-- Module Name: HMS119R7.MIB (SCTE 85-4)
-- SCTE Status: Draft Revision 7
SCTE-HMS-HE-OPTICAL-SWITCH-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
OBJECT-TYPE, MODULE-IDENTITY, Unsigned32, Integer32
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
entPhysicalIndex
FROM ENTITY-MIB
HeFaultStatus,HeHundredthNanoMeter,
HeTenthdB, HeTenthdBm, HeOnOffControl
FROM SCTE-HMS-HEADENDIDENT-MIB
heOpticalSwitchGroup
FROM SCTE-HMS-HE-OPTICS-MIB;
heOpticalSwitchMIB MODULE-IDENTITY
LAST-UPDATED "200309110000Z" -- Sep 11, 2003
ORGANIZATION "SCTE HMS Working Group"
CONTACT-INFO
"SCTE HMS Subcommittee, Chairman
mailto: standards@SCTE.org"
DESCRIPTION
" Change Log:
1. Added Unsigned32 and Integer32 to IMPORTS
2. Removed TEXTUAL-CONVENTION from IMPORTS
3. Corrected 4 digit date code defined in RFC2578
4. heOpSwitchWaitToRestoreTime is changed to Integer32
instead of INTEGER
5. Removed extra commas in heOpSwitchUnitMandatoryGroup,
heOpSwitchUnitGroup and heOpSwitchInputGroup
6. Changed OID of heOpSwitchMIBCompliances to 1 instead of 2
7. Changed the text description of SNMPv2 to SNMP for
heOpSwitchBasicCompliance MODULE-COMPLIANCE"
REVISION "200309110000Z"
DESCRIPTION
" Change Log:
1. Fixed all compile errors
2. Defined heOpSwitchInputIndex in the input entry sequence
3. Defined heOpSwitchOutputIndex in the Output entry sequence"
REVISION "200305290000Z"
DESCRIPTION
"The MIB module for the HMS HE Optical Switch module
entities.
This MIB module is for representing optical
switch equipment present in the headend (or indoor)
and is supported by a SNMP agent.
This MIB is limited in its scope and intended to
describe an A-B (2 input and 1 output) or a crossbar
optical switch. Up to 2 optical inputs and 2 outputs
are supported. Any devices with more than 2 optical
inputs or outputs shall be covered by another MIB.
This MIB does not intend to dictate all of the nuances
involved in changing control settings (automatic or
manual mode, changing switch controls in each possible
mode combination). The most common desired behaviors
are noted but specific switch operation and behavior
are left to the optical switch vendors.
Not all control enumerations must be supported. This
is noted in the variables that have optional
enumerations.
Refer to the associated notes for information on what
SNMP responses should be returned for unsupported
enumerations."
REVISION "200304250000Z" -- April 25, 2003
DESCRIPTION
"Change log:
1. Beautified MIB. Made sure all lines are 80 columns or
less.
2. Removed default enumeration from heOpSwitchControl
and heOpSwitchMode.
3. Corrected name of the heOpSwitchWaitToRestoreTime.
It was erroneously left as heOpSwitchHysteresisTime in
R3.
4. Removed instructions regarding the SET response for
heOpSwitchMode and heOpSwitchRevertEnable. The
information is not necessary since the variables could
be set as read-only.
5. Edited MIB description to make it more clear.
6. Adopted the standard HMS MIBlanguage to indicate
when a variable must have an entry in the discrete
properties.
7. Added comment header at top of file. SCTE revision is
set to one.
8. Added HeHundredthNanoMeter and HeOnOffControl to IMPORTS.
Removed HeTenthCentigrade from IMPORTS"
REVISION "200301210000Z" -- January 21, 2003
DESCRIPTION
"Change log:
1. Beautified MIB. Made sure all lines are 80 columns or
less.
2. Removed default enumeration from heOpSwitchControl
and heOpSwitchMode.
3. Corrected name of the heOpSwitchWaitToRestoreTime.
It was erroneously left as heOpSwitchHysteresisTime in
R3.
4. Removed instructions regarding the SET response for
heOpSwitchMode and heOpSwitchRevertEnable. The
information is not necessary since the variables could
be set as read-only.
5. Edited MIB description to make it more clear.
6. Adopted the standard HMS MIBlanguage to indicate
when a variable must have an entry in the discrete
properties.
7. Added comment header at top of file. SCTE revision is
set to one.
