Files
Observium_CE/mibs/webgraph/WebGraph-AnalogIn-57642-US-MIB

2539 lines
83 KiB
Plaintext

WebGraph-AnalogIn-57642-US-MIB DEFINITIONS ::= BEGIN
-- adama@observium.org fixed typo 2018-10-24
----------------------------------------------------------------
-- Revison: 1.29
----------------------------------------------------------------
-- 22.06.2010 Webio
-- Syntax correction
----------------------------------------------------------------
-- Revison: 1.28
----------------------------------------------------------------
-- 02.12.2008 Webio
-- New Graphics java script base parameter
----------------------------------------------------------------
-- Revison: 1.27
----------------------------------------------------------------
-- 09.11.2006 Webio
-- DHCP enable
----------------------------------------------------------------
-- Revison: 1.26
----------------------------------------------------------------
-- 28.06.2006 New: Community String Trap
--
----------------------------------------------------------------
-- Revison: 1.25
----------------------------------------------------------------
-- 26.07.2005 #57642, WebGraph AnalogIn 2x 0/4..20mA
--
----------------------------------------------------------------
-- Revison: 1.24
----------------------------------------------------------------
-- 26.07.2005 #57642, WebGraph AnalogIn
-- CRON timer function
----------------------------------------------------------------
-- Revison: 1.23
----------------------------------------------------------------
-- 14.07.2005 #57642, WebGraph AnalogIn
-- FTP functions
----------------------------------------------------------------
-- Revison: 1.22
----------------------------------------------------------------
-- 17.05.2005 #57642, WebGraph AnalogIn
-- Trap NMS annotations
----------------------------------------------------------------
-- Revison: 1.21
----------------------------------------------------------------
-- 19.04.2005 #57605, WebGraph Themometer
-- Mail Authentication
----------------------------------------------------------------
-- Revison: 1.20
----------------------------------------------------------------
-- 05.11.2004 #57606, WebGraph Thermo-Hygrometer
-- New: Syslog
--
----------------------------------------------------------------
-- Revison: 1.19
----------------------------------------------------------------
-- 08.09.2004 #57606 WebGraph Thermo-Hygrometer
-- New:
-- wtWebGraphThermHygroAlarmRHMin
-- wtWebGraphThermHygroAlarmRHMax
-- wtWebGraphThermHygroAlarmRHHysteresis
-- wtWebGraphThermHygroPortSensorSelect
-- wtWebGraphThermHygroAlarmDeltaTemp
-- wtWebGraphThermHygroAlarmAHMin
-- wtWebGraphThermHygroAlarmAHMax
----------------------------------------------------------------
-- Revison: 1.18
----------------------------------------------------------------
-- 21.07.2004 #57601/3/4, Webio Anx
-- New:
-- Diagnosis
----------------------------------------------------------------
-- Revison: 1.17
----------------------------------------------------------------
-- 28.06.2004 #57630/1/2, Webio Digital
-- Neu: Puls Mode
----------------------------------------------------------------
-- Revison: 1.16
----------------------------------------------------------------
-- 16.04.2004 New: #57632, Webio Digital EA24x24
--
-- #57630/1, Webio Digital EA12x12
-- New:
-- wtWebioEA12x12InputCounterClear
----------------------------------------------------------------
-- Revison: 1.15
----------------------------------------------------------------
-- 27.02.2004 #57630/1, Webio Digital EA12x12
-- New:
-- Length changed to 32 Bit:
-- wtWebioEA12x12InputValue
-- wtWebioEA12x12OutputValue
-- wtWebioEA12x12LoadControlView
-- wtWebioEA12x12LCShutDownView
-- wtWebioEA12x12SetOutput
-- wtWebioEA12x12AlarmInputTrigger
-- wtWebioEA12x12AlarmOutputTrigger
-- wtWebioEA12x12PortOutputSafetyState
----------------------------------------------------------------
-- Revison: 1.14
----------------------------------------------------------------
-- 16.02.2004 #57630/1, Webio Digital EA12x12
-- New:
-- Text: Location, Contact
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
-- Alarm: ColdStart / WarmStart trigger
--
-- #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New:
-- Alarm Hysteresis
-- Alarm Clear Traps and Mails
----------------------------------------------------------------
-- Revison: 1.13
----------------------------------------------------------------
-- 05.02.2004 #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New:
-- Text: Location, Contact
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
-- Alarm: ColdStart / WarmStart trigger
----------------------------------------------------------------
-- Revison: 1.12
----------------------------------------------------------------
-- 05.11.2003 #57601, 1xWebThermometer
-- #57603, 2xWebThermometer
-- #57604, 8xWebThermometer
-- New features:
-- Mail : Option CSV attachment
-- Port : Offset calibration
-- Alarm : TCP Client mode
----------------------------------------------------------------
-- Revison: 1.11
----------------------------------------------------------------
-- 28.10.2003 #57630/1, Webio Digital EA12x12
-- New features:
-- Alarm : TCP Client mode
-- Inputs: Puls filter
----------------------------------------------------------------
-- Revison: 1.10
----------------------------------------------------------------
-- 22.07.2003 #57630, Webio Digital EA12x12
-- New navigation tree, new binary modes
--
----------------------------------------------------------------
-- Revison: 1.09
----------------------------------------------------------------
-- 24.03.2003 Trap Enterprise (Type 1, 2) corrected
----------------------------------------------------------------
-- Revison: 1.08
----------------------------------------------------------------
-- 04.03.2003 reconciled the language versions DE/US
----------------------------------------------------------------
-- Revison: 1.07
----------------------------------------------------------------
-- 25.02.2003 Correction: wtWebioEA12x12LoadControl
----------------------------------------------------------------
-- Revison: 1.06
----------------------------------------------------------------
-- 24.02.2003 New:
-- #57630, Webio EA12x12, LoadControl Group
-- Correction: Trap variable names
----------------------------------------------------------------
-- Revison: 1.05
----------------------------------------------------------------
-- 21.01.2003 New:
-- #57630, Webio EA12x12
----------------------------------------------------------------
-- Revison: 1.04
----------------------------------------------------------------
-- 02.01.2003 New:
-- #57601, 1xWebThermometer
-- #57603, 2xWebThermometer, 8 alarms
----------------------------------------------------------------
-- Revison: 1.03
----------------------------------------------------------------
-- 21.11.2002 New:
-- #57604, 2xWebThermometer, BOOTP, StartupSite
-- #57603, 8xWebThermometer, BOOTP, StartupSite
----------------------------------------------------------------
-- Revison: 1.02
----------------------------------------------------------------
-- 26.07.2002 New:
-- #57604, 2xWebThermometer
-- #57603, 8xWebThermometer
--
IMPORTS
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
DisplayString, PhysAddress FROM RFC1213-MIB
enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
-- IpAddress ::=
-- [APPLICATION 0]
-- IMPLICIT OCTET STRING (SIZE (4))
-- Counter ::=
-- [APPLICATION 1]
-- IMPLICIT INTEGER (0..4294967295)
-- Gauge ::=
-- [APPLICATION 2]
-- IMPLICIT INTEGER (0..4294967295)
-- TimeTicks ::=
-- [APPLICATION 3]
-- IMPLICIT INTEGER (0..4294967295)
-- DisplayString ::= OCTET STRING
-- PhysAddress ::= OCTET STRING
-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
-- privat OBJECT IDENTIFIER ::= { internet 4 }
-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
-- Wiesemann & Theis Com-Server MIB
