-- ***************************************************************** -- EKINOPS-PmMC.TXT: MIB -- --MIB Part Number:3MI00120AJAD --MIB Version:02 -- -- Copyright (c) 2016 by Ekinops -- All rights reserved. -- -- ***************************************************************** EKINOPS-PmMC-MIB DEFINITIONS ::= BEGIN IMPORTS ekinops, EkiState, EkiOnOff, EkiMode, EkiProtocol, EkiApiState, EkiSynchroMode, EkiMeasureType FROM EKINOPS-MIB MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Unsigned32, Integer32, Counter32, IpAddress FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC; modulePmMC MODULE-IDENTITY LAST-UPDATED "201605230000Z" ORGANIZATION "Ekinops" CONTACT-INFO "Ekinops 3, rue Blaise Pascal F-22300 Lannion / FRANCE Tel : +33 (0)2 96 05 00 30 Fax : +33 (0)2 96 48 62 39 E-mail: support@ekinops.net" DESCRIPTION "MIB for the Ekinops Pmmc hardware." REVISION "200701100000Z" DESCRIPTION "Initial Version." REVISION "200706290000Z" DESCRIPTION "°C changed to C" REVISION "200708230000Z" DESCRIPTION "°Add Alarms Objects" REVISION "200711210000Z" DESCRIPTION "°Add Config Object, Update Ekinops address, Helps on objects, Ports Labels" REVISION "200904100000Z" DESCRIPTION "Cosmetics for mib compilers" REVISION "200909180000Z" DESCRIPTION "CondType Parameters insertion" REVISION "201002250000Z" DESCRIPTION "Probcause,AlarmType - NMS" REVISION "201011040000Z" DESCRIPTION "Formulas and Event on XFP init" REVISION "201012170000Z" DESCRIPTION "Fix on Smpc trap" REVISION "201207040000Z" DESCRIPTION "Minor cosmetic updates" REVISION "201403260000Z" DESCRIPTION "Probcause,AlarmType - NMS completion" REVISION "201412110000Z" DESCRIPTION "Labels cosmetic updates" REVISION "201605230000Z" DESCRIPTION "New AlarmType – synthesisAlarm (12)" ::= { ekinops 21 } --- ***************************************************** --- LEAF LEVEL 2 --- ***************************************************** pmmcalarms OBJECT IDENTIFIER ::= { modulePmMC 2 } pmmcAlmOther OBJECT IDENTIFIER ::= { pmmcalarms 1 } pmmcAlmOtherNurg OBJECT IDENTIFIER ::= { pmmcAlmOther 1 } pmmcAlmOtherUrg OBJECT IDENTIFIER ::= { pmmcAlmOther 2 } pmmcAlmOtherCrit OBJECT IDENTIFIER ::= { pmmcAlmOther 3 } pmmcAlmClient OBJECT IDENTIFIER ::= { pmmcalarms 2 } pmmcAlmClientNurg OBJECT IDENTIFIER ::= { pmmcAlmClient 1 } pmmcAlmClientUrg OBJECT IDENTIFIER ::= { pmmcAlmClient 2 } pmmcAlmClientCrit OBJECT IDENTIFIER ::= { pmmcAlmClient 3 } pmmcAlmLine OBJECT IDENTIFIER ::= { pmmcalarms 3 } pmmcAlmLineNurg OBJECT IDENTIFIER ::= { pmmcAlmLine 1 } pmmcAlmLineUrg OBJECT IDENTIFIER ::= { pmmcAlmLine 2 } pmmcAlmLineCrit OBJECT IDENTIFIER ::= { pmmcAlmLine 3 } pmmcmeasures OBJECT IDENTIFIER ::= { modulePmMC 3 } pmmcMesrOther OBJECT IDENTIFIER ::= { pmmcmeasures 1 } pmmcMesrClient OBJECT IDENTIFIER ::= { pmmcmeasures 2 } pmmcMesrLine OBJECT IDENTIFIER ::= { pmmcmeasures 3 } pmmccontrolsWrite OBJECT IDENTIFIER ::= { modulePmMC 6 } pmmcCtrlOther OBJECT IDENTIFIER ::= { pmmccontrolsWrite 1 } pmmcCtrlClient OBJECT IDENTIFIER ::= { pmmccontrolsWrite 2 } pmmcCtrlLine OBJECT IDENTIFIER ::= { pmmccontrolsWrite 3 } pmmcri OBJECT IDENTIFIER ::= { modulePmMC 7 } pmmcConfig OBJECT IDENTIFIER ::= { modulePmMC 9 } pmmctraps OBJECT IDENTIFIER ::= { modulePmMC 10 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- TEXTUAL-CONVENTION --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** PmmcBitRate ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "different rates for a client and line ports" SYNTAX INTEGER { rateSTM16OC48(0), rate1GBE(1), rateSTM4OC12(2), rateSTM1OC3(3), rate2GFC(4), rate1GFC(5), rateFastEthernet(7), rateSTM16FEC(8), rateSTM4FEC(9), rateSTM1FEC(10) } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- REMOTE INVENTORY --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** pmmcRinvReloadInventory OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Reload the inventory: This OID triggers an inventory reload." ::= { pmmcri 2 } pmmcRinvHwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Module platform description: This OID contains the description of the Module." ::= { pmmcri 4 } pmmcRinvSwPlatform OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "SW platform description: This OID contains the description of the Software platform." ::= { pmmcri 5 } pmmcRinvLine1SFP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the SFP: This OID contains the inventory for the Port A SFP" ::= { pmmcri 6 } pmmcRinvLine2SFP OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Inventory for the SFP: This OID contains the inventory for the Port B SFP" ::= { pmmcri 7 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ALARMS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synthAlm0 article --- ***************************************************** pmmcAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmmcAlmOtherCrit 0 } pmmcAlmDefFuseB OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition Status of the Fuse B DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) " ::= { pmmcAlmsynthAlm0 16 } pmmcAlmDefFuseA OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition Status of the Fuse A DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) " ::= { pmmcAlmsynthAlm0 15 } pmmcAlmSynUnlock OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Synthesizer Not Locked :This OID indicates that the frequency synthesizer is not locked. This status indicates if the clock synthesizer is locked. SYN_UNLOCK equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmmcAlmsynthAlm0 14 } pmmcAlmModuleGlobFailure OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Module Failure :This OID is set on detection of a failure originating from the PM MODULE_GLOB_FAILURE equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmmcAlmsynthAlm0 9 } --- ***************************************************** --- LEAF for the synthAlm7 article --- ***************************************************** pmmcAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmmcAlmLineCrit 7 } pmmcAlmLine2Fail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 Failure :This OID indicates a failure on the Line 2 LINE2_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmmcAlmsynthAlm7 12 } pmmcAlmLine2TrscvDdmAlm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm