22135 lines
629 KiB
Plaintext
22135 lines
629 KiB
Plaintext
RAD-Mpmx-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- It is RAD's intent to encourage the widespread use of
|
|
-- this Specification in connection with the management of
|
|
-- RAD products. RAD grants vendors, end-users,
|
|
-- and other interested parties a non-exclusive license to
|
|
-- use this Specification in connection with the management
|
|
-- of RAD products.
|
|
|
|
-- This Specification is supplied "as is," and RAD makes
|
|
-- no warranty, either express or implied, as to the use,
|
|
-- operation, condition, or performance of the Specification.
|
|
|
|
|
|
IMPORTS
|
|
|
|
ifAlias, ifIndex FROM IF-MIB
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
|
Integer32, Counter32, IpAddress,
|
|
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE, OBJECT-IDENTITY FROM SNMPv2-SMI
|
|
DisplayString, RowStatus, TruthValue FROM SNMPv2-TC
|
|
radWan, wanGen FROM RAD-SMI-MIB
|
|
agnLed, alarmEventLogSourceName, alarmEventLogAlarmOrEventId,
|
|
alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime,
|
|
alarmEventReason FROM RAD-GEN-MIB
|
|
CardType, ProtectLastSwitchReasonType FROM RAD-TC;
|
|
|
|
|
|
chasWanGen MODULE-IDENTITY
|
|
LAST-UPDATED "201609182024Z" -- September 18, 2016
|
|
ORGANIZATION "RAD Data Communications Ltd."
|
|
CONTACT-INFO
|
|
"System Department
|
|
|
|
Email: mibs@rad.com
|
|
Postal: RAD Data Communications Ltd.
|
|
24 Raoul Wallenberg St.
|
|
Tel-Aviv 6971920
|
|
Israel
|
|
|
|
Phone: +972-3-645-5421
|
|
Fax: +972-3-760-7844"
|
|
DESCRIPTION
|
|
"Megaplex Maccess MIB."
|
|
::= { wanGen 1 }
|
|
|
|
|
|
muxHub OBJECT IDENTIFIER ::= {radWan 2}
|
|
|
|
-- ----------------------------------------------------------------------------------------------
|
|
-- chasWanGen OBJECT IDENTIFIER ::= {wanGen 1}
|
|
agnWanGen OBJECT IDENTIFIER ::= {wanGen 2}
|
|
mdlWanGen OBJECT IDENTIFIER ::= {wanGen 3}
|
|
prtWanGen OBJECT IDENTIFIER ::= {wanGen 4}
|
|
mapWanGen OBJECT IDENTIFIER ::= {wanGen 5}
|
|
diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6}
|
|
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} defined RAD-Diverse-IF-MIB
|
|
|
|
--ethIf OBJECT IDENTIFIER ::= {diverseIfWanGen 1} (see ethif.txt)
|
|
--sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} (see radsonet.txt)
|
|
--ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} (see radds3.txt)
|
|
--ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} (see radds1.txt)
|
|
--hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} (see radhdlc.txt)
|
|
--v51If OBJECT IDENTIFIER ::= {diverseIfWanGen 6} (see v51.txt)
|
|
--ip2If OBJECT IDENTIFIER ::= {diverseIfWanGen 7} (see ipmux.txt)
|
|
--broadbandIf OBJECT IDENTIFIER ::= {diverseIfWanGen 8} (see bdband.txt)
|
|
--r2If OBJECT IDENTIFIER ::= {diverseIfWanGen 9} (see r2.txt)
|
|
--adslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 10} (see radadsl.txt)
|
|
--sdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 11} (see radsdsl.txt)
|
|
--shdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 12} (see radshdsl.txt)
|
|
--voiceIf OBJECT IDENTIFIER ::= {diverseIfWanGen 13} (see voiceIf.txt)
|
|
--gsmInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 14} (see radGsm.txt)
|
|
--ds0BundleIf OBJECT IDENTIFIER ::= {diverseIfWanGen 15} (see radds0.txt)
|
|
--pdhInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 16} (see radpdh.txt)
|
|
|
|
--voipWanGen OBJECT IDENTIFIER ::= {wanGen 7} (see voip.txt)
|
|
|
|
|
|
statAgnGen OBJECT IDENTIFIER ::= {agnWanGen 1}
|
|
cnfgAgnGen OBJECT IDENTIFIER ::= {agnWanGen 2}
|
|
cmprAgnGen OBJECT IDENTIFIER ::= {agnWanGen 3}
|
|
alrBuffGen OBJECT IDENTIFIER ::= {agnWanGen 4}
|
|
agnFlipDb OBJECT IDENTIFIER ::= {agnWanGen 5}
|
|
agnSa OBJECT IDENTIFIER ::= {agnWanGen 6}
|
|
agnListDecoding OBJECT IDENTIFIER ::= {agnWanGen 7}
|
|
agnSystemDlci OBJECT IDENTIFIER ::= {agnWanGen 8}
|
|
agnVoiceSwitching OBJECT IDENTIFIER ::= {agnWanGen 9}
|
|
agnSigProfile OBJECT IDENTIFIER ::= {agnWanGen 10}
|
|
agnSystemTs OBJECT IDENTIFIER ::= {agnWanGen 11}
|
|
systemVoice OBJECT IDENTIFIER ::= {agnWanGen 12}
|
|
|
|
statMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 1}
|
|
cnfgMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 2}
|
|
cmprMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 3}
|
|
|
|
|
|
statPrtGen OBJECT IDENTIFIER ::= {prtWanGen 1}
|
|
cnfgPrtGen OBJECT IDENTIFIER ::= {prtWanGen 2}
|
|
cmprPrtGen OBJECT IDENTIFIER ::= {prtWanGen 3}
|
|
|
|
--statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3} - Statistics of Ports
|
|
--prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1}
|
|
--prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2}
|
|
--prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3}
|
|
--prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4}
|
|
|
|
agnMux OBJECT IDENTIFIER ::= {muxHub 1}
|
|
mdlMux OBJECT IDENTIFIER ::= {muxHub 2}
|
|
prtMux OBJECT IDENTIFIER ::= {muxHub 3}
|
|
|
|
--cnfgMdlMux OBJECT IDENTIFIER ::= {mdlMux 1}
|
|
--statMdlMux OBJECT IDENTIFIER ::= {mdlMux 2}
|
|
|
|
statPrtMux OBJECT IDENTIFIER ::= {prtMux 1}
|
|
cnfgPrtMux OBJECT IDENTIFIER ::= {prtMux 2}
|
|
|
|
statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3}
|
|
|
|
prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1}
|
|
prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2}
|
|
prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3}
|
|
prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4}
|
|
|
|
--
|
|
|
|
--prtSExHsfStatTable OBJECT IDENTIFIER ::= {statPrtMux 6}
|
|
--prtIsdnStatusTable OBJECT IDENTIFIER ::= {statPrtMux 16}
|
|
|
|
--
|
|
|
|
prtClCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 1}
|
|
prtPh1MlCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 2} --MPH1/e1/t1
|
|
prtPhPlCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 3} --MPH1,MPH3,MPL6
|
|
prtLs2Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 4} --LS2 family
|
|
--prtVc2CnfgTable OBJECT IDENTIFIER ::= {cnfgPrtMux 5}
|
|
--prtHsfCnfgTable OBJECT IDENTIFIER ::= {cnfgPrtMux 6}
|
|
prtHs4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 7}
|
|
prtHsiCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 8}
|
|
prtPVc4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 9}
|
|
prtHsrCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 10}
|
|
prtMbeCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 11}
|
|
prtTreCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 12}
|
|
prtLs6Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 13}
|
|
prtVc3Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 14}
|
|
prtVcPbxCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 15}
|
|
prtIsdnCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 16}
|
|
prtLogicalCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 17}
|
|
prtFrPlusCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 18}
|
|
prtMl4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 19}
|
|
prtAcmCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 20}
|
|
prtE2Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 21}
|
|
prtLanWanCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 22}
|
|
|
|
--
|
|
-- Wan chassis general information
|
|
--
|
|
|
|
chasVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An ASCII string for description and display of the agent chassis version."
|
|
::= { chasWanGen 1 }
|
|
|
|
chasTotalNoOfSlt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the number of physical slots in the
|
|
chassis."
|
|
::= { chasWanGen 2 }
|
|
|
|
chasTotalNoOfIoSlt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the total number of physical IO slots
|
|
in the chassis, (not all slots hardware should be occupied
|
|
and active) ."
|
|
::= { chasWanGen 3 }
|
|
|
|
chasTotalNoOfPsSlt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the number of physical Power Supply
|
|
slots in the chassis."
|
|
::= { chasWanGen 4 }
|
|
|
|
chasTotalNoOfClSlt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the number of physical Common Logic slots in the
|
|
chassis."
|
|
::= { chasWanGen 5 }
|
|
|
|
--
|
|
-- Wan agent status general information
|
|
--
|
|
agnSDateFormat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ddMMYYYY (1),
|
|
mmDDYYYY (2),
|
|
yyyyDDMM (3),
|
|
yyyyMMDD (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the date and time format used for the
|
|
agnSDateAndTimeCmd and for the alarm history report."
|
|
::= { statAgnGen 1 }
|
|
|
|
agnSDateCmd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the current date as it is known by the
|
|
agent using its own real-time clock. The format would be as
|
|
specified by the agnSDateFormat.
|
|
This parameter can be set for time synchronization between
|
|
the NMS and the Agent."
|
|
::= { statAgnGen 2 }
|
|
|
|
agnSTimeCmd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the current time as it is known by the
|
|
agent using its own real-time clock.
|
|
This parameter can be set for time synchronization between
|
|
the NMS and the Agent."
|
|
::= { statAgnGen 3 }
|
|
|
|
agnSActiveCnfg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry specifies the unique identifier of the configuration,
|
|
that is currently active and running."
|
|
::= { statAgnGen 4 }
|
|
-- return 1 (db1) in phase I
|
|
|
|
agnSEditCnfg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the unique identifier of the
|
|
configuration that is currently loaded into the tmp working
|
|
space for manipulation and update operations. Value of 255
|
|
means no config. is under editing process."
|
|
::= { statAgnGen 5 }
|
|
-- return 1 (db1) in phase I
|
|
|
|
agnSLastCnfgFlipTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the Date & Time of the last flip to the
|
|
current configuration at the agent."
|
|
::= { statAgnGen 6 }
|
|
-- return sysUpTime in phase I
|
|
|
|
agnSLastCnfgFlipCause OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry describes the flip's cause."
|
|
::= { statAgnGen 7 }
|
|
-- In phase I return two causes:
|
|
-- Power up
|
|
-- Update Db
|
|
|
|
agnSEditBy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
snmp (2),
|
|
terCon1 (3),
|
|
terCon2 (4),
|
|
terInbandCon1 (5),
|
|
terInbandCon2 (6),
|
|
lcd (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates which MMI application is working on the
|
|
edited config.
|
|
The editing phase starts at the first modify operation and
|
|
ends after an update(load) operation."
|
|
::= { statAgnGen 8 }
|
|
|
|
agnSClkSrc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
master (1),
|
|
fallback(2),
|
|
internal(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the source of the system clock."
|
|
::= { statAgnGen 9 }
|
|
|
|
agnSAlrStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the alarm state in the agent level, i.e. lower
|
|
level (card/port) alarms not included.
|
|
critical(7) - when there is at least one active (state ON)
|
|
critical alarm,
|
|
otherwise it will be set to
|
|
major(5) - when there is at least one active (state ON)
|
|
major alarm,
|
|
otherwise it will be set to
|
|
minor(4) - if there is at least one active (state ON) minor
|
|
alarm,
|
|
otherwise it will be set to
|
|
warning(6) - if there is at least one active (state ON)
|
|
warning alarm,
|
|
otherwise it will be set to
|
|
event(3) - if there was at least one alarm event (including
|
|
state on,off events) since the last clear operation."
|
|
::= { statAgnGen 10 }
|
|
|
|
agnSAlrStatusAll OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the alarm state of the entire agent, i.e.
|
|
including card and port alarms status.
|
|
critical(7) - when there is at least one active (state ON)
|
|
critical alarm,
|
|
otherwise it will be set to
|
|
major(5) - when there is at least one active (state ON)
|
|
major alarm,
|
|
otherwise it will be set to
|
|
minor(4) - if there is at least one active (state ON) minor
|
|
alarm,
|
|
otherwise it will be set to
|
|
warning(6) - if there is at least one active (state ON)
|
|
warning alarm,
|
|
otherwise it will be set to
|
|
event(3) - if there was at least one alarm event (including
|
|
state on,off events) since the last clear operation."
|
|
::= { statAgnGen 11 }
|
|
|
|
agnSMaskedAlrStat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the alarm state in the agent level,[ i.e. lower
|
|
level (card/port) alarms not included] including Masked
|
|
alarms.
|
|
critical(7) - when there is at least one active (state ON)
|
|
critical alarm,
|
|
otherwise it will be set to
|
|
major(5) - when there is at least one active (state ON)
|
|
major alarm,
|
|
otherwise it will be set to
|
|
minor(4) - if there is at least one active (state ON) minor
|
|
alarm,
|
|
otherwise it will be set to
|
|
warning(6) - if there is at least one active (state ON)
|
|
warning alarm,
|
|
otherwise it will be set to
|
|
event(3) - if there was at least one alarm event (including
|
|
state on,off events) since the last clear operation."
|
|
::= { statAgnGen 12 }
|
|
|
|
agnSMaskedAlrStatAll OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the alarm state of the entire agent, i.e.
|
|
including card and port alarms status,including
|
|
Masked alarms.
|
|
critical(7) - when there is at least one active (state ON)
|
|
critical alarm,
|
|
otherwise it will be set to
|
|
major(5) - when there is at least one active (state ON)
|
|
major alarm,
|
|
otherwise it will be set to
|
|
minor(4) - if there is at least one active (state ON) minor
|
|
alarm,
|
|
otherwise it will be set to
|
|
warning(6) - if there is at least one active (state ON)
|
|
warning alarm,
|
|
otherwise it will be set to
|
|
event(3) - if there was at least one alarm event (including
|
|
state on,off events) since the last clear operation."
|
|
::= { statAgnGen 13 }
|
|
|
|
agnSTstStatAll OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"on(3) - when there is at least one test in progress in one
|
|
of the agent cards,
|
|
otherwise the value will be off(2)."
|
|
::= { statAgnGen 14 }
|
|
|
|
agnSAlrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnSAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of agent related alarms and indications for alarms at
|
|
system level."
|
|
::= { statAgnGen 15 }
|
|
|
|
agnSAlrEntry OBJECT-TYPE
|
|
SYNTAX AgnSAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { agnSAlrIdx}
|
|
::= { agnSAlrTable 1}
|
|
|
|
AgnSAlrEntry ::=
|
|
SEQUENCE {
|
|
agnSAlrIdx Integer32,
|
|
agnSAlrCodeDescription DisplayString,
|
|
agnSAlrCode Integer32,
|
|
agnSAlrSeverity INTEGER,
|
|
agnSAlrState INTEGER,
|
|
agnSAlrCounter Integer32,
|
|
agnSAlrMask INTEGER,
|
|
agnSAlrInvert INTEGER
|
|
}
|
|
|
|
agnSAlrIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify an entry in the alarm status table
|
|
of the agent."
|
|
::= { agnSAlrEntry 1 }
|
|
|
|
agnSAlrCodeDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is a full text description of the alarm .
|
|
The alarm description includes the following information:
|
|
alarm code, alarm text, alarm severity, Masked or Inverted
|
|
flag and counter."
|
|
::= { agnSAlrEntry 2 }
|
|
|
|
agnSAlrCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A code identifying the alarm of an entry in the alarm status
|
|
table at system level."
|
|
::= { agnSAlrEntry 3 }
|
|
|
|
agnSAlrSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the alarm."
|
|
::= { agnSAlrEntry 4 }
|
|
|
|
agnSAlrState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of the alarm."
|
|
::= { agnSAlrEntry 5 }
|
|
|
|
agnSAlrCounter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter - how many times the alarm occured since last
|
|
clear operation.
|
|
ON and OFF Alarm will be counted separately."
|
|
::= { agnSAlrEntry 6 }
|
|
|
|
agnSAlrMask OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm mask : on/off."
|
|
::= { agnSAlrEntry 7 }
|
|
|
|
agnSAlrInvert OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm invert : on/off."
|
|
::= { agnSAlrEntry 8 }
|
|
|
|
|
|
agnSClearAlrCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to ON, enforce a clear operation on
|
|
all the agent(general) events. General alarms are alarms
|
|
which are not specific to a card or port. The clear
|
|
operation will not be applied for masked/inverted alarms."
|
|
::= { statAgnGen 16 }
|
|
|
|
agnSClearAllAlrCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to ON, enforce a clear operation on
|
|
all MUX alarm events at the levels of agent, slots and ports.
|
|
The clear operation will not be applied for masked/inverted
|
|
alarms."
|
|
::= { statAgnGen 17 }
|
|
|
|
agnSSanityCheckStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
fail (2),
|
|
warning (3),
|
|
ok (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Upon completion of the Sanity check process on the TmpCnfg
|
|
this attribute will be set to:
|
|
FAIL(2) - when there is at least one error encountered and
|
|
possibly some warnings.
|
|
WARNING(3) - when there are only warnings.
|
|
otherwise, the value will be OK(4).
|
|
The value will be UNKNOWN(1) if changes were made in the
|
|
TmpCnfg following the last Sanity check."
|
|
::= { statAgnGen 18 }
|
|
|
|
agnSNoOfSanityCheckErr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the number of errors/warnings discovered
|
|
by the last SanityCheck process."
|
|
::= { statAgnGen 19 }
|
|
|
|
agnSErrListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnSErrListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of errors and warnings found during Sanity Check
|
|
process."
|
|
::= { statAgnGen 20 }
|
|
|
|
agnSErrListEntry OBJECT-TYPE
|
|
SYNTAX AgnSErrListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { agnSErrIdx}
|
|
::= { agnSErrListTable 1}
|
|
|
|
AgnSErrListEntry ::=
|
|
SEQUENCE {
|
|
agnSErrIdx Integer32,
|
|
agnSErrDescription DisplayString
|
|
}
|
|
|
|
agnSErrIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique number to identify an entry in the error list table.
|
|
The maximum entry value cannot exceed the value of
|
|
'agnSNoOfSanityCheckErr'. "
|
|
::= { agnSErrListEntry 1}
|
|
|
|
agnSErrDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is a full text description of the sanity check
|
|
error including error code, slot and port numbers related to
|
|
the code ."
|
|
::= { agnSErrListEntry 2}
|
|
|
|
agnSMaxNoOfCnfg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum number of configurations that can be defined and
|
|
stored in the MUX.
|
|
If the mux has a large capacity, the maximum will be limited
|
|
to 254."
|
|
::= { statAgnGen 21}
|
|
-- return 1 (db1) in phase I
|
|
|
|
agnSCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnSCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains an entry per configuration. It indicates
|
|
if the configuration is valid."
|
|
::= { statAgnGen 22 }
|
|
-- - in phase I only one entry
|
|
|
|
agnSCnfgEntry OBJECT-TYPE
|
|
SYNTAX AgnSCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { agnSEntryIdx}
|
|
::= {agnSCnfgTable 1}
|
|
|
|
AgnSCnfgEntry ::=
|
|
SEQUENCE {
|
|
agnSEntryIdx Integer32,
|
|
agnSEntryIsValid INTEGER
|
|
}
|
|
|
|
agnSEntryIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique number to identify an entry in the configuration table."
|
|
::= { agnSCnfgEntry 1}
|
|
|
|
agnSEntryIsValid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the specific configuration
|
|
is valid in the MUX . Value of NO indicates: no such
|
|
configuration in the MUX. "
|
|
::= { agnSCnfgEntry 2}
|
|
|
|
--
|
|
-- Wan agent configuration information
|
|
--
|
|
agnCSanityCheckCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to on(3) will initiate the process
|
|
of Sanity check on the TmpCnfg. Upon completion the value
|
|
will automatically be changed to off(2)."
|
|
::= { cnfgAgnGen 1 }
|
|
|
|
agnCSaveCnfgIdxCmd OBJECT-TYPE
|
|
SYNTAX Integer32 (1..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute specifies the Id of the target RealCnfg to
|
|
which the TmpCnfg should be transferred. Upon set command the
|
|
MUX will initiate the Sanity-Check process first. If
|
|
successful, the actual transfer will be performed. If warnings
|
|
are detected, the user will have to perform the command again
|
|
to confirm the operation. Setting this object a second time
|
|
to the same value without performing any change in the database,
|
|
will cause the result: agnSSanityCheckStatus = unknown"
|
|
::= { cnfgAgnGen 2 }
|
|
-- In phase I only the value 1 (Cnfg1) is valid.
|
|
|
|
agnCLoadCnfgIdxCmd OBJECT-TYPE
|
|
SYNTAX Integer32 (1..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute specifies the Id of the source Cnfg to be
|
|
loaded into the TmpCnfg. Upon set operation the actual
|
|
transfer will be initiated.
|
|
The operation is valid only on Valid configurations
|
|
(agnSEntryIsValid)"
|
|
::= { cnfgAgnGen 3 }
|
|
-- In phase I only the value 1 (Cnfg1) is valid.
|
|
|
|
|
|
agnCClkSrcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnCClkSrcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All the entries of this table are identical (have the same
|
|
value) for all the configurations (1..100) except the
|
|
TmpCnfg.
|
|
The write operation into the Table Objects is valid only
|
|
for the TmpCnfg entry."
|
|
::= { cnfgAgnGen 4}
|
|
|
|
agnCClkSrcEntry OBJECT-TYPE
|
|
SYNTAX AgnCClkSrcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnCClkCnfgIdx, agnCClkSrcIdx}
|
|
::= { agnCClkSrcTable 1}
|
|
|
|
AgnCClkSrcEntry ::=
|
|
SEQUENCE {
|
|
agnCClkCnfgIdx Integer32,
|
|
agnCClkSrcIdx Integer32,
|
|
agnCClkSrcMode INTEGER,
|
|
agnCClkSrcSlt INTEGER,
|
|
agnCClkSrcPrt Integer32
|
|
}
|
|
|
|
agnCClkCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg(1..100) being
|
|
accessed and Idx 255 relates to the TmpCnfg."
|
|
::= { agnCClkSrcEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
agnCClkSrcIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index to the table. There are only two entries to this
|
|
table.
|
|
Index 1 points to the Master clock parameters and Index 2
|
|
points to the Fallback clock parameters"
|
|
::= { agnCClkSrcEntry 2}
|
|
|
|
agnCClkSrcMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
internal (1),
|
|
rxClk (2),
|
|
adaptive (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source of the nodal timing."
|
|
::= { agnCClkSrcEntry 3}
|
|
|
|
agnCClkSrcSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry is valid only when we are working in rxClk mode.
|
|
For an invalid entry, the return value will be '7fff'h."
|
|
::= { agnCClkSrcEntry 4}
|
|
|
|
agnCClkSrcPrt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry is valid only when we are working in rxClk or
|
|
adaptive mode.
|
|
For an invalid entry, the return value will be '7fff'h.
|
|
- For rxClk mode, the values can be:
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
exPrt11 (11) ,
|
|
exPrt12 (12) ,
|
|
notApplicable (100),
|
|
inPrt1 (101) ,
|
|
inPrt2 (102) ,
|
|
inPrt3 (103) ,
|
|
inPrt4 (104)
|
|
- For adaptive mode, the value will be the ifIndex of the
|
|
selected IP Bundle."
|
|
::= { agnCClkSrcEntry 5}
|
|
|
|
agnCDeleteCnfgIdxCmd OBJECT-TYPE
|
|
SYNTAX Integer32 (1..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute will delete the requested DB
|
|
from the NVRAM ."
|
|
::= { cnfgAgnGen 5 }
|
|
|
|
agnCDefaultCnfgIdxCmd OBJECT-TYPE
|
|
SYNTAX Integer32 (1..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute will define the desired working
|
|
configuration when no conditions of the Flip DB Table are
|
|
fulfilled and no Net GO command was issued. This command
|
|
will be accepted only if the Configuration number exists
|
|
(agnSEntryIsValid=yes)."
|
|
::= { cnfgAgnGen 6 }
|
|
|
|
agnCnfgDataTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnCnfgDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains data about the agent configurations.
|
|
The table will support only data about valid configurations
|
|
of the agent."
|
|
::= { cnfgAgnGen 7}
|
|
|
|
agnCnfgDataEntry OBJECT-TYPE
|
|
SYNTAX AgnCnfgDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnCnfgIdx}
|
|
::= { agnCnfgDataTable 1}
|
|
|
|
AgnCnfgDataEntry ::=
|
|
SEQUENCE {
|
|
agnCnfgIdx Integer32,
|
|
agnCnfgDesc DisplayString,
|
|
agnCnfgUpdDate DisplayString,
|
|
agnCnfgUpdTime DisplayString,
|
|
agnCnfgUpdMnger IpAddress
|
|
}
|
|
|
|
agnCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the agent' Cnfg the following
|
|
objects refer.
|
|
255=Temporary Cnfg (Set is done only to this configuration)."
|
|
::= { agnCnfgDataEntry 1}
|
|
-- Only the values 1..10, 255 are valid.
|
|
|
|
agnCnfgDesc OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..30))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a description of the Configuration, entered
|
|
by user, to enhance Cnfg recognition."
|
|
::= { agnCnfgDataEntry 2}
|
|
|
|
agnCnfgUpdDate OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the date when last update of this
|
|
configuration was performed, as it is known by the
|
|
agent using its own real-time clock. The format would be as
|
|
specified by the agnSDateFormat.
|
|
When update is performed, the agent should save the date."
|
|
::= { agnCnfgDataEntry 3 }
|
|
|
|
agnCnfgUpdTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the time when last update of this
|
|
configuration was performed, as it is known by the
|
|
agent using its own real-time clock.
|
|
When update is performed, the agent should save the time."
|
|
::= { agnCnfgDataEntry 4 }
|
|
|
|
agnCnfgUpdMnger OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the IP Address of the Manager who
|
|
performed the last update of this configuration.
|
|
When update is performed, the agent should save the
|
|
IP Address of the Manager who commanded the update.
|
|
That will enable a manager to know if he performed the last
|
|
update, or another manager did."
|
|
::= { agnCnfgDataEntry 5 }
|
|
|
|
|
|
agnCnfgAlarm OBJECT IDENTIFIER ::= { cnfgAgnGen 8}
|
|
|
|
agnCnfgAlrFilterWindow OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Window of time, in seconds.
|
|
During this Window, the alarms filter is performed.
|
|
Same Window for all agent alarms that need filtering.
|
|
Upon end of the Window, the state of the alarm is updated
|
|
and a new Window starts.
|
|
If no alarm needs filtering, this object's value will not be
|
|
used."
|
|
::= { agnCnfgAlarm 1}
|
|
|
|
agnCnfgAlrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnCnfgAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table enables the user to set attributes to each alarm.
|
|
Setting for a non-existing entry agnCnfgAlrMask,
|
|
agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave
|
|
for Mask) will add this new entry to the table.
|
|
Setting for an existing entry agnCnfgAlrMask/
|
|
agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no'
|
|
(noAndSave for Mask) so that ALL these objects' values are
|
|
'no' , will delete this entry from the table.
|
|
For agnCnfgAlrMask, only if [(last saved value=noAndSave)
|
|
AND (new value is 'no' or 'noAndSave')] the object's value
|
|
is considered 'no' for deleting the entry.
|
|
|
|
For some products (like MP, MPH, Vmux2100) the Active Alarms are always
|
|
part of the table and cannot be removed even if their Mask/Invert/Filter
|
|
are No."
|
|
::= { agnCnfgAlarm 2}
|
|
|
|
agnCnfgAlrEntry OBJECT-TYPE
|
|
SYNTAX AgnCnfgAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnCnfgAlrCode, agnCnfgAlrSlot, agnCnfgAlrPort}
|
|
::= { agnCnfgAlrTable 1}
|
|
|
|
AgnCnfgAlrEntry ::=
|
|
SEQUENCE {
|
|
agnCnfgAlrCode Integer32,
|
|
agnCnfgAlrSlot INTEGER,
|
|
agnCnfgAlrPort Integer32,
|
|
agnCnfgAlrMask INTEGER,
|
|
agnCnfgAlrInvert INTEGER,
|
|
agnCnfgAlrFilter INTEGER,
|
|
agnCnfgAlrFilterSet Integer32,
|
|
agnCnfgAlrFilterReset Integer32,
|
|
agnCnfgAlrSeverity INTEGER
|
|
|
|
}
|
|
|
|
agnCnfgAlrCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alarm code. The following attributes refer this code."
|
|
::= { agnCnfgAlrEntry 1 }
|
|
|
|
agnCnfgAlrSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
psA (1),
|
|
psB (2),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
all (200),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alarm slot. The following attributes apply for the alarm
|
|
code and slot selected.
|
|
all = the attributes apply to all slots.
|
|
notApplicable = the selected alarm is for system level.
|
|
For the Vmux2100 Main Board clA (3) is used."
|
|
::= { agnCnfgAlrEntry 2 }
|
|
|
|
agnCnfgAlrPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alarm port. The following attributes apply for the alarm
|
|
code,slot and port selected.
|
|
200 = all = the attributes apply to all ports of the selected slot.
|
|
When selected Slot is 'all', only 'all' or 'notApplicable' are valid
|
|
Port selections.
|
|
notApplicable = the selected alarm is for system or card
|
|
level.
|
|
=255 for MP
|
|
=100 for DXC
|
|
- For MP:
|
|
- valid cards' ports are: exPrt1(1)..exPrt16(16)
|
|
inPrt1(101)..inPrt48 (148)
|
|
- IP Bundles
|
|
- For DXC, the port index will include the Slot, as for all DXC
|
|
tables: [(IO Slot+10)&n] ; n=odd for external ports
|
|
n=even for internal ports."
|
|
::= { agnCnfgAlrEntry 3 }
|
|
|
|
agnCnfgAlrMask OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (1),
|
|
noAndSave (2),
|
|
yes (3),
|
|
yesAndSave (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An attribute defining the desired Mask state of an alarm .
|
|
no - unmask (this command is not saved in agent's common
|
|
database)
|
|
noAndSave - unmask ; this command is saved in agent's
|
|
common database
|
|
yes - mask (this command is not saved in agent's
|
|
common database)
|
|
yesAndSave - mask ; this command is saved in
|
|
agent's common database.
|
|
Commands that are not saved, will be lost upon power-up or
|
|
selected card removal. "
|
|
::= { agnCnfgAlrEntry 4 }
|
|
|
|
agnCnfgAlrInvert OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An attribute defining the desired Invert state of an alarm .
|
|
no - not inverted.
|
|
yes - inverted. For MP, it is not applicable for alarms
|
|
that are currently OFF."
|
|
::= { agnCnfgAlrEntry 5 }
|
|
|
|
agnCnfgAlrFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An attribute defining if Filter is desired for the alarm .
|
|
no - no filter.
|
|
yes - filter activate.
|
|
|
|
This filter is activated within a window of time defined by
|
|
agnCnfgAlrFilterWindow.
|
|
Its purpose is to avoid frequent changes of an alarm between
|
|
ON/OFF states."
|
|
::= { agnCnfgAlrEntry 6 }
|
|
|
|
agnCnfgAlrFilterSet OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a top threshold causing the alarm that passes it,
|
|
to be declared Set (ON) at the end of the respective
|
|
window of time.
|
|
- For alarms defined by default as state alarms (minor,major)
|
|
this value will be in [%].
|
|
- For alarms defined by default as events, this value will be
|
|
an integer meaning how many times this event should appear
|
|
at least, during the window in order to be considered ON.
|
|
The maximum value will be 255.
|
|
This value should be greater than the one of
|
|
agnCnfgAlrFilterReset.
|
|
Agents that do not support Alarms Filter, will return 0."
|
|
::= { agnCnfgAlrEntry 7 }
|
|
|
|
agnCnfgAlrFilterReset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a bottom threshold causing the alarm that does not
|
|
pass it, to be declared Reset (ON) at the end of the
|
|
respective window of time.
|
|
- For alarms defined by default as state alarms (minor,major)
|
|
this value will be in [%].
|
|
- For alarms defined by default as events, this value will be
|
|
an integer meaning how many times this event should appear
|
|
at most, during the window, in order to be considered OFF.
|
|
This value should be less than the one of
|
|
agnCnfgAlrFilterSet.
|
|
Agents that do not support Alarms Filter, will return 0."
|
|
::= { agnCnfgAlrEntry 8 }
|
|
|
|
|
|
agnCnfgAlrSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An attribute defining desired severity of an alarm code
|
|
per slot/port "
|
|
::= { agnCnfgAlrEntry 9 }
|
|
|
|
|
|
agnCnfgAlrReportTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnCnfgAlrReportEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table enables the user to configure the desired Alarm
|
|
Reports according to alarms severity."
|
|
::= { agnCnfgAlarm 3}
|
|
|
|
agnCnfgAlrReportEntry OBJECT-TYPE
|
|
SYNTAX AgnCnfgAlrReportEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnCnfgAlrReportType}
|
|
::= { agnCnfgAlrReportTable 1}
|
|
|
|
AgnCnfgAlrReportEntry ::=
|
|
SEQUENCE {
|
|
agnCnfgAlrReportType INTEGER,
|
|
agnCnfgAlrStartReportOn INTEGER,
|
|
agnCnfgAlrStartReportOff INTEGER
|
|
}
|
|
|
|
agnCnfgAlrReportType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
trap (1),
|
|
buffer (2),
|
|
relay (3), --Relay 1 = R1
|
|
alrLedOn (4), --Minor LED
|
|
alrLedBlink (5), --Major LED
|
|
relay2 (6) --Relay 2 = R2
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alarm report type.
|
|
trap - traps will be sent only for alarms having the
|
|
selected On/Off severity or higher.
|
|
buffer - only alarms having the selected On/Off severity and
|
|
higher, will be reported to the buffer.
|
|
relay - relay contact will be activated only for alarms
|
|
having the selected On severity or higher.
|
|
For products having 2 relays, this is the R1 Relay.
|
|
|
|
alrLedOn/alrLedBlink - user should select a higher severity
|
|
(ReportOn) for alrLedBlink than for alrLedOn
|
|
(Blinking Led means a more severe alarm than steady
|
|
ON Led).
|
|
alrLedOn - MTCL-1 Alarm Led will be ON only when
|
|
agnSAlrStatusAll equals the selected severity or
|
|
higher, but lower severity than that selected for
|
|
'alrLedBlink'.
|
|
For products having 2 LEDs, this is the Minor LED.
|
|
alrLedBlink - MTCL-1 Alarm Led will Blink only when
|
|
agnSAlrStatusAll equals the selected severity or
|
|
higher.
|
|
For products having 2 LEDs, this is the Major LED.
|
|
relay2 - relay 2 contact will be activated only for alarms
|
|
having the selected On severity or higher.
|
|
This is the R2 Relay."
|
|
::= { agnCnfgAlrReportEntry 1 }
|
|
|
|
agnCnfgAlrStartReportOn OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noReport (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the severity from which alarms will
|
|
be reported. Alarms having this severity or higher, will be
|
|
reported.
|
|
This object specifies the report severity only for alarms
|
|
that turn to ON state.
|
|
noReport - no Report at all (for any severity)."
|
|
::= { agnCnfgAlrReportEntry 2 }
|
|
|
|
agnCnfgAlrStartReportOff OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
noReport (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the severity from which alarms will
|
|
be reported. Alarms having this severity or higher, will be
|
|
reported.
|
|
This object specifies the report severity only for alarms
|
|
that turn to OFF state.
|
|
notApplicable - for 'relay','alrLedOn','alrLedBlink', 'relay2' report
|
|
types, in MP.
|
|
noReport - no Report at all (for any severity)."
|
|
::= { agnCnfgAlrReportEntry 3 }
|
|
|
|
agnCOffsetCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
normal (2),
|
|
u1 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An object defining special user request.
|
|
notApplicable - is RO value for products that do not support this object.
|
|
normal - nothing special
|
|
u1 - user 1 - for all Voice cards, the DISPLAYED Tx and Rx Levels
|
|
will have the following Offsets:
|
|
- 2 Wires port: Tx Level: the base value (for 0dBm) = 0
|
|
Rx Level: the base value (for 0dBm) = -2
|
|
- 4 Wires port: Tx Level: the base value (for 0dBm) = -16
|
|
Rx Level: the base value (for 0dBm) = 7
|
|
The MIB and application DB will use the values without Offset."
|
|
::= { cnfgAgnGen 9 }
|
|
|
|
|
|
--System T1/E1 Ring Table
|
|
--
|
|
--This table contains all ML ports that participate in a T1/E1 Ring,
|
|
--and their ML port pair.
|
|
--The table indexes are Cnfg and the Primary card & port
|
|
|
|
agnCT1E1RingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnCT1E1RingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration of all T1/E1 Ring ML cards and ports.
|
|
The write operation into the table objects is valid only
|
|
for the TmpCnfg.
|
|
A Slot/Port that does not participate in the T1/E1 Ring,
|
|
will not exist in this table.
|
|
A ML port that exists in this table, cannot exist at the same
|
|
time in the IO Redundancy table (sysCRdnTable)."
|
|
::= { cnfgAgnGen 10 }
|
|
|
|
agnCT1E1RingEntry OBJECT-TYPE
|
|
SYNTAX AgnCT1E1RingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Entry in table agnCT1E1RingTable"
|
|
INDEX { agnCT1E1RingCnfgIdx, agnCT1E1RingPrimeSlot, agnCT1E1RingPrimePort}
|
|
::= { agnCT1E1RingTable 1}
|
|
|
|
AgnCT1E1RingEntry ::=
|
|
SEQUENCE {
|
|
agnCT1E1RingCnfgIdx Integer32,
|
|
agnCT1E1RingPrimeSlot INTEGER,
|
|
agnCT1E1RingPrimePort Integer32,
|
|
agnCT1E1RingSecSlot INTEGER,
|
|
agnCT1E1RingSecPort Integer32,
|
|
agnCT1E1RingRecTime Integer32,
|
|
agnCT1E1RingRowStatus RowStatus,
|
|
agnCT1E1RingWTR Unsigned32,
|
|
agnCT1E1RingDualFailDetection INTEGER
|
|
}
|
|
|
|
agnCT1E1RingCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Cnfg(1..255) being
|
|
accessed ; Idx of 255 relates to the TmpCnfg."
|
|
::= { agnCT1E1RingEntry 1 }
|
|
|
|
agnCT1E1RingPrimeSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot number of the Primary card of the Ring Pair."
|
|
::= { agnCT1E1RingEntry 2 }
|
|
|
|
agnCT1E1RingPrimePort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number in the Primary Card.
|
|
For external ports, the value will be as that of the port in the
|
|
card. Example: external-3 -> 3
|
|
external-4 -> 4
|
|
For internal ports, the value will be 100 + the port in the
|
|
card. Example: internal-1 -> 101
|
|
internal-4 -> 104 "
|
|
::= { agnCT1E1RingEntry 3 }
|
|
|
|
agnCT1E1RingSecSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot number of the Secondary card of the Ring Pair."
|
|
::= { agnCT1E1RingEntry 4 }
|
|
|
|
agnCT1E1RingSecPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number in the Secondary Card.
|
|
For external ports, the value will be as that of the port in the
|
|
card. Example: external-3 -> 3
|
|
external-4 -> 4
|
|
For internal ports, the value will be 100 + the port in the
|
|
card. Example: internal-1 -> 101
|
|
internal-4 -> 104 "
|
|
::= { agnCT1E1RingEntry 5 }
|
|
|
|
agnCT1E1RingRecTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"T1/E1 Ring Recovery Time (sec).
|
|
Valid Values: 1..99, 65535.
|
|
65535=NA."
|
|
::= { agnCT1E1RingEntry 6 }
|
|
|
|
agnCT1E1RingRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter allows NMS to create/delete entries of this table.
|
|
The only possible supported RowStatus vaules are
|
|
active (1) and destroy (6)."
|
|
::= { agnCT1E1RingEntry 7 }
|
|
|
|
agnCT1E1RingWTR OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"T1/E1 Ring Wait to Restore (sec).
|
|
Valid Values: 0..999, 65535.
|
|
65535=NA.
|
|
When the value <> 65535, the value of agnCT1E1RingRecTime must be 65535."
|
|
::= { agnCT1E1RingEntry 8 }
|
|
|
|
agnCT1E1RingDualFailDetection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"T1/E1 Ring - Dual Failure Detection enable/disable."
|
|
::= { agnCT1E1RingEntry 9 }
|
|
|
|
|
|
agnCMainExitPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
eth (2),
|
|
e1T1SerialLink (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An object defining the Main Exit Port for the Data of the device.
|
|
In the Vmux-120 Device the Data can Exit via one of the 2 existing ports:
|
|
1. Ethernet port (2)
|
|
2. A port that can be E1 or T1 or a Serial Link (3)."
|
|
::= { cnfgAgnGen 11 }
|
|
|
|
-- Backup Configuration Table for Main Link Module
|
|
|
|
agnCBuMlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnCBuMlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration for Primary, Secondary and Third Link.
|
|
These are used for Link Backup."
|
|
::= { cnfgAgnGen 12 }
|
|
|
|
agnCBuMlEntry OBJECT-TYPE
|
|
SYNTAX AgnCBuMlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Entry in table agnCBuMlTable"
|
|
INDEX { agnCBuMlCnfgIdx, agnCBuMlRole}
|
|
::= { agnCBuMlTable 1}
|
|
|
|
AgnCBuMlEntry ::=
|
|
SEQUENCE {
|
|
agnCBuMlCnfgIdx Integer32,
|
|
agnCBuMlRole INTEGER,
|
|
agnCBuMlType INTEGER,
|
|
agnCBuMlDefaultGateway IpAddress,
|
|
agnCBuMlSubnetMask IpAddress,
|
|
agnCBuMlOamFrequency Integer32,
|
|
agnCBuMlOamTimeoutCycles Integer32,
|
|
agnCBuMlWaitToRestore Unsigned32,
|
|
agnCBuMlBfdSessionNum Unsigned32
|
|
}
|
|
|
|
agnCBuMlCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Index of the Configuration database (1..255) being
|
|
accessed. Index of 255 relates to the Temporary Configuration."
|
|
::= { agnCBuMlEntry 1 }
|
|
|
|
agnCBuMlRole OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
primary (2),
|
|
secondary (3),
|
|
third (4),
|
|
fourth (5)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Role of the Link. Primary Link is the Link that should usually work.
|
|
If the Primary Link fails, the data will go through the Secondary Link.
|
|
If both Primary and Secondary Links fail, the data will go through the Third
|
|
Link, provided it is up."
|
|
::= { agnCBuMlEntry 2 }
|
|
|
|
agnCBuMlType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (2),
|
|
e1T1a (3),
|
|
e1T1b (4),
|
|
eth (5),
|
|
ethNetUser (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Type of the Link.
|
|
For E1/T1 the Link can be Link A - e1T1a or Link B - e1T1b.
|
|
For ETH-NET, eth (5) can be used.
|
|
For ETH-NET/USER ethNetUser (6) can be used."
|
|
::= { agnCBuMlEntry 3 }
|
|
|
|
agnCBuMlDefaultGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default Gateway's IP Address."
|
|
::= { agnCBuMlEntry 4 }
|
|
|
|
agnCBuMlSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Link subnet mask."
|
|
::= { agnCBuMlEntry 5 }
|
|
|
|
agnCBuMlOamFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time in sec. between 2 OAM packets."
|
|
::= { agnCBuMlEntry 6 }
|
|
|
|
agnCBuMlOamTimeoutCycles OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No. of cycles the Link will send OAM packets without receiving a response
|
|
from the remote Link before switching to the Backup Link."
|
|
::= { agnCBuMlEntry 7 }
|
|
|
|
agnCBuMlWaitToRestore OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines traffic recovery time (in milliseconds)
|
|
of the link after its recovery.
|
|
This object is applicable only when Recovery Mode is revertive."
|
|
::= { agnCBuMlEntry 8 }
|
|
|
|
agnCBuMlBfdSessionNum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the BFD (Bidirectional Forwarding Detection) session number of the link.
|
|
When no session exists or when N/A, the value will be 0."
|
|
::= { agnCBuMlEntry 9 }
|
|
|
|
|
|
agnCQ50Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnCQ50Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table for the device Q50 parameters.
|
|
Q50 is a Signaling protocol used between PBX devices.
|
|
It is possible to control the initiation of calls using Q.50.
|
|
This is useful for devices when there is a congestion."
|
|
::= { cnfgAgnGen 13 }
|
|
|
|
agnCQ50Entry OBJECT-TYPE
|
|
SYNTAX AgnCQ50Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An Entry in table agnCQ50Table"
|
|
INDEX { agnCQ50CnfgIdx}
|
|
::= { agnCQ50Table 1}
|
|
|
|
AgnCQ50Entry ::=
|
|
SEQUENCE {
|
|
agnCQ50CnfgIdx Integer32,
|
|
agnCQ50StopCallsThresh Integer32,
|
|
agnCQ50DiscardPktThresh Integer32,
|
|
agnCQ50BlockNewModemVbdCallsThresh Integer32,
|
|
agnCQ50BlockNewModemRelayCallsThresh Integer32
|
|
}
|
|
|
|
agnCQ50CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Index of the Configuration database (1..255) being
|
|
accessed. Index of 255 relates to the Temporary Configuration."
|
|
::= { agnCQ50Entry 1 }
|
|
|
|
agnCQ50StopCallsThresh OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Bandwidth Threshold percent (%) above which
|
|
new Calls from the PBX will be disabled."
|
|
::= { agnCQ50Entry 2 }
|
|
|
|
agnCQ50DiscardPktThresh OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Bandwidth Threshold percent (%) above which
|
|
voice packets will be discarded. Usually, the value selected should be higher
|
|
than the value of agnCQ50StopCallsThresh."
|
|
::= { agnCQ50Entry 3 }
|
|
|
|
agnCQ50BlockNewModemVbdCallsThresh OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Modem VBD Calls Threshold percent (%) above which
|
|
new modem calls will be rejected."
|
|
::= { agnCQ50Entry 4 }
|
|
|
|
agnCQ50BlockNewModemRelayCallsThresh OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Modem Relay Calls Threshold percent (%) above which
|
|
new modem calls will be rejected."
|
|
::= { agnCQ50Entry 5 }
|
|
|
|
|
|
--
|
|
-- Compressed information.
|
|
--
|
|
-- Specially for RadView management station
|
|
--
|
|
agnCmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { cmprAgnGen 1 }
|
|
|
|
agnCmprEntry OBJECT-TYPE
|
|
SYNTAX AgnCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { agnCmprTypIdx, agnCmprCnfgIdx ,agnCmprVersion}
|
|
::= {agnCmprTable 1}
|
|
|
|
AgnCmprEntry ::=
|
|
SEQUENCE {
|
|
agnCmprTypIdx Integer32,
|
|
agnCmprCnfgIdx Integer32,
|
|
agnCmprVersion Integer32,
|
|
agnCmprObj OCTET STRING
|
|
}
|
|
|
|
agnCmprTypIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Type of the Compressed being
|
|
referred."
|
|
::= { agnCmprEntry 1}
|
|
|
|
agnCmprCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the configuration to which the
|
|
Compressed information is related."
|
|
::= { agnCmprEntry 2}
|
|
|
|
agnCmprVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the version of the internal format
|
|
of the Compressed data"
|
|
::= { agnCmprEntry 3}
|
|
|
|
agnCmprObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the compressed information itself."
|
|
::= { agnCmprEntry 4}
|
|
|
|
|
|
-- Compressed Dlci table in the Agent level
|
|
-- The only way of reading this table is by the command 'GET NEXT'
|
|
|
|
agnDlciCmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnDlciCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= {cmprAgnGen 2}
|
|
|
|
agnDlciCmprEntry OBJECT-TYPE
|
|
SYNTAX AgnDlciCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnDlciCmprCnfgIdx,agnDlciCmprVersion,agnDlciCmprDlciIdx}
|
|
::= {agnDlciCmprTable 1}
|
|
|
|
AgnDlciCmprEntry ::=
|
|
SEQUENCE {
|
|
agnDlciCmprCnfgIdx Integer32,
|
|
agnDlciCmprVersion Integer32,
|
|
agnDlciCmprDlciIdx Integer32,
|
|
agnDlciCmprObj OCTET STRING
|
|
}
|
|
|
|
agnDlciCmprCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the configuration to which the
|
|
Compressed information is related."
|
|
::= { agnDlciCmprEntry 1}
|
|
|
|
agnDlciCmprVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the version of the internal format
|
|
of the Compressed data"
|
|
::= { agnDlciCmprEntry 2}
|
|
|
|
agnDlciCmprDlciIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique identifier of the Dlci,
|
|
the compressed information relates to.
|
|
The values are between 16 - 991."
|
|
::= { agnDlciCmprEntry 3}
|
|
|
|
agnDlciCmprObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the compressed information itself."
|
|
::= { agnDlciCmprEntry 4}
|
|
|
|
-- Compressed Status Alarm table at the Agent level
|
|
-- The only way of reading this table is by the command 'GET NEXT'
|
|
|
|
agnAlarmsCmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnAlarmsCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= {cmprAgnGen 3}
|
|
|
|
agnAlarmsCmprEntry OBJECT-TYPE
|
|
SYNTAX AgnAlarmsCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnAlarmsCmprVersion,agnAlarmsCmprAlarmIdx}
|
|
::= {agnAlarmsCmprTable 1}
|
|
|
|
AgnAlarmsCmprEntry ::=
|
|
SEQUENCE {
|
|
agnAlarmsCmprVersion Integer32,
|
|
agnAlarmsCmprAlarmIdx Integer32,
|
|
agnAlarmsCmprObj OCTET STRING
|
|
}
|
|
|
|
agnAlarmsCmprVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the version of the internal
|
|
format of the Compressed data"
|
|
::= { agnAlarmsCmprEntry 1}
|
|
|
|
agnAlarmsCmprAlarmIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify an entry in the alarm status table
|
|
of the agent."
|
|
::= { agnAlarmsCmprEntry 2}
|
|
|
|
agnAlarmsCmprObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the compressed information itself."
|
|
::= { agnAlarmsCmprEntry 3}
|
|
|
|
-- Compressed History Alarms buffer
|
|
-- The only way of reading this table is by the command 'GET NEXT'
|
|
|
|
agnAlrBufCmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnAlrBufCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= {cmprAgnGen 4}
|
|
|
|
agnAlrBufCmprEntry OBJECT-TYPE
|
|
SYNTAX AgnAlrBufCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnAlrBufCmprVersion,agnAlrBufCmprAlarmIdx}
|
|
::= {agnAlrBufCmprTable 1}
|
|
|
|
AgnAlrBufCmprEntry ::=
|
|
SEQUENCE {
|
|
agnAlrBufCmprVersion Integer32,
|
|
agnAlrBufCmprAlarmIdx Integer32,
|
|
agnAlrBufCmprObj OCTET STRING
|
|
}
|
|
|
|
agnAlrBufCmprVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the version of the internal format of
|
|
the Compressed data"
|
|
::= { agnAlrBufCmprEntry 1}
|
|
|
|
agnAlrBufCmprAlarmIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify an entry in the history alarms
|
|
buffer of the agent."
|
|
::= { agnAlrBufCmprEntry 2}
|
|
|
|
agnAlrBufCmprObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the compressed information itself."
|
|
::= { agnAlrBufCmprEntry 3}
|
|
|
|
|
|
-- Compressed Sanity Errors buffer
|
|
-- The only way of reading this table is by the command 'GET NEXT'
|
|
|
|
|
|
agnSCmprErrListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnSCmprErrListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { cmprAgnGen 5 }
|
|
|
|
agnSCmprErrListEntry OBJECT-TYPE
|
|
SYNTAX AgnSCmprErrListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnSCmprErrVersion,agnSCmprErrIdx}
|
|
::= { agnSCmprErrListTable 1}
|
|
|
|
AgnSCmprErrListEntry ::=
|
|
SEQUENCE {
|
|
agnSCmprErrVersion Integer32,
|
|
agnSCmprErrIdx Integer32,
|
|
agnSCmprErrObj OCTET STRING
|
|
}
|
|
|
|
agnSCmprErrVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the compressed data "
|
|
::= { agnSCmprErrListEntry 1}
|
|
|
|
agnSCmprErrIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique number to identify an entry in the errors list table.
|
|
The maximum entry value cannot exceed the value of
|
|
'agnSNoOfSanityCheckErr'. "
|
|
::= { agnSCmprErrListEntry 2}
|
|
|
|
agnSCmprErrObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is a full text description of the error,
|
|
including: error code, slot and port numbers related to the
|
|
code ."
|
|
::= { agnSCmprErrListEntry 3}
|
|
|
|
|
|
-- New TS Assignment compressed table, per port 01/09/98
|
|
-- The only way of reading this table is by the command 'GET NEXT'
|
|
|
|
agnTsCmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnTsCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { cmprAgnGen 6 }
|
|
|
|
agnTsCmprEntry OBJECT-TYPE
|
|
SYNTAX AgnTsCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { agnTsCmprVerIdx, agnTsCmprCnfgIdx , agnTsCmprSlotIdx,
|
|
agnTsCmprPortIdx, agnTsCmprPduIdx }
|
|
::= {agnTsCmprTable 1}
|
|
|
|
AgnTsCmprEntry ::=
|
|
SEQUENCE {
|
|
agnTsCmprVerIdx Integer32,
|
|
agnTsCmprCnfgIdx Integer32,
|
|
agnTsCmprSlotIdx Integer32,
|
|
agnTsCmprPortIdx Integer32,
|
|
agnTsCmprPduIdx Integer32,
|
|
agnTsCmprData OCTET STRING
|
|
}
|
|
|
|
agnTsCmprVerIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the version of the internal format
|
|
of the Compressed data."
|
|
::= { agnTsCmprEntry 1}
|
|
|
|
agnTsCmprCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the configuration to which the
|
|
Compressed information is related.
|
|
255=temporary configuration.
|
|
Set can be performed only to the temporary configuration."
|
|
::= { agnTsCmprEntry 2}
|
|
|
|
agnTsCmprSlotIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Slot to which the
|
|
Compressed information is related.
|
|
For MP-2100: IO-1..IO-12 = (5).. (16)
|
|
For DXC-30 : IO-1..IO-15 = (5).. (19).
|
|
NA=255."
|
|
::= { agnTsCmprEntry 3}
|
|
|
|
agnTsCmprPortIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Port within the Slot, to which the
|
|
Compressed information is related.
|
|
For Port Index see each product's spec."
|
|
::= { agnTsCmprEntry 4}
|
|
|
|
agnTsCmprPduIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the PDU index within the same port.
|
|
That provides for the case when one PDU is not sufficient for all TS
|
|
Assignment data of the same port."
|
|
::= { agnTsCmprEntry 5}
|
|
|
|
agnTsCmprData OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the compressed information itself. It provides
|
|
information about all TSs of a port."
|
|
::= { agnTsCmprEntry 6}
|
|
|
|
-- Extended Compress General Table with 7 indexes - 10/02/99
|
|
-- Used for: V5.1 and V5.2 Variant
|
|
|
|
agnXCmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnXCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { cmprAgnGen 7 }
|
|
|
|
agnXCmprEntry OBJECT-TYPE
|
|
SYNTAX AgnXCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnXCmprTypIdx, agnXCmprVersion, agnXCmprIdx3,agnXCmprIdx4,
|
|
agnXCmprIdx5, agnXCmprIdx6, agnXCmprIdx7}
|
|
::= {agnXCmprTable 1}
|
|
|
|
AgnXCmprEntry ::=
|
|
SEQUENCE {
|
|
agnXCmprTypIdx Integer32,
|
|
agnXCmprVersion Integer32,
|
|
agnXCmprIdx3 Integer32,
|
|
agnXCmprIdx4 Integer32,
|
|
agnXCmprIdx5 Integer32,
|
|
agnXCmprIdx6 Integer32,
|
|
agnXCmprIdx7 Integer32,
|
|
agnXCmprObj OCTET STRING
|
|
}
|
|
|
|
agnXCmprTypIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Type of the Compressed being
|
|
referred.
|
|
One of the types is V5.1 Variant data."
|
|
::= { agnXCmprEntry 1}
|
|
|
|
agnXCmprVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the version of the internal format of
|
|
the Compressed data."
|
|
::= { agnXCmprEntry 2}
|
|
|
|
agnXCmprIdx3 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"3rd index - can be used for any purpose according to the
|
|
agnXCmprTypIdx.
|
|
Example: for V5.1 Variant, this attribute indicates the configuration
|
|
to which the Compressed information is related.
|
|
255=temporary configuration.
|
|
Set can be performed only to the temporary configuration."
|
|
::= { agnXCmprEntry 3}
|
|
|
|
agnXCmprIdx4 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"4th index - can be used for any purpose according to the
|
|
agnXCmprTypIdx.
|
|
Example: for V5.1 Variant,this attribute indicates a unique number of
|
|
the slot position where the card is inserted.
|
|
Valid values: psA(1),psB(2),clA(3),clB(4),io1(5)..io12(16); notApplicable=255."
|
|
::= { agnXCmprEntry 4}
|
|
|
|
agnXCmprIdx5 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"5th index - can be used for any purpose according to the
|
|
agnXCmprTypIdx.
|
|
Example: for V5.1 Variant,this attribute indicates a unique identifier
|
|
of the port the compressed information relates to.
|
|
Valid values: exPrt1 (1) .. exPrt12 (12) ,
|
|
inPrt1 (101) .. inPrt48 (148)."
|
|
::= { agnXCmprEntry 5}
|
|
|
|
agnXCmprIdx6 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"6th index - can be used for any purpose according to the
|
|
agnXCmprTypIdx.
|
|
Example: for V5.1 Variant,this attribute indicates the Variant index.
|
|
Valid values are: 0..127, 255 (= temp cnfg).Set can be performed only
|
|
to the temporary configuration."
|
|
::= { agnXCmprEntry 6}
|
|
|
|
agnXCmprIdx7 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"7th index - can be used for any purpose according to the
|
|
agnXCmprTypIdx.
|
|
Example: for V5.1 Variant,this attribute is not needed. Therefore, its
|
|
value will be always 255=notApplicable."
|
|
::= { agnXCmprEntry 7}
|
|
|
|
agnXCmprObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the compressed information itself."
|
|
::= { agnXCmprEntry 8}
|
|
|
|
--
|
|
-- Link Mapping Table for internal use
|
|
--
|
|
agnLinkMapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnLinkMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { mapWanGen 1}
|
|
|
|
agnLinkMapEntry OBJECT-TYPE
|
|
SYNTAX AgnLinkMapEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {mapLinkId}
|
|
::= {agnLinkMapTable 1}
|
|
|
|
AgnLinkMapEntry ::=
|
|
SEQUENCE {
|
|
mapLinkId Integer32,
|
|
mapLinkSltIdx INTEGER,
|
|
mapLinkPrtIdx INTEGER,
|
|
mapLinkStatus INTEGER
|
|
}
|
|
|
|
mapLinkId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of the link"
|
|
::= {agnLinkMapEntry 1}
|
|
|
|
mapLinkSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noConnect (2),
|
|
clA (3),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries clA(3), io6(10)..io12(16) are
|
|
not valid."
|
|
::= {agnLinkMapEntry 2}
|
|
|
|
mapLinkPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
exPrt11 (11) ,
|
|
exPrt12 (12) ,
|
|
noConnect (100) ,
|
|
inPrt1 (101) ,
|
|
inPrt2 (102) ,
|
|
inPrt3 (103) ,
|
|
inPrt4 (104) ,
|
|
inPrt5 (105) ,
|
|
inPrt6 (106) ,
|
|
inPrt7 (107) ,
|
|
inPrt8 (108) ,
|
|
inPrt9 (109) ,
|
|
inPrt10 (110) ,
|
|
inPrt11 (111) ,
|
|
inPrt12 (112)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number. "
|
|
::= {agnLinkMapEntry 3}
|
|
|
|
mapLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
down(2),
|
|
up(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the status of the link between the
|
|
two muxes"
|
|
::= {agnLinkMapEntry 4}
|
|
|
|
|
|
--
|
|
-- diverseIfWanGen - diverse NON-DS1 interfaces of WAN products
|
|
--
|
|
|
|
|
|
|
|
--sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} (see radsonet.txt)
|
|
--ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} (see radds3.txt)
|
|
--ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} (see radds1.txt)
|
|
--hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} (see radhdlc.txt)
|
|
--ip2If OBJECT IDENTIFIER ::= { diverseIfWanGen 7 } (see ipmux.txt)
|
|
|
|
|
|
--
|
|
-- Wan alarm buffer (history) information
|
|
--
|
|
alrBufTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AlrBufEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { alrBuffGen 1 }
|
|
|
|
alrBufEntry OBJECT-TYPE
|
|
SYNTAX AlrBufEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { alrBufIdx }
|
|
::= { alrBufTable 1}
|
|
|
|
AlrBufEntry ::=
|
|
SEQUENCE {
|
|
alrBufIdx Integer32,
|
|
alrBufDescription DisplayString,
|
|
alrBufCode Unsigned32,
|
|
alrBufSlot INTEGER,
|
|
alrBufPort Unsigned32,
|
|
alrBufSeverity INTEGER,
|
|
alrBufState INTEGER
|
|
}
|
|
|
|
alrBufIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify this
|
|
entry"
|
|
::= { alrBufEntry 1}
|
|
|
|
alrBufDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry is a unique text description of the alarm in the
|
|
buffer.
|
|
The alarm description includes the following information:
|
|
alarm code, slot id, card type, channel id ,
|
|
alarm text, alarm status, masked flag and event counter"
|
|
::= { alrBufEntry 2}
|
|
|
|
alrBufCode OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A code identifying the alarm of an entry in the alarm buffer
|
|
table."
|
|
::= { alrBufEntry 3 }
|
|
|
|
alrBufSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
psA (1),
|
|
psB (2),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot number this alarm refers to.
|
|
When the alarm refers to a system alarm, the value will be 'notApplicable(255)'."
|
|
::= { alrBufEntry 4 }
|
|
|
|
alrBufPort OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number this alarm refers to.
|
|
If the port number is irrelevant to this alarm (if it is
|
|
a system/card level alarm) the value will be 9999."
|
|
::= { alrBufEntry 5 }
|
|
|
|
alrBufSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the alarm."
|
|
::= { alrBufEntry 6 }
|
|
|
|
alrBufState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of the alarm (On/Off)."
|
|
::= { alrBufEntry 7 }
|
|
|
|
|
|
alrBufferClearCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to ON, will enforce a clear
|
|
operation on the Alarms Buffer. Upon completion,
|
|
the value will automatically change to off(2).
|
|
For MP-2100/2200, this command will not really erase
|
|
the Alarm Buffer, but is only an ACK of seeing the Buffer.
|
|
It marks a pointer of the last entry's alrBufIdx, in order
|
|
to allow view of new alarms entered after this pointer
|
|
(alrBufIdxUponLastAck)."
|
|
::= { alrBuffGen 2 }
|
|
|
|
alrBufIdxUponLastAck OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the value of alrBufIdx for the
|
|
last existing entry of alrBufTable, when alrBufferClearCmd
|
|
was last Set to on(3).
|
|
That will enable a user to see only Alarms that entered the
|
|
alrBufTable after last Set of alrBufferClearCmd, by GetNext
|
|
of alrBufDescription with this index."
|
|
::= { alrBuffGen 3 }
|
|
|
|
--
|
|
-- Wan Flip Data-Base parameters
|
|
--
|
|
-- agnCAgendaTable :
|
|
--
|
|
|
|
agnCAgendaTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnCAgendaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table devides the week days into categories needed for
|
|
DB flip consideration."
|
|
::= {agnFlipDb 1}
|
|
|
|
agnCAgendaEntry OBJECT-TYPE
|
|
SYNTAX AgnCAgendaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnCAgendaCnfgIdx, agnCAgendaDayIdx}
|
|
::= {agnCAgendaTable 1}
|
|
|
|
AgnCAgendaEntry ::=
|
|
SEQUENCE {
|
|
agnCAgendaCnfgIdx INTEGER,
|
|
agnCAgendaDayIdx INTEGER,
|
|
agnCAgendaDayCategory INTEGER
|
|
}
|
|
|
|
agnCAgendaCnfgIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
active (1),
|
|
temporary (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active or Temporary Agenda Table.
|
|
Both configurations can be read but only the Temporary can
|
|
be written to."
|
|
::= {agnCAgendaEntry 1}
|
|
|
|
agnCAgendaDayIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
sunday (1),
|
|
monday (2),
|
|
tuesday (3),
|
|
wednesday (4),
|
|
thursday (5),
|
|
friday (6),
|
|
saturday (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Day of week"
|
|
::= {agnCAgendaEntry 2}
|
|
|
|
agnCAgendaDayCategory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fullWorkday (1),
|
|
partialWorkday (2),
|
|
weekend (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Category of the Day "
|
|
::= {agnCAgendaEntry 3}
|
|
|
|
|
|
-- agnCFlipNetEventsTable :
|
|
--
|
|
|
|
agnCFlipNetEventsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnCFlipNetEventsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table holds the Net Events the MUX should trace"
|
|
::= {agnFlipDb 2}
|
|
|
|
agnCFlipNetEventsEntry OBJECT-TYPE
|
|
SYNTAX AgnCFlipNetEventsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnCFlipNetEventsCnfgIdx, agnCFlipNetEventIdx}
|
|
::= {agnCFlipNetEventsTable 1}
|
|
|
|
AgnCFlipNetEventsEntry ::=
|
|
SEQUENCE {
|
|
agnCFlipNetEventsCnfgIdx INTEGER,
|
|
agnCFlipNetEventIdx Integer32,
|
|
agnCFlipNetEventActive INTEGER,
|
|
agnCFlipNetEventType INTEGER,
|
|
agnCFlipNetEventNo Integer32,
|
|
agnCFlipNetEventSlot INTEGER,
|
|
agnCFlipNetEventPort Integer32,
|
|
agnCFlipNetEventISD Integer32,
|
|
agnCFlipNetEventOSD Integer32,
|
|
agnCFlipNetEventDayType INTEGER,
|
|
agnCFlipNetEventStartTime DisplayString,
|
|
agnCFlipNetEventEndTime DisplayString
|
|
}
|
|
|
|
agnCFlipNetEventsCnfgIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
active (1),
|
|
temporary (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active or Temporary Net Events Table.
|
|
Both configurations can be read but only the Temporary can
|
|
be written to."
|
|
::= {agnCFlipNetEventsEntry 1}
|
|
|
|
agnCFlipNetEventIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry within the table"
|
|
::= {agnCFlipNetEventsEntry 2}
|
|
|
|
agnCFlipNetEventActive OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the entry is valid.
|
|
In order to Add/Modify parameters of an entry, this object
|
|
should be set to Yes.
|
|
In order to delete an entry, this object should be Set to No."
|
|
::= {agnCFlipNetEventsEntry 3}
|
|
|
|
|
|
agnCFlipNetEventType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
time (1),
|
|
linkDown (2),
|
|
congestion (3) -- MP3000 Only
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Net Event type "
|
|
::= {agnCFlipNetEventsEntry 4}
|
|
|
|
agnCFlipNetEventNo OBJECT-TYPE
|
|
SYNTAX Integer32 (1..512)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Net Event No. (Bit Index)"
|
|
::= {agnCFlipNetEventsEntry 5}
|
|
|
|
agnCFlipNetEventSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot to which the net event relates .
|
|
Not applicable for time event"
|
|
::= {agnCFlipNetEventsEntry 6}
|
|
|
|
agnCFlipNetEventPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port within the relevant slot.
