751 lines
27 KiB
Plaintext
751 lines
27 KiB
Plaintext
-- Module Name: HMS119R7.MIB (SCTE 85-4)
|
|
-- SCTE Status: Draft Revision 7
|
|
|
|
SCTE-HMS-HE-OPTICAL-SWITCH-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
OBJECT-TYPE, MODULE-IDENTITY, Unsigned32, Integer32
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
entPhysicalIndex
|
|
FROM ENTITY-MIB
|
|
HeFaultStatus,HeHundredthNanoMeter,
|
|
HeTenthdB, HeTenthdBm, HeOnOffControl
|
|
FROM SCTE-HMS-HEADENDIDENT-MIB
|
|
heOpticalSwitchGroup
|
|
FROM SCTE-HMS-HE-OPTICS-MIB;
|
|
|
|
|
|
heOpticalSwitchMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200309110000Z" -- Sep 11, 2003
|
|
ORGANIZATION "SCTE HMS Working Group"
|
|
CONTACT-INFO
|
|
"SCTE HMS Subcommittee, Chairman
|
|
mailto: standards@SCTE.org"
|
|
|
|
DESCRIPTION
|
|
" Change Log:
|
|
1. Added Unsigned32 and Integer32 to IMPORTS
|
|
2. Removed TEXTUAL-CONVENTION from IMPORTS
|
|
3. Corrected 4 digit date code defined in RFC2578
|
|
4. heOpSwitchWaitToRestoreTime is changed to Integer32
|
|
instead of INTEGER
|
|
5. Removed extra commas in heOpSwitchUnitMandatoryGroup,
|
|
heOpSwitchUnitGroup and heOpSwitchInputGroup
|
|
6. Changed OID of heOpSwitchMIBCompliances to 1 instead of 2
|
|
7. Changed the text description of SNMPv2 to SNMP for
|
|
heOpSwitchBasicCompliance MODULE-COMPLIANCE"
|
|
REVISION "200309110000Z"
|
|
|
|
DESCRIPTION
|
|
" Change Log:
|
|
1. Fixed all compile errors
|
|
2. Defined heOpSwitchInputIndex in the input entry sequence
|
|
3. Defined heOpSwitchOutputIndex in the Output entry sequence"
|
|
REVISION "200305290000Z"
|
|
|
|
|
|
DESCRIPTION
|
|
"The MIB module for the HMS HE Optical Switch module
|
|
entities.
|
|
|
|
This MIB module is for representing optical
|
|
switch equipment present in the headend (or indoor)
|
|
and is supported by a SNMP agent.
|
|
|
|
This MIB is limited in its scope and intended to
|
|
describe an A-B (2 input and 1 output) or a crossbar
|
|
optical switch. Up to 2 optical inputs and 2 outputs
|
|
are supported. Any devices with more than 2 optical
|
|
inputs or outputs shall be covered by another MIB.
|
|
|
|
This MIB does not intend to dictate all of the nuances
|
|
involved in changing control settings (automatic or
|
|
manual mode, changing switch controls in each possible
|
|
mode combination). The most common desired behaviors
|
|
are noted but specific switch operation and behavior
|
|
are left to the optical switch vendors.
|
|
|
|
Not all control enumerations must be supported. This
|
|
is noted in the variables that have optional
|
|
enumerations.
|
|
|
|
Refer to the associated notes for information on what
|
|
SNMP responses should be returned for unsupported
|
|
enumerations."
|
|
|
|
REVISION "200304250000Z" -- April 25, 2003
|
|
DESCRIPTION
|
|
"Change log:
|
|
1. Beautified MIB. Made sure all lines are 80 columns or
|
|
less.
|
|
2. Removed default enumeration from heOpSwitchControl
|
|
and heOpSwitchMode.
|
|
3. Corrected name of the heOpSwitchWaitToRestoreTime.
|
|
It was erroneously left as heOpSwitchHysteresisTime in
|
|
R3.
|
|
4. Removed instructions regarding the SET response for
|
|
heOpSwitchMode and heOpSwitchRevertEnable. The
|
|
information is not necessary since the variables could
|
|
be set as read-only.
