNurg 28 }
|
||
|
||
|
||
|
||
|
||
pmmcAlmLine2RxPwrHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Rx Power High Warning
|
||
:Warning indicating that the transceiver
|
||
input power of Line 2 is higher
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE2_RX_PWR_HIGH_WNG <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvWarnDdm 16 }
|
||
|
||
|
||
|
||
pmmcAlmLine2RxPwrLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Rx Power Low Warning :Warning
|
||
indicating that the transceiver
|
||
input power of Line 2 is lower
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE2_RX_PWR_LOW_WNG <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvWarnDdm 15 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TempHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Temp High Warning :Warning
|
||
indicating that the transceiver
|
||
temperature of Line 2 is higher
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE2_TEMP_HIGH_WNG <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvWarnDdm 8 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TempLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Temp Low Warning :Warning
|
||
indicating that the transceiver
|
||
temperature of Line 2 is lower
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE2_TEMP_LOW_WNG <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvWarnDdm 7 }
|
||
|
||
|
||
|
||
pmmcAlmLine2VccHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Power Supply High Warning
|
||
:Warning indicating that the transceiver
|
||
power supply of Line 2 is higher
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE2_VCC_HIGH_WNG <Probcause>
|
||
powerProblem (36) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmmcAlmline2TrscvWarnDdm 6 }
|
||
|
||
|
||
|
||
pmmcAlmLine2VccLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Power Supply Low Warning
|
||
:Warning indicating that the transceiver
|
||
power supply of Line 2 is lower
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE2_VCC_LOW_WNG <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvWarnDdm 5 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TxBiasHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Bias High Warning :Warning
|
||
indicating that the transceiver
|
||
laser bias current of Line 2 is
|
||
higher than the threshold value
|
||
written in the transceiver EEPROM
|
||
<Condtype> LINE2_TX_BIAS_HIGH_WNG
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvWarnDdm 4 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TxBiasLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Bias Low Warning :Warning
|
||
indicating that the transceiver
|
||
laser bias current of Line 2 is
|
||
lower than the threshold value
|
||
written in the transceiver EEPROM
|
||
<Condtype> LINE2_TX_BIAS_LOW_WNG
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvWarnDdm 3 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TxPwrHighWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Tx Power High Warning
|
||
:Warning indicating that the transceiver
|
||
output power of Line 2 is higher
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE2_TX_PWR_HIGH_WNG <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvWarnDdm 2 }
|
||
|
||
|
||
|
||
pmmcAlmLine2TxPwLowWng OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
TRSCV 2 Tx Power Low Warning :Warning
|
||
indicating that the transceiver
|
||
output power of Line 2 is lower
|
||
than the threshold value written
|
||
in the transceiver EEPROM <Condtype>
|
||
LINE2_TX_PW_LOW_WNG <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2TrscvWarnDdm 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line2CdrAlm article
|
||
--- *****************************************************
|
||
pmmcAlmline2CdrAlm OBJECT IDENTIFIER ::= { pmmcAlmLineNurg 31 }
|
||
|
||
|
||
|
||
|
||
pmmcAlmLine2CdrRefAbsent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 CDR Reference Clock Absent
|
||
:This OID indicates that the CDR
|
||
reference clock is absent on Line
|
||
2 <Help> This alarm indicates
|
||
if the reference clock is present
|
||
on the line 2 CDR <Condtype> LINE2_CDR_REF_ABSENT
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2CdrAlm 3 }
|
||
|
||
|
||
|
||
pmmcAlmLine2CdrLossoflock OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 CDR Loss Of Lock :This
|
||
OID indicates that the Line 2
|
||
CDR is not locked <Help> This
|
||
alarm indicates if Line 2 CDR is
|
||
correclty locked on the input signal
|
||
<Condtype> LINE2_CDR_LOSSOFLOCK
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2CdrAlm 2 }
|
||
|
||
|
||
|
||
pmmcAlmLine2CdrLossofsignal OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 CDR Loss Of Signal :This
|
||
OID indicates that a Loss of electrical
|
||
signal is detected on the Line
|
||
2 CDR <Help> This alarm indicates
|
||
if an electrical signal is detected
|
||
on the line 2 CDR <Condtype> LINE2_CDR_LOSSOFSIGNAL
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmmcAlmline2CdrAlm 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONTROLS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synth0 article
|
||
--- *****************************************************
|
||
pmmcCtrlsynth0 OBJECT IDENTIFIER ::= { pmmcCtrlOther 0 }
|
||
|
||
|
||
|
||
|
||
pmmcCtrlConfClear OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Clear Configuration Tables :This
|
||
bit clears the configuration tables
|
||
from configuration in the flash.