"
REVISION "200212040000Z" -- December 04, 2002
DESCRIPTION
"Change log:
As a result of discussions at the SCTE HMS Subcommittee
meeting held 10/10/2002
1. Reorganized optical switch objects into three tables:
heOpSwitchUnitTable,heOpSwitchInputTable and
heOpSwitchOutputTable.
2. Revised HMS119 to represent an optical AB switch or
crossbar switch with 1-2 inputs and 1-2 outputs. Switches
with more than two inputs or outputs must be covered by
another MIB. This was decided by the HMS Subcommittee
at the 10/10/2002 meeting as a way to manage the
complexity of the switch device.
3. Simplified the heOpSwitchControl variable. It was
broken up because the enumerations were becoming too
cumbersome for each possible switch setting. Removed
some enumerations and created heOpSwitchMode and
heOpRevertEnable to include those removed
enumerations/controls.
4. Added heOpSwitchFailoverStatus. Made it mandatory
to include a discrete property entry.
5. Made it mandatory to include a discrete property
entry if heOpSwitchBothInputStatus is supported.
6. Replaced the heOpSwitchSelectWavelength description
with the same description used in
the optical receiver MIB (SCTE-HMS-HE-OPTICAL-RECEIVER-MIB
HMS113).
7. Modified the heOpSwitchBasicCompliance mandatory
groups definition to include newly defined mandatory groups
associated with the added tables defined in change 1
above.
8. Added heOpSwitchUnitMandatoryGroup,
heOpSwitchInputMandatoryGroup and
heOpSwitchOutputMandatoryGroup to heOpSwitchMIBGroups.
9. Added heOpSwitchUnitGroup, heOpSwitchInputGroup and
heOpSwitchOutputGroup to heOpSwitchMIBGroups
10. Modified contact list (added Motorola editor of R3).
11. Removed heOpSwitchModuleTemp since it was redundant.
12. Removed ranges on HeTenthdBm type variables since the
definition already include ranges.
13. Modified the description of this MIB.
14. Expanded comments to describe how the optical switch
is modeled by the added tables.
This version obsoletes 'HMS119R2.mib'.
This version published as 'HMS119R3.mib'."
REVISION "200210060000Z" -- October 06, 2002
DESCRIPTION
"Change log:
1. Changed prefix of all variables to 'heOpSwitch'.
2. Introduced heOpSwitchMIBObjects branch.
3. Made all MIB objects grow off that branch.
4. Changed OID of heOpSwitchMIBConformance.
5. Changed index clause of heOpSwitchUnitEntry.
6. Changed syntax and description of
heOpSwitchBothInputStatus.
7. Beautified MIB.
This version obsoletes 'HMS119R1.mib'.
This version published as 'HMS119R2.mib'."
REVISION "200209250000Z"
DESCRIPTION
"Initial version of SCTE-HMS-HE-Optical-Switch-MIB.
This version is published as 'HMS119R1.mib'."
::= { heOpticalSwitchGroup 1 }
heOpSwitchMIBObjects OBJECT IDENTIFIER ::= { heOpticalSwitchMIB 1}
-- Every optical switch is modeled by the tables presented
-- in this MIB module. These tables extend the entPhysicalTable
-- according to RFC 2737. The extension index entPhysicalIndex uniquely
-- identifies the optical switch.
-- Every optical switch is also modeled by the following tables:
-- entPhysicalEntry - 1 row; (defined in document: RFC2737)
-- heCommonEntry - 1 row. (defined in document: HMS111)
-- Every optical switch module will have its alarms modeled by the table:
-- propertyEntry - x rows; (defined in document: HMS026)
-- (where x is the nos. of alarmable analog properties supported
-- by the optical switch)
-- discretePropertyEntry - y rows; (defined in document: HMS026)
-- (where y is the nos. of alarmable digital properties supported by
-- the optical switch)
-- Every optical switch module will have a list of currently active
-- alarms modeled by the table:
-- currentAlarmEntry - z rows; (defined in document: HMS026)
-- (where z is the nos. of current active alarms in the optical
-- switch)
-- Thus, an A-B optical switch (2 optical inputs and one optical output)
-- will be represented by one row in entPhysicalTable, one row in
-- heCommonTable, one row in heOpSwitchUnitTable, two rows in
-- heOpSwitchInputTable and one row in heOpSwitchOutputTable.
-- Additionally, a crossbar optical switch (2 inputs and 2 outputs)
-- will be represented by one row in entPhysicalTable, one row in
-- heCommonTable, one row in heOpSwitchUnitTable, two rows
-- in heOpSwitchInputTable and two rows in heOpSwitchOutputTable.