wut OBJECT IDENTIFIER ::= { enterprises 5040 }
wtComServer OBJECT IDENTIFIER ::= { wut 1 }
wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
-- wtWebGraph Tree
wtWebGraphAnalogIn57642 OBJECT IDENTIFIER ::= { wtWebio 11 }
-- wtWebGraphAnalogIn57642 Tree
wtWebGraphAnalogIn57642Inventory OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642 1 }
wtWebGraphAnalogIn57642SessCntrl OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642 2 }
wtWebGraphAnalogIn57642Config OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642 3 }
wtWebGraphAnalogIn57642Diag OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642 4 }
-- wtWebGraphAnalogIn57642Config Tree
wtWebGraphAnalogIn57642Device OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Config 1 }
wtWebGraphAnalogIn57642Ports OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Config 2 }
wtWebGraphAnalogIn57642Manufact OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Config 3 }
-- wtWebGraphAnalogIn57642Device Tree
wtWebGraphAnalogIn57642Text OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 1 }
wtWebGraphAnalogIn57642TimeDate OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 2 }
wtWebGraphAnalogIn57642Basic OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 3 }
wtWebGraphAnalogIn57642Datalogger OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 4 }
wtWebGraphAnalogIn57642Alarm OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 5 }
wtWebGraphAnalogIn57642Graphics OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 6 }
-- wtWebGraphAnalogIn57642TimeDate Tree
wtWebGraphAnalogIn57642TimeZone OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642TimeDate 1 }
wtWebGraphAnalogIn57642TimeServer OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642TimeDate 2 }
wtWebGraphAnalogIn57642DeviceClock OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642TimeDate 3 }
-- wtWebGraphAnalogIn57642Basic Tree
wtWebGraphAnalogIn57642Network OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 1 }
wtWebGraphAnalogIn57642HTTP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 2 }
wtWebGraphAnalogIn57642Mail OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 3 }
wtWebGraphAnalogIn57642SNMP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 4 }
wtWebGraphAnalogIn57642UDP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 5 }
wtWebGraphAnalogIn57642Syslog OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 6 }
wtWebGraphAnalogIn57642FTP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 7 }
-- wtWebGraphAnalogIn57642Graphics Tree
wtWebGraphAnalogIn57642GraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Graphics 1 }
wtWebGraphAnalogIn57642GraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Graphics 2 }
wtWebGraphAnalogIn57642GraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Graphics 3 }
-- wtWebGraphAnalogIn57642Inventory Group
------------------------
wtWebGraphAnalogIn57642Sensors OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of sensors"
::= { wtWebGraphAnalogIn57642Inventory 1 }
-- Interface Table
wtWebGraphAnalogIn57642SensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensors."
::= { wtWebGraphAnalogIn57642Inventory 2 }
wtWebGraphAnalogIn57642SensorEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57642SensorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensor numbers."
INDEX { wtWebGraphAnalogIn57642SensorNo }
::= { wtWebGraphAnalogIn57642SensorTable 1 }
WtWebGraphAnalogIn57642SensorEntry ::= SEQUENCE {
wtWebGraphAnalogIn57642SensorNo INTEGER
}
wtWebGraphAnalogIn57642SensorNo OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Sensor number."
::= { wtWebGraphAnalogIn57642SensorEntry 1 }
-- wtWebGraphAnalogIn57642Values Table
wtWebGraphAnalogIn57642ValuesTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642ValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of measurement values corresponding to the channel numbers."
::= { wtWebGraphAnalogIn57642Inventory 3 }
wtWebGraphAnalogIn57642ValuesEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57642ValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Measurement values of the sensors."
INDEX { wtWebGraphAnalogIn57642SensorNo }
::= { wtWebGraphAnalogIn57642ValuesTable 1 }
WtWebGraphAnalogIn57642ValuesEntry ::= SEQUENCE{
wtWebGraphAnalogIn57642Values OCTET STRING
}
wtWebGraphAnalogIn57642Values OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (5))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Measurement value of the sensor, ASCII, 7 characters in length."
::= { wtWebGraphAnalogIn57642ValuesEntry 1 }
-- wtWebGraphAnalogIn57642BinaryValues Table
wtWebGraphAnalogIn57642BinaryValuesTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642BinaryValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of binary measurement values corresponding to the channel numbers."
::= { wtWebGraphAnalogIn57642Inventory 4 }
wtWebGraphAnalogIn57642BinaryValuesEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57642BinaryValuesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Binary measurement values of the sensors."
INDEX { wtWebGraphAnalogIn57642SensorNo }
::= { wtWebGraphAnalogIn57642BinaryValuesTable 1 }
WtWebGraphAnalogIn57642BinaryValuesEntry ::= SEQUENCE{
wtWebGraphAnalogIn57642BinaryValues INTEGER
}
wtWebGraphAnalogIn57642BinaryValues OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent,
signed number, 0x4FFF6 indicates an
invalid measured value."
::= { wtWebGraphAnalogIn57642BinaryValuesEntry 1 }
-- wtWebGraphAnalogIn57642SessCntrl Group
--------------------------------
wtWebGraphAnalogIn57642SessCntrlPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Entering this password opens a session which is ended by writing a 1 to
wtWebGraphAnalogIn57642SessCntrlLogout. When read this variable provides a string of
length zero."
::= { wtWebGraphAnalogIn57642SessCntrl 1 }
wtWebGraphAnalogIn57642SessCntrlConfigMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57642SessCntrl-NoSession(0),
wtWebGraphAnalogIn57642SessCntrl-Session(1)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"When the device is in SNMP configuration mode, the value 1 is
returned, otherwise 0. If the read value is 0 even though the
password was written, the device is already in config mode and the
variables can only be read."
::= { wtWebGraphAnalogIn57642SessCntrl 2 }
wtWebGraphAnalogIn57642SessCntrlLogout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the device is in configuration mode and the session was opened by
this SNMP Manager, writing a 1 to this variable will end the session
and all parameters are stored.
Writing a 2 discards all entries again.
When read this variable provides the value 0."
::= { wtWebGraphAnalogIn57642SessCntrl 3 }
wtWebGraphAnalogIn57642SessCntrlAdminPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with administrator rights.
It can only be changed by the administrator. If no password was assigned,
the valid password is public."
::= { wtWebGraphAnalogIn57642SessCntrl 4 }
wtWebGraphAnalogIn57642SessCntrlConfigPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This password protects access to the variables with configurator rights. It can
be changed by the administrator and by the configurator. If no password was assigned,
the valid password is public. When read this variable provides a null-pointer."
::= { wtWebGraphAnalogIn57642SessCntrl 5 }
-- wtWebGraphAnalogIn57642Text Group
------------------------
wtWebGraphAnalogIn57642DeviceName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the Webio, which is user definable."
::= { wtWebGraphAnalogIn57642Text 1 }
wtWebGraphAnalogIn57642DeviceText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the Webio, which is user definable."
::= { wtWebGraphAnalogIn57642Text 2 }
wtWebGraphAnalogIn57642DeviceLocation OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the location of the Webio, which is user definable."