|
|
5. Edited MIB description to make it more clear.
|
|
6. Adopted the standard HMS MIBlanguage to indicate
|
|
when a variable must have an entry in the discrete
|
|
properties.
|
|
7. Added comment header at top of file. SCTE revision is
|
|
set to one.
|
|
8. Added HeHundredthNanoMeter and HeOnOffControl to IMPORTS.
|
|
Removed HeTenthCentigrade from IMPORTS"
|
|
|
|
REVISION "200301210000Z" -- January 21, 2003
|
|
DESCRIPTION
|
|
"Change log:
|
|
1. Beautified MIB. Made sure all lines are 80 columns or
|
|
less.
|
|
2. Removed default enumeration from heOpSwitchControl
|
|
and heOpSwitchMode.
|
|
3. Corrected name of the heOpSwitchWaitToRestoreTime.
|
|
It was erroneously left as heOpSwitchHysteresisTime in
|
|
R3.
|
|
4. Removed instructions regarding the SET response for
|
|
heOpSwitchMode and heOpSwitchRevertEnable. The
|
|
information is not necessary since the variables could
|
|
be set as read-only.
|
|
5. Edited MIB description to make it more clear.
|
|
6. Adopted the standard HMS MIBlanguage to indicate
|
|
when a variable must have an entry in the discrete
|
|
properties.
|
|
7. Added comment header at top of file. SCTE revision is
|
|
set to one.
|
|
"
|
|
REVISION "200212040000Z" -- December 04, 2002
|
|
DESCRIPTION
|
|
"Change log:
|
|
As a result of discussions at the SCTE HMS Subcommittee
|
|
meeting held 10/10/2002
|
|
1. Reorganized optical switch objects into three tables:
|
|
heOpSwitchUnitTable,heOpSwitchInputTable and
|
|
heOpSwitchOutputTable.
|
|
2. Revised HMS119 to represent an optical AB switch or
|
|
crossbar switch with 1-2 inputs and 1-2 outputs. Switches
|
|
with more than two inputs or outputs must be covered by
|
|
another MIB. This was decided by the HMS Subcommittee
|
|
at the 10/10/2002 meeting as a way to manage the
|
|
complexity of the switch device.
|
|
3. Simplified the heOpSwitchControl variable. It was
|
|
broken up because the enumerations were becoming too
|
|
cumbersome for each possible switch setting. Removed
|
|
some enumerations and created heOpSwitchMode and
|
|
heOpRevertEnable to include those removed
|
|
enumerations/controls.
|
|
4. Added heOpSwitchFailoverStatus. Made it mandatory
|
|
to include a discrete property entry.
|
|
5. Made it mandatory to include a discrete property
|
|
entry if heOpSwitchBothInputStatus is supported.
|
|
6. Replaced the heOpSwitchSelectWavelength description
|
|
with the same description used in
|
|
the optical receiver MIB (SCTE-HMS-HE-OPTICAL-RECEIVER-MIB
|
|
HMS113).
|
|
7. Modified the heOpSwitchBasicCompliance mandatory
|
|
groups definition to include newly defined mandatory groups
|
|
associated with the added tables defined in change 1
|
|
above.
|
|
8. Added heOpSwitchUnitMandatoryGroup,
|
|
heOpSwitchInputMandatoryGroup and
|
|
heOpSwitchOutputMandatoryGroup to heOpSwitchMIBGroups.
|
|
9. Added heOpSwitchUnitGroup, heOpSwitchInputGroup and
|
|
heOpSwitchOutputGroup to heOpSwitchMIBGroups
|
|
10. Modified contact list (added Motorola editor of R3).
|
|
11. Removed heOpSwitchModuleTemp since it was redundant.
|
|
12. Removed ranges on HeTenthdBm type variables since the
|
|
definition already include ranges.
|
|
13. Modified the description of this MIB.
|
|
14. Expanded comments to describe how the optical switch
|
|
is modeled by the added tables.
|
|
|
|
This version obsoletes 'HMS119R2.mib'.
|
|
This version published as 'HMS119R3.mib'."
