-- ***************************************************************** -- smartoptics SiteLight Optical MIB -- -- Jan 2002, Omri Viner -- -- Copyright (c) 1999-2002 by SmartOptics AS -- All rights reserved. -- ***************************************************************** SL-OPT-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, IpAddress FROM SNMPv2-SMI DisplayString, TruthValue, TimeStamp, RowStatus FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF InterfaceIndex FROM IF-MIB PerfCurrentCount, PerfIntervalCount, PerfTotalCount FROM PerfHist-TC-MIB sitelight FROM SL-NE-MIB; slOpt MODULE-IDENTITY LAST-UPDATED "0201140000Z" ORGANIZATION "SmartOptics AS" CONTACT-INFO "E-mail: d.lutz@smartoptics.com" DESCRIPTION "This MIB module describes the optical connections." ::= { sitelight 11 } -- -- The Optical MIB consists of the following groups: -- Dynamic Optical Connection Table for 2.5Gb transponder -- Static Optical Connection Table for 10Gb transponder -- Optical Last Change -- Optical Traps -- slOptConn OBJECT IDENTIFIER ::= { slOpt 1 } -- slOptAps OBJECT IDENTIFIER ::= { slOpt 2 } slOptLastChange OBJECT IDENTIFIER ::= { slOpt 6 } slOptTraps OBJECT IDENTIFIER ::= { slOpt 7 } -- -- The dynamic Transponding Connection Table -- This table defines the connections between the Transponding modules -- optXpdConnConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF OptXpdConnConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The dynamic Transponding table. The table contains for each transponding connection two entries, one for each direction. The index to the table is the ifIndex of both interfaces because in the case of one of the APS configuration we define a one-to-many connection. The ifType valued used for the index is: 196." ::= { slOptConn 1 } optXpdConnConfigEntry OBJECT-TYPE SYNTAX OptXpdConnConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the Transponding table." INDEX { optXpdConnConfigIngressIf, optXpdConnConfigEgressIf } ::= { optXpdConnConfigTable 1 } OptXpdConnConfigEntry ::= SEQUENCE { optXpdConnConfigIngressIf InterfaceIndex, optXpdConnConfigEgressIf InterfaceIndex, optXpdConnConfigRateControlAdmin INTEGER, optXpdConnConfigRateControlOper INTEGER, optXpdConnConfigRowStatus RowStatus, optXpdConnConfigLosPropagation TruthValue, optXpdConnSonetRate TruthValue } optXpdConnConfigIngressIf OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The ingress transponding interface." ::= { optXpdConnConfigEntry 1 } optXpdConnConfigEgressIf OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The egress transponding interface." ::= { optXpdConnConfigEntry 2 } optXpdConnConfigRateControlAdmin OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-create STATUS current DESCRIPTION "This variable ask the rate of the traffic used by this interface. The value should be specified in Kbps units. The value of the optXpdConnConfigRateControlAdmin variable should contain two information elements: 1. The retimer bit-rate. 2. The source of the rate (enum or explicit). The second information element shall be taken from the right-most bit of the object value. While the bit-rate will be represented by the rest of the bits. For example if the user configured an explicit bit rate R, the value of the object will be 2xR. If the user configured the same value by ENUM selection, the object value shall be 2xR + 1. This means that the MCC should send the service card the object value shifted >> 1 (devide by 2). The value 0 is used for rate control Bypass." ::= { optXpdConnConfigEntry 3 } optXpdConnConfigRateControlOper OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This variable tells the rate of the traffic used by this interface. The value should be specified in Kbps. The value is translate by the agent to the rate supported by the hardware device units. The value 0 is returned for rate control Bypass." ::= { optXpdConnConfigEntry 4 } optXpdConnConfigRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create and delete rows in the table." ::= { optXpdConnConfigEntry 5 } optXpdConnConfigLosPropagation OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to detrmine if the LOS propagation should be active." ::= { optXpdConnConfigEntry 6 } optXpdConnSonetRate OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "In the case of implicit SONET rate, this variable should be TRUE. If the case of explicit SONET rate, the user may select TRUE or FALSE. In this case the default value is FALSE." ::= { optXpdConnConfigEntry 7 } -- -- The static 10Gb Transponding Connection Table -- This table defines the parameters for the -- implicit transponding connection fo the 10G -- optXpd10ConnConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF OptXpd10ConnConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The static 10Gb Transponding table. The table contains for each transponding connection two entries, one for each direction. The index to the table is the ifIndex the upper interface (port# 1). The ifType valued used for the index is: 196." ::= { slOptConn 2 } optXpd10ConnConfigEntry OBJECT-TYPE SYNTAX OptXpd10ConnConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the 10Gb Transponding table." INDEX { optXpd10ConnConfigIngressIf } ::= { optXpd10ConnConfigTable 1 } OptXpd10ConnConfigEntry ::= SEQUENCE { optXpd10ConnConfigIngressIf InterfaceIndex, optXpd10ConnConfigEgressIf InterfaceIndex, optXpd10ConnConfigRateControlOper INTEGER, optXpd10ConnConfigLosPropagation TruthValue } optXpd10ConnConfigIngressIf OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The ingress transponding interface." ::= { optXpd10ConnConfigEntry 1 } optXpd10ConnConfigEgressIf OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "The egress transponding interface." ::= { optXpd10ConnConfigEntry 2 } optXpd10ConnConfigRateControlOper OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "This variable tells the rate of the traffic used by this interface. The value should be specified in Kbps. The value is translate by the agent to the rate supported by the hardware device units." ::= { optXpd10ConnConfigEntry 3 } optXpd10ConnConfigLosPropagation OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to detrmine if the LOS propagation should be active." ::= { optXpd10ConnConfigEntry 4 } -- -- The last change objects -- optXpdConnConfigLastChange OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of MIB II's sysUpTime object at the time the optXpdConnConfigTable was last changed." ::= { slOptLastChange 1 } -- -- The traps -- optXpdConnConfigTableChange NOTIFICATION-TYPE STATUS current DESCRIPTION "A optXpdConnConfigTableChange trap is sent when the content of the xpdConnConfigTable is changed." ::= { slOptTraps 1 } END