-- Module Name: HMS116R7.MIB (SCTE 84-2)
SCTE-HMS-HE-POWER-SUPPLY-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, Unsigned32
FROM SNMPv2-SMI
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
DisplayString
FROM SNMPv2-TC
hePowerSupply, HeTenthVolt, HeHundredthWatts,
HeMilliAmp
FROM SCTE-HMS-HEADENDIDENT-MIB
entPhysicalIndex
FROM ENTITY-MIB;
hePowerSupplyMIB MODULE-IDENTITY
LAST-UPDATED "200403250410Z"
ORGANIZATION
"SCTE HMS Working Group"
CONTACT-INFO
"SCTE HMS Subcommittee, Chairman
mail to: standards@scte.org"
DESCRIPTION
"The MIB module is for representing a power supply present in the
headend (or indoor) and supported by a SNMP agent."
::= { hePowerSupply 1 }
hePsMIBObjects OBJECT IDENTIFIER ::= { hePowerSupplyMIB 1 }
-- Conformance Information
hePsMIBConformance OBJECT IDENTIFIER ::= { hePowerSupplyMIB 2 }
hePsMIBCompliances OBJECT IDENTIFIER ::= { hePsMIBConformance 1 }
hePsMIBGroups OBJECT IDENTIFIER ::= { hePsMIBConformance 2 }
-- The Power Supply Unit Table
hePsUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF HePsUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about headend (or indoor plant)
power supplies. These power supplies could be, for example,
plug-in modules for a chassis."
::= { hePsMIBObjects 1 }
hePsUnitEntry OBJECT-TYPE
SYNTAX HePsUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about each Power Supply in the subsystem. Each Power Supply
unit will have an entry in the Entity MIB supported for this agent."
INDEX { entPhysicalIndex }
::= { hePsUnitTable 1 }
HePsUnitEntry ::= SEQUENCE {
hePsUnitCurrentIN
HeMilliAmp,
hePsUnitPowerIN
HeHundredthWatts,
hePsUnitDescription
DisplayString,
hePsUnitVoltageIN
HeTenthVolt
}
hePsUnitCurrentIN OBJECT-TYPE
SYNTAX HeMilliAmp
UNITS "milliamperes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Scaled representation of the input current (AC or DC) for
this power supply. This is an RMS value for AC currents.
This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { hePsUnitEntry 1 }
hePsUnitPowerIN OBJECT-TYPE
SYNTAX HeHundredthWatts
UNITS "hundredths of a watt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Scaled representation of the input power (AC or DC) for
this power supply. This is an RMS value for AC powers.
This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { hePsUnitEntry 2 }
hePsUnitDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string will describe the model type of the Power Supply.
Examples are AC+110, AC+220, DC-48, DC+48. This model type should
match the entry in the Entity mib for this object."
::= { hePsUnitEntry 3 }
hePsUnitVoltageIN OBJECT-TYPE
SYNTAX HeTenthVolt
UNITS "tenths of a volt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Scaled representation of the input voltage (AC or DC) for
this power supply. This is an RMS value for AC voltages.
This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { hePsUnitEntry 4 }
-- The Power Supply Output Table
hePsOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF HePsOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of monitorable parameter entries for power supply
outputs."
::= { hePsMIBObjects 2 }
hePsOutputEntry OBJECT-TYPE
SYNTAX HePsOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable to
a particular power supplies outputs."
INDEX { entPhysicalIndex,
hePsOutputIndex }
::= { hePsOutputTable 1 }
HePsOutputEntry ::= SEQUENCE {
hePsOutputIndex
Unsigned32,
hePsOutputVoltage
HeTenthVolt,
hePsOutputCurrent
HeMilliAmp,
hePsOutputPower
HeHundredthWatts
}
hePsOutputIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary value which uniquely identifies each entry."
::= { hePsOutputEntry 1 }
hePsOutputVoltage OBJECT-TYPE
SYNTAX HeTenthVolt
UNITS "tenths of a volt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Scaled representation of the output voltage for this power supply output.
If a single PHYSICAL power supply provides multiple voltages, each voltage
shall have its own entry in this table.
This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { hePsOutputEntry 2 }
hePsOutputCurrent OBJECT-TYPE
SYNTAX HeMilliAmp
UNITS "milliamperes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Scaled representation of the output current for this power supply output.
This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { hePsOutputEntry 3 }
hePsOutputPower OBJECT-TYPE
SYNTAX HeHundredthWatts
UNITS "hundredths of a watt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Scaled representation of the output power for this power supply output.
This object must provide for the alarm management capabilities
with a corresponding entry in the propertyTable of
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { hePsOutputEntry 4 }
-- Compliance statements
hePsCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The minimum compliance statement for indoor power supplies."
MODULE
MANDATORY-GROUPS { hePsOutputMandatoryGroup }
GROUP hePsUnitGroup
DESCRIPTION
"The hePsUnitGroup is unconditionally optional."
GROUP hePsOutputGroup
DESCRIPTION
"The hePsOutputGroup is unconditionally optional."
::= { hePsMIBCompliances 1 }
-- this module
hePsOutputMandatoryGroup OBJECT-GROUP
OBJECTS { hePsOutputVoltage }
STATUS current
DESCRIPTION
"A mandatory collection of objects that provide information
applicable to a particular power supply's output
parameters."
::= { hePsMIBGroups 1 }
hePsUnitGroup OBJECT-GROUP
OBJECTS { hePsUnitVoltageIN,
hePsUnitCurrentIN,
hePsUnitPowerIN,
hePsUnitDescription }
STATUS current
DESCRIPTION
"A collection of objects that provide information applicable to a
particular power supply's input parameters."
::= { hePsMIBGroups 2 }
hePsOutputGroup OBJECT-GROUP
OBJECTS { hePsOutputCurrent,
hePsOutputPower }
STATUS current
DESCRIPTION
"A collection of objects that provide information applicable to a
particular power supply's output parameters."
::= { hePsMIBGroups 3 }
END