|
|
|
|
REVISION "200210060000Z" -- October 06, 2002
|
|
DESCRIPTION
|
|
"Change log:
|
|
1. Changed prefix of all variables to 'heOpSwitch'.
|
|
2. Introduced heOpSwitchMIBObjects branch.
|
|
3. Made all MIB objects grow off that branch.
|
|
4. Changed OID of heOpSwitchMIBConformance.
|
|
5. Changed index clause of heOpSwitchUnitEntry.
|
|
6. Changed syntax and description of
|
|
heOpSwitchBothInputStatus.
|
|
7. Beautified MIB.
|
|
|
|
This version obsoletes 'HMS119R1.mib'.
|
|
This version published as 'HMS119R2.mib'."
|
|
|
|
REVISION "200209250000Z"
|
|
DESCRIPTION
|
|
"Initial version of SCTE-HMS-HE-Optical-Switch-MIB.
|
|
This version is published as 'HMS119R1.mib'."
|
|
::= { heOpticalSwitchGroup 1 }
|
|
|
|
heOpSwitchMIBObjects OBJECT IDENTIFIER ::= { heOpticalSwitchMIB 1}
|
|
|
|
|
|
-- Every optical switch is modeled by the tables presented
|
|
-- in this MIB module. These tables extend the entPhysicalTable
|
|
-- according to RFC 2737. The extension index entPhysicalIndex uniquely
|
|
-- identifies the optical switch.
|
|
|
|
-- Every optical switch is also modeled by the following tables:
|
|
-- entPhysicalEntry - 1 row; (defined in document: RFC2737)
|
|
-- heCommonEntry - 1 row. (defined in document: HMS111)
|
|
|
|
-- Every optical switch module will have its alarms modeled by the table:
|
|
-- propertyEntry - x rows; (defined in document: HMS026)
|
|
-- (where x is the nos. of alarmable analog properties supported
|
|
-- by the optical switch)
|
|
|
|
-- discretePropertyEntry - y rows; (defined in document: HMS026)
|
|
-- (where y is the nos. of alarmable digital properties supported by
|
|
-- the optical switch)
|
|
|
|
-- Every optical switch module will have a list of currently active
|
|
-- alarms modeled by the table:
|
|
-- currentAlarmEntry - z rows; (defined in document: HMS026)
|
|
-- (where z is the nos. of current active alarms in the optical
|
|
-- switch)
|
|
|
|
-- Thus, an A-B optical switch (2 optical inputs and one optical output)
|
|
-- will be represented by one row in entPhysicalTable, one row in
|
|
-- heCommonTable, one row in heOpSwitchUnitTable, two rows in
|
|
-- heOpSwitchInputTable and one row in heOpSwitchOutputTable.
|
|
|
|
-- Additionally, a crossbar optical switch (2 inputs and 2 outputs)
|
|
-- will be represented by one row in entPhysicalTable, one row in
|
|
-- heCommonTable, one row in heOpSwitchUnitTable, two rows
|
|
-- in heOpSwitchInputTable and two rows in heOpSwitchOutputTable.
|
|
|
|
-- Correlation of outputs and inputs are indicated by the heOpSwitchState
|
|
-- variable. Correlation of physical inputs and outputs to
|
|
-- heOpSwitchInputTable and heOpSwitchOutputTables rows is indicated
|
|
-- by the heOpSwitchInputDescription and heOpSwitchOutputDescription
|
|
-- variables.
|
|
|
|
|
|
|
|
-- the Optical Switch Unit Table
|
|
heOpSwitchUnitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HeOpSwitchUnitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing information about Optical Switch used
|
|
in an indoor environment."
|
|
::= { heOpSwitchMIBObjects 1 }
|
|
|
|
heOpSwitchUnitEntry OBJECT-TYPE
|
|
SYNTAX HeOpSwitchUnitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of information about each optical switch."
