WebGraph-AnalogIn-57642-US-MIB DEFINITIONS ::= BEGIN -- adama@observium.org fixed typo 2018-10-24 ---------------------------------------------------------------- -- Revison: 1.29 ---------------------------------------------------------------- -- 22.06.2010 Webio -- Syntax correction ---------------------------------------------------------------- -- Revison: 1.28 ---------------------------------------------------------------- -- 02.12.2008 Webio -- New Graphics java script base parameter ---------------------------------------------------------------- -- Revison: 1.27 ---------------------------------------------------------------- -- 09.11.2006 Webio -- DHCP enable ---------------------------------------------------------------- -- Revison: 1.26 ---------------------------------------------------------------- -- 28.06.2006 New: Community String Trap -- ---------------------------------------------------------------- -- Revison: 1.25 ---------------------------------------------------------------- -- 26.07.2005 #57642, WebGraph AnalogIn 2x 0/4..20mA -- ---------------------------------------------------------------- -- Revison: 1.24 ---------------------------------------------------------------- -- 26.07.2005 #57642, WebGraph AnalogIn -- CRON timer function ---------------------------------------------------------------- -- Revison: 1.23 ---------------------------------------------------------------- -- 14.07.2005 #57642, WebGraph AnalogIn -- FTP functions ---------------------------------------------------------------- -- Revison: 1.22 ---------------------------------------------------------------- -- 17.05.2005 #57642, WebGraph AnalogIn -- Trap NMS annotations ---------------------------------------------------------------- -- Revison: 1.21 ---------------------------------------------------------------- -- 19.04.2005 #57605, WebGraph Themometer -- Mail Authentication ---------------------------------------------------------------- -- Revison: 1.20 ---------------------------------------------------------------- -- 05.11.2004 #57606, WebGraph Thermo-Hygrometer -- New: Syslog -- ---------------------------------------------------------------- -- Revison: 1.19 ---------------------------------------------------------------- -- 08.09.2004 #57606 WebGraph Thermo-Hygrometer -- New: -- wtWebGraphThermHygroAlarmRHMin -- wtWebGraphThermHygroAlarmRHMax -- wtWebGraphThermHygroAlarmRHHysteresis -- wtWebGraphThermHygroPortSensorSelect -- wtWebGraphThermHygroAlarmDeltaTemp -- wtWebGraphThermHygroAlarmAHMin -- wtWebGraphThermHygroAlarmAHMax ---------------------------------------------------------------- -- Revison: 1.18 ---------------------------------------------------------------- -- 21.07.2004 #57601/3/4, Webio Anx -- New: -- Diagnosis ---------------------------------------------------------------- -- Revison: 1.17 ---------------------------------------------------------------- -- 28.06.2004 #57630/1/2, Webio Digital -- Neu: Puls Mode ---------------------------------------------------------------- -- Revison: 1.16 ---------------------------------------------------------------- -- 16.04.2004 New: #57632, Webio Digital EA24x24 -- -- #57630/1, Webio Digital EA12x12 -- New: -- wtWebioEA12x12InputCounterClear ---------------------------------------------------------------- -- Revison: 1.15 ---------------------------------------------------------------- -- 27.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Length changed to 32 Bit: -- wtWebioEA12x12InputValue -- wtWebioEA12x12OutputValue -- wtWebioEA12x12LoadControlView -- wtWebioEA12x12LCShutDownView -- wtWebioEA12x12SetOutput -- wtWebioEA12x12AlarmInputTrigger -- wtWebioEA12x12AlarmOutputTrigger -- wtWebioEA12x12PortOutputSafetyState ---------------------------------------------------------------- -- Revison: 1.14 ---------------------------------------------------------------- -- 16.02.2004 #57630/1, Webio Digital EA12x12 -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger -- -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Alarm Hysteresis -- Alarm Clear Traps and Mails ---------------------------------------------------------------- -- Revison: 1.13 ---------------------------------------------------------------- -- 05.02.2004 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New: -- Text: Location, Contact -- SNMP: ColdStart, WarmStart, ComunityString Read/RW -- Alarm: ColdStart / WarmStart trigger ---------------------------------------------------------------- -- Revison: 1.12 ---------------------------------------------------------------- -- 05.11.2003 #57601, 1xWebThermometer -- #57603, 2xWebThermometer -- #57604, 8xWebThermometer -- New features: -- Mail : Option CSV attachment -- Port : Offset calibration -- Alarm : TCP Client mode ---------------------------------------------------------------- -- Revison: 1.11 ---------------------------------------------------------------- -- 28.10.2003 #57630/1, Webio Digital EA12x12 -- New features: -- Alarm : TCP Client mode -- Inputs: Puls filter ---------------------------------------------------------------- -- Revison: 1.10 ---------------------------------------------------------------- -- 22.07.2003 #57630, Webio Digital EA12x12 -- New navigation tree, new binary modes -- ---------------------------------------------------------------- -- Revison: 1.09 ---------------------------------------------------------------- -- 24.03.2003 Trap Enterprise (Type 1, 2) corrected ---------------------------------------------------------------- -- Revison: 1.08 ---------------------------------------------------------------- -- 04.03.2003 reconciled the language versions DE/US ---------------------------------------------------------------- -- Revison: 1.07 ---------------------------------------------------------------- -- 25.02.2003 Correction: wtWebioEA12x12LoadControl ---------------------------------------------------------------- -- Revison: 1.06 ---------------------------------------------------------------- -- 24.02.2003 New: -- #57630, Webio EA12x12, LoadControl Group -- Correction: Trap variable names ---------------------------------------------------------------- -- Revison: 1.05 ---------------------------------------------------------------- -- 21.01.2003 New: -- #57630, Webio EA12x12 ---------------------------------------------------------------- -- Revison: 1.04 ---------------------------------------------------------------- -- 02.01.2003 New: -- #57601, 1xWebThermometer -- #57603, 2xWebThermometer, 8 alarms ---------------------------------------------------------------- -- Revison: 1.03 ---------------------------------------------------------------- -- 21.11.2002 New: -- #57604, 2xWebThermometer, BOOTP, StartupSite -- #57603, 8xWebThermometer, BOOTP, StartupSite ---------------------------------------------------------------- -- Revison: 1.02 ---------------------------------------------------------------- -- 26.07.2002 New: -- #57604, 2xWebThermometer -- #57603, 8xWebThermometer -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- privat OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { privat 1 } -- Wiesemann & Theis Com-Server MIB wut OBJECT IDENTIFIER ::= { enterprises 5040 } wtComServer OBJECT IDENTIFIER ::= { wut 1 } wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } -- wtWebGraph Tree wtWebGraphAnalogIn57642 OBJECT IDENTIFIER ::= { wtWebio 11 } -- wtWebGraphAnalogIn57642 Tree wtWebGraphAnalogIn57642Inventory OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642 1 } wtWebGraphAnalogIn57642SessCntrl OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642 2 } wtWebGraphAnalogIn57642Config OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642 3 } wtWebGraphAnalogIn57642Diag OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642 4 } -- wtWebGraphAnalogIn57642Config Tree wtWebGraphAnalogIn57642Device OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Config 1 } wtWebGraphAnalogIn57642Ports OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Config 2 } wtWebGraphAnalogIn57642Manufact OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Config 3 } -- wtWebGraphAnalogIn57642Device Tree wtWebGraphAnalogIn57642Text OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 1 } wtWebGraphAnalogIn57642TimeDate OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 2 } wtWebGraphAnalogIn57642Basic OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 3 } wtWebGraphAnalogIn57642Datalogger OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 4 } wtWebGraphAnalogIn57642Alarm OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 5 } wtWebGraphAnalogIn57642Graphics OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Device 6 } -- wtWebGraphAnalogIn57642TimeDate Tree wtWebGraphAnalogIn57642TimeZone OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642TimeDate 1 } wtWebGraphAnalogIn57642TimeServer OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642TimeDate 2 } wtWebGraphAnalogIn57642DeviceClock OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642TimeDate 3 } -- wtWebGraphAnalogIn57642Basic Tree wtWebGraphAnalogIn57642Network OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 1 } wtWebGraphAnalogIn57642HTTP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 2 } wtWebGraphAnalogIn57642Mail OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 3 } wtWebGraphAnalogIn57642SNMP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 4 } wtWebGraphAnalogIn57642UDP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 5 } wtWebGraphAnalogIn57642Syslog OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 6 } wtWebGraphAnalogIn57642FTP OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Basic 7 } -- wtWebGraphAnalogIn57642Graphics Tree wtWebGraphAnalogIn57642GraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Graphics 1 } wtWebGraphAnalogIn57642GraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Graphics 2 } wtWebGraphAnalogIn57642GraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphAnalogIn57642Graphics 3 } -- wtWebGraphAnalogIn57642Inventory Group ------------------------ wtWebGraphAnalogIn57642Sensors OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Number of sensors" ::= { wtWebGraphAnalogIn57642Inventory 1 } -- Interface Table wtWebGraphAnalogIn57642SensorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642SensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensors." ::= { wtWebGraphAnalogIn57642Inventory 2 } wtWebGraphAnalogIn57642SensorEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57642SensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor numbers." INDEX { wtWebGraphAnalogIn57642SensorNo } ::= { wtWebGraphAnalogIn57642SensorTable 1 } WtWebGraphAnalogIn57642SensorEntry ::= SEQUENCE { wtWebGraphAnalogIn57642SensorNo INTEGER } wtWebGraphAnalogIn57642SensorNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Sensor number." ::= { wtWebGraphAnalogIn57642SensorEntry 1 } -- wtWebGraphAnalogIn57642Values Table wtWebGraphAnalogIn57642ValuesTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642ValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of measurement values corresponding to the channel numbers." ::= { wtWebGraphAnalogIn57642Inventory 3 } wtWebGraphAnalogIn57642ValuesEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57642ValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Measurement values of the sensors." INDEX { wtWebGraphAnalogIn57642SensorNo } ::= { wtWebGraphAnalogIn57642ValuesTable 1 } WtWebGraphAnalogIn57642ValuesEntry ::= SEQUENCE{ wtWebGraphAnalogIn57642Values OCTET STRING } wtWebGraphAnalogIn57642Values OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Measurement value of the sensor, ASCII, 7 characters in length." ::= { wtWebGraphAnalogIn57642ValuesEntry 1 } -- wtWebGraphAnalogIn57642BinaryValues Table wtWebGraphAnalogIn57642BinaryValuesTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642BinaryValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of binary measurement values corresponding to the channel numbers." ::= { wtWebGraphAnalogIn57642Inventory 4 } wtWebGraphAnalogIn57642BinaryValuesEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57642BinaryValuesEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binary measurement values of the sensors." INDEX { wtWebGraphAnalogIn57642SensorNo } ::= { wtWebGraphAnalogIn57642BinaryValuesTable 1 } WtWebGraphAnalogIn57642BinaryValuesEntry ::= SEQUENCE{ wtWebGraphAnalogIn57642BinaryValues INTEGER } wtWebGraphAnalogIn57642BinaryValues OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Binary measurement value of the sensor in 1/10 degrees Celsius or 1/10 per cent, signed number, 0x4FFF6 indicates an invalid measured value." ::= { wtWebGraphAnalogIn57642BinaryValuesEntry 1 } -- wtWebGraphAnalogIn57642SessCntrl Group -------------------------------- wtWebGraphAnalogIn57642SessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Entering this password opens a session which is ended by writing a 1 to wtWebGraphAnalogIn57642SessCntrlLogout. When read this variable provides a string of length zero." ::= { wtWebGraphAnalogIn57642SessCntrl 1 } wtWebGraphAnalogIn57642SessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57642SessCntrl-NoSession(0), wtWebGraphAnalogIn57642SessCntrl-Session(1) } ACCESS read-only STATUS mandatory DESCRIPTION "When the device is in SNMP configuration mode, the value 1 is returned, otherwise 0. If the read value is 0 even though the password was written, the device is already in config mode and the variables can only be read." ::= { wtWebGraphAnalogIn57642SessCntrl 2 } wtWebGraphAnalogIn57642SessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "If the device is in configuration mode and the session was opened by this SNMP Manager, writing a 1 to this variable will end the session and