|
||
<Help> This control restores
|
||
the default configuration of the
|
||
module
|
||
"
|
||
::= { pmmcCtrlsynth0 13 }
|
||
|
||
|
||
|
||
pmmcCtrlConfFlash OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Write Configuration Tables :This
|
||
bit saves the current configuration
|
||
of the module as configuration
|
||
in the flash. <Help> This control
|
||
saves the customer configuration
|
||
on the module
|
||
"
|
||
::= { pmmcCtrlsynth0 9 }
|
||
|
||
|
||
|
||
pmmcCtrlConfLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Load Configuration Tables :When
|
||
set this enables loading from flash
|
||
configuration1 into the module.
|
||
"
|
||
::= { pmmcCtrlsynth0 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synth4 article
|
||
--- *****************************************************
|
||
pmmcCtrlsynth4 OBJECT IDENTIFIER ::= { pmmcCtrlOther 4 }
|
||
|
||
|
||
|
||
|
||
pmmcCtrlCorrelatOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Disable Alarm Correlation :This
|
||
OID disables the alarm correlation
|
||
in the PM.
|
||
"
|
||
::= { pmmcCtrlsynth4 2 }
|
||
|
||
|
||
|
||
pmmcCtrlCorrelatOn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Enable Alarm Correlation :This
|
||
OID enables the alarm correlation
|
||
in the PM.
|
||
"
|
||
::= { pmmcCtrlsynth4 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the swMgnt article
|
||
--- *****************************************************
|
||
pmmcCtrlswMgnt OBJECT IDENTIFIER ::= { pmmcCtrlOther 5 }
|
||
|
||
|
||
|
||
|
||
pmmcCtrlWarmReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Warm Reset :This OID, when
|
||
set, causes a warm reset of the
|
||
Software. This reset is not traffic
|
||
affecting, and the configuration
|
||
of the Sofwtare remains unchanged.
|
||
<Help> This control initiates
|
||
a warm reset of the module.
|
||
"
|
||
::= { pmmcCtrlswMgnt 3 }
|
||
|
||
|
||
|
||
pmmcCtrlColdReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Cold Reset :This OID, when
|
||
set, causes a cold reset of the
|
||
Software. This reset is traffic
|
||
affecting, and the configuration
|
||
of Software is reloaded on start-up.
|
||
<Help> This control initiates
|
||
a cold reset of the module.
|
||
"
|
||
::= { pmmcCtrlswMgnt 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line1TrscvOnoff article
|
||
--- *****************************************************
|
||
pmmcCtrlline1TrscvOnoff OBJECT IDENTIFIER ::= { pmmcCtrlClient 16 }
|
||
|
||
|
||
|
||
|
||
pmmcCtrlLine1TrscvOnoff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 SFP Laser Shutdown :This
|
||
OID switches off the transceiver
|
||
on Line 1 <Help> This control
|
||
defines the laser state of the
|
||
line 1 transceiver
|
||
"
|
||
::= { pmmcCtrlline1TrscvOnoff 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line2TrscvOnoff article
|
||
--- *****************************************************
|
||
pmmcCtrlline2TrscvOnoff OBJECT IDENTIFIER ::= { pmmcCtrlLine 24 }
|
||
|
||
|
||
|
||
|
||
pmmcCtrlLine2TrscvOnoff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 SFP Laser Shutdown :This
|
||
OID switches off the transceiver
|
||
on Line 2 <Help> This control
|
||
defines the laser state of the
|
||
line 2 transceiver
|
||
"
|
||
::= { pmmcCtrlline2TrscvOnoff 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the ledTest article
|
||
--- *****************************************************
|
||
pmmcCtrlledTest OBJECT IDENTIFIER ::= { pmmcCtrlOther 64 }
|
||
|
||
|
||
|
||
|
||
pmmcCtrlLedOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Leds Off :This OID switches off
|
||
all the Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to OFF
|
||
"
|
||
::= { pmmcCtrlledTest 3 }
|
||
|
||
|
||
|
||
pmmcCtrlRedLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Red Leds Test :This OID switches
|
||
on all the red Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to red
|
||
"
|
||
::= { pmmcCtrlledTest 2 }
|
||
|
||
|
||
|
||
pmmcCtrlGreenLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Green Leds Test :This OID switches
|
||
on all the green Leds as a test
|
||
feature. <Help> This control
|
||
initiates a test leds turning
|
||
all the LEDs to green
|
||
"
|
||
::= { pmmcCtrlledTest 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- MEASURES
