-- genWtnMonitor.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 2.1 Build 205
-- Tuesday, June 12, 2001 at 09:35:59
--
ZHONE-GEN-WTN-MONITOR-MIB DEFINITIONS ::= BEGIN
IMPORTS
SnmpAdminString
FROM SNMP-FRAMEWORK-MIB
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
FROM SNMPv2-SMI
zhoneGenWtn, zhoneModules
FROM Zhone;
--
zhoneGenWtnMonitorModule MODULE-IDENTITY
LAST-UPDATED "0009281216Z"
ORGANIZATION
"Zhone Technologies, Inc."
CONTACT-INFO
" Postal:
Zhone Technologies, Inc.
@ Zhone Way
7001 Oakport Street
Oakland, CA 94621
USA
Toll-Free: +1 877-ZHONE20 (+1 877-946-6320)
Tel: +1-510-777-7000
Fax: +1-510-777-7001
E-mail: support@zhone.com"
DESCRIPTION
"Module for wireless transport node (ZWT)
variables which report general system status."
REVISION "0105252136Z"
DESCRIPTION
"V01.01.00 - Removed ACO related objects.
Using SkyZhone_Stats_Profile."
::= { zhoneModules 102 }
--
-- Node definitions
--
wtnMonitor OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Collection of monitored elements for each wireless transport node."
::= { zhoneGenWtn 1 }
wtnLedStatus OBJECT-TYPE
SYNTAX BITS
{
diag(0),
operational(1),
lineInterface(2),
radio(3),
local(4),
remote(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reflects current state of LEDs of indoor unit.
A bit value of 1 indicates the LED is ON.
A bit value of 0 indicates the LED of OFF.
Meaning of LEDs:
===========================================
diag -
Upon power up the LED is turned on. If the unit
successfully passes diagnostics, the LED is turned off.
When operational, the LED is turned on when diagnostics
are performed or when the system detects an alarm.
operational -
Upon power up the LED is off. When the system is
operating it is turned on.
The actual LED is blinked when the ZMS link is down
or during software download.
lineInterface -
This LED is turned on when there are no wire-line alarms.
For SkyZhone45 - this refers to the DS3 line.
For SkyZhone155 - this refers to the fiber.
For SkyZhone8e - this refers to the set of T1/E1 lines.
radio -
This LED is turned on when there are no radio receive alarms.
local-
This LED is turned on when there are not alarms present
on the Near End indoor or outdoor units.
remote -
This LED is turned on when there are not alarms present
on the Far End indoor or outdoor units."
::= { wtnMonitor 1 }
wtnAlarmStatus OBJECT-TYPE
SYNTAX BITS
{
minorAlarm(0),
criticalAlarm(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm Contact Status.
minorAlarm(0) - when active, a minor alarm condition is present
criticalAlarm(1) - when active, a critical alarm condition is present.
On power up all alarms contacts are open/inactive (0)."
::= { wtnMonitor 2 }
radioLinkConfiguration OBJECT-IDENTITY
STATUS current
DESCRIPTION
"Description."
::= { zhoneGenWtn 2 }
wtnLinkName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Textual description which identifies link.
A link is comprised of this and another SkyZhone
node at the far end."
::= { radioLinkConfiguration 1 }
END
--
-- genWtnMonitor.mib
--