::= { wtWebGraphAnalogIn57642Text 3 }
wtWebGraphAnalogIn57642DeviceContact OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Contact address of the system operator of the Webio, which is user definable."
::= { wtWebGraphAnalogIn57642Text 4 }
-- wtWebGraphAnalogIn57642TimeZone Group
----------------------------
wtWebGraphAnalogIn57642TzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours for the time zone (winter time) with respect to UTC."
::= { wtWebGraphAnalogIn57642TimeZone 1 }
wtWebGraphAnalogIn57642TzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes for the time zone (winter time) with respect to UTC."
::= { wtWebGraphAnalogIn57642TimeZone 2 }
wtWebGraphAnalogIn57642TzEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Timezone"
::= { wtWebGraphAnalogIn57642TimeZone 3 }
wtWebGraphAnalogIn57642StTzOffsetHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset hours of the time zone (summer time) with respect to UTC."
::= { wtWebGraphAnalogIn57642TimeZone 4 }
wtWebGraphAnalogIn57642StTzOffsetMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset minutes of the time zone (summer time) with respect to UTC."
::= { wtWebGraphAnalogIn57642TimeZone 5 }
wtWebGraphAnalogIn57642StTzEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Summertime"
::= { wtWebGraphAnalogIn57642TimeZone 6 }
wtWebGraphAnalogIn57642StTzStartMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57642StartMonth-January(1),
wtWebGraphAnalogIn57642StartMonth-February(2),
wtWebGraphAnalogIn57642StartMonth-March(3),
wtWebGraphAnalogIn57642StartMonth-April(4),
wtWebGraphAnalogIn57642StartMonth-May(5),
wtWebGraphAnalogIn57642StartMonth-June(6),
wtWebGraphAnalogIn57642StartMonth-July(7),
wtWebGraphAnalogIn57642StartMonth-August(8),
wtWebGraphAnalogIn57642StartMonth-September(9),
wtWebGraphAnalogIn57642StartMonth-October(10),
wtWebGraphAnalogIn57642StartMonth-November(11),
wtWebGraphAnalogIn57642StartMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from winter time to summer time."
::= { wtWebGraphAnalogIn57642TimeZone 7 }
wtWebGraphAnalogIn57642StTzStartMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57642StartMode-first(1),
wtWebGraphAnalogIn57642StartMode-second(2),
wtWebGraphAnalogIn57642StartMode-third(3),
wtWebGraphAnalogIn57642StartMode-fourth(4),
wtWebGraphAnalogIn57642StartMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the day of the week for which the change is made from winter time to summer time."
::= { wtWebGraphAnalogIn57642TimeZone 8 }
wtWebGraphAnalogIn57642StTzStartWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57642StartWday-Sunday(1),
wtWebGraphAnalogIn57642StartWday-Monday(2),
wtWebGraphAnalogIn57642StartWday-Tuesday(3),
wtWebGraphAnalogIn57642StartWday-Thursday(4),
wtWebGraphAnalogIn57642StartWday-Wednesday(5),
wtWebGraphAnalogIn57642StartWday-Friday(6),
wtWebGraphAnalogIn57642StartWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from winter time to summer time"
::= { wtWebGraphAnalogIn57642TimeZone 9 }
wtWebGraphAnalogIn57642StTzStartHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebGraphAnalogIn57642TimeZone 10 }
wtWebGraphAnalogIn57642StTzStartMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute in which the time zone is changed from winter to summer time with
respect to UTC."
::= { wtWebGraphAnalogIn57642TimeZone 11 }
wtWebGraphAnalogIn57642StTzStopMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57642StopMonth-January(1),
wtWebGraphAnalogIn57642StopMonth-February(2),
wtWebGraphAnalogIn57642StopMonth-March(3),
wtWebGraphAnalogIn57642StopMonth-April(4),
wtWebGraphAnalogIn57642StopMonth-May(5),
wtWebGraphAnalogIn57642StopMonth-June(6),
wtWebGraphAnalogIn57642StopMonth-July(7),
wtWebGraphAnalogIn57642StopMonth-August(8),
wtWebGraphAnalogIn57642StopMonth-September(9),
wtWebGraphAnalogIn57642StopMonth-October(10),
wtWebGraphAnalogIn57642StopMonth-November(11),
wtWebGraphAnalogIn57642StopMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Month in which the change is made from summer time to winter time."
::= { wtWebGraphAnalogIn57642TimeZone 12 }
wtWebGraphAnalogIn57642StTzStopMode OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57642StopMode-first(1),
wtWebGraphAnalogIn57642StopMode-second(2),
wtWebGraphAnalogIn57642StopMode-third(3),
wtWebGraphAnalogIn57642StopMode-fourth(4),
wtWebGraphAnalogIn57642StopMode-last(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode of the week day on which the change is made from summer time to winter time."
::= { wtWebGraphAnalogIn57642TimeZone 13 }
wtWebGraphAnalogIn57642StTzStopWday OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57642StopWday-Sunday(1),
wtWebGraphAnalogIn57642StopWday-Monday(2),
wtWebGraphAnalogIn57642StopWday-Tuesday(3),
wtWebGraphAnalogIn57642StopWday-Thursday(4),
wtWebGraphAnalogIn57642StopWday-Wednesday(5),
wtWebGraphAnalogIn57642StopWday-Friday(6),
wtWebGraphAnalogIn57642StopWday-Saturday(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Day of the week on which the change is made from summer time to winter time."
::= { wtWebGraphAnalogIn57642TimeZone 14 }
wtWebGraphAnalogIn57642StTzStopHrs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hour at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebGraphAnalogIn57642TimeZone 15 }
wtWebGraphAnalogIn57642StTzStopMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minute at which the time zone is changed from summer to winter time with
respect to UTC."
::= { wtWebGraphAnalogIn57642TimeZone 16 }
-- wtWebGraphAnalogIn57642TimeServer Group
----------------------------
wtWebGraphAnalogIn57642TimeServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 1st time server in ASCII"
::= { wtWebGraphAnalogIn57642TimeServer 1 }
wtWebGraphAnalogIn57642TimeServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address or name of the 2nd time server in ASCII"
::= { wtWebGraphAnalogIn57642TimeServer 2 }
wtWebGraphAnalogIn57642TsEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Apply Time Server"
::= { wtWebGraphAnalogIn57642TimeServer 3 }
wtWebGraphAnalogIn57642TsSyncTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Daily synchronisation time with the time server (hour: 0-23)."
::= { wtWebGraphAnalogIn57642TimeServer 4 }
-- wtWebGraphAnalogIn57642DeviceClock Group
----------------------------
wtWebGraphAnalogIn57642ClockHrs OBJECT-TYPE
SYNTAX INTEGER (0..23)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock hours taking into account the time zone settings."
::= { wtWebGraphAnalogIn57642DeviceClock 1 }
wtWebGraphAnalogIn57642ClockMin OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock minutes taking into account the time zone settings."
::= { wtWebGraphAnalogIn57642DeviceClock 2 }
wtWebGraphAnalogIn57642ClockDay OBJECT-TYPE
SYNTAX INTEGER (1..31)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Day of the month, taking into account the time zone settings."
