FORT-TELECOM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
OBJECT-IDENTITY,
|
|
NOTIFICATION-TYPE,
|
|
enterprises FROM SNMPv2-SMI;
|
|
|
|
|
|
|
|
forttelecomMIB MODULE-IDENTITY
|
|
|
|
LAST-UPDATED "202008260000Z" -- Aug 26, 2020
|
|
|
|
ORGANIZATION "Fort-Telecom Ltd."
|
|
|
|
CONTACT-INFO "
|
|
Editor: Belyaev Alexandr
|
|
Fort-Telecom Ltd.
|
|
Tel: 8-800-100-112-8
|
|
E-mail: abelyaev@fort-telecom.ru
|
|
"
|
|
|
|
DESCRIPTION
|
|
"The MIB module for managing TFortis switch.
|
|
Copyright (c) Fort-Telecom (2020)."
|
|
|
|
REVISION "202008260000Z" -- Aug 26, 2020
|
|
DESCRIPTION "Fort-Telecom MIB"
|
|
|
|
::= { enterprises 42019 }
|
|
|
|
switch OBJECT IDENTIFIER ::= { forttelecomMIB 3 }
|
|
integrations OBJECT IDENTIFIER ::= { forttelecomMIB 4 }
|
|
psw OBJECT IDENTIFIER ::= { switch 2}
|
|
teleport OBJECT IDENTIFIER ::= { integrations 2}
|
|
|
|
-- TRAPS Group
|
|
trapsPSW OBJECT IDENTIFIER ::= { psw 0}
|
|
trapsTLP OBJECT IDENTIFIER ::= { teleport 0}
|
|
|
|
-- SET Group
|
|
configPSW OBJECT IDENTIFIER ::= { psw 1}
|
|
|
|
|
|
-- STATUS Group
|
|
statusPSW OBJECT IDENTIFIER ::= { psw 2}
|
|
|
|
|
|
|
|
-- Set/Config Groups for Switches
|
|
-- Comfort Start set Group
|
|
comfortStart OBJECT IDENTIFIER ::= { configPSW 1}
|
|
|
|
comfortStartTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Comfort Start Time (in Hours)"
|
|
::= { comfortStart 1 }
|
|
|
|
comfStartTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ComfStartEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { comfortStart 2 }
|
|
|
|
comfStartEntry OBJECT-TYPE
|
|
SYNTAX ComfStartEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the comfStartTable."
|
|
INDEX { comfStIndex }
|
|
::= { comfStartTable 1 }
|
|
|
|
ComfStartEntry ::= SEQUENCE {
|
|
comfStIndex INTEGER,
|
|
comfStState INTEGER
|
|
}
|
|
|
|
|
|
comfStIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { comfStartEntry 1 }
|
|
|
|
comfStState OBJECT-TYPE
|
|
SYNTAX INTEGER { enabled(1), disabled(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { comfStartEntry 2 }
|
|
|
|
|
|
-- Auto ReStart set Group
|
|
autoRestart OBJECT IDENTIFIER ::= { configPSW 2}
|
|
|
|
autoRestartTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AutoRestartEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { autoRestart 1 }
|
|
|
|
autoRestartEntry OBJECT-TYPE
|
|
SYNTAX AutoRestartEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the autoRestartTable."