|
|
INDEX { entPhysicalIndex }
|
|
::= { heOpSwitchUnitTable 1 }
|
|
|
|
HeOpSwitchUnitEntry ::= SEQUENCE {
|
|
heOpSwitchMode INTEGER,
|
|
heOpSwitchControl INTEGER,
|
|
heOpSwitchRevertEnable HeOnOffControl,
|
|
heOpSwitchState INTEGER,
|
|
heOpSwitchFailoverStatus HeFaultStatus,
|
|
heOpSwitchBothInputStatus HeFaultStatus,
|
|
heOpSwitchSelectWavelength HeHundredthNanoMeter,
|
|
heOpSwitchHysteresis HeTenthdB,
|
|
heOpSwitchWaitToRestoreTime Integer32
|
|
}
|
|
|
|
heOpSwitchMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
automatic(1),
|
|
manual(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls and/or reports the switching mode. If
|
|
automatic(1), the optical switch will evaluate the optical
|
|
input status and make the decision to affect the switch state.
|
|
If set to manual(2), the optical switch will not affect the
|
|
switch state itself."
|
|
|
|
::= { heOpSwitchUnitEntry 1 }
|
|
|
|
|
|
heOpSwitchControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pathA(1),
|
|
pathB(2),
|
|
cross(3),
|
|
bar(4),
|
|
bothA(5),
|
|
bothB(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the intended state of the Optical Switch. The effect
|
|
of this control will depend on the value of heOpSwitchMode.
|
|
If heOpSwitchMode is set to automatic, the value this
|
|
control is set to will be the preferred setting. If it is
|
|
set to manual, the switch will assume this setting. Actual
|
|
switch operation while changing switch control value(s)
|
|
is up to the equipment vendor. For example, if the switch
|
|
is in manual mode and the operator tries to connect the
|
|
output to an invalid input, the switch may or may
|
|
not change state.
|
|
|
|
Not all enumerations must be supported. For example, an
|
|
A-B optical switch may support only the pathA and pathB
|
|
enumerations while a cross-bar switch may support cross,
|
|
bar, bothA or bothB or only cross and bar but not pathA
|
|
and pathB enumerations. See the note below about the
|
|
expected SNMP response.
|
|
|
|
A value pathA(1) connects the switch output to side A
|
|
(first input) of the switch. This enumeration is intended
|
|
for use by an A-B switch.
|
|
|
|
A value pathB(2) connects the switch output to side B
|
|
(second input) of the switch. This enumeration is intended
|
|
for use by an A-B switch.
|
|
|
|
A value cross(3) connects the switch outputs to the inputs
|
|
as follows:
|
|
Side A (first or primary) output is connected to side B
|
|
(second or alternate) input.
|
|
Side B (second or alternate) output is connected to
|
|
side A (first or primary) input.
|
|
This enumeration is intended for use by a cross-bar switch.
|
|
A value bar(4) connects the switch outputs to the inputs as
|
|
follows:
|
|
Side A (first or primary) output is connected to side A
|
|
(first or primary) input.
|
|
Side B (second or alternate) output is connected to
|
|
side B (second or alternate) input.
|
|
This enumeration is intended for use by a cross-bar switch.
|
|
|
|
A value bothA(5) connects the switch outputs to the inputs as
|
|
follows:
|
|
Side A (first or primary) output is connected to side A
|
|
(first or primary) input.
|
|
Side B (second or alternate) output is connected to
|
|
side A (first or primary) input.
|
|
This enumeration is intended for use by a cross-bar switch.
|
|
|
|
A value bothB(6) connects the switch outputs to the inputs
|
|
as follows:
|
|
Side A (first or primary) output is connected to side B
|
|
(second or alternate) input.
|
|
Side B (second or alternate) output is connected to
|
|
side B (second or alternate) input.
|
|
This enumeration is intended for use by a cross-bar switch.
|
|
|
|
|
|
*** IMPORTANT ***
|
|
It is NOT required that an optical switch support all
|
|
enumerations. A SET request for an unsupported value shall
|
|
yield a badValue(3) error by an SNMPv1 agent or an
|
|
inconsistentValue(12) by an SNMPv2 agent."
|
|
::= { heOpSwitchUnitEntry 2 }
|
|
|
|
|
|
heOpSwitchRevertEnable OBJECT-TYPE
|
|
SYNTAX HeOnOffControl
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls the use of revertive switching.