DDM On Optical Module 2 :This OID indicates an alarm is present coming out of optical interface DDM on Line 2 This alarm indicates if a DDM Alarm has been detected on the line 2 transceiver LINE2_TRSCV_DDM_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmmcAlmsynthAlm7 10 } pmmcAlmLine2TrscvDdmWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning DDM On Optical Module 2 :This OID indicates a warning is present coming out of optical interface DDM on Line 2 This alarm indicates if a DDM Warning has been detected on the line 2 transceiver LINE2_TRSCV_DDM_WARNING equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmmcAlmsynthAlm7 9 } pmmcAlmLine2TrscvLsd OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 SFP Laser Shutdown :This OID indicates the optical output power is off on Line 2 This status indicates if the line 2 transceiver laser is ON or OFF LINE2_TRSCV_LSD other (1) equipmentAlarm (5) (2) " ::= { pmmcAlmsynthAlm7 5 } pmmcAlmLine2HwFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 HW Failure :This OID indicates a hardware failure on the Line 2 LINE2_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmmcAlmsynthAlm7 4 } pmmcAlmLine2TrscvDdmAbsent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " DDM Supported On Line 2 SFP :This OID indicates that the transceiver module 2 does not support Digital Diagnostic Monitoring Functions This status indicates if the line 2 transceiver includes the DDM feature LINE2_TRSCV_DDM_ABSENT informationalStatus(1000) other (1) (2) " ::= { pmmcAlmsynthAlm7 2 } pmmcAlmLine2TrscvAbsent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 SFP Absent :This OID indicates that the transceiver module 2 is not present. This alarm indicates if the line 2 transceiver is present. LINE2_TRSCV_ABSENT inputOutputDeviceError (24) equipmentAlarm (5) (2) ObjectCDINV " ::= { pmmcAlmsynthAlm7 1 } --- ***************************************************** --- LEAF for the synthAlm8 article --- ***************************************************** pmmcAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmmcAlmClientCrit 8 } pmmcAlmLine1Fail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 Failure :This OID indicates a failure on the Line 1 LINE1_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmmcAlmsynthAlm8 12 } pmmcAlmLine1TrscvDdmAlm OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Alarm DDM On Optical Module 1 :This OID indicates an alarm is present coming out of optical interface DDM on Line 1 This alarm indicates if a DDM Alarm has been detected on the line 1 transceiver LINE1_TRSCV_DDM_ALM equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmmcAlmsynthAlm8 10 } pmmcAlmLine1TrscvDdmWarning OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Warning DDM On Optical Module 1 :This OID indicates a warning is present coming out of optical interface DDM on Line 1 This alarm indicates if a DDM Warning has been detected on the line 1 transceiver LINE1_TRSCV_DDM_WARNING equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmmcAlmsynthAlm8 9 } pmmcAlmLine1TrscvLsd OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 SFP Laser Shutdown :This OID indicates the optical output power is off on Line 1 This status indicates if the line 1 transceiver laser is ON or OFF LINE1_TRSCV_LSD other (1) equipmentAlarm (5) (2) " ::= { pmmcAlmsynthAlm8 5 } pmmcAlmLine1HwFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 HW Failure :This OID indicates a hardware failure on the Line 1 LINE1_HW_FAIL equipmentMalfunction (16) synthesisAlarm (12) (2) " ::= { pmmcAlmsynthAlm8 4 } pmmcAlmLine1TrscvDdmAbsent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " DDM Supported On Line 1 SFP :This OID indicates that the transceiver module 1 does not support Digital Diagnostic Monitoring Functions This status indicates if the line 1 transceiver includes the DDM feature LINE1_TRSCV_DDM_ABSENT informationalStatus(1000) other (1) (2) " ::= { pmmcAlmsynthAlm8 2 } pmmcAlmLine1TrscvAbsent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 SFP Absent :This OID indicates that the transceiver module 2 is not present. This alarm indicates if the line 1 transceiver is present. LINE1_TRSCV_ABSENT inputOutputDeviceError (24) equipmentAlarm (5) (2) ObjectCDINV " ::= { pmmcAlmsynthAlm8 1 } --- ***************************************************** --- LEAF for the line1AccessioAlm article --- ***************************************************** pmmcAlmline1AccessioAlm OBJECT IDENTIFIER ::= { pmmcAlmClientCrit 16 } pmmcAlmLine1Los OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Loss Of Optical Signal On Line 1 :This OID indicates that no signal is present on the transceiver 1 This alarm indicates if an optical signal is detected on the line 1 transceiver input LINE1_LOS receiveFailure (41) physicalViolation (9) (2) " ::= { pmmcAlmline1AccessioAlm 4 } pmmcAlmLine1LasFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 SFP Tx Failed :This OID indicates that the transmitter fails for the transceiver plugged into the Line 1 (this alarm reports the transmitter failure alarm generated by the transceivers) This alarm indicates if the laser of the Line 1 transceiver is in fail condition LINE1_LAS_FAIL transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline1AccessioAlm 1 } --- ***************************************************** --- LEAF for the line1TrscvAlmDdm article --- ***************************************************** pmmcAlmline1TrscvAlmDdm OBJECT IDENTIFIER ::= { pmmcAlmClientUrg 18 } pmmcAlmLine1RxPwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Rx Power High :Alarm indicating that the transceiver input power of Line 1 is higher than the threshold value written in the transceiver EEPROM LINE1_RX_PWR_HIGH_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvAlmDdm 16 } pmmcAlmLine1RxPwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Rx Power Low :Alarm indicating that the transceiver input power of Line 1 is lower than the threshold value written in the transceiver EEPROM LINE1_RX_PWR_LOW_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvAlmDdm 15 } pmmcAlmLine1TempHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Temp High :Alarm indicating that