DMOS-HW-MONITOR-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, TruthValue, DisplayString
|
|
FROM SNMPv2-TC
|
|
datacomDevicesMIBs
|
|
FROM DATACOM-SMI
|
|
UnsignedPercent
|
|
FROM DMOS-TC-MIB;
|
|
|
|
dmosHwMonitorMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201701020000Z"
|
|
ORGANIZATION "DATACOM"
|
|
CONTACT-INFO
|
|
"DATACOM
|
|
|
|
Postal: DATACOM
|
|
Rua America, 1000
|
|
Eldorado do Sul, RS
|
|
CEP 92990-000
|
|
BRAZIL
|
|
|
|
Tel:+55(51)3933 3000
|
|
Fax:+55(51)3933 3003
|
|
|
|
E-mail: datacom@datacom.ind.br"
|
|
DESCRIPTION "This module contains DmOS thermal information and status monitoring objects."
|
|
REVISION "201701020000Z"
|
|
DESCRIPTION "First revision"
|
|
::= { datacomDevicesMIBs 6 }
|
|
|
|
EnvironmentSensorTemperature ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d-1"
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
SYNTAX Integer32
|
|
|
|
EnvironmentSensorStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
SYNTAX INTEGER {fail(-2),error(-1),normal(0),high(1),low(2),critical(3)}
|
|
|
|
environment OBJECT IDENTIFIER ::= { dmosHwMonitorMIB 1 }
|
|
|
|
environmentChassisTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EnvironmentChassisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "List of chassis for which thermal management information is available"
|
|
::= { environment 1 }
|
|
|
|
environmentChassisEntry OBJECT-TYPE
|
|
SYNTAX EnvironmentChassisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Chassis identification field"
|
|
INDEX { environmentChassisId }
|
|
::= { environmentChassisTable 1 }
|
|
|
|
EnvironmentChassisEntry ::=
|
|
SEQUENCE {
|
|
environmentChassisId Unsigned32
|
|
}
|
|
|
|
environmentChassisId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Chassis identifier"
|
|
::= { environmentChassisEntry 1 }
|
|
|
|
environmentSlotTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EnvironmentSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "List of slots for which thermal management information is available"
|
|
::= { environment 2 }
|
|
|
|
environmentSlotEntry OBJECT-TYPE
|
|
SYNTAX EnvironmentSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Slot thermal information structure"
|
|
INDEX { environmentChassisId, environmentSlotId }
|
|
::= { environmentSlotTable 1 }
|
|
|
|
EnvironmentSlotEntry ::=
|
|
SEQUENCE {
|
|
environmentSlotId DisplayString
|
|
}
|
|
|
|
environmentSlotId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot identifier"
|
|
::= { environmentSlotEntry 1 }
|
|
|
|
temperatureSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TemperatureSensorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "List of temperature sensors present on a given slot and chassis"
|
|
::= { environment 3 }
|
|
|
|
temperatureSensorEntry OBJECT-TYPE
|
|
SYNTAX TemperatureSensorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Temperature sensor information structure"
|
|
INDEX { environmentChassisId, environmentSlotId, temperatureSensorId }
|
|
::= { temperatureSensorTable 1 }
|
|
|
|
TemperatureSensorEntry ::=
|
|
SEQUENCE {
|
|
temperatureSensorId DisplayString,
|
|
temperatureSensorDescription DisplayString,
|
|
temperatureSensorMaxTemperature EnvironmentSensorTemperature,
|
|
temperatureSensorMinTemperature EnvironmentSensorTemperature,
|
|
temperatureSensorHysteresis EnvironmentSensorTemperature,
|
|
temperatureSensorCurrentTemperature EnvironmentSensorTemperature,
|
|
temperatureSensorTemperatureReadError TruthValue,
|
|
temperatureSensorTemperatureStatus EnvironmentSensorStatus
|
|
}
|
|
|
|
temperatureSensorId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Temperature sensor identifier"
|
|
::= { temperatureSensorEntry 1 }
|
|
|
|
temperatureSensorDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature sensor description"