|
|
|
|
If set to on, the switch will attempt to go back to the
|
|
preferred settings indicated by heOpSwitchControl if
|
|
heOpSwitchMode is set to automatic, and the input status
|
|
of the preferred input is normal. The switch will not
|
|
attempt to revert to the settings indicated by
|
|
heOpSwitchControl until heOpSwitchWaitToRestoreTime
|
|
(if supported) has expired since the preferred input was
|
|
restored to normal levels.
|
|
|
|
|
|
If set to off, the switch will not attempt to go back to
|
|
the preferred settings indicated by heOpSwitchControl if
|
|
heOpSwitchMode is set to automatic, and the input status
|
|
of the preferred input is normal.
|
|
"
|
|
|
|
::= { heOpSwitchUnitEntry 3 }
|
|
|
|
|
|
heOpSwitchState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pathA(1),
|
|
pathB(2),
|
|
cross(3),
|
|
bar(4),
|
|
bothA(5),
|
|
bothB(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reports the state of the Optical Switch. Not all enumerations
|
|
must be supported. For example, an A-B optical switch may
|
|
support only the pathA and pathB enumerations while a
|
|
cross-bar switch may support cross, bar, bothA or bothB or
|
|
only cross and bar but not pathA and pathB enumerations.
|
|
|
|
A value pathA(1) indicates that the switch output is being
|
|
fed by side A (first input) of the switch. This enumeration
|
|
is intended for use by an A-B switch.
|
|
|
|
A value pathB(2) indicates that the switch output is being
|
|
fed by side B (second input) of the switch. This enumeration
|
|
is intended for use by an A-B switch.
|
|
|
|
A value cross(3) indicates that the switch outputs are fed as
|
|
follows:
|
|
Side A (first or primary) output is connected to side B
|
|
(second or alternate) input.
|
|
Side B (second or alternate) output is connected to side A
|
|
(first or primary) input.
|
|
This enumeration is intended for use by a cross-bar switch.
|
|
|
|
A value bar(4) indicates that the switch outputs are fed as
|
|
follows:
|
|
Side A (first or primary) output is connected to side A
|
|
(first or primary) input.
|
|
Side B (second or alternate) output is connected to side B
|
|
(second or alternate) input.
|
|
This enumeration is intended for use by a cross-bar switch.
|
|
|
|
A value bothA(5) indicates that the switch outputs are fed as
|
|
follows:
|
|
Side A (first or primary) output is connected to side A
|
|
(first or primary) input.
|
|
Side B (second or alternate) output is connected to side A
|
|
(first or primary) input.
|
|
This enumeration is intended for use by a cross-bar switch.
|
|
|
|
A value bothB(6) indicates that the switch outputs are fed as
|
|
follows:
|
|
Side A (first or primary) output is connected to side B
|
|
(second or alternate) input.
|
|
Side B (second or alternate) output is connected to side B
|
|
(second or alternate) input.
|
|
This enumeration is intended for use by a cross-bar switch."
|
|
|
|
::= { heOpSwitchUnitEntry 4 }
|
|
|
|
|
|
heOpSwitchFailoverStatus OBJECT-TYPE
|
|
SYNTAX HeFaultStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integral status of both inputs.
|
|
|
|
A value is fault(2), if current switch state heOpSwitchState
|
|
is different than the preferred setting heOpSwitchControl,
|
|
otherwise, it is normal(1).
|
|
|
|
This object must provide for the alarm management capabilities
|
|
with a corresponding entry in the discretePropertyTable of
|
|
SCTE-HMS-PROPERTY-MIB (HMS026).
|
|
|
|
An alarm shall be recorded as an entry in the currentAlarmTable
|
|
of SCTE-HMS-PROPERTY-MIB (HMS026).
|
|
|
|
A log record shall be added as an entry in the heCommonLogTable.
|
|
|
|
An heCommonAlarmEvent notification shall be sent."
|
|
|
|
::= { heOpSwitchUnitEntry 5 }
|
|
|
|
heOpSwitchBothInputStatus OBJECT-TYPE
|
|
SYNTAX HeFaultStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integral status of both inputs.
|
|
|
|
A value is fault(2), if both input levels are below
|
|
the nominal value; otherwise, it is normal(1).
