RAD-Mpmx-MIB DEFINITIONS ::= BEGIN
-- It is RAD's intent to encourage the widespread use of
-- this Specification in connection with the management of
-- RAD products. RAD grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of RAD products.
-- This Specification is supplied "as is," and RAD makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
IMPORTS
ifAlias, ifIndex FROM IF-MIB
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
Integer32, Counter32, IpAddress,
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY,
NOTIFICATION-TYPE, OBJECT-IDENTITY FROM SNMPv2-SMI
DisplayString, RowStatus, TruthValue FROM SNMPv2-TC
radWan, wanGen FROM RAD-SMI-MIB
agnLed, alarmEventLogSourceName, alarmEventLogAlarmOrEventId,
alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime,
alarmEventReason FROM RAD-GEN-MIB
CardType, ProtectLastSwitchReasonType FROM RAD-TC;
chasWanGen MODULE-IDENTITY
LAST-UPDATED "201609182024Z" -- September 18, 2016
ORGANIZATION "RAD Data Communications Ltd."
CONTACT-INFO
"System Department
Email: mibs@rad.com
Postal: RAD Data Communications Ltd.
24 Raoul Wallenberg St.
Tel-Aviv 6971920
Israel
Phone: +972-3-645-5421
Fax: +972-3-760-7844"
DESCRIPTION
"Megaplex Maccess MIB."
::= { wanGen 1 }
muxHub OBJECT IDENTIFIER ::= {radWan 2}
-- ----------------------------------------------------------------------------------------------
-- chasWanGen OBJECT IDENTIFIER ::= {wanGen 1}
agnWanGen OBJECT IDENTIFIER ::= {wanGen 2}
mdlWanGen OBJECT IDENTIFIER ::= {wanGen 3}
prtWanGen OBJECT IDENTIFIER ::= {wanGen 4}
mapWanGen OBJECT IDENTIFIER ::= {wanGen 5}
diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6}
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} defined RAD-Diverse-IF-MIB
--ethIf OBJECT IDENTIFIER ::= {diverseIfWanGen 1} (see ethif.txt)
--sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} (see radsonet.txt)
--ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} (see radds3.txt)
--ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} (see radds1.txt)
--hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} (see radhdlc.txt)
--v51If OBJECT IDENTIFIER ::= {diverseIfWanGen 6} (see v51.txt)
--ip2If OBJECT IDENTIFIER ::= {diverseIfWanGen 7} (see ipmux.txt)
--broadbandIf OBJECT IDENTIFIER ::= {diverseIfWanGen 8} (see bdband.txt)
--r2If OBJECT IDENTIFIER ::= {diverseIfWanGen 9} (see r2.txt)
--adslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 10} (see radadsl.txt)
--sdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 11} (see radsdsl.txt)
--shdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 12} (see radshdsl.txt)
--voiceIf OBJECT IDENTIFIER ::= {diverseIfWanGen 13} (see voiceIf.txt)
--gsmInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 14} (see radGsm.txt)
--ds0BundleIf OBJECT IDENTIFIER ::= {diverseIfWanGen 15} (see radds0.txt)
--pdhInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 16} (see radpdh.txt)
--voipWanGen OBJECT IDENTIFIER ::= {wanGen 7} (see voip.txt)
statAgnGen OBJECT IDENTIFIER ::= {agnWanGen 1}
cnfgAgnGen OBJECT IDENTIFIER ::= {agnWanGen 2}
cmprAgnGen OBJECT IDENTIFIER ::= {agnWanGen 3}
alrBuffGen OBJECT IDENTIFIER ::= {agnWanGen 4}
agnFlipDb OBJECT IDENTIFIER ::= {agnWanGen 5}
agnSa OBJECT IDENTIFIER ::= {agnWanGen 6}
agnListDecoding OBJECT IDENTIFIER ::= {agnWanGen 7}
agnSystemDlci OBJECT IDENTIFIER ::= {agnWanGen 8}
agnVoiceSwitching OBJECT IDENTIFIER ::= {agnWanGen 9}
agnSigProfile OBJECT IDENTIFIER ::= {agnWanGen 10}
agnSystemTs OBJECT IDENTIFIER ::= {agnWanGen 11}
systemVoice OBJECT IDENTIFIER ::= {agnWanGen 12}
statMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 1}
cnfgMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 2}
cmprMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 3}
statPrtGen OBJECT IDENTIFIER ::= {prtWanGen 1}
cnfgPrtGen OBJECT IDENTIFIER ::= {prtWanGen 2}
cmprPrtGen OBJECT IDENTIFIER ::= {prtWanGen 3}
--statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3} - Statistics of Ports
--prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1}
--prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2}
--prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3}
--prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4}
agnMux OBJECT IDENTIFIER ::= {muxHub 1}
mdlMux OBJECT IDENTIFIER ::= {muxHub 2}
prtMux OBJECT IDENTIFIER ::= {muxHub 3}
--cnfgMdlMux OBJECT IDENTIFIER ::= {mdlMux 1}
--statMdlMux OBJECT IDENTIFIER ::= {mdlMux 2}
statPrtMux OBJECT IDENTIFIER ::= {prtMux 1}
cnfgPrtMux OBJECT IDENTIFIER ::= {prtMux 2}
statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3}
prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1}
prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2}
prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3}
prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4}
--
--prtSExHsfStatTable OBJECT IDENTIFIER ::= {statPrtMux 6}
--prtIsdnStatusTable OBJECT IDENTIFIER ::= {statPrtMux 16}
--
prtClCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 1}
prtPh1MlCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 2} --MPH1/e1/t1
prtPhPlCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 3} --MPH1,MPH3,MPL6
prtLs2Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 4} --LS2 family
--prtVc2CnfgTable OBJECT IDENTIFIER ::= {cnfgPrtMux 5}
--prtHsfCnfgTable OBJECT IDENTIFIER ::= {cnfgPrtMux 6}
prtHs4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 7}
prtHsiCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 8}
prtPVc4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 9}
prtHsrCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 10}
prtMbeCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 11}
prtTreCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 12}
prtLs6Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 13}
prtVc3Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 14}
prtVcPbxCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 15}
prtIsdnCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 16}
prtLogicalCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 17}
prtFrPlusCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 18}
prtMl4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 19}
prtAcmCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 20}
prtE2Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 21}
prtLanWanCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 22}
--
-- Wan chassis general information
--
chasVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An ASCII string for description and display of the agent chassis version."
::= { chasWanGen 1 }
chasTotalNoOfSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the number of physical slots in the
chassis."
::= { chasWanGen 2 }
chasTotalNoOfIoSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the total number of physical IO slots
in the chassis, (not all slots hardware should be occupied
and active) ."
::= { chasWanGen 3 }
chasTotalNoOfPsSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the number of physical Power Supply
slots in the chassis."
::= { chasWanGen 4 }
chasTotalNoOfClSlt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the number of physical Common Logic slots in the
chassis."
::= { chasWanGen 5 }
--
-- Wan agent status general information
--
agnSDateFormat OBJECT-TYPE
SYNTAX INTEGER
{
ddMMYYYY (1),
mmDDYYYY (2),
yyyyDDMM (3),
yyyyMMDD (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the date and time format used for the
agnSDateAndTimeCmd and for the alarm history report."
::= { statAgnGen 1 }
agnSDateCmd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the current date as it is known by the
agent using its own real-time clock. The format would be as
specified by the agnSDateFormat.
This parameter can be set for time synchronization between
the NMS and the Agent."
::= { statAgnGen 2 }
agnSTimeCmd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the current time as it is known by the
agent using its own real-time clock.
This parameter can be set for time synchronization between
the NMS and the Agent."
::= { statAgnGen 3 }
agnSActiveCnfg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the unique identifier of the configuration,
that is currently active and running."
::= { statAgnGen 4 }
-- return 1 (db1) in phase I
agnSEditCnfg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the unique identifier of the
configuration that is currently loaded into the tmp working
space for manipulation and update operations. Value of 255
means no config. is under editing process."
::= { statAgnGen 5 }
-- return 1 (db1) in phase I
agnSLastCnfgFlipTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the Date & Time of the last flip to the
current configuration at the agent."
::= { statAgnGen 6 }
-- return sysUpTime in phase I
agnSLastCnfgFlipCause OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry describes the flip's cause."
::= { statAgnGen 7 }
-- In phase I return two causes:
-- Power up
-- Update Db
agnSEditBy OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
snmp (2),
terCon1 (3),
terCon2 (4),
terInbandCon1 (5),
terInbandCon2 (6),
lcd (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates which MMI application is working on the
edited config.
The editing phase starts at the first modify operation and
ends after an update(load) operation."
::= { statAgnGen 8 }
agnSClkSrc OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
fallback(2),
internal(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the source of the system clock."
::= { statAgnGen 9 }
agnSAlrStatus OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the agent level, i.e. lower
level (card/port) alarms not included.
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { statAgnGen 10 }
agnSAlrStatusAll OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state of the entire agent, i.e.
including card and port alarms status.
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { statAgnGen 11 }
agnSMaskedAlrStat OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the agent level,[ i.e. lower
level (card/port) alarms not included] including Masked
alarms.
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { statAgnGen 12 }
agnSMaskedAlrStatAll OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state of the entire agent, i.e.
including card and port alarms status,including
Masked alarms.
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { statAgnGen 13 }
agnSTstStatAll OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"on(3) - when there is at least one test in progress in one
of the agent cards,
otherwise the value will be off(2)."
::= { statAgnGen 14 }
agnSAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of agent related alarms and indications for alarms at
system level."
::= { statAgnGen 15 }
agnSAlrEntry OBJECT-TYPE
SYNTAX AgnSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnSAlrIdx}
::= { agnSAlrTable 1}
AgnSAlrEntry ::=
SEQUENCE {
agnSAlrIdx Integer32,
agnSAlrCodeDescription DisplayString,
agnSAlrCode Integer32,
agnSAlrSeverity INTEGER,
agnSAlrState INTEGER,
agnSAlrCounter Integer32,
agnSAlrMask INTEGER,
agnSAlrInvert INTEGER
}
agnSAlrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table
of the agent."
::= { agnSAlrEntry 1 }
agnSAlrCodeDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a full text description of the alarm .
The alarm description includes the following information:
alarm code, alarm text, alarm severity, Masked or Inverted
flag and counter."
::= { agnSAlrEntry 2 }
agnSAlrCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A code identifying the alarm of an entry in the alarm status
table at system level."
::= { agnSAlrEntry 3 }
agnSAlrSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm."
::= { agnSAlrEntry 4 }
agnSAlrState OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the alarm."
::= { agnSAlrEntry 5 }
agnSAlrCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A counter - how many times the alarm occured since last
clear operation.
ON and OFF Alarm will be counted separately."
::= { agnSAlrEntry 6 }
agnSAlrMask OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm mask : on/off."
::= { agnSAlrEntry 7 }
agnSAlrInvert OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm invert : on/off."
::= { agnSAlrEntry 8 }
agnSClearAlrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, enforce a clear operation on
all the agent(general) events. General alarms are alarms
which are not specific to a card or port. The clear
operation will not be applied for masked/inverted alarms."
::= { statAgnGen 16 }
agnSClearAllAlrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, enforce a clear operation on
all MUX alarm events at the levels of agent, slots and ports.
The clear operation will not be applied for masked/inverted
alarms."
::= { statAgnGen 17 }
agnSSanityCheckStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
fail (2),
warning (3),
ok (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upon completion of the Sanity check process on the TmpCnfg
this attribute will be set to:
FAIL(2) - when there is at least one error encountered and
possibly some warnings.
WARNING(3) - when there are only warnings.
otherwise, the value will be OK(4).
The value will be UNKNOWN(1) if changes were made in the
TmpCnfg following the last Sanity check."
::= { statAgnGen 18 }
agnSNoOfSanityCheckErr OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the number of errors/warnings discovered
by the last SanityCheck process."
::= { statAgnGen 19 }
agnSErrListTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSErrListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of errors and warnings found during Sanity Check
process."
::= { statAgnGen 20 }
agnSErrListEntry OBJECT-TYPE
SYNTAX AgnSErrListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnSErrIdx}
::= { agnSErrListTable 1}
AgnSErrListEntry ::=
SEQUENCE {
agnSErrIdx Integer32,
agnSErrDescription DisplayString
}
agnSErrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify an entry in the error list table.
The maximum entry value cannot exceed the value of
'agnSNoOfSanityCheckErr'. "
::= { agnSErrListEntry 1}
agnSErrDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a full text description of the sanity check
error including error code, slot and port numbers related to
the code ."
::= { agnSErrListEntry 2}
agnSMaxNoOfCnfg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum number of configurations that can be defined and
stored in the MUX.
If the mux has a large capacity, the maximum will be limited
to 254."
::= { statAgnGen 21}
-- return 1 (db1) in phase I
agnSCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains an entry per configuration. It indicates
if the configuration is valid."
::= { statAgnGen 22 }
-- - in phase I only one entry
agnSCnfgEntry OBJECT-TYPE
SYNTAX AgnSCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnSEntryIdx}
::= {agnSCnfgTable 1}
AgnSCnfgEntry ::=
SEQUENCE {
agnSEntryIdx Integer32,
agnSEntryIsValid INTEGER
}
agnSEntryIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify an entry in the configuration table."
::= { agnSCnfgEntry 1}
agnSEntryIsValid OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates whether the specific configuration
is valid in the MUX . Value of NO indicates: no such
configuration in the MUX. "
::= { agnSCnfgEntry 2}
--
-- Wan agent configuration information
--
agnCSanityCheckCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on(3) will initiate the process
of Sanity check on the TmpCnfg. Upon completion the value
will automatically be changed to off(2)."
::= { cnfgAgnGen 1 }
agnCSaveCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute specifies the Id of the target RealCnfg to
which the TmpCnfg should be transferred. Upon set command the
MUX will initiate the Sanity-Check process first. If
successful, the actual transfer will be performed. If warnings
are detected, the user will have to perform the command again
to confirm the operation. Setting this object a second time
to the same value without performing any change in the database,
will cause the result: agnSSanityCheckStatus = unknown"
::= { cnfgAgnGen 2 }
-- In phase I only the value 1 (Cnfg1) is valid.
agnCLoadCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute specifies the Id of the source Cnfg to be
loaded into the TmpCnfg. Upon set operation the actual
transfer will be initiated.
The operation is valid only on Valid configurations
(agnSEntryIsValid)"
::= { cnfgAgnGen 3 }
-- In phase I only the value 1 (Cnfg1) is valid.
agnCClkSrcTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All the entries of this table are identical (have the same
value) for all the configurations (1..100) except the
TmpCnfg.
The write operation into the Table Objects is valid only
for the TmpCnfg entry."
::= { cnfgAgnGen 4}
agnCClkSrcEntry OBJECT-TYPE
SYNTAX AgnCClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCClkCnfgIdx, agnCClkSrcIdx}
::= { agnCClkSrcTable 1}
AgnCClkSrcEntry ::=
SEQUENCE {
agnCClkCnfgIdx Integer32,
agnCClkSrcIdx Integer32,
agnCClkSrcMode INTEGER,
agnCClkSrcSlt INTEGER,
agnCClkSrcPrt Integer32
}
agnCClkCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..100) being
accessed and Idx 255 relates to the TmpCnfg."
::= { agnCClkSrcEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
agnCClkSrcIdx OBJECT-TYPE
SYNTAX Integer32 (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index to the table. There are only two entries to this
table.
Index 1 points to the Master clock parameters and Index 2
points to the Fallback clock parameters"
::= { agnCClkSrcEntry 2}
agnCClkSrcMode OBJECT-TYPE
SYNTAX INTEGER
{
internal (1),
rxClk (2),
adaptive (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source of the nodal timing."
::= { agnCClkSrcEntry 3}
agnCClkSrcSlt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is valid only when we are working in rxClk mode.
For an invalid entry, the return value will be '7fff'h."
::= { agnCClkSrcEntry 4}
agnCClkSrcPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is valid only when we are working in rxClk or
adaptive mode.
For an invalid entry, the return value will be '7fff'h.
- For rxClk mode, the values can be:
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
notApplicable (100),
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104)
- For adaptive mode, the value will be the ifIndex of the
selected IP Bundle."
::= { agnCClkSrcEntry 5}
agnCDeleteCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute will delete the requested DB
from the NVRAM ."
::= { cnfgAgnGen 5 }
agnCDefaultCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute will define the desired working
configuration when no conditions of the Flip DB Table are
fulfilled and no Net GO command was issued. This command
will be accepted only if the Configuration number exists
(agnSEntryIsValid=yes)."
::= { cnfgAgnGen 6 }
agnCnfgDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCnfgDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains data about the agent configurations.
The table will support only data about valid configurations
of the agent."
::= { cnfgAgnGen 7}
agnCnfgDataEntry OBJECT-TYPE
SYNTAX AgnCnfgDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCnfgIdx}
::= { agnCnfgDataTable 1}
AgnCnfgDataEntry ::=
SEQUENCE {
agnCnfgIdx Integer32,
agnCnfgDesc DisplayString,
agnCnfgUpdDate DisplayString,
agnCnfgUpdTime DisplayString,
agnCnfgUpdMnger IpAddress
}
agnCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the agent' Cnfg the following
objects refer.
255=Temporary Cnfg (Set is done only to this configuration)."
::= { agnCnfgDataEntry 1}
-- Only the values 1..10, 255 are valid.
agnCnfgDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a description of the Configuration, entered
by user, to enhance Cnfg recognition."
::= { agnCnfgDataEntry 2}
agnCnfgUpdDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the date when last update of this
configuration was performed, as it is known by the
agent using its own real-time clock. The format would be as
specified by the agnSDateFormat.
When update is performed, the agent should save the date."
::= { agnCnfgDataEntry 3 }
agnCnfgUpdTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the time when last update of this
configuration was performed, as it is known by the
agent using its own real-time clock.
When update is performed, the agent should save the time."
::= { agnCnfgDataEntry 4 }
agnCnfgUpdMnger OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the IP Address of the Manager who
performed the last update of this configuration.
When update is performed, the agent should save the
IP Address of the Manager who commanded the update.
That will enable a manager to know if he performed the last
update, or another manager did."
::= { agnCnfgDataEntry 5 }
agnCnfgAlarm OBJECT IDENTIFIER ::= { cnfgAgnGen 8}
agnCnfgAlrFilterWindow OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Window of time, in seconds.
During this Window, the alarms filter is performed.
Same Window for all agent alarms that need filtering.
Upon end of the Window, the state of the alarm is updated
and a new Window starts.
If no alarm needs filtering, this object's value will not be
used."
::= { agnCnfgAlarm 1}
agnCnfgAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCnfgAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table enables the user to set attributes to each alarm.
Setting for a non-existing entry agnCnfgAlrMask,
agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave
for Mask) will add this new entry to the table.
Setting for an existing entry agnCnfgAlrMask/
agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no'
(noAndSave for Mask) so that ALL these objects' values are
'no' , will delete this entry from the table.
For agnCnfgAlrMask, only if [(last saved value=noAndSave)
AND (new value is 'no' or 'noAndSave')] the object's value
is considered 'no' for deleting the entry.
For some products (like MP, MPH, Vmux2100) the Active Alarms are always
part of the table and cannot be removed even if their Mask/Invert/Filter
are No."
::= { agnCnfgAlarm 2}
agnCnfgAlrEntry OBJECT-TYPE
SYNTAX AgnCnfgAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCnfgAlrCode, agnCnfgAlrSlot, agnCnfgAlrPort}
::= { agnCnfgAlrTable 1}
AgnCnfgAlrEntry ::=
SEQUENCE {
agnCnfgAlrCode Integer32,
agnCnfgAlrSlot INTEGER,
agnCnfgAlrPort Integer32,
agnCnfgAlrMask INTEGER,
agnCnfgAlrInvert INTEGER,
agnCnfgAlrFilter INTEGER,
agnCnfgAlrFilterSet Integer32,
agnCnfgAlrFilterReset Integer32,
agnCnfgAlrSeverity INTEGER
}
agnCnfgAlrCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm code. The following attributes refer this code."
::= { agnCnfgAlrEntry 1 }
agnCnfgAlrSlot OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
all (200),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm slot. The following attributes apply for the alarm
code and slot selected.
all = the attributes apply to all slots.
notApplicable = the selected alarm is for system level.
For the Vmux2100 Main Board clA (3) is used."
::= { agnCnfgAlrEntry 2 }
agnCnfgAlrPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm port. The following attributes apply for the alarm
code,slot and port selected.
200 = all = the attributes apply to all ports of the selected slot.
When selected Slot is 'all', only 'all' or 'notApplicable' are valid
Port selections.
notApplicable = the selected alarm is for system or card
level.
=255 for MP
=100 for DXC
- For MP:
- valid cards' ports are: exPrt1(1)..exPrt16(16)
inPrt1(101)..inPrt48 (148)
- IP Bundles
- For DXC, the port index will include the Slot, as for all DXC
tables: [(IO Slot+10)&n] ; n=odd for external ports
n=even for internal ports."
::= { agnCnfgAlrEntry 3 }
agnCnfgAlrMask OBJECT-TYPE
SYNTAX INTEGER
{
no (1),
noAndSave (2),
yes (3),
yesAndSave (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An attribute defining the desired Mask state of an alarm .
no - unmask (this command is not saved in agent's common
database)
noAndSave - unmask ; this command is saved in agent's
common database
yes - mask (this command is not saved in agent's
common database)
yesAndSave - mask ; this command is saved in
agent's common database.
Commands that are not saved, will be lost upon power-up or
selected card removal. "
::= { agnCnfgAlrEntry 4 }
agnCnfgAlrInvert OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An attribute defining the desired Invert state of an alarm .
no - not inverted.
yes - inverted. For MP, it is not applicable for alarms
that are currently OFF."
::= { agnCnfgAlrEntry 5 }
agnCnfgAlrFilter OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An attribute defining if Filter is desired for the alarm .
no - no filter.
yes - filter activate.
This filter is activated within a window of time defined by
agnCnfgAlrFilterWindow.
Its purpose is to avoid frequent changes of an alarm between
ON/OFF states."
::= { agnCnfgAlrEntry 6 }
agnCnfgAlrFilterSet OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a top threshold causing the alarm that passes it,
to be declared Set (ON) at the end of the respective
window of time.
- For alarms defined by default as state alarms (minor,major)
this value will be in [%].
- For alarms defined by default as events, this value will be
an integer meaning how many times this event should appear
at least, during the window in order to be considered ON.
The maximum value will be 255.
This value should be greater than the one of
agnCnfgAlrFilterReset.
Agents that do not support Alarms Filter, will return 0."
::= { agnCnfgAlrEntry 7 }
agnCnfgAlrFilterReset OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is a bottom threshold causing the alarm that does not
pass it, to be declared Reset (ON) at the end of the
respective window of time.
- For alarms defined by default as state alarms (minor,major)
this value will be in [%].
- For alarms defined by default as events, this value will be
an integer meaning how many times this event should appear
at most, during the window, in order to be considered OFF.
This value should be less than the one of
agnCnfgAlrFilterSet.
Agents that do not support Alarms Filter, will return 0."
::= { agnCnfgAlrEntry 8 }
agnCnfgAlrSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An attribute defining desired severity of an alarm code
per slot/port "
::= { agnCnfgAlrEntry 9 }
agnCnfgAlrReportTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCnfgAlrReportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table enables the user to configure the desired Alarm
Reports according to alarms severity."
::= { agnCnfgAlarm 3}
agnCnfgAlrReportEntry OBJECT-TYPE
SYNTAX AgnCnfgAlrReportEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCnfgAlrReportType}
::= { agnCnfgAlrReportTable 1}
AgnCnfgAlrReportEntry ::=
SEQUENCE {
agnCnfgAlrReportType INTEGER,
agnCnfgAlrStartReportOn INTEGER,
agnCnfgAlrStartReportOff INTEGER
}
agnCnfgAlrReportType OBJECT-TYPE
SYNTAX INTEGER
{
trap (1),
buffer (2),
relay (3), --Relay 1 = R1
alrLedOn (4), --Minor LED
alrLedBlink (5), --Major LED
relay2 (6) --Relay 2 = R2
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The alarm report type.
trap - traps will be sent only for alarms having the
selected On/Off severity or higher.
buffer - only alarms having the selected On/Off severity and
higher, will be reported to the buffer.
relay - relay contact will be activated only for alarms
having the selected On severity or higher.
For products having 2 relays, this is the R1 Relay.
alrLedOn/alrLedBlink - user should select a higher severity
(ReportOn) for alrLedBlink than for alrLedOn
(Blinking Led means a more severe alarm than steady
ON Led).
alrLedOn - MTCL-1 Alarm Led will be ON only when
agnSAlrStatusAll equals the selected severity or
higher, but lower severity than that selected for
'alrLedBlink'.
For products having 2 LEDs, this is the Minor LED.
alrLedBlink - MTCL-1 Alarm Led will Blink only when
agnSAlrStatusAll equals the selected severity or
higher.
For products having 2 LEDs, this is the Major LED.
relay2 - relay 2 contact will be activated only for alarms
having the selected On severity or higher.
This is the R2 Relay."
::= { agnCnfgAlrReportEntry 1 }
agnCnfgAlrStartReportOn OBJECT-TYPE
SYNTAX INTEGER
{
noReport (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the severity from which alarms will
be reported. Alarms having this severity or higher, will be
reported.
This object specifies the report severity only for alarms
that turn to ON state.
noReport - no Report at all (for any severity)."
::= { agnCnfgAlrReportEntry 2 }
agnCnfgAlrStartReportOff OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
noReport (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the severity from which alarms will
be reported. Alarms having this severity or higher, will be
reported.
This object specifies the report severity only for alarms
that turn to OFF state.
notApplicable - for 'relay','alrLedOn','alrLedBlink', 'relay2' report
types, in MP.
noReport - no Report at all (for any severity)."
::= { agnCnfgAlrReportEntry 3 }
agnCOffsetCmd OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
u1 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An object defining special user request.
notApplicable - is RO value for products that do not support this object.
normal - nothing special
u1 - user 1 - for all Voice cards, the DISPLAYED Tx and Rx Levels
will have the following Offsets:
- 2 Wires port: Tx Level: the base value (for 0dBm) = 0
Rx Level: the base value (for 0dBm) = -2
- 4 Wires port: Tx Level: the base value (for 0dBm) = -16
Rx Level: the base value (for 0dBm) = 7
The MIB and application DB will use the values without Offset."
::= { cnfgAgnGen 9 }
--System T1/E1 Ring Table
--
--This table contains all ML ports that participate in a T1/E1 Ring,
--and their ML port pair.
--The table indexes are Cnfg and the Primary card & port
agnCT1E1RingTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCT1E1RingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration of all T1/E1 Ring ML cards and ports.
The write operation into the table objects is valid only
for the TmpCnfg.
A Slot/Port that does not participate in the T1/E1 Ring,
will not exist in this table.
A ML port that exists in this table, cannot exist at the same
time in the IO Redundancy table (sysCRdnTable)."
::= { cnfgAgnGen 10 }
agnCT1E1RingEntry OBJECT-TYPE
SYNTAX AgnCT1E1RingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Entry in table agnCT1E1RingTable"
INDEX { agnCT1E1RingCnfgIdx, agnCT1E1RingPrimeSlot, agnCT1E1RingPrimePort}
::= { agnCT1E1RingTable 1}
AgnCT1E1RingEntry ::=
SEQUENCE {
agnCT1E1RingCnfgIdx Integer32,
agnCT1E1RingPrimeSlot INTEGER,
agnCT1E1RingPrimePort Integer32,
agnCT1E1RingSecSlot INTEGER,
agnCT1E1RingSecPort Integer32,
agnCT1E1RingRecTime Integer32,
agnCT1E1RingRowStatus RowStatus,
agnCT1E1RingWTR Unsigned32,
agnCT1E1RingDualFailDetection INTEGER
}
agnCT1E1RingCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= { agnCT1E1RingEntry 1 }
agnCT1E1RingPrimeSlot OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot number of the Primary card of the Ring Pair."
::= { agnCT1E1RingEntry 2 }
agnCT1E1RingPrimePort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number in the Primary Card.
For external ports, the value will be as that of the port in the
card. Example: external-3 -> 3
external-4 -> 4
For internal ports, the value will be 100 + the port in the
card. Example: internal-1 -> 101
internal-4 -> 104 "
::= { agnCT1E1RingEntry 3 }
agnCT1E1RingSecSlot OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The slot number of the Secondary card of the Ring Pair."
::= { agnCT1E1RingEntry 4 }
agnCT1E1RingSecPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The port number in the Secondary Card.
For external ports, the value will be as that of the port in the
card. Example: external-3 -> 3
external-4 -> 4
For internal ports, the value will be 100 + the port in the
card. Example: internal-1 -> 101
internal-4 -> 104 "
::= { agnCT1E1RingEntry 5 }
agnCT1E1RingRecTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"T1/E1 Ring Recovery Time (sec).
Valid Values: 1..99, 65535.
65535=NA."
::= { agnCT1E1RingEntry 6 }
agnCT1E1RingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter allows NMS to create/delete entries of this table.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { agnCT1E1RingEntry 7 }
agnCT1E1RingWTR OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"T1/E1 Ring Wait to Restore (sec).
Valid Values: 0..999, 65535.
65535=NA.
When the value <> 65535, the value of agnCT1E1RingRecTime must be 65535."
::= { agnCT1E1RingEntry 8 }
agnCT1E1RingDualFailDetection OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"T1/E1 Ring - Dual Failure Detection enable/disable."
::= { agnCT1E1RingEntry 9 }
agnCMainExitPort OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
eth (2),
e1T1SerialLink (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An object defining the Main Exit Port for the Data of the device.
In the Vmux-120 Device the Data can Exit via one of the 2 existing ports:
1. Ethernet port (2)
2. A port that can be E1 or T1 or a Serial Link (3)."
::= { cnfgAgnGen 11 }
-- Backup Configuration Table for Main Link Module
agnCBuMlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCBuMlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration for Primary, Secondary and Third Link.
These are used for Link Backup."
::= { cnfgAgnGen 12 }
agnCBuMlEntry OBJECT-TYPE
SYNTAX AgnCBuMlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Entry in table agnCBuMlTable"
INDEX { agnCBuMlCnfgIdx, agnCBuMlRole}
::= { agnCBuMlTable 1}
AgnCBuMlEntry ::=
SEQUENCE {
agnCBuMlCnfgIdx Integer32,
agnCBuMlRole INTEGER,
agnCBuMlType INTEGER,
agnCBuMlDefaultGateway IpAddress,
agnCBuMlSubnetMask IpAddress,
agnCBuMlOamFrequency Integer32,
agnCBuMlOamTimeoutCycles Integer32,
agnCBuMlWaitToRestore Unsigned32,
agnCBuMlBfdSessionNum Unsigned32
}
agnCBuMlCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the Configuration database (1..255) being
accessed. Index of 255 relates to the Temporary Configuration."
::= { agnCBuMlEntry 1 }
agnCBuMlRole OBJECT-TYPE
SYNTAX INTEGER
{
primary (2),
secondary (3),
third (4),
fourth (5)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Role of the Link. Primary Link is the Link that should usually work.
If the Primary Link fails, the data will go through the Secondary Link.
If both Primary and Secondary Links fail, the data will go through the Third
Link, provided it is up."
::= { agnCBuMlEntry 2 }
agnCBuMlType OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
e1T1a (3),
e1T1b (4),
eth (5),
ethNetUser (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Type of the Link.
For E1/T1 the Link can be Link A - e1T1a or Link B - e1T1b.
For ETH-NET, eth (5) can be used.
For ETH-NET/USER ethNetUser (6) can be used."
::= { agnCBuMlEntry 3 }
agnCBuMlDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Gateway's IP Address."
::= { agnCBuMlEntry 4 }
agnCBuMlSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Link subnet mask."
::= { agnCBuMlEntry 5 }
agnCBuMlOamFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time in sec. between 2 OAM packets."
::= { agnCBuMlEntry 6 }
agnCBuMlOamTimeoutCycles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"No. of cycles the Link will send OAM packets without receiving a response
from the remote Link before switching to the Backup Link."
::= { agnCBuMlEntry 7 }
agnCBuMlWaitToRestore OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines traffic recovery time (in milliseconds)
of the link after its recovery.
This object is applicable only when Recovery Mode is revertive."
::= { agnCBuMlEntry 8 }
agnCBuMlBfdSessionNum OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the BFD (Bidirectional Forwarding Detection) session number of the link.
When no session exists or when N/A, the value will be 0."
::= { agnCBuMlEntry 9 }
agnCQ50Table OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCQ50Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table for the device Q50 parameters.
Q50 is a Signaling protocol used between PBX devices.
It is possible to control the initiation of calls using Q.50.
This is useful for devices when there is a congestion."
::= { cnfgAgnGen 13 }
agnCQ50Entry OBJECT-TYPE
SYNTAX AgnCQ50Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Entry in table agnCQ50Table"
INDEX { agnCQ50CnfgIdx}
::= { agnCQ50Table 1}
AgnCQ50Entry ::=
SEQUENCE {
agnCQ50CnfgIdx Integer32,
agnCQ50StopCallsThresh Integer32,
agnCQ50DiscardPktThresh Integer32,
agnCQ50BlockNewModemVbdCallsThresh Integer32,
agnCQ50BlockNewModemRelayCallsThresh Integer32
}
agnCQ50CnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the Configuration database (1..255) being
accessed. Index of 255 relates to the Temporary Configuration."
::= { agnCQ50Entry 1 }
agnCQ50StopCallsThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Bandwidth Threshold percent (%) above which
new Calls from the PBX will be disabled."
::= { agnCQ50Entry 2 }
agnCQ50DiscardPktThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Bandwidth Threshold percent (%) above which
voice packets will be discarded. Usually, the value selected should be higher
than the value of agnCQ50StopCallsThresh."
::= { agnCQ50Entry 3 }
agnCQ50BlockNewModemVbdCallsThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Modem VBD Calls Threshold percent (%) above which
new modem calls will be rejected."
::= { agnCQ50Entry 4 }
agnCQ50BlockNewModemRelayCallsThresh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Modem Relay Calls Threshold percent (%) above which
new modem calls will be rejected."
::= { agnCQ50Entry 5 }
--
-- Compressed information.
--
-- Specially for RadView management station
--
agnCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprAgnGen 1 }
agnCmprEntry OBJECT-TYPE
SYNTAX AgnCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnCmprTypIdx, agnCmprCnfgIdx ,agnCmprVersion}
::= {agnCmprTable 1}
AgnCmprEntry ::=
SEQUENCE {
agnCmprTypIdx Integer32,
agnCmprCnfgIdx Integer32,
agnCmprVersion Integer32,
agnCmprObj OCTET STRING
}
agnCmprTypIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Type of the Compressed being
referred."
::= { agnCmprEntry 1}
agnCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the configuration to which the
Compressed information is related."
::= { agnCmprEntry 2}
agnCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format
of the Compressed data"
::= { agnCmprEntry 3}
agnCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { agnCmprEntry 4}
-- Compressed Dlci table in the Agent level
-- The only way of reading this table is by the command 'GET NEXT'
agnDlciCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnDlciCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {cmprAgnGen 2}
agnDlciCmprEntry OBJECT-TYPE
SYNTAX AgnDlciCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnDlciCmprCnfgIdx,agnDlciCmprVersion,agnDlciCmprDlciIdx}
::= {agnDlciCmprTable 1}
AgnDlciCmprEntry ::=
SEQUENCE {
agnDlciCmprCnfgIdx Integer32,
agnDlciCmprVersion Integer32,
agnDlciCmprDlciIdx Integer32,
agnDlciCmprObj OCTET STRING
}
agnDlciCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the configuration to which the
Compressed information is related."
::= { agnDlciCmprEntry 1}
agnDlciCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format
of the Compressed data"
::= { agnDlciCmprEntry 2}
agnDlciCmprDlciIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the Dlci,
the compressed information relates to.
The values are between 16 - 991."
::= { agnDlciCmprEntry 3}
agnDlciCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { agnDlciCmprEntry 4}
-- Compressed Status Alarm table at the Agent level
-- The only way of reading this table is by the command 'GET NEXT'
agnAlarmsCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {cmprAgnGen 3}
agnAlarmsCmprEntry OBJECT-TYPE
SYNTAX AgnAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnAlarmsCmprVersion,agnAlarmsCmprAlarmIdx}
::= {agnAlarmsCmprTable 1}
AgnAlarmsCmprEntry ::=
SEQUENCE {
agnAlarmsCmprVersion Integer32,
agnAlarmsCmprAlarmIdx Integer32,
agnAlarmsCmprObj OCTET STRING
}
agnAlarmsCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal
format of the Compressed data"
::= { agnAlarmsCmprEntry 1}
agnAlarmsCmprAlarmIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table
of the agent."
::= { agnAlarmsCmprEntry 2}
agnAlarmsCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { agnAlarmsCmprEntry 3}
-- Compressed History Alarms buffer
-- The only way of reading this table is by the command 'GET NEXT'
agnAlrBufCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnAlrBufCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {cmprAgnGen 4}
agnAlrBufCmprEntry OBJECT-TYPE
SYNTAX AgnAlrBufCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnAlrBufCmprVersion,agnAlrBufCmprAlarmIdx}
::= {agnAlrBufCmprTable 1}
AgnAlrBufCmprEntry ::=
SEQUENCE {
agnAlrBufCmprVersion Integer32,
agnAlrBufCmprAlarmIdx Integer32,
agnAlrBufCmprObj OCTET STRING
}
agnAlrBufCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format of
the Compressed data"
::= { agnAlrBufCmprEntry 1}
agnAlrBufCmprAlarmIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the history alarms
buffer of the agent."
::= { agnAlrBufCmprEntry 2}
agnAlrBufCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { agnAlrBufCmprEntry 3}
-- Compressed Sanity Errors buffer
-- The only way of reading this table is by the command 'GET NEXT'
agnSCmprErrListTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSCmprErrListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprAgnGen 5 }
agnSCmprErrListEntry OBJECT-TYPE
SYNTAX AgnSCmprErrListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnSCmprErrVersion,agnSCmprErrIdx}
::= { agnSCmprErrListTable 1}
AgnSCmprErrListEntry ::=
SEQUENCE {
agnSCmprErrVersion Integer32,
agnSCmprErrIdx Integer32,
agnSCmprErrObj OCTET STRING
}
agnSCmprErrVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The version of the compressed data "
::= { agnSCmprErrListEntry 1}
agnSCmprErrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique number to identify an entry in the errors list table.
The maximum entry value cannot exceed the value of
'agnSNoOfSanityCheckErr'. "
::= { agnSCmprErrListEntry 2}
agnSCmprErrObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a full text description of the error,
including: error code, slot and port numbers related to the
code ."
::= { agnSCmprErrListEntry 3}
-- New TS Assignment compressed table, per port 01/09/98
-- The only way of reading this table is by the command 'GET NEXT'
agnTsCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnTsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprAgnGen 6 }
agnTsCmprEntry OBJECT-TYPE
SYNTAX AgnTsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnTsCmprVerIdx, agnTsCmprCnfgIdx , agnTsCmprSlotIdx,
agnTsCmprPortIdx, agnTsCmprPduIdx }
::= {agnTsCmprTable 1}
AgnTsCmprEntry ::=
SEQUENCE {
agnTsCmprVerIdx Integer32,
agnTsCmprCnfgIdx Integer32,
agnTsCmprSlotIdx Integer32,
agnTsCmprPortIdx Integer32,
agnTsCmprPduIdx Integer32,
agnTsCmprData OCTET STRING
}
agnTsCmprVerIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the version of the internal format
of the Compressed data."
::= { agnTsCmprEntry 1}
agnTsCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the configuration to which the
Compressed information is related.
255=temporary configuration.
Set can be performed only to the temporary configuration."
::= { agnTsCmprEntry 2}
agnTsCmprSlotIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Slot to which the
Compressed information is related.
For MP-2100: IO-1..IO-12 = (5).. (16)
For DXC-30 : IO-1..IO-15 = (5).. (19).
NA=255."
::= { agnTsCmprEntry 3}
agnTsCmprPortIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Port within the Slot, to which the
Compressed information is related.
For Port Index see each product's spec."
::= { agnTsCmprEntry 4}
agnTsCmprPduIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the PDU index within the same port.
That provides for the case when one PDU is not sufficient for all TS
Assignment data of the same port."
::= { agnTsCmprEntry 5}
agnTsCmprData OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the compressed information itself. It provides
information about all TSs of a port."
::= { agnTsCmprEntry 6}
-- Extended Compress General Table with 7 indexes - 10/02/99
-- Used for: V5.1 and V5.2 Variant
agnXCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnXCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprAgnGen 7 }
agnXCmprEntry OBJECT-TYPE
SYNTAX AgnXCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnXCmprTypIdx, agnXCmprVersion, agnXCmprIdx3,agnXCmprIdx4,
agnXCmprIdx5, agnXCmprIdx6, agnXCmprIdx7}
::= {agnXCmprTable 1}
AgnXCmprEntry ::=
SEQUENCE {
agnXCmprTypIdx Integer32,
agnXCmprVersion Integer32,
agnXCmprIdx3 Integer32,
agnXCmprIdx4 Integer32,
agnXCmprIdx5 Integer32,
agnXCmprIdx6 Integer32,
agnXCmprIdx7 Integer32,
agnXCmprObj OCTET STRING
}
agnXCmprTypIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Type of the Compressed being
referred.
One of the types is V5.1 Variant data."
::= { agnXCmprEntry 1}
agnXCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format of
the Compressed data."
::= { agnXCmprEntry 2}
agnXCmprIdx3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"3rd index - can be used for any purpose according to the
agnXCmprTypIdx.
Example: for V5.1 Variant, this attribute indicates the configuration
to which the Compressed information is related.
255=temporary configuration.
Set can be performed only to the temporary configuration."
::= { agnXCmprEntry 3}
agnXCmprIdx4 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"4th index - can be used for any purpose according to the
agnXCmprTypIdx.
Example: for V5.1 Variant,this attribute indicates a unique number of
the slot position where the card is inserted.
Valid values: psA(1),psB(2),clA(3),clB(4),io1(5)..io12(16); notApplicable=255."
::= { agnXCmprEntry 4}
agnXCmprIdx5 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"5th index - can be used for any purpose according to the
agnXCmprTypIdx.
Example: for V5.1 Variant,this attribute indicates a unique identifier
of the port the compressed information relates to.
Valid values: exPrt1 (1) .. exPrt12 (12) ,
inPrt1 (101) .. inPrt48 (148)."
::= { agnXCmprEntry 5}
agnXCmprIdx6 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"6th index - can be used for any purpose according to the
agnXCmprTypIdx.
Example: for V5.1 Variant,this attribute indicates the Variant index.
Valid values are: 0..127, 255 (= temp cnfg).Set can be performed only
to the temporary configuration."
::= { agnXCmprEntry 6}
agnXCmprIdx7 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"7th index - can be used for any purpose according to the
agnXCmprTypIdx.
Example: for V5.1 Variant,this attribute is not needed. Therefore, its
value will be always 255=notApplicable."
::= { agnXCmprEntry 7}
agnXCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { agnXCmprEntry 8}
--
-- Link Mapping Table for internal use
--
agnLinkMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnLinkMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { mapWanGen 1}
agnLinkMapEntry OBJECT-TYPE
SYNTAX AgnLinkMapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {mapLinkId}
::= {agnLinkMapTable 1}
AgnLinkMapEntry ::=
SEQUENCE {
mapLinkId Integer32,
mapLinkSltIdx INTEGER,
mapLinkPrtIdx INTEGER,
mapLinkStatus INTEGER
}
mapLinkId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the link"
::= {agnLinkMapEntry 1}
mapLinkSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
clA (3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries clA(3), io6(10)..io12(16) are
not valid."
::= {agnLinkMapEntry 2}
mapLinkPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
noConnect (100) ,
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110) ,
inPrt11 (111) ,
inPrt12 (112)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port number. "
::= {agnLinkMapEntry 3}
mapLinkStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
down(2),
up(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the link between the
two muxes"
::= {agnLinkMapEntry 4}
--
-- diverseIfWanGen - diverse NON-DS1 interfaces of WAN products
--
--sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} (see radsonet.txt)
--ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} (see radds3.txt)
--ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} (see radds1.txt)
--hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} (see radhdlc.txt)
--ip2If OBJECT IDENTIFIER ::= { diverseIfWanGen 7 } (see ipmux.txt)
--
-- Wan alarm buffer (history) information
--
alrBufTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlrBufEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { alrBuffGen 1 }
alrBufEntry OBJECT-TYPE
SYNTAX AlrBufEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { alrBufIdx }
::= { alrBufTable 1}
AlrBufEntry ::=
SEQUENCE {
alrBufIdx Integer32,
alrBufDescription DisplayString,
alrBufCode Unsigned32,
alrBufSlot INTEGER,
alrBufPort Unsigned32,
alrBufSeverity INTEGER,
alrBufState INTEGER
}
alrBufIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify this
entry"
::= { alrBufEntry 1}
alrBufDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry is a unique text description of the alarm in the
buffer.
The alarm description includes the following information:
alarm code, slot id, card type, channel id ,
alarm text, alarm status, masked flag and event counter"
::= { alrBufEntry 2}
alrBufCode OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A code identifying the alarm of an entry in the alarm buffer
table."
::= { alrBufEntry 3 }
alrBufSlot OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot number this alarm refers to.
When the alarm refers to a system alarm, the value will be 'notApplicable(255)'."
::= { alrBufEntry 4 }
alrBufPort OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number this alarm refers to.
If the port number is irrelevant to this alarm (if it is
a system/card level alarm) the value will be 9999."
::= { alrBufEntry 5 }
alrBufSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm."
::= { alrBufEntry 6 }
alrBufState OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the alarm (On/Off)."
::= { alrBufEntry 7 }
alrBufferClearCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce a clear
operation on the Alarms Buffer. Upon completion,
the value will automatically change to off(2).
For MP-2100/2200, this command will not really erase
the Alarm Buffer, but is only an ACK of seeing the Buffer.
It marks a pointer of the last entry's alrBufIdx, in order
to allow view of new alarms entered after this pointer
(alrBufIdxUponLastAck)."
::= { alrBuffGen 2 }
alrBufIdxUponLastAck OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the value of alrBufIdx for the
last existing entry of alrBufTable, when alrBufferClearCmd
was last Set to on(3).
That will enable a user to see only Alarms that entered the
alrBufTable after last Set of alrBufferClearCmd, by GetNext
of alrBufDescription with this index."
::= { alrBuffGen 3 }
--
-- Wan Flip Data-Base parameters
--
-- agnCAgendaTable :
--
agnCAgendaTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCAgendaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table devides the week days into categories needed for
DB flip consideration."