|
|
Valid values:
|
|
- extPrt1(1)..exPrt16(16)
|
|
- notApplicable(100)
|
|
- inPrt1(101)..inPrt84(184)"
|
|
::= {agnCFlipNetEventsEntry 7}
|
|
|
|
agnCFlipNetEventISD OBJECT-TYPE
|
|
SYNTAX Integer32 (1..999)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time in seconds since the Net Event was reported as ON
|
|
until it is considered as ON.
|
|
Not relevant for time events."
|
|
::= {agnCFlipNetEventsEntry 8}
|
|
|
|
agnCFlipNetEventOSD OBJECT-TYPE
|
|
SYNTAX Integer32 (1..999)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time in seconds since the net event was reported as OFF
|
|
until it is considered as OFF.
|
|
Not relevant for time events."
|
|
::= {agnCFlipNetEventsEntry 9}
|
|
|
|
agnCFlipNetEventDayType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
fullWorkday (2),
|
|
partialWorkday (3),
|
|
weekend (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time event relates to all days defined in this category in
|
|
the agnCAgendaTable.
|
|
Applicable only for time event"
|
|
::= {agnCFlipNetEventsEntry 10}
|
|
|
|
agnCFlipNetEventStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (5))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time event will be activated at this time.
|
|
The format is hh:mm."
|
|
::= {agnCFlipNetEventsEntry 11}
|
|
|
|
agnCFlipNetEventEndTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (5))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time event will be deactivated at this time.
|
|
The format is hh:mm."
|
|
::= {agnCFlipNetEventsEntry 12}
|
|
|
|
|
|
-- agnCFlipTable :
|
|
--
|
|
|
|
agnCFlipTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnCFlipEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DB Flip Decisions Table"
|
|
::= {agnFlipDb 3}
|
|
|
|
agnCFlipEntry OBJECT-TYPE
|
|
SYNTAX AgnCFlipEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnCFlipCnfgIdx, agnCFlipIdx}
|
|
::= {agnCFlipTable 1}
|
|
|
|
AgnCFlipEntry ::=
|
|
SEQUENCE {
|
|
agnCFlipCnfgIdx INTEGER,
|
|
agnCFlipIdx Integer32,
|
|
agnCFlipActive INTEGER,
|
|
agnCFlipLogicalExp DisplayString,
|
|
agnCFlipDbNo Integer32,
|
|
agnCFlipDiscardDe INTEGER
|
|
}
|
|
|
|
agnCFlipCnfgIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
active (1),
|
|
temporary (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active or Temporary Flip Decisions Table.
|
|
Both configurations can be read but only the Temporary can
|
|
be written to."
|
|
::= {agnCFlipEntry 1}
|
|
|
|
|
|
|
|
agnCFlipIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry number within the table"
|
|
::= {agnCFlipEntry 2}
|
|
|
|
agnCFlipActive OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the entry is valid.
|
|
In order to Add/Modify parameters of an entry this object
|
|
should be Set to Yes.
|
|
In order to delete an entry, this object should be Set to No."
|
|
::= {agnCFlipEntry 3}
|
|
|
|
agnCFlipLogicalExp OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A logical expression composed of events numbers (which were
|
|
configured in the 'AgnCFlipNetEvantsTable') and logical operators
|
|
('|', '&', '!', '(', ')') between them.
|
|
e.g - (1 & !2) | (121 & 230)"
|
|
::= {agnCFlipEntry 4}
|
|
|
|
agnCFlipDbNo OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ID of the required DB "
|
|
::= {agnCFlipEntry 5}
|
|
|
|
agnCFlipDiscardDe OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Mux should start discarding
|
|
all DE. (MP3000 Only)."
|
|
::= {agnCFlipEntry 6}
|
|
|
|
-- Commands concerning the Flip DB
|
|
|
|
agnFlipDbControls OBJECT IDENTIFIER ::= {agnFlipDb 4}
|
|
|
|
|
|
agnCFlipDbSanityCheckCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to on(3) will initiate the process
|
|
of Sanity check on the Temp Flip Db and automatically be
|
|
changed to off(2)."
|
|
::= { agnFlipDbControls 1 }
|
|
|
|
agnCSaveFlipDbCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to on(3) will initiate the process
|
|
of Sanity check on the Temp Flip Db and if it is OK, it will
|
|
save the Flip Db in the NVRAM, activating the new Flip DB .
|
|
If check detects errors, the save will not be performed.
|
|
Afterwards, the object's value will change automatically to off(2)."
|
|
::= { agnFlipDbControls 2 }
|
|
|
|
agnCSaveNetCnfgIdxCmd OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute specifies the Id of the target NVRAM Cnfg to
|
|
which the TmpCnfg should be transferred. Upon set command the
|
|
MUX will initiate the Sanity-Check process first. If
|
|
successful, the actual transfer will be performed. If warnings
|
|
are detected, the user will have to perform the command again
|
|
to confirm the operation. Setting this object a second time
|
|
to the same value without performing any change in the database,
|
|
will cause the result: agnSSanityCheckStatus = unknown.
|
|
This attribute doesn't cause actual Flip."
|
|
::= { agnFlipDbControls 3 }
|
|
|
|
agnCSaveNetFlipDbCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to on(3) will save the Temp Flip DB
|
|
Into the NVRAM without actual flip."
|
|
::= { agnFlipDbControls 4 }
|
|
|
|
agnCNetGoCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to On will broadcast a 'GO' command
|
|
to the network. When a Mux receives a 'GO' command it issues
|
|
a delay for 'agnCNetDelay' seconds and then activates
|
|
the DB which was pre-defined by one of the commands :
|
|
'agnCSaveNetCnfgIdxCmd' or 'agnCSaveNetFlipDbCmd'."
|
|
::= { agnFlipDbControls 5 }
|
|
|
|
agnCNetDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (1..999)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute determines the period of time in seconds that
|
|
takes for a message to be transferred over all the network.
|
|
After a 'GO' command the MUX issues a delay of
|
|
'agnCNetDelay' before activating the appropriate DB.
|
|
The delay will be applied only after performing
|
|
agnCSaveFlipDbCmd."
|
|
::= { agnFlipDbControls 6 }
|
|
|
|
agnCNetEventsBcast OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines if the Net Events will be Broadcasted to
|
|
other Muxes of the Net or not.
|
|
disabled - Net Events will NOT be Broadcasted
|
|
enabled - Net Events will be Broadcasted.
|
|
Default=disabled.
|
|
The value will be applied only after performing
|
|
agnCSaveFlipDbCmd."
|
|
::= { agnFlipDbControls 7 }
|
|
|
|
agnCNetEventsBcastInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (10..60)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When agnCNetEventsBcast is enabled, this object determines
|
|
the interval of time in seconds, between two consecutive
|
|
Net Events transferred over the network.
|
|
Default=40 sec.
|
|
The interval will be applied only after performing
|
|
agnCSaveFlipDbCmd."
|
|
::= { agnFlipDbControls 8 }
|
|
|
|
--
|
|
-- agnSa = agent Stand-Alone (not HUB) specific objects
|
|
--
|
|
agnSaSwchStatus OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of the switches on the
|
|
stand-alone unit.
|
|
Each switch is represented by a bit. The status is a sum of
|
|
2**n, according to the bits:
|
|
bit 0 NMS (LSB)
|
|
bit 1 Terminal '1' = forces the DCE to be terminal with
|
|
Rate=9600bps, Data bits=8,
|
|
Stop bits=1
|
|
bit 2 Xray
|
|
bit 3 SW-Load '1' = when SW is loaded
|
|
bit 4 DBS
|
|
Default of all bits=0
|
|
When the status of these switches is unknown, the value of
|
|
this object is 255."
|
|
::= { agnSa 1 }
|
|
|
|
--Decoding Table: Code vs. Description
|
|
|
|
agnListDecodingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnListDecodingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A decoding table . For each type of list, a description is
|
|
given for each existing code."
|
|
::= { agnListDecoding 1 }
|
|
|
|
agnListDecodingEntry OBJECT-TYPE
|
|
SYNTAX AgnListDecodingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { agnListDecodingType, agnListDecodingCode }
|
|
::= { agnListDecodingTable 1}
|
|
|
|
AgnListDecodingEntry ::=
|
|
SEQUENCE {
|
|
agnListDecodingType INTEGER,
|
|
agnListDecodingCode Integer32,
|
|
agnListDecodingDescription DisplayString,
|
|
agnListDecodingDefState INTEGER,
|
|
agnListDecodingSeverity INTEGER,
|
|
agnListDecodingAcmRelaySlt INTEGER,
|
|
agnListDecodingAcmRelayPrt INTEGER
|
|
}
|
|
|
|
agnListDecodingType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
alr (1),
|
|
sanity (2),
|
|
counter (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of list the decoding data refers to.
|
|
alr - Alarms list
|
|
sanity - Sanity Check Error list.
|
|
counter - Counter type of ifPerfCounterType "
|
|
::= { agnListDecodingEntry 1}
|
|
|
|
agnListDecodingCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The specific code for which decoding is needed. "
|
|
::= { agnListDecodingEntry 2}
|
|
|
|
agnListDecodingDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description fitting the specific code and type of list
|
|
required. "
|
|
::= { agnListDecodingEntry 3}
|
|
|
|
agnListDecodingDefState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only for agnListDecodingType=alr.
|
|
It reports the default state/severity of each alarm.
|
|
User can change the severity of the alarms defined by
|
|
this default via the agnListDecodingSeverity object."
|
|
::= { agnListDecodingEntry 4}
|
|
|
|
agnListDecodingSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only for agnListDecodingType=alr.
|
|
It enables the user to select a severity for each alarm.
|
|
The severity is set per alarm code (same for all slots/ports
|
|
using this code).
|
|
event - can be set only for an alarm that is defined by
|
|
default as 'event'.
|
|
User can change the severity of the alarms defined by
|
|
default as minor or major.
|
|
The severity of an event may be set to another severity,
|
|
but the change will actually happen only if the event
|
|
threshold is active and passed the Set/ON condition.
|
|
An event alarm that passed the threshold and changed its
|
|
severity, will return automatically to event severity when
|
|
meeting its Reset/OFF condition."
|
|
::= { agnListDecodingEntry 5}
|
|
|
|
agnListDecodingAcmRelaySlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ none (1),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the ACM slot, desired for outbound relay
|
|
(report) for the selected alarm.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
|
|
none - when agnListDecodingType=alr AND the selected
|
|
alarm should not be reported by an ACM card.
|
|
notApplicable - when agnListDecodingType=sanity OR when
|
|
[agnListDecodingType=alr and there is no ACM card installed in the Mux]."
|
|
::= { agnListDecodingEntry 6}
|
|
|
|
agnListDecodingAcmRelayPrt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the ACM port within the slot, desired for outbound relay
|
|
(report) for the selected alarm.
|
|
notApplicable - when agnListDecodingType=sanity OR when
|
|
agnListDecodingAcmRelaySlt=notApplicable."
|
|
::= { agnListDecodingEntry 7}
|
|
|
|
|
|
-- Dlci Table from system point of view
|
|
agnDlciTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnDlciEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { agnSystemDlci 1}
|
|
|
|
agnDlciEntry OBJECT-TYPE
|
|
SYNTAX AgnDlciEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnDlciCnfgIdx, agnDlciLSltIdx, agnDlciLPrtIdx, agnDlciHIdx,
|
|
agnDlciHSltIdx, agnDlciHPrtIdx, agnDlciLIdx }
|
|
::= { agnDlciTable 1}
|
|
|
|
AgnDlciEntry ::=
|
|
SEQUENCE {
|
|
agnDlciCnfgIdx Integer32,
|
|
agnDlciLSltIdx INTEGER,
|
|
agnDlciLPrtIdx Integer32,
|
|
agnDlciLIdx Integer32,
|
|
agnDlciHSltIdx INTEGER,
|
|
agnDlciHPrtIdx Integer32,
|
|
agnDlciHIdx Integer32,
|
|
agnDlciTxBc INTEGER,
|
|
agnDlciTxBe INTEGER,
|
|
agnDlciRxBc INTEGER,
|
|
agnDlciRxBe INTEGER,
|
|
agnDlciPriority Integer32,
|
|
agnDlciStatus INTEGER,
|
|
agnDlciSpoofing INTEGER,
|
|
agnDlciFunnelEnable INTEGER,
|
|
agnDlciRoutingProtocol INTEGER,
|
|
agnDlciRowStatus RowStatus
|
|
}
|
|
|
|
agnDlciCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { agnDlciEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
agnDlciLSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ cl(3),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
vs (254),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted. This is the Source Slot of the DLCI.
|
|
vs=Voice Switching
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid.
|
|
For ISDN BRI ports of MX300/30 units:
|
|
io1(5) = isdn1(5) and io2(6) = isdn2(6)
|
|
LSlotIdx is defined according one of the following possiblities:
|
|
1. LSlotIdx is < HSlotIdx.
|
|
2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
|
|
3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
|
|
::= { agnDlciEntry 2}
|
|
|
|
agnDlciLPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique external or internal port number,
|
|
including linkSelector or encapsulator. This is the Source Port of the DLCI.
|
|
100=noConnect (for voice switching)
|
|
LPrtIdx is defined according one of the following possiblities:
|
|
1. LSlotIdx is < HSlotIdx.
|
|
2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
|
|
3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
|
|
::= { agnDlciEntry 3}
|
|
|
|
agnDlciLIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (0..991)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique index for each possible
|
|
used DLCI(16..991). This is the Source Side of the DLCI.
|
|
0=notApplicable (for voice switching)
|
|
LIdx is defined according one of the following possiblities:
|
|
1. LSlotIdx is < HSlotIdx.
|
|
2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
|
|
3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
|
|
::= { agnDlciEntry 4}
|
|
|
|
agnDlciHSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ cl (3),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position In the Mux
|
|
where the DLCI is routed to - Destination Slot.
|
|
For ISDN BRI ports of MX300/30 units:
|
|
io1(5) = isdn1(5) and io2(6) = isdn2(6)
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid"
|
|
::= { agnDlciEntry 5}
|
|
|
|
agnDlciHPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number where the DLCI is
|
|
routed to - Destination Port."
|
|
::= { agnDlciEntry 6}
|
|
|
|
agnDlciHIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..991)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique internal connection DLCI
|
|
number where the Source DLCI is routed to - the Destination Side of the DLCI."
|
|
::= { agnDlciEntry 7}
|
|
|
|
agnDlciTxBc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
txBc5100bps (3),
|
|
txBc6400bps (4),
|
|
txBc8300bps (5),
|
|
txBc9600bps (6),
|
|
txBc14400bps (7),
|
|
txBc19200bps (8),
|
|
txBc28800bps (9),
|
|
txBc32000bps (10),
|
|
txBc38400bps (11),
|
|
txBc48000bps (12),
|
|
txBc56000bps (13),
|
|
txBc57600bps (14),
|
|
txBc64Kbps (15),
|
|
txBc128Kbps (16),
|
|
txBc192Kbps (17),
|
|
txBc256Kbps (18),
|
|
txBc320Kbps (19),
|
|
txBc384Kbps (20),
|
|
txBc448Kbps (21),
|
|
txBc512Kbps (22),
|
|
txBc768Kbps (23),
|
|
txBc896Kbps (24),
|
|
txBc1024Kbps (25),
|
|
txBc1152Kbps (26),
|
|
txBc1280Kbps (27),
|
|
txBc1344Kbps (28),
|
|
txBc1472Kbps (29),
|
|
txBc1600Kbps (30),
|
|
txBc1728Kbps (31),
|
|
txBc1856Kbps (32),
|
|
txBc1920Kbps (33),
|
|
txBc1984Kbps (34),
|
|
txBc2048Kbps (35),
|
|
txBc16000bps (36), -- Added here: No room between (7) and (8).
|
|
|
|
-- For Mx 30/300
|
|
txBc112Kbps (37),
|
|
txBc168Kbps (38),
|
|
txBc224Kbps (39),
|
|
txBc336Kbps (40),
|
|
txBc672Kbps (41),
|
|
txBc1536Kbps (42),
|
|
txBc1792Kbps (43)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Tx committed bandwidth on
|
|
the user transmit line or at the port receive line."
|
|
DEFVAL { full }
|
|
::= { agnDlciEntry 8}
|
|
|
|
agnDlciTxBe OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
txBe5100bps (3),
|
|
txBe6400bps (4),
|
|
txBe8300bps (5),
|
|
txBe9600bps (6),
|
|
txBe14400bps (7),
|
|
txBe19200bps (8),
|
|
txBe28800bps (9),
|
|
txBe32000bps (10),
|
|
txBe38400bps (11),
|
|
txBe48000bps (12),
|
|
txBe56000bps (13),
|
|
txBe57600bps (14),
|
|
txBe64Kbps (15),
|
|
txBe128Kbps (16),
|
|
txBe192Kbps (17),
|
|
txBe256Kbps (18),
|
|
txBe320Kbps (19),
|
|
txBe384Kbps (20),
|
|
txBe448Kbps (21),
|
|
txBe512Kbps (22),
|
|
txBe768Kbps (23),
|
|
txBe896Kbps (24),
|
|
txBe1024Kbps (25),
|
|
txBe1152Kbps (26),
|
|
txBe1280Kbps (27),
|
|
txBe1344Kbps (28),
|
|
txBe1472Kbps (29),
|
|
txBe1600Kbps (30),
|
|
txBe1728Kbps (31),
|
|
txBe1856Kbps (32),
|
|
txBe1920Kbps (33),
|
|
txBe1984Kbps (34),
|
|
txBe2048Kbps (35),
|
|
txBe16000bps (36), -- Added here: No room between (7) and (8).
|
|
|
|
-- For Mx 30/300
|
|
txBe112Kbps (37),
|
|
txBe168Kbps (38),
|
|
txBe224Kbps (39),
|
|
txBe336Kbps (40),
|
|
txBe672Kbps (41),
|
|
txBe1536Kbps (42),
|
|
txBe1792Kbps (43)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Tx excess bandwidth on the
|
|
user transmit line or at the port receive line."
|
|
DEFVAL { zero }
|
|
::= { agnDlciEntry 9}
|
|
|
|
agnDlciRxBc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
rxBc5100bps (3),
|
|
rxBc6400bps (4),
|
|
rxBc8300bps (5),
|
|
rxBc9600bps (6),
|
|
rxBc14400bps (7),
|
|
rxBc19200bps (8),
|
|
rxBc28800bps (9),
|
|
rxBc32000bps (10),
|
|
rxBc38400bps (11),
|
|
rxBc48000bps (12),
|
|
rxBc56000bps (13),
|
|
rxBc57600bps (14),
|
|
rxBc64Kbps (15),
|
|
rxBc128Kbps (16),
|
|
rxBc192Kbps (17),
|
|
rxBc256Kbps (18),
|
|
rxBc320Kbps (19),
|
|
rxBc384Kbps (20),
|
|
rxBc448Kbps (21),
|
|
rxBc512Kbps (22),
|
|
rxBc768Kbps (23),
|
|
rxBc896Kbps (24),
|
|
rxBc1024Kbps (25),
|
|
rxBc1152Kbps (26),
|
|
rxBc1280Kbps (27),
|
|
rxBc1344Kbps (28),
|
|
rxBc1472Kbps (29),
|
|
rxBc1600Kbps (30),
|
|
rxBc1728Kbps (31),
|
|
rxBc1856Kbps (32),
|
|
rxBc1920Kbps (33),
|
|
rxBc1984Kbps (34),
|
|
rxBc2048Kbps (35),
|
|
rxBc16000bps (36), -- Added here: No room between (7) and (8).
|
|
|
|
-- For Mx 30/300
|
|
rxBc112Kbps (37),
|
|
rxBc168Kbps (38),
|
|
rxBc224Kbps (39),
|
|
rxBc336Kbps (40),
|
|
rxBc672Kbps (41),
|
|
rxBc1536Kbps (42),
|
|
rxBc1792Kbps (43)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Rx committed bandwidth on
|
|
the user receive line or at the port transmit line."
|
|
DEFVAL { full }
|
|
::= { agnDlciEntry 10}
|
|
|
|
agnDlciRxBe OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
rxBe5100bps (3),
|
|
rxBe6400bps (4),
|
|
rxBe8300bps (5),
|
|
rxBe9600bps (6),
|
|
rxBe14400bps (7),
|
|
rxBe19200bps (8),
|
|
rxBe28800bps (9),
|
|
rxBe32000bps (10),
|
|
rxBe38400bps (11),
|
|
rxBe48000bps (12),
|
|
rxBe56000bps (13),
|
|
rxBe57600bps (14),
|
|
rxBe64Kbps (15),
|
|
rxBe128Kbps (16),
|
|
rxBe192Kbps (17),
|
|
rxBe256Kbps (18),
|
|
rxBe320Kbps (19),
|
|
rxBe384Kbps (20),
|
|
rxBe448Kbps (21),
|
|
rxBe512Kbps (22),
|
|
rxBe768Kbps (23),
|
|
rxBe896Kbps (24),
|
|
rxBe1024Kbps (25),
|
|
rxBe1152Kbps (26),
|
|
rxBe1280Kbps (27),
|
|
rxBe1344Kbps (28),
|
|
rxBe1472Kbps (29),
|
|
rxBe1600Kbps (30),
|
|
rxBe1728Kbps (31),
|
|
rxBe1856Kbps (32),
|
|
rxBe1920Kbps (33),
|
|
rxBe1984Kbps (34),
|
|
rxBe2048Kbps (35),
|
|
rxBe16000bps (36), -- Added here: No room between (7) and (8).
|
|
|
|
-- For Mx 30/300
|
|
rxBe112Kbps (37),
|
|
rxBe168Kbps (38),
|
|
rxBe224Kbps (39),
|
|
rxBe336Kbps (40),
|
|
rxBe672Kbps (41),
|
|
rxBe1536Kbps (42),
|
|
rxBe1792Kbps (43)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Rx excess bandwidth on the
|
|
user receive line or at the port transmit line."
|
|
DEFVAL { zero }
|
|
::= { agnDlciEntry 11}
|
|
|
|
agnDlciPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique priority of the pcv.
|
|
1 is the lowest priority and 7 is the highest priority."
|
|
::= { agnDlciEntry 12}
|
|
|
|
agnDlciStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disconnected (1),
|
|
connected (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the status of the pvc. The status is
|
|
disconnected(1) when one of the sides is programmed as
|
|
not connected"
|
|
::= { agnDlciEntry 13}
|
|
|
|
agnDlciSpoofing OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object refers to sending of RIP messages:
|
|
- yes : RIP messages will be sent ONLY if there is a change in the Net.
|
|
- no : RIP messages will be always sent.
|
|
This object is relevant only when one side of the DLCI is a CL-NMS interface.
|
|
Default=no. "
|
|
::= { agnDlciEntry 14}
|
|
|
|
agnDlciFunnelEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ disabled (2),
|
|
enabled (3),
|
|
source (4),
|
|
destination (5)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object selects Funnel activation:
|
|
|
|
- disabled: Funnel operation will be disabled.
|
|
The agnDlciTxBe and agnDlciTxBc values are not used for funneling.
|
|
- enabled : Funnel operation will be enabled both for Source and Destination
|
|
of the DLCI. The agnDlciTxBe and agnDlciTxBc values are used
|
|
for funneling calculations.
|
|
- source: Funnel operation will be enabled only for the Source of the DLCI.
|
|
- destination:Funnel operation will be enabled only for the Destination of the DLCI.
|
|
|
|
This object is relevant only for an encapsulating DLCI.
|
|
|
|
In case of a Link Selector DLCI, the agnDlciTxBe and agnDlciTxBc
|
|
values are used for bandwidth of Link Selector.
|
|
Default=disabled. "
|
|
::= { agnDlciEntry 15}
|
|
|
|
agnDlciRoutingProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ notApplicable(1),
|
|
rip (2),
|
|
rip2(3),
|
|
none(4)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is relevant only when one side of the DLCI is a CL-NMS interface.
|
|
It defines which Routing Protocol will be used for management via CL-NMS port.
|
|
notApplicable will be used for all slots but CL.
|
|
rip is a proprietary rip protocol.
|
|
|
|
Default=rip. "
|
|
::= { agnDlciEntry 16}
|
|
|
|
agnDlciRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute allows to create/delete a row in this table.
|
|
For creating a row, the NMS should set
|
|
agnRowStatus.255.id2.id3.id4.id5.id6.id7 = active(1).
|
|
For destroying a row, the NMS should set:
|
|
agnRowStatus.255.id2.id3.id4.id5.id6.id7 = destroy(6).
|
|
Only rows with status active(1) are relevant.
|
|
The only possible supported RowStatus vaules are
|
|
active (1) and destroy (6)."
|
|
::= { agnDlciEntry 17}
|
|
|
|
|
|
-- Voice Switching Configuration Support: agnVoiceSwitching group
|
|
agnVoiceSwConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnVoiceSwConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MXcess Configuration for Voice Switching."
|
|
::= { agnVoiceSwitching 1 }
|
|
|
|
agnVoiceSwConfEntry OBJECT-TYPE
|
|
SYNTAX AgnVoiceSwConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { agnVoiceSwConfIdx }
|
|
::= { agnVoiceSwConfTable 1}
|
|
|
|
AgnVoiceSwConfEntry ::=
|
|
SEQUENCE {
|
|
agnVoiceSwConfIdx INTEGER,
|
|
agnVoiceSwConfZoneId DisplayString,
|
|
agnVoiceSwConfNodeId DisplayString,
|
|
agnVoiceSwConfNoOfHops Integer32,
|
|
agnVoiceSwConfSidt Integer32,
|
|
agnVoiceSwConfLidt Integer32,
|
|
agnVoiceSwConfDialPlan INTEGER
|
|
}
|
|
|
|
agnVoiceSwConfIdx OBJECT-TYPE
|
|
SYNTAX INTEGER { active(1), temporary(255) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active or Temporary Table.
|
|
Both configurations can be read but only the Temporary can
|
|
be written to."
|
|
::= { agnVoiceSwConfEntry 1}
|
|
|
|
agnVoiceSwConfZoneId OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(1..2))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"1 or 2 digits, (0-9)(1-9)."
|
|
::= { agnVoiceSwConfEntry 2}
|
|
|
|
agnVoiceSwConfNodeId OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(1..3))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"1, 2 or 3 digits, (1-9),(0-9),(0-9)."
|
|
::= { agnVoiceSwConfEntry 3}
|
|
|
|
agnVoiceSwConfNoOfHops OBJECT-TYPE
|
|
SYNTAX Integer32 (0..20)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of hops the frame will go through the net before deciding to discard
|
|
the frame (like time-to-live in IP).
|
|
|
|
0 = notApplicable
|
|
Default=20 ."
|
|
::= { agnVoiceSwConfEntry 4}
|
|
|
|
agnVoiceSwConfSidt OBJECT-TYPE
|
|
SYNTAX Integer32 (0..30)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SIDT: Short Inter Digit Timeout used as timer (in sec.) between digits
|
|
after routing is completed.
|
|
The timeout indicates end of dialing and the call can then be setup.
|
|
|
|
0 = notApplicable
|
|
Default=2 sec."
|
|
::= { agnVoiceSwConfEntry 5}
|
|
|
|
agnVoiceSwConfLidt OBJECT-TYPE
|
|
SYNTAX Integer32 (0..30)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LIDT: Long Inter Digit Timeout used as timer between digits before routing
|
|
is completed. If no digits were dialed and LIDT expired then the user will get
|
|
an error tone and the call will be disconnected.
|
|
|
|
0 = notApplicable
|
|
Default=15 sec."
|
|
::= { agnVoiceSwConfEntry 6}
|
|
|
|
agnVoiceSwConfDialPlan OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
staticDialPlan(2),
|
|
staticDialPlanPlus(3),
|
|
flexDialPlan(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the Dialing Plan method that will be used in the Voice Switching.
|
|
Static Dialing Plan - Routing is defined by the current device Zone and
|
|
Node ID in the Network.
|
|
Static Dialing Plan Plus - Includes the Static Dialing Plan but contains an
|
|
addition of defining the number of dialed digits.
|
|
Flexible Dialing Plan - Routing is defined in a flexible form.
|
|
In this plan the user can configure the extension number
|
|
of a local voice channel, Route a call to a remote
|
|
destination and enter the Number of Digits for a specific
|
|
dial prefix."
|
|
::= { agnVoiceSwConfEntry 7}
|
|
|
|
|
|
agnVoiceSwConfRtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnVoiceSwConfRtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Routing Table for Voice Switching."
|
|
::= { agnVoiceSwitching 2 }
|
|
|
|
agnVoiceSwConfRtEntry OBJECT-TYPE
|
|
SYNTAX AgnVoiceSwConfRtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { agnVoiceSwConfRtDbId, agnVoiceSwConfRtIdx }
|
|
::= { agnVoiceSwConfRtTable 1}
|
|
|
|
AgnVoiceSwConfRtEntry ::=
|
|
SEQUENCE {
|
|
agnVoiceSwConfRtDbId INTEGER,
|
|
agnVoiceSwConfRtIdx Integer32,
|
|
agnVoiceSwConfRtDigits DisplayString,
|
|
agnVoiceSwConfRtAction INTEGER,
|
|
agnVoiceSwConfRtData DisplayString,
|
|
agnVoiceSwConfRtSlot INTEGER,
|
|
agnVoiceSwConfRtPort Integer32,
|
|
agnVoiceSwConfRtDlci Integer32,
|
|
agnVoiceSwConfRtRowStatus RowStatus,
|
|
agnVoiceSwConfRtMaxCalls Integer32,
|
|
agnVoiceSwConfRtPriority Integer32
|
|
}
|
|
|
|
agnVoiceSwConfRtDbId OBJECT-TYPE
|
|
SYNTAX INTEGER { active(1), temporary(255) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active or Temporary Table.
|
|
Both configurations can be read but only the Temporary can
|
|
be written to."
|
|
::= { agnVoiceSwConfRtEntry 1 }
|
|
|
|
agnVoiceSwConfRtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The Index of the row."
|
|
::= { agnVoiceSwConfRtEntry 2 }
|
|
|
|
agnVoiceSwConfRtDigits OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE(1..7) )
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Dialed digits: Series of digits 0...9, '*', '#' or '%'.
|
|
The '*' and '#' can have many uses according to the user's decision.
|
|
For example, they can be used as part of the Dialed Number,
|
|
they exist on the phone number panel.
|
|
'*' can also be used instead of a series of numbers.
|
|
The '%' means any digits (wildcard) and is used without a series of digits.
|
|
|
|
When the agnVoiceSwConfRtAction is del (7), the series of digits that
|
|
are configured via this MIB object will be deleted from the prefix of
|
|
the dialed number."
|
|
::= { agnVoiceSwConfRtEntry 3 }
|
|
|
|
agnVoiceSwConfRtAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
zone(2),
|
|
node(3),
|
|
shortDialing(4),
|
|
in(5), -- Internal switching
|
|
hgr(6), -- Hunt Group
|
|
del(7), -- Delete a prefix from the Dialed Number
|
|
rep(8), -- Replace a prefix with a given string of digits
|
|
pri(9), -- for ISDN
|
|
bri(10),-- for ISDN
|
|
numDigDP(11), -- Number of Digits user will dial according to Dialing Plan.
|
|
route(12), -- Route to a Remote Destination
|
|
ext(13) -- Extension to a local voice channel
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Action that the system should perform for the digits:
|
|
agnVoiceSwConfRtDigits.
|
|
The action that is allowed depends on the Dialing Plan.
|
|
Here is the list of the allowed actions:
|
|
For Static Dialing Plan - zone, node, in, shortDialing, hgr, del, rep
|
|
For Static Dialing Plan Plus - zone, node, in, shortDialing, hgr, del, rep, numDigDP
|
|
For Flexible Dialing Plan - hgr, del, rep, numDigDP, route, ext"
|
|
DEFVAL { notApplicable }
|
|
::= { agnVoiceSwConfRtEntry 4 }
|
|
|
|
agnVoiceSwConfRtData OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(1..7))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This field is relevant for actions hgr(6), and rep(8), numDigDP(11)
|
|
and contains the following information:
|
|
For hgr - the number of the Hunt Group.
|
|
For rep - the number of digits to be replaced with.
|
|
For numDigDP - the number of digits collected before establishing the call.
|
|
0 indicates no defined length. In this case SIDT will be used."
|
|
-- DEFVAL {"0" }
|
|
::= { agnVoiceSwConfRtEntry 5 }
|
|
|
|
agnVoiceSwConfRtSlot OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
noConnect(2),
|
|
cl (3),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Routing Slot- Relevant for actions zone(2), node(3), shortDialing(4),
|
|
route(12), ext(13)."
|
|
DEFVAL { noConnect }
|
|
::= { agnVoiceSwConfRtEntry 6 }
|
|
|
|
agnVoiceSwConfRtPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Routing Port- Relevant for actions zone(2), node(3), shortDialing(4),
|
|
route(12), ext(13).
|
|
100=noConnect (for non-routing case)."
|
|
DEFVAL { 0 }
|
|
::= { agnVoiceSwConfRtEntry 7 }
|
|
|
|
agnVoiceSwConfRtDlci OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Routing DLCI- Relevant for actions zone(2), node(3), shortDialing(4),
|
|
route(12), ext(13).
|
|
Valid values:
|
|
0=notApplicable (for non-routing case).
|
|
1, 16..991 "
|
|
DEFVAL { 15 }
|
|
::= { agnVoiceSwConfRtEntry 8 }
|
|
|
|
agnVoiceSwConfRtRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Status of the row for creating/deleting entries in the table.
|
|
The only possible supported RowStatus vaules are
|
|
active (1), notInService (2), notReady(3), createAndGo(4),
|
|
createAndWait(5) and destroy(6)."
|
|
::= { agnVoiceSwConfRtEntry 9 }
|
|
|
|
agnVoiceSwConfRtMaxCalls OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum no. of simultaneous voice calls that are allowed in the direction
|
|
defined by the current entry.
|
|
|
|
Default=0 (No Limit)."
|
|
::= { agnVoiceSwConfRtEntry 10}
|
|
|
|
agnVoiceSwConfRtPriority OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique priority of the Voice Switching Route.
|
|
1 is the lowest priority and 7 is the highest priority.
|
|
0 means N/A "
|
|
::= { agnVoiceSwConfRtEntry 11}
|
|
|
|
|
|
agnVoiceSwConfHGTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnVoiceSwConfHGEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of Hunt Groups."
|
|
::= { agnVoiceSwitching 5 }
|
|
|
|
agnVoiceSwConfHGEntry OBJECT-TYPE
|
|
SYNTAX AgnVoiceSwConfHGEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { agnVoiceSwConfHGdbIdx, agnVoiceSwConfHGIdx }
|
|
::= { agnVoiceSwConfHGTable 1}
|
|
|
|
AgnVoiceSwConfHGEntry ::=
|
|
SEQUENCE {
|
|
agnVoiceSwConfHGdbIdx INTEGER,
|
|
agnVoiceSwConfHGIdx Integer32,
|
|
agnVoiceSwConfHGConnect INTEGER,
|
|
agnVoiceSwConfHGExt Integer32,
|
|
agnVoiceSwConfHGExtString SnmpAdminString,
|
|
agnVoiceSwConfHGUserParams SnmpAdminString,
|
|
agnVoiceSwConfHGStatus INTEGER
|
|
}
|
|
|
|
agnVoiceSwConfHGdbIdx OBJECT-TYPE
|
|
SYNTAX INTEGER { active(1), temporary(255) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active or Temporary Table.
|
|
Both configurations can be read but only the Temporary can
|
|
be written to."
|
|
::= { agnVoiceSwConfHGEntry 1}
|
|
|
|
agnVoiceSwConfHGIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For Vmux-300 devices -
|
|
This object represents a combination of
|
|
- Hunt Group number and Extension number OR
|
|
- Port number and Extension number.
|
|
|
|
For other devices (e.g. MXcess, MP-2100H) -
|
|
There may be up to 10 Hunt Groups per MXcess. That's the
|
|
index of the hunt group relevant to this row."
|
|
::= { agnVoiceSwConfHGEntry 2}
|
|
|
|
agnVoiceSwConfHGConnect OBJECT-TYPE
|
|
SYNTAX INTEGER { no(2), yes(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the hunt group should be
|
|
considered in any of the mux algorithms."
|
|
::= { agnVoiceSwConfHGEntry 3}
|
|
|
|
agnVoiceSwConfHGExt OBJECT-TYPE
|
|
SYNTAX Integer32(0..99)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the extension number of the hunt group.
|
|
0 is for not valid. The allowed range is 10 - 99."
|
|
DEFVAL { 0 }
|
|
::= { agnVoiceSwConfHGEntry 4}
|
|
|
|
agnVoiceSwConfHGExtString OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the extension string of the hunt group.
|
|
This string is a combination of digits, * and #."
|
|
::= { agnVoiceSwConfHGEntry 5}
|
|
|
|
agnVoiceSwConfHGUserParams OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the User's parameters."
|
|
::= { agnVoiceSwConfHGEntry 6}
|
|
|
|
agnVoiceSwConfHGStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
active (1),
|
|
notInService (2),
|
|
notReady (3),
|
|
createAndGo (4),
|
|
createAndWait (5),
|
|
destroy (6),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables the user to create/delete entries in this table.
|
|
Its usage for values (1)..(6) should be identical to RowStatus SYNTAX.
|
|
notApplicable(255) - should be used when the table is static
|
|
(i.e. whenever create/delete entries is not allowed)."
|
|
::= { agnVoiceSwConfHGEntry 7}
|
|
|
|
--
|
|
-- Signaling Profiles for MP-2200 and MP-2100
|
|
--
|
|
-- Legacy Profile Table
|
|
|
|
agnSigProfileTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnSigProfileEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"- For products supporting more than one configuration, the write operation
|
|
into the Table is valid only to the TmpCnfg entry.
|
|
- For products that do not support configurations, the write operation
|
|
into the Table will be to agnSigProfileCnfgIdx=1.
|
|
The table includes signaling profile parameters for Legacy Profiles."
|
|
::= { agnSigProfile 1}
|
|
|
|
agnSigProfileEntry OBJECT-TYPE
|
|
SYNTAX AgnSigProfileEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnSigProfileCnfgIdx, agnSigProfileIdx, agnSigProfileRxTx}
|
|
::= { agnSigProfileTable 1}
|
|
|
|
AgnSigProfileEntry ::=
|
|
SEQUENCE {
|
|
agnSigProfileCnfgIdx Integer32,
|
|
agnSigProfileIdx Integer32,
|
|
agnSigProfileRxTx INTEGER,
|
|
agnSigProfileABCD OCTET STRING,
|
|
agnSigProfileEcanActSignal INTEGER,
|
|
agnSigProfileEcanRespDelay Unsigned32
|
|
}
|
|
|
|
agnSigProfileCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg.
|
|
For products supporting more than one configuration,the write
|
|
operation is valid only to the TmpCnfg.
|
|
For Gmux2000 the range limitation (1..255) was discarded
|
|
since the Idx is computed as: <IO Card No.> x 1000 + 255."
|
|
::= { agnSigProfileEntry 1}
|
|
|
|
agnSigProfileIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..5)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Signaling Profile (1..5).
|
|
For MP-104/204, only Profile=1 will exist."
|
|
::= { agnSigProfileEntry 2}
|
|
|
|
agnSigProfileRxTx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rx (1),
|
|
tx (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates if the following objects refer to:
|
|
Rx or Tx translation.
|
|
Rx : ML->IO
|
|
Tx : IO->ML .
|
|
For MP-104/204, that means:
|
|
Rx : Signaling to FXS CH
|
|
Tx : Signaling to E1 Link. "
|
|
::= { agnSigProfileEntry 3}
|
|
|
|
agnSigProfileABCD OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For MP-2100/MP-2200 and for MP-104/204 from R2:
|
|
This object represents 6 parameters, by 3 Octets :
|
|
Busy Code-MSB nibble, - applicable only for Rx translation
|
|
Idle Code- nibble, - applicable only for Rx translation
|
|
D Bit Code- nibble,
|
|
C Bit Code- nibble,
|
|
B Bit Code- nibble,
|
|
A Bit Code-LSB nibble.
|
|
|
|
Each of Busy and Idle Code nibble will have the valid values:
|
|
0000 .. FFFF.
|
|
|
|
Each of A,B,C,D Bit Code nibble represents:
|
|
0 hex = 0000 = 0
|
|
1 hex = 0001 = 1
|
|
2 hex = 0010 = A bit
|
|
3 hex = 0011 = B bit
|
|
4 hex = 0100 = C bit
|
|
5 hex = 0101 = D bit
|
|
6 hex = 0110 = A bit inverse
|
|
7 hex = 0111 = B bit inverse
|
|
8 hex = 1000 = C bit inverse
|
|
9 hex = 1001 = D bit inverse
|
|
A-F hex - not used (invalid values)
|
|
|
|
For MP-104/204 R1:
|
|
This object represents 3 parameters, by 2 Octets :
|
|
Bit 1 = Bit A - OFF Hook for Tx ; Ring for Rx (LSB)
|
|
Bit 2 = Bit B - OFF Hook for Tx ; Ring for Rx
|
|
Bit 3 = Bit C - OFF Hook for Tx ; Ring for Rx
|
|
Bit 4 = Bit D - OFF Hook for Tx ; Ring for Rx
|
|
Bit 5 = Bit A - ON Hook for Tx ; Idle for Rx
|
|
Bit 6 = Bit B - ON Hook for Tx ; Idle for Rx
|
|
Bit 7 = Bit C - ON Hook for Tx ; Idle for Rx
|
|
Bit 8 = Bit D - ON Hook for Tx ; Idle for Rx
|
|
|
|
Bit 9 = Bit A - OOS State for both Tx and Rx
|
|
Bit 10 = Bit B - OOS State for both Tx and Rx
|
|
Bit 11 = Bit C - OOS State for both Tx and Rx
|
|
Bit 12 = Bit D - OOS State for both Tx and Rx
|
|
Bit 13 = Spare (always 0)
|
|
Bit 14 = Spare (always 0)
|
|
Bit 15 = Spare (always 0)
|
|
Bit 16 = Spare (always 0) (MSB)
|
|
|
|
When the object is not applicable, the Octet String will have 0 bytes."
|
|
::= { agnSigProfileEntry 4}
|
|
|
|
agnSigProfileEcanActSignal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
aBit1 (2),
|
|
aBit0 (3),
|
|
bBit1 (4),
|
|
bBit0 (5),
|
|
cBit1 (6),
|
|
cBit0 (7),
|
|
dBit1 (8),
|
|
dBit0 (9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Echo Canceller Activation Signal.
|
|
This object specifies which BIT (A, B, C, or D) and which value (0 or 1)
|
|
will be used for the echo canceller activation. The inverse value will cause the
|
|
deactivation of the echo canceller."
|
|
::= { agnSigProfileEntry 5}
|
|
|
|
agnSigProfileEcanRespDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Echo Canceller Response Delay.
|
|
This object specifies the response delay in msec for the activation/deactivation
|
|
of the echo canceller.
|
|
The value should be in multiples of 100 msec: 100, 200, 300, ...2000."
|
|
::= { agnSigProfileEntry 6}
|
|
|
|
|
|
-- General Profile Table
|
|
|
|
agnSigProfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgnSigProfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry. This is the general table of signaling profiles."
|
|
::= { agnSigProfile 2}
|
|
|
|
agnSigProfEntry OBJECT-TYPE
|
|
SYNTAX AgnSigProfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {agnSigProfCnfgIdx, agnSigProfIdx}
|
|
::= { agnSigProfTable 1}
|
|
|
|
AgnSigProfEntry ::=
|
|
SEQUENCE {
|
|
agnSigProfCnfgIdx Integer32,
|
|
agnSigProfIdx Integer32,
|
|
agnSigProfName DisplayString,
|
|
agnSigProfType INTEGER
|
|
}
|
|
|
|
agnSigProfCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg.
|
|
The write operation is valid only to the TmpCnfg."
|
|
::= { agnSigProfEntry 1}
|
|
|
|
agnSigProfIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..5)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Signaling Profile (1..5)."
|
|
::= { agnSigProfEntry 2}
|
|
|
|
agnSigProfName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..12))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Profile Name given by user."
|
|
::= { agnSigProfEntry 3 }
|
|
|
|
agnSigProfType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
legacy (2),
|
|
r2Cas (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Profile Type.
|
|
legacy - usual signaling. The parameters for the Legacy Profiles
|
|
are detailed in the agnSigProfileTable, above.
|
|
r2Cas - R2 signaling. The parameters for the R2 Profiles are detailed
|
|
in the r2 ProfileCnfg tables (belong to r2If). "
|
|
::= { agnSigProfEntry 4 }
|
|
|
|
|
|
--
|
|
-- TS Assignment Table from system point of view
|
|
--
|
|
-- agnTsTable OBJECT-TYPE ::= { agnSystemTs 1}
|
|
--
|
|
-- For this table see tsa.txt file.
|
|
|
|
|
|
-- General System Voice parameters
|
|
--
|
|
systemVoiceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SystemVoiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"General Parameters for voice - system level."
|
|
::= { systemVoice 1 }
|
|
|
|
systemVoiceEntry OBJECT-TYPE
|
|
SYNTAX SystemVoiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { systemVoiceConfIdx }
|
|
::= { systemVoiceTable 1}
|
|
|
|
SystemVoiceEntry ::=
|
|
SEQUENCE {
|
|
systemVoiceConfIdx Integer32,
|
|
systemVoiceNationalTone INTEGER,
|
|
systemVoicePacketRate Unsigned32,
|
|
systemVoiceFaxSupport INTEGER,
|
|
systemVoiceFaxRate INTEGER,
|
|
systemVoiceModemSupport INTEGER,
|
|
systemVoiceCoderAndRate INTEGER,
|
|
systemVoiceEchoCanceler INTEGER,
|
|
systemVoiceTxGain Integer32,
|
|
systemVoiceDtmfRelayMethod INTEGER,
|
|
systemVoiceDtmfRelayRxPayloadType Unsigned32,
|
|
systemVoiceDtmfRelayPayloadTypeNeg INTEGER,
|
|
systemVoiceDtmfRelayTxPayloadType Unsigned32
|
|
}
|
|
|
|
systemVoiceConfIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed - Active or Temporary Configurations.
|
|
Idx 255 relates to the temporary TmpCnfg.
|
|
All configurations can be read but only the Temporary can
|
|
be written to."
|
|
::= { systemVoiceEntry 1}
|
|
|
|
systemVoiceNationalTone OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
usa (2),
|
|
australia (3),
|
|
brazil (4),
|
|
canada (5),
|
|
france (6),
|
|
germany (7),
|
|
israel (8),
|
|
mexico (9),
|
|
portugal (10),
|
|
russia (11),
|
|
spain (12),
|
|
unitedKingdom (13),
|
|
czech (14),
|
|
china (15)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tone Characteristics (Amplitude, Frequency, delays etc.).
|
|
These characteristics are defined according to the country."
|
|
::= { systemVoiceEntry 2}
|
|
|
|
systemVoicePacketRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the G.729 and G.711 Coders
|
|
transmitted Packet Rate in milliseconds."
|
|
::= { systemVoiceEntry 3}
|
|
|
|
systemVoiceFaxSupport OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
faxRelayT38 (3),
|
|
vbdPassThrou (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the user to Disable/Enable Fax support."
|
|
::= { systemVoiceEntry 4}
|
|
|
|
systemVoiceFaxRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notConnected (1),
|
|
r4800bps (2),
|
|
-- reserved for r7200bps (3)
|
|
r9600bps (4),
|
|
-- reserved for r12000bps (5)
|
|
r14400bps (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Fax Rate limit.
|
|
It is irrelevant when Fax support is NA or disabled."
|
|
::= { systemVoiceEntry 5}
|
|
|
|
systemVoiceModemSupport OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
vbdV152 (3),
|
|
vbdPassThrou (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows the user to Disable/Enable Modem support."
|
|
::= { systemVoiceEntry 6}
|
|
|
|
systemVoiceCoderAndRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
-- reserved for g7231r6300BPS (2)
|
|
-- reserved for g7231r5300BPS (3)
|
|
-- reserved for g729A8KBPS (4)
|
|
g711aLAW (5),
|
|
g711uLAW (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Coder and Rate for the Voice Compression."
|
|
::= { systemVoiceEntry 7}
|
|
|
|
systemVoiceEchoCanceler OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Echo Canceler activation."
|
|
::= { systemVoiceEntry 8}
|
|
|
|
systemVoiceTxGain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Transmit Gain (volume) in dB."
|
|
::= { systemVoiceEntry 9}
|
|
|
|
systemVoiceDtmfRelayMethod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
rfc2833 (1),
|
|
sipInfo (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the DTMF Relay Method
|
|
that is used to transmit DTMF tones.
|
|
|
|
rfc2833(1) - inband DTMF relay according to RFC-2833.
|
|
sipInfo(2) - out of band DTMF relay using SIP INFO method."
|
|
::= { systemVoiceEntry 10}
|
|
|
|
systemVoiceDtmfRelayRxPayloadType OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Rx Payload Type
|
|
for DTMF relay RTP packets.
|
|
It is relevant only when DTMF Relay Method is RFC-2833."
|
|
::= { systemVoiceEntry 11}
|
|
|
|
systemVoiceDtmfRelayPayloadTypeNeg OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether Payload Type Negotiation is used
|
|
(according to RFC-2833) or not.
|
|
It is relevant only when DTMF Relay Method is RFC-2833."
|
|
::= { systemVoiceEntry 12}
|
|
|
|
systemVoiceDtmfRelayTxPayloadType OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Tx Payload Type
|
|
for DTMF relay RTP packets.
|
|
It is relevant only when the Payload Type Negotiation is disabled."
|
|
::= { systemVoiceEntry 13}
|
|
|
|
|
|
systemVoiceCoderTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SystemVoiceCoderEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voice Coders table."
|
|
::= { systemVoice 2 }
|
|
|
|
systemVoiceCoderEntry OBJECT-TYPE
|
|
SYNTAX SystemVoiceCoderEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in Voice Coders table."
|
|
INDEX { systemVoiceCoderConfIdx, systemVoiceCoderPriority }
|
|
::= { systemVoiceCoderTable 1}
|
|
|
|
SystemVoiceCoderEntry ::=
|
|
SEQUENCE {
|
|
systemVoiceCoderConfIdx Unsigned32,
|
|
systemVoiceCoderPriority Unsigned32,
|
|
systemVoiceCoderCoderAndRate INTEGER
|
|
}
|
|
|
|
systemVoiceCoderConfIdx OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The first index of the table.
|
|
|
|
This object might represent the Configuration Index (1..100) being accessed;
|
|
Index=255 relates to the TmpCnfg.
|
|
For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
|
|
|
|
Not-Applicable = 1."
|
|
::= { systemVoiceCoderEntry 1}
|
|
|
|
systemVoiceCoderPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Coder's Priority."
|
|
::= { systemVoiceCoderEntry 2}
|
|
|
|
systemVoiceCoderCoderAndRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
g7231r6300BPS (2),
|
|
g7231r5300BPS (3),
|
|
g729A8KBPS (4),
|
|
g711aLAW (5),
|
|
g711uLAW (6),
|
|
none (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Coder and Rate for the Voice Compression."
|
|
::= { systemVoiceCoderEntry 3}
|
|
|
|
|
|
--
|
|
-- Wan installed module status general information
|
|
--
|
|
mdlSInstTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlSInstEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { statMdlGen 1 }
|
|
|
|
mdlSInstEntry OBJECT-TYPE
|
|
SYNTAX MdlSInstEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { mdlSInstSltIdx }
|
|
::= { mdlSInstTable 1}
|
|
|
|
MdlSInstEntry ::=
|
|
SEQUENCE {
|
|
mdlSInstSltIdx INTEGER,
|
|
mdlSInstCardType INTEGER,
|
|
mdlSHwVersion DisplayString,
|
|
mdlSSwVersion DisplayString,
|
|
mdlSAlrStatus INTEGER,
|
|
mdlSAlrStatusAll INTEGER,
|
|
mdlSMaskedAlrStat INTEGER,
|
|
mdlSMaskedAlrStatAll INTEGER,
|
|
mdlSTstStatusAll INTEGER,
|
|
mdlSClearAlrCmd INTEGER,
|
|
mdlSClearAllAlrCmd INTEGER,
|
|
mdlSTemperature Integer32
|
|
}
|
|
|
|
mdlSInstSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
psA (1),
|
|
psB (2),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify a slot position in the mux.
|
|
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
|
|
are not valid.
|
|
For the Vmux2100 Main Board clA (3) is used."
|
|
::= { mdlSInstEntry 1}
|
|
|
|
mdlSInstCardType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
--
|
|
-- General types
|
|
--
|
|
unknown (1),
|
|
empty (2),
|
|
|
|
-- (3)..(7) are reserved ; they appear in the compress structure
|
|
|
|
acm (9), --alarm module
|
|
--
|
|
-- Power Supply Modules
|
|
--
|
|
ps60W (10),
|
|
ps100W (11),
|
|
-- (12)..(16) are reserved for the Programmed PS cards
|
|
ps (17),
|
|
|
|
--
|
|
-- Cl Modules
|
|
--
|
|
cl1 (20),
|
|
clEth (21),
|
|
cl2 (22),
|
|
cl2Eth (23),
|
|
cl3 (24),
|
|
cl3Eth (25),
|
|
cl1Clk (26), --CL1 with Station Clock (for LRS102)
|
|
--
|
|
-- Packet Cards of Megaplex
|
|
--
|
|
mPh1 (31),
|
|
mPh3 (32),
|
|
mPh1T1DSU (33),
|
|
mPh1T1CSU (34),
|
|
mPh1E1DSU (35),
|
|
mPh1E1LTU (36),
|
|
|
|
-- TDM Cards
|
|
|
|
mtmlFT1 (37),
|
|
mtmlFE1 (38),
|
|
mtmlH4E1 (39),
|
|
mtmlH4E12W (40),
|
|
mtmlH4T1 (41),
|
|
mtmlH4T12W (42),
|
|
mtHsh4E1 (43),
|
|
mtHsh4E12W (44),
|
|
mtHsh4T1 (45),
|
|
mtHsh4T12W (46),
|
|
mtmlH2E1 (47),
|
|
mtmlH2E12W (48),
|
|
mtmlH2T1 (49),
|
|
mtmlH2T12W (50),
|
|
hsh2E1 (51),
|
|
hsh2E12W (52),
|
|
hsh2T1 (53),
|
|
hsh2T12W (54),
|
|
mlIp (55),
|
|
mtml4Ip (56),
|
|
ml20N1 (57),
|
|
ml20N2 (58),
|
|
|
|
-- Packet Cards of Megaplex
|
|
|
|
mPl6 (60),
|
|
mPl3 (61),
|
|
|
|
-- VF cards of Megaplex
|
|
vf24T1 (62),
|
|
vf30E1 (63),
|
|
vf48T1 (64),
|
|
vf60E1 (65),
|
|
|
|
-- Vmux-2100 Main Link cards
|
|
ml2E1 (68),
|
|
ml4E1 (69),
|
|
ml2T1 (70),
|
|
ml4T1 (71),
|
|
|
|
mPv4 (72),
|
|
--
|
|
-- TDM Cards
|
|
--
|
|
vc16A (73),
|
|
vc8EandM (74),
|
|
vc8Fxo (75),
|
|
vc8Fxs (76),
|
|
vc16EandM (77),
|
|
vc16Fxo (78),
|
|
vc16Fxs (79),
|
|
|
|
vf3EandM (80),
|
|
vf3Fxs (81),
|
|
vf3Fxo (82),
|
|
|
|
vfPbx (83),
|
|
vfPbxT1 (84),
|
|
vfPbxE1 (85),
|
|
|
|
mtMlE2S (86), --Single Link
|
|
mtMlE2D (87), --Dual Link
|
|
mtMlF2T1 (88),
|
|
mtMlF2E1 (89),
|
|
mtMlT1Fiber (90),
|
|
mtMlE1Fiber (91),
|
|
mtMlT1FiberFb (92),
|
|
mtMlE1FiberFb (93),
|
|
mtmlHE1 (94),
|
|
mtmlH1E1 (95),
|
|
mtmlHSE1 (96),
|
|
ml20 (97),
|
|
mtMl4T1 (98),
|
|
mtMl4E1 (99),
|
|
|
|
mtMl1T1DSU (100),
|
|
mtMl1T1CSU (101),
|
|
mtMl1E1DSU (102),
|
|
mtMl1E1LTU (103),
|
|
mtMl1T1DSUfb (104),
|
|
mtMl1T1CSUfb (105),
|
|
mtMl1E1DSUfb (106),
|
|
mtMl1E1LTUfb (107),
|
|
mtMl2T1 (108),
|
|
mtMl2E1 (109),
|
|
|
|
ls2CcittX50 (110),
|
|
ls2CcittX58 (111),
|
|
ls2ATandTSdm (112),
|
|
ls2ACcittX50 (113),
|
|
ls2ACcittX58 (114),
|
|
ls2AATandTSdm (115),
|
|
ls2A2Ts (116),
|
|
ls2M (117),
|
|
|
|
mtMlT1 (118),
|
|
mtMlE1 (119),
|
|
|
|
hs2 (120),
|
|
hs3 (121),
|
|
hsq (122),
|
|
hs703 (123),
|
|
hsQM (124),
|
|
hsqN (125),
|
|
hs6 (126),
|
|
hs12 (127),
|
|
hsDp (128),
|
|
hsp (129),
|
|
|
|
hs4T1 (130),
|
|
hs4E1 (131),
|
|
hs4 (132),
|
|
hsEth (133),
|
|
|
|
ml8T1 (134),
|
|
ml8E1 (135),
|
|
|
|
-- Vmux-2100 Voice cards
|
|
vc2E1 (136),
|
|
vc4E1 (137),
|
|
vc2T1 (138),
|
|
vc4T1 (139),
|
|
|
|
vc2EandM (140),
|
|
vc2Fxs1Plar (141),
|
|
vc2Fxo1 (142),
|
|
vc2Fxs2 (143),
|
|
vc2Fxo2 (144),
|
|
vc2Fxs3 (145),
|
|
vc2Fxo3 (146),
|
|
vc26EandM (147),
|
|
mtvc2 (148),
|
|
vc2R2Fxs (149),
|
|
|
|
hsu (150),
|
|
|
|
mbeA (151),
|
|
mbeB (152),
|
|
mbeU (153),
|
|
tre (154),
|
|
|
|
hsuI (155),
|
|
hsr (156),
|
|
hss (157),
|
|
hsu1 (158),
|
|
|
|
ls12 (159),
|
|
ls6 (160),
|
|
ls6V1EandM (161),
|
|
ls6V1Fxo (162),
|
|
ls6V1Fxs (163),
|
|
ls6V2EandM (164),
|
|
ls6V2Fxo (165),
|
|
ls6V2Fxs (166),
|
|
ls6VfEandM (167),
|
|
ls6VfFxo (168),
|
|
ls6VfFxs (169),
|
|
|
|
vc3EandM (170),
|
|
vc3Fxo (171),
|
|
vc3Fxs (172),
|
|
|
|
vcPbx (173),
|
|
vcPbxT1 (174),
|
|
vcPbxE1 (175),
|
|
|
|
vc6EandM (176),
|
|
vc6Fxo (177),
|
|
vc6Fxs (178),
|
|
|
|
vcq (179),
|
|
|
|
ls6n (180),
|
|
|
|
--
|
|
-- Packet Cards of MAXcess and Hybrid
|
|
--
|
|
|
|
-- High speed cards
|
|
|
|
mhs1V36 (181),
|
|
mhs1V35 (182),
|
|
mhs1G703 (183),
|
|
mhs1DDS (184),
|
|
mhs3 (185),
|
|
mhs1X21 (186),
|
|
mhs1V24 (187),
|
|
mhs4 (188),
|
|
mhsE1Hs (189),
|
|
mhsT1Hs (190),
|
|
mhsHyE1Hs (191), -- 2 HS ports + 1 Hybrid E1 port
|
|
mhsHyT1Hs (192), -- 2 HS ports + 1 Hybrid T1 port
|
|
mlfHybE1Hs (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port
|
|
mlfHybT1Hs (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port
|
|
|
|
-- T1/E1 cards
|
|
|
|
mhs2e1 (195),
|
|
mhs2t1 (196),
|
|
mhsHy2e1 (197), -- 2 Hybrid E1 ports
|
|
mhsHy2t1 (198), -- 2 Hybrid T1 ports
|
|
mlfHybE12 (199), -- Fiber Optic Hybrid: 2 E1 ports
|
|
|
|
|
|
-- Low speed cards
|
|
|
|
mls6 (200),
|
|
mls3 (201),
|
|
|
|
|
|
-- More T1/E1 cards
|
|
|
|
mlHybAtmE1 (202), -- Hybrid ATM E1
|
|
mlHybAtmT1 (203), -- Hybrid ATM T1
|
|
mlfHybT12 (204), -- Fiber Optic Hybrid: 2 T1 ports
|
|
|
|
|
|
-- Voice cards
|
|
|
|
mvc8 (205), -- MVC-8 name in marketing: MVC-4N
|
|
mvc8PbxE1 (206),
|
|
mvc8PbxT1Dsu (207),
|
|
mvc8PbxT1Csu (208),
|
|
mvc8PbxE1Slave (209),
|
|
|
|
mvc4 (210),
|
|
mvc4PbxE1 (211),
|
|
mvc4PbxT1Dsu (212),
|
|
mvc4PbxT1Csu (213),
|
|
mvc4PbxE1Slave (214),
|
|
mvc4PbxT1Slave (215),
|
|
|
|
mvc8PbxT1Slave (216), -- MVC-8 T1 Slave is here
|
|
mvc8ExtAnalog (217), -- MVC-8 with 8 External ports
|
|
mvcE1 (218), -- 8 External ports & 30 Internals
|
|
mvcT1 (219), -- 8 External ports & 24 Internals
|
|
|
|
-- ISDN for Maxcess
|
|
mhsS (220),
|
|
mhsU (221),
|
|
mhsPriE1 (222),
|
|
mhsPriT1 (223),
|
|
|
|
--Card of MP-2100/4
|
|
hsEthSwitch (224),
|
|
|
|
-- CCS for Maxcess & MPH
|
|
mPriE1FramerCcs (225),
|
|
mPriT1FramerCcs (226),
|
|
mPriE1SlaveCcs (227),
|
|
mPriT1SlaveCcs (228),
|
|
mDualBri (229),
|
|
|
|
--Voice cards for MP
|
|
vc12EandM (230),
|
|
vc12Fxo (231),
|
|
vc12Fxs (232),
|
|
vc6aEandM (233),
|
|
vc6aFxo (234),
|
|
vc6aFxs (235),
|
|
vc6AgFxo (236),
|
|
vc6AgFxs (237),
|
|
vc6a4LB (238),
|
|
|
|
--Video card for MP
|
|
vid (239),
|
|
|
|
--ISDN cards for MP
|
|
hsu12 (240),
|
|
hsu6 (241),
|
|
hss12 (242),
|
|
hss6 (243),
|
|
|
|
-- MPH and MP-2100/4 cards
|
|
hsDp3 (244),
|
|
hsDp6 (245),
|
|
|
|
-- MP-2100/4 card
|
|
hsf1 (246),
|
|
|
|
-- More Hybrid cards + IP cards for MPH
|
|
mhsHyE1 (247), -- 1 Hybrid E1 port
|
|
mhsHyT1 (248), -- 1 Hybrid T1 port
|
|
mhsIp (249), -- 1 Eth port + 1 HS port
|
|
mlIpHs (250), -- 1 Eth port + 3 HS ports
|
|
mlHybIpE1 (251), -- 1 Eth port + 1 HS port + 1 E1
|
|
mlHybIpT1 (252), -- 1 Eth port + 1 HS port + 1 T1
|
|
|
|
-- VOIP cards for MPH & MX
|
|
mvg1Lan (253),
|
|
mvg2Lan (254),
|
|
|
|
-- MP-2100/4 card
|
|
vc4Fxs (255),
|
|
vc4EandM (256),
|
|
vc4Fxo (257),
|
|
hsf2 (258),
|
|
|
|
-- More VOIP cards for MPH
|
|
mvgSwitch4Lan (260),
|
|
|
|
--SHDSL cards of Megaplex
|
|
msl4E1W2 (261),
|
|
msl4E1W4 (262),
|
|
msl8E1W2 (263),
|
|
msl4E1W2Eth (264),
|
|
msl8E1W2Eth (265),
|
|
asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH)
|
|
asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH)
|
|
asmi54c (268), -- & LRS-102 (ETH only)
|
|
|
|
--HS cards of Megaplex
|
|
hs6N (271),
|
|
hs12N (272),
|
|
hsNRZ (273),
|
|
|
|
-- Vmux 2100 Enhanced Voice Cards
|
|
evc2E1 (281),
|
|
evc4E1 (282),
|
|
evc2T1 (283),
|
|
evc4T1 (284),
|
|
|
|
-- Vmux-2200 Voice cards
|
|
vc2E1Pri (285),
|
|
vc4E1Pri (286),
|
|
|
|
-- MP Voice cards
|
|
vc4OmniEandM (291),
|
|
vc4OmniWestern (292),
|
|
|
|
-- MP-4100 and/or LRS-102 cards
|
|
clx1 (301),
|
|
clx1GbE (302),
|
|
clx1S155 (303),
|
|
clx1S155GbE (304),
|
|
ml8T1Eth (305),
|
|
ml8E1Eth (306),
|
|
op106cEth (307), --no external T1
|
|
op108cEth (308), --no external E1
|
|
op106cEthT1 (309), --with external T1 (used also by LRS-102)
|
|
op108cEthE1 (310), --with external E1 (used also by LRS-102)
|
|
op108cEthE1Unbal (311), --used only by LRS-102
|
|
mpw1 (312),
|
|
|
|
-- VFS cards of Megaplex
|
|
vfs24T1 (321),
|
|
vfs30E1 (322),
|
|
vfs48T1 (323), --2T1
|
|
vfs60E1 (324), --2E1
|
|
|
|
-- MiniCVS cards
|
|
mm4E1 (325),
|
|
mm4T1 (326),
|
|
mm8E1 (327),
|
|
mm8T1 (328),
|
|
mm12E1 (329),
|
|
mm12T1 (330),
|
|
mm16E1 (331),
|
|
mm16T1 (332)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the type of card installed
|
|
in the specific slot position.
|
|
Only PS cards are possible in the PS slots.
|
|
Only CL cards are possible in the CL slots.
|
|
Only IO cards are possible in the IO slots."
|
|
::= { mdlSInstEntry 2}
|
|
|
|
mdlSHwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Hardware version of the
|
|
installed card in the specific slot position."
|
|
::= { mdlSInstEntry 3 }
|
|
|
|
mdlSSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Software version of the
|
|
installed card in the specific slot position."
|
|
::= {mdlSInstEntry 4}
|
|
|
|
mdlSAlrStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the alarm state at module level, i.e. lower level
|
|
(port alarms) status is not included.
|
|
This attribute will be set to:
|
|
critical(7) - when there is at least one active (state ON)
|
|
critical alarm,
|
|
otherwise it will be set to
|
|
major(5) - when there is at least one active (state ON)
|
|
major alarm,
|
|
otherwise it will be set to
|
|
minor(4) - if there is at least one active (state ON) minor
|
|
alarm,
|
|
otherwise it will be set to
|
|
warning(6) - if there is at least one active (state ON)
|
|
warning alarm,
|
|
otherwise it will be set to
|
|
event(3) - if there was at least one alarm event (including
|
|
state on,off events) since the last clear operation."
|
|
::= { mdlSInstEntry 5 }
|
|
|
|
mdlSAlrStatusAll OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the alarm state in the module-all level, i.e. lower level
|
|
(port alarms) included.
