Observium_CE/mibs/tfortis/FORT-TELECOM-MIB

1421 lines
34 KiB
Plaintext

FORT-TELECOM-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
OBJECT-IDENTITY,
NOTIFICATION-TYPE,
enterprises FROM SNMPv2-SMI;
forttelecomMIB MODULE-IDENTITY
LAST-UPDATED "202008260000Z" -- Aug 26, 2020
ORGANIZATION "Fort-Telecom Ltd."
CONTACT-INFO "
Editor: Belyaev Alexandr
Fort-Telecom Ltd.
Tel: 8-800-100-112-8
E-mail: abelyaev@fort-telecom.ru
"
DESCRIPTION
"The MIB module for managing TFortis switch.
Copyright (c) Fort-Telecom (2020)."
REVISION "202008260000Z" -- Aug 26, 2020
DESCRIPTION "Fort-Telecom MIB"
::= { enterprises 42019 }
switch OBJECT IDENTIFIER ::= { forttelecomMIB 3 }
integrations OBJECT IDENTIFIER ::= { forttelecomMIB 4 }
psw OBJECT IDENTIFIER ::= { switch 2}
teleport OBJECT IDENTIFIER ::= { integrations 2}
-- TRAPS Group
trapsPSW OBJECT IDENTIFIER ::= { psw 0}
trapsTLP OBJECT IDENTIFIER ::= { teleport 0}
-- SET Group
configPSW OBJECT IDENTIFIER ::= { psw 1}
-- STATUS Group
statusPSW OBJECT IDENTIFIER ::= { psw 2}
-- Set/Config Groups for Switches
-- Comfort Start set Group
comfortStart OBJECT IDENTIFIER ::= { configPSW 1}
comfortStartTime OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Comfort Start Time (in Hours)"
::= { comfortStart 1 }
comfStartTable OBJECT-TYPE
SYNTAX SEQUENCE OF ComfStartEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { comfortStart 2 }
comfStartEntry OBJECT-TYPE
SYNTAX ComfStartEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the comfStartTable."
INDEX { comfStIndex }
::= { comfStartTable 1 }
ComfStartEntry ::= SEQUENCE {
comfStIndex INTEGER,
comfStState INTEGER
}
comfStIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { comfStartEntry 1 }
comfStState OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { comfStartEntry 2 }
-- Auto ReStart set Group
autoRestart OBJECT IDENTIFIER ::= { configPSW 2}
autoRestartTable OBJECT-TYPE
SYNTAX SEQUENCE OF AutoRestartEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { autoRestart 1 }
autoRestartEntry OBJECT-TYPE
SYNTAX AutoRestartEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the autoRestartTable."
INDEX { autoRstIndex }
::= { autoRestartTable 1 }
AutoRestartEntry ::= SEQUENCE {
autoRstIndex INTEGER,
autoRstMode INTEGER,
autoRstDstIP IpAddress,
autoRstSpeedDown INTEGER,
autoRstSpeedUp INTEGER
}
autoRstIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { autoRestartEntry 1 }
autoRstMode OBJECT-TYPE
SYNTAX INTEGER { link(1),ping(2),speed(3),time(4),disabled(0) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mode of Auto Restart controller"
::= { autoRestartEntry 2 }
autoRstDstIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP address of device"
::= { autoRestartEntry 3 }
autoRstSpeedDown OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Lower level of speed"
::= { autoRestartEntry 4 }
autoRstSpeedUp OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Upper level of speed"
::= { autoRestartEntry 5 }
autoReStartTimeOnHour OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hour of PoE Enable"
::= { autoRestartEntry 6 }
autoReStartTimeOnMin OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minute of PoE Enable"
::= { autoRestartEntry 7 }
autoReStartTimeOffHour OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hour of PoE Disable"
::= { autoRestartEntry 8 }
autoReStartTimeOffMin OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minute of PoE Disable"
::= { autoRestartEntry 9 }
-- PoE set Group
portPoe OBJECT IDENTIFIER ::= { configPSW 3}
portPoeTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortPoeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { portPoe 1 }
portPoeEntry OBJECT-TYPE
SYNTAX PortPoeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the portPoeTable."