::= {agnFlipDb 1}
agnCAgendaEntry OBJECT-TYPE
SYNTAX AgnCAgendaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCAgendaCnfgIdx, agnCAgendaDayIdx}
::= {agnCAgendaTable 1}
AgnCAgendaEntry ::=
SEQUENCE {
agnCAgendaCnfgIdx INTEGER,
agnCAgendaDayIdx INTEGER,
agnCAgendaDayCategory INTEGER
}
agnCAgendaCnfgIdx OBJECT-TYPE
SYNTAX INTEGER
{
active (1),
temporary (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Agenda Table.
Both configurations can be read but only the Temporary can
be written to."
::= {agnCAgendaEntry 1}
agnCAgendaDayIdx OBJECT-TYPE
SYNTAX INTEGER
{
sunday (1),
monday (2),
tuesday (3),
wednesday (4),
thursday (5),
friday (6),
saturday (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Day of week"
::= {agnCAgendaEntry 2}
agnCAgendaDayCategory OBJECT-TYPE
SYNTAX INTEGER
{
fullWorkday (1),
partialWorkday (2),
weekend (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Category of the Day "
::= {agnCAgendaEntry 3}
-- agnCFlipNetEventsTable :
--
agnCFlipNetEventsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCFlipNetEventsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table holds the Net Events the MUX should trace"
::= {agnFlipDb 2}
agnCFlipNetEventsEntry OBJECT-TYPE
SYNTAX AgnCFlipNetEventsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCFlipNetEventsCnfgIdx, agnCFlipNetEventIdx}
::= {agnCFlipNetEventsTable 1}
AgnCFlipNetEventsEntry ::=
SEQUENCE {
agnCFlipNetEventsCnfgIdx INTEGER,
agnCFlipNetEventIdx Integer32,
agnCFlipNetEventActive INTEGER,
agnCFlipNetEventType INTEGER,
agnCFlipNetEventNo Integer32,
agnCFlipNetEventSlot INTEGER,
agnCFlipNetEventPort Integer32,
agnCFlipNetEventISD Integer32,
agnCFlipNetEventOSD Integer32,
agnCFlipNetEventDayType INTEGER,
agnCFlipNetEventStartTime DisplayString,
agnCFlipNetEventEndTime DisplayString
}
agnCFlipNetEventsCnfgIdx OBJECT-TYPE
SYNTAX INTEGER
{
active (1),
temporary (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Net Events Table.
Both configurations can be read but only the Temporary can
be written to."
::= {agnCFlipNetEventsEntry 1}
agnCFlipNetEventIdx OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Entry within the table"
::= {agnCFlipNetEventsEntry 2}
agnCFlipNetEventActive OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if the entry is valid.
In order to Add/Modify parameters of an entry, this object
should be set to Yes.
In order to delete an entry, this object should be Set to No."
::= {agnCFlipNetEventsEntry 3}
agnCFlipNetEventType OBJECT-TYPE
SYNTAX INTEGER
{
time (1),
linkDown (2),
congestion (3) -- MP3000 Only
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Net Event type "
::= {agnCFlipNetEventsEntry 4}
agnCFlipNetEventNo OBJECT-TYPE
SYNTAX Integer32 (1..512)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Net Event No. (Bit Index)"
::= {agnCFlipNetEventsEntry 5}
agnCFlipNetEventSlot OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The slot to which the net event relates .
Not applicable for time event"
::= {agnCFlipNetEventsEntry 6}
agnCFlipNetEventPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port within the relevant slot.
Valid values:
- extPrt1(1)..exPrt16(16)
- notApplicable(100)
- inPrt1(101)..inPrt84(184)"
::= {agnCFlipNetEventsEntry 7}
agnCFlipNetEventISD OBJECT-TYPE
SYNTAX Integer32 (1..999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in seconds since the Net Event was reported as ON
until it is considered as ON.
Not relevant for time events."
::= {agnCFlipNetEventsEntry 8}
agnCFlipNetEventOSD OBJECT-TYPE
SYNTAX Integer32 (1..999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in seconds since the net event was reported as OFF
until it is considered as OFF.
Not relevant for time events."
::= {agnCFlipNetEventsEntry 9}
agnCFlipNetEventDayType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fullWorkday (2),
partialWorkday (3),
weekend (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time event relates to all days defined in this category in
the agnCAgendaTable.
Applicable only for time event"
::= {agnCFlipNetEventsEntry 10}
agnCFlipNetEventStartTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time event will be activated at this time.
The format is hh:mm."
::= {agnCFlipNetEventsEntry 11}
agnCFlipNetEventEndTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (5))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time event will be deactivated at this time.
The format is hh:mm."
::= {agnCFlipNetEventsEntry 12}
-- agnCFlipTable :
--
agnCFlipTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnCFlipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DB Flip Decisions Table"
::= {agnFlipDb 3}
agnCFlipEntry OBJECT-TYPE
SYNTAX AgnCFlipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnCFlipCnfgIdx, agnCFlipIdx}
::= {agnCFlipTable 1}
AgnCFlipEntry ::=
SEQUENCE {
agnCFlipCnfgIdx INTEGER,
agnCFlipIdx Integer32,
agnCFlipActive INTEGER,
agnCFlipLogicalExp DisplayString,
agnCFlipDbNo Integer32,
agnCFlipDiscardDe INTEGER
}
agnCFlipCnfgIdx OBJECT-TYPE
SYNTAX INTEGER
{
active (1),
temporary (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Flip Decisions Table.
Both configurations can be read but only the Temporary can
be written to."
::= {agnCFlipEntry 1}
agnCFlipIdx OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Entry number within the table"
::= {agnCFlipEntry 2}
agnCFlipActive OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates if the entry is valid.
In order to Add/Modify parameters of an entry this object
should be Set to Yes.
In order to delete an entry, this object should be Set to No."
::= {agnCFlipEntry 3}
agnCFlipLogicalExp OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A logical expression composed of events numbers (which were
configured in the 'AgnCFlipNetEvantsTable') and logical operators
('|', '&', '!', '(', ')') between them.
e.g - (1 & !2) | (121 & 230)"
::= {agnCFlipEntry 4}
agnCFlipDbNo OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ID of the required DB "
::= {agnCFlipEntry 5}
agnCFlipDiscardDe OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the Mux should start discarding
all DE. (MP3000 Only)."
::= {agnCFlipEntry 6}
-- Commands concerning the Flip DB
agnFlipDbControls OBJECT IDENTIFIER ::= {agnFlipDb 4}
agnCFlipDbSanityCheckCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on(3) will initiate the process
of Sanity check on the Temp Flip Db and automatically be
changed to off(2)."
::= { agnFlipDbControls 1 }
agnCSaveFlipDbCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on(3) will initiate the process
of Sanity check on the Temp Flip Db and if it is OK, it will
save the Flip Db in the NVRAM, activating the new Flip DB .
If check detects errors, the save will not be performed.
Afterwards, the object's value will change automatically to off(2)."
::= { agnFlipDbControls 2 }
agnCSaveNetCnfgIdxCmd OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute specifies the Id of the target NVRAM Cnfg to
which the TmpCnfg should be transferred. Upon set command the
MUX will initiate the Sanity-Check process first. If
successful, the actual transfer will be performed. If warnings
are detected, the user will have to perform the command again
to confirm the operation. Setting this object a second time
to the same value without performing any change in the database,
will cause the result: agnSSanityCheckStatus = unknown.
This attribute doesn't cause actual Flip."
::= { agnFlipDbControls 3 }
agnCSaveNetFlipDbCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on(3) will save the Temp Flip DB
Into the NVRAM without actual flip."
::= { agnFlipDbControls 4 }
agnCNetGoCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to On will broadcast a 'GO' command
to the network. When a Mux receives a 'GO' command it issues
a delay for 'agnCNetDelay' seconds and then activates
the DB which was pre-defined by one of the commands :
'agnCSaveNetCnfgIdxCmd' or 'agnCSaveNetFlipDbCmd'."
::= { agnFlipDbControls 5 }
agnCNetDelay OBJECT-TYPE
SYNTAX Integer32 (1..999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute determines the period of time in seconds that
takes for a message to be transferred over all the network.
After a 'GO' command the MUX issues a delay of
'agnCNetDelay' before activating the appropriate DB.
The delay will be applied only after performing
agnCSaveFlipDbCmd."
::= { agnFlipDbControls 6 }
agnCNetEventsBcast OBJECT-TYPE
SYNTAX INTEGER
{
disabled(2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines if the Net Events will be Broadcasted to
other Muxes of the Net or not.
disabled - Net Events will NOT be Broadcasted
enabled - Net Events will be Broadcasted.
Default=disabled.
The value will be applied only after performing
agnCSaveFlipDbCmd."
::= { agnFlipDbControls 7 }
agnCNetEventsBcastInterval OBJECT-TYPE
SYNTAX Integer32 (10..60)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When agnCNetEventsBcast is enabled, this object determines
the interval of time in seconds, between two consecutive
Net Events transferred over the network.
Default=40 sec.
The interval will be applied only after performing
agnCSaveFlipDbCmd."
::= { agnFlipDbControls 8 }
--
-- agnSa = agent Stand-Alone (not HUB) specific objects
--
agnSaSwchStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the status of the switches on the
stand-alone unit.
Each switch is represented by a bit. The status is a sum of
2**n, according to the bits:
bit 0 NMS (LSB)
bit 1 Terminal '1' = forces the DCE to be terminal with
Rate=9600bps, Data bits=8,
Stop bits=1
bit 2 Xray
bit 3 SW-Load '1' = when SW is loaded
bit 4 DBS
Default of all bits=0
When the status of these switches is unknown, the value of
this object is 255."
::= { agnSa 1 }
--Decoding Table: Code vs. Description
agnListDecodingTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnListDecodingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A decoding table . For each type of list, a description is
given for each existing code."
::= { agnListDecoding 1 }
agnListDecodingEntry OBJECT-TYPE
SYNTAX AgnListDecodingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnListDecodingType, agnListDecodingCode }
::= { agnListDecodingTable 1}
AgnListDecodingEntry ::=
SEQUENCE {
agnListDecodingType INTEGER,
agnListDecodingCode Integer32,
agnListDecodingDescription DisplayString,
agnListDecodingDefState INTEGER,
agnListDecodingSeverity INTEGER,
agnListDecodingAcmRelaySlt INTEGER,
agnListDecodingAcmRelayPrt INTEGER
}
agnListDecodingType OBJECT-TYPE
SYNTAX INTEGER
{
alr (1),
sanity (2),
counter (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of list the decoding data refers to.
alr - Alarms list
sanity - Sanity Check Error list.
counter - Counter type of ifPerfCounterType "
::= { agnListDecodingEntry 1}
agnListDecodingCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The specific code for which decoding is needed. "
::= { agnListDecodingEntry 2}
agnListDecodingDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description fitting the specific code and type of list
required. "
::= { agnListDecodingEntry 3}
agnListDecodingDefState OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is applicable only for agnListDecodingType=alr.
It reports the default state/severity of each alarm.
User can change the severity of the alarms defined by
this default via the agnListDecodingSeverity object."
::= { agnListDecodingEntry 4}
agnListDecodingSeverity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only for agnListDecodingType=alr.
It enables the user to select a severity for each alarm.
The severity is set per alarm code (same for all slots/ports
using this code).
event - can be set only for an alarm that is defined by
default as 'event'.
User can change the severity of the alarms defined by
default as minor or major.
The severity of an event may be set to another severity,
but the change will actually happen only if the event
threshold is active and passed the Set/ON condition.
An event alarm that passed the threshold and changed its
severity, will return automatically to event severity when
meeting its Reset/OFF condition."
::= { agnListDecodingEntry 5}
agnListDecodingAcmRelaySlt OBJECT-TYPE
SYNTAX INTEGER
{ none (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the ACM slot, desired for outbound relay
(report) for the selected alarm.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
none - when agnListDecodingType=alr AND the selected
alarm should not be reported by an ACM card.
notApplicable - when agnListDecodingType=sanity OR when
[agnListDecodingType=alr and there is no ACM card installed in the Mux]."
::= { agnListDecodingEntry 6}
agnListDecodingAcmRelayPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the ACM port within the slot, desired for outbound relay
(report) for the selected alarm.
notApplicable - when agnListDecodingType=sanity OR when
agnListDecodingAcmRelaySlt=notApplicable."
::= { agnListDecodingEntry 7}
-- Dlci Table from system point of view
agnDlciTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { agnSystemDlci 1}
agnDlciEntry OBJECT-TYPE
SYNTAX AgnDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnDlciCnfgIdx, agnDlciLSltIdx, agnDlciLPrtIdx, agnDlciHIdx,
agnDlciHSltIdx, agnDlciHPrtIdx, agnDlciLIdx }
::= { agnDlciTable 1}
AgnDlciEntry ::=
SEQUENCE {
agnDlciCnfgIdx Integer32,
agnDlciLSltIdx INTEGER,
agnDlciLPrtIdx Integer32,
agnDlciLIdx Integer32,
agnDlciHSltIdx INTEGER,
agnDlciHPrtIdx Integer32,
agnDlciHIdx Integer32,
agnDlciTxBc INTEGER,
agnDlciTxBe INTEGER,
agnDlciRxBc INTEGER,
agnDlciRxBe INTEGER,
agnDlciPriority Integer32,
agnDlciStatus INTEGER,
agnDlciSpoofing INTEGER,
agnDlciFunnelEnable INTEGER,
agnDlciRoutingProtocol INTEGER,
agnDlciRowStatus RowStatus
}
agnDlciCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { agnDlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
agnDlciLSltIdx OBJECT-TYPE
SYNTAX INTEGER
{ cl(3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
vs (254),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted. This is the Source Slot of the DLCI.
vs=Voice Switching
In the ?004 Unit the entries io6(10)..io16) are not valid.
For ISDN BRI ports of MX300/30 units:
io1(5) = isdn1(5) and io2(6) = isdn2(6)
LSlotIdx is defined according one of the following possiblities:
1. LSlotIdx is < HSlotIdx.
2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
::= { agnDlciEntry 2}
agnDlciLPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique external or internal port number,
including linkSelector or encapsulator. This is the Source Port of the DLCI.
100=noConnect (for voice switching)
LPrtIdx is defined according one of the following possiblities:
1. LSlotIdx is < HSlotIdx.
2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
::= { agnDlciEntry 3}
agnDlciLIdx OBJECT-TYPE
SYNTAX Integer32 (0..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique index for each possible
used DLCI(16..991). This is the Source Side of the DLCI.
0=notApplicable (for voice switching)
LIdx is defined according one of the following possiblities:
1. LSlotIdx is < HSlotIdx.
2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx.
3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx."
::= { agnDlciEntry 4}
agnDlciHSltIdx OBJECT-TYPE
SYNTAX INTEGER
{ cl (3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position In the Mux
where the DLCI is routed to - Destination Slot.
For ISDN BRI ports of MX300/30 units:
io1(5) = isdn1(5) and io2(6) = isdn2(6)
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { agnDlciEntry 5}
agnDlciHPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number where the DLCI is
routed to - Destination Port."
::= { agnDlciEntry 6}
agnDlciHIdx OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal connection DLCI
number where the Source DLCI is routed to - the Destination Side of the DLCI."
::= { agnDlciEntry 7}
agnDlciTxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBc5100bps (3),
txBc6400bps (4),
txBc8300bps (5),
txBc9600bps (6),
txBc14400bps (7),
txBc19200bps (8),
txBc28800bps (9),
txBc32000bps (10),
txBc38400bps (11),
txBc48000bps (12),
txBc56000bps (13),
txBc57600bps (14),
txBc64Kbps (15),
txBc128Kbps (16),
txBc192Kbps (17),
txBc256Kbps (18),
txBc320Kbps (19),
txBc384Kbps (20),
txBc448Kbps (21),
txBc512Kbps (22),
txBc768Kbps (23),
txBc896Kbps (24),
txBc1024Kbps (25),
txBc1152Kbps (26),
txBc1280Kbps (27),
txBc1344Kbps (28),
txBc1472Kbps (29),
txBc1600Kbps (30),
txBc1728Kbps (31),
txBc1856Kbps (32),
txBc1920Kbps (33),
txBc1984Kbps (34),
txBc2048Kbps (35),
txBc16000bps (36), -- Added here: No room between (7) and (8).
-- For Mx 30/300
txBc112Kbps (37),
txBc168Kbps (38),
txBc224Kbps (39),
txBc336Kbps (40),
txBc672Kbps (41),
txBc1536Kbps (42),
txBc1792Kbps (43)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx committed bandwidth on
the user transmit line or at the port receive line."
DEFVAL { full }
::= { agnDlciEntry 8}
agnDlciTxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBe5100bps (3),
txBe6400bps (4),
txBe8300bps (5),
txBe9600bps (6),
txBe14400bps (7),
txBe19200bps (8),
txBe28800bps (9),
txBe32000bps (10),
txBe38400bps (11),
txBe48000bps (12),
txBe56000bps (13),
txBe57600bps (14),
txBe64Kbps (15),
txBe128Kbps (16),
txBe192Kbps (17),
txBe256Kbps (18),
txBe320Kbps (19),
txBe384Kbps (20),
txBe448Kbps (21),
txBe512Kbps (22),
txBe768Kbps (23),
txBe896Kbps (24),
txBe1024Kbps (25),
txBe1152Kbps (26),
txBe1280Kbps (27),
txBe1344Kbps (28),
txBe1472Kbps (29),
txBe1600Kbps (30),
txBe1728Kbps (31),
txBe1856Kbps (32),
txBe1920Kbps (33),
txBe1984Kbps (34),
txBe2048Kbps (35),
txBe16000bps (36), -- Added here: No room between (7) and (8).
-- For Mx 30/300
txBe112Kbps (37),
txBe168Kbps (38),
txBe224Kbps (39),
txBe336Kbps (40),
txBe672Kbps (41),
txBe1536Kbps (42),
txBe1792Kbps (43)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx excess bandwidth on the
user transmit line or at the port receive line."
DEFVAL { zero }
::= { agnDlciEntry 9}
agnDlciRxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBc5100bps (3),
rxBc6400bps (4),
rxBc8300bps (5),
rxBc9600bps (6),
rxBc14400bps (7),
rxBc19200bps (8),
rxBc28800bps (9),
rxBc32000bps (10),
rxBc38400bps (11),
rxBc48000bps (12),
rxBc56000bps (13),
rxBc57600bps (14),
rxBc64Kbps (15),
rxBc128Kbps (16),
rxBc192Kbps (17),
rxBc256Kbps (18),
rxBc320Kbps (19),
rxBc384Kbps (20),
rxBc448Kbps (21),
rxBc512Kbps (22),
rxBc768Kbps (23),
rxBc896Kbps (24),
rxBc1024Kbps (25),
rxBc1152Kbps (26),
rxBc1280Kbps (27),
rxBc1344Kbps (28),
rxBc1472Kbps (29),
rxBc1600Kbps (30),
rxBc1728Kbps (31),
rxBc1856Kbps (32),
rxBc1920Kbps (33),
rxBc1984Kbps (34),
rxBc2048Kbps (35),
rxBc16000bps (36), -- Added here: No room between (7) and (8).
-- For Mx 30/300
rxBc112Kbps (37),
rxBc168Kbps (38),
rxBc224Kbps (39),
rxBc336Kbps (40),
rxBc672Kbps (41),
rxBc1536Kbps (42),
rxBc1792Kbps (43)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx committed bandwidth on
the user receive line or at the port transmit line."
DEFVAL { full }
::= { agnDlciEntry 10}
agnDlciRxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBe5100bps (3),
rxBe6400bps (4),
rxBe8300bps (5),
rxBe9600bps (6),
rxBe14400bps (7),
rxBe19200bps (8),
rxBe28800bps (9),
rxBe32000bps (10),
rxBe38400bps (11),
rxBe48000bps (12),
rxBe56000bps (13),
rxBe57600bps (14),
rxBe64Kbps (15),
rxBe128Kbps (16),
rxBe192Kbps (17),
rxBe256Kbps (18),
rxBe320Kbps (19),
rxBe384Kbps (20),
rxBe448Kbps (21),
rxBe512Kbps (22),
rxBe768Kbps (23),
rxBe896Kbps (24),
rxBe1024Kbps (25),
rxBe1152Kbps (26),
rxBe1280Kbps (27),
rxBe1344Kbps (28),
rxBe1472Kbps (29),
rxBe1600Kbps (30),
rxBe1728Kbps (31),
rxBe1856Kbps (32),
rxBe1920Kbps (33),
rxBe1984Kbps (34),
rxBe2048Kbps (35),
rxBe16000bps (36), -- Added here: No room between (7) and (8).
-- For Mx 30/300
rxBe112Kbps (37),
rxBe168Kbps (38),
rxBe224Kbps (39),
rxBe336Kbps (40),
rxBe672Kbps (41),
rxBe1536Kbps (42),
rxBe1792Kbps (43)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx excess bandwidth on the
user receive line or at the port transmit line."
DEFVAL { zero }
::= { agnDlciEntry 11}
agnDlciPriority OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique priority of the pcv.
1 is the lowest priority and 7 is the highest priority."
::= { agnDlciEntry 12}
agnDlciStatus OBJECT-TYPE
SYNTAX INTEGER
{
disconnected (1),
connected (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the pvc. The status is
disconnected(1) when one of the sides is programmed as
not connected"
::= { agnDlciEntry 13}
agnDlciSpoofing OBJECT-TYPE
SYNTAX INTEGER
{ no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object refers to sending of RIP messages:
- yes : RIP messages will be sent ONLY if there is a change in the Net.
- no : RIP messages will be always sent.
This object is relevant only when one side of the DLCI is a CL-NMS interface.
Default=no. "
::= { agnDlciEntry 14}
agnDlciFunnelEnable OBJECT-TYPE
SYNTAX INTEGER
{ disabled (2),
enabled (3),
source (4),
destination (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object selects Funnel activation:
- disabled: Funnel operation will be disabled.
The agnDlciTxBe and agnDlciTxBc values are not used for funneling.
- enabled : Funnel operation will be enabled both for Source and Destination
of the DLCI. The agnDlciTxBe and agnDlciTxBc values are used
for funneling calculations.
- source: Funnel operation will be enabled only for the Source of the DLCI.
- destination:Funnel operation will be enabled only for the Destination of the DLCI.
This object is relevant only for an encapsulating DLCI.
In case of a Link Selector DLCI, the agnDlciTxBe and agnDlciTxBc
values are used for bandwidth of Link Selector.
Default=disabled. "
::= { agnDlciEntry 15}
agnDlciRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER
{ notApplicable(1),
rip (2),
rip2(3),
none(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is relevant only when one side of the DLCI is a CL-NMS interface.
It defines which Routing Protocol will be used for management via CL-NMS port.
notApplicable will be used for all slots but CL.
rip is a proprietary rip protocol.
Default=rip. "
::= { agnDlciEntry 16}
agnDlciRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute allows to create/delete a row in this table.
For creating a row, the NMS should set
agnRowStatus.255.id2.id3.id4.id5.id6.id7 = active(1).
For destroying a row, the NMS should set:
agnRowStatus.255.id2.id3.id4.id5.id6.id7 = destroy(6).
Only rows with status active(1) are relevant.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { agnDlciEntry 17}
-- Voice Switching Configuration Support: agnVoiceSwitching group
agnVoiceSwConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnVoiceSwConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MXcess Configuration for Voice Switching."
::= { agnVoiceSwitching 1 }
agnVoiceSwConfEntry OBJECT-TYPE
SYNTAX AgnVoiceSwConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnVoiceSwConfIdx }
::= { agnVoiceSwConfTable 1}
AgnVoiceSwConfEntry ::=
SEQUENCE {
agnVoiceSwConfIdx INTEGER,
agnVoiceSwConfZoneId DisplayString,
agnVoiceSwConfNodeId DisplayString,
agnVoiceSwConfNoOfHops Integer32,
agnVoiceSwConfSidt Integer32,
agnVoiceSwConfLidt Integer32,
agnVoiceSwConfDialPlan INTEGER
}
agnVoiceSwConfIdx OBJECT-TYPE
SYNTAX INTEGER { active(1), temporary(255) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Table.
Both configurations can be read but only the Temporary can
be written to."
::= { agnVoiceSwConfEntry 1}
agnVoiceSwConfZoneId OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1 or 2 digits, (0-9)(1-9)."
::= { agnVoiceSwConfEntry 2}
agnVoiceSwConfNodeId OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..3))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"1, 2 or 3 digits, (1-9),(0-9),(0-9)."
::= { agnVoiceSwConfEntry 3}
agnVoiceSwConfNoOfHops OBJECT-TYPE
SYNTAX Integer32 (0..20)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Number of hops the frame will go through the net before deciding to discard
the frame (like time-to-live in IP).
0 = notApplicable
Default=20 ."
::= { agnVoiceSwConfEntry 4}
agnVoiceSwConfSidt OBJECT-TYPE
SYNTAX Integer32 (0..30)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SIDT: Short Inter Digit Timeout used as timer (in sec.) between digits
after routing is completed.
The timeout indicates end of dialing and the call can then be setup.
0 = notApplicable
Default=2 sec."
::= { agnVoiceSwConfEntry 5}
agnVoiceSwConfLidt OBJECT-TYPE
SYNTAX Integer32 (0..30)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"LIDT: Long Inter Digit Timeout used as timer between digits before routing
is completed. If no digits were dialed and LIDT expired then the user will get
an error tone and the call will be disconnected.
0 = notApplicable
Default=15 sec."
::= { agnVoiceSwConfEntry 6}
agnVoiceSwConfDialPlan OBJECT-TYPE
SYNTAX INTEGER {
staticDialPlan(2),
staticDialPlanPlus(3),
flexDialPlan(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the Dialing Plan method that will be used in the Voice Switching.
Static Dialing Plan - Routing is defined by the current device Zone and
Node ID in the Network.
Static Dialing Plan Plus - Includes the Static Dialing Plan but contains an
addition of defining the number of dialed digits.
Flexible Dialing Plan - Routing is defined in a flexible form.
In this plan the user can configure the extension number
of a local voice channel, Route a call to a remote
destination and enter the Number of Digits for a specific
dial prefix."
::= { agnVoiceSwConfEntry 7}
agnVoiceSwConfRtTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnVoiceSwConfRtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Routing Table for Voice Switching."
::= { agnVoiceSwitching 2 }
agnVoiceSwConfRtEntry OBJECT-TYPE
SYNTAX AgnVoiceSwConfRtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnVoiceSwConfRtDbId, agnVoiceSwConfRtIdx }
::= { agnVoiceSwConfRtTable 1}
AgnVoiceSwConfRtEntry ::=
SEQUENCE {
agnVoiceSwConfRtDbId INTEGER,
agnVoiceSwConfRtIdx Integer32,
agnVoiceSwConfRtDigits DisplayString,
agnVoiceSwConfRtAction INTEGER,
agnVoiceSwConfRtData DisplayString,
agnVoiceSwConfRtSlot INTEGER,
agnVoiceSwConfRtPort Integer32,
agnVoiceSwConfRtDlci Integer32,
agnVoiceSwConfRtRowStatus RowStatus,
agnVoiceSwConfRtMaxCalls Integer32,
agnVoiceSwConfRtPriority Integer32
}
agnVoiceSwConfRtDbId OBJECT-TYPE
SYNTAX INTEGER { active(1), temporary(255) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Table.
Both configurations can be read but only the Temporary can
be written to."
::= { agnVoiceSwConfRtEntry 1 }
agnVoiceSwConfRtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The Index of the row."
::= { agnVoiceSwConfRtEntry 2 }
agnVoiceSwConfRtDigits OBJECT-TYPE
SYNTAX DisplayString ( SIZE(1..7) )
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Dialed digits: Series of digits 0...9, '*', '#' or '%'.
The '*' and '#' can have many uses according to the user's decision.
For example, they can be used as part of the Dialed Number,
they exist on the phone number panel.
'*' can also be used instead of a series of numbers.
The '%' means any digits (wildcard) and is used without a series of digits.
When the agnVoiceSwConfRtAction is del (7), the series of digits that
are configured via this MIB object will be deleted from the prefix of
the dialed number."
::= { agnVoiceSwConfRtEntry 3 }
agnVoiceSwConfRtAction OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
zone(2),
node(3),
shortDialing(4),
in(5), -- Internal switching
hgr(6), -- Hunt Group
del(7), -- Delete a prefix from the Dialed Number
rep(8), -- Replace a prefix with a given string of digits
pri(9), -- for ISDN
bri(10),-- for ISDN
numDigDP(11), -- Number of Digits user will dial according to Dialing Plan.
route(12), -- Route to a Remote Destination
ext(13) -- Extension to a local voice channel
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Action that the system should perform for the digits:
agnVoiceSwConfRtDigits.
The action that is allowed depends on the Dialing Plan.
Here is the list of the allowed actions:
For Static Dialing Plan - zone, node, in, shortDialing, hgr, del, rep
For Static Dialing Plan Plus - zone, node, in, shortDialing, hgr, del, rep, numDigDP
For Flexible Dialing Plan - hgr, del, rep, numDigDP, route, ext"
DEFVAL { notApplicable }
::= { agnVoiceSwConfRtEntry 4 }
agnVoiceSwConfRtData OBJECT-TYPE
SYNTAX DisplayString(SIZE(1..7))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This field is relevant for actions hgr(6), and rep(8), numDigDP(11)
and contains the following information:
For hgr - the number of the Hunt Group.
For rep - the number of digits to be replaced with.
For numDigDP - the number of digits collected before establishing the call.
0 indicates no defined length. In this case SIDT will be used."
-- DEFVAL {"0" }
::= { agnVoiceSwConfRtEntry 5 }
agnVoiceSwConfRtSlot OBJECT-TYPE
SYNTAX INTEGER{
noConnect(2),
cl (3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Routing Slot- Relevant for actions zone(2), node(3), shortDialing(4),
route(12), ext(13)."
DEFVAL { noConnect }
::= { agnVoiceSwConfRtEntry 6 }
agnVoiceSwConfRtPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Routing Port- Relevant for actions zone(2), node(3), shortDialing(4),
route(12), ext(13).
100=noConnect (for non-routing case)."
DEFVAL { 0 }
::= { agnVoiceSwConfRtEntry 7 }
agnVoiceSwConfRtDlci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Routing DLCI- Relevant for actions zone(2), node(3), shortDialing(4),
route(12), ext(13).
Valid values:
0=notApplicable (for non-routing case).
1, 16..991 "
DEFVAL { 15 }
::= { agnVoiceSwConfRtEntry 8 }
agnVoiceSwConfRtRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" Status of the row for creating/deleting entries in the table.
The only possible supported RowStatus vaules are
active (1), notInService (2), notReady(3), createAndGo(4),
createAndWait(5) and destroy(6)."
::= { agnVoiceSwConfRtEntry 9 }
agnVoiceSwConfRtMaxCalls OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum no. of simultaneous voice calls that are allowed in the direction
defined by the current entry.
Default=0 (No Limit)."
::= { agnVoiceSwConfRtEntry 10}
agnVoiceSwConfRtPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates a unique priority of the Voice Switching Route.
1 is the lowest priority and 7 is the highest priority.
0 means N/A "
::= { agnVoiceSwConfRtEntry 11}
agnVoiceSwConfHGTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnVoiceSwConfHGEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of Hunt Groups."
::= { agnVoiceSwitching 5 }
agnVoiceSwConfHGEntry OBJECT-TYPE
SYNTAX AgnVoiceSwConfHGEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { agnVoiceSwConfHGdbIdx, agnVoiceSwConfHGIdx }
::= { agnVoiceSwConfHGTable 1}
AgnVoiceSwConfHGEntry ::=
SEQUENCE {
agnVoiceSwConfHGdbIdx INTEGER,
agnVoiceSwConfHGIdx Integer32,
agnVoiceSwConfHGConnect INTEGER,
agnVoiceSwConfHGExt Integer32,
agnVoiceSwConfHGExtString SnmpAdminString,
agnVoiceSwConfHGUserParams SnmpAdminString,
agnVoiceSwConfHGStatus INTEGER
}
agnVoiceSwConfHGdbIdx OBJECT-TYPE
SYNTAX INTEGER { active(1), temporary(255) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Active or Temporary Table.
Both configurations can be read but only the Temporary can
be written to."
::= { agnVoiceSwConfHGEntry 1}
agnVoiceSwConfHGIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For Vmux-300 devices -
This object represents a combination of
- Hunt Group number and Extension number OR
- Port number and Extension number.
For other devices (e.g. MXcess, MP-2100H) -
There may be up to 10 Hunt Groups per MXcess. That's the
index of the hunt group relevant to this row."
::= { agnVoiceSwConfHGEntry 2}
agnVoiceSwConfHGConnect OBJECT-TYPE
SYNTAX INTEGER { no(2), yes(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the hunt group should be
considered in any of the mux algorithms."
::= { agnVoiceSwConfHGEntry 3}
agnVoiceSwConfHGExt OBJECT-TYPE
SYNTAX Integer32(0..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the extension number of the hunt group.
0 is for not valid. The allowed range is 10 - 99."
DEFVAL { 0 }
::= { agnVoiceSwConfHGEntry 4}
agnVoiceSwConfHGExtString OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the extension string of the hunt group.
This string is a combination of digits, * and #."
::= { agnVoiceSwConfHGEntry 5}
agnVoiceSwConfHGUserParams OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the User's parameters."
::= { agnVoiceSwConfHGEntry 6}
agnVoiceSwConfHGStatus OBJECT-TYPE
SYNTAX INTEGER
{
active (1),
notInService (2),
notReady (3),
createAndGo (4),
createAndWait (5),
destroy (6),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables the user to create/delete entries in this table.
Its usage for values (1)..(6) should be identical to RowStatus SYNTAX.
notApplicable(255) - should be used when the table is static
(i.e. whenever create/delete entries is not allowed)."
::= { agnVoiceSwConfHGEntry 7}
--
-- Signaling Profiles for MP-2200 and MP-2100
--
-- Legacy Profile Table
agnSigProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSigProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"- For products supporting more than one configuration, the write operation
into the Table is valid only to the TmpCnfg entry.
- For products that do not support configurations, the write operation
into the Table will be to agnSigProfileCnfgIdx=1.
The table includes signaling profile parameters for Legacy Profiles."
::= { agnSigProfile 1}
agnSigProfileEntry OBJECT-TYPE
SYNTAX AgnSigProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnSigProfileCnfgIdx, agnSigProfileIdx, agnSigProfileRxTx}
::= { agnSigProfileTable 1}
AgnSigProfileEntry ::=
SEQUENCE {
agnSigProfileCnfgIdx Integer32,
agnSigProfileIdx Integer32,
agnSigProfileRxTx INTEGER,
agnSigProfileABCD OCTET STRING,
agnSigProfileEcanActSignal INTEGER,
agnSigProfileEcanRespDelay Unsigned32
}
agnSigProfileCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg.
For products supporting more than one configuration,the write
operation is valid only to the TmpCnfg.
For Gmux2000 the range limitation (1..255) was discarded
since the Idx is computed as: <IO Card No.> x 1000 + 255."
::= { agnSigProfileEntry 1}
agnSigProfileIdx OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Signaling Profile (1..5).
For MP-104/204, only Profile=1 will exist."
::= { agnSigProfileEntry 2}
agnSigProfileRxTx OBJECT-TYPE
SYNTAX INTEGER
{
rx (1),
tx (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates if the following objects refer to:
Rx or Tx translation.
Rx : ML->IO
Tx : IO->ML .
For MP-104/204, that means:
Rx : Signaling to FXS CH
Tx : Signaling to E1 Link. "
::= { agnSigProfileEntry 3}
agnSigProfileABCD OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For MP-2100/MP-2200 and for MP-104/204 from R2:
This object represents 6 parameters, by 3 Octets :
Busy Code-MSB nibble, - applicable only for Rx translation
Idle Code- nibble, - applicable only for Rx translation
D Bit Code- nibble,
C Bit Code- nibble,
B Bit Code- nibble,
A Bit Code-LSB nibble.
Each of Busy and Idle Code nibble will have the valid values:
0000 .. FFFF.
Each of A,B,C,D Bit Code nibble represents:
0 hex = 0000 = 0
1 hex = 0001 = 1
2 hex = 0010 = A bit
3 hex = 0011 = B bit
4 hex = 0100 = C bit
5 hex = 0101 = D bit
6 hex = 0110 = A bit inverse
7 hex = 0111 = B bit inverse
8 hex = 1000 = C bit inverse
9 hex = 1001 = D bit inverse
A-F hex - not used (invalid values)
For MP-104/204 R1:
This object represents 3 parameters, by 2 Octets :
Bit 1 = Bit A - OFF Hook for Tx ; Ring for Rx (LSB)
Bit 2 = Bit B - OFF Hook for Tx ; Ring for Rx
Bit 3 = Bit C - OFF Hook for Tx ; Ring for Rx
Bit 4 = Bit D - OFF Hook for Tx ; Ring for Rx
Bit 5 = Bit A - ON Hook for Tx ; Idle for Rx
Bit 6 = Bit B - ON Hook for Tx ; Idle for Rx
Bit 7 = Bit C - ON Hook for Tx ; Idle for Rx
Bit 8 = Bit D - ON Hook for Tx ; Idle for Rx
Bit 9 = Bit A - OOS State for both Tx and Rx
Bit 10 = Bit B - OOS State for both Tx and Rx
Bit 11 = Bit C - OOS State for both Tx and Rx
Bit 12 = Bit D - OOS State for both Tx and Rx
Bit 13 = Spare (always 0)
Bit 14 = Spare (always 0)
Bit 15 = Spare (always 0)
Bit 16 = Spare (always 0) (MSB)
When the object is not applicable, the Octet String will have 0 bytes."
::= { agnSigProfileEntry 4}
agnSigProfileEcanActSignal OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
aBit1 (2),
aBit0 (3),
bBit1 (4),
bBit0 (5),
cBit1 (6),
cBit0 (7),
dBit1 (8),
dBit0 (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo Canceller Activation Signal.
This object specifies which BIT (A, B, C, or D) and which value (0 or 1)
will be used for the echo canceller activation. The inverse value will cause the
deactivation of the echo canceller."
::= { agnSigProfileEntry 5}
agnSigProfileEcanRespDelay OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo Canceller Response Delay.
This object specifies the response delay in msec for the activation/deactivation
of the echo canceller.
The value should be in multiples of 100 msec: 100, 200, 300, ...2000."
::= { agnSigProfileEntry 6}
-- General Profile Table
agnSigProfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgnSigProfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry. This is the general table of signaling profiles."
::= { agnSigProfile 2}
agnSigProfEntry OBJECT-TYPE
SYNTAX AgnSigProfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {agnSigProfCnfgIdx, agnSigProfIdx}
::= { agnSigProfTable 1}
AgnSigProfEntry ::=
SEQUENCE {
agnSigProfCnfgIdx Integer32,
agnSigProfIdx Integer32,
agnSigProfName DisplayString,
agnSigProfType INTEGER
}
agnSigProfCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg.
The write operation is valid only to the TmpCnfg."
::= { agnSigProfEntry 1}
agnSigProfIdx OBJECT-TYPE
SYNTAX Integer32 (1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Signaling Profile (1..5)."
::= { agnSigProfEntry 2}
agnSigProfName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..12))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile Name given by user."
::= { agnSigProfEntry 3 }
agnSigProfType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
legacy (2),
r2Cas (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Profile Type.
legacy - usual signaling. The parameters for the Legacy Profiles
are detailed in the agnSigProfileTable, above.
r2Cas - R2 signaling. The parameters for the R2 Profiles are detailed
in the r2 ProfileCnfg tables (belong to r2If). "
::= { agnSigProfEntry 4 }
--
-- TS Assignment Table from system point of view
--
-- agnTsTable OBJECT-TYPE ::= { agnSystemTs 1}
--
-- For this table see tsa.txt file.
-- General System Voice parameters
--
systemVoiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemVoiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"General Parameters for voice - system level."
::= { systemVoice 1 }
systemVoiceEntry OBJECT-TYPE
SYNTAX SystemVoiceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { systemVoiceConfIdx }
::= { systemVoiceTable 1}
SystemVoiceEntry ::=
SEQUENCE {
systemVoiceConfIdx Integer32,
systemVoiceNationalTone INTEGER,
systemVoicePacketRate Unsigned32,
systemVoiceFaxSupport INTEGER,
systemVoiceFaxRate INTEGER,
systemVoiceModemSupport INTEGER,
systemVoiceCoderAndRate INTEGER,
systemVoiceEchoCanceler INTEGER,
systemVoiceTxGain Integer32,
systemVoiceDtmfRelayMethod INTEGER,
systemVoiceDtmfRelayRxPayloadType Unsigned32,
systemVoiceDtmfRelayPayloadTypeNeg INTEGER,
systemVoiceDtmfRelayTxPayloadType Unsigned32
}
systemVoiceConfIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed - Active or Temporary Configurations.
Idx 255 relates to the temporary TmpCnfg.
All configurations can be read but only the Temporary can
be written to."
::= { systemVoiceEntry 1}
systemVoiceNationalTone OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
usa (2),
australia (3),
brazil (4),
canada (5),
france (6),
germany (7),
israel (8),
mexico (9),
portugal (10),
russia (11),
spain (12),
unitedKingdom (13),
czech (14),
china (15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Tone Characteristics (Amplitude, Frequency, delays etc.).
These characteristics are defined according to the country."
::= { systemVoiceEntry 2}
systemVoicePacketRate OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the G.729 and G.711 Coders
transmitted Packet Rate in milliseconds."
::= { systemVoiceEntry 3}
systemVoiceFaxSupport OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
faxRelayT38 (3),
vbdPassThrou (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to Disable/Enable Fax support."
::= { systemVoiceEntry 4}
systemVoiceFaxRate OBJECT-TYPE
SYNTAX INTEGER
{
notConnected (1),
r4800bps (2),
-- reserved for r7200bps (3)
r9600bps (4),
-- reserved for r12000bps (5)
r14400bps (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Fax Rate limit.
It is irrelevant when Fax support is NA or disabled."
::= { systemVoiceEntry 5}
systemVoiceModemSupport OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
vbdV152 (3),
vbdPassThrou (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to Disable/Enable Modem support."
::= { systemVoiceEntry 6}
systemVoiceCoderAndRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
-- reserved for g7231r6300BPS (2)
-- reserved for g7231r5300BPS (3)
-- reserved for g729A8KBPS (4)
g711aLAW (5),
g711uLAW (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Coder and Rate for the Voice Compression."
::= { systemVoiceEntry 7}
systemVoiceEchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Echo Canceler activation."
::= { systemVoiceEntry 8}
systemVoiceTxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Transmit Gain (volume) in dB."
::= { systemVoiceEntry 9}
systemVoiceDtmfRelayMethod OBJECT-TYPE
SYNTAX INTEGER
{
rfc2833 (1),
sipInfo (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the DTMF Relay Method
that is used to transmit DTMF tones.
rfc2833(1) - inband DTMF relay according to RFC-2833.
sipInfo(2) - out of band DTMF relay using SIP INFO method."
::= { systemVoiceEntry 10}
systemVoiceDtmfRelayRxPayloadType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Rx Payload Type
for DTMF relay RTP packets.
It is relevant only when DTMF Relay Method is RFC-2833."
::= { systemVoiceEntry 11}
systemVoiceDtmfRelayPayloadTypeNeg OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether Payload Type Negotiation is used
(according to RFC-2833) or not.
It is relevant only when DTMF Relay Method is RFC-2833."
::= { systemVoiceEntry 12}
systemVoiceDtmfRelayTxPayloadType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Tx Payload Type
for DTMF relay RTP packets.
It is relevant only when the Payload Type Negotiation is disabled."
::= { systemVoiceEntry 13}
systemVoiceCoderTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemVoiceCoderEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Voice Coders table."
::= { systemVoice 2 }
systemVoiceCoderEntry OBJECT-TYPE
SYNTAX SystemVoiceCoderEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in Voice Coders table."
INDEX { systemVoiceCoderConfIdx, systemVoiceCoderPriority }
::= { systemVoiceCoderTable 1}
SystemVoiceCoderEntry ::=
SEQUENCE {
systemVoiceCoderConfIdx Unsigned32,
systemVoiceCoderPriority Unsigned32,
systemVoiceCoderCoderAndRate INTEGER
}
systemVoiceCoderConfIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The first index of the table.
This object might represent the Configuration Index (1..100) being accessed;
Index=255 relates to the TmpCnfg.
For devices with multiple configurations, Set is permitted to TmpCnfg(255) only.
Not-Applicable = 1."
::= { systemVoiceCoderEntry 1}
systemVoiceCoderPriority OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Coder's Priority."
::= { systemVoiceCoderEntry 2}
systemVoiceCoderCoderAndRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
g7231r6300BPS (2),
g7231r5300BPS (3),
g729A8KBPS (4),
g711aLAW (5),
g711uLAW (6),
none (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Coder and Rate for the Voice Compression."
::= { systemVoiceCoderEntry 3}
--
-- Wan installed module status general information
--
mdlSInstTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlSInstEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { statMdlGen 1 }
mdlSInstEntry OBJECT-TYPE
SYNTAX MdlSInstEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlSInstSltIdx }
::= { mdlSInstTable 1}
MdlSInstEntry ::=
SEQUENCE {
mdlSInstSltIdx INTEGER,
mdlSInstCardType INTEGER,
mdlSHwVersion DisplayString,
mdlSSwVersion DisplayString,
mdlSAlrStatus INTEGER,
mdlSAlrStatusAll INTEGER,
mdlSMaskedAlrStat INTEGER,
mdlSMaskedAlrStatAll INTEGER,
mdlSTstStatusAll INTEGER,
mdlSClearAlrCmd INTEGER,
mdlSClearAllAlrCmd INTEGER,
mdlSTemperature Integer32
}
mdlSInstSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify a slot position in the mux.
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
are not valid.
For the Vmux2100 Main Board clA (3) is used."