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line1Temperature article
|
||
--- *****************************************************
|
||
|
||
pmmcMesrline1Temperature OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 SFP Temperature :This OID
|
||
gives the temperature of the transceiver
|
||
Line 1, read from the DDM (Digital
|
||
Diagnostic Monitoring) (Temperature
|
||
= AV/256) (Unit = C) <Help> This
|
||
measure gives the temperature of
|
||
the line 1 transceiver
|
||
"
|
||
::= { pmmcMesrClient 16 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line1Volt article
|
||
--- *****************************************************
|
||
|
||
pmmcMesrline1Volt OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 SFP Power Supply :This
|
||
OID gives the voltage of the transceiver
|
||
Line 1, read from the DDM (Digital
|
||
Diagnostic Monitoring) (Voltage
|
||
= AV/10000) (Unit = V) <Help>
|
||
This measure gives the 3V3 voltage
|
||
of the line 1 transceiver
|
||
"
|
||
::= { pmmcMesrClient 17 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line1TxBias article
|
||
--- *****************************************************
|
||
|
||
pmmcMesrline1TxBias OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 SFP Laser Bias :This OID
|
||
gives the bias value of the transceiver
|
||
Line 1, read from the DDM (Digital
|
||
Diagnostic Monitoring) (Bias =
|
||
AV/500) (Unit = mA) <Help> This
|
||
measure gives the bias of the line
|
||
1 transceiver
|
||
"
|
||
::= { pmmcMesrClient 18 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line1TxPower article
|
||
--- *****************************************************
|
||
|
||
pmmcMesrline1TxPower OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 SFP Tx Power :This OID
|
||
gives the transmit power value
|
||
of the transceiver Line 1, read
|
||
from the DDM (Digital Diagnostic
|
||
Monitoring) (Power = 10*log(AV)-40)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Tx optical power of the
|
||
line 1 transceiver
|
||
"
|
||
::= { pmmcMesrClient 19 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line1RxPower article
|
||
--- *****************************************************
|
||
|
||
pmmcMesrline1RxPower OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 1 SFP Rx Power :This OID
|
||
gives the receive power value
|
||
of the transceiver Line 1, read
|
||
from the DDM (Digital Diagnostic
|
||
Monitoring) (Power = 10*log(AV)-40)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Rx optical power of the
|
||
line 1 transceiver
|
||
"
|
||
::= { pmmcMesrClient 20 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line2Temperature article
|
||
--- *****************************************************
|
||
|
||
pmmcMesrline2Temperature OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 SFP Temperature :This OID
|
||
gives the temperature of the transceiver
|
||
Line 2, read from the DDM (Digital
|
||
Diagnostic Monitoring) (Temperature
|
||
= AV/256) (Unit = C) <Help> This
|
||
measure gives the temperature of
|
||
the line 2 transceiver
|
||
"
|
||
::= { pmmcMesrLine 24 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line2Volt article
|
||
--- *****************************************************
|
||
|
||
pmmcMesrline2Volt OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 SFP Power Supply :This
|
||
OID gives the voltage of the transceiver
|
||
Line 2, read from the DDM (Digital
|
||
Diagnostic Monitoring) (Voltage
|
||
= AV/10000) (Unit = V) <Help>
|
||
This measure gives the 3V3 voltage
|
||
of the line 2 transceiver
|
||
"
|
||
::= { pmmcMesrLine 25 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line2TxBias article
|
||
--- *****************************************************
|
||
|
||
pmmcMesrline2TxBias OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 SFP Laser Bias :This OID
|
||
gives the bias value of the transceiver
|
||
Line 2, read from the DDM (Digital
|
||
Diagnostic Monitoring) (Bias =
|
||
AV/500) (Unit = mA) <Help> This
|
||
measure gives the bias of the line
|
||
2 transceiver
|
||
"
|
||
::= { pmmcMesrLine 26 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line2TxPower article
|
||
--- *****************************************************