INDEX { portPoeIndex }
::= { portPoeTable 1 }
PortPoeEntry ::= SEQUENCE {
portPoeIndex INTEGER,
portPoeState INTEGER
}
portPoeIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Number"
::= { portPoeEntry 1 }
portPoeState OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"PoE State"
::= { portPoeEntry 2 }
-- Output Relay State
outStatePSW OBJECT IDENTIFIER ::= { configPSW 4}
state OBJECT-TYPE
SYNTAX INTEGER { open(1), short(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output Relay State"
::= { outStatePSW 1 }
-- Traps group for Switches
stpTopologyChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION "STP Topology changed events occur"
::= { trapsPSW 1}
specialFunctionNoLink NOTIFICATION-TYPE
STATUS current
DESCRIPTION
" This Notification indicates no link activity at activated
SpecialFunctions by criterion a link"
::= { trapsPSW 2}
specialFunctionNoPingResponse NOTIFICATION-TYPE
STATUS current
DESCRIPTION
" This Notification indicates no ping response at activated
SpecialFunctions by criterion a ping"
::= { trapsPSW 3}
specialFunctionLowSpeed NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This Notification indicates low speed on port at activated
SpecialFunctions by criterion a speed"
::= { trapsPSW 4}
updateFirmware NOTIFICATION-TYPE
STATUS current
DESCRIPTION
" This Notification indicates a firmwre updating"
::= { trapsPSW 5}
setToDefault NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Settings to default"
::= { trapsPSW 6}
backupSettings NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Make backup copy of settings in file"
::= { trapsPSW 7}
systemWarmStart NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Start system after reboot"
::= { trapsPSW 8}
systemColdStart NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Start system after power down (Cold start)"
::= { trapsPSW 9}
webInterfaceLoginOk NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Successfully authentification on web-interface"
::= { trapsPSW 10}
webInterfaceLoginFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Fail authentification on web-interface"
::= { trapsPSW 11}
emptyArpTable NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Arp table is empty"
::= { trapsPSW 12}
upsLowVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"UPS: Voltage on battery is low (below than 44V)"
::= { trapsPSW 13}
upsBattrtyPower NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"UPS: Power souce is battery"
::= { trapsPSW 14}
upsVacPower NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"UPS: Power souce is external VAC"
::= { trapsPSW 15}
--asc group (SKUD)
tamperIsActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sensor 0 (Tamper) is active."
::= { trapsPSW 16}
sensor1isActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sensor 1 (dry contact) is active"
::= { trapsPSW 17}
sensor2isActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sensor 2 (dry contact) is active"
::= { trapsPSW 18}
input1isActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 1 is active"
::= { trapsPSW 19}
input2isActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 2 is active"
::= { trapsPSW 20}
input3isActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 3 is active"
::= { trapsPSW 21}
input4isActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 4 is active"
::= { trapsPSW 22}
macFilteringAlarm NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Unallowed MAC address: "
::= { trapsPSW 23}
portErrorDisabled NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Port Error-Disabled"
::= { trapsPSW 24}
pwr180DiagnosticError NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The error of the PWR-180 power supply was diagnosed, check the power supply"
::= { trapsPSW 25}
temperatureSensorLow NOTIFICATION-TYPE
STATUS current
DESCRIPTION "Temperature: low level"
::= { trapsPSW 26}
temperatureSensorHigh NOTIFICATION-TYPE
STATUS current
DESCRIPTION "Temperature: high level"
::= { trapsPSW 27}
humiditySensorLow NOTIFICATION-TYPE
STATUS current
DESCRIPTION "Humidity: low level"
::= { trapsPSW 28}
humiditySensorHigh NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Humidity: high level"
::= { trapsPSW 29}
leakageSensorAlarm NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Leakage sensor is active: 1 - Normal, 2 - Alarm"
::= { trapsPSW 30}
-- Status group for Switches
-- UPS status group
upsStatus OBJECT IDENTIFIER ::= { statusPSW 1}
upsModeAvalible OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"UPS option is avalible. 'true' for switches with UPS module."
::= { upsStatus 1 }
upsPwrSource OBJECT-TYPE
SYNTAX INTEGER { battery(1), ac(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable shows the power source for switch. 'Battery' - power source is battery,
no external AC voltage. 'AC' - power source is external AC voltage,normal operation.
This option only for switches with UPS module."
::= { upsStatus 2 }
upsBatteryVoltage OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable shows battery voltage. This option only for switches with UPS module."
::= { upsStatus 3 }
upsBatteryTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable shows estimated operating time (in sec.) of the device after switching to battery power (only for devices with UPS module)."
::= { upsStatus 4 }
-- Inputs status group
inputStatus OBJECT IDENTIFIER ::= { statusPSW 2}
inputStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF InputStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { inputStatus 1 }
inputStatusEntry OBJECT-TYPE
SYNTAX InputStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the portPoeTable."