::= { mdlSInstEntry 1}
mdlSInstCardType OBJECT-TYPE
SYNTAX INTEGER
{
--
-- General types
--
unknown (1),
empty (2),
-- (3)..(7) are reserved ; they appear in the compress structure
acm (9), --alarm module
--
-- Power Supply Modules
--
ps60W (10),
ps100W (11),
-- (12)..(16) are reserved for the Programmed PS cards
ps (17),
--
-- Cl Modules
--
cl1 (20),
clEth (21),
cl2 (22),
cl2Eth (23),
cl3 (24),
cl3Eth (25),
cl1Clk (26), --CL1 with Station Clock (for LRS102)
--
-- Packet Cards of Megaplex
--
mPh1 (31),
mPh3 (32),
mPh1T1DSU (33),
mPh1T1CSU (34),
mPh1E1DSU (35),
mPh1E1LTU (36),
-- TDM Cards
mtmlFT1 (37),
mtmlFE1 (38),
mtmlH4E1 (39),
mtmlH4E12W (40),
mtmlH4T1 (41),
mtmlH4T12W (42),
mtHsh4E1 (43),
mtHsh4E12W (44),
mtHsh4T1 (45),
mtHsh4T12W (46),
mtmlH2E1 (47),
mtmlH2E12W (48),
mtmlH2T1 (49),
mtmlH2T12W (50),
hsh2E1 (51),
hsh2E12W (52),
hsh2T1 (53),
hsh2T12W (54),
mlIp (55),
mtml4Ip (56),
ml20N1 (57),
ml20N2 (58),
-- Packet Cards of Megaplex
mPl6 (60),
mPl3 (61),
-- VF cards of Megaplex
vf24T1 (62),
vf30E1 (63),
vf48T1 (64),
vf60E1 (65),
-- Vmux-2100 Main Link cards
ml2E1 (68),
ml4E1 (69),
ml2T1 (70),
ml4T1 (71),
mPv4 (72),
--
-- TDM Cards
--
vc16A (73),
vc8EandM (74),
vc8Fxo (75),
vc8Fxs (76),
vc16EandM (77),
vc16Fxo (78),
vc16Fxs (79),
vf3EandM (80),
vf3Fxs (81),
vf3Fxo (82),
vfPbx (83),
vfPbxT1 (84),
vfPbxE1 (85),
mtMlE2S (86), --Single Link
mtMlE2D (87), --Dual Link
mtMlF2T1 (88),
mtMlF2E1 (89),
mtMlT1Fiber (90),
mtMlE1Fiber (91),
mtMlT1FiberFb (92),
mtMlE1FiberFb (93),
mtmlHE1 (94),
mtmlH1E1 (95),
mtmlHSE1 (96),
ml20 (97),
mtMl4T1 (98),
mtMl4E1 (99),
mtMl1T1DSU (100),
mtMl1T1CSU (101),
mtMl1E1DSU (102),
mtMl1E1LTU (103),
mtMl1T1DSUfb (104),
mtMl1T1CSUfb (105),
mtMl1E1DSUfb (106),
mtMl1E1LTUfb (107),
mtMl2T1 (108),
mtMl2E1 (109),
ls2CcittX50 (110),
ls2CcittX58 (111),
ls2ATandTSdm (112),
ls2ACcittX50 (113),
ls2ACcittX58 (114),
ls2AATandTSdm (115),
ls2A2Ts (116),
ls2M (117),
mtMlT1 (118),
mtMlE1 (119),
hs2 (120),
hs3 (121),
hsq (122),
hs703 (123),
hsQM (124),
hsqN (125),
hs6 (126),
hs12 (127),
hsDp (128),
hsp (129),
hs4T1 (130),
hs4E1 (131),
hs4 (132),
hsEth (133),
ml8T1 (134),
ml8E1 (135),
-- Vmux-2100 Voice cards
vc2E1 (136),
vc4E1 (137),
vc2T1 (138),
vc4T1 (139),
vc2EandM (140),
vc2Fxs1Plar (141),
vc2Fxo1 (142),
vc2Fxs2 (143),
vc2Fxo2 (144),
vc2Fxs3 (145),
vc2Fxo3 (146),
vc26EandM (147),
mtvc2 (148),
vc2R2Fxs (149),
hsu (150),
mbeA (151),
mbeB (152),
mbeU (153),
tre (154),
hsuI (155),
hsr (156),
hss (157),
hsu1 (158),
ls12 (159),
ls6 (160),
ls6V1EandM (161),
ls6V1Fxo (162),
ls6V1Fxs (163),
ls6V2EandM (164),
ls6V2Fxo (165),
ls6V2Fxs (166),
ls6VfEandM (167),
ls6VfFxo (168),
ls6VfFxs (169),
vc3EandM (170),
vc3Fxo (171),
vc3Fxs (172),
vcPbx (173),
vcPbxT1 (174),
vcPbxE1 (175),
vc6EandM (176),
vc6Fxo (177),
vc6Fxs (178),
vcq (179),
ls6n (180),
--
-- Packet Cards of MAXcess and Hybrid
--
-- High speed cards
mhs1V36 (181),
mhs1V35 (182),
mhs1G703 (183),
mhs1DDS (184),
mhs3 (185),
mhs1X21 (186),
mhs1V24 (187),
mhs4 (188),
mhsE1Hs (189),
mhsT1Hs (190),
mhsHyE1Hs (191), -- 2 HS ports + 1 Hybrid E1 port
mhsHyT1Hs (192), -- 2 HS ports + 1 Hybrid T1 port
mlfHybE1Hs (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port
mlfHybT1Hs (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port
-- T1/E1 cards
mhs2e1 (195),
mhs2t1 (196),
mhsHy2e1 (197), -- 2 Hybrid E1 ports
mhsHy2t1 (198), -- 2 Hybrid T1 ports
mlfHybE12 (199), -- Fiber Optic Hybrid: 2 E1 ports
-- Low speed cards
mls6 (200),
mls3 (201),
-- More T1/E1 cards
mlHybAtmE1 (202), -- Hybrid ATM E1
mlHybAtmT1 (203), -- Hybrid ATM T1
mlfHybT12 (204), -- Fiber Optic Hybrid: 2 T1 ports
-- Voice cards
mvc8 (205), -- MVC-8 name in marketing: MVC-4N
mvc8PbxE1 (206),
mvc8PbxT1Dsu (207),
mvc8PbxT1Csu (208),
mvc8PbxE1Slave (209),
mvc4 (210),
mvc4PbxE1 (211),
mvc4PbxT1Dsu (212),
mvc4PbxT1Csu (213),
mvc4PbxE1Slave (214),
mvc4PbxT1Slave (215),
mvc8PbxT1Slave (216), -- MVC-8 T1 Slave is here
mvc8ExtAnalog (217), -- MVC-8 with 8 External ports
mvcE1 (218), -- 8 External ports & 30 Internals
mvcT1 (219), -- 8 External ports & 24 Internals
-- ISDN for Maxcess
mhsS (220),
mhsU (221),
mhsPriE1 (222),
mhsPriT1 (223),
--Card of MP-2100/4
hsEthSwitch (224),
-- CCS for Maxcess & MPH
mPriE1FramerCcs (225),
mPriT1FramerCcs (226),
mPriE1SlaveCcs (227),
mPriT1SlaveCcs (228),
mDualBri (229),
--Voice cards for MP
vc12EandM (230),
vc12Fxo (231),
vc12Fxs (232),
vc6aEandM (233),
vc6aFxo (234),
vc6aFxs (235),
vc6AgFxo (236),
vc6AgFxs (237),
vc6a4LB (238),
--Video card for MP
vid (239),
--ISDN cards for MP
hsu12 (240),
hsu6 (241),
hss12 (242),
hss6 (243),
-- MPH and MP-2100/4 cards
hsDp3 (244),
hsDp6 (245),
-- MP-2100/4 card
hsf1 (246),
-- More Hybrid cards + IP cards for MPH
mhsHyE1 (247), -- 1 Hybrid E1 port
mhsHyT1 (248), -- 1 Hybrid T1 port
mhsIp (249), -- 1 Eth port + 1 HS port
mlIpHs (250), -- 1 Eth port + 3 HS ports
mlHybIpE1 (251), -- 1 Eth port + 1 HS port + 1 E1
mlHybIpT1 (252), -- 1 Eth port + 1 HS port + 1 T1
-- VOIP cards for MPH & MX
mvg1Lan (253),
mvg2Lan (254),
-- MP-2100/4 card
vc4Fxs (255),
vc4EandM (256),
vc4Fxo (257),
hsf2 (258),
-- More VOIP cards for MPH
mvgSwitch4Lan (260),
--SHDSL cards of Megaplex
msl4E1W2 (261),
msl4E1W4 (262),
msl8E1W2 (263),
msl4E1W2Eth (264),
msl8E1W2Eth (265),
asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH)
asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH)
asmi54c (268), -- & LRS-102 (ETH only)
--HS cards of Megaplex
hs6N (271),
hs12N (272),
hsNRZ (273),
-- Vmux 2100 Enhanced Voice Cards
evc2E1 (281),
evc4E1 (282),
evc2T1 (283),
evc4T1 (284),
-- Vmux-2200 Voice cards
vc2E1Pri (285),
vc4E1Pri (286),
-- MP Voice cards
vc4OmniEandM (291),
vc4OmniWestern (292),
-- MP-4100 and/or LRS-102 cards
clx1 (301),
clx1GbE (302),
clx1S155 (303),
clx1S155GbE (304),
ml8T1Eth (305),
ml8E1Eth (306),
op106cEth (307), --no external T1
op108cEth (308), --no external E1
op106cEthT1 (309), --with external T1 (used also by LRS-102)
op108cEthE1 (310), --with external E1 (used also by LRS-102)
op108cEthE1Unbal (311), --used only by LRS-102
mpw1 (312),
-- VFS cards of Megaplex
vfs24T1 (321),
vfs30E1 (322),
vfs48T1 (323), --2T1
vfs60E1 (324), --2E1
-- MiniCVS cards
mm4E1 (325),
mm4T1 (326),
mm8E1 (327),
mm8T1 (328),
mm12E1 (329),
mm12T1 (330),
mm16E1 (331),
mm16T1 (332)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the type of card installed
in the specific slot position.
Only PS cards are possible in the PS slots.
Only CL cards are possible in the CL slots.
Only IO cards are possible in the IO slots."
::= { mdlSInstEntry 2}
mdlSHwVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Hardware version of the
installed card in the specific slot position."
::= { mdlSInstEntry 3 }
mdlSSwVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Software version of the
installed card in the specific slot position."
::= {mdlSInstEntry 4}
mdlSAlrStatus OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state at module level, i.e. lower level
(port alarms) status is not included.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { mdlSInstEntry 5 }
mdlSAlrStatusAll OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the module-all level, i.e. lower level
(port alarms) included.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { mdlSInstEntry 6 }
mdlSMaskedAlrStat OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state at module level, [i.e. lower level
(port alarms) status is not included],including Masked alarms.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { mdlSInstEntry 7 }
mdlSMaskedAlrStatAll OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the module-all level, i.e. lower level
(port alarms) included, including Masked alarms.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { mdlSInstEntry 8 }
mdlSTstStatusAll OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute will be set to on(3) when there is at least
one test in progress on a channel of the card, otherwise
the value will be off(2)."
::= { mdlSInstEntry 9 }
mdlSClearAlrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this command to ON, enforces a clear of all the
alarms in the given slot, excluding alarms of port level.
The clear operation will not be applied for masked/inverted
alarms."
::= { mdlSInstEntry 10 }
mdlSClearAllAlrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this command to ON, enforces a clear of all the
alarms in the given slot, including all its ports alarms.
The clear operation will not be applied for masked/inverted
alarms."
::= { mdlSInstEntry 11 }
mdlSTemperature OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature of the card, in Celsius degrees."
::= { mdlSInstEntry 12 }
mdlSAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of card agent alarms ; includes also an alarm
indicating existence of alarms on its ports if there are any."
::= { statMdlGen 2 }
mdlSAlrEntry OBJECT-TYPE
SYNTAX MdlSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {mdlSAlrSltIdx , mdlSAlrIdx}
::= { mdlSAlrTable 1}
MdlSAlrEntry ::=
SEQUENCE {
mdlSAlrSltIdx INTEGER,
mdlSAlrIdx Integer32,
mdlSAlrCodeDescription DisplayString,
mdlSAlrCode Integer32,
mdlSAlrSeverity INTEGER,
mdlSAlrState INTEGER,
mdlSAlrCounter Integer32,
mdlSAlrMask INTEGER,
mdlSAlrInvert INTEGER
}
mdlSAlrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table.
Users should use the get next function to read this table because
the indexes are not consecutive."
::= { mdlSAlrEntry 1}
mdlSAlrSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the desired slot position.
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16)
are not valid.
For the Vmux2100 Main Board clA (3) is used."
::= { mdlSAlrEntry 2}
mdlSAlrCodeDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a full text description of the alarm .
The alarm description includes the following information:
alarm code, alarm text, alarm severity, Masked or Inverted
flag and counter."
::= { mdlSAlrEntry 3}
mdlSAlrCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A code identifying the alarm of an entry in the alarm status
table at card level."
::= { mdlSAlrEntry 4 }
mdlSAlrSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm."
::= { mdlSAlrEntry 5 }
mdlSAlrState OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the alarm."
::= { mdlSAlrEntry 6 }
mdlSAlrCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A counter - how many times the alarm occured since last
clear operation.
ON and OFF Alarm will be counted separately."
::= { mdlSAlrEntry 7 }
mdlSAlrMask OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm mask : on/off."
::= { mdlSAlrEntry 8 }
mdlSAlrInvert OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm invert : on/off."
::= { mdlSAlrEntry 9 }
--
-- Wan module configuration information
--
mdlCPrgTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlCPrgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cnfgMdlGen 1 }
mdlCPrgEntry OBJECT-TYPE
SYNTAX MdlCPrgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlCCnfgIdx, mdlCSltIdx }
::= { mdlCPrgTable 1}
MdlCPrgEntry ::= SEQUENCE {
mdlCCnfgIdx Integer32,
mdlCSltIdx INTEGER,
mdlCPrgCardType INTEGER,
mdlCNoOfExternPrt Integer32, -- RO
mdlCNoOfInternPrt Integer32, -- RO
mdlCWorkMode INTEGER,
mdlCDhcpClientEnable INTEGER,
mdlCRdnExists INTEGER, -- RO
mdlCInterfaces OCTET STRING
}
mdlCCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..100) being
referred.
Value 255 specifies the TmpCnfg "
::= { mdlCPrgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
mdlCSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number of the slot
position where the card is inserted.
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
are not valid."
::= { mdlCPrgEntry 2}
mdlCPrgCardType OBJECT-TYPE
SYNTAX INTEGER
{
--
-- General types
--
unknown (1),
empty (2),
-- (3)..(7) are reserved ; they appear in the compress structure
acm (9), --alarm module
--
-- Power Supply Modules
--
ps48x60W (10),
ps48x100W (11),
ps110x60W (12),
ps110x100W (13),
ps220x60W (14),
ps220x100W (15),
ps180W (16),
ps (17),
--
-- Cl Modules
--
cl1 (20),
clEth (21),
cl2 (22),
cl2Eth (23),
cl3 (24),
cl3Eth (25),
cl1Clk (26), --CL1 with Station Clock (for LRS102)
--
-- Packet Cards of Megaplex
--
mPh1 (31),
mPh3 (32),
mPh1T1DSU (33),
mPh1T1CSU (34),
mPh1E1DSU (35),
mPh1E1LTU (36),
-- TDM Cards
mtmlFT1 (37),
mtmlFE1 (38),
mtmlH4E1 (39),
mtmlH4E12W (40),
mtmlH4T1 (41),
mtmlH4T12W (42),
mtHsh4E1 (43),
mtHsh4E12W (44),
mtHsh4T1 (45),
mtHsh4T12W (46),
mtmlH2E1 (47),
mtmlH2E12W (48),
mtmlH2T1 (49),
mtmlH2T12W (50),
hsh2E1 (51),
hsh2E12W (52),
hsh2T1 (53),
hsh2T12W (54),
mlIp (55),
mtml4Ip (56),
ml20N1 (57),
ml20N2 (58),
-- Packet Cards of Megaplex
mPl6 (60),
-- mPl3 (61),
-- VF cards of Megaplex
vf24T1 (62),
vf30E1 (63),
vf48T1 (64),
vf60E1 (65),
-- Vmux-2100 Main Link cards
ml2E1 (68),
ml4E1 (69),
ml2T1 (70),
ml4T1 (71),
-- mPv4 (72),
--
-- TDM Cards
--
vc16A (73),
vc8EandM (74),
vc8Fxo (75),
vc8Fxs (76),
vc16EandM (77),
vc16Fxo (78),
vc16Fxs (79),
vf3EandM (80),
vf3Fxs (81),
vf3Fxo (82),
vfPbx (83),
vfPbxT1 (84),
vfPbxE1 (85),
mtMlE2S (86), --Single Link
mtMlE2D (87), --Dual Link
mtMlF2T1 (88),
mtMlF2E1 (89),
mtMlT1Fiber (90),
mtMlE1Fiber (91),
mtMlT1FiberFb (92),
mtMlE1FiberFb (93),
mtmlHE1 (94),
mtmlH1E1 (95),
mtmlHSE1 (96),
ml20 (97),
mtMl4T1 (98),
mtMl4E1 (99),
mtMl1T1DSU (100),
mtMl1T1CSU (101),
mtMl1E1DSU (102),
mtMl1E1LTU (103),
mtMl1T1DSUfb (104),
mtMl1T1CSUfb (105),
mtMl1E1DSUfb (106),
mtMl1E1LTUfb (107),
mtMl2T1 (108),
mtMl2E1 (109),
ls2CcittX50 (110),
ls2CcittX58 (111),
ls2ATandTSdm (112),
ls2ACcittX50 (113),
ls2ACcittX58 (114),
ls2AATandTSdm (115),
ls2A2Ts (116),
ls2M (117),
mtMlT1 (118),
mtMlE1 (119),
hs2 (120),
hs3 (121),
hsq (122),
hs703 (123),
hsQM (124),
hsqN (125),
hs6 (126),
hs12 (127),
hsDp (128),
hsp (129),
hs4T1 (130),
hs4E1 (131),
-- hs4 (132),
hsEth (133),
ml8T1 (134),
ml8E1 (135),
-- Vmux-2100 Voice cards
vc2E1 (136),
vc4E1 (137),
vc2T1 (138),
vc4T1 (139),
vc2EandM (140),
vc2Fxs1Plar (141),
vc2Fxo1 (142),
vc2Fxs2 (143),
vc2Fxo2 (144),
vc2Fxs3 (145),
vc2Fxo3 (146),
vc26EandM (147),
mtvc2 (148),
vc2R2Fxs (149),
hsu (150),
mbeA (151),
mbeB (152),
mbeU (153),
tre (154),
hsuI (155),
hsr (156),
hss (157),
hsu1 (158),
ls12 (159),
ls6 (160),
ls6V1EandM (161),
ls6V1Fxo (162),
ls6V1Fxs (163),
ls6V2EandM (164),
ls6V2Fxo (165),
ls6V2Fxs (166),
ls6VfEandM (167),
ls6VfFxo (168),
ls6VfFxs (169),
vc3EandM (170),
vc3Fxo (171),
vc3Fxs (172),
vcPbx (173),
vcPbxT1 (174),
vcPbxE1 (175),
vc6EandM (176),
vc6Fxo (177),
vc6Fxs (178),
vcq (179),
ls6n (180),
--
-- Packet Cards of Maxcess and Hybrid
--
-- High speed cards
mhs1V36 (181),
mhs1V35 (182),
mhs1G703 (183),
mhs1DDS (184),
mhs3 (185),
mhs1X21 (186),
mhs1V24 (187),
mhs4 (188),
mhsE1Hs (189),
mhsT1Hs (190),
mhsHyE1Hs (191), -- 2 HS ports + 1 Hybrid E1 port
mhsHyT1Hs (192), -- 2 HS ports + 1 Hybrid T1 port
mlfHybE1Hs (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port
mlfHybT1Hs (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port
-- T1/E1 cards
mhs2e1 (195),
mhs2t1 (196),
mhsHy2e1 (197), -- 2 Hybrid E1 ports
mhsHy2t1 (198), -- 2 Hybrid T1 ports
mlfHybE12 (199), -- Fiber Optic Hybrid: 2 E1 ports
-- Low speed cards
mls6 (200),
mls3 (201),
-- More T1/E1 cards
mlHybAtmE1 (202), -- Hybrid ATM E1
mlHybAtmT1 (203), -- Hybrid ATM T1
mlfHybT12 (204), -- Fiber Optic Hybrid: 2 T1 ports
-- Voice cards
mvc8 (205), -- MVC-8 name in marketing: MVC-4N
mvc8PbxE1 (206),
mvc8PbxT1Dsu (207),
mvc8PbxT1Csu (208),
mvc8PbxE1Slave (209),
mvc4 (210),
mvc4PbxE1 (211),
mvc4PbxT1Dsu (212),
mvc4PbxT1Csu (213),
mvc4PbxE1Slave (214),
mvc4PbxT1Slave (215),
mvc8PbxT1Slave (216), -- MVC-8 T1 Slave is here
mvc8ExtAnalog (217), -- MVC-8 with 8 External ports
mvcE1 (218), -- 8 External ports & 30 Internals
mvcT1 (219), -- 8 External ports & 24 Internals
-- ISDN for Maxcess
mhsS (220),
mhsU (221),
mhsPriE1 (222),
mhsPriT1 (223),
-- Card of MP-2100/4
hsEthSwitch (224),
-- CCS for Maxcess & MPH
mPriE1FramerCcs (225),
mPriT1FramerCcs (226),
mpriE1SlaveCcs (227),
mpriT1SlaveCcs (228),
mDualBri (229),
-- Voice cards for MP
vc12EandM (230),
vc12Fxo (231),
vc12Fxs (232),
vc6aEandM (233),
vc6aFxo (234),
vc6aFxs (235),
vc6AgFxo (236),
vc6AgFxs (237),
vc6a4LB (238),
-- Video card for MP
vid (239),
-- ISDN cards for MP
hsu12 (240),
hsu6 (241),
hss12 (242),
hss6 (243),
-- MPH and MP-2100/4 cards
hsDp3 (244),
hsDp6 (245),
-- MP-2100/4 card
hsf1 (246),
-- More Hybrid cards + IP cards for MPH
mhsHyE1 (247), -- 1 Hybrid E1 port
mhsHyT1 (248), -- 1 Hybrid T1 port
mhsIp (249), -- 1 Eth port + 1 HS port
mlIpHs (250), -- 1 Eth port + 3 HS ports
mlHybIpE1 (251), -- 1 Eth port + 1 HS port + 1 E1
mlHybIpT1 (252), -- 1 Eth port + 1 HS port + 1 T1
-- VOIP cards for MPH & MX
mvg1Lan (253),
mvg2Lan (254),
-- MP-2100/4 card
vc4Fxs (255),
vc4EandM (256),
vc4Fxo (257),
hsf2 (258),
-- More VOIP cards for MPH
mvgSwitch4Lan (260),
-- SHDSL cards of Megaplex
msl4E1W2 (261),
msl4E1W4 (262),
msl8E1W2 (263),
msl4E1W2Eth (264),
msl8E1W2Eth (265),
asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH)
asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH)
asmi54c (268), -- & LRS-102 (ETH only)
-- HS cards of Megaplex
hs6N (271),
hs12N (272),
hsNRZ (273),
-- Vmux 2100 Enhanced Voice Cards
evc2E1 (281),
evc4E1 (282),
evc2T1 (283),
evc4T1 (284),
-- Vmux-2200 Voice cards
vc2E1Pri (285),
vc4E1Pri (286),
-- MP Voice cards
vc4OmniEandM (291),
vc4OmniWestern (292),
-- MP-4100 and/or LRS-102 cards
clx1 (301),
clx1GbE (302),
clx1S155 (303),
clx1S155GbE (304),
ml8T1Eth (305),
ml8E1Eth (306),
op106cEth (307), -- no external T1
op108cEth (308), -- no external E1
op106cEthT1 (309), -- with external T1 (used also by LRS-102)
op108cEthE1 (310), -- with external E1 (used also by LRS-102)
op108cEthE1Unbal (311), -- used only by LRS-102
mpw1 (312),
op34c (313), -- no external E1
op25c (314), -- no external T1
op34cE1 (315), -- with external E1 (used also by LRS-102)
op25cT1 (316), -- with external T1 (used also by LRS-102)
m16e1 (317),
m16t1 (318),
op108cE1Unbal (319), -- used only by LRS-102
op108cE1Bal (320), -- used only by LRS-102.
-- VFS cards of Megaplex
vfs24T1 (321),
vfs30E1 (322),
vfs48T1 (323), -- 2T1
vfs60E1 (324), -- 2E1
-- MiniCVS cards: This is a placeholder. The following cards exist only in the mdlSInstCardType.
-- mm4E1 (325),
-- mm4T1 (326),
-- mm8E1 (327),
-- mm8T1 (328),
-- mm12E1 (329),
-- mm12T1 (330),
-- mm16E1 (331),
-- mm16T1 (332),
-- More MP-4100 / LRS-102 SDHSL Cards
asmi54cE1N (340), -- E1 only New Hardware
asmi54cN (341), -- ETH only New Hardware
asmi54cHsN (342), -- V.35 only (HighSpeed) New Hardware
asmi54cHsAndEthN (343), -- ETH & V.35 (HighSpeed) New Hardware
-- MP4100 R3.0 cards
cl2n (350), -- CL.2
cl2GbE (351), -- CL.2-GbE
cl2s622 (352), -- CL.2-622
cl2s622GbE (353), -- CL.2-622GbE
cl2s622GbEa (354), -- CL.2-622GbE/a with Advanced ETH features
cl2GbEa (355), -- CL.2-GbE a with Advanced ETH features
cl2ds0 (356), -- CL.2 with DS0 cross connect capabilities only
-- MP4104 cards (horizontal , low cost hub, lowprofile panels )
cl2nl (360), -- CL.2
cl2GbEl (361), -- CL.2-GbE
cl2s622l (362), -- CL.2-622
cl2s622GbEl (363), -- CL.2-622GbE
cl2s622GbEal (364), -- CL.2-622GbE/a with Advanced ETH features
cl2GbEal (365), -- CL.2-GbE a with Advanced ETH features
cl2ds0l (366), -- CL.2 with DS0 cross connect capabilities only
-- MP4100 R3.1 cards
mEth6 (370), -- M-ETH6 Card
mEth8 (371), -- M-ETH8 Card
-- TeleProtection Module
mTp (372), -- TeleProtection module
-- MP4100 R3.4 cards
mT3 (373), -- M-T3 DS3
mEthPoe (374), -- M-ETH8 with Power Over Ethernet support.
-- MP4100 R4.5 cards
-- X Module based cards
mp4mSh16 (381), -- MP-4M-SH-16
mp4mVs12 (382), -- MP-4M-VS-12
mp4mVs6s37 (383), -- MP-4M-VS-6/37
mp4mVs6Bin (384), -- MP-4M-VS-6/BIN
mp4mVs6E1T1 (385), -- MP-4M-VS-6/E1T1
mp4mE1T1 (386), -- MP-4M-E1T1
mp4mT3 (387), -- MP-4M-T3
mp4mVs6Fxs (388), -- MP-4M-VS6-FXS
mp4mVs6Fxo (389), -- MP-4M-VS6-FXO
mp4mVs6Em (390), -- MP-4M-VS6-EM
mp4mFxsEm (391), -- MP-4M-FXS-EM
-- MP4100 R4.7 cards
mp4mshE1 (392), -- MP-4M-SH-E1
mp4mshE1Pw (393), -- MP-4M-SH-E1-PW
mp4mvs16E1Eop (394), -- MP-4M-VS-16E1/EOP
mp4mvs16T1Eop (395), -- MP-4M-VS-16T1/EOP
mp4mvs16E1Pw (396), -- MP-4M-VS-16E1/PW
mp4mvs16T1Pw (397), -- MP-4M-VS-16T1/PW
mp4mvs6S8E1Pw (398), -- MP-4M-VS-6S/8E1/PW
mp4mvs6S8T1Pw (399), -- MP-4M-VS-6S/8T1/PW
-- Virtual Entity ( x.86 Module )
mp4mDnfv1 (401), -- MP-4M-DNFV-1 virtual entity (X.86 module)
--MP4100 R4.9 cards
mp4mvsG703 (411), -- MP-4M-VS-G703
mp4mVs6FxsPwAcr (412), -- MP-4M-VS6-FXS-PW-ACR
mp4mVs6FxoPwAcr (413), -- MP-4M-VS6-FXO-PW-ACR
mp4mVs6EmPwAcr (414) -- MP-4M-VS6-EM-PW-ACR
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the type of card assigned to the
specific slot in the common configuration.
This object is identical in all the configurations (1..100).
Only the TmpCnf(255) may have different value.
The write operation is valid only to the TmpCnfg entry."
::= { mdlCPrgEntry 3}
mdlCNoOfExternPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of external ports in the programmed card of the
specific slot position"
::= { mdlCPrgEntry 4}
mdlCNoOfInternPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of internal ports in the programmed card of the
specific slot position."
::= { mdlCPrgEntry 5}
mdlCWorkMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
standAlone (2),
integrated (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Working mode of the card.
The user may configure the card to work in a stand alone mode or integrated
with the device.
Example for use in MHS-IP cards:
- standAlone - in this mode, the router works so that data is received
via the LAN (Eth) port and is transmitted via the WAN (HS) external port
without going through the MPH device.
- integrated - in this mode, the router works so that it is integrated in the MPH
and routes DLCIs into the device."
::= { mdlCPrgEntry 6}
mdlCDhcpClientEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the feature of DHCP Client for the selected card."
::= { mdlCPrgEntry 7}
mdlCRdnExists OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether any port of the programmed card is
configured to be part of a Redundancy/APS pair.
If at least one port of the programmed card is configured to be
part of a Redundancy/APS pair, the value will be 'yes'.
Otherwise, it will be 'no'."
::= { mdlCPrgEntry 8}
mdlCInterfaces OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Octet string which indicates 'present' interfaces in card.
Each '0' bit stands for non-present interface.
Each '1' bit stands for present interface.
For ASMi54C card of LRS-102 and MP-4100 notPresent interfaces may be:
- SHDSL Line ID with no wire pairs assigned to it (does not exist in ifTable)
- PCS without SHDSL Line binded to it, (exist in ifTable, with
ifOperStatus= notPresent)
- External DS1 when its LIU is used by an Internal DS1 of the same card
- Internal DS1 when single bearer is not TDM.
In each octet, MS bit represents port 1
and LS bit represents port 8
MSB LSB
1 0 0 0 1 0 0 0 -- Example: Port # 1 and 5 are present.
Port 1 2 3 4 5 6 7 8
1st Octet (MSB octet) represents SDHSL Lines
2nd Octet represents PCS
3rd Octet represents External DS1
4th Octet represents Internal DS1
5th and 6th Octets are reserved for future Internal DS1.
For OP-108/106 cards of LRS-102 and MP-4100 notPresent interfaces may be:
- External DS1 when its 'associated' Int-DS1 port is connected to another card
- Internal DS1 when its 'associated' Ext-DS1 port is connected to another card
(Both may be 'present' when inter-connected).
1st Octet represents External DS1
2nd Octet represents Internal DS1
Bit representation, same as for ASMi-54C card.
"
::= { mdlCPrgEntry 9 }
--
-- Compressed information.
--
-- Specially for RadView management station
--
mdlCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprMdlGen 1 }
mdlCmprEntry OBJECT-TYPE
SYNTAX MdlCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlCmprTypIdx, mdlCmprCnfgIdx ,mdlCmprVersion,mdlCmprSltIdx }
::= {mdlCmprTable 1}
MdlCmprEntry ::=
SEQUENCE {
mdlCmprTypIdx Integer32,
mdlCmprCnfgIdx Integer32,
mdlCmprVersion Integer32,
mdlCmprSltIdx INTEGER,
mdlCmprObj OCTET STRING
}
mdlCmprTypIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Type of the Compressed being
referred."
::= { mdlCmprEntry 1}
mdlCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the configuration to which the
Compressed information is related."
::= { mdlCmprEntry 2}
mdlCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format
of the Compressed data"
::= { mdlCmprEntry 3}
mdlCmprSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number of the slot
position where the card is inserted.
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
are not valid."
::= { mdlCmprEntry 4}
mdlCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { mdlCmprEntry 5}
-- Compressed Alarm table at Card level
-- The only way of reading this table is by the command 'GET NEXT'
mdlAlarmsCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {cmprMdlGen 2}
mdlAlarmsCmprEntry OBJECT-TYPE
SYNTAX MdlAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {mdlAlarmsCmprVersion,
mdlAlarmsCmprAlarmSlot,mdlAlarmsCmprAlarmIdx}
::= {mdlAlarmsCmprTable 1}
MdlAlarmsCmprEntry ::=
SEQUENCE {
mdlAlarmsCmprVersion Integer32,
mdlAlarmsCmprAlarmSlot Integer32,
mdlAlarmsCmprAlarmIdx Integer32,
mdlAlarmsCmprObj OCTET STRING
}
mdlAlarmsCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format
of the Compressed data"
::= { mdlAlarmsCmprEntry 1}
mdlAlarmsCmprAlarmSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the desired slot position.
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
are not valid."
::= { mdlAlarmsCmprEntry 2}
mdlAlarmsCmprAlarmIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table
of the agent."
::= { mdlAlarmsCmprEntry 3}
mdlAlarmsCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { mdlAlarmsCmprEntry 4}
--
-- Wan port status general information
--
prtSInstTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSInstEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { statPrtGen 1 }
prtSInstEntry OBJECT-TYPE
SYNTAX PrtSInstEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtSInstSltIdx, prtSInstPrtIdx }
::= { prtSInstTable 1}
PrtSInstEntry ::= SEQUENCE {
prtSInstSltIdx INTEGER,
prtSInstPrtIdx Integer32,
prtSInstPrtType INTEGER,
prtSInstIfIndex Integer32,
prtSActiveStatus INTEGER,
prtSAlrStatus INTEGER,
prtSMaskedAlrStat INTEGER,
prtSClearAlrCmd INTEGER,
prtSTestMask Integer32,
-- prtSTstStatus INTEGER,
prtSTstCmd INTEGER,
prtSTstDuration Integer32,
prtSBertClrCmd INTEGER,
prtSBertTstRslt Integer32,
prtSInterfaceType DisplayString,
prtSParamStatus OCTET STRING,
prtSTestMaskXp OCTET STRING,
prtSRdnStatus INTEGER
}
prtSInstSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify the
slot where the card is inserted.
In the ?004 Unit the entries io6(10)..io(16) are not valid.
For the Vmux2100 Main Board clA (3) is used."
::= { prtSInstEntry 1}
prtSInstPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number to identify a port
in a specific card.
The valid ports depend on the installed card:
the valid external ports (interfaces) are (1..mdlCNoOfExternPrt) if any,
and the valid internal ports are (101..100+mdlCNoOfInternPrt) if any.
Generally, for MP-2100/2200: exPrt1 (1) .. exPrt16 (16),inPrt1(101)
.. inPrt48 (148)
For the Vmux-2100 device:
This index will have values of 1...4 for the physical ports & values
of ifIndex for the bundles.
For other products, see product's spec."
::= { prtSInstEntry 2}
prtSInstPrtType OBJECT-TYPE
SYNTAX INTEGER
{
external (2),
internal (3),
highSpeedV35 (4),
highSpeedV24 (5),
highSpeedV36 (6),
highSpeedX21 (7),
highSpeedG703 (8),
highSpeedDDS (9),
lowSpeed (10),
voice (11),
cl (12),
isdns (13),
isdnu (14),
ethernet (15),
voiceS0 (16),
voiceU (17),
voiceQsigS (18),
voiceQsigU (19)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the type of the designated port.
In MX 3000 only external & internal options are used.
All the other options are only for MX 30/300 which need special handling.
In order to support interface types in MX 3000, return an ascii string for
prtSInterfaceType in this table or support the general RAD value of
physicalConnector.
External port - is a port with a physical connector.
Internal port - might be of two types:
a) A composite port which collects a few external ports
data into a common bandwidth (usually routed through
DS1 link)
b) A port which gets only part of the external ports
(usually a few DS0's)
The following types are used when all ports are external/
internal and the connector/interface type is necessary
(for example, stand-alone units):
High Speed port types
Low Speed port types
Voice port types, CL port types.
ISDN Voice in MX 30/300 Phase 4: voiceS0 (16), voiceU (17) should be used.
ISDN Voice in MX 30/300 Phase 5: voiceQsigS(18), voiceQsigU (19) should be used."
::= { prtSInstEntry 3}
prtSInstIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the unique interface number
assigned to the port. The specific interface of this
attribute is the same as the interface identified by the
value of ifindex in MIB-II.If there is no interface for
the specific prtIdx the value will be '7fffffff'h."
::= { prtSInstEntry 4}
prtSActiveStatus OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
notUsed (2),
offLine (3),
onLine (4),
offLineRedundancy (5),
onLineRedundancy (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the activity status of the port.
unknown(1) indicates that the information is not supported.
notUsed(2) indicates that the ch is not connected according
to the active config.
offLine(3) indicates that the ch is down (not working)
because of any problem.
onLine(4) indicates that the ch is up (working)
offLineRedundancy(5) indicates that the ch is down, because
it is redundant port.
onLineRedundancy(6) indicates that the ch is up, and it is
the active link"
::= { prtSInstEntry 5}
prtSAlrStatus OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the port(ch) agent level.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= { prtSInstEntry 6}
prtSMaskedAlrStat OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the alarm state in the port(ch) agent level,
including Masked alarms.
This attribute will be set to:
critical(7) - when there is at least one active (state ON)
critical alarm,
otherwise it will be set to
major(5) - when there is at least one active (state ON)
major alarm,
otherwise it will be set to
minor(4) - if there is at least one active (state ON) minor
alarm,
otherwise it will be set to
warning(6) - if there is at least one active (state ON)
warning alarm,
otherwise it will be set to
event(3) - if there was at least one alarm event (including
state on,off events) since the last clear operation."
::= {prtSInstEntry 7}
prtSClearAlrCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to on(3) enforces a clear operation
of the alarm status events in the given port. The clear
operation will not be applied for masked/inverted alarms."
::= { prtSInstEntry 8}
prtSTestMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is a mask which indicates which tests from the
'prtSTstCmd' list are allowed for the requested port.
If a specific test is allowed, its respective bit
will be SET in the mask :
TEST BIT
----------- ---
local-loop 1
remote-loop 2
loc-and-rem-main-loops 3
remote-analog-loop 4
remote-digital-loop 5
rem-loop-on-ext-unit 6
bert 7
tone-injection 8
dlci local-loop 9
all dlci local-loop 10
dlci remote-loop 11
all dlci remote-loop 12
bert-and-rem-loop-on-rem-unit 13
rem-loop-on-rem-unit 14
block 15
backward-tone-inject 16
llb 17
rlb 18
ft1Enable 21
lbbd 22 --for 2B+D
lb1 23 --for B1
lb2 24 --for B2
llb-on-rem-unit 25
bert-on-rem-unit 26
bert-on-rem-and-llb-on-rem-unit 27
local-and-bert-on-rem-unit 28
local-loop-on-rem-unit 29
localBert 30 --towards IO ports
test-per-TS 31
e.g : If the return value is 3 -> 0000000000000011 ->
Bits 1 & 2 are set -> the allowed tests are :
local-loop
remote-loop
"
::= { prtSInstEntry 9}
-- prtSTstStatus OBJECT-TYPE
-- SYNTAX INTEGER
-- {
-- off(2),
-- on (3)
-- }
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This attribute will be set to on(3) when there is at least
-- one test in progress in the port, otherwise the value
-- will be off(2)."
-- ::= { prtSInstEntry 10}
--
prtSTstCmd OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
localLoop (2),
remoteLoop (3),
locAndRemMainLoops (4),
remoteAnalogLoop (5),
remoteDigitalLoop (6),
remLoopOnExtUnit (7),
bert (8),
toneInjection (9),
dlciLocalLoop (10),
allDlciLocalLoop (11),
dlciRemoteLoop (12),
allDlciRemoteLoop (13),
extInitLocalLoop (14),
bertAndRemLoopOnRemUnit (15),
remLoopOnRemUnit (16),
block (17),
backwardToneInject (18),
llb (19),
rlb (20),
ft1Enable (21),
lbbd (22), --for 2B+D
lb1 (23), --for B1
lb2 (24), --for B2
llbOnRemUnit (25),
bertOnRemUnit (26),
bertOnRemAndLlbOnRemUnit (27),
localAndBertOnRemUnit(28),
localLoopOnRemUnit (29),
localBert (30),
testPerTS (31),
csuLoopAndBert (32),
dsuLoopAndBert (33),
remoteOcuLoopAndBert (34),
remoteCsuLoopAndBert (35),
remoteDsuLoopAndBert (36)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to any of the above values will
initiate a test on the specific port if the operation is
legal. If the operation is not legal, the mux will ignore
the operation.
testPerTS(31) - when this test is selected, the selection of tests
for each TS is done via the prtExPh1MlTsTest object.
If a test time out is needed, the test will be set with a
default timeout of 2 minutes until the user will set the
parameter 'prtSTstDuration' to the required time out.
If no time out is needed , the test will be set with infinite
timeout until the user will set the parameter
'prtSTstDuration' to the required time out."
::= { prtSInstEntry 10}
prtSTstDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the maximum duration of executing
a test on the specific port. This entry applies to all the
test operations. The resolution will be a minute, and the
maximum duration is limited to 30 minutes.
For Vmux devices, the values are in seconds.
A zero value specifies no time limitation.
When the test isn't active, the agent initiates this object to
2 when the duration is needed and to 0 if its not required.
The user should set this parameter after setting the
'prtSTstCmd' parameter."
::= { prtSInstEntry 11}
prtSBertClrCmd OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute initiates bert count clear operation.
It is valid only when bert test is active on the specific
port."
::= { prtSInstEntry 12}
prtSBertTstRslt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the number of Bit Error Rate
indicated during the BERT operation.
It is valid only when bert test is active on the specific
port."
::= { prtSInstEntry 13}
prtSInterfaceType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique HW interface type of the
selected port."
::= { prtSInstEntry 14}
prtSParamStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates Status of parameters specific to the
selected port.
- For a port that has no special status or is supported
by prtSExHsfStatTable - 1 Octet: 00hex
- For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet :
Bit 7 (MSB)..Bit 2 = 0 (NA)
Bit 1: Tx Signaling '1'=On ; '0'=Off
Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off
- For VC-2/R2(FXS) external ports - 1 Octet :
Bit - 7 6 5 4 3 2 1 0
|_| |_________|
Call Call State
Direction
Bit 7 (MSB) and Bit 6 : Call Direction
00 - Incoming
01 - Outgoing
Bit 5..Bit 0: Call State
000000 - Idle
000001 - Seized
000010 - Both-Way Conflict
000011 - Seizure Ack
000100 - Answered
000101 - Clear Backward
000110 - Clear Forward
000111 - Blocked
001000 - Fault
001001 - Fault 3
001010 - Fault 4
001011 - Fault 5
001100 - Fault 6
001101 - Fault 7
- For ML-20 external port - 3 Octets :
- 1 MS Octet will represent the Real Rate used:
Bit - 7 6 5 4 3 2 1 0
|___| |_______|
spare Rate
Valid values: 0..31, meaning 0..31x64Kbps
Invalid values: 32..255.
- 2 LS Octets will represent the Status of 7 Control
Signals:
Signal - --- CTS DSR DCD RJ TM DTR RTS
Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Octet - 2 3 (LS)
'---' will always have the value 00
Rest of the Signals (2 bits each) can have the following
values:
00=NA ; 01=unused ; 10=Off ; 11=On
- For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet
Bit - 7 6 5 4 3 2 1 0
|___________|
spare Mode of Operation
Mode of Operation: '1'=Central ; '0'=Remote
- For ACM external port - 1 Octet
Bit - 7 6 5 4 3 2 1 0
|_________|
spare Alarm State
Alarm State: according to bits 1,0:
00=NA ; 01=unused ; 10=Off ; 11=On
- For HS-U/1 external port - 1 Octet
Bit 7 6 5 4 3 2 1 0 LSB
|________| |__| |__|
spare modem sync
modem: 00 = other sync: 00 = not sync
01 = unknown 01 = sync
10 = ASMi-31/2 10 = reserved
11 = reserved 11 = reserved
- For MTML-2/4 external ports, ML-8 externalports, ML-IP (MTML-IP)
internal ports and MTML-E2 internal ports - 1 Octet :
Bit 7 6 5 4 3 2 1 0 LSB
|
BERT State
BERT State (Bit 0):
0 = OFF (BERT is not running on this port or any of its TSs/Bits)
1 = ON (BERT is running on this port OR on one of its TSs/Bits)
- For ML-20N external ports - 4 Octets
- 1 MS Octet will represent the Actual Link Rate:
Bit - 7 6 5 4 3 2 1 0
|_| |_________|
spare Rate
Valid values: 0..34, meaning:
0..32 = (0..32)x64Kbps
33 = Invalid Rate
34 = not applicable (when Rate is not Auto)
35 = 0 Kbps
Invalid values: 36..255.
- 2 middle Octets will represent the Status of 4 Control
Signals:
- LS Octet - Bits 3-0: RTS/C (Command, for X.21 interface)
Bits 7-4: DCD/I (Indication for X.21 interface)
- MS Octet - Bits 3-0: DTR
Bits 7-4: DSR
Each 4 Bits are divided as follows:
- 2 MS bits: DCE
- 2 LS bits: DTE
For each 2 bits (DCE/DTE):
00=NA ; 01=unused ; 10=Off ; 11=On.
- LS Octet: (as for MTML-2):
Bit 7 6 5 4 3 2 1 0 LSB
|
BERT State
BERT State (Bit 0):
0 = OFF (BERT is not running on this port or any of its TSs/Bits)
1 = ON (BERT is running on this port OR on one of its TSs/Bits)
- For MP-2100/2200 MSL-4/E1, MSL-8/E1 External ports - 3 Octets
- MS octet: far-end modem channel interface
- Middle octet: Material (plastic/metal), far-end modem type,
synchronization with far-end modem
- LS octet: BERT state (at port/TS/Bit level)
- MS octet: 0000 0000 = no interface
0000 0001 = db15 (X21)
0000 0010 = IR-IP
0000 0011 = IR-ETH-Q
0000 0100 = V35
0000 0101 = ETH-RJ45
0000 0110 = G703
0000 0111 = db25 (RS530)
0000 1000 = ETH-BNC
0000 1001 = E1(Balanced)
0000 1010 = E1(Unbalanced)
0000 1011 = IR-ETH-QN
Rest of the combinations: reserved
- Middle octet:
Bit 7 6 5 4 3 2 1 0 LSB
| |___________| |__|
Box material modem sync
Box material modem: 00000 = other sync: 00 = not sync
(for ASMi-52 SA) 00001 = unknown 01 = sync
0=metal 00010 = reserved 10 = reserved
1=plastic 00011 = reserved 11 = reserved
00100 = reserved
00101 = reserved
00110 = ASMi-52 SA/2W/Slave
00111 = ASMi-52 SA/2W/Master
01000 = ASMi-52/CQ card of LRS-24
01001 = ASMi-52/CD card of LRS-24
01010 = D16GSDSL card of DXC-3000
01011 = LRS-52
01100 = FCD-IP
01101 = FCD-IPM
01110 = D8SL card of DXC-30
01111 = ASMi-52A
10000 = MP card (SHDSL)
10001 = ASMi-52L
Rest = reserved
- LS Octet: (as for MTML-2):
Bit 7 6 5 4 3 2 1 0 LSB
|
BERT State
BERT State (Bit 0):
0 = OFF (BERT is not running on this port or any of its TSs)
1 = ON (BERT is running on this port OR on one of its TSs)
- For MP-4100 MSL card Links - 4 Octets
- MS octet: far-end modem DTE2 interface (same as for MP-2100 MSL cards)
- after MS octet: far-end modem DTE1 interface (same as for MP-2100 MSL cards)
- before LS octet: Material (plastic/metal), far-end modem type,
synchronization with far-end modem (same as for MP-2100 MSL cards)
- LS octet: BERT state (at port/TS/Bit level)- same as for MP-2100 MSL cards
- For MP-4100, LRS-102 OP-108/106 , OP-34/25 Links - 3 Octets
- MS octet: Far-End PS type and state
- Middle octet: synchronization with Far-End device
- LS octet: BERT state (at port/TS level) - same as for MP-2100 MSL cards
- MS octet:
Bit 7 6 5 4 3 2 1 0 LSB
|__| |__| |__| |__|
PS-A PS-A PS-B PS-B
PS Type PS State PS Type PS State
00=None 00=None
01=AC-DC 01=OK
10=DC 10=Fail
11=AC
- Middle octet:
Bit 7 6 5 4 3 2 1 0 LSB
|__|
sync:
00 = not sync
01 = sync
10 = reserved
11 = reserved
Rest = reserved
"
::= { prtSInstEntry 15}
prtSTestMaskXp OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is an Expanded test mask of the prtSTestMask object.