::= { wtWebGraphAnalogIn57642DeviceClock 3 }
wtWebGraphAnalogIn57642ClockMonth OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57642ClockMonth-January(1),
wtWebGraphAnalogIn57642ClockMonth-February(2),
wtWebGraphAnalogIn57642ClockMonth-March(3),
wtWebGraphAnalogIn57642ClockMonth-April(4),
wtWebGraphAnalogIn57642ClockMonth-May(5),
wtWebGraphAnalogIn57642ClockMonth-June(6),
wtWebGraphAnalogIn57642ClockMonth-July(7),
wtWebGraphAnalogIn57642ClockMonth-August(8),
wtWebGraphAnalogIn57642ClockMonth-September(9),
wtWebGraphAnalogIn57642ClockMonth-October(10),
wtWebGraphAnalogIn57642ClockMonth-November(11),
wtWebGraphAnalogIn57642ClockMonth-December(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Month, taking into account the time zone settings."
::= { wtWebGraphAnalogIn57642DeviceClock 4 }
wtWebGraphAnalogIn57642ClockYear OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date: Year, taking into account the time zone settings."
::= { wtWebGraphAnalogIn57642DeviceClock 5 }
-- wtWebGraphAnalogIn57642Network Group
------------------------
wtWebGraphAnalogIn57642IpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the Webio"
::= { wtWebGraphAnalogIn57642Network 1 }
wtWebGraphAnalogIn57642SubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subnet mask of the Webio"
::= { wtWebGraphAnalogIn57642Network 2 }
wtWebGraphAnalogIn57642Gateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway of the Webio"
::= { wtWebGraphAnalogIn57642Network 3 }
wtWebGraphAnalogIn57642DnsServer1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 1st DNS server in ASCII"
::= { wtWebGraphAnalogIn57642Network 4 }
wtWebGraphAnalogIn57642DnsServer2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the 2nd DNS server in ASCII"
::= { wtWebGraphAnalogIn57642Network 5 }
wtWebGraphAnalogIn57642AddConfig OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Additional configuration (1=ON):
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: DHCP disable
Bit 0: BOOTP disable
"
::= { wtWebGraphAnalogIn57642Network 6 }
-- wtWebGraphAnalogIn57642HTTP Group
--------------------------------
wtWebGraphAnalogIn57642Startup OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded start page:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1: Index.htm
Bit 2: Home.htm
Bit 3: User.htm
Only one page may be selected at a time."
::= { wtWebGraphAnalogIn57642HTTP 1 }
wtWebGraphAnalogIn57642GetHeaderEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If these bits are set, every answer of a short form GET question will be lead
by the IP-address and name of the device and/or a HTTP header:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-6: unused
Bit 1 : GET HTTP enable
Bit 0 : GET Header enable"
::= { wtWebGraphAnalogIn57642HTTP 2 }
wtWebGraphAnalogIn57642HttpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Definition of the standard HTML port (Default: 80)."
::= { wtWebGraphAnalogIn57642HTTP 3 }
-- wtWebGraphAnalogIn57642Mail Group
--------------------------------
wtWebGraphAnalogIn57642MailAdName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Device name for mail administration."
::= { wtWebGraphAnalogIn57642Mail 1 }
wtWebGraphAnalogIn57642MailReply OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reply address for the mail server."
::= { wtWebGraphAnalogIn57642Mail 2 }
wtWebGraphAnalogIn57642MailServer OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the mail server."
::= { wtWebGraphAnalogIn57642Mail 3 }
wtWebioAn1MailEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this bit to enable the sending of mails:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Mail enable"
::= { wtWebGraphAnalogIn57642Mail 4 }
wtWebGraphAnalogIn57642MailAuthentication OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selection of the authentication modi:
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
Bit 0 corresponds to the LSB.
OCTET 1: unused
OCTET 2: unused
OCTET 3: unused
OCTET 4: Bit 3-7: unused
Bit 2 : POP3 before SMTP
Bit 1 : ESMTP, authentication
Bit 0 : SMTP, no authentication"
::= { wtWebGraphAnalogIn57642Mail 5 }
wtWebGraphAnalogIn57642MailAuthUser OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the user to be authenticated."
::= { wtWebGraphAnalogIn57642Mail 6 }
wtWebGraphAnalogIn57642MailAuthPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Authentication password."
::= { wtWebGraphAnalogIn57642Mail 7 }
wtWebGraphAnalogIn57642MailPop3Server OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or Ip-address of the POP3 Servers."
::= { wtWebGraphAnalogIn57642Mail 8 }
-- wtWebGraphAnalogIn57642SNMP Group
--------------------------------
wtWebGraphAnalogIn57642SnmpCommunityStringRead OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read only"
::= { wtWebGraphAnalogIn57642SNMP 1 }
wtWebGraphAnalogIn57642SnmpCommunityStringReadWrite OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string read / write"
::= { wtWebGraphAnalogIn57642SNMP 2 }
wtWebGraphAnalogIn57642SystemTrapManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the system trap."
::= { wtWebGraphAnalogIn57642SNMP 3 }
wtWebGraphAnalogIn57642SystemTrapEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57642SNMP 4 }
wtWebGraphAnalogIn57642SnmpEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set bit 0 to enable SNMP.
If disabled, the device did not respond to any SNMP requests.
Bit 1 decided wether the community string of read operations
is compared with the system password or not:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : SNMP enable"
::= { wtWebGraphAnalogIn57642SNMP 5 }
wtWebGraphAnalogIn57642SnmpCommunityStringTrap OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Community string send within traps."
::= { wtWebGraphAnalogIn57642SNMP 6 }
-- wtWebGraphAnalogIn57642UDP Group
--------------------------------
wtWebGraphAnalogIn57642UdpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
port number must be unique within the device."
::= { wtWebGraphAnalogIn57642UDP 1 }
wtWebGraphAnalogIn57642UdpEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this bit to enable UDP support:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : UDP enable"
::= { wtWebGraphAnalogIn57642UDP 2 }
-- wtWebGraphAnalogIn57642Syslog Group
--------------------------------
wtWebGraphAnalogIn57642SyslogServerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
::= { wtWebGraphAnalogIn57642Syslog 1 }
wtWebGraphAnalogIn57642SyslogServerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Portnumber of the Syslog servers, default 514."
::= { wtWebGraphAnalogIn57642Syslog 2 }
wtWebGraphAnalogIn57642SyslogSystemMessagesEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: ColdStart
Bit 1: WarmStart
Bit 2: Diag Messages
Bit 3-7: unused"
::= { wtWebGraphAnalogIn57642Syslog 3 }
wtWebGraphAnalogIn57642SyslogEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set bit 0to enable Syslog:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Syslog enable"
::= { wtWebGraphAnalogIn57642Syslog 4 }
-- wtWebGraphAnalogIn57642FTP Group
--------------------------------
wtWebGraphAnalogIn57642FTPServerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the FTP server, which accepts the FTP messages."
::= { wtWebGraphAnalogIn57642FTP 1 }
wtWebGraphAnalogIn57642FTPServerControlPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Portnumber of the control port of the FTP server, default 21."
::= { wtWebGraphAnalogIn57642FTP 2 }
wtWebGraphAnalogIn57642FTPUserName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP Loggin: user name."