all parameters are stored. Writing a 2 discards all entries again. When read this variable provides the value 0." ::= { wtWebGraphAnalogIn57642SessCntrl 3 } wtWebGraphAnalogIn57642SessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with administrator rights. It can only be changed by the administrator. If no password was assigned, the valid password is public." ::= { wtWebGraphAnalogIn57642SessCntrl 4 } wtWebGraphAnalogIn57642SessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This password protects access to the variables with configurator rights. It can be changed by the administrator and by the configurator. If no password was assigned, the valid password is public. When read this variable provides a null-pointer." ::= { wtWebGraphAnalogIn57642SessCntrl 5 } -- wtWebGraphAnalogIn57642Text Group ------------------------ wtWebGraphAnalogIn57642DeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the Webio, which is user definable." ::= { wtWebGraphAnalogIn57642Text 1 } wtWebGraphAnalogIn57642DeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the Webio, which is user definable." ::= { wtWebGraphAnalogIn57642Text 2 } wtWebGraphAnalogIn57642DeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the location of the Webio, which is user definable." ::= { wtWebGraphAnalogIn57642Text 3 } wtWebGraphAnalogIn57642DeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Contact address of the system operator of the Webio, which is user definable." ::= { wtWebGraphAnalogIn57642Text 4 } -- wtWebGraphAnalogIn57642TimeZone Group ---------------------------- wtWebGraphAnalogIn57642TzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours for the time zone (winter time) with respect to UTC." ::= { wtWebGraphAnalogIn57642TimeZone 1 } wtWebGraphAnalogIn57642TzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes for the time zone (winter time) with respect to UTC." ::= { wtWebGraphAnalogIn57642TimeZone 2 } wtWebGraphAnalogIn57642TzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Timezone" ::= { wtWebGraphAnalogIn57642TimeZone 3 } wtWebGraphAnalogIn57642StTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset hours of the time zone (summer time) with respect to UTC." ::= { wtWebGraphAnalogIn57642TimeZone 4 } wtWebGraphAnalogIn57642StTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset minutes of the time zone (summer time) with respect to UTC." ::= { wtWebGraphAnalogIn57642TimeZone 5 } wtWebGraphAnalogIn57642StTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Summertime" ::= { wtWebGraphAnalogIn57642TimeZone 6 } wtWebGraphAnalogIn57642StTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57642StartMonth-January(1), wtWebGraphAnalogIn57642StartMonth-February(2), wtWebGraphAnalogIn57642StartMonth-March(3), wtWebGraphAnalogIn57642StartMonth-April(4), wtWebGraphAnalogIn57642StartMonth-May(5), wtWebGraphAnalogIn57642StartMonth-June(6), wtWebGraphAnalogIn57642StartMonth-July(7), wtWebGraphAnalogIn57642StartMonth-August(8), wtWebGraphAnalogIn57642StartMonth-September(9), wtWebGraphAnalogIn57642StartMonth-October(10), wtWebGraphAnalogIn57642StartMonth-November(11), wtWebGraphAnalogIn57642StartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from winter time to summer time." ::= { wtWebGraphAnalogIn57642TimeZone 7 } wtWebGraphAnalogIn57642StTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57642StartMode-first(1), wtWebGraphAnalogIn57642StartMode-second(2), wtWebGraphAnalogIn57642StartMode-third(3), wtWebGraphAnalogIn57642StartMode-fourth(4), wtWebGraphAnalogIn57642StartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the day of the week for which the change is made from winter time to summer time." ::= { wtWebGraphAnalogIn57642TimeZone 8 } wtWebGraphAnalogIn57642StTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57642StartWday-Sunday(1), wtWebGraphAnalogIn57642StartWday-Monday(2), wtWebGraphAnalogIn57642StartWday-Tuesday(3), wtWebGraphAnalogIn57642StartWday-Thursday(4), wtWebGraphAnalogIn57642StartWday-Wednesday(5), wtWebGraphAnalogIn57642StartWday-Friday(6), wtWebGraphAnalogIn57642StartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from winter time to summer time" ::= { wtWebGraphAnalogIn57642TimeZone 9 } wtWebGraphAnalogIn57642StTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebGraphAnalogIn57642TimeZone 10 } wtWebGraphAnalogIn57642StTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute in which the time zone is changed from winter to summer time with respect to UTC." ::= { wtWebGraphAnalogIn57642TimeZone 11 } wtWebGraphAnalogIn57642StTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57642StopMonth-January(1), wtWebGraphAnalogIn57642StopMonth-February(2), wtWebGraphAnalogIn57642StopMonth-March(3), wtWebGraphAnalogIn57642StopMonth-April(4), wtWebGraphAnalogIn57642StopMonth-May(5), wtWebGraphAnalogIn57642StopMonth-June(6), wtWebGraphAnalogIn57642StopMonth-July(7), wtWebGraphAnalogIn57642StopMonth-August(8), wtWebGraphAnalogIn57642StopMonth-September(9), wtWebGraphAnalogIn57642StopMonth-October(10), wtWebGraphAnalogIn57642StopMonth-November(11), wtWebGraphAnalogIn57642StopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Month in which the change is made from summer time to winter time." ::= { wtWebGraphAnalogIn57642TimeZone 12 } wtWebGraphAnalogIn57642StTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57642StopMode-first(1), wtWebGraphAnalogIn57642StopMode-second(2), wtWebGraphAnalogIn57642StopMode-third(3), wtWebGraphAnalogIn57642StopMode-fourth(4), wtWebGraphAnalogIn57642StopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Mode of the week day on which the change is made from summer time to winter time." ::= { wtWebGraphAnalogIn57642TimeZone 13 } wtWebGraphAnalogIn57642StTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57642StopWday-Sunday(1), wtWebGraphAnalogIn57642StopWday-Monday(2), wtWebGraphAnalogIn57642StopWday-Tuesday(3), wtWebGraphAnalogIn57642StopWday-Thursday(4), wtWebGraphAnalogIn57642StopWday-Wednesday(5), wtWebGraphAnalogIn57642StopWday-Friday(6), wtWebGraphAnalogIn57642StopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Day of the week on which the change is made from summer time to winter time." ::= { wtWebGraphAnalogIn57642TimeZone 14 } wtWebGraphAnalogIn57642StTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Hour at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebGraphAnalogIn57642TimeZone 15 } wtWebGraphAnalogIn57642StTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute at which the time zone is changed from summer to winter time with respect to UTC." ::= { wtWebGraphAnalogIn57642TimeZone 16 } -- wtWebGraphAnalogIn57642TimeServer Group ---------------------------- wtWebGraphAnalogIn57642TimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 1st time server in ASCII" ::= { wtWebGraphAnalogIn57642TimeServer 1 } wtWebGraphAnalogIn57642TimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address or name