The prtSTestMask object reached its maximum, being an Integer with 32 bits.
This object indicates which tests from the 'prtSTstCmdXP' list are
allowed for the selected port.
If a specific test is allowed, its respective bit will be SET
in the mask :
TEST BIT
----------- ---
local-loop 1
remote-loop 2
loc-and-rem-main-loops 3
remote-analog-loop 4
remote-digital-loop 5
rem-loop-on-ext-unit 6
bert 7
tone-injection 8
dlci local-loop 9
all dlci local-loop 10
dlci remote-loop 11
all dlci remote-loop 12
bert-and-rem-loop-on-rem-unit 13
rem-loop-on-rem-unit 14
block 15
backward-tone-inject 16
llb 17
rlb 18
ft1Enable 21
lbbd 22 --for 2B+D
lb1 23 --for B1
lb2 24 --for B2
llb-on-rem-unit 25
bert-on-rem-unit 26
bert-on-rem-and-llb-on-rem-unit 27
local-and-bert-on-rem-unit 28
local-loop-on-rem-unit 29
localBert 30 --towards IO ports
test-per-TS 31
csuLoopAndBert 32
dsuLoopAndBert 33
remoteOcuLoopAndBert 34
remoteCsuLoopAndBert 35
remoteDsuLoopAndBert 36
e.g : If the return value is 00000003 hex ->
Bits 1 & 2 are set -> the allowed tests are :
local-loop
remote-loop "
::= { prtSInstEntry 16}
prtSRdnStatus OBJECT-TYPE
SYNTAX INTEGER {
noRdn (1),
offline(2),
online (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Redundancy Status of this port.
noRdn - this port is not part of a Redundancy pair/group.
offline - this port is offline from Redundancy point of view.
online - this port is online from Redundancy point of view."
::= { prtSInstEntry 17}
prtSAlrTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The list of port agent alarms."
::= { statPrtGen 2 }
prtSAlrEntry OBJECT-TYPE
SYNTAX PrtSAlrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtSAlrSltIdx, prtSAlrPrtIdx, prtSAlrIdx}
::= { prtSAlrTable 1}
PrtSAlrEntry ::=
SEQUENCE {
prtSAlrSltIdx INTEGER,
prtSAlrPrtIdx Integer32,
prtSAlrIdx Integer32,
prtSAlrCodeDescription DisplayString,
prtSAlrCode Integer32,
prtSAlrSeverity INTEGER,
prtSAlrState INTEGER,
prtSAlrCounter Integer32,
prtSAlrMask INTEGER,
prtSAlrInvert INTEGER,
prtSAlrCardType INTEGER
}
prtSAlrIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table.
Users should use the get next function to read this table because
the indexes are not consecutive"
::= { prtSAlrEntry 1}
prtSAlrSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the slot
where the card is inserted.
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16)
are not valid.
For the Vmux2100 Main Board clA (3) is used."
::= { prtSAlrEntry 2}
prtSAlrPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the port
the alarm applies to.
All the values are valid. No alarms exist for a port
which does not exist.
Valid valuesfor MP-2100/2200: exPrt1 (1) .. exPrt16 (16) ,
inPrt1 (101) .. inPrt48 (148),
IP Bundles.
For other products, see product's spec."
::= { prtSAlrEntry 3}
prtSAlrCodeDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is a full text description of the alarm.
The alarm description includes the following information:
alarm code, alarm text, alarm severity, Masked or Inverted
flag and counter."
::= { prtSAlrEntry 4}
prtSAlrCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A code identifying the alarm of an entry in the alarm status
table at port level."
::= { prtSAlrEntry 5 }
prtSAlrSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity of the alarm."
::= { prtSAlrEntry 6 }
prtSAlrState OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of the alarm."
::= { prtSAlrEntry 7 }
prtSAlrCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A counter - how many times the alarm occured since last
clear operation.
ON and OFF Alarm will be counted separately."
::= { prtSAlrEntry 8 }
prtSAlrMask OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm mask : on/off."
::= { prtSAlrEntry 9 }
prtSAlrInvert OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm invert : on/off."
::= { prtSAlrEntry 10 }
prtSAlrCardType OBJECT-TYPE
SYNTAX INTEGER
{
--
-- General types
--
unknown (1),
empty (2),
--
-- Power Supply Modules
--
ps (17),
--
-- Cl Modules
--
cl1 (20),
cl1Clk (26), --CL1 with Station Clock (for LRS102)
-- VF cards of Megaplex
vf24T1 (62),
vf30E1 (63),
vf48T1 (64),
vf60E1 (65),
--
-- TDM Cards
--
vc8EandM (74),
vc8Fxo (75),
vc8Fxs (76),
vc16EandM (77),
vc16Fxo (78),
vc16Fxs (79),
ml8T1 (134),
ml8E1 (135),
hsr (156),
ls12 (159),
ls6n (180),
hsEthSwitch (224),
hsu12 (240),
hsu6 (241),
vc4Fxs (255),
vc4EandM (256),
vc4Fxo (257),
msl4E1W2 (261),
msl8E1W2 (263),
msl4E1W2Eth (264),
msl8E1W2Eth (265),
asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH)
asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH)
asmi54c (268), -- & LRS-102 (ETH only)
hs6N (271),
hs12N (272),
-- MP-4100 (and LRS-102) cards
clx1 (301),
clx1GbE (302),
clx1S155 (303),
clx1S155GbE (304),
ml8T1Eth (305),
ml8E1Eth (306),
op106cEth (307), --no external T1
op108cEth (308), --no external E1
op106cEthT1 (309), --with external T1 (used also by LRS-102)
op108cEthE1 (310), --with external E1 (used also by LRS-102)
op108cEthE1Unbal(311), --used only by LRS-102
mpw1 (312),
-- VFS cards of Megaplex
vfs24T1 (321),
vfs30E1 (322),
vfs48T1 (323), --2T1
vfs60E1 (324) --2E1
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the type of card installed
in the specific slot position. The enumeration is according
to mdlSInstCardType."
::= { prtSAlrEntry 11 }
--
-- Statistics of Ports
--
--statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3}
--prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1}
--prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2}
--prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3}
--prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4}
--prtFrStatis - Port Statistics for (FR) Frame Relay protocol
prtFrStatisTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtFrStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is applicable only for an active port running an
FR protocol ."
::= { prtFrStatis 1}
prtFrStatisEntry OBJECT-TYPE
SYNTAX PrtFrStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtFrStatisSltIdx, prtFrStatisPrtIdx, prtFrStatisInvIdx}
::= { prtFrStatisTable 1}
PrtFrStatisEntry ::=
SEQUENCE {
prtFrStatisSltIdx INTEGER,
prtFrStatisPrtIdx INTEGER,
prtFrStatisInvIdx INTEGER,
prtFrTimeElapsed Integer32,
prtFrRxTotalFrames Counter32,
prtFrTxTotalFrames Counter32,
prtFrRxTotalBytes Counter32,
prtFrTxTotalBytes Counter32,
prtFrRxMngFrames Counter32,
prtFrTxMngFrames Counter32,
prtFrRxDeFrames Counter32,
prtFrTxDeFrames Counter32,
prtFrRxDcrdCongDeFr Counter32,
prtFrTxDcrdCongDeFr Counter32,
prtFrRxDcrdCongAllFr Counter32,
prtFrTxDcrdCongAllFr Counter32,
prtFrRxFecn Counter32,
prtFrTxFecn Counter32,
prtFrRxBecn Counter32,
prtFrTxBecn Counter32,
prtFrRxBeViol Counter32,
prtFrTxBeViol Counter32,
prtFrRxBcViol Counter32,
prtFrTxBcViol Counter32
}
prtFrStatisSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
For stand-alone units this index will be notApplicable (255)."
::= { prtFrStatisEntry 1}
prtFrStatisPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtFrStatisEntry 2}
prtFrStatisInvIdx OBJECT-TYPE
SYNTAX INTEGER
{
currentInv (1),
last (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Interval of 15 min. for which the following statistics
counters are applicable."
::= { prtFrStatisEntry 3}
prtFrTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the
beginning of the current error-measurement interval.
This object is applicable mainly for the current interval.
For other interval:
- if data is available: value will be 899.
- if data is not available: value will be 0."
::= { prtFrStatisEntry 4 }
prtFrRxTotalFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames received by this port during the
selected interval."
::= { prtFrStatisEntry 5 }
prtFrTxTotalFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames sent by this port during the
selected interval."
::= { prtFrStatisEntry 6 }
prtFrRxTotalBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes received by this port during the
selected interval."
::= { prtFrStatisEntry 7 }
prtFrTxTotalBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes sent by this port during the
selected interval."
::= { prtFrStatisEntry 8 }
prtFrRxMngFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management number of frames received by this port
during the selected interval."
::= { prtFrStatisEntry 9 }
prtFrTxMngFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The management number of frames sent by this port during the
selected interval."
::= { prtFrStatisEntry 10 }
prtFrRxDeFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames received by this port during the
selected interval."
::= { prtFrStatisEntry 11 }
prtFrTxDeFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames sent by this port during the
selected interval."
::= { prtFrStatisEntry 12 }
prtFrRxDcrdCongDeFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames discarded due to congestion,
received by this port during the selected interval."
::= { prtFrStatisEntry 13 }
prtFrTxDcrdCongDeFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames discarded due to congestion,
sent by this port during the selected interval."
::= { prtFrStatisEntry 14 }
prtFrRxDcrdCongAllFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All the frames discarded due to congestion,
received by this port during the selected interval."
::= { prtFrStatisEntry 15 }
prtFrTxDcrdCongAllFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All the frames discarded due to congestion,
sent by this port during the selected interval."
::= { prtFrStatisEntry 16 }
prtFrRxFecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames received by this port during the
selected interval, indicating forward congestion."
::= { prtFrStatisEntry 17 }
prtFrTxFecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames sent by this port during the
selected interval, indicating forward congestion."
::= { prtFrStatisEntry 18 }
prtFrRxBecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames received by this port during the
selected interval, indicating backward congestion."
::= { prtFrStatisEntry 19 }
prtFrTxBecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames sent by this port during the
selected interval, indicating backward congestion."
::= { prtFrStatisEntry 20 }
prtFrRxBeViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames received by this port during the
selected interval, exceeding the Burst Excess value."
::= { prtFrStatisEntry 21 }
prtFrTxBeViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames sent by this port during the
selected interval, exceeding the Burst Excess value."
::= { prtFrStatisEntry 22 }
prtFrRxBcViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames received by this port during the
selected interval, exceeding the Burst Committed value."
::= { prtFrStatisEntry 23 }
prtFrTxBcViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames sent by this port during the
selected interval, exceeding the Burst Committed value."
::= { prtFrStatisEntry 24 }
--prtCrStatis - Port Statistics for (CR) Cell Relay protocol
prtCrStatisTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtCrStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is applicable only for an active port running a
CR protocol ."
::= { prtCrStatis 1}
prtCrStatisEntry OBJECT-TYPE
SYNTAX PrtCrStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtCrStatisSltIdx, prtCrStatisPrtIdx, prtCrStatisInvIdx}
::= { prtCrStatisTable 1}
PrtCrStatisEntry ::=
SEQUENCE {
prtCrStatisSltIdx INTEGER,
prtCrStatisPrtIdx INTEGER,
prtCrStatisInvIdx INTEGER,
prtCrTimeElapsed Integer32,
prtCrRxTotalCells Counter32,
prtCrTxTotalCells Counter32,
prtCrRxDataCells Counter32,
prtCrTxDataCells Counter32
}
prtCrStatisSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
For stand-alone units this index will be notApplicable (255)."
::= { prtCrStatisEntry 1}
prtCrStatisPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtCrStatisEntry 2}
prtCrStatisInvIdx OBJECT-TYPE
SYNTAX INTEGER
{
currentInv (1),
last (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Interval of 15 min. for which the following statistics
counters are applicable."
::= { prtCrStatisEntry 3}
prtCrTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the
beginning of the current error-measurement interval.
This object is applicable mainly for the current interval.
For other interval:
- if data is available: value will be 899.
- if data is not available: value will be 0."
::= { prtCrStatisEntry 4 }
prtCrRxTotalCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells received by this port during the
selected interval."
::= { prtCrStatisEntry 5 }
prtCrTxTotalCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells sent by this port during the
selected interval."
::= { prtCrStatisEntry 6 }
prtCrRxDataCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Data Cells received by this port during the
selected interval."
::= { prtCrStatisEntry 7 }
prtCrTxDataCells OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Data Cells sent by this port during the
selected interval."
::= { prtCrStatisEntry 8 }
--prtDlciStatis - Port DLCI Statistics for FR, FR+ and CR protocol
prtDlciStatisTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDlciStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is applicable only for an active port running an
FR, FR+ or CR protocol, with valid DLCIs ."
::= { prtDlciStatis 1}
prtDlciStatisEntry OBJECT-TYPE
SYNTAX PrtDlciStatisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtDlciSltIdx, prtDlciPrtIdx, prtDlciIdx}
::= { prtDlciStatisTable 1}
PrtDlciStatisEntry ::=
SEQUENCE {
prtDlciSltIdx INTEGER,
prtDlciPrtIdx INTEGER,
prtDlciIdx Integer32,
prtDlciRxDeFrames Counter32,
prtDlciTxDeFrames Counter32,
prtDlciRxDcrdCongDeFr Counter32,
prtDlciTxDcrdCongDeFr Counter32,
prtDlciRxDcrdCongAllFr Counter32,
prtDlciTxDcrdCongAllFr Counter32,
prtDlciTxFecn Counter32,
prtDlciTxBecn Counter32,
prtDlciRxBeViol Counter32,
prtDlciTxBeViol Counter32,
prtDlciRxBcViol Counter32,
prtDlciTxBcViol Counter32
}
prtDlciSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
For stand-alone units this index will be notApplicable (255)."
::= { prtDlciStatisEntry 1}
prtDlciPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtDlciStatisEntry 2}
prtDlciIdx OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique DLCI index for each valid
DLCI (16..991). "
::= { prtDlciStatisEntry 3}
prtDlciRxDeFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames received by this DLCI."
::= { prtDlciStatisEntry 4 }
prtDlciTxDeFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames sent by this DLCI."
::= { prtDlciStatisEntry 5 }
prtDlciRxDcrdCongDeFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames discarded due to congestion,
received by this DLCI."
::= { prtDlciStatisEntry 6 }
prtDlciTxDcrdCongDeFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of De frames discarded due to congestion,
sent by this DLCI."
::= { prtDlciStatisEntry 7 }
prtDlciRxDcrdCongAllFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All the frames discarded due to congestion,
received by this DLCI."
::= { prtDlciStatisEntry 8 }
prtDlciTxDcrdCongAllFr OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"All the frames discarded due to congestion,
sent by this DLCI."
::= { prtDlciStatisEntry 9 }
prtDlciTxFecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames sent by this DLCI, indicating forward
congestion."
::= { prtDlciStatisEntry 10 }
prtDlciTxBecn OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames sent by this DLCI, indicating backward
congestion."
::= { prtDlciStatisEntry 11 }
prtDlciRxBeViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames received by this DLCI, exceeding the
Burst Excess value."
::= { prtDlciStatisEntry 12 }
prtDlciTxBeViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames sent by this DLCI, exceeding the Burst
Excess value."
::= { prtDlciStatisEntry 13 }
prtDlciRxBcViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames received by this DLCI, exceeding the
Burst Committed value."
::= { prtDlciStatisEntry 14 }
prtDlciTxBcViol OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of data frames sent by this DLCI, exceeding the Burst
Committed value."
::= { prtDlciStatisEntry 15 }
--prtT1 Last FDL Message Table - Statistics
prtT1FdlMsgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtT1FdlMsgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is applicable for a T1 interface with 'esf'
LineType ."
::= { prtT1Statis 1}
prtT1FdlMsgEntry OBJECT-TYPE
SYNTAX PrtT1FdlMsgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtT1FdlMsgSltIdx, prtT1FdlMsgPrtIdx, prtT1FdlMsgFdlTxRx}
::= { prtT1FdlMsgTable 1}
PrtT1FdlMsgEntry ::=
SEQUENCE {
prtT1FdlMsgSltIdx INTEGER,
prtT1FdlMsgPrtIdx INTEGER,
prtT1FdlMsgFdlTxRx INTEGER,
prtT1FdlMsg OCTET STRING
}
prtT1FdlMsgSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= { prtT1FdlMsgEntry 1}
prtT1FdlMsgPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
MTML-1/T1 modules have just one external interface."
::= { prtT1FdlMsgEntry 2}
prtT1FdlMsgFdlTxRx OBJECT-TYPE
SYNTAX INTEGER
{
tx (1),
rx (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Fdl tx/rx reference of the Fdl message."
::= { prtT1FdlMsgEntry 3}
prtT1FdlMsg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FDL message."
::= { prtT1FdlMsgEntry 4}
--
-- Extension of the Time Slot Config Table of ML ports
--
-- Time Slot is split to 8 Bits
prtExTsSplitTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExTsSplitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry, except prtExTsBitTest that will be
written directly to the Active Configuration."
::= {cnfgPrtGen 1}
prtExTsSplitEntry OBJECT-TYPE
SYNTAX PrtExTsSplitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExTsCnfgIdx, prtExTsSltIdx, prtExTsPrtIdx,
prtExTsIdx, prtExTsBit}
::= { prtExTsSplitTable 1}
PrtExTsSplitEntry ::=
SEQUENCE {
prtExTsCnfgIdx Integer32,
prtExTsSltIdx INTEGER,
prtExTsPrtIdx Integer32,
prtExTsIdx Integer32,
prtExTsBit Integer32,
prtExTsIConSlot INTEGER,
prtExTsIConPrt Integer32,
prtExTsBitTest INTEGER,
prtExTsTxSignaling OCTET STRING,
prtExTsRxSignaling OCTET STRING,
prtExTsTxIoSignaling OCTET STRING,
prtExTsRxIoSignaling OCTET STRING
}
prtExTsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExTsSplitEntry 1}
prtExTsSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
notApplicable - for stand-alone units."
::= { prtExTsSplitEntry 2}
prtExTsPrtIdx OBJECT-TYPE
SYNTAX Integer32
-- For MP:
-- {
-- exPrt1 (1),
-- inPrt1 (101)
-- }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
Most ML cards have only one external interface.
inPrt1 - for MTML-H/E1 cards.
For other products' index see their specification."
::= { prtExTsSplitEntry 3}
prtExTsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are:
1..24 for T1 Card and
1..31 for E1 interface.
In G732S-E1 lines, time slot 16 is not valid for data,
it is dedicated to multiframe synchronization bits
and voice signaling."
::= { prtExTsSplitEntry 4}
prtExTsBit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique Bit within the time slot.
The valid Bits are: 1..8.
255=NA."
::= { prtExTsSplitEntry 5}
prtExTsIConSlot OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the specified time slot is
connected/routed internally in the Agent and to which card
it is connected.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
notApplicable - for stand-alone units."
::= {prtExTsSplitEntry 6}
prtExTsIConPrt OBJECT-TYPE
SYNTAX Integer32
-- For MP:
-- {
-- exPrt1 (1) ,
-- exPrt2 (2) ,
-- exPrt3 (3) ,
-- exPrt4 (4) ,
-- exPrt5 (5) ,
-- exPrt6 (6) ,
-- exPrt7 (7) ,
-- exPrt8 (8) ,
-- exPrt9 (9) ,
-- exPrt10 (10) ,
-- exPrt11 (11) ,
-- exPrt12 (12) ,
--
-- noConnect (100),
--
-- inPrt1 (101) ,
-- inPrt2 (102) ,
-- inPrt3 (103) ,
-- inPrt4 (104) ,
-- inPrt5 (105) ,
-- inPrt6 (106) ,
-- inPrt7 (107) ,
-- inPrt8 (108) ,
-- inPrt9 (109) ,
-- inPrt10 (110) ,
-- inPrt11 (111) ,
-- inPrt12 (112)
-- }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the internally (In Mux)
connected/routed port.
For other products' index see their specification."
::= {prtExTsSplitEntry 7}
prtExTsBitTest OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
remoteBert (8),
localBert (30),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a test to be activated on the selected Bit.
It is applicable only when prtExPh1MlTsTest=split(254).
none - no test is applied for the selected Bit.
notApplicable - when prtExPh1MlTsTest is NOT split(254)."
::= { prtExTsSplitEntry 8}
prtExTsTxSignaling OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link - Tx Signaling per TS, for TSs having TS Type=Voice
(agnTsType=voice(2)).
It monitors what is sent to Link for the selected TS,
for A,B,C,D Signaling Bits.
Bit 1= LSB
Bit 8= MSB
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
::= { prtExTsSplitEntry 9}
prtExTsRxSignaling OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Link - Rx Signaling per TS, for TSs having TS Type=Voice
(agnTsType=voice(2)).
It monitors what is received from Link for the selected TS,
for A,B,C,D Signaling Bits.
Bit 1= LSB
Bit 8= MSB
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
::= { prtExTsSplitEntry 10}
prtExTsTxIoSignaling OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IO - Tx Signaling per TS, for TSs having TS Type=Voice
(agnTsType=voice(2)).
It monitors what is sent to IO port for the selected TS,
for A,B,C,D Signaling Bits.
Bit 1= LSB
Bit 8= MSB
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
::= { prtExTsSplitEntry 11}
prtExTsRxIoSignaling OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"IO - Rx Signaling per TS, for TSs having TS Type=Voice
(agnTsType=voice(2)).
It monitors what is received from IO port for the selected TS,
for A,B,C,D Signaling Bits.
Bit 1= LSB
Bit 8= MSB
Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA
Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA"
::= { prtExTsSplitEntry 12}
prtCnfgAgenda OBJECT IDENTIFIER ::= {cnfgPrtGen 2}
prtAgendaBehaviourTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtAgendaBehaviourEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtCnfgAgenda 1}
prtAgendaBehaviourEntry OBJECT-TYPE
SYNTAX PrtAgendaBehaviourEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtAgendaBehaviourCnfgIdx, prtAgendaBehaviourSltIdx,
prtAgendaBehaviourPrtIdx }
::= { prtAgendaBehaviourTable 1}
PrtAgendaBehaviourEntry ::=
SEQUENCE {
prtAgendaBehaviourCnfgIdx Integer32,
prtAgendaBehaviourSltIdx Integer32,
prtAgendaBehaviourPrtIdx Integer32,
prtAgendaBehaviourOnOff INTEGER
}
prtAgendaBehaviourCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtAgendaBehaviourEntry 1}
prtAgendaBehaviourSltIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter should be:
- slot number for MX3000
- 255 = N/A for MX300/30. "
::= { prtAgendaBehaviourEntry 2 }
prtAgendaBehaviourPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter should be:
- port number for MX300/30
- 100 = N/A for MX3000. "
::= { prtAgendaBehaviourEntry 3 }
prtAgendaBehaviourOnOff OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this command to on(3) enables the agenda function
at module (3000) or port (300/30) level."
DEFVAL { off }
::= { prtAgendaBehaviourEntry 4 }
prtCnfgAgendaTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtCnfgAgendaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows the user to schedule the time a session
is active per week basis."
::= { prtCnfgAgenda 2}
prtCnfgAgendaEntry OBJECT-TYPE
SYNTAX PrtCnfgAgendaEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtCnfgAgendaCnfgIdx, prtCnfgAgendaSltIdx,
prtCnfgAgendaPrtIdx, prtCnfgAgendaDayIdx, prtCnfgAgendaSesId }
::= { prtCnfgAgendaTable 1}
PrtCnfgAgendaEntry ::=
SEQUENCE {
prtCnfgAgendaCnfgIdx Integer32,
prtCnfgAgendaSltIdx Integer32,
prtCnfgAgendaPrtIdx Integer32,
prtCnfgAgendaDayIdx INTEGER,
prtCnfgAgendaSesId Integer32,
prtCnfgAgendaFrom Integer32,
prtCnfgAgendaTo Integer32
}
prtCnfgAgendaCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtCnfgAgendaEntry 1}
prtCnfgAgendaSltIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is equal to:
-slot number for MX3000
-255 = N/A for MX300/30"
::= { prtCnfgAgendaEntry 2}
prtCnfgAgendaPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is equal to:
- port number for MX300/30
- port number for MX3000. For example 1-4 in MHS-4 cards.
- 100 = N/A for MX3000 when not used."
::= { prtCnfgAgendaEntry 3}
prtCnfgAgendaDayIdx OBJECT-TYPE
SYNTAX INTEGER {
monday (1),
tuesday (2),
wednesday(3),
thursday (4),
friday (5),
saturday (6),
sunday (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute for which day of the week this row applies."
::= { prtCnfgAgendaEntry 4 }
prtCnfgAgendaSesId OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The user may define 4 different active intervals per day."
::= { prtCnfgAgendaEntry 5 }
prtCnfgAgendaFrom OBJECT-TYPE
SYNTAX Integer32 (0..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Start from time interval in seconds."
DEFVAL {86400}
::= { prtCnfgAgendaEntry 6 }
prtCnfgAgendaTo OBJECT-TYPE
SYNTAX Integer32 (0..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To time interval in seconds."
DEFVAL {86400}
::= { prtCnfgAgendaEntry 7 }
-- General Port Configuration parameters
prtGenCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtGenCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows the user to configure general
port parameters."
::= {cnfgPrtGen 3}
prtGenCnfgEntry OBJECT-TYPE
SYNTAX PrtGenCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtGenCnfgIdx, prtGenCnfgSltIdx, prtGenCnfgPrtIdx }
::= { prtGenCnfgTable 1}
PrtGenCnfgEntry ::=
SEQUENCE {
prtGenCnfgIdx Integer32,
prtGenCnfgSltIdx INTEGER,
prtGenCnfgPrtIdx Integer32,
prtGenCnfgLinkToSlot INTEGER,
prtGenCnfgLinkToPort Integer32,
prtGenCnfgPortId Integer32,
prtGenCnfgBusConnection INTEGER,
prtGenCnfgInbandMng INTEGER,
prtGenCnfgInbandMngRoutProt INTEGER,
prtGenCnfgProtectionMode INTEGER, --not used
prtGenCnfgConnect INTEGER,
prtGenCnfgSignalingType INTEGER
}
prtGenCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg.
The write operation is valid only to the TmpCnfg."
::= { prtGenCnfgEntry 1}
prtGenCnfgSltIdx OBJECT-TYPE
SYNTAX INTEGER
{ clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted."
::= { prtGenCnfgEntry 2}
prtGenCnfgPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique external or internal port number.
For MP:
exPrt1 (1) .. exPrt16 (16) ,
notApplicable(100),
inPrt1 (101) .. inPrt84 (184) "
::= { prtGenCnfgEntry 3}
prtGenCnfgLinkToSlot OBJECT-TYPE
SYNTAX INTEGER
{
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the slot of the ML card to which
the IO port is mapped."
::= { prtGenCnfgEntry 4}
prtGenCnfgLinkToPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port in the prtGenCnfgLinkToSlot of
the ML card to which the IO port is mapped.
For MP:
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109),
inPrt10 (110),
inPrt11 (111),
inPrt12 (112),
inPrt13 (113),
inPrt14 (114),
inPrt15 (115),
inPrt16 (116),
inPrt17 (117),
inPrt18 (118),
inPrt19 (119),
inPrt20 (120),
inPrt21 (121),
inPrt22 (122),
inPrt23 (123),
inPrt24 (124),
inPrt25 (125),
inPrt26 (126),
inPrt27 (127),
inPrt28 (128),
inPrt29 (129),
inPrt30 (130),
inPrt31 (131),
inPrt32 (132),
inPrt33 (133),
inPrt34 (134),
inPrt35 (135),
inPrt36 (136),
inPrt37 (137),
inPrt38 (138),
inPrt39 (139),
inPrt40 (140),
inPrt41 (141),
inPrt42 (142),
inPrt43 (143),
inPrt44 (144),
inPrt45 (145),
inPrt46 (146),
inPrt47 (147),
inPrt48 (148),
inPrt49 (149),
inPrt50 (150),
inPrt51 (151),
inPrt52 (152),
inPrt53 (153),
inPrt54 (154),
inPrt55 (155),
inPrt56 (156),
inPrt57 (157),
inPrt58 (158),
inPrt59 (159),
inPrt60 (160),
inPrt61 (161),
inPrt62 (162),
inPrt63 (163),
inPrt64 (164),
inPrt65 (165),
inPrt66 (166),
inPrt67 (167),
inPrt68 (168),
inPrt69 (169),
inPrt70 (170),
inPrt71 (171),
inPrt72 (172),
inPrt73 (173),
inPrt74 (174),
inPrt75 (175),
inPrt76 (176),
inPrt77 (177),
inPrt78 (178),
inPrt79 (179),
inPrt80 (180),
inPrt81 (181),
inPrt82 (182),
inPrt83 (183),
inPrt84 (184),
notApplicable (255) "
::= { prtGenCnfgEntry 5}
prtGenCnfgPortId OBJECT-TYPE
SYNTAX Integer32 (0..16777215)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IO Port Id for V5.1 use.
This object is applicable only for part of the PSTN and ISDN IO ports.
Generally, 0 is a valid value.
Nevertheless, for ports that do not support this object, the value
will be: notApplicable= 0"
::= { prtGenCnfgEntry 6}
prtGenCnfgBusConnection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
partial (2),
full (3),
partialCD (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the support of the card regarding Bus Connection.
Same value for all ports of the card.
partial = 2 Buses (AB)
full = 4 Buses (ABCD)
partial CD = 2 Buses CD
Actually the support depends on the card's HW. But, since CL has to assign
data on Buses even when the card is not installed, this object has to be
configured.
If the actual card installed will not match the value configured, an Alarm
will be issued."
::= { prtGenCnfgEntry 7}
prtGenCnfgInbandMng OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether Inband Management is used over the
link."
::= {prtGenCnfgEntry 8}
prtGenCnfgInbandMngRoutProt OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
rip2 (2),
proprietaryRip (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Inband Mng Routing Protocol of
the port."
::= {prtGenCnfgEntry 9}
prtGenCnfgProtectionMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
secondary (2),
primary (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Protection Mode of the port.
notApplicable- when Bus Protection Point=No.
For VC-4/Omni card this object is supported RO."
::= {prtGenCnfgEntry 10}
prtGenCnfgConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port should be considered in
any of the mux algorithms."
::= {prtGenCnfgEntry 11}
prtGenCnfgSignalingType OBJECT-TYPE
SYNTAX INTEGER
{
legacy (3),
abcd (4),
none (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object selects the Type of Signaling used by the port."
::= {prtGenCnfgEntry 12}
--
-- Compressed information.
--
-- Specially for RadView management station
--
prtCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprPrtGen 1 }
prtCmprEntry OBJECT-TYPE
SYNTAX PrtCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtCmprTypIdx, prtCmprCnfgIdx,prtCmprVersion,prtCmprSltIdx,prtCmprPrtIdx}
::= {prtCmprTable 1}
PrtCmprEntry ::=
SEQUENCE {
prtCmprTypIdx Integer32,
prtCmprCnfgIdx Integer32,
prtCmprVersion Integer32,
prtCmprSltIdx INTEGER,
prtCmprPrtIdx Integer32,
prtCmprObj OCTET STRING,
prtCmprStatisticObj OCTET STRING
}
prtCmprTypIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Type of the Compressed being
referred."
::= { prtCmprEntry 1}
prtCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the configuration to which the
Compressed information is related."
::= { prtCmprEntry 2}
prtCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format of
the Compressed data"
::= { prtCmprEntry 3}
prtCmprSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number of the slot position
where the card is inserted.
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
are not valid."
::= { prtCmprEntry 4}
prtCmprPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the port
the compressed information relates to.
Valid values: exPrt1 (1) .. exPrt16 (16) ,
inPrt1 (101) .. inPrt48 (148)."
::= { prtCmprEntry 5}
prtCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { prtCmprEntry 6}
prtCmprStatisticObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is the compressed statistics information itself."
::= { prtCmprEntry 7}
-- Compressed Dlci table in the Port level
-- The only way of reading this table is by the command 'GET NEXT'
prtDlciCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDlciCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { cmprPrtGen 2 }
prtDlciCmprEntry OBJECT-TYPE
SYNTAX PrtDlciCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtDlciCmprCnfgIdx,prtDlciCmprVersion,
prtDlciCmprSltIdx,prtDlciCmprPrtIdx,prtDlciCmprDlciIdx}
::= {prtDlciCmprTable 1}
PrtDlciCmprEntry ::=
SEQUENCE {
prtDlciCmprCnfgIdx Integer32,
prtDlciCmprVersion Integer32,
prtDlciCmprSltIdx INTEGER,
prtDlciCmprPrtIdx INTEGER,
prtDlciCmprDlciIdx Integer32,
prtDlciCmprObj OCTET STRING
}
prtDlciCmprCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the configuration to which the
Compressed information is related."
::= { prtDlciCmprEntry 1}
prtDlciCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format of
the Compressed data"
::= { prtDlciCmprEntry 2}
prtDlciCmprSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique number of the slot position
where the module is inserted.
In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16)
are not valid."
::= { prtDlciCmprEntry 3}
prtDlciCmprPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110) ,
inPrt11 (111) ,
inPrt12 (112)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the port
the compressed information relates to.
All the values are valid."
::= { prtDlciCmprEntry 4}
prtDlciCmprDlciIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the Dlci
the compressed information relates to.
The values are between 16 - 991."
::= { prtDlciCmprEntry 5}
prtDlciCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { prtDlciCmprEntry 6}
-- Compressed Alarm table in the Port level
-- The only way of reading this table is by the command 'GET NEXT'
prtAlarmsCmprTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {cmprPrtGen 3}
prtAlarmsCmprEntry OBJECT-TYPE
SYNTAX PrtAlarmsCmprEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtAlarmsCmprVersion,prtAlarmsCmprAlarmSlot,
prtAlarmsCmprAlarmPort,prtAlarmsCmprAlarmIdx}
::= {prtAlarmsCmprTable 1}
PrtAlarmsCmprEntry ::=
SEQUENCE {
prtAlarmsCmprVersion Integer32,
prtAlarmsCmprAlarmSlot Integer32,
prtAlarmsCmprAlarmPort Integer32,
prtAlarmsCmprAlarmIdx Integer32,
prtAlarmsCmprObj OCTET STRING
}
prtAlarmsCmprVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the version of the internal format of
the Compressed data"
::= { prtAlarmsCmprEntry 1}
prtAlarmsCmprAlarmSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the desired slot position.
In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16)
are not valid.
For Stand-alone units, notApplicable(255) will appear."
::= { prtAlarmsCmprEntry 2}
prtAlarmsCmprAlarmPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique identifier of the port
the alarm applies to.
All the values are valid. No alarms exist for a non-existing
port. IP Bundles are considered a port too, for this matter."
::= { prtAlarmsCmprEntry 3}
prtAlarmsCmprAlarmIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify an entry in the alarm status table
of the agent."
::= { prtAlarmsCmprEntry 4}
prtAlarmsCmprObj OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is the compressed information itself."
::= { prtAlarmsCmprEntry 5}
--
-- Specific port status for each module Type
-- *****************************************
--
-- Megaplex?000/?004 port specific status for HS(TDM) modules
-- HS-2,HS-3,HS-Q, HS-6, HS-12
prtSExHsfStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSExHsfStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {statPrtMux 6}
prtSExHsfStatEntry OBJECT-TYPE
SYNTAX PrtSExHsfStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtSExHsfSltIdx, prtSExHsfPrtIdx }
::= {prtSExHsfStatTable 1}
PrtSExHsfStatEntry ::=
SEQUENCE {
prtSExHsfSltIdx INTEGER,
prtSExHsfPrtIdx INTEGER,
prtSExHsfInterfaceTyp INTEGER,
prtSExHsfRts INTEGER
}
prtSExHsfSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= { prtSExHsfStatEntry 1}
prtSExHsfPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number. "
::= { prtSExHsfStatEntry 2}
prtSExHsfInterfaceTyp OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
v35 (2),
rs422 (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique interface type of a
selected port."
::= { prtSExHsfStatEntry 3}
prtSExHsfRts OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
notActive (2),
active (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique RTS control signal state."
::= { prtSExHsfStatEntry 4}
-- ISDN Port Status
prtIsdnStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIsdnStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ISDN Statistics parameters that do not appear
in the standard MIBs or for agents that don't support the standard Index
of Call Set Up Time."
::= { statPrtMux 16 }
prtIsdnStatusEntry OBJECT-TYPE
SYNTAX PrtIsdnStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries for ISDN Statistics parameters that do not appear in the standard MIBs
or for agents that don't support the standard Index of Call Set Up Time."
INDEX { ifIndex }
::= { prtIsdnStatusTable 1 }
PrtIsdnStatusEntry ::=
SEQUENCE {
prtIsdnStatusDspMode INTEGER,
prtIsdnStatusCallState INTEGER,
prtIsdnStatusCallingNumber DisplayString,
prtIsdnStatusCalledNumber DisplayString,
prtIsdnStatusCalledIP IpAddress,
prtIsdnStatusCallDirection INTEGER
}
prtIsdnStatusDspMode OBJECT-TYPE
SYNTAX INTEGER
{
voice (2),
idle (3),
fax (4),
vbd (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DSP can be in one of the following Modes:
Voice, Idle, Fax, Voice Band Data (VBD)- Modem."
::= { prtIsdnStatusEntry 1 }
prtIsdnStatusCallState OBJECT-TYPE
SYNTAX INTEGER
{
present (2),
overlapReceive (3),
incoming (4),
receive (5),
initiated (6),
overlapSend (7),
outGoingProceed (8),
callDeliver (9),
active (10),
disconnectIndicate (11),
releaseRequest (12),
disconnectReq (13),
notActive (14)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state that the current call is in."
::= { prtIsdnStatusEntry 2 }
prtIsdnStatusCallingNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the local Number (ISDN Address) associated with this entry."
::= { prtIsdnStatusEntry 3 }
prtIsdnStatusCalledNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the remote Number (ISDN Address) associated with this entry."
::= { prtIsdnStatusEntry 4 }
prtIsdnStatusCalledIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the remote IP Address associated with this entry."
::= { prtIsdnStatusEntry 5 }
prtIsdnStatusCallDirection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
incoming (2),
outgoing (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attribute indicating the Direction of the Call.
The value of notApplicable will be used for example when
prtIsdnStatusCallState = notActive(14)."
::= { prtIsdnStatusEntry 6 }
cnfgMdlMux OBJECT IDENTIFIER ::= {mdlMux 1}
mdlPbxFramerCnfg OBJECT IDENTIFIER ::= {cnfgMdlMux 1}
mdlPbxFramerCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlPbxFramerCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters relevant to a module belonging to
a digital voice system, except mdlPbxFraEnhEcho which is relevant
also for analog cards."
::= {mdlPbxFramerCnfg 1}
mdlPbxFramerCnfgEntry OBJECT-TYPE
SYNTAX MdlPbxFramerCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlPbxFraCnfgIdx, mdlPbxFraSltIdx }
::= {mdlPbxFramerCnfgTable 1}
MdlPbxFramerCnfgEntry ::=
SEQUENCE {
mdlPbxFraCnfgIdx Integer32,
mdlPbxFraSltIdx INTEGER,
mdlPbxFraEnhEcho INTEGER,
mdlPbxFraTSGroupAss INTEGER,
mdlPbxFraSignalMode INTEGER,
mdlPbxFraSignalVector OCTET STRING,
mdlPbxFraSignalMask OCTET STRING,
mdlPbxFraFramerSlot INTEGER,
mdlPbxFraSignaling INTEGER,
mdlPbxFraTransSigTs Integer32
}
mdlPbxFraCnfgIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
-- DEFVAL {1}
::= { mdlPbxFramerCnfgEntry 1}
mdlPbxFraSltIdx OBJECT-TYPE
SYNTAX INTEGER{ io1(5), io2(6), io3(7), io4(8), io5(9),
io6(10), io7(11), io8(12), io9(13), io10(14),
io11(15), io12(16) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot relevant to this module."
::= { mdlPbxFramerCnfgEntry 2}
mdlPbxFraEnhEcho OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1) ,
disabled(2),
ms16(3),
ms32(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Refers to external ports of an analogue module
and to the internal ports of the other mvc4 types
of modules.
ms16(3) means that the four voice ports have enhanced
echo of 16ms.
ms32(4) means that the two first ports have enhanced
echo of 32 ms while the last two ports have no
enhanced echo."
::= { mdlPbxFramerCnfgEntry 3}
mdlPbxFraTSGroupAss OBJECT-TYPE
SYNTAX INTEGER{ group1(1), group2(2), group3(3), group4(4),
group5(5), group6(6), group7(7), group8(8),
notApplicable(255) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In case of T1 modules:
group1=(1,2,3,4), ...., group6=(21,22,23,24)
while in case of E1 modules:
- If prtExPh1MlLineType=g732sE1 or g732sE1CRC:
group1=(1,2,3,4),..,group4=(13,14,15,17),
group5=(18,19,20,21),...,group7=(26,27,28,29)
group8=(30,31).
- If prtExPh1MlLineType=g732nE1 or g732nE1CRC:
group1=(1,2,3,4),..,group4=(13,14,15,16),
group5=(17,18,19,20),...,group7=(25,26,27,28)
group8=(29,30,31)."
::= { mdlPbxFramerCnfgEntry 4}
mdlPbxFraSignalMode OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
tieTrunk(2),
tieInvert(3),
casTrans(4),
userDefined(5),
ccsTrans(6),
noSignaling(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Refers to the signaling mode of the Framer module.
tieTrunk(2), tieInvert(3), casTrans(4) are standard
coding of the signaling protocol.
casTrans(4) is Channel Associated Signaling (the signaling is within the
channels time slot).
ccsTrans(6) is Transparent Common Channel Signaling (the signaling is not within
the channels time slot - a TS for signaling is used).
userDefined(5) allows the user to define the signaling
protocol he wants. In this case, the next two MIB fields
are relevant."
DEFVAL { casTrans }
::= { mdlPbxFramerCnfgEntry 5}
mdlPbxFraSignalVector OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In the case of mdlPbxFraSignalMode = userDefined(5), this
field defines the A,B,C Bits. D bit is supplied for future
versions.
Bit 1 = Bit A ON Hook - Local
Bit 2 = Bit B ON Hook - Local
Bit 3 = Bit C ON Hook - Local
Bit 4 = Bit D ON Hook - Local
Bit 5 = Bit A OFF Hook - Local
Bit 6 = Bit B OFF Hook - Local
Bit 7 = Bit C OFF Hook - Local
Bit 8 = Bit D OFF Hook - Local
Bit 9 = Bit A ON Hook - Remote
Bit 10 = Bit B ON Hook - Remote
Bit 11 = Bit C ON Hook - Remote
Bit 12 = Bit D ON Hook - Remote
Bit 13 = Bit A OFF Hook - Remote
Bit 14 = Bit B OFF Hook - Remote
Bit 15 = Bit C OFF Hook - Remote
Bit 16 = Bit D OFF Hook - Remote
In conjunction with the Mask, mdlPbxFraSignalMask, it is
possible to compute the signal mode."
DEFVAL { '0000'H}
::= { mdlPbxFramerCnfgEntry 6}
mdlPbxFraSignalMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In the case of mdlPbxFraSignalMode = userDefined(5), this
field defines the 'don't care' A,B,C Bits. D bit is supplied
for future versions.
Bit 1 = Bit A ON Hook - Local
Bit 2 = Bit B ON Hook - Local
Bit 3 = Bit C ON Hook - Local
Bit 4 = Bit D ON Hook - Local
Bit 5 = Bit A OFF Hook - Local
Bit 6 = Bit B OFF Hook - Local
Bit 7 = Bit C OFF Hook - Local
Bit 8 = Bit D OFF Hook - Local
Bit 9 = Bit A ON Hook - Remote
Bit 10 = Bit B ON Hook - Remote
Bit 11 = Bit C ON Hook - Remote
Bit 12 = Bit D ON Hook - Remote
Bit 13 = Bit A OFF Hook - Remote
Bit 14 = Bit B OFF Hook - Remote
Bit 15 = Bit C OFF Hook - Remote
Bit 16 = Bit D OFF Hook - Remote."
DEFVAL { 'ffff'H }
::= { mdlPbxFramerCnfgEntry 7}
mdlPbxFraFramerSlot OBJECT-TYPE
SYNTAX INTEGER { io1(5), io2(6), io3(7), io4(8), io5(9),
io6(10), io7(11), io8(12), io9(13), io10(14),
io11(15), io12(16) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Slot where is sitting the Framer."
::= { mdlPbxFramerCnfgEntry 8}
mdlPbxFraSignaling OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
endToEnd (2),
localTermination(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signaling - describes the way the signaling ABCD bits pass from the
local extension to the remote extension and vice-versa.
endToEnd = the signaling ABCD bits pass without change from local to
remote extension.
localTermination = the signaling ABCD bits received from the local extension
are translated to different ON Hook/OFF Hook bit values and then
passed to remote extension. This is relevant when the Local
and Remote ON Hook/OFF Hook values are different."
DEFVAL { endToEnd }
::= { mdlPbxFramerCnfgEntry 9}
mdlPbxFraTransSigTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the Time Slot that is used for Transparent CCS signaling.
The values of this TS are 1-24 for T1 & 1-31 for E1.
The default for E1 is 16 & for T1 it is 24. If no signaling is used then
the TS should be 255 (None)."
::= { mdlPbxFramerCnfgEntry 10}
--Protected IP Adresses list for ML-IP cards of MP-2100/4 and MP-2200
--for IP Ring Mode
mdlProtIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlProtIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains Protected IP Addresses for ML-IP cards
when working in IP Ring Mode."
::= {cnfgMdlMux 2}
mdlProtIpEntry OBJECT-TYPE
SYNTAX MdlProtIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlProtIpCnfgIdx, mdlProtIpSlotIdx, mdlProtIpAddress}
::= {mdlProtIpTable 1}
MdlProtIpEntry ::=
SEQUENCE {
mdlProtIpCnfgIdx Integer32,
mdlProtIpSlotIdx INTEGER,
mdlProtIpAddress IpAddress,
mdlProtIpRowStatus RowStatus
}
mdlProtIpCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg being accessed.
Idx 255 relates to the TmpCnfg.
