DMOS-HW-MONITOR-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32 FROM SNMPv2-SMI TEXTUAL-CONVENTION, TruthValue, DisplayString FROM SNMPv2-TC datacomDevicesMIBs FROM DATACOM-SMI UnsignedPercent FROM DMOS-TC-MIB; dmosHwMonitorMIB MODULE-IDENTITY LAST-UPDATED "201701020000Z" ORGANIZATION "DATACOM" CONTACT-INFO "DATACOM Postal: DATACOM Rua America, 1000 Eldorado do Sul, RS CEP 92990-000 BRAZIL Tel:+55(51)3933 3000 Fax:+55(51)3933 3003 E-mail: datacom@datacom.ind.br" DESCRIPTION "This module contains DmOS thermal information and status monitoring objects." REVISION "201701020000Z" DESCRIPTION "First revision" ::= { datacomDevicesMIBs 6 } EnvironmentSensorTemperature ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-1" STATUS current DESCRIPTION "" SYNTAX Integer32 EnvironmentSensorStatus ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "" SYNTAX INTEGER {fail(-2),error(-1),normal(0),high(1),low(2),critical(3)} environment OBJECT IDENTIFIER ::= { dmosHwMonitorMIB 1 } environmentChassisTable OBJECT-TYPE SYNTAX SEQUENCE OF EnvironmentChassisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of chassis for which thermal management information is available" ::= { environment 1 } environmentChassisEntry OBJECT-TYPE SYNTAX EnvironmentChassisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Chassis identification field" INDEX { environmentChassisId } ::= { environmentChassisTable 1 } EnvironmentChassisEntry ::= SEQUENCE { environmentChassisId Unsigned32 } environmentChassisId OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis identifier" ::= { environmentChassisEntry 1 } environmentSlotTable OBJECT-TYPE SYNTAX SEQUENCE OF EnvironmentSlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of slots for which thermal management information is available" ::= { environment 2 } environmentSlotEntry OBJECT-TYPE SYNTAX EnvironmentSlotEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Slot thermal information structure" INDEX { environmentChassisId, environmentSlotId } ::= { environmentSlotTable 1 } EnvironmentSlotEntry ::= SEQUENCE { environmentSlotId DisplayString } environmentSlotId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Slot identifier" ::= { environmentSlotEntry 1 } temperatureSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF TemperatureSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of temperature sensors present on a given slot and chassis" ::= { environment 3 } temperatureSensorEntry OBJECT-TYPE SYNTAX TemperatureSensorEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Temperature sensor information structure" INDEX { environmentChassisId, environmentSlotId, temperatureSensorId } ::= { temperatureSensorTable 1 } TemperatureSensorEntry ::= SEQUENCE { temperatureSensorId DisplayString, temperatureSensorDescription DisplayString, temperatureSensorMaxTemperature EnvironmentSensorTemperature, temperatureSensorMinTemperature EnvironmentSensorTemperature, temperatureSensorHysteresis EnvironmentSensorTemperature, temperatureSensorCurrentTemperature EnvironmentSensorTemperature, temperatureSensorTemperatureReadError TruthValue, temperatureSensorTemperatureStatus EnvironmentSensorStatus } temperatureSensorId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS not-accessible STATUS current DESCRIPTION "Temperature sensor identifier" ::= { temperatureSensorEntry 1 } temperatureSensorDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature sensor description" ::= { temperatureSensorEntry 2 } temperatureSensorMaxTemperature OBJECT-TYPE SYNTAX EnvironmentSensorTemperature UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "High temperature alarm threshold" ::= { temperatureSensorEntry 3 } temperatureSensorMinTemperature OBJECT-TYPE SYNTAX EnvironmentSensorTemperature UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "Low temperature alarm threshold" ::= { temperatureSensorEntry 4 } temperatureSensorHysteresis OBJECT-TYPE SYNTAX EnvironmentSensorTemperature UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "Hysteresis value for both high and low temperature alarms" ::= { temperatureSensorEntry 5 } temperatureSensorCurrentTemperature OBJECT-TYPE SYNTAX EnvironmentSensorTemperature UNITS "C" MAX-ACCESS read-only STATUS current DESCRIPTION "Current temperature value being read by the sensor" ::= { temperatureSensorEntry 6 } temperatureSensorTemperatureReadError OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if an error occured while trying to read from the sensor" ::= { temperatureSensorEntry 7 } temperatureSensorTemperatureStatus OBJECT-TYPE SYNTAX EnvironmentSensorStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature status based on minimum and maximum thresholds" ::= { temperatureSensorEntry 8 } fanTable OBJECT-TYPE SYNTAX SEQUENCE OF FanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of individual fans manageable on a given fan module/slot" ::= { environment 4 } fanEntry OBJECT-TYPE SYNTAX FanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fan information structure" INDEX { environmentChassisId, environmentSlotId, fanId } ::= { fanTable 1 } FanEntry ::= SEQUENCE { fanId DisplayString, fanDescription DisplayString, fanControl UnsignedPercent, fanSpeed Unsigned32, fanSpeedReadError TruthValue, fanSpeedStatus EnvironmentSensorStatus } fanId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS not-accessible STATUS current DESCRIPTION "Fan identifier" ::= { fanEntry 1 } fanDescription OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Fan description" ::= { fanEntry 2 } fanControl OBJECT-TYPE SYNTAX UnsignedPercent UNITS "%" MAX-ACCESS read-only STATUS current DESCRIPTION "Percentage of maximum fan speed applied for thermal control" ::= { fanEntry 3 } fanSpeed OBJECT-TYPE SYNTAX Unsigned32 UNITS "RPM" MAX-ACCESS read-only STATUS current DESCRIPTION "Current speed of the fan" ::= { fanEntry 4 } fanSpeedReadError OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if an error occured while trying to read from the sensor" ::= { fanEntry 5 } fanSpeedStatus OBJECT-TYPE SYNTAX EnvironmentSensorStatus MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current state of the fan based on its speed" ::= { fanEntry 6 } psuTable OBJECT-TYPE SYNTAX SEQUENCE OF PsuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of Power Supply Units" ::= { environment 5} psuEntry OBJECT-TYPE SYNTAX PsuEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power Supply Unit information structure" INDEX { IMPLIED psuId } ::= { psuTable 1 } PsuEntry ::= SEQUENCE { psuId DisplayString, psuStatus INTEGER } psuId OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS not-accessible STATUS current DESCRIPTION "Power Supply Unit identifier" ::= { psuEntry 1 } psuStatus OBJECT-TYPE SYNTAX INTEGER {ok(0),powerInputFailure(1),fuseFailure(2),error(3)} MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the current state of the PSU" ::= { psuEntry 2 } END