|
|
INDEX { autoRstIndex }
|
|
::= { autoRestartTable 1 }
|
|
|
|
AutoRestartEntry ::= SEQUENCE {
|
|
autoRstIndex INTEGER,
|
|
autoRstMode INTEGER,
|
|
autoRstDstIP IpAddress,
|
|
autoRstSpeedDown INTEGER,
|
|
autoRstSpeedUp INTEGER
|
|
}
|
|
|
|
autoRstIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { autoRestartEntry 1 }
|
|
|
|
autoRstMode OBJECT-TYPE
|
|
SYNTAX INTEGER { link(1),ping(2),speed(3),time(4),disabled(0) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mode of Auto Restart controller"
|
|
::= { autoRestartEntry 2 }
|
|
|
|
autoRstDstIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of device"
|
|
::= { autoRestartEntry 3 }
|
|
|
|
autoRstSpeedDown OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lower level of speed"
|
|
::= { autoRestartEntry 4 }
|
|
|
|
autoRstSpeedUp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Upper level of speed"
|
|
::= { autoRestartEntry 5 }
|
|
|
|
autoReStartTimeOnHour OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hour of PoE Enable"
|
|
::= { autoRestartEntry 6 }
|
|
|
|
autoReStartTimeOnMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minute of PoE Enable"
|
|
::= { autoRestartEntry 7 }
|
|
|
|
autoReStartTimeOffHour OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hour of PoE Disable"
|
|
::= { autoRestartEntry 8 }
|
|
|
|
autoReStartTimeOffMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minute of PoE Disable"
|
|
::= { autoRestartEntry 9 }
|
|
|
|
-- PoE set Group
|
|
portPoe OBJECT IDENTIFIER ::= { configPSW 3}
|
|
|
|
portPoeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PortPoeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { portPoe 1 }
|
|
|
|
portPoeEntry OBJECT-TYPE
|
|
SYNTAX PortPoeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the portPoeTable."
|
|
INDEX { portPoeIndex }
|
|
::= { portPoeTable 1 }
|
|
|
|
PortPoeEntry ::= SEQUENCE {
|
|
portPoeIndex INTEGER,
|
|
portPoeState INTEGER
|
|
}
|
|
|
|
|
|
portPoeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port Number"
|
|
::= { portPoeEntry 1 }
|
|
|
|
portPoeState OBJECT-TYPE
|
|
SYNTAX INTEGER { enabled(1), disabled(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PoE State"
|
|
::= { portPoeEntry 2 }
|
|
|
|
|
|
|
|
-- Output Relay State
|
|
outStatePSW OBJECT IDENTIFIER ::= { configPSW 4}
|
|
|
|
state OBJECT-TYPE
|
|
SYNTAX INTEGER { open(1), short(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output Relay State"
|
|
::= { outStatePSW 1 }
|
|
|
|
-- Traps group for Switches
|
|
|
|
stpTopologyChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "STP Topology changed events occur"
|
|
::= { trapsPSW 1}
|
|
|
|
|
|
|
|
specialFunctionNoLink NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates no link activity at activated
|
|
SpecialFunctions by criterion a link"
|
|
::= { trapsPSW 2}
|
|
|
|
specialFunctionNoPingResponse NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates no ping response at activated
|
|
SpecialFunctions by criterion a ping"
|
|
::= { trapsPSW 3}
|
|
|
|
specialFunctionLowSpeed NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Notification indicates low speed on port at activated
|
|
SpecialFunctions by criterion a speed"
|
|
::= { trapsPSW 4}
|
|
|
|
|
|
|
|
updateFirmware NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates a firmwre updating"
|
|
::= { trapsPSW 5}
|
|
|
|
|
|
setToDefault NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Settings to default"
|
|
::= { trapsPSW 6}
|
|
|
|
|
|
backupSettings NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Make backup copy of settings in file"
|
|
::= { trapsPSW 7}
|
|
|
|
|
|
systemWarmStart NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start system after reboot"
|
|
::= { trapsPSW 8}
|
|
|
|
systemColdStart NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start system after power down (Cold start)"
|
|
::= { trapsPSW 9}
|
|
|
|
webInterfaceLoginOk NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Successfully authentification on web-interface"
|
|
::= { trapsPSW 10}
|
|
|
|
webInterfaceLoginFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fail authentification on web-interface"
|
|
::= { trapsPSW 11}
|
|
|
|
emptyArpTable NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Arp table is empty"
|
|
::= { trapsPSW 12}
|
|
|
|
|
|
|
|
upsLowVoltage NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UPS: Voltage on battery is low (below than 44V)"
|
|
::= { trapsPSW 13}
|
|
|
|
upsBattrtyPower NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UPS: Power souce is battery"
|
|
::= { trapsPSW 14}
|
|
|
|
upsVacPower NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UPS: Power souce is external VAC"
|
|
::= { trapsPSW 15}
|
|
|
|
|
|
|
|
--asc group (SKUD)
|
|
tamperIsActive NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sensor 0 (Tamper) is active."