of the 2nd time server in ASCII" ::= { wtWebGraphAnalogIn57642TimeServer 2 } wtWebGraphAnalogIn57642TsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Apply Time Server" ::= { wtWebGraphAnalogIn57642TimeServer 3 } wtWebGraphAnalogIn57642TsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Daily synchronisation time with the time server (hour: 0-23)." ::= { wtWebGraphAnalogIn57642TimeServer 4 } -- wtWebGraphAnalogIn57642DeviceClock Group ---------------------------- wtWebGraphAnalogIn57642ClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Clock hours taking into account the time zone settings." ::= { wtWebGraphAnalogIn57642DeviceClock 1 } wtWebGraphAnalogIn57642ClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Clock minutes taking into account the time zone settings." ::= { wtWebGraphAnalogIn57642DeviceClock 2 } wtWebGraphAnalogIn57642ClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Day of the month, taking into account the time zone settings." ::= { wtWebGraphAnalogIn57642DeviceClock 3 } wtWebGraphAnalogIn57642ClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57642ClockMonth-January(1), wtWebGraphAnalogIn57642ClockMonth-February(2), wtWebGraphAnalogIn57642ClockMonth-March(3), wtWebGraphAnalogIn57642ClockMonth-April(4), wtWebGraphAnalogIn57642ClockMonth-May(5), wtWebGraphAnalogIn57642ClockMonth-June(6), wtWebGraphAnalogIn57642ClockMonth-July(7), wtWebGraphAnalogIn57642ClockMonth-August(8), wtWebGraphAnalogIn57642ClockMonth-September(9), wtWebGraphAnalogIn57642ClockMonth-October(10), wtWebGraphAnalogIn57642ClockMonth-November(11), wtWebGraphAnalogIn57642ClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Date: Month, taking into account the time zone settings." ::= { wtWebGraphAnalogIn57642DeviceClock 4 } wtWebGraphAnalogIn57642ClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Date: Year, taking into account the time zone settings." ::= { wtWebGraphAnalogIn57642DeviceClock 5 } -- wtWebGraphAnalogIn57642Network Group ------------------------ wtWebGraphAnalogIn57642IpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the Webio" ::= { wtWebGraphAnalogIn57642Network 1 } wtWebGraphAnalogIn57642SubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnet mask of the Webio" ::= { wtWebGraphAnalogIn57642Network 2 } wtWebGraphAnalogIn57642Gateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway of the Webio" ::= { wtWebGraphAnalogIn57642Network 3 } wtWebGraphAnalogIn57642DnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 1st DNS server in ASCII" ::= { wtWebGraphAnalogIn57642Network 4 } wtWebGraphAnalogIn57642DnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the 2nd DNS server in ASCII" ::= { wtWebGraphAnalogIn57642Network 5 } wtWebGraphAnalogIn57642AddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Additional configuration (1=ON): Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: DHCP disable Bit 0: BOOTP disable " ::= { wtWebGraphAnalogIn57642Network 6 } -- wtWebGraphAnalogIn57642HTTP Group -------------------------------- wtWebGraphAnalogIn57642Startup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded start page: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1: Index.htm Bit 2: Home.htm Bit 3: User.htm Only one page may be selected at a time." ::= { wtWebGraphAnalogIn57642HTTP 1 } wtWebGraphAnalogIn57642GetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If these bits are set, every answer of a short form GET question will be lead by the IP-address and name of the device and/or a HTTP header: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-6: unused Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebGraphAnalogIn57642HTTP 2 } wtWebGraphAnalogIn57642HttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Definition of the standard HTML port (Default: 80)." ::= { wtWebGraphAnalogIn57642HTTP 3 } -- wtWebGraphAnalogIn57642Mail Group -------------------------------- wtWebGraphAnalogIn57642MailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Device name for mail administration." ::= { wtWebGraphAnalogIn57642Mail 1 } wtWebGraphAnalogIn57642MailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply address for the mail server." ::= { wtWebGraphAnalogIn57642Mail 2 } wtWebGraphAnalogIn57642MailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the mail server." ::= { wtWebGraphAnalogIn57642Mail 3 } wtWebioAn1MailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable the sending of mails: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Mail enable" ::= { wtWebGraphAnalogIn57642Mail 4 } wtWebGraphAnalogIn57642MailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Selection of the authentication modi: The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds to the LSB. OCTET 1: unused OCTET 2: unused OCTET 3: unused OCTET 4: Bit 3-7: unused Bit 2 : POP3 before SMTP Bit 1 : ESMTP, authentication Bit 0 : SMTP, no authentication" ::= { wtWebGraphAnalogIn57642Mail 5 } wtWebGraphAnalogIn57642MailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the user to be authenticated." ::= { wtWebGraphAnalogIn57642Mail 6 } wtWebGraphAnalogIn57642MailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Authentication password." ::= { wtWebGraphAnalogIn57642Mail 7 } wtWebGraphAnalogIn57642MailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or Ip-address of the POP3 Servers." ::= { wtWebGraphAnalogIn57642Mail 8 } -- wtWebGraphAnalogIn57642SNMP Group -------------------------------- wtWebGraphAnalogIn57642SnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebGraphAnalogIn57642SNMP 1 } wtWebGraphAnalogIn57642SnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebGraphAnalogIn57642SNMP 2 } wtWebGraphAnalogIn57642SystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the system trap." ::= { wtWebGraphAnalogIn57642SNMP 3 } wtWebGraphAnalogIn57642SystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: unused" ::= { wtWebGraphAnalogIn57642SNMP 4 } wtWebGraphAnalogIn57642SnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0 to enable SNMP. If disabled, the device did not respond to any SNMP requests. Bit 1 decided wether the community string of read operations is compared with the system password or not: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : SNMP enable" ::= { wtWebGraphAnalogIn57642SNMP 5 } wtWebGraphAnalogIn57642SnmpCommunityStringTrap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string send within traps." ::= { wtWebGraphAnalogIn57642SNMP 6 } -- wtWebGraphAnalogIn57642UDP Group -------------------------------- wtWebGraphAnalogIn57642UdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Udp port to which the Udp queries ( short form GET requests) can be sent. This port number must be unique within the device." ::= { wtWebGraphAnalogIn57642UDP 1 } wtWebGraphAnalogIn57642UdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set this bit to enable UDP support: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : UDP enable" ::= { wtWebGraphAnalogIn57642UDP 2 } -- wtWebGraphAnalogIn57642Syslog Group -------------------------------- wtWebGraphAnalogIn57642SyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the Syslog server, which accepts the Syslog messgaes." ::= { wtWebGraphAnalogIn57642Syslog 1 } wtWebGraphAnalogIn57642SyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the Syslog servers, default 514." ::= { wtWebGraphAnalogIn57642Syslog 2 } wtWebGraphAnalogIn57642SyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: unused" ::= { wtWebGraphAnalogIn57642Syslog 3 } wtWebGraphAnalogIn57642SyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set bit 0to enable Syslog: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Syslog enable" ::= { wtWebGraphAnalogIn57642Syslog 4 } -- wtWebGraphAnalogIn57642FTP Group -------------------------------- wtWebGraphAnalogIn57642FTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the FTP server, which accepts the FTP messages." ::= { wtWebGraphAnalogIn57642FTP 1 } wtWebGraphAnalogIn57642FTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnumber of the control port of the FTP server, default 21." ::= { wtWebGraphAnalogIn57642FTP 2 } wtWebGraphAnalogIn57642FTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user name." ::= { wtWebGraphAnalogIn57642FTP 3 } wtWebGraphAnalogIn57642FTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: user password." ::= { wtWebGraphAnalogIn57642FTP 4 } wtWebGraphAnalogIn57642FTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: name of account." ::= { wtWebGraphAnalogIn57642FTP 5 } wtWebGraphAnalogIn57642FTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 switches the FTP Server in Passiv-Mode, the Client controls the data connection on its own: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : PASV enable" ::= { wtWebGraphAnalogIn57642FTP 6 } wtWebGraphAnalogIn57642FTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set Bit 0 to enable FTP: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : FTP enable" ::= { wtWebGraphAnalogIn57642FTP 7 } -- wtWebGraphAnalogIn57642Datalogger Group -------------------------------- wtWebGraphAnalogIn57642LoggerTimebase OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57642Datalogger-1Min(1), wtWebGraphAnalogIn57642Datalogger-5Min(2), wtWebGraphAnalogIn57642Datalogger-15Min(3), wtWebGraphAnalogIn57642Datalogger-60Min(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Time base of the data logger" ::= { wtWebGraphAnalogIn57642Datalogger 1 } wtWebGraphAnalogIn57642LoggerSensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalogIn57642Datalogger 2 } wtWebGraphAnalogIn57642DisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalogIn57642Datalogger 3 } -- Graph Sensor Color Table wtWebGraphAnalogIn57642SensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642SensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebGraphAnalogIn57642Datalogger 4 } wtWebGraphAnalogIn57642SensorColorEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57642SensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Index numbers of the sensors." INDEX { wtWebGraphAnalogIn57642SensorNo } ::= { wtWebGraphAnalogIn57642SensorColorTable 1 } WtWebGraphAnalogIn57642SensorColorEntry ::= SEQUENCE { wtWebGraphAnalogIn57642SensorColor OCTET STRING } wtWebGraphAnalogIn57642SensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebGraphAnalogIn57642SensorColorEntry 1 } wtWebGraphAnalogIn57642AutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "If bit 0 is set, vertical auto scale is enabled: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 1-7: unused Bit 0 : Auto Scale enable" ::= { wtWebGraphAnalogIn57642Datalogger 5 } wtWebGraphAnalogIn57642VerticalUpperLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the maximum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57642Datalogger 6 } wtWebGraphAnalogIn57642VerticalLowerLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This value defines the minimum temperature shown in the graphical presentation, if no auto scaling is selected. Temperature in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57642Datalogger 7 } wtWebGraphAnalogIn57642HorizontalZoom OBJECT-TYPE SYNTAX INTEGER { wtWebGraphAnalogIn57642Zoom-25min(1), wtWebGraphAnalogIn57642Zoom-75min(2), wtWebGraphAnalogIn57642Zoom-5hrs(3), wtWebGraphAnalogIn57642Zoom-30hrs(4), wtWebGraphAnalogIn57642Zoom-5days(5), wtWebGraphAnalogIn57642Zoom-25days(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the default zoom stage, if no auto scaling is selected." ::= { wtWebGraphAnalogIn57642Datalogger 8 } -- wtWebGraphAnalogIn57642Alarm Group ---------------------------- wtWebGraphAnalogIn57642AlarmCount OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Number of independent alarms." ::= { wtWebGraphAnalogIn57642Alarm 1 } -- Alarm Interface Table wtWebGraphAnalogIn57642AlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of alarm indices." ::= { wtWebGraphAnalogIn57642Alarm 2 } wtWebGraphAnalogIn57642AlarmIfEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57642AlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the alarms." INDEX { wtWebGraphAnalogIn57642AlarmNo } ::= { wtWebGraphAnalogIn57642AlarmIfTable 1 } WtWebGraphAnalogIn57642AlarmIfEntry ::= SEQUENCE { wtWebGraphAnalogIn57642AlarmNo INTEGER } wtWebGraphAnalogIn57642AlarmNo OBJECT-TYPE SYNTAX INTEGER (1..8) ACCESS read-only STATUS mandatory DESCRIPTION "Alarm number." ::= { wtWebGraphAnalogIn57642AlarmIfEntry 1 } -- Alarm Table wtWebGraphAnalogIn57642AlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the alarm number." ::= { wtWebGraphAnalogIn57642Alarm 3 } wtWebGraphAnalogIn57642AlarmEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57642AlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm parameters of the individual alarms." INDEX { wtWebGraphAnalogIn57642AlarmNo } ::= { wtWebGraphAnalogIn57642AlarmTable 1 } WtWebGraphAnalogIn57642AlarmEntry ::= SEQUENCE { wtWebGraphAnalogIn57642AlarmTrigger OCTET STRING, wtWebGraphAnalogIn57642AlarmMin OCTET STRING, wtWebGraphAnalogIn57642AlarmMax OCTET STRING, wtWebGraphAnalogIn57642AlarmHysteresis OCTET STRING, wtWebGraphAnalogIn57642AlarmDelay OCTET STRING, wtWebGraphAnalogIn57642AlarmInterval OCTET STRING, wtWebGraphAnalogIn57642AlarmEnable OCTET STRING, wtWebGraphAnalogIn57642AlarmEMailAddr OCTET STRING, wtWebGraphAnalogIn57642AlarmMailSubject OCTET STRING, wtWebGraphAnalogIn57642AlarmMailText OCTET STRING, wtWebGraphAnalogIn57642AlarmManagerIP OCTET STRING, wtWebGraphAnalogIn57642AlarmTrapText OCTET STRING, wtWebGraphAnalogIn57642AlarmMailOptions OCTET STRING, wtWebGraphAnalogIn57642AlarmTcpIpAddr OCTET STRING, wtWebGraphAnalogIn57642AlarmTcpPort INTEGER, wtWebGraphAnalogIn57642AlarmTcpText OCTET STRING, wtWebGraphAnalogIn57642AlarmClearMailSubject OCTET STRING, wtWebGraphAnalogIn57642AlarmClearMailText OCTET STRING, wtWebGraphAnalogIn57642AlarmClearTrapText