::= { wtWebGraphAnalogIn57642FTP 3 }
wtWebGraphAnalogIn57642FTPPassword OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP Loggin: user password."
::= { wtWebGraphAnalogIn57642FTP 4 }
wtWebGraphAnalogIn57642FTPAccount OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP Loggin: name of account."
::= { wtWebGraphAnalogIn57642FTP 5 }
wtWebGraphAnalogIn57642FTPOption OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bit 0 switches the FTP Server in Passiv-Mode,
the Client controls the data connection on its own:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : PASV enable"
::= { wtWebGraphAnalogIn57642FTP 6 }
wtWebGraphAnalogIn57642FTPEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set Bit 0 to enable FTP:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : FTP enable"
::= { wtWebGraphAnalogIn57642FTP 7 }
-- wtWebGraphAnalogIn57642Datalogger Group
--------------------------------
wtWebGraphAnalogIn57642LoggerTimebase OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57642Datalogger-1Min(1),
wtWebGraphAnalogIn57642Datalogger-5Min(2),
wtWebGraphAnalogIn57642Datalogger-15Min(3),
wtWebGraphAnalogIn57642Datalogger-60Min(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time base of the data logger"
::= { wtWebGraphAnalogIn57642Datalogger 1 }
wtWebGraphAnalogIn57642LoggerSensorSel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57642Datalogger 2 }
wtWebGraphAnalogIn57642DisplaySensorSel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded sensor selection:
only selected sensors will be shown in the graphical presentation:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57642Datalogger 3 }
-- Graph Sensor Color Table
wtWebGraphAnalogIn57642SensorColorTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642SensorColorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensor colors for the praphical presentation."
::= { wtWebGraphAnalogIn57642Datalogger 4 }
wtWebGraphAnalogIn57642SensorColorEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57642SensorColorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Index numbers of the sensors."
INDEX { wtWebGraphAnalogIn57642SensorNo }
::= { wtWebGraphAnalogIn57642SensorColorTable 1 }
WtWebGraphAnalogIn57642SensorColorEntry ::= SEQUENCE {
wtWebGraphAnalogIn57642SensorColor OCTET STRING
}
wtWebGraphAnalogIn57642SensorColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Color of the sensors at the praphical presention."
::= { wtWebGraphAnalogIn57642SensorColorEntry 1 }
wtWebGraphAnalogIn57642AutoScaleEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If bit 0 is set, vertical auto scale is enabled:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 1-7: unused
Bit 0 : Auto Scale enable"
::= { wtWebGraphAnalogIn57642Datalogger 5 }
wtWebGraphAnalogIn57642VerticalUpperLimit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value defines the maximum temperature shown in the graphical presentation,
if no auto scaling is selected.
Temperature in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57642Datalogger 6 }
wtWebGraphAnalogIn57642VerticalLowerLimit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value defines the minimum temperature shown in the graphical presentation,
if no auto scaling is selected.
Temperature in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57642Datalogger 7 }
wtWebGraphAnalogIn57642HorizontalZoom OBJECT-TYPE
SYNTAX INTEGER {
wtWebGraphAnalogIn57642Zoom-25min(1),
wtWebGraphAnalogIn57642Zoom-75min(2),
wtWebGraphAnalogIn57642Zoom-5hrs(3),
wtWebGraphAnalogIn57642Zoom-30hrs(4),
wtWebGraphAnalogIn57642Zoom-5days(5),
wtWebGraphAnalogIn57642Zoom-25days(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the default zoom stage, if no auto scaling is selected."
::= { wtWebGraphAnalogIn57642Datalogger 8 }
-- wtWebGraphAnalogIn57642Alarm Group
----------------------------
wtWebGraphAnalogIn57642AlarmCount OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of independent alarms."
::= { wtWebGraphAnalogIn57642Alarm 1 }
-- Alarm Interface Table
wtWebGraphAnalogIn57642AlarmIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of alarm indices."
::= { wtWebGraphAnalogIn57642Alarm 2 }
wtWebGraphAnalogIn57642AlarmIfEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57642AlarmIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Numbers of the alarms."
INDEX { wtWebGraphAnalogIn57642AlarmNo }
::= { wtWebGraphAnalogIn57642AlarmIfTable 1 }
WtWebGraphAnalogIn57642AlarmIfEntry ::= SEQUENCE {
wtWebGraphAnalogIn57642AlarmNo INTEGER
}
wtWebGraphAnalogIn57642AlarmNo OBJECT-TYPE
SYNTAX INTEGER (1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Alarm number."
::= { wtWebGraphAnalogIn57642AlarmIfEntry 1 }
-- Alarm Table
wtWebGraphAnalogIn57642AlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the alarm number."
::= { wtWebGraphAnalogIn57642Alarm 3 }
wtWebGraphAnalogIn57642AlarmEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57642AlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Alarm parameters of the individual alarms."
INDEX { wtWebGraphAnalogIn57642AlarmNo }
::= { wtWebGraphAnalogIn57642AlarmTable 1 }
WtWebGraphAnalogIn57642AlarmEntry ::= SEQUENCE {
wtWebGraphAnalogIn57642AlarmTrigger OCTET STRING,
wtWebGraphAnalogIn57642AlarmMin OCTET STRING,
wtWebGraphAnalogIn57642AlarmMax OCTET STRING,
wtWebGraphAnalogIn57642AlarmHysteresis OCTET STRING,
wtWebGraphAnalogIn57642AlarmDelay OCTET STRING,
wtWebGraphAnalogIn57642AlarmInterval OCTET STRING,
wtWebGraphAnalogIn57642AlarmEnable OCTET STRING,
wtWebGraphAnalogIn57642AlarmEMailAddr OCTET STRING,
wtWebGraphAnalogIn57642AlarmMailSubject OCTET STRING,
wtWebGraphAnalogIn57642AlarmMailText OCTET STRING,
wtWebGraphAnalogIn57642AlarmManagerIP OCTET STRING,
wtWebGraphAnalogIn57642AlarmTrapText OCTET STRING,
wtWebGraphAnalogIn57642AlarmMailOptions OCTET STRING,
wtWebGraphAnalogIn57642AlarmTcpIpAddr OCTET STRING,
wtWebGraphAnalogIn57642AlarmTcpPort INTEGER,
wtWebGraphAnalogIn57642AlarmTcpText OCTET STRING,
wtWebGraphAnalogIn57642AlarmClearMailSubject OCTET STRING,
wtWebGraphAnalogIn57642AlarmClearMailText OCTET STRING,
wtWebGraphAnalogIn57642AlarmClearTrapText OCTET STRING,
wtWebGraphAnalogIn57642AlarmClearTcpText OCTET STRING,
wtWebGraphAnalogIn57642Alarm2Min OCTET STRING,
wtWebGraphAnalogIn57642Alarm2Max OCTET STRING,
wtWebGraphAnalogIn57642Alarm2Hysteresis OCTET STRING,
wtWebGraphAnalogIn57642AlarmSyslogIpAddr OCTET STRING,
wtWebGraphAnalogIn57642AlarmSyslogPort INTEGER,
wtWebGraphAnalogIn57642AlarmSyslogText OCTET STRING,
wtWebGraphAnalogIn57642AlarmSyslogClearText OCTET STRING,
wtWebGraphAnalogIn57642AlarmFtpDataPort OCTET STRING,
wtWebGraphAnalogIn57642AlarmFtpFileName OCTET STRING,
wtWebGraphAnalogIn57642AlarmFtpText OCTET STRING,
wtWebGraphAnalogIn57642AlarmFtpClearText OCTET STRING,
wtWebGraphAnalogIn57642AlarmFtpOption OCTET STRING,
wtWebGraphAnalogIn57642AlarmTimerCron OCTET STRING
}
wtWebGraphAnalogIn57642AlarmTrigger OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded trigger conditions:
Octet 1: unused
Octet 2: unused
Octet 3:
Bit 0: Timer
Bit 1: ColdStart
Bit 2: WarmStart
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57642AlarmEntry 1 }
wtWebGraphAnalogIn57642AlarmMin OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum temperature in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57642AlarmEntry 2 }
wtWebGraphAnalogIn57642AlarmMax OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum temperature in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57642AlarmEntry 3 }
wtWebGraphAnalogIn57642AlarmHysteresis OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
, in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57642AlarmEntry 4 }
wtWebGraphAnalogIn57642AlarmDelay OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm will be delayed by setting this time while stable alarm
condition occur (time in minutes)."