|
|
::= { trapsPSW 16}
|
|
|
|
sensor1isActive NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sensor 1 (dry contact) is active"
|
|
::= { trapsPSW 17}
|
|
|
|
sensor2isActive NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sensor 2 (dry contact) is active"
|
|
::= { trapsPSW 18}
|
|
|
|
input1isActive NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 1 is active"
|
|
::= { trapsPSW 19}
|
|
|
|
input2isActive NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 2 is active"
|
|
::= { trapsPSW 20}
|
|
|
|
input3isActive NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 3 is active"
|
|
::= { trapsPSW 21}
|
|
|
|
input4isActive NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 4 is active"
|
|
::= { trapsPSW 22}
|
|
|
|
|
|
|
|
macFilteringAlarm NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unallowed MAC address: "
|
|
::= { trapsPSW 23}
|
|
|
|
portErrorDisabled NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port Error-Disabled"
|
|
::= { trapsPSW 24}
|
|
|
|
pwr180DiagnosticError NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The error of the PWR-180 power supply was diagnosed, check the power supply"
|
|
::= { trapsPSW 25}
|
|
|
|
|
|
temperatureSensorLow NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "Temperature: low level"
|
|
::= { trapsPSW 26}
|
|
|
|
temperatureSensorHigh NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "Temperature: high level"
|
|
::= { trapsPSW 27}
|
|
|
|
humiditySensorLow NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "Humidity: low level"
|
|
::= { trapsPSW 28}
|
|
|
|
humiditySensorHigh NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Humidity: high level"
|
|
::= { trapsPSW 29}
|
|
|
|
leakageSensorAlarm NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Leakage sensor is active: 1 - Normal, 2 - Alarm"
|
|
::= { trapsPSW 30}
|
|
|
|
|
|
-- Status group for Switches
|
|
-- UPS status group
|
|
upsStatus OBJECT IDENTIFIER ::= { statusPSW 1}
|
|
|
|
upsModeAvalible OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UPS option is avalible. 'true' for switches with UPS module."
|
|
::= { upsStatus 1 }
|
|
|
|
upsPwrSource OBJECT-TYPE
|
|
SYNTAX INTEGER { battery(1), ac(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable shows the power source for switch. 'Battery' - power source is battery,
|
|
no external AC voltage. 'AC' - power source is external AC voltage,normal operation.
|
|
This option only for switches with UPS module."
|
|
::= { upsStatus 2 }
|
|
|
|
upsBatteryVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable shows battery voltage. This option only for switches with UPS module."
|
|
::= { upsStatus 3 }
|
|
|
|
upsBatteryTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable shows estimated operating time (in sec.) of the device after switching to battery power (only for devices with UPS module)."
|
|
::= { upsStatus 4 }
|
|
|
|
-- Inputs status group
|
|
inputStatus OBJECT IDENTIFIER ::= { statusPSW 2}
|
|
|
|
inputStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InputStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { inputStatus 1 }
|
|
|
|
inputStatusEntry OBJECT-TYPE
|
|
SYNTAX InputStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the portPoeTable."
|
|
INDEX { inputIndex }
|
|
::= { inputStatusTable 1 }
|
|
|
|
InputStatusEntry ::= SEQUENCE {
|
|
inputIndex INTEGER,
|
|
inputType INTEGER,
|
|
inputState INTEGER,
|
|
inputAlarm INTEGER
|
|
}
|
|
|
|
|
|
inputIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input Number"
|
|
::= { inputStatusEntry 1 }
|
|
|
|
inputType OBJECT-TYPE
|
|
SYNTAX INTEGER{ build-in(1), plc(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input Type: 'buil-in' - inputs on main board, 'plc' - inputs on optional board"
|
|
::= { inputStatusEntry 2 }
|
|
|
|
inputState OBJECT-TYPE
|
|
SYNTAX INTEGER{ short(1), open(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input State"
|
|
::= { inputStatusEntry 3 }
|
|
|
|
inputAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER{ short(1), open(2), any(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm state condition"
|
|
::= { inputStatusEntry 4 }
|
|
|
|
-- Firmware status group
|
|
fwStatus OBJECT IDENTIFIER ::= { statusPSW 3}
|
|
|
|
fwVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firmware version"
|
|
::= { fwStatus 1 }
|
|
|
|
-- Energy meter group
|
|
emStatus OBJECT IDENTIFIER ::= { statusPSW 4}
|
|
|
|
emConnectionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { true(1), false(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Energy meter connection status. 'true' if EM is connected via RS845 and option board (PLC)
|
|
is avalible."