|
|
This attribute will be set to:
|
|
critical(7) - when there is at least one active (state ON)
|
|
critical alarm,
|
|
otherwise it will be set to
|
|
major(5) - when there is at least one active (state ON)
|
|
major alarm,
|
|
otherwise it will be set to
|
|
minor(4) - if there is at least one active (state ON) minor
|
|
alarm,
|
|
otherwise it will be set to
|
|
warning(6) - if there is at least one active (state ON)
|
|
warning alarm,
|
|
otherwise it will be set to
|
|
event(3) - if there was at least one alarm event (including
|
|
state on,off events) since the last clear operation."
|
|
::= { mdlSInstEntry 6 }
|
|
|
|
mdlSMaskedAlrStat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the alarm state at module level, [i.e. lower level
|
|
(port alarms) status is not included],including Masked alarms.
|
|
This attribute will be set to:
|
|
critical(7) - when there is at least one active (state ON)
|
|
critical alarm,
|
|
otherwise it will be set to
|
|
major(5) - when there is at least one active (state ON)
|
|
major alarm,
|
|
otherwise it will be set to
|
|
minor(4) - if there is at least one active (state ON) minor
|
|
alarm,
|
|
otherwise it will be set to
|
|
warning(6) - if there is at least one active (state ON)
|
|
warning alarm,
|
|
otherwise it will be set to
|
|
event(3) - if there was at least one alarm event (including
|
|
state on,off events) since the last clear operation."
|
|
::= { mdlSInstEntry 7 }
|
|
|
|
mdlSMaskedAlrStatAll OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the alarm state in the module-all level, i.e. lower level
|
|
(port alarms) included, including Masked alarms.
|
|
This attribute will be set to:
|
|
critical(7) - when there is at least one active (state ON)
|
|
critical alarm,
|
|
otherwise it will be set to
|
|
major(5) - when there is at least one active (state ON)
|
|
major alarm,
|
|
otherwise it will be set to
|
|
minor(4) - if there is at least one active (state ON) minor
|
|
alarm,
|
|
otherwise it will be set to
|
|
warning(6) - if there is at least one active (state ON)
|
|
warning alarm,
|
|
otherwise it will be set to
|
|
event(3) - if there was at least one alarm event (including
|
|
state on,off events) since the last clear operation."
|
|
::= { mdlSInstEntry 8 }
|
|
|
|
mdlSTstStatusAll OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute will be set to on(3) when there is at least
|
|
one test in progress on a channel of the card, otherwise
|
|
the value will be off(2)."
|
|
::= { mdlSInstEntry 9 }
|
|
|
|
mdlSClearAlrCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this command to ON, enforces a clear of all the
|
|
alarms in the given slot, excluding alarms of port level.
|
|
The clear operation will not be applied for masked/inverted
|
|
alarms."
|
|
::= { mdlSInstEntry 10 }
|
|
|
|
mdlSClearAllAlrCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this command to ON, enforces a clear of all the
|
|
alarms in the given slot, including all its ports alarms.
|
|
The clear operation will not be applied for masked/inverted
|
|
alarms."
|
|
::= { mdlSInstEntry 11 }
|
|
|
|
mdlSTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature of the card, in Celsius degrees."
|
|
::= { mdlSInstEntry 12 }
|
|
|
|
|
|
mdlSAlrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlSAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The list of card agent alarms ; includes also an alarm
|
|
indicating existence of alarms on its ports if there are any."
|
|
::= { statMdlGen 2 }
|
|
|
|
mdlSAlrEntry OBJECT-TYPE
|
|
SYNTAX MdlSAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {mdlSAlrSltIdx , mdlSAlrIdx}
|
|
::= { mdlSAlrTable 1}
|
|
|
|
MdlSAlrEntry ::=
|
|
SEQUENCE {
|
|
mdlSAlrSltIdx INTEGER,
|
|
mdlSAlrIdx Integer32,
|
|
mdlSAlrCodeDescription DisplayString,
|
|
mdlSAlrCode Integer32,
|
|
mdlSAlrSeverity INTEGER,
|
|
mdlSAlrState INTEGER,
|
|
mdlSAlrCounter Integer32,
|
|
mdlSAlrMask INTEGER,
|
|
mdlSAlrInvert INTEGER
|
|
}
|
|
|
|
mdlSAlrIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify an entry in the alarm status table.
|
|
Users should use the get next function to read this table because
|
|
the indexes are not consecutive."
|
|
::= { mdlSAlrEntry 1}
|
|
|
|
mdlSAlrSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
psA (1),
|
|
psB (2),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the desired slot position.
|
|
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16)
|
|
are not valid.
|
|
For the Vmux2100 Main Board clA (3) is used."
|
|
::= { mdlSAlrEntry 2}
|
|
|
|
mdlSAlrCodeDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is a full text description of the alarm .
|
|
The alarm description includes the following information:
|
|
alarm code, alarm text, alarm severity, Masked or Inverted
|
|
flag and counter."
|
|
::= { mdlSAlrEntry 3}
|
|
|
|
mdlSAlrCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A code identifying the alarm of an entry in the alarm status
|
|
table at card level."
|
|
::= { mdlSAlrEntry 4 }
|
|
|
|
mdlSAlrSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the alarm."
|
|
::= { mdlSAlrEntry 5 }
|
|
|
|
mdlSAlrState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of the alarm."
|
|
::= { mdlSAlrEntry 6 }
|
|
|
|
mdlSAlrCounter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter - how many times the alarm occured since last
|
|
clear operation.
|
|
ON and OFF Alarm will be counted separately."
|
|
::= { mdlSAlrEntry 7 }
|
|
|
|
mdlSAlrMask OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm mask : on/off."
|
|
::= { mdlSAlrEntry 8 }
|
|
|
|
mdlSAlrInvert OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm invert : on/off."
|
|
::= { mdlSAlrEntry 9 }
|
|
|
|
|
|
--
|
|
-- Wan module configuration information
|
|
--
|
|
mdlCPrgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlCPrgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { cnfgMdlGen 1 }
|
|
|
|
mdlCPrgEntry OBJECT-TYPE
|
|
SYNTAX MdlCPrgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { mdlCCnfgIdx, mdlCSltIdx }
|
|
::= { mdlCPrgTable 1}
|
|
|
|
MdlCPrgEntry ::= SEQUENCE {
|
|
mdlCCnfgIdx Integer32,
|
|
mdlCSltIdx INTEGER,
|
|
mdlCPrgCardType INTEGER,
|
|
mdlCNoOfExternPrt Integer32, -- RO
|
|
mdlCNoOfInternPrt Integer32, -- RO
|
|
mdlCWorkMode INTEGER,
|
|
mdlCDhcpClientEnable INTEGER,
|
|
mdlCRdnExists INTEGER, -- RO
|
|
mdlCInterfaces OCTET STRING
|
|
}
|
|
|
|
mdlCCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg(1..100) being
|
|
referred.
|
|
Value 255 specifies the TmpCnfg "
|
|
::= { mdlCPrgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
mdlCSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
psA (1),
|
|
psB (2),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number of the slot
|
|
position where the card is inserted.
|
|
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
|
|
are not valid."
|
|
::= { mdlCPrgEntry 2}
|
|
|
|
mdlCPrgCardType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
--
|
|
-- General types
|
|
--
|
|
unknown (1),
|
|
empty (2),
|
|
|
|
-- (3)..(7) are reserved ; they appear in the compress structure
|
|
|
|
acm (9), --alarm module
|
|
|
|
--
|
|
-- Power Supply Modules
|
|
--
|
|
ps48x60W (10),
|
|
ps48x100W (11),
|
|
ps110x60W (12),
|
|
ps110x100W (13),
|
|
ps220x60W (14),
|
|
ps220x100W (15),
|
|
ps180W (16),
|
|
ps (17),
|
|
|
|
--
|
|
-- Cl Modules
|
|
--
|
|
cl1 (20),
|
|
clEth (21),
|
|
cl2 (22),
|
|
cl2Eth (23),
|
|
cl3 (24),
|
|
cl3Eth (25),
|
|
cl1Clk (26), --CL1 with Station Clock (for LRS102)
|
|
--
|
|
-- Packet Cards of Megaplex
|
|
--
|
|
mPh1 (31),
|
|
mPh3 (32),
|
|
mPh1T1DSU (33),
|
|
mPh1T1CSU (34),
|
|
mPh1E1DSU (35),
|
|
mPh1E1LTU (36),
|
|
|
|
-- TDM Cards
|
|
|
|
mtmlFT1 (37),
|
|
mtmlFE1 (38),
|
|
mtmlH4E1 (39),
|
|
mtmlH4E12W (40),
|
|
mtmlH4T1 (41),
|
|
mtmlH4T12W (42),
|
|
mtHsh4E1 (43),
|
|
mtHsh4E12W (44),
|
|
mtHsh4T1 (45),
|
|
mtHsh4T12W (46),
|
|
mtmlH2E1 (47),
|
|
mtmlH2E12W (48),
|
|
mtmlH2T1 (49),
|
|
mtmlH2T12W (50),
|
|
hsh2E1 (51),
|
|
hsh2E12W (52),
|
|
hsh2T1 (53),
|
|
hsh2T12W (54),
|
|
mlIp (55),
|
|
mtml4Ip (56),
|
|
ml20N1 (57),
|
|
ml20N2 (58),
|
|
|
|
-- Packet Cards of Megaplex
|
|
|
|
mPl6 (60),
|
|
-- mPl3 (61),
|
|
|
|
-- VF cards of Megaplex
|
|
vf24T1 (62),
|
|
vf30E1 (63),
|
|
vf48T1 (64),
|
|
vf60E1 (65),
|
|
|
|
-- Vmux-2100 Main Link cards
|
|
ml2E1 (68),
|
|
ml4E1 (69),
|
|
ml2T1 (70),
|
|
ml4T1 (71),
|
|
|
|
-- mPv4 (72),
|
|
|
|
--
|
|
-- TDM Cards
|
|
--
|
|
vc16A (73),
|
|
vc8EandM (74),
|
|
vc8Fxo (75),
|
|
vc8Fxs (76),
|
|
vc16EandM (77),
|
|
vc16Fxo (78),
|
|
vc16Fxs (79),
|
|
|
|
vf3EandM (80),
|
|
vf3Fxs (81),
|
|
vf3Fxo (82),
|
|
|
|
vfPbx (83),
|
|
vfPbxT1 (84),
|
|
vfPbxE1 (85),
|
|
|
|
mtMlE2S (86), --Single Link
|
|
mtMlE2D (87), --Dual Link
|
|
mtMlF2T1 (88),
|
|
mtMlF2E1 (89),
|
|
mtMlT1Fiber (90),
|
|
mtMlE1Fiber (91),
|
|
mtMlT1FiberFb (92),
|
|
mtMlE1FiberFb (93),
|
|
mtmlHE1 (94),
|
|
mtmlH1E1 (95),
|
|
mtmlHSE1 (96),
|
|
ml20 (97),
|
|
mtMl4T1 (98),
|
|
mtMl4E1 (99),
|
|
|
|
mtMl1T1DSU (100),
|
|
mtMl1T1CSU (101),
|
|
mtMl1E1DSU (102),
|
|
mtMl1E1LTU (103),
|
|
mtMl1T1DSUfb (104),
|
|
mtMl1T1CSUfb (105),
|
|
mtMl1E1DSUfb (106),
|
|
mtMl1E1LTUfb (107),
|
|
mtMl2T1 (108),
|
|
mtMl2E1 (109),
|
|
|
|
ls2CcittX50 (110),
|
|
ls2CcittX58 (111),
|
|
ls2ATandTSdm (112),
|
|
ls2ACcittX50 (113),
|
|
ls2ACcittX58 (114),
|
|
ls2AATandTSdm (115),
|
|
ls2A2Ts (116),
|
|
ls2M (117),
|
|
|
|
mtMlT1 (118),
|
|
mtMlE1 (119),
|
|
|
|
hs2 (120),
|
|
hs3 (121),
|
|
hsq (122),
|
|
hs703 (123),
|
|
hsQM (124),
|
|
hsqN (125),
|
|
hs6 (126),
|
|
hs12 (127),
|
|
hsDp (128),
|
|
hsp (129),
|
|
|
|
hs4T1 (130),
|
|
hs4E1 (131),
|
|
-- hs4 (132),
|
|
hsEth (133),
|
|
|
|
ml8T1 (134),
|
|
ml8E1 (135),
|
|
|
|
-- Vmux-2100 Voice cards
|
|
vc2E1 (136),
|
|
vc4E1 (137),
|
|
vc2T1 (138),
|
|
vc4T1 (139),
|
|
|
|
vc2EandM (140),
|
|
vc2Fxs1Plar (141),
|
|
vc2Fxo1 (142),
|
|
vc2Fxs2 (143),
|
|
vc2Fxo2 (144),
|
|
vc2Fxs3 (145),
|
|
vc2Fxo3 (146),
|
|
vc26EandM (147),
|
|
mtvc2 (148),
|
|
vc2R2Fxs (149),
|
|
|
|
hsu (150),
|
|
|
|
mbeA (151),
|
|
mbeB (152),
|
|
mbeU (153),
|
|
tre (154),
|
|
|
|
hsuI (155),
|
|
hsr (156),
|
|
hss (157),
|
|
hsu1 (158),
|
|
|
|
ls12 (159),
|
|
ls6 (160),
|
|
ls6V1EandM (161),
|
|
ls6V1Fxo (162),
|
|
ls6V1Fxs (163),
|
|
ls6V2EandM (164),
|
|
ls6V2Fxo (165),
|
|
ls6V2Fxs (166),
|
|
ls6VfEandM (167),
|
|
ls6VfFxo (168),
|
|
ls6VfFxs (169),
|
|
|
|
vc3EandM (170),
|
|
vc3Fxo (171),
|
|
vc3Fxs (172),
|
|
|
|
vcPbx (173),
|
|
vcPbxT1 (174),
|
|
vcPbxE1 (175),
|
|
|
|
vc6EandM (176),
|
|
vc6Fxo (177),
|
|
vc6Fxs (178),
|
|
|
|
vcq (179),
|
|
|
|
ls6n (180),
|
|
|
|
--
|
|
-- Packet Cards of Maxcess and Hybrid
|
|
--
|
|
|
|
-- High speed cards
|
|
|
|
mhs1V36 (181),
|
|
mhs1V35 (182),
|
|
mhs1G703 (183),
|
|
mhs1DDS (184),
|
|
mhs3 (185),
|
|
mhs1X21 (186),
|
|
mhs1V24 (187),
|
|
mhs4 (188),
|
|
mhsE1Hs (189),
|
|
mhsT1Hs (190),
|
|
mhsHyE1Hs (191), -- 2 HS ports + 1 Hybrid E1 port
|
|
mhsHyT1Hs (192), -- 2 HS ports + 1 Hybrid T1 port
|
|
mlfHybE1Hs (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port
|
|
mlfHybT1Hs (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port
|
|
|
|
-- T1/E1 cards
|
|
|
|
mhs2e1 (195),
|
|
mhs2t1 (196),
|
|
mhsHy2e1 (197), -- 2 Hybrid E1 ports
|
|
mhsHy2t1 (198), -- 2 Hybrid T1 ports
|
|
mlfHybE12 (199), -- Fiber Optic Hybrid: 2 E1 ports
|
|
|
|
-- Low speed cards
|
|
|
|
mls6 (200),
|
|
mls3 (201),
|
|
|
|
|
|
-- More T1/E1 cards
|
|
mlHybAtmE1 (202), -- Hybrid ATM E1
|
|
mlHybAtmT1 (203), -- Hybrid ATM T1
|
|
mlfHybT12 (204), -- Fiber Optic Hybrid: 2 T1 ports
|
|
|
|
-- Voice cards
|
|
|
|
mvc8 (205), -- MVC-8 name in marketing: MVC-4N
|
|
mvc8PbxE1 (206),
|
|
mvc8PbxT1Dsu (207),
|
|
mvc8PbxT1Csu (208),
|
|
mvc8PbxE1Slave (209),
|
|
|
|
|
|
mvc4 (210),
|
|
mvc4PbxE1 (211),
|
|
mvc4PbxT1Dsu (212),
|
|
mvc4PbxT1Csu (213),
|
|
mvc4PbxE1Slave (214),
|
|
mvc4PbxT1Slave (215),
|
|
|
|
mvc8PbxT1Slave (216), -- MVC-8 T1 Slave is here
|
|
mvc8ExtAnalog (217), -- MVC-8 with 8 External ports
|
|
mvcE1 (218), -- 8 External ports & 30 Internals
|
|
mvcT1 (219), -- 8 External ports & 24 Internals
|
|
|
|
-- ISDN for Maxcess
|
|
mhsS (220),
|
|
mhsU (221),
|
|
mhsPriE1 (222),
|
|
mhsPriT1 (223),
|
|
|
|
-- Card of MP-2100/4
|
|
hsEthSwitch (224),
|
|
|
|
-- CCS for Maxcess & MPH
|
|
mPriE1FramerCcs (225),
|
|
mPriT1FramerCcs (226),
|
|
mpriE1SlaveCcs (227),
|
|
mpriT1SlaveCcs (228),
|
|
mDualBri (229),
|
|
|
|
-- Voice cards for MP
|
|
vc12EandM (230),
|
|
vc12Fxo (231),
|
|
vc12Fxs (232),
|
|
vc6aEandM (233),
|
|
vc6aFxo (234),
|
|
vc6aFxs (235),
|
|
vc6AgFxo (236),
|
|
vc6AgFxs (237),
|
|
vc6a4LB (238),
|
|
|
|
-- Video card for MP
|
|
vid (239),
|
|
|
|
-- ISDN cards for MP
|
|
hsu12 (240),
|
|
hsu6 (241),
|
|
hss12 (242),
|
|
hss6 (243),
|
|
|
|
-- MPH and MP-2100/4 cards
|
|
hsDp3 (244),
|
|
hsDp6 (245),
|
|
|
|
-- MP-2100/4 card
|
|
hsf1 (246),
|
|
|
|
-- More Hybrid cards + IP cards for MPH
|
|
mhsHyE1 (247), -- 1 Hybrid E1 port
|
|
mhsHyT1 (248), -- 1 Hybrid T1 port
|
|
mhsIp (249), -- 1 Eth port + 1 HS port
|
|
mlIpHs (250), -- 1 Eth port + 3 HS ports
|
|
mlHybIpE1 (251), -- 1 Eth port + 1 HS port + 1 E1
|
|
mlHybIpT1 (252), -- 1 Eth port + 1 HS port + 1 T1
|
|
|
|
-- VOIP cards for MPH & MX
|
|
mvg1Lan (253),
|
|
mvg2Lan (254),
|
|
|
|
-- MP-2100/4 card
|
|
vc4Fxs (255),
|
|
vc4EandM (256),
|
|
vc4Fxo (257),
|
|
hsf2 (258),
|
|
|
|
-- More VOIP cards for MPH
|
|
mvgSwitch4Lan (260),
|
|
|
|
-- SHDSL cards of Megaplex
|
|
msl4E1W2 (261),
|
|
msl4E1W4 (262),
|
|
msl8E1W2 (263),
|
|
msl4E1W2Eth (264),
|
|
msl8E1W2Eth (265),
|
|
asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH)
|
|
asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH)
|
|
asmi54c (268), -- & LRS-102 (ETH only)
|
|
|
|
-- HS cards of Megaplex
|
|
hs6N (271),
|
|
hs12N (272),
|
|
hsNRZ (273),
|
|
|
|
-- Vmux 2100 Enhanced Voice Cards
|
|
evc2E1 (281),
|
|
evc4E1 (282),
|
|
evc2T1 (283),
|
|
evc4T1 (284),
|
|
|
|
-- Vmux-2200 Voice cards
|
|
vc2E1Pri (285),
|
|
vc4E1Pri (286),
|
|
|
|
-- MP Voice cards
|
|
vc4OmniEandM (291),
|
|
vc4OmniWestern (292),
|
|
|
|
-- MP-4100 and/or LRS-102 cards
|
|
clx1 (301),
|
|
clx1GbE (302),
|
|
clx1S155 (303),
|
|
clx1S155GbE (304),
|
|
ml8T1Eth (305),
|
|
ml8E1Eth (306),
|
|
op106cEth (307), -- no external T1
|
|
op108cEth (308), -- no external E1
|
|
op106cEthT1 (309), -- with external T1 (used also by LRS-102)
|
|
op108cEthE1 (310), -- with external E1 (used also by LRS-102)
|
|
op108cEthE1Unbal (311), -- used only by LRS-102
|
|
mpw1 (312),
|
|
op34c (313), -- no external E1
|
|
op25c (314), -- no external T1
|
|
op34cE1 (315), -- with external E1 (used also by LRS-102)
|
|
op25cT1 (316), -- with external T1 (used also by LRS-102)
|
|
m16e1 (317),
|
|
m16t1 (318),
|
|
op108cE1Unbal (319), -- used only by LRS-102
|
|
op108cE1Bal (320), -- used only by LRS-102.
|
|
|
|
-- VFS cards of Megaplex
|
|
vfs24T1 (321),
|
|
vfs30E1 (322),
|
|
vfs48T1 (323), -- 2T1
|
|
vfs60E1 (324), -- 2E1
|
|
|
|
-- MiniCVS cards: This is a placeholder. The following cards exist only in the mdlSInstCardType.
|
|
-- mm4E1 (325),
|
|
-- mm4T1 (326),
|
|
-- mm8E1 (327),
|
|
-- mm8T1 (328),
|
|
-- mm12E1 (329),
|
|
-- mm12T1 (330),
|
|
-- mm16E1 (331),
|
|
-- mm16T1 (332),
|
|
|
|
-- More MP-4100 / LRS-102 SDHSL Cards
|
|
asmi54cE1N (340), -- E1 only New Hardware
|
|
asmi54cN (341), -- ETH only New Hardware
|
|
asmi54cHsN (342), -- V.35 only (HighSpeed) New Hardware
|
|
asmi54cHsAndEthN (343), -- ETH & V.35 (HighSpeed) New Hardware
|
|
|
|
-- MP4100 R3.0 cards
|
|
cl2n (350), -- CL.2
|
|
cl2GbE (351), -- CL.2-GbE
|
|
cl2s622 (352), -- CL.2-622
|
|
cl2s622GbE (353), -- CL.2-622GbE
|
|
cl2s622GbEa (354), -- CL.2-622GbE/a with Advanced ETH features
|
|
cl2GbEa (355), -- CL.2-GbE a with Advanced ETH features
|
|
cl2ds0 (356), -- CL.2 with DS0 cross connect capabilities only
|
|
|
|
-- MP4104 cards (horizontal , low cost hub, lowprofile panels )
|
|
cl2nl (360), -- CL.2
|
|
cl2GbEl (361), -- CL.2-GbE
|
|
cl2s622l (362), -- CL.2-622
|
|
cl2s622GbEl (363), -- CL.2-622GbE
|
|
cl2s622GbEal (364), -- CL.2-622GbE/a with Advanced ETH features
|
|
cl2GbEal (365), -- CL.2-GbE a with Advanced ETH features
|
|
cl2ds0l (366), -- CL.2 with DS0 cross connect capabilities only
|
|
|
|
-- MP4100 R3.1 cards
|
|
mEth6 (370), -- M-ETH6 Card
|
|
mEth8 (371), -- M-ETH8 Card
|
|
|
|
-- TeleProtection Module
|
|
mTp (372), -- TeleProtection module
|
|
|
|
-- MP4100 R3.4 cards
|
|
mT3 (373), -- M-T3 DS3
|
|
|
|
mEthPoe (374), -- M-ETH8 with Power Over Ethernet support.
|
|
|
|
-- MP4100 R4.5 cards
|
|
-- X Module based cards
|
|
mp4mSh16 (381), -- MP-4M-SH-16
|
|
mp4mVs12 (382), -- MP-4M-VS-12
|
|
mp4mVs6s37 (383), -- MP-4M-VS-6/37
|
|
mp4mVs6Bin (384), -- MP-4M-VS-6/BIN
|
|
mp4mVs6E1T1 (385), -- MP-4M-VS-6/E1T1
|
|
mp4mE1T1 (386), -- MP-4M-E1T1
|
|
mp4mT3 (387), -- MP-4M-T3
|
|
mp4mVs6Fxs (388), -- MP-4M-VS6-FXS
|
|
mp4mVs6Fxo (389), -- MP-4M-VS6-FXO
|
|
mp4mVs6Em (390), -- MP-4M-VS6-EM
|
|
mp4mFxsEm (391), -- MP-4M-FXS-EM
|
|
|
|
-- MP4100 R4.7 cards
|
|
mp4mshE1 (392), -- MP-4M-SH-E1
|
|
mp4mshE1Pw (393), -- MP-4M-SH-E1-PW
|
|
mp4mvs16E1Eop (394), -- MP-4M-VS-16E1/EOP
|
|
mp4mvs16T1Eop (395), -- MP-4M-VS-16T1/EOP
|
|
mp4mvs16E1Pw (396), -- MP-4M-VS-16E1/PW
|
|
mp4mvs16T1Pw (397), -- MP-4M-VS-16T1/PW
|
|
mp4mvs6S8E1Pw (398), -- MP-4M-VS-6S/8E1/PW
|
|
mp4mvs6S8T1Pw (399), -- MP-4M-VS-6S/8T1/PW
|
|
|
|
-- Virtual Entity ( x.86 Module )
|
|
mp4mDnfv1 (401), -- MP-4M-DNFV-1 virtual entity (X.86 module)
|
|
|
|
--MP4100 R4.9 cards
|
|
mp4mvsG703 (411), -- MP-4M-VS-G703
|
|
mp4mVs6FxsPwAcr (412), -- MP-4M-VS6-FXS-PW-ACR
|
|
mp4mVs6FxoPwAcr (413), -- MP-4M-VS6-FXO-PW-ACR
|
|
mp4mVs6EmPwAcr (414) -- MP-4M-VS6-EM-PW-ACR
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the type of card assigned to the
|
|
specific slot in the common configuration.
|
|
This object is identical in all the configurations (1..100).
|
|
Only the TmpCnf(255) may have different value.
|
|
The write operation is valid only to the TmpCnfg entry."
|
|
::= { mdlCPrgEntry 3}
|
|
|
|
mdlCNoOfExternPrt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of external ports in the programmed card of the
|
|
specific slot position"
|
|
::= { mdlCPrgEntry 4}
|
|
|
|
mdlCNoOfInternPrt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of internal ports in the programmed card of the
|
|
specific slot position."
|
|
::= { mdlCPrgEntry 5}
|
|
|
|
mdlCWorkMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
standAlone (2),
|
|
integrated (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Working mode of the card.
|
|
The user may configure the card to work in a stand alone mode or integrated
|
|
with the device.
|
|
|
|
Example for use in MHS-IP cards:
|
|
|
|
- standAlone - in this mode, the router works so that data is received
|
|
via the LAN (Eth) port and is transmitted via the WAN (HS) external port
|
|
without going through the MPH device.
|
|
|
|
- integrated - in this mode, the router works so that it is integrated in the MPH
|
|
and routes DLCIs into the device."
|
|
::= { mdlCPrgEntry 6}
|
|
|
|
mdlCDhcpClientEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable the feature of DHCP Client for the selected card."
|
|
::= { mdlCPrgEntry 7}
|
|
|
|
mdlCRdnExists OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether any port of the programmed card is
|
|
configured to be part of a Redundancy/APS pair.
|
|
If at least one port of the programmed card is configured to be
|
|
part of a Redundancy/APS pair, the value will be 'yes'.
|
|
Otherwise, it will be 'no'."
|
|
::= { mdlCPrgEntry 8}
|
|
|
|
mdlCInterfaces OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Octet string which indicates 'present' interfaces in card.
|
|
Each '0' bit stands for non-present interface.
|
|
Each '1' bit stands for present interface.
|
|
|
|
For ASMi54C card of LRS-102 and MP-4100 notPresent interfaces may be:
|
|
- SHDSL Line ID with no wire pairs assigned to it (does not exist in ifTable)
|
|
- PCS without SHDSL Line binded to it, (exist in ifTable, with
|
|
ifOperStatus= notPresent)
|
|
- External DS1 when its LIU is used by an Internal DS1 of the same card
|
|
- Internal DS1 when single bearer is not TDM.
|
|
|
|
In each octet, MS bit represents port 1
|
|
and LS bit represents port 8
|
|
|
|
MSB LSB
|
|
1 0 0 0 1 0 0 0 -- Example: Port # 1 and 5 are present.
|
|
Port 1 2 3 4 5 6 7 8
|
|
|
|
1st Octet (MSB octet) represents SDHSL Lines
|
|
2nd Octet represents PCS
|
|
3rd Octet represents External DS1
|
|
4th Octet represents Internal DS1
|
|
5th and 6th Octets are reserved for future Internal DS1.
|
|
|
|
For OP-108/106 cards of LRS-102 and MP-4100 notPresent interfaces may be:
|
|
- External DS1 when its 'associated' Int-DS1 port is connected to another card
|
|
- Internal DS1 when its 'associated' Ext-DS1 port is connected to another card
|
|
(Both may be 'present' when inter-connected).
|
|
1st Octet represents External DS1
|
|
2nd Octet represents Internal DS1
|
|
Bit representation, same as for ASMi-54C card.
|
|
"
|
|
::= { mdlCPrgEntry 9 }
|
|
|
|
|
|
|
|
--
|
|
-- Compressed information.
|
|
--
|
|
-- Specially for RadView management station
|
|
--
|
|
mdlCmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { cmprMdlGen 1 }
|
|
|
|
mdlCmprEntry OBJECT-TYPE
|
|
SYNTAX MdlCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { mdlCmprTypIdx, mdlCmprCnfgIdx ,mdlCmprVersion,mdlCmprSltIdx }
|
|
::= {mdlCmprTable 1}
|
|
|
|
MdlCmprEntry ::=
|
|
SEQUENCE {
|
|
mdlCmprTypIdx Integer32,
|
|
mdlCmprCnfgIdx Integer32,
|
|
mdlCmprVersion Integer32,
|
|
mdlCmprSltIdx INTEGER,
|
|
mdlCmprObj OCTET STRING
|
|
}
|
|
|
|
mdlCmprTypIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Type of the Compressed being
|
|
referred."
|
|
::= { mdlCmprEntry 1}
|
|
|
|
mdlCmprCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the configuration to which the
|
|
Compressed information is related."
|
|
::= { mdlCmprEntry 2}
|
|
|
|
mdlCmprVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the version of the internal format
|
|
of the Compressed data"
|
|
::= { mdlCmprEntry 3}
|
|
|
|
mdlCmprSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
psA (1),
|
|
psB (2),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number of the slot
|
|
position where the card is inserted.
|
|
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
|
|
are not valid."
|
|
::= { mdlCmprEntry 4}
|
|
|
|
mdlCmprObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the compressed information itself."
|
|
::= { mdlCmprEntry 5}
|
|
|
|
-- Compressed Alarm table at Card level
|
|
-- The only way of reading this table is by the command 'GET NEXT'
|
|
|
|
mdlAlarmsCmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlAlarmsCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= {cmprMdlGen 2}
|
|
|
|
mdlAlarmsCmprEntry OBJECT-TYPE
|
|
SYNTAX MdlAlarmsCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {mdlAlarmsCmprVersion,
|
|
mdlAlarmsCmprAlarmSlot,mdlAlarmsCmprAlarmIdx}
|
|
::= {mdlAlarmsCmprTable 1}
|
|
|
|
MdlAlarmsCmprEntry ::=
|
|
SEQUENCE {
|
|
mdlAlarmsCmprVersion Integer32,
|
|
mdlAlarmsCmprAlarmSlot Integer32,
|
|
mdlAlarmsCmprAlarmIdx Integer32,
|
|
mdlAlarmsCmprObj OCTET STRING
|
|
}
|
|
|
|
mdlAlarmsCmprVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the version of the internal format
|
|
of the Compressed data"
|
|
::= { mdlAlarmsCmprEntry 1}
|
|
|
|
mdlAlarmsCmprAlarmSlot OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the desired slot position.
|
|
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
|
|
are not valid."
|
|
::= { mdlAlarmsCmprEntry 2}
|
|
|
|
mdlAlarmsCmprAlarmIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify an entry in the alarm status table
|
|
of the agent."
|
|
::= { mdlAlarmsCmprEntry 3}
|
|
|
|
mdlAlarmsCmprObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the compressed information itself."
|
|
::= { mdlAlarmsCmprEntry 4}
|
|
|
|
|
|
--
|
|
-- Wan port status general information
|
|
--
|
|
prtSInstTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSInstEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { statPrtGen 1 }
|
|
|
|
prtSInstEntry OBJECT-TYPE
|
|
SYNTAX PrtSInstEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtSInstSltIdx, prtSInstPrtIdx }
|
|
::= { prtSInstTable 1}
|
|
|
|
PrtSInstEntry ::= SEQUENCE {
|
|
prtSInstSltIdx INTEGER,
|
|
prtSInstPrtIdx Integer32,
|
|
prtSInstPrtType INTEGER,
|
|
prtSInstIfIndex Integer32,
|
|
prtSActiveStatus INTEGER,
|
|
prtSAlrStatus INTEGER,
|
|
prtSMaskedAlrStat INTEGER,
|
|
prtSClearAlrCmd INTEGER,
|
|
prtSTestMask Integer32,
|
|
-- prtSTstStatus INTEGER,
|
|
prtSTstCmd INTEGER,
|
|
prtSTstDuration Integer32,
|
|
prtSBertClrCmd INTEGER,
|
|
prtSBertTstRslt Integer32,
|
|
prtSInterfaceType DisplayString,
|
|
prtSParamStatus OCTET STRING,
|
|
prtSTestMaskXp OCTET STRING,
|
|
prtSRdnStatus INTEGER
|
|
}
|
|
|
|
prtSInstSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify the
|
|
slot where the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io(16) are not valid.
|
|
For the Vmux2100 Main Board clA (3) is used."
|
|
::= { prtSInstEntry 1}
|
|
|
|
prtSInstPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify a port
|
|
in a specific card.
|
|
The valid ports depend on the installed card:
|
|
the valid external ports (interfaces) are (1..mdlCNoOfExternPrt) if any,
|
|
and the valid internal ports are (101..100+mdlCNoOfInternPrt) if any.
|
|
Generally, for MP-2100/2200: exPrt1 (1) .. exPrt16 (16),inPrt1(101)
|
|
.. inPrt48 (148)
|
|
|
|
For the Vmux-2100 device:
|
|
This index will have values of 1...4 for the physical ports & values
|
|
of ifIndex for the bundles.
|
|
|
|
For other products, see product's spec."
|
|
::= { prtSInstEntry 2}
|
|
|
|
prtSInstPrtType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
external (2),
|
|
internal (3),
|
|
highSpeedV35 (4),
|
|
highSpeedV24 (5),
|
|
highSpeedV36 (6),
|
|
highSpeedX21 (7),
|
|
highSpeedG703 (8),
|
|
highSpeedDDS (9),
|
|
lowSpeed (10),
|
|
voice (11),
|
|
cl (12),
|
|
isdns (13),
|
|
isdnu (14),
|
|
ethernet (15),
|
|
voiceS0 (16),
|
|
voiceU (17),
|
|
voiceQsigS (18),
|
|
voiceQsigU (19)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute describes the type of the designated port.
|
|
In MX 3000 only external & internal options are used.
|
|
All the other options are only for MX 30/300 which need special handling.
|
|
In order to support interface types in MX 3000, return an ascii string for
|
|
prtSInterfaceType in this table or support the general RAD value of
|
|
physicalConnector.
|
|
|
|
External port - is a port with a physical connector.
|
|
Internal port - might be of two types:
|
|
a) A composite port which collects a few external ports
|
|
data into a common bandwidth (usually routed through
|
|
DS1 link)
|
|
b) A port which gets only part of the external ports
|
|
(usually a few DS0's)
|
|
The following types are used when all ports are external/
|
|
internal and the connector/interface type is necessary
|
|
(for example, stand-alone units):
|
|
High Speed port types
|
|
Low Speed port types
|
|
Voice port types, CL port types.
|
|
|
|
ISDN Voice in MX 30/300 Phase 4: voiceS0 (16), voiceU (17) should be used.
|
|
ISDN Voice in MX 30/300 Phase 5: voiceQsigS(18), voiceQsigU (19) should be used."
|
|
::= { prtSInstEntry 3}
|
|
|
|
prtSInstIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the unique interface number
|
|
assigned to the port. The specific interface of this
|
|
attribute is the same as the interface identified by the
|
|
value of ifindex in MIB-II.If there is no interface for
|
|
the specific prtIdx the value will be '7fffffff'h."
|
|
::= { prtSInstEntry 4}
|
|
|
|
prtSActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
notUsed (2),
|
|
offLine (3),
|
|
onLine (4),
|
|
offLineRedundancy (5),
|
|
onLineRedundancy (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute describes the activity status of the port.
|
|
unknown(1) indicates that the information is not supported.
|
|
notUsed(2) indicates that the ch is not connected according
|
|
to the active config.
|
|
offLine(3) indicates that the ch is down (not working)
|
|
because of any problem.
|
|
onLine(4) indicates that the ch is up (working)
|
|
offLineRedundancy(5) indicates that the ch is down, because
|
|
it is redundant port.
|
|
onLineRedundancy(6) indicates that the ch is up, and it is
|
|
the active link"
|
|
::= { prtSInstEntry 5}
|
|
|
|
prtSAlrStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the alarm state in the port(ch) agent level.
|
|
This attribute will be set to:
|
|
critical(7) - when there is at least one active (state ON)
|
|
critical alarm,
|
|
otherwise it will be set to
|
|
major(5) - when there is at least one active (state ON)
|
|
major alarm,
|
|
otherwise it will be set to
|
|
minor(4) - if there is at least one active (state ON) minor
|
|
alarm,
|
|
otherwise it will be set to
|
|
warning(6) - if there is at least one active (state ON)
|
|
warning alarm,
|
|
otherwise it will be set to
|
|
event(3) - if there was at least one alarm event (including
|
|
state on,off events) since the last clear operation."
|
|
::= { prtSInstEntry 6}
|
|
|
|
prtSMaskedAlrStat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the alarm state in the port(ch) agent level,
|
|
including Masked alarms.
|
|
This attribute will be set to:
|
|
critical(7) - when there is at least one active (state ON)
|
|
critical alarm,
|
|
otherwise it will be set to
|
|
major(5) - when there is at least one active (state ON)
|
|
major alarm,
|
|
otherwise it will be set to
|
|
minor(4) - if there is at least one active (state ON) minor
|
|
alarm,
|
|
otherwise it will be set to
|
|
warning(6) - if there is at least one active (state ON)
|
|
warning alarm,
|
|
otherwise it will be set to
|
|
event(3) - if there was at least one alarm event (including
|
|
state on,off events) since the last clear operation."
|
|
::= {prtSInstEntry 7}
|
|
|
|
prtSClearAlrCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to on(3) enforces a clear operation
|
|
of the alarm status events in the given port. The clear
|
|
operation will not be applied for masked/inverted alarms."
|
|
::= { prtSInstEntry 8}
|
|
|
|
prtSTestMask OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a mask which indicates which tests from the
|
|
'prtSTstCmd' list are allowed for the requested port.
|
|
If a specific test is allowed, its respective bit
|
|
will be SET in the mask :
|
|
|
|
TEST BIT
|
|
----------- ---
|
|
local-loop 1
|
|
remote-loop 2
|
|
loc-and-rem-main-loops 3
|
|
remote-analog-loop 4
|
|
remote-digital-loop 5
|
|
rem-loop-on-ext-unit 6
|
|
bert 7
|
|
tone-injection 8
|
|
dlci local-loop 9
|
|
all dlci local-loop 10
|
|
dlci remote-loop 11
|
|
all dlci remote-loop 12
|
|
bert-and-rem-loop-on-rem-unit 13
|
|
rem-loop-on-rem-unit 14
|
|
block 15
|
|
backward-tone-inject 16
|
|
llb 17
|
|
rlb 18
|
|
|
|
ft1Enable 21
|
|
lbbd 22 --for 2B+D
|
|
lb1 23 --for B1
|
|
lb2 24 --for B2
|
|
llb-on-rem-unit 25
|
|
bert-on-rem-unit 26
|
|
bert-on-rem-and-llb-on-rem-unit 27
|
|
local-and-bert-on-rem-unit 28
|
|
local-loop-on-rem-unit 29
|
|
localBert 30 --towards IO ports
|
|
test-per-TS 31
|
|
|
|
e.g : If the return value is 3 -> 0000000000000011 ->
|
|
Bits 1 & 2 are set -> the allowed tests are :
|
|
local-loop
|
|
remote-loop
|
|
"
|
|
::= { prtSInstEntry 9}
|
|
|
|
-- prtSTstStatus OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- {
|
|
-- off(2),
|
|
-- on (3)
|
|
-- }
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This attribute will be set to on(3) when there is at least
|
|
-- one test in progress in the port, otherwise the value
|
|
-- will be off(2)."
|
|
-- ::= { prtSInstEntry 10}
|
|
--
|
|
|
|
|
|
prtSTstCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
localLoop (2),
|
|
remoteLoop (3),
|
|
locAndRemMainLoops (4),
|
|
remoteAnalogLoop (5),
|
|
remoteDigitalLoop (6),
|
|
remLoopOnExtUnit (7),
|
|
bert (8),
|
|
toneInjection (9),
|
|
dlciLocalLoop (10),
|
|
allDlciLocalLoop (11),
|
|
dlciRemoteLoop (12),
|
|
allDlciRemoteLoop (13),
|
|
extInitLocalLoop (14),
|
|
bertAndRemLoopOnRemUnit (15),
|
|
remLoopOnRemUnit (16),
|
|
block (17),
|
|
backwardToneInject (18),
|
|
llb (19),
|
|
rlb (20),
|
|
ft1Enable (21),
|
|
lbbd (22), --for 2B+D
|
|
lb1 (23), --for B1
|
|
lb2 (24), --for B2
|
|
llbOnRemUnit (25),
|
|
bertOnRemUnit (26),
|
|
bertOnRemAndLlbOnRemUnit (27),
|
|
localAndBertOnRemUnit(28),
|
|
localLoopOnRemUnit (29),
|
|
localBert (30),
|
|
testPerTS (31),
|
|
csuLoopAndBert (32),
|
|
dsuLoopAndBert (33),
|
|
remoteOcuLoopAndBert (34),
|
|
remoteCsuLoopAndBert (35),
|
|
remoteDsuLoopAndBert (36)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to any of the above values will
|
|
initiate a test on the specific port if the operation is
|
|
legal. If the operation is not legal, the mux will ignore
|
|
the operation.
|
|
testPerTS(31) - when this test is selected, the selection of tests
|
|
for each TS is done via the prtExPh1MlTsTest object.
|
|
If a test time out is needed, the test will be set with a
|
|
default timeout of 2 minutes until the user will set the
|
|
parameter 'prtSTstDuration' to the required time out.
|
|
If no time out is needed , the test will be set with infinite
|
|
timeout until the user will set the parameter
|
|
'prtSTstDuration' to the required time out."
|
|
::= { prtSInstEntry 10}
|
|
|
|
prtSTstDuration OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the maximum duration of executing
|
|
a test on the specific port. This entry applies to all the
|
|
test operations. The resolution will be a minute, and the
|
|
maximum duration is limited to 30 minutes.
|
|
|
|
For Vmux devices, the values are in seconds.
|
|
|
|
A zero value specifies no time limitation.
|
|
When the test isn't active, the agent initiates this object to
|
|
2 when the duration is needed and to 0 if its not required.
|
|
The user should set this parameter after setting the
|
|
'prtSTstCmd' parameter."
|
|
::= { prtSInstEntry 11}
|
|
|
|
prtSBertClrCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute initiates bert count clear operation.
|
|
It is valid only when bert test is active on the specific
|
|
port."
|
|
::= { prtSInstEntry 12}
|
|
|
|
prtSBertTstRslt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the number of Bit Error Rate
|
|
indicated during the BERT operation.
|
|
It is valid only when bert test is active on the specific
|
|
port."
|
|
::= { prtSInstEntry 13}
|
|
|
|
prtSInterfaceType OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique HW interface type of the
|
|
selected port."
|
|
::= { prtSInstEntry 14}
|
|
|
|
prtSParamStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates Status of parameters specific to the
|
|
selected port.
|
|
- For a port that has no special status or is supported
|
|
by prtSExHsfStatTable - 1 Octet: 00hex
|
|
|
|
- For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet :
|
|
Bit 7 (MSB)..Bit 2 = 0 (NA)
|
|
Bit 1: Tx Signaling '1'=On ; '0'=Off
|
|
Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off
|
|
|
|
- For VC-2/R2(FXS) external ports - 1 Octet :
|
|
Bit - 7 6 5 4 3 2 1 0
|
|
|_| |_________|
|
|
Call Call State
|
|
Direction
|
|
|
|
Bit 7 (MSB) and Bit 6 : Call Direction
|
|
00 - Incoming
|
|
01 - Outgoing
|
|
Bit 5..Bit 0: Call State
|
|
000000 - Idle
|
|
000001 - Seized
|
|
000010 - Both-Way Conflict
|
|
000011 - Seizure Ack
|
|
000100 - Answered
|
|
000101 - Clear Backward
|
|
000110 - Clear Forward
|
|
000111 - Blocked
|
|
001000 - Fault
|
|
001001 - Fault 3
|
|
001010 - Fault 4
|
|
001011 - Fault 5
|
|
001100 - Fault 6
|
|
001101 - Fault 7
|
|
|
|
- For ML-20 external port - 3 Octets :
|
|
- 1 MS Octet will represent the Real Rate used:
|
|
Bit - 7 6 5 4 3 2 1 0
|
|
|___| |_______|
|
|
spare Rate
|
|
|
|
Valid values: 0..31, meaning 0..31x64Kbps
|
|
Invalid values: 32..255.
|
|
- 2 LS Octets will represent the Status of 7 Control
|
|
Signals:
|
|
Signal - --- CTS DSR DCD RJ TM DTR RTS
|
|
Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
|
|
Octet - 2 3 (LS)
|
|
'---' will always have the value 00
|
|
Rest of the Signals (2 bits each) can have the following
|
|
values:
|
|
00=NA ; 01=unused ; 10=Off ; 11=On
|
|
|
|
- For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet
|
|
Bit - 7 6 5 4 3 2 1 0
|
|
|___________|
|
|
spare Mode of Operation
|
|
|
|
Mode of Operation: '1'=Central ; '0'=Remote
|
|
|
|
- For ACM external port - 1 Octet
|
|
Bit - 7 6 5 4 3 2 1 0
|
|
|_________|
|
|
spare Alarm State
|
|
|
|
Alarm State: according to bits 1,0:
|
|
00=NA ; 01=unused ; 10=Off ; 11=On
|
|
|
|
- For HS-U/1 external port - 1 Octet
|
|
Bit 7 6 5 4 3 2 1 0 LSB
|
|
|________| |__| |__|
|
|
spare modem sync
|
|
|
|
modem: 00 = other sync: 00 = not sync
|
|
01 = unknown 01 = sync
|
|
10 = ASMi-31/2 10 = reserved
|
|
11 = reserved 11 = reserved
|
|
|
|
- For MTML-2/4 external ports, ML-8 externalports, ML-IP (MTML-IP)
|
|
internal ports and MTML-E2 internal ports - 1 Octet :
|
|
Bit 7 6 5 4 3 2 1 0 LSB
|
|
|
|
|
BERT State
|
|
BERT State (Bit 0):
|
|
0 = OFF (BERT is not running on this port or any of its TSs/Bits)
|
|
1 = ON (BERT is running on this port OR on one of its TSs/Bits)
|
|
|
|
- For ML-20N external ports - 4 Octets
|
|
- 1 MS Octet will represent the Actual Link Rate:
|
|
Bit - 7 6 5 4 3 2 1 0
|
|
|_| |_________|
|
|
spare Rate
|
|
|
|
Valid values: 0..34, meaning:
|
|
0..32 = (0..32)x64Kbps
|
|
33 = Invalid Rate
|
|
34 = not applicable (when Rate is not Auto)
|
|
35 = 0 Kbps
|
|
|
|
Invalid values: 36..255.
|
|
|
|
- 2 middle Octets will represent the Status of 4 Control
|
|
Signals:
|
|
- LS Octet - Bits 3-0: RTS/C (Command, for X.21 interface)
|
|
Bits 7-4: DCD/I (Indication for X.21 interface)
|
|
- MS Octet - Bits 3-0: DTR
|
|
Bits 7-4: DSR
|
|
Each 4 Bits are divided as follows:
|
|
- 2 MS bits: DCE
|
|
- 2 LS bits: DTE
|
|
For each 2 bits (DCE/DTE):
|
|
00=NA ; 01=unused ; 10=Off ; 11=On.
|
|
|
|
|
|
- LS Octet: (as for MTML-2):
|
|
Bit 7 6 5 4 3 2 1 0 LSB
|
|
|
|
|
BERT State
|
|
BERT State (Bit 0):
|
|
0 = OFF (BERT is not running on this port or any of its TSs/Bits)
|
|
1 = ON (BERT is running on this port OR on one of its TSs/Bits)
|
|
|
|
|
|
- For MP-2100/2200 MSL-4/E1, MSL-8/E1 External ports - 3 Octets
|
|
- MS octet: far-end modem channel interface
|
|
- Middle octet: Material (plastic/metal), far-end modem type,
|
|
synchronization with far-end modem
|
|
- LS octet: BERT state (at port/TS/Bit level)
|
|
|
|
- MS octet: 0000 0000 = no interface
|
|
0000 0001 = db15 (X21)
|
|
0000 0010 = IR-IP
|
|
0000 0011 = IR-ETH-Q
|
|
0000 0100 = V35
|
|
0000 0101 = ETH-RJ45
|
|
0000 0110 = G703
|
|
0000 0111 = db25 (RS530)
|
|
0000 1000 = ETH-BNC
|
|
0000 1001 = E1(Balanced)
|
|
0000 1010 = E1(Unbalanced)
|
|
0000 1011 = IR-ETH-QN
|
|
Rest of the combinations: reserved
|
|
|
|
- Middle octet:
|
|
|
|
Bit 7 6 5 4 3 2 1 0 LSB
|
|
| |___________| |__|
|
|
Box material modem sync
|
|
|
|
|
|
Box material modem: 00000 = other sync: 00 = not sync
|
|
(for ASMi-52 SA) 00001 = unknown 01 = sync
|
|
0=metal 00010 = reserved 10 = reserved
|
|
1=plastic 00011 = reserved 11 = reserved
|
|
00100 = reserved
|
|
00101 = reserved
|
|
00110 = ASMi-52 SA/2W/Slave
|
|
00111 = ASMi-52 SA/2W/Master
|
|
01000 = ASMi-52/CQ card of LRS-24
|
|
01001 = ASMi-52/CD card of LRS-24
|
|
01010 = D16GSDSL card of DXC-3000
|
|
01011 = LRS-52
|
|
01100 = FCD-IP
|
|
01101 = FCD-IPM
|
|
01110 = D8SL card of DXC-30
|
|
01111 = ASMi-52A
|
|
10000 = MP card (SHDSL)
|
|
10001 = ASMi-52L
|
|
Rest = reserved
|
|
|
|
- LS Octet: (as for MTML-2):
|
|
Bit 7 6 5 4 3 2 1 0 LSB
|
|
|
|
|
BERT State
|
|
BERT State (Bit 0):
|
|
0 = OFF (BERT is not running on this port or any of its TSs)
|
|
1 = ON (BERT is running on this port OR on one of its TSs)
|
|
|
|
- For MP-4100 MSL card Links - 4 Octets
|
|
- MS octet: far-end modem DTE2 interface (same as for MP-2100 MSL cards)
|
|
- after MS octet: far-end modem DTE1 interface (same as for MP-2100 MSL cards)
|
|
- before LS octet: Material (plastic/metal), far-end modem type,
|
|
synchronization with far-end modem (same as for MP-2100 MSL cards)
|
|
- LS octet: BERT state (at port/TS/Bit level)- same as for MP-2100 MSL cards
|
|
|
|
- For MP-4100, LRS-102 OP-108/106 , OP-34/25 Links - 3 Octets
|
|
- MS octet: Far-End PS type and state
|
|
- Middle octet: synchronization with Far-End device
|
|
- LS octet: BERT state (at port/TS level) - same as for MP-2100 MSL cards
|
|
|
|
- MS octet:
|
|
Bit 7 6 5 4 3 2 1 0 LSB
|
|
|__| |__| |__| |__|
|
|
PS-A PS-A PS-B PS-B
|
|
PS Type PS State PS Type PS State
|
|
00=None 00=None
|
|
01=AC-DC 01=OK
|
|
10=DC 10=Fail
|
|
11=AC
|
|
|
|
- Middle octet:
|
|
|
|
Bit 7 6 5 4 3 2 1 0 LSB
|
|
|__|
|
|
sync:
|
|
00 = not sync
|
|
01 = sync
|
|
10 = reserved
|
|
11 = reserved
|
|
Rest = reserved
|
|
"
|
|
::= { prtSInstEntry 15}
|
|
|
|
prtSTestMaskXp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is an Expanded test mask of the prtSTestMask object.
|
|
The prtSTestMask object reached its maximum, being an Integer with 32 bits.
|
|
This object indicates which tests from the 'prtSTstCmdXP' list are
|
|
allowed for the selected port.
|
|
If a specific test is allowed, its respective bit will be SET
|
|
in the mask :
|
|
|
|
TEST BIT
|
|
----------- ---
|
|
local-loop 1
|
|
remote-loop 2
|
|
loc-and-rem-main-loops 3
|
|
remote-analog-loop 4
|
|
remote-digital-loop 5
|
|
rem-loop-on-ext-unit 6
|
|
bert 7
|
|
tone-injection 8
|
|
dlci local-loop 9
|
|
all dlci local-loop 10
|
|
dlci remote-loop 11
|
|
all dlci remote-loop 12
|
|
bert-and-rem-loop-on-rem-unit 13
|
|
rem-loop-on-rem-unit 14
|
|
block 15
|
|
backward-tone-inject 16
|
|
llb 17
|
|
rlb 18
|
|
|
|
ft1Enable 21
|
|
lbbd 22 --for 2B+D
|
|
lb1 23 --for B1
|
|
lb2 24 --for B2
|
|
llb-on-rem-unit 25
|
|
bert-on-rem-unit 26
|
|
bert-on-rem-and-llb-on-rem-unit 27
|
|
local-and-bert-on-rem-unit 28
|
|
local-loop-on-rem-unit 29
|
|
localBert 30 --towards IO ports
|
|
test-per-TS 31
|
|
csuLoopAndBert 32
|
|
dsuLoopAndBert 33
|
|
remoteOcuLoopAndBert 34
|
|
remoteCsuLoopAndBert 35
|
|
remoteDsuLoopAndBert 36
|
|
|
|
e.g : If the return value is 00000003 hex ->
|
|
Bits 1 & 2 are set -> the allowed tests are :
|
|
local-loop
|
|
remote-loop "
|
|
::= { prtSInstEntry 16}
|
|
|
|
prtSRdnStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noRdn (1),
|
|
offline(2),
|
|
online (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Redundancy Status of this port.
|
|
noRdn - this port is not part of a Redundancy pair/group.
|
|
offline - this port is offline from Redundancy point of view.
|
|
online - this port is online from Redundancy point of view."
|
|
::= { prtSInstEntry 17}
|
|
|
|
|
|
|
|
|
|
prtSAlrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The list of port agent alarms."
|
|
::= { statPrtGen 2 }
|
|
|
|
prtSAlrEntry OBJECT-TYPE
|
|
SYNTAX PrtSAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtSAlrSltIdx, prtSAlrPrtIdx, prtSAlrIdx}
|
|
::= { prtSAlrTable 1}
|
|
|
|
PrtSAlrEntry ::=
|
|
SEQUENCE {
|
|
prtSAlrSltIdx INTEGER,
|
|
prtSAlrPrtIdx Integer32,
|
|
prtSAlrIdx Integer32,
|
|
prtSAlrCodeDescription DisplayString,
|
|
prtSAlrCode Integer32,
|
|
prtSAlrSeverity INTEGER,
|
|
prtSAlrState INTEGER,
|
|
prtSAlrCounter Integer32,
|
|
prtSAlrMask INTEGER,
|
|
prtSAlrInvert INTEGER,
|
|
prtSAlrCardType INTEGER
|
|
}
|
|
|
|
prtSAlrIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify an entry in the alarm status table.
|
|
Users should use the get next function to read this table because
|
|
the indexes are not consecutive"
|
|
::= { prtSAlrEntry 1}
|
|
|
|
prtSAlrSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
psA (1),
|
|
psB (2),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique identifier of the slot
|
|
where the card is inserted.
|
|
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16)
|
|
are not valid.
|
|
For the Vmux2100 Main Board clA (3) is used."
|
|
::= { prtSAlrEntry 2}
|
|
|
|
prtSAlrPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique identifier of the port
|
|
the alarm applies to.
|
|
All the values are valid. No alarms exist for a port
|
|
which does not exist.
|
|
Valid valuesfor MP-2100/2200: exPrt1 (1) .. exPrt16 (16) ,
|
|
inPrt1 (101) .. inPrt48 (148),
|
|
IP Bundles.
|
|
For other products, see product's spec."
|
|
::= { prtSAlrEntry 3}
|
|
|
|
prtSAlrCodeDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is a full text description of the alarm.
|
|
The alarm description includes the following information:
|
|
alarm code, alarm text, alarm severity, Masked or Inverted
|
|
flag and counter."
|
|
::= { prtSAlrEntry 4}
|
|
|
|
prtSAlrCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A code identifying the alarm of an entry in the alarm status
|
|
table at port level."
|
|
::= { prtSAlrEntry 5 }
|
|
|
|
prtSAlrSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the alarm."
|
|
::= { prtSAlrEntry 6 }
|
|
|
|
prtSAlrState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of the alarm."
|
|
::= { prtSAlrEntry 7 }
|
|
|
|
prtSAlrCounter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter - how many times the alarm occured since last
|
|
clear operation.
|
|
ON and OFF Alarm will be counted separately."
|
|
::= { prtSAlrEntry 8 }
|
|
|
|
prtSAlrMask OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm mask : on/off."
|
|
::= { prtSAlrEntry 9 }
|
|
|
|
prtSAlrInvert OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm invert : on/off."
|
|
::= { prtSAlrEntry 10 }
|
|
|
|
prtSAlrCardType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
--
|
|
-- General types
|
|
--
|
|
unknown (1),
|
|
empty (2),
|
|
--
|
|
-- Power Supply Modules
|
|
--
|
|
ps (17),
|
|
|
|
|
|
--
|
|
-- Cl Modules
|
|
--
|
|
cl1 (20),
|
|
cl1Clk (26), --CL1 with Station Clock (for LRS102)
|
|
|
|
|
|
|
|
-- VF cards of Megaplex
|
|
vf24T1 (62),
|
|
vf30E1 (63),
|
|
vf48T1 (64),
|
|
vf60E1 (65),
|
|
--
|
|
-- TDM Cards
|
|
--
|
|
vc8EandM (74),
|
|
vc8Fxo (75),
|
|
vc8Fxs (76),
|
|
vc16EandM (77),
|
|
vc16Fxo (78),
|
|
vc16Fxs (79),
|
|
|
|
ml8T1 (134),
|
|
ml8E1 (135),
|
|
|
|
hsr (156),
|
|
|
|
ls12 (159),
|
|
|
|
ls6n (180),
|
|
|
|
hsEthSwitch (224),
|
|
|
|
hsu12 (240),
|
|
hsu6 (241),
|
|
|
|
vc4Fxs (255),
|
|
vc4EandM (256),
|
|
vc4Fxo (257),
|
|
|
|
msl4E1W2 (261),
|
|
|
|
msl8E1W2 (263),
|
|
msl4E1W2Eth (264),
|
|
msl8E1W2Eth (265),
|
|
asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH)
|
|
asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH)
|
|
asmi54c (268), -- & LRS-102 (ETH only)
|
|
|
|
hs6N (271),
|
|
hs12N (272),
|
|
|
|
-- MP-4100 (and LRS-102) cards
|
|
clx1 (301),
|
|
clx1GbE (302),
|
|
clx1S155 (303),
|
|
clx1S155GbE (304),
|
|
ml8T1Eth (305),
|
|
ml8E1Eth (306),
|
|
op106cEth (307), --no external T1
|
|
op108cEth (308), --no external E1
|
|
op106cEthT1 (309), --with external T1 (used also by LRS-102)
|
|
op108cEthE1 (310), --with external E1 (used also by LRS-102)
|
|
op108cEthE1Unbal(311), --used only by LRS-102
|
|
mpw1 (312),
|
|
|
|
-- VFS cards of Megaplex
|
|
vfs24T1 (321),
|
|
vfs30E1 (322),
|
|
vfs48T1 (323), --2T1
|
|
vfs60E1 (324) --2E1
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the type of card installed
|
|
in the specific slot position. The enumeration is according
|
|
to mdlSInstCardType."
|
|
::= { prtSAlrEntry 11 }
|
|
|
|
--
|
|
-- Statistics of Ports
|
|
--
|
|
|
|
--statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3}
|
|
|
|
--prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1}
|
|
--prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2}
|
|
--prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3}
|
|
--prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4}
|
|
|
|
|
|
--prtFrStatis - Port Statistics for (FR) Frame Relay protocol
|
|
|
|
prtFrStatisTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtFrStatisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is applicable only for an active port running an
|
|
FR protocol ."
|
|
::= { prtFrStatis 1}
|
|
|
|
prtFrStatisEntry OBJECT-TYPE
|
|
SYNTAX PrtFrStatisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtFrStatisSltIdx, prtFrStatisPrtIdx, prtFrStatisInvIdx}
|
|
::= { prtFrStatisTable 1}
|
|
|
|
PrtFrStatisEntry ::=
|
|
SEQUENCE {
|
|
prtFrStatisSltIdx INTEGER,
|
|
prtFrStatisPrtIdx INTEGER,
|
|
prtFrStatisInvIdx INTEGER,
|
|
prtFrTimeElapsed Integer32,
|
|
prtFrRxTotalFrames Counter32,
|
|
prtFrTxTotalFrames Counter32,
|
|
prtFrRxTotalBytes Counter32,
|
|
prtFrTxTotalBytes Counter32,
|
|
prtFrRxMngFrames Counter32,
|
|
prtFrTxMngFrames Counter32,
|
|
prtFrRxDeFrames Counter32,
|
|
prtFrTxDeFrames Counter32,
|
|
prtFrRxDcrdCongDeFr Counter32,
|
|
prtFrTxDcrdCongDeFr Counter32,
|
|
prtFrRxDcrdCongAllFr Counter32,
|
|
prtFrTxDcrdCongAllFr Counter32,
|
|
prtFrRxFecn Counter32,
|
|
prtFrTxFecn Counter32,
|
|
prtFrRxBecn Counter32,
|
|
prtFrTxBecn Counter32,
|
|
prtFrRxBeViol Counter32,
|
|
prtFrTxBeViol Counter32,
|
|
prtFrRxBcViol Counter32,
|
|
prtFrTxBcViol Counter32
|
|
}
|
|
|
|
prtFrStatisSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the module is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
|
|
For stand-alone units this index will be notApplicable (255)."
|
|
::= { prtFrStatisEntry 1}
|
|
|
|
prtFrStatisPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number."
|
|
::= { prtFrStatisEntry 2}
|
|
|
|
prtFrStatisInvIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
currentInv (1),
|
|
last (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Interval of 15 min. for which the following statistics
|
|
counters are applicable."
|
|
::= { prtFrStatisEntry 3}
|
|
|
|
prtFrTimeElapsed OBJECT-TYPE
|
|
SYNTAX Integer32 (0..899)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of seconds that have elapsed since the
|
|
beginning of the current error-measurement interval.
|
|
This object is applicable mainly for the current interval.
|
|
For other interval:
|
|
- if data is available: value will be 899.
|
|
- if data is not available: value will be 0."
|
|
::= { prtFrStatisEntry 4 }
|
|
|
|
prtFrRxTotalFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of frames received by this port during the
|
|
selected interval."
|
|
::= { prtFrStatisEntry 5 }
|
|
|
|
prtFrTxTotalFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of frames sent by this port during the
|
|
selected interval."
|
|
::= { prtFrStatisEntry 6 }
|
|
|
|
prtFrRxTotalBytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of bytes received by this port during the
|
|
selected interval."
|
|
::= { prtFrStatisEntry 7 }
|
|
|
|
prtFrTxTotalBytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of bytes sent by this port during the
|
|
selected interval."
|
|
::= { prtFrStatisEntry 8 }
|
|
|
|
prtFrRxMngFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The management number of frames received by this port
|
|
during the selected interval."
|
|
::= { prtFrStatisEntry 9 }
|
|
|
|
prtFrTxMngFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The management number of frames sent by this port during the
|
|
selected interval."
|
|
::= { prtFrStatisEntry 10 }
|
|
|
|
prtFrRxDeFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of De frames received by this port during the
|
|
selected interval."
|
|
::= { prtFrStatisEntry 11 }
|
|
|
|
prtFrTxDeFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of De frames sent by this port during the
|
|
selected interval."
|
|
::= { prtFrStatisEntry 12 }
|
|
|
|
prtFrRxDcrdCongDeFr OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of De frames discarded due to congestion,
|
|
received by this port during the selected interval."
|
|
::= { prtFrStatisEntry 13 }
|
|
|
|
prtFrTxDcrdCongDeFr OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of De frames discarded due to congestion,
|
|
sent by this port during the selected interval."
|
|
::= { prtFrStatisEntry 14 }
|
|
|
|
prtFrRxDcrdCongAllFr OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All the frames discarded due to congestion,
|
|
received by this port during the selected interval."
|
|
::= { prtFrStatisEntry 15 }
|
|
|
|
prtFrTxDcrdCongAllFr OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All the frames discarded due to congestion,
|
|
sent by this port during the selected interval."
|
|
::= { prtFrStatisEntry 16 }
|
|
|
|
prtFrRxFecn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of frames received by this port during the
|
|
selected interval, indicating forward congestion."
|
|
::= { prtFrStatisEntry 17 }
|
|
|
|
prtFrTxFecn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of frames sent by this port during the
|
|
selected interval, indicating forward congestion."
|
|
::= { prtFrStatisEntry 18 }
|
|
|
|
prtFrRxBecn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of frames received by this port during the
|
|
selected interval, indicating backward congestion."
|
|
::= { prtFrStatisEntry 19 }
|
|
|
|
prtFrTxBecn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of frames sent by this port during the
|
|
selected interval, indicating backward congestion."
|
|
::= { prtFrStatisEntry 20 }
|
|
|
|
prtFrRxBeViol OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of data frames received by this port during the
|
|
selected interval, exceeding the Burst Excess value."
|
|
::= { prtFrStatisEntry 21 }
|
|
|
|
prtFrTxBeViol OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of data frames sent by this port during the
|
|
selected interval, exceeding the Burst Excess value."
|
|
::= { prtFrStatisEntry 22 }
|
|
|
|
prtFrRxBcViol OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of data frames received by this port during the
|
|
selected interval, exceeding the Burst Committed value."
|
|
::= { prtFrStatisEntry 23 }
|
|
|
|
prtFrTxBcViol OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of data frames sent by this port during the
|
|
selected interval, exceeding the Burst Committed value."
|
|
::= { prtFrStatisEntry 24 }
|
|
|
|
|
|
--prtCrStatis - Port Statistics for (CR) Cell Relay protocol
|
|
|
|
prtCrStatisTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtCrStatisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is applicable only for an active port running a
|
|
CR protocol ."