For Agents having several configuration, Write operation is
allowed only to the Temporary Configuration."
::= { mdlProtIpEntry 1}
mdlProtIpSlotIdx OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the 2104 Unit the entries io6(10)..io16) are not valid."
::= { mdlProtIpEntry 2}
mdlProtIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Protected IP address."
::= { mdlProtIpEntry 3 }
mdlProtIpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter allows creating/deleting entries of this table."
::= { mdlProtIpEntry 4 }
statMdlMux OBJECT IDENTIFIER ::= {mdlMux 2}
--
-- Card status table
--
mdlStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdlStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { statMdlMux 1 }
mdlStatEntry OBJECT-TYPE
SYNTAX MdlStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mdlStatSltIdx }
::= { mdlStatTable 1}
MdlStatEntry ::=
SEQUENCE {
mdlStatSltIdx INTEGER,
mdlStatHostIP IpAddress,
mdlStatHostMask IpAddress,
mdlStatDefaultGateway IpAddress
}
mdlStatSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
psA (1),
psB (2),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique number to identify a slot position in the mux.
In the 2104 Unit the entries psB(2),clB(4),io6(10)..io12(16)
are not valid."
::= { mdlStatEntry 1}
mdlStatHostIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The host interface IP address when DHCP Client=Yes.
This object is relevant only when DHCP Client=Yes "
::= { mdlStatEntry 2 }
mdlStatHostMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The host interface subnet mask when DHCP Client=Yes.
This object is relevant only when DHCP Client=Yes "
::= { mdlStatEntry 3 }
mdlStatDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Default Gateway's IP Address when DHCP Client=Yes.
This object is relevant only when DHCP Client=Yes "
::= { mdlStatEntry 4 }
--
-- Specific port config for each module Type
-- *****************************************
--
-- MPCL.1 configuration parameters
--
--prtExClCnfgTable OBJECT IDENTIFIER ::= {prtClCnfg 1}
-- prtInClInbandTable OBJECT IDENTIFIER ::= {prtClCnfg 2}
prtExClCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExClCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {prtClCnfg 1}
prtExClCnfgEntry OBJECT-TYPE
SYNTAX PrtExClCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All the entries at this table are identical (have the same
value) for all the configurations (1..100) except the
TmpCnfg.
The write operation into the Table Objects is valid only
to the TmpCnfg entry."
INDEX {prtExClCnfgIdx, prtExClSltIdx, prtExClPrtIdx }
::= { prtExClCnfgTable 1}
PrtExClCnfgEntry ::=
SEQUENCE {
prtExClCnfgIdx Integer32,
prtExClSltIdx INTEGER,
prtExClPrtIdx INTEGER,
prtExClUsage INTEGER,
prtExClRate INTEGER,
prtExClDataBits INTEGER,
prtExClParity INTEGER,
prtExClStopBits INTEGER,
prtExClRoutingProtocol INTEGER,
prtExClEnabled INTEGER
}
prtExClCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg."
::= { prtExClCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExClSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
clA (3),
clB (4),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted. Because the second Cl is only for
redundancy, all the parameters are identical in the two
modules, i.e. change of any parameter in one module will
change automatically the value of the other module..
In the ?004 Unit the entry clB(4) is not valid."
::= { prtExClCnfgEntry 2}
prtExClPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number. "
::= { prtExClCnfgEntry 3}
prtExClUsage OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
noUse (2),
nmsSlip (3),
nmsPpp (4),
muxSlip (5),
muxPpp (6),
terminal(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates what is the usage of the port."
::= { prtExClCnfgEntry 4}
prtExClRate OBJECT-TYPE
SYNTAX INTEGER
{
r300Bps (1),
r1200Bps (2),
r2400Bps (3),
r4800Bps (4),
r9600Bps (5),
r19200Bps (6),
r38400Bps (7),
r57600Bps (8),
r115200Bps (9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the operation rate of the port."
::= { prtExClCnfgEntry 5}
prtExClDataBits OBJECT-TYPE
SYNTAX INTEGER
{
dataBits7Bits (1),
dataBits8Bits (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the number of data bits in async
frame"
::= { prtExClCnfgEntry 6}
prtExClParity OBJECT-TYPE
SYNTAX INTEGER
{
odd (1),
even (2),
none (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates if the parity operation mode in
async frame"
::= { prtExClCnfgEntry 7}
prtExClStopBits OBJECT-TYPE
SYNTAX INTEGER
{
stopBits1Bit (1),
stopBits1dot5Bits (2),
stopBits2Bits (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the minimum number of stop bits in
the tx async frame"
::= { prtExClCnfgEntry 8}
prtExClRoutingProtocol OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
rip2 (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the routing protocol of the port.
When prtExClUsage is nmsSlip or nmsPpp - all values are
applicable .
Else - only 'none' is applicable."
::= { prtExClCnfgEntry 9}
prtExClEnabled OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates if Ethernet port of CL
is enabled or not for management.
It is applicable only on the ETH port of the CL, when the
MP includes an ML-IP card.
disabled - will happen when there is Inband Management via
the ML-IP link/s
enabled - will happen when ML-IP link/s is not used for Inband
Management, but CL's ETH port ."
::= { prtExClCnfgEntry 10}
--
-- MPH1.T1, MPH1.E1, MTML.1/T1 , MTML.1/E1, ML-20
-- TDM and Hybrid(TDM & Packet) Main Link Modules
--
--prtExPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 1}
--prtExPh1MlTsTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 2}
--prtInPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 3}
--prtInPh1MlDlciTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 4}
--prtPhMlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 5}
--
-- T1/E1 Port Objects
--
prtExPh1MlCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPh1MlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"- For products supporting more than one configuration, the write operation
into the Table is valid only to the TmpCnfg entry.
- For products that do not support configurations, the write operation
into the Table will be to prtExPh1MlCnfgIdx=1."
::= {prtPh1MlCnfg 1}
prtExPh1MlCnfgEntry OBJECT-TYPE
SYNTAX PrtExPh1MlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPh1MlCnfgIdx, prtExPh1MlSltIdx, prtExPh1MlPrtIdx }
::= { prtExPh1MlCnfgTable 1}
PrtExPh1MlCnfgEntry ::= SEQUENCE {
prtExPh1MlCnfgIdx Integer32,
prtExPh1MlSltIdx INTEGER,
prtExPh1MlPrtIdx INTEGER,
prtExPh1MlConnect INTEGER,
prtExPh1MlLineType INTEGER,
prtExPh1MlLineCode INTEGER,
prtExPh1MlLineLen INTEGER,
prtExPh1MlRestoreTime INTEGER,
prtExPh1MlTxGain INTEGER,
prtExPh1MlRxSensitivity INTEGER,
prtExPh1MlIdleCode Integer32,
prtExPh1MlTdmTrunk INTEGER,
prtExPh1MlClkMode INTEGER,
prtExPh1MlMfClkSrcSlt INTEGER,
prtExPh1MlMfClkSrcPrt INTEGER,
prtExPh1MlFdlType INTEGER,
prtExPh1MlInbandMng INTEGER,
prtExPh1MlInbandMngRate INTEGER,
prtExPh1MlRedundType INTEGER,
prtExPh1MlRedundSlot INTEGER,
prtExPh1MlRedundPort INTEGER,
prtExPh1MlRedundRecTime Integer32,
prtExPh1MlInbandMngRoutProt INTEGER,
prtExPh1MlIfType INTEGER,
prtExPh1MlMultiplier INTEGER,
prtExPh1MlSupportedTS Integer32,
prtExPh1MlImpedance INTEGER,
prtExPh1MlQ50BwControl INTEGER,
prtExPh1MlQ50SignalPair INTEGER,
prtExPh1MlInternalSwitch INTEGER,
prtExPh1MlSigService INTEGER,
prtExPh1MlFragmentSize Integer32
}
prtExPh1MlCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPh1MlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPh1MlSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid.
For the Vmux2100 Main Board notApplicable (1) is used."
::= { prtExPh1MlCnfgEntry 2}
prtExPh1MlPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
exPrt5 (5),
exPrt6 (6),
exPrt7 (7),
exPrt8 (8),
exPrt9 (9),
exPrt10 (10),
exPrt11 (11),
exPrt12 (12),
exPrt13 (13),
exPrt14 (14),
exPrt15 (15),
exPrt16 (16),
exPrt17 (17),
exPrt18 (18),
inPrt1 (101),
inPrt2 (102),
inPrt3 (103),
inPrt4 (104),
inPrt5 (105),
inPrt6 (106),
inPrt7 (107),
inPrt8 (108),
inPrt9 (109),
inPrt10 (110),
inPrt11 (111),
inPrt12 (112),
inPrt13 (113),
inPrt14 (114),
inPrt15 (115),
inPrt16 (116),
inPrt17 (117),
inPrt18 (118),
inPrt19 (119),
inPrt20 (120),
inPrt21 (121),
inPrt22 (122),
inPrt23 (123),
inPrt24 (124),
inPrt25 (125),
inPrt26 (126),
inPrt27 (127),
inPrt28 (128),
inPrt29 (129),
inPrt30 (130),
inPrt31 (131),
inPrt32 (132),
inPrt33 (133),
inPrt34 (134),
inPrt35 (135),
inPrt36 (136),
inPrt37 (137),
inPrt38 (138),
inPrt39 (139),
inPrt40 (140),
inPrt41 (141),
inPrt42 (142),
inPrt43 (143),
inPrt44 (144),
inPrt45 (145),
inPrt46 (146),
inPrt47 (147),
inPrt48 (148),
inPrt49 (149),
inPrt50 (150),
inPrt51 (151),
inPrt52 (152),
inPrt53 (153),
inPrt54 (154),
inPrt55 (155),
inPrt56 (156),
inPrt57 (157),
inPrt58 (158),
inPrt59 (159),
inPrt60 (160),
inPrt61 (161),
inPrt62 (162),
inPrt63 (163),
inPrt64 (164),
inPrt65 (165),
inPrt66 (166),
inPrt67 (167),
inPrt68 (168),
inPrt69 (169),
inPrt70 (170),
inPrt71 (171),
inPrt72 (172),
inPrt73 (173),
inPrt74 (174),
inPrt75 (175),
inPrt76 (176),
inPrt77 (177),
inPrt78 (178),
inPrt79 (179),
inPrt80 (180),
inPrt81 (181),
inPrt82 (182),
inPrt83 (183),
inPrt84 (184)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
MP-2100/2200:
MTML-1/E1 and MTML-1/T1 cards have only one external interface.
inPrt1, inPrt2 - for MTML-H/2E1 and HSH cards.
inPrt1..inPrt4 - for MTML-E2 and MSL-4 cards.
exPrt2..exPrt4 - for MTML-4 cards and others
exPrt1..exPrt8 - for ML-8 cards.
inPrt1..inPrt8 - for MSL-8 and VF-30 card family.
MP-104/204: only exPrt3 (3) is applicable.
MP-4100: intPrt1...intPrt84 - for CLX cards.
For other products' index see their specification."
::= { prtExPh1MlCnfgEntry 3}
prtExPh1MlConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered
in any of the mux algorithms. It also affects all the card
considerations because it may indicate that the module has only
one physical interface."
::= {prtExPh1MlCnfgEntry 4}
prtExPh1MlLineType OBJECT-TYPE
SYNTAX INTEGER
{
esfT1 (2), --> dsx1ESF
sfT1 (3), --> dsx1D4
g732nE1 (4), --> dsx1E1
g732nE1CRC (5), --> dsx1E1-CRC
g732sE1 (6), --> dsx1E1-MF
g732sE1CRC (7), --> dsx1E1-MF-CRC
g732unframed (8), --> dsx1Unframed, for T1 Unframed
e1Unframed (9), --> dsx1E1Unframed
framed (101)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line type parameter for T1/E1 interface.
The user should select only the values which are relevant
to the specific port:
(2),(3), (8) - for T1 port
(4)..(7), (9) - for E1 port.
(101) framed - This value does not exist in standard MIB and is used
for a non-standard E1 port that doesn't has real framer.
Note: for old devices, g732unframed(8) was used as E1 Unframed.
That was because at the time this value did not exist in
the standard MIB (RFC-1406), so we added it in private MIB.
Now that it was added to standard MIB, private MIB was
updated as well.
This parameter has the same values as dsx1LineType in DS1
MIB (RFC-3895). The parameters in dsx1LineType are:
other (1)
esfT1 dsx1ESF (2)
sfT1 dsx1D4 (3)
g732nE1 dsx1E1 (4)
g732nE1CRC dsx1E1-CRC (5)
g732sE1 dsx1E1-MF (6)
g732sE1CRC dsx1E1-MF-CRC (7)
g732unframed dsx1Unframed (8) --from RFC-3895
e1Unframed dsx1E1Unframed (9) --from RFC-3895 "
::= { prtExPh1MlCnfgEntry 5}
prtExPh1MlLineCode OBJECT-TYPE
SYNTAX INTEGER
{
b7T1 (1), --> dsx1JBZS (for E1 & T1)
b8zsT1 (2), --> dsx1B8ZS (for E1 & T1)
transT1(3), --> dsx1AMI
hdb3E1 (4), --> dsx1HDB3 (for E1 & T1)
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line code parameter used for T1/E1
interface.
The user should select only the parameters which are relevant
to the specific card:
T1 line code parameters for MPH.1/T1
E1 line code parameters for MPH.1/E1.
This parameter has the same values as dsx1LineCoding in T1/E1
MIB (RFC-1406). The parameters in dsx1LineCoding are:
dsx1JBZS (1)
dsx1B8ZS (2)
dsx1HDB3 (3)
dsx1ZBTSI (4)
dsx1AMI (5)
other (6)"
::= { prtExPh1MlCnfgEntry 6}
prtExPh1MlLineLen OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
len0p133ft (2),
len134p266ft (3),
len267p399ft (4),
len400p533ft (5),
len534p655ft (6),
lenFcc68 (7),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line length parameter used only for T1/DSU
interfaces.
lenXXXpXXXft = len-XXX-XXXft."
::= { prtExPh1MlCnfgEntry 7}
prtExPh1MlRestoreTime OBJECT-TYPE
SYNTAX INTEGER
{
restoreT1secFast (2),
restoreT10sec62411 (3),
ccittE1 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time passing from the disappearance of the loss of
synchronization condition (red alarm) to the restoration of
normal service. The options 1secFast(2) and 10sec62411(3)
for E1 interfaces are proprietary implementation of the T1
standard to the E1 interface."
::= { prtExPh1MlCnfgEntry 8}
prtExPh1MlTxGain OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
txGain0db (2),
txGain7dot5db (3),
txGain15db (4),
txGain22dot5db (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the tx gain parameter used only for
T1/CSU interfaces."
::= { prtExPh1MlCnfgEntry 9}
prtExPh1MlRxSensitivity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
low26dBm (2),
high36dBm (3),
shortHaul (4),
longHaul (5),
low15dbm (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the rx line sensitivity parameter.
low26dBm, high36dBm - applicable for T1-CSU
shortHaul, longHaul - applicable for MTML-4 cards
low15dbm was added for vmux110/210 T1 ports."
::= { prtExPh1MlCnfgEntry 10}
prtExPh1MlIdleCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the code for transmission in empty time slots.
Type value(00-FFH), Excluding 0H,8H,10H,12H,21H,24H,42H,49H,
84H,92H"
::= { prtExPh1MlCnfgEntry 11}
prtExPh1MlTdmTrunk OBJECT-TYPE
SYNTAX INTEGER
{
linkA (1),
linkB (2),
none (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port is used to transfer
TDM cards data and through which Bus."
::= {prtExPh1MlCnfgEntry 12}
prtExPh1MlClkMode OBJECT-TYPE
SYNTAX INTEGER
{
internalLocal (1),
loopBackLocal (2),
nodalTiming (3),
loopBackFromLink (4),
loopBackFromChannel (5),
loopbackFromSystem (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the clock operation mode of the T1/E1 interface.
Ports that are connected to the TDM Buses must be in
nodalTiming(3) clock mode. "
::= {prtExPh1MlCnfgEntry 13}
prtExPh1MlMfClkSrcSlt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
local (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port Tx multiframe is
synchronized with Rx multiframe of another port and the slot
position of that port.
This operation is required in order to bypass signaling of
PCM voice channels. Its value is always local(2) when the port
isn't connected to any TDM bus. When it's value is local(2)
there is no meaning to 'prtExPh1MlMfClkSrcPrt' parameter.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= {prtExPh1MlCnfgEntry 14}
prtExPh1MlMfClkSrcPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
inPrt1 (101),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify a port position in the mux. It
has no effect when the prtExPh1MlMfClkSrcSlt selected is Local.
inPrt1 - for MTML-H/E1 cards."
::= {prtExPh1MlCnfgEntry 15}
prtExPh1MlFdlType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
response (2),
command (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify the side of the FDL operation.
Normal: 'response' for the user side and 'command' for the PTT
side.
Applicable only when working with ESF-T1 link"
::= {prtExPh1MlCnfgEntry 16}
prtExPh1MlInbandMng OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
fdlOrTs0 (3),
dedicatedTs (4),
dedicatedPpp (5),
dedicatedFr (6),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify an Inband management over the
link."
::= {prtExPh1MlCnfgEntry 17}
prtExPh1MlInbandMngRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
r4k (2),
r8k (3),
r12k (4),
r16k (5),
r32k (6),
r64k (7),
r20k (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify the rate of the Inband
management (Kbps).
E1 port - it is not applicable when prtExPh1MlInbandMng
selected is off.
T1 port - it is not applicable when prtExPh1MlInbandMng
selected is off OR fdlOrTs0."
::= {prtExPh1MlCnfgEntry 18}
prtExPh1MlRedundType OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
dualCableAIS (2),
yCable (3),
dualCableParallelTx (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the ML redundancy type:
none - no ML redundacy
dualCableAIS - each ML card is connected by a separate
dualCableParallelTx cable to the other MUX (two cables
connect two MUXes). There are two
types of dual redundancy.
yCable - Y cable is connected to both ML cards (one cable
connects two MUXes).
Default=none
When only one ML card exists, the type can be only 'none'.
The value should be the same for both ML slots."
::= {prtExPh1MlCnfgEntry 19}
prtExPh1MlRedundSlot OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the slot containing the redundacy ML
card, coupled with the current ML (prtExPh1MlSltIdx).
When prtExPh1MlRedundType=none (no ML redundancy) this
object will be 'notApplicable'.
In the ?004 Unit the entries io6(10)..io12(16) are not valid
When value is not 'none', it should be mutual to the
redundant ML slot."
::= {prtExPh1MlCnfgEntry 20}
prtExPh1MlRedundPort OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
inPrt1 (101),
inPrt2 (102),
inPrt3 (103),
inPrt4 (104),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the redundacy ML port, coupled with the
current ML port (prtExPh1MlPrtIdx).
When prtExPh1MlRedundType=none (no ML redundancy) this
object will be 'notApplicable'.
When value is not 'none', it should be mutual to the
redundant ML port.
inPrt1 - for MTML-H/E1 cards.
inPrt1..inPrt4 - for MTML-E2 cards.
exPrt2..exPrt4 - for MTML-4 cards."
::= {prtExPh1MlCnfgEntry 21}
prtExPh1MlRedundRecTime OBJECT-TYPE
SYNTAX Integer32 (1..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Redundancy Recovery Time (sec). After switching the ML card
to the current (prtExPh1MlSltIdx), the next ML switch can
be performed only after a minimum time, indicated by
this object."
::= {prtExPh1MlCnfgEntry 22}
prtExPh1MlInbandMngRoutProt OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
rip2 (2),
proprietary (3),
proprietaryNoNmsTx (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Inband Mng routing protocol of
the port."
::= {prtExPh1MlCnfgEntry 23}
prtExPh1MlIfType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
csu (2),
dsu (3),
ltu (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interface type of the port.
For T1 - csu, dsu are the valid values
For E1 - dsu, ltu are the valid values."
::= {prtExPh1MlCnfgEntry 24}
prtExPh1MlMultiplier OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
br56 (2),
br64 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The data rate of each TS. The multiplier values
can be 56 kbps or 64 kbps."
::= {prtExPh1MlCnfgEntry 25}
prtExPh1MlSupportedTS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Supported Time Slots by the agent.
For Vmux-110 there is HW that supports less than 31/24
Time Slots for the E1/T1 port."
::= {prtExPh1MlCnfgEntry 26}
prtExPh1MlImpedance OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
unbalanced (2),
balanced (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Line Impedance.
For T1 (always balanced), impedance is 100 ohm.
For E1:
- balanced = 120 ohm
- unbalanced = 75 ohm."
::= {prtExPh1MlCnfgEntry 27}
prtExPh1MlQ50BwControl OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
annexA (3),
annexB (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables configuration of Q.50 Bandwidth Control on the port.
If the bandwidth exceeds a certain threshold it is possible to disable
new calls in the PBX via Q.50 protocol.
Q.50 supports only E1 ports with Line Types:
E1-MF (G.732S), E1-CRC-MF(G.732SCRC )
It does not support T1 ports.
Annex A - the basic type of Q.50 which focuses only on the bandwidth control.
Can use one of the following pairs of signaling bits: A&B or C&D.
Annex B - Expansion of Annex A which includes also call release messages
and Maintenance Messages. Uses A&B bits only."
::= {prtExPh1MlCnfgEntry 28}
prtExPh1MlQ50SignalPair OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
aAndB (2),
cAndD (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Q.50 Signaling bits Pair that is currently in use:
A&B bits or C&D bits. For Annex B it will always be: aAndB (2)."
::= {prtExPh1MlCnfgEntry 29}
prtExPh1MlInternalSwitch OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter shows whether the data will be transferred from one port to
the other port within the same group of 2 ports.
The default value is: Enable.
Disable value might be necessary for security implementations or
for ring applications.
For Vmux-2100 device this parameter is used on the Channelized Cards.
Both ports in each group should have the same value for this parameter."
::= {prtExPh1MlCnfgEntry 30}
prtExPh1MlSigService OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
normal (2),
advanced (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signaling Service given by this link.
notApplicable - for T1 links
normal - usual Signaling
advanced - V5 Signaling. "
::= {prtExPh1MlCnfgEntry 31}
prtExPh1MlFragmentSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the maximum number of bytes permitted in a packet send over the Link.
Exceeding this size will cause packet fragmentation."
::= {prtExPh1MlCnfgEntry 32}
--
-- MPH1.T1 & MPH1.E1
-- Time Slot Assignment Table
--
prtExPh1MlTsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPh1MlTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry, except prtExPh1MlTsTest that will be written
directly to the Active Configuration."
::= {prtPh1MlCnfg 2}
prtExPh1MlTsEntry OBJECT-TYPE
SYNTAX PrtExPh1MlTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPh1MlTsCnfgIdx, prtExPh1MlTsSltIdx, prtExPh1MlTsPrtIdx, prtExPh1MlTsIdx }
::= { prtExPh1MlTsTable 1}
PrtExPh1MlTsEntry ::=
SEQUENCE {
prtExPh1MlTsCnfgIdx Integer32,
prtExPh1MlTsSltIdx INTEGER,
prtExPh1MlTsPrtIdx INTEGER,
prtExPh1MlTsIdx Integer32,
prtExPh1MlTsIConSlot INTEGER,
prtExPh1MlTsIConPrt Integer32,
prtExPh1MlTsIConTs Integer32,
prtExPh1MlTsExt OBJECT IDENTIFIER,
prtExPh1MlTsTest INTEGER,
prtExPh1MlTsType INTEGER,
prtExPh1MlTsBundle Integer32,
prtExPh1MlTsTestDuration Integer32,
prtExPh1MlTsSubChType INTEGER,
prtExPh1MlTsSubChMask Integer32,
prtExPh1MlTsChRate INTEGER,
prtExPh1MlTsByteReversal INTEGER,
prtExPh1MlTsSigProfile INTEGER
}
prtExPh1MlTsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPh1MlTsEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPh1MlTsSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid.
For the Vmux2100 Main Board notApplicable (255) is used."
::= { prtExPh1MlTsEntry 2}
prtExPh1MlTsPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
exPrt5 (5),
exPrt6 (6),
exPrt7 (7),
exPrt8 (8),
exPrt9 (9),
exPrt10 (10),
exPrt11 (11),
exPrt12 (12),
exPrt13 (13),
exPrt14 (14),
exPrt15 (15),
exPrt16 (16),
exPrt17 (17),
exPrt18 (18),
inPrt1 (101),
inPrt2 (102),
inPrt3 (103),
inPrt4 (104),
inPrt5 (105),
inPrt6 (106),
inPrt7 (107),
inPrt8 (108),
inPrt9 (109),
inPrt10 (110),
inPrt11 (111),
inPrt12 (112),
inPrt13 (113),
inPrt14 (114),
inPrt15 (115),
inPrt16 (116),
inPrt17 (117),
inPrt18 (118),
inPrt19 (119),
inPrt20 (120) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
MPH.1/E1 and MPH.1/T1 cards have only one external interface.
exPrt2 - for ME1-2, MT1-2 and mhsPri cards.
exPrt3, exPrt4 - for mhsPri cards.
inPrt1 - for MTML-H/E1 cards."
::= { prtExPh1MlTsEntry 3}
prtExPh1MlTsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are 1..24 for T1 Card and
1..31 for E1 interface. In G732S-E1 lines time slot 16 is not
valid for data, it is dedicated for multiframe synchronization bits
and voice signaling."
::= { prtExPh1MlTsEntry 4}
prtExPh1MlTsIConSlot OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
noConnect (2),
split (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the specified time slot is
connected/routed internally in the Agent and to which card
it is connected.
In the ?004 Unit the entries io6(10)..io16) are not valid.
split - will be used when the Src TS is connected to more
than one slot OR more than one port (each needing
less than a whole TS)."
::= {prtExPh1MlTsEntry 5}
prtExPh1MlTsIConPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the internally (In Mux)
connected/routed port.
For MP, the values will be:
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
noConnect (100),
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110) ,
inPrt11 (111) ,
inPrt12 (112)
}
For other products see specific values at spec."
::= {prtExPh1MlTsEntry 6}
prtExPh1MlTsIConTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are 1..24 for T1 Card and
1..31 for E1 interface. In G732S-E1 lines time slot 16 is not
valid for data, it is dedicated to multiframe synchronization
and voice signaling."
::= {prtExPh1MlTsEntry 7}
prtExPh1MlTsExt OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A pointer to an extension of this table:
prtExTsSplitTable.
- If prtExPh1MlTsIConSlot='split', its value
should be set to the OBJECT IDENTIFIER of the
prtExTsSplitTable, with its relevant CnfgIdx,
SltIdx, PrtIdx, TsIdx and 1st TsBit.
- If prtExPh1MlTsIConSlot is not 'split', its value
should be set to the OBJECT IDENTIFIER { 0 0 }. "
::= { prtExPh1MlTsEntry 8 }
prtExPh1MlTsTest OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
localLoop (2),
remoteLoop (3),
remoteBert (8), -- BERT
localToneInjection (9),
remoteToneInjection (18),
localBert (30),
split (254),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a test to be activated on the selected TS.
It is applicable only when prtSTstCmd=testPerTS(31).
notApplicable - when prtSTstCmd is NOT testPerTS(31).
none - no test is applied for the selected TS.
split - when the tests are per Bit of the selected TS."
::= { prtExPh1MlTsEntry 9 }
prtExPh1MlTsType OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
data (3),
voice (4),
cas (5),
ss7 (6),
transparent (7),
data2 (8),
data3 (9),
data4 (10),
ss7n2 (11),
hdlcV2Compatible (12),
subCh1 (13),
subCh2 (14),
subCh3 (15),
subCh4 (16),
subCh5 (17),
subCh6 (18),
subCh7 (19),
subCh8 (20),
trau (21),
qmux (22),
dynamic (23),
signaling (24),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Time Slot Type.
Transparent - means that the Time Slot will be Rx/Tx as is without processing it.
If the device requires more than 1 unique data or ss7 Time Slot,
options with numbers can be used like: data...data4.
Each numbered Type can go to a different destination.
ss7n2 - means the 2nd group of ss7 Time Slots.
data2,data3, data4 mean group 2,3,4 of Data Time Slots.
subCh1...subCh8 mean Sub Channel 1...8, respectively.
trau, qmux, dynamic, signaling - are used by GSM devices."
::= { prtExPh1MlTsEntry 10 }
prtExPh1MlTsBundle OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the bundle containing this Time Slot.
If no bundle exists for this TS or the bundle number
is irrelevant, the value will be 0."
::= { prtExPh1MlTsEntry 11 }
prtExPh1MlTsTestDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the maximum duration of executing
a test on the specific TS. This entry applies to all the
test operations.
For the Vmux2100 the values are:
0 - 60 seconds.
A zero value specifies no time limitation.
When the test isn't active, the agent initiates this object to
2 when the duration is needed and to 0 if its not required.
The user should set this parameter after setting the
'prtExPh1MlTsTest' parameter."
::= { prtExPh1MlTsEntry 12 }
prtExPh1MlTsSubChType OBJECT-TYPE
SYNTAX INTEGER
{
hdlc (1),
transparent (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Time Slot Sub-Channel Type.
This variable is relevant only when Time-Slot Type is SubCh
(e.g. prtExPh1MlTsType = subCh1...subCh8)."
::= { prtExPh1MlTsEntry 13 }
prtExPh1MlTsSubChMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Sub-Channel Type Mask.
This variable is relevant only when Time-Slot Type is SubCh
(e.g. prtExPh1MlTsType = subCh1...subCh8)."
::= { prtExPh1MlTsEntry 14 }
prtExPh1MlTsChRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
r16Kbps (2),
r32Kbps (3),
r64Kbps (4),
r8Kbps (5),
auto (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Rate of the Signaling Channel.
notApplicable(1) when TS Type is other than Signaling or Transparent"
::= { prtExPh1MlTsEntry 15 }
prtExPh1MlTsByteReversal OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Byte Reversal.
This variable defines whether the LSB or MSB is transmitted first.
no(2) - MSB is transmitted first
yes(3) - LSB is transmitted first."
::= { prtExPh1MlTsEntry 16 }
prtExPh1MlTsSigProfile OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
-- none (2),
p1 (3),
p2 (4),
p3 (5),
p4 (6),
p5 (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Signaling Profile of the port.
It is applicable only when prtMl4SigProfile=perTS.
p1 = profile 1
p2 = profile 2
p3 = profile 3
p4 = profile 4
p5 = profile 5 "
::= { prtExPh1MlTsEntry 17 }
--
-- MPH.1/T1 & MPH.1/E1
-- Internal port objects table
-- (only for the Hybrid modules)
--
prtInPh1MlCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInPh1MlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtPh1MlCnfg 3}
prtInPh1MlCnfgEntry OBJECT-TYPE
SYNTAX PrtInPh1MlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInPh1MlCnfgIdx, prtInPh1MlSltType, prtInPh1MlPrtIdx }
::= { prtInPh1MlCnfgTable 1}
PrtInPh1MlCnfgEntry ::=
SEQUENCE {
prtInPh1MlCnfgIdx Integer32,
prtInPh1MlSltType INTEGER,
prtInPh1MlPrtIdx Integer32,
prtInPh1MlConnect INTEGER,
prtInPh1MlRate INTEGER,
prtInPh1MlProtocol INTEGER,
prtInPh1MlConnectionTyp INTEGER,
prtInPh1MlCongResponse INTEGER,
prtInPh1MlCongLevel Integer32,
prtInPh1MlTc INTEGER,
prtInPh1MlFlowControl INTEGER,
prtInPh1MlSegment INTEGER,
prtInPh1MlFrMngProt INTEGER,
prtInPh1MlEnqPeriod Integer32,
prtInPh1MlFullRptPeriod Integer32,
prtInPh1MlFrWindowSize Integer32,
prtInPh1MlErrorsThreshold Integer32,
prtInPh1MlMaxIdleTime Integer32,
prtInPh1MlBearerCh INTEGER,
prtInPh1MlAssociatedExCh INTEGER,
prtInPh1MlClockEncoding INTEGER,
prtInPh1MlMinSeparators Integer32,
prtInPh1MlCcittCrc INTEGER,
prtInPh1MlFrameSeparator INTEGER
}
prtInPh1MlCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtInPh1MlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtInPh1MlSltType OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
For ISDN BRI port of MX300/30:
io1(5) = isdn1(5) and io2(6) = isdn2(6)
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
::= { prtInPh1MlCnfgEntry 2}
prtInPh1MlPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
MPH.1/E1 and MPH.1/T1 cards have three internal interfaces.
MX3000 modules may have up to 50 internal ports."
::= { prtInPh1MlCnfgEntry 3}
prtInPh1MlConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= { prtInPh1MlCnfgEntry 4}
prtInPh1MlRate OBJECT-TYPE
SYNTAX INTEGER
{
r1x56eq56Kbps (1),
r1x64eq64Kbps (2),
r2x56eq112Kbps (3),
r2x64eq128Kbps (4),
r3x56eq168Kbps (5),
r3x64eq192Kbps (6),
r4x56eq224Kbps (7),
r4x64eq256Kbps (8),
r5x56eq280Kbps (9),
r5x64eq320Kbps (10),
r6x56eq336Kbps (11),
r6x64eq384Kbps (12),
r7x56eq392Kbps (13),
r7x64eq448Kbps (14),
r8x56eq448Kbps (15),
r8x64eq512Kbps (16),
r9x56eq504Kbps (17),
r9x64eq576Kbps (18),
r10x56eq560Kbps (19),
r10x64eq640Kbps (20),
r11x56eq616Kbps (21),
r11x64eq704Kbps (22),
r12x56eq672Kbps (23),
r12x64eq768Kbps (24),
r13x56eq728Kbps (25),
r13x64eq832Kbps (26),
r14x56eq784Kbps (27),
r14x64eq896Kbps (28),
r15x56eq840Kbps (29),
r15x64eq960Kbps (30),
r16x56eq896Kbps (31),
r16x64eq1024Kbps(32),
r17x56eq952Kbps (33),
r17x64eq1088Kbps(34),
r18x56eq1008Kbps(35),
r18x64eq1152Kbps(36),
r19x56eq1064Kbps(37),
r19x64eq1216Kbps(38),
r20x56eq1120Kbps(39),
r20x64eq1280Kbps(40),
r21x56eq1176Kbps(41),
r21x64eq1344Kbps(42),
r22x56eq1232Kbps(43),
r22x64eq1408Kbps(44),
r23x56eq1288Kbps(45),
r23x64eq1472Kbps(46),
r24x56eq1344Kbps(47),
r24x64eq1536Kbps(48),
r25x56eq1400Kbps(49),
r25x64eq1600Kbps(50),
r26x56eq1456Kbps(51),
r26x64eq1664Kbps(52),
r27x56eq1512Kbps(53),
r27x64eq1728Kbps(54),
r28x56eq1568Kbps(55),
r28x64eq1792Kbps(56),
r29x56eq1624Kbps(57),
r29x64eq1856Kbps(58),
r30x56eq1680Kbps(59),
r30x64eq1920Kbps(60),
r31x56eq1736Kbps(61),
r31x64eq1984Kbps(62),
r32x56eq1792Kbps(63),
r32x64eq2048Kbps(64),
r1x1dot5eq1dot5M(65),
r2x1dot5eq3M (66),
r3x1dot5eq4dot5M(67),
r4x1dot5eq6M (68),
r5x1dot5eq7dot5M(69),
r6x1dot5eq9M (70),
r7x1dot5eq10dot5M(71),
r8x1dot5eq12M (72),
r1x2Meq2M (73),
r2x2Meq4M (74),
r3x2Meq6M (75),
r4x2Meq8M (76),
r5x2Meq10M (77),
r6x2Meq12M (78),
r7x2Meq14M (79),
r8x2Meq16M (80),
noRate (100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed. "
::= { prtInPh1MlCnfgEntry 5}
prtInPh1MlProtocol OBJECT-TYPE
SYNTAX INTEGER
{
fr (1),
frPlus (2),
pCellRelay (3),
hdlcSdlc (4),
transparentHdlc (5),
ciscoBridgedEth (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the applied protocol."
::= { prtInPh1MlCnfgEntry 6}
prtInPh1MlConnectionTyp OBJECT-TYPE
SYNTAX INTEGER
{
sameNetManaged (1),
sameNetNotMana (2),
user (3),
otherNet (4),
pubNet (5),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the link connection type.
It is required for three reasons:
FR/CR Inband management operation (LMI,CLMM...).
CIR check.
NMS network management.
SameNetManaged - indicates network internal line.
SameNetNotMana - indicates network internal line, but the remote
mux is not managed by the nms.
User - User to Network Interface.
OtherNet - Network To Network Interfce.
PubNet - Access Mux To PubNet Interface."
::= { prtInPh1MlCnfgEntry 7}
prtInPh1MlCongResponse OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
flowControl (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates how to handle the congestion indication
to/from the mux internal connection side (for example
transmit/receive becn to/from the network).
no - do nothing
FlowControl - translate the congestion indication between the
port and the internal connection port according to
the definition of the prtInPh1MlFlowControl
parameters. The operation is done in both directions."
::= { prtInPh1MlCnfgEntry 8}
prtInPh1MlCongLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the level of delayed data in
precents of the total available dynamic memory,
for which the port will start to operate .
The resolution of the parameter is 5 percent.
Valid values: 10..70, 255.
255=notApplicable."
::= { prtInPh1MlCnfgEntry 9}
prtInPh1MlTc OBJECT-TYPE
SYNTAX INTEGER
{
tc1sec (1),
tc2sec (2),
tc3sec (3),
tc4sec (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Tc parameter which is the time
period of the sliding window in which the Bc/Be are tested.
The value of this parameter is identical for all the ports in the
specific card.
255=notApplicable."
::= { prtInPh1MlCnfgEntry 10}
prtInPh1MlFlowControl OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
fecnBecn (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the required flow control betweeen
the port and the remote equipment."
::= { prtInPh1MlCnfgEntry 11}
prtInPh1MlSegment OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
s36Byte (2),
s150Byte (3),
s264Byte (4),
s378Byte (5),
s492Byte (6),
s236Byte (7),
s472Byte (8),
s708Byte (9),
s944Byte (10),
s1180Byte (11)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Segmentation in Bytes.
In protocol FR+, ISDN internals, MX 30/300 the segmentation is:
50 (2) ,158 (3) ,266 (4) ,376 (5), 484 (6)
In MX 3000/4:
For protocol FR+ (internal ISDN ports of MHS.S, MHS.U, MHS.E1, MHS.T1
cards) segmentation values are:
236 (7),472 (8), 708 (9), 944 (10) ,1180 (11)"
::= { prtInPh1MlCnfgEntry 12}
prtInPh1MlFrMngProt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
lmi (3),
ansiT1 (4), --Annex D
annexA (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Frame-Relay management protocol.
ansiT1 = ANSI T1.617 Annex D (this is the default value).
This parameter is applicable only for FR and FR+ protocols.
When prtInPh1MlConnectionTyp = sameNetManaged, this object
will be RO (internally determined). "
::= { prtInPh1MlCnfgEntry 13}
prtInPh1MlEnqPeriod OBJECT-TYPE
SYNTAX Integer32 (0..30)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Status Enquiry Period, in seconds.
It determines the frequency of the Status Enquiry message
as sent by the FR user side.
At the FR network side, it determines the timeout for this
message reception.
Default = 4 seconds.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
0=notApplicable."
::= { prtInPh1MlCnfgEntry 14}
prtInPh1MlFullRptPeriod OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Full Report Frequency.
It determines the number of the Status Enquiry messages
sent by the FR user side, before a Full Report Request is
sent.
The units are : Status Enquiry messages (periods).
Valid values: 1 .. 255.
255 = infinite (never sent).
This parameter is applicable only for FR and FR+ protocols
AND
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
0=notApplicable."
::= { prtInPh1MlCnfgEntry 15}
prtInPh1MlFrWindowSize OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the FR Window Size.
It determines the number of samplings in the sliding window
that counts the errors.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
0=notApplicable."
::= { prtInPh1MlCnfgEntry 16}
prtInPh1MlErrorsThreshold OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Max Errors.
It determines the number of Status Enquiry Errors that
occured within the FR sliding window, before this port is
considered DOWN (threshold).
This parameter is applicable only for FR and FR+ protocols
AND
only when prtInPh1MlFrMngProt is NOT (notApplicable or none).
0=notApplicable. "
::= { prtInPh1MlCnfgEntry 17}
prtInPh1MlMaxIdleTime OBJECT-TYPE
SYNTAX Integer32 (0..1800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Move to higher prioritized connected link after this period of
seconds of silence on the current link.
0=Never. Never move to higher prioritized connected link.
UNIT is seconds.
Valid values are: 0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 120, 180, 240, 300,
360, 420, 480, 540, 600, 900, 1200, 1500, 1800.
Attempt to Set an invalid value will result in getting the default value."
DEFVAL { 10 }
::= {prtInPh1MlCnfgEntry 18}
prtInPh1MlBearerCh OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
channelB1 (3),
channelB2 (4),
chB1andchB2 (5),
none (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines which B (bearer) channels are used for transferring ISDN data.
Default value is: none (255).
anyChannel (2) is skipped because it is not in use here."
::= {prtInPh1MlCnfgEntry 19}
prtInPh1MlAssociatedExCh OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the external port associated to this internal
port. At present, it is used by the Hybrid (mp2100h), MHS-4 cards which
can have up to 64 dynamic internal ports associated with External ports.
For ISDN cards, the value will be: notApplicable (255).
The associated external of an ISDN internal port is represented
by the MIB object: prtIsdnDirectoryPrtNu."
::= { prtInPh1MlCnfgEntry 20}
prtInPh1MlClockEncoding OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
nrz (2),
nrzI (3),
fm0 (4),
manchester (5),
diffManchester(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Encoding type of the Line.
This parameter is applicable only for FR and FR+ protocols."
::= { prtInPh1MlCnfgEntry 21}
prtInPh1MlMinSeparators OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum number of bytes separating between two adjacent frames (HDLC item).
0 = notApplicable"
::= { prtInPh1MlCnfgEntry 22}
prtInPh1MlCcittCrc OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
crc16 (2),
crc32 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates how many Bits are used for CRC (HDLC item)."
::= { prtInPh1MlCnfgEntry 23}
prtInPh1MlFrameSeparator OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
idles (2),
flags (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates what should be transferred on the line when there
are no frames to pass (HDLC item).
idles: mean that FF will pass on the line
flags: mean that 7E will pass on the line."
::= { prtInPh1MlCnfgEntry 24}
--
-- MPH1.T1 & MPH1.E1
-- Internal port Dlci objects table
--
prtInPh1MlDlciTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInPh1MlDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtPh1MlCnfg 4}
prtInPh1MlDlciEntry OBJECT-TYPE
SYNTAX PrtInPh1MlDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInPh1MlDlciCnfgIdx, prtInPh1MlDlciSltIdx, prtInPh1MlDlciPrtIdx, prtInPh1MlDlciIdx }
::= { prtInPh1MlDlciTable 1}
PrtInPh1MlDlciEntry ::=
SEQUENCE {
prtInPh1MlDlciCnfgIdx Integer32,
prtInPh1MlDlciSltIdx INTEGER,
prtInPh1MlDlciPrtIdx INTEGER,
prtInPh1MlDlciIdx Integer32,
prtInPh1MlDlciValid INTEGER,
prtInPh1MlDlciIConSlt INTEGER,
prtInPh1MlDlciIConPrt INTEGER,
prtInPh1MlDlciIConDlci Integer32,
prtInPh1MlDlciTxBc INTEGER,
prtInPh1MlDlciTxBe INTEGER,
prtInPh1MlDlciRxBc INTEGER,
prtInPh1MlDlciRxBe INTEGER,
prtInPh1MlDlciPriority Integer32,
prtInPh1MlDlciStatus INTEGER
}
prtInPh1MlDlciCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtInPh1MlDlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtInPh1MlDlciSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtInPh1MlDlciEntry 2}
prtInPh1MlDlciPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal port number.
MPH.1/E1 and MPH.1/T1 cards have three internal ports."
::= { prtInPh1MlDlciEntry 3}
prtInPh1MlDlciIdx OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique index for each possible
used dlci(16..991). When the protocol is not Multiplexing
protocol, then its type is 'user' and the only valid index
is 1."
::= { prtInPh1MlDlciEntry 4}
prtInPh1MlDlciValid OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the attributes in this entry
are valid or not. The user can add/delete pvc (dlci to dlci
connection) by modifing this object"
::= { prtInPh1MlDlciEntry 5}
prtInPh1MlDlciIConSlt OBJECT-TYPE
SYNTAX INTEGER
{
noConnect(2),
cl (3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position In the Mux
(Agent) where the dlci is routed to.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtInPh1MlDlciEntry 6}
prtInPh1MlDlciIConPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
clNMS (99) ,
noConnect (100),
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110) ,
inPrt11 (111) ,
inPrt12 (112)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port id which the dlci is
routed to."
::= { prtInPh1MlDlciEntry 7}
prtInPh1MlDlciIConDlci OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique internal connection dlci
number which the src dlci is routed to."
::= { prtInPh1MlDlciEntry 8}
prtInPh1MlDlciTxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBc9600bps (3),
txBc14200bps (4),
txBc19200bps (5),
txBc28800bps (6),
txBc32000bps (7),
txBc38400bps (8),
txBc48000bps (9),
txBc56000bps (10),
txBc57600bps (11),
txBc64Kbps (12),
txBc128Kbps (13),
txBc192Kbps (14),
txBc256Kbps (15),
txBc320Kbps (16),
txBc384Kbps (17),
txBc448Kbps (18),
txBc512Kbps (19),
txBc768Kbps (20),
txBc1024Kbps (21)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx committed bandwidth on
the user transmit line or at the port receive line."
::= { prtInPh1MlDlciEntry 9}
prtInPh1MlDlciTxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBe9600bps (3),
txBe14200bps (4),
txBe19200bps (5),
txBe28800bps (6),
txBe32000bps (7),
txBe38400bps (8),
txBe48000bps (9),
txBe56000bps (10),
txBe57600bps (11),
txBe64Kbps (12),
txBe128Kbps (13),
txBe192Kbps (14),
txBe256Kbps (15),
txBe320Kbps (16),
txBe384Kbps (17),
txBe448Kbps (18),
txBe512Kbps (19),
txBe768Kbps (20),
txBe1024Kbps (21)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx excess bandwidth on the
user transmit line or at the port receive line."
::= { prtInPh1MlDlciEntry 10}
prtInPh1MlDlciRxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBc9600bps (3),
rxBc14200bps (4),
rxBc19200bps (5),
rxBc28800bps (6),
rxBc32000bps (7),
rxBc38400bps (8),
rxBc48000bps (9),
rxBc56000bps (10),
rxBc57600bps (11),
rxBc64Kbps (12),
rxBc128Kbps (13),
rxBc192Kbps (14),
rxBc256Kbps (15),
rxBc320Kbps (16),
rxBc384Kbps (17),
rxBc448Kbps (18),
rxBc512Kbps (19),
rxBc768Kbps (20),
rxBc1024Kbps (21)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx committed bandwidth on
the user receive line or at the port transmit line."
