-- smartoptics SiteLight Optical MIB
--
-- Jan 2002, Omri Viner
--
-- Copyright (c) 1999-2002 by SmartOptics AS
-- All rights reserved.
-- *****************************************************************
SL-OPT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE, IpAddress FROM SNMPv2-SMI
DisplayString, TruthValue,
TimeStamp, RowStatus FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF
InterfaceIndex FROM IF-MIB
PerfCurrentCount, PerfIntervalCount,
PerfTotalCount FROM PerfHist-TC-MIB
sitelight FROM SL-NE-MIB;
slOpt MODULE-IDENTITY
LAST-UPDATED "0201140000Z"
ORGANIZATION "SmartOptics AS"
CONTACT-INFO
"E-mail: d.lutz@smartoptics.com"
DESCRIPTION
"This MIB module describes the optical connections."
::= { sitelight 11 }
--
-- The Optical MIB consists of the following groups:
-- Dynamic Optical Connection Table for 2.5Gb transponder
-- Static Optical Connection Table for 10Gb transponder
-- Optical Last Change
-- Optical Traps
--
slOptConn OBJECT IDENTIFIER ::= { slOpt 1 }
-- slOptAps OBJECT IDENTIFIER ::= { slOpt 2 }
slOptLastChange OBJECT IDENTIFIER ::= { slOpt 6 }
slOptTraps OBJECT IDENTIFIER ::= { slOpt 7 }
--
-- The dynamic Transponding Connection Table
-- This table defines the connections between the Transponding modules
--
optXpdConnConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptXpdConnConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The dynamic Transponding table. The table contains for each
transponding connection two entries, one for each direction.
The index to the table is the ifIndex of both interfaces
because in the case of one of the APS configuration we define
a one-to-many connection.
The ifType valued used for the index is: 196."
::= { slOptConn 1 }
optXpdConnConfigEntry OBJECT-TYPE
SYNTAX OptXpdConnConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Transponding table."
INDEX { optXpdConnConfigIngressIf,
optXpdConnConfigEgressIf }
::= { optXpdConnConfigTable 1 }
OptXpdConnConfigEntry ::=
SEQUENCE {
optXpdConnConfigIngressIf InterfaceIndex,
optXpdConnConfigEgressIf InterfaceIndex,
optXpdConnConfigRateControlAdmin INTEGER,
optXpdConnConfigRateControlOper INTEGER,
optXpdConnConfigRowStatus RowStatus,
optXpdConnConfigLosPropagation TruthValue,
optXpdConnSonetRate TruthValue
}
optXpdConnConfigIngressIf OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ingress transponding interface."
::= { optXpdConnConfigEntry 1 }
optXpdConnConfigEgressIf OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The egress transponding interface."
::= { optXpdConnConfigEntry 2 }
optXpdConnConfigRateControlAdmin OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable ask the rate of the traffic used
by this interface. The value should be specified in Kbps
units.
The value of the optXpdConnConfigRateControlAdmin variable
should contain two information elements:
1. The retimer bit-rate.
2. The source of the rate (enum or explicit).
The second information element shall be taken from the right-most
bit of the object value. While the bit-rate will be represented by the
rest of the bits.
For example if the user configured an explicit bit rate R,
the value of the object will be 2xR.
If the user configured the same value by ENUM selection,
the object value shall be 2xR + 1.
This means that the MCC should send the service card the object
value shifted >> 1 (devide by 2).
The value 0 is used for rate control Bypass."
::= { optXpdConnConfigEntry 3 }
optXpdConnConfigRateControlOper OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable tells the rate of the traffic used
by this interface.
The value should be specified in Kbps.
The value is translate by the agent to the rate supported
by the hardware device units.
The value 0 is returned for rate control Bypass."
::= { optXpdConnConfigEntry 4 }
optXpdConnConfigRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create and delete rows in
the table."
::= { optXpdConnConfigEntry 5 }
optXpdConnConfigLosPropagation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to detrmine if the LOS propagation should be active."
::= { optXpdConnConfigEntry 6 }
optXpdConnSonetRate OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"In the case of implicit SONET rate, this variable should be TRUE.
If the case of explicit SONET rate, the user may select TRUE or FALSE.
In this case the default value is FALSE."
::= { optXpdConnConfigEntry 7 }
--
-- The static 10Gb Transponding Connection Table
-- This table defines the parameters for the
-- implicit transponding connection fo the 10G
--
optXpd10ConnConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF OptXpd10ConnConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The static 10Gb Transponding table. The table contains for each
transponding connection two entries, one for each direction.
The index to the table is the ifIndex the upper interface (port# 1).
The ifType valued used for the index is: 196."
::= { slOptConn 2 }
optXpd10ConnConfigEntry OBJECT-TYPE
SYNTAX OptXpd10ConnConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the 10Gb Transponding table."
INDEX { optXpd10ConnConfigIngressIf }
::= { optXpd10ConnConfigTable 1 }
OptXpd10ConnConfigEntry ::=
SEQUENCE {
optXpd10ConnConfigIngressIf InterfaceIndex,
optXpd10ConnConfigEgressIf InterfaceIndex,
optXpd10ConnConfigRateControlOper INTEGER,
optXpd10ConnConfigLosPropagation TruthValue
}
optXpd10ConnConfigIngressIf OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ingress transponding interface."
::= { optXpd10ConnConfigEntry 1 }
optXpd10ConnConfigEgressIf OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The egress transponding interface."
::= { optXpd10ConnConfigEntry 2 }
optXpd10ConnConfigRateControlOper OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable tells the rate of the traffic used
by this interface.
The value should be specified in Kbps.
The value is translate by the agent to the rate supported
by the hardware device units."
::= { optXpd10ConnConfigEntry 3 }
optXpd10ConnConfigLosPropagation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to detrmine if the LOS propagation should be active."
::= { optXpd10ConnConfigEntry 4 }
--
-- The last change objects
--
optXpdConnConfigLastChange OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of MIB II's sysUpTime object at the
time the optXpdConnConfigTable was last changed."
::= { slOptLastChange 1 }
--
-- The traps
--
optXpdConnConfigTableChange NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"A optXpdConnConfigTableChange trap is sent when the
content of the xpdConnConfigTable is changed."
::= { slOptTraps 1 }
END