-- Correlation of outputs and inputs are indicated by the heOpSwitchState
-- variable. Correlation of physical inputs and outputs to
-- heOpSwitchInputTable and heOpSwitchOutputTables rows is indicated
-- by the heOpSwitchInputDescription and heOpSwitchOutputDescription
-- variables.
-- the Optical Switch Unit Table
heOpSwitchUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF HeOpSwitchUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about Optical Switch used
in an indoor environment."
::= { heOpSwitchMIBObjects 1 }
heOpSwitchUnitEntry OBJECT-TYPE
SYNTAX HeOpSwitchUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of information about each optical switch."
INDEX { entPhysicalIndex }
::= { heOpSwitchUnitTable 1 }
HeOpSwitchUnitEntry ::= SEQUENCE {
heOpSwitchMode INTEGER,
heOpSwitchControl INTEGER,
heOpSwitchRevertEnable HeOnOffControl,
heOpSwitchState INTEGER,
heOpSwitchFailoverStatus HeFaultStatus,
heOpSwitchBothInputStatus HeFaultStatus,
heOpSwitchSelectWavelength HeHundredthNanoMeter,
heOpSwitchHysteresis HeTenthdB,
heOpSwitchWaitToRestoreTime Integer32
}
heOpSwitchMode OBJECT-TYPE
SYNTAX INTEGER {
automatic(1),
manual(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls and/or reports the switching mode. If
automatic(1), the optical switch will evaluate the optical
input status and make the decision to affect the switch state.
If set to manual(2), the optical switch will not affect the
switch state itself."
::= { heOpSwitchUnitEntry 1 }
heOpSwitchControl OBJECT-TYPE
SYNTAX INTEGER {
pathA(1),
pathB(2),
cross(3),
bar(4),
bothA(5),
bothB(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the intended state of the Optical Switch. The effect
of this control will depend on the value of heOpSwitchMode.
If heOpSwitchMode is set to automatic, the value this
control is set to will be the preferred setting. If it is
set to manual, the switch will assume this setting. Actual
switch operation while changing switch control value(s)
is up to the equipment vendor. For example, if the switch
is in manual mode and the operator tries to connect the
output to an invalid input, the switch may or may
not change state.
Not all enumerations must be supported. For example, an
A-B optical switch may support only the pathA and pathB
enumerations while a cross-bar switch may support cross,
bar, bothA or bothB or only cross and bar but not pathA
and pathB enumerations. See the note below about the
expected SNMP response.
A value pathA(1) connects the switch output to side A
(first input) of the switch. This enumeration is intended
for use by an A-B switch.
A value pathB(2) connects the switch output to side B
(second input) of the switch. This enumeration is intended
for use by an A-B switch.
A value cross(3) connects the switch outputs to the inputs
as follows:
Side A (first or primary) output is connected to side B
(second or alternate) input.
Side B (second or alternate) output is connected to
side A (first or primary) input.
This enumeration is intended for use by a cross-bar switch.
A value bar(4) connects the switch outputs to the inputs as
follows:
Side A (first or primary) output is connected to side A
(first or primary) input.
Side B (second or alternate) output is connected to
side B (second or alternate) input.
This enumeration is intended for use by a cross-bar switch.
A value bothA(5) connects the switch outputs to the inputs as
follows:
Side A (first or primary) output is connected to side A
(first or primary) input.
Side B (second or alternate) output is connected to
side A (first or primary) input.
This enumeration is intended for use by a cross-bar switch.
A value bothB(6) connects the switch outputs to the inputs
as follows:
Side A (first or primary) output is connected to side B
(second or alternate) input.
Side B (second or alternate) output is connected to
side B (second or alternate) input.
This enumeration is intended for use by a cross-bar switch.
*** IMPORTANT ***
It is NOT required that an optical switch support all
enumerations. A SET request for an unsupported value shall
yield a badValue(3) error by an SNMPv1 agent or an
inconsistentValue(12) by an SNMPv2 agent."
::= { heOpSwitchUnitEntry 2 }
heOpSwitchRevertEnable OBJECT-TYPE
SYNTAX HeOnOffControl
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the use of revertive switching.
If set to on, the switch will attempt to go back to the
preferred settings indicated by heOpSwitchControl if
heOpSwitchMode is set to automatic, and the input status
of the preferred input is normal. The switch will not
attempt to revert to the settings indicated by
heOpSwitchControl until heOpSwitchWaitToRestoreTime
(if supported) has expired since the preferred input was
restored to normal levels.