::= { wtWebGraphAnalogIn57642AlarmEntry 5 }
wtWebGraphAnalogIn57642AlarmInterval OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Send interval for alarm messages."
::= { wtWebGraphAnalogIn57642AlarmEntry 6 }
wtWebGraphAnalogIn57642AlarmEnable OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded alarm enable:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Mail Enable
Bit 1: SNMP Trap enable
Bit 2: TCP Client enable"
::= { wtWebGraphAnalogIn57642AlarmEntry 7 }
wtWebGraphAnalogIn57642AlarmEMailAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"E-Mail address for sending the alarm mail to."
::= { wtWebGraphAnalogIn57642AlarmEntry 8 }
wtWebGraphAnalogIn57642AlarmMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm mail."
::= { wtWebGraphAnalogIn57642AlarmEntry 9 }
wtWebGraphAnalogIn57642AlarmMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time."
::= { wtWebGraphAnalogIn57642AlarmEntry 10 }
wtWebGraphAnalogIn57642AlarmManagerIP OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the SNMP Manager which accepts the trap."
::= { wtWebGraphAnalogIn57642AlarmEntry 11 }
wtWebGraphAnalogIn57642AlarmTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebGraphAnalogIn57642AlarmEntry 12 }
wtWebGraphAnalogIn57642AlarmMailOptions OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Attach Thermo.csv Enable
Bit 1 : CSV-Data_since_last_report
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57642AlarmEntry 13 }
wtWebGraphAnalogIn57642AlarmTcpIpAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name or IP address of the TCP server which accepts the trap."
::= { wtWebGraphAnalogIn57642AlarmEntry 14 }
wtWebGraphAnalogIn57642AlarmTcpPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the TCP server which accepts the trap."
::= { wtWebGraphAnalogIn57642AlarmEntry 15 }
wtWebGraphAnalogIn57642AlarmTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebGraphAnalogIn57642AlarmEntry 16 }
wtWebGraphAnalogIn57642AlarmClearMailSubject OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Subject line for alarm clear mail."
::= { wtWebGraphAnalogIn57642AlarmEntry 17 }
wtWebGraphAnalogIn57642AlarmClearMailText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm clear mail text: <Tn> provides the current temperature; n = 1..8.
<Z> provides the current time."
::= { wtWebGraphAnalogIn57642AlarmEntry 18 }
wtWebGraphAnalogIn57642AlarmClearTrapText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the trap body."
::= { wtWebGraphAnalogIn57642AlarmEntry 19 }
wtWebGraphAnalogIn57642AlarmClearTcpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This text is sent in the TCP trap body."
::= { wtWebGraphAnalogIn57642AlarmEntry 20 }
wtWebGraphAnalogIn57642Alarm2Min OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum rel. Humidity in percent with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57642AlarmEntry 21 }
wtWebGraphAnalogIn57642Alarm2Max OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum rel.Humidity in percent with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57642AlarmEntry 22 }
wtWebGraphAnalogIn57642Alarm2Hysteresis OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Hysterese rel. Humidity in percent with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57642AlarmEntry 23 }
wtWebGraphAnalogIn57642AlarmSyslogIpAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the syslog server to which the Webio device should send syslog messages."
::= { wtWebGraphAnalogIn57642AlarmEntry 24 }
wtWebGraphAnalogIn57642AlarmSyslogPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number of the syslog server to which the Webio device should send syslog messages."
::= { wtWebGraphAnalogIn57642AlarmEntry 25 }
wtWebGraphAnalogIn57642AlarmSyslogText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body."
::= { wtWebGraphAnalogIn57642AlarmEntry 26 }
wtWebGraphAnalogIn57642AlarmSyslogClearText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
This text appears in the following syslog message body of a alarm clear message."
::= { wtWebGraphAnalogIn57642AlarmEntry 27 }
wtWebGraphAnalogIn57642AlarmFtpDataPort OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
::= { wtWebGraphAnalogIn57642AlarmEntry 28 }
wtWebGraphAnalogIn57642AlarmFtpFileName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the file including path informations."
::= { wtWebGraphAnalogIn57642AlarmEntry 29 }
wtWebGraphAnalogIn57642AlarmFtpText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Message text to store on the FTP server."
::= { wtWebGraphAnalogIn57642AlarmEntry 30 }
wtWebGraphAnalogIn57642AlarmFtpClearText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Alarm clear message to store on the FTP server."
::= { wtWebGraphAnalogIn57642AlarmEntry 31 }
wtWebGraphAnalogIn57642AlarmFtpOption OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options, select only one option at the same time:
STORE = replace file
APPEND = append message at the end of the file
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : STORE
Bit 1 : APPEND
Bit 2-7: unused"
::= { wtWebGraphAnalogIn57642AlarmEntry 32 }
wtWebGraphAnalogIn57642AlarmTimerCron OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This entry contains 5 space or tab seperated text fields for time trigger definition.
Each field must match with the actual time to trigger a message, weekday and day of month
are interpreted separatley.
1: Minutes Range 0-59
2. Hours Range 0-23, 0 is midnight
3: Day of month Range 1-31
4: Month Range 1-12
5: Weekday Range 0-6, 0 is sunday
Syntax for every field:
- an asterix (*) enables every possible setting of a field
- single numbers seperated by commas
- a partition within the allowed range (1-5)
- step size within an partition of the allowed range (0-59/2: every second minute)."
::= { wtWebGraphAnalogIn57642AlarmEntry 33 }
-- wtWebGraphAnalogIn57642GraphicsBase Group
----------------------------
wtWebGraphAnalogIn57642GraphicsBaseEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the viewing options of the graphic:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Auto scroll enable
Bit 1 : Show table
Bit 2 : Show graph
Bit 3 : Show control buttons
Bit 4 : Show config menu
Bit 5-7: unused"
::= { wtWebGraphAnalogIn57642GraphicsBase 1 }
wtWebGraphAnalogIn57642GraphicsBaseWidth OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the width of the graphic in pixels."
::= { wtWebGraphAnalogIn57642GraphicsBase 2 }
wtWebGraphAnalogIn57642GraphicsBaseHeight OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the height of the graphic in pixels."