|
|
::= { prtCrStatis 1}
|
|
|
|
prtCrStatisEntry OBJECT-TYPE
|
|
SYNTAX PrtCrStatisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtCrStatisSltIdx, prtCrStatisPrtIdx, prtCrStatisInvIdx}
|
|
::= { prtCrStatisTable 1}
|
|
|
|
PrtCrStatisEntry ::=
|
|
SEQUENCE {
|
|
prtCrStatisSltIdx INTEGER,
|
|
prtCrStatisPrtIdx INTEGER,
|
|
prtCrStatisInvIdx INTEGER,
|
|
prtCrTimeElapsed Integer32,
|
|
prtCrRxTotalCells Counter32,
|
|
prtCrTxTotalCells Counter32,
|
|
prtCrRxDataCells Counter32,
|
|
prtCrTxDataCells Counter32
|
|
}
|
|
|
|
prtCrStatisSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the module is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
|
|
For stand-alone units this index will be notApplicable (255)."
|
|
::= { prtCrStatisEntry 1}
|
|
|
|
prtCrStatisPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number."
|
|
::= { prtCrStatisEntry 2}
|
|
|
|
prtCrStatisInvIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
currentInv (1),
|
|
last (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Interval of 15 min. for which the following statistics
|
|
counters are applicable."
|
|
::= { prtCrStatisEntry 3}
|
|
|
|
prtCrTimeElapsed OBJECT-TYPE
|
|
SYNTAX Integer32 (0..899)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of seconds that have elapsed since the
|
|
beginning of the current error-measurement interval.
|
|
This object is applicable mainly for the current interval.
|
|
For other interval:
|
|
- if data is available: value will be 899.
|
|
- if data is not available: value will be 0."
|
|
::= { prtCrStatisEntry 4 }
|
|
|
|
prtCrRxTotalCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of cells received by this port during the
|
|
selected interval."
|
|
::= { prtCrStatisEntry 5 }
|
|
|
|
prtCrTxTotalCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of cells sent by this port during the
|
|
selected interval."
|
|
::= { prtCrStatisEntry 6 }
|
|
|
|
prtCrRxDataCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Data Cells received by this port during the
|
|
selected interval."
|
|
::= { prtCrStatisEntry 7 }
|
|
|
|
prtCrTxDataCells OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Data Cells sent by this port during the
|
|
selected interval."
|
|
::= { prtCrStatisEntry 8 }
|
|
|
|
|
|
--prtDlciStatis - Port DLCI Statistics for FR, FR+ and CR protocol
|
|
|
|
prtDlciStatisTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtDlciStatisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is applicable only for an active port running an
|
|
FR, FR+ or CR protocol, with valid DLCIs ."
|
|
::= { prtDlciStatis 1}
|
|
|
|
prtDlciStatisEntry OBJECT-TYPE
|
|
SYNTAX PrtDlciStatisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtDlciSltIdx, prtDlciPrtIdx, prtDlciIdx}
|
|
::= { prtDlciStatisTable 1}
|
|
|
|
PrtDlciStatisEntry ::=
|
|
SEQUENCE {
|
|
prtDlciSltIdx INTEGER,
|
|
prtDlciPrtIdx INTEGER,
|
|
prtDlciIdx Integer32,
|
|
prtDlciRxDeFrames Counter32,
|
|
prtDlciTxDeFrames Counter32,
|
|
prtDlciRxDcrdCongDeFr Counter32,
|
|
prtDlciTxDcrdCongDeFr Counter32,
|
|
prtDlciRxDcrdCongAllFr Counter32,
|
|
prtDlciTxDcrdCongAllFr Counter32,
|
|
prtDlciTxFecn Counter32,
|
|
prtDlciTxBecn Counter32,
|
|
prtDlciRxBeViol Counter32,
|
|
prtDlciTxBeViol Counter32,
|
|
prtDlciRxBcViol Counter32,
|
|
prtDlciTxBcViol Counter32
|
|
}
|
|
|
|
prtDlciSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the module is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
|
|
For stand-alone units this index will be notApplicable (255)."
|
|
::= { prtDlciStatisEntry 1}
|
|
|
|
prtDlciPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number."
|
|
::= { prtDlciStatisEntry 2}
|
|
|
|
prtDlciIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..991)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique DLCI index for each valid
|
|
DLCI (16..991). "
|
|
::= { prtDlciStatisEntry 3}
|
|
|
|
prtDlciRxDeFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of De frames received by this DLCI."
|
|
::= { prtDlciStatisEntry 4 }
|
|
|
|
prtDlciTxDeFrames OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of De frames sent by this DLCI."
|
|
::= { prtDlciStatisEntry 5 }
|
|
|
|
prtDlciRxDcrdCongDeFr OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of De frames discarded due to congestion,
|
|
received by this DLCI."
|
|
::= { prtDlciStatisEntry 6 }
|
|
|
|
prtDlciTxDcrdCongDeFr OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of De frames discarded due to congestion,
|
|
sent by this DLCI."
|
|
::= { prtDlciStatisEntry 7 }
|
|
|
|
prtDlciRxDcrdCongAllFr OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All the frames discarded due to congestion,
|
|
received by this DLCI."
|
|
::= { prtDlciStatisEntry 8 }
|
|
|
|
prtDlciTxDcrdCongAllFr OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All the frames discarded due to congestion,
|
|
sent by this DLCI."
|
|
::= { prtDlciStatisEntry 9 }
|
|
|
|
prtDlciTxFecn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of frames sent by this DLCI, indicating forward
|
|
congestion."
|
|
::= { prtDlciStatisEntry 10 }
|
|
|
|
prtDlciTxBecn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of frames sent by this DLCI, indicating backward
|
|
congestion."
|
|
::= { prtDlciStatisEntry 11 }
|
|
|
|
prtDlciRxBeViol OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of data frames received by this DLCI, exceeding the
|
|
Burst Excess value."
|
|
::= { prtDlciStatisEntry 12 }
|
|
|
|
prtDlciTxBeViol OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of data frames sent by this DLCI, exceeding the Burst
|
|
Excess value."
|
|
::= { prtDlciStatisEntry 13 }
|
|
|
|
prtDlciRxBcViol OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of data frames received by this DLCI, exceeding the
|
|
Burst Committed value."
|
|
::= { prtDlciStatisEntry 14 }
|
|
|
|
prtDlciTxBcViol OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of data frames sent by this DLCI, exceeding the Burst
|
|
Committed value."
|
|
::= { prtDlciStatisEntry 15 }
|
|
|
|
|
|
--prtT1 Last FDL Message Table - Statistics
|
|
|
|
prtT1FdlMsgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtT1FdlMsgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is applicable for a T1 interface with 'esf'
|
|
LineType ."
|
|
::= { prtT1Statis 1}
|
|
|
|
prtT1FdlMsgEntry OBJECT-TYPE
|
|
SYNTAX PrtT1FdlMsgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtT1FdlMsgSltIdx, prtT1FdlMsgPrtIdx, prtT1FdlMsgFdlTxRx}
|
|
::= { prtT1FdlMsgTable 1}
|
|
|
|
PrtT1FdlMsgEntry ::=
|
|
SEQUENCE {
|
|
prtT1FdlMsgSltIdx INTEGER,
|
|
prtT1FdlMsgPrtIdx INTEGER,
|
|
prtT1FdlMsgFdlTxRx INTEGER,
|
|
prtT1FdlMsg OCTET STRING
|
|
}
|
|
|
|
prtT1FdlMsgSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the module is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= { prtT1FdlMsgEntry 1}
|
|
|
|
prtT1FdlMsgPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
MTML-1/T1 modules have just one external interface."
|
|
::= { prtT1FdlMsgEntry 2}
|
|
|
|
prtT1FdlMsgFdlTxRx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
tx (1),
|
|
rx (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Fdl tx/rx reference of the Fdl message."
|
|
::= { prtT1FdlMsgEntry 3}
|
|
|
|
|
|
prtT1FdlMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FDL message."
|
|
::= { prtT1FdlMsgEntry 4}
|
|
|
|
--
|
|
-- Extension of the Time Slot Config Table of ML ports
|
|
--
|
|
-- Time Slot is split to 8 Bits
|
|
|
|
|
|
prtExTsSplitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExTsSplitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry, except prtExTsBitTest that will be
|
|
written directly to the Active Configuration."
|
|
::= {cnfgPrtGen 1}
|
|
|
|
prtExTsSplitEntry OBJECT-TYPE
|
|
SYNTAX PrtExTsSplitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExTsCnfgIdx, prtExTsSltIdx, prtExTsPrtIdx,
|
|
prtExTsIdx, prtExTsBit}
|
|
::= { prtExTsSplitTable 1}
|
|
|
|
PrtExTsSplitEntry ::=
|
|
SEQUENCE {
|
|
prtExTsCnfgIdx Integer32,
|
|
prtExTsSltIdx INTEGER,
|
|
prtExTsPrtIdx Integer32,
|
|
prtExTsIdx Integer32,
|
|
prtExTsBit Integer32,
|
|
prtExTsIConSlot INTEGER,
|
|
prtExTsIConPrt Integer32,
|
|
prtExTsBitTest INTEGER,
|
|
prtExTsTxSignaling OCTET STRING,
|
|
prtExTsRxSignaling OCTET STRING,
|
|
prtExTsTxIoSignaling OCTET STRING,
|
|
prtExTsRxIoSignaling OCTET STRING
|
|
}
|
|
|
|
prtExTsCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtExTsSplitEntry 1}
|
|
|
|
prtExTsSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
|
|
notApplicable - for stand-alone units."
|
|
::= { prtExTsSplitEntry 2}
|
|
|
|
prtExTsPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
-- For MP:
|
|
-- {
|
|
-- exPrt1 (1),
|
|
-- inPrt1 (101)
|
|
-- }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
Most ML cards have only one external interface.
|
|
inPrt1 - for MTML-H/E1 cards.
|
|
For other products' index see their specification."
|
|
::= { prtExTsSplitEntry 3}
|
|
|
|
prtExTsIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique time slot position.
|
|
The valid time slots are:
|
|
1..24 for T1 Card and
|
|
1..31 for E1 interface.
|
|
In G732S-E1 lines, time slot 16 is not valid for data,
|
|
it is dedicated to multiframe synchronization bits
|
|
and voice signaling."
|
|
::= { prtExTsSplitEntry 4}
|
|
|
|
prtExTsBit OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Bit within the time slot.
|
|
The valid Bits are: 1..8.
|
|
255=NA."
|
|
::= { prtExTsSplitEntry 5}
|
|
|
|
prtExTsIConSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noConnect (2),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the specified time slot is
|
|
connected/routed internally in the Agent and to which card
|
|
it is connected.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
|
|
notApplicable - for stand-alone units."
|
|
::= {prtExTsSplitEntry 6}
|
|
|
|
prtExTsIConPrt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
-- For MP:
|
|
-- {
|
|
-- exPrt1 (1) ,
|
|
-- exPrt2 (2) ,
|
|
-- exPrt3 (3) ,
|
|
-- exPrt4 (4) ,
|
|
-- exPrt5 (5) ,
|
|
-- exPrt6 (6) ,
|
|
-- exPrt7 (7) ,
|
|
-- exPrt8 (8) ,
|
|
-- exPrt9 (9) ,
|
|
-- exPrt10 (10) ,
|
|
-- exPrt11 (11) ,
|
|
-- exPrt12 (12) ,
|
|
--
|
|
-- noConnect (100),
|
|
--
|
|
-- inPrt1 (101) ,
|
|
-- inPrt2 (102) ,
|
|
-- inPrt3 (103) ,
|
|
-- inPrt4 (104) ,
|
|
-- inPrt5 (105) ,
|
|
-- inPrt6 (106) ,
|
|
-- inPrt7 (107) ,
|
|
-- inPrt8 (108) ,
|
|
-- inPrt9 (109) ,
|
|
-- inPrt10 (110) ,
|
|
-- inPrt11 (111) ,
|
|
-- inPrt12 (112)
|
|
-- }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the internally (In Mux)
|
|
connected/routed port.
|
|
For other products' index see their specification."
|
|
::= {prtExTsSplitEntry 7}
|
|
|
|
prtExTsBitTest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
remoteBert (8),
|
|
localBert (30),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a test to be activated on the selected Bit.
|
|
It is applicable only when prtExPh1MlTsTest=split(254).
|
|
none - no test is applied for the selected Bit.
|
|
notApplicable - when prtExPh1MlTsTest is NOT split(254)."
|
|
::= { prtExTsSplitEntry 8}
|
|
|
|
prtExTsTxSignaling OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link - Tx Signaling per TS, for TSs having TS Type=Voice
|
|
(agnTsType=voice(2)).
|
|
It monitors what is sent to Link for the selected TS,
|
|
for A,B,C,D Signaling Bits.
|
|
Bit 1= LSB
|
|
Bit 8= MSB
|
|
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
|
|
::= { prtExTsSplitEntry 9}
|
|
|
|
prtExTsRxSignaling OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link - Rx Signaling per TS, for TSs having TS Type=Voice
|
|
(agnTsType=voice(2)).
|
|
It monitors what is received from Link for the selected TS,
|
|
for A,B,C,D Signaling Bits.
|
|
Bit 1= LSB
|
|
Bit 8= MSB
|
|
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
|
|
::= { prtExTsSplitEntry 10}
|
|
|
|
prtExTsTxIoSignaling OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IO - Tx Signaling per TS, for TSs having TS Type=Voice
|
|
(agnTsType=voice(2)).
|
|
It monitors what is sent to IO port for the selected TS,
|
|
for A,B,C,D Signaling Bits.
|
|
Bit 1= LSB
|
|
Bit 8= MSB
|
|
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
|
|
::= { prtExTsSplitEntry 11}
|
|
|
|
prtExTsRxIoSignaling OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IO - Rx Signaling per TS, for TSs having TS Type=Voice
|
|
(agnTsType=voice(2)).
|
|
It monitors what is received from IO port for the selected TS,
|
|
for A,B,C,D Signaling Bits.
|
|
Bit 1= LSB
|
|
Bit 8= MSB
|
|
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
|
|
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
|
|
::= { prtExTsSplitEntry 12}
|
|
|
|
|
|
prtCnfgAgenda OBJECT IDENTIFIER ::= {cnfgPrtGen 2}
|
|
|
|
prtAgendaBehaviourTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtAgendaBehaviourEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtCnfgAgenda 1}
|
|
|
|
prtAgendaBehaviourEntry OBJECT-TYPE
|
|
SYNTAX PrtAgendaBehaviourEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtAgendaBehaviourCnfgIdx, prtAgendaBehaviourSltIdx,
|
|
prtAgendaBehaviourPrtIdx }
|
|
::= { prtAgendaBehaviourTable 1}
|
|
|
|
PrtAgendaBehaviourEntry ::=
|
|
SEQUENCE {
|
|
prtAgendaBehaviourCnfgIdx Integer32,
|
|
prtAgendaBehaviourSltIdx Integer32,
|
|
prtAgendaBehaviourPrtIdx Integer32,
|
|
prtAgendaBehaviourOnOff INTEGER
|
|
}
|
|
|
|
prtAgendaBehaviourCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtAgendaBehaviourEntry 1}
|
|
|
|
prtAgendaBehaviourSltIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter should be:
|
|
- slot number for MX3000
|
|
- 255 = N/A for MX300/30. "
|
|
::= { prtAgendaBehaviourEntry 2 }
|
|
|
|
prtAgendaBehaviourPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter should be:
|
|
- port number for MX300/30
|
|
- 100 = N/A for MX3000. "
|
|
::= { prtAgendaBehaviourEntry 3 }
|
|
|
|
prtAgendaBehaviourOnOff OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this command to on(3) enables the agenda function
|
|
at module (3000) or port (300/30) level."
|
|
DEFVAL { off }
|
|
::= { prtAgendaBehaviourEntry 4 }
|
|
|
|
prtCnfgAgendaTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtCnfgAgendaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table allows the user to schedule the time a session
|
|
is active per week basis."
|
|
::= { prtCnfgAgenda 2}
|
|
|
|
prtCnfgAgendaEntry OBJECT-TYPE
|
|
SYNTAX PrtCnfgAgendaEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtCnfgAgendaCnfgIdx, prtCnfgAgendaSltIdx,
|
|
prtCnfgAgendaPrtIdx, prtCnfgAgendaDayIdx, prtCnfgAgendaSesId }
|
|
::= { prtCnfgAgendaTable 1}
|
|
|
|
PrtCnfgAgendaEntry ::=
|
|
SEQUENCE {
|
|
prtCnfgAgendaCnfgIdx Integer32,
|
|
prtCnfgAgendaSltIdx Integer32,
|
|
prtCnfgAgendaPrtIdx Integer32,
|
|
prtCnfgAgendaDayIdx INTEGER,
|
|
prtCnfgAgendaSesId Integer32,
|
|
prtCnfgAgendaFrom Integer32,
|
|
prtCnfgAgendaTo Integer32
|
|
}
|
|
|
|
prtCnfgAgendaCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtCnfgAgendaEntry 1}
|
|
|
|
prtCnfgAgendaSltIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is equal to:
|
|
-slot number for MX3000
|
|
-255 = N/A for MX300/30"
|
|
::= { prtCnfgAgendaEntry 2}
|
|
|
|
prtCnfgAgendaPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is equal to:
|
|
- port number for MX300/30
|
|
- port number for MX3000. For example 1-4 in MHS-4 cards.
|
|
- 100 = N/A for MX3000 when not used."
|
|
::= { prtCnfgAgendaEntry 3}
|
|
|
|
|
|
prtCnfgAgendaDayIdx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
monday (1),
|
|
tuesday (2),
|
|
wednesday(3),
|
|
thursday (4),
|
|
friday (5),
|
|
saturday (6),
|
|
sunday (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute for which day of the week this row applies."
|
|
::= { prtCnfgAgendaEntry 4 }
|
|
|
|
|
|
prtCnfgAgendaSesId OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user may define 4 different active intervals per day."
|
|
::= { prtCnfgAgendaEntry 5 }
|
|
|
|
prtCnfgAgendaFrom OBJECT-TYPE
|
|
SYNTAX Integer32 (0..86400)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start from time interval in seconds."
|
|
DEFVAL {86400}
|
|
::= { prtCnfgAgendaEntry 6 }
|
|
|
|
prtCnfgAgendaTo OBJECT-TYPE
|
|
SYNTAX Integer32 (0..86400)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"To time interval in seconds."
|
|
DEFVAL {86400}
|
|
::= { prtCnfgAgendaEntry 7 }
|
|
|
|
-- General Port Configuration parameters
|
|
|
|
prtGenCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtGenCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table allows the user to configure general
|
|
port parameters."
|
|
::= {cnfgPrtGen 3}
|
|
|
|
prtGenCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtGenCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtGenCnfgIdx, prtGenCnfgSltIdx, prtGenCnfgPrtIdx }
|
|
::= { prtGenCnfgTable 1}
|
|
|
|
PrtGenCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtGenCnfgIdx Integer32,
|
|
prtGenCnfgSltIdx INTEGER,
|
|
prtGenCnfgPrtIdx Integer32,
|
|
prtGenCnfgLinkToSlot INTEGER,
|
|
prtGenCnfgLinkToPort Integer32,
|
|
prtGenCnfgPortId Integer32,
|
|
prtGenCnfgBusConnection INTEGER,
|
|
prtGenCnfgInbandMng INTEGER,
|
|
prtGenCnfgInbandMngRoutProt INTEGER,
|
|
prtGenCnfgProtectionMode INTEGER, --not used
|
|
prtGenCnfgConnect INTEGER,
|
|
prtGenCnfgSignalingType INTEGER
|
|
}
|
|
|
|
prtGenCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg.
|
|
The write operation is valid only to the TmpCnfg."
|
|
::= { prtGenCnfgEntry 1}
|
|
|
|
prtGenCnfgSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted."
|
|
::= { prtGenCnfgEntry 2}
|
|
|
|
prtGenCnfgPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique external or internal port number.
|
|
For MP:
|
|
exPrt1 (1) .. exPrt16 (16) ,
|
|
notApplicable(100),
|
|
inPrt1 (101) .. inPrt84 (184) "
|
|
::= { prtGenCnfgEntry 3}
|
|
|
|
prtGenCnfgLinkToSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the slot of the ML card to which
|
|
the IO port is mapped."
|
|
::= { prtGenCnfgEntry 4}
|
|
|
|
prtGenCnfgLinkToPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the port in the prtGenCnfgLinkToSlot of
|
|
the ML card to which the IO port is mapped.
|
|
For MP:
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
inPrt1 (101) ,
|
|
inPrt2 (102) ,
|
|
inPrt3 (103) ,
|
|
inPrt4 (104) ,
|
|
inPrt5 (105) ,
|
|
inPrt6 (106) ,
|
|
inPrt7 (107) ,
|
|
inPrt8 (108) ,
|
|
inPrt9 (109),
|
|
inPrt10 (110),
|
|
inPrt11 (111),
|
|
inPrt12 (112),
|
|
inPrt13 (113),
|
|
inPrt14 (114),
|
|
inPrt15 (115),
|
|
inPrt16 (116),
|
|
inPrt17 (117),
|
|
inPrt18 (118),
|
|
inPrt19 (119),
|
|
inPrt20 (120),
|
|
inPrt21 (121),
|
|
inPrt22 (122),
|
|
inPrt23 (123),
|
|
inPrt24 (124),
|
|
inPrt25 (125),
|
|
inPrt26 (126),
|
|
inPrt27 (127),
|
|
inPrt28 (128),
|
|
inPrt29 (129),
|
|
inPrt30 (130),
|
|
inPrt31 (131),
|
|
inPrt32 (132),
|
|
inPrt33 (133),
|
|
inPrt34 (134),
|
|
inPrt35 (135),
|
|
inPrt36 (136),
|
|
inPrt37 (137),
|
|
inPrt38 (138),
|
|
inPrt39 (139),
|
|
inPrt40 (140),
|
|
inPrt41 (141),
|
|
inPrt42 (142),
|
|
inPrt43 (143),
|
|
inPrt44 (144),
|
|
inPrt45 (145),
|
|
inPrt46 (146),
|
|
inPrt47 (147),
|
|
inPrt48 (148),
|
|
inPrt49 (149),
|
|
inPrt50 (150),
|
|
inPrt51 (151),
|
|
inPrt52 (152),
|
|
inPrt53 (153),
|
|
inPrt54 (154),
|
|
inPrt55 (155),
|
|
inPrt56 (156),
|
|
inPrt57 (157),
|
|
inPrt58 (158),
|
|
inPrt59 (159),
|
|
inPrt60 (160),
|
|
inPrt61 (161),
|
|
inPrt62 (162),
|
|
inPrt63 (163),
|
|
inPrt64 (164),
|
|
inPrt65 (165),
|
|
inPrt66 (166),
|
|
inPrt67 (167),
|
|
inPrt68 (168),
|
|
inPrt69 (169),
|
|
inPrt70 (170),
|
|
inPrt71 (171),
|
|
inPrt72 (172),
|
|
inPrt73 (173),
|
|
inPrt74 (174),
|
|
inPrt75 (175),
|
|
inPrt76 (176),
|
|
inPrt77 (177),
|
|
inPrt78 (178),
|
|
inPrt79 (179),
|
|
inPrt80 (180),
|
|
inPrt81 (181),
|
|
inPrt82 (182),
|
|
inPrt83 (183),
|
|
inPrt84 (184),
|
|
notApplicable (255) "
|
|
::= { prtGenCnfgEntry 5}
|
|
|
|
prtGenCnfgPortId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16777215)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IO Port Id for V5.1 use.
|
|
This object is applicable only for part of the PSTN and ISDN IO ports.
|
|
Generally, 0 is a valid value.
|
|
Nevertheless, for ports that do not support this object, the value
|
|
will be: notApplicable= 0"
|
|
::= { prtGenCnfgEntry 6}
|
|
|
|
prtGenCnfgBusConnection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
partial (2),
|
|
full (3),
|
|
partialCD (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the support of the card regarding Bus Connection.
|
|
Same value for all ports of the card.
|
|
partial = 2 Buses (AB)
|
|
full = 4 Buses (ABCD)
|
|
partial CD = 2 Buses CD
|
|
Actually the support depends on the card's HW. But, since CL has to assign
|
|
data on Buses even when the card is not installed, this object has to be
|
|
configured.
|
|
If the actual card installed will not match the value configured, an Alarm
|
|
will be issued."
|
|
::= { prtGenCnfgEntry 7}
|
|
|
|
prtGenCnfgInbandMng OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether Inband Management is used over the
|
|
link."
|
|
::= {prtGenCnfgEntry 8}
|
|
|
|
prtGenCnfgInbandMngRoutProt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
rip2 (2),
|
|
proprietaryRip (3),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Inband Mng Routing Protocol of
|
|
the port."
|
|
::= {prtGenCnfgEntry 9}
|
|
|
|
prtGenCnfgProtectionMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
secondary (2),
|
|
primary (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Protection Mode of the port.
|
|
notApplicable- when Bus Protection Point=No.
|
|
For VC-4/Omni card this object is supported RO."
|
|
::= {prtGenCnfgEntry 10}
|
|
|
|
prtGenCnfgConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the port should be considered in
|
|
any of the mux algorithms."
|
|
::= {prtGenCnfgEntry 11}
|
|
|
|
prtGenCnfgSignalingType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
legacy (3),
|
|
abcd (4),
|
|
none (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object selects the Type of Signaling used by the port."
|
|
::= {prtGenCnfgEntry 12}
|
|
|
|
|
|
--
|
|
-- Compressed information.
|
|
--
|
|
-- Specially for RadView management station
|
|
--
|
|
prtCmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { cmprPrtGen 1 }
|
|
|
|
prtCmprEntry OBJECT-TYPE
|
|
SYNTAX PrtCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtCmprTypIdx, prtCmprCnfgIdx,prtCmprVersion,prtCmprSltIdx,prtCmprPrtIdx}
|
|
::= {prtCmprTable 1}
|
|
|
|
PrtCmprEntry ::=
|
|
SEQUENCE {
|
|
prtCmprTypIdx Integer32,
|
|
prtCmprCnfgIdx Integer32,
|
|
prtCmprVersion Integer32,
|
|
prtCmprSltIdx INTEGER,
|
|
prtCmprPrtIdx Integer32,
|
|
prtCmprObj OCTET STRING,
|
|
prtCmprStatisticObj OCTET STRING
|
|
}
|
|
|
|
prtCmprTypIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Type of the Compressed being
|
|
referred."
|
|
::= { prtCmprEntry 1}
|
|
|
|
prtCmprCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the configuration to which the
|
|
Compressed information is related."
|
|
::= { prtCmprEntry 2}
|
|
|
|
prtCmprVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the version of the internal format of
|
|
the Compressed data"
|
|
::= { prtCmprEntry 3}
|
|
|
|
prtCmprSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
psA (1),
|
|
psB (2),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number of the slot position
|
|
where the card is inserted.
|
|
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
|
|
are not valid."
|
|
::= { prtCmprEntry 4}
|
|
|
|
prtCmprPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique identifier of the port
|
|
the compressed information relates to.
|
|
Valid values: exPrt1 (1) .. exPrt16 (16) ,
|
|
inPrt1 (101) .. inPrt48 (148)."
|
|
::= { prtCmprEntry 5}
|
|
|
|
prtCmprObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the compressed information itself."
|
|
::= { prtCmprEntry 6}
|
|
|
|
prtCmprStatisticObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the compressed statistics information itself."
|
|
::= { prtCmprEntry 7}
|
|
|
|
|
|
-- Compressed Dlci table in the Port level
|
|
-- The only way of reading this table is by the command 'GET NEXT'
|
|
|
|
prtDlciCmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtDlciCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { cmprPrtGen 2 }
|
|
|
|
prtDlciCmprEntry OBJECT-TYPE
|
|
SYNTAX PrtDlciCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtDlciCmprCnfgIdx,prtDlciCmprVersion,
|
|
prtDlciCmprSltIdx,prtDlciCmprPrtIdx,prtDlciCmprDlciIdx}
|
|
::= {prtDlciCmprTable 1}
|
|
|
|
PrtDlciCmprEntry ::=
|
|
SEQUENCE {
|
|
prtDlciCmprCnfgIdx Integer32,
|
|
prtDlciCmprVersion Integer32,
|
|
prtDlciCmprSltIdx INTEGER,
|
|
prtDlciCmprPrtIdx INTEGER,
|
|
prtDlciCmprDlciIdx Integer32,
|
|
prtDlciCmprObj OCTET STRING
|
|
}
|
|
|
|
prtDlciCmprCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the configuration to which the
|
|
Compressed information is related."
|
|
::= { prtDlciCmprEntry 1}
|
|
|
|
prtDlciCmprVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the version of the internal format of
|
|
the Compressed data"
|
|
::= { prtDlciCmprEntry 2}
|
|
|
|
prtDlciCmprSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number of the slot position
|
|
where the module is inserted.
|
|
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
|
|
are not valid."
|
|
::= { prtDlciCmprEntry 3}
|
|
|
|
prtDlciCmprPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
inPrt1 (101) ,
|
|
inPrt2 (102) ,
|
|
inPrt3 (103) ,
|
|
inPrt4 (104) ,
|
|
inPrt5 (105) ,
|
|
inPrt6 (106) ,
|
|
inPrt7 (107) ,
|
|
inPrt8 (108) ,
|
|
inPrt9 (109) ,
|
|
inPrt10 (110) ,
|
|
inPrt11 (111) ,
|
|
inPrt12 (112)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique identifier of the port
|
|
the compressed information relates to.
|
|
All the values are valid."
|
|
::= { prtDlciCmprEntry 4}
|
|
|
|
prtDlciCmprDlciIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique identifier of the Dlci
|
|
the compressed information relates to.
|
|
The values are between 16 - 991."
|
|
::= { prtDlciCmprEntry 5}
|
|
|
|
prtDlciCmprObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the compressed information itself."
|
|
::= { prtDlciCmprEntry 6}
|
|
|
|
|
|
-- Compressed Alarm table in the Port level
|
|
-- The only way of reading this table is by the command 'GET NEXT'
|
|
|
|
prtAlarmsCmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtAlarmsCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= {cmprPrtGen 3}
|
|
|
|
prtAlarmsCmprEntry OBJECT-TYPE
|
|
SYNTAX PrtAlarmsCmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtAlarmsCmprVersion,prtAlarmsCmprAlarmSlot,
|
|
prtAlarmsCmprAlarmPort,prtAlarmsCmprAlarmIdx}
|
|
::= {prtAlarmsCmprTable 1}
|
|
|
|
PrtAlarmsCmprEntry ::=
|
|
SEQUENCE {
|
|
prtAlarmsCmprVersion Integer32,
|
|
prtAlarmsCmprAlarmSlot Integer32,
|
|
prtAlarmsCmprAlarmPort Integer32,
|
|
prtAlarmsCmprAlarmIdx Integer32,
|
|
prtAlarmsCmprObj OCTET STRING
|
|
}
|
|
|
|
prtAlarmsCmprVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the version of the internal format of
|
|
the Compressed data"
|
|
::= { prtAlarmsCmprEntry 1}
|
|
|
|
prtAlarmsCmprAlarmSlot OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the desired slot position.
|
|
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
|
|
are not valid.
|
|
For Stand-alone units, notApplicable(255) will appear."
|
|
::= { prtAlarmsCmprEntry 2}
|
|
|
|
prtAlarmsCmprAlarmPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique identifier of the port
|
|
the alarm applies to.
|
|
All the values are valid. No alarms exist for a non-existing
|
|
port. IP Bundles are considered a port too, for this matter."
|
|
::= { prtAlarmsCmprEntry 3}
|
|
|
|
prtAlarmsCmprAlarmIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify an entry in the alarm status table
|
|
of the agent."
|
|
::= { prtAlarmsCmprEntry 4}
|
|
|
|
prtAlarmsCmprObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the compressed information itself."
|
|
::= { prtAlarmsCmprEntry 5}
|
|
|
|
|
|
--
|
|
-- Specific port status for each module Type
|
|
-- *****************************************
|
|
--
|
|
|
|
-- Megaplex?000/?004 port specific status for HS(TDM) modules
|
|
-- HS-2,HS-3,HS-Q, HS-6, HS-12
|
|
prtSExHsfStatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSExHsfStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= {statPrtMux 6}
|
|
|
|
prtSExHsfStatEntry OBJECT-TYPE
|
|
SYNTAX PrtSExHsfStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtSExHsfSltIdx, prtSExHsfPrtIdx }
|
|
::= {prtSExHsfStatTable 1}
|
|
|
|
PrtSExHsfStatEntry ::=
|
|
SEQUENCE {
|
|
prtSExHsfSltIdx INTEGER,
|
|
prtSExHsfPrtIdx INTEGER,
|
|
prtSExHsfInterfaceTyp INTEGER,
|
|
prtSExHsfRts INTEGER
|
|
}
|
|
|
|
|
|
prtSExHsfSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid."
|
|
::= { prtSExHsfStatEntry 1}
|
|
|
|
prtSExHsfPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
exPrt11 (11) ,
|
|
exPrt12 (12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number. "
|
|
::= { prtSExHsfStatEntry 2}
|
|
|
|
prtSExHsfInterfaceTyp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
v35 (2),
|
|
rs422 (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique interface type of a
|
|
selected port."
|
|
::= { prtSExHsfStatEntry 3}
|
|
|
|
prtSExHsfRts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
notActive (2),
|
|
active (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique RTS control signal state."
|
|
::= { prtSExHsfStatEntry 4}
|
|
|
|
|
|
|
|
-- ISDN Port Status
|
|
|
|
prtIsdnStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtIsdnStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains ISDN Statistics parameters that do not appear
|
|
in the standard MIBs or for agents that don't support the standard Index
|
|
of Call Set Up Time."
|
|
::= { statPrtMux 16 }
|
|
|
|
prtIsdnStatusEntry OBJECT-TYPE
|
|
SYNTAX PrtIsdnStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries for ISDN Statistics parameters that do not appear in the standard MIBs
|
|
or for agents that don't support the standard Index of Call Set Up Time."
|
|
INDEX { ifIndex }
|
|
::= { prtIsdnStatusTable 1 }
|
|
|
|
|
|
PrtIsdnStatusEntry ::=
|
|
SEQUENCE {
|
|
prtIsdnStatusDspMode INTEGER,
|
|
prtIsdnStatusCallState INTEGER,
|
|
prtIsdnStatusCallingNumber DisplayString,
|
|
prtIsdnStatusCalledNumber DisplayString,
|
|
prtIsdnStatusCalledIP IpAddress,
|
|
prtIsdnStatusCallDirection INTEGER
|
|
}
|
|
|
|
prtIsdnStatusDspMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
voice (2),
|
|
idle (3),
|
|
fax (4),
|
|
vbd (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DSP can be in one of the following Modes:
|
|
Voice, Idle, Fax, Voice Band Data (VBD)- Modem."
|
|
::= { prtIsdnStatusEntry 1 }
|
|
|
|
prtIsdnStatusCallState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
present (2),
|
|
overlapReceive (3),
|
|
incoming (4),
|
|
receive (5),
|
|
initiated (6),
|
|
overlapSend (7),
|
|
outGoingProceed (8),
|
|
callDeliver (9),
|
|
active (10),
|
|
disconnectIndicate (11),
|
|
releaseRequest (12),
|
|
disconnectReq (13),
|
|
notActive (14)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state that the current call is in."
|
|
::= { prtIsdnStatusEntry 2 }
|
|
|
|
prtIsdnStatusCallingNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the local Number (ISDN Address) associated with this entry."
|
|
::= { prtIsdnStatusEntry 3 }
|
|
|
|
prtIsdnStatusCalledNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the remote Number (ISDN Address) associated with this entry."
|
|
::= { prtIsdnStatusEntry 4 }
|
|
|
|
prtIsdnStatusCalledIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the remote IP Address associated with this entry."
|
|
::= { prtIsdnStatusEntry 5 }
|
|
|
|
prtIsdnStatusCallDirection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
incoming (2),
|
|
outgoing (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Attribute indicating the Direction of the Call.
|
|
The value of notApplicable will be used for example when
|
|
prtIsdnStatusCallState = notActive(14)."
|
|
::= { prtIsdnStatusEntry 6 }
|
|
|
|
|
|
cnfgMdlMux OBJECT IDENTIFIER ::= {mdlMux 1}
|
|
mdlPbxFramerCnfg OBJECT IDENTIFIER ::= {cnfgMdlMux 1}
|
|
|
|
mdlPbxFramerCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlPbxFramerCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains parameters relevant to a module belonging to
|
|
a digital voice system, except mdlPbxFraEnhEcho which is relevant
|
|
also for analog cards."
|
|
::= {mdlPbxFramerCnfg 1}
|
|
|
|
mdlPbxFramerCnfgEntry OBJECT-TYPE
|
|
SYNTAX MdlPbxFramerCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { mdlPbxFraCnfgIdx, mdlPbxFraSltIdx }
|
|
::= {mdlPbxFramerCnfgTable 1}
|
|
|
|
MdlPbxFramerCnfgEntry ::=
|
|
SEQUENCE {
|
|
mdlPbxFraCnfgIdx Integer32,
|
|
mdlPbxFraSltIdx INTEGER,
|
|
mdlPbxFraEnhEcho INTEGER,
|
|
mdlPbxFraTSGroupAss INTEGER,
|
|
mdlPbxFraSignalMode INTEGER,
|
|
mdlPbxFraSignalVector OCTET STRING,
|
|
mdlPbxFraSignalMask OCTET STRING,
|
|
mdlPbxFraFramerSlot INTEGER,
|
|
mdlPbxFraSignaling INTEGER,
|
|
mdlPbxFraTransSigTs Integer32
|
|
}
|
|
|
|
mdlPbxFraCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
-- DEFVAL {1}
|
|
::= { mdlPbxFramerCnfgEntry 1}
|
|
|
|
mdlPbxFraSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER{ io1(5), io2(6), io3(7), io4(8), io5(9),
|
|
io6(10), io7(11), io8(12), io9(13), io10(14),
|
|
io11(15), io12(16) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot relevant to this module."
|
|
::= { mdlPbxFramerCnfgEntry 2}
|
|
|
|
mdlPbxFraEnhEcho OBJECT-TYPE
|
|
SYNTAX INTEGER { notApplicable(1) ,
|
|
disabled(2),
|
|
ms16(3),
|
|
ms32(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Refers to external ports of an analogue module
|
|
and to the internal ports of the other mvc4 types
|
|
of modules.
|
|
ms16(3) means that the four voice ports have enhanced
|
|
echo of 16ms.
|
|
ms32(4) means that the two first ports have enhanced
|
|
echo of 32 ms while the last two ports have no
|
|
enhanced echo."
|
|
::= { mdlPbxFramerCnfgEntry 3}
|
|
|
|
mdlPbxFraTSGroupAss OBJECT-TYPE
|
|
SYNTAX INTEGER{ group1(1), group2(2), group3(3), group4(4),
|
|
group5(5), group6(6), group7(7), group8(8),
|
|
notApplicable(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In case of T1 modules:
|
|
group1=(1,2,3,4), ...., group6=(21,22,23,24)
|
|
while in case of E1 modules:
|
|
- If prtExPh1MlLineType=g732sE1 or g732sE1CRC:
|
|
group1=(1,2,3,4),..,group4=(13,14,15,17),
|
|
group5=(18,19,20,21),...,group7=(26,27,28,29)
|
|
group8=(30,31).
|
|
- If prtExPh1MlLineType=g732nE1 or g732nE1CRC:
|
|
group1=(1,2,3,4),..,group4=(13,14,15,16),
|
|
group5=(17,18,19,20),...,group7=(25,26,27,28)
|
|
group8=(29,30,31)."
|
|
::= { mdlPbxFramerCnfgEntry 4}
|
|
|
|
mdlPbxFraSignalMode OBJECT-TYPE
|
|
SYNTAX INTEGER { notApplicable(1),
|
|
tieTrunk(2),
|
|
tieInvert(3),
|
|
casTrans(4),
|
|
userDefined(5),
|
|
ccsTrans(6),
|
|
noSignaling(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Refers to the signaling mode of the Framer module.
|
|
tieTrunk(2), tieInvert(3), casTrans(4) are standard
|
|
coding of the signaling protocol.
|
|
|
|
casTrans(4) is Channel Associated Signaling (the signaling is within the
|
|
channels time slot).
|
|
ccsTrans(6) is Transparent Common Channel Signaling (the signaling is not within
|
|
the channels time slot - a TS for signaling is used).
|
|
|
|
userDefined(5) allows the user to define the signaling
|
|
protocol he wants. In this case, the next two MIB fields
|
|
are relevant."
|
|
DEFVAL { casTrans }
|
|
::= { mdlPbxFramerCnfgEntry 5}
|
|
|
|
mdlPbxFraSignalVector OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In the case of mdlPbxFraSignalMode = userDefined(5), this
|
|
field defines the A,B,C Bits. D bit is supplied for future
|
|
versions.
|
|
Bit 1 = Bit A ON Hook - Local
|
|
Bit 2 = Bit B ON Hook - Local
|
|
Bit 3 = Bit C ON Hook - Local
|
|
Bit 4 = Bit D ON Hook - Local
|
|
Bit 5 = Bit A OFF Hook - Local
|
|
Bit 6 = Bit B OFF Hook - Local
|
|
Bit 7 = Bit C OFF Hook - Local
|
|
Bit 8 = Bit D OFF Hook - Local
|
|
|
|
Bit 9 = Bit A ON Hook - Remote
|
|
Bit 10 = Bit B ON Hook - Remote
|
|
Bit 11 = Bit C ON Hook - Remote
|
|
Bit 12 = Bit D ON Hook - Remote
|
|
Bit 13 = Bit A OFF Hook - Remote
|
|
Bit 14 = Bit B OFF Hook - Remote
|
|
Bit 15 = Bit C OFF Hook - Remote
|
|
Bit 16 = Bit D OFF Hook - Remote
|
|
|
|
In conjunction with the Mask, mdlPbxFraSignalMask, it is
|
|
possible to compute the signal mode."
|
|
DEFVAL { '0000'H}
|
|
::= { mdlPbxFramerCnfgEntry 6}
|
|
|
|
mdlPbxFraSignalMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In the case of mdlPbxFraSignalMode = userDefined(5), this
|
|
field defines the 'don't care' A,B,C Bits. D bit is supplied
|
|
for future versions.
|
|
Bit 1 = Bit A ON Hook - Local
|
|
Bit 2 = Bit B ON Hook - Local
|
|
Bit 3 = Bit C ON Hook - Local
|
|
Bit 4 = Bit D ON Hook - Local
|
|
Bit 5 = Bit A OFF Hook - Local
|
|
Bit 6 = Bit B OFF Hook - Local
|
|
Bit 7 = Bit C OFF Hook - Local
|
|
Bit 8 = Bit D OFF Hook - Local
|
|
|
|
Bit 9 = Bit A ON Hook - Remote
|
|
Bit 10 = Bit B ON Hook - Remote
|
|
Bit 11 = Bit C ON Hook - Remote
|
|
Bit 12 = Bit D ON Hook - Remote
|
|
Bit 13 = Bit A OFF Hook - Remote
|
|
Bit 14 = Bit B OFF Hook - Remote
|
|
Bit 15 = Bit C OFF Hook - Remote
|
|
Bit 16 = Bit D OFF Hook - Remote."
|
|
DEFVAL { 'ffff'H }
|
|
::= { mdlPbxFramerCnfgEntry 7}
|
|
|
|
mdlPbxFraFramerSlot OBJECT-TYPE
|
|
SYNTAX INTEGER { io1(5), io2(6), io3(7), io4(8), io5(9),
|
|
io6(10), io7(11), io8(12), io9(13), io10(14),
|
|
io11(15), io12(16) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot where is sitting the Framer."
|
|
::= { mdlPbxFramerCnfgEntry 8}
|
|
|
|
mdlPbxFraSignaling OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
endToEnd (2),
|
|
localTermination(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signaling - describes the way the signaling ABCD bits pass from the
|
|
local extension to the remote extension and vice-versa.
|
|
|
|
endToEnd = the signaling ABCD bits pass without change from local to
|
|
remote extension.
|
|
localTermination = the signaling ABCD bits received from the local extension
|
|
are translated to different ON Hook/OFF Hook bit values and then
|
|
passed to remote extension. This is relevant when the Local
|
|
and Remote ON Hook/OFF Hook values are different."
|
|
DEFVAL { endToEnd }
|
|
::= { mdlPbxFramerCnfgEntry 9}
|
|
|
|
mdlPbxFraTransSigTs OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the Time Slot that is used for Transparent CCS signaling.
|
|
The values of this TS are 1-24 for T1 & 1-31 for E1.
|
|
The default for E1 is 16 & for T1 it is 24. If no signaling is used then
|
|
the TS should be 255 (None)."
|
|
::= { mdlPbxFramerCnfgEntry 10}
|
|
|
|
--Protected IP Adresses list for ML-IP cards of MP-2100/4 and MP-2200
|
|
--for IP Ring Mode
|
|
|
|
mdlProtIpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlProtIpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains Protected IP Addresses for ML-IP cards
|
|
when working in IP Ring Mode."
|
|
::= {cnfgMdlMux 2}
|
|
|
|
mdlProtIpEntry OBJECT-TYPE
|
|
SYNTAX MdlProtIpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { mdlProtIpCnfgIdx, mdlProtIpSlotIdx, mdlProtIpAddress}
|
|
::= {mdlProtIpTable 1}
|
|
|
|
MdlProtIpEntry ::=
|
|
SEQUENCE {
|
|
mdlProtIpCnfgIdx Integer32,
|
|
mdlProtIpSlotIdx INTEGER,
|
|
mdlProtIpAddress IpAddress,
|
|
mdlProtIpRowStatus RowStatus
|
|
}
|
|
|
|
mdlProtIpCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg being accessed.
|
|
Idx 255 relates to the TmpCnfg.
|
|
For Agents having several configuration, Write operation is
|
|
allowed only to the Temporary Configuration."
|
|
::= { mdlProtIpEntry 1}
|
|
|
|
mdlProtIpSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the module is inserted.
|
|
In the 2104 Unit the entries io6(10)..io16) are not valid."
|
|
::= { mdlProtIpEntry 2}
|
|
|
|
mdlProtIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Protected IP address."
|
|
::= { mdlProtIpEntry 3 }
|
|
|
|
mdlProtIpRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter allows creating/deleting entries of this table."
|
|
::= { mdlProtIpEntry 4 }
|
|
|
|
|
|
statMdlMux OBJECT IDENTIFIER ::= {mdlMux 2}
|
|
|
|
--
|
|
-- Card status table
|
|
--
|
|
mdlStatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { statMdlMux 1 }
|
|
|
|
mdlStatEntry OBJECT-TYPE
|
|
SYNTAX MdlStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { mdlStatSltIdx }
|
|
::= { mdlStatTable 1}
|
|
|
|
MdlStatEntry ::=
|
|
SEQUENCE {
|
|
mdlStatSltIdx INTEGER,
|
|
mdlStatHostIP IpAddress,
|
|
mdlStatHostMask IpAddress,
|
|
mdlStatDefaultGateway IpAddress
|
|
}
|
|
|
|
mdlStatSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
psA (1),
|
|
psB (2),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify a slot position in the mux.
|
|
In the 2104 Unit the entries psB(2),clB(4),io6(10)..io12(16)
|
|
are not valid."
|
|
::= { mdlStatEntry 1}
|
|
|
|
mdlStatHostIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The host interface IP address when DHCP Client=Yes.
|
|
This object is relevant only when DHCP Client=Yes "
|
|
::= { mdlStatEntry 2 }
|
|
|
|
mdlStatHostMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The host interface subnet mask when DHCP Client=Yes.
|
|
This object is relevant only when DHCP Client=Yes "
|
|
::= { mdlStatEntry 3 }
|
|
|
|
mdlStatDefaultGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Default Gateway's IP Address when DHCP Client=Yes.
|
|
This object is relevant only when DHCP Client=Yes "
|
|
::= { mdlStatEntry 4 }
|
|
|
|
|
|
--
|
|
-- Specific port config for each module Type
|
|
-- *****************************************
|
|
|
|
--
|
|
-- MPCL.1 configuration parameters
|
|
--
|
|
--prtExClCnfgTable OBJECT IDENTIFIER ::= {prtClCnfg 1}
|
|
-- prtInClInbandTable OBJECT IDENTIFIER ::= {prtClCnfg 2}
|
|
|
|
prtExClCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExClCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= {prtClCnfg 1}
|
|
|
|
prtExClCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExClCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All the entries at this table are identical (have the same
|
|
value) for all the configurations (1..100) except the
|
|
TmpCnfg.
|
|
The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
INDEX {prtExClCnfgIdx, prtExClSltIdx, prtExClPrtIdx }
|
|
::= { prtExClCnfgTable 1}
|
|
|
|
PrtExClCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExClCnfgIdx Integer32,
|
|
prtExClSltIdx INTEGER,
|
|
prtExClPrtIdx INTEGER,
|
|
prtExClUsage INTEGER,
|
|
prtExClRate INTEGER,
|
|
prtExClDataBits INTEGER,
|
|
prtExClParity INTEGER,
|
|
prtExClStopBits INTEGER,
|
|
prtExClRoutingProtocol INTEGER,
|
|
prtExClEnabled INTEGER
|
|
}
|
|
|
|
|
|
prtExClCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg."
|
|
::= { prtExClCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExClSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
clA (3),
|
|
clB (4),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted. Because the second Cl is only for
|
|
redundancy, all the parameters are identical in the two
|
|
modules, i.e. change of any parameter in one module will
|
|
change automatically the value of the other module..
|
|
In the ?004 Unit the entry clB(4) is not valid."
|
|
::= { prtExClCnfgEntry 2}
|
|
|
|
prtExClPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number. "
|
|
::= { prtExClCnfgEntry 3}
|
|
|
|
prtExClUsage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
noUse (2),
|
|
nmsSlip (3),
|
|
nmsPpp (4),
|
|
muxSlip (5),
|
|
muxPpp (6),
|
|
terminal(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates what is the usage of the port."
|
|
::= { prtExClCnfgEntry 4}
|
|
|
|
prtExClRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r300Bps (1),
|
|
r1200Bps (2),
|
|
r2400Bps (3),
|
|
r4800Bps (4),
|
|
r9600Bps (5),
|
|
r19200Bps (6),
|
|
r38400Bps (7),
|
|
r57600Bps (8),
|
|
r115200Bps (9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the operation rate of the port."
|
|
::= { prtExClCnfgEntry 5}
|
|
|
|
prtExClDataBits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dataBits7Bits (1),
|
|
dataBits8Bits (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the number of data bits in async
|
|
frame"
|
|
::= { prtExClCnfgEntry 6}
|
|
|
|
prtExClParity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
odd (1),
|
|
even (2),
|
|
none (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates if the parity operation mode in
|
|
async frame"
|
|
::= { prtExClCnfgEntry 7}
|
|
|
|
prtExClStopBits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
stopBits1Bit (1),
|
|
stopBits1dot5Bits (2),
|
|
stopBits2Bits (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the minimum number of stop bits in
|
|
the tx async frame"
|
|
::= { prtExClCnfgEntry 8}
|
|
|
|
prtExClRoutingProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
rip2 (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the routing protocol of the port.
|
|
When prtExClUsage is nmsSlip or nmsPpp - all values are
|
|
applicable .
|
|
Else - only 'none' is applicable."
|
|
::= { prtExClCnfgEntry 9}
|
|
|
|
prtExClEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates if Ethernet port of CL
|
|
is enabled or not for management.
|
|
It is applicable only on the ETH port of the CL, when the
|
|
MP includes an ML-IP card.
|
|
disabled - will happen when there is Inband Management via
|
|
the ML-IP link/s
|
|
enabled - will happen when ML-IP link/s is not used for Inband
|
|
Management, but CL's ETH port ."
|
|
::= { prtExClCnfgEntry 10}
|
|
|
|
--
|
|
-- MPH1.T1, MPH1.E1, MTML.1/T1 , MTML.1/E1, ML-20
|
|
-- TDM and Hybrid(TDM & Packet) Main Link Modules
|
|
--
|
|
--prtExPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 1}
|
|
--prtExPh1MlTsTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 2}
|
|
--prtInPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 3}
|
|
--prtInPh1MlDlciTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 4}
|
|
--prtPhMlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 5}
|
|
|
|
--
|
|
-- T1/E1 Port Objects
|
|
--
|
|
prtExPh1MlCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExPh1MlCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"- For products supporting more than one configuration, the write operation
|
|
into the Table is valid only to the TmpCnfg entry.
|
|
- For products that do not support configurations, the write operation
|
|
into the Table will be to prtExPh1MlCnfgIdx=1."
|
|
::= {prtPh1MlCnfg 1}
|
|
|
|
prtExPh1MlCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExPh1MlCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExPh1MlCnfgIdx, prtExPh1MlSltIdx, prtExPh1MlPrtIdx }
|
|
::= { prtExPh1MlCnfgTable 1}
|
|
|
|
PrtExPh1MlCnfgEntry ::= SEQUENCE {
|
|
prtExPh1MlCnfgIdx Integer32,
|
|
prtExPh1MlSltIdx INTEGER,
|
|
prtExPh1MlPrtIdx INTEGER,
|
|
prtExPh1MlConnect INTEGER,
|
|
prtExPh1MlLineType INTEGER,
|
|
prtExPh1MlLineCode INTEGER,
|
|
prtExPh1MlLineLen INTEGER,
|
|
prtExPh1MlRestoreTime INTEGER,
|
|
prtExPh1MlTxGain INTEGER,
|
|
prtExPh1MlRxSensitivity INTEGER,
|
|
prtExPh1MlIdleCode Integer32,
|
|
prtExPh1MlTdmTrunk INTEGER,
|
|
prtExPh1MlClkMode INTEGER,
|
|
prtExPh1MlMfClkSrcSlt INTEGER,
|
|
prtExPh1MlMfClkSrcPrt INTEGER,
|
|
prtExPh1MlFdlType INTEGER,
|
|
prtExPh1MlInbandMng INTEGER,
|
|
prtExPh1MlInbandMngRate INTEGER,
|
|
prtExPh1MlRedundType INTEGER,
|
|
prtExPh1MlRedundSlot INTEGER,
|
|
prtExPh1MlRedundPort INTEGER,
|
|
prtExPh1MlRedundRecTime Integer32,
|
|
prtExPh1MlInbandMngRoutProt INTEGER,
|
|
prtExPh1MlIfType INTEGER,
|
|
prtExPh1MlMultiplier INTEGER,
|
|
prtExPh1MlSupportedTS Integer32,
|
|
prtExPh1MlImpedance INTEGER,
|
|
prtExPh1MlQ50BwControl INTEGER,
|
|
prtExPh1MlQ50SignalPair INTEGER,
|
|
prtExPh1MlInternalSwitch INTEGER,
|
|
prtExPh1MlSigService INTEGER,
|
|
prtExPh1MlFragmentSize Integer32
|
|
}
|
|
|
|
prtExPh1MlCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtExPh1MlCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExPh1MlSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the module is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid.
|
|
For the Vmux2100 Main Board notApplicable (1) is used."
|
|
::= { prtExPh1MlCnfgEntry 2}
|
|
|
|
prtExPh1MlPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
exPrt3 (3),
|
|
exPrt4 (4),
|
|
exPrt5 (5),
|
|
exPrt6 (6),
|
|
exPrt7 (7),
|
|
exPrt8 (8),
|
|
exPrt9 (9),
|
|
exPrt10 (10),
|
|
exPrt11 (11),
|
|
exPrt12 (12),
|
|
exPrt13 (13),
|
|
exPrt14 (14),
|
|
exPrt15 (15),
|
|
exPrt16 (16),
|
|
exPrt17 (17),
|
|
exPrt18 (18),
|
|
inPrt1 (101),
|
|
inPrt2 (102),
|
|
inPrt3 (103),
|
|
inPrt4 (104),
|
|
inPrt5 (105),
|
|
inPrt6 (106),
|
|
inPrt7 (107),
|
|
inPrt8 (108),
|
|
inPrt9 (109),
|
|
inPrt10 (110),
|
|
inPrt11 (111),
|
|
inPrt12 (112),
|
|
inPrt13 (113),
|
|
inPrt14 (114),
|
|
inPrt15 (115),
|
|
inPrt16 (116),
|
|
inPrt17 (117),
|
|
inPrt18 (118),
|
|
inPrt19 (119),
|
|
inPrt20 (120),
|
|
inPrt21 (121),
|
|
inPrt22 (122),
|
|
inPrt23 (123),
|
|
inPrt24 (124),
|
|
inPrt25 (125),
|
|
inPrt26 (126),
|
|
inPrt27 (127),
|
|
inPrt28 (128),
|
|
inPrt29 (129),
|
|
inPrt30 (130),
|
|
inPrt31 (131),
|
|
inPrt32 (132),
|
|
inPrt33 (133),
|
|
inPrt34 (134),
|
|
inPrt35 (135),
|
|
inPrt36 (136),
|
|
inPrt37 (137),
|
|
inPrt38 (138),
|
|
inPrt39 (139),
|
|
inPrt40 (140),
|
|
inPrt41 (141),
|
|
inPrt42 (142),
|
|
inPrt43 (143),
|
|
inPrt44 (144),
|
|
inPrt45 (145),
|
|
inPrt46 (146),
|
|
inPrt47 (147),
|
|
inPrt48 (148),
|
|
inPrt49 (149),
|
|
inPrt50 (150),
|
|
inPrt51 (151),
|
|
inPrt52 (152),
|
|
inPrt53 (153),
|
|
inPrt54 (154),
|
|
inPrt55 (155),
|
|
inPrt56 (156),
|
|
inPrt57 (157),
|
|
inPrt58 (158),
|
|
inPrt59 (159),
|
|
inPrt60 (160),
|
|
inPrt61 (161),
|
|
inPrt62 (162),
|
|
inPrt63 (163),
|
|
inPrt64 (164),
|
|
inPrt65 (165),
|
|
inPrt66 (166),
|
|
inPrt67 (167),
|
|
inPrt68 (168),
|
|
inPrt69 (169),
|
|
inPrt70 (170),
|
|
inPrt71 (171),
|
|
inPrt72 (172),
|
|
inPrt73 (173),
|
|
inPrt74 (174),
|
|
inPrt75 (175),
|
|
inPrt76 (176),
|
|
inPrt77 (177),
|
|
inPrt78 (178),
|
|
inPrt79 (179),
|
|
inPrt80 (180),
|
|
inPrt81 (181),
|
|
inPrt82 (182),
|
|
inPrt83 (183),
|
|
inPrt84 (184)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
MP-2100/2200:
|
|
MTML-1/E1 and MTML-1/T1 cards have only one external interface.
|
|
inPrt1, inPrt2 - for MTML-H/2E1 and HSH cards.
|
|
inPrt1..inPrt4 - for MTML-E2 and MSL-4 cards.
|
|
exPrt2..exPrt4 - for MTML-4 cards and others
|
|
exPrt1..exPrt8 - for ML-8 cards.
|
|
inPrt1..inPrt8 - for MSL-8 and VF-30 card family.
|
|
MP-104/204: only exPrt3 (3) is applicable.
|
|
MP-4100: intPrt1...intPrt84 - for CLX cards.
|
|
For other products' index see their specification."
|
|
::= { prtExPh1MlCnfgEntry 3}
|
|
|
|
prtExPh1MlConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be considered
|
|
in any of the mux algorithms. It also affects all the card
|
|
considerations because it may indicate that the module has only
|
|
one physical interface."
|
|
::= {prtExPh1MlCnfgEntry 4}
|
|
|
|
prtExPh1MlLineType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
esfT1 (2), --> dsx1ESF
|
|
sfT1 (3), --> dsx1D4
|
|
g732nE1 (4), --> dsx1E1
|
|
g732nE1CRC (5), --> dsx1E1-CRC
|
|
g732sE1 (6), --> dsx1E1-MF
|
|
g732sE1CRC (7), --> dsx1E1-MF-CRC
|
|
g732unframed (8), --> dsx1Unframed, for T1 Unframed
|
|
e1Unframed (9), --> dsx1E1Unframed
|
|
framed (101)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the line type parameter for T1/E1 interface.
|
|
The user should select only the values which are relevant
|
|
to the specific port:
|
|
(2),(3), (8) - for T1 port
|
|
(4)..(7), (9) - for E1 port.
|
|
(101) framed - This value does not exist in standard MIB and is used
|
|
for a non-standard E1 port that doesn't has real framer.
|
|
Note: for old devices, g732unframed(8) was used as E1 Unframed.
|
|
That was because at the time this value did not exist in
|
|
the standard MIB (RFC-1406), so we added it in private MIB.
|
|
Now that it was added to standard MIB, private MIB was
|
|
updated as well.
|
|
This parameter has the same values as dsx1LineType in DS1
|
|
MIB (RFC-3895). The parameters in dsx1LineType are:
|
|
other (1)
|
|
esfT1 dsx1ESF (2)
|
|
sfT1 dsx1D4 (3)
|
|
g732nE1 dsx1E1 (4)
|
|
g732nE1CRC dsx1E1-CRC (5)
|
|
g732sE1 dsx1E1-MF (6)
|
|
g732sE1CRC dsx1E1-MF-CRC (7)
|
|
g732unframed dsx1Unframed (8) --from RFC-3895
|
|
e1Unframed dsx1E1Unframed (9) --from RFC-3895 "
|
|
::= { prtExPh1MlCnfgEntry 5}
|
|
|
|
prtExPh1MlLineCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
b7T1 (1), --> dsx1JBZS (for E1 & T1)
|
|
b8zsT1 (2), --> dsx1B8ZS (for E1 & T1)
|
|
transT1(3), --> dsx1AMI
|
|
hdb3E1 (4), --> dsx1HDB3 (for E1 & T1)
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the line code parameter used for T1/E1
|
|
interface.
|
|
The user should select only the parameters which are relevant
|
|
to the specific card:
|
|
T1 line code parameters for MPH.1/T1
|
|
E1 line code parameters for MPH.1/E1.
|
|
This parameter has the same values as dsx1LineCoding in T1/E1
|
|
MIB (RFC-1406). The parameters in dsx1LineCoding are:
|
|
dsx1JBZS (1)
|
|
dsx1B8ZS (2)
|
|
dsx1HDB3 (3)
|
|
dsx1ZBTSI (4)
|
|
dsx1AMI (5)
|
|
other (6)"
|
|
::= { prtExPh1MlCnfgEntry 6}
|
|
|
|
prtExPh1MlLineLen OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
len0p133ft (2),
|
|
len134p266ft (3),
|
|
len267p399ft (4),
|
|
len400p533ft (5),
|
|
len534p655ft (6),
|
|
lenFcc68 (7),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the line length parameter used only for T1/DSU
|
|
interfaces.
|
|
lenXXXpXXXft = len-XXX-XXXft."
|
|
::= { prtExPh1MlCnfgEntry 7}
|
|
|
|
prtExPh1MlRestoreTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
restoreT1secFast (2),
|
|
restoreT10sec62411 (3),
|
|
ccittE1 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time passing from the disappearance of the loss of
|
|
synchronization condition (red alarm) to the restoration of
|
|
normal service. The options 1secFast(2) and 10sec62411(3)
|
|
for E1 interfaces are proprietary implementation of the T1
|
|
standard to the E1 interface."
|
|
::= { prtExPh1MlCnfgEntry 8}
|
|
|
|
prtExPh1MlTxGain OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
txGain0db (2),
|
|
txGain7dot5db (3),
|
|
txGain15db (4),
|
|
txGain22dot5db (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the tx gain parameter used only for
|
|
T1/CSU interfaces."
|
|
::= { prtExPh1MlCnfgEntry 9}
|
|
|
|
prtExPh1MlRxSensitivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
low26dBm (2),
|
|
high36dBm (3),
|
|
shortHaul (4),
|
|
longHaul (5),
|
|
low15dbm (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the rx line sensitivity parameter.
|
|
low26dBm, high36dBm - applicable for T1-CSU
|
|
shortHaul, longHaul - applicable for MTML-4 cards
|
|
low15dbm was added for vmux110/210 T1 ports."
|
|
::= { prtExPh1MlCnfgEntry 10}
|
|
|
|
prtExPh1MlIdleCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines the code for transmission in empty time slots.
|
|
Type value(00-FFH), Excluding 0H,8H,10H,12H,21H,24H,42H,49H,
|
|
84H,92H"
|
|
::= { prtExPh1MlCnfgEntry 11}
|
|
|
|
prtExPh1MlTdmTrunk OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
linkA (1),
|
|
linkB (2),
|
|
none (3),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port is used to transfer
|
|
TDM cards data and through which Bus."
|
|
::= {prtExPh1MlCnfgEntry 12}
|
|
|
|
prtExPh1MlClkMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
internalLocal (1),
|
|
loopBackLocal (2),
|
|
nodalTiming (3),
|
|
loopBackFromLink (4),
|
|
loopBackFromChannel (5),
|
|
loopbackFromSystem (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the clock operation mode of the T1/E1 interface.
|
|
Ports that are connected to the TDM Buses must be in
|
|
nodalTiming(3) clock mode. "
|
|
::= {prtExPh1MlCnfgEntry 13}
|
|
|
|
prtExPh1MlMfClkSrcSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
local (2),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port Tx multiframe is
|
|
synchronized with Rx multiframe of another port and the slot
|
|
position of that port.
|
|
This operation is required in order to bypass signaling of
|
|
PCM voice channels. Its value is always local(2) when the port
|
|
isn't connected to any TDM bus. When it's value is local(2)
|
|
there is no meaning to 'prtExPh1MlMfClkSrcPrt' parameter.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid"
|
|
::= {prtExPh1MlCnfgEntry 14}
|
|
|
|
prtExPh1MlMfClkSrcPrt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
inPrt1 (101),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify a port position in the mux. It
|
|
has no effect when the prtExPh1MlMfClkSrcSlt selected is Local.
|
|
inPrt1 - for MTML-H/E1 cards."
|
|
::= {prtExPh1MlCnfgEntry 15}
|
|
|
|
prtExPh1MlFdlType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
response (2),
|
|
command (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify the side of the FDL operation.
|
|
Normal: 'response' for the user side and 'command' for the PTT
|
|
side.
|
|
Applicable only when working with ESF-T1 link"
|
|
::= {prtExPh1MlCnfgEntry 16}
|
|
|
|
prtExPh1MlInbandMng OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
fdlOrTs0 (3),
|
|
dedicatedTs (4),
|
|
dedicatedPpp (5),
|
|
dedicatedFr (6),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify an Inband management over the
|
|
link."
|
|
::= {prtExPh1MlCnfgEntry 17}
|
|
|
|
prtExPh1MlInbandMngRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
r4k (2),
|
|
r8k (3),
|
|
r12k (4),
|
|
r16k (5),
|
|
r32k (6),
|
|
r64k (7),
|
|
r20k (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify the rate of the Inband
|
|
management (Kbps).
|
|
E1 port - it is not applicable when prtExPh1MlInbandMng
|
|
selected is off.
|
|
T1 port - it is not applicable when prtExPh1MlInbandMng
|
|
selected is off OR fdlOrTs0."
|
|
::= {prtExPh1MlCnfgEntry 18}
|
|
|
|
prtExPh1MlRedundType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
dualCableAIS (2),
|
|
yCable (3),
|
|
dualCableParallelTx (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the ML redundancy type:
|
|
none - no ML redundacy
|
|
dualCableAIS - each ML card is connected by a separate
|
|
dualCableParallelTx cable to the other MUX (two cables
|
|
connect two MUXes). There are two
|
|
types of dual redundancy.
|
|
yCable - Y cable is connected to both ML cards (one cable
|
|
connects two MUXes).
|
|
Default=none
|
|
When only one ML card exists, the type can be only 'none'.
|
|
The value should be the same for both ML slots."
|
|
::= {prtExPh1MlCnfgEntry 19}
|
|
|
|
prtExPh1MlRedundSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the slot containing the redundacy ML
|
|
card, coupled with the current ML (prtExPh1MlSltIdx).
|
|
When prtExPh1MlRedundType=none (no ML redundancy) this
|
|
object will be 'notApplicable'.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid
|
|
When value is not 'none', it should be mutual to the
|
|
redundant ML slot."
|
|
::= {prtExPh1MlCnfgEntry 20}
|
|
|
|
prtExPh1MlRedundPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
exPrt3 (3),
|
|
exPrt4 (4),
|
|
inPrt1 (101),
|
|
inPrt2 (102),
|
|
inPrt3 (103),
|
|
inPrt4 (104),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the redundacy ML port, coupled with the
|
|
current ML port (prtExPh1MlPrtIdx).
|
|
When prtExPh1MlRedundType=none (no ML redundancy) this
|
|
object will be 'notApplicable'.
|
|
When value is not 'none', it should be mutual to the
|
|
redundant ML port.
|
|
inPrt1 - for MTML-H/E1 cards.
|
|
inPrt1..inPrt4 - for MTML-E2 cards.
|
|
exPrt2..exPrt4 - for MTML-4 cards."
|
|
::= {prtExPh1MlCnfgEntry 21}
|
|
|
|
prtExPh1MlRedundRecTime OBJECT-TYPE
|
|
SYNTAX Integer32 (1..99)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Redundancy Recovery Time (sec). After switching the ML card
|
|
to the current (prtExPh1MlSltIdx), the next ML switch can
|
|
be performed only after a minimum time, indicated by
|
|
this object."
|
|
::= {prtExPh1MlCnfgEntry 22}
|
|
|
|
prtExPh1MlInbandMngRoutProt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
rip2 (2),
|
|
proprietary (3),
|
|
proprietaryNoNmsTx (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Inband Mng routing protocol of
|
|
the port."
|
|
::= {prtExPh1MlCnfgEntry 23}
|
|
|
|
prtExPh1MlIfType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
csu (2),
|
|
dsu (3),
|
|
ltu (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface type of the port.
|
|
For T1 - csu, dsu are the valid values
|
|
For E1 - dsu, ltu are the valid values."
|
|
::= {prtExPh1MlCnfgEntry 24}
|
|
|
|
prtExPh1MlMultiplier OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
br56 (2),
|
|
br64 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The data rate of each TS. The multiplier values
|
|
can be 56 kbps or 64 kbps."
|
|
::= {prtExPh1MlCnfgEntry 25}
|
|
|
|
prtExPh1MlSupportedTS OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Supported Time Slots by the agent.
|
|
For Vmux-110 there is HW that supports less than 31/24
|
|
Time Slots for the E1/T1 port."
|
|
::= {prtExPh1MlCnfgEntry 26}
|
|
|
|
prtExPh1MlImpedance OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
unbalanced (2),
|
|
balanced (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Line Impedance.
|
|
For T1 (always balanced), impedance is 100 ohm.
|
|
For E1:
|
|
- balanced = 120 ohm
|
|
- unbalanced = 75 ohm."
|
|
::= {prtExPh1MlCnfgEntry 27}
|
|
|
|
prtExPh1MlQ50BwControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (2),
|
|
annexA (3),
|
|
annexB (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables configuration of Q.50 Bandwidth Control on the port.
|
|
If the bandwidth exceeds a certain threshold it is possible to disable
|
|
new calls in the PBX via Q.50 protocol.
|
|
|
|
Q.50 supports only E1 ports with Line Types:
|
|
E1-MF (G.732S), E1-CRC-MF(G.732SCRC )
|
|
It does not support T1 ports.
|
|
|
|
Annex A - the basic type of Q.50 which focuses only on the bandwidth control.
|
|
Can use one of the following pairs of signaling bits: A&B or C&D.
|
|
|
|
Annex B - Expansion of Annex A which includes also call release messages
|
|
and Maintenance Messages. Uses A&B bits only."
|
|
::= {prtExPh1MlCnfgEntry 28}
|
|
|
|
prtExPh1MlQ50SignalPair OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
aAndB (2),
|
|
cAndD (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Q.50 Signaling bits Pair that is currently in use:
|
|
A&B bits or C&D bits. For Annex B it will always be: aAndB (2)."
|
|
::= {prtExPh1MlCnfgEntry 29}
|
|
|
|
prtExPh1MlInternalSwitch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter shows whether the data will be transferred from one port to
|
|
the other port within the same group of 2 ports.
|
|
The default value is: Enable.
|
|
Disable value might be necessary for security implementations or
|
|
for ring applications.
|
|
|
|
For Vmux-2100 device this parameter is used on the Channelized Cards.
|
|
Both ports in each group should have the same value for this parameter."
|
|
::= {prtExPh1MlCnfgEntry 30}
|
|
|
|
prtExPh1MlSigService OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
normal (2),
|
|
advanced (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signaling Service given by this link.
|
|
notApplicable - for T1 links
|
|
normal - usual Signaling
|
|
advanced - V5 Signaling. "
|
|
::= {prtExPh1MlCnfgEntry 31}
|
|
|
|
prtExPh1MlFragmentSize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates the maximum number of bytes permitted in a packet send over the Link.
|
|
Exceeding this size will cause packet fragmentation."
|
|
::= {prtExPh1MlCnfgEntry 32}
|
|
--
|
|
-- MPH1.T1 & MPH1.E1
|
|
-- Time Slot Assignment Table
|
|
--
|
|
prtExPh1MlTsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExPh1MlTsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry, except prtExPh1MlTsTest that will be written
|
|
directly to the Active Configuration."
|
|
::= {prtPh1MlCnfg 2}
|
|
|
|
prtExPh1MlTsEntry OBJECT-TYPE
|
|
SYNTAX PrtExPh1MlTsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExPh1MlTsCnfgIdx, prtExPh1MlTsSltIdx, prtExPh1MlTsPrtIdx, prtExPh1MlTsIdx }
|
|
::= { prtExPh1MlTsTable 1}
|
|
|
|
PrtExPh1MlTsEntry ::=
|
|
SEQUENCE {
|
|
prtExPh1MlTsCnfgIdx Integer32,
|
|
prtExPh1MlTsSltIdx INTEGER,
|
|
prtExPh1MlTsPrtIdx INTEGER,
|
|
prtExPh1MlTsIdx Integer32,
|
|
prtExPh1MlTsIConSlot INTEGER,
|
|
prtExPh1MlTsIConPrt Integer32,
|
|
prtExPh1MlTsIConTs Integer32,
|
|
prtExPh1MlTsExt OBJECT IDENTIFIER,
|
|
prtExPh1MlTsTest INTEGER,
|
|
prtExPh1MlTsType INTEGER,
|
|
prtExPh1MlTsBundle Integer32,
|
|
prtExPh1MlTsTestDuration Integer32,
|
|
prtExPh1MlTsSubChType INTEGER,
|
|
prtExPh1MlTsSubChMask Integer32,
|
|
prtExPh1MlTsChRate INTEGER,
|
|
prtExPh1MlTsByteReversal INTEGER,
|
|
prtExPh1MlTsSigProfile INTEGER
|
|
}
|
|
|
|
prtExPh1MlTsCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtExPh1MlTsEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExPh1MlTsSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid.
|
|
For the Vmux2100 Main Board notApplicable (255) is used."
|
|
::= { prtExPh1MlTsEntry 2}
|
|
|
|
prtExPh1MlTsPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
exPrt3 (3),
|
|
exPrt4 (4),
|
|
exPrt5 (5),
|
|
exPrt6 (6),
|
|
exPrt7 (7),
|
|
exPrt8 (8),
|
|
exPrt9 (9),
|
|
exPrt10 (10),
|
|
exPrt11 (11),
|
|
exPrt12 (12),
|
|
exPrt13 (13),
|
|
exPrt14 (14),
|
|
exPrt15 (15),
|
|
exPrt16 (16),
|
|
exPrt17 (17),
|
|
exPrt18 (18),
|
|
|
|
inPrt1 (101),
|
|
inPrt2 (102),
|
|
inPrt3 (103),
|
|
inPrt4 (104),
|
|
inPrt5 (105),
|
|
inPrt6 (106),
|
|
inPrt7 (107),
|
|
inPrt8 (108),
|
|
inPrt9 (109),
|
|
inPrt10 (110),
|
|
inPrt11 (111),
|
|
inPrt12 (112),
|
|
inPrt13 (113),
|
|
inPrt14 (114),
|
|
inPrt15 (115),
|
|
inPrt16 (116),
|
|
inPrt17 (117),
|
|
inPrt18 (118),
|
|
inPrt19 (119),
|
|
inPrt20 (120) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
MPH.1/E1 and MPH.1/T1 cards have only one external interface.
|
|
exPrt2 - for ME1-2, MT1-2 and mhsPri cards.
|
|
exPrt3, exPrt4 - for mhsPri cards.
|
|
inPrt1 - for MTML-H/E1 cards."
|
|
::= { prtExPh1MlTsEntry 3}
|
|
|
|
prtExPh1MlTsIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique time slot position.
|
|
The valid time slots are 1..24 for T1 Card and
|
|
1..31 for E1 interface. In G732S-E1 lines time slot 16 is not
|
|
valid for data, it is dedicated for multiframe synchronization bits
|
|
and voice signaling."
|
|
::= { prtExPh1MlTsEntry 4}
|
|
|
|
prtExPh1MlTsIConSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
noConnect (2),
|
|
split (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the specified time slot is
|
|
connected/routed internally in the Agent and to which card
|
|
it is connected.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid.
|
|
split - will be used when the Src TS is connected to more
|
|
than one slot OR more than one port (each needing
|
|
less than a whole TS)."
|
|
::= {prtExPh1MlTsEntry 5}
|
|
|
|
prtExPh1MlTsIConPrt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the internally (In Mux)
|
|
connected/routed port.
|
|
For MP, the values will be:
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
exPrt11 (11) ,
|
|
exPrt12 (12) ,
|
|
|
|
noConnect (100),
|
|
|
|
inPrt1 (101) ,
|
|
inPrt2 (102) ,
|
|
inPrt3 (103) ,
|
|
inPrt4 (104) ,
|
|
inPrt5 (105) ,
|
|
inPrt6 (106) ,
|
|
inPrt7 (107) ,
|
|
inPrt8 (108) ,
|
|
inPrt9 (109) ,
|
|
inPrt10 (110) ,
|
|
inPrt11 (111) ,
|
|
inPrt12 (112)
|
|
}
|
|
For other products see specific values at spec."
|
|
::= {prtExPh1MlTsEntry 6}
|
|
|
|
prtExPh1MlTsIConTs OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique time slot position.
|
|
The valid time slots are 1..24 for T1 Card and
|
|
1..31 for E1 interface. In G732S-E1 lines time slot 16 is not
|
|
valid for data, it is dedicated to multiframe synchronization
|
|
and voice signaling."
|
|
::= {prtExPh1MlTsEntry 7}
|
|
|
|
prtExPh1MlTsExt OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A pointer to an extension of this table:
|
|
prtExTsSplitTable.
|
|
- If prtExPh1MlTsIConSlot='split', its value
|
|
should be set to the OBJECT IDENTIFIER of the
|
|
prtExTsSplitTable, with its relevant CnfgIdx,
|
|
SltIdx, PrtIdx, TsIdx and 1st TsBit.
|
|
- If prtExPh1MlTsIConSlot is not 'split', its value
|
|
should be set to the OBJECT IDENTIFIER { 0 0 }. "
|
|
::= { prtExPh1MlTsEntry 8 }
|
|
|
|
prtExPh1MlTsTest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
localLoop (2),
|
|
remoteLoop (3),
|
|
remoteBert (8), -- BERT
|
|
localToneInjection (9),
|
|
remoteToneInjection (18),
|
|
localBert (30),
|
|
split (254),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a test to be activated on the selected TS.
|
|
It is applicable only when prtSTstCmd=testPerTS(31).
|
|
notApplicable - when prtSTstCmd is NOT testPerTS(31).
|
|
none - no test is applied for the selected TS.
|
|
split - when the tests are per Bit of the selected TS."
|
|
::= { prtExPh1MlTsEntry 9 }
|
|
|
|
prtExPh1MlTsType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noConnect (2),
|
|
data (3),
|
|
voice (4),
|
|
cas (5),
|
|
ss7 (6),
|
|
transparent (7),
|
|
data2 (8),
|
|
data3 (9),
|
|
data4 (10),
|
|
ss7n2 (11),
|
|
hdlcV2Compatible (12),
|
|
subCh1 (13),
|
|
subCh2 (14),
|
|
subCh3 (15),
|
|
subCh4 (16),
|
|
subCh5 (17),
|
|
subCh6 (18),
|
|
subCh7 (19),
|
|
subCh8 (20),
|
|
trau (21),
|
|
qmux (22),
|
|
dynamic (23),
|
|
signaling (24),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Time Slot Type.
|
|
|
|
Transparent - means that the Time Slot will be Rx/Tx as is without processing it.
|
|
|
|
If the device requires more than 1 unique data or ss7 Time Slot,
|
|
options with numbers can be used like: data...data4.
|
|
Each numbered Type can go to a different destination.
|
|
ss7n2 - means the 2nd group of ss7 Time Slots.
|
|
data2,data3, data4 mean group 2,3,4 of Data Time Slots.
|
|
subCh1...subCh8 mean Sub Channel 1...8, respectively.
|
|
trau, qmux, dynamic, signaling - are used by GSM devices."
|
|
::= { prtExPh1MlTsEntry 10 }
|
|
|
|
prtExPh1MlTsBundle OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the bundle containing this Time Slot.
|
|
If no bundle exists for this TS or the bundle number
|
|
is irrelevant, the value will be 0."
|
|
::= { prtExPh1MlTsEntry 11 }
|
|
|
|
|
|
prtExPh1MlTsTestDuration OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the maximum duration of executing
|
|
a test on the specific TS. This entry applies to all the
|
|
test operations.
|
|
|
|
For the Vmux2100 the values are:
|
|
0 - 60 seconds.
|
|
|
|
A zero value specifies no time limitation.
|
|
When the test isn't active, the agent initiates this object to
|
|
2 when the duration is needed and to 0 if its not required.
|
|
The user should set this parameter after setting the
|
|
'prtExPh1MlTsTest' parameter."
|
|
::= { prtExPh1MlTsEntry 12 }
|
|
|
|
prtExPh1MlTsSubChType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
hdlc (1),
|
|
transparent (2),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Time Slot Sub-Channel Type.
|
|
This variable is relevant only when Time-Slot Type is SubCh
|
|
(e.g. prtExPh1MlTsType = subCh1...subCh8)."
|
|
::= { prtExPh1MlTsEntry 13 }
|
|
|
|
prtExPh1MlTsSubChMask OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Sub-Channel Type Mask.
|
|
This variable is relevant only when Time-Slot Type is SubCh
|
|
(e.g. prtExPh1MlTsType = subCh1...subCh8)."
|
|
::= { prtExPh1MlTsEntry 14 }
|
|
|
|
prtExPh1MlTsChRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
r16Kbps (2),
|
|
r32Kbps (3),
|
|
r64Kbps (4),
|
|
r8Kbps (5),
|
|
auto (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Rate of the Signaling Channel.
|
|
notApplicable(1) when TS Type is other than Signaling or Transparent"
|
|
::= { prtExPh1MlTsEntry 15 }
|
|
|
|
prtExPh1MlTsByteReversal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Byte Reversal.
|
|
This variable defines whether the LSB or MSB is transmitted first.
|
|
no(2) - MSB is transmitted first
|
|
yes(3) - LSB is transmitted first."
|
|
::= { prtExPh1MlTsEntry 16 }
|
|
|
|
prtExPh1MlTsSigProfile OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
-- none (2),
|
|
p1 (3),
|
|
p2 (4),
|
|
p3 (5),
|
|
p4 (6),
|
|
p5 (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Signaling Profile of the port.
|
|
It is applicable only when prtMl4SigProfile=perTS.
|
|
p1 = profile 1
|
|
p2 = profile 2
|
|
p3 = profile 3
|
|
p4 = profile 4
|
|
p5 = profile 5 "
|
|
::= { prtExPh1MlTsEntry 17 }
|
|
|
|
--
|
|
-- MPH.1/T1 & MPH.1/E1
|
|
-- Internal port objects table
|
|
-- (only for the Hybrid modules)
|
|
--
|
|
prtInPh1MlCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtInPh1MlCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtPh1MlCnfg 3}
|
|
|
|
prtInPh1MlCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtInPh1MlCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtInPh1MlCnfgIdx, prtInPh1MlSltType, prtInPh1MlPrtIdx }
|
|
::= { prtInPh1MlCnfgTable 1}
|
|
|
|
PrtInPh1MlCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtInPh1MlCnfgIdx Integer32,
|
|
prtInPh1MlSltType INTEGER,
|
|
prtInPh1MlPrtIdx Integer32,
|
|
prtInPh1MlConnect INTEGER,
|
|
prtInPh1MlRate INTEGER,
|
|
prtInPh1MlProtocol INTEGER,
|
|
prtInPh1MlConnectionTyp INTEGER,
|
|
prtInPh1MlCongResponse INTEGER,
|
|
prtInPh1MlCongLevel Integer32,
|
|
prtInPh1MlTc INTEGER,
|
|
prtInPh1MlFlowControl INTEGER,
|
|
prtInPh1MlSegment INTEGER,
|
|
prtInPh1MlFrMngProt INTEGER,
|
|
prtInPh1MlEnqPeriod Integer32,
|
|
prtInPh1MlFullRptPeriod Integer32,
|
|
prtInPh1MlFrWindowSize Integer32,
|
|
prtInPh1MlErrorsThreshold Integer32,
|
|
prtInPh1MlMaxIdleTime Integer32,
|
|
prtInPh1MlBearerCh INTEGER,
|
|
prtInPh1MlAssociatedExCh INTEGER,
|
|
prtInPh1MlClockEncoding INTEGER,
|
|
prtInPh1MlMinSeparators Integer32,
|
|
prtInPh1MlCcittCrc INTEGER,
|
|
prtInPh1MlFrameSeparator INTEGER
|
|
}
|
|
|
|
|
|
prtInPh1MlCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtInPh1MlCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtInPh1MlSltType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
For ISDN BRI port of MX300/30:
|
|
io1(5) = isdn1(5) and io2(6) = isdn2(6)
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
|
|
::= { prtInPh1MlCnfgEntry 2}
|
|
|
|
prtInPh1MlPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
MPH.1/E1 and MPH.1/T1 cards have three internal interfaces.
|
|
MX3000 modules may have up to 50 internal ports."
|
|
::= { prtInPh1MlCnfgEntry 3}
|
|
|
|
prtInPh1MlConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= { prtInPh1MlCnfgEntry 4}
|
|
|
|
prtInPh1MlRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r1x56eq56Kbps (1),
|
|
r1x64eq64Kbps (2),
|
|
r2x56eq112Kbps (3),
|
|
r2x64eq128Kbps (4),
|
|
r3x56eq168Kbps (5),
|
|
r3x64eq192Kbps (6),
|
|
r4x56eq224Kbps (7),
|
|
r4x64eq256Kbps (8),
|
|
r5x56eq280Kbps (9),
|
|
r5x64eq320Kbps (10),
|
|
r6x56eq336Kbps (11),
|
|
r6x64eq384Kbps (12),
|
|
r7x56eq392Kbps (13),
|
|
r7x64eq448Kbps (14),
|
|
r8x56eq448Kbps (15),
|
|
r8x64eq512Kbps (16),
|
|
r9x56eq504Kbps (17),
|
|
r9x64eq576Kbps (18),
|
|
r10x56eq560Kbps (19),
|
|
r10x64eq640Kbps (20),
|
|
r11x56eq616Kbps (21),
|
|
r11x64eq704Kbps (22),
|
|
r12x56eq672Kbps (23),
|
|
r12x64eq768Kbps (24),
|
|
r13x56eq728Kbps (25),
|
|
r13x64eq832Kbps (26),
|
|
r14x56eq784Kbps (27),
|
|
r14x64eq896Kbps (28),
|
|
r15x56eq840Kbps (29),
|
|
r15x64eq960Kbps (30),
|
|
r16x56eq896Kbps (31),
|
|
r16x64eq1024Kbps(32),
|
|
r17x56eq952Kbps (33),
|
|
r17x64eq1088Kbps(34),
|
|
r18x56eq1008Kbps(35),
|
|
r18x64eq1152Kbps(36),
|
|
r19x56eq1064Kbps(37),
|
|
r19x64eq1216Kbps(38),
|
|
r20x56eq1120Kbps(39),
|
|
r20x64eq1280Kbps(40),
|
|
r21x56eq1176Kbps(41),
|
|
r21x64eq1344Kbps(42),
|
|
r22x56eq1232Kbps(43),
|
|
r22x64eq1408Kbps(44),
|
|
r23x56eq1288Kbps(45),
|
|
r23x64eq1472Kbps(46),
|
|
r24x56eq1344Kbps(47),
|
|
r24x64eq1536Kbps(48),
|
|
r25x56eq1400Kbps(49),
|
|
r25x64eq1600Kbps(50),
|
|
r26x56eq1456Kbps(51),
|
|
r26x64eq1664Kbps(52),
|
|
r27x56eq1512Kbps(53),
|
|
r27x64eq1728Kbps(54),
|
|
r28x56eq1568Kbps(55),
|
|
r28x64eq1792Kbps(56),
|
|
r29x56eq1624Kbps(57),
|
|
r29x64eq1856Kbps(58),
|
|
r30x56eq1680Kbps(59),
|
|
r30x64eq1920Kbps(60),
|
|
r31x56eq1736Kbps(61),
|
|
r31x64eq1984Kbps(62),
|
|
r32x56eq1792Kbps(63),
|
|
r32x64eq2048Kbps(64),
|
|
r1x1dot5eq1dot5M(65),
|
|
r2x1dot5eq3M (66),
|
|
r3x1dot5eq4dot5M(67),
|
|
r4x1dot5eq6M (68),
|
|
r5x1dot5eq7dot5M(69),
|
|
r6x1dot5eq9M (70),
|
|
r7x1dot5eq10dot5M(71),
|
|
r8x1dot5eq12M (72),
|
|
r1x2Meq2M (73),
|
|
r2x2Meq4M (74),
|
|
r3x2Meq6M (75),
|
|
r4x2Meq8M (76),
|
|
r5x2Meq10M (77),
|
|
r6x2Meq12M (78),
|
|
r7x2Meq14M (79),
|
|
r8x2Meq16M (80),
|
|
noRate (100)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the port speed. "
|
|
::= { prtInPh1MlCnfgEntry 5}
|
|
|
|
prtInPh1MlProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fr (1),
|
|
frPlus (2),
|
|
pCellRelay (3),
|
|
hdlcSdlc (4),
|
|
transparentHdlc (5),
|
|
ciscoBridgedEth (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the applied protocol."
|
|
::= { prtInPh1MlCnfgEntry 6}
|
|
|
|
prtInPh1MlConnectionTyp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
sameNetManaged (1),
|
|
sameNetNotMana (2),
|
|
user (3),
|
|
otherNet (4),
|
|
pubNet (5),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the link connection type.
|
|
It is required for three reasons:
|
|
FR/CR Inband management operation (LMI,CLMM...).
|
|
CIR check.
|
|
NMS network management.
|
|
|
|
SameNetManaged - indicates network internal line.
|
|
SameNetNotMana - indicates network internal line, but the remote
|
|
mux is not managed by the nms.
|
|
|
|
User - User to Network Interface.
|
|
OtherNet - Network To Network Interfce.
|
|
PubNet - Access Mux To PubNet Interface."
|
|
::= { prtInPh1MlCnfgEntry 7}
|
|
|
|
prtInPh1MlCongResponse OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
flowControl (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates how to handle the congestion indication
|
|
to/from the mux internal connection side (for example
|
|
transmit/receive becn to/from the network).
|
|
no - do nothing
|
|
FlowControl - translate the congestion indication between the
|
|
port and the internal connection port according to
|
|
the definition of the prtInPh1MlFlowControl
|
|
parameters. The operation is done in both directions."
|
|
::= { prtInPh1MlCnfgEntry 8}
|
|
|
|
prtInPh1MlCongLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the level of delayed data in
|
|
precents of the total available dynamic memory,
|
|
for which the port will start to operate .
|
|
The resolution of the parameter is 5 percent.
|
|
Valid values: 10..70, 255.
|
|
255=notApplicable."
|
|
::= { prtInPh1MlCnfgEntry 9}
|
|
|
|
prtInPh1MlTc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
tc1sec (1),
|
|
tc2sec (2),
|
|
tc3sec (3),
|
|
tc4sec (4),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Tc parameter which is the time
|
|
period of the sliding window in which the Bc/Be are tested.
|
|
The value of this parameter is identical for all the ports in the
|
|
specific card.
|
|
255=notApplicable."
|
|
::= { prtInPh1MlCnfgEntry 10}
|
|
|
|
prtInPh1MlFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (2),
|
|
fecnBecn (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the required flow control betweeen
|
|
the port and the remote equipment."
|
|
::= { prtInPh1MlCnfgEntry 11}
|
|
|
|
prtInPh1MlSegment OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
s36Byte (2),
|
|
s150Byte (3),
|
|
s264Byte (4),
|
|
s378Byte (5),
|
|
s492Byte (6),
|
|
s236Byte (7),
|
|
s472Byte (8),
|
|
s708Byte (9),
|
|
s944Byte (10),
|
|
s1180Byte (11)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the Segmentation in Bytes.
|
|
In protocol FR+, ISDN internals, MX 30/300 the segmentation is:
|
|
|
|
50 (2) ,158 (3) ,266 (4) ,376 (5), 484 (6)
|
|
|
|
In MX 3000/4:
|
|
For protocol FR+ (internal ISDN ports of MHS.S, MHS.U, MHS.E1, MHS.T1
|
|
cards) segmentation values are:
|
|
|
|
236 (7),472 (8), 708 (9), 944 (10) ,1180 (11)"
|
|
|
|
::= { prtInPh1MlCnfgEntry 12}
|
|
|
|
prtInPh1MlFrMngProt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
lmi (3),
|
|
ansiT1 (4), --Annex D
|
|
annexA (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Frame-Relay management protocol.
|
|
ansiT1 = ANSI T1.617 Annex D (this is the default value).
|
|
This parameter is applicable only for FR and FR+ protocols.
|
|
When prtInPh1MlConnectionTyp = sameNetManaged, this object
|
|
will be RO (internally determined). "
|
|
::= { prtInPh1MlCnfgEntry 13}
|
|
|
|
prtInPh1MlEnqPeriod OBJECT-TYPE
|
|
SYNTAX Integer32 (0..30)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the Status Enquiry Period, in seconds.
|
|
It determines the frequency of the Status Enquiry message
|
|
as sent by the FR user side.
|
|
At the FR network side, it determines the timeout for this
|
|
message reception.
|
|
Default = 4 seconds.
|
|
This parameter is applicable only for FR and FR+ protocols
|
|
AND
|
|
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
|
|
0=notApplicable."
|
|
::= { prtInPh1MlCnfgEntry 14}
|
|
|
|
prtInPh1MlFullRptPeriod OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the Full Report Frequency.
|
|
It determines the number of the Status Enquiry messages
|
|
sent by the FR user side, before a Full Report Request is
|
|
sent.
|
|
The units are : Status Enquiry messages (periods).
|
|
Valid values: 1 .. 255.
|
|
255 = infinite (never sent).
|
|
This parameter is applicable only for FR and FR+ protocols
|
|
AND
|
|
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
|
|
0=notApplicable."
|
|
::= { prtInPh1MlCnfgEntry 15}
|
|
|
|
prtInPh1MlFrWindowSize OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the FR Window Size.
|
|
It determines the number of samplings in the sliding window
|
|
that counts the errors.
|
|
This parameter is applicable only for FR and FR+ protocols
|
|
AND
|
|
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
|
|
0=notApplicable."
|
|
::= { prtInPh1MlCnfgEntry 16}
|
|
|
|
prtInPh1MlErrorsThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the Max Errors.
|
|
It determines the number of Status Enquiry Errors that
|
|
occured within the FR sliding window, before this port is
|
|
considered DOWN (threshold).
|
|
This parameter is applicable only for FR and FR+ protocols
|
|
AND
|
|
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
|
|
0=notApplicable. "
|
|
::= { prtInPh1MlCnfgEntry 17}
|
|
|
|
prtInPh1MlMaxIdleTime OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1800)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Move to higher prioritized connected link after this period of
|
|
seconds of silence on the current link.
|
|
0=Never. Never move to higher prioritized connected link.
|
|
UNIT is seconds.
|
|
Valid values are: 0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 120, 180, 240, 300,
|
|
360, 420, 480, 540, 600, 900, 1200, 1500, 1800.
|
|
Attempt to Set an invalid value will result in getting the default value."
|
|
DEFVAL { 10 }
|
|
::= {prtInPh1MlCnfgEntry 18}
|
|
|
|
prtInPh1MlBearerCh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
channelB1 (3),
|
|
channelB2 (4),
|
|
chB1andchB2 (5),
|
|
none (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines which B (bearer) channels are used for transferring ISDN data.
|
|
Default value is: none (255).
|
|
anyChannel (2) is skipped because it is not in use here."
|
|
::= {prtInPh1MlCnfgEntry 19}
|
|
|
|
prtInPh1MlAssociatedExCh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
exPrt3 (3),
|
|
exPrt4 (4),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the external port associated to this internal
|
|
port. At present, it is used by the Hybrid (mp2100h), MHS-4 cards which
|
|
can have up to 64 dynamic internal ports associated with External ports.
|
|
|
|
For ISDN cards, the value will be: notApplicable (255).
|
|
The associated external of an ISDN internal port is represented
|
|
by the MIB object: prtIsdnDirectoryPrtNu."
|
|
::= { prtInPh1MlCnfgEntry 20}
|
|
|
|
prtInPh1MlClockEncoding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
nrz (2),
|
|
nrzI (3),
|
|
fm0 (4),
|
|
manchester (5),
|
|
diffManchester(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the Encoding type of the Line.
|
|
This parameter is applicable only for FR and FR+ protocols."
|
|
::= { prtInPh1MlCnfgEntry 21}
|
|
|
|
prtInPh1MlMinSeparators OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum number of bytes separating between two adjacent frames (HDLC item).
|
|
0 = notApplicable"
|
|
::= { prtInPh1MlCnfgEntry 22}
|
|
|
|
prtInPh1MlCcittCrc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
crc16 (2),
|
|
crc32 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates how many Bits are used for CRC (HDLC item)."
|
|
::= { prtInPh1MlCnfgEntry 23}
|
|
|
|
prtInPh1MlFrameSeparator OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
idles (2),
|
|
flags (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates what should be transferred on the line when there
|
|
are no frames to pass (HDLC item).
|
|
idles: mean that FF will pass on the line
|
|
flags: mean that 7E will pass on the line."
|
|
::= { prtInPh1MlCnfgEntry 24}
|
|
|
|
|
|
--
|
|
-- MPH1.T1 & MPH1.E1
|
|
-- Internal port Dlci objects table
|
|
--
|
|
|
|
prtInPh1MlDlciTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtInPh1MlDlciEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtPh1MlCnfg 4}
|
|
|
|
prtInPh1MlDlciEntry OBJECT-TYPE
|
|
SYNTAX PrtInPh1MlDlciEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtInPh1MlDlciCnfgIdx, prtInPh1MlDlciSltIdx, prtInPh1MlDlciPrtIdx, prtInPh1MlDlciIdx }
|
|
::= { prtInPh1MlDlciTable 1}
|
|
|
|
PrtInPh1MlDlciEntry ::=
|
|
SEQUENCE {
|
|
prtInPh1MlDlciCnfgIdx Integer32,
|
|
prtInPh1MlDlciSltIdx INTEGER,
|
|
prtInPh1MlDlciPrtIdx INTEGER,
|
|
prtInPh1MlDlciIdx Integer32,
|
|
|
|
prtInPh1MlDlciValid INTEGER,
|
|
prtInPh1MlDlciIConSlt INTEGER,
|
|
prtInPh1MlDlciIConPrt INTEGER,
|
|
prtInPh1MlDlciIConDlci Integer32,
|
|
|
|
prtInPh1MlDlciTxBc INTEGER,
|
|
prtInPh1MlDlciTxBe INTEGER,
|
|
prtInPh1MlDlciRxBc INTEGER,
|
|
prtInPh1MlDlciRxBe INTEGER,
|
|
|
|
prtInPh1MlDlciPriority Integer32,
|
|
|
|
prtInPh1MlDlciStatus INTEGER
|
|
}
|
|
|
|
|
|
prtInPh1MlDlciCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtInPh1MlDlciEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtInPh1MlDlciSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid"
|
|
::= { prtInPh1MlDlciEntry 2}
|
|
|
|
prtInPh1MlDlciPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inPrt1 (101) ,
|
|
inPrt2 (102) ,
|
|
inPrt3 (103)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique internal port number.
|
|
MPH.1/E1 and MPH.1/T1 cards have three internal ports."
|
|
::= { prtInPh1MlDlciEntry 3}
|
|
|
|
prtInPh1MlDlciIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..991)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique index for each possible
|
|
used dlci(16..991). When the protocol is not Multiplexing
|
|
protocol, then its type is 'user' and the only valid index
|
|
is 1."
|
|
::= { prtInPh1MlDlciEntry 4}
|
|
|
|
prtInPh1MlDlciValid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the attributes in this entry
|
|
are valid or not. The user can add/delete pvc (dlci to dlci
|
|
connection) by modifing this object"
|
|
::= { prtInPh1MlDlciEntry 5}
|
|
|
|
prtInPh1MlDlciIConSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noConnect(2),
|
|
cl (3),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position In the Mux
|
|
(Agent) where the dlci is routed to.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid"
|
|
::= { prtInPh1MlDlciEntry 6}
|
|
|
|
prtInPh1MlDlciIConPrt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
clNMS (99) ,
|
|
noConnect (100),
|
|
inPrt1 (101) ,
|
|
inPrt2 (102) ,
|
|
inPrt3 (103) ,
|
|
inPrt4 (104) ,
|
|
inPrt5 (105) ,
|
|
inPrt6 (106) ,
|
|
inPrt7 (107) ,
|
|
inPrt8 (108) ,
|
|
inPrt9 (109) ,
|
|
inPrt10 (110) ,
|
|
inPrt11 (111) ,
|
|
inPrt12 (112)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port id which the dlci is
|
|
routed to."
|
|
::= { prtInPh1MlDlciEntry 7}
|
|
|
|
|
|
prtInPh1MlDlciIConDlci OBJECT-TYPE
|
|
SYNTAX Integer32 (1..991)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique internal connection dlci
|
|
number which the src dlci is routed to."
|
|
::= { prtInPh1MlDlciEntry 8}
|
|
|
|
prtInPh1MlDlciTxBc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
txBc9600bps (3),
|
|
txBc14200bps (4),
|
|
txBc19200bps (5),
|
|
txBc28800bps (6),
|
|
txBc32000bps (7),
|
|
txBc38400bps (8),
|
|
txBc48000bps (9),
|
|
txBc56000bps (10),
|
|
txBc57600bps (11),
|
|
txBc64Kbps (12),
|
|
txBc128Kbps (13),
|
|
txBc192Kbps (14),
|
|
txBc256Kbps (15),
|
|
txBc320Kbps (16),
|
|
txBc384Kbps (17),
|
|
txBc448Kbps (18),
|
|
txBc512Kbps (19),
|
|
txBc768Kbps (20),
|
|
txBc1024Kbps (21)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Tx committed bandwidth on
|
|
the user transmit line or at the port receive line."
|
|
::= { prtInPh1MlDlciEntry 9}
|
|
|
|
|
|
prtInPh1MlDlciTxBe OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
txBe9600bps (3),
|
|
txBe14200bps (4),
|
|
txBe19200bps (5),
|
|
txBe28800bps (6),
|
|
txBe32000bps (7),
|
|
txBe38400bps (8),
|
|
txBe48000bps (9),
|
|
txBe56000bps (10),
|
|
txBe57600bps (11),
|
|
txBe64Kbps (12),
|
|
txBe128Kbps (13),
|
|
txBe192Kbps (14),
|
|
txBe256Kbps (15),
|
|
txBe320Kbps (16),
|
|
txBe384Kbps (17),
|
|
txBe448Kbps (18),
|
|
txBe512Kbps (19),
|
|
txBe768Kbps (20),
|
|
txBe1024Kbps (21)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Tx excess bandwidth on the
|
|
user transmit line or at the port receive line."
|
|
::= { prtInPh1MlDlciEntry 10}
|
|
|
|
|
|
prtInPh1MlDlciRxBc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
rxBc9600bps (3),
|
|
rxBc14200bps (4),
|
|
rxBc19200bps (5),
|
|
rxBc28800bps (6),
|
|
rxBc32000bps (7),
|
|
rxBc38400bps (8),
|
|
rxBc48000bps (9),
|
|
rxBc56000bps (10),
|
|
rxBc57600bps (11),
|
|
rxBc64Kbps (12),
|
|
rxBc128Kbps (13),
|
|
rxBc192Kbps (14),
|
|
rxBc256Kbps (15),
|
|
rxBc320Kbps (16),
|
|
rxBc384Kbps (17),
|
|
rxBc448Kbps (18),
|
|
rxBc512Kbps (19),
|
|
rxBc768Kbps (20),
|
|
rxBc1024Kbps (21)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Rx committed bandwidth on
|
|
the user receive line or at the port transmit line."
|
|
::= { prtInPh1MlDlciEntry 11}
|
|
|
|
|
|
prtInPh1MlDlciRxBe OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
rxBe9600bps (3),
|
|
rxBe14200bps (4),
|
|
rxBe19200bps (5),
|
|
rxBe28800bps (6),
|
|
rxBe32000bps (7),
|
|
rxBe38400bps (8),
|
|
rxBe48000bps (9),
|
|
rxBe56000bps (10),
|
|
rxBe57600bps (11),
|
|
rxBe64Kbps (12),
|
|
rxBe128Kbps (13),
|
|
rxBe192Kbps (14),
|
|
rxBe256Kbps (15),
|
|
rxBe320Kbps (16),
|
|
rxBe384Kbps (17),
|
|
rxBe448Kbps (18),
|
|
rxBe512Kbps (19),
|
|
rxBe768Kbps (20),
|
|
rxBe1024Kbps (21)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Rx excess bandwidth on the
|
|
user receive line or at the port transmit line."
|
|
::= { prtInPh1MlDlciEntry 12}
|
|
|
|
|
|
prtInPh1MlDlciPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique priority of the pcv.
|
|
1 is the lowest priority and 8 is the highest priority."
|
|
::= { prtInPh1MlDlciEntry 13}
|
|
|
|
|
|
|
|
prtInPh1MlDlciStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disconnected (1),
|
|
connected (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the status of the pvc. The status is
|
|
disconnected(1) when one of the sides is programmed as
|
|
not connected"
|
|
::= { prtInPh1MlDlciEntry 14}
|
|
|
|
|
|
--
|
|
-- ML-20 - High Speed Main Link card
|
|
-- External Port Objects
|
|
--
|
|
prtPhMlCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtPhMlCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtPh1MlCnfg 5}
|
|
|
|
prtPhMlCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtPhMlCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtPhMlCnfgIdx, prtPhMlSltIdx, prtPhMlPrtIdx }
|
|
::= { prtPhMlCnfgTable 1}
|
|
|
|
PrtPhMlCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtPhMlCnfgIdx Integer32,
|
|
prtPhMlSltIdx INTEGER,
|
|
prtPhMlPrtIdx INTEGER,
|
|
prtPhMlConnect INTEGER,
|
|
prtPhMlRate INTEGER,
|
|
prtPhMlCAS INTEGER,
|
|
prtPhMlClockMode INTEGER,
|
|
prtPhMlSatBuffer INTEGER,
|
|
prtPhMlDialProcess INTEGER,
|
|
prtPhMlSyncRestore Integer32,
|
|
prtPhMlBus INTEGER,
|
|
prtPhMlMfSyncSlot INTEGER,
|
|
prtPhMlClockSource INTEGER,
|
|
prtPhMlErrCorrection INTEGER,
|
|
prtPhMlCorrectionMode INTEGER,
|
|
prtPhMlControlSignals INTEGER,
|
|
prtPhMlInterfaceType INTEGER,
|
|
prtPhMlClockPolarity INTEGER
|
|
}
|
|
|
|
|
|
prtPhMlCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtPhMlCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtPhMlSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the module is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
|
|
|
|
For the Vmux2100 Main Board notApplicable (1) is used."
|
|
::= { prtPhMlCnfgEntry 2}
|
|
|
|
prtPhMlPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
ML-20 cards have just one external interface."
|
|
::= { prtPhMlCnfgEntry 3}
|
|
|
|
prtPhMlConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be considered
|
|
in any of the mux algorithms."
|
|
::= {prtPhMlCnfgEntry 4}
|
|
|
|
prtPhMlRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r1x64eq64Kbps (2),
|
|
r2x64eq128Kbps (4),
|
|
r3x64eq192Kbps (6),
|
|
r4x64eq256Kbps (8),
|
|
r5x64eq320Kbps (10),
|
|
r6x64eq384Kbps (12),
|
|
r7x64eq448Kbps (14),
|
|
r8x64eq512Kbps (16),
|
|
r9x64eq576Kbps (18),
|
|
r10x64eq640Kbps (20),
|
|
r11x64eq704Kbps (22),
|
|
r12x64eq768Kbps (24),
|
|
r13x64eq832Kbps (26),
|
|
r14x64eq896Kbps (28),
|
|
r15x64eq960Kbps (30),
|
|
r16x64eq1024Kbps(32),
|
|
r17x64eq1088Kbps(34),
|
|
r18x64eq1152Kbps(36),
|
|
r19x64eq1216Kbps(38),
|
|
r20x64eq1280Kbps(40),
|
|
r21x64eq1344Kbps(42),
|
|
r22x64eq1408Kbps(44),
|
|
r23x64eq1472Kbps(46),
|
|
r24x64eq1536Kbps(48),
|
|
r25x64eq1600Kbps(50),
|
|
r26x64eq1664Kbps(52),
|
|
r27x64eq1728Kbps(54),
|
|
r28x64eq1792Kbps(56),
|
|
r29x64eq1856Kbps(58),
|
|
r30x64eq1920Kbps(60),
|
|
r31x64eq1984Kbps(62),
|
|
r32x64eq2048Kbps(64),
|
|
auto (70)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the configured port speed.
|
|
auto - rate is adapted automatically to the attached modem rate."
|
|
::= {prtPhMlCnfgEntry 5}
|
|
|
|
prtPhMlCAS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether Channel Associated
|
|
Signaling (CAS) is used."
|
|
::= {prtPhMlCnfgEntry 6}
|
|
|
|
prtPhMlClockMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dce (2),
|
|
ext-dce (3),
|
|
dte (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock mode."
|
|
::= { prtPhMlCnfgEntry 7}
|
|
|
|
prtPhMlSatBuffer OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Satellite Buffer (+/- 256)."
|
|
::= {prtPhMlCnfgEntry 8}
|
|
|
|
prtPhMlDialProcess OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
callIn (3),
|
|
callOut (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dial Process."
|
|
::= {prtPhMlCnfgEntry 9}
|
|
|
|
prtPhMlSyncRestore OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sync Restoration time, in seconds.
|
|
notApplicable=0. "
|
|
::= {prtPhMlCnfgEntry 10}
|
|
|
|
prtPhMlBus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
busA (2),
|
|
busB (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TDM BUS this port is linked to."
|
|
::= {prtPhMlCnfgEntry 11}
|
|
|
|
prtPhMlMfSyncSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (2),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the sync is synchronized
|
|
according to a certain card and the slot of this card.
|
|
This operation is required in order to bypass signaling of
|
|
PCM voice channels.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
|
|
::= {prtPhMlCnfgEntry 12}
|
|
|
|
prtPhMlClockSource OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
txClock (2),
|
|
rxClock (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Clock Source: TC (Tx Clock) or RC (Rx Clock) signals."
|
|
::= {prtPhMlCnfgEntry 13}
|
|
|
|
prtPhMlErrCorrection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if Error Correction mechanism should be applied or not.
|
|
It will be applicable only if the interface HW includes the Error Correction
|
|
chip."
|
|
::= {prtPhMlCnfgEntry 14}
|
|
|
|
prtPhMlCorrectionMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
random (2),
|
|
bursty (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only when prtPhMlErrCorrection=yes.
|
|
random - enables to correct up to 3 random errors in an 23 bit frame
|
|
built from 12 data bits and 11 appended parity bits.
|
|
bursty - interleaving 3 frames, allows correcting bursts of 9 bit length."
|
|
::= {prtPhMlCnfgEntry 15}
|
|
|
|
|
|
prtPhMlControlSignals OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
ignore (2),
|
|
implement (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows whether the Port will ignore or implement the control signals
|
|
like DCD, CTS, DTR."
|
|
::= {prtPhMlCnfgEntry 16}
|
|
|
|
prtPhMlInterfaceType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
v35 (2),
|
|
x21 (3), -- v.11
|
|
rs232 (4), -- v.28
|
|
rs449 (5),
|
|
ei530 (6),
|
|
ei530a (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SW Configurable Interface Type."
|
|
::= {prtPhMlCnfgEntry 17}
|
|
|
|
prtPhMlClockPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
normal (2),
|
|
inverted (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the clock polarity."
|
|
::= {prtPhMlCnfgEntry 18}
|
|
|
|
-- This table is an extension for new version of MAXcess
|
|
-- modules.
|
|
prtLogicalCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtLogicalCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtLogicalCnfg 1}
|
|
|
|
prtLogicalCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtLogicalCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtLogicalCnfgIdx, prtLogicalSltIdx, prtLogicalPrtIdx }
|
|
::= { prtLogicalCnfgTable 1}
|
|
|
|
PrtLogicalCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtLogicalCnfgIdx Integer32,
|
|
prtLogicalSltIdx INTEGER,
|
|
prtLogicalPrtIdx Integer32,
|
|
prtLogicalConnect INTEGER,
|
|
prtLogicalFunction INTEGER,
|
|
prtLogicalRowStatus RowStatus
|
|
}
|
|
|
|
prtLogicalCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtLogicalCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtLogicalSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot Index.
|
|
For ISDN BRI Ports of MX300/30,
|
|
io1(5) = isdn1(5) and io2(6) = isdn2(6)."
|
|
::= { prtLogicalCnfgEntry 2}
|
|
|
|
prtLogicalPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
This port number should be an internal port number:
|
|
inPrt1(101)->inPrt50(150), linkSel1(200)->linkSel50(250),
|
|
encaps1(300)-> encaps50(350), huntGr1(101) -> huntGr10(110)."
|
|
::= { prtLogicalCnfgEntry 3}
|
|
|
|
prtLogicalConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be considered
|
|
in any of the mux algorithms."
|
|
::= { prtLogicalCnfgEntry 4}
|
|
|
|
prtLogicalFunction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
linkSelector(2),
|
|
encapsulator(3),
|
|
huntGroup(4)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter defines the function of the relevant channel."
|
|
::= { prtLogicalCnfgEntry 5 }
|
|
|
|
prtLogicalRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter allows the NMS to create/delete logical ports.
|
|
The only possible supported RowStatus vaules are
|
|
active (1) and destroy (6)."
|
|
::= { prtLogicalCnfgEntry 6 }
|
|
|
|
|
|
-- This group contains management information for the
|
|
-- link selector function.
|
|
|
|
linkSelectorCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LinkSelectorCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtLogicalCnfg 2}
|
|
|
|
linkSelectorCnfgEntry OBJECT-TYPE
|
|
SYNTAX LinkSelectorCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {linkSelectorCnfgIdx, linkSelectorSltIdx, linkSelectorPrtIdx }
|
|
::= { linkSelectorCnfgTable 1}
|
|
|
|
LinkSelectorCnfgEntry ::=
|
|
SEQUENCE {
|
|
linkSelectorCnfgIdx Integer32,
|
|
linkSelectorSltIdx INTEGER,
|
|
linkSelectorPrtIdx Integer32,
|
|
linkSelectorMaxIdleTime Integer32,
|
|
linkSelectorMode INTEGER,
|
|
linkSelectorRevert INTEGER,
|
|
linkSelectorMinBUSession Integer32
|
|
}
|
|
|
|
linkSelectorCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of
|
|
the Cnfg (1..100) being accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { linkSelectorCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
linkSelectorSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot Index"
|
|
::= { linkSelectorCnfgEntry 2}
|
|
|
|
linkSelectorPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
This port number should be internal port number:
|
|
higher or equal to linkSeL1(201)."
|
|
::= { linkSelectorCnfgEntry 3}
|
|
|
|
linkSelectorMaxIdleTime OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Move to higher prioritized connected link
|
|
after this period of seconds of silence on the current link.
|
|
0=move immediately to higher prioritized connected link.
|
|
UNIT is seconds."
|
|
DEFVAL { 0 }
|
|
::= {linkSelectorCnfgEntry 4}
|
|
|
|
linkSelectorMode OBJECT-TYPE
|
|
SYNTAX INTEGER { notApplicable(1),
|
|
backup(2), bod(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" If the link selector is in mode:
|
|
backup(2)=then the link with the lower priority will be
|
|
used in case of failure of the higher priority link,
|
|
bod(3)=bandwidth on demand or dynamic bandwidth allocation
|
|
means that links with lower priority will be used
|
|
whenever additional bandwidth is required. "
|
|
DEFVAL { backup }
|
|
::= {linkSelectorCnfgEntry 5}
|
|
|
|
linkSelectorRevert OBJECT-TYPE
|
|
SYNTAX INTEGER { notApplicable(1),
|
|
auto(2), manual(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" If the link selector is in mode backup:
|
|
auto(2)=return automatically to Main link when it is OK.
|
|
manual(3)=stays connected to backup link."
|
|
DEFVAL { auto }
|
|
::= {linkSelectorCnfgEntry 6}
|
|
|
|
linkSelectorMinBUSession OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum duration of a backup session before
|
|
returning to Main Link. Relevant in Backup Mode and
|
|
when Revert is auto(2). Value 255 is for NEVER which
|
|
means never return to Main Link.
|
|
UNIT is minutes."
|
|
DEFVAL { 10 }
|
|
::= {linkSelectorCnfgEntry 7}
|
|
|
|
-- Prioritized Links
|
|
linkSelectorPLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LinkSelectorPLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtLogicalCnfg 3}
|
|
|
|
linkSelectorPLinkEntry OBJECT-TYPE
|
|
SYNTAX LinkSelectorPLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {pLinkCnfgIdx, pLinkSltIdx, pLinkPrtIdx, pLinkIdx }
|
|
::= { linkSelectorPLinkTable 1}
|
|
|
|
LinkSelectorPLinkEntry ::=
|
|
SEQUENCE {
|
|
pLinkCnfgIdx Integer32,
|
|
pLinkSltIdx INTEGER,
|
|
pLinkPrtIdx Integer32,
|
|
pLinkIdx Integer32,
|
|
pLinkSlotNu INTEGER,
|
|
pLinkPortNu Integer32,
|
|
pLinkPrioNu Integer32,
|
|
pLinkVRate INTEGER
|
|
}
|
|
|
|
pLinkCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { linkSelectorPLinkEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
pLinkSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot Index"
|
|
::= { linkSelectorPLinkEntry 2}
|
|
|
|
pLinkPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32(200..250)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
This port number should be the link selector number."
|
|
::= { linkSelectorPLinkEntry 3}
|
|
|
|
|
|
pLinkIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This index is the row number."
|
|
::= { linkSelectorPLinkEntry 4}
|
|
|
|
pLinkSlotNu OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noConnect (2), cl(3),
|
|
io1(5),
|
|
io2(6),
|
|
io3(7),
|
|
io4(8),
|
|
io5(9),
|
|
io6(10),
|
|
io7(11),
|
|
io8(12),
|
|
io9(13),
|
|
io10(14),
|
|
io11(15),
|
|
io12(16),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot of the prioritized link.
|
|
For ISDN BRI ports of MX300/30,
|
|
io1(5) = isdn1(5) and io2(6) = isdn2(6)."
|
|
DEFVAL { noConnect }
|
|
::= { linkSelectorPLinkEntry 5 }
|
|
|
|
pLinkPortNu OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port of the prioritized link.
|
|
Value 100 is for noConnect."
|
|
DEFVAL { 100 }
|
|
::= { linkSelectorPLinkEntry 6 }
|
|
|
|
pLinkPrioNu OBJECT-TYPE
|
|
SYNTAX Integer32(1..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The priority of the prioritized link.
|
|
MIN=1...., MAX=8."
|
|
::= { linkSelectorPLinkEntry 7 }
|
|
|
|
pLinkVRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
r1x56eq56Kbps (1),
|
|
r1x64eq64Kbps (2),
|
|
r2x56eq112Kbps (3),
|
|
r2x64eq128Kbps (4),
|
|
r3x56eq168Kbps (5),
|
|
r3x64eq192Kbps (6),
|
|
r4x56eq224Kbps (7),
|
|
r4x64eq256Kbps (8),
|
|
r5x56eq280Kbps (9),
|
|
r5x64eq320Kbps (10),
|
|
r6x56eq336Kbps (11),
|
|
r6x64eq384Kbps (12),
|
|
r7x56eq392Kbps (13),
|
|
r7x64eq448Kbps (14),
|
|
r8x56eq448Kbps (15),
|
|
r8x64eq512Kbps (16),
|
|
r9x56eq504Kbps (17),
|
|
r9x64eq576Kbps (18),
|
|
r10x56eq560Kbps (19),
|
|
r10x64eq640Kbps (20),
|
|
r11x56eq616Kbps (21),
|
|
r11x64eq704Kbps (22),
|
|
r12x56eq672Kbps (23),
|
|
r12x64eq768Kbps (24),
|
|
r13x56eq728Kbps (25),
|
|
r13x64eq832Kbps (26),
|
|
r14x56eq784Kbps (27),
|
|
r14x64eq896Kbps (28),
|
|
r15x56eq840Kbps (29),
|
|
r15x64eq960Kbps (30),
|
|
r16x56eq896Kbps (31),
|
|
r16x64eq1024Kbps(32),
|
|
r17x56eq952Kbps (33),
|
|
r17x64eq1088Kbps(34),
|
|
r18x56eq1008Kbps(35),
|
|
r18x64eq1152Kbps(36),
|
|
r19x56eq1064Kbps(37),
|
|
r19x64eq1216Kbps(38),
|
|
r20x56eq1120Kbps(39),
|
|
r20x64eq1280Kbps(40),
|
|
r21x56eq1176Kbps(41),
|
|
r21x64eq1344Kbps(42),
|
|
r22x56eq1232Kbps(43),
|
|
r22x64eq1408Kbps(44),
|
|
r23x56eq1288Kbps(45),
|
|
r23x64eq1472Kbps(46),
|
|
r24x56eq1344Kbps(47),
|
|
r24x64eq1536Kbps(48),
|
|
r25x56eq1400Kbps(49),
|
|
r25x64eq1600Kbps(50),
|
|
r26x56eq1456Kbps(51),
|
|
r26x64eq1664Kbps(52),
|
|
r27x56eq1512Kbps(53),
|
|
r27x64eq1728Kbps(54),
|
|
r28x56eq1568Kbps(55),
|
|
r28x64eq1792Kbps(56),
|
|
r29x56eq1624Kbps(57),
|
|
r29x64eq1856Kbps(58),
|
|
r30x56eq1680Kbps(59),
|
|
r30x64eq1920Kbps(60),
|
|
r31x56eq1736Kbps(61),
|
|
r31x64eq1984Kbps(62),
|
|
noRate(100)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The rate to use with this link."
|
|
DEFVAL { noRate }
|
|
::= { linkSelectorPLinkEntry 8 }
|
|
|
|
|
|
--
|
|
-- Megaplex or Kilomux ?000/?004 MPH.1/3 High speed packet data cards.
|
|
-- Megaplex or Kilomux ?000/?004 MPL.6 Low speed packet data cards.
|
|
-- (Mph1, Mph3, Mpl6)
|
|
-- Maxcess 3000/3004 MLS-3/6, MHS-1/3
|
|
--
|
|
-- prtExPhPlCnfgTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 1}
|
|
-- prtExPhPlDlciTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 2}
|
|
-- prtExPhPlModemTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 3}
|
|
|
|
-- Mph.1 Mph.3 Mpl.6/ Kphs.1 Kphs.3 Mls.3 Mls.6 Mhs.1 Mhs.3
|
|
-- External port objects table
|
|
|
|
prtExPhPlCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExPhPlCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The write operation into the Table Objects is
|
|
valid only to the TmpCnfg entry."
|
|
::= {prtPhPlCnfg 1}
|
|
|
|
prtExPhPlCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExPhPlCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExPhPlCnfgIdx, prtExPhPlSltIdx, prtExPhPlPrtIdx}
|
|
::= { prtExPhPlCnfgTable 1}
|
|
|
|
PrtExPhPlCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExPhPlCnfgIdx Integer32,
|
|
prtExPhPlSltIdx INTEGER,
|
|
prtExPhPlPrtIdx INTEGER,
|
|
prtExPhPlConnect INTEGER,
|
|
prtExPhPlHRate INTEGER,
|
|
prtExPhPlLRate INTEGER,
|
|
prtExPhPlProtocol INTEGER,
|
|
prtExPhPlConnectionTyp INTEGER,
|
|
prtExPhPlClkMode INTEGER,
|
|
prtExPhPlDceClkSrc INTEGER,
|
|
prtExPhPlCongResponse INTEGER,
|
|
prtExPhPlCongLevel Integer32,
|
|
prtExPhPlTc INTEGER,
|
|
prtExPhPlFlowControl INTEGER,
|
|
prtExPhPlDcdRts INTEGER,
|
|
prtExPhPlDcdRtsControlPath INTEGER,
|
|
prtExPhPlDataBits INTEGER,
|
|
prtExPhPlParity INTEGER,
|
|
prtExPhPlStopBits INTEGER,
|
|
prtExPhPlLXon Integer32,
|
|
prtExPhPlLXoff Integer32,
|
|
prtExPhPlFrMngProt INTEGER,
|
|
prtExPhPlEnqPeriod Integer32,
|
|
prtExPhPlFullRptPeriod Integer32,
|
|
prtExPhPlFrWindowSize Integer32,
|
|
prtExPhPlErrorsThreshold Integer32,
|
|
prtExPhPlPvcCreateMsg INTEGER,
|
|
prtExPhPlCllmMsg INTEGER,
|
|
prtExPhPlProtDelayLevel INTEGER,
|
|
prtExPhPlClockEncoding INTEGER,
|
|
prtExPhPlMinSeparators Integer32,
|
|
prtExPhPlCcittCrc INTEGER,
|
|
prtExPhPlFrameSeparator INTEGER,
|
|
prtExPhPlIdleCode Integer32,
|
|
prtExPhPlJitter Integer32
|
|
}
|
|
|
|
prtExPhPlCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtExPhPlCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExPhPlSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
|
|
::= { prtExPhPlCnfgEntry 2}
|
|
|
|
prtExPhPlPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
In case of PH.1 card, only exPrt(1) is valid."
|
|
::= { prtExPhPlCnfgEntry 3}
|
|
|
|
prtExPhPlConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be considered
|
|
in any of the mux algorithms."
|
|
::= { prtExPhPlCnfgEntry 4}
|
|
|
|
prtExPhPlHRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
r32KbpsNLE (2),
|
|
r48KbpsNLE (3),
|
|
r56KbpsNLE (4),
|
|
r64KbpsNLE (5),
|
|
r112KbpsNLE (6),
|
|
r128KbpsNLE (7),
|
|
r168KbpsNLE (8),
|
|
r192KbpsNLE (9),
|
|
r224KbpsNLE (10),
|
|
r256KbpsNLE (11),
|
|
r280KbpsE (12),
|
|
r320KbpsE (13),
|
|
r336KbpsNLE (14),
|
|
r384KbpsNLE (15),
|
|
r392KbpsE (16),
|
|
r448KbpsNLE (17),
|
|
r504KbpsLE (18), -- r504KbpsE
|
|
r512KbpsE (19), -- r512KbpsNLE
|
|
r560KbpsE (20),
|
|
r576KbpsLE (21), -- r576KbpsE
|
|
r616KbpsE (22),
|
|
r640KbpsE (23),
|
|
r672KbpsNLE (24),
|
|
r704KbpsE (25),
|
|
r728KbpsE (26),
|
|
r768KbpsNLE (27),
|
|
r784KbpsE (28),
|
|
r832KbpsE (29),
|
|
r840KbpsE (30),
|
|
r896KbpsNLE (31),
|
|
r952KbpsE (32),
|
|
r960KbpsE (33),
|
|
r1008KbpsLE (34), -- r1008KbpsE
|
|
r1024KbpsE (35), -- r1024KbpsNLE
|
|
r1064KbpsE (36),
|
|
r1088KbpsE (37),
|
|
r1120KbpsE (38),
|
|
r1152KbpsLE (39), -- r1152KbpsE
|
|
r1176KbpsE (40),
|
|
r1216KbpsE (41),
|
|
r1232KbpsE (42),
|
|
r1280KbpsE (43),
|
|
r1288KbpsE (44),
|
|
r1344KbpsNLE (45),
|
|
r1400KbpsE (46),
|
|
r1408KbpsE (47),
|
|
r1456KbpsE (48),
|
|
r1472KbpsE (49),
|
|
r1512KbpsE (50),
|
|
r1536KbpsE (51), -- r1536KbpsNLE
|
|
r1568KbpsE (52),
|
|
r1600KbpsE (53),
|
|
r1624KbpsE (54),
|
|
r1664KbpsE (55),
|
|
r1680KbpsE (56),
|
|
r1728KbpsE (57),
|
|
r1736KbpsE (58),
|
|
r1792KbpsNLE (59),
|
|
r1856KbpsE (60),
|
|
r1920KbpsE (61),
|
|
r1984KbpsE (62),
|
|
r2048KbpsE (63), -- r2048KbpsNLE
|
|
--
|
|
-- Additional rates for: MAXcess, MP2100h
|
|
--
|
|
r9d6KbpsNLE (65),
|
|
r14d4KbpsNLE (66),
|
|
r16KbpsNLE (67),
|
|
r19d2KbpsNLE (68),
|
|
r28d8KbpsNLE (69),
|
|
r38d4KbpsNLE (70),
|
|
r57d6KbpsNLE (71), -- For Mx 30/300 Only
|
|
r115d2KbpsNLE (72), -- For Mx 30/300 Only
|
|
r24000bps (73)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the port speed for HIGH speed cards.
|
|
The card has limitations about the maximum sigma channel
|
|
speeds and about the possible rates for each clock mode .
|
|
N - The rate is valid for DCE and EXT-DCE Nodal clock mode.
|
|
L - The rate is valid for DCE and EXT-DCE Local clock mode.
|
|
E - The rate is valid for DTE External clock mode.
|
|
'r9d6KbpsNLE' means rate of 9.6 Kbps ('d'=dot).
|
|
|
|
Note: Some rate attributes have been changed. As the MIB was already
|
|
released with the old attributes, the names of the options were
|
|
not changed. The new names + attributes are in a comment.
|
|
Example: r2048KbpsE (63), -- r2048KbpsNLE"
|
|
::= { prtExPhPlCnfgEntry 5}
|
|
|
|
prtExPhPlLRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
r300bpsNLE (2),
|
|
r600bpsNLE (3),
|
|
r800bpsNLE (4),
|
|
r1200bpsNLE (5),
|
|
r2400bpsNLE (6),
|
|
r4800bpsNLE (7),
|
|
r9600bpsNLE (8),
|
|
r14400bpsLE (9), -- r14400bpsNLE
|
|
r19200bpsNLE (10),
|
|
r28800bpsLE (11), -- r28800bpsNLE
|
|
r32000bpsNLE (12),
|
|
r38400bpsNLE (13),
|
|
r48000bpsNLE (14),
|
|
r56000bpsNLE (15),
|
|
r57600bpsLE (16), -- r57600bpsNLE
|
|
r64000bpsNLE (17),
|
|
r112000bps (18), -- For Mx 30/300 Only: r112000bpsNLE
|
|
r115200bps (19), -- For Mx 30/300 Only: r115200bpsNLE
|
|
--
|
|
-- additional rates
|
|
--
|
|
r16000bpsNLE (20),
|
|
r100bpsNLE (21), -- For Mx 30/300 Only
|
|
r128000bps (22), -- For Mx 30/300 Only
|
|
r24000bps (23)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the port speed for LOW speed cards.
|
|
The card has limitations about the possible rates for each
|
|
clock mode.
|
|
N - The rate is valid for DCE and EXT-DCE Nodal clock mode.
|
|
L - The rate is valid for DCE and EXT-DCE Local clock mode.
|
|
E - The rate is valid for DTE External clock mode.
|
|
|
|
Note: Some rate attributes have been changed. As the MIB was already
|
|
released with the old attributes, the names of the options were
|
|
not changed. The new names + attributes are in a comment.
|
|
Example: r57600bpsLE (16), -- r57600bpsNLE "
|
|
|
|
::= { prtExPhPlCnfgEntry 6}
|
|
|
|
prtExPhPlProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fr (1),
|
|
frPlus (2),
|
|
pCellRelay (3),
|
|
hdlcSdlc (4),
|
|
transparentHdlc (5),
|
|
async (6),
|
|
asyncReliable (7),
|
|
activePPP (8),
|
|
slip (9),
|
|
pppAgent (10),
|
|
slipAgent (11),
|
|
transparent (12),
|
|
sna (13),
|
|
ft1Dot2 (14) -- Standard IEC 870-5-1 for Frame Transport
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the applied protocol."
|
|
::= { prtExPhPlCnfgEntry 7}
|
|
|
|
prtExPhPlConnectionTyp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
sameNetManaged (1),
|
|
sameNetNotMana (2),
|
|
user (3),
|
|
otherNet (4),
|
|
pubNet (5),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the link connection type.
|
|
It is required for three reasons:
|
|
FR/CR Inband management opration (LMI,CLMM...).
|
|
CIR check.
|
|
NMS network management.
|
|
|
|
SameNetManaged - indicates network internal line.
|
|
SameNetMotMana - indicates network internal line, but the
|
|
remote mux is not managed by the NMS.
|
|
|
|
User - User to Network Interface.
|
|
OtherNet - Network To Network Interface.
|
|
PubNet - Access Mux To PubNet Interface."
|
|
::= { prtExPhPlCnfgEntry 8}
|
|
|
|
prtExPhPlClkMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dce (1),
|
|
extDce (2),
|
|
dte (3),
|
|
int (4),
|
|
lbt (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock mode."
|
|
::= { prtExPhPlCnfgEntry 9}
|
|
|
|
prtExPhPlDceClkSrc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
local (2),
|
|
nodalTiming (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the source of the clock when working
|
|
in dce or ext-dce clock mode.
|
|
notApplicable(1) - is applied for dte(3) and lbt(5) clock modes.
|
|
When clock mode is dte, the clock source is
|
|
always external, therefore this object's value is
|
|
notApplicable.
|
|
local(2) and nodalTiming(3) - are valid in dce(1), extDce(2)
|
|
or int(4) clock modes.
|
|
The recommended clock source is local(2)."
|
|
::= { prtExPhPlCnfgEntry 10}
|
|
|
|
prtExPhPlCongResponse OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
flowControl (3), -- duplex, to/from flow control
|
|
toFlowControl (4) -- simplex , only to flow control
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates how to handle the congestion indication
|
|
to/from the mux internal connection side (for example
|
|
transmit/received becn to/from the network).
|
|
no - do nothing
|
|
flowControl - translates the congestion indication between the
|
|
port and the internal connection port according
|
|
to the definition of the prtInPh1MlFlowControl
|
|
parameters. The operation is done on both
|
|
directions.
|
|
toFlowControl- translates the backward congestion indication
|
|
received from the internal connection port
|
|
(normally the network side) to flow control and
|
|
do nothing in the other direction."