|
|
|
|
This object must provide for the alarm management capabilities
|
|
with a corresponding entry in the discretePropertyTable of
|
|
SCTE-HMS-PROPERTY-MIB (HMS026).
|
|
|
|
An alarm shall be recorded as an entry in the currentAlarmTable
|
|
of SCTE-HMS-PROPERTY-MIB (HMS026).
|
|
|
|
A log record shall be added as an entry in the heCommonLogTable.
|
|
|
|
An heCommonAlarmEvent notification shall be sent."
|
|
|
|
::= { heOpSwitchUnitEntry 6 }
|
|
|
|
heOpSwitchSelectWavelength OBJECT-TYPE
|
|
SYNTAX HeHundredthNanoMeter
|
|
UNITS "0.01 nm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wavelength feeding the particular input of the optical switch.
|
|
Typical values might be 131000 (1310 nm) and 155000 (1550 nm)."
|
|
::= { heOpSwitchUnitEntry 7 }
|
|
|
|
heOpSwitchHysteresis OBJECT-TYPE
|
|
SYNTAX HeTenthdB (-20..20)
|
|
UNITS "0.1 dB"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls switch input hysteresis amount. The amount of hysteresis
|
|
used and the ability to change it is to be determined by
|
|
the vendor."
|
|
::= { heOpSwitchUnitEntry 8 }
|
|
|
|
heOpSwitchWaitToRestoreTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "1 sec"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls hysteresis time in sec.
|
|
|
|
If in automatic switching mode and revert mode is enabled,
|
|
a switch back to the original side will be delayed for
|
|
the time specified by this object."
|
|
::= { heOpSwitchUnitEntry 9 }
|
|
|
|
|
|
|
|
-- the Optical Switch Input Table
|
|
heOpSwitchInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HeOpSwitchInputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing information about each Optical Switch
|
|
input used in an indoor environment."
|
|
::= { heOpSwitchMIBObjects 2 }
|
|
|
|
heOpSwitchInputEntry OBJECT-TYPE
|
|
SYNTAX HeOpSwitchInputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of information about each optical switch input."
|
|
INDEX { entPhysicalIndex, heOpSwitchInputIndex }
|
|
::= { heOpSwitchInputTable 1 }
|
|
|
|
HeOpSwitchInputEntry ::= SEQUENCE
|
|
{
|
|
heOpSwitchInputIndex Unsigned32,
|
|
heOpSwitchInputOpticalLevel HeTenthdBm,
|
|
heOpSwitchSetInputPowerThreshold HeTenthdBm,
|
|
heOpSwitchInputStatus HeFaultStatus,
|
|
heOpSwitchInputDescription DisplayString
|
|
}
|
|
|
|
heOpSwitchInputIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index number corresponding to the Optical Input."
|
|
::= { heOpSwitchInputEntry 1 }
|
|
|
|
heOpSwitchInputOpticalLevel OBJECT-TYPE
|
|
SYNTAX HeTenthdBm
|
|
UNITS "0.1 dBm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The measured optical input power for the optical switch."
|
|
::= { heOpSwitchInputEntry 2 }
|
|
|
|
heOpSwitchSetInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX HeTenthdBm
|
|
UNITS "0.1 dBm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Input power switchover point for this input."
|
|
::= { heOpSwitchInputEntry 3 }
|
|
|
|
heOpSwitchInputStatus OBJECT-TYPE
|
|
SYNTAX HeFaultStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integral status of the input.
|
|
|
|
A value is fault(2), if the input levels are not in
|
|
the nominal range; otherwise, it is normal(1).
|
|
|
|
This object must provide for the alarm management capabilities
|
|
with a corresponding entry in the discretePropertyTable of
|
|
SCTE-HMS-PROPERTY-MIB (HMS026).
|
|
|
|
An alarm shall be recorded as an entry in the currentAlarmTable
|
|
of SCTE-HMS-PROPERTY-MIB (HMS026).
|
|
|
|
A log record shall be added as an entry in the heCommonLogTable.
|
|
|
|
An heCommonAlarmEvent notification shall be sent."