INDEX { inputIndex }
::= { inputStatusTable 1 }
InputStatusEntry ::= SEQUENCE {
inputIndex INTEGER,
inputType INTEGER,
inputState INTEGER,
inputAlarm INTEGER
}
inputIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input Number"
::= { inputStatusEntry 1 }
inputType OBJECT-TYPE
SYNTAX INTEGER{ build-in(1), plc(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input Type: 'buil-in' - inputs on main board, 'plc' - inputs on optional board"
::= { inputStatusEntry 2 }
inputState OBJECT-TYPE
SYNTAX INTEGER{ short(1), open(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input State"
::= { inputStatusEntry 3 }
inputAlarm OBJECT-TYPE
SYNTAX INTEGER{ short(1), open(2), any(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm state condition"
::= { inputStatusEntry 4 }
-- Firmware status group
fwStatus OBJECT IDENTIFIER ::= { statusPSW 3}
fwVersion OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Firmware version"
::= { fwStatus 1 }
-- Energy meter group
emStatus OBJECT IDENTIFIER ::= { statusPSW 4}
emConnectionStatus OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Energy meter connection status. 'true' if EM is connected via RS845 and option board (PLC)
is avalible."
::= { emStatus 1 }
emResultTotal OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable shows total indication of Energy meter, if EM is connected."
::= { emStatus 2 }
emResultT1 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable shows indication T1 of Energy meter, if EM is connected."
::= { emStatus 3 }
emResultT2 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable shows indication T2 of Energy meter, if EM is connected."
::= { emStatus 4 }
emResultT3 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable shows indication T3 of Energy meter, if EM is connected."
::= { emStatus 5 }
emResultT4 OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable shows indication T4 of Energy meter, if EM is connected."
::= { emStatus 6 }
emPollingInterval OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable shows polling interval of Energy meter in minutes. Counters
emResultTotal, emResultT1, emResultT2, emResultT3, emResultT4 updated with
the same interval."
::= { emStatus 7 }
-- PoE status group
PoeStatusEntry ::= SEQUENCE {
portPoeStatusIndex INTEGER,
portPoeStatusState INTEGER,
portPoeStatusPower INTEGER
}
poeStatus OBJECT IDENTIFIER ::= { statusPSW 5}
poeStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PoeStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { poeStatus 1 }
poeStatusEntry OBJECT-TYPE
SYNTAX PoeStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the portPoeTable."
INDEX { portPoeStatusIndex }
::= { poeStatusTable 1 }
portPoeStatusIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Number"
::= { poeStatusEntry 1 }
portPoeStatusState OBJECT-TYPE
SYNTAX INTEGER { up(1), down(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PoE State"
::= { poeStatusEntry 2 }
portPoeStatusPower OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PoE load power (in mW) "
::= { poeStatusEntry 3 }
-- Special Funtion status group
specialStatus OBJECT IDENTIFIER ::= { statusPSW 6}
-- Auto Restart Errors
AutoRestartErrorsEntry ::= SEQUENCE {
arPortIndex INTEGER,
arPortStatus INTEGER
}
autoRestartErrors OBJECT IDENTIFIER ::= { specialStatus 1}
autoRestartErrorsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AutoRestartErrorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { autoRestartErrors 1 }
autoRestartErrorsEntry OBJECT-TYPE
SYNTAX AutoRestartErrorsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the autoRestartErrorsTable."
INDEX { arPortIndex }
::= { autoRestartErrorsTable 1 }
arPortIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Number"
::= { autoRestartErrorsEntry 1 }
arPortStatus OBJECT-TYPE
SYNTAX INTEGER { normal(1), noLink(2), noPing(3), lowSpeed(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of special function 'AutoRestart'.
'normal' - no error,
'noLink' - no link activity on port,
'noPing' - no answer to ping,
'lowSpeed' - low speed on port"
::= { autoRestartErrorsEntry 2 }
-- Comfort start Status
comfortStartStatus OBJECT IDENTIFIER ::= { specialStatus 2}
comfortStartStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ComfortStartStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { comfortStartStatus 1 }
comfortStartStatusEntry OBJECT-TYPE
SYNTAX ComfortStartStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the comfortStartStatusTable."
INDEX { csPortIndex }
::= { comfortStartStatusTable 1 }
ComfortStartStatusEntry ::= SEQUENCE {
csPortIndex INTEGER,
csPortStatus INTEGER
}
csPortIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port Number"
::= { comfortStartStatusEntry 1 }
csPortStatus OBJECT-TYPE
SYNTAX INTEGER { normal(1), processing(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of special function 'ComfortStart' on port.
