-- ***************************************************************** -- QTECH-PING-MIB.mib: Qtech Ping MIB file -- -- March 2002, Wuzg -- -- Copyright (c) 2002 by Qtech Networks Co.,Ltd. -- All rights reserved. -- -- ***************************************************************** -- QTECH-PING-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, IpAddress, Unsigned32, Integer32 FROM SNMPv2-SMI TruthValue, RowStatus FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF IfIndex FROM QTECH-TC qtechMgmt FROM QTECH-SMI; qtechPingMIB MODULE-IDENTITY LAST-UPDATED "200203200000Z" ORGANIZATION "Qtech Networks Co.,Ltd." CONTACT-INFO " Tel: 4008-111-000 E-mail: service@qtech.com.cn" DESCRIPTION "This module defines qtech ping mibs." REVISION "200203200000Z" DESCRIPTION "Initial version of this MIB module." ::= { qtechMgmt 3} qtechPingMIBObjects OBJECT IDENTIFIER ::= { qtechPingMIB 1 } qtechPingTable OBJECT-TYPE SYNTAX SEQUENCE OF QtechPingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of ping request entries." ::= { qtechPingMIBObjects 1 } qtechPingEntry OBJECT-TYPE SYNTAX QtechPingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry contains ping parameters and results. A management station wishing to create an entry should first generate a pseudo-random serial number to be used as the index to a ping entry. The station should then create the associated entry. We must set all specifies valid values for the non-defaulted configuration objects, certainly, it should also modify the default values for the other configuration objects if the defaults are not appropriate. Once the appropriate instance of all the configuration objects have been created or set,the row status should be set to active to initiate the request. Once the ping sequence has been activated, it cannot be stopped -- it will run until the configured number of packets have been sent. Once the sequence completes, the management station should retrieve the values of the status objects of interest, and should then delete the entry. In order to prevent old entries from clogging the table, entries will be aged out, but an entry will never be deleted within 5 minutes of completing." INDEX { qtechPingIndex } ::= { qtechPingTable 1 } QtechPingEntry ::= SEQUENCE { qtechPingIndex Integer32, qtechPingAddress IpAddress, qtechPingDataLength Unsigned32, qtechPingTimes Unsigned32, qtechPingTimeOuts Unsigned32, qtechPingReturns Unsigned32, qtechPingMaxTime Unsigned32, qtechPingAvTime Unsigned32, qtechPingMinTime Unsigned32, qtechPingCompleted TruthValue, qtechPingEntryStauts RowStatus, qtechPingSourceIp IpAddress, qtechPingSourceInterfaceIndex IfIndex, qtechPingTypeOfService Unsigned32 } qtechPingIndex OBJECT-TYPE SYNTAX Integer32(1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Object which specifies a unique entry in the qtechPingTable. A management station wishing to initiate a ping operation should use a pseudo-random value for this object when creating or modifying an instance of a qtechPingEntry. The RowStatus semantics of the qtechPingEntryStatus object will prevent access conflicts." ::= { qtechPingEntry 1 } qtechPingAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Pinged host ip address." ::= { qtechPingEntry 2 } qtechPingDataLength OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Pinged ICMP echo datagram's data length." DEFVAL { 100 } ::= { qtechPingEntry 3 } qtechPingTimes OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Pimes the ICMP echo datagrams will be sent." DEFVAL { 5 } ::= { qtechPingEntry 4 } qtechPingTimeOuts OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "Ping but no echo from required address, the time last for time out, in milliseconds." DEFVAL { 2000 } ::= { qtechPingEntry 5 } qtechPingReturns OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "How many echo request has been return by a echo reply." ::= { qtechPingEntry 6 } qtechPingMaxTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Max return time of the echo reply." ::= { qtechPingEntry 7 } qtechPingAvTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Average returned time of the echo reply of that reply but not time out." ::= { qtechPingEntry 8 } qtechPingMinTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Min returned time of the echo reply." ::= { qtechPingEntry 9 } qtechPingCompleted OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "While the ping process has completed the value of this field will be true(1), else false(2)." ::= { qtechPingEntry 10 } qtechPingEntryStauts OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "entry status for this list." ::= { qtechPingEntry 11 } qtechPingSourceIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "the address of source interface." ::= { qtechPingEntry 12 } qtechPingSourceInterfaceIndex OBJECT-TYPE SYNTAX IfIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The ifIndex value of this source interface." ::= { qtechPingEntry 13 } qtechPingTypeOfService OBJECT-TYPE SYNTAX Unsigned32(0..255) MAX-ACCESS read-create