|
|
|
|
|
|
::= { heOpSwitchInputEntry 4 }
|
|
|
|
heOpSwitchInputDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A description of the switch input. The description text is
|
|
to be determined by the equipment manufacturer. For example,
|
|
Input A or Side B."
|
|
::= { heOpSwitchInputEntry 5 }
|
|
|
|
|
|
-- the Optical Switch Output Table
|
|
heOpSwitchOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HeOpSwitchOutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table containing information about each Optical Switch
|
|
output used in an indoor environment."
|
|
::= { heOpSwitchMIBObjects 3 }
|
|
|
|
heOpSwitchOutputEntry OBJECT-TYPE
|
|
SYNTAX HeOpSwitchOutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of information about each optical switch output."
|
|
INDEX { entPhysicalIndex, heOpSwitchOutputIndex }
|
|
::= { heOpSwitchOutputTable 1 }
|
|
|
|
HeOpSwitchOutputEntry ::= SEQUENCE
|
|
{
|
|
heOpSwitchOutputIndex Unsigned32,
|
|
heOpSwitchOutputDescription DisplayString
|
|
}
|
|
|
|
heOpSwitchOutputIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index number corresponding to the Optical Output."
|
|
::= { heOpSwitchOutputEntry 1 }
|
|
|
|
|
|
heOpSwitchOutputDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A description of the switch output. The description text is
|
|
to be determined by the equipment manufacturer. For example,
|
|
Output A or Secondary Output."
|
|
::= { heOpSwitchOutputEntry 2 }
|
|
|
|
|
|
-- conformance information
|
|
heOpSwitchMIBConformance OBJECT IDENTIFIER ::= { heOpticalSwitchMIB 2 }
|
|
|
|
heOpSwitchMIBCompliances OBJECT IDENTIFIER ::= { heOpSwitchMIBConformance 1 }
|
|
|
|
heOpSwitchMIBGroups OBJECT IDENTIFIER ::= { heOpSwitchMIBConformance 2 }
|
|
|
|
heOpSwitchBasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for SNMP HMS Headend Optical
|
|
Switch entities which implement the SNMP
|
|
heOpticalSwitchMIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { heOpSwitchUnitMandatoryGroup,
|
|
heOpSwitchInputMandatoryGroup,
|
|
heOpSwitchOutputMandatoryGroup
|
|
|
|
}
|
|
::= { heOpSwitchMIBCompliances 1 }
|
|
|
|
heOpSwitchUnitMandatoryGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
heOpSwitchMode,
|
|
heOpSwitchControl,
|
|
heOpSwitchRevertEnable,
|
|
heOpSwitchState,
|
|
heOpSwitchFailoverStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main group defines heOpSwitchUnitTable objects which
|
|
are mandatory to all indoor optical switch modules."
|
|
::= { heOpSwitchMIBGroups 1 }
|
|
|
|
|
|
heOpSwitchInputMandatoryGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
heOpSwitchInputStatus,
|
|
heOpSwitchInputDescription
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main group defines heOpSwitchInputTable objects which
|
|
are mandatory to all indoor optical switch modules."
|
|
::= { heOpSwitchMIBGroups 2 }
|
|
|
|
heOpSwitchOutputMandatoryGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
heOpSwitchOutputDescription
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main group defines heOpSwitchOutputTable objects which
|
|
are mandatory to all indoor optical switch modules."
|
|
::= { heOpSwitchMIBGroups 3 }
|
|
|
|
|
|
heOpSwitchUnitGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
heOpSwitchBothInputStatus,
|
|
heOpSwitchSelectWavelength,
|
|
heOpSwitchHysteresis,
|
|
heOpSwitchWaitToRestoreTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of heOpSwitchUnitTable objects which are used to
|
|
represent the indoor optical switch module."
|
|
::= { heOpSwitchMIBGroups 4 }
|
|
|
|
heOpSwitchInputGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
heOpSwitchInputOpticalLevel,
|
|
heOpSwitchSetInputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of heOpSwitchInputTable objects which are used to
|
|
represent the indoor optical switch module."
|
|
::= { heOpSwitchMIBGroups 5 }
|
|
|
|
END
|