::= { prtInPh1MlDlciEntry 11}
prtInPh1MlDlciRxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBe9600bps (3),
rxBe14200bps (4),
rxBe19200bps (5),
rxBe28800bps (6),
rxBe32000bps (7),
rxBe38400bps (8),
rxBe48000bps (9),
rxBe56000bps (10),
rxBe57600bps (11),
rxBe64Kbps (12),
rxBe128Kbps (13),
rxBe192Kbps (14),
rxBe256Kbps (15),
rxBe320Kbps (16),
rxBe384Kbps (17),
rxBe448Kbps (18),
rxBe512Kbps (19),
rxBe768Kbps (20),
rxBe1024Kbps (21)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx excess bandwidth on the
user receive line or at the port transmit line."
::= { prtInPh1MlDlciEntry 12}
prtInPh1MlDlciPriority OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique priority of the pcv.
1 is the lowest priority and 8 is the highest priority."
::= { prtInPh1MlDlciEntry 13}
prtInPh1MlDlciStatus OBJECT-TYPE
SYNTAX INTEGER
{
disconnected (1),
connected (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the pvc. The status is
disconnected(1) when one of the sides is programmed as
not connected"
::= { prtInPh1MlDlciEntry 14}
--
-- ML-20 - High Speed Main Link card
-- External Port Objects
--
prtPhMlCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPhMlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtPh1MlCnfg 5}
prtPhMlCnfgEntry OBJECT-TYPE
SYNTAX PrtPhMlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtPhMlCnfgIdx, prtPhMlSltIdx, prtPhMlPrtIdx }
::= { prtPhMlCnfgTable 1}
PrtPhMlCnfgEntry ::=
SEQUENCE {
prtPhMlCnfgIdx Integer32,
prtPhMlSltIdx INTEGER,
prtPhMlPrtIdx INTEGER,
prtPhMlConnect INTEGER,
prtPhMlRate INTEGER,
prtPhMlCAS INTEGER,
prtPhMlClockMode INTEGER,
prtPhMlSatBuffer INTEGER,
prtPhMlDialProcess INTEGER,
prtPhMlSyncRestore Integer32,
prtPhMlBus INTEGER,
prtPhMlMfSyncSlot INTEGER,
prtPhMlClockSource INTEGER,
prtPhMlErrCorrection INTEGER,
prtPhMlCorrectionMode INTEGER,
prtPhMlControlSignals INTEGER,
prtPhMlInterfaceType INTEGER,
prtPhMlClockPolarity INTEGER
}
prtPhMlCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtPhMlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtPhMlSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
For the Vmux2100 Main Board notApplicable (1) is used."
::= { prtPhMlCnfgEntry 2}
prtPhMlPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
ML-20 cards have just one external interface."
::= { prtPhMlCnfgEntry 3}
prtPhMlConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered
in any of the mux algorithms."
::= {prtPhMlCnfgEntry 4}
prtPhMlRate OBJECT-TYPE
SYNTAX INTEGER
{
r1x64eq64Kbps (2),
r2x64eq128Kbps (4),
r3x64eq192Kbps (6),
r4x64eq256Kbps (8),
r5x64eq320Kbps (10),
r6x64eq384Kbps (12),
r7x64eq448Kbps (14),
r8x64eq512Kbps (16),
r9x64eq576Kbps (18),
r10x64eq640Kbps (20),
r11x64eq704Kbps (22),
r12x64eq768Kbps (24),
r13x64eq832Kbps (26),
r14x64eq896Kbps (28),
r15x64eq960Kbps (30),
r16x64eq1024Kbps(32),
r17x64eq1088Kbps(34),
r18x64eq1152Kbps(36),
r19x64eq1216Kbps(38),
r20x64eq1280Kbps(40),
r21x64eq1344Kbps(42),
r22x64eq1408Kbps(44),
r23x64eq1472Kbps(46),
r24x64eq1536Kbps(48),
r25x64eq1600Kbps(50),
r26x64eq1664Kbps(52),
r27x64eq1728Kbps(54),
r28x64eq1792Kbps(56),
r29x64eq1856Kbps(58),
r30x64eq1920Kbps(60),
r31x64eq1984Kbps(62),
r32x64eq2048Kbps(64),
auto (70)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the configured port speed.
auto - rate is adapted automatically to the attached modem rate."
::= {prtPhMlCnfgEntry 5}
prtPhMlCAS OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether Channel Associated
Signaling (CAS) is used."
::= {prtPhMlCnfgEntry 6}
prtPhMlClockMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (2),
ext-dce (3),
dte (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock mode."
::= { prtPhMlCnfgEntry 7}
prtPhMlSatBuffer OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Satellite Buffer (+/- 256)."
::= {prtPhMlCnfgEntry 8}
prtPhMlDialProcess OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
callIn (3),
callOut (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Dial Process."
::= {prtPhMlCnfgEntry 9}
prtPhMlSyncRestore OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sync Restoration time, in seconds.
notApplicable=0. "
::= {prtPhMlCnfgEntry 10}
prtPhMlBus OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
busA (2),
busB (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TDM BUS this port is linked to."
::= {prtPhMlCnfgEntry 11}
prtPhMlMfSyncSlot OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the sync is synchronized
according to a certain card and the slot of this card.
This operation is required in order to bypass signaling of
PCM voice channels.
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
::= {prtPhMlCnfgEntry 12}
prtPhMlClockSource OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
txClock (2),
rxClock (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Clock Source: TC (Tx Clock) or RC (Rx Clock) signals."
::= {prtPhMlCnfgEntry 13}
prtPhMlErrCorrection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if Error Correction mechanism should be applied or not.
It will be applicable only if the interface HW includes the Error Correction
chip."
::= {prtPhMlCnfgEntry 14}
prtPhMlCorrectionMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
random (2),
bursty (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only when prtPhMlErrCorrection=yes.
random - enables to correct up to 3 random errors in an 23 bit frame
built from 12 data bits and 11 appended parity bits.
bursty - interleaving 3 frames, allows correcting bursts of 9 bit length."
::= {prtPhMlCnfgEntry 15}
prtPhMlControlSignals OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ignore (2),
implement (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows whether the Port will ignore or implement the control signals
like DCD, CTS, DTR."
::= {prtPhMlCnfgEntry 16}
prtPhMlInterfaceType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
v35 (2),
x21 (3), -- v.11
rs232 (4), -- v.28
rs449 (5),
ei530 (6),
ei530a (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SW Configurable Interface Type."
::= {prtPhMlCnfgEntry 17}
prtPhMlClockPolarity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
inverted (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the clock polarity."
::= {prtPhMlCnfgEntry 18}
-- This table is an extension for new version of MAXcess
-- modules.
prtLogicalCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtLogicalCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLogicalCnfg 1}
prtLogicalCnfgEntry OBJECT-TYPE
SYNTAX PrtLogicalCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtLogicalCnfgIdx, prtLogicalSltIdx, prtLogicalPrtIdx }
::= { prtLogicalCnfgTable 1}
PrtLogicalCnfgEntry ::=
SEQUENCE {
prtLogicalCnfgIdx Integer32,
prtLogicalSltIdx INTEGER,
prtLogicalPrtIdx Integer32,
prtLogicalConnect INTEGER,
prtLogicalFunction INTEGER,
prtLogicalRowStatus RowStatus
}
prtLogicalCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtLogicalCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtLogicalSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index.
For ISDN BRI Ports of MX300/30,
io1(5) = isdn1(5) and io2(6) = isdn2(6)."
::= { prtLogicalCnfgEntry 2}
prtLogicalPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
This port number should be an internal port number:
inPrt1(101)->inPrt50(150), linkSel1(200)->linkSel50(250),
encaps1(300)-> encaps50(350), huntGr1(101) -> huntGr10(110)."
::= { prtLogicalCnfgEntry 3}
prtLogicalConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered
in any of the mux algorithms."
::= { prtLogicalCnfgEntry 4}
prtLogicalFunction OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
linkSelector(2),
encapsulator(3),
huntGroup(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter defines the function of the relevant channel."
::= { prtLogicalCnfgEntry 5 }
prtLogicalRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter allows the NMS to create/delete logical ports.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { prtLogicalCnfgEntry 6 }
-- This group contains management information for the
-- link selector function.
linkSelectorCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkSelectorCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtLogicalCnfg 2}
linkSelectorCnfgEntry OBJECT-TYPE
SYNTAX LinkSelectorCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {linkSelectorCnfgIdx, linkSelectorSltIdx, linkSelectorPrtIdx }
::= { linkSelectorCnfgTable 1}
LinkSelectorCnfgEntry ::=
SEQUENCE {
linkSelectorCnfgIdx Integer32,
linkSelectorSltIdx INTEGER,
linkSelectorPrtIdx Integer32,
linkSelectorMaxIdleTime Integer32,
linkSelectorMode INTEGER,
linkSelectorRevert INTEGER,
linkSelectorMinBUSession Integer32
}
linkSelectorCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of
the Cnfg (1..100) being accessed.
Idx 255 relates to the TmpCnfg. "
::= { linkSelectorCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
linkSelectorSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index"
::= { linkSelectorCnfgEntry 2}
linkSelectorPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
This port number should be internal port number:
higher or equal to linkSeL1(201)."
::= { linkSelectorCnfgEntry 3}
linkSelectorMaxIdleTime OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Move to higher prioritized connected link
after this period of seconds of silence on the current link.
0=move immediately to higher prioritized connected link.
UNIT is seconds."
DEFVAL { 0 }
::= {linkSelectorCnfgEntry 4}
linkSelectorMode OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
backup(2), bod(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" If the link selector is in mode:
backup(2)=then the link with the lower priority will be
used in case of failure of the higher priority link,
bod(3)=bandwidth on demand or dynamic bandwidth allocation
means that links with lower priority will be used
whenever additional bandwidth is required. "
DEFVAL { backup }
::= {linkSelectorCnfgEntry 5}
linkSelectorRevert OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
auto(2), manual(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" If the link selector is in mode backup:
auto(2)=return automatically to Main link when it is OK.
manual(3)=stays connected to backup link."
DEFVAL { auto }
::= {linkSelectorCnfgEntry 6}
linkSelectorMinBUSession OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum duration of a backup session before
returning to Main Link. Relevant in Backup Mode and
when Revert is auto(2). Value 255 is for NEVER which
means never return to Main Link.
UNIT is minutes."
DEFVAL { 10 }
::= {linkSelectorCnfgEntry 7}
-- Prioritized Links
linkSelectorPLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkSelectorPLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtLogicalCnfg 3}
linkSelectorPLinkEntry OBJECT-TYPE
SYNTAX LinkSelectorPLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {pLinkCnfgIdx, pLinkSltIdx, pLinkPrtIdx, pLinkIdx }
::= { linkSelectorPLinkTable 1}
LinkSelectorPLinkEntry ::=
SEQUENCE {
pLinkCnfgIdx Integer32,
pLinkSltIdx INTEGER,
pLinkPrtIdx Integer32,
pLinkIdx Integer32,
pLinkSlotNu INTEGER,
pLinkPortNu Integer32,
pLinkPrioNu Integer32,
pLinkVRate INTEGER
}
pLinkCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { linkSelectorPLinkEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
pLinkSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index"
::= { linkSelectorPLinkEntry 2}
pLinkPrtIdx OBJECT-TYPE
SYNTAX Integer32(200..250)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
This port number should be the link selector number."
::= { linkSelectorPLinkEntry 3}
pLinkIdx OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This index is the row number."
::= { linkSelectorPLinkEntry 4}
pLinkSlotNu OBJECT-TYPE
SYNTAX INTEGER {
noConnect (2), cl(3),
io1(5),
io2(6),
io3(7),
io4(8),
io5(9),
io6(10),
io7(11),
io8(12),
io9(13),
io10(14),
io11(15),
io12(16),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The slot of the prioritized link.
For ISDN BRI ports of MX300/30,
io1(5) = isdn1(5) and io2(6) = isdn2(6)."
DEFVAL { noConnect }
::= { linkSelectorPLinkEntry 5 }
pLinkPortNu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port of the prioritized link.
Value 100 is for noConnect."
DEFVAL { 100 }
::= { linkSelectorPLinkEntry 6 }
pLinkPrioNu OBJECT-TYPE
SYNTAX Integer32(1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The priority of the prioritized link.
MIN=1...., MAX=8."
::= { linkSelectorPLinkEntry 7 }
pLinkVRate OBJECT-TYPE
SYNTAX INTEGER {
r1x56eq56Kbps (1),
r1x64eq64Kbps (2),
r2x56eq112Kbps (3),
r2x64eq128Kbps (4),
r3x56eq168Kbps (5),
r3x64eq192Kbps (6),
r4x56eq224Kbps (7),
r4x64eq256Kbps (8),
r5x56eq280Kbps (9),
r5x64eq320Kbps (10),
r6x56eq336Kbps (11),
r6x64eq384Kbps (12),
r7x56eq392Kbps (13),
r7x64eq448Kbps (14),
r8x56eq448Kbps (15),
r8x64eq512Kbps (16),
r9x56eq504Kbps (17),
r9x64eq576Kbps (18),
r10x56eq560Kbps (19),
r10x64eq640Kbps (20),
r11x56eq616Kbps (21),
r11x64eq704Kbps (22),
r12x56eq672Kbps (23),
r12x64eq768Kbps (24),
r13x56eq728Kbps (25),
r13x64eq832Kbps (26),
r14x56eq784Kbps (27),
r14x64eq896Kbps (28),
r15x56eq840Kbps (29),
r15x64eq960Kbps (30),
r16x56eq896Kbps (31),
r16x64eq1024Kbps(32),
r17x56eq952Kbps (33),
r17x64eq1088Kbps(34),
r18x56eq1008Kbps(35),
r18x64eq1152Kbps(36),
r19x56eq1064Kbps(37),
r19x64eq1216Kbps(38),
r20x56eq1120Kbps(39),
r20x64eq1280Kbps(40),
r21x56eq1176Kbps(41),
r21x64eq1344Kbps(42),
r22x56eq1232Kbps(43),
r22x64eq1408Kbps(44),
r23x56eq1288Kbps(45),
r23x64eq1472Kbps(46),
r24x56eq1344Kbps(47),
r24x64eq1536Kbps(48),
r25x56eq1400Kbps(49),
r25x64eq1600Kbps(50),
r26x56eq1456Kbps(51),
r26x64eq1664Kbps(52),
r27x56eq1512Kbps(53),
r27x64eq1728Kbps(54),
r28x56eq1568Kbps(55),
r28x64eq1792Kbps(56),
r29x56eq1624Kbps(57),
r29x64eq1856Kbps(58),
r30x56eq1680Kbps(59),
r30x64eq1920Kbps(60),
r31x56eq1736Kbps(61),
r31x64eq1984Kbps(62),
noRate(100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The rate to use with this link."
DEFVAL { noRate }
::= { linkSelectorPLinkEntry 8 }
--
-- Megaplex or Kilomux ?000/?004 MPH.1/3 High speed packet data cards.
-- Megaplex or Kilomux ?000/?004 MPL.6 Low speed packet data cards.
-- (Mph1, Mph3, Mpl6)
-- Maxcess 3000/3004 MLS-3/6, MHS-1/3
--
-- prtExPhPlCnfgTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 1}
-- prtExPhPlDlciTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 2}
-- prtExPhPlModemTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 3}
-- Mph.1 Mph.3 Mpl.6/ Kphs.1 Kphs.3 Mls.3 Mls.6 Mhs.1 Mhs.3
-- External port objects table
prtExPhPlCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPhPlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The write operation into the Table Objects is
valid only to the TmpCnfg entry."
::= {prtPhPlCnfg 1}
prtExPhPlCnfgEntry OBJECT-TYPE
SYNTAX PrtExPhPlCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPhPlCnfgIdx, prtExPhPlSltIdx, prtExPhPlPrtIdx}
::= { prtExPhPlCnfgTable 1}
PrtExPhPlCnfgEntry ::=
SEQUENCE {
prtExPhPlCnfgIdx Integer32,
prtExPhPlSltIdx INTEGER,
prtExPhPlPrtIdx INTEGER,
prtExPhPlConnect INTEGER,
prtExPhPlHRate INTEGER,
prtExPhPlLRate INTEGER,
prtExPhPlProtocol INTEGER,
prtExPhPlConnectionTyp INTEGER,
prtExPhPlClkMode INTEGER,
prtExPhPlDceClkSrc INTEGER,
prtExPhPlCongResponse INTEGER,
prtExPhPlCongLevel Integer32,
prtExPhPlTc INTEGER,
prtExPhPlFlowControl INTEGER,
prtExPhPlDcdRts INTEGER,
prtExPhPlDcdRtsControlPath INTEGER,
prtExPhPlDataBits INTEGER,
prtExPhPlParity INTEGER,
prtExPhPlStopBits INTEGER,
prtExPhPlLXon Integer32,
prtExPhPlLXoff Integer32,
prtExPhPlFrMngProt INTEGER,
prtExPhPlEnqPeriod Integer32,
prtExPhPlFullRptPeriod Integer32,
prtExPhPlFrWindowSize Integer32,
prtExPhPlErrorsThreshold Integer32,
prtExPhPlPvcCreateMsg INTEGER,
prtExPhPlCllmMsg INTEGER,
prtExPhPlProtDelayLevel INTEGER,
prtExPhPlClockEncoding INTEGER,
prtExPhPlMinSeparators Integer32,
prtExPhPlCcittCrc INTEGER,
prtExPhPlFrameSeparator INTEGER,
prtExPhPlIdleCode Integer32,
prtExPhPlJitter Integer32
}
prtExPhPlCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPhPlCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPhPlSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
::= { prtExPhPlCnfgEntry 2}
prtExPhPlPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
In case of PH.1 card, only exPrt(1) is valid."
::= { prtExPhPlCnfgEntry 3}
prtExPhPlConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered
in any of the mux algorithms."
::= { prtExPhPlCnfgEntry 4}
prtExPhPlHRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
r32KbpsNLE (2),
r48KbpsNLE (3),
r56KbpsNLE (4),
r64KbpsNLE (5),
r112KbpsNLE (6),
r128KbpsNLE (7),
r168KbpsNLE (8),
r192KbpsNLE (9),
r224KbpsNLE (10),
r256KbpsNLE (11),
r280KbpsE (12),
r320KbpsE (13),
r336KbpsNLE (14),
r384KbpsNLE (15),
r392KbpsE (16),
r448KbpsNLE (17),
r504KbpsLE (18), -- r504KbpsE
r512KbpsE (19), -- r512KbpsNLE
r560KbpsE (20),
r576KbpsLE (21), -- r576KbpsE
r616KbpsE (22),
r640KbpsE (23),
r672KbpsNLE (24),
r704KbpsE (25),
r728KbpsE (26),
r768KbpsNLE (27),
r784KbpsE (28),
r832KbpsE (29),
r840KbpsE (30),
r896KbpsNLE (31),
r952KbpsE (32),
r960KbpsE (33),
r1008KbpsLE (34), -- r1008KbpsE
r1024KbpsE (35), -- r1024KbpsNLE
r1064KbpsE (36),
r1088KbpsE (37),
r1120KbpsE (38),
r1152KbpsLE (39), -- r1152KbpsE
r1176KbpsE (40),
r1216KbpsE (41),
r1232KbpsE (42),
r1280KbpsE (43),
r1288KbpsE (44),
r1344KbpsNLE (45),
r1400KbpsE (46),
r1408KbpsE (47),
r1456KbpsE (48),
r1472KbpsE (49),
r1512KbpsE (50),
r1536KbpsE (51), -- r1536KbpsNLE
r1568KbpsE (52),
r1600KbpsE (53),
r1624KbpsE (54),
r1664KbpsE (55),
r1680KbpsE (56),
r1728KbpsE (57),
r1736KbpsE (58),
r1792KbpsNLE (59),
r1856KbpsE (60),
r1920KbpsE (61),
r1984KbpsE (62),
r2048KbpsE (63), -- r2048KbpsNLE
--
-- Additional rates for: MAXcess, MP2100h
--
r9d6KbpsNLE (65),
r14d4KbpsNLE (66),
r16KbpsNLE (67),
r19d2KbpsNLE (68),
r28d8KbpsNLE (69),
r38d4KbpsNLE (70),
r57d6KbpsNLE (71), -- For Mx 30/300 Only
r115d2KbpsNLE (72), -- For Mx 30/300 Only
r24000bps (73)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed for HIGH speed cards.
The card has limitations about the maximum sigma channel
speeds and about the possible rates for each clock mode .
N - The rate is valid for DCE and EXT-DCE Nodal clock mode.
L - The rate is valid for DCE and EXT-DCE Local clock mode.
E - The rate is valid for DTE External clock mode.
'r9d6KbpsNLE' means rate of 9.6 Kbps ('d'=dot).
Note: Some rate attributes have been changed. As the MIB was already
released with the old attributes, the names of the options were
not changed. The new names + attributes are in a comment.
Example: r2048KbpsE (63), -- r2048KbpsNLE"
::= { prtExPhPlCnfgEntry 5}
prtExPhPlLRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
r300bpsNLE (2),
r600bpsNLE (3),
r800bpsNLE (4),
r1200bpsNLE (5),
r2400bpsNLE (6),
r4800bpsNLE (7),
r9600bpsNLE (8),
r14400bpsLE (9), -- r14400bpsNLE
r19200bpsNLE (10),
r28800bpsLE (11), -- r28800bpsNLE
r32000bpsNLE (12),
r38400bpsNLE (13),
r48000bpsNLE (14),
r56000bpsNLE (15),
r57600bpsLE (16), -- r57600bpsNLE
r64000bpsNLE (17),
r112000bps (18), -- For Mx 30/300 Only: r112000bpsNLE
r115200bps (19), -- For Mx 30/300 Only: r115200bpsNLE
--
-- additional rates
--
r16000bpsNLE (20),
r100bpsNLE (21), -- For Mx 30/300 Only
r128000bps (22), -- For Mx 30/300 Only
r24000bps (23)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed for LOW speed cards.
The card has limitations about the possible rates for each
clock mode.
N - The rate is valid for DCE and EXT-DCE Nodal clock mode.
L - The rate is valid for DCE and EXT-DCE Local clock mode.
E - The rate is valid for DTE External clock mode.
Note: Some rate attributes have been changed. As the MIB was already
released with the old attributes, the names of the options were
not changed. The new names + attributes are in a comment.
Example: r57600bpsLE (16), -- r57600bpsNLE "
::= { prtExPhPlCnfgEntry 6}
prtExPhPlProtocol OBJECT-TYPE
SYNTAX INTEGER
{
fr (1),
frPlus (2),
pCellRelay (3),
hdlcSdlc (4),
transparentHdlc (5),
async (6),
asyncReliable (7),
activePPP (8),
slip (9),
pppAgent (10),
slipAgent (11),
transparent (12),
sna (13),
ft1Dot2 (14) -- Standard IEC 870-5-1 for Frame Transport
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the applied protocol."
::= { prtExPhPlCnfgEntry 7}
prtExPhPlConnectionTyp OBJECT-TYPE
SYNTAX INTEGER
{
sameNetManaged (1),
sameNetNotMana (2),
user (3),
otherNet (4),
pubNet (5),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the link connection type.
It is required for three reasons:
FR/CR Inband management opration (LMI,CLMM...).
CIR check.
NMS network management.
SameNetManaged - indicates network internal line.
SameNetMotMana - indicates network internal line, but the
remote mux is not managed by the NMS.
User - User to Network Interface.
OtherNet - Network To Network Interface.
PubNet - Access Mux To PubNet Interface."
::= { prtExPhPlCnfgEntry 8}
prtExPhPlClkMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
extDce (2),
dte (3),
int (4),
lbt (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock mode."
::= { prtExPhPlCnfgEntry 9}
prtExPhPlDceClkSrc OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
local (2),
nodalTiming (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the source of the clock when working
in dce or ext-dce clock mode.
notApplicable(1) - is applied for dte(3) and lbt(5) clock modes.
When clock mode is dte, the clock source is
always external, therefore this object's value is
notApplicable.
local(2) and nodalTiming(3) - are valid in dce(1), extDce(2)
or int(4) clock modes.
The recommended clock source is local(2)."
::= { prtExPhPlCnfgEntry 10}
prtExPhPlCongResponse OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
flowControl (3), -- duplex, to/from flow control
toFlowControl (4) -- simplex , only to flow control
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates how to handle the congestion indication
to/from the mux internal connection side (for example
transmit/received becn to/from the network).
no - do nothing
flowControl - translates the congestion indication between the
port and the internal connection port according
to the definition of the prtInPh1MlFlowControl
parameters. The operation is done on both
directions.
toFlowControl- translates the backward congestion indication
received from the internal connection port
(normally the network side) to flow control and
do nothing in the other direction."
::= { prtExPhPlCnfgEntry 11}
prtExPhPlCongLevel OBJECT-TYPE
SYNTAX Integer32 (0..70)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the level of delayed data in
precents of total available dynamic memory,
for which the port will start to operate as congested.
The resolution of the parameter is 5 percent."
::= { prtExPhPlCnfgEntry 12}
prtExPhPlTc OBJECT-TYPE
SYNTAX INTEGER
{
tc1sec (1),
tc2sec (2),
tc3sec (3),
tc4sec (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Tc parameter which is the time
period of the sliding window in which the Bc/Be are tested.
The value of this parameter is identical for all the ports
of a specific card ."
::= { prtExPhPlCnfgEntry 13}
prtExPhPlFlowControl OBJECT-TYPE
SYNTAX INTEGER
{
none (2),
fecnBecn (3),
xonXoff (4),
dtrCts (5),
speedReduction (6) -- simplex response only congestion to flow control
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the required flow control betweeen
the port and the remote equipment.
fecnBecn - is valid only for FR, FR+ and CR protocols.
xonXoff,dtrCts - are valid only for Async protocols.
speedReduction - is valid only for DLC protocol when the
Clock Mode is DCE and the Clock Source is
Local."
::= { prtExPhPlCnfgEntry 14}
prtExPhPlDcdRts OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2),
endToEnd (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protocol may require end to end connect indication over the
network. End to end link connection establishment over the
FR network will be indicated to the user by using DCD or
RTS control signals, depending on the clock mode: DCE or
DTE respectively.
The options are :
- On :
DCD(DCE)/RTS(DTE) will be constantly ON no matter
if the End to End connection is established or not.
- End to End:
The DCD(DCE)/RTS(DTE) will be according to the status
of the End to End connection."
::= { prtExPhPlCnfgEntry 15}
prtExPhPlDcdRtsControlPath OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protocol may require end to end connect indication over the
network. This parameter defines whether to take the user
connection status (RTS(DCE)/DCD(DTE)) and forward it to the
network side.
- on : Transmit active connection to the network regardless
the RTS/DCD control lines status.
- off: Transmit active connection to the network according
to the status of the RTS/DCD pin. "
::= { prtExPhPlCnfgEntry 16}
prtExPhPlDataBits OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
dataBits7Bits (2),
dataBits8Bits (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the number of data bits in async
frame.
It is relevant only for Async protocols."
::= { prtExPhPlCnfgEntry 17}
prtExPhPlParity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
odd (2),
even (3),
none (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the parity operation mode in
async frame.
It is relevant only for Async protocols."
::= { prtExPhPlCnfgEntry 18}
prtExPhPlStopBits OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
sb1Bit (2),
sb1dot5Bits (3),
sb2Bits (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the minimum number of stop bits
in the tx async frame.
It is relevant only for Async protocols."
::= { prtExPhPlCnfgEntry 19}
prtExPhPlLXon OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the character used as X-On to
notify receive enable.
This parameter is valid only for async protocols.
Valid values: 0..255.
The value 256 indicates that it's not applicable "
::= { prtExPhPlCnfgEntry 20}
prtExPhPlLXoff OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the character used as X-Off to
notify receive disable.
This parameter is valid only for async protocols.
Valid values: 0..255.
The value 256 indicates that it's not applicable "
::= { prtExPhPlCnfgEntry 21}
prtExPhPlFrMngProt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
lmi (3),
ansiT1 (4), --Annex D
annexA (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Frame-Relay management protocol.
ansiT1 = ANSI T1.617 Annex D (this is the default value).
This parameter is applicable only for FR and FR+ protocols.
When prtExPhPlConnectionTyp = sameNetManaged, this object
will be RO (internally determined). "
::= { prtExPhPlCnfgEntry 22}
prtExPhPlEnqPeriod OBJECT-TYPE
SYNTAX Integer32 (1..30)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Status Enquiry Period, in seconds.
It determines the frequency of the Status Enquiry message
as sent by the FR user side.
At the FR network side, it determines the timeout for this
message reception.
Default = 4 seconds.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 23}
prtExPhPlFullRptPeriod OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Full Report Frequency.
It determines the number of the Status Enquiry messages
sent by the FR user side, before a Full Report Request is
sent.
The units are : Status Enquiry messages (periods).
Valid values: 1 .. 255.
255 = infinite.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 24}
prtExPhPlFrWindowSize OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the FR Window Size.
It determines the number of samplings in the sliding window
that counts the errors.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 25}
prtExPhPlErrorsThreshold OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Max Errors.
It determines the number of Status Enquiry Errors that
occured within the FR sliding window, before this port is
considered DOWN (threshold).
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 26}
prtExPhPlPvcCreateMsg OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is Update Message (if required or not).
It determines whether a message of a New PVC Creation is
requested or not (yes/no).
Default = no.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 27}
prtExPhPlCllmMsg OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is CLLM Message (if required or not).
It determines whether to send (or not) a congestion message
when the port is Rx congested.
Default = no.
This parameter is applicable only for FR and FR+ protocols
AND
only when prtExPhPlFrMngProt is NOT (notApplicable or none)."
::= { prtExPhPlCnfgEntry 28}
prtExPhPlProtDelayLevel OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
s36Byte (2), --level 1
s150Byte (3), --level 2
s264Byte (4), --level 3
s378Byte (5), --level 4
s492Byte (6) --level 5
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Segmentation in Bytes.
In some cases, the enumerated values will mean
other segmentation values than specified:
Product: MX-3000 MX-3000 MX-300/MX-30
Protocol: FR+ Transparent FR+
-----------------------------------------------------
level 1 50 Bytes 44 Bytes 50 Bytes
level 2 158 Bytes 155 Bytes 158 Bytes
level 3 266 Bytes 266 Bytes 266 Bytes
level 4 376 Bytes 377 Bytes 376 Bytes
level 5 484 Bytes 488 Bytes 484 Bytes
Defval=level 1 value
This parameter is applicable only for FR+ and
transparent protocols."
::= { prtExPhPlCnfgEntry 29}
prtExPhPlClockEncoding OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
nrz (2),
nrzI (3),
fm0 (4),
manchester (5),
diffManchester(6),
nrzISpace (7),
nrzIMark (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the Encoding type of the Line.
This parameter is applicable only for FR and FR+ protocols.
For MAXCESS 3000 & MP2100H: when setting to nrzI (3) the nrzI works
as nrzI Mark.
For MAXCESS 30/300 when setting to nrzI (3) the nrzI works as nrzI Space."
::= { prtExPhPlCnfgEntry 30}
prtExPhPlMinSeparators OBJECT-TYPE
SYNTAX Integer32 (0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum number of bytes separating between two adjacent frames (HDLC item).
0 = notApplicable"
::= { prtExPhPlCnfgEntry 31}
prtExPhPlCcittCrc OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
crc16 (2),
crc32 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates how many Bits are used for CRC (HDLC item)."
::= { prtExPhPlCnfgEntry 32}
prtExPhPlFrameSeparator OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
idles (2),
flags (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates what should be transferred on the line when there
are no frames to pass (HDLC item).
idles: mean that FF will pass on the line
flags: mean that 7E will pass on the line."
::= { prtExPhPlCnfgEntry 33}
prtExPhPlIdleCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the code for transmission when there are no frames to transmit
on the line. The value should be 0 to FFH."
::= { prtExPhPlCnfgEntry 34}
prtExPhPlJitter OBJECT-TYPE
SYNTAX Integer32 (0..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum variant delay of the FR network, in msec."
::= { prtExPhPlCnfgEntry 35}
--
-- PH.1 & PH.3
-- External port Dlci table
--
prtExPhPlDlciTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPhPlDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
at the TmpCnfg entry."
::= {prtPhPlCnfg 2}
prtExPhPlDlciEntry OBJECT-TYPE
SYNTAX PrtExPhPlDlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPhPlDlciCnfgIdx, prtExPhPlDlciSltIdx, prtExPhPlDlciPrtIdx, prtExPhPlDlciIdx }
::= { prtExPhPlDlciTable 1}
PrtExPhPlDlciEntry ::=
SEQUENCE {
prtExPhPlDlciCnfgIdx Integer32,
prtExPhPlDlciSltIdx INTEGER,
prtExPhPlDlciPrtIdx INTEGER,
prtExPhPlDlciIdx Integer32,
prtExPhPlDlciValid INTEGER,
prtExPhPlDlciIConSlt INTEGER,
prtExPhPlDlciIConPrt INTEGER,
prtExPhPlDlciIConDlci Integer32,
prtExPhPlDlciTxBc INTEGER,
prtExPhPlDlciTxBe INTEGER,
prtExPhPlDlciRxBc INTEGER,
prtExPhPlDlciRxBe INTEGER,
prtExPhPlDlciPriority Integer32,
prtExPhPlDlciStatus INTEGER
}
prtExPhPlDlciCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPhPlDlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPhPlDlciSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtExPhPlDlciEntry 2}
prtExPhPlDlciPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal port number.
PH.1/E1 and PH.1/T1 cards have three internal ports.
Stand-alone units may have six such ports."
::= { prtExPhPlDlciEntry 3}
prtExPhPlDlciIdx OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique index for each possible
used dlci(16..991). When the protocol is not Multiplexing
protocol, its type is 'user' and the only valid index is 1."
::= { prtExPhPlDlciEntry 4}
prtExPhPlDlciValid OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the attributes in this
entry are valid or not. The user can add/delete pvc (dlci
to dlci connection) by modifing this object"
::= { prtExPhPlDlciEntry 5}
prtExPhPlDlciIConSlt OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
cl (3),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position In the Mux
(Agent) where the dlci is routed to.
cl - will represent any of the CL slots. This value can be
selected for multiple DLCIs of the product.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtExPhPlDlciEntry 6}
prtExPhPlDlciIConPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
clNMS (99),
noConnect (100),
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port id which the dlci is
routed to.
clNMS - will be used for NMS SNMP messages. It can be any
port of the CL card.
This value will be selectable only if
prtExPhPlDlciIConSlt='cl' or 'notApplicable'."
::= { prtExPhPlDlciEntry 7}
prtExPhPlDlciIConDlci OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique internal connection dlci
number, the dlci is routed to."
::= { prtExPhPlDlciEntry 8}
prtExPhPlDlciTxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBc9600bps (3),
txBc14400bps (4),
txBc19200bps (5),
txBc28800bps (6),
txBc32000bps (7),
txBc38400bps (8),
txBc48000bps (9),
txBc56000bps (10),
txBc57600bps (11),
txBc64Kbps (12),
txBc128Kbps (13),
txBc192Kbps (14),
txBc256Kbps (15),
txBc320Kbps (16),
txBc384Kbps (17),
txBc448Kbps (18),
txBc512Kbps (19),
txBc768Kbps (20),
txBc1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
txBc16000bps (25),
txBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx committed bandwidth on
the user transmit line (or at the port receive line)."
::= { prtExPhPlDlciEntry 9}
prtExPhPlDlciTxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBe9600bps (3),
txBe14400bps (4),
txBe19200bps (5),
txBe28800bps (6),
txBe32000bps (7),
txBe38400bps (8),
txBe48000bps (9),
txBe56000bps (10),
txBe57600bps (11),
txBe64Kbps (12),
txBe128Kbps (13),
txBe192Kbps (14),
txBe256Kbps (15),
txBe320Kbps (16),
txBe384Kbps (17),
txBe448Kbps (18),
txBe512Kbps (19),
txBe768Kbps (20),
txBe1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
txBc16000bps (25),
txBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx excess bandwidth on the
user transmit line (or at the port receive line)."
::= { prtExPhPlDlciEntry 10}
prtExPhPlDlciRxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBc9600bps (3),
rxBc14400bps (4),
rxBc19200bps (5),
rxBc28800bps (6),
rxBc32000bps (7),
rxBc38400bps (8),
rxBc48000bps (9),
rxBc56000bps (10),
rxBc57600bps (11),
rxBc64Kbps (12),
rxBc128Kbps (13),
rxBc192Kbps (14),
rxBc256Kbps (15),
rxBc320Kbps (16),
rxBc384Kbps (17),
rxBc448Kbps (18),
rxBc512Kbps (19),
rxBc768Kbps (20),
rxBc1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
rxBc16000bps (25),
rxBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx committed bandwidth on the
user receive line (or at the port transmit line)."
::= { prtExPhPlDlciEntry 11}
prtExPhPlDlciRxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBe9600bps (3),
rxBe14400bps (4),
rxBe19200bps (5),
rxBe28800bps (6),
rxBe32000bps (7),
rxBe38400bps (8),
rxBe48000bps (9),
rxBe56000bps (10),
rxBe57600bps (11),
rxBe64Kbps (12),
rxBe128Kbps (13),
rxBe192Kbps (14),
rxBe256Kbps (15),
rxBe320Kbps (16),
rxBe384Kbps (17),
rxBe448Kbps (18),
rxBe512Kbps (19),
rxBe768Kbps (20),
rxBe1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
rxBc16000bps (25),
rxBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx excess bandwidth on the
user receive line (or at the port transmit line)."
::= { prtExPhPlDlciEntry 12}
prtExPhPlDlciPriority OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique priority of the pcv.
1 is the lowest priority and 8 is the highest priority."
::= { prtExPhPlDlciEntry 13}
prtExPhPlDlciStatus OBJECT-TYPE
SYNTAX INTEGER
{
disconnected (1),
connected (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the pvc. The status is
disconnected(1) when one of the sides is programmed as not
connected"
::= { prtExPhPlDlciEntry 14}
-- Parameters of an external Modem which is connected to a High/Low Speed
-- Port.
prtExPhPlModemTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPhPlModemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "External Modem Parameters.
The write operation into the
Table Objects is valid only for the TmpCnfg entry."
::= {prtPhPlCnfg 3}
prtExPhPlModemEntry OBJECT-TYPE
SYNTAX PrtExPhPlModemEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPhPlModemCnfgIdx,prtExPhPlModemSltIdx,prtExPhPlModemPrtIdx}
::= { prtExPhPlModemTable 1}
PrtExPhPlModemEntry ::=
SEQUENCE {
prtExPhPlModemCnfgIdx Integer32,
prtExPhPlModemSltIdx INTEGER,
prtExPhPlModemPrtIdx INTEGER,
prtExPhPlModemStatus INTEGER,
prtExPhPlModemActivate INTEGER,
prtExPhPlModemMaxIdleTime Integer32,
prtExPhPlModemTimeBtwnCalls Integer32,
prtExPhPlModemCallDelay Integer32
}
prtExPhPlModemCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPhPlModemEntry 1}
prtExPhPlModemSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
::= { prtExPhPlModemEntry 2}
prtExPhPlModemPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
In case of PH.1 card, only exPrt(1) is valid."
::= { prtExPhPlModemEntry 3}
prtExPhPlModemStatus OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3),
relay (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether a Dial Up Modem is enabled on this port.
Default: disable
For Vmux devices this object shows whether there is Modem Relay support."
::= { prtExPhPlModemEntry 4}
prtExPhPlModemActivate OBJECT-TYPE
SYNTAX INTEGER
{
onFirstFrame(2),
always (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the Dial Up Modem is activated when
the first frame is received or it is always activated.
Default: onFirstFrame"
::= { prtExPhPlModemEntry 5}
prtExPhPlModemMaxIdleTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max Time allowed in Seconds without any traffic before the line
is disconnected.
Legal Values are: 1 sec, 2 sec .. 5 sec, 10 sec, 20 sec..
1 min, 2 min .. 10 min, 15 min, 20 min, 25 min, 30 min.
65535 sec. means that this parameter is not applicable.
Default: 1 sec."
::= { prtExPhPlModemEntry 6}
prtExPhPlModemTimeBtwnCalls OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum Time in Seconds which is required after a call was
disconnected. In this time no other call will be initiated
from this Modem port even if there were frames transmitted
to this port. This time is required for some Modems which
have initializations that take a few seconds.
Legal Values are:
0 sec. - 30 sec., 1-5 min.
65535 sec. means that this parameter is not applicable.
Default: 0 sec"
::= { prtExPhPlModemEntry 7}
prtExPhPlModemCallDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time in Seconds that the device will wait before dialing to the remote
device.
This feature is mostly used when there is a backup modem to the
main link and the main link is down. In this case it is important to prevent
the 2 devices from dialing through the backup modems to each other at the same time.
It is advised to configure one side with a small call delay and the other side
with a large call delay.
Legal Values are:
0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 .
65535 sec. means that this parameter is not applicable.
Default: 0 sec"
::= { prtExPhPlModemEntry 8}
--
-- Megaplex ?000/?004 LS-2 TDM I/O family card include:
-- Ls2-CCITT-X.50, Ls2-CCITT-X.58, Ls2-AT&T-SDM
--
--prtExLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 1}
--prtInLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 2}
prtExLs2CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExLs2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLs2Cnfg 1}
prtExLs2CnfgEntry OBJECT-TYPE
SYNTAX PrtExLs2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExLs2CnfgIdx, prtExLs2SltIdx, prtExLs2PrtIdx }
::= {prtExLs2CnfgTable 1}
PrtExLs2CnfgEntry ::=
SEQUENCE {
prtExLs2CnfgIdx Integer32,
prtExLs2SltIdx INTEGER,
prtExLs2PrtIdx INTEGER,
prtExLs2Connect INTEGER,
prtExLs2Rate INTEGER,
prtExLs2ClkMode INTEGER,
prtExLs2Cts INTEGER,
prtExLs2Dcd INTEGER,
prtExLs2EnvIdx Integer32
}
prtExLs2CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExLs2CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExLs2SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtExLs2CnfgEntry 2}
prtExLs2PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port index.
For the Ls2/X.58 exPrt(7)..exPrt(10) are not valid."
::= {prtExLs2CnfgEntry 3}
prtExLs2Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExLs2CnfgEntry 4}
prtExLs2Rate OBJECT-TYPE
SYNTAX INTEGER
{
r2400bps (2),
r4800bps (3),
r9600bps (4),
r19200bps (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port rates."
::= {prtExLs2CnfgEntry 5}
prtExLs2ClkMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
ext-dce (2),
dte (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port operation clock mode."
::= {prtExLs2CnfgEntry 6}
prtExLs2Cts OBJECT-TYPE
SYNTAX INTEGER
{
on (2),
rts-min (3),
rts-max (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CTS."
::= {prtExLs2CnfgEntry 7}
prtExLs2Dcd OBJECT-TYPE
SYNTAX INTEGER
{
on (2),
card-sync (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DCD."
::= {prtExLs2CnfgEntry 8}
prtExLs2EnvIdx OBJECT-TYPE
SYNTAX Integer32 (0..24)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Envelope Index.
When prtInLs2EnvAssign=auto, the value is 0 (not applicable)."
::= {prtExLs2CnfgEntry 9}
-- Ls2 Internal composit channel parameters
--
prtInLs2CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInLs2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLs2Cnfg 2}
prtInLs2CnfgEntry OBJECT-TYPE
SYNTAX PrtInLs2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInLs2CnfgIdx, prtInLs2SltIdx, prtInLs2PrtIdx }
::= {prtInLs2CnfgTable 1}
PrtInLs2CnfgEntry ::=
SEQUENCE {
prtInLs2CnfgIdx Integer32,
prtInLs2SltIdx INTEGER,
prtInLs2PrtIdx INTEGER,
prtInLs2Connect INTEGER,
prtInLs2Group Integer32,
prtInLs2Member Integer32,
prtInLs2LinkTo INTEGER,
prtInLs2EnvAssign INTEGER
}
prtInLs2CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInLs2CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtInLs2SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtInLs2CnfgEntry 2}
prtInLs2PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101),
inPrt2 (102)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal port index."
::= {prtInLs2CnfgEntry 3}
prtInLs2Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered in
any of the mux algorithms. It also affects all the module
considerations because the module has only one Internal
interface which is the composite channel."
::= {prtInLs2CnfgEntry 4}
prtInLs2Group OBJECT-TYPE
SYNTAX Integer32 (1..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the group number of the port.
LS-2 internal ports with the same group number share the same Time slot of the main
link"
::= {prtInLs2CnfgEntry 5}
prtInLs2Member OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the group member id of the port.
This parameter is for the automatic envelope assignment
algorithm."
::= {prtInLs2CnfgEntry 6}
prtInLs2LinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the
LS2 card is mapped.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtInLs2CnfgEntry 7}
prtInLs2EnvAssign OBJECT-TYPE
SYNTAX INTEGER
{
auto (2),
manual (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Envelope assignment type."
::= {prtInLs2CnfgEntry 8}
--
-- Megaplex?000/?004 VC-2, VC-6, VC-2/R2, VC-Q TDM I/O family port.
-- (Vc2E&m,Vc2Fxs1Plar,Vc2Fxo1,Vc2Fxs2,Vc2Fxo2,Vc2Fxs3,Vc2Fxo3)
-- Vc6E&M, Vc6Fxo, Vc6Fxs, Vc6aE&M, Vc6aFxo, Vc6aFxs
-- Vc2/R2(Fxs)
-- VC-Q
-- VC-12, VC-12/6
-- VC-8, VC-16
prtVc2CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtVc2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"- For products supporting more than one configuration, the write operation
into the Table is valid only to the TmpCnfg entry.
- For products that do not support configurations, the write operation
into the Table will be to prtVc2CnfgIdx=1."
::= { cnfgPrtMux 5}
prtVc2CnfgEntry OBJECT-TYPE
SYNTAX PrtVc2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtVc2CnfgIdx, prtVc2SltIdx, prtVc2PrtIdx }
::= { prtVc2CnfgTable 1}
PrtVc2CnfgEntry ::=
SEQUENCE {
prtVc2CnfgIdx Integer32,
prtVc2SltIdx INTEGER,
prtVc2PrtIdx Integer32,
prtExVc2Connect INTEGER,
prtExVc2TransGain Integer32,
prtExVc2ReceiveGain Integer32,
prtExVc2Wire INTEGER,
prtExVc2CodingLaw INTEGER,
prtExVc2Sig INTEGER,
prtExVc2Oos INTEGER,
prtExVc2LinkTo INTEGER,
prtExVc2OperMode INTEGER,
prtExVc2SigProfile INTEGER,
prtExVc2CallEnable INTEGER,
prtExVc2R2Delay INTEGER,
prtExVc2CasStd INTEGER,
prtExVc2EchoCanceler INTEGER,
prtExVc2IfType INTEGER,
prtExVc2Encoding INTEGER,
prtExVc2TxBitCode OCTET STRING,
prtExVc2RxBitOutput OCTET STRING,
prtExVc2MeterRate INTEGER,
prtExVc2IfSignaling INTEGER,
prtExVc2SeizeAck INTEGER,
prtExVc2EandMType INTEGER,
prtExVc2RemType INTEGER,
prtExVc2ConvTime INTEGER,
prtExVc2SigFeedback INTEGER,
prtExVc2EchoCancelerModule INTEGER,
prtExVc2ReversePolarity INTEGER,
prtExVc2RingerFrequency INTEGER,
prtExVc2SigService INTEGER,
prtExVc2CallerIdEnable INTEGER,
prtExVc2CompressMethod INTEGER,
prtExVc2ObMode INTEGER,
prtExVc2VAD INTEGER,
prtExVc2NoiseLevelForVAD INTEGER,
prtExVc2WesternSigMode INTEGER,
prtExVc2BusProtectionPoint INTEGER, --not used
prtExVc2ImpedanceStandard INTEGER
}
prtVc2CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtVc2CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtVc2SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
For Stand Alone products like WR: notApplicable (255)"
::= {prtVc2CnfgEntry 2}
prtVc2PrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card.