STATUS current DESCRIPTION "the value of type of service." ::= { qtechPingEntry 14 } -- conformance information qtechPingMIBConformance OBJECT IDENTIFIER ::= { qtechPingMIB 2 } qtechPingMIBCompliances OBJECT IDENTIFIER ::= { qtechPingMIBConformance 1 } qtechPingMIBGroups OBJECT IDENTIFIER ::= { qtechPingMIBConformance 2 } -- compliance statements qtechPingMIBCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the Qtech Ping MIB" MODULE -- this module MANDATORY-GROUPS { qtechPingMIBGroup } ::= { qtechPingMIBCompliances 1 } -- units of conformance qtechPingMIBGroup OBJECT-GROUP OBJECTS { qtechPingIndex , qtechPingAddress , qtechPingDataLength , qtechPingTimes , qtechPingTimeOuts , qtechPingReturns , qtechPingMaxTime , qtechPingAvTime , qtechPingMinTime , qtechPingCompleted , qtechPingEntryStauts, qtechPingSourceIp , qtechPingSourceInterfaceIndex , qtechPingTypeOfService } STATUS current DESCRIPTION "A collection of objects providing ping (echo) ability to a Qtech agent." ::= { qtechPingMIBGroups 1 } -- hcb add traceRouteMIBObjects OBJECT IDENTIFIER ::= { qtechPingMIB 3 } -- traceRouteTable traceRouteTable OBJECT-TYPE SYNTAX SEQUENCE OF TraceRouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of trace route request entries. The traceRouteTable will contain a set of trace route requests that need to be executed at the agent." ::= { traceRouteMIBObjects 1 } -- traceRouteEntry traceRouteEntry OBJECT-TYPE SYNTAX TraceRouteEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A trace route request entry." INDEX { traceRouteIndex } ::= { traceRouteTable 1 } TraceRouteEntry ::= SEQUENCE { traceRouteIndex Unsigned32, traceRouteTargetAddr IpAddress, traceRouteHopCount Unsigned32, traceRoutePingCount Unsigned32, traceRoutePingTimeout Unsigned32, traceRouteRowStatus RowStatus } traceRouteIndex OBJECT-TYPE SYNTAX Unsigned32 (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of a trace route entry. " ::= { traceRouteEntry 1 } traceRouteTargetAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The address of the device to which the route is to be traced." ::= { traceRouteEntry 2 } traceRouteHopCount OBJECT-TYPE SYNTAX Unsigned32(1..100) MAX-ACCESS read-create STATUS current DESCRIPTION "Wait timeout milliseconds for each reply." DEFVAL { 30 } ::= { traceRouteEntry 3 } traceRoutePingCount OBJECT-TYPE SYNTAX Unsigned32(1..6) MAX-ACCESS read-create STATUS current DESCRIPTION "Repeat count for each echo." DEFVAL { 3 } ::= { traceRouteEntry 4 } traceRoutePingTimeout OBJECT-TYPE SYNTAX Unsigned32(1..60000) MAX-ACCESS read-create STATUS current DESCRIPTION "Wait timeout milliseconds for each reply." DEFVAL { 2000 } ::= { traceRouteEntry 5 } traceRouteRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "entry status for this list." ::= { traceRouteEntry 6 } -- traceRouteHopsTable traceRouteHopsTable OBJECT-TYPE SYNTAX SEQUENCE OF TraceRouteHopsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of trace route hop results. This table contains the hop-by-hop result of a trace route test performed for an entry in the traceRouteTable." ::= { traceRouteMIBObjects 2 } traceRouteHopsEntry OBJECT-TYPE SYNTAX TraceRouteHopsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A trace route hop entry." INDEX { traceRouteIndex, traceRouteHopIndex } ::= { traceRouteHopsTable 1 } TraceRouteHopsEntry ::= SEQUENCE { traceRouteHopIndex Unsigned32, traceRouteHopPingIndex Unsigned32, traceRouteHopPingCompleted TruthValue, traceRouteHopPingResult TruthValue, traceRouteHopPingReturnTime Unsigned32, traceRouteHopAddr IpAddress } traceRouteHopIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the hop index for a traceroute hop. Values for this object with respect to the same traceRouteIndex MUST start at 1 and increase monotonically. All hops (traceRouteHopsTable entries) in a trace route path MUST be updated at the same time when a trace route test completes." ::= { traceRouteHopsEntry 1 } traceRouteHopPingIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object specifies the hop index for a Icmp echo. Values for this object with respect to the same traceRouteIndex and the same traceRouteHopIndex MUST start at 1 and increase monotonically. " ::= { traceRouteHopsEntry 2 } traceRouteHopPingCompleted OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "While the ping process has completed the value of this field will be true(1), else false(2)." ::= { traceRouteHopsEntry 3 } traceRouteHopPingResult OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "While the ping process has completed and the Icmp echo reply or Icmp ttl expiration has received, the value of this field will be true(1), else false(2)." ::= { traceRouteHopsEntry 4 } traceRouteHopPingReturnTime OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Returned time of the echo reply of that reply but not time out." ::= { traceRouteHopsEntry 5 } traceRouteHopAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object reports the WWN of the device associated with this hop." ::= { traceRouteHopsEntry 6 } END