|
|
::= { emStatus 1 }
|
|
|
|
emResultTotal OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable shows total indication of Energy meter, if EM is connected."
|
|
::= { emStatus 2 }
|
|
|
|
emResultT1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable shows indication T1 of Energy meter, if EM is connected."
|
|
::= { emStatus 3 }
|
|
|
|
emResultT2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable shows indication T2 of Energy meter, if EM is connected."
|
|
::= { emStatus 4 }
|
|
|
|
emResultT3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable shows indication T3 of Energy meter, if EM is connected."
|
|
::= { emStatus 5 }
|
|
|
|
emResultT4 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable shows indication T4 of Energy meter, if EM is connected."
|
|
::= { emStatus 6 }
|
|
|
|
emPollingInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable shows polling interval of Energy meter in minutes. Counters
|
|
emResultTotal, emResultT1, emResultT2, emResultT3, emResultT4 updated with
|
|
the same interval."
|
|
::= { emStatus 7 }
|
|
|
|
|
|
-- PoE status group
|
|
PoeStatusEntry ::= SEQUENCE {
|
|
portPoeStatusIndex INTEGER,
|
|
portPoeStatusState INTEGER,
|
|
portPoeStatusPower INTEGER
|
|
}
|
|
|
|
poeStatus OBJECT IDENTIFIER ::= { statusPSW 5}
|
|
|
|
poeStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PoeStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { poeStatus 1 }
|
|
|
|
poeStatusEntry OBJECT-TYPE
|
|
SYNTAX PoeStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the portPoeTable."
|
|
INDEX { portPoeStatusIndex }
|
|
::= { poeStatusTable 1 }
|
|
|
|
|
|
|
|
|
|
portPoeStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port Number"
|
|
::= { poeStatusEntry 1 }
|
|
|
|
portPoeStatusState OBJECT-TYPE
|
|
SYNTAX INTEGER { up(1), down(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PoE State"
|
|
::= { poeStatusEntry 2 }
|
|
|
|
portPoeStatusPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PoE load power (in mW) "
|
|
::= { poeStatusEntry 3 }
|
|
|
|
-- Special Funtion status group
|
|
specialStatus OBJECT IDENTIFIER ::= { statusPSW 6}
|
|
|
|
-- Auto Restart Errors
|
|
AutoRestartErrorsEntry ::= SEQUENCE {
|
|
arPortIndex INTEGER,
|
|
arPortStatus INTEGER
|
|
}
|
|
|
|
autoRestartErrors OBJECT IDENTIFIER ::= { specialStatus 1}
|
|
|
|
autoRestartErrorsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AutoRestartErrorsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { autoRestartErrors 1 }
|
|
|
|
|
|
|
|
autoRestartErrorsEntry OBJECT-TYPE
|
|
SYNTAX AutoRestartErrorsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the autoRestartErrorsTable."
|
|
INDEX { arPortIndex }
|
|
::= { autoRestartErrorsTable 1 }
|
|
|
|
|
|
|
|
arPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port Number"
|
|
::= { autoRestartErrorsEntry 1 }
|
|
|
|
arPortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(1), noLink(2), noPing(3), lowSpeed(4) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of special function 'AutoRestart'.
|
|
'normal' - no error,
|
|
'noLink' - no link activity on port,
|
|
'noPing' - no answer to ping,
|
|
'lowSpeed' - low speed on port"
|
|
::= { autoRestartErrorsEntry 2 }
|
|
|
|
|
|
-- Comfort start Status
|
|
comfortStartStatus OBJECT IDENTIFIER ::= { specialStatus 2}
|
|
|
|
comfortStartStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ComfortStartStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { comfortStartStatus 1 }
|
|
|
|
|
|
|
|
comfortStartStatusEntry OBJECT-TYPE
|
|
SYNTAX ComfortStartStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the comfortStartStatusTable."