|
|
::= { temperatureSensorEntry 2 }
|
|
|
|
temperatureSensorMaxTemperature OBJECT-TYPE
|
|
SYNTAX EnvironmentSensorTemperature
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "High temperature alarm threshold"
|
|
::= { temperatureSensorEntry 3 }
|
|
|
|
temperatureSensorMinTemperature OBJECT-TYPE
|
|
SYNTAX EnvironmentSensorTemperature
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Low temperature alarm threshold"
|
|
::= { temperatureSensorEntry 4 }
|
|
|
|
temperatureSensorHysteresis OBJECT-TYPE
|
|
SYNTAX EnvironmentSensorTemperature
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hysteresis value for both high and low temperature alarms"
|
|
::= { temperatureSensorEntry 5 }
|
|
|
|
temperatureSensorCurrentTemperature OBJECT-TYPE
|
|
SYNTAX EnvironmentSensorTemperature
|
|
UNITS "C"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current temperature value being read by the sensor"
|
|
::= { temperatureSensorEntry 6 }
|
|
|
|
temperatureSensorTemperatureReadError OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates if an error occured while trying to read from the sensor"
|
|
::= { temperatureSensorEntry 7 }
|
|
|
|
temperatureSensorTemperatureStatus OBJECT-TYPE
|
|
SYNTAX EnvironmentSensorStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature status based on minimum and maximum thresholds"
|
|
::= { temperatureSensorEntry 8 }
|
|
|
|
fanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "List of individual fans manageable on a given fan module/slot"
|
|
::= { environment 4 }
|
|
|
|
fanEntry OBJECT-TYPE
|
|
SYNTAX FanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Fan information structure"
|
|
INDEX { environmentChassisId, environmentSlotId, fanId }
|
|
::= { fanTable 1 }
|
|
|
|
FanEntry ::=
|
|
SEQUENCE {
|
|
fanId DisplayString,
|
|
fanDescription DisplayString,
|
|
fanControl UnsignedPercent,
|
|
fanSpeed Unsigned32,
|
|
fanSpeedReadError TruthValue,
|
|
fanSpeedStatus EnvironmentSensorStatus
|
|
}
|
|
|
|
fanId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Fan identifier"
|
|
::= { fanEntry 1 }
|
|
|
|
fanDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Fan description"
|
|
::= { fanEntry 2 }
|
|
|
|
fanControl OBJECT-TYPE
|
|
SYNTAX UnsignedPercent
|
|
UNITS "%"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Percentage of maximum fan speed applied for thermal control"
|
|
::= { fanEntry 3 }
|
|
|
|
fanSpeed OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "RPM"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Current speed of the fan"
|
|
::= { fanEntry 4 }
|
|
|
|
fanSpeedReadError OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates if an error occured while trying to read from the sensor"
|
|
::= { fanEntry 5 }
|
|
|
|
fanSpeedStatus OBJECT-TYPE
|
|
SYNTAX EnvironmentSensorStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the current state of the fan based on its speed"
|
|
::= { fanEntry 6 }
|
|
|
|
psuTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PsuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "List of Power Supply Units"
|
|
::= { environment 5}
|
|
|
|
psuEntry OBJECT-TYPE
|
|
SYNTAX PsuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Power Supply Unit information structure"
|
|
INDEX { IMPLIED psuId }
|
|
::= { psuTable 1 }
|
|
|
|
PsuEntry ::=
|
|
SEQUENCE {
|
|
psuId DisplayString,
|
|
psuStatus INTEGER
|
|
}
|
|
|
|
psuId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Power Supply Unit identifier"
|
|
::= { psuEntry 1 }
|
|
|
|
psuStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {ok(0),powerInputFailure(1),fuseFailure(2),error(3)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the current state of the PSU"
|
|
::= { psuEntry 2 }
|
|
|
|
END
|