'normal' - ComfortStart is ready,
'processing' - ComfortStart in processing"
::= { comfortStartStatusEntry 2 }
-- SFP modules status group
SfpStatusEntry ::= SEQUENCE {
portSfpIndex INTEGER,
portSfpPresent INTEGER,
portSfpSignalDetect INTEGER,
portSfpVendor OCTET STRING,
portSfpOui OCTET STRING,
portSfpPartNumber OCTET STRING,
portSfpRevision OCTET STRING,
portSfpTemperature INTEGER,
portSfpVoltage INTEGER,
portSfpBiasCurrent INTEGER,
portSfpTxOutPower INTEGER,
portSfpTxOutPowerDb INTEGER,
portSfpRxOutPower INTEGER,
portSfpRxOutPowerDb INTEGER
}
sfpStatus OBJECT IDENTIFIER ::= { statusPSW 7}
sfpStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SfpStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { sfpStatus 1 }
sfpStatusEntry OBJECT-TYPE
SYNTAX SfpStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the sfpStatusTable."
INDEX { portSfpIndex }
::= { sfpStatusTable 1 }
portSfpIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SFP port number"
::= { sfpStatusEntry 1 }
portSfpPresent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Present of SFP module in the case"
::= { sfpStatusEntry 2 }
portSfpSignalDetect OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Optical Signal Detect of SFP module"
::= { sfpStatusEntry 3 }
portSfpVendor OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SFP module Vendor"
::= { sfpStatusEntry 4 }
portSfpOui OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SFP module Vendor OUI"
::= { sfpStatusEntry 5 }
portSfpPartNumber OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SFP module Part Number"
::= { sfpStatusEntry 6 }
portSfpRevision OBJECT-TYPE
SYNTAX DisplayString ( SIZE ( 0 .. 255 ) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SFP module Revision"
::= { sfpStatusEntry 7 }
portSfpTemperature OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of SFP module. In degrees Celsius"
::= { sfpStatusEntry 8 }
portSfpVoltage OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Voltage in SFP module (mV)"
::= { sfpStatusEntry 9 }
portSfpBiasCurrent OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TX bias current (uA)"
::= { sfpStatusEntry 10 }
portSfpTxOutPower OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TX output optical power (uW)"
::= { sfpStatusEntry 11 }
portSfpTxOutPowerDb OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TX output optical power (dB)"
::= { sfpStatusEntry 12 }
portSfpRxOutPower OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RX output optical power (uW)"
::= { sfpStatusEntry 13 }
portSfpRxOutPowerDb OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"RX output optical power (dB)"
::= { sfpStatusEntry 14 }
-- Temperature/Humidity sensor group
SensorEntry ::= SEQUENCE {
sensorConnected INTEGER,
sensorTemperature INTEGER,
sensorHumidity INTEGER
}
sensorEntry OBJECT IDENTIFIER ::= { statusPSW 8}
sensorConnected OBJECT-TYPE
SYNTAX INTEGER { connected(1), disconnected(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Connection status of temperature/humidity sensor"
::= { sensorEntry 1 }
sensorTemperature OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Temperature value"
::= { sensorEntry 2 }
sensorHumidity OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Humidity value"
::= { sensorEntry 3 }
-- Parts for Teleport
-- Set/Config Groups
-- Traps group
updateFirmwareTLP NOTIFICATION-TYPE
STATUS current
DESCRIPTION
" This Notification indicates a firmwre updating"
::= { trapsTLP 1}
setToDefaultTLP NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Settings to default"
::= { trapsTLP 2}
backupSettingsTLP NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Make backup copy of settings in file"
::= { trapsTLP 3}
systemWarmStartTLP NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Start system after reboot"
::= { trapsTLP 4}
systemColdStartTLP NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Start system after power down (Cold start)"
::= { trapsTLP 5}
webInterfaceLoginOkTLP NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Successfully authentification on web-interface"
::= { trapsTLP 6}
webInterfaceLoginFailTLP NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Fail authentification on web-interface"
::= { trapsTLP 7}
emptyArpTableTLP NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Arp table is empty"
::= { trapsTLP 8}
input1isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 1 is changed"
::= { trapsTLP 9}
input2isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 2 is changed"
::= { trapsTLP 10}
input3isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 3 is changed"
::= { trapsTLP 11}
input4isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 4 is changed"
::= { trapsTLP 12}
input5isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 5 is changed"
::= { trapsTLP 13}
input6isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 6 is changed"
::= { trapsTLP 14}
input7isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 7 is changed"
::= { trapsTLP 15}
input8isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 8 is changed"
::= { trapsTLP 16}
input9isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Input 9 is changed"
::= { trapsTLP 17}
output1isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Output 1 is changed"
::= { trapsTLP 18}
output2isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Output 2 is changed"
::= { trapsTLP 19}
output3isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Output 3 is changed"
::= { trapsTLP 20}
output4isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Output 4 is changed"