|
|
INDEX { csPortIndex }
|
|
::= { comfortStartStatusTable 1 }
|
|
|
|
ComfortStartStatusEntry ::= SEQUENCE {
|
|
csPortIndex INTEGER,
|
|
csPortStatus INTEGER
|
|
}
|
|
|
|
|
|
csPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port Number"
|
|
::= { comfortStartStatusEntry 1 }
|
|
|
|
csPortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(1), processing(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of special function 'ComfortStart' on port.
|
|
'normal' - ComfortStart is ready,
|
|
'processing' - ComfortStart in processing"
|
|
::= { comfortStartStatusEntry 2 }
|
|
|
|
|
|
-- SFP modules status group
|
|
SfpStatusEntry ::= SEQUENCE {
|
|
portSfpIndex INTEGER,
|
|
portSfpPresent INTEGER,
|
|
portSfpSignalDetect INTEGER,
|
|
portSfpVendor OCTET STRING,
|
|
portSfpOui OCTET STRING,
|
|
portSfpPartNumber OCTET STRING,
|
|
portSfpRevision OCTET STRING,
|
|
portSfpTemperature INTEGER,
|
|
portSfpVoltage INTEGER,
|
|
portSfpBiasCurrent INTEGER,
|
|
portSfpTxOutPower INTEGER,
|
|
portSfpTxOutPowerDb INTEGER,
|
|
portSfpRxOutPower INTEGER,
|
|
portSfpRxOutPowerDb INTEGER
|
|
}
|
|
sfpStatus OBJECT IDENTIFIER ::= { statusPSW 7}
|
|
|
|
sfpStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SfpStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { sfpStatus 1 }
|
|
|
|
sfpStatusEntry OBJECT-TYPE
|
|
SYNTAX SfpStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the sfpStatusTable."
|
|
INDEX { portSfpIndex }
|
|
::= { sfpStatusTable 1 }
|
|
|
|
portSfpIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP port number"
|
|
::= { sfpStatusEntry 1 }
|
|
|
|
portSfpPresent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Present of SFP module in the case"
|
|
::= { sfpStatusEntry 2 }
|
|
|
|
portSfpSignalDetect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Optical Signal Detect of SFP module"
|
|
::= { sfpStatusEntry 3 }
|
|
|
|
portSfpVendor OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP module Vendor"
|
|
::= { sfpStatusEntry 4 }
|
|
|
|
portSfpOui OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP module Vendor OUI"
|
|
::= { sfpStatusEntry 5 }
|
|
|
|
portSfpPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP module Part Number"
|
|
::= { sfpStatusEntry 6 }
|
|
|
|
portSfpRevision OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP module Revision"
|
|
::= { sfpStatusEntry 7 }
|
|
|
|
portSfpTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature of SFP module. In degrees Celsius"
|
|
::= { sfpStatusEntry 8 }
|
|
|
|
portSfpVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voltage in SFP module (mV)"
|
|
::= { sfpStatusEntry 9 }
|
|
|
|
portSfpBiasCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TX bias current (uA)"
|
|
::= { sfpStatusEntry 10 }
|
|
|
|
portSfpTxOutPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TX output optical power (uW)"
|
|
::= { sfpStatusEntry 11 }
|
|
|
|
portSfpTxOutPowerDb OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TX output optical power (dB)"
|
|
::= { sfpStatusEntry 12 }
|
|
|
|
portSfpRxOutPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RX output optical power (uW)"
|
|
::= { sfpStatusEntry 13 }
|
|
|
|
portSfpRxOutPowerDb OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RX output optical power (dB)"
|
|
::= { sfpStatusEntry 14 }
|
|
|
|
|
|
-- Temperature/Humidity sensor group
|
|
SensorEntry ::= SEQUENCE {
|
|
sensorConnected INTEGER,
|
|
sensorTemperature INTEGER,
|
|
sensorHumidity INTEGER
|
|
}
|
|
sensorEntry OBJECT IDENTIFIER ::= { statusPSW 8}
|
|
sensorConnected OBJECT-TYPE
|
|
SYNTAX INTEGER { connected(1), disconnected(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Connection status of temperature/humidity sensor"
|
|
::= { sensorEntry 1 }
|
|
|
|
sensorTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Temperature value"
|
|
::= { sensorEntry 2 }
|
|
|
|
sensorHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Humidity value"
|
|
::= { sensorEntry 3 }
|
|
|
|
|
|
-- Parts for Teleport
|
|
-- Set/Config Groups
|
|
-- Traps group
|
|
updateFirmwareTLP NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates a firmwre updating"
|
|
::= { trapsTLP 1}
|
|
|
|
|
|
setToDefaultTLP NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Settings to default"
|
|
::= { trapsTLP 2}
|
|
|