|
||
|
||
pmmcMesrline2TxPower OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 SFP Tx Power :This OID
|
||
gives the transmit power value
|
||
of the transceiver Line 2, read
|
||
from the DDM (Digital Diagnostic
|
||
Monitoring) (Power = 10*log(AV)-40)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Tx optical power of the
|
||
line 2 transceiver
|
||
"
|
||
::= { pmmcMesrLine 27 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the line2RxPower article
|
||
--- *****************************************************
|
||
|
||
pmmcMesrline2RxPower OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line 2 SFP Rx Power :This OID
|
||
gives the receive power value
|
||
of the transceiver Line 2, read
|
||
from the DDM (Digital Diagnostic
|
||
Monitoring) (Power = 10*log(AV)-40)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Rx optical power of the
|
||
line 2 transceiver
|
||
"
|
||
::= { pmmcMesrLine 28 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONFIG
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group lsd
|
||
--- *****************************************************
|
||
|
||
pmmcCfgLsd OBJECT IDENTIFIER ::= { pmmcConfig 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 0012
|
||
--- *****************************************************
|
||
|
||
pmmctableclientLsd OBJECT IDENTIFIER ::= { pmmcCfgLsd 1 }
|
||
|
||
|
||
|
||
pmmcCfglsdMode OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
CAIS mode on Lines Port :This
|
||
register selects the way to activate
|
||
the laser upon CAIS/CSF criteria
|
||
detection on Port
|
||
"
|
||
::= { pmmctableclientLsd 2 }
|
||
|
||
|
||
|
||
pmmcCfgline1AccessioCtrb OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
CAIS contributors on Line 1 Port
|
||
:This register selects the contributors
|
||
to upstream CAIS/CSF on Port
|
||
"
|
||
::= { pmmctableclientLsd 3 }
|
||
|
||
|
||
|
||
pmmcCfgline1CdrCtrb OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
CAIS contributors on Line 1 Port
|
||
:This register selects the contributors
|
||
to upstream CAIS/CSF on Port
|
||
"
|
||
::= { pmmctableclientLsd 4 }
|
||
|
||
|
||
|
||
pmmcCfgline2AccessioCtrb OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
CAIS contributors on Line 2 Port
|
||
:This register selects the contributors
|
||
to downstream CAIS/CSF on Port
|
||
"
|
||
::= { pmmctableclientLsd 5 }
|
||
|
||
|
||
|
||
pmmcCfgline2CdrCtrb OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
CAIS contributors on Line 2 Port
|
||
:This register selects the contributors
|
||
to downstream CAIS/CSF on Port
|
||
"
|
||
::= { pmmctableclientLsd 6 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group startUp
|
||
--- *****************************************************
|
||
|
||
pmmcCfgStartUp OBJECT IDENTIFIER ::= { pmmcConfig 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2111
|
||
--- *****************************************************
|
||
|
||
pmmctableclientStartup OBJECT IDENTIFIER ::= { pmmcCfgStartUp 1 }
|
||
|
||
|
||
|
||
pmmcCfgline1TrscvCtrl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line 1 :This
|
||
register configures the default
|
||
initialisation settings on Line
|
||
1.
|
||
"
|
||
::= { pmmctableclientStartup 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2191
|
||
--- *****************************************************
|
||
|
||
pmmctablelineStartup OBJECT IDENTIFIER ::= { pmmcCfgStartUp 2 }
|
||
|
||
|
||
|
||
pmmcCfgline2TrscvCtrl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line 2 :This
|
||
register configures the default
|
||
initialisation settings on Line
|
||
2.
|
||
"
|
||
::= { pmmctablelineStartup 2 }
|
||
|
||
|
||
|
||
pmmcCfgbitrateSelect OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Bitrate selection on Line 1/2
|
||
:This OID register configure the
|
||
bitrate for the client and line
|
||
interface (0=STS48 : 2,4 to 2,7
|
||
Gb/s - 1=1GBE : 1,2 to 1,35 Gb/s
|
||
- 2=STS12 : 600 to 675 Mb/s - 3=STS3
|
||
: 150 to 168 Mb/s - 4=2GFC : 2
|
||
to 2,4 Gb/s - 5=1GFC : 1,0 to
|
||
1,2 Gb/s - 6=500 to 600 Mb/s -
|
||
7=Fast Ethernet : 125 to 150 Mb/s
|
||
- 8=STS48 + FEC : 2,4-2,7 Gb/s
|
||
- 9=STS12 + FEC : 600-675 Mb/s
|
||
- 10=STS3 + FEC : 150-168 Mb/s
|
||
).