::= { wtWebGraphAnalogIn57642GraphicsBase 3 }
wtWebGraphAnalogIn57642GraphicsBaseFrameColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Frame color definition in RGB."
::= { wtWebGraphAnalogIn57642GraphicsBase 4 }
wtWebGraphAnalogIn57642GraphicsBaseBackgroundColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Background color definition in RGB."
::= { wtWebGraphAnalogIn57642GraphicsBase 5 }
wtWebGraphAnalogIn57642GraphicsBasePollingrate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the pollingrate in seconds,
which defines the refreshing intervall of the graphic."
::= { wtWebGraphAnalogIn57642GraphicsBase 6 }
-- wtWebGraphAnalogIn57642GraphicsSelect Group
----------------------------
wtWebGraphAnalogIn57642GraphicsSelectDisplaySensorSel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded sensor selection:
only selected sensors will be shown in the graphical presentation:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2: Sensor 3
Bit 3: Sensor 4
Bit 4: Sensor 5
Bit 5: Sensor 6
Bit 6: Sensor 7
Bit 7: Sensor 8"
::= { wtWebGraphAnalogIn57642GraphicsSelect 1 }
wtWebGraphAnalogIn57642GraphicsSelectDisplayShowExtrem OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded sensor selection:
only selected sensors will be shown with minima and maxima:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0: Sensor 1
Bit 1: Sensor 2
Bit 2: Sensor 3
Bit 3: Sensor 4
Bit 4: Sensor 5
Bit 5: Sensor 6
Bit 6: Sensor 7
Bit 7: Sensor 8"
::= { wtWebGraphAnalogIn57642GraphicsSelect 2 }
-- Graph Sensor Color Table
wtWebGraphAnalogIn57642SensorColor2Table OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642SensorColor2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of sensor colors for the praphical presentation."
::= { wtWebGraphAnalogIn57642GraphicsSelect 3 }
wtWebGraphAnalogIn57642SensorColor2Entry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57642SensorColor2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Numbers of the sensors."
INDEX { wtWebGraphAnalogIn57642SensorNo }
::= { wtWebGraphAnalogIn57642SensorColor2Table 1 }
WtWebGraphAnalogIn57642SensorColor2Entry ::= SEQUENCE {
wtWebGraphAnalogIn57642GraphicsSensorColor OCTET STRING,
wtWebGraphAnalogIn57642GraphicsSelectScale OCTET STRING
}
wtWebGraphAnalogIn57642GraphicsSensorColor OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Color of the sensors at the praphical presention."
::= { wtWebGraphAnalogIn57642SensorColor2Entry 1 }
wtWebGraphAnalogIn57642GraphicsSelectScale OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Assignes one of 4 scales to a sensor:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Use Scale 1
Bit 1 : Use Scale 2
Bit 2 : Use Scale 3
Bit 3 : Use Scale 4
Bit 4-7: unused"
::= { wtWebGraphAnalogIn57642SensorColor2Entry 2 }
-- wtWebGraphAnalogIn57642GraphicsScale Group
----------------------------
wtWebGraphAnalogIn57642GraphicsScaleAutoScaleEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select the Auto Scale Mode:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Scale 1 Auto scale enable
Bit 1 : Scale 2 Auto scale enable
Bit 2 : Scale 3 Auto scale enable
Bit 3 : Scale 4 Auto scale enable
Bit 4-7: unused"
::= { wtWebGraphAnalogIn57642GraphicsScale 1 }
wtWebGraphAnalogIn57642GraphicsScaleAutoFitEnable OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Select the Auto Fit Mode::
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : Scale 1 Auto fit enable
Bit 1 : Scale 2 Auto fit enable
Bit 2 : Scale 3 Auto fit enable
Bit 3 : Scale 4 Auto fit enable
Bit 4-7: unused"
::= { wtWebGraphAnalogIn57642GraphicsScale 2 }
wtWebGraphAnalogIn57642GraphicsScale1Min OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 1: Minimum."
::= { wtWebGraphAnalogIn57642GraphicsScale 3 }
wtWebGraphAnalogIn57642GraphicsScale2Min OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 2: Minimum."
::= { wtWebGraphAnalogIn57642GraphicsScale 4 }
wtWebGraphAnalogIn57642GraphicsScale3Min OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 3: Minimum."
::= { wtWebGraphAnalogIn57642GraphicsScale 5 }
wtWebGraphAnalogIn57642GraphicsScale4Min OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 4: Minimum."
::= { wtWebGraphAnalogIn57642GraphicsScale 6 }
wtWebGraphAnalogIn57642GraphicsScale1Max OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 1: Maximum."
::= { wtWebGraphAnalogIn57642GraphicsScale 7 }
wtWebGraphAnalogIn57642GraphicsScale2Max OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 2: Maximum."
::= { wtWebGraphAnalogIn57642GraphicsScale 8 }
wtWebGraphAnalogIn57642GraphicsScale3Max OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 3: Maximum."
::= { wtWebGraphAnalogIn57642GraphicsScale 9 }
wtWebGraphAnalogIn57642GraphicsScale4Max OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 4: Maximum."
::= { wtWebGraphAnalogIn57642GraphicsScale 10 }
wtWebGraphAnalogIn57642GraphicsScale1Unit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 1: Unit."
::= { wtWebGraphAnalogIn57642GraphicsScale 11 }
wtWebGraphAnalogIn57642GraphicsScale2Unit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 2: Unit."
::= { wtWebGraphAnalogIn57642GraphicsScale 12 }
wtWebGraphAnalogIn57642GraphicsScale3Unit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 3: Unit."
::= { wtWebGraphAnalogIn57642GraphicsScale 13 }
wtWebGraphAnalogIn57642GraphicsScale4Unit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Scale 4: Unit."
::= { wtWebGraphAnalogIn57642GraphicsScale 14 }
-- wtWebGraphAnalogIn57642Ports Group
----------------------------
-- Table
wtWebGraphAnalogIn57642PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of settings depending on the sensor number."
::= { wtWebGraphAnalogIn57642Ports 1 }
wtWebGraphAnalogIn57642PortEntry OBJECT-TYPE
SYNTAX WtWebGraphAnalogIn57642PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Sensor parameters for the individual sensors."
INDEX { wtWebGraphAnalogIn57642SensorNo }
::= { wtWebGraphAnalogIn57642PortTable 1 }
WtWebGraphAnalogIn57642PortEntry ::= SEQUENCE {
wtWebGraphAnalogIn57642PortName OCTET STRING,
wtWebGraphAnalogIn57642PortText OCTET STRING,
wtWebGraphAnalogIn57642PortOffset1 OCTET STRING,
wtWebGraphAnalogIn57642SetPoint1 OCTET STRING,
wtWebGraphAnalogIn57642PortOffset2 OCTET STRING,
wtWebGraphAnalogIn57642SetPoint2 OCTET STRING,
wtWebGraphAnalogIn57642PortComment OCTET STRING,
wtWebGraphAnalogIn57642PortSensorSelect OCTET STRING,
wtWebGraphAnalogIn57642PortUnit OCTET STRING,
wtWebGraphAnalogIn57642PortScale0 OCTET STRING,
wtWebGraphAnalogIn57642PortScale100 OCTET STRING
}
wtWebGraphAnalogIn57642PortName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Name of the sensor."