|
|
::= { prtExPhPlCnfgEntry 11}
|
|
|
|
prtExPhPlCongLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (0..70)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the level of delayed data in
|
|
precents of total available dynamic memory,
|
|
for which the port will start to operate as congested.
|
|
The resolution of the parameter is 5 percent."
|
|
::= { prtExPhPlCnfgEntry 12}
|
|
|
|
prtExPhPlTc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
tc1sec (1),
|
|
tc2sec (2),
|
|
tc3sec (3),
|
|
tc4sec (4),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Tc parameter which is the time
|
|
period of the sliding window in which the Bc/Be are tested.
|
|
The value of this parameter is identical for all the ports
|
|
of a specific card ."
|
|
::= { prtExPhPlCnfgEntry 13}
|
|
|
|
prtExPhPlFlowControl OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (2),
|
|
fecnBecn (3),
|
|
xonXoff (4),
|
|
dtrCts (5),
|
|
speedReduction (6) -- simplex response only congestion to flow control
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the required flow control betweeen
|
|
the port and the remote equipment.
|
|
fecnBecn - is valid only for FR, FR+ and CR protocols.
|
|
xonXoff,dtrCts - are valid only for Async protocols.
|
|
speedReduction - is valid only for DLC protocol when the
|
|
Clock Mode is DCE and the Clock Source is
|
|
Local."
|
|
::= { prtExPhPlCnfgEntry 14}
|
|
|
|
prtExPhPlDcdRts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
on (2),
|
|
endToEnd (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Protocol may require end to end connect indication over the
|
|
network. End to end link connection establishment over the
|
|
FR network will be indicated to the user by using DCD or
|
|
RTS control signals, depending on the clock mode: DCE or
|
|
DTE respectively.
|
|
The options are :
|
|
- On :
|
|
DCD(DCE)/RTS(DTE) will be constantly ON no matter
|
|
if the End to End connection is established or not.
|
|
- End to End:
|
|
The DCD(DCE)/RTS(DTE) will be according to the status
|
|
of the End to End connection."
|
|
::= { prtExPhPlCnfgEntry 15}
|
|
|
|
prtExPhPlDcdRtsControlPath OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Protocol may require end to end connect indication over the
|
|
network. This parameter defines whether to take the user
|
|
connection status (RTS(DCE)/DCD(DTE)) and forward it to the
|
|
network side.
|
|
- on : Transmit active connection to the network regardless
|
|
the RTS/DCD control lines status.
|
|
- off: Transmit active connection to the network according
|
|
to the status of the RTS/DCD pin. "
|
|
::= { prtExPhPlCnfgEntry 16}
|
|
|
|
prtExPhPlDataBits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
dataBits7Bits (2),
|
|
dataBits8Bits (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the number of data bits in async
|
|
frame.
|
|
It is relevant only for Async protocols."
|
|
::= { prtExPhPlCnfgEntry 17}
|
|
|
|
prtExPhPlParity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
odd (2),
|
|
even (3),
|
|
none (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the parity operation mode in
|
|
async frame.
|
|
It is relevant only for Async protocols."
|
|
::= { prtExPhPlCnfgEntry 18}
|
|
|
|
prtExPhPlStopBits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
sb1Bit (2),
|
|
sb1dot5Bits (3),
|
|
sb2Bits (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the minimum number of stop bits
|
|
in the tx async frame.
|
|
It is relevant only for Async protocols."
|
|
::= { prtExPhPlCnfgEntry 19}
|
|
|
|
prtExPhPlLXon OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the character used as X-On to
|
|
notify receive enable.
|
|
This parameter is valid only for async protocols.
|
|
Valid values: 0..255.
|
|
The value 256 indicates that it's not applicable "
|
|
::= { prtExPhPlCnfgEntry 20}
|
|
|
|
prtExPhPlLXoff OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the character used as X-Off to
|
|
notify receive disable.
|
|
This parameter is valid only for async protocols.
|
|
Valid values: 0..255.
|
|
The value 256 indicates that it's not applicable "
|
|
::= { prtExPhPlCnfgEntry 21}
|
|
|
|
prtExPhPlFrMngProt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
lmi (3),
|
|
ansiT1 (4), --Annex D
|
|
annexA (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Frame-Relay management protocol.
|
|
ansiT1 = ANSI T1.617 Annex D (this is the default value).
|
|
This parameter is applicable only for FR and FR+ protocols.
|
|
When prtExPhPlConnectionTyp = sameNetManaged, this object
|
|
will be RO (internally determined). "
|
|
::= { prtExPhPlCnfgEntry 22}
|
|
|
|
prtExPhPlEnqPeriod OBJECT-TYPE
|
|
SYNTAX Integer32 (1..30)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the Status Enquiry Period, in seconds.
|
|
It determines the frequency of the Status Enquiry message
|
|
as sent by the FR user side.
|
|
At the FR network side, it determines the timeout for this
|
|
message reception.
|
|
Default = 4 seconds.
|
|
This parameter is applicable only for FR and FR+ protocols
|
|
AND
|
|
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
|
|
::= { prtExPhPlCnfgEntry 23}
|
|
|
|
prtExPhPlFullRptPeriod OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the Full Report Frequency.
|
|
It determines the number of the Status Enquiry messages
|
|
sent by the FR user side, before a Full Report Request is
|
|
sent.
|
|
The units are : Status Enquiry messages (periods).
|
|
Valid values: 1 .. 255.
|
|
255 = infinite.
|
|
This parameter is applicable only for FR and FR+ protocols
|
|
AND
|
|
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
|
|
::= { prtExPhPlCnfgEntry 24}
|
|
|
|
prtExPhPlFrWindowSize OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the FR Window Size.
|
|
It determines the number of samplings in the sliding window
|
|
that counts the errors.
|
|
This parameter is applicable only for FR and FR+ protocols
|
|
AND
|
|
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
|
|
::= { prtExPhPlCnfgEntry 25}
|
|
|
|
prtExPhPlErrorsThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the Max Errors.
|
|
It determines the number of Status Enquiry Errors that
|
|
occured within the FR sliding window, before this port is
|
|
considered DOWN (threshold).
|
|
This parameter is applicable only for FR and FR+ protocols
|
|
AND
|
|
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
|
|
::= { prtExPhPlCnfgEntry 26}
|
|
|
|
prtExPhPlPvcCreateMsg OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is Update Message (if required or not).
|
|
It determines whether a message of a New PVC Creation is
|
|
requested or not (yes/no).
|
|
Default = no.
|
|
This parameter is applicable only for FR and FR+ protocols
|
|
AND
|
|
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
|
|
::= { prtExPhPlCnfgEntry 27}
|
|
|
|
prtExPhPlCllmMsg OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is CLLM Message (if required or not).
|
|
It determines whether to send (or not) a congestion message
|
|
when the port is Rx congested.
|
|
Default = no.
|
|
This parameter is applicable only for FR and FR+ protocols
|
|
AND
|
|
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
|
|
::= { prtExPhPlCnfgEntry 28}
|
|
|
|
prtExPhPlProtDelayLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
s36Byte (2), --level 1
|
|
s150Byte (3), --level 2
|
|
s264Byte (4), --level 3
|
|
s378Byte (5), --level 4
|
|
s492Byte (6) --level 5
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"This object is the Segmentation in Bytes.
|
|
In some cases, the enumerated values will mean
|
|
other segmentation values than specified:
|
|
|
|
Product: MX-3000 MX-3000 MX-300/MX-30
|
|
Protocol: FR+ Transparent FR+
|
|
-----------------------------------------------------
|
|
level 1 50 Bytes 44 Bytes 50 Bytes
|
|
level 2 158 Bytes 155 Bytes 158 Bytes
|
|
level 3 266 Bytes 266 Bytes 266 Bytes
|
|
level 4 376 Bytes 377 Bytes 376 Bytes
|
|
level 5 484 Bytes 488 Bytes 484 Bytes
|
|
|
|
Defval=level 1 value
|
|
|
|
This parameter is applicable only for FR+ and
|
|
transparent protocols."
|
|
::= { prtExPhPlCnfgEntry 29}
|
|
|
|
prtExPhPlClockEncoding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
nrz (2),
|
|
nrzI (3),
|
|
fm0 (4),
|
|
manchester (5),
|
|
diffManchester(6),
|
|
nrzISpace (7),
|
|
nrzIMark (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the Encoding type of the Line.
|
|
This parameter is applicable only for FR and FR+ protocols.
|
|
For MAXCESS 3000 & MP2100H: when setting to nrzI (3) the nrzI works
|
|
as nrzI Mark.
|
|
For MAXCESS 30/300 when setting to nrzI (3) the nrzI works as nrzI Space."
|
|
::= { prtExPhPlCnfgEntry 30}
|
|
|
|
prtExPhPlMinSeparators OBJECT-TYPE
|
|
SYNTAX Integer32 (0..16)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum number of bytes separating between two adjacent frames (HDLC item).
|
|
0 = notApplicable"
|
|
::= { prtExPhPlCnfgEntry 31}
|
|
|
|
prtExPhPlCcittCrc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
crc16 (2),
|
|
crc32 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates how many Bits are used for CRC (HDLC item)."
|
|
::= { prtExPhPlCnfgEntry 32}
|
|
|
|
prtExPhPlFrameSeparator OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
idles (2),
|
|
flags (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates what should be transferred on the line when there
|
|
are no frames to pass (HDLC item).
|
|
idles: mean that FF will pass on the line
|
|
flags: mean that 7E will pass on the line."
|
|
::= { prtExPhPlCnfgEntry 33}
|
|
|
|
prtExPhPlIdleCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines the code for transmission when there are no frames to transmit
|
|
on the line. The value should be 0 to FFH."
|
|
::= { prtExPhPlCnfgEntry 34}
|
|
|
|
prtExPhPlJitter OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum variant delay of the FR network, in msec."
|
|
::= { prtExPhPlCnfgEntry 35}
|
|
|
|
--
|
|
-- PH.1 & PH.3
|
|
-- External port Dlci table
|
|
--
|
|
prtExPhPlDlciTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExPhPlDlciEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
at the TmpCnfg entry."
|
|
::= {prtPhPlCnfg 2}
|
|
|
|
prtExPhPlDlciEntry OBJECT-TYPE
|
|
SYNTAX PrtExPhPlDlciEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExPhPlDlciCnfgIdx, prtExPhPlDlciSltIdx, prtExPhPlDlciPrtIdx, prtExPhPlDlciIdx }
|
|
::= { prtExPhPlDlciTable 1}
|
|
|
|
PrtExPhPlDlciEntry ::=
|
|
SEQUENCE {
|
|
prtExPhPlDlciCnfgIdx Integer32,
|
|
prtExPhPlDlciSltIdx INTEGER,
|
|
prtExPhPlDlciPrtIdx INTEGER,
|
|
prtExPhPlDlciIdx Integer32,
|
|
|
|
prtExPhPlDlciValid INTEGER,
|
|
prtExPhPlDlciIConSlt INTEGER,
|
|
prtExPhPlDlciIConPrt INTEGER,
|
|
prtExPhPlDlciIConDlci Integer32,
|
|
|
|
prtExPhPlDlciTxBc INTEGER,
|
|
prtExPhPlDlciTxBe INTEGER,
|
|
prtExPhPlDlciRxBc INTEGER,
|
|
prtExPhPlDlciRxBe INTEGER,
|
|
|
|
prtExPhPlDlciPriority Integer32,
|
|
|
|
prtExPhPlDlciStatus INTEGER
|
|
}
|
|
|
|
|
|
prtExPhPlDlciCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtExPhPlDlciEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExPhPlDlciSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid"
|
|
::= { prtExPhPlDlciEntry 2}
|
|
|
|
prtExPhPlDlciPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique internal port number.
|
|
PH.1/E1 and PH.1/T1 cards have three internal ports.
|
|
Stand-alone units may have six such ports."
|
|
::= { prtExPhPlDlciEntry 3}
|
|
|
|
prtExPhPlDlciIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..991)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique index for each possible
|
|
used dlci(16..991). When the protocol is not Multiplexing
|
|
protocol, its type is 'user' and the only valid index is 1."
|
|
::= { prtExPhPlDlciEntry 4}
|
|
|
|
prtExPhPlDlciValid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the attributes in this
|
|
entry are valid or not. The user can add/delete pvc (dlci
|
|
to dlci connection) by modifing this object"
|
|
::= { prtExPhPlDlciEntry 5}
|
|
|
|
prtExPhPlDlciIConSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noConnect (2),
|
|
cl (3),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position In the Mux
|
|
(Agent) where the dlci is routed to.
|
|
cl - will represent any of the CL slots. This value can be
|
|
selected for multiple DLCIs of the product.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid"
|
|
::= { prtExPhPlDlciEntry 6}
|
|
|
|
prtExPhPlDlciIConPrt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
clNMS (99),
|
|
noConnect (100),
|
|
inPrt1 (101) ,
|
|
inPrt2 (102) ,
|
|
inPrt3 (103) ,
|
|
inPrt4 (104) ,
|
|
inPrt5 (105) ,
|
|
inPrt6 (106) ,
|
|
inPrt7 (107) ,
|
|
inPrt8 (108) ,
|
|
inPrt9 (109) ,
|
|
inPrt10 (110)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port id which the dlci is
|
|
routed to.
|
|
clNMS - will be used for NMS SNMP messages. It can be any
|
|
port of the CL card.
|
|
This value will be selectable only if
|
|
prtExPhPlDlciIConSlt='cl' or 'notApplicable'."
|
|
::= { prtExPhPlDlciEntry 7}
|
|
|
|
|
|
prtExPhPlDlciIConDlci OBJECT-TYPE
|
|
SYNTAX Integer32 (1..991)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique internal connection dlci
|
|
number, the dlci is routed to."
|
|
::= { prtExPhPlDlciEntry 8}
|
|
|
|
prtExPhPlDlciTxBc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
txBc9600bps (3),
|
|
txBc14400bps (4),
|
|
txBc19200bps (5),
|
|
txBc28800bps (6),
|
|
txBc32000bps (7),
|
|
txBc38400bps (8),
|
|
txBc48000bps (9),
|
|
txBc56000bps (10),
|
|
txBc57600bps (11),
|
|
txBc64Kbps (12),
|
|
txBc128Kbps (13),
|
|
txBc192Kbps (14),
|
|
txBc256Kbps (15),
|
|
txBc320Kbps (16),
|
|
txBc384Kbps (17),
|
|
txBc448Kbps (18),
|
|
txBc512Kbps (19),
|
|
txBc768Kbps (20),
|
|
txBc1024Kbps (21),
|
|
--
|
|
--KM30 ; KM300 additional rates
|
|
--
|
|
txBc16000bps (25),
|
|
txBc112Kbps (26)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Tx committed bandwidth on
|
|
the user transmit line (or at the port receive line)."
|
|
::= { prtExPhPlDlciEntry 9}
|
|
|
|
|
|
prtExPhPlDlciTxBe OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
txBe9600bps (3),
|
|
txBe14400bps (4),
|
|
txBe19200bps (5),
|
|
txBe28800bps (6),
|
|
txBe32000bps (7),
|
|
txBe38400bps (8),
|
|
txBe48000bps (9),
|
|
txBe56000bps (10),
|
|
txBe57600bps (11),
|
|
txBe64Kbps (12),
|
|
txBe128Kbps (13),
|
|
txBe192Kbps (14),
|
|
txBe256Kbps (15),
|
|
txBe320Kbps (16),
|
|
txBe384Kbps (17),
|
|
txBe448Kbps (18),
|
|
txBe512Kbps (19),
|
|
txBe768Kbps (20),
|
|
txBe1024Kbps (21),
|
|
--
|
|
--KM30 ; KM300 additional rates
|
|
--
|
|
txBc16000bps (25),
|
|
txBc112Kbps (26)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Tx excess bandwidth on the
|
|
user transmit line (or at the port receive line)."
|
|
::= { prtExPhPlDlciEntry 10}
|
|
|
|
|
|
prtExPhPlDlciRxBc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
rxBc9600bps (3),
|
|
rxBc14400bps (4),
|
|
rxBc19200bps (5),
|
|
rxBc28800bps (6),
|
|
rxBc32000bps (7),
|
|
rxBc38400bps (8),
|
|
rxBc48000bps (9),
|
|
rxBc56000bps (10),
|
|
rxBc57600bps (11),
|
|
rxBc64Kbps (12),
|
|
rxBc128Kbps (13),
|
|
rxBc192Kbps (14),
|
|
rxBc256Kbps (15),
|
|
rxBc320Kbps (16),
|
|
rxBc384Kbps (17),
|
|
rxBc448Kbps (18),
|
|
rxBc512Kbps (19),
|
|
rxBc768Kbps (20),
|
|
rxBc1024Kbps (21),
|
|
--
|
|
--KM30 ; KM300 additional rates
|
|
--
|
|
rxBc16000bps (25),
|
|
rxBc112Kbps (26)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Rx committed bandwidth on the
|
|
user receive line (or at the port transmit line)."
|
|
::= { prtExPhPlDlciEntry 11}
|
|
|
|
|
|
prtExPhPlDlciRxBe OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
rxBe9600bps (3),
|
|
rxBe14400bps (4),
|
|
rxBe19200bps (5),
|
|
rxBe28800bps (6),
|
|
rxBe32000bps (7),
|
|
rxBe38400bps (8),
|
|
rxBe48000bps (9),
|
|
rxBe56000bps (10),
|
|
rxBe57600bps (11),
|
|
rxBe64Kbps (12),
|
|
rxBe128Kbps (13),
|
|
rxBe192Kbps (14),
|
|
rxBe256Kbps (15),
|
|
rxBe320Kbps (16),
|
|
rxBe384Kbps (17),
|
|
rxBe448Kbps (18),
|
|
rxBe512Kbps (19),
|
|
rxBe768Kbps (20),
|
|
rxBe1024Kbps (21),
|
|
--
|
|
--KM30 ; KM300 additional rates
|
|
--
|
|
rxBc16000bps (25),
|
|
rxBc112Kbps (26)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Rx excess bandwidth on the
|
|
user receive line (or at the port transmit line)."
|
|
::= { prtExPhPlDlciEntry 12}
|
|
|
|
|
|
prtExPhPlDlciPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique priority of the pcv.
|
|
1 is the lowest priority and 8 is the highest priority."
|
|
::= { prtExPhPlDlciEntry 13}
|
|
|
|
|
|
prtExPhPlDlciStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disconnected (1),
|
|
connected (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the status of the pvc. The status is
|
|
disconnected(1) when one of the sides is programmed as not
|
|
connected"
|
|
::= { prtExPhPlDlciEntry 14}
|
|
|
|
|
|
-- Parameters of an external Modem which is connected to a High/Low Speed
|
|
-- Port.
|
|
|
|
prtExPhPlModemTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExPhPlModemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "External Modem Parameters.
|
|
The write operation into the
|
|
Table Objects is valid only for the TmpCnfg entry."
|
|
::= {prtPhPlCnfg 3}
|
|
|
|
prtExPhPlModemEntry OBJECT-TYPE
|
|
SYNTAX PrtExPhPlModemEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExPhPlModemCnfgIdx,prtExPhPlModemSltIdx,prtExPhPlModemPrtIdx}
|
|
::= { prtExPhPlModemTable 1}
|
|
|
|
PrtExPhPlModemEntry ::=
|
|
SEQUENCE {
|
|
prtExPhPlModemCnfgIdx Integer32,
|
|
prtExPhPlModemSltIdx INTEGER,
|
|
prtExPhPlModemPrtIdx INTEGER,
|
|
prtExPhPlModemStatus INTEGER,
|
|
prtExPhPlModemActivate INTEGER,
|
|
prtExPhPlModemMaxIdleTime Integer32,
|
|
prtExPhPlModemTimeBtwnCalls Integer32,
|
|
prtExPhPlModemCallDelay Integer32
|
|
}
|
|
|
|
prtExPhPlModemCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtExPhPlModemEntry 1}
|
|
|
|
prtExPhPlModemSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
|
|
::= { prtExPhPlModemEntry 2}
|
|
|
|
prtExPhPlModemPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
In case of PH.1 card, only exPrt(1) is valid."
|
|
::= { prtExPhPlModemEntry 3}
|
|
|
|
prtExPhPlModemStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disable (2),
|
|
enable (3),
|
|
relay (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether a Dial Up Modem is enabled on this port.
|
|
Default: disable
|
|
|
|
For Vmux devices this object shows whether there is Modem Relay support."
|
|
::= { prtExPhPlModemEntry 4}
|
|
|
|
prtExPhPlModemActivate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
onFirstFrame(2),
|
|
always (3),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the Dial Up Modem is activated when
|
|
the first frame is received or it is always activated.
|
|
Default: onFirstFrame"
|
|
::= { prtExPhPlModemEntry 5}
|
|
|
|
prtExPhPlModemMaxIdleTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Max Time allowed in Seconds without any traffic before the line
|
|
is disconnected.
|
|
|
|
Legal Values are: 1 sec, 2 sec .. 5 sec, 10 sec, 20 sec..
|
|
1 min, 2 min .. 10 min, 15 min, 20 min, 25 min, 30 min.
|
|
65535 sec. means that this parameter is not applicable.
|
|
|
|
Default: 1 sec."
|
|
::= { prtExPhPlModemEntry 6}
|
|
|
|
prtExPhPlModemTimeBtwnCalls OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum Time in Seconds which is required after a call was
|
|
disconnected. In this time no other call will be initiated
|
|
from this Modem port even if there were frames transmitted
|
|
to this port. This time is required for some Modems which
|
|
have initializations that take a few seconds.
|
|
|
|
Legal Values are:
|
|
0 sec. - 30 sec., 1-5 min.
|
|
65535 sec. means that this parameter is not applicable.
|
|
|
|
Default: 0 sec"
|
|
::= { prtExPhPlModemEntry 7}
|
|
|
|
prtExPhPlModemCallDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time in Seconds that the device will wait before dialing to the remote
|
|
device.
|
|
|
|
This feature is mostly used when there is a backup modem to the
|
|
main link and the main link is down. In this case it is important to prevent
|
|
the 2 devices from dialing through the backup modems to each other at the same time.
|
|
It is advised to configure one side with a small call delay and the other side
|
|
with a large call delay.
|
|
|
|
Legal Values are:
|
|
0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 .
|
|
65535 sec. means that this parameter is not applicable.
|
|
|
|
Default: 0 sec"
|
|
::= { prtExPhPlModemEntry 8}
|
|
|
|
--
|
|
-- Megaplex ?000/?004 LS-2 TDM I/O family card include:
|
|
-- Ls2-CCITT-X.50, Ls2-CCITT-X.58, Ls2-AT&T-SDM
|
|
--
|
|
--prtExLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 1}
|
|
--prtInLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 2}
|
|
|
|
prtExLs2CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExLs2CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtLs2Cnfg 1}
|
|
|
|
prtExLs2CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExLs2CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExLs2CnfgIdx, prtExLs2SltIdx, prtExLs2PrtIdx }
|
|
::= {prtExLs2CnfgTable 1}
|
|
|
|
PrtExLs2CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExLs2CnfgIdx Integer32,
|
|
prtExLs2SltIdx INTEGER,
|
|
prtExLs2PrtIdx INTEGER,
|
|
prtExLs2Connect INTEGER,
|
|
prtExLs2Rate INTEGER,
|
|
prtExLs2ClkMode INTEGER,
|
|
prtExLs2Cts INTEGER,
|
|
prtExLs2Dcd INTEGER,
|
|
prtExLs2EnvIdx Integer32
|
|
}
|
|
|
|
prtExLs2CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtExLs2CnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExLs2SltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid."
|
|
::= {prtExLs2CnfgEntry 2}
|
|
|
|
prtExLs2PrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port index.
|
|
For the Ls2/X.58 exPrt(7)..exPrt(10) are not valid."
|
|
::= {prtExLs2CnfgEntry 3}
|
|
|
|
|
|
prtExLs2Connect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= {prtExLs2CnfgEntry 4}
|
|
|
|
prtExLs2Rate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r2400bps (2),
|
|
r4800bps (3),
|
|
r9600bps (4),
|
|
r19200bps (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port rates."
|
|
::= {prtExLs2CnfgEntry 5}
|
|
|
|
prtExLs2ClkMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dce (1),
|
|
ext-dce (2),
|
|
dte (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port operation clock mode."
|
|
::= {prtExLs2CnfgEntry 6}
|
|
|
|
prtExLs2Cts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
on (2),
|
|
rts-min (3),
|
|
rts-max (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CTS."
|
|
::= {prtExLs2CnfgEntry 7}
|
|
|
|
prtExLs2Dcd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
on (2),
|
|
card-sync (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DCD."
|
|
::= {prtExLs2CnfgEntry 8}
|
|
|
|
prtExLs2EnvIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (0..24)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Envelope Index.
|
|
When prtInLs2EnvAssign=auto, the value is 0 (not applicable)."
|
|
::= {prtExLs2CnfgEntry 9}
|
|
|
|
-- Ls2 Internal composit channel parameters
|
|
--
|
|
prtInLs2CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtInLs2CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtLs2Cnfg 2}
|
|
|
|
prtInLs2CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtInLs2CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtInLs2CnfgIdx, prtInLs2SltIdx, prtInLs2PrtIdx }
|
|
::= {prtInLs2CnfgTable 1}
|
|
|
|
PrtInLs2CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtInLs2CnfgIdx Integer32,
|
|
prtInLs2SltIdx INTEGER,
|
|
prtInLs2PrtIdx INTEGER,
|
|
prtInLs2Connect INTEGER,
|
|
prtInLs2Group Integer32,
|
|
prtInLs2Member Integer32,
|
|
prtInLs2LinkTo INTEGER,
|
|
prtInLs2EnvAssign INTEGER
|
|
}
|
|
|
|
prtInLs2CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtInLs2CnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtInLs2SltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid."
|
|
::= {prtInLs2CnfgEntry 2}
|
|
|
|
prtInLs2PrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inPrt1 (101),
|
|
inPrt2 (102)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique internal port index."
|
|
::= {prtInLs2CnfgEntry 3}
|
|
|
|
prtInLs2Connect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be considered in
|
|
any of the mux algorithms. It also affects all the module
|
|
considerations because the module has only one Internal
|
|
interface which is the composite channel."
|
|
::= {prtInLs2CnfgEntry 4}
|
|
|
|
prtInLs2Group OBJECT-TYPE
|
|
SYNTAX Integer32 (1..12)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the group number of the port.
|
|
LS-2 internal ports with the same group number share the same Time slot of the main
|
|
link"
|
|
::= {prtInLs2CnfgEntry 5}
|
|
|
|
prtInLs2Member OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the group member id of the port.
|
|
This parameter is for the automatic envelope assignment
|
|
algorithm."
|
|
::= {prtInLs2CnfgEntry 6}
|
|
|
|
prtInLs2LinkTo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"It indicates the slot of the main link card to which the
|
|
LS2 card is mapped.
|
|
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
|
|
and prtGenCnfgLinkToPort."
|
|
::= {prtInLs2CnfgEntry 7}
|
|
|
|
prtInLs2EnvAssign OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
auto (2),
|
|
manual (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Envelope assignment type."
|
|
::= {prtInLs2CnfgEntry 8}
|
|
|
|
|
|
--
|
|
-- Megaplex?000/?004 VC-2, VC-6, VC-2/R2, VC-Q TDM I/O family port.
|
|
-- (Vc2E&m,Vc2Fxs1Plar,Vc2Fxo1,Vc2Fxs2,Vc2Fxo2,Vc2Fxs3,Vc2Fxo3)
|
|
-- Vc6E&M, Vc6Fxo, Vc6Fxs, Vc6aE&M, Vc6aFxo, Vc6aFxs
|
|
-- Vc2/R2(Fxs)
|
|
-- VC-Q
|
|
-- VC-12, VC-12/6
|
|
-- VC-8, VC-16
|
|
|
|
prtVc2CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtVc2CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"- For products supporting more than one configuration, the write operation
|
|
into the Table is valid only to the TmpCnfg entry.
|
|
- For products that do not support configurations, the write operation
|
|
into the Table will be to prtVc2CnfgIdx=1."
|
|
::= { cnfgPrtMux 5}
|
|
|
|
prtVc2CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtVc2CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtVc2CnfgIdx, prtVc2SltIdx, prtVc2PrtIdx }
|
|
::= { prtVc2CnfgTable 1}
|
|
|
|
PrtVc2CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtVc2CnfgIdx Integer32,
|
|
prtVc2SltIdx INTEGER,
|
|
prtVc2PrtIdx Integer32,
|
|
|
|
prtExVc2Connect INTEGER,
|
|
prtExVc2TransGain Integer32,
|
|
prtExVc2ReceiveGain Integer32,
|
|
prtExVc2Wire INTEGER,
|
|
prtExVc2CodingLaw INTEGER,
|
|
prtExVc2Sig INTEGER,
|
|
prtExVc2Oos INTEGER,
|
|
prtExVc2LinkTo INTEGER,
|
|
prtExVc2OperMode INTEGER,
|
|
prtExVc2SigProfile INTEGER,
|
|
prtExVc2CallEnable INTEGER,
|
|
prtExVc2R2Delay INTEGER,
|
|
prtExVc2CasStd INTEGER,
|
|
prtExVc2EchoCanceler INTEGER,
|
|
prtExVc2IfType INTEGER,
|
|
prtExVc2Encoding INTEGER,
|
|
prtExVc2TxBitCode OCTET STRING,
|
|
prtExVc2RxBitOutput OCTET STRING,
|
|
prtExVc2MeterRate INTEGER,
|
|
prtExVc2IfSignaling INTEGER,
|
|
prtExVc2SeizeAck INTEGER,
|
|
prtExVc2EandMType INTEGER,
|
|
prtExVc2RemType INTEGER,
|
|
prtExVc2ConvTime INTEGER,
|
|
prtExVc2SigFeedback INTEGER,
|
|
prtExVc2EchoCancelerModule INTEGER,
|
|
prtExVc2ReversePolarity INTEGER,
|
|
prtExVc2RingerFrequency INTEGER,
|
|
prtExVc2SigService INTEGER,
|
|
prtExVc2CallerIdEnable INTEGER,
|
|
prtExVc2CompressMethod INTEGER,
|
|
prtExVc2ObMode INTEGER,
|
|
prtExVc2VAD INTEGER,
|
|
prtExVc2NoiseLevelForVAD INTEGER,
|
|
prtExVc2WesternSigMode INTEGER,
|
|
prtExVc2BusProtectionPoint INTEGER, --not used
|
|
prtExVc2ImpedanceStandard INTEGER
|
|
}
|
|
|
|
prtVc2CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtVc2CnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtVc2SltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
For Stand Alone products like WR: notApplicable (255)"
|
|
::= {prtVc2CnfgEntry 2}
|
|
|
|
prtVc2PrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of the port, within the card.
|
|
For MP-2100/2200 card ports, Web Ranger and FCD-IP Voice ports
|
|
the values will be:
|
|
exPrt1 (1)
|
|
exPrt2 (2)
|
|
exPrt3 (3)
|
|
exPrt4 (4)
|
|
exPrt5 (5)
|
|
exPrt6 (6)
|
|
exPrt7 (7)
|
|
exPrt8 (8)
|
|
exPrt9 (9)
|
|
exPrt10 (10)
|
|
exPrt11 (11)
|
|
exPrt12 (12)
|
|
exPrt13 (13)
|
|
exPrt14 (14)
|
|
exPrt15 (15)
|
|
exPrt16 (16)
|
|
|
|
For LA-240:
|
|
The index for fixed voice ports will be -
|
|
exPrt6 (6)
|
|
exPrt7 (7)
|
|
exPrt8 (8)
|
|
exPrt9 (9)
|
|
The index for voice card ports will be -
|
|
Slot number * 100 + ch (for IO-1: 101..104, for IO-2: 201..204).
|
|
For other products' index see their specification."
|
|
::= {prtVc2CnfgEntry 3}
|
|
|
|
prtExVc2Connect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3),
|
|
v51 (4),
|
|
v52 (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= {prtVc2CnfgEntry 4}
|
|
|
|
prtExVc2TransGain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmit gain in dBm.
|
|
For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8
|
|
VC-4/Omni and VC-16 cards, the units will be 0.1dBm because
|
|
valid values can be in 0.5dBm steps."
|
|
::= {prtVc2CnfgEntry 5}
|
|
|
|
prtExVc2ReceiveGain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receive gain in dBm.
|
|
For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8
|
|
VC-4/Omni and VC-16 cards, the units will be 0.1dBm because
|
|
valid values can be in 0.5dBm steps."
|
|
::= {prtVc2CnfgEntry 6}
|
|
|
|
prtExVc2Wire OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
w2wire (1),
|
|
w4wire (2),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For some cards, this object is equal for all the ports in the specific
|
|
card because of HW limitations.
|
|
For FXO & FXS this parameter is not applicable."
|
|
::= {prtVc2CnfgEntry 7}
|
|
|
|
prtExVc2CodingLaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
aLAW (1),
|
|
uLAW (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Method/Law for decoding/encoding the voice
|
|
information.
|
|
aLaw(1) is the standard Law for E1 links.
|
|
uLaw(2) is the standard Law for T1 links.
|
|
|
|
This object is equal for all the ports in the specific module because
|
|
of HW limitations"
|
|
::= {prtVc2CnfgEntry 8}
|
|
|
|
prtExVc2Sig OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noSignaling (1),
|
|
robbedBitMultiFrame (2),
|
|
chAssociatedE1 (3),
|
|
robbedBitFrame (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the method for decoding/encoding the signaling
|
|
information(on/off hook).
|
|
noSignaling (1) - not using signaling (only voice).
|
|
robbedBitMultiFrame(2) - is the standard method for T1 links and
|
|
proprietary method for E1 links.
|
|
chAssociatedE1 (3) - is valid only for E1 G.732S links.
|
|
robbedBitFrame (4) - is proprietary method implimenting 7 bit for
|
|
the voice and 1 bit dedicated for signaling.
|
|
|
|
For some cards, this object is equal for all the ports in the specific module
|
|
because of HW limitations."
|
|
::= {prtVc2CnfgEntry 9}
|
|
|
|
prtExVc2Oos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
forcedIdle (1),
|
|
forcedBusy (2),
|
|
busyIdle (3),
|
|
idleBusy (4),
|
|
notApplicable (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is equal for all the ports in the specific card
|
|
because of HW limitations"
|
|
::= {prtVc2CnfgEntry 10}
|
|
|
|
prtExVc2LinkTo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This attribute indicates the slot of the ML card to which
|
|
the VC card is mapped.
|
|
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
|
|
and prtGenCnfgLinkToPort."
|
|
::= {prtVc2CnfgEntry 11}
|
|
|
|
prtExVc2OperMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal (2),
|
|
unidirectRx (3),
|
|
broadcast (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the operation mode of the port.
|
|
normal = bi-directional (Tx/Rx)
|
|
unidirectRx = unidirectional Rx.
|
|
broadcast = Tx upon request."
|
|
::= {prtVc2CnfgEntry 12}
|
|
|
|
|
|
prtExVc2SigProfile OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
manual (2),
|
|
p1 (3),
|
|
p2 (4),
|
|
p3Fxo3S3 (5),
|
|
reversePolarity (6), --3RP
|
|
meteringPulse (7), --3MP
|
|
p4 (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Signaling Profile of the port.
|
|
notApplicable - for VC-2 family and when
|
|
prtExVc2Sig=noSignaling(1)
|
|
p1 = profile 1
|
|
p2 = profile 2
|
|
p3 = profile 3
|
|
p4 = profile 4 "
|
|
::= {prtVc2CnfgEntry 13}
|
|
|
|
prtExVc2CallEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
incoming (2),
|
|
outgoing (3),
|
|
both (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Enabled Call direction.
|
|
notApplicable - for all cards except VC-2/R2.
|
|
both - incoming + outgoing."
|
|
::= {prtVc2CnfgEntry 14}
|
|
|
|
prtExVc2R2Delay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
terrestrial (2),
|
|
satellite (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the R2 Delay.
|
|
notApplicable - for all cards except VC-2/R2."
|
|
::= {prtVc2CnfgEntry 15}
|
|
|
|
prtExVc2CasStd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
r2Q422 (2),
|
|
specialA (3),
|
|
specialB (4),
|
|
specialC (5),
|
|
specialD (6),
|
|
specialE (7),
|
|
specialF (8),
|
|
specialG (9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the CAS (Channel Associated Signaling)
|
|
Standard.
|
|
notApplicable - for all cards except VC-2/R2."
|
|
::= {prtVc2CnfgEntry 16}
|
|
|
|
prtExVc2EchoCanceler OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Echo canceler activation.
|
|
notApplicable - for VC-2 and VC-6 cards."
|
|
::= {prtVc2CnfgEntry 17}
|
|
|
|
prtExVc2IfType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
w2Em (2),
|
|
w4Em (3),
|
|
fxo (4),
|
|
fxs (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface Type."
|
|
::= {prtVc2CnfgEntry 18}
|
|
|
|
prtExVc2Encoding OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
pcm (2),
|
|
adpcm (3),
|
|
linear (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voice Encoding Mode.
|
|
linear - is relevant only for the ports of VC-16A card."
|
|
::= {prtVc2CnfgEntry 19}
|
|
|
|
prtExVc2TxBitCode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
- - - For MP & FCD - - -
|
|
|
|
This object represents 4 parameters, by 2 Octets :
|
|
Tx D Bit Code-MSB nibble,
|
|
Tx C Bit Code- nibble,
|
|
Tx B Bit Code- nibble,
|
|
Tx A Bit Code-LSB nibble.
|
|
|
|
Each nibble:
|
|
0 hex = 0000 = Not Applicable
|
|
1 hex = 0001 = M lead
|
|
2 hex = 0010 = M lead inverse
|
|
3 hex = 0011 = Reverse Polarity
|
|
4 hex = 0100 = Metering Pulse
|
|
5 hex = 0101 = Forced 1
|
|
6 hex = 0110 = Forced 0
|
|
7-F hex - not used (invalid values)
|
|
This object will be RO if prtExVc2SigProfile is NOT manual.
|
|
|
|
|
|
- - - For WR II - - -
|
|
|
|
This object represents the following 4 parameters by 2 Octets:
|
|
1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1).
|
|
2. Default signaling bits that are not in use (nibble 2).
|
|
3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3).
|
|
4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4).
|
|
|
|
Each nibble:
|
|
---------------------------------------------------------------------------------------
|
|
Value On/Off Hook Default sig. Ring Detect. M (Mouth)
|
|
---------------------------------------------------------------------------------------
|
|
0 hex = 0000 Not Applicable Not Applicable. Not Applicable Not Applicable
|
|
1 hex = 0001 Tx A bit Values 1-3 are Tx A bit Tx A bit
|
|
2 hex = 0010 Tx A bit inverse for On/Off Hook Tx A bit inv. Tx A bit inv.
|
|
3 hex = 0011 Tx B bit A,B,A Inv,B Inv. Tx B bit Tx B bit
|
|
4 hex = 0100 Tx B bit inverse Values 4-7 are Tx B bit inv. Tx B bit inv.
|
|
5 hex = 0101 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid
|
|
6 hex = 0110 not Used-invalid A, A Inverse. not Used-invalid not Used-invalid
|
|
7 hex = 0111 not Used-invalid not Used-invalid not Used-invalid
|
|
8 hex = 1000 not Used-invalid Values 8-11 are not Used-invalid not Used-invalid
|
|
9 hex = 1001 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid
|
|
A hex = 1010 not used-invalid B, B Inverse. not Used-invalid not Used-invalid
|
|
B hex = 1011 not used-invalid The Bits order: not Used-invalid not Used-invalid
|
|
C-F hex not used-invalid ABCD not Used-invalid not Used-invalid
|
|
|
|
|
|
Default value: 11 11 "
|
|
::= {prtVc2CnfgEntry 20}
|
|
|
|
prtExVc2RxBitOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
- - - For MP (VC-Q card only) & FCD - - -
|
|
This object represents 3 parameters by 2 Octets:
|
|
Spare -MSB nibble, always=0 hex
|
|
E Lead Output - nibble,
|
|
Reverse Polarity Output- nibble,
|
|
Metering Pulse Output -LSB nibble.
|
|
|
|
Each nibble:
|
|
0 hex = 0000 = Not Applicable
|
|
1 hex = 0001 = Rx A bit
|
|
2 hex = 0010 = Rx A bit inverse
|
|
3 hex = 0011 = Rx B bit
|
|
4 hex = 0100 = Rx B bit inverse
|
|
5 hex = 0101 = Rx C bit
|
|
6 hex = 0110 = Rx C bit inverse
|
|
7 hex = 0111 = Rx D bit
|
|
8 hex = 1000 = Rx D bit inverse
|
|
9 hex = 1001 = none
|
|
A-F hex - not used (invalid values)
|
|
This object will be RO if prtExVc2SigProfile is NOT manual.
|
|
|
|
- - - For MP (VC-8, VC-16, VC-16A cards) - - -
|
|
|
|
This object represents 4 parameters, by 2 Octets :
|
|
Tx D Bit Code-MSB nibble,
|
|
Tx C Bit Code- nibble,
|
|
Tx B Bit Code- nibble,
|
|
Tx A Bit Code-LSB nibble.
|
|
|
|
Each nibble:
|
|
0 hex = 0000 = Not Applicable
|
|
1 hex = 0001 = not used (invalid value)
|
|
2 hex = 0010 = not used (invalid value)
|
|
3 hex = 0011 = not used (invalid value)
|
|
4 hex = 0100 = not used (invalid value)
|
|
5 hex = 0101 = Forced 1
|
|
6 hex = 0110 = Forced 0
|
|
7-F hex - not used (invalid values)
|
|
This object will be RO.
|
|
|
|
|
|
- - - For WR II - - -
|
|
|
|
This object represents the following 2 parameters in 1 Octet:
|
|
1. On/Off hook signaling receive mode from the T1/E1 into the FXS/FXO (MSB nibble 1).
|
|
2. E (Ear) Signaling receive mode from the T1/E1 into the E&M (LSB nibble 2).
|
|
|
|
Each nibble:
|
|
---------------------------------------------------------------------------------------
|
|
Value On/Off Hook E (Ear)
|
|
---------------------------------------------------------------------------------------
|
|
0 hex = 0000 Not Applicable Not Applicable
|
|
1 hex = 0001 Rx A bit Rx A bit
|
|
2 hex = 0010 Rx A bit inverse Rx A bit inverse
|
|
3 hex = 0011 Rx B bit Rx B bit
|
|
4 hex = 0100 Rx B bit inverse Rx B bit inverse
|
|
5-F hex not used-invalid not Used-invalid
|
|
|
|
Default value: 11 "
|
|
::= {prtVc2CnfgEntry 21}
|
|
|
|
prtExVc2MeterRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
r16Khz (2),
|
|
r12Khz (3),
|
|
disabled(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry is applicable only for VC-6A/FXO, VC-6A/FXS, VC-8/FXO,
|
|
VC-8/FXS, VC-16/FXO and VC-16/FXS.
|
|
Meter Rate means rate of Call Meter in Public Phones, in KHz units.
|
|
For some cards, the value must be the same for all card's ports."
|
|
::= {prtVc2CnfgEntry 22}
|
|
|
|
prtExVc2IfSignaling OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
loopStart (2),
|
|
groundStart (3),
|
|
winkStart (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry is applicable only for VC-6A, VC-6AG, VC-8/FXO, VC-8/FXS,
|
|
VC-16/FXO and VC-16/FXS cards.
|
|
Interface Analog Signaling.
|
|
Must be the same for all card's ports.
|
|
loopStart - for the usual trunk/phone types.
|
|
groundStart - for trunks that need Ground signaling .
|
|
winkStart - for trunks that need Reverse Polarity. "
|
|
::= {prtVc2CnfgEntry 23}
|
|
|
|
prtExVc2SeizeAck OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter shows whether the device will acknowledge
|
|
a seize signal (On/Off Hook).
|
|
When the value is set to yes(3) & the device receives an on/off hook signal
|
|
it will transmit back an on/off hook signal.
|
|
When the value is set to no(2) & the device receives an on/off hook signal
|
|
it will NOT transmit back an on/off hook signal.
|
|
|
|
Default value for WR FXO: no(2)."
|
|
::= {prtVc2CnfgEntry 24}
|
|
|
|
prtExVc2EandMType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
type1 (2),
|
|
type2 (3),
|
|
type3 (4),
|
|
type5 (5) -- SSDC5
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the signaling type on the E&M analog side.
|
|
The analog signaling includes voltage, no. of pins and other parameters."
|
|
::= {prtVc2CnfgEntry 25}
|
|
|
|
prtExVc2RemType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
lb (2),
|
|
pbx (3),
|
|
e1 (4),
|
|
t1 (5), --T1ESF
|
|
t1D4 (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote Type.
|
|
Applicable for VC-6A/4LB card &
|
|
for IPMUX-1E Far End Type - E1,T1(T1-ESF) or T1-D4 ."
|
|
::= {prtVc2CnfgEntry 26}
|
|
|
|
prtExVc2ConvTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
m2 (2),
|
|
m3 (3),
|
|
m5 (4),
|
|
unlimited (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Conversation Time in minutes.
|
|
Applicable for VC-6A/4LB card."
|
|
::= {prtVc2CnfgEntry 27}
|
|
|
|
prtExVc2SigFeedback OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signaling Feedback.
|
|
Applicable for VC-8/FXO and VC-16/FXO cards."
|
|
::= {prtVc2CnfgEntry 28}
|
|
|
|
prtExVc2EchoCancelerModule OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
notExist (2),
|
|
exist (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates whether Echo canceler module exists for this port."
|
|
::= {prtVc2CnfgEntry 29}
|
|
|
|
prtExVc2ReversePolarity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object Enables/Disables Reverse Polarity for this port."
|
|
::= {prtVc2CnfgEntry 30}
|
|
|
|
prtExVc2RingerFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
f20Hz (2),
|
|
f25Hz (3),
|
|
f50Hz (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object selects the Ringer Frequency (Hz) for this port."
|
|
::= {prtVc2CnfgEntry 31}
|
|
|
|
prtExVc2SigService OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
normal (2),
|
|
advanced (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signaling Service.
|
|
advanced - is relevant only for ports of VC-8, VC-16 FXS cards.
|
|
It is used for Signaling Services of V5.1 or R2."
|
|
::= {prtVc2CnfgEntry 32}
|
|
|
|
prtExVc2CallerIdEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object Enables/Disables Receiving the Caller Id number from the
|
|
remote side, for this port/channel."
|
|
::= {prtVc2CnfgEntry 33}
|
|
|
|
prtExVc2CompressMethod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
g726 (2),
|
|
g727 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only when prtExVc2Encoding=adpcm.
|
|
It defines which method is used for Compression.
|
|
g726 - for 4 bits (the standard method).
|
|
g726 - for 3 bits. It is especially needed for T1 applications with signaling."
|
|
::= {prtVc2CnfgEntry 34}
|
|
|
|
prtExVc2ObMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
pointToPoint (1),
|
|
omniBus (2),
|
|
pointToMultiPointSrc(3),
|
|
pointToMultiPointDst(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the Net operation mode of the Omni-Bus card's port.
|
|
pointToPoint - only 2 end-point ports talk; like any other voice card
|
|
omniBus - many talk and listen. Like conference call.
|
|
All can listen to all.
|
|
pointToMultiPointSrc - There is one Master who can be heard by all.
|
|
All can talk, but only the Master can hear all. Others can hear
|
|
only the Master. This port is of the Master (Src).
|
|
pointToMultiPointDst - There is one Master who can be heard by all.
|
|
All can talk, but only the Master can hear all. Others can hear
|
|
only the Master. This port is of a Destination (NOT Master)."
|
|
::= {prtVc2CnfgEntry 35}
|
|
|
|
prtExVc2VAD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines whether Voice Activation Detector (VAD)
|
|
will be On or Off.
|
|
off - will be usually selected when a Modem is connected
|
|
to the port; not a phone.
|
|
notApplicable - when prtExVc2DspMode=pointToPoint."
|
|
::= {prtVc2CnfgEntry 36}
|
|
|
|
prtExVc2NoiseLevelForVAD OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
low (2),
|
|
medium (3),
|
|
high (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the Level of Noise on the line,
|
|
the Voice Activation Detector (VAD) will have to deal with.
|
|
notApplicable - when prtExVc2VAD=off."
|
|
::= {prtVc2CnfgEntry 37}
|
|
|
|
prtExVc2WesternSigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
detector (2),
|
|
generator (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the Western Signaling Mode.
|
|
detector - detects signal and passes it as is.
|
|
generator - generates the signal.
|
|
notApplicable - when Western HW is not installed."
|
|
::= {prtVc2CnfgEntry 38}
|
|
|
|
prtExVc2BusProtectionPoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
no (2),
|
|
first (3),
|
|
last (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines if the port is Bus Protection Point or not.
|
|
notApplicable - when prtExVc2DspMode=pointToPoint.
|
|
When we have a chain of devices where the edge devices ports are the
|
|
Bus Protection Point, user must configure one of these ports as 'first'
|
|
and the other as 'last'. It does not matter which one, it just matters
|
|
that they will be different."
|
|
::= {prtVc2CnfgEntry 39}
|
|
|
|
prtExVc2ImpedanceStandard OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
g712 (1),
|
|
q552ETSI (2),
|
|
q522Italy(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the Standard used for Impedance.
|
|
-G.712 - 600 Ohm - used in USA and other countries.
|
|
-Q552/ETSI - used in some countries in Europe
|
|
-Q522/Italy - used in Italy."
|
|
::= {prtVc2CnfgEntry 40}
|
|
|
|
|
|
--
|
|
-- Megaplex?000/?004 port specific config for HS(TDM) modules
|
|
-- HS-2,HS-3,HS-Q, HS-Q/SC, HS-6, HS-12
|
|
--
|
|
prtHsfCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtHsfCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { cnfgPrtMux 6}
|
|
|
|
prtHsfCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtHsfCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtHsfCnfgIdx, prtHsfSltIdx, prtHsfPrtIdx }
|
|
::= { prtHsfCnfgTable 1}
|
|
|
|
PrtHsfCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtHsfCnfgIdx Integer32,
|
|
prtHsfSltIdx INTEGER,
|
|
prtHsfPrtIdx INTEGER,
|
|
prtExHsfConnect INTEGER,
|
|
prtExHsfRate INTEGER,
|
|
prtExHsfClkMode INTEGER,
|
|
prtExHsfCts INTEGER,
|
|
prtExHsfFifoSize INTEGER,
|
|
prtExHsfLinkTo INTEGER,
|
|
prtExHsfOperMode INTEGER,
|
|
prtExHsfInbandLoopback INTEGER,
|
|
prtExHsfClkPolarity INTEGER,
|
|
prtExHsfControlSignal INTEGER,
|
|
prtExHsfBcastRingSrcPort INTEGER
|
|
}
|
|
|
|
prtHsfCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relate to the TmpCnfg. "
|
|
::= {prtHsfCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtHsfSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid."
|
|
::= {prtHsfCnfgEntry 2}
|
|
|
|
prtHsfPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
exPrt11 (11) ,
|
|
exPrt12 (12) ,
|
|
inPrt1 (101) ,
|
|
inPrt2 (102)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique external port index.
|
|
Hs2 has only two ports (exPrt1,exPrt2).
|
|
Hs3 has three ports (exPrt1,exPrt2,exPrt3).
|
|
Hsq and hsqN has four ports.
|
|
Hs6 has six external ports.
|
|
Hs12 has twelve external ports.
|
|
inPrt1, inPrt2 - are relevant for VID card."
|
|
::= {prtHsfCnfgEntry 3}
|
|
|
|
prtExHsfConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= {prtHsfCnfgEntry 4}
|
|
|
|
prtExHsfRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r1x56eq56Kbps (1),
|
|
r1x64eq64Kbps (2),
|
|
r2x56eq112Kbps (3),
|
|
r2x64eq128Kbps (4),
|
|
r3x56eq168Kbps (5),
|
|
r3x64eq192Kbps (6),
|
|
r4x56eq224Kbps (7),
|
|
r4x64eq256Kbps (8),
|
|
r5x56eq280Kbps (9),
|
|
r5x64eq320Kbps (10),
|
|
r6x56eq336Kbps (11),
|
|
r6x64eq384Kbps (12),
|
|
r7x56eq392Kbps (13),
|
|
r7x64eq448Kbps (14),
|
|
r8x56eq448Kbps (15),
|
|
r8x64eq512Kbps (16),
|
|
r9x56eq504Kbps (17),
|
|
r9x64eq576Kbps (18),
|
|
r10x56eq560Kbps (19),
|
|
r10x64eq640Kbps (20),
|
|
r11x56eq616Kbps (21),
|
|
r11x64eq704Kbps (22),
|
|
r12x56eq672Kbps (23),
|
|
r12x64eq768Kbps (24),
|
|
r13x56eq728Kbps (25),
|
|
r13x64eq832Kbps (26),
|
|
r14x56eq784Kbps (27),
|
|
r14x64eq896Kbps (28),
|
|
r15x56eq840Kbps (29),
|
|
r15x64eq960Kbps (30),
|
|
r16x56eq896Kbps (31),
|
|
r16x64eq1024Kbps(32),
|
|
r17x56eq952Kbps (33),
|
|
r17x64eq1088Kbps(34),
|
|
r18x56eq1008Kbps(35),
|
|
r18x64eq1152Kbps(36),
|
|
r19x56eq1064Kbps(37),
|
|
r19x64eq1216Kbps(38),
|
|
r20x56eq1120Kbps(39),
|
|
r20x64eq1280Kbps(40),
|
|
r21x56eq1176Kbps(41),
|
|
r21x64eq1344Kbps(42),
|
|
r22x56eq1232Kbps(43),
|
|
r22x64eq1408Kbps(44),
|
|
r23x56eq1288Kbps(45),
|
|
r23x64eq1472Kbps(46),
|
|
r24x56eq1344Kbps(47),
|
|
r24x64eq1536Kbps(48),
|
|
r25x56eq1400Kbps(49),
|
|
r25x64eq1600Kbps(50),
|
|
r26x56eq1456Kbps(51),
|
|
r26x64eq1664Kbps(52),
|
|
r27x56eq1512Kbps(53),
|
|
r27x64eq1728Kbps(54),
|
|
r28x56eq1568Kbps(55),
|
|
r28x64eq1792Kbps(56),
|
|
r29x56eq1624Kbps(57),
|
|
r29x64eq1856Kbps(58),
|
|
r30x56eq1680Kbps(59),
|
|
r30x64eq1920Kbps(60),
|
|
r31x56eq1736Kbps(61),
|
|
r31x64eq1984Kbps(62),
|
|
r32Kbps (63)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the port speed. "
|
|
::= {prtHsfCnfgEntry 5}
|
|
|
|
prtExHsfClkMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dce (1),
|
|
ext-dce (2),
|
|
dte (3),
|
|
none (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port operation clock mode."
|
|
::= { prtHsfCnfgEntry 6}
|
|
|
|
prtExHsfCts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
on (2),
|
|
rts (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique CTS control line
|
|
operation mode."
|
|
::= {prtHsfCnfgEntry 7}
|
|
|
|
prtExHsfFifoSize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
auto (2),
|
|
s16bits (3),
|
|
s30bits (4),
|
|
s52bits (5),
|
|
s72bits (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Size in bits."
|
|
::= {prtHsfCnfgEntry 8}
|
|
|
|
prtExHsfLinkTo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This attribute indicates a slot of Main Link module, that the
|
|
port is linked to. This object is the same for all the
|
|
ports in the specific card because of HW limitations.
|
|
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
|
|
and prtGenCnfgLinkToPort."
|
|
::= {prtHsfCnfgEntry 9}
|
|
|
|
prtExHsfOperMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal (2),
|
|
unidirectRx (3),
|
|
broadcast (4),
|
|
bidirBcastRing (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the operation mode of the port.
|
|
normal = bi-directional (Tx/Rx)
|
|
unidirectRx = unidirectional Rx.
|
|
broadcast = Tx upon request.
|
|
bidirBcastRing = Bidirectional Broadcast Ring. When this value is selected,
|
|
AND RTS=On, the port opens its transmission channel."
|
|
::= {prtHsfCnfgEntry 10}
|
|
|
|
prtExHsfInbandLoopback OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disabled (2),
|
|
ft1Enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if Inband Loopback from the Network
|
|
should be enabled or disabled."
|
|
::= {prtHsfCnfgEntry 11}
|
|
|
|
prtExHsfClkPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
normal (2),
|
|
invert (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the clock polarity.
|
|
For FCD-M this object will be applicable only for the fixed HS port
|
|
(the fixed port on the device)."
|
|
::= {prtHsfCnfgEntry 12}
|
|
|
|
prtExHsfControlSignal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
local (2),
|
|
endToEnd (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Control Signal according to G.797 ITU-T standard.
|
|
For FCD-M this object will be applicable for the fixed HS port
|
|
(the fixed port on the device) and HS-Q/N channels.
|
|
Local and End to End are applicable only when channel Interface type is RS-530,
|
|
else it will be Not Applicable."
|
|
::= {prtHsfCnfgEntry 13}
|
|
|
|
prtExHsfBcastRingSrcPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
exPrt11 (11) ,
|
|
exPrt12 (12) ,
|
|
none (100) ,
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only when prtExHsfOperMode=
|
|
bidirBcastRing. In this case, the values mean:
|
|
- none - this port will be connected to ML in TSA as usual.
|
|
- exPrt1.. exPrtX ; X=maximum ports of the card in focus :
|
|
it means that the same TS that is assigned in TSA to this port
|
|
is actually connected also to this port, for Broadcast Ring mode.
|
|
Therefore, this port should NOT be connected to ML in TSA."
|
|
::= {prtHsfCnfgEntry 14}
|
|
|
|
--
|
|
-- Megaplex?000/?004 Hs-4/1(HS4T1) HS-4/2(HS4E1) port configuration
|
|
--
|
|
--prtExHs4CnfgTable OBJECT IDENTIFIER ::= {prtHs4Cnfg 1}
|
|
--prtExHs4TsCnfgTable OBJECT IDENTIFIER ::= {prtHs4Cnfg 2}
|
|
|
|
prtExHs4CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExHs4CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtHs4Cnfg 1}
|
|
|
|
prtExHs4CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExHs4CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExHs4CnfgIdx, prtExHs4SltIdx, prtExHs4PrtIdx }
|
|
::= { prtExHs4CnfgTable 1}
|
|
|
|
PrtExHs4CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExHs4CnfgIdx Integer32,
|
|
prtExHs4SltIdx INTEGER,
|
|
prtExHs4PrtIdx INTEGER,
|
|
|
|
prtExHs4Connect INTEGER,
|
|
prtExHs4LineType INTEGER,
|
|
prtExHs4LineCode INTEGER,
|
|
prtExHs4LineLen INTEGER,
|
|
prtExHs4RestoreT INTEGER,
|
|
prtExHs4OosSig INTEGER,
|
|
prtExHs4OosCode INTEGER,
|
|
prtExHs4IdleCode Integer32,
|
|
prtExHs4MfClkSrcSlt INTEGER,
|
|
prtExHs4MfClkSrcPrt INTEGER
|
|
}
|
|
|
|
prtExHs4CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtExHs4CnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExHs4SltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted."
|
|
::= {prtExHs4CnfgEntry 2}
|
|
|
|
prtExHs4PrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of the port, within the card."
|
|
::= {prtExHs4CnfgEntry 3}
|
|
|
|
prtExHs4Connect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
considered in any of the mux algorithm. It also affects
|
|
all the module considerations because the card has only
|
|
one external (physical) interface."
|
|
::= {prtExHs4CnfgEntry 4}
|
|
|
|
prtExHs4LineType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
esfT1 (2), --> dsx1ESF
|
|
sfT1 (3), --> dsx1D4
|
|
g732nE1 (4), --> dsx1E1
|
|
g732nE1CRC (5), --> dsx1E1-CRC
|
|
g732sE1 (6), --> dsx1E1-MF
|
|
g732sE1CRC (7) --> dsx1E1-MF-CRC
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the line type parameter for T1/E1
|
|
interface.
|
|
The user should select only the parameters relevant to the
|
|
specific card:
|
|
T1 line code parameters for the HS-4/1 and
|
|
E1 line code parameters for the HS-4/2.
|
|
This parameter has the same values as dsx1LineType in T1/E1
|
|
MIB (RFC-1406). The parameters in dsx1LineType are:
|
|
other (1)
|
|
dsx1ESF (2)
|
|
dsx1D4 (3)
|
|
dsx1E1 (4)
|
|
dsx1E1-CRC (5)
|
|
dsx1E1-MF (6)
|
|
dsx1E1-MF-CRC (7)"
|
|
::= {prtExHs4CnfgEntry 5}
|
|
|
|
prtExHs4LineCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
b7T1 (1), --> dsx1JBZS
|
|
b8zsT1 (2), --> dsx1B8ZS
|
|
hdb3E1 (4) --> dsx1HDB3
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the line code parameter used for T1/E1
|
|
interface.
|
|
The user should select only the parameters relevant to the
|
|
specific card:
|
|
T1 line code parameters for the MPH.1/T1 and
|
|
E1 line code parameters for the MPH.1/E1.
|
|
This parameter has the same values as dsx1LineCoding in T1/E1
|
|
MIB (RFC-1406). The parameters in dsx1LineCoding are:
|
|
dsx1JBZS (1)
|
|
dsx1B8ZS (2)
|
|
dsx1HDB3 (3)
|
|
dsx1ZBTSI (4)
|
|
dsx1AMI (5)
|
|
other (6)"
|
|
::= {prtExHs4CnfgEntry 6}
|
|
|
|
prtExHs4LineLen OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
len0p133ft (2),
|
|
len134p266ft (3),
|
|
len267p399ft (4),
|
|
len400p533ft (5),
|
|
len534p655ft (6),
|
|
fcc68 (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the line length parameter used only for
|
|
T1 interfaces.
|
|
len399p533ft=len-399-533ft "
|
|
::= {prtExHs4CnfgEntry 7}
|
|
|
|
prtExHs4RestoreT OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
restoreT1secFast (2),
|
|
restoreT10sec62411 (3),
|
|
ccittE1 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time passing from the disappearance of the loss of
|
|
synchronization condition (red alarm), to the restoration
|
|
of normal service."
|
|
::= {prtExHs4CnfgEntry 8}
|
|
|
|
prtExHs4OosSig OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notsupported (2),
|
|
forcedIdle (3),
|
|
forcedBusy (4),
|
|
busyIdle (5),
|
|
idleBusy (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Out of Service signal type."
|
|
::= {prtExHs4CnfgEntry 9}
|
|
|
|
prtExHs4OosCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notsupported (2),
|
|
oosCode00H (3),
|
|
oosCode1aH (4),
|
|
oosCode54H (5),
|
|
oosCode7eH (6),
|
|
oosCode7fH (7),
|
|
oosCode98H (8),
|
|
oosCode9eH (9),
|
|
oosCoded5H (10),
|
|
oosCodee4H (11),
|
|
oosCodeffH (12)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OOS Code"
|
|
::= {prtExHs4CnfgEntry 10}
|
|
|
|
prtExHs4IdleCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Type value(00 - FF HEX), excluding 0H,8H,10H,12H,21H,24H,
|
|
42H,49H,84H,92H"
|
|
::= {prtExHs4CnfgEntry 11}
|
|
|
|
prtExHs4MfClkSrcSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
local (2),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port Tx is multiframe
|
|
synchronized with Rx multiframe of another port and the slot position of that port.
|
|
This opration is required in order to bypass signaling of PCM
|
|
voice channels.
|
|
When its value is Local(2) there is no meaning to 'prtExHs4MfClkSrcPrt'
|
|
parameter.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid"
|
|
::= {prtExHs4CnfgEntry 12}
|
|
|
|
prtExHs4MfClkSrcPrt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
inPrt1 (101)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify a port position in the mux if the
|
|
MultiFrame clock source is valid (YES).
|
|
inPrt1 - for MTML-H/E1 cards."
|
|
::= {prtExHs4CnfgEntry 13}
|
|
|
|
--
|
|
-- Hs4 Time Slot Config Table
|
|
--
|
|
prtExHs4TsCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExHs4TsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtHs4Cnfg 2}
|
|
|
|
prtExHs4TsEntry OBJECT-TYPE
|
|
SYNTAX PrtExHs4TsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExHs4TsCnfgIdx, prtExHs4TsSltIdx, prtExHs4TsPrtIdx, prtExHs4TsIdx }
|
|
::= { prtExHs4TsCnfgTable 1}
|
|
|
|
PrtExHs4TsEntry ::=
|
|
SEQUENCE {
|
|
prtExHs4TsCnfgIdx Integer32,
|
|
prtExHs4TsSltIdx INTEGER,
|
|
prtExHs4TsPrtIdx INTEGER,
|
|
prtExHs4TsIdx Integer32,
|
|
prtExHs4TsIConSlot INTEGER,
|
|
prtExHs4TsIConPrt INTEGER,
|
|
prtExHs4TsIConTs Integer32
|
|
}
|
|
|
|
prtExHs4TsCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtExHs4TsEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExHs4TsSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid"
|
|
::= { prtExHs4TsEntry 2}
|
|
|
|
prtExHs4TsPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
Hs4/T1 and Hs4/T1 cards have only one external interface."
|
|
::= { prtExHs4TsEntry 3}
|
|
|
|
prtExHs4TsIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique time slot position.
|
|
The valid time slots are:
|
|
1..24 for T1 Card and
|
|
1..31 for E1 interface.
|
|
In G732S-E1 lines, time slot 16 is not valid for data,
|
|
it is dedicated to multiframe synchronization bits
|
|
and voice signaling."
|
|
::= { prtExHs4TsEntry 4}
|
|
|
|
prtExHs4TsIConSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noConnect (2),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
split (100)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the specified time slot is
|
|
connected/routed internally in the Agent and to which card
|
|
it is connected.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid.
|
|
split - will be used when the Src TS is connected to more
|
|
than one slot OR more than one port (each needing
|
|
less than a whole TS)."
|
|
::= {prtExHs4TsEntry 5}
|
|
|
|
prtExHs4TsIConPrt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
exPrt11 (11) ,
|
|
exPrt12 (12) ,
|
|
noConnect (100)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the internally (In Mux)
|
|
connected/routed port."
|
|
::= {prtExHs4TsEntry 6}
|
|
|
|
prtExHs4TsIConTs OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique time slot position.
|
|
The valid time slots are:
|
|
1..24 for T1 Module and
|
|
1..31 for E1 interface.
|
|
In G732S-E1 lines time slot 16 is not valid for data,
|
|
it is dedicated for multiframe synchronization bits
|
|
and voice signaling."
|
|
::= { prtExHs4TsEntry 7}
|
|
|
|
--
|
|
-- Megaplex?000/?004 and DXC Hs-U port configuration
|
|
--
|
|
--prtExHsiCnfgTable OBJECT IDENTIFIER ::= {prtHsiCnfg 1}
|
|
|
|
prtExHsiCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExHsiCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtHsiCnfg 1}
|
|
|
|
prtExHsiCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExHsiCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExHsiCnfgIdx, prtExHsiSltIdx, prtExHsiPrtIdx }
|
|
::= { prtExHsiCnfgTable 1}
|
|
|
|
PrtExHsiCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExHsiCnfgIdx Integer32,
|
|
prtExHsiSltIdx INTEGER,
|
|
prtExHsiPrtIdx Integer32,
|
|
|
|
prtExHsiConnect INTEGER,
|
|
prtExHsiRate INTEGER,
|
|
prtExHsiLinkTo INTEGER,
|
|
prtExHsiInterface INTEGER,
|
|
prtExHsiActType INTEGER
|
|
}
|
|
|
|
prtExHsiCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtExHsiCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExHsiSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted."