|
||
"
|
||
::= { pmmctablelineStartup 18 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group labels
|
||
--- *****************************************************
|
||
|
||
pmmcCfgLabels OBJECT IDENTIFIER ::= { pmmcConfig 3 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmmcCfgLabelclientTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PmmcCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmmcCfgLabels 1 }
|
||
|
||
|
||
pmmcCfgLabelclientEntry OBJECT-TYPE
|
||
SYNTAX PmmcCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmmcCfgLabelclientIndex }
|
||
::= { pmmcCfgLabelclientTable 1 }
|
||
|
||
|
||
PmmcCfgLabelclientEntry ::=
|
||
SEQUENCE {
|
||
pmmcCfgLabelclientIndex
|
||
INTEGER,
|
||
pmmcCfgLabelclientPortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmmcCfgLabelclientIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelclient
|
||
table
|
||
"
|
||
::= { pmmcCfgLabelclientEntry 1 }
|
||
|
||
|
||
pmmcCfgLabelclientPortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the Ports :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the ports.
|
||
"
|
||
::= { pmmcCfgLabelclientEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmmcCfgLabellineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PmmcCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmmcCfgLabels 2 }
|
||
|
||
|
||
pmmcCfgLabellineEntry OBJECT-TYPE
|
||
SYNTAX PmmcCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmmcCfgLabellineIndex }
|
||
::= { pmmcCfgLabellineTable 1 }
|
||
|
||
|
||
PmmcCfgLabellineEntry ::=
|
||
SEQUENCE {
|
||
pmmcCfgLabellineIndex
|
||
INTEGER,
|
||
pmmcCfgLabellinePortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmmcCfgLabellineIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelline
|
||
table
|
||
"
|
||
::= { pmmcCfgLabellineEntry 1 }
|
||
|
||
|
||
pmmcCfgLabellinePortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the lines :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the lines.
|
||
"
|
||
::= { pmmcCfgLabellineEntry 3 }
|
||
|
||
|
||
|
||
pmmcCfgWriteConfiguration OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Write configuration to module:This OID
|
||
writes the complete configuration to the module"
|
||
::= { pmmcConfig 257 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- TRAP OBJECTS
|
||
--- *****************************************************
|
||
|
||
pmmctrapBoardNumber OBJECT-TYPE
|
||
SYNTAX INTEGER(1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last module which generates a trap"
|
||
::= { pmmctraps 4 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LINE 1 TRAPS
|
||
--- *****************************************************
|
||
|
||
pmmcLine1TrapNotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine1TrscvDdmWarning, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 1 Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pmmcAlmLine1TrscvDdmWarning "on", pmmctrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on Line 1 of PMMC in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line 1 default is activated"
|
||
::= { pmmctraps 30 }
|
||
|
||
pmmcLine1TrapNotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine1TrscvDdmWarning, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 1 Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMMC Line 1 Not Urgent ON"}
|
||
--&MATCH { pmmcAlmLine1TrscvDdmWarning "on", pmmctrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning disappears on Line 1 of PMMC in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line 1 default disappeared"
|
||
::= { pmmctraps 31 }
|
||
|
||
pmmcLine1TrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine1TrscvDdmAlm, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 1 Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmmcAlmLine1TrscvDdmAlm "on", pmmctrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm appears on Line 1 of PMMC in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line 1 default is activated"
|
||
::= { pmmctraps 32 }
|
||
|
||
pmmcLine1TrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine1TrscvDdmAlm, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 1 Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMMC Line 1 Urgent ON"}
|
||
--&MATCH { pmmcAlmLine1TrscvDdmAlm "on", pmmctrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm disappears on Line 1 of PMMC in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line 1 default disappeared"
|
||
::= { pmmctraps 33 }
|
||
|
||
pmmcLine1TrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine1Fail, pmmcAlmLine1HwFail, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 1 Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pmmcAlmLine1Fail "on", pmmcAlmLine1HwFail "*", pmmctrapBoardNumber "$3"}
|
||
--&MESG "Line Port 1 Down on PMMC in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMMC Line 1 HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmmcAlmLine1Fail "*", pmmcAlmLine1HwFail "on", pmmctrapBoardNumber "$3"}
|
||
--&MESG "Line Port 1 Down on PMMC in Slot $3 ($A)"
|
||
DESCRIPTION "Critical Line 1 default is activated"
|
||
::= { pmmctraps 34 }
|
||
|
||
