-- QTECH-PING-MIB.mib: Qtech Ping MIB file
--
-- March 2002, Wuzg
--
-- Copyright (c) 2002 by Qtech Networks Co.,Ltd.
-- All rights reserved.
--
-- *****************************************************************
--
QTECH-PING-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
IpAddress,
Unsigned32,
Integer32
FROM SNMPv2-SMI
TruthValue,
RowStatus
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
IfIndex
FROM QTECH-TC
qtechMgmt
FROM QTECH-SMI;
qtechPingMIB MODULE-IDENTITY
LAST-UPDATED "200203200000Z"
ORGANIZATION "Qtech Networks Co.,Ltd."
CONTACT-INFO
"
Tel: 4008-111-000
E-mail: service@qtech.com.cn"
DESCRIPTION
"This module defines qtech ping mibs."
REVISION "200203200000Z"
DESCRIPTION
"Initial version of this MIB module."
::= { qtechMgmt 3}
qtechPingMIBObjects OBJECT IDENTIFIER ::= { qtechPingMIB 1 }
qtechPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF QtechPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of ping request entries."
::= { qtechPingMIBObjects 1 }
qtechPingEntry OBJECT-TYPE
SYNTAX QtechPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry contains ping parameters and results.
A management station wishing to create an entry should
first generate a pseudo-random serial number to be used
as the index to a ping entry. The station should
then create the associated entry.
We must set all specifies valid values for the
non-defaulted configuration objects, certainly, it should
also modify the default values for the other configuration
objects if the defaults are not appropriate.
Once the appropriate instance of all the configuration
objects have been created or set,the row status should be set
to active to initiate the request.
Once the ping sequence has been activated, it cannot be
stopped -- it will run until the configured number of
packets have been sent.
Once the sequence completes, the management station should
retrieve the values of the status objects of interest, and
should then delete the entry. In order to prevent old
entries from clogging the table, entries will be aged out,
but an entry will never be deleted within 5 minutes of
completing."
INDEX { qtechPingIndex }
::= { qtechPingTable 1 }
QtechPingEntry ::=
SEQUENCE {
qtechPingIndex Integer32,
qtechPingAddress IpAddress,
qtechPingDataLength Unsigned32,
qtechPingTimes Unsigned32,
qtechPingTimeOuts Unsigned32,
qtechPingReturns Unsigned32,
qtechPingMaxTime Unsigned32,
qtechPingAvTime Unsigned32,
qtechPingMinTime Unsigned32,
qtechPingCompleted TruthValue,
qtechPingEntryStauts RowStatus,
qtechPingSourceIp IpAddress,
qtechPingSourceInterfaceIndex IfIndex,
qtechPingTypeOfService Unsigned32
}
qtechPingIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Object which specifies a unique entry in the
qtechPingTable. A management station wishing
to initiate a ping operation should use a
pseudo-random value for this object when creating
or modifying an instance of a qtechPingEntry.
The RowStatus semantics of the qtechPingEntryStatus
object will prevent access conflicts."
::= { qtechPingEntry 1 }
qtechPingAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Pinged host ip address."
::= { qtechPingEntry 2 }
qtechPingDataLength OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Pinged ICMP echo datagram's data length."
DEFVAL { 100 }
::= { qtechPingEntry 3 }
qtechPingTimes OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Pimes the ICMP echo datagrams will be sent."
DEFVAL { 5 }
::= { qtechPingEntry 4 }
qtechPingTimeOuts OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Ping but no echo from required address, the time last
for time out, in milliseconds."
DEFVAL { 2000 }
::= { qtechPingEntry 5 }
qtechPingReturns OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"How many echo request has been return by a echo reply."
::= { qtechPingEntry 6 }
qtechPingMaxTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Max return time of the echo reply."
::= { qtechPingEntry 7 }
qtechPingAvTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average returned time of the echo reply of that reply
but not time out."
::= { qtechPingEntry 8 }
qtechPingMinTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Min returned time of the echo reply."
::= { qtechPingEntry 9 }
qtechPingCompleted OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"While the ping process has completed the value of this field
will be true(1), else false(2)."
::= { qtechPingEntry 10 }
qtechPingEntryStauts OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"entry status for this list."
::= { qtechPingEntry 11 }
qtechPingSourceIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"the address of source interface."
::= { qtechPingEntry 12 }
qtechPingSourceInterfaceIndex OBJECT-TYPE
SYNTAX IfIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex value of this source interface."
::= { qtechPingEntry 13 }
qtechPingTypeOfService OBJECT-TYPE
SYNTAX Unsigned32(0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"the value of type of service."