OCTET STRING, wtWebGraphAnalogIn57642AlarmClearTcpText OCTET STRING, wtWebGraphAnalogIn57642Alarm2Min OCTET STRING, wtWebGraphAnalogIn57642Alarm2Max OCTET STRING, wtWebGraphAnalogIn57642Alarm2Hysteresis OCTET STRING, wtWebGraphAnalogIn57642AlarmSyslogIpAddr OCTET STRING, wtWebGraphAnalogIn57642AlarmSyslogPort INTEGER, wtWebGraphAnalogIn57642AlarmSyslogText OCTET STRING, wtWebGraphAnalogIn57642AlarmSyslogClearText OCTET STRING, wtWebGraphAnalogIn57642AlarmFtpDataPort OCTET STRING, wtWebGraphAnalogIn57642AlarmFtpFileName OCTET STRING, wtWebGraphAnalogIn57642AlarmFtpText OCTET STRING, wtWebGraphAnalogIn57642AlarmFtpClearText OCTET STRING, wtWebGraphAnalogIn57642AlarmFtpOption OCTET STRING, wtWebGraphAnalogIn57642AlarmTimerCron OCTET STRING } wtWebGraphAnalogIn57642AlarmTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded trigger conditions: Octet 1: unused Octet 2: unused Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2-7: unused" ::= { wtWebGraphAnalogIn57642AlarmEntry 1 } wtWebGraphAnalogIn57642AlarmMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum temperature in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57642AlarmEntry 2 } wtWebGraphAnalogIn57642AlarmMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum temperature in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57642AlarmEntry 3 } wtWebGraphAnalogIn57642AlarmHysteresis OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Temperature changes of this size clears the alarm state (MAX-hyst, MIN+hyst.) , in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57642AlarmEntry 4 } wtWebGraphAnalogIn57642AlarmDelay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm will be delayed by setting this time while stable alarm condition occur (time in minutes)." ::= { wtWebGraphAnalogIn57642AlarmEntry 5 } wtWebGraphAnalogIn57642AlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Send interval for alarm messages." ::= { wtWebGraphAnalogIn57642AlarmEntry 6 } wtWebGraphAnalogIn57642AlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded alarm enable: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable" ::= { wtWebGraphAnalogIn57642AlarmEntry 7 } wtWebGraphAnalogIn57642AlarmEMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail address for sending the alarm mail to." ::= { wtWebGraphAnalogIn57642AlarmEntry 8 } wtWebGraphAnalogIn57642AlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm mail." ::= { wtWebGraphAnalogIn57642AlarmEntry 9 } wtWebGraphAnalogIn57642AlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm mail text: provides the current temperature; n = 1..8. provides the current time." ::= { wtWebGraphAnalogIn57642AlarmEntry 10 } wtWebGraphAnalogIn57642AlarmManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the SNMP Manager which accepts the trap." ::= { wtWebGraphAnalogIn57642AlarmEntry 11 } wtWebGraphAnalogIn57642AlarmTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebGraphAnalogIn57642AlarmEntry 12 } wtWebGraphAnalogIn57642AlarmMailOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: unused" ::= { wtWebGraphAnalogIn57642AlarmEntry 13 } wtWebGraphAnalogIn57642AlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name or IP address of the TCP server which accepts the trap." ::= { wtWebGraphAnalogIn57642AlarmEntry 14 } wtWebGraphAnalogIn57642AlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the TCP server which accepts the trap." ::= { wtWebGraphAnalogIn57642AlarmEntry 15 } wtWebGraphAnalogIn57642AlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebGraphAnalogIn57642AlarmEntry 16 } wtWebGraphAnalogIn57642AlarmClearMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Subject line for alarm clear mail." ::= { wtWebGraphAnalogIn57642AlarmEntry 17 } wtWebGraphAnalogIn57642AlarmClearMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear mail text: provides the current temperature; n = 1..8. provides the current time." ::= { wtWebGraphAnalogIn57642AlarmEntry 18 } wtWebGraphAnalogIn57642AlarmClearTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the trap body." ::= { wtWebGraphAnalogIn57642AlarmEntry 19 } wtWebGraphAnalogIn57642AlarmClearTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This text is sent in the TCP trap body." ::= { wtWebGraphAnalogIn57642AlarmEntry 20 } wtWebGraphAnalogIn57642Alarm2Min OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum rel. Humidity in percent with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57642AlarmEntry 21 } wtWebGraphAnalogIn57642Alarm2Max OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum rel.Humidity in percent with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57642AlarmEntry 22 } wtWebGraphAnalogIn57642Alarm2Hysteresis OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Hysterese rel. Humidity in percent with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57642AlarmEntry 23 } wtWebGraphAnalogIn57642AlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP address of the syslog server to which the Webio device should send syslog messages." ::= { wtWebGraphAnalogIn57642AlarmEntry 24 } wtWebGraphAnalogIn57642AlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Port number of the syslog server to which the Webio device should send syslog messages." ::= { wtWebGraphAnalogIn57642AlarmEntry 25 } wtWebGraphAnalogIn57642AlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body." ::= { wtWebGraphAnalogIn57642AlarmEntry 26 } wtWebGraphAnalogIn57642AlarmSyslogClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Every message starts with the priority key, a time stamp and the host ip address, according RFC3164. This text appears in the following syslog message body of a alarm clear message." ::= { wtWebGraphAnalogIn57642AlarmEntry 27 } wtWebGraphAnalogIn57642AlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Local data port: 1..65535 or AUTO: the next free port will be assigned." ::= { wtWebGraphAnalogIn57642AlarmEntry 28 } wtWebGraphAnalogIn57642AlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the file including path informations." ::= { wtWebGraphAnalogIn57642AlarmEntry 29 } wtWebGraphAnalogIn57642AlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Message text to store on the FTP server." ::= { wtWebGraphAnalogIn57642AlarmEntry 30 } wtWebGraphAnalogIn57642AlarmFtpClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Alarm clear message to store on the FTP server." ::= { wtWebGraphAnalogIn57642AlarmEntry 31 } wtWebGraphAnalogIn57642AlarmFtpOption OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options, select only one option at the same time: STORE = replace file APPEND = append message at the end of the file Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: unused" ::= { wtWebGraphAnalogIn57642AlarmEntry 32 } wtWebGraphAnalogIn57642AlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "This entry contains 5 space or tab seperated text fields for time trigger definition. Each field must match with the actual time to trigger a message, weekday and day of month are interpreted separatley. 