the transceiver temperature of Line 1 is higher than the threshold value written in the transceiver EEPROM LINE1_TEMP_HIGH_ALA temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvAlmDdm 8 } pmmcAlmLine1TempLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Temp Low :Alarm indicating that the transceiver temperature of Line 1 is lower than the threshold value written in the transceiver EEPROM LINE1_TEMP_LOW_ALA temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvAlmDdm 7 } pmmcAlmLine1VccHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Power Supply High :Alarm indicating that the transceiver power supply of Line 1 is higher than the threshold value written in the transceiver EEPROM LINE1_VCC_HIGH_ALA powerProblem (36) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvAlmDdm 6 } pmmcAlmLine1VccLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Power Supply Low :Alarm indicating that the transceiver power supply of Line 1 is lower than the threshold value written in the transceiver EEPROM LINE1_VCC_LOW_ALA powerProblem (36) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvAlmDdm 5 } pmmcAlmLine1TxBiasHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Bias High :Alarm indicating that the transceiver laser bias current of Line 1 is higher than the threshold value written in the transceiver EEPROM LINE1_TX_BIAS_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvAlmDdm 4 } pmmcAlmLine1TxBiasLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Bias Low :Alarm indicating that the transceiver laser bias current of Line 1 is lower than the threshold value written in the transceiver EEPROM LINE1_TX_BIAS_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvAlmDdm 3 } pmmcAlmLine1TxPwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Tx Power High :Alarm indicating that the transceiver output power of Line 1 is higher than the threshold value written in the transceiver EEPROM LINE1_TX_PWR_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvAlmDdm 2 } pmmcAlmLine1TxPwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Tx Power Low :Alarm indicating that the transceiver output power of Line 1 is lower than the threshold value written in the transceiver EEPROM LINE1_TX_PWR_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvAlmDdm 1 } --- ***************************************************** --- LEAF for the line1TrscvWarnDdm article --- ***************************************************** pmmcAlmline1TrscvWarnDdm OBJECT IDENTIFIER ::= { pmmcAlmClientNurg 20 } pmmcAlmLine1RxPwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Rx Power High Warning :Warning indicating that the transceiver input power of Line 1 is higher than the threshold value written in the transceiver EEPROM LINE1_RX_PWR_HIGH_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvWarnDdm 16 } pmmcAlmLine1RxPwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Rx Power Low Warning :Warning indicating that the transceiver input power of Line 1 is lower than the threshold value written in the transceiver EEPROM LINE1_RX_PWR_LOW_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvWarnDdm 15 } pmmcAlmLine1TempHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Temp High Warning :Warning indicating that the transceiver temperature of Line 1 is higher than the threshold value written in the transceiver EEPROM LINE1_TEMP_HIGH_WNG temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvWarnDdm 8 } pmmcAlmLine1TempLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Temp Low Warning :Warning indicating that the transceiver temperature of Line 1 is lower than the threshold value written in the transceiver EEPROM LINE1_TEMP_LOW_WNG temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvWarnDdm 7 } pmmcAlmLine1VccHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Power Supply High Warning :Warning indicating that the transceiver power supply of Line 1 is higher than the threshold value written in the transceiver EEPROM LINE1_VCC_HIGH_WNG powerProblem (36) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvWarnDdm 6 } pmmcAlmLine1VccLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Power Supply Low Warning :Warning indicating that the transceiver power supply of Line 1 is lower than the threshold value written in the transceiver EEPROM LINE1_VCC_LOW_WNG powerProblem (36) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvWarnDdm 5 } pmmcAlmLine1TxBiasHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Bias High Warning :Warning indicating that the transceiver laser bias current of Line 1 is higher than the threshold value written in the transceiver EEPROM LINE1_TX_BIAS_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvWarnDdm 4 } pmmcAlmLine1TxBiasLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Bias Low Warning :Warning indicating that the transceiver laser bias current of Line 1 is lower than the threshold value written in the transceiver EEPROM LINE1_TX_BIAS_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvWarnDdm 3 } pmmcAlmLine1TxPwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Tx Power High Warning :Warning indicating that the transceiver output power of Line 1 is higher than the threshold value written in the transceiver EEPROM LINE1_TX_PWR_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvWarnDdm 2 } pmmcAlmLine1TxPwLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 1 Tx Power Low Warning :Warning indicating that the transceiver output power of Line 1 is lower than the threshold value written in the transceiver EEPROM LINE1_TX_PW_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline1TrscvWarnDdm 1 } --- ***************************************************** --- LEAF for the line1CdrAlm article --- ***************************************************** pmmcAlmline1CdrAlm OBJECT IDENTIFIER ::= { pmmcAlmClientNurg 23 } pmmcAlmLine1CdrRefAbsent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 CDR Reference Clock Absent :This OID indicates that the CDR reference clock is absent on Line 1 This alarm indicates if the reference clock is present on the line 1 CDR LINE1_CDR_REF_ABSENT equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmmcAlmline1CdrAlm 3 } pmmcAlmLine1CdrLossoflock OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 CDR Loss Of Lock :This OID indicates that the Line 1 CDR is not locked This alarm indicates if Line 1 CDR is correclty locked on the input signal LINE1_CDR_LOSSOFLOCK receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline1CdrAlm 2 } pmmcAlmLine1CdrLossofsignal OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 CDR Loss Of Signal :This OID indicates that a Loss of electrical signal is detected on the Line 1 CDR This alarm indicates if an electrical signal is detected on the line 1 CDR LINE1_CDR_LOSSOFSIGNAL receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline1CdrAlm 1 } --- ***************************************************** --- LEAF for the line2AccessioAlm article --- ***************************************************** pmmcAlmline2AccessioAlm OBJECT IDENTIFIER ::= { pmmcAlmLineCrit 24 } pmmcAlmLine2Los OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Loss Of Optical Signal On Line 2 :This OID indicates that no signal is present on the transceiver 2 This alarm indicates if an optical signal is detected on the line 2 transceiver input LINE2_LOS receiveFailure (41) physicalViolation (9) (2) " ::= { pmmcAlmline2AccessioAlm 4 } pmmcAlmLine2LasFail OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 SFP Tx Failed :This OID indicates that the transmitter fails for the transceiver plugged into the Line 1 (this alarm reports the transmitter failure alarm generated by the transceivers) This alarm indicates if the laser of the line 2 transceiver is in fail condition LINE2_LAS_FAIL transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline2AccessioAlm 1 } --- ***************************************************** --- LEAF for the line2TrscvAlmDdm article --- ***************************************************** pmmcAlmline2TrscvAlmDdm OBJECT IDENTIFIER ::= { pmmcAlmLineUrg 26 } pmmcAlmLine2RxPwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Rx Power High :Alarm indicating that the transceiver input power of Line 2 is higher than the threshold value written in the transceiver EEPROM LINE2_RX_PWR_HIGH_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvAlmDdm 16 } pmmcAlmLine2RxPwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Rx Power Low :Alarm indicating that the transceiver input power of Line 2 is lower than the threshold value written in the transceiver EEPROM LINE2_RX_PWR_LOW_ALA receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvAlmDdm 15 } pmmcAlmLine2TempHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Temp High :Alarm indicating that the transceiver temperature of Line 2 is higher than the threshold value written in the transceiver EEPROM LINE2_TEMP_HIGH_ALA temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvAlmDdm 8 } pmmcAlmLine2TempLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Temp Low :Alarm indicating that the transceiver temperature of Line 2 is lower than the threshold value written in the transceiver EEPROM LINE2_TEMP_LOW_ALA temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvAlmDdm 7 } pmmcAlmLine2VccHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Power Supply High :Alarm indicating that the transceiver power supply of Line 2 is higher than the threshold value written in the transceiver EEPROM LINE2_VCC_HIGH_ALA powerProblem (36) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvAlmDdm 6 } pmmcAlmLine2VccLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Power Supply Low :Alarm indicating that the transceiver power supply of Line 2 is lower than the threshold value written in the transceiver EEPROM LINE2_VCC_LOW_ALA powerProblem (36) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvAlmDdm 5 } pmmcAlmLine2TxBiasHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Bias High :Alarm indicating that the transceiver laser bias current of Line 2 is higher than the threshold value written in the transceiver EEPROM LINE2_TX_BIAS_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvAlmDdm 4 } pmmcAlmLine2TxBiasLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Bias Low :Alarm indicating that the transceiver laser bias current of Line 2 is lower than the threshold value written in the transceiver EEPROM LINE2_TX_BIAS_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvAlmDdm 3 } pmmcAlmLine2TxPwrHighAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Tx Power High :Alarm indicating that the transceiver output power of Line 2 is higher than the threshold value written in the transceiver EEPROM LINE2_TX_PWR_HIGH_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvAlmDdm 2 } pmmcAlmLine2TxPwrLowAla OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Tx Power Low :Alarm indicating that the transceiver output power of Line 2 is lower than the threshold value written in the transceiver EEPROM LINE2_TX_PWR_LOW_ALA transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvAlmDdm 1 } --- ***************************************************** --- LEAF for the line2TrscvWarnDdm article --- ***************************************************** pmmcAlmline2TrscvWarnDdm OBJECT IDENTIFIER ::= { pmmcAlmLineNurg 28 } pmmcAlmLine2RxPwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Rx Power High Warning :Warning indicating that the transceiver input power of Line 2 is higher than the threshold value written in the transceiver EEPROM LINE2_RX_PWR_HIGH_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvWarnDdm 16 } pmmcAlmLine2RxPwrLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Rx Power Low Warning :Warning indicating that the transceiver input power of Line 2 is lower than the threshold value written in the transceiver EEPROM LINE2_RX_PWR_LOW_WNG receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvWarnDdm 15 } pmmcAlmLine2TempHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Temp High Warning :Warning indicating that the transceiver temperature of Line 2 is higher than the threshold value written in the transceiver EEPROM LINE2_TEMP_HIGH_WNG temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvWarnDdm 8 } pmmcAlmLine2TempLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Temp Low Warning :Warning indicating that the transceiver temperature of Line 2 is lower than the threshold