Observium_CE/mibs/scte/SCTE-HMS-TIB-MIB

178 lines
5.3 KiB
Plaintext

-- ****************************************************************************
-- *
-- * Module Name: HMS050R5.MIB (SCTE 38-7)
-- *
-- * SCTE Status: ADOPTED JANUARY 11, 2002
-- *
-- * This MIB contains information about the communications state of
-- * devices connected to the transponder, as well as indicating what
-- * device-specific MIB each device supports. These devices are typically
-- * connected to the transponder via a serial communications link (bus).
-- *
-- ****************************************************************************
SCTE-HMS-TIB-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
transponderInterfaceBusIdent
FROM SCTE-HMS-ROOTS
;
tibAttachedDevices OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bit Map that indicates addresses of attached devices. Bit set means a device using that address
is attached to NE.
Bits Addresses
0 Not used
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 28
29 29
30 30
31 31
"
::= { transponderInterfaceBusIdent 1 }
tibCommStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bit Map that indicates attached devices that are not communicating. Bit set means a device using that address
is not communicating. This only applies to addresses whose bit is set in tibAttachedDevices.
Bits Addresses
0 Not used
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
15 15
16 16
17 17
18 18
19 19
20 20
21 21
22 22
23 23
24 24
25 25
26 26
27 27
28 28
29 29
30 30
31 31
"
::= { transponderInterfaceBusIdent 2 }
tibDevicesAddressedTable OBJECT-TYPE
SYNTAX SEQUENCE OF TibDevicesAddressedEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table containing identity of devices addressed by this NE.
This table should contain entries ONLY for devices that are physically
connected to the NE. If a device is not connected, no entry should be
created in the table for that address/index."
::= { transponderInterfaceBusIdent 3 }
tibDevicesAddressedEntry OBJECT-TYPE
SYNTAX TibDevicesAddressedEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry containing information about individual devices"
INDEX { tibDeviceAddress }
::= { tibDevicesAddressedTable 1 }
TibDevicesAddressedEntry ::=
SEQUENCE
{
tibDeviceAddress
INTEGER,
tibDeviceIdentity
OBJECT IDENTIFIER,
tibControlMode
INTEGER
}
tibDeviceAddress OBJECT-TYPE
SYNTAX INTEGER ( 1..31 )
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index into tibDevicesAddressedTable."
::= { tibDevicesAddressedEntry 1 }
tibDeviceIdentity OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Device identification. root OID for MIB that this device supports.
For Power Supply use psIdent from SCTE-HMS-ROOTS (1.3.6.1.4.1.5591.1.4)
For Fiber Node use fnIdent from SCTE-HMS-ROOTS (1.3.6.1.4.1.5591.1.5)
For Generator use genIdent from SCTE-HMS-ROOTS (1.3.6.1.4.1.5591.1.6)"
::= { tibDevicesAddressedEntry 2 }
tibControlMode OBJECT-TYPE
SYNTAX INTEGER { remote(1), local(2), notCommunicating(3) }
ACCESS read-only
STATUS optional
DESCRIPTION
"Control mode for this device
1 = Remote device will respond to commands from master NE
2 = Local device is under local control and will not respond
to commands from master NE
3 = This device is not responding.
This item requires entries in the discrete property table"
::= { tibDevicesAddressedEntry 3 }
END