If set to off, the switch will not attempt to go back to
the preferred settings indicated by heOpSwitchControl if
heOpSwitchMode is set to automatic, and the input status
of the preferred input is normal.
"
::= { heOpSwitchUnitEntry 3 }
heOpSwitchState OBJECT-TYPE
SYNTAX INTEGER {
pathA(1),
pathB(2),
cross(3),
bar(4),
bothA(5),
bothB(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports the state of the Optical Switch. Not all enumerations
must be supported. For example, an A-B optical switch may
support only the pathA and pathB enumerations while a
cross-bar switch may support cross, bar, bothA or bothB or
only cross and bar but not pathA and pathB enumerations.
A value pathA(1) indicates that the switch output is being
fed by side A (first input) of the switch. This enumeration
is intended for use by an A-B switch.
A value pathB(2) indicates that the switch output is being
fed by side B (second input) of the switch. This enumeration
is intended for use by an A-B switch.
A value cross(3) indicates that the switch outputs are fed as
follows:
Side A (first or primary) output is connected to side B
(second or alternate) input.
Side B (second or alternate) output is connected to side A
(first or primary) input.
This enumeration is intended for use by a cross-bar switch.
A value bar(4) indicates that the switch outputs are fed as
follows:
Side A (first or primary) output is connected to side A
(first or primary) input.
Side B (second or alternate) output is connected to side B
(second or alternate) input.
This enumeration is intended for use by a cross-bar switch.
A value bothA(5) indicates that the switch outputs are fed as
follows:
Side A (first or primary) output is connected to side A
(first or primary) input.
Side B (second or alternate) output is connected to side A
(first or primary) input.
This enumeration is intended for use by a cross-bar switch.
A value bothB(6) indicates that the switch outputs are fed as
follows:
Side A (first or primary) output is connected to side B
(second or alternate) input.
Side B (second or alternate) output is connected to side B
(second or alternate) input.
This enumeration is intended for use by a cross-bar switch."
::= { heOpSwitchUnitEntry 4 }
heOpSwitchFailoverStatus OBJECT-TYPE
SYNTAX HeFaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The integral status of both inputs.
A value is fault(2), if current switch state heOpSwitchState
is different than the preferred setting heOpSwitchControl,
otherwise, it is normal(1).
This object must provide for the alarm management capabilities
with a corresponding entry in the discretePropertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (HMS026).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { heOpSwitchUnitEntry 5 }
heOpSwitchBothInputStatus OBJECT-TYPE
SYNTAX HeFaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The integral status of both inputs.
A value is fault(2), if both input levels are below
the nominal value; otherwise, it is normal(1).
This object must provide for the alarm management capabilities
with a corresponding entry in the discretePropertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (HMS026).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { heOpSwitchUnitEntry 6 }
heOpSwitchSelectWavelength OBJECT-TYPE
SYNTAX HeHundredthNanoMeter
UNITS "0.01 nm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Wavelength feeding the particular input of the optical switch.
Typical values might be 131000 (1310 nm) and 155000 (1550 nm)."
::= { heOpSwitchUnitEntry 7 }
heOpSwitchHysteresis OBJECT-TYPE
SYNTAX HeTenthdB (-20..20)
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls switch input hysteresis amount. The amount of hysteresis
used and the ability to change it is to be determined by
the vendor."
::= { heOpSwitchUnitEntry 8 }
heOpSwitchWaitToRestoreTime OBJECT-TYPE
SYNTAX Integer32
UNITS "1 sec"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls hysteresis time in sec.
If in automatic switching mode and revert mode is enabled,
a switch back to the original side will be delayed for
the time specified by this object."
::= { heOpSwitchUnitEntry 9 }
-- the Optical Switch Input Table
heOpSwitchInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF HeOpSwitchInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about each Optical Switch
input used in an indoor environment."
::= { heOpSwitchMIBObjects 2 }
heOpSwitchInputEntry OBJECT-TYPE
SYNTAX HeOpSwitchInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of information about each optical switch input."
INDEX { entPhysicalIndex, heOpSwitchInputIndex }
::= { heOpSwitchInputTable 1 }
HeOpSwitchInputEntry ::= SEQUENCE
{
heOpSwitchInputIndex Unsigned32,
heOpSwitchInputOpticalLevel HeTenthdBm,
heOpSwitchSetInputPowerThreshold HeTenthdBm,
heOpSwitchInputStatus HeFaultStatus,
heOpSwitchInputDescription DisplayString
}
heOpSwitchInputIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index number corresponding to the Optical Input."
