-- **************************************************************************** -- * -- * Module Name: HMS050R5.MIB (SCTE 38-7) -- * -- * SCTE Status: ADOPTED JANUARY 11, 2002 -- * -- * This MIB contains information about the communications state of -- * devices connected to the transponder, as well as indicating what -- * device-specific MIB each device supports. These devices are typically -- * connected to the transponder via a serial communications link (bus). -- * -- **************************************************************************** SCTE-HMS-TIB-MIB DEFINITIONS ::= BEGIN IMPORTS OBJECT-TYPE FROM RFC-1212 transponderInterfaceBusIdent FROM SCTE-HMS-ROOTS ; tibAttachedDevices OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Bit Map that indicates addresses of attached devices. Bit set means a device using that address is attached to NE. Bits Addresses 0 Not used 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24 25 25 26 26 27 27 28 28 29 29 30 30 31 31 " ::= { transponderInterfaceBusIdent 1 } tibCommStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Bit Map that indicates attached devices that are not communicating. Bit set means a device using that address is not communicating. This only applies to addresses whose bit is set in tibAttachedDevices. Bits Addresses 0 Not used 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24 25 25 26 26 27 27 28 28 29 29 30 30 31 31 " ::= { transponderInterfaceBusIdent 2 } tibDevicesAddressedTable OBJECT-TYPE SYNTAX SEQUENCE OF TibDevicesAddressedEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table containing identity of devices addressed by this NE. This table should contain entries ONLY for devices that are physically connected to the NE. If a device is not connected, no entry should be created in the table for that address/index." ::= { transponderInterfaceBusIdent 3 } tibDevicesAddressedEntry OBJECT-TYPE SYNTAX TibDevicesAddressedEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entry containing information about individual devices" INDEX { tibDeviceAddress } ::= { tibDevicesAddressedTable 1 } TibDevicesAddressedEntry ::= SEQUENCE { tibDeviceAddress INTEGER, tibDeviceIdentity OBJECT IDENTIFIER, tibControlMode INTEGER } tibDeviceAddress OBJECT-TYPE SYNTAX INTEGER ( 1..31 ) ACCESS read-only STATUS mandatory DESCRIPTION "Index into tibDevicesAddressedTable." ::= { tibDevicesAddressedEntry 1 } tibDeviceIdentity OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Device identification. root OID for MIB that this device supports. For Power Supply use psIdent from SCTE-HMS-ROOTS (1.3.6.1.4.1.5591.1.4) For Fiber Node use fnIdent from SCTE-HMS-ROOTS (1.3.6.1.4.1.5591.1.5) For Generator use genIdent from SCTE-HMS-ROOTS (1.3.6.1.4.1.5591.1.6)" ::= { tibDevicesAddressedEntry 2 } tibControlMode OBJECT-TYPE SYNTAX INTEGER { remote(1), local(2), notCommunicating(3) } ACCESS read-only STATUS optional DESCRIPTION "Control mode for this device 1 = Remote device will respond to commands from master NE 2 = Local device is under local control and will not respond to commands from master NE 3 = This device is not responding. This item requires entries in the discrete property table" ::= { tibDevicesAddressedEntry 3 } END