|
|
|
backupSettingsTLP NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Make backup copy of settings in file"
|
|
::= { trapsTLP 3}
|
|
|
|
|
|
systemWarmStartTLP NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start system after reboot"
|
|
::= { trapsTLP 4}
|
|
|
|
systemColdStartTLP NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start system after power down (Cold start)"
|
|
::= { trapsTLP 5}
|
|
|
|
webInterfaceLoginOkTLP NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Successfully authentification on web-interface"
|
|
::= { trapsTLP 6}
|
|
|
|
webInterfaceLoginFailTLP NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fail authentification on web-interface"
|
|
::= { trapsTLP 7}
|
|
|
|
emptyArpTableTLP NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Arp table is empty"
|
|
::= { trapsTLP 8}
|
|
|
|
|
|
|
|
input1isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 1 is changed"
|
|
::= { trapsTLP 9}
|
|
|
|
input2isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 2 is changed"
|
|
::= { trapsTLP 10}
|
|
|
|
input3isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 3 is changed"
|
|
::= { trapsTLP 11}
|
|
|
|
input4isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 4 is changed"
|
|
::= { trapsTLP 12}
|
|
|
|
input5isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 5 is changed"
|
|
::= { trapsTLP 13}
|
|
|
|
input6isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 6 is changed"
|
|
::= { trapsTLP 14}
|
|
|
|
input7isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 7 is changed"
|
|
::= { trapsTLP 15}
|
|
|
|
input8isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 8 is changed"
|
|
::= { trapsTLP 16}
|
|
|
|
input9isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input 9 is changed"
|
|
::= { trapsTLP 17}
|
|
|
|
output1isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output 1 is changed"
|
|
::= { trapsTLP 18}
|
|
|
|
output2isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output 2 is changed"
|
|
::= { trapsTLP 19}
|
|
|
|
output3isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output 3 is changed"
|
|
::= { trapsTLP 20}
|
|
|
|
output4isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output 4 is changed"
|
|
::= { trapsTLP 21}
|
|
|
|
output5isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output 5 is changed"
|
|
::= { trapsTLP 22}
|
|
|
|
output6isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output 6 is changed"
|
|
::= { trapsTLP 23}
|
|
|
|
output7isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output 7 is changed"
|
|
::= { trapsTLP 24}
|
|
|
|
output8isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output 8 is changed"
|
|
::= { trapsTLP 25}
|
|
|
|
output9isChanged NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Output 9 is changed"
|
|
::= { trapsTLP 26}
|
|
|
|
device1connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 1 connection fail"
|
|
::= { trapsTLP 27}
|
|
|
|
device2connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 2 connection fail"
|
|
::= { trapsTLP 28}
|
|
|
|
device3connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 3 connection fail"
|
|
::= { trapsTLP 29}
|
|
|
|
device4connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 4 connection fail"
|
|
::= { trapsTLP 30}
|
|
|
|
device5connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 5 connection fail"
|
|
::= { trapsTLP 31}
|
|
|
|
device6connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 6 connection fail"
|
|
::= { trapsTLP 32}
|
|
|
|
device7connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 7 connection fail"
|
|
::= { trapsTLP 33}
|
|
|
|
device8connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 8 connection fail"
|
|
::= { trapsTLP 34}
|
|
|
|
device9connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 9 connection fail"
|
|
::= { trapsTLP 35}
|
|
|
|
device10connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 10 connection fail"
|
|
::= { trapsTLP 36}
|
|
|
|
device11connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 11 connection fail"
|
|
::= { trapsTLP 37}
|
|
|
|
device12connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 12 connection fail"
|
|
::= { trapsTLP 38}
|
|
|
|
device13connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 13 connection fail"