::= { wtWebGraphAnalogIn57642PortEntry 1 }
wtWebGraphAnalogIn57642PortText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of the sensor."
::= { wtWebGraphAnalogIn57642PortEntry 2 }
wtWebGraphAnalogIn57642PortOffset1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 2 decimal places at set point 1."
::= { wtWebGraphAnalogIn57642PortEntry 3 }
wtWebGraphAnalogIn57642SetPoint1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: set point 1 in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57642PortEntry 4 }
wtWebGraphAnalogIn57642PortOffset2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: Offset in degrees with maximum 2 decimal places at set point 2."
::= { wtWebGraphAnalogIn57642PortEntry 5 }
wtWebGraphAnalogIn57642SetPoint2 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: set point 2 in degrees with maximum 2 decimal places."
::= { wtWebGraphAnalogIn57642PortEntry 6 }
wtWebGraphAnalogIn57642PortComment OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Offset calibration: informations of date, name of operator, reference devices."
::= { wtWebGraphAnalogIn57642PortEntry 7 }
wtWebGraphAnalogIn57642PortSensorSelect OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Binary coded options for sensor 1:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : 0-20mA (default)
Bit 1 : 4-20mA
Bit 2 : Disconnect
Bit 3-7: unused
Binary coded options for sensor 2:
Octet 1: unused
Octet 2: unused
Octet 3: unused
Octet 4:
Bit 0 : 0-20mA (default)
Bit 1 : 4-20mA
Bit 2 : Disconnect
Bit 3-7: unused"
::= { wtWebGraphAnalogIn57642PortEntry 8 }
wtWebGraphAnalogIn57642PortUnit OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User scale: displayed unit."
::= { wtWebGraphAnalogIn57642PortEntry 9 }
wtWebGraphAnalogIn57642PortScale0 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User scale: displayed value in 1/1000 at 0% full scale range.
Range: -999999.999 to 999999.999"
::= { wtWebGraphAnalogIn57642PortEntry 10 }
wtWebGraphAnalogIn57642PortScale100 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User scale: displayed value in 1/1000 at 100% full scale range.
Range: -999999.999 to 999999.999"
::= { wtWebGraphAnalogIn57642PortEntry 11 }
-- wtWebGraphAnalogIn57642Manufact Group
----------------------------
wtWebGraphAnalogIn57642MfName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer company name"
::= { wtWebGraphAnalogIn57642Manufact 1 }
wtWebGraphAnalogIn57642MfAddr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer address."
::= { wtWebGraphAnalogIn57642Manufact 2 }
wtWebGraphAnalogIn57642MfHotline OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer hotline."
::= { wtWebGraphAnalogIn57642Manufact 3 }
wtWebGraphAnalogIn57642MfInternet OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer Internet address."
::= { wtWebGraphAnalogIn57642Manufact 4 }
wtWebGraphAnalogIn57642MfDeviceTyp OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer device name (model number)."
::= { wtWebGraphAnalogIn57642Manufact 5 }
wtWebGraphAnalogIn57642MfOrderNo OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Manufacturer part number."
::= { wtWebGraphAnalogIn57642Manufact 6 }
-- wtWebGraphAnalogIn57642Diag Group
----------------------------
wtWebGraphAnalogIn57642DiagErrorCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of entries in the error memory."
::= { wtWebGraphAnalogIn57642Diag 1 }
wtWebGraphAnalogIn57642DiagBinaryError OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Error causes coded bit-by-bit."
::= { wtWebGraphAnalogIn57642Diag 2 }
wtWebGraphAnalogIn57642DiagErrorIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of this variable is used as an index to read
an error massege from wtWebGraphAnalogIn57642DiagErrorMessage.
Errors are numbered from 1 to wtWebGraphAnalogIn57642DiagErrorCount.
Writing a valid value into this variable, making the appropriate
message readable from wtWebGraphAnalogIn57642DiagErrorMessage."
::= { wtWebGraphAnalogIn57642Diag 3 }
wtWebGraphAnalogIn57642DiagErrorMessage OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Using wtWebGraphAnalogIn57642DiagErrorIndex as an index, the appropriate message is available."
::= { wtWebGraphAnalogIn57642Diag 4 }
wtWebGraphAnalogIn57642DiagErrorClear OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Writing 1 into this variable clears all diagnosis messages."
::= { wtWebGraphAnalogIn57642Diag 5 }
-- TRAP DEFINITIONS
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
wtWebGraphAnalogIn57642Alert1 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 1"
--#SUMMARY "Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 31
wtWebGraphAnalogIn57642Alert2 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 2"
--#SUMMARY "Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 32
wtWebGraphAnalogIn57642Alert3 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 3"
--#SUMMARY "Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 33
wtWebGraphAnalogIn57642Alert4 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 4"
--#SUMMARY "Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 34
wtWebGraphAnalogIn57642Alert5 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 5"
--#SUMMARY "Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 35
wtWebGraphAnalogIn57642Alert6 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 6"
--#SUMMARY "Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 36
wtWebGraphAnalogIn57642Alert7 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 7"
--#SUMMARY "Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 37
wtWebGraphAnalogIn57642Alert8 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Alarm 8"
--#SUMMARY "Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 38
wtWebGraphAnalogIn57642Alert9 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 1 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 1"
--#SUMMARY "Release Alarm 1: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 91
wtWebGraphAnalogIn57642Alert10 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 2 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 2"
--#SUMMARY "Release Alarm 2: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 92
wtWebGraphAnalogIn57642Alert11 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 3 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 3"
--#SUMMARY "Release Alarm 3: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 93
wtWebGraphAnalogIn57642Alert12 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 4 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 4"
--#SUMMARY "Release Alarm 4: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 94
wtWebGraphAnalogIn57642Alert13 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 5 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 5"
--#SUMMARY "Release Alarm 5: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 95
wtWebGraphAnalogIn57642Alert14 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 6 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 6"
--#SUMMARY "Release Alarm 6: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 96
wtWebGraphAnalogIn57642Alert15 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 7 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 7"
--#SUMMARY "Release Alarm 7: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 97
wtWebGraphAnalogIn57642Alert16 TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText }
DESCRIPTION
"This SNMP trap is generated when Alarm 8 was cleared,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Release Alarm 8"
--#SUMMARY "Release Alarm 8: %s"
--#ARGUMENTS {0}
--#SEVERITY INFORMATIONAL
--#TIMEINDEX 99
--#STATE OPERATIONAL
::= 98
wtWebGraphAnalogIn57642AlertDiag TRAP-TYPE
ENTERPRISE wtWebGraphAnalogIn57642
VARIABLES {
wtWebGraphAnalogIn57642DiagErrorIndex,
wtWebGraphAnalogIn57642DiagErrorMessage
}
DESCRIPTION
"This SNMP trap is generated when a diagnosis/error message was triggered,
SNMP trap enable is set and
SNMP is enabled."
-- NMS trap annotation
--#TYPE "Thermo-Hygrometer Diagnose Error"
--#SUMMARY "Diagnose error index: %d, Message: %s."
--#ARGUMENTS {0,1}
--#SEVERITY MAJOR
--#TIMEINDEX 99
--#STATE DEGRADED
::= 110
END