|
|
::= {prtExHsiCnfgEntry 2}
|
|
|
|
prtExHsiPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
-- {
|
|
-- exPrt1 (1),
|
|
-- exPrt2 (2),
|
|
-- exPrt3 (3),
|
|
-- exPrt4 (4),
|
|
-- exPrt5 (5),
|
|
-- exPrt6 (6),
|
|
-- exPrt7 (7),
|
|
-- exPrt8 (8),
|
|
-- exPrt9 (9),
|
|
-- exPrt10 (10),
|
|
-- exPrt11 (11),
|
|
-- exPrt12 (12)
|
|
-- }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique port identifier within the card.
|
|
For MP : 1..12
|
|
For DXC: 111 .. 2531. See DXC R6 spec for port index convention.
|
|
For FCD-A, 'S' Interface external ports: 131, 141, 151, 161."
|
|
::= {prtExHsiCnfgEntry 3}
|
|
|
|
prtExHsiConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3),
|
|
v51 (4),
|
|
v52 (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be considered in
|
|
any of the mux algorithms.
|
|
v51 - this port is connected to a V5.1 interface. All rest of the
|
|
values will be 'notApplicable' in this case. V5 MIB will be
|
|
used instead.
|
|
v52 - this port is connected to a V5.2 interface. All rest of the
|
|
values will be 'notApplicable' in this case. V5 MIB will be
|
|
used instead."
|
|
::= {prtExHsiCnfgEntry 4}
|
|
|
|
prtExHsiRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r600bps (2),
|
|
r1200bps (3),
|
|
r2400bps (4),
|
|
r4800bps (5),
|
|
r9600bps (6),
|
|
r19200bps (7),
|
|
r38400bps (8),
|
|
r48kbps (9),
|
|
r56kbps (10),
|
|
r64kbps (11),
|
|
r128kbps (12),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the port speed."
|
|
::= {prtExHsiCnfgEntry 5}
|
|
|
|
prtExHsiLinkTo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"It indicates the slot of the main link card to which the HS-? card
|
|
is mapped.
|
|
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
|
|
and prtGenCnfgLinkToPort."
|
|
::= {prtExHsiCnfgEntry 6}
|
|
|
|
prtExHsiInterface OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
lt (1),
|
|
nt (2),
|
|
te (3),
|
|
lt1 (4),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"It indicates the interface type:
|
|
lt = line termination
|
|
nt = network termination
|
|
te = terminal equipment.
|
|
lt1 - for ASMi-31 connection (not ISDN)
|
|
For MP:
|
|
For HS-U/I only 'lt' and 'nt' are applicable.
|
|
For HS-U/1 only 'lt' is applicable.
|
|
For HS-S , only 'te' and 'nt' are applicable.
|
|
For HS-U, this object is not applicable.
|
|
For HS-U6, HS-U12, are applicable: 'lt'=lt-i,'nt'=nt-i, lt1.
|
|
For DXC:
|
|
For HS-U8, HS-U16, are applicable: 'lt'=LT-I,'nt'=NT-I, 'lt1'=LT-1."
|
|
::= {prtExHsiCnfgEntry 7}
|
|
|
|
prtExHsiActType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
type1 (2),
|
|
type2 (3),
|
|
type3 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"It indicates the Activation Type. Activation Type is the Synchronization
|
|
type towards the PBX. It is applicable only when prtExHsiInterface=nt.
|
|
notApplicable - for cards that do not support this object, or when
|
|
prtExHsiInterface is NOT nt."
|
|
::= {prtExHsiCnfgEntry 8}
|
|
|
|
|
|
--prtInHsiCnfgTable OBJECT IDENTIFIER ::= {prtHsiCnfg 2}
|
|
--This table is not applicable for MP-2100 HS-U card type
|
|
|
|
prtInHsiCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtInHsiCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry.
|
|
This table is not applicable for MP-2100 HS-U card type."
|
|
::= {prtHsiCnfg 2}
|
|
|
|
prtInHsiCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtInHsiCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtInHsiCnfgIdx, prtInHsiSltIdx, prtInHsiPrtIdx }
|
|
::= { prtInHsiCnfgTable 1}
|
|
|
|
PrtInHsiCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtInHsiCnfgIdx Integer32,
|
|
prtInHsiSltIdx INTEGER,
|
|
prtInHsiPrtIdx Integer32,
|
|
|
|
prtInHsiConnect INTEGER,
|
|
prtInHsiRate INTEGER,
|
|
prtInHsiConcentratedTo Integer32
|
|
}
|
|
|
|
prtInHsiCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtInHsiCnfgEntry 1}
|
|
|
|
prtInHsiSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique slot position where
|
|
the card is inserted."
|
|
::= {prtInHsiCnfgEntry 2}
|
|
|
|
prtInHsiPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique port identifier within the card.
|
|
Valid values for MP: inPrt1 (101) .. inPrt48 (148).
|
|
Valid values for DXC: 11012.. 25316. See DXC R6 spec for port index convention."
|
|
::= {prtInHsiCnfgEntry 3}
|
|
|
|
prtInHsiConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be considered in
|
|
any of the mux algorithms."
|
|
::= {prtInHsiCnfgEntry 4}
|
|
|
|
prtInHsiRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r600bps (2),
|
|
r1200bps (3),
|
|
r2400bps (4),
|
|
r4800bps (5),
|
|
r9600bps (6),
|
|
r19200bps (7),
|
|
r38400bps (8),
|
|
r48kbps (9),
|
|
r56kbps (10),
|
|
r64kbps (11),
|
|
r128kbps (12),
|
|
concentrated (13),
|
|
notConnected (100),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the port speed.
|
|
For HS-U/I and HS-S ports:
|
|
2 bit - up to 9600bps
|
|
4 bit - 19200bps
|
|
8 bit - 38400bps .. 64kbps.
|
|
concentrated - this D channel goes to a Concentration channel,
|
|
that represents many channels that this value was
|
|
selected for them. The Concentrated channel is an
|
|
Internal D Channel of the same card.
|
|
This value is applicable only for D channels, except
|
|
Concentration channel itself.
|
|
--for HS-S and HS-U/I cards the Concentration channel
|
|
will always be: internal-13
|
|
--for MP-2200 HS-S12, HS-S6, HS-U12, HS-U6 and
|
|
DXC HS-U8 and HS-U16 cards, the Concentration channel
|
|
is selected via the prtInHsiConcentratedTo object.
|
|
notConnected - same as prtInHsiConnect=no."
|
|
::= {prtInHsiCnfgEntry 5}
|
|
|
|
prtInHsiConcentratedTo OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Concentration D Channel of the prtInHsiPrtIdx port.
|
|
The port always belongs to the same card as prtInHsiPrtIdx port.
|
|
This object is applicable only when prtInHsiRate=concentrated.
|
|
Valid values:
|
|
- notApplicable: 255
|
|
- for MP-2200: HS-S12, HS-U12 cards: inPrt37 (137) .. inPrt48 (148).
|
|
HS-S6, HS-U6 cards: inPrt19 (119) .. inPrt24 (124).
|
|
- for DXC: HS-U8 cards: 112 .. 254
|
|
HS-U16 cards: 112 .. 258. See DXC R6 spec for port index
|
|
convention."
|
|
::= {prtInHsiCnfgEntry 6}
|
|
|
|
--
|
|
-- Megaplex?000/?004 Hs-R and HS-U port configuration
|
|
-- DXC HS-U8, HS-U16 port configuration for Interface=LT-1
|
|
--
|
|
--prtExHsrCnfgTable OBJECT IDENTIFIER ::= {prtHsrCnfg 1}
|
|
|
|
prtExHsrCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExHsrCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtHsrCnfg 1}
|
|
|
|
prtExHsrCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExHsrCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExHsrCnfgIdx, prtExHsrSltIdx, prtExHsrPrtIdx }
|
|
::= { prtExHsrCnfgTable 1}
|
|
|
|
PrtExHsrCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExHsrCnfgIdx Integer32,
|
|
prtExHsrSltIdx INTEGER,
|
|
prtExHsrPrtIdx Integer32,
|
|
|
|
prtExHsrConnect INTEGER,
|
|
prtExHsrProtocol INTEGER,
|
|
prtExHsrRate INTEGER,
|
|
prtExHsrDataBits INTEGER,
|
|
prtExHsrParity INTEGER,
|
|
prtExHsrStopBits INTEGER,
|
|
prtExHsrCts INTEGER,
|
|
prtExHsrClkMode INTEGER,
|
|
prtExHsrLinkTo INTEGER,
|
|
prtExHsrDcdDsr INTEGER,
|
|
prtExHsrOperMode INTEGER,
|
|
prtExHsrRtsDtr INTEGER,
|
|
prtExHsrLlbEnable INTEGER,
|
|
prtExHsrRlbEnable INTEGER,
|
|
prtExHsrRateAdapt INTEGER,
|
|
prtExHsrRemoteModem INTEGER ,
|
|
prtExHsrEncapsMode INTEGER
|
|
}
|
|
|
|
prtExHsrCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtExHsrCnfgEntry 1}
|
|
|
|
prtExHsrSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique slot position where
|
|
the card is inserted."
|
|
::= {prtExHsrCnfgEntry 2}
|
|
|
|
prtExHsrPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique prt identifier within the card.
|
|
Valid values:
|
|
For MP:
|
|
- For HS-R cards: exPrt1 (1) .. exPrt4 (4)
|
|
- For HS-U/1 cards: inPrt1 (101) .. inPrt4 (104)
|
|
- For HS-S12, HS-S6, HS-U12, HS-U6 cards:
|
|
exPrt1 (1) .. exPrt12 (12).
|
|
This MIB table is used only for LT-1 interface.
|
|
For DXC:
|
|
- For HS-U8, HS-U16 cards:
|
|
111 .. 2531 (See DXC R6 spec for port index convention).
|
|
This MIB table is used only for LT-1 interface."
|
|
::= {prtExHsrCnfgEntry 3}
|
|
|
|
prtExHsrConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the port should be considered in
|
|
any of the mux algorithms."
|
|
::= {prtExHsrCnfgEntry 4}
|
|
|
|
prtExHsrProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
sync (2),
|
|
async (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the protocol."
|
|
::= {prtExHsrCnfgEntry 5}
|
|
|
|
prtExHsrRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r600bps (2),
|
|
r1200bps (3),
|
|
r2400bps (4),
|
|
r4800bps (5),
|
|
r9600bps (6),
|
|
r19200bps (7),
|
|
r38400bps (8),
|
|
r48kbps (9),
|
|
r56kbps (10),
|
|
r64kbps (11),
|
|
r16000bps (12),
|
|
r32000bps (13),
|
|
r57600bps (14),
|
|
r115200bps(15),
|
|
r128000bps(16),
|
|
r7200bps (17),
|
|
r14400bps (18),
|
|
r28800bps (19),
|
|
notConnected (100)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the port speed.
|
|
The 16,32,48,56,64 and 128 kbps rates are applicable only for Sync
|
|
protocol.
|
|
The 57.6 and 115.2 kbps rates are applicable only for Async
|
|
protocol.
|
|
notConnected= 0 rate."
|
|
::= {prtExHsrCnfgEntry 6}
|
|
|
|
prtExHsrDataBits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
d5bits (1),
|
|
d6bits (2),
|
|
d7bits (3),
|
|
d8bits (4),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data Bits.
|
|
This object is applicable for Async protocol only."
|
|
::= {prtExHsrCnfgEntry 7}
|
|
|
|
prtExHsrParity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3),
|
|
odd (4),
|
|
even(5),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"- For HS-R card, this object indicates if the parity bit is needed or not.
|
|
Therefore, the 'no' and 'yes; values are applicable.
|
|
- For HS-S12, HS-U12, the parity type is selected: no, odd, even.
|
|
This object is applicable for Async protocol only."
|
|
::= { prtExHsrCnfgEntry 8}
|
|
|
|
prtExHsrStopBits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
stopBits1Bit (1),
|
|
stopBits2Bits (2),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the minimum number of stop bits in
|
|
the tx async frame.
|
|
This object is applicable for Async protocol only."
|
|
::= { prtExHsrCnfgEntry 9}
|
|
|
|
prtExHsrCts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
on (2),
|
|
rts (3),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CTS.
|
|
This object is applicable for Async protocol only."
|
|
::= {prtExHsrCnfgEntry 10}
|
|
|
|
prtExHsrClkMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dce (1),
|
|
extDce (2),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock mode.
|
|
This object is applicable for Sync protocol only."
|
|
::= { prtExHsrCnfgEntry 11}
|
|
|
|
prtExHsrLinkTo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"It indicates the slot of the main link card to which the HS-R card
|
|
is mapped.
|
|
notApplicable - for HS-U/1 internal ports.
|
|
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
|
|
and prtGenCnfgLinkToPort."
|
|
::= {prtExHsrCnfgEntry 12}
|
|
|
|
prtExHsrDcdDsr OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
local (2),
|
|
endToEnd (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DCD & DSR."
|
|
::= {prtExHsrCnfgEntry 13}
|
|
|
|
|
|
prtExHsrOperMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal (2),
|
|
unidirectRx (3),
|
|
broadcast (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the operation mode of the port.
|
|
normal = bi-directional (Tx/Rx)
|
|
unidirectRx = unidirectional Rx.
|
|
broadcast = Tx upon request."
|
|
::= {prtExHsrCnfgEntry 14}
|
|
|
|
prtExHsrRtsDtr OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
local (2),
|
|
endToEnd (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RTS & DTR."
|
|
::= {prtExHsrCnfgEntry 15}
|
|
|
|
prtExHsrLlbEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable LLB."
|
|
::= {prtExHsrCnfgEntry 16}
|
|
|
|
prtExHsrRlbEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable RLB."
|
|
::= {prtExHsrCnfgEntry 17}
|
|
|
|
prtExHsrRateAdapt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
proprietary (2),
|
|
v110 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Rate Adaptation - takes a low rate and adapts it to 64Kbps.
|
|
This object specifies the means this adaptation is done by."
|
|
::= {prtExHsrCnfgEntry 18}
|
|
|
|
prtExHsrRemoteModem OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
asmi31 (2),
|
|
asmi31s2 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote modem.
|
|
asmi31s2 = ASMi-31/2 "
|
|
::= {prtExHsrCnfgEntry 19}
|
|
|
|
prtExHsrEncapsMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
bwOptimized (2),
|
|
latencyOptimized (3),
|
|
asmi31 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low Speed encapsulation method over PCM.
|
|
|
|
When Encapsulation mode is Latency optimized, only rates up to 19.2 are supported.
|
|
In this case a double number of bits occupy the Time Slot.
|
|
For up to 9.6 Kbps - 4 bits are occupied.
|
|
For 14.4 & 19.2 Kbps - 8 bits are occupied.
|
|
|
|
When Encapsulation Mode is Bandwidth Optimized:
|
|
For up to 9.6 Kbps - 2 bits are occupied.
|
|
For 14.4 & 19.2 Kbps - 4 bits are occupied.
|
|
For higher rates - 8 bits are occupied."
|
|
::= {prtExHsrCnfgEntry 20}
|
|
|
|
--
|
|
-- Megaplex?000/?004 MBE port configuration
|
|
--
|
|
|
|
prtExMbeCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExMbeCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtMbeCnfg 1}
|
|
|
|
prtExMbeCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExMbeCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExMbeCnfgIdx, prtExMbeSltIdx, prtExMbePrtIdx }
|
|
::= { prtExMbeCnfgTable 1}
|
|
|
|
PrtExMbeCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExMbeCnfgIdx Integer32,
|
|
prtExMbeSltIdx INTEGER,
|
|
prtExMbePrtIdx INTEGER,
|
|
|
|
prtExMbeLan INTEGER
|
|
}
|
|
|
|
prtExMbeCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtExMbeCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExMbeSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid."
|
|
::= {prtExMbeCnfgEntry 2}
|
|
|
|
prtExMbePrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique port identifier within the card."
|
|
::= {prtExMbeCnfgEntry 3}
|
|
|
|
prtExMbeLan OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
remote (1),
|
|
main (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the MBE port is operated
|
|
as main or remote bridge."
|
|
::= {prtExMbeCnfgEntry 4}
|
|
|
|
prtInMbeCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtInMbeCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtMbeCnfg 2}
|
|
|
|
prtInMbeCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtInMbeCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtInMbeCnfgIdx, prtInMbeSltIdx, prtInMbePrtIdx }
|
|
::= { prtInMbeCnfgTable 1}
|
|
|
|
PrtInMbeCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtInMbeCnfgIdx Integer32,
|
|
prtInMbeSltIdx INTEGER,
|
|
prtInMbePrtIdx INTEGER,
|
|
|
|
prtInMbeConnect INTEGER,
|
|
prtInMbeRate INTEGER,
|
|
prtInMbeLinkTo INTEGER
|
|
}
|
|
|
|
prtInMbeCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtInMbeCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtInMbeSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid."
|
|
::= {prtInMbeCnfgEntry 2}
|
|
|
|
prtInMbePrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inPrt1 (101)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique port identifier within the card."
|
|
::= {prtInMbeCnfgEntry 3}
|
|
|
|
prtInMbeConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be considered in
|
|
any of the mux algorithms."
|
|
::= {prtInMbeCnfgEntry 4}
|
|
|
|
prtInMbeRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r1x64eq64Kbps (1),
|
|
r2x64eq128Kbps (2),
|
|
r3x64eq192Kbps (3),
|
|
r4x64eq256Kbps (4),
|
|
r5x64eq320Kbps (5),
|
|
r6x64eq384Kbps (6),
|
|
r7x64eq448Kbps (7),
|
|
r8x64eq512Kbps (8),
|
|
r9x64eq576Kbps (9),
|
|
r10x64eq640Kbps (10),
|
|
r11x64eq704Kbps (11),
|
|
r12x64eq768Kbps (12),
|
|
r13x64eq832Kbps (13),
|
|
r14x64eq896Kbps (14),
|
|
r15x64eq960Kbps (15),
|
|
r16x64eq1024Kbps(16),
|
|
r17x64eq1088Kbps(17),
|
|
r18x64eq1152Kbps(18),
|
|
r19x64eq1216Kbps(19),
|
|
r20x64eq1280Kbps(20),
|
|
r21x64eq1344Kbps(21),
|
|
r22x64eq1408Kbps(22),
|
|
r23x64eq1472Kbps(23),
|
|
r24x64eq1536Kbps(24)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the port speed."
|
|
::= {prtInMbeCnfgEntry 5}
|
|
|
|
prtInMbeLinkTo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"It indicates the slot of the main link card to which the
|
|
MBE card is mapped.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid.
|
|
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
|
|
and prtGenCnfgLinkToPort."
|
|
::= {prtInMbeCnfgEntry 6}
|
|
|
|
|
|
--
|
|
-- Megaplex?000/?004 TRE port configuration
|
|
--
|
|
|
|
prtExTreCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExTreCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtTreCnfg 1}
|
|
|
|
prtExTreCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExTreCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExTreCnfgIdx, prtExTreSltIdx, prtExTrePrtIdx }
|
|
::= { prtExTreCnfgTable 1}
|
|
|
|
PrtExTreCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExTreCnfgIdx Integer32,
|
|
prtExTreSltIdx INTEGER,
|
|
prtExTrePrtIdx INTEGER,
|
|
|
|
prtExTreLan INTEGER,
|
|
prtExTreLanRate INTEGER
|
|
|
|
}
|
|
|
|
prtExTreCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtExTreCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExTreSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid."
|
|
::= {prtExTreCnfgEntry 2}
|
|
|
|
prtExTrePrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique port identifier within the card."
|
|
::= {prtExTreCnfgEntry 3}
|
|
|
|
prtExTreLan OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
remote (1),
|
|
main (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the TRE port is operated
|
|
as main or remote bridge.
|
|
Default=remote."
|
|
::= {prtExTreCnfgEntry 4}
|
|
|
|
prtExTreLanRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r4M (1),
|
|
r16M (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Rate of the TRE port
|
|
in Mbit/sec.
|
|
Default-r4M."
|
|
::= {prtExTreCnfgEntry 5}
|
|
|
|
|
|
|
|
prtInTreCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtInTreCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtTreCnfg 2}
|
|
|
|
prtInTreCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtInTreCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtInTreCnfgIdx, prtInTreSltIdx, prtInTrePrtIdx }
|
|
::= { prtInTreCnfgTable 1}
|
|
|
|
PrtInTreCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtInTreCnfgIdx Integer32,
|
|
prtInTreSltIdx INTEGER,
|
|
prtInTrePrtIdx INTEGER,
|
|
|
|
prtInTreConnect INTEGER,
|
|
prtInTreRate INTEGER,
|
|
prtInTreLinkTo INTEGER
|
|
}
|
|
|
|
prtInTreCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtInTreCnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtInTreSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid."
|
|
::= {prtInTreCnfgEntry 2}
|
|
|
|
prtInTrePrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inPrt1 (101)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique port identifier within the card."
|
|
::= {prtInTreCnfgEntry 3}
|
|
|
|
prtInTreConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be considered
|
|
in any of the mux algorithms."
|
|
::= {prtInTreCnfgEntry 4}
|
|
|
|
prtInTreRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r1x56eq56Kbps (1),
|
|
r1x64eq64Kbps (2),
|
|
r2x56eq112Kbps (3),
|
|
r2x64eq128Kbps (4),
|
|
r3x56eq168Kbps (5),
|
|
r3x64eq192Kbps (6),
|
|
r4x56eq224Kbps (7),
|
|
r4x64eq256Kbps (8),
|
|
r5x56eq280Kbps (9),
|
|
r5x64eq320Kbps (10),
|
|
r6x56eq336Kbps (11),
|
|
r6x64eq384Kbps (12),
|
|
r7x56eq392Kbps (13),
|
|
r7x64eq448Kbps (14),
|
|
r8x56eq448Kbps (15),
|
|
r8x64eq512Kbps (16),
|
|
r9x56eq504Kbps (17)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the port speed."
|
|
::= {prtInTreCnfgEntry 5}
|
|
|
|
prtInTreLinkTo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"It indicates the slot of the main link card to which the
|
|
MBE card is mapped.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid.
|
|
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
|
|
and prtGenCnfgLinkToPort."
|
|
::= {prtInTreCnfgEntry 6}
|
|
|
|
|
|
-- Packet VC cards.
|
|
-- This table is used for compressed voice cards with 4/8 ports.
|
|
--
|
|
|
|
prtExPVc4CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExPVc4CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtPVc4Cnfg 1}
|
|
|
|
prtExPVc4CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExPVc4CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExPVc4CnfgIdx, prtExPVc4SltIdx, prtExPVc4PrtIdx }
|
|
::= { prtExPVc4CnfgTable 1}
|
|
|
|
PrtExPVc4CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExPVc4CnfgIdx Integer32,
|
|
prtExPVc4SltIdx INTEGER,
|
|
prtExPVc4PrtIdx INTEGER,
|
|
|
|
prtExPVc4PrtType INTEGER,
|
|
prtExPVc4Connect INTEGER,
|
|
prtExPVc4IfType INTEGER,
|
|
prtExPVc4TxGain Integer32,
|
|
prtExPVc4RxGain Integer32,
|
|
prtExPVc4MaxRate INTEGER,
|
|
prtExPVc4Tc INTEGER,
|
|
prtExPVc4Oos INTEGER,
|
|
prtExPVc4EchoCanceler INTEGER,
|
|
prtExPVc4VarDelay Integer32,
|
|
prtExPVc4CongLevel Integer32,
|
|
prtExPVc4Wire INTEGER,
|
|
prtExPVc4ExtensionType INTEGER,
|
|
prtExPVc4ExtensionNumber DisplayString,
|
|
prtExPVc4OutPulsing INTEGER,
|
|
prtExPVc4HuntGroupMb INTEGER,
|
|
prtExPVc4HuntGroupIdx Integer32,
|
|
prtExPVc4AutoFaxMode INTEGER,
|
|
prtExPVc4FaxRate INTEGER,
|
|
prtExPVc4SeizeAck INTEGER,
|
|
prtExPVc4SignalingProtocol INTEGER,
|
|
prtExPVc4DelayStart Integer32,
|
|
prtExPVc4WinkMinDuration Integer32,
|
|
prtExPVc4WinkMaxDuration Integer32,
|
|
prtExPVc4GenerateTone INTEGER,
|
|
prtExPVc4CodingLaw INTEGER,
|
|
prtExPVc4GenerateRingBack INTEGER,
|
|
prtExPVc4ChannelId Integer32,
|
|
prtExPVc4PortConnection INTEGER,
|
|
prtExPVc4CoderAndRate INTEGER,
|
|
prtExPVc4DestinationNum DisplayString,
|
|
prtExPVc4DtmfRelay INTEGER,
|
|
prtExPVc4DiscOnSilence Integer32,
|
|
prtExPVc4DynamicJitter INTEGER,
|
|
prtExPVc4EandMType INTEGER,
|
|
prtExPVc4Rate Integer32,
|
|
prtExPVc4FrameSize Integer32,
|
|
prtExPVc4MultiplexInterval Integer32,
|
|
prtExPVc4TransportProtocol INTEGER,
|
|
prtExPVc4MultiFreqRelay INTEGER,
|
|
prtExPVc4MinPulseWidth Integer32,
|
|
prtExPVc4MinPowerLevel Integer32,
|
|
prtExPVc4SuperTandem INTEGER,
|
|
prtExPVc4DestIp IpAddress,
|
|
prtExPVc4DestBundle Integer32,
|
|
prtExPVc4SrcIpAddress IpAddress,
|
|
prtExPVc4SrcIpMask IpAddress,
|
|
prtExPVc4DefaultGateway IpAddress,
|
|
prtExPVc4SigPacketInterval Unsigned32
|
|
}
|
|
|
|
prtExPVc4CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtExPVc4CnfgEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExPVc4SltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted."
|
|
::= {prtExPVc4CnfgEntry 2}
|
|
|
|
prtExPVc4PrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
exPrt3 (3),
|
|
exPrt4 (4),
|
|
inPrt1(101),
|
|
inPrt2(102),
|
|
inPrt3(103),
|
|
inPrt4(104),
|
|
inPrt5(105),
|
|
inPrt6(106),
|
|
inPrt7(107),
|
|
inPrt8(108)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the port number in the selected card
|
|
(slot)."
|
|
::= {prtExPVc4CnfgEntry 3}
|
|
|
|
prtExPVc4PrtType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
eAndM (1),
|
|
fxo (2),
|
|
fxs (3),
|
|
internal(4),
|
|
s0 (5),
|
|
u (6),
|
|
sQsig (7),
|
|
uQsig (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the type of the selected port.
|
|
In Mx 30/300 phase 4: s0 & u are for Voice over ISDN.
|
|
In MX 30/300 phase 5: sQsig & uQsig are used for Voice over ISDN with Qsig option.
|
|
|
|
In MX MVC4 voice cards, each pair of ports 1-2, 3-4 may have a different type:
|
|
E&M, FXO, FXS.
|
|
In MVC4 compressed voice cards ports 1..4 have the same interface for all ports.
|
|
In MVC8 compressed voice cards each group of ports 1..4, 5..8 may have
|
|
a different type: E&M, FXO, FXS."
|
|
::= {prtExPVc4CnfgEntry 4}
|
|
|
|
prtExPVc4Connect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= {prtExPVc4CnfgEntry 5}
|
|
|
|
prtExPVc4IfType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
eAndM4wires (2),
|
|
eAndM2wires (3),
|
|
fxoGnd (4),
|
|
fxoLoop (5),
|
|
fxsGnd (6),
|
|
fxsLoop (7),
|
|
e1Framer (8),
|
|
e1Slave (9),
|
|
t1Framer (10),
|
|
t1Slave (11)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the interface type of the port.
|
|
eAndM4wires and eAndM2wires - are valid only for E&M
|
|
port type
|
|
eAndM4wires - means 2/4 wires
|
|
fxoGnd and fxoLoop - are valid only for FXO port type
|
|
fxsGnd and fxsLoop - are valid only for FXS port type
|
|
e1Framer, e1Slave, t1Framer, t1Slave - are applicable for the mvc4Pbx
|
|
cards only."
|
|
::= {prtExPVc4CnfgEntry 6}
|
|
|
|
prtExPVc4TxGain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmission gain in dB."
|
|
::= {prtExPVc4CnfgEntry 7}
|
|
|
|
prtExPVc4RxGain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reception gain in dBm."
|
|
::= {prtExPVc4CnfgEntry 8}
|
|
|
|
prtExPVc4MaxRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notConnected (1),
|
|
r4800bps (2),
|
|
r7200bps (3),
|
|
r9600bps (4),
|
|
notApplicatble (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voice rate."
|
|
::= {prtExPVc4CnfgEntry 9}
|
|
|
|
prtExPVc4Tc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
t1sec (1),
|
|
t2sec (2),
|
|
t3sec (3),
|
|
t4sec (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time interval for CIR control, in seconds. The value will
|
|
be the same for all cards' ports."
|
|
::= {prtExPVc4CnfgEntry 10}
|
|
|
|
prtExPVc4Oos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported (2),
|
|
forcedIdle (3),
|
|
forcedBusy (4),
|
|
busyIdle (5),
|
|
idleBusy (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Handling type, when connection is lost."
|
|
::= {prtExPVc4CnfgEntry 11}
|
|
|
|
prtExPVc4EchoCanceler OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Echo canceler activation."
|
|
::= {prtExPVc4CnfgEntry 12}
|
|
|
|
prtExPVc4VarDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (0..300)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum variant delay of the FR network, in msec."
|
|
::= {prtExPVc4CnfgEntry 13}
|
|
|
|
prtExPVc4CongLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (0..70)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the level of delayed data in
|
|
precents of total available dynamic memory,
|
|
for which the port will start to operate as congested.
|
|
The resolution of the parameter is 5%."
|
|
::= {prtExPVc4CnfgEntry 14}
|
|
|
|
prtExPVc4Wire OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
w2wire (1),
|
|
w4wire (2),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the wiring of the E&M port.
|
|
It is applicable only for E&M card type."
|
|
::= {prtExPVc4CnfgEntry 15}
|
|
|
|
prtExPVc4ExtensionType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ notApplicable(1),
|
|
forceConnect(2),
|
|
voiceSwitching(3),
|
|
transparent(4),
|
|
transparentPlus(5),
|
|
ipForceConnect(6),
|
|
permanentDial (7),
|
|
autoAccept (8) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the type of extension relevant for this port.
|
|
|
|
ipForceConnect (6) is used for automatic connection or automatic
|
|
dialing when the phone is off hook (hot line).
|
|
permanentDial (7) means that the call is established upon power up.
|
|
The hook may be on or off.
|
|
Permanent Dialing can be used when there is no signaling.
|
|
autoAccept (8) means that the called party in the Permanent Dialing
|
|
will accept the call from the remote side automatically
|
|
upon on or off hook."
|
|
::= {prtExPVc4CnfgEntry 16}
|
|
|
|
prtExPVc4ExtensionNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(2))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the extension number of this port.
|
|
This field is relevant only when the extension
|
|
type is voice switching and is read only if the
|
|
port is member of a hunt group."
|
|
::= {prtExPVc4CnfgEntry 17}
|
|
|
|
prtExPVc4OutPulsing OBJECT-TYPE
|
|
SYNTAX INTEGER { notApplicable(1), no(2), yes(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field indicates whether to outpulse the received
|
|
digits. It is notApplicable(1) when the extension type
|
|
is forceConnect(2)."
|
|
::= {prtExPVc4CnfgEntry 18}
|
|
|
|
prtExPVc4HuntGroupMb OBJECT-TYPE
|
|
SYNTAX INTEGER { notApplicable(1), no(2), yes(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if this port belongs to
|
|
an hunt group."
|
|
::= {prtExPVc4CnfgEntry 19}
|
|
|
|
prtExPVc4HuntGroupIdx OBJECT-TYPE
|
|
SYNTAX Integer32(0..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If it belongs to an hunt group, this fields
|
|
indicates the index of the relevant hunt group.
|
|
0 = notApplicable "
|
|
::= {prtExPVc4CnfgEntry 20}
|
|
|
|
prtExPVc4AutoFaxMode OBJECT-TYPE
|
|
SYNTAX INTEGER { notApplicable(1), no(2), yes(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if the system will switch automatically to
|
|
FAX mode when detecting FAX activity.
|
|
Default=Yes."
|
|
::= {prtExPVc4CnfgEntry 21}
|
|
|
|
prtExPVc4FaxRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notConnected (1),
|
|
r4800bps (2),
|
|
r7200bps (3),
|
|
r9600bps (4),
|
|
r12000bps (5),
|
|
r14400bps (6),
|
|
r2400bps (7),
|
|
vbdFax (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FAX initial rate.
|
|
Default=9600 bps."
|
|
::= {prtExPVc4CnfgEntry 22}
|
|
|
|
prtExPVc4SeizeAck OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter shows whether the device will acknowledge
|
|
a seize signal (On/Off Hook).
|
|
When the value is set to yes(3) & the device receives an on/off hook signal
|
|
it will transmit back an on/off hook signal.
|
|
When the value is set to no(2) & the device receives an on/off hook signal
|
|
it will NOT transmit back an on/off hook signal.
|
|
|
|
Example:
|
|
If Seize Ack Parameter = YES, when the MVC.4 receives a seize signal (Off Hook)
|
|
from the PBX it will send an Off Hook to the PBX.
|
|
|
|
The Seize Parameter is relevant for all the following cards:
|
|
MVC-4
|
|
MVC-4/E1-Framer
|
|
MVC-4/T1-DSU-Framer
|
|
MVC-4/T1-CSU-Framer
|
|
MVC-4/E1-SLAVE
|
|
MVC-4/T1-SLAVE
|
|
|
|
Default values:
|
|
Analog FXS - No (value can't be changed).
|
|
Analog FXO - Yes (value can't be changed).
|
|
Analog E&M - No (values NO/YES).
|
|
Digital E1/T1 Framer & Slave - No."
|
|
::= {prtExPVc4CnfgEntry 23}
|
|
|
|
prtExPVc4SignalingProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
delayStart (2),
|
|
immediateStart (3),
|
|
winkStart (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The signaling protocol that will be used between the PABX & the voice port.
|
|
|
|
Delay Start Protocol: the line is seized by sending an Off hook signal
|
|
and after a delay, if the called party is available (On hook)
|
|
DTMF (Dual Tone Multi Frequency) digits are sent towards the called party.
|
|
|
|
Immediate Start Protocol: the line is seized by sending an Off Hook signal
|
|
and immediately DTMF digits are sent towards the called party.
|
|
|
|
Wink start protocol: the line is seized by sending an Off Hook signal
|
|
and then the called party sends a short Off Hook wink signal.
|
|
Now the calling party starts sending DTMF digits."
|
|
::= {prtExPVc4CnfgEntry 24}
|
|
|
|
prtExPVc4DelayStart OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used only for Delay Protocol.
|
|
This is the time that the calling party will wait after sending an Off hook
|
|
signal and before sending DTMF digits to the called party.
|
|
The delay values are 100..5000 msec in intervals of 100 msec."
|
|
::= {prtExPVc4CnfgEntry 25}
|
|
|
|
prtExPVc4WinkMinDuration OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used only for Wink Protocol.
|
|
Min Duration of the Wink Signal (off hook duration from the called party).
|
|
Legal values: 40..400 msec in intervals of 10 msec."
|
|
::= {prtExPVc4CnfgEntry 26}
|
|
|
|
prtExPVc4WinkMaxDuration OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is used only for Wink Protocol.
|
|
Max Duration of the Wink Signal (off hook duration from the called party).
|
|
Legal values: 40..400 msec in intervals of 10 msec."
|
|
::= {prtExPVc4CnfgEntry 27}
|
|
|
|
prtExPVc4GenerateTone OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates whether the device (MX or MPH) should generate
|
|
dial tones for the channel.
|
|
If the value is yes (3), it generates dial tones.
|
|
If the value is no (2), the connected equipment will generate dial tones.
|
|
For example for some ISDN sets the dial tone is generated by the
|
|
phone itself while for others sets it is generated by the MX."
|
|
::= {prtExPVc4CnfgEntry 28}
|
|
|
|
prtExPVc4CodingLaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
aLAW (1),
|
|
uLAW (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Method/Law for decoding/encoding the voice
|
|
information.
|
|
aLaw(1) is the standard Law for E1 links.
|
|
uLaw(2) is the standard Law for T1 links.
|
|
|
|
This object is equal for all the ports in the specific module because
|
|
of HW limitations"
|
|
::= {prtExPVc4CnfgEntry 29}
|
|
|
|
prtExPVc4GenerateRingBack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines whether the Ring Back tone is generated locally or from the
|
|
remote end.
|
|
The default is - NO (Meaning coming from the remote end).
|
|
Yes means that the Ring Back Tone is generated locally.
|
|
Applicable only for Force Connect."
|
|
::= {prtExPVc4CnfgEntry 30}
|
|
|
|
prtExPVc4ChannelId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..256)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Channel Identifier.
|
|
According to FRF11 each voice port that works as force connect should add a
|
|
CH Id after the DLCI in the frame header.
|
|
|
|
Default : 1
|
|
|
|
Applicable only for Force Connect.
|
|
Not Applicable value will be 0."
|
|
::= {prtExPVc4CnfgEntry 31}
|
|
|
|
prtExPVc4PortConnection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
line (2),
|
|
trunk (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port connection determines whether the port is connected to a PABX (Trunk) or to
|
|
Telephone set (Line) .
|
|
|
|
It determines whether to send certain messages to the port or not.
|
|
If the type is LINE then the port generates a
|
|
ring back tone , if TRUNK it doesn't (The PBX does it)."
|
|
::= {prtExPVc4CnfgEntry 32}
|
|
|
|
prtExPVc4CoderAndRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
g7231r6300BPS (2),
|
|
g7231r5300BPS (3),
|
|
g729A8KBPS (4),
|
|
g711aLAW (5),
|
|
g711uLAW (6),
|
|
g726r16KBPS (7),
|
|
g726r24KBPS (8),
|
|
g726r32KBPS (9),
|
|
g726r40KBPS (10),
|
|
g727r16KBPS (11),
|
|
g727r24r16KBPS (12),
|
|
g727r24KBPS (13),
|
|
g727r16r32KBPS (14),
|
|
g727r32r24KBPS (15),
|
|
g727r32KBPS (16),
|
|
g727r40r16KBPS (17),
|
|
g727r40r24KBPS (18),
|
|
g727r40r32KBPS (19),
|
|
transparent (20),
|
|
netcoder6400BPS (21),
|
|
netcoder7200BPS (22),
|
|
netcoder8KBPS (23),
|
|
netcoder8800BPS (24),
|
|
netcoder9600BPS (25),
|
|
lowBitRateR2660BPS (26),
|
|
amr4750BPS (27), -- Adaptive Multirate Coders of GSM
|
|
amr5150BPS (28),
|
|
amr5900BPS (29),
|
|
amr6700BPS (30),
|
|
amr7400BPS (31),
|
|
amr7950BPS (32),
|
|
amr10200BPS (33),
|
|
amr12200BPS (34)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Coder and Rate for the Voice Compression.
|
|
In MPH: Relevant for MVC-8 card only."
|
|
::= {prtExPVc4CnfgEntry 33}
|
|
|
|
prtExPVc4DestinationNum OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination phone number: 0 to 22 digits.
|
|
Applicable for Auto Dial - ipForceConnect(6), Permanent Dial and
|
|
Auto Accept Extension Types.
|
|
|
|
Default: Null String"
|
|
::= {prtExPVc4CnfgEntry 34}
|
|
|
|
prtExPVc4DtmfRelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When DTMF RELAY is disabled, the DTMF digits (dialed by the user)
|
|
are transmitted as compressed voice and in the remote unit are decompressed.
|
|
|
|
When DTMF RELAY is enabled, the DTMF digits are detected at the near side and not
|
|
transmitted as voice. Instead, only an indication of what digits were
|
|
dialed are transmitted and in the far end the tone is regenerated."
|
|
::= {prtExPVc4CnfgEntry 35}
|
|
|
|
prtExPVc4DiscOnSilence OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No. of silenced seconds after which the call will be disconected.
|
|
A value of 0 means that there will be no disconnect when there is silence.
|
|
Possible values: 0 - 900 sec."
|
|
::= {prtExPVc4CnfgEntry 36}
|
|
|
|
prtExPVc4DynamicJitter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MVC8 uses two mechanisms to overcome the network delay.
|
|
The first one is a static jitter buffer which holds a constant buffer of up
|
|
to 300 Msec and can be controled by the JITTER parameter (prtExPVc4VarDelay).
|
|
The second one is the dynamic jitter which calculates, in real time,
|
|
the network delay and handles a jitter buffer dynamically.
|
|
The dynamic mechanism that is implemented in MVC8, was intended to overcome
|
|
network delay yet when the network bursts, the MVC8 dynamic mechanism is
|
|
not able to overcome the delay.
|
|
Therefore it is better not to use the dynamic jitter
|
|
(DISABLE - should be the default) where bursts may occur often."
|
|
::= {prtExPVc4CnfgEntry 37}
|
|
|
|
prtExPVc4EandMType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
type1 (2),
|
|
type2 (3),
|
|
type3 (4),
|
|
ssdc5 (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the signaling type on the E&M analog side.
|
|
The analog signaling includes voltage, no. of pins and other parameters."
|
|
::= {prtExPVc4CnfgEntry 38}
|
|
|
|
prtExPVc4Rate OBJECT-TYPE
|
|
SYNTAX Integer32 (0..31)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the Rate of the port in TS units. It is used by VF-30 card family.
|
|
0 = NA = port is not intended to be connected; therefore, no Rate."
|
|
::= {prtExPVc4CnfgEntry 39}
|
|
|
|
prtExPVc4FrameSize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the maximum size in Bytes of the multiplexed frame.
|
|
In some cases this must be limited to avoid IP fragmentation,
|
|
which makes the multiplexing useless, and can also decrease
|
|
the damage in case of frame loss.
|
|
Valid range: 100..1461.
|
|
notApplicable=0."
|
|
::= {prtExPVc4CnfgEntry 40}
|
|
|
|
prtExPVc4MultiplexInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the maximum amout of time (msec.) between multiplexed frames
|
|
that are sent.
|
|
|
|
For Vmux-400/420 devices:
|
|
It defines the Payload Packetizing Interval.
|
|
|
|
Valid values: 10-90 msec.
|
|
notApplicable=0."
|
|
::= {prtExPVc4CnfgEntry 41}
|
|
|
|
prtExPVc4TransportProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
ptp (2),
|
|
aal2oMpls (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transport Protocol.
|
|
ptp = point to point.
|
|
aal2oMpls = AAL2 over MPLS."
|
|
::= {prtExPVc4CnfgEntry 42}
|
|
|
|
prtExPVc4MultiFreqRelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables/disables Multi Frequency Signaling Detection."
|
|
::= {prtExPVc4CnfgEntry 43}
|
|
|
|
prtExPVc4MinPulseWidth OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the minimum Pulse Width in msec.
|
|
Valid values: 45-100 msec.
|
|
notApplicable=0."
|
|
::= {prtExPVc4CnfgEntry 44}
|
|
|
|
prtExPVc4MinPowerLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the minimum Power Level in dBm.
|
|
Valid values: -1..-35 dBm."
|
|
::= {prtExPVc4CnfgEntry 45}
|
|
|
|
prtExPVc4SuperTandem OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Super Tandem feature provides end to end compression
|
|
over multiple hops, solving the double compression problem
|
|
detected in Voice compressing systems.
|
|
The Super Tandem, when enabled, allows transmission of
|
|
compressed voice between a few devices and eliminates the
|
|
need to decompress an recompress it over each voice card and
|
|
PBX, thus improving voice quality and reducing delay."
|
|
::= {prtExPVc4CnfgEntry 46}
|
|
|
|
prtExPVc4DestIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the destination IP Address."
|
|
::= {prtExPVc4CnfgEntry 47}
|
|
|
|
prtExPVc4DestBundle OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the destination Bundle at the
|
|
far-end device."
|
|
::= {prtExPVc4CnfgEntry 48}
|
|
|
|
prtExPVc4SrcIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the Source IP Address."
|
|
::= {prtExPVc4CnfgEntry 49}
|
|
|
|
prtExPVc4SrcIpMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the Source IP Mask."
|
|
::= {prtExPVc4CnfgEntry 50}
|
|
|
|
prtExPVc4DefaultGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the Default Gateway for this interface."
|
|
::= {prtExPVc4CnfgEntry 51}
|
|
|
|
prtExPVc4SigPacketInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the Signaling Packetizing Interval,
|
|
which is the maximum time interval, measured in msec (milliseconds),
|
|
between multiplexed signaling frames."
|
|
::= { prtExPVc4CnfgEntry 52 }
|
|
|
|
|
|
--
|
|
-- Packet VC4 card
|
|
-- External port Dlci table
|
|
--
|
|
prtExPVc4DlciTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExPVc4DlciEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
at the TmpCnfg entry."
|
|
::= {prtPVc4Cnfg 2}
|
|
|
|
prtExPVc4DlciEntry OBJECT-TYPE
|
|
SYNTAX PrtExPVc4DlciEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExPVc4DlciCnfgIdx, prtExPVc4DlciSltIdx, prtExPVc4DlciPrtIdx}
|
|
::= { prtExPVc4DlciTable 1}
|
|
|
|
PrtExPVc4DlciEntry ::=
|
|
SEQUENCE {
|
|
prtExPVc4DlciCnfgIdx Integer32,
|
|
prtExPVc4DlciSltIdx INTEGER,
|
|
prtExPVc4DlciPrtIdx INTEGER,
|
|
|
|
prtExPVc4DlciValid INTEGER,
|
|
prtExPVc4DlciIConSlt INTEGER,
|
|
prtExPVc4DlciIConPrt INTEGER,
|
|
prtExPVc4DlciIConDlci Integer32,
|
|
|
|
prtExPVc4DlciTxBc INTEGER,
|
|
prtExPVc4DlciTxBe INTEGER,
|
|
prtExPVc4DlciRxBc INTEGER,
|
|
prtExPVc4DlciRxBe INTEGER,
|
|
|
|
prtExPVc4DlciPriority Integer32,
|
|
|
|
prtExPVc4DlciStatus INTEGER
|
|
}
|
|
|
|
|
|
prtExPVc4DlciCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtExPVc4DlciEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
prtExPVc4DlciSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid"
|
|
::= { prtExPVc4DlciEntry 2}
|
|
|
|
prtExPVc4DlciPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique internal port number.
|
|
VC4 cards have four external ports."
|
|
::= { prtExPVc4DlciEntry 3}
|
|
|
|
|
|
prtExPVc4DlciValid OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the attributes in this
|
|
entry are valid or not. The user can add/delete pvc (dlci
|
|
to dlci connection) by modifing this object"
|
|
::= { prtExPVc4DlciEntry 4}
|
|
|
|
prtExPVc4DlciIConSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noConnect (2),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position In the Mux
|
|
(Agent) where the dlci is routed to.
|
|
In the ?004 Unit the entries io6(10)..io16) are not valid"
|
|
::= { prtExPVc4DlciEntry 5}
|
|
|
|
prtExPVc4DlciIConPrt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
noConnect (100),
|
|
inPrt1 (101) ,
|
|
inPrt2 (102) ,
|
|
inPrt3 (103) ,
|
|
inPrt4 (104) ,
|
|
inPrt5 (105) ,
|
|
inPrt6 (106) ,
|
|
inPrt7 (107) ,
|
|
inPrt8 (108) ,
|
|
inPrt9 (109) ,
|
|
inPrt10 (110) ,
|
|
inPrt11 (111) ,
|
|
inPrt12 (112)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port id which the dlci is
|
|
routed to."
|
|
::= { prtExPVc4DlciEntry 6}
|
|
|
|
|
|
prtExPVc4DlciIConDlci OBJECT-TYPE
|
|
SYNTAX Integer32 (1..991)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique internal connection dlci
|
|
number, the dlci is routed to."
|
|
::= { prtExPVc4DlciEntry 7}
|
|
|
|
prtExPVc4DlciTxBc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
txBc9600bps (3),
|
|
txBc14400bps (4),
|
|
txBc19200bps (5),
|
|
txBc28800bps (6),
|
|
txBc32000bps (7),
|
|
txBc38400bps (8),
|
|
txBc48000bps (9),
|
|
txBc56000bps (10),
|
|
txBc57600bps (11),
|
|
txBc64Kbps (12),
|
|
txBc128Kbps (13),
|
|
txBc192Kbps (14),
|
|
txBc256Kbps (15),
|
|
txBc320Kbps (16),
|
|
txBc384Kbps (17),
|
|
txBc448Kbps (18),
|
|
txBc512Kbps (19),
|
|
txBc768Kbps (20),
|
|
txBc1024Kbps (21),
|
|
--
|
|
--KM30 ; KM300 additional rates
|
|
--
|
|
txBc16000bps (25),
|
|
txBc112Kbps (26)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Tx committed bandwidth on
|
|
the user transmit line (or at the port receive line)."
|
|
::= { prtExPVc4DlciEntry 8}
|
|
|
|
|
|
prtExPVc4DlciTxBe OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
txBe9600bps (3),
|
|
txBe14400bps (4),
|
|
txBe19200bps (5),
|
|
txBe28800bps (6),
|
|
txBe32000bps (7),
|
|
txBe38400bps (8),
|
|
txBe48000bps (9),
|
|
txBe56000bps (10),
|
|
txBe57600bps (11),
|
|
txBe64Kbps (12),
|
|
txBe128Kbps (13),
|
|
txBe192Kbps (14),
|
|
txBe256Kbps (15),
|
|
txBe320Kbps (16),
|
|
txBe384Kbps (17),
|
|
txBe448Kbps (18),
|
|
txBe512Kbps (19),
|
|
txBe768Kbps (20),
|
|
txBe1024Kbps (21),
|
|
--
|
|
--KM30 ; KM300 additional rates
|
|
--
|
|
txBc16000bps (25),
|
|
txBc112Kbps (26)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Tx excess bandwidth on the
|
|
user transmit line (or at the port receive line)."
|
|
::= { prtExPVc4DlciEntry 9}
|
|
|
|
|
|
prtExPVc4DlciRxBc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
rxBc9600bps (3),
|
|
rxBc14400bps (4),
|
|
rxBc19200bps (5),
|
|
rxBc28800bps (6),
|
|
rxBc32000bps (7),
|
|
rxBc38400bps (8),
|
|
rxBc48000bps (9),
|
|
rxBc56000bps (10),
|
|
rxBc57600bps (11),
|
|
rxBc64Kbps (12),
|
|
rxBc128Kbps (13),
|
|
rxBc192Kbps (14),
|
|
rxBc256Kbps (15),
|
|
rxBc320Kbps (16),
|
|
rxBc384Kbps (17),
|
|
rxBc448Kbps (18),
|
|
rxBc512Kbps (19),
|
|
rxBc768Kbps (20),
|
|
rxBc1024Kbps (21),
|
|
--
|
|
--KM30 ; KM300 additional rates
|
|
--
|
|
rxBc16000bps (25),
|
|
rxBc112Kbps (26)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Rx committed bandwidth on the
|
|
user receive line (or at the port transmit line)."
|
|
::= { prtExPVc4DlciEntry 10}
|
|
|
|
|
|
prtExPVc4DlciRxBe OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
full (1),
|
|
zero (2),
|
|
rxBe9600bps (3),
|
|
rxBe14400bps (4),
|
|
rxBe19200bps (5),
|
|
rxBe28800bps (6),
|
|
rxBe32000bps (7),
|
|
rxBe38400bps (8),
|
|
rxBe48000bps (9),
|
|
rxBe56000bps (10),
|
|
rxBe57600bps (11),
|
|
rxBe64Kbps (12),
|
|
rxBe128Kbps (13),
|
|
rxBe192Kbps (14),
|
|
rxBe256Kbps (15),
|
|
rxBe320Kbps (16),
|
|
rxBe384Kbps (17),
|
|
rxBe448Kbps (18),
|
|
rxBe512Kbps (19),
|
|
rxBe768Kbps (20),
|
|
rxBe1024Kbps (21),
|
|
--
|
|
--KM30 ; KM300 additional rates
|
|
--
|
|
rxBc16000bps (25),
|
|
rxBc112Kbps (26)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique Rx excess bandwidth on the
|
|
user receive line (or at the port transmit line)."
|
|
::= { prtExPVc4DlciEntry 11}
|
|
|
|
|
|
prtExPVc4DlciPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (6..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique priority of the pvc.
|
|
6 is the lowest priority and 8 is the highest priority."
|
|
::= { prtExPVc4DlciEntry 12}
|
|
|
|
|
|
|
|
prtExPVc4DlciStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disconnected (1),
|
|
connected (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the status of the pvc. The status is
|
|
disconnected(1) when one of the sides is programmed as not
|
|
connected"
|
|
::= { prtExPVc4DlciEntry 13}
|
|
|
|
|
|
--
|
|
-- Megaplex ?000/?004 LS-6 TDM I/O family card include:
|
|
-- Ls6, Ls6V1/E, Ls6V1/O, Ls6V1/S, Ls6V2/E, Ls6V2/O, Ls6V2/S,
|
|
-- Ls6Vf/E, Ls6Vf/O, Ls6Vf/S
|
|
--
|
|
--prtExLs6CnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 1}
|
|
--prtExLs6VCnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 2}
|
|
--prtInLs6CnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 3}
|
|
|
|
--prtExLs6CnfgTable defines the parameters of the
|
|
-- LS-6 cards family external Data ports (1-6) ; LS-12 (1-12)
|
|
|
|
prtExLs6CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExLs6CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtLs6Cnfg 1}
|
|
|
|
prtExLs6CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExLs6CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExLs6CnfgIdx, prtExLs6SltIdx, prtExLs6PrtIdx }
|
|
::= {prtExLs6CnfgTable 1}
|
|
|
|
PrtExLs6CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExLs6CnfgIdx Integer32,
|
|
prtExLs6SltIdx INTEGER,
|
|
prtExLs6PrtIdx INTEGER,
|
|
prtExLs6Connect INTEGER,
|
|
prtExLs6Protocol INTEGER,
|
|
prtExLs6Rate INTEGER,
|
|
prtExLs6ClkMode INTEGER,
|
|
prtExLs6CtrlSignal INTEGER,
|
|
prtExLs6DataBits INTEGER,
|
|
prtExLs6Cts INTEGER,
|
|
prtExLs6LinkToInternal INTEGER
|
|
}
|
|
|
|
prtExLs6CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtExLs6CnfgEntry 1}
|
|
|
|
prtExLs6SltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= {prtExLs6CnfgEntry 2}
|
|
|
|
prtExLs6PrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3) ,
|
|
exPrt4 (4) ,
|
|
exPrt5 (5) ,
|
|
exPrt6 (6) ,
|
|
exPrt7 (7) ,
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
exPrt11 (11) ,
|
|
exPrt12 (12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port index."
|
|
::= {prtExLs6CnfgEntry 3}
|
|
|
|
prtExLs6Connect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= {prtExLs6CnfgEntry 4}
|
|
|
|
prtExLs6Protocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
sync (2),
|
|
async (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the protocol.
|
|
async - can be selected only for ports 1-2."
|
|
::= {prtExLs6CnfgEntry 5}
|
|
|
|
prtExLs6Rate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r300bps (2),
|
|
r600bps (3),
|
|
r1200bps (4),
|
|
r2400bps (5),
|
|
r4800bps (6),
|
|
r7200bps (7),
|
|
r8000bps (8),
|
|
r9600bps (9),
|
|
r14400bps (10),
|
|
r16000bps (11),
|
|
r19200bps (12),
|
|
r24000bps (13),
|
|
r28800bps (14),
|
|
r32000bps (15),
|
|
r38400bps (16),
|
|
r48000bps (17),
|
|
r56000bps (18),
|
|
r57600bps (19),
|
|
r64000bps (20)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port rates in bps.
|
|
g1 - contains the values : (2)-(6),(9),(12),(16)
|
|
g2 - contains the values : (7),(10),(14),(19)
|
|
g3 - contains the values : (8),(11),(13),(15),(17),(18),(20);
|
|
it is not applicable when using Async protocol.
|
|
Rates of pair ports (1-2, 3-4, 5-6) must be from the same
|
|
group."
|
|
::= {prtExLs6CnfgEntry 6}
|
|
|
|
prtExLs6ClkMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dce (1),
|
|
extDce (2),
|
|
dte1 (3),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port operation clock mode.
|
|
It is applicable for Sync protocol only ."
|
|
::= {prtExLs6CnfgEntry 7}
|
|
|
|
prtExLs6CtrlSignal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
local (2),
|
|
rts (3),
|
|
dtrAndRts (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Control Signal."
|
|
::= {prtExLs6CnfgEntry 8}
|
|
|
|
prtExLs6DataBits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
d6bits (1),
|
|
d7bits (2),
|
|
d8bits (3),
|
|
d9bits (4),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data Bits.
|
|
This object is applicable for Async protocol only."
|
|
::= {prtExLs6CnfgEntry 9}
|
|
|
|
prtExLs6Cts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
on (2),
|
|
rts (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the CTS control line
|
|
operation mode."
|
|
::= {prtExLs6CnfgEntry 10}
|
|
|
|
prtExLs6LinkToInternal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inPrt1 (101) ,
|
|
inPrt2 (102) ,
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates which internal port of the card,
|
|
the external port is linked to."
|
|
::= {prtExLs6CnfgEntry 11}
|
|
|
|
|
|
--prtExLs6VCnfgTable defines the parameters of the
|
|
-- LS-6 cards family external Voice & FAX ports (7-8)
|
|
|
|
prtExLs6VCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExLs6VCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtLs6Cnfg 2}
|
|
|
|
prtExLs6VCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExLs6VCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExLs6VCnfgIdx, prtExLs6VSltIdx, prtExLs6VPrtIdx }
|
|
::= {prtExLs6VCnfgTable 1}
|
|
|
|
|
|
PrtExLs6VCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExLs6VCnfgIdx Integer32,
|
|
prtExLs6VSltIdx INTEGER,
|
|
prtExLs6VPrtIdx INTEGER,
|
|
|
|
prtExLs6VConnect INTEGER,
|
|
prtExLs6VRate INTEGER,
|
|
prtExLs6VEchoCanceler INTEGER,
|
|
prtExLs6VIfType INTEGER,
|
|
prtExLs6VTxGain Integer32,
|
|
prtExLs6VRxGain Integer32,
|
|
prtExLs6VOos INTEGER
|
|
}
|
|
|
|
prtExLs6VCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtExLs6VCnfgEntry 1}
|
|
|
|
prtExLs6VSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= {prtExLs6VCnfgEntry 2}
|
|
|
|
prtExLs6VPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt7 (7) ,
|
|
exPrt8 (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of the port, within the card."
|
|
::= {prtExLs6VCnfgEntry 3}
|
|
|
|
prtExLs6VConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= {prtExLs6VCnfgEntry 4}
|
|
|
|
|
|
prtExLs6VRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r6400bps (2),
|
|
r7200bps (3),
|
|
r8000bps (4),
|
|
r9600bps (5),
|
|
r16000bps (6),
|
|
r24000bps (7),
|
|
r32000bps (8),
|
|
r64000bps (9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Rate (bps) used for FAX transmission and Voice coding."
|
|
::= {prtExLs6VCnfgEntry 5}
|
|
|
|
prtExLs6VEchoCanceler OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Echo canceler activation."
|
|
::= {prtExLs6VCnfgEntry 6}
|
|
|
|
prtExLs6VIfType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
w2wire (1),
|
|
w4wire (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the interface type of the port.
|
|
w4wire - is applicable only for E&M port type."
|
|
::= {prtExLs6VCnfgEntry 7}
|
|
|
|
prtExLs6VTxGain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmit gain in dBm.
|
|
E&M - values range: -17 .. 8
|
|
FXO - values range: -16 .. 4
|
|
FXS - values range: -13 .. 8 "
|
|
::= {prtExLs6VCnfgEntry 8}
|
|
|
|
prtExLs6VRxGain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receive gain in dBm.
|
|
E&M - values range: -17 .. 2
|
|
FXO - values range: -17 .. -1
|
|
FXS - values range: -17 .. 2 "
|
|
::= {prtExLs6VCnfgEntry 9}
|
|
|
|
prtExLs6VOos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
forcedIdle (1),
|
|
forcedBusy (2),
|
|
busyIdle (3),
|
|
idleBusy (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Out of Service signaling mode."
|
|
::= {prtExLs6VCnfgEntry 10}
|
|
|
|
|
|
|
|
-- Ls6 and Ls12 Internal composite channel parameters
|
|
--
|
|
|
|
prtInLs6CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtInLs6CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtLs6Cnfg 3}
|
|
|
|
prtInLs6CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtInLs6CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtInLs6CnfgIdx, prtInLs6SltIdx, prtInLs6PrtIdx }
|
|
::= {prtInLs6CnfgTable 1}
|
|
|
|
PrtInLs6CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtInLs6CnfgIdx Integer32,
|
|
prtInLs6SltIdx INTEGER,
|
|
prtInLs6PrtIdx INTEGER,
|
|
prtInLs6Connect INTEGER,
|
|
prtInLs6TandemMode INTEGER,
|
|
prtInLs6Rate INTEGER,
|
|
prtInLs6RemoteType INTEGER,
|
|
prtInLs6LinkTo INTEGER
|
|
}
|
|
|
|
prtInLs6CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtInLs6CnfgEntry 1}
|
|
|
|
prtInLs6SltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= {prtInLs6CnfgEntry 2}
|
|
|
|
prtInLs6PrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inPrt1 (101),
|
|
inPrt2 (102)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique internal port index."
|
|
::= {prtInLs6CnfgEntry 3}
|
|
|
|
prtInLs6Connect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be considered in
|
|
any of the mux algorithms. It also affects all the module
|
|
considerations because the module has only one Internal
|
|
interface which is the composite channel."
|
|
::= {prtInLs6CnfgEntry 4}
|
|
|
|
prtInLs6TandemMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noTandem (1),
|
|
tandemMaster (2),
|
|
tandemSlave (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Tandem Mode.
|
|
tandemSlave - is valid only for an LS-6 card having on
|
|
the (current slot-1) an LS-6 card with 'tandemMaster' mode."
|
|
::= {prtInLs6CnfgEntry 5}
|
|
|
|
prtInLs6Rate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r32Kbps (1),
|
|
r56Kbps (2),
|
|
r64Kpbs (3),
|
|
r128Kbps (4),
|
|
r256Kbps (5),
|
|
r384Kbps (6),
|
|
r192Kbps (7),
|
|
r512Kbps (8),
|
|
r768Kbps (9),
|
|
r14400bps(10)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Main Rate in Kbps."
|
|
::= {prtInLs6CnfgEntry 6}
|
|
|
|
prtInLs6RemoteType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ls6 (1),
|
|
km2kSlave (2),
|
|
km2kStandalone (3),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote Type.
|
|
notApplicable - when prtInLs6TandemMode=tandemSlave "
|
|
::= {prtInLs6CnfgEntry 7}
|
|
|
|
prtInLs6LinkTo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"It indicates the slot of the main link card to which the
|
|
Ls6 card is mapped.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
|
|
notApplicable - when prtInLs6TandemMode=tandemSlave.
|
|
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
|
|
and prtGenCnfgLinkToPort. "
|
|
::= {prtInLs6CnfgEntry 8}
|
|
|
|
--
|
|
-- Megaplex?000/?004 VC-3 TDM I/O family port.
|
|
-- (VC3/E&M,VC3/FXO,VC3/FXS)
|
|
--
|
|
--
|
|
|
|
--prtExVc3CnfgTable defines the parameters of the
|
|
-- VC-3 and VF-3 cards family external ports
|
|
|
|
prtExVc3CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExVc3CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtVc3Cnfg 1}
|
|
|
|
prtExVc3CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExVc3CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExVc3CnfgIdx, prtExVc3SltIdx, prtExVc3PrtIdx }
|
|
::= { prtExVc3CnfgTable 1}
|
|
|
|
PrtExVc3CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExVc3CnfgIdx Integer32,
|
|
prtExVc3SltIdx INTEGER,
|
|
prtExVc3PrtIdx INTEGER,
|
|
|
|
prtExVc3Connect INTEGER,
|
|
prtExVc3TransGain Integer32,
|
|
prtExVc3ReceiveGain Integer32,
|
|
prtExVc3Wire INTEGER,
|
|
prtExVc3Rate INTEGER,
|
|
prtExVc3EchoCanceler INTEGER
|
|
}
|
|
|
|
prtExVc3CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtExVc3CnfgEntry 1}
|
|
|
|
prtExVc3SltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= {prtExVc3CnfgEntry 2}
|
|
|
|
prtExVc3PrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1) ,
|
|
exPrt2 (2) ,
|
|
exPrt3 (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of the port, within the card."
|
|
::= {prtExVc3CnfgEntry 3}
|
|
|
|
prtExVc3Connect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= {prtExVc3CnfgEntry 4}
|
|
|
|
prtExVc3TransGain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmit gain in dBm."
|
|
::= {prtExVc3CnfgEntry 5}
|
|
|
|
prtExVc3ReceiveGain OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receive gain in dBm."
|
|
::= {prtExVc3CnfgEntry 6}
|
|
|
|
prtExVc3Wire OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
w2wire (1),
|
|
w4wire (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is equal for all the ports in the specific
|
|
card because of HW limitations"
|
|
::= {prtExVc3CnfgEntry 7}
|
|
|
|
prtExVc3Rate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r9600bps (1),
|
|
r4800bps (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Rate in bps."
|
|
::= {prtExVc3CnfgEntry 8}
|
|
|
|
prtExVc3EchoCanceler OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Echo canceler activation. The value will be the same for
|
|
all the card's external ports."
|
|
::= {prtExVc3CnfgEntry 9}
|
|
|
|
--prtInVc3CnfgTable defines the parameters of the
|
|
-- VC-3 or VF-3 cards family internal ports
|
|
|
|
prtInVc3CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtInVc3CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtVc3Cnfg 2}
|
|
|
|
prtInVc3CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtInVc3CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtInVc3CnfgIdx, prtInVc3SltIdx, prtInVc3PrtIdx }
|
|
::= { prtInVc3CnfgTable 1}
|
|
|
|
PrtInVc3CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtInVc3CnfgIdx Integer32,
|
|
prtInVc3SltIdx INTEGER,
|
|
prtInVc3PrtIdx INTEGER,
|
|
|
|
prtInVc3Connect INTEGER,
|
|
prtInVc3Rate INTEGER,
|
|
prtInVc3Oos INTEGER,
|
|
prtInVc3LinkTo INTEGER
|
|
|
|
}
|
|
|
|
prtInVc3CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtInVc3CnfgEntry 1}
|
|
|
|
prtInVc3SltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= {prtInVc3CnfgEntry 2}
|
|
|
|
prtInVc3PrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inPrt1 (101)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of the port, within the card."
|
|
::= {prtInVc3CnfgEntry 3}
|
|
|
|
prtInVc3Connect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= {prtInVc3CnfgEntry 4}
|
|
|
|
prtInVc3Rate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r32000bps (1),
|
|
r16000bps (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Rate in bps."
|
|
::= {prtInVc3CnfgEntry 5}
|
|
|
|
prtInVc3Oos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
forcedIdle (1),
|
|
forcedBusy (2),
|
|
busyIdle (3),
|
|
idleBusy (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This object is equal for all the ports in the specific
|
|
card because of HW limitations"
|
|
::= {prtInVc3CnfgEntry 6}
|
|
|
|
prtInVc3LinkTo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This attribute indicates the slot of the ML card to which
|
|
the VC card is mapped.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
|
|
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
|
|
and prtGenCnfgLinkToPort."
|
|
::= {prtInVc3CnfgEntry 7}
|
|
|
|
|
|
--
|
|
-- Megaplex?000/?004 VC-3 TDM I/O family port.
|
|
-- (VC-PBX, VC-PBX/T1,VC-PBX/E1)
|
|
--
|
|
--
|
|
|
|
--prtExVcPbxCnfgTable defines the parameters of the
|
|
-- VC-PBX or VF-PBX cards family external ports
|
|
|
|
prtExVcPbxCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExVcPbxCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtVcPbxCnfg 1}
|
|
|
|
prtExVcPbxCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtExVcPbxCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExVcPbxCnfgIdx, prtExVcPbxSltIdx, prtExVcPbxPrtIdx }
|
|
::= { prtExVcPbxCnfgTable 1}
|
|
|
|
PrtExVcPbxCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtExVcPbxCnfgIdx Integer32,
|
|
prtExVcPbxSltIdx INTEGER,
|
|
prtExVcPbxPrtIdx INTEGER,
|
|
|
|
prtExVcPbxConnect INTEGER,
|
|
prtExVcPbxGroup INTEGER,
|
|
prtExVcPbxTransparent INTEGER,
|
|
prtExVcPbxTransSignalTs Integer32,
|
|
prtExVcPbxFrame INTEGER,
|
|
prtExVcPbxRestoreTime INTEGER,
|
|
prtExVcPbxLineCode INTEGER,
|
|
prtExVcPbxLineLength INTEGER,
|
|
prtExVcPbxLinkTo INTEGER,
|
|
prtExVcPbxSignalOper INTEGER,
|
|
prtExVcPbxIdleCode INTEGER
|
|
}
|
|
|
|
prtExVcPbxCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtExVcPbxCnfgEntry 1}
|
|
|
|
prtExVcPbxSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= {prtExVcPbxCnfgEntry 2}
|
|
|
|
prtExVcPbxPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of the port, within the card."
|
|
::= {prtExVcPbxCnfgEntry 3}
|
|
|
|
prtExVcPbxConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= {prtExVcPbxCnfgEntry 4}
|
|
|
|
prtExVcPbxGroup OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group object links together several VC-PBX cards,
|
|
concerning compression of the same input T1/E1 link
|
|
time-slots.
|
|
When ports of different slots have the same group, they are
|
|
linked.
|
|
When ports have a different group, they are not linked.
|
|
For VC-PBX/T1 and E1 cards, this object is - their own
|
|
IO Slot.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= {prtExVcPbxCnfgEntry 5}
|
|
|
|
prtExVcPbxTransparent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the Transparent transfer
|
|
of Time-Slots is required or not.
|
|
Time-Slots transferred by Transparent, will not be
|
|
compressed.
|
|
no - applicable only for VC-PBX/T1 and VC-PBX/E1 cards
|
|
yes - applicable only for VC-PBX/T1 and VC-PBX/E1 cards
|
|
notApplicable - only for VC-PBX cards."
|
|
::= {prtExVcPbxCnfgEntry 6}
|
|
|
|
prtExVcPbxTransSignalTs OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the ML Time-Slot dedicated to
|
|
the signaling of the PABX Transparent TSs.
|
|
None = 255.
|
|
When prtExVcPbxTransparent=no this object's value=None (255)
|
|
When prtExVcPbxTransparent=notApplicable, this object's
|
|
value=None (255).
|
|
When prtExVcPbxTransparent=yes:
|
|
- for VC-PBX/T1 ports, this object's valid values are 1..16
|
|
or None (255).
|
|
- for VC-PBX/E1 ports, this object's value will be 16 or None
|
|
(255)."
|
|
::= {prtExVcPbxCnfgEntry 7}
|
|
|
|
prtExVcPbxFrame OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
esfT1 (2), --> dsx1ESF
|
|
sfT1 (3), --> dsx1D4
|
|
g732nE1 (4), --> dsx1E1
|
|
g732nE1CRC (5), --> dsx1E1-CRC
|
|
g732sE1 (6), --> dsx1E1-MF
|
|
g732sE1CRC (7), --> dsx1E1-MF-CRC
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the frame parameter for T1/E1 interface.
|
|
The user should select only the parameters which are relevant
|
|
to the specific card:
|
|
T1 values for the VC-PBX/T1 card.
|
|
E1 values for the VC-PBX/E1 card.
|
|
notApplicable - for the VC-PBX card.
|
|
This parameter has the same values as dsx1LineType in T1/E1
|
|
MIB (RFC-1406). The parameters in dsx1LineType are:
|
|
other (1)
|
|
esfT1 dsx1ESF (2)
|
|
sfT1 dsx1D4 (3)
|
|
g732nE1 dsx1E1 (4)
|
|
g732nE1CRC dsx1E1-CRC (5)
|
|
g732sE1 dsx1E1-MF (6)
|
|
g732sE1CRC dsx1E1-MF-CRC (7) "
|
|
::= {prtExVcPbxCnfgEntry 8}
|
|
|
|
prtExVcPbxRestoreTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
restoreT1secFast (2),
|
|
restoreT10sec62411 (3),
|
|
ccittE1 (4),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time passing from the disappearance of the loss of
|
|
synchronization condition (red alarm) to the restoration of
|
|
normal service. The options 1secFast(2) and 10sec62411(3)
|
|
for E1 interfaces are proprietary implementation of the T1
|
|
standard to the E1 interface.
|
|
ccittE1 - is applicable only for VC-PBX/E1 card
|
|
notApplicable - is applicable for VC-PBX card"
|
|
::= {prtExVcPbxCnfgEntry 9}
|
|
|
|
prtExVcPbxLineCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
b7zsT1 (1), --> dsx1JBZS
|
|
b8zsT1 (2), --> dsx1B8ZS
|
|
transT1(3), --> dsx1AMI
|
|
hdb3E1 (4), --> dsx1HDB3
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the line code parameter used for T1/E1
|
|
interface.
|
|
The user should select only the parameters which are relevant
|
|
to the specific card:
|
|
T1 line code parameters for VC-PBX/T1
|
|
E1 line code parameters for VC-PBX/E1
|
|
notApplicable - for VC-PBX
|
|
This parameter has the same values as dsx1LineCoding in T1/E1
|
|
MIB (RFC-1406). The parameters in dsx1LineCoding are:
|
|
dsx1JBZS (1)
|
|
dsx1B8ZS (2)
|
|
dsx1HDB3 (3)
|
|
dsx1ZBTSI (4)
|
|
dsx1AMI (5)
|
|
other (6)"
|
|
::= {prtExVcPbxCnfgEntry 10}
|
|
|
|
prtExVcPbxLineLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
len0p133ft (2),
|
|
len134p266ft (3),
|
|
len267p399ft (4),
|
|
len400p533ft (5),
|
|
len534p655ft (6),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the line length parameter.
|
|
It is applicable only for the VC-PBX/T1 card.
|
|
notApplicable - for the VC-PBX and VC-PBX/E1 card.
|
|
lenXXXpXXXft = len-XXX-XXXft."
|
|
::= {prtExVcPbxCnfgEntry 11}
|
|
|
|
prtExVcPbxLinkTo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object indicates the slot of the ML card to which
|
|
the VC-PBX/T1, VC-PBX/E1 card Transparent TSs are mapped.
|
|
notApplicable - for VC-PBX card AND
|
|
for VC-PBX/T1, VC-PBX/E1 cards, when prtExVcPbxTransparent=no .