For MP-2100/2200 card ports, Web Ranger and FCD-IP Voice ports
the values will be:
exPrt1 (1)
exPrt2 (2)
exPrt3 (3)
exPrt4 (4)
exPrt5 (5)
exPrt6 (6)
exPrt7 (7)
exPrt8 (8)
exPrt9 (9)
exPrt10 (10)
exPrt11 (11)
exPrt12 (12)
exPrt13 (13)
exPrt14 (14)
exPrt15 (15)
exPrt16 (16)
For LA-240:
The index for fixed voice ports will be -
exPrt6 (6)
exPrt7 (7)
exPrt8 (8)
exPrt9 (9)
The index for voice card ports will be -
Slot number * 100 + ch (for IO-1: 101..104, for IO-2: 201..204).
For other products' index see their specification."
::= {prtVc2CnfgEntry 3}
prtExVc2Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3),
v51 (4),
v52 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtVc2CnfgEntry 4}
prtExVc2TransGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit gain in dBm.
For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8
VC-4/Omni and VC-16 cards, the units will be 0.1dBm because
valid values can be in 0.5dBm steps."
::= {prtVc2CnfgEntry 5}
prtExVc2ReceiveGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive gain in dBm.
For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8
VC-4/Omni and VC-16 cards, the units will be 0.1dBm because
valid values can be in 0.5dBm steps."
::= {prtVc2CnfgEntry 6}
prtExVc2Wire OBJECT-TYPE
SYNTAX INTEGER
{
w2wire (1),
w4wire (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For some cards, this object is equal for all the ports in the specific
card because of HW limitations.
For FXO & FXS this parameter is not applicable."
::= {prtVc2CnfgEntry 7}
prtExVc2CodingLaw OBJECT-TYPE
SYNTAX INTEGER
{
aLAW (1),
uLAW (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Method/Law for decoding/encoding the voice
information.
aLaw(1) is the standard Law for E1 links.
uLaw(2) is the standard Law for T1 links.
This object is equal for all the ports in the specific module because
of HW limitations"
::= {prtVc2CnfgEntry 8}
prtExVc2Sig OBJECT-TYPE
SYNTAX INTEGER
{
noSignaling (1),
robbedBitMultiFrame (2),
chAssociatedE1 (3),
robbedBitFrame (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the method for decoding/encoding the signaling
information(on/off hook).
noSignaling (1) - not using signaling (only voice).
robbedBitMultiFrame(2) - is the standard method for T1 links and
proprietary method for E1 links.
chAssociatedE1 (3) - is valid only for E1 G.732S links.
robbedBitFrame (4) - is proprietary method implimenting 7 bit for
the voice and 1 bit dedicated for signaling.
For some cards, this object is equal for all the ports in the specific module
because of HW limitations."
::= {prtVc2CnfgEntry 9}
prtExVc2Oos OBJECT-TYPE
SYNTAX INTEGER
{
forcedIdle (1),
forcedBusy (2),
busyIdle (3),
idleBusy (4),
notApplicable (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is equal for all the ports in the specific card
because of HW limitations"
::= {prtVc2CnfgEntry 10}
prtExVc2LinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This attribute indicates the slot of the ML card to which
the VC card is mapped.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtVc2CnfgEntry 11}
prtExVc2OperMode OBJECT-TYPE
SYNTAX INTEGER
{
normal (2),
unidirectRx (3),
broadcast (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the operation mode of the port.
normal = bi-directional (Tx/Rx)
unidirectRx = unidirectional Rx.
broadcast = Tx upon request."
::= {prtVc2CnfgEntry 12}
prtExVc2SigProfile OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
manual (2),
p1 (3),
p2 (4),
p3Fxo3S3 (5),
reversePolarity (6), --3RP
meteringPulse (7), --3MP
p4 (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Signaling Profile of the port.
notApplicable - for VC-2 family and when
prtExVc2Sig=noSignaling(1)
p1 = profile 1
p2 = profile 2
p3 = profile 3
p4 = profile 4 "
::= {prtVc2CnfgEntry 13}
prtExVc2CallEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
incoming (2),
outgoing (3),
both (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Enabled Call direction.
notApplicable - for all cards except VC-2/R2.
both - incoming + outgoing."
::= {prtVc2CnfgEntry 14}
prtExVc2R2Delay OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
terrestrial (2),
satellite (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the R2 Delay.
notApplicable - for all cards except VC-2/R2."
::= {prtVc2CnfgEntry 15}
prtExVc2CasStd OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
r2Q422 (2),
specialA (3),
specialB (4),
specialC (5),
specialD (6),
specialE (7),
specialF (8),
specialG (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the CAS (Channel Associated Signaling)
Standard.
notApplicable - for all cards except VC-2/R2."
::= {prtVc2CnfgEntry 16}
prtExVc2EchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation.
notApplicable - for VC-2 and VC-6 cards."
::= {prtVc2CnfgEntry 17}
prtExVc2IfType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
w2Em (2),
w4Em (3),
fxo (4),
fxs (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interface Type."
::= {prtVc2CnfgEntry 18}
prtExVc2Encoding OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
pcm (2),
adpcm (3),
linear (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Voice Encoding Mode.
linear - is relevant only for the ports of VC-16A card."
::= {prtVc2CnfgEntry 19}
prtExVc2TxBitCode OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
- - - For MP & FCD - - -
This object represents 4 parameters, by 2 Octets :
Tx D Bit Code-MSB nibble,
Tx C Bit Code- nibble,
Tx B Bit Code- nibble,
Tx A Bit Code-LSB nibble.
Each nibble:
0 hex = 0000 = Not Applicable
1 hex = 0001 = M lead
2 hex = 0010 = M lead inverse
3 hex = 0011 = Reverse Polarity
4 hex = 0100 = Metering Pulse
5 hex = 0101 = Forced 1
6 hex = 0110 = Forced 0
7-F hex - not used (invalid values)
This object will be RO if prtExVc2SigProfile is NOT manual.
- - - For WR II - - -
This object represents the following 4 parameters by 2 Octets:
1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1).
2. Default signaling bits that are not in use (nibble 2).
3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3).
4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4).
Each nibble:
---------------------------------------------------------------------------------------
Value On/Off Hook Default sig. Ring Detect. M (Mouth)
---------------------------------------------------------------------------------------
0 hex = 0000 Not Applicable Not Applicable. Not Applicable Not Applicable
1 hex = 0001 Tx A bit Values 1-3 are Tx A bit Tx A bit
2 hex = 0010 Tx A bit inverse for On/Off Hook Tx A bit inv. Tx A bit inv.
3 hex = 0011 Tx B bit A,B,A Inv,B Inv. Tx B bit Tx B bit
4 hex = 0100 Tx B bit inverse Values 4-7 are Tx B bit inv. Tx B bit inv.
5 hex = 0101 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid
6 hex = 0110 not Used-invalid A, A Inverse. not Used-invalid not Used-invalid
7 hex = 0111 not Used-invalid not Used-invalid not Used-invalid
8 hex = 1000 not Used-invalid Values 8-11 are not Used-invalid not Used-invalid
9 hex = 1001 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid
A hex = 1010 not used-invalid B, B Inverse. not Used-invalid not Used-invalid
B hex = 1011 not used-invalid The Bits order: not Used-invalid not Used-invalid
C-F hex not used-invalid ABCD not Used-invalid not Used-invalid
Default value: 11 11 "
::= {prtVc2CnfgEntry 20}
prtExVc2RxBitOutput OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
- - - For MP (VC-Q card only) & FCD - - -
This object represents 3 parameters by 2 Octets:
Spare -MSB nibble, always=0 hex
E Lead Output - nibble,
Reverse Polarity Output- nibble,
Metering Pulse Output -LSB nibble.
Each nibble:
0 hex = 0000 = Not Applicable
1 hex = 0001 = Rx A bit
2 hex = 0010 = Rx A bit inverse
3 hex = 0011 = Rx B bit
4 hex = 0100 = Rx B bit inverse
5 hex = 0101 = Rx C bit
6 hex = 0110 = Rx C bit inverse
7 hex = 0111 = Rx D bit
8 hex = 1000 = Rx D bit inverse
9 hex = 1001 = none
A-F hex - not used (invalid values)
This object will be RO if prtExVc2SigProfile is NOT manual.
- - - For MP (VC-8, VC-16, VC-16A cards) - - -
This object represents 4 parameters, by 2 Octets :
Tx D Bit Code-MSB nibble,
Tx C Bit Code- nibble,
Tx B Bit Code- nibble,
Tx A Bit Code-LSB nibble.
Each nibble:
0 hex = 0000 = Not Applicable
1 hex = 0001 = not used (invalid value)
2 hex = 0010 = not used (invalid value)
3 hex = 0011 = not used (invalid value)
4 hex = 0100 = not used (invalid value)
5 hex = 0101 = Forced 1
6 hex = 0110 = Forced 0
7-F hex - not used (invalid values)
This object will be RO.
- - - For WR II - - -
This object represents the following 2 parameters in 1 Octet:
1. On/Off hook signaling receive mode from the T1/E1 into the FXS/FXO (MSB nibble 1).
2. E (Ear) Signaling receive mode from the T1/E1 into the E&M (LSB nibble 2).
Each nibble:
---------------------------------------------------------------------------------------
Value On/Off Hook E (Ear)
---------------------------------------------------------------------------------------
0 hex = 0000 Not Applicable Not Applicable
1 hex = 0001 Rx A bit Rx A bit
2 hex = 0010 Rx A bit inverse Rx A bit inverse
3 hex = 0011 Rx B bit Rx B bit
4 hex = 0100 Rx B bit inverse Rx B bit inverse
5-F hex not used-invalid not Used-invalid
Default value: 11 "
::= {prtVc2CnfgEntry 21}
prtExVc2MeterRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
r16Khz (2),
r12Khz (3),
disabled(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is applicable only for VC-6A/FXO, VC-6A/FXS, VC-8/FXO,
VC-8/FXS, VC-16/FXO and VC-16/FXS.
Meter Rate means rate of Call Meter in Public Phones, in KHz units.
For some cards, the value must be the same for all card's ports."
::= {prtVc2CnfgEntry 22}
prtExVc2IfSignaling OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
loopStart (2),
groundStart (3),
winkStart (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is applicable only for VC-6A, VC-6AG, VC-8/FXO, VC-8/FXS,
VC-16/FXO and VC-16/FXS cards.
Interface Analog Signaling.
Must be the same for all card's ports.
loopStart - for the usual trunk/phone types.
groundStart - for trunks that need Ground signaling .
winkStart - for trunks that need Reverse Polarity. "
::= {prtVc2CnfgEntry 23}
prtExVc2SeizeAck OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter shows whether the device will acknowledge
a seize signal (On/Off Hook).
When the value is set to yes(3) & the device receives an on/off hook signal
it will transmit back an on/off hook signal.
When the value is set to no(2) & the device receives an on/off hook signal
it will NOT transmit back an on/off hook signal.
Default value for WR FXO: no(2)."
::= {prtVc2CnfgEntry 24}
prtExVc2EandMType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
type1 (2),
type2 (3),
type3 (4),
type5 (5) -- SSDC5
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the signaling type on the E&M analog side.
The analog signaling includes voltage, no. of pins and other parameters."
::= {prtVc2CnfgEntry 25}
prtExVc2RemType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
lb (2),
pbx (3),
e1 (4),
t1 (5), --T1ESF
t1D4 (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Remote Type.
Applicable for VC-6A/4LB card &
for IPMUX-1E Far End Type - E1,T1(T1-ESF) or T1-D4 ."
::= {prtVc2CnfgEntry 26}
prtExVc2ConvTime OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
m2 (2),
m3 (3),
m5 (4),
unlimited (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Conversation Time in minutes.
Applicable for VC-6A/4LB card."
::= {prtVc2CnfgEntry 27}
prtExVc2SigFeedback OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signaling Feedback.
Applicable for VC-8/FXO and VC-16/FXO cards."
::= {prtVc2CnfgEntry 28}
prtExVc2EchoCancelerModule OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
notExist (2),
exist (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates whether Echo canceler module exists for this port."
::= {prtVc2CnfgEntry 29}
prtExVc2ReversePolarity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object Enables/Disables Reverse Polarity for this port."
::= {prtVc2CnfgEntry 30}
prtExVc2RingerFrequency OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
f20Hz (2),
f25Hz (3),
f50Hz (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object selects the Ringer Frequency (Hz) for this port."
::= {prtVc2CnfgEntry 31}
prtExVc2SigService OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
advanced (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Signaling Service.
advanced - is relevant only for ports of VC-8, VC-16 FXS cards.
It is used for Signaling Services of V5.1 or R2."
::= {prtVc2CnfgEntry 32}
prtExVc2CallerIdEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object Enables/Disables Receiving the Caller Id number from the
remote side, for this port/channel."
::= {prtVc2CnfgEntry 33}
prtExVc2CompressMethod OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
g726 (2),
g727 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only when prtExVc2Encoding=adpcm.
It defines which method is used for Compression.
g726 - for 4 bits (the standard method).
g726 - for 3 bits. It is especially needed for T1 applications with signaling."
::= {prtVc2CnfgEntry 34}
prtExVc2ObMode OBJECT-TYPE
SYNTAX INTEGER
{
pointToPoint (1),
omniBus (2),
pointToMultiPointSrc(3),
pointToMultiPointDst(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Net operation mode of the Omni-Bus card's port.
pointToPoint - only 2 end-point ports talk; like any other voice card
omniBus - many talk and listen. Like conference call.
All can listen to all.
pointToMultiPointSrc - There is one Master who can be heard by all.
All can talk, but only the Master can hear all. Others can hear
only the Master. This port is of the Master (Src).
pointToMultiPointDst - There is one Master who can be heard by all.
All can talk, but only the Master can hear all. Others can hear
only the Master. This port is of a Destination (NOT Master)."
::= {prtVc2CnfgEntry 35}
prtExVc2VAD OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines whether Voice Activation Detector (VAD)
will be On or Off.
off - will be usually selected when a Modem is connected
to the port; not a phone.
notApplicable - when prtExVc2DspMode=pointToPoint."
::= {prtVc2CnfgEntry 36}
prtExVc2NoiseLevelForVAD OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
low (2),
medium (3),
high (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Level of Noise on the line,
the Voice Activation Detector (VAD) will have to deal with.
notApplicable - when prtExVc2VAD=off."
::= {prtVc2CnfgEntry 37}
prtExVc2WesternSigMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
detector (2),
generator (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Western Signaling Mode.
detector - detects signal and passes it as is.
generator - generates the signal.
notApplicable - when Western HW is not installed."
::= {prtVc2CnfgEntry 38}
prtExVc2BusProtectionPoint OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
no (2),
first (3),
last (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines if the port is Bus Protection Point or not.
notApplicable - when prtExVc2DspMode=pointToPoint.
When we have a chain of devices where the edge devices ports are the
Bus Protection Point, user must configure one of these ports as 'first'
and the other as 'last'. It does not matter which one, it just matters
that they will be different."
::= {prtVc2CnfgEntry 39}
prtExVc2ImpedanceStandard OBJECT-TYPE
SYNTAX INTEGER
{
g712 (1),
q552ETSI (2),
q522Italy(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Standard used for Impedance.
-G.712 - 600 Ohm - used in USA and other countries.
-Q552/ETSI - used in some countries in Europe
-Q522/Italy - used in Italy."
::= {prtVc2CnfgEntry 40}
--
-- Megaplex?000/?004 port specific config for HS(TDM) modules
-- HS-2,HS-3,HS-Q, HS-Q/SC, HS-6, HS-12
--
prtHsfCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtHsfCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { cnfgPrtMux 6}
prtHsfCnfgEntry OBJECT-TYPE
SYNTAX PrtHsfCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtHsfCnfgIdx, prtHsfSltIdx, prtHsfPrtIdx }
::= { prtHsfCnfgTable 1}
PrtHsfCnfgEntry ::=
SEQUENCE {
prtHsfCnfgIdx Integer32,
prtHsfSltIdx INTEGER,
prtHsfPrtIdx INTEGER,
prtExHsfConnect INTEGER,
prtExHsfRate INTEGER,
prtExHsfClkMode INTEGER,
prtExHsfCts INTEGER,
prtExHsfFifoSize INTEGER,
prtExHsfLinkTo INTEGER,
prtExHsfOperMode INTEGER,
prtExHsfInbandLoopback INTEGER,
prtExHsfClkPolarity INTEGER,
prtExHsfControlSignal INTEGER,
prtExHsfBcastRingSrcPort INTEGER
}
prtHsfCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relate to the TmpCnfg. "
::= {prtHsfCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtHsfSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtHsfCnfgEntry 2}
prtHsfPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
inPrt1 (101) ,
inPrt2 (102)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique external port index.
Hs2 has only two ports (exPrt1,exPrt2).
Hs3 has three ports (exPrt1,exPrt2,exPrt3).
Hsq and hsqN has four ports.
Hs6 has six external ports.
Hs12 has twelve external ports.
inPrt1, inPrt2 - are relevant for VID card."
::= {prtHsfCnfgEntry 3}
prtExHsfConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtHsfCnfgEntry 4}
prtExHsfRate OBJECT-TYPE
SYNTAX INTEGER
{
r1x56eq56Kbps (1),
r1x64eq64Kbps (2),
r2x56eq112Kbps (3),
r2x64eq128Kbps (4),
r3x56eq168Kbps (5),
r3x64eq192Kbps (6),
r4x56eq224Kbps (7),
r4x64eq256Kbps (8),
r5x56eq280Kbps (9),
r5x64eq320Kbps (10),
r6x56eq336Kbps (11),
r6x64eq384Kbps (12),
r7x56eq392Kbps (13),
r7x64eq448Kbps (14),
r8x56eq448Kbps (15),
r8x64eq512Kbps (16),
r9x56eq504Kbps (17),
r9x64eq576Kbps (18),
r10x56eq560Kbps (19),
r10x64eq640Kbps (20),
r11x56eq616Kbps (21),
r11x64eq704Kbps (22),
r12x56eq672Kbps (23),
r12x64eq768Kbps (24),
r13x56eq728Kbps (25),
r13x64eq832Kbps (26),
r14x56eq784Kbps (27),
r14x64eq896Kbps (28),
r15x56eq840Kbps (29),
r15x64eq960Kbps (30),
r16x56eq896Kbps (31),
r16x64eq1024Kbps(32),
r17x56eq952Kbps (33),
r17x64eq1088Kbps(34),
r18x56eq1008Kbps(35),
r18x64eq1152Kbps(36),
r19x56eq1064Kbps(37),
r19x64eq1216Kbps(38),
r20x56eq1120Kbps(39),
r20x64eq1280Kbps(40),
r21x56eq1176Kbps(41),
r21x64eq1344Kbps(42),
r22x56eq1232Kbps(43),
r22x64eq1408Kbps(44),
r23x56eq1288Kbps(45),
r23x64eq1472Kbps(46),
r24x56eq1344Kbps(47),
r24x64eq1536Kbps(48),
r25x56eq1400Kbps(49),
r25x64eq1600Kbps(50),
r26x56eq1456Kbps(51),
r26x64eq1664Kbps(52),
r27x56eq1512Kbps(53),
r27x64eq1728Kbps(54),
r28x56eq1568Kbps(55),
r28x64eq1792Kbps(56),
r29x56eq1624Kbps(57),
r29x64eq1856Kbps(58),
r30x56eq1680Kbps(59),
r30x64eq1920Kbps(60),
r31x56eq1736Kbps(61),
r31x64eq1984Kbps(62),
r32Kbps (63)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed. "
::= {prtHsfCnfgEntry 5}
prtExHsfClkMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
ext-dce (2),
dte (3),
none (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port operation clock mode."
::= { prtHsfCnfgEntry 6}
prtExHsfCts OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2),
rts (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique CTS control line
operation mode."
::= {prtHsfCnfgEntry 7}
prtExHsfFifoSize OBJECT-TYPE
SYNTAX INTEGER
{
auto (2),
s16bits (3),
s30bits (4),
s52bits (5),
s72bits (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Size in bits."
::= {prtHsfCnfgEntry 8}
prtExHsfLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This attribute indicates a slot of Main Link module, that the
port is linked to. This object is the same for all the
ports in the specific card because of HW limitations.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtHsfCnfgEntry 9}
prtExHsfOperMode OBJECT-TYPE
SYNTAX INTEGER
{
normal (2),
unidirectRx (3),
broadcast (4),
bidirBcastRing (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the operation mode of the port.
normal = bi-directional (Tx/Rx)
unidirectRx = unidirectional Rx.
broadcast = Tx upon request.
bidirBcastRing = Bidirectional Broadcast Ring. When this value is selected,
AND RTS=On, the port opens its transmission channel."
::= {prtHsfCnfgEntry 10}
prtExHsfInbandLoopback OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
ft1Enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if Inband Loopback from the Network
should be enabled or disabled."
::= {prtHsfCnfgEntry 11}
prtExHsfClkPolarity OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
invert (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the clock polarity.
For FCD-M this object will be applicable only for the fixed HS port
(the fixed port on the device)."
::= {prtHsfCnfgEntry 12}
prtExHsfControlSignal OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
local (2),
endToEnd (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Control Signal according to G.797 ITU-T standard.
For FCD-M this object will be applicable for the fixed HS port
(the fixed port on the device) and HS-Q/N channels.
Local and End to End are applicable only when channel Interface type is RS-530,
else it will be Not Applicable."
::= {prtHsfCnfgEntry 13}
prtExHsfBcastRingSrcPort OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
none (100) ,
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only when prtExHsfOperMode=
bidirBcastRing. In this case, the values mean:
- none - this port will be connected to ML in TSA as usual.
- exPrt1.. exPrtX ; X=maximum ports of the card in focus :
it means that the same TS that is assigned in TSA to this port
is actually connected also to this port, for Broadcast Ring mode.
Therefore, this port should NOT be connected to ML in TSA."
::= {prtHsfCnfgEntry 14}
--
-- Megaplex?000/?004 Hs-4/1(HS4T1) HS-4/2(HS4E1) port configuration
--
--prtExHs4CnfgTable OBJECT IDENTIFIER ::= {prtHs4Cnfg 1}
--prtExHs4TsCnfgTable OBJECT IDENTIFIER ::= {prtHs4Cnfg 2}
prtExHs4CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExHs4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtHs4Cnfg 1}
prtExHs4CnfgEntry OBJECT-TYPE
SYNTAX PrtExHs4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExHs4CnfgIdx, prtExHs4SltIdx, prtExHs4PrtIdx }
::= { prtExHs4CnfgTable 1}
PrtExHs4CnfgEntry ::=
SEQUENCE {
prtExHs4CnfgIdx Integer32,
prtExHs4SltIdx INTEGER,
prtExHs4PrtIdx INTEGER,
prtExHs4Connect INTEGER,
prtExHs4LineType INTEGER,
prtExHs4LineCode INTEGER,
prtExHs4LineLen INTEGER,
prtExHs4RestoreT INTEGER,
prtExHs4OosSig INTEGER,
prtExHs4OosCode INTEGER,
prtExHs4IdleCode Integer32,
prtExHs4MfClkSrcSlt INTEGER,
prtExHs4MfClkSrcPrt INTEGER
}
prtExHs4CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExHs4CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExHs4SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted."
::= {prtExHs4CnfgEntry 2}
prtExHs4PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtExHs4CnfgEntry 3}
prtExHs4Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithm. It also affects
all the module considerations because the card has only
one external (physical) interface."
::= {prtExHs4CnfgEntry 4}
prtExHs4LineType OBJECT-TYPE
SYNTAX INTEGER
{
esfT1 (2), --> dsx1ESF
sfT1 (3), --> dsx1D4
g732nE1 (4), --> dsx1E1
g732nE1CRC (5), --> dsx1E1-CRC
g732sE1 (6), --> dsx1E1-MF
g732sE1CRC (7) --> dsx1E1-MF-CRC
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line type parameter for T1/E1
interface.
The user should select only the parameters relevant to the
specific card:
T1 line code parameters for the HS-4/1 and
E1 line code parameters for the HS-4/2.
This parameter has the same values as dsx1LineType in T1/E1
MIB (RFC-1406). The parameters in dsx1LineType are:
other (1)
dsx1ESF (2)
dsx1D4 (3)
dsx1E1 (4)
dsx1E1-CRC (5)
dsx1E1-MF (6)
dsx1E1-MF-CRC (7)"
::= {prtExHs4CnfgEntry 5}
prtExHs4LineCode OBJECT-TYPE
SYNTAX INTEGER
{
b7T1 (1), --> dsx1JBZS
b8zsT1 (2), --> dsx1B8ZS
hdb3E1 (4) --> dsx1HDB3
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line code parameter used for T1/E1
interface.
The user should select only the parameters relevant to the
specific card:
T1 line code parameters for the MPH.1/T1 and
E1 line code parameters for the MPH.1/E1.
This parameter has the same values as dsx1LineCoding in T1/E1
MIB (RFC-1406). The parameters in dsx1LineCoding are:
dsx1JBZS (1)
dsx1B8ZS (2)
dsx1HDB3 (3)
dsx1ZBTSI (4)
dsx1AMI (5)
other (6)"
::= {prtExHs4CnfgEntry 6}
prtExHs4LineLen OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
len0p133ft (2),
len134p266ft (3),
len267p399ft (4),
len400p533ft (5),
len534p655ft (6),
fcc68 (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is the line length parameter used only for
T1 interfaces.
len399p533ft=len-399-533ft "
::= {prtExHs4CnfgEntry 7}
prtExHs4RestoreT OBJECT-TYPE
SYNTAX INTEGER
{
restoreT1secFast (2),
restoreT10sec62411 (3),
ccittE1 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time passing from the disappearance of the loss of
synchronization condition (red alarm), to the restoration
of normal service."
::= {prtExHs4CnfgEntry 8}
prtExHs4OosSig OBJECT-TYPE
SYNTAX INTEGER
{
notsupported (2),
forcedIdle (3),
forcedBusy (4),
busyIdle (5),
idleBusy (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Out of Service signal type."
::= {prtExHs4CnfgEntry 9}
prtExHs4OosCode OBJECT-TYPE
SYNTAX INTEGER
{
notsupported (2),
oosCode00H (3),
oosCode1aH (4),
oosCode54H (5),
oosCode7eH (6),
oosCode7fH (7),
oosCode98H (8),
oosCode9eH (9),
oosCoded5H (10),
oosCodee4H (11),
oosCodeffH (12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OOS Code"
::= {prtExHs4CnfgEntry 10}
prtExHs4IdleCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Type value(00 - FF HEX), excluding 0H,8H,10H,12H,21H,24H,
42H,49H,84H,92H"
::= {prtExHs4CnfgEntry 11}
prtExHs4MfClkSrcSlt OBJECT-TYPE
SYNTAX INTEGER
{
local (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port Tx is multiframe
synchronized with Rx multiframe of another port and the slot position of that port.
This opration is required in order to bypass signaling of PCM
voice channels.
When its value is Local(2) there is no meaning to 'prtExHs4MfClkSrcPrt'
parameter.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= {prtExHs4CnfgEntry 12}
prtExHs4MfClkSrcPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
inPrt1 (101)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify a port position in the mux if the
MultiFrame clock source is valid (YES).
inPrt1 - for MTML-H/E1 cards."
::= {prtExHs4CnfgEntry 13}
--
-- Hs4 Time Slot Config Table
--
prtExHs4TsCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExHs4TsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtHs4Cnfg 2}
prtExHs4TsEntry OBJECT-TYPE
SYNTAX PrtExHs4TsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExHs4TsCnfgIdx, prtExHs4TsSltIdx, prtExHs4TsPrtIdx, prtExHs4TsIdx }
::= { prtExHs4TsCnfgTable 1}
PrtExHs4TsEntry ::=
SEQUENCE {
prtExHs4TsCnfgIdx Integer32,
prtExHs4TsSltIdx INTEGER,
prtExHs4TsPrtIdx INTEGER,
prtExHs4TsIdx Integer32,
prtExHs4TsIConSlot INTEGER,
prtExHs4TsIConPrt INTEGER,
prtExHs4TsIConTs Integer32
}
prtExHs4TsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExHs4TsEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExHs4TsSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtExHs4TsEntry 2}
prtExHs4TsPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
Hs4/T1 and Hs4/T1 cards have only one external interface."
::= { prtExHs4TsEntry 3}
prtExHs4TsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are:
1..24 for T1 Card and
1..31 for E1 interface.
In G732S-E1 lines, time slot 16 is not valid for data,
it is dedicated to multiframe synchronization bits
and voice signaling."
::= { prtExHs4TsEntry 4}
prtExHs4TsIConSlot OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
split (100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the specified time slot is
connected/routed internally in the Agent and to which card
it is connected.
In the ?004 Unit the entries io6(10)..io16) are not valid.
split - will be used when the Src TS is connected to more
than one slot OR more than one port (each needing
less than a whole TS)."
::= {prtExHs4TsEntry 5}
prtExHs4TsIConPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12) ,
noConnect (100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the internally (In Mux)
connected/routed port."
::= {prtExHs4TsEntry 6}
prtExHs4TsIConTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique time slot position.
The valid time slots are:
1..24 for T1 Module and
1..31 for E1 interface.
In G732S-E1 lines time slot 16 is not valid for data,
it is dedicated for multiframe synchronization bits
and voice signaling."
::= { prtExHs4TsEntry 7}
--
-- Megaplex?000/?004 and DXC Hs-U port configuration
--
--prtExHsiCnfgTable OBJECT IDENTIFIER ::= {prtHsiCnfg 1}
prtExHsiCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExHsiCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtHsiCnfg 1}
prtExHsiCnfgEntry OBJECT-TYPE
SYNTAX PrtExHsiCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExHsiCnfgIdx, prtExHsiSltIdx, prtExHsiPrtIdx }
::= { prtExHsiCnfgTable 1}
PrtExHsiCnfgEntry ::=
SEQUENCE {
prtExHsiCnfgIdx Integer32,
prtExHsiSltIdx INTEGER,
prtExHsiPrtIdx Integer32,
prtExHsiConnect INTEGER,
prtExHsiRate INTEGER,
prtExHsiLinkTo INTEGER,
prtExHsiInterface INTEGER,
prtExHsiActType INTEGER
}
prtExHsiCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExHsiCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExHsiSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted."
::= {prtExHsiCnfgEntry 2}
prtExHsiPrtIdx OBJECT-TYPE
SYNTAX Integer32
-- {
-- exPrt1 (1),
-- exPrt2 (2),
-- exPrt3 (3),
-- exPrt4 (4),
-- exPrt5 (5),
-- exPrt6 (6),
-- exPrt7 (7),
-- exPrt8 (8),
-- exPrt9 (9),
-- exPrt10 (10),
-- exPrt11 (11),
-- exPrt12 (12)
-- }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card.
For MP : 1..12
For DXC: 111 .. 2531. See DXC R6 spec for port index convention.
For FCD-A, 'S' Interface external ports: 131, 141, 151, 161."
::= {prtExHsiCnfgEntry 3}
prtExHsiConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3),
v51 (4),
v52 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered in
any of the mux algorithms.
v51 - this port is connected to a V5.1 interface. All rest of the
values will be 'notApplicable' in this case. V5 MIB will be
used instead.
v52 - this port is connected to a V5.2 interface. All rest of the
values will be 'notApplicable' in this case. V5 MIB will be
used instead."
::= {prtExHsiCnfgEntry 4}
prtExHsiRate OBJECT-TYPE
SYNTAX INTEGER
{
r600bps (2),
r1200bps (3),
r2400bps (4),
r4800bps (5),
r9600bps (6),
r19200bps (7),
r38400bps (8),
r48kbps (9),
r56kbps (10),
r64kbps (11),
r128kbps (12),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed."
::= {prtExHsiCnfgEntry 5}
prtExHsiLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the HS-? card
is mapped.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtExHsiCnfgEntry 6}
prtExHsiInterface OBJECT-TYPE
SYNTAX INTEGER
{
lt (1),
nt (2),
te (3),
lt1 (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It indicates the interface type:
lt = line termination
nt = network termination
te = terminal equipment.
lt1 - for ASMi-31 connection (not ISDN)
For MP:
For HS-U/I only 'lt' and 'nt' are applicable.
For HS-U/1 only 'lt' is applicable.
For HS-S , only 'te' and 'nt' are applicable.
For HS-U, this object is not applicable.
For HS-U6, HS-U12, are applicable: 'lt'=lt-i,'nt'=nt-i, lt1.
For DXC:
For HS-U8, HS-U16, are applicable: 'lt'=LT-I,'nt'=NT-I, 'lt1'=LT-1."
::= {prtExHsiCnfgEntry 7}
prtExHsiActType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
type1 (2),
type2 (3),
type3 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It indicates the Activation Type. Activation Type is the Synchronization
type towards the PBX. It is applicable only when prtExHsiInterface=nt.
notApplicable - for cards that do not support this object, or when
prtExHsiInterface is NOT nt."
::= {prtExHsiCnfgEntry 8}
--prtInHsiCnfgTable OBJECT IDENTIFIER ::= {prtHsiCnfg 2}
--This table is not applicable for MP-2100 HS-U card type
prtInHsiCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInHsiCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry.
This table is not applicable for MP-2100 HS-U card type."
::= {prtHsiCnfg 2}
prtInHsiCnfgEntry OBJECT-TYPE
SYNTAX PrtInHsiCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInHsiCnfgIdx, prtInHsiSltIdx, prtInHsiPrtIdx }
::= { prtInHsiCnfgTable 1}
PrtInHsiCnfgEntry ::=
SEQUENCE {
prtInHsiCnfgIdx Integer32,
prtInHsiSltIdx INTEGER,
prtInHsiPrtIdx Integer32,
prtInHsiConnect INTEGER,
prtInHsiRate INTEGER,
prtInHsiConcentratedTo Integer32
}
prtInHsiCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInHsiCnfgEntry 1}
prtInHsiSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique slot position where
the card is inserted."
::= {prtInHsiCnfgEntry 2}
prtInHsiPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card.
Valid values for MP: inPrt1 (101) .. inPrt48 (148).
Valid values for DXC: 11012.. 25316. See DXC R6 spec for port index convention."
::= {prtInHsiCnfgEntry 3}
prtInHsiConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered in
any of the mux algorithms."
::= {prtInHsiCnfgEntry 4}
prtInHsiRate OBJECT-TYPE
SYNTAX INTEGER
{
r600bps (2),
r1200bps (3),
r2400bps (4),
r4800bps (5),
r9600bps (6),
r19200bps (7),
r38400bps (8),
r48kbps (9),
r56kbps (10),
r64kbps (11),
r128kbps (12),
concentrated (13),
notConnected (100),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port speed.
For HS-U/I and HS-S ports:
2 bit - up to 9600bps
4 bit - 19200bps
8 bit - 38400bps .. 64kbps.
concentrated - this D channel goes to a Concentration channel,
that represents many channels that this value was
selected for them. The Concentrated channel is an
Internal D Channel of the same card.
This value is applicable only for D channels, except
Concentration channel itself.
--for HS-S and HS-U/I cards the Concentration channel
will always be: internal-13
--for MP-2200 HS-S12, HS-S6, HS-U12, HS-U6 and
DXC HS-U8 and HS-U16 cards, the Concentration channel
is selected via the prtInHsiConcentratedTo object.
notConnected - same as prtInHsiConnect=no."
::= {prtInHsiCnfgEntry 5}
prtInHsiConcentratedTo OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Concentration D Channel of the prtInHsiPrtIdx port.
The port always belongs to the same card as prtInHsiPrtIdx port.
This object is applicable only when prtInHsiRate=concentrated.
Valid values:
- notApplicable: 255
- for MP-2200: HS-S12, HS-U12 cards: inPrt37 (137) .. inPrt48 (148).
HS-S6, HS-U6 cards: inPrt19 (119) .. inPrt24 (124).
- for DXC: HS-U8 cards: 112 .. 254
HS-U16 cards: 112 .. 258. See DXC R6 spec for port index
convention."
::= {prtInHsiCnfgEntry 6}
--
-- Megaplex?000/?004 Hs-R and HS-U port configuration
-- DXC HS-U8, HS-U16 port configuration for Interface=LT-1
--
--prtExHsrCnfgTable OBJECT IDENTIFIER ::= {prtHsrCnfg 1}
prtExHsrCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExHsrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtHsrCnfg 1}
prtExHsrCnfgEntry OBJECT-TYPE
SYNTAX PrtExHsrCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExHsrCnfgIdx, prtExHsrSltIdx, prtExHsrPrtIdx }
::= { prtExHsrCnfgTable 1}
PrtExHsrCnfgEntry ::=
SEQUENCE {
prtExHsrCnfgIdx Integer32,
prtExHsrSltIdx INTEGER,
prtExHsrPrtIdx Integer32,
prtExHsrConnect INTEGER,
prtExHsrProtocol INTEGER,
prtExHsrRate INTEGER,
prtExHsrDataBits INTEGER,
prtExHsrParity INTEGER,
prtExHsrStopBits INTEGER,
prtExHsrCts INTEGER,
prtExHsrClkMode INTEGER,
prtExHsrLinkTo INTEGER,
prtExHsrDcdDsr INTEGER,
prtExHsrOperMode INTEGER,
prtExHsrRtsDtr INTEGER,
prtExHsrLlbEnable INTEGER,
prtExHsrRlbEnable INTEGER,
prtExHsrRateAdapt INTEGER,
prtExHsrRemoteModem INTEGER ,
prtExHsrEncapsMode INTEGER
}
prtExHsrCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExHsrCnfgEntry 1}
prtExHsrSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
io13 (17),
io14 (18),
io15 (19)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique slot position where
the card is inserted."
::= {prtExHsrCnfgEntry 2}
prtExHsrPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique prt identifier within the card.
Valid values:
For MP:
- For HS-R cards: exPrt1 (1) .. exPrt4 (4)
- For HS-U/1 cards: inPrt1 (101) .. inPrt4 (104)
- For HS-S12, HS-S6, HS-U12, HS-U6 cards:
exPrt1 (1) .. exPrt12 (12).
This MIB table is used only for LT-1 interface.
For DXC:
- For HS-U8, HS-U16 cards:
111 .. 2531 (See DXC R6 spec for port index convention).
This MIB table is used only for LT-1 interface."
::= {prtExHsrCnfgEntry 3}
prtExHsrConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port should be considered in
any of the mux algorithms."
::= {prtExHsrCnfgEntry 4}
prtExHsrProtocol OBJECT-TYPE
SYNTAX INTEGER
{
sync (2),
async (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the protocol."
::= {prtExHsrCnfgEntry 5}
prtExHsrRate OBJECT-TYPE
SYNTAX INTEGER
{
r600bps (2),
r1200bps (3),
r2400bps (4),
r4800bps (5),
r9600bps (6),
r19200bps (7),
r38400bps (8),
r48kbps (9),
r56kbps (10),
r64kbps (11),
r16000bps (12),
r32000bps (13),
r57600bps (14),
r115200bps(15),
r128000bps(16),
r7200bps (17),
r14400bps (18),
r28800bps (19),
notConnected (100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port speed.
The 16,32,48,56,64 and 128 kbps rates are applicable only for Sync
protocol.
The 57.6 and 115.2 kbps rates are applicable only for Async
protocol.
notConnected= 0 rate."
::= {prtExHsrCnfgEntry 6}
prtExHsrDataBits OBJECT-TYPE
SYNTAX INTEGER
{
d5bits (1),
d6bits (2),
d7bits (3),
d8bits (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data Bits.
This object is applicable for Async protocol only."
::= {prtExHsrCnfgEntry 7}
prtExHsrParity OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3),
odd (4),
even(5),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"- For HS-R card, this object indicates if the parity bit is needed or not.
Therefore, the 'no' and 'yes; values are applicable.
- For HS-S12, HS-U12, the parity type is selected: no, odd, even.
This object is applicable for Async protocol only."
::= { prtExHsrCnfgEntry 8}
prtExHsrStopBits OBJECT-TYPE
SYNTAX INTEGER
{
stopBits1Bit (1),
stopBits2Bits (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the minimum number of stop bits in
the tx async frame.
This object is applicable for Async protocol only."
::= { prtExHsrCnfgEntry 9}
prtExHsrCts OBJECT-TYPE
SYNTAX INTEGER
{
on (2),
rts (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CTS.
This object is applicable for Async protocol only."
::= {prtExHsrCnfgEntry 10}
prtExHsrClkMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
extDce (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock mode.
This object is applicable for Sync protocol only."
::= { prtExHsrCnfgEntry 11}
prtExHsrLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the HS-R card
is mapped.
notApplicable - for HS-U/1 internal ports.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtExHsrCnfgEntry 12}
prtExHsrDcdDsr OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
local (2),
endToEnd (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DCD & DSR."
::= {prtExHsrCnfgEntry 13}
prtExHsrOperMode OBJECT-TYPE
SYNTAX INTEGER
{
normal (2),
unidirectRx (3),
broadcast (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the operation mode of the port.
normal = bi-directional (Tx/Rx)
unidirectRx = unidirectional Rx.
broadcast = Tx upon request."
::= {prtExHsrCnfgEntry 14}
prtExHsrRtsDtr OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
local (2),
endToEnd (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"RTS & DTR."
::= {prtExHsrCnfgEntry 15}
prtExHsrLlbEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable LLB."
::= {prtExHsrCnfgEntry 16}
prtExHsrRlbEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RLB."
::= {prtExHsrCnfgEntry 17}
prtExHsrRateAdapt OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
proprietary (2),
v110 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate Adaptation - takes a low rate and adapts it to 64Kbps.
This object specifies the means this adaptation is done by."
::= {prtExHsrCnfgEntry 18}
prtExHsrRemoteModem OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
asmi31 (2),
asmi31s2 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Remote modem.
asmi31s2 = ASMi-31/2 "
::= {prtExHsrCnfgEntry 19}
prtExHsrEncapsMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
bwOptimized (2),
latencyOptimized (3),
asmi31 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Low Speed encapsulation method over PCM.
When Encapsulation mode is Latency optimized, only rates up to 19.2 are supported.
In this case a double number of bits occupy the Time Slot.
For up to 9.6 Kbps - 4 bits are occupied.
For 14.4 & 19.2 Kbps - 8 bits are occupied.
When Encapsulation Mode is Bandwidth Optimized:
For up to 9.6 Kbps - 2 bits are occupied.
For 14.4 & 19.2 Kbps - 4 bits are occupied.
For higher rates - 8 bits are occupied."
::= {prtExHsrCnfgEntry 20}
--
-- Megaplex?000/?004 MBE port configuration
--
prtExMbeCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExMbeCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtMbeCnfg 1}
prtExMbeCnfgEntry OBJECT-TYPE
SYNTAX PrtExMbeCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExMbeCnfgIdx, prtExMbeSltIdx, prtExMbePrtIdx }
::= { prtExMbeCnfgTable 1}
PrtExMbeCnfgEntry ::=
SEQUENCE {
prtExMbeCnfgIdx Integer32,
prtExMbeSltIdx INTEGER,
prtExMbePrtIdx INTEGER,
prtExMbeLan INTEGER
}
prtExMbeCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExMbeCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExMbeSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtExMbeCnfgEntry 2}
prtExMbePrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card."
::= {prtExMbeCnfgEntry 3}
prtExMbeLan OBJECT-TYPE
SYNTAX INTEGER
{
remote (1),
main (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the MBE port is operated
as main or remote bridge."
::= {prtExMbeCnfgEntry 4}
prtInMbeCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInMbeCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtMbeCnfg 2}
prtInMbeCnfgEntry OBJECT-TYPE
SYNTAX PrtInMbeCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInMbeCnfgIdx, prtInMbeSltIdx, prtInMbePrtIdx }
::= { prtInMbeCnfgTable 1}
PrtInMbeCnfgEntry ::=
SEQUENCE {
prtInMbeCnfgIdx Integer32,
prtInMbeSltIdx INTEGER,
prtInMbePrtIdx INTEGER,
prtInMbeConnect INTEGER,
prtInMbeRate INTEGER,
prtInMbeLinkTo INTEGER
}
prtInMbeCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInMbeCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtInMbeSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtInMbeCnfgEntry 2}
prtInMbePrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card."
::= {prtInMbeCnfgEntry 3}
prtInMbeConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered in
any of the mux algorithms."
::= {prtInMbeCnfgEntry 4}
prtInMbeRate OBJECT-TYPE
SYNTAX INTEGER
{
r1x64eq64Kbps (1),
r2x64eq128Kbps (2),
r3x64eq192Kbps (3),
r4x64eq256Kbps (4),
r5x64eq320Kbps (5),
r6x64eq384Kbps (6),
r7x64eq448Kbps (7),
r8x64eq512Kbps (8),
r9x64eq576Kbps (9),
r10x64eq640Kbps (10),
r11x64eq704Kbps (11),
r12x64eq768Kbps (12),
r13x64eq832Kbps (13),
r14x64eq896Kbps (14),
r15x64eq960Kbps (15),
r16x64eq1024Kbps(16),
r17x64eq1088Kbps(17),
r18x64eq1152Kbps(18),
r19x64eq1216Kbps(19),
r20x64eq1280Kbps(20),
r21x64eq1344Kbps(21),
r22x64eq1408Kbps(22),
r23x64eq1472Kbps(23),
r24x64eq1536Kbps(24)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed."
::= {prtInMbeCnfgEntry 5}
prtInMbeLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the
MBE card is mapped.
In the ?004 Unit the entries io6(10)..io16) are not valid.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtInMbeCnfgEntry 6}
--
-- Megaplex?000/?004 TRE port configuration
--
prtExTreCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExTreCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtTreCnfg 1}
prtExTreCnfgEntry OBJECT-TYPE
SYNTAX PrtExTreCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExTreCnfgIdx, prtExTreSltIdx, prtExTrePrtIdx }
::= { prtExTreCnfgTable 1}
PrtExTreCnfgEntry ::=
SEQUENCE {
prtExTreCnfgIdx Integer32,
prtExTreSltIdx INTEGER,
prtExTrePrtIdx INTEGER,
prtExTreLan INTEGER,
prtExTreLanRate INTEGER
}
prtExTreCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExTreCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExTreSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtExTreCnfgEntry 2}
prtExTrePrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card."