pmmcLine1TrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine1Fail, pmmcAlmLine1HwFail, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 1 Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMMC Line 1 Fail ON"}
|
||
--&MATCH { pmmcAlmLine1Fail "on", pmmcAlmLine1HwFail "*", pmmctrapBoardNumber "$3"}
|
||
--&MESG "Line Port 1 Up on PMMC in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMMC Line 1 HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmmcAlmLine1Fail "*", pmmcAlmLine1HwFail "on", pmmctrapBoardNumber "$3"}
|
||
--&MESG "Line Port 1 Up on PMMC in Slot $3 ($A)"
|
||
DESCRIPTION "Critical Line 1 default disappeared"
|
||
::= { pmmctraps 35 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LINE 2 TRAPS
|
||
--- *****************************************************
|
||
|
||
pmmcLine2NotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine2TrscvDdmWarning, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 2 Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pmmcAlmLine2TrscvDdmWarning "on", pmmctrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on Line 2 of PMMC in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line 2 default is activated"
|
||
::= { pmmctraps 40 }
|
||
|
||
pmmcLine2NotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine2TrscvDdmWarning, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 2 Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMMC Line 2 Not Urgent ON"}
|
||
--&MATCH { pmmcAlmLine2TrscvDdmWarning "on", pmmctrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning disappears on Line 2 of PMMC in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line 2 default disappeared"
|
||
::= { pmmctraps 41 }
|
||
|
||
pmmcLine2UrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine2TrscvDdmAlm, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 2 Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmmcAlmLine2TrscvDdmAlm "on", pmmctrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm appears on Line 2 of PMMC in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line 2 default is activated"
|
||
::= { pmmctraps 42 }
|
||
|
||
pmmcLine2UrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine2TrscvDdmAlm, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 2 Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMMC Line 2 Urgent ON"}
|
||
--&MATCH { pmmcAlmLine2TrscvDdmAlm "on", pmmctrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm disappears on Line 2 of PMMC in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line 2 default disappeared"
|
||
::= { pmmctraps 43 }
|
||
|
||
pmmcLine2CritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine2Fail, pmmcAlmLine2HwFail, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 2 Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pmmcAlmLine2Fail "on", pmmcAlmLine2HwFail "*", pmmctrapBoardNumber "$3"}
|
||
--&MESG "Line Port 2 Down on PMMC in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMMC Line 2 HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmmcAlmLine2Fail "*", pmmcAlmLine2HwFail "on", pmmctrapBoardNumber "$3"}
|
||
--&MESG "Line Port 2 Down on PMMC in Slot $3 ($A)"
|
||
DESCRIPTION "Critical Line 2 default is activated"
|
||
::= { pmmctraps 44 }
|
||
|
||
pmmcLine2CritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmLine2Fail, pmmcAlmLine2HwFail, pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Line 2 Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMMC Line 2 Fail ON"}
|
||
--&MATCH { pmmcAlmLine2Fail "on", pmmcAlmLine2HwFail "*", pmmctrapBoardNumber "$3"}
|
||
--&MESG "Line Port 2 Up on PMMC in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMMC Line 2 HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmmcAlmLine2Fail "*", pmmcAlmLine2HwFail "on", pmmctrapBoardNumber "$3"}
|
||
--&MESG "Line Port 2 Up on PMMC in Slot $3 ($A)"
|
||
DESCRIPTION "Critical Line 2 default disappeared"
|
||
::= { pmmctraps 45 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- HW TRAPS
|
||
--- *****************************************************
|
||
|
||
pmmcPowerTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmDefFuseB, pmmcAlmDefFuseA , pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Fuse A Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmmcAlmDefFuseB "*", pmmcAlmDefFuseA "on", pmmctrapBoardNumber "$3"}
|
||
--&MESG "Power Input A Fail on PMMC in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMMC Fuse B Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmmcAlmDefFuseB "on", pmmcAlmDefFuseA "*", pmmctrapBoardNumber "$3"}
|
||
--&MESG "Power Input B Fail on PMMC in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default is activated"
|
||
::= { pmmctraps 50 }
|
||
pmmcPowerTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmmcAlmDefFuseB, pmmcAlmDefFuseA , pmmctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMMC Fuse A&B Fail OFF"
|
||
--&ACTIONS { log, normal}
|
||
--&CLEARS { "PMMC Fuse A Fail ON", "PMMC Fuse B Fail ON" }
|
||
--&MATCH { pmmcAlmDefFuseB "on", pmmcAlmDefFuseA "on", pmmctrapBoardNumber "$3"}
|
||
--&MESG "Power Inputs A and B Present on PMMC in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default disappeared"
|
||
::= { pmmctraps 51 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
END
|