::= { heOpSwitchInputEntry 1 }
heOpSwitchInputOpticalLevel OBJECT-TYPE
SYNTAX HeTenthdBm
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured optical input power for the optical switch."
::= { heOpSwitchInputEntry 2 }
heOpSwitchSetInputPowerThreshold OBJECT-TYPE
SYNTAX HeTenthdBm
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input power switchover point for this input."
::= { heOpSwitchInputEntry 3 }
heOpSwitchInputStatus OBJECT-TYPE
SYNTAX HeFaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The integral status of the input.
A value is fault(2), if the input levels are not in
the nominal range; otherwise, it is normal(1).
This object must provide for the alarm management capabilities
with a corresponding entry in the discretePropertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (HMS026).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { heOpSwitchInputEntry 4 }
heOpSwitchInputDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the switch input. The description text is
to be determined by the equipment manufacturer. For example,
Input A or Side B."
::= { heOpSwitchInputEntry 5 }
-- the Optical Switch Output Table
heOpSwitchOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF HeOpSwitchOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about each Optical Switch
output used in an indoor environment."
::= { heOpSwitchMIBObjects 3 }
heOpSwitchOutputEntry OBJECT-TYPE
SYNTAX HeOpSwitchOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of information about each optical switch output."
INDEX { entPhysicalIndex, heOpSwitchOutputIndex }
::= { heOpSwitchOutputTable 1 }
HeOpSwitchOutputEntry ::= SEQUENCE
{
heOpSwitchOutputIndex Unsigned32,
heOpSwitchOutputDescription DisplayString
}
heOpSwitchOutputIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index number corresponding to the Optical Output."
::= { heOpSwitchOutputEntry 1 }
heOpSwitchOutputDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the switch output. The description text is
to be determined by the equipment manufacturer. For example,
Output A or Secondary Output."
::= { heOpSwitchOutputEntry 2 }
-- conformance information
heOpSwitchMIBConformance OBJECT IDENTIFIER ::= { heOpticalSwitchMIB 2 }
heOpSwitchMIBCompliances OBJECT IDENTIFIER ::= { heOpSwitchMIBConformance 1 }
heOpSwitchMIBGroups OBJECT IDENTIFIER ::= { heOpSwitchMIBConformance 2 }
heOpSwitchBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP HMS Headend Optical
Switch entities which implement the SNMP
heOpticalSwitchMIB."
MODULE -- this module
MANDATORY-GROUPS { heOpSwitchUnitMandatoryGroup,
heOpSwitchInputMandatoryGroup,
heOpSwitchOutputMandatoryGroup
}
::= { heOpSwitchMIBCompliances 1 }
heOpSwitchUnitMandatoryGroup OBJECT-GROUP
OBJECTS {
heOpSwitchMode,
heOpSwitchControl,
heOpSwitchRevertEnable,
heOpSwitchState,
heOpSwitchFailoverStatus
}
STATUS current
DESCRIPTION
"The main group defines heOpSwitchUnitTable objects which
are mandatory to all indoor optical switch modules."
::= { heOpSwitchMIBGroups 1 }
heOpSwitchInputMandatoryGroup OBJECT-GROUP
OBJECTS {
heOpSwitchInputStatus,
heOpSwitchInputDescription
}
STATUS current
DESCRIPTION
"The main group defines heOpSwitchInputTable objects which
are mandatory to all indoor optical switch modules."
::= { heOpSwitchMIBGroups 2 }
heOpSwitchOutputMandatoryGroup OBJECT-GROUP
OBJECTS {
heOpSwitchOutputDescription
}
STATUS current
DESCRIPTION
"The main group defines heOpSwitchOutputTable objects which
are mandatory to all indoor optical switch modules."
::= { heOpSwitchMIBGroups 3 }
heOpSwitchUnitGroup OBJECT-GROUP
OBJECTS {
heOpSwitchBothInputStatus,
heOpSwitchSelectWavelength,
heOpSwitchHysteresis,
heOpSwitchWaitToRestoreTime
}
STATUS current
DESCRIPTION
"The collection of heOpSwitchUnitTable objects which are used to
represent the indoor optical switch module."
::= { heOpSwitchMIBGroups 4 }
heOpSwitchInputGroup OBJECT-GROUP
OBJECTS {
heOpSwitchInputOpticalLevel,
heOpSwitchSetInputPowerThreshold
}
STATUS current
DESCRIPTION
"The collection of heOpSwitchInputTable objects which are used to
represent the indoor optical switch module."
::= { heOpSwitchMIBGroups 5 }
END