1: Minutes Range 0-59 2. Hours Range 0-23, 0 is midnight 3: Day of month Range 1-31 4: Month Range 1-12 5: Weekday Range 0-6, 0 is sunday Syntax for every field: - an asterix (*) enables every possible setting of a field - single numbers seperated by commas - a partition within the allowed range (1-5) - step size within an partition of the allowed range (0-59/2: every second minute)." ::= { wtWebGraphAnalogIn57642AlarmEntry 33 } -- wtWebGraphAnalogIn57642GraphicsBase Group ---------------------------- wtWebGraphAnalogIn57642GraphicsBaseEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Defines the viewing options of the graphic: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: unused" ::= { wtWebGraphAnalogIn57642GraphicsBase 1 } wtWebGraphAnalogIn57642GraphicsBaseWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the width of the graphic in pixels." ::= { wtWebGraphAnalogIn57642GraphicsBase 2 } wtWebGraphAnalogIn57642GraphicsBaseHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the height of the graphic in pixels." ::= { wtWebGraphAnalogIn57642GraphicsBase 3 } wtWebGraphAnalogIn57642GraphicsBaseFrameColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Frame color definition in RGB." ::= { wtWebGraphAnalogIn57642GraphicsBase 4 } wtWebGraphAnalogIn57642GraphicsBaseBackgroundColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Background color definition in RGB." ::= { wtWebGraphAnalogIn57642GraphicsBase 5 } wtWebGraphAnalogIn57642GraphicsBasePollingrate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Defines the pollingrate in seconds, which defines the refreshing intervall of the graphic." ::= { wtWebGraphAnalogIn57642GraphicsBase 6 } -- wtWebGraphAnalogIn57642GraphicsSelect Group ---------------------------- wtWebGraphAnalogIn57642GraphicsSelectDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown in the graphical presentation: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebGraphAnalogIn57642GraphicsSelect 1 } wtWebGraphAnalogIn57642GraphicsSelectDisplayShowExtrem OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded sensor selection: only selected sensors will be shown with minima and maxima: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebGraphAnalogIn57642GraphicsSelect 2 } -- Graph Sensor Color Table wtWebGraphAnalogIn57642SensorColor2Table OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642SensorColor2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of sensor colors for the praphical presentation." ::= { wtWebGraphAnalogIn57642GraphicsSelect 3 } wtWebGraphAnalogIn57642SensorColor2Entry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57642SensorColor2Entry ACCESS not-accessible STATUS mandatory DESCRIPTION "Numbers of the sensors." INDEX { wtWebGraphAnalogIn57642SensorNo } ::= { wtWebGraphAnalogIn57642SensorColor2Table 1 } WtWebGraphAnalogIn57642SensorColor2Entry ::= SEQUENCE { wtWebGraphAnalogIn57642GraphicsSensorColor OCTET STRING, wtWebGraphAnalogIn57642GraphicsSelectScale OCTET STRING } wtWebGraphAnalogIn57642GraphicsSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Color of the sensors at the praphical presention." ::= { wtWebGraphAnalogIn57642SensorColor2Entry 1 } wtWebGraphAnalogIn57642GraphicsSelectScale OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Assignes one of 4 scales to a sensor: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3 : Use Scale 4 Bit 4-7: unused" ::= { wtWebGraphAnalogIn57642SensorColor2Entry 2 } -- wtWebGraphAnalogIn57642GraphicsScale Group ---------------------------- wtWebGraphAnalogIn57642GraphicsScaleAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Scale Mode: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2 : Scale 3 Auto scale enable Bit 3 : Scale 4 Auto scale enable Bit 4-7: unused" ::= { wtWebGraphAnalogIn57642GraphicsScale 1 } wtWebGraphAnalogIn57642GraphicsScaleAutoFitEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Select the Auto Fit Mode:: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2 : Scale 3 Auto fit enable Bit 3 : Scale 4 Auto fit enable Bit 4-7: unused" ::= { wtWebGraphAnalogIn57642GraphicsScale 2 } wtWebGraphAnalogIn57642GraphicsScale1Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Minimum." ::= { wtWebGraphAnalogIn57642GraphicsScale 3 } wtWebGraphAnalogIn57642GraphicsScale2Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Minimum." ::= { wtWebGraphAnalogIn57642GraphicsScale 4 } wtWebGraphAnalogIn57642GraphicsScale3Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Minimum." ::= { wtWebGraphAnalogIn57642GraphicsScale 5 } wtWebGraphAnalogIn57642GraphicsScale4Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Minimum." ::= { wtWebGraphAnalogIn57642GraphicsScale 6 } wtWebGraphAnalogIn57642GraphicsScale1Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Maximum." ::= { wtWebGraphAnalogIn57642GraphicsScale 7 } wtWebGraphAnalogIn57642GraphicsScale2Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Maximum." ::= { wtWebGraphAnalogIn57642GraphicsScale 8 } wtWebGraphAnalogIn57642GraphicsScale3Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Maximum." ::= { wtWebGraphAnalogIn57642GraphicsScale 9 } wtWebGraphAnalogIn57642GraphicsScale4Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Maximum." ::= { wtWebGraphAnalogIn57642GraphicsScale 10 } wtWebGraphAnalogIn57642GraphicsScale1Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 1: Unit." ::= { wtWebGraphAnalogIn57642GraphicsScale 11 } wtWebGraphAnalogIn57642GraphicsScale2Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 2: Unit." ::= { wtWebGraphAnalogIn57642GraphicsScale 12 } wtWebGraphAnalogIn57642GraphicsScale3Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 3: Unit." ::= { wtWebGraphAnalogIn57642GraphicsScale 13 } wtWebGraphAnalogIn57642GraphicsScale4Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Scale 4: Unit." ::= { wtWebGraphAnalogIn57642GraphicsScale 14 } -- wtWebGraphAnalogIn57642Ports Group ---------------------------- -- Table wtWebGraphAnalogIn57642PortTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebGraphAnalogIn57642PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "List of settings depending on the sensor number." ::= { wtWebGraphAnalogIn57642Ports 1 } wtWebGraphAnalogIn57642PortEntry OBJECT-TYPE SYNTAX WtWebGraphAnalogIn57642PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sensor parameters for the individual sensors." INDEX { wtWebGraphAnalogIn57642SensorNo } ::= { wtWebGraphAnalogIn57642PortTable 1 } WtWebGraphAnalogIn57642PortEntry ::= SEQUENCE { wtWebGraphAnalogIn57642PortName OCTET STRING, wtWebGraphAnalogIn57642PortText OCTET STRING, wtWebGraphAnalogIn57642PortOffset1 OCTET STRING, wtWebGraphAnalogIn57642SetPoint1 OCTET STRING, wtWebGraphAnalogIn57642PortOffset2 OCTET STRING, wtWebGraphAnalogIn57642SetPoint2 OCTET STRING, wtWebGraphAnalogIn57642PortComment