value written in the transceiver EEPROM LINE2_TEMP_LOW_WNG temperatureUnacceptable (51) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvWarnDdm 7 } pmmcAlmLine2VccHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Power Supply High Warning :Warning indicating that the transceiver power supply of Line 2 is higher than the threshold value written in the transceiver EEPROM LINE2_VCC_HIGH_WNG powerProblem (36) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvWarnDdm 6 } pmmcAlmLine2VccLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Power Supply Low Warning :Warning indicating that the transceiver power supply of Line 2 is lower than the threshold value written in the transceiver EEPROM LINE2_VCC_LOW_WNG powerProblem (36) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvWarnDdm 5 } pmmcAlmLine2TxBiasHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Bias High Warning :Warning indicating that the transceiver laser bias current of Line 2 is higher than the threshold value written in the transceiver EEPROM LINE2_TX_BIAS_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvWarnDdm 4 } pmmcAlmLine2TxBiasLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Bias Low Warning :Warning indicating that the transceiver laser bias current of Line 2 is lower than the threshold value written in the transceiver EEPROM LINE2_TX_BIAS_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvWarnDdm 3 } pmmcAlmLine2TxPwrHighWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Tx Power High Warning :Warning indicating that the transceiver output power of Line 2 is higher than the threshold value written in the transceiver EEPROM LINE2_TX_PWR_HIGH_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvWarnDdm 2 } pmmcAlmLine2TxPwLowWng OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " TRSCV 2 Tx Power Low Warning :Warning indicating that the transceiver output power of Line 2 is lower than the threshold value written in the transceiver EEPROM LINE2_TX_PW_LOW_WNG transmitterFailure (56) equipmentAlarm (5) (2) " ::= { pmmcAlmline2TrscvWarnDdm 1 } --- ***************************************************** --- LEAF for the line2CdrAlm article --- ***************************************************** pmmcAlmline2CdrAlm OBJECT IDENTIFIER ::= { pmmcAlmLineNurg 31 } pmmcAlmLine2CdrRefAbsent OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 CDR Reference Clock Absent :This OID indicates that the CDR reference clock is absent on Line 2 This alarm indicates if the reference clock is present on the line 2 CDR LINE2_CDR_REF_ABSENT equipmentMalfunction (16) equipmentAlarm (5) (2) " ::= { pmmcAlmline2CdrAlm 3 } pmmcAlmLine2CdrLossoflock OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 CDR Loss Of Lock :This OID indicates that the Line 2 CDR is not locked This alarm indicates if Line 2 CDR is correclty locked on the input signal LINE2_CDR_LOSSOFLOCK receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline2CdrAlm 2 } pmmcAlmLine2CdrLossofsignal OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 CDR Loss Of Signal :This OID indicates that a Loss of electrical signal is detected on the Line 2 CDR This alarm indicates if an electrical signal is detected on the line 2 CDR LINE2_CDR_LOSSOFSIGNAL receiveFailure (41) equipmentAlarm (5) (2) " ::= { pmmcAlmline2CdrAlm 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONTROLS --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the synth0 article --- ***************************************************** pmmcCtrlsynth0 OBJECT IDENTIFIER ::= { pmmcCtrlOther 0 } pmmcCtrlConfClear OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Clear Configuration Tables :This bit clears the configuration tables from configuration in the flash. This control restores the default configuration of the module " ::= { pmmcCtrlsynth0 13 } pmmcCtrlConfFlash OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Write Configuration Tables :This bit saves the current configuration of the module as configuration in the flash. This control saves the customer configuration on the module " ::= { pmmcCtrlsynth0 9 } pmmcCtrlConfLoad OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Load Configuration Tables :When set this enables loading from flash configuration1 into the module. " ::= { pmmcCtrlsynth0 1 } --- ***************************************************** --- LEAF for the synth4 article --- ***************************************************** pmmcCtrlsynth4 OBJECT IDENTIFIER ::= { pmmcCtrlOther 4 } pmmcCtrlCorrelatOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Disable Alarm Correlation :This OID disables the alarm correlation in the PM. " ::= { pmmcCtrlsynth4 2 } pmmcCtrlCorrelatOn OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Enable Alarm Correlation :This OID enables the alarm correlation in the PM. " ::= { pmmcCtrlsynth4 1 } --- ***************************************************** --- LEAF for the swMgnt article --- ***************************************************** pmmcCtrlswMgnt OBJECT IDENTIFIER ::= { pmmcCtrlOther 5 } pmmcCtrlWarmReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Warm Reset :This OID, when set, causes a warm reset of the Software. This reset is not traffic affecting, and the configuration of the Sofwtare remains unchanged. This control initiates a warm reset of the module. " ::= { pmmcCtrlswMgnt 3 } pmmcCtrlColdReset OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " PM Cold Reset :This OID, when set, causes a cold reset of the Software. This reset is traffic affecting, and the configuration of Software is reloaded on start-up. This control initiates a cold reset of the module. " ::= { pmmcCtrlswMgnt 2 } --- ***************************************************** --- LEAF for the line1TrscvOnoff article --- ***************************************************** pmmcCtrlline1TrscvOnoff OBJECT IDENTIFIER ::= { pmmcCtrlClient 16 } pmmcCtrlLine1TrscvOnoff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Line 1 SFP Laser Shutdown :This OID switches off the transceiver on Line 1 This control defines the laser state of the line 1 transceiver " ::= { pmmcCtrlline1TrscvOnoff 1 } --- ***************************************************** --- LEAF for the line2TrscvOnoff