::= {prtExTreCnfgEntry 3}
prtExTreLan OBJECT-TYPE
SYNTAX INTEGER
{
remote (1),
main (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the TRE port is operated
as main or remote bridge.
Default=remote."
::= {prtExTreCnfgEntry 4}
prtExTreLanRate OBJECT-TYPE
SYNTAX INTEGER
{
r4M (1),
r16M (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Rate of the TRE port
in Mbit/sec.
Default-r4M."
::= {prtExTreCnfgEntry 5}
prtInTreCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInTreCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtTreCnfg 2}
prtInTreCnfgEntry OBJECT-TYPE
SYNTAX PrtInTreCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInTreCnfgIdx, prtInTreSltIdx, prtInTrePrtIdx }
::= { prtInTreCnfgTable 1}
PrtInTreCnfgEntry ::=
SEQUENCE {
prtInTreCnfgIdx Integer32,
prtInTreSltIdx INTEGER,
prtInTrePrtIdx INTEGER,
prtInTreConnect INTEGER,
prtInTreRate INTEGER,
prtInTreLinkTo INTEGER
}
prtInTreCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInTreCnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtInTreSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid."
::= {prtInTreCnfgEntry 2}
prtInTrePrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique port identifier within the card."
::= {prtInTreCnfgEntry 3}
prtInTreConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered
in any of the mux algorithms."
::= {prtInTreCnfgEntry 4}
prtInTreRate OBJECT-TYPE
SYNTAX INTEGER
{
r1x56eq56Kbps (1),
r1x64eq64Kbps (2),
r2x56eq112Kbps (3),
r2x64eq128Kbps (4),
r3x56eq168Kbps (5),
r3x64eq192Kbps (6),
r4x56eq224Kbps (7),
r4x64eq256Kbps (8),
r5x56eq280Kbps (9),
r5x64eq320Kbps (10),
r6x56eq336Kbps (11),
r6x64eq384Kbps (12),
r7x56eq392Kbps (13),
r7x64eq448Kbps (14),
r8x56eq448Kbps (15),
r8x64eq512Kbps (16),
r9x56eq504Kbps (17)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port speed."
::= {prtInTreCnfgEntry 5}
prtInTreLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the
MBE card is mapped.
In the ?004 Unit the entries io6(10)..io16) are not valid.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtInTreCnfgEntry 6}
-- Packet VC cards.
-- This table is used for compressed voice cards with 4/8 ports.
--
prtExPVc4CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPVc4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtPVc4Cnfg 1}
prtExPVc4CnfgEntry OBJECT-TYPE
SYNTAX PrtExPVc4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPVc4CnfgIdx, prtExPVc4SltIdx, prtExPVc4PrtIdx }
::= { prtExPVc4CnfgTable 1}
PrtExPVc4CnfgEntry ::=
SEQUENCE {
prtExPVc4CnfgIdx Integer32,
prtExPVc4SltIdx INTEGER,
prtExPVc4PrtIdx INTEGER,
prtExPVc4PrtType INTEGER,
prtExPVc4Connect INTEGER,
prtExPVc4IfType INTEGER,
prtExPVc4TxGain Integer32,
prtExPVc4RxGain Integer32,
prtExPVc4MaxRate INTEGER,
prtExPVc4Tc INTEGER,
prtExPVc4Oos INTEGER,
prtExPVc4EchoCanceler INTEGER,
prtExPVc4VarDelay Integer32,
prtExPVc4CongLevel Integer32,
prtExPVc4Wire INTEGER,
prtExPVc4ExtensionType INTEGER,
prtExPVc4ExtensionNumber DisplayString,
prtExPVc4OutPulsing INTEGER,
prtExPVc4HuntGroupMb INTEGER,
prtExPVc4HuntGroupIdx Integer32,
prtExPVc4AutoFaxMode INTEGER,
prtExPVc4FaxRate INTEGER,
prtExPVc4SeizeAck INTEGER,
prtExPVc4SignalingProtocol INTEGER,
prtExPVc4DelayStart Integer32,
prtExPVc4WinkMinDuration Integer32,
prtExPVc4WinkMaxDuration Integer32,
prtExPVc4GenerateTone INTEGER,
prtExPVc4CodingLaw INTEGER,
prtExPVc4GenerateRingBack INTEGER,
prtExPVc4ChannelId Integer32,
prtExPVc4PortConnection INTEGER,
prtExPVc4CoderAndRate INTEGER,
prtExPVc4DestinationNum DisplayString,
prtExPVc4DtmfRelay INTEGER,
prtExPVc4DiscOnSilence Integer32,
prtExPVc4DynamicJitter INTEGER,
prtExPVc4EandMType INTEGER,
prtExPVc4Rate Integer32,
prtExPVc4FrameSize Integer32,
prtExPVc4MultiplexInterval Integer32,
prtExPVc4TransportProtocol INTEGER,
prtExPVc4MultiFreqRelay INTEGER,
prtExPVc4MinPulseWidth Integer32,
prtExPVc4MinPowerLevel Integer32,
prtExPVc4SuperTandem INTEGER,
prtExPVc4DestIp IpAddress,
prtExPVc4DestBundle Integer32,
prtExPVc4SrcIpAddress IpAddress,
prtExPVc4SrcIpMask IpAddress,
prtExPVc4DefaultGateway IpAddress,
prtExPVc4SigPacketInterval Unsigned32
}
prtExPVc4CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExPVc4CnfgEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPVc4SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted."
::= {prtExPVc4CnfgEntry 2}
prtExPVc4PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
inPrt1(101),
inPrt2(102),
inPrt3(103),
inPrt4(104),
inPrt5(105),
inPrt6(106),
inPrt7(107),
inPrt8(108)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the port number in the selected card
(slot)."
::= {prtExPVc4CnfgEntry 3}
prtExPVc4PrtType OBJECT-TYPE
SYNTAX INTEGER
{
eAndM (1),
fxo (2),
fxs (3),
internal(4),
s0 (5),
u (6),
sQsig (7),
uQsig (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the type of the selected port.
In Mx 30/300 phase 4: s0 & u are for Voice over ISDN.
In MX 30/300 phase 5: sQsig & uQsig are used for Voice over ISDN with Qsig option.
In MX MVC4 voice cards, each pair of ports 1-2, 3-4 may have a different type:
E&M, FXO, FXS.
In MVC4 compressed voice cards ports 1..4 have the same interface for all ports.
In MVC8 compressed voice cards each group of ports 1..4, 5..8 may have
a different type: E&M, FXO, FXS."
::= {prtExPVc4CnfgEntry 4}
prtExPVc4Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExPVc4CnfgEntry 5}
prtExPVc4IfType OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
eAndM4wires (2),
eAndM2wires (3),
fxoGnd (4),
fxoLoop (5),
fxsGnd (6),
fxsLoop (7),
e1Framer (8),
e1Slave (9),
t1Framer (10),
t1Slave (11)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the interface type of the port.
eAndM4wires and eAndM2wires - are valid only for E&M
port type
eAndM4wires - means 2/4 wires
fxoGnd and fxoLoop - are valid only for FXO port type
fxsGnd and fxsLoop - are valid only for FXS port type
e1Framer, e1Slave, t1Framer, t1Slave - are applicable for the mvc4Pbx
cards only."
::= {prtExPVc4CnfgEntry 6}
prtExPVc4TxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmission gain in dB."
::= {prtExPVc4CnfgEntry 7}
prtExPVc4RxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reception gain in dBm."
::= {prtExPVc4CnfgEntry 8}
prtExPVc4MaxRate OBJECT-TYPE
SYNTAX INTEGER
{
notConnected (1),
r4800bps (2),
r7200bps (3),
r9600bps (4),
notApplicatble (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Voice rate."
::= {prtExPVc4CnfgEntry 9}
prtExPVc4Tc OBJECT-TYPE
SYNTAX INTEGER
{
t1sec (1),
t2sec (2),
t3sec (3),
t4sec (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time interval for CIR control, in seconds. The value will
be the same for all cards' ports."
::= {prtExPVc4CnfgEntry 10}
prtExPVc4Oos OBJECT-TYPE
SYNTAX INTEGER
{
notSupported (2),
forcedIdle (3),
forcedBusy (4),
busyIdle (5),
idleBusy (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Handling type, when connection is lost."
::= {prtExPVc4CnfgEntry 11}
prtExPVc4EchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation."
::= {prtExPVc4CnfgEntry 12}
prtExPVc4VarDelay OBJECT-TYPE
SYNTAX Integer32 (0..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum variant delay of the FR network, in msec."
::= {prtExPVc4CnfgEntry 13}
prtExPVc4CongLevel OBJECT-TYPE
SYNTAX Integer32 (0..70)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the level of delayed data in
precents of total available dynamic memory,
for which the port will start to operate as congested.
The resolution of the parameter is 5%."
::= {prtExPVc4CnfgEntry 14}
prtExPVc4Wire OBJECT-TYPE
SYNTAX INTEGER
{
w2wire (1),
w4wire (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the wiring of the E&M port.
It is applicable only for E&M card type."
::= {prtExPVc4CnfgEntry 15}
prtExPVc4ExtensionType OBJECT-TYPE
SYNTAX INTEGER
{ notApplicable(1),
forceConnect(2),
voiceSwitching(3),
transparent(4),
transparentPlus(5),
ipForceConnect(6),
permanentDial (7),
autoAccept (8) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the type of extension relevant for this port.
ipForceConnect (6) is used for automatic connection or automatic
dialing when the phone is off hook (hot line).
permanentDial (7) means that the call is established upon power up.
The hook may be on or off.
Permanent Dialing can be used when there is no signaling.
autoAccept (8) means that the called party in the Permanent Dialing
will accept the call from the remote side automatically
upon on or off hook."
::= {prtExPVc4CnfgEntry 16}
prtExPVc4ExtensionNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the extension number of this port.
This field is relevant only when the extension
type is voice switching and is read only if the
port is member of a hunt group."
::= {prtExPVc4CnfgEntry 17}
prtExPVc4OutPulsing OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1), no(2), yes(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field indicates whether to outpulse the received
digits. It is notApplicable(1) when the extension type
is forceConnect(2)."
::= {prtExPVc4CnfgEntry 18}
prtExPVc4HuntGroupMb OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1), no(2), yes(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if this port belongs to
an hunt group."
::= {prtExPVc4CnfgEntry 19}
prtExPVc4HuntGroupIdx OBJECT-TYPE
SYNTAX Integer32(0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If it belongs to an hunt group, this fields
indicates the index of the relevant hunt group.
0 = notApplicable "
::= {prtExPVc4CnfgEntry 20}
prtExPVc4AutoFaxMode OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1), no(2), yes(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates if the system will switch automatically to
FAX mode when detecting FAX activity.
Default=Yes."
::= {prtExPVc4CnfgEntry 21}
prtExPVc4FaxRate OBJECT-TYPE
SYNTAX INTEGER
{
notConnected (1),
r4800bps (2),
r7200bps (3),
r9600bps (4),
r12000bps (5),
r14400bps (6),
r2400bps (7),
vbdFax (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"FAX initial rate.
Default=9600 bps."
::= {prtExPVc4CnfgEntry 22}
prtExPVc4SeizeAck OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter shows whether the device will acknowledge
a seize signal (On/Off Hook).
When the value is set to yes(3) & the device receives an on/off hook signal
it will transmit back an on/off hook signal.
When the value is set to no(2) & the device receives an on/off hook signal
it will NOT transmit back an on/off hook signal.
Example:
If Seize Ack Parameter = YES, when the MVC.4 receives a seize signal (Off Hook)
from the PBX it will send an Off Hook to the PBX.
The Seize Parameter is relevant for all the following cards:
MVC-4
MVC-4/E1-Framer
MVC-4/T1-DSU-Framer
MVC-4/T1-CSU-Framer
MVC-4/E1-SLAVE
MVC-4/T1-SLAVE
Default values:
Analog FXS - No (value can't be changed).
Analog FXO - Yes (value can't be changed).
Analog E&M - No (values NO/YES).
Digital E1/T1 Framer & Slave - No."
::= {prtExPVc4CnfgEntry 23}
prtExPVc4SignalingProtocol OBJECT-TYPE
SYNTAX INTEGER
{
delayStart (2),
immediateStart (3),
winkStart (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The signaling protocol that will be used between the PABX & the voice port.
Delay Start Protocol: the line is seized by sending an Off hook signal
and after a delay, if the called party is available (On hook)
DTMF (Dual Tone Multi Frequency) digits are sent towards the called party.
Immediate Start Protocol: the line is seized by sending an Off Hook signal
and immediately DTMF digits are sent towards the called party.
Wink start protocol: the line is seized by sending an Off Hook signal
and then the called party sends a short Off Hook wink signal.
Now the calling party starts sending DTMF digits."
::= {prtExPVc4CnfgEntry 24}
prtExPVc4DelayStart OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used only for Delay Protocol.
This is the time that the calling party will wait after sending an Off hook
signal and before sending DTMF digits to the called party.
The delay values are 100..5000 msec in intervals of 100 msec."
::= {prtExPVc4CnfgEntry 25}
prtExPVc4WinkMinDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used only for Wink Protocol.
Min Duration of the Wink Signal (off hook duration from the called party).
Legal values: 40..400 msec in intervals of 10 msec."
::= {prtExPVc4CnfgEntry 26}
prtExPVc4WinkMaxDuration OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used only for Wink Protocol.
Max Duration of the Wink Signal (off hook duration from the called party).
Legal values: 40..400 msec in intervals of 10 msec."
::= {prtExPVc4CnfgEntry 27}
prtExPVc4GenerateTone OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates whether the device (MX or MPH) should generate
dial tones for the channel.
If the value is yes (3), it generates dial tones.
If the value is no (2), the connected equipment will generate dial tones.
For example for some ISDN sets the dial tone is generated by the
phone itself while for others sets it is generated by the MX."
::= {prtExPVc4CnfgEntry 28}
prtExPVc4CodingLaw OBJECT-TYPE
SYNTAX INTEGER
{
aLAW (1),
uLAW (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Method/Law for decoding/encoding the voice
information.
aLaw(1) is the standard Law for E1 links.
uLaw(2) is the standard Law for T1 links.
This object is equal for all the ports in the specific module because
of HW limitations"
::= {prtExPVc4CnfgEntry 29}
prtExPVc4GenerateRingBack OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines whether the Ring Back tone is generated locally or from the
remote end.
The default is - NO (Meaning coming from the remote end).
Yes means that the Ring Back Tone is generated locally.
Applicable only for Force Connect."
::= {prtExPVc4CnfgEntry 30}
prtExPVc4ChannelId OBJECT-TYPE
SYNTAX Integer32 (0..256)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Channel Identifier.
According to FRF11 each voice port that works as force connect should add a
CH Id after the DLCI in the frame header.
Default : 1
Applicable only for Force Connect.
Not Applicable value will be 0."
::= {prtExPVc4CnfgEntry 31}
prtExPVc4PortConnection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
line (2),
trunk (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port connection determines whether the port is connected to a PABX (Trunk) or to
Telephone set (Line) .
It determines whether to send certain messages to the port or not.
If the type is LINE then the port generates a
ring back tone , if TRUNK it doesn't (The PBX does it)."
::= {prtExPVc4CnfgEntry 32}
prtExPVc4CoderAndRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
g7231r6300BPS (2),
g7231r5300BPS (3),
g729A8KBPS (4),
g711aLAW (5),
g711uLAW (6),
g726r16KBPS (7),
g726r24KBPS (8),
g726r32KBPS (9),
g726r40KBPS (10),
g727r16KBPS (11),
g727r24r16KBPS (12),
g727r24KBPS (13),
g727r16r32KBPS (14),
g727r32r24KBPS (15),
g727r32KBPS (16),
g727r40r16KBPS (17),
g727r40r24KBPS (18),
g727r40r32KBPS (19),
transparent (20),
netcoder6400BPS (21),
netcoder7200BPS (22),
netcoder8KBPS (23),
netcoder8800BPS (24),
netcoder9600BPS (25),
lowBitRateR2660BPS (26),
amr4750BPS (27), -- Adaptive Multirate Coders of GSM
amr5150BPS (28),
amr5900BPS (29),
amr6700BPS (30),
amr7400BPS (31),
amr7950BPS (32),
amr10200BPS (33),
amr12200BPS (34)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Coder and Rate for the Voice Compression.
In MPH: Relevant for MVC-8 card only."
::= {prtExPVc4CnfgEntry 33}
prtExPVc4DestinationNum OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination phone number: 0 to 22 digits.
Applicable for Auto Dial - ipForceConnect(6), Permanent Dial and
Auto Accept Extension Types.
Default: Null String"
::= {prtExPVc4CnfgEntry 34}
prtExPVc4DtmfRelay OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When DTMF RELAY is disabled, the DTMF digits (dialed by the user)
are transmitted as compressed voice and in the remote unit are decompressed.
When DTMF RELAY is enabled, the DTMF digits are detected at the near side and not
transmitted as voice. Instead, only an indication of what digits were
dialed are transmitted and in the far end the tone is regenerated."
::= {prtExPVc4CnfgEntry 35}
prtExPVc4DiscOnSilence OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"No. of silenced seconds after which the call will be disconected.
A value of 0 means that there will be no disconnect when there is silence.
Possible values: 0 - 900 sec."
::= {prtExPVc4CnfgEntry 36}
prtExPVc4DynamicJitter OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MVC8 uses two mechanisms to overcome the network delay.
The first one is a static jitter buffer which holds a constant buffer of up
to 300 Msec and can be controled by the JITTER parameter (prtExPVc4VarDelay).
The second one is the dynamic jitter which calculates, in real time,
the network delay and handles a jitter buffer dynamically.
The dynamic mechanism that is implemented in MVC8, was intended to overcome
network delay yet when the network bursts, the MVC8 dynamic mechanism is
not able to overcome the delay.
Therefore it is better not to use the dynamic jitter
(DISABLE - should be the default) where bursts may occur often."
::= {prtExPVc4CnfgEntry 37}
prtExPVc4EandMType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
type1 (2),
type2 (3),
type3 (4),
ssdc5 (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the signaling type on the E&M analog side.
The analog signaling includes voltage, no. of pins and other parameters."
::= {prtExPVc4CnfgEntry 38}
prtExPVc4Rate OBJECT-TYPE
SYNTAX Integer32 (0..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the Rate of the port in TS units. It is used by VF-30 card family.
0 = NA = port is not intended to be connected; therefore, no Rate."
::= {prtExPVc4CnfgEntry 39}
prtExPVc4FrameSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the maximum size in Bytes of the multiplexed frame.
In some cases this must be limited to avoid IP fragmentation,
which makes the multiplexing useless, and can also decrease
the damage in case of frame loss.
Valid range: 100..1461.
notApplicable=0."
::= {prtExPVc4CnfgEntry 40}
prtExPVc4MultiplexInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the maximum amout of time (msec.) between multiplexed frames
that are sent.
For Vmux-400/420 devices:
It defines the Payload Packetizing Interval.
Valid values: 10-90 msec.
notApplicable=0."
::= {prtExPVc4CnfgEntry 41}
prtExPVc4TransportProtocol OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ptp (2),
aal2oMpls (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transport Protocol.
ptp = point to point.
aal2oMpls = AAL2 over MPLS."
::= {prtExPVc4CnfgEntry 42}
prtExPVc4MultiFreqRelay OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables/disables Multi Frequency Signaling Detection."
::= {prtExPVc4CnfgEntry 43}
prtExPVc4MinPulseWidth OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the minimum Pulse Width in msec.
Valid values: 45-100 msec.
notApplicable=0."
::= {prtExPVc4CnfgEntry 44}
prtExPVc4MinPowerLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the minimum Power Level in dBm.
Valid values: -1..-35 dBm."
::= {prtExPVc4CnfgEntry 45}
prtExPVc4SuperTandem OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Super Tandem feature provides end to end compression
over multiple hops, solving the double compression problem
detected in Voice compressing systems.
The Super Tandem, when enabled, allows transmission of
compressed voice between a few devices and eliminates the
need to decompress an recompress it over each voice card and
PBX, thus improving voice quality and reducing delay."
::= {prtExPVc4CnfgEntry 46}
prtExPVc4DestIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the destination IP Address."
::= {prtExPVc4CnfgEntry 47}
prtExPVc4DestBundle OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the destination Bundle at the
far-end device."
::= {prtExPVc4CnfgEntry 48}
prtExPVc4SrcIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Source IP Address."
::= {prtExPVc4CnfgEntry 49}
prtExPVc4SrcIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Source IP Mask."
::= {prtExPVc4CnfgEntry 50}
prtExPVc4DefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the Default Gateway for this interface."
::= {prtExPVc4CnfgEntry 51}
prtExPVc4SigPacketInterval OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the Signaling Packetizing Interval,
which is the maximum time interval, measured in msec (milliseconds),
between multiplexed signaling frames."
::= { prtExPVc4CnfgEntry 52 }
--
-- Packet VC4 card
-- External port Dlci table
--
prtExPVc4DlciTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExPVc4DlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
at the TmpCnfg entry."
::= {prtPVc4Cnfg 2}
prtExPVc4DlciEntry OBJECT-TYPE
SYNTAX PrtExPVc4DlciEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExPVc4DlciCnfgIdx, prtExPVc4DlciSltIdx, prtExPVc4DlciPrtIdx}
::= { prtExPVc4DlciTable 1}
PrtExPVc4DlciEntry ::=
SEQUENCE {
prtExPVc4DlciCnfgIdx Integer32,
prtExPVc4DlciSltIdx INTEGER,
prtExPVc4DlciPrtIdx INTEGER,
prtExPVc4DlciValid INTEGER,
prtExPVc4DlciIConSlt INTEGER,
prtExPVc4DlciIConPrt INTEGER,
prtExPVc4DlciIConDlci Integer32,
prtExPVc4DlciTxBc INTEGER,
prtExPVc4DlciTxBe INTEGER,
prtExPVc4DlciRxBc INTEGER,
prtExPVc4DlciRxBe INTEGER,
prtExPVc4DlciPriority Integer32,
prtExPVc4DlciStatus INTEGER
}
prtExPVc4DlciCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExPVc4DlciEntry 1}
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
prtExPVc4DlciSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtExPVc4DlciEntry 2}
prtExPVc4DlciPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal port number.
VC4 cards have four external ports."
::= { prtExPVc4DlciEntry 3}
prtExPVc4DlciValid OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the attributes in this
entry are valid or not. The user can add/delete pvc (dlci
to dlci connection) by modifing this object"
::= { prtExPVc4DlciEntry 4}
prtExPVc4DlciIConSlt OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position In the Mux
(Agent) where the dlci is routed to.
In the ?004 Unit the entries io6(10)..io16) are not valid"
::= { prtExPVc4DlciEntry 5}
prtExPVc4DlciIConPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
noConnect (100),
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106) ,
inPrt7 (107) ,
inPrt8 (108) ,
inPrt9 (109) ,
inPrt10 (110) ,
inPrt11 (111) ,
inPrt12 (112)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port id which the dlci is
routed to."
::= { prtExPVc4DlciEntry 6}
prtExPVc4DlciIConDlci OBJECT-TYPE
SYNTAX Integer32 (1..991)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique internal connection dlci
number, the dlci is routed to."
::= { prtExPVc4DlciEntry 7}
prtExPVc4DlciTxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBc9600bps (3),
txBc14400bps (4),
txBc19200bps (5),
txBc28800bps (6),
txBc32000bps (7),
txBc38400bps (8),
txBc48000bps (9),
txBc56000bps (10),
txBc57600bps (11),
txBc64Kbps (12),
txBc128Kbps (13),
txBc192Kbps (14),
txBc256Kbps (15),
txBc320Kbps (16),
txBc384Kbps (17),
txBc448Kbps (18),
txBc512Kbps (19),
txBc768Kbps (20),
txBc1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
txBc16000bps (25),
txBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx committed bandwidth on
the user transmit line (or at the port receive line)."
::= { prtExPVc4DlciEntry 8}
prtExPVc4DlciTxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
txBe9600bps (3),
txBe14400bps (4),
txBe19200bps (5),
txBe28800bps (6),
txBe32000bps (7),
txBe38400bps (8),
txBe48000bps (9),
txBe56000bps (10),
txBe57600bps (11),
txBe64Kbps (12),
txBe128Kbps (13),
txBe192Kbps (14),
txBe256Kbps (15),
txBe320Kbps (16),
txBe384Kbps (17),
txBe448Kbps (18),
txBe512Kbps (19),
txBe768Kbps (20),
txBe1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
txBc16000bps (25),
txBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Tx excess bandwidth on the
user transmit line (or at the port receive line)."
::= { prtExPVc4DlciEntry 9}
prtExPVc4DlciRxBc OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBc9600bps (3),
rxBc14400bps (4),
rxBc19200bps (5),
rxBc28800bps (6),
rxBc32000bps (7),
rxBc38400bps (8),
rxBc48000bps (9),
rxBc56000bps (10),
rxBc57600bps (11),
rxBc64Kbps (12),
rxBc128Kbps (13),
rxBc192Kbps (14),
rxBc256Kbps (15),
rxBc320Kbps (16),
rxBc384Kbps (17),
rxBc448Kbps (18),
rxBc512Kbps (19),
rxBc768Kbps (20),
rxBc1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
rxBc16000bps (25),
rxBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx committed bandwidth on the
user receive line (or at the port transmit line)."
::= { prtExPVc4DlciEntry 10}
prtExPVc4DlciRxBe OBJECT-TYPE
SYNTAX INTEGER
{
full (1),
zero (2),
rxBe9600bps (3),
rxBe14400bps (4),
rxBe19200bps (5),
rxBe28800bps (6),
rxBe32000bps (7),
rxBe38400bps (8),
rxBe48000bps (9),
rxBe56000bps (10),
rxBe57600bps (11),
rxBe64Kbps (12),
rxBe128Kbps (13),
rxBe192Kbps (14),
rxBe256Kbps (15),
rxBe320Kbps (16),
rxBe384Kbps (17),
rxBe448Kbps (18),
rxBe512Kbps (19),
rxBe768Kbps (20),
rxBe1024Kbps (21),
--
--KM30 ; KM300 additional rates
--
rxBc16000bps (25),
rxBc112Kbps (26)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique Rx excess bandwidth on the
user receive line (or at the port transmit line)."
::= { prtExPVc4DlciEntry 11}
prtExPVc4DlciPriority OBJECT-TYPE
SYNTAX Integer32 (6..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique priority of the pvc.
6 is the lowest priority and 8 is the highest priority."
::= { prtExPVc4DlciEntry 12}
prtExPVc4DlciStatus OBJECT-TYPE
SYNTAX INTEGER
{
disconnected (1),
connected (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the status of the pvc. The status is
disconnected(1) when one of the sides is programmed as not
connected"
::= { prtExPVc4DlciEntry 13}
--
-- Megaplex ?000/?004 LS-6 TDM I/O family card include:
-- Ls6, Ls6V1/E, Ls6V1/O, Ls6V1/S, Ls6V2/E, Ls6V2/O, Ls6V2/S,
-- Ls6Vf/E, Ls6Vf/O, Ls6Vf/S
--
--prtExLs6CnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 1}
--prtExLs6VCnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 2}
--prtInLs6CnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 3}
--prtExLs6CnfgTable defines the parameters of the
-- LS-6 cards family external Data ports (1-6) ; LS-12 (1-12)
prtExLs6CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExLs6CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLs6Cnfg 1}
prtExLs6CnfgEntry OBJECT-TYPE
SYNTAX PrtExLs6CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExLs6CnfgIdx, prtExLs6SltIdx, prtExLs6PrtIdx }
::= {prtExLs6CnfgTable 1}
PrtExLs6CnfgEntry ::=
SEQUENCE {
prtExLs6CnfgIdx Integer32,
prtExLs6SltIdx INTEGER,
prtExLs6PrtIdx INTEGER,
prtExLs6Connect INTEGER,
prtExLs6Protocol INTEGER,
prtExLs6Rate INTEGER,
prtExLs6ClkMode INTEGER,
prtExLs6CtrlSignal INTEGER,
prtExLs6DataBits INTEGER,
prtExLs6Cts INTEGER,
prtExLs6LinkToInternal INTEGER
}
prtExLs6CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExLs6CnfgEntry 1}
prtExLs6SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExLs6CnfgEntry 2}
prtExLs6PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3) ,
exPrt4 (4) ,
exPrt5 (5) ,
exPrt6 (6) ,
exPrt7 (7) ,
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port index."
::= {prtExLs6CnfgEntry 3}
prtExLs6Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExLs6CnfgEntry 4}
prtExLs6Protocol OBJECT-TYPE
SYNTAX INTEGER
{
sync (2),
async (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the protocol.
async - can be selected only for ports 1-2."
::= {prtExLs6CnfgEntry 5}
prtExLs6Rate OBJECT-TYPE
SYNTAX INTEGER
{
r300bps (2),
r600bps (3),
r1200bps (4),
r2400bps (5),
r4800bps (6),
r7200bps (7),
r8000bps (8),
r9600bps (9),
r14400bps (10),
r16000bps (11),
r19200bps (12),
r24000bps (13),
r28800bps (14),
r32000bps (15),
r38400bps (16),
r48000bps (17),
r56000bps (18),
r57600bps (19),
r64000bps (20)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Port rates in bps.
g1 - contains the values : (2)-(6),(9),(12),(16)
g2 - contains the values : (7),(10),(14),(19)
g3 - contains the values : (8),(11),(13),(15),(17),(18),(20);
it is not applicable when using Async protocol.
Rates of pair ports (1-2, 3-4, 5-6) must be from the same
group."
::= {prtExLs6CnfgEntry 6}
prtExLs6ClkMode OBJECT-TYPE
SYNTAX INTEGER
{
dce (1),
extDce (2),
dte1 (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates a unique port operation clock mode.
It is applicable for Sync protocol only ."
::= {prtExLs6CnfgEntry 7}
prtExLs6CtrlSignal OBJECT-TYPE
SYNTAX INTEGER
{
local (2),
rts (3),
dtrAndRts (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control Signal."
::= {prtExLs6CnfgEntry 8}
prtExLs6DataBits OBJECT-TYPE
SYNTAX INTEGER
{
d6bits (1),
d7bits (2),
d8bits (3),
d9bits (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data Bits.
This object is applicable for Async protocol only."
::= {prtExLs6CnfgEntry 9}
prtExLs6Cts OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2),
rts (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the CTS control line
operation mode."
::= {prtExLs6CnfgEntry 10}
prtExLs6LinkToInternal OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101) ,
inPrt2 (102) ,
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates which internal port of the card,
the external port is linked to."
::= {prtExLs6CnfgEntry 11}
--prtExLs6VCnfgTable defines the parameters of the
-- LS-6 cards family external Voice & FAX ports (7-8)
prtExLs6VCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExLs6VCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLs6Cnfg 2}
prtExLs6VCnfgEntry OBJECT-TYPE
SYNTAX PrtExLs6VCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExLs6VCnfgIdx, prtExLs6VSltIdx, prtExLs6VPrtIdx }
::= {prtExLs6VCnfgTable 1}
PrtExLs6VCnfgEntry ::=
SEQUENCE {
prtExLs6VCnfgIdx Integer32,
prtExLs6VSltIdx INTEGER,
prtExLs6VPrtIdx INTEGER,
prtExLs6VConnect INTEGER,
prtExLs6VRate INTEGER,
prtExLs6VEchoCanceler INTEGER,
prtExLs6VIfType INTEGER,
prtExLs6VTxGain Integer32,
prtExLs6VRxGain Integer32,
prtExLs6VOos INTEGER
}
prtExLs6VCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExLs6VCnfgEntry 1}
prtExLs6VSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExLs6VCnfgEntry 2}
prtExLs6VPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt7 (7) ,
exPrt8 (8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtExLs6VCnfgEntry 3}
prtExLs6VConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExLs6VCnfgEntry 4}
prtExLs6VRate OBJECT-TYPE
SYNTAX INTEGER
{
r6400bps (2),
r7200bps (3),
r8000bps (4),
r9600bps (5),
r16000bps (6),
r24000bps (7),
r32000bps (8),
r64000bps (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate (bps) used for FAX transmission and Voice coding."
::= {prtExLs6VCnfgEntry 5}
prtExLs6VEchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation."
::= {prtExLs6VCnfgEntry 6}
prtExLs6VIfType OBJECT-TYPE
SYNTAX INTEGER
{
w2wire (1),
w4wire (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the interface type of the port.
w4wire - is applicable only for E&M port type."
::= {prtExLs6VCnfgEntry 7}
prtExLs6VTxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit gain in dBm.
E&M - values range: -17 .. 8
FXO - values range: -16 .. 4
FXS - values range: -13 .. 8 "
::= {prtExLs6VCnfgEntry 8}
prtExLs6VRxGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive gain in dBm.
E&M - values range: -17 .. 2
FXO - values range: -17 .. -1
FXS - values range: -17 .. 2 "
::= {prtExLs6VCnfgEntry 9}
prtExLs6VOos OBJECT-TYPE
SYNTAX INTEGER
{
forcedIdle (1),
forcedBusy (2),
busyIdle (3),
idleBusy (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Out of Service signaling mode."
::= {prtExLs6VCnfgEntry 10}
-- Ls6 and Ls12 Internal composite channel parameters
--
prtInLs6CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInLs6CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtLs6Cnfg 3}
prtInLs6CnfgEntry OBJECT-TYPE
SYNTAX PrtInLs6CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInLs6CnfgIdx, prtInLs6SltIdx, prtInLs6PrtIdx }
::= {prtInLs6CnfgTable 1}
PrtInLs6CnfgEntry ::=
SEQUENCE {
prtInLs6CnfgIdx Integer32,
prtInLs6SltIdx INTEGER,
prtInLs6PrtIdx INTEGER,
prtInLs6Connect INTEGER,
prtInLs6TandemMode INTEGER,
prtInLs6Rate INTEGER,
prtInLs6RemoteType INTEGER,
prtInLs6LinkTo INTEGER
}
prtInLs6CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInLs6CnfgEntry 1}
prtInLs6SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtInLs6CnfgEntry 2}
prtInLs6PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101),
inPrt2 (102)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique internal port index."
::= {prtInLs6CnfgEntry 3}
prtInLs6Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be considered in
any of the mux algorithms. It also affects all the module
considerations because the module has only one Internal
interface which is the composite channel."
::= {prtInLs6CnfgEntry 4}
prtInLs6TandemMode OBJECT-TYPE
SYNTAX INTEGER
{
noTandem (1),
tandemMaster (2),
tandemSlave (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Tandem Mode.
tandemSlave - is valid only for an LS-6 card having on
the (current slot-1) an LS-6 card with 'tandemMaster' mode."
::= {prtInLs6CnfgEntry 5}
prtInLs6Rate OBJECT-TYPE
SYNTAX INTEGER
{
r32Kbps (1),
r56Kbps (2),
r64Kpbs (3),
r128Kbps (4),
r256Kbps (5),
r384Kbps (6),
r192Kbps (7),
r512Kbps (8),
r768Kbps (9),
r14400bps(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Main Rate in Kbps."
::= {prtInLs6CnfgEntry 6}
prtInLs6RemoteType OBJECT-TYPE
SYNTAX INTEGER
{
ls6 (1),
km2kSlave (2),
km2kStandalone (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Remote Type.
notApplicable - when prtInLs6TandemMode=tandemSlave "
::= {prtInLs6CnfgEntry 7}
prtInLs6LinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"It indicates the slot of the main link card to which the
Ls6 card is mapped.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
notApplicable - when prtInLs6TandemMode=tandemSlave.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort. "
::= {prtInLs6CnfgEntry 8}
--
-- Megaplex?000/?004 VC-3 TDM I/O family port.
-- (VC3/E&M,VC3/FXO,VC3/FXS)
--
--
--prtExVc3CnfgTable defines the parameters of the
-- VC-3 and VF-3 cards family external ports
prtExVc3CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExVc3CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtVc3Cnfg 1}
prtExVc3CnfgEntry OBJECT-TYPE
SYNTAX PrtExVc3CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExVc3CnfgIdx, prtExVc3SltIdx, prtExVc3PrtIdx }
::= { prtExVc3CnfgTable 1}
PrtExVc3CnfgEntry ::=
SEQUENCE {
prtExVc3CnfgIdx Integer32,
prtExVc3SltIdx INTEGER,
prtExVc3PrtIdx INTEGER,
prtExVc3Connect INTEGER,
prtExVc3TransGain Integer32,
prtExVc3ReceiveGain Integer32,
prtExVc3Wire INTEGER,
prtExVc3Rate INTEGER,
prtExVc3EchoCanceler INTEGER
}
prtExVc3CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExVc3CnfgEntry 1}
prtExVc3SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExVc3CnfgEntry 2}
prtExVc3PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1) ,
exPrt2 (2) ,
exPrt3 (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtExVc3CnfgEntry 3}
prtExVc3Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExVc3CnfgEntry 4}
prtExVc3TransGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit gain in dBm."
::= {prtExVc3CnfgEntry 5}
prtExVc3ReceiveGain OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive gain in dBm."
::= {prtExVc3CnfgEntry 6}
prtExVc3Wire OBJECT-TYPE
SYNTAX INTEGER
{
w2wire (1),
w4wire (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is equal for all the ports in the specific
card because of HW limitations"
::= {prtExVc3CnfgEntry 7}
prtExVc3Rate OBJECT-TYPE
SYNTAX INTEGER
{
r9600bps (1),
r4800bps (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate in bps."
::= {prtExVc3CnfgEntry 8}
prtExVc3EchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation. The value will be the same for
all the card's external ports."
::= {prtExVc3CnfgEntry 9}
--prtInVc3CnfgTable defines the parameters of the
-- VC-3 or VF-3 cards family internal ports
prtInVc3CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtInVc3CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtVc3Cnfg 2}
prtInVc3CnfgEntry OBJECT-TYPE
SYNTAX PrtInVc3CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtInVc3CnfgIdx, prtInVc3SltIdx, prtInVc3PrtIdx }
::= { prtInVc3CnfgTable 1}
PrtInVc3CnfgEntry ::=
SEQUENCE {
prtInVc3CnfgIdx Integer32,
prtInVc3SltIdx INTEGER,
prtInVc3PrtIdx INTEGER,
prtInVc3Connect INTEGER,
prtInVc3Rate INTEGER,
prtInVc3Oos INTEGER,
prtInVc3LinkTo INTEGER
}
prtInVc3CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtInVc3CnfgEntry 1}
prtInVc3SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtInVc3CnfgEntry 2}
prtInVc3PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtInVc3CnfgEntry 3}
prtInVc3Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
considered in any of the mux algorithms."
::= {prtInVc3CnfgEntry 4}
prtInVc3Rate OBJECT-TYPE
SYNTAX INTEGER
{
r32000bps (1),
r16000bps (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Rate in bps."
::= {prtInVc3CnfgEntry 5}
prtInVc3Oos OBJECT-TYPE
SYNTAX INTEGER
{
forcedIdle (1),
forcedBusy (2),
busyIdle (3),
idleBusy (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object is equal for all the ports in the specific
card because of HW limitations"
::= {prtInVc3CnfgEntry 6}
prtInVc3LinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This attribute indicates the slot of the ML card to which
the VC card is mapped.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtInVc3CnfgEntry 7}
--
-- Megaplex?000/?004 VC-3 TDM I/O family port.
-- (VC-PBX, VC-PBX/T1,VC-PBX/E1)
--
--
--prtExVcPbxCnfgTable defines the parameters of the
-- VC-PBX or VF-PBX cards family external ports
prtExVcPbxCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExVcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtVcPbxCnfg 1}
prtExVcPbxCnfgEntry OBJECT-TYPE
SYNTAX PrtExVcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExVcPbxCnfgIdx, prtExVcPbxSltIdx, prtExVcPbxPrtIdx }
::= { prtExVcPbxCnfgTable 1}
PrtExVcPbxCnfgEntry ::=
SEQUENCE {
prtExVcPbxCnfgIdx Integer32,
prtExVcPbxSltIdx INTEGER,
prtExVcPbxPrtIdx INTEGER,
prtExVcPbxConnect INTEGER,
prtExVcPbxGroup INTEGER,
prtExVcPbxTransparent INTEGER,
prtExVcPbxTransSignalTs Integer32,
prtExVcPbxFrame INTEGER,
prtExVcPbxRestoreTime INTEGER,
prtExVcPbxLineCode INTEGER,
prtExVcPbxLineLength INTEGER,
prtExVcPbxLinkTo INTEGER,
prtExVcPbxSignalOper INTEGER,
prtExVcPbxIdleCode INTEGER
}
prtExVcPbxCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtExVcPbxCnfgEntry 1}
prtExVcPbxSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExVcPbxCnfgEntry 2}
prtExVcPbxPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtExVcPbxCnfgEntry 3}
prtExVcPbxConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port should be
considered in any of the mux algorithms."
::= {prtExVcPbxCnfgEntry 4}
prtExVcPbxGroup OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group object links together several VC-PBX cards,
concerning compression of the same input T1/E1 link
time-slots.
When ports of different slots have the same group, they are
linked.
When ports have a different group, they are not linked.
For VC-PBX/T1 and E1 cards, this object is - their own
IO Slot.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExVcPbxCnfgEntry 5}
prtExVcPbxTransparent OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the Transparent transfer
of Time-Slots is required or not.
Time-Slots transferred by Transparent, will not be
compressed.
no - applicable only for VC-PBX/T1 and VC-PBX/E1 cards
yes - applicable only for VC-PBX/T1 and VC-PBX/E1 cards
notApplicable - only for VC-PBX cards."
::= {prtExVcPbxCnfgEntry 6}
prtExVcPbxTransSignalTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the ML Time-Slot dedicated to
the signaling of the PABX Transparent TSs.
None = 255.
When prtExVcPbxTransparent=no this object's value=None (255)
When prtExVcPbxTransparent=notApplicable, this object's
value=None (255).
When prtExVcPbxTransparent=yes:
- for VC-PBX/T1 ports, this object's valid values are 1..16
or None (255).
- for VC-PBX/E1 ports, this object's value will be 16 or None
(255)."
::= {prtExVcPbxCnfgEntry 7}
prtExVcPbxFrame OBJECT-TYPE
SYNTAX INTEGER
{
esfT1 (2), --> dsx1ESF
sfT1 (3), --> dsx1D4
g732nE1 (4), --> dsx1E1
g732nE1CRC (5), --> dsx1E1-CRC
g732sE1 (6), --> dsx1E1-MF
g732sE1CRC (7), --> dsx1E1-MF-CRC
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the frame parameter for T1/E1 interface.
The user should select only the parameters which are relevant
to the specific card:
T1 values for the VC-PBX/T1 card.
E1 values for the VC-PBX/E1 card.
notApplicable - for the VC-PBX card.
This parameter has the same values as dsx1LineType in T1/E1
MIB (RFC-1406). The parameters in dsx1LineType are:
other (1)
esfT1 dsx1ESF (2)
sfT1 dsx1D4 (3)
g732nE1 dsx1E1 (4)
g732nE1CRC dsx1E1-CRC (5)
g732sE1 dsx1E1-MF (6)
g732sE1CRC dsx1E1-MF-CRC (7) "
::= {prtExVcPbxCnfgEntry 8}
prtExVcPbxRestoreTime OBJECT-TYPE
SYNTAX INTEGER
{
restoreT1secFast (2),
restoreT10sec62411 (3),
ccittE1 (4),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time passing from the disappearance of the loss of
synchronization condition (red alarm) to the restoration of
normal service. The options 1secFast(2) and 10sec62411(3)
for E1 interfaces are proprietary implementation of the T1
standard to the E1 interface.
ccittE1 - is applicable only for VC-PBX/E1 card
notApplicable - is applicable for VC-PBX card"
::= {prtExVcPbxCnfgEntry 9}
prtExVcPbxLineCode OBJECT-TYPE
SYNTAX INTEGER
{
b7zsT1 (1), --> dsx1JBZS
b8zsT1 (2), --> dsx1B8ZS
transT1(3), --> dsx1AMI
hdb3E1 (4), --> dsx1HDB3
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the line code parameter used for T1/E1
interface.
The user should select only the parameters which are relevant
to the specific card:
T1 line code parameters for VC-PBX/T1
E1 line code parameters for VC-PBX/E1
notApplicable - for VC-PBX
This parameter has the same values as dsx1LineCoding in T1/E1
MIB (RFC-1406). The parameters in dsx1LineCoding are:
dsx1JBZS (1)
dsx1B8ZS (2)
dsx1HDB3 (3)
dsx1ZBTSI (4)
dsx1AMI (5)
other (6)"
::= {prtExVcPbxCnfgEntry 10}
prtExVcPbxLineLength OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
len0p133ft (2),
len134p266ft (3),
len267p399ft (4),
len400p533ft (5),
len534p655ft (6),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the line length parameter.
It is applicable only for the VC-PBX/T1 card.
notApplicable - for the VC-PBX and VC-PBX/E1 card.
lenXXXpXXXft = len-XXX-XXXft."
::= {prtExVcPbxCnfgEntry 11}
prtExVcPbxLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates the slot of the ML card to which
the VC-PBX/T1, VC-PBX/E1 card Transparent TSs are mapped.
notApplicable - for VC-PBX card AND
for VC-PBX/T1, VC-PBX/E1 cards, when prtExVcPbxTransparent=no .
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtExVcPbxCnfgEntry 12}
prtExVcPbxSignalOper OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
normal (2),
bEqA (3),
inverseA (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Signaling Operation of the
VC-PBX/T1, VC-PBX/E1 external port.
notApplicable - for VC-PBX card
normal - all 4 signaling bits are transferred.
bEqA - copy the A bit into the B bit. Applicable only for
VC-PBX/T1."
::= {prtExVcPbxCnfgEntry 13}
prtExVcPbxIdleCode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
hff (2),
he4 (3),
hd5 (4),
h9e (5),
h98 (6),
h7f (7),
h7e (8),
h54 (9),
h1a (10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the code for transmission in empty time slots.
notApplicable - for VC-PBX card ."
::= {prtExVcPbxCnfgEntry 14}
--prtIn1p6VcPbxCnfgTable defines the parameters of the
-- VC-PBX or VF-PBX cards family internal ports 1-6
prtIn1p6VcPbxCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIn1p6VcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtVcPbxCnfg 2}
prtIn1p6VcPbxCnfgEntry OBJECT-TYPE
SYNTAX PrtIn1p6VcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtIn1p6VcPbxCnfgIdx, prtIn1p6VcPbxSltIdx, prtIn1p6VcPbxPrtIdx }
::= { prtIn1p6VcPbxCnfgTable 1}
PrtIn1p6VcPbxCnfgEntry ::=
SEQUENCE {
prtIn1p6VcPbxCnfgIdx Integer32,
prtIn1p6VcPbxSltIdx INTEGER,
prtIn1p6VcPbxPrtIdx INTEGER,
prtIn1p6VcPbