-- Module Name: HMS116R7.MIB (SCTE 84-2)
|
|
|
|
SCTE-HMS-HE-POWER-SUPPLY-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
OBJECT-GROUP, MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
hePowerSupply, HeTenthVolt, HeHundredthWatts,
|
|
HeMilliAmp
|
|
FROM SCTE-HMS-HEADENDIDENT-MIB
|
|
entPhysicalIndex
|
|
FROM ENTITY-MIB;
|
|
|
|
hePowerSupplyMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200403250410Z"
|
|
ORGANIZATION
|
|
"SCTE HMS Working Group"
|
|
CONTACT-INFO
|
|
"SCTE HMS Subcommittee, Chairman
|
|
mail to: standards@scte.org"
|
|
DESCRIPTION
|
|
"The MIB module is for representing a power supply present in the
|
|
headend (or indoor) and supported by a SNMP agent."
|
|
::= { hePowerSupply 1 }
|
|
|
|
hePsMIBObjects OBJECT IDENTIFIER ::= { hePowerSupplyMIB 1 }
|
|
|
|
-- Conformance Information
|
|
|
|
hePsMIBConformance OBJECT IDENTIFIER ::= { hePowerSupplyMIB 2 }
|
|
hePsMIBCompliances OBJECT IDENTIFIER ::= { hePsMIBConformance 1 }
|
|
hePsMIBGroups OBJECT IDENTIFIER ::= { hePsMIBConformance 2 }
|
|
|
|
-- The Power Supply Unit Table
|
|
|
|
hePsUnitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HePsUnitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing information about headend (or indoor plant)
|
|
power supplies. These power supplies could be, for example,
|
|
plug-in modules for a chassis."
|
|
::= { hePsMIBObjects 1 }
|
|
|
|
hePsUnitEntry OBJECT-TYPE
|
|
SYNTAX HePsUnitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about each Power Supply in the subsystem. Each Power Supply
|
|
unit will have an entry in the Entity MIB supported for this agent."
|
|
INDEX { entPhysicalIndex }
|
|
::= { hePsUnitTable 1 }
|
|
|
|
HePsUnitEntry ::= SEQUENCE {
|
|
hePsUnitCurrentIN
|
|
HeMilliAmp,
|
|
hePsUnitPowerIN
|
|
HeHundredthWatts,
|
|
hePsUnitDescription
|
|
DisplayString,
|
|
hePsUnitVoltageIN
|
|
HeTenthVolt
|
|
}
|
|
|
|
hePsUnitCurrentIN OBJECT-TYPE
|
|
SYNTAX HeMilliAmp
|
|
UNITS "milliamperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Scaled representation of the input current (AC or DC) for
|
|
this power supply. This is an RMS value for AC currents.
|
|
|
|
This object must provide for the alarm management capabilities
|
|
with a corresponding entry in the propertyTable of
|
|
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
An alarm shall be recorded as an entry in the currentAlarmTable
|
|
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
A log record shall be added as an entry in the heCommonLogTable.
|
|
|
|
An heCommonAlarmEvent notification shall be sent."
|
|
::= { hePsUnitEntry 1 }
|
|
|
|
hePsUnitPowerIN OBJECT-TYPE
|
|
SYNTAX HeHundredthWatts
|
|
UNITS "hundredths of a watt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Scaled representation of the input power (AC or DC) for
|
|
this power supply. This is an RMS value for AC powers.
|
|
|
|
This object must provide for the alarm management capabilities
|
|
with a corresponding entry in the propertyTable of
|
|
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
An alarm shall be recorded as an entry in the currentAlarmTable
|
|
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
A log record shall be added as an entry in the heCommonLogTable.
|
|
|
|
An heCommonAlarmEvent notification shall be sent."
|
|
::= { hePsUnitEntry 2 }
|
|
|
|
hePsUnitDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This string will describe the model type of the Power Supply.
|
|
Examples are AC+110, AC+220, DC-48, DC+48. This model type should
|
|
match the entry in the Entity mib for this object."
|
|
::= { hePsUnitEntry 3 }
|
|
|
|
hePsUnitVoltageIN OBJECT-TYPE
|
|
SYNTAX HeTenthVolt
|
|
UNITS "tenths of a volt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Scaled representation of the input voltage (AC or DC) for
|
|
this power supply. This is an RMS value for AC voltages.
|
|
|
|
This object must provide for the alarm management capabilities
|
|
with a corresponding entry in the propertyTable of
|
|
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
An alarm shall be recorded as an entry in the currentAlarmTable
|
|
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
A log record shall be added as an entry in the heCommonLogTable.
|
|
|
|
An heCommonAlarmEvent notification shall be sent."