::= { qtechPingEntry 14 }
-- conformance information
qtechPingMIBConformance OBJECT IDENTIFIER ::= { qtechPingMIB 2 }
qtechPingMIBCompliances OBJECT IDENTIFIER ::= { qtechPingMIBConformance 1 }
qtechPingMIBGroups OBJECT IDENTIFIER ::= { qtechPingMIBConformance 2 }
-- compliance statements
qtechPingMIBCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement
the Qtech Ping MIB"
MODULE -- this module
MANDATORY-GROUPS { qtechPingMIBGroup }
::= { qtechPingMIBCompliances 1 }
-- units of conformance
qtechPingMIBGroup OBJECT-GROUP
OBJECTS {
qtechPingIndex ,
qtechPingAddress ,
qtechPingDataLength ,
qtechPingTimes ,
qtechPingTimeOuts ,
qtechPingReturns ,
qtechPingMaxTime ,
qtechPingAvTime ,
qtechPingMinTime ,
qtechPingCompleted ,
qtechPingEntryStauts,
qtechPingSourceIp ,
qtechPingSourceInterfaceIndex ,
qtechPingTypeOfService
}
STATUS current
DESCRIPTION
"A collection of objects providing ping (echo) ability to a
Qtech agent."
::= { qtechPingMIBGroups 1 }
-- hcb add
traceRouteMIBObjects OBJECT IDENTIFIER ::= { qtechPingMIB 3 }
-- traceRouteTable
traceRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF TraceRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of trace route request entries.
The traceRouteTable will contain a set of
trace route requests that need to be executed
at the agent."
::= { traceRouteMIBObjects 1 }
-- traceRouteEntry
traceRouteEntry OBJECT-TYPE
SYNTAX TraceRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A trace route request entry."
INDEX { traceRouteIndex }
::= { traceRouteTable 1 }
TraceRouteEntry ::=
SEQUENCE {
traceRouteIndex Unsigned32,
traceRouteTargetAddr IpAddress,
traceRouteHopCount Unsigned32,
traceRoutePingCount Unsigned32,
traceRoutePingTimeout Unsigned32,
traceRouteRowStatus RowStatus
}
traceRouteIndex OBJECT-TYPE
SYNTAX Unsigned32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of a trace route entry. "
::= { traceRouteEntry 1 }
traceRouteTargetAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The address of the device to which the route is to be traced."
::= { traceRouteEntry 2 }
traceRouteHopCount OBJECT-TYPE
SYNTAX Unsigned32(1..100)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Wait timeout milliseconds for each reply."
DEFVAL { 30 }
::= { traceRouteEntry 3 }
traceRoutePingCount OBJECT-TYPE
SYNTAX Unsigned32(1..6)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Repeat count for each echo."
DEFVAL { 3 }
::= { traceRouteEntry 4 }
traceRoutePingTimeout OBJECT-TYPE
SYNTAX Unsigned32(1..60000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Wait timeout milliseconds for each reply."
DEFVAL { 2000 }
::= { traceRouteEntry 5 }
traceRouteRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"entry status for this list."
::= { traceRouteEntry 6 }
-- traceRouteHopsTable
traceRouteHopsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TraceRouteHopsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of trace route hop results.
This table contains the hop-by-hop result
of a trace route test performed for an
entry in the traceRouteTable."
::= { traceRouteMIBObjects 2 }
traceRouteHopsEntry OBJECT-TYPE
SYNTAX TraceRouteHopsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A trace route hop entry."
INDEX { traceRouteIndex, traceRouteHopIndex }
::= { traceRouteHopsTable 1 }
TraceRouteHopsEntry ::= SEQUENCE {
traceRouteHopIndex Unsigned32,
traceRouteHopPingIndex Unsigned32,
traceRouteHopPingCompleted TruthValue,
traceRouteHopPingResult TruthValue,
traceRouteHopPingReturnTime Unsigned32,
traceRouteHopAddr IpAddress
}
traceRouteHopIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the hop index for a
traceroute hop. Values for this object with
respect to the same traceRouteIndex MUST start
at 1 and increase monotonically.
All hops (traceRouteHopsTable entries) in a
trace route path MUST be updated at the same time
when a trace route test completes."
::= { traceRouteHopsEntry 1 }
traceRouteHopPingIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the hop index for a
Icmp echo. Values for this object with
respect to the same traceRouteIndex and
the same traceRouteHopIndex MUST start
at 1 and increase monotonically. "
::= { traceRouteHopsEntry 2 }
traceRouteHopPingCompleted OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"While the ping process has completed the value of this field
will be true(1), else false(2)."
::= { traceRouteHopsEntry 3 }
traceRouteHopPingResult OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"While the ping process has completed and
the Icmp echo reply or Icmp ttl expiration has received,
the value of this field will be true(1), else false(2)."
::= { traceRouteHopsEntry 4 }
traceRouteHopPingReturnTime OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returned time of the echo reply of that reply
but not time out."
::= { traceRouteHopsEntry 5 }
traceRouteHopAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object reports the WWN of the device
associated with this hop."
::= { traceRouteHopsEntry 6 }
END