OCTET STRING, wtWebGraphAnalogIn57642PortSensorSelect OCTET STRING, wtWebGraphAnalogIn57642PortUnit OCTET STRING, wtWebGraphAnalogIn57642PortScale0 OCTET STRING, wtWebGraphAnalogIn57642PortScale100 OCTET STRING } wtWebGraphAnalogIn57642PortName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name of the sensor." ::= { wtWebGraphAnalogIn57642PortEntry 1 } wtWebGraphAnalogIn57642PortText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Description of the sensor." ::= { wtWebGraphAnalogIn57642PortEntry 2 } wtWebGraphAnalogIn57642PortOffset1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at set point 1." ::= { wtWebGraphAnalogIn57642PortEntry 3 } wtWebGraphAnalogIn57642SetPoint1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: set point 1 in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57642PortEntry 4 } wtWebGraphAnalogIn57642PortOffset2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: Offset in degrees with maximum 2 decimal places at set point 2." ::= { wtWebGraphAnalogIn57642PortEntry 5 } wtWebGraphAnalogIn57642SetPoint2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: set point 2 in degrees with maximum 2 decimal places." ::= { wtWebGraphAnalogIn57642PortEntry 6 } wtWebGraphAnalogIn57642PortComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset calibration: informations of date, name of operator, reference devices." ::= { wtWebGraphAnalogIn57642PortEntry 7 } wtWebGraphAnalogIn57642PortSensorSelect OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binary coded options for sensor 1: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-20mA (default) Bit 1 : 4-20mA Bit 2 : Disconnect Bit 3-7: unused Binary coded options for sensor 2: Octet 1: unused Octet 2: unused Octet 3: unused Octet 4: Bit 0 : 0-20mA (default) Bit 1 : 4-20mA Bit 2 : Disconnect Bit 3-7: unused" ::= { wtWebGraphAnalogIn57642PortEntry 8 } wtWebGraphAnalogIn57642PortUnit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed unit." ::= { wtWebGraphAnalogIn57642PortEntry 9 } wtWebGraphAnalogIn57642PortScale0 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed value in 1/1000 at 0% full scale range. Range: -999999.999 to 999999.999" ::= { wtWebGraphAnalogIn57642PortEntry 10 } wtWebGraphAnalogIn57642PortScale100 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "User scale: displayed value in 1/1000 at 100% full scale range. Range: -999999.999 to 999999.999" ::= { wtWebGraphAnalogIn57642PortEntry 11 } -- wtWebGraphAnalogIn57642Manufact Group ---------------------------- wtWebGraphAnalogIn57642MfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer company name" ::= { wtWebGraphAnalogIn57642Manufact 1 } wtWebGraphAnalogIn57642MfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer address." ::= { wtWebGraphAnalogIn57642Manufact 2 } wtWebGraphAnalogIn57642MfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer hotline." ::= { wtWebGraphAnalogIn57642Manufact 3 } wtWebGraphAnalogIn57642MfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer Internet address." ::= { wtWebGraphAnalogIn57642Manufact 4 } wtWebGraphAnalogIn57642MfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer device name (model number)." ::= { wtWebGraphAnalogIn57642Manufact 5 } wtWebGraphAnalogIn57642MfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Manufacturer part number." ::= { wtWebGraphAnalogIn57642Manufact 6 } -- wtWebGraphAnalogIn57642Diag Group ---------------------------- wtWebGraphAnalogIn57642DiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of entries in the error memory." ::= { wtWebGraphAnalogIn57642Diag 1 } wtWebGraphAnalogIn57642DiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Error causes coded bit-by-bit." ::= { wtWebGraphAnalogIn57642Diag 2 } wtWebGraphAnalogIn57642DiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable is used as an index to read an error massege from wtWebGraphAnalogIn57642DiagErrorMessage. Errors are numbered from 1 to wtWebGraphAnalogIn57642DiagErrorCount. Writing a valid value into this variable, making the appropriate message readable from wtWebGraphAnalogIn57642DiagErrorMessage." ::= { wtWebGraphAnalogIn57642Diag 3 } wtWebGraphAnalogIn57642DiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Using wtWebGraphAnalogIn57642DiagErrorIndex as an index, the appropriate message is available." ::= { wtWebGraphAnalogIn57642Diag 4 } wtWebGraphAnalogIn57642DiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Writing 1 into this variable clears all diagnosis messages." ::= { wtWebGraphAnalogIn57642Diag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebGraphAnalogIn57642Alert1 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 31 wtWebGraphAnalogIn57642Alert2 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 32 wtWebGraphAnalogIn57642Alert3 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 33 wtWebGraphAnalogIn57642Alert4 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 34 wtWebGraphAnalogIn57642Alert5 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 35 wtWebGraphAnalogIn57642Alert6 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 36 wtWebGraphAnalogIn57642Alert7 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 37 wtWebGraphAnalogIn57642Alert8 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 38 wtWebGraphAnalogIn57642Alert9 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 1 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 91 wtWebGraphAnalogIn57642Alert10 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 2 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 92 wtWebGraphAnalogIn57642Alert11 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 3 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 93 wtWebGraphAnalogIn57642Alert12 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 4 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 94 wtWebGraphAnalogIn57642Alert13 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 5 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 95 wtWebGraphAnalogIn57642Alert14 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 6 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 96 wtWebGraphAnalogIn57642Alert15 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 7 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 97 wtWebGraphAnalogIn57642Alert16 TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642AlarmClearTrapText } DESCRIPTION "This SNMP trap is generated when Alarm 8 was cleared, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 98 wtWebGraphAnalogIn57642AlertDiag TRAP-TYPE ENTERPRISE wtWebGraphAnalogIn57642 VARIABLES { wtWebGraphAnalogIn57642DiagErrorIndex, wtWebGraphAnalogIn57642DiagErrorMessage } DESCRIPTION "This SNMP trap is generated when a diagnosis/error message was triggered, SNMP trap enable is set and SNMP is enabled." -- NMS trap annotation --#TYPE "Thermo-Hygrometer Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 END