article --- ***************************************************** pmmcCtrlline2TrscvOnoff OBJECT IDENTIFIER ::= { pmmcCtrlLine 24 } pmmcCtrlLine2TrscvOnoff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Line 2 SFP Laser Shutdown :This OID switches off the transceiver on Line 2 This control defines the laser state of the line 2 transceiver " ::= { pmmcCtrlline2TrscvOnoff 1 } --- ***************************************************** --- LEAF for the ledTest article --- ***************************************************** pmmcCtrlledTest OBJECT IDENTIFIER ::= { pmmcCtrlOther 64 } pmmcCtrlLedOff OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Leds Off :This OID switches off all the Leds as a test feature. This control initiates a test leds turning all the LEDs to OFF " ::= { pmmcCtrlledTest 3 } pmmcCtrlRedLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Red Leds Test :This OID switches on all the red Leds as a test feature. This control initiates a test leds turning all the LEDs to red " ::= { pmmcCtrlledTest 2 } pmmcCtrlGreenLed OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION " Green Leds Test :This OID switches on all the green Leds as a test feature. This control initiates a test leds turning all the LEDs to green " ::= { pmmcCtrlledTest 1 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- MEASURES --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the line1Temperature article --- ***************************************************** pmmcMesrline1Temperature OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 SFP Temperature :This OID gives the temperature of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This measure gives the temperature of the line 1 transceiver " ::= { pmmcMesrClient 16 } --- ***************************************************** --- LEAF for the line1Volt article --- ***************************************************** pmmcMesrline1Volt OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 SFP Power Supply :This OID gives the voltage of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) This measure gives the 3V3 voltage of the line 1 transceiver " ::= { pmmcMesrClient 17 } --- ***************************************************** --- LEAF for the line1TxBias article --- ***************************************************** pmmcMesrline1TxBias OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 SFP Laser Bias :This OID gives the bias value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) This measure gives the bias of the line 1 transceiver " ::= { pmmcMesrClient 18 } --- ***************************************************** --- LEAF for the line1TxPower article --- ***************************************************** pmmcMesrline1TxPower OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 SFP Tx Power :This OID gives the transmit power value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This measure gives the Tx optical power of the line 1 transceiver " ::= { pmmcMesrClient 19 } --- ***************************************************** --- LEAF for the line1RxPower article --- ***************************************************** pmmcMesrline1RxPower OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 1 SFP Rx Power :This OID gives the receive power value of the transceiver Line 1, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This measure gives the Rx optical power of the line 1 transceiver " ::= { pmmcMesrClient 20 } --- ***************************************************** --- LEAF for the line2Temperature article --- ***************************************************** pmmcMesrline2Temperature OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 SFP Temperature :This OID gives the temperature of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Temperature = AV/256) (Unit = C) This measure gives the temperature of the line 2 transceiver " ::= { pmmcMesrLine 24 } --- ***************************************************** --- LEAF for the line2Volt article --- ***************************************************** pmmcMesrline2Volt OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 SFP Power Supply :This OID gives the voltage of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Voltage = AV/10000) (Unit = V) This measure gives the 3V3 voltage of the line 2 transceiver " ::= { pmmcMesrLine 25 } --- ***************************************************** --- LEAF for the line2TxBias article --- ***************************************************** pmmcMesrline2TxBias OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 SFP Laser Bias :This OID gives the bias value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Bias = AV/500) (Unit = mA) This measure gives the bias of the line 2 transceiver " ::= { pmmcMesrLine 26 } --- ***************************************************** --- LEAF for the line2TxPower article --- ***************************************************** pmmcMesrline2TxPower OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 SFP Tx Power :This OID gives the transmit power value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This measure gives the Tx optical power of the line 2 transceiver " ::= { pmmcMesrLine 27 } --- ***************************************************** --- LEAF for the line2RxPower article --- ***************************************************** pmmcMesrline2RxPower OBJECT-TYPE SYNTAX Unsigned32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Line 2 SFP Rx Power :This OID gives the receive power value of the transceiver Line 2, read from the DDM (Digital Diagnostic Monitoring) (Power = 10*log(AV)-40) (Unit = dBm) This measure gives the Rx optical power of the line 2 transceiver " ::= { pmmcMesrLine 28 } --- ***************************************************** --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- CONFIG --- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$ --- ***************************************************** --- ***************************************************** --- LEAF for the table Group lsd --- ***************************************************** pmmcCfgLsd OBJECT IDENTIFIER ::= { pmmcConfig 1 } --- ***************************************************** --- LEAF