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
|
|
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
|
|
and prtGenCnfgLinkToPort."
|
|
::= {prtExVcPbxCnfgEntry 12}
|
|
|
|
prtExVcPbxSignalOper OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
normal (2),
|
|
bEqA (3),
|
|
inverseA (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Signaling Operation of the
|
|
VC-PBX/T1, VC-PBX/E1 external port.
|
|
notApplicable - for VC-PBX card
|
|
normal - all 4 signaling bits are transferred.
|
|
bEqA - copy the A bit into the B bit. Applicable only for
|
|
VC-PBX/T1."
|
|
::= {prtExVcPbxCnfgEntry 13}
|
|
|
|
prtExVcPbxIdleCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
hff (2),
|
|
he4 (3),
|
|
hd5 (4),
|
|
h9e (5),
|
|
h98 (6),
|
|
h7f (7),
|
|
h7e (8),
|
|
h54 (9),
|
|
h1a (10)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines the code for transmission in empty time slots.
|
|
notApplicable - for VC-PBX card ."
|
|
::= {prtExVcPbxCnfgEntry 14}
|
|
|
|
|
|
|
|
--prtIn1p6VcPbxCnfgTable defines the parameters of the
|
|
-- VC-PBX or VF-PBX cards family internal ports 1-6
|
|
|
|
prtIn1p6VcPbxCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtIn1p6VcPbxCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtVcPbxCnfg 2}
|
|
|
|
prtIn1p6VcPbxCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtIn1p6VcPbxCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtIn1p6VcPbxCnfgIdx, prtIn1p6VcPbxSltIdx, prtIn1p6VcPbxPrtIdx }
|
|
::= { prtIn1p6VcPbxCnfgTable 1}
|
|
|
|
PrtIn1p6VcPbxCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtIn1p6VcPbxCnfgIdx Integer32,
|
|
prtIn1p6VcPbxSltIdx INTEGER,
|
|
prtIn1p6VcPbxPrtIdx INTEGER,
|
|
|
|
prtIn1p6VcPbxConnect INTEGER,
|
|
prtIn1p6VcPbxRate INTEGER,
|
|
prtIn1p6VcPbxEchoCanceler INTEGER,
|
|
prtIn1p6VcPbxPabxTs Integer32
|
|
}
|
|
|
|
prtIn1p6VcPbxCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtIn1p6VcPbxCnfgEntry 1}
|
|
|
|
prtIn1p6VcPbxSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= {prtIn1p6VcPbxCnfgEntry 2}
|
|
|
|
prtIn1p6VcPbxPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inPrt1 (101) ,
|
|
inPrt2 (102) ,
|
|
inPrt3 (103) ,
|
|
inPrt4 (104) ,
|
|
inPrt5 (105) ,
|
|
inPrt6 (106)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of the port, within the card."
|
|
::= {prtIn1p6VcPbxCnfgEntry 3}
|
|
|
|
prtIn1p6VcPbxConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= {prtIn1p6VcPbxCnfgEntry 4}
|
|
|
|
prtIn1p6VcPbxRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r4800bps (1),
|
|
r6400bps (2),
|
|
r7200bps (3),
|
|
r8000bps (4),
|
|
r9600bps (5),
|
|
r12800bps (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the port Rate.
|
|
For Normal mode (prtIn7p8VcPbxMode=normal), only part of the values
|
|
are valid (constant rate).
|
|
For Server mode (prtIn7p8VcPbxMode=server), all values are
|
|
applicable (user can select the desired compression rate). "
|
|
::= {prtIn1p6VcPbxCnfgEntry 5}
|
|
|
|
prtIn1p6VcPbxEchoCanceler OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Echo canceler activation."
|
|
::= {prtIn1p6VcPbxCnfgEntry 6}
|
|
|
|
prtIn1p6VcPbxPabxTs OBJECT-TYPE
|
|
SYNTAX Integer32 (1..31)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the PABX Time-Slot assigned to this
|
|
internal port.
|
|
For a T1 link, the valid values are: 1 .. 24.
|
|
For an E1 link, the valid values are: 1 .. 31.
|
|
This object is NOT applicable when prtIn1p6VcPbxConnect=no.
|
|
This object is applicable for all cards of VC-PBX family.
|
|
Default=the internal port index (1..6)."
|
|
::= {prtIn1p6VcPbxCnfgEntry 7}
|
|
|
|
--prtIn7p8VcPbxCnfgTable defines the parameters of the
|
|
-- VC-PBX or VF-PBX cards family internal ports 7-8
|
|
|
|
prtIn7p8VcPbxCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtIn7p8VcPbxCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtVcPbxCnfg 3}
|
|
|
|
prtIn7p8VcPbxCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtIn7p8VcPbxCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtIn7p8VcPbxCnfgIdx, prtIn7p8VcPbxSltIdx, prtIn7p8VcPbxPrtIdx }
|
|
::= { prtIn7p8VcPbxCnfgTable 1}
|
|
|
|
PrtIn7p8VcPbxCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtIn7p8VcPbxCnfgIdx Integer32,
|
|
prtIn7p8VcPbxSltIdx INTEGER,
|
|
prtIn7p8VcPbxPrtIdx INTEGER,
|
|
|
|
prtIn7p8VcPbxConnect INTEGER,
|
|
prtIn7p8VcPbxMode INTEGER,
|
|
prtIn7p8VcPbxRate INTEGER,
|
|
prtIn7p8VcPbxSignalMode INTEGER,
|
|
prtIn7p8VcPbxOos INTEGER,
|
|
prtIn7p8VcPbxLinkTo INTEGER
|
|
}
|
|
|
|
prtIn7p8VcPbxCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg"
|
|
::= {prtIn7p8VcPbxCnfgEntry 1}
|
|
|
|
prtIn7p8VcPbxSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= {prtIn7p8VcPbxCnfgEntry 2}
|
|
|
|
prtIn7p8VcPbxPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
inPrt7 (107) ,
|
|
inPrt8 (108)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of the port, within the card."
|
|
::= {prtIn7p8VcPbxCnfgEntry 3}
|
|
|
|
prtIn7p8VcPbxConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the port should be
|
|
considered in any of the mux algorithms."
|
|
::= {prtIn7p8VcPbxCnfgEntry 4}
|
|
|
|
prtIn7p8VcPbxMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal (1),
|
|
server (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the working mode of the port:
|
|
- normal - the compressed voice will be sent to an MTML
|
|
card inside the Mux.
|
|
- server - the compressed voice will be sent to the Digital
|
|
Voice connector, as a service to an outside user."
|
|
::= {prtIn7p8VcPbxCnfgEntry 5}
|
|
|
|
prtIn7p8VcPbxRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
r32Kbps (1),
|
|
r16Kbps (2),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the port Main Rate.
|
|
For Server mode (prtIn7p8VcPbxMode=server), the value will
|
|
be notApplicable. "
|
|
::= {prtIn7p8VcPbxCnfgEntry 6}
|
|
|
|
prtIn7p8VcPbxSignalMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
aBit (2),
|
|
abcBit (3),
|
|
abcdBit (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Signal Mode.
|
|
For Server mode (prtIn7p8VcPbxMode=server), the only valid
|
|
values are:
|
|
- none
|
|
- aBit "
|
|
::= {prtIn7p8VcPbxCnfgEntry 7}
|
|
|
|
prtIn7p8VcPbxOos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
forcedIdle (1),
|
|
forcedBusy (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Out of service Signaling mode."
|
|
::= {prtIn7p8VcPbxCnfgEntry 8}
|
|
|
|
prtIn7p8VcPbxLinkTo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object indicates the slot of the ML card to which
|
|
the VC card is mapped.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
|
|
For Server mode (prtIn7p8VcPbxMode=server), this object is
|
|
not applicable.
|
|
Both ports, 7 and 8 should be linked to the same Slot.
|
|
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
|
|
and prtGenCnfgLinkToPort."
|
|
::= {prtIn7p8VcPbxCnfgEntry 9}
|
|
|
|
--prtExVcPbxTsTable defines PABX Time Slots assignment of the
|
|
-- VC-PBX E1/T1 cards, VF-PBX cards , VF-24/30/48/60 T1/E1 cards
|
|
-- and VFS cards
|
|
|
|
prtExVcPbxTsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtExVcPbxTsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the table objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtVcPbxCnfg 4}
|
|
|
|
prtExVcPbxTsEntry OBJECT-TYPE
|
|
SYNTAX PrtExVcPbxTsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtExVcPbxTsCnfgIdx, prtExVcPbxTsSltIdx, prtExVcPbxTsPrtIdx, prtExVcPbxTsIdx }
|
|
::= { prtExVcPbxTsTable 1}
|
|
|
|
PrtExVcPbxTsEntry ::=
|
|
SEQUENCE {
|
|
prtExVcPbxTsCnfgIdx Integer32,
|
|
prtExVcPbxTsSltIdx INTEGER,
|
|
prtExVcPbxTsPrtIdx INTEGER,
|
|
prtExVcPbxTsIdx Integer32,
|
|
prtExVcPbxTsMode INTEGER,
|
|
prtExVcPbxTsIConSlot INTEGER,
|
|
prtExVcPbxTsIConPrt INTEGER,
|
|
prtExVcPbxTsIConTs Integer32,
|
|
prtExVcPbxTsRemPrt INTEGER,
|
|
prtExVcPbxTsRemTs Integer32,
|
|
prtExVcPbxTsRemConnID Unsigned32,
|
|
prtExVcPbxTsSourceSlot INTEGER,
|
|
prtExVcPbxTsSourcePrt Unsigned32
|
|
}
|
|
|
|
prtExVcPbxTsCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtExVcPbxTsEntry 1}
|
|
|
|
prtExVcPbxTsSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
|
|
::= { prtExVcPbxTsEntry 2}
|
|
|
|
prtExVcPbxTsPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
inPrt9 (109),
|
|
inPrt10 (110)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
VCPBX/E1, VCPBX/T1, VFPBX/E1, VFPBX/T1, VF-24/T1 and VF-30 cards
|
|
have only one external interface.
|
|
VF-48/T1 and VF-60/E1 cards have two external interfaces.
|
|
VFS cards have also internal ports."
|
|
::= { prtExVcPbxTsEntry 3}
|
|
|
|
prtExVcPbxTsIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique PABX time slot position.
|
|
The valid time slots are 1..24 for T1 cards and
|
|
1..31 for E1 cards."
|
|
::= { prtExVcPbxTsEntry 4}
|
|
|
|
prtExVcPbxTsMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unused (1),
|
|
compressed (2), -- =compressedVoice
|
|
transparent (3),
|
|
compressedCcs(4),
|
|
mng (5),
|
|
ccs1 (11),
|
|
ccs2 (12),
|
|
ccs3 (13),
|
|
ccs4 (14),
|
|
ccs5 (15),
|
|
ccs6 (16),
|
|
ccs7 (17),
|
|
ccs8 (18),
|
|
ss7n1 (41),
|
|
ss7n2 (42),
|
|
ss7n3 (43),
|
|
ss7n4 (44),
|
|
ss7n5 (45),
|
|
ss7n6 (46),
|
|
ss7n7 (47),
|
|
ss7n8 (48)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the usage, process and way of the
|
|
specific PABX TS towards its destination:
|
|
unused - the TS is not used (no processing, no destination).
|
|
compressed - the TS is used, sent for compression to an
|
|
internal port (for VF-PBX cards: 1..6 for of either
|
|
the same card or a VF-PBX card of the same group).
|
|
For VF-24/30/48/60 - 'compressed' represents 'compressed Voice'
|
|
(to differentiate it from 'compressedCcs').
|
|
In this case, the TS is compressed by an internal port (1..8).
|
|
transparent - the TS is used; no processing. It is sent
|
|
directly for Bypass to a ML card the VF port/TS is linked to.
|
|
compressedCcs - supported only by VF-24/30/48/60 cards. The TS is used;
|
|
sent for compression to the CPU.
|
|
mng - the TS is used for Management (this option is used when the
|
|
external port is connected to another product that has to be
|
|
managed via this dedicated TS.
|
|
ccs1..ccs8 - supported only by VF-24/30/48/60 cards. Compressed TS that
|
|
comes from a bundle of V5.1 or V5.2 PBX.
|
|
ss7n1..ss7n8 - supported only by VF-24/30/48/60 cards. Compressed TS that
|
|
comes from a bundle of V5.1 or V5.2 PBX. ss7n1 can work versus
|
|
Vmux having prtExPh1MlTsType=ss7(6)."
|
|
::= { prtExVcPbxTsEntry 5}
|
|
|
|
prtExVcPbxTsIConSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noConnect (2),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For VF-PBX cards, the io1..io12 values are applicable only when
|
|
prtExVcPbxTsMode=compressed. Otherwise, its value should be
|
|
noConnect.
|
|
For VF-24/30/48/60 cards:
|
|
- when prtExVcPbxTsMode=transparent or voiceTransparent, the io1..io12 values are applicable,
|
|
indicating the ML Slot this TS is connected to.
|
|
- when prtExVcPbxTsMode=compressed or compressedCcs, the value
|
|
will be the same as prtExVcPbxTsSltIdx, since the compression is
|
|
done within the same card.
|
|
- for rest of the prtExVcPbxTsMode values, the value will be: noConnect.
|
|
This object indicates whether the specified compressed/transparent
|
|
time slot is connected/routed internally in the Agent and
|
|
to which card it is connected.
|
|
For VF-PBX card, the valid selectable slots are either the current one,
|
|
(prtExVcPbxTsSltIdx), or a slot containing a VF-PBX card.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= {prtExVcPbxTsEntry 6}
|
|
|
|
prtExVcPbxTsIConPrt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
exPrt3 (3),
|
|
exPrt4 (4),
|
|
exPrt5 (5),
|
|
exPrt6 (6),
|
|
exPrt7 (7),
|
|
exPrt8 (8),
|
|
noConnect (100),
|
|
inPrt1 (101),
|
|
inPrt2 (102),
|
|
inPrt3 (103),
|
|
inPrt4 (104),
|
|
inPrt5 (105),
|
|
inPrt6 (106),
|
|
inPrt7 (107),
|
|
inPrt8 (108)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the port to which this TS is connected.
|
|
For VF-PBX cards, only inPrt1..inPrt6 ports are valid.
|
|
For VF-24/30/48/60 cards:
|
|
- for prtExVcPbxTsMode=transparent or voiceTransparent, the valid ports are
|
|
ML ports (exPrt1.. exPrt8, inPrt1.. inPrt8)
|
|
- for prtExVcPbxTsMode=compressed or compressedCcs, the valid
|
|
ports are internal ports of the same card (inPrt1..inPrt8)
|
|
noConnect - when prtExVcPbxTsIConSlot=noConnect."
|
|
::= {prtExVcPbxTsEntry 7}
|
|
|
|
prtExVcPbxTsIConTs OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the ML TS to which this TS is connected.
|
|
This object is not applicable for VF-PBX cards.
|
|
For VF-24/30/48/60 cards it is applicable only when
|
|
prtExVcPbxTsMode=transparent or voiceTransparent.
|
|
The valid time slots are 1..24 for ML T1 cards and 1..31 for ML E1 cards.
|
|
notApplicable - 255. "
|
|
::= { prtExVcPbxTsEntry 8}
|
|
|
|
prtExVcPbxTsRemPrt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
noConnect (100)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the end-point port on the Remote unit.
|
|
VF-24/T1 and VF-30/E1 cards have one external interface.
|
|
VF-48/T1 and VF-60/E1 cards have two external interfaces.
|
|
noConnect - when prtExVcPbxTsMode=unused, transparent, voiceTransparent or mng."
|
|
::= { prtExVcPbxTsEntry 9}
|
|
|
|
prtExVcPbxTsRemTs OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the end-point TS on the Remote unit.
|
|
The valid time slots are 1..24 for T1 ports and 1..31 for E1 ports.
|
|
notApplicable - 255."
|
|
::= { prtExVcPbxTsEntry 10}
|
|
|
|
prtExVcPbxTsRemConnID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Connection ID with the Remote unit.
|
|
notApplicable = 0."
|
|
::= { prtExVcPbxTsEntry 11}
|
|
|
|
prtExVcPbxTsSourceSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noConnect (2),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For VFS cards. These cards offer Compresed Voice Services for
|
|
Analog Voice ports of the MP.
|
|
This object indicates the Source Slot of the Analog Voice port we want
|
|
to compress.
|
|
io1..io12 values are applicable only when prtExVcPbxTsMode=compressed(voice).
|
|
Otherwise, its value should be noConnect.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
|
|
::= {prtExVcPbxTsEntry 12}
|
|
|
|
prtExVcPbxTsSourcePrt OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For VFS cards. These cards offer Compresed Voice Services for
|
|
Analog Voice ports of the MP.
|
|
This object indicates the Source Port within the Slot of the Analog Voice Card,
|
|
we want to compress.
|
|
exPrt1 - exPrt16 = 1 - 16
|
|
noConnect=100 - when prtExVcPbxTsCvServiceSlot=noConnect."
|
|
::= {prtExVcPbxTsEntry 13}
|
|
|
|
-- The following tables contains information specific to
|
|
-- the isdn access modules
|
|
|
|
prtIsdnCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtIsdnCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the table objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtIsdnCnfg 1}
|
|
|
|
prtIsdnCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtIsdnCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtIsdnCnfgIdx, prtIsdnSltIdx, prtIsdnPrtIdx}
|
|
::= { prtIsdnCnfgTable 1}
|
|
|
|
PrtIsdnCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtIsdnCnfgIdx Integer32,
|
|
prtIsdnSltIdx INTEGER,
|
|
prtIsdnPrtIdx Integer32,
|
|
prtIsdnConnect INTEGER,
|
|
prtIsdnSignalingProtocol INTEGER,
|
|
prtIsdnBasicRateLineTopology INTEGER,
|
|
prtIsdnMode INTEGER,
|
|
prtIsdnFilter INTEGER,
|
|
prtIsdnSimultaneousCall INTEGER,
|
|
prtIsdnNumOfAbstractTerm Integer32,
|
|
prtIsdnSwitchMode INTEGER,
|
|
prtIsdnAbSide INTEGER,
|
|
prtIsdnQsigRole INTEGER,
|
|
prtIsdnInterface INTEGER,
|
|
prtIsdnCallMode INTEGER,
|
|
prtIsdnCallBackTimeout Integer32
|
|
}
|
|
|
|
prtIsdnCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtIsdnCnfgEntry 1}
|
|
|
|
prtIsdnSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10(14),
|
|
io11(15),
|
|
io12(16),
|
|
kmxMlA (103),
|
|
kmxMlB (104),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In the ?004 Unit the entries io6(10)..io12(16) are not valid
|
|
For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
|
|
::= { prtIsdnCnfgEntry 2}
|
|
|
|
prtIsdnPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
For MAXcess the values will be:
|
|
exPrt1(1),
|
|
exPrt2(2),
|
|
exPrt3(3),
|
|
exPrt4(4),
|
|
For KM-2100 the port index is calculated as follows:
|
|
100*Slot+Ch"
|
|
::= { prtIsdnCnfgEntry 3}
|
|
|
|
prtIsdnConnect OBJECT-TYPE
|
|
SYNTAX INTEGER { no(2), yes(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates if the port is connected."
|
|
::= { prtIsdnCnfgEntry 4 }
|
|
|
|
prtIsdnSignalingProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1), etsi(3), ess4(5), ess5(6), dms100(7),
|
|
ni1(9), ni2(10), ins64(17), ins1500(18), qsig(21),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute fixes which signaling protocol
|
|
is used at this port (D-Channel).
|
|
It is equivalent to isdnSignalingProtocol
|
|
in the isdn MIB."
|
|
DEFVAL { etsi }
|
|
::= { prtIsdnCnfgEntry 5 }
|
|
|
|
prtIsdnBasicRateLineTopology OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
pointToPoint(1),
|
|
pointToMultipoint(2),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is relevant for ISDN BRI only.
|
|
It is equivalent to isdnBasicRateLineTopology
|
|
in the isdn MIB."
|
|
::= { prtIsdnCnfgEntry 6 }
|
|
|
|
prtIsdnMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dialup(1),
|
|
leased(2),
|
|
syncLeased(3),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute allows the user to configure the port as
|
|
leased(2) in case of connection to a TDM network."
|
|
::= { prtIsdnCnfgEntry 7}
|
|
|
|
prtIsdnFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ notApplicable(1),
|
|
answerAll(2),
|
|
rejectAll(3),
|
|
selective(4),
|
|
callBack (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute allows the user to configure the port:
|
|
answerAll(2): accept all incoming calls,
|
|
rejectAll(3): reject all incoming calls,
|
|
selective(4): accept or reject according directory table.
|
|
callBack (5): In this mode the ISDN Ch will reject incoming calls
|
|
and will initiate call back to the rejected phone number."
|
|
::= { prtIsdnCnfgEntry 8}
|
|
|
|
prtIsdnSimultaneousCall OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{ notApplicable(1),
|
|
accept(2), reject(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In case of simultaneous call (local,remote and remote,local):
|
|
accept(2): accept the incoming call,
|
|
reject(3): reject the incoming call."
|
|
::= { prtIsdnCnfgEntry 9}
|
|
|
|
prtIsdnNumOfAbstractTerm OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An object for KM2100/4 agents.
|
|
255=Not Applicable
|
|
When ISDN Standard = ETSI or NTT (European) the value should be 255 (NotApplicable)
|
|
else If ML speed is 64Kbps value should be 1.
|
|
If ML speed is 128Kbps value can be either 1 or 2 (user selection)."
|
|
::= { prtIsdnCnfgEntry 10}
|
|
|
|
prtIsdnSwitchMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
auto (2),
|
|
manual (3),
|
|
connect(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For KM2100.
|
|
auto - The call is initiated automatically by one of the IO cards connected
|
|
to KML.10(ISDN card) having ISDN Switch Mode.
|
|
manual - The call is initiated by the user manually, for KML.10
|
|
having ISDN Switch Mode (via mdlSCmd).
|
|
connect- The call is initiated 'immediately', for KML.10 having ISDN Switch Mode.
|
|
'immediately'- means: immediately after power-up (when product performed
|
|
Reset) OR, since this value appears in the active
|
|
configuration.
|
|
In this case, the call can be disconnected only by power-off of the
|
|
product or by changing this object to another value (or actual Remove
|
|
of the KML.10 relevant card).
|
|
notApplicable - For other card types."
|
|
::= { prtIsdnCnfgEntry 11}
|
|
|
|
prtIsdnAbSide OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
aSide (2),
|
|
bSide (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates the QSIG side in layer 3.
|
|
This definition is from the QSIG Standard."
|
|
::= { prtIsdnCnfgEntry 12}
|
|
|
|
prtIsdnQsigRole OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
slave (2),
|
|
master (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates the QSIG side in layer 1 & 2."
|
|
::= { prtIsdnCnfgEntry 13}
|
|
|
|
prtIsdnInterface OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
lt (1),
|
|
nt (2),
|
|
te (3),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"It indicates the interface type:
|
|
lt = line termination
|
|
nt = network termination
|
|
te = terminal equipment."
|
|
::= { prtIsdnCnfgEntry 14}
|
|
|
|
prtIsdnCallMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
initiate (2),
|
|
listen (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the acceptance of incoming calls.
|
|
Initiate - Callout
|
|
Listen - Callin. "
|
|
::= { prtIsdnCnfgEntry 15}
|
|
|
|
|
|
prtIsdnCallBackTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only if 'prtIsdnFilter' is 'CallBack'
|
|
and determines how long to wait from receiving the incoming call
|
|
until initiating the call back call.
|
|
The vaules range should be '1..20 sec' and the default 10 sec."
|
|
::= { prtIsdnCnfgEntry 16}
|
|
|
|
|
|
|
|
prtIsdnEndpointTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtIsdnEndpointEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the table objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtIsdnCnfg 2}
|
|
|
|
prtIsdnEndpointEntry OBJECT-TYPE
|
|
SYNTAX PrtIsdnEndpointEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtIsdnEndpointCnfgIdx, prtIsdnEndpointSltIdx,
|
|
prtIsdnEndpointPrtIdx, prtIsdnEndpointIdx }
|
|
::= { prtIsdnEndpointTable 1}
|
|
|
|
PrtIsdnEndpointEntry ::=
|
|
SEQUENCE {
|
|
prtIsdnEndpointCnfgIdx Integer32,
|
|
prtIsdnEndpointSltIdx INTEGER,
|
|
prtIsdnEndpointPrtIdx Integer32,
|
|
prtIsdnEndpointIdx INTEGER,
|
|
prtIsdnEndpointTeiType INTEGER,
|
|
prtIsdnEndpointTeiValue Integer32,
|
|
prtIsdnEndpointSpid DisplayString,
|
|
prtIsdnEndpointBearerCh INTEGER,
|
|
prtIsdnEndpointRowStatus RowStatus
|
|
}
|
|
|
|
prtIsdnEndpointCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtIsdnEndpointEntry 1}
|
|
|
|
prtIsdnEndpointSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1(5),
|
|
io2(6),
|
|
io3(7),
|
|
io4(8),
|
|
io5(9),
|
|
io6(10),
|
|
io7(11),
|
|
io8(12),
|
|
io9(13),
|
|
io10(14),
|
|
io11(15),
|
|
io12(16),
|
|
kmxMlA (103),
|
|
kmxMlB (104),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
In ?004 Unit the entries io6(10)..io12(16) are not valid
|
|
For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
|
|
::= { prtIsdnEndpointEntry 2}
|
|
|
|
prtIsdnEndpointPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
For MAXcess the values will be:
|
|
exPrt1(1),
|
|
exPrt2(2),
|
|
exPrt3(3),
|
|
exPrt4(4),
|
|
For KM-2100 the port index is calculated as follows:
|
|
100*Slot+Ch"
|
|
::= { prtIsdnEndpointEntry 3}
|
|
|
|
prtIsdnEndpointIdx OBJECT-TYPE
|
|
SYNTAX INTEGER { atei1(1), atei2(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Since more than one endpoint may be defined per
|
|
isdn entity, this field is a simple index.
|
|
It corresponds to isdnEndpointIdx in the isdn MIB."
|
|
-- DEFVAL { atei1 }
|
|
::= { prtIsdnEndpointEntry 4}
|
|
|
|
prtIsdnEndpointTeiType OBJECT-TYPE
|
|
SYNTAX INTEGER { dynamic(1), static(2), notApplicable(255) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of TEI (Terminal Endpoint Identifier)
|
|
used for this Terminal Endpoint. In case of dynamic(1),
|
|
the TEI value is selected by the switch. In
|
|
case of static(2), a valid TEI value has to be
|
|
entered in the isdnEndpointTeiValue object.
|
|
interface type as well as the Terminal Endpoint type.
|
|
static(2). On Basic Rate interfaces the default value
|
|
is dynamic(1) for isdn(63) Terminal Endpoints.
|
|
It corresponds to isdnEndpointTeiType in the isdn MIB."
|
|
::= { prtIsdnEndpointEntry 5}
|
|
|
|
prtIsdnEndpointTeiValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the TEI Type is static, the value of the TEI should be
|
|
between 0 and 63. Else, it is not selectable by user.
|
|
255 = notApplicable.
|
|
It corresponds to isdnEndpointTeiValue in the isdn MIB"
|
|
::= { prtIsdnEndpointEntry 6 }
|
|
|
|
prtIsdnEndpointSpid OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Service profile IDentifier (SPID) information
|
|
for this Terminal Endpoint. It is is composed of
|
|
9-20 numeric characters.
|
|
It corresponds to isdnEndpointSpid in the isdn MIB."
|
|
::= { prtIsdnEndpointEntry 7 }
|
|
|
|
prtIsdnEndpointBearerCh OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
anyChannel (2),
|
|
channelB1 (3),
|
|
channelB2 (4) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the selected dialing channel.
|
|
anyChannel - the system selects the dialing channel."
|
|
::= { prtIsdnEndpointEntry 8}
|
|
|
|
prtIsdnEndpointRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field indicates whether to consider this endpoint or not.
|
|
The only possible supported RowStatus vaules are
|
|
active (1) and destroy (6)."
|
|
::= { prtIsdnEndpointEntry 9}
|
|
|
|
prtIsdnDirectoryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtIsdnDirectoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the table objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= { prtIsdnCnfg 3}
|
|
|
|
prtIsdnDirectoryEntry OBJECT-TYPE
|
|
SYNTAX PrtIsdnDirectoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtIsdnDirectoryCnfgIdx, prtIsdnDirectorySltIdx, prtIsdnDirectoryPrtIdx }
|
|
::= { prtIsdnDirectoryTable 1}
|
|
|
|
PrtIsdnDirectoryEntry ::=
|
|
SEQUENCE {
|
|
prtIsdnDirectoryCnfgIdx Integer32,
|
|
prtIsdnDirectorySltIdx INTEGER,
|
|
prtIsdnDirectoryPrtIdx Integer32,
|
|
prtIsdnDirectoryLocalAddr DisplayString,
|
|
prtIsdnDirectoryLocalSubAddr DisplayString,
|
|
prtIsdnDirectoryRemoteAddr DisplayString,
|
|
prtIsdnDirectoryRemoteSubAddr DisplayString,
|
|
prtIsdnDirectoryPrtNu Integer32,
|
|
prtIsdnDirectoryTeiId Integer32,
|
|
prtIsdnDirectoryRowStatus RowStatus,
|
|
prtIsdnDirectoryLocalAddr2 DisplayString,
|
|
prtIsdnDirectoryLocalSubAddr2 DisplayString,
|
|
prtIsdnDirectoryRemoteAddr2 DisplayString,
|
|
prtIsdnDirectoryRemoteSubAddr2 DisplayString
|
|
}
|
|
|
|
prtIsdnDirectoryCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtIsdnDirectoryEntry 1}
|
|
|
|
prtIsdnDirectorySltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1(5),
|
|
io2(6),
|
|
io3(7),
|
|
io4(8),
|
|
io5(9),
|
|
io6(10),
|
|
io7(11),
|
|
io8(12),
|
|
io9(13),
|
|
io10(14),
|
|
io11(15),
|
|
io12(16),
|
|
kmxMlA (103),
|
|
kmxMlB (104),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the card is inserted.
|
|
For MX300/30 ports:
|
|
io1(5) = isdn1(5) and io2(6) = isdn2(6).
|
|
In ?004 Unit the entries io6(10)..io12(16) are not valid
|
|
For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
|
|
::= { prtIsdnDirectoryEntry 2}
|
|
|
|
prtIsdnDirectoryPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For MAXcess this is the internal port number: 101, 102,....
|
|
For KM-2100 the port index is calculated as follows:
|
|
100*Slot+Ch"
|
|
::= { prtIsdnDirectoryEntry 3}
|
|
|
|
prtIsdnDirectoryLocalAddr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(17..20))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the local address associated with this
|
|
entry.
|
|
- For MX: Size=17 , Default=0 (17 characters)
|
|
- For KM: Size=20, Default=blank (20 characters) "
|
|
::= { prtIsdnDirectoryEntry 4}
|
|
|
|
prtIsdnDirectoryLocalSubAddr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(4..6))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the local subaddress associated with this
|
|
entry.
|
|
- For MX: Size=6 , Default=0 (6 characters)
|
|
- For KM: Size=4 , Default=blank (4 characters)"
|
|
::= { prtIsdnDirectoryEntry 5}
|
|
|
|
prtIsdnDirectoryRemoteAddr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(17..20))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the remote address associated with this
|
|
entry.
|
|
- For MX: Size=17 , Default=0 (17 characters)
|
|
- For KM: Size=20, Default=blank (20 characters)"
|
|
::= { prtIsdnDirectoryEntry 6}
|
|
|
|
prtIsdnDirectoryRemoteSubAddr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(4..6))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the remote subaddress associated with this
|
|
entry.
|
|
- For MX: Size=6 , Default=0 (6 characters)
|
|
- For KM: Size=4 , Default=blank (4 characters)"
|
|
::= { prtIsdnDirectoryEntry 7}
|
|
|
|
|
|
prtIsdnDirectoryPrtNu OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the external port number connected to
|
|
this entry."
|
|
DEFVAL { 1 }
|
|
::= { prtIsdnDirectoryEntry 8}
|
|
|
|
prtIsdnDirectoryTeiId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the abstract terminal id if relevant,
|
|
connected to this entry."
|
|
DEFVAL { 1 }
|
|
::= { prtIsdnDirectoryEntry 9}
|
|
|
|
prtIsdnDirectoryRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the status for the row. It allows to know
|
|
whether to consider this row or not.
|
|
The only possible supported RowStatus vaules are
|
|
active (1) and destroy (6)."
|
|
::= { prtIsdnDirectoryEntry 10}
|
|
|
|
prtIsdnDirectoryLocalAddr2 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(17..20))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the second local address associated with this
|
|
entry.
|
|
- For MX: Size=17 , Default=0 (17 characters)
|
|
- For KM: Size=20, Default=blank (20 characters)"
|
|
::= { prtIsdnDirectoryEntry 11}
|
|
|
|
prtIsdnDirectoryLocalSubAddr2 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(4..6))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the second local subaddress associated with this
|
|
entry.
|
|
- For MX: Size=6 , Default=0 (6 characters)
|
|
- For KM: Size=4 , Default=blank (4 characters)"
|
|
::= { prtIsdnDirectoryEntry 12}
|
|
|
|
prtIsdnDirectoryRemoteAddr2 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(17..20))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the second remote address associated with this
|
|
entry.
|
|
- For MX: Size=17 , Default=0 (17 characters)
|
|
- For KM: Size=20, Default=blank(20 characters) "
|
|
::= { prtIsdnDirectoryEntry 13}
|
|
|
|
prtIsdnDirectoryRemoteSubAddr2 OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(4..6))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the second remote subaddress associated with this
|
|
entry.
|
|
- For MX: Size=6 , Default=0 (6 characters)
|
|
- For KM: Size=4 , Default=blank (4 characters) "
|
|
::= { prtIsdnDirectoryEntry 14}
|
|
|
|
|
|
|
|
-- This table is an extension for new version of MAXcess
|
|
-- modules.
|
|
prtFrPlusCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtFrPlusCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry."
|
|
::= {prtFrPlusCnfg 1}
|
|
|
|
prtFrPlusCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtFrPlusCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtFrPlusCnfgIdx, prtFrPlusSltIdx, prtFrPlusPrtIdx }
|
|
::= { prtFrPlusCnfgTable 1}
|
|
|
|
PrtFrPlusCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtFrPlusCnfgIdx Integer32,
|
|
prtFrPlusSltIdx INTEGER,
|
|
prtFrPlusPrtIdx Integer32,
|
|
prtFrPlusNotSegmentedPriorities OCTET STRING
|
|
}
|
|
|
|
prtFrPlusCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. "
|
|
::= { prtFrPlusCnfgEntry 1}
|
|
|
|
prtFrPlusSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot Index.
|
|
For ISDN BRI Ports of MX300/30,
|
|
io1(5) = isdn1(5) and io2(6) = isdn2(6)."
|
|
::= { prtFrPlusCnfgEntry 2}
|
|
|
|
prtFrPlusPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
This port number should be:
|
|
- for ISDN cards: inPrt1(101)->inPrt50(150)
|
|
- for MHS1 card : exPrt1(1)
|
|
- for MHS3, MLS3 cards: exPrt1(1)->exPrt3(3)
|
|
- for MLS6 cards: exPrt1(1)->exPrt6(6)."
|
|
::= { prtFrPlusCnfgEntry 3}
|
|
|
|
prtFrPlusNotSegmentedPriorities OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(1))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter is relevant only for FR+ protocol and
|
|
asks the MXcess NOT to segment data with specified
|
|
priorities: from LSB:
|
|
bit 1 is for priority 1,
|
|
bit 2 is for priority 2, .... till bit 7 for priority 7.
|
|
- a priority selected to be segmented : its bit will be '0'
|
|
- a priority not to be segmented : its bit will be '1'
|
|
Default is 00000000; i.e, segment all priorities."
|
|
DEFVAL { '00'H }
|
|
::= { prtFrPlusCnfgEntry 4 }
|
|
|
|
|
|
-- This table is an extension of prtExPh1MlCnfgTable for MTML cards
|
|
-- of MP-2200 and MP-2100
|
|
|
|
prtMl4CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtMl4CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is an extension table for MTML-4 card parameters."
|
|
::= {prtMl4Cnfg 1}
|
|
|
|
prtMl4CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtMl4CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtMl4CnfgIdx, prtMl4SltIdx, prtMl4PrtIdx }
|
|
::= { prtMl4CnfgTable 1}
|
|
|
|
PrtMl4CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtMl4CnfgIdx Integer32,
|
|
prtMl4SltIdx INTEGER,
|
|
prtMl4PrtIdx INTEGER,
|
|
prtMl4SigProfile INTEGER,
|
|
prtMl4CGA INTEGER,
|
|
prtMl4Oos INTEGER,
|
|
prtMl4VoiceOos OCTET STRING,
|
|
prtMl4DataOos OCTET STRING,
|
|
prtMl4Service INTEGER,
|
|
prtMl4IpAddress IpAddress,
|
|
prtMl4IpMask IpAddress,
|
|
prtMl4SignalingMode INTEGER,
|
|
prtMl4EchoCanceler INTEGER,
|
|
prtMl4OosErrorSource INTEGER,
|
|
prtMl4OosEntryThreshold Integer32,
|
|
prtMl4OosExitThreshold Integer32,
|
|
prtMl4LogicalLinkId Integer32,
|
|
prtMl4DedicatedTs Integer32,
|
|
prtMl4RemCrc INTEGER,
|
|
prtMl4CrossConnectLevel INTEGER,
|
|
prtMl4PppEchoFailDetection INTEGER,
|
|
prtMl4EcanCasControl INTEGER
|
|
}
|
|
|
|
|
|
prtMl4CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. The write operation is valid only
|
|
to the TmpCnfg."
|
|
::= { prtMl4CnfgEntry 1}
|
|
|
|
prtMl4SltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the module is inserted."
|
|
::= { prtMl4CnfgEntry 2}
|
|
|
|
prtMl4PrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
exPrt3 (3),
|
|
exPrt4 (4),
|
|
exPrt5 (5),
|
|
exPrt6 (6),
|
|
exPrt7 (7),
|
|
exPrt8 (8),
|
|
inPrt1 (101),
|
|
inPrt2 (102),
|
|
inPrt3 (103),
|
|
inPrt4 (104),
|
|
inPrt5 (105),
|
|
inPrt6 (106),
|
|
inPrt7 (107),
|
|
inPrt8 (108),
|
|
inPrt9 (109),
|
|
inPrt10 (110),
|
|
inPrt11 (111),
|
|
inPrt12 (112),
|
|
inPrt13 (113),
|
|
inPrt14 (114),
|
|
inPrt15 (115),
|
|
inPrt16 (116),
|
|
inPrt17 (117),
|
|
inPrt18 (118),
|
|
inPrt19 (119),
|
|
inPrt20 (120),
|
|
inPrt21 (121),
|
|
inPrt22 (122),
|
|
inPrt23 (123),
|
|
inPrt24 (124),
|
|
inPrt25 (125),
|
|
inPrt26 (126),
|
|
inPrt27 (127),
|
|
inPrt28 (128),
|
|
inPrt29 (129),
|
|
inPrt30 (130),
|
|
inPrt31 (131),
|
|
inPrt32 (132),
|
|
inPrt33 (133),
|
|
inPrt34 (134),
|
|
inPrt35 (135),
|
|
inPrt36 (136),
|
|
inPrt37 (137),
|
|
inPrt38 (138),
|
|
inPrt39 (139),
|
|
inPrt40 (140),
|
|
inPrt41 (141),
|
|
inPrt42 (142),
|
|
inPrt43 (143),
|
|
inPrt44 (144),
|
|
inPrt45 (145),
|
|
inPrt46 (146),
|
|
inPrt47 (147),
|
|
inPrt48 (148),
|
|
inPrt49 (149),
|
|
inPrt50 (150),
|
|
inPrt51 (151),
|
|
inPrt52 (152),
|
|
inPrt53 (153),
|
|
inPrt54 (154),
|
|
inPrt55 (155),
|
|
inPrt56 (156),
|
|
inPrt57 (157),
|
|
inPrt58 (158),
|
|
inPrt59 (159),
|
|
inPrt60 (160),
|
|
inPrt61 (161),
|
|
inPrt62 (162),
|
|
inPrt63 (163),
|
|
inPrt64 (164),
|
|
inPrt65 (165),
|
|
inPrt66 (166),
|
|
inPrt67 (167),
|
|
inPrt68 (168),
|
|
inPrt69 (169),
|
|
inPrt70 (170),
|
|
inPrt71 (171),
|
|
inPrt72 (172),
|
|
inPrt73 (173),
|
|
inPrt74 (174),
|
|
inPrt75 (175),
|
|
inPrt76 (176),
|
|
inPrt77 (177),
|
|
inPrt78 (178),
|
|
inPrt79 (179),
|
|
inPrt80 (180),
|
|
inPrt81 (181),
|
|
inPrt82 (182),
|
|
inPrt83 (183),
|
|
inPrt84 (184)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number."
|
|
::= { prtMl4CnfgEntry 3}
|
|
|
|
prtMl4SigProfile OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
p1 (3),
|
|
p2 (4),
|
|
p3 (5),
|
|
p4 (6),
|
|
p5 (7),
|
|
perTS (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Signaling Profile of the port.
|
|
none - when the Frame is G732N (no MF) or Unframed.
|
|
p1 = profile 1
|
|
p2 = profile 2
|
|
p3 = profile 3
|
|
p4 = profile 4
|
|
p5 = profile 5
|
|
perTS = when Signaling Profile is selected per TS."
|
|
::= {prtMl4CnfgEntry 4}
|
|
|
|
prtMl4CGA OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
trans(2),
|
|
full (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object selects the method used to signal the CGA state
|
|
to the other end, through the main link.
|
|
'none' - non-transparent mode. When one of the links
|
|
(main) will be in Out Of Service state, both
|
|
'Data/Voice Oos' and 'Oos' will be
|
|
transmitted to the other end.
|
|
'trans' - when one of the links (main) will be in Out
|
|
Of Service state, 'Data/Voice Oos' will be
|
|
transmitted to the other end.
|
|
'full' - fully-transparent mode. When one of the links
|
|
(main) will be in Out Of Service state,
|
|
neither 'Data/Voice Oos' nor 'Oos' will
|
|
be transmitted to the other end."
|
|
::= { prtMl4CnfgEntry 5 }
|
|
|
|
prtMl4Oos OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notSupported (2),
|
|
forcedIdle (3),
|
|
forcedBusy (4),
|
|
busyIdle (5),
|
|
idleBusy (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"'idle' = '0' = on-hook, idle state
|
|
'busy' = '1' = off-hook, busy state
|
|
'forcedIdle' = SP = both A and B signaling bits are forced
|
|
to '0' during out-of-service periods.
|
|
'forcedBusy' = MK = both A and B signaling bits are forced
|
|
to '1' during out-of-service periods.
|
|
'busyIdle' = MK_SP = A and B bits are forced to '1' for
|
|
2.5 seconds; then they are switched to '0'
|
|
until out-of-service condition disappears.
|
|
'idleBusy' = SP_MK = A and B bits are forced to '0' for
|
|
2.5 seconds; then they are switched to '1'
|
|
until out-of-service condition disappears.
|
|
- for T1: '0'=0 ; '1'=1
|
|
- for E1: '0'=1 ; '1'=0 "
|
|
::= { prtMl4CnfgEntry 6 }
|
|
|
|
prtMl4VoiceOos OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voice Out-Of-Service code. Valid range: (0 - FF HEX).
|
|
For agents that do not support this feature, the value will
|
|
always be 0."
|
|
::= { prtMl4CnfgEntry 7 }
|
|
|
|
prtMl4DataOos OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data Out-Of-Service code. Valid range: (0 - FF HEX).
|
|
For agents that do not support this feature, the value will
|
|
always be 0."
|
|
::= { prtMl4CnfgEntry 8 }
|
|
|
|
prtMl4Service OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
leasedLine (2),
|
|
v51 (3),
|
|
v52Master (4),
|
|
v52Slave (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link Service.
|
|
leasedLine - usual TDM interface.
|
|
v51 - V5.1 interface.
|
|
v52Master - V5.2 Link to Local Exchange.
|
|
v52Slave - a ML that is transferred to the v52Master."
|
|
::= {prtMl4CnfgEntry 9}
|
|
|
|
prtMl4IpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address of the port."
|
|
::= {prtMl4CnfgEntry 10}
|
|
|
|
prtMl4IpMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP subnet mask of the port."
|
|
::= {prtMl4CnfgEntry 11}
|
|
|
|
prtMl4SignalingMode OBJECT-TYPE
|
|
SYNTAX INTEGER { notApplicable(1),
|
|
cas(2),
|
|
ccs(3),
|
|
robbedBit(4),
|
|
other (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Refers to the signaling mode of the port (or framer module).
|
|
notApplicable(1)- means that no framer is needed for this port (no signaling),
|
|
or that this object is not relevant.
|
|
cas(2) means Channel Associated Signaling. Used for E1 Links.
|
|
ccs(3) is the Common Channel Signaling (the signaling is not within
|
|
the channels time slot - a TS for signaling is used).
|
|
robbedBit(4) is a method implementing 7 bits for the voice and 1 bit
|
|
dedicated for signaling. Used for T1 Links.
|
|
other (5)- Signaling generally exists though not specifically according
|
|
to one of the values listed ; this port uses a framer in this case."
|
|
::= {prtMl4CnfgEntry 12}
|
|
|
|
prtMl4EchoCanceler OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Echo canceler activation."
|
|
::= {prtMl4CnfgEntry 13}
|
|
|
|
prtMl4OosErrorSource OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
framing (3),
|
|
bpv (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OOS (Out-of-Service) Error Source.
|
|
This object is applicable for T1 ports only."
|
|
::= {prtMl4CnfgEntry 14}
|
|
|
|
prtMl4OosEntryThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..999)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the number of Errors per Second that determine the
|
|
minimum unacceptable noise level. This value will be the Entry Threshold
|
|
to the OOS (Out-of-Service) state.
|
|
This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4).
|
|
0=notApplicable."
|
|
::= { prtMl4CnfgEntry 15}
|
|
|
|
prtMl4OosExitThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..99)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the number of consecutive Error-Free-Seconds before
|
|
going from OOS state to Normal state. This value will be the Exit Threshold
|
|
from the OOS (Out-of-Service) state.
|
|
Units=seconds
|
|
This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4).
|
|
0=notApplicable."
|
|
::= { prtMl4CnfgEntry 16}
|
|
|
|
prtMl4LogicalLinkId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..257)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines for a V5.2 Master ML the Logical Link Id.
|
|
Valid values are: 0..256.
|
|
NA=257."
|
|
::= { prtMl4CnfgEntry 17}
|
|
|
|
prtMl4DedicatedTs OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify Dedicated TS of the E1 port (V5.2).
|
|
It is applicable only when prtMl4Service=v52Slave and
|
|
prtExPh1MlInbandMng selected is dedicatedTs, dedicatedPpp or dedicatedFr.
|
|
1..31 - Dedicated TS of E1
|
|
255 - notApplicable
|
|
Other values are invalid."
|
|
::= { prtMl4CnfgEntry 18}
|
|
|
|
prtMl4RemCrc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the E1 of the Remote device
|
|
connected to this E1 port, will have CRC-4 or not."
|
|
::= { prtMl4CnfgEntry 19 }
|
|
|
|
prtMl4CrossConnectLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
ds0 (2),
|
|
ds1 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the cross connect is
|
|
on DS1 or DS0 (time-slots) level.
|
|
When cross connect level is ds1, Destination Slot
|
|
is indicated by prtGenCnfgLinkToSlot,
|
|
Destination Port is indicated by prtGenCnfgLinkToPort.
|
|
For Unframed Line Type, cross connect level can be either
|
|
notApplicable (NC=not connected) or DS1.
|
|
Otherwise, default value is ds0."
|
|
::= { prtMl4CnfgEntry 20 }
|
|
|
|
prtMl4PppEchoFailDetection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the PPP Echo is taken into account
|
|
for its Fail Detection.
|
|
This object is relevant when Inband Mng between devices is Dedicated TS PPP.
|
|
Default=Disable.
|
|
Enable - will be selected mainly when a T1/E1 Ring exists and between 2 adjacent
|
|
Ring devices there is another device or Net, that causes these Ring devices
|
|
not to sense that the PPP connection between them is lost. In this case,
|
|
Echo Request should be initiated by the port."
|
|
::= { prtMl4CnfgEntry 21 }
|
|
|
|
prtMl4EcanCasControl OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables/disables ECAN (Echo Canceller) control activation/deactivation
|
|
sent via the A, B, C, D multiframe signaling BITs."
|
|
::= { prtMl4CnfgEntry 22 }
|
|
|
|
|
|
--prtAcmCnfgTable defines the parameters of the
|
|
--ACM cards family external ports 1-8
|
|
|
|
prtAcmCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtAcmCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a table for ACM port parameters."
|
|
::= {prtAcmCnfg 1}
|
|
|
|
prtAcmCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtAcmCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtAcmCnfgIdx, prtAcmSltIdx, prtAcmPrtIdx }
|
|
::= { prtAcmCnfgTable 1}
|
|
|
|
PrtAcmCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtAcmCnfgIdx Integer32,
|
|
prtAcmSltIdx INTEGER,
|
|
prtAcmPrtIdx INTEGER,
|
|
prtAcmConnect INTEGER,
|
|
prtAcmActiveState INTEGER,
|
|
prtAcmAlrString DisplayString
|
|
}
|
|
|
|
prtAcmCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. The write operation is valid only
|
|
to the TmpCnfg."
|
|
::= { prtAcmCnfgEntry 1}
|
|
|
|
prtAcmSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the module is inserted."
|
|
::= { prtAcmCnfgEntry 2}
|
|
|
|
prtAcmPrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2),
|
|
exPrt3 (3),
|
|
exPrt4 (4),
|
|
exPrt5 (5),
|
|
exPrt6 (6),
|
|
exPrt7 (7),
|
|
exPrt8 (8) ,
|
|
exPrt9 (9) ,
|
|
exPrt10 (10) ,
|
|
exPrt11 (11) ,
|
|
exPrt12 (12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number."
|
|
::= { prtAcmCnfgEntry 3}
|
|
|
|
prtAcmConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
connected or not. Only a connected port can perform activity."
|
|
::= {prtAcmCnfgEntry 4}
|
|
|
|
prtAcmActiveState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
low (2),
|
|
high (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Electric Active State of the port."
|
|
::= {prtAcmCnfgEntry 5}
|
|
|
|
prtAcmAlrString OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..35))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm string selected by user for the Inbound ports.
|
|
This object is applicable only for the Inbound Ports: ext-5..ext-12.
|
|
For the Outbound Ports (ext-1..ext-4), the size of this string will be 0."
|
|
::= {prtAcmCnfgEntry 6}
|
|
|
|
--prtE2CnfgTable defines the parameters of the
|
|
--E2 card ports
|
|
|
|
prtE2CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtE2CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a table for E2 port parameters."
|
|
::= {prtE2Cnfg 1}
|
|
|
|
prtE2CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtE2CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtE2CnfgIdx, prtE2SltIdx, prtE2PrtIdx }
|
|
::= { prtE2CnfgTable 1}
|
|
|
|
PrtE2CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtE2CnfgIdx Integer32,
|
|
prtE2SltIdx INTEGER,
|
|
prtE2PrtIdx INTEGER,
|
|
prtE2Connect INTEGER,
|
|
prtE2MngOnNationalBit INTEGER
|
|
}
|
|
|
|
prtE2CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. The write operation is valid only
|
|
to the TmpCnfg."
|
|
::= { prtE2CnfgEntry 1}
|
|
|
|
prtE2SltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the module is inserted."
|
|
::= { prtE2CnfgEntry 2}
|
|
|
|
prtE2PrtIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
exPrt1 (1),
|
|
exPrt2 (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number."
|
|
::= { prtE2CnfgEntry 3}
|
|
|
|
prtE2Connect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether the port should be
|
|
connected or not. Only a connected port can perform activity."
|
|
::= {prtE2CnfgEntry 4}
|
|
|
|
prtE2MngOnNationalBit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates whether National Bit will be used for
|
|
Management or not."
|
|
::= {prtE2CnfgEntry 5}
|
|
|
|
--prtLanWanCnfgTable defines the parameters of the Lan-Wan ports
|
|
--(for HS-ETUB MP card)
|
|
|
|
prtLanWanCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtLanWanCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a table for Lan-Wan port parameters."
|
|
::= {prtLanWanCnfg 1}
|
|
|
|
prtLanWanCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtLanWanCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtLanWanCnfgIdx, prtLanWanSltIdx, prtLanWanPrtIdx }
|
|
::= { prtLanWanCnfgTable 1}
|
|
|
|
PrtLanWanCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtLanWanCnfgIdx Integer32,
|
|
prtLanWanSltIdx INTEGER,
|
|
prtLanWanPrtIdx Integer32,
|
|
prtLanWanMode INTEGER,
|
|
prtLanWanDestIf Integer32,
|
|
prtLanWanEgressVlanMode INTEGER,
|
|
prtLanWanL2Protocol INTEGER,
|
|
prtLanWanStpPriority Integer32,
|
|
prtLanWanStpCost Integer32,
|
|
prtLanWanToLanVlanMode INTEGER,
|
|
prtLanWanVlanId Integer32,
|
|
prtLanWanVlanPriority Integer32,
|
|
prtLanWanMtu Integer32,
|
|
prtLanWanVlanType INTEGER
|
|
}
|
|
|
|
prtLanWanCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg. The write operation is valid only
|
|
to the TmpCnfg."
|
|
::= {prtLanWanCnfgEntry 1}
|
|
|
|
prtLanWanSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique slot position where the module is inserted."
|
|
::= {prtLanWanCnfgEntry 2}
|
|
|
|
prtLanWanPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique number to identify a port
|
|
in a specific card.
|
|
Generally, for MP-210X/2200, the Port Index will be according to the
|
|
external/internal port number:
|
|
- exPrtX : X
|
|
- inPrtX : 100 + X
|
|
For FCD-155, refer to device specification"
|
|
::= {prtLanWanCnfgEntry 3}
|
|
|
|
prtLanWanMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
bridge (2),
|
|
bridgeAndStp (3),
|
|
layer3SubnetSwitch(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the working mode of this port.
|
|
For FCD155, layer3SubnetSwitch is not applicable"
|
|
::= {prtLanWanCnfgEntry 4}
|
|
|
|
prtLanWanDestIf OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the Destination Interface for the frames
|
|
received by this port.
|
|
- Switching Table = 100 (it means that the destination interface
|
|
will be determined by the Switching Table)
|
|
- inPrtX (internal-X port): 100 + X .
|
|
For FCD-155 this object is not applicable =0 "
|
|
::= {prtLanWanCnfgEntry 5}
|
|
|
|
prtLanWanEgressVlanMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
unmodified (2),
|
|
tag (3),
|
|
doubleTag (4),
|
|
untag (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines what to do with the VLAN frames that exit
|
|
via the WAN side of the port.
|
|
This object is not applicable when prtLanWanMode=l3SubnetSwitch(4)."
|
|
::= {prtLanWanCnfgEntry 6}
|
|
|
|
prtLanWanL2Protocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
ppp (3),
|
|
hdlc (4),
|
|
pppoHdlc (5),
|
|
mlppp (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"L2 Protocol.
|
|
When prtLanWanMode=l3SubnetSwitch(4), the only valid value is ppp(3)."
|
|
::= {prtLanWanCnfgEntry 7}
|
|
|
|
prtLanWanStpPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the priority field which is contained in the first
|
|
(in network byte order) octet of the (2 octet long) Port ID."
|
|
::= {prtLanWanCnfgEntry 8}
|
|
|
|
prtLanWanStpCost OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The contribution of this port to the path cost of paths towards
|
|
the spanning tree root which include this port. 802.1D-1990 recommends
|
|
that the default value of this parameter be in inverse proportion
|
|
to the speed of the attached LAN."
|
|
::= {prtLanWanCnfgEntry 9}
|
|
|
|
prtLanWanToLanVlanMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
unmodified (2),
|
|
tag (3),
|
|
doubleTag (4),
|
|
untag (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines what to do with the VLAN frames that come from
|
|
WAN side of the port and exit towards one of the LAN ports.
|
|
This object is applicable only when prtLanWanDestIf=100 or 101
|
|
(Switching Table or inPrt1)."
|
|
::= {prtLanWanCnfgEntry 10}
|
|
|
|
prtLanWanVlanId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..4095)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the VLAN Id attached to a frame, when the relevant
|
|
Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is
|
|
tag or doubleTag.
|
|
0=not applicable."
|
|
::= {prtLanWanCnfgEntry 11}
|
|
|
|
prtLanWanVlanPriority OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the VLAN Priority attached to a frame, when the relevant
|
|
Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is
|
|
tag or doubleTag.
|
|
Valid values: 0..7
|
|
255=not applicable."
|
|
::= {prtLanWanCnfgEntry 12}
|
|
|
|
prtLanWanMtu OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The size of the largest packet which can be sent/received on the interface,
|
|
specified in octets.
|
|
Valid values change per device.
|
|
0=not applicable."
|
|
::= {prtLanWanCnfgEntry 13}
|
|
|
|
prtLanWanVlanType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
portBasedVlan (2),
|
|
ieee802dot1q (3),
|
|
ieee802dot1qTaggedOnly (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This oject indicates type of VLAN this port is assigned to.
|
|
Port Base Vlan parameters are defined by objects under
|
|
radBridgePortBaseVlan"
|
|
::= { prtLanWanCnfgEntry 14}
|
|
|
|
--
|
|
-- The following table includes the IP addresses of all the NMS to which
|
|
-- Traps will be sent
|
|
--
|
|
|
|
--mngTrapIpTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF MngTrapIpEntry
|
|
-- MAX-ACCESS not-accessible
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This table indicates the destination address of the traps.
|
|
-- Internally it will be limited to ten addresses. "
|
|
-- ::= { agnt 7 }
|
|
--
|
|
--mngTrapIpEntry OBJECT-TYPE
|
|
-- SYNTAX MngTrapIpEntry
|
|
-- MAX-ACCESS not-accessible
|
|
-- STATUS current
|
|
-- INDEX { mngTrapIpIdx }
|
|
-- ::= { mngTrapIpTable 1 }
|
|
--
|
|
--MngTrapIpEntry ::=
|
|
-- SEQUENCE {
|
|
-- mngTrapIpIdx Integer32,
|
|
-- mngTrapIpIP IpAddress,
|
|
-- mngTrapIpIPMask IpAddress
|
|
-- }
|
|
--
|
|
--mngTrapIpIdx OBJECT-TYPE
|
|
-- SYNTAX Integer32
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- " This value indicates an index of a specific IP address"
|
|
-- ::= { mngTrapIpEntry 1 }
|
|
--
|
|
--mngTrapIpIP OBJECT-TYPE
|
|
-- SYNTAX IpAddress
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This value indicates the destination addresses of the traps. "
|
|
-- ::= { mngTrapIpEntry 2 }
|
|
--
|
|
--mngTrapIpIPMask OBJECT-TYPE
|
|
-- SYNTAX IpAddress
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This value indicates the mask of the destination addresses of the traps. "
|
|
-- ::= { mngTrapIpEntry 3 }
|
|
--
|
|
--
|
|
-- Traps
|
|
|
|
--NOTIFICATIONS
|
|
|
|
muxHubEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The events for ."
|
|
::= { muxHub 0 }
|
|
|
|
alarmsTrap NOTIFICATION-TYPE
|
|
OBJECTS { alrBufDescription }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent whenever alarm occurs in the agent."
|
|
::= { muxHubEvents 1 }
|
|
|
|
sanityTrap NOTIFICATION-TYPE
|
|
OBJECTS { agnSSanityCheckStatus, agnCSaveCnfgIdxCmd }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent after a data base update.
|
|
It returns the sanity result status and the configuration no.
|
|
checked.
|
|
If the result is of Flip DB Sanity Check, the configuration
|
|
no. sent will be 0.
|
|
If the result is of Variant Sanity Check, the configuration
|
|
no. sent will be 100."
|
|
::= { muxHubEvents 2 }
|
|
|
|
cnfgFlipTrap NOTIFICATION-TYPE
|
|
OBJECTS { agnSActiveCnfg }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon change of the active Configuration DB.
|
|
Attached, is the new active Configuration no."
|
|
::= { muxHubEvents 3 }
|
|
|
|
flipDbChangeTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon change of the active Flip tables
|
|
(Flip DB)."
|
|
::= { muxHubEvents 4 }
|
|
|
|
statusChangedTrap NOTIFICATION-TYPE
|
|
OBJECTS { agnLed }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon any change of the LEDs status."
|
|
::= { muxHubEvents 5 }
|
|
END
|
|
|