-- genWtnMonitor.mib
|
|
-- MIB generated by MG-SOFT Visual MIB Builder Version 2.1 Build 205
|
|
-- Tuesday, June 12, 2001 at 09:35:59
|
|
--
|
|
|
|
ZHONE-GEN-WTN-MONITOR-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
OBJECT-TYPE, MODULE-IDENTITY, OBJECT-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
zhoneGenWtn, zhoneModules
|
|
FROM Zhone;
|
|
|
|
|
|
--
|
|
zhoneGenWtnMonitorModule MODULE-IDENTITY
|
|
LAST-UPDATED "0009281216Z"
|
|
ORGANIZATION
|
|
"Zhone Technologies, Inc."
|
|
CONTACT-INFO
|
|
" Postal:
|
|
Zhone Technologies, Inc.
|
|
@ Zhone Way
|
|
7001 Oakport Street
|
|
Oakland, CA 94621
|
|
USA
|
|
Toll-Free: +1 877-ZHONE20 (+1 877-946-6320)
|
|
Tel: +1-510-777-7000
|
|
Fax: +1-510-777-7001
|
|
E-mail: support@zhone.com"
|
|
DESCRIPTION
|
|
"Module for wireless transport node (ZWT)
|
|
variables which report general system status."
|
|
REVISION "0105252136Z"
|
|
DESCRIPTION
|
|
"V01.01.00 - Removed ACO related objects.
|
|
Using SkyZhone_Stats_Profile."
|
|
::= { zhoneModules 102 }
|
|
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
wtnMonitor OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Collection of monitored elements for each wireless transport node."
|
|
::= { zhoneGenWtn 1 }
|
|
|
|
wtnLedStatus OBJECT-TYPE
|
|
SYNTAX BITS
|
|
{
|
|
diag(0),
|
|
operational(1),
|
|
lineInterface(2),
|
|
radio(3),
|
|
local(4),
|
|
remote(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reflects current state of LEDs of indoor unit.
|
|
A bit value of 1 indicates the LED is ON.
|
|
A bit value of 0 indicates the LED of OFF.
|
|
|
|
Meaning of LEDs:
|
|
===========================================
|
|
diag -
|
|
Upon power up the LED is turned on. If the unit
|
|
successfully passes diagnostics, the LED is turned off.
|
|
When operational, the LED is turned on when diagnostics
|
|
are performed or when the system detects an alarm.
|
|
|
|
operational -
|
|
Upon power up the LED is off. When the system is
|
|
operating it is turned on.
|
|
The actual LED is blinked when the ZMS link is down
|
|
or during software download.
|
|
|
|
lineInterface -
|
|
This LED is turned on when there are no wire-line alarms.
|
|
For SkyZhone45 - this refers to the DS3 line.
|
|
For SkyZhone155 - this refers to the fiber.
|
|
For SkyZhone8e - this refers to the set of T1/E1 lines.
|
|
|
|
radio -
|
|
This LED is turned on when there are no radio receive alarms.
|
|
|
|
local-
|
|
This LED is turned on when there are not alarms present
|
|
on the Near End indoor or outdoor units.
|
|
|
|
remote -
|
|
This LED is turned on when there are not alarms present
|
|
on the Far End indoor or outdoor units."
|
|
::= { wtnMonitor 1 }
|
|
|
|
wtnAlarmStatus OBJECT-TYPE
|
|
SYNTAX BITS
|
|
{
|
|
minorAlarm(0),
|
|
criticalAlarm(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm Contact Status.
|
|
minorAlarm(0) - when active, a minor alarm condition is present
|
|
criticalAlarm(1) - when active, a critical alarm condition is present.
|
|
|
|
On power up all alarms contacts are open/inactive (0)."
|
|
::= { wtnMonitor 2 }
|
|
|
|
radioLinkConfiguration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description."
|
|
::= { zhoneGenWtn 2 }
|
|
|
|
wtnLinkName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Textual description which identifies link.
|
|
A link is comprised of this and another SkyZhone
|
|
node at the far end."
|
|
::= { radioLinkConfiguration 1 }
|
|
|
|
|
|