for the table 0012 --- ***************************************************** pmmctableclientLsd OBJECT IDENTIFIER ::= { pmmcCfgLsd 1 } pmmcCfglsdMode OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " CAIS mode on Lines Port :This register selects the way to activate the laser upon CAIS/CSF criteria detection on Port " ::= { pmmctableclientLsd 2 } pmmcCfgline1AccessioCtrb OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " CAIS contributors on Line 1 Port :This register selects the contributors to upstream CAIS/CSF on Port " ::= { pmmctableclientLsd 3 } pmmcCfgline1CdrCtrb OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " CAIS contributors on Line 1 Port :This register selects the contributors to upstream CAIS/CSF on Port " ::= { pmmctableclientLsd 4 } pmmcCfgline2AccessioCtrb OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " CAIS contributors on Line 2 Port :This register selects the contributors to downstream CAIS/CSF on Port " ::= { pmmctableclientLsd 5 } pmmcCfgline2CdrCtrb OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " CAIS contributors on Line 2 Port :This register selects the contributors to downstream CAIS/CSF on Port " ::= { pmmctableclientLsd 6 } --- ***************************************************** --- LEAF for the table Group startUp --- ***************************************************** pmmcCfgStartUp OBJECT IDENTIFIER ::= { pmmcConfig 2 } --- ***************************************************** --- LEAF for the table 2111 --- ***************************************************** pmmctableclientStartup OBJECT IDENTIFIER ::= { pmmcCfgStartUp 1 } pmmcCfgline1TrscvCtrl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line 1 :This register configures the default initialisation settings on Line 1. " ::= { pmmctableclientStartup 2 } --- ***************************************************** --- LEAF for the table 2191 --- ***************************************************** pmmctablelineStartup OBJECT IDENTIFIER ::= { pmmcCfgStartUp 2 } pmmcCfgline2TrscvCtrl OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Default Settings on Line 2 :This register configures the default initialisation settings on Line 2. " ::= { pmmctablelineStartup 2 } pmmcCfgbitrateSelect OBJECT-TYPE SYNTAX Unsigned32 (0..65536) MAX-ACCESS read-write STATUS current DESCRIPTION " Bitrate selection on Line 1/2 :This OID register configure the bitrate for the client and line interface (0=STS48 : 2,4 to 2,7 Gb/s - 1=1GBE : 1,2 to 1,35 Gb/s - 2=STS12 : 600 to 675 Mb/s - 3=STS3 : 150 to 168 Mb/s - 4=2GFC : 2 to 2,4 Gb/s - 5=1GFC : 1,0 to 1,2 Gb/s - 6=500 to 600 Mb/s - 7=Fast Ethernet : 125 to 150 Mb/s - 8=STS48 + FEC : 2,4-2,7 Gb/s - 9=STS12 + FEC : 600-675 Mb/s - 10=STS3 + FEC : 150-168 Mb/s ). " ::= { pmmctablelineStartup 18 } --- ***************************************************** --- LEAF for the table Group labels --- ***************************************************** pmmcCfgLabels OBJECT IDENTIFIER ::= { pmmcConfig 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmmcCfgLabelclientTable OBJECT-TYPE SYNTAX SEQUENCE OF PmmcCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmmcCfgLabels 1 } pmmcCfgLabelclientEntry OBJECT-TYPE SYNTAX PmmcCfgLabelclientEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmmcCfgLabelclientIndex } ::= { pmmcCfgLabelclientTable 1 } PmmcCfgLabelclientEntry ::= SEQUENCE { pmmcCfgLabelclientIndex INTEGER, pmmcCfgLabelclientPortn DisplayString } pmmcCfgLabelclientIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelclient table " ::= { pmmcCfgLabelclientEntry 1 } pmmcCfgLabelclientPortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the Ports :These registers configures the default initialisation settings of the labels of the ports. " ::= { pmmcCfgLabelclientEntry 3 } --- ***************************************************** --- LEAF for the table NO_VALUE --- ***************************************************** pmmcCfgLabellineTable OBJECT-TYPE SYNTAX SEQUENCE OF PmmcCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " List of Article " ::= { pmmcCfgLabels 2 } pmmcCfgLabellineEntry OBJECT-TYPE SYNTAX PmmcCfgLabellineEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Row definition for the labels table " INDEX { pmmcCfgLabellineIndex } ::= { pmmcCfgLabellineTable 1 } PmmcCfgLabellineEntry ::= SEQUENCE { pmmcCfgLabellineIndex INTEGER, pmmcCfgLabellinePortn DisplayString } pmmcCfgLabellineIndex OBJECT-TYPE SYNTAX INTEGER(0..128) MAX-ACCESS read-only STATUS current DESCRIPTION " Index definition for the labelline table " ::= { pmmcCfgLabellineEntry 1 } pmmcCfgLabellinePortn OBJECT-TYPE SYNTAX DisplayString( SIZE(1..16)) MAX-ACCESS read-write STATUS current DESCRIPTION " Default settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. " ::= { pmmcCfgLabellineEntry 3 } pmmcCfgWriteConfiguration OBJECT-TYPE SYNTAX EkiOnOff MAX-ACCESS read-write STATUS current DESCRIPTION "Write configuration to module:This OID writes the complete configuration to the module" ::= { pmmcConfig 257 } --- ***************************************************** --- TRAP OBJECTS --- ***************************************************** pmmctrapBoardNumber OBJECT-TYPE SYNTAX INTEGER(1..64) MAX-ACCESS read-only STATUS current DESCRIPTION "Last module which generates a trap" ::= { pmmctraps 4 } --- ***************************************************** --- LINE 1 TRAPS --- ***************************************************** pmmcLine1TrapNotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmmcAlmLine1TrscvDdmWarning, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 1 Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmmcAlmLine1TrscvDdmWarning "on", pmmctrapBoardNumber "$2"} --&MESG "DDM Warning appears on Line 1 of PMMC in slot $2 ($A)" DESCRIPTION "Not urgent Line 1 default is activated" ::= { pmmctraps 30 } pmmcLine1TrapNotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmmcAlmLine1TrscvDdmWarning, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 1 Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMMC Line 1 Not Urgent ON"} --&MATCH { pmmcAlmLine1TrscvDdmWarning "on", pmmctrapBoardNumber "$2"} --&MESG "DDM Warning disappears on Line 1 of PMMC in slot $2 ($A)" DESCRIPTION "Not urgent Line 1 default disappeared" ::= { pmmctraps 31 } pmmcLine1TrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmmcAlmLine1TrscvDdmAlm, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 1 Urgent ON" --&ACTIONS { log, major } --&MATCH { pmmcAlmLine1TrscvDdmAlm "on", pmmctrapBoardNumber "$2"} --&MESG "DDM Alarm appears on Line 1 of PMMC in slot $2 ($A)" DESCRIPTION "Urgent Line 1 default is activated" ::= { pmmctraps 32 } pmmcLine1TrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmmcAlmLine1TrscvDdmAlm, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 1 Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMMC Line 1 Urgent ON"} --&MATCH { pmmcAlmLine1TrscvDdmAlm "on", pmmctrapBoardNumber "$2"} --&MESG "DDM Alarm disappears on Line 1 of PMMC in slot $2 ($A)" DESCRIPTION "Urgent Line 1 default disappeared" ::= { pmmctraps 33 } pmmcLine1TrapCritGoesOn NOTIFICATION-TYPE OBJECTS {pmmcAlmLine1Fail, pmmcAlmLine1HwFail, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 1 Fail ON" --&ACTIONS { log, critical } --&MATCH { pmmcAlmLine1Fail "on", pmmcAlmLine1HwFail "*", pmmctrapBoardNumber "$3"} --&MESG "Line Port 1 Down on PMMC in Slot $3 ($A)" --&FILTNAME "PMMC Line 1 HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmmcAlmLine1Fail "*", pmmcAlmLine1HwFail "on", pmmctrapBoardNumber "$3"} --&MESG "Line Port 1 Down on PMMC in Slot $3 ($A)" DESCRIPTION "Critical Line 1 default is activated" ::= { pmmctraps 34 } pmmcLine1TrapCritGoesOff NOTIFICATION-TYPE OBJECTS {pmmcAlmLine1Fail, pmmcAlmLine1HwFail, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 1 Fail OFF" --&ACTIONS { log, normal } --&CLEARS {"PMMC Line 1 Fail ON"} --&MATCH { pmmcAlmLine1Fail "on", pmmcAlmLine1HwFail "*", pmmctrapBoardNumber "$3"} --&MESG "Line Port 1 Up on PMMC in Slot $3 ($A)" --&FILTNAME "PMMC Line 1 HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmmcAlmLine1Fail "*", pmmcAlmLine1HwFail "on", pmmctrapBoardNumber "$3"} --&MESG "Line Port 1 Up on PMMC in Slot $3 ($A)" DESCRIPTION "Critical Line 1 default disappeared" ::= { pmmctraps 35 } --- ***************************************************** --- LINE 2 TRAPS --- ***************************************************** pmmcLine2NotUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmmcAlmLine2TrscvDdmWarning, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 2 Not Urgent ON" --&ACTIONS { log, minor } --&MATCH { pmmcAlmLine2TrscvDdmWarning "on", pmmctrapBoardNumber "$2"} --&MESG "DDM Warning appears on Line 2 of PMMC in slot $2 ($A)" DESCRIPTION "Not urgent Line 2 default is activated" ::= { pmmctraps 40 } pmmcLine2NotUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmmcAlmLine2TrscvDdmWarning, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 2 Not Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMMC Line 2 Not Urgent ON"} --&MATCH { pmmcAlmLine2TrscvDdmWarning "on", pmmctrapBoardNumber "$2"} --&MESG "DDM Warning disappears on Line 2 of PMMC in slot $2 ($A)" DESCRIPTION "Not urgent Line 2 default disappeared" ::= { pmmctraps 41 } pmmcLine2UrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmmcAlmLine2TrscvDdmAlm, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 2 Urgent ON" --&ACTIONS { log, major } --&MATCH { pmmcAlmLine2TrscvDdmAlm "on", pmmctrapBoardNumber "$2"} --&MESG "DDM Alarm appears on Line 2 of PMMC in slot $2 ($A)" DESCRIPTION "Urgent Line 2 default is activated" ::= { pmmctraps 42 } pmmcLine2UrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmmcAlmLine2TrscvDdmAlm, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 2 Urgent OFF" --&ACTIONS { log, normal } --&CLEARS {"PMMC Line 2 Urgent ON"} --&MATCH { pmmcAlmLine2TrscvDdmAlm "on", pmmctrapBoardNumber "$2"} --&MESG "DDM Alarm disappears on Line 2 of PMMC in slot $2 ($A)" DESCRIPTION "Urgent Line 2 default disappeared" ::= { pmmctraps 43 } pmmcLine2CritGoesOn NOTIFICATION-TYPE OBJECTS {pmmcAlmLine2Fail, pmmcAlmLine2HwFail, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 2 Fail ON" --&ACTIONS { log, critical } --&MATCH { pmmcAlmLine2Fail "on", pmmcAlmLine2HwFail "*", pmmctrapBoardNumber "$3"} --&MESG "Line Port 2 Down on PMMC in Slot $3 ($A)" --&FILTNAME "PMMC Line 2 HW Fail ON (Hidden)" --&ACTIONS { info } --&MATCH { pmmcAlmLine2Fail "*", pmmcAlmLine2HwFail "on", pmmctrapBoardNumber "$3"} --&MESG "Line Port 2 Down on PMMC in Slot $3 ($A)" DESCRIPTION "Critical Line 2 default is activated" ::= { pmmctraps 44 } pmmcLine2CritGoesOff NOTIFICATION-TYPE OBJECTS {pmmcAlmLine2Fail, pmmcAlmLine2HwFail, pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Line 2 Fail OFF" --&ACTIONS { log, normal } --&CLEARS {"PMMC Line 2 Fail ON"} --&MATCH { pmmcAlmLine2Fail "on", pmmcAlmLine2HwFail "*", pmmctrapBoardNumber "$3"} --&MESG "Line Port 2 Up on PMMC in Slot $3 ($A)" --&FILTNAME "PMMC Line 2 HW Fail OFF (Hidden)" --&ACTIONS { info } --&MATCH { pmmcAlmLine2Fail "*", pmmcAlmLine2HwFail "on", pmmctrapBoardNumber "$3"} --&MESG "Line Port 2 Up on PMMC in Slot $3 ($A)" DESCRIPTION "Critical Line 2 default disappeared" ::= { pmmctraps 45 } --- ***************************************************** --- HW TRAPS --- ***************************************************** pmmcPowerTrapUrgentGoesOn NOTIFICATION-TYPE OBJECTS {pmmcAlmDefFuseB, pmmcAlmDefFuseA , pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Fuse A Fail ON" --&ACTIONS { log, major } --&MATCH { pmmcAlmDefFuseB "*", pmmcAlmDefFuseA "on", pmmctrapBoardNumber "$3"} --&MESG "Power Input A Fail on PMMC in Slot $3 ($A)" --&FILTNAME "PMMC Fuse B Fail ON" --&ACTIONS { log, major } --&MATCH { pmmcAlmDefFuseB "on", pmmcAlmDefFuseA "*", pmmctrapBoardNumber "$3"} --&MESG "Power Input B Fail on PMMC in Slot $3 ($A)" DESCRIPTION "Urgent power supply default is activated" ::= { pmmctraps 50 } pmmcPowerTrapUrgentGoesOff NOTIFICATION-TYPE OBJECTS {pmmcAlmDefFuseB, pmmcAlmDefFuseA , pmmctrapBoardNumber} STATUS current --&FILTNAME "PMMC Fuse A&B Fail OFF" --&ACTIONS { log, normal} --&CLEARS { "PMMC Fuse A Fail ON", "PMMC Fuse B Fail ON" } --&MATCH { pmmcAlmDefFuseB "on", pmmcAlmDefFuseA "on", pmmctrapBoardNumber "$3"} --&MESG "Power Inputs A and B Present on PMMC in Slot $3 ($A)" DESCRIPTION "Urgent power supply default disappeared" ::= { pmmctraps 51 } END