::= { trapsTLP 21}
output5isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Output 5 is changed"
::= { trapsTLP 22}
output6isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Output 6 is changed"
::= { trapsTLP 23}
output7isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Output 7 is changed"
::= { trapsTLP 24}
output8isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Output 8 is changed"
::= { trapsTLP 25}
output9isChanged NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Output 9 is changed"
::= { trapsTLP 26}
device1connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 1 connection fail"
::= { trapsTLP 27}
device2connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 2 connection fail"
::= { trapsTLP 28}
device3connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 3 connection fail"
::= { trapsTLP 29}
device4connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 4 connection fail"
::= { trapsTLP 30}
device5connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 5 connection fail"
::= { trapsTLP 31}
device6connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 6 connection fail"
::= { trapsTLP 32}
device7connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 7 connection fail"
::= { trapsTLP 33}
device8connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 8 connection fail"
::= { trapsTLP 34}
device9connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 9 connection fail"
::= { trapsTLP 35}
device10connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 10 connection fail"
::= { trapsTLP 36}
device11connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 11 connection fail"
::= { trapsTLP 37}
device12connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 12 connection fail"
::= { trapsTLP 38}
device13connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 13 connection fail"
::= { trapsTLP 39}
device14connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 14 connection fail"
::= { trapsTLP 40}
device15connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 15 connection fail"
::= { trapsTLP 41}
device16connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 16 connection fail"
::= { trapsTLP 42}
device17connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 17 connection fail"
::= { trapsTLP 43}
device18connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 18 connection fail"
::= { trapsTLP 44}
device19connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 19 connection fail"
::= { trapsTLP 45}
device20connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 20 connection fail"
::= { trapsTLP 46}
device21connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 21 connection fail"
::= { trapsTLP 47}
device22connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 22 connection fail"
::= { trapsTLP 48}
device23connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 23 connection fail"
::= { trapsTLP 49}
device24connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 24 connection fail"
::= { trapsTLP 50}
device25connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 25 connection fail"
::= { trapsTLP 51}
device26connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 26 connection fail"
::= { trapsTLP 52}
device27connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 27 connection fail"
::= { trapsTLP 53}
device28connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 28 connection fail"
::= { trapsTLP 54}
device29connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 29 connection fail"
::= { trapsTLP 55}
device30connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 30 connection fail"
::= { trapsTLP 56}
device31connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 31 connection fail"
::= { trapsTLP 57}
device32connFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device 32 connection fail"
::= { trapsTLP 58}
-- Status/Config group
-- Inputs status group
inputTeleport OBJECT IDENTIFIER ::= { teleport 2}
inputStatusTableTLP OBJECT-TYPE
SYNTAX SEQUENCE OF InputStatusEntryTLP
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { inputTeleport 1 }
inputStatusEntryTLP OBJECT-TYPE
SYNTAX InputStatusEntryTLP
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) ."
INDEX { inputIndexTLP }
::= { inputStatusTableTLP 1 }
InputStatusEntryTLP ::= SEQUENCE {
inputIndexTLP INTEGER,
inputStateTLP INTEGER
}
inputIndexTLP OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input Number"
::= { inputStatusEntryTLP 1 }
inputStateTLP OBJECT-TYPE
SYNTAX INTEGER{ open(1), short(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input State"
::= { inputStatusEntryTLP 2 }
-- Output Status/Config Group
outputTeleport OBJECT IDENTIFIER ::= { teleport 3}
outputTeleportTable OBJECT-TYPE
SYNTAX SEQUENCE OF OutputTeleportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { outputTeleport 1 }
outputTeleportEntry OBJECT-TYPE
SYNTAX OutputTeleportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry (conceptual row) in the outputTeleportTable."
INDEX { outIndex }
::= { outputTeleportTable 1 }
OutputTeleportEntry ::= SEQUENCE {
outIndex INTEGER,
outState INTEGER
}
outIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Index of Output"
::= { outputTeleportEntry 1 }
outState OBJECT-TYPE
SYNTAX INTEGER { open(1), short(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"State of Output"
::= { outputTeleportEntry 2 }
-- Firmware status group
fwStatusTLP OBJECT IDENTIFIER ::= { teleport 4}
fwVersionTLP OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Firmware version"
::= { fwStatusTLP 1 }
END