|
|
::= { trapsTLP 39}
|
|
|
|
device14connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 14 connection fail"
|
|
::= { trapsTLP 40}
|
|
|
|
device15connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 15 connection fail"
|
|
::= { trapsTLP 41}
|
|
|
|
device16connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 16 connection fail"
|
|
::= { trapsTLP 42}
|
|
|
|
device17connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 17 connection fail"
|
|
::= { trapsTLP 43}
|
|
|
|
device18connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 18 connection fail"
|
|
::= { trapsTLP 44}
|
|
|
|
device19connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 19 connection fail"
|
|
::= { trapsTLP 45}
|
|
|
|
device20connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 20 connection fail"
|
|
::= { trapsTLP 46}
|
|
|
|
device21connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 21 connection fail"
|
|
::= { trapsTLP 47}
|
|
|
|
device22connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 22 connection fail"
|
|
::= { trapsTLP 48}
|
|
|
|
device23connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 23 connection fail"
|
|
::= { trapsTLP 49}
|
|
|
|
device24connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 24 connection fail"
|
|
::= { trapsTLP 50}
|
|
|
|
device25connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 25 connection fail"
|
|
::= { trapsTLP 51}
|
|
|
|
device26connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 26 connection fail"
|
|
::= { trapsTLP 52}
|
|
|
|
device27connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 27 connection fail"
|
|
::= { trapsTLP 53}
|
|
|
|
device28connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 28 connection fail"
|
|
::= { trapsTLP 54}
|
|
|
|
device29connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 29 connection fail"
|
|
::= { trapsTLP 55}
|
|
|
|
device30connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 30 connection fail"
|
|
::= { trapsTLP 56}
|
|
|
|
device31connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 31 connection fail"
|
|
::= { trapsTLP 57}
|
|
|
|
device32connFail NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device 32 connection fail"
|
|
::= { trapsTLP 58}
|
|
|
|
|
|
-- Status/Config group
|
|
|
|
-- Inputs status group
|
|
inputTeleport OBJECT IDENTIFIER ::= { teleport 2}
|
|
|
|
inputStatusTableTLP OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InputStatusEntryTLP
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { inputTeleport 1 }
|
|
|
|
inputStatusEntryTLP OBJECT-TYPE
|
|
SYNTAX InputStatusEntryTLP
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) ."
|
|
INDEX { inputIndexTLP }
|
|
::= { inputStatusTableTLP 1 }
|
|
|
|
InputStatusEntryTLP ::= SEQUENCE {
|
|
inputIndexTLP INTEGER,
|
|
inputStateTLP INTEGER
|
|
}
|
|
|
|
inputIndexTLP OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input Number"
|
|
::= { inputStatusEntryTLP 1 }
|
|
|
|
|
|
inputStateTLP OBJECT-TYPE
|
|
SYNTAX INTEGER{ open(1), short(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input State"
|
|
::= { inputStatusEntryTLP 2 }
|
|
|
|
-- Output Status/Config Group
|
|
outputTeleport OBJECT IDENTIFIER ::= { teleport 3}
|
|
|
|
outputTeleportTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutputTeleportEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { outputTeleport 1 }
|
|
|
|
outputTeleportEntry OBJECT-TYPE
|
|
SYNTAX OutputTeleportEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry (conceptual row) in the outputTeleportTable."
|
|
INDEX { outIndex }
|
|
::= { outputTeleportTable 1 }
|
|
|
|
OutputTeleportEntry ::= SEQUENCE {
|
|
outIndex INTEGER,
|
|
outState INTEGER
|
|
}
|
|
|
|
|
|
outIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of Output"
|
|
::= { outputTeleportEntry 1 }
|
|
|
|
outState OBJECT-TYPE
|
|
SYNTAX INTEGER { open(1), short(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of Output"
|
|
::= { outputTeleportEntry 2 }
|
|
|
|
|
|
-- Firmware status group
|
|
fwStatusTLP OBJECT IDENTIFIER ::= { teleport 4}
|
|
|
|
fwVersionTLP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firmware version"
|
|
::= { fwStatusTLP 1 }
|
|
|
|
END
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|