|
|
::= { hePsUnitEntry 4 }
|
|
|
|
-- The Power Supply Output Table
|
|
|
|
hePsOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HePsOutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of monitorable parameter entries for power supply
|
|
outputs."
|
|
::= { hePsMIBObjects 2 }
|
|
|
|
hePsOutputEntry OBJECT-TYPE
|
|
SYNTAX HePsOutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to
|
|
a particular power supplies outputs."
|
|
INDEX { entPhysicalIndex,
|
|
hePsOutputIndex }
|
|
::= { hePsOutputTable 1 }
|
|
|
|
HePsOutputEntry ::= SEQUENCE {
|
|
hePsOutputIndex
|
|
Unsigned32,
|
|
hePsOutputVoltage
|
|
HeTenthVolt,
|
|
hePsOutputCurrent
|
|
HeMilliAmp,
|
|
hePsOutputPower
|
|
HeHundredthWatts
|
|
}
|
|
|
|
hePsOutputIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An arbitrary value which uniquely identifies each entry."
|
|
::= { hePsOutputEntry 1 }
|
|
|
|
hePsOutputVoltage OBJECT-TYPE
|
|
SYNTAX HeTenthVolt
|
|
UNITS "tenths of a volt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Scaled representation of the output voltage for this power supply output.
|
|
|
|
If a single PHYSICAL power supply provides multiple voltages, each voltage
|
|
shall have its own entry in this table.
|
|
|
|
This object must provide for the alarm management capabilities
|
|
with a corresponding entry in the propertyTable of
|
|
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
An alarm shall be recorded as an entry in the currentAlarmTable
|
|
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
A log record shall be added as an entry in the heCommonLogTable.
|
|
|
|
An heCommonAlarmEvent notification shall be sent."
|
|
::= { hePsOutputEntry 2 }
|
|
|
|
hePsOutputCurrent OBJECT-TYPE
|
|
SYNTAX HeMilliAmp
|
|
UNITS "milliamperes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Scaled representation of the output current for this power supply output.
|
|
|
|
This object must provide for the alarm management capabilities
|
|
with a corresponding entry in the propertyTable of
|
|
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
An alarm shall be recorded as an entry in the currentAlarmTable
|
|
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
A log record shall be added as an entry in the heCommonLogTable.
|
|
|
|
An heCommonAlarmEvent notification shall be sent."
|
|
::= { hePsOutputEntry 3 }
|
|
|
|
hePsOutputPower OBJECT-TYPE
|
|
SYNTAX HeHundredthWatts
|
|
UNITS "hundredths of a watt"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Scaled representation of the output power for this power supply output.
|
|
|
|
This object must provide for the alarm management capabilities
|
|
with a corresponding entry in the propertyTable of
|
|
SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
An alarm shall be recorded as an entry in the currentAlarmTable
|
|
of SCTE-HMS-PROPERTY-MIB (ANSI/SCTE 38-1).
|
|
|
|
A log record shall be added as an entry in the heCommonLogTable.
|
|
|
|
An heCommonAlarmEvent notification shall be sent."
|
|
::= { hePsOutputEntry 4 }
|
|
|
|
-- Compliance statements
|
|
|
|
hePsCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum compliance statement for indoor power supplies."
|
|
MODULE
|
|
MANDATORY-GROUPS { hePsOutputMandatoryGroup }
|
|
GROUP hePsUnitGroup
|
|
DESCRIPTION
|
|
"The hePsUnitGroup is unconditionally optional."
|
|
GROUP hePsOutputGroup
|
|
DESCRIPTION
|
|
"The hePsOutputGroup is unconditionally optional."
|
|
::= { hePsMIBCompliances 1 }
|
|
|
|
-- this module
|
|
|
|
hePsOutputMandatoryGroup OBJECT-GROUP
|
|
OBJECTS { hePsOutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A mandatory collection of objects that provide information
|
|
applicable to a particular power supply's output
|
|
parameters."
|
|
::= { hePsMIBGroups 1 }
|
|
|
|
hePsUnitGroup OBJECT-GROUP
|
|
OBJECTS { hePsUnitVoltageIN,
|
|
hePsUnitCurrentIN,
|
|
hePsUnitPowerIN,
|
|
hePsUnitDescription }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that provide information applicable to a
|
|
particular power supply's input parameters."
|
|
::= { hePsMIBGroups 2 }
|
|
|
|
hePsOutputGroup OBJECT-GROUP
|
|
OBJECTS { hePsOutputCurrent,
|
|
hePsOutputPower }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects that provide information applicable to a
|
|
particular power supply's output parameters."
|
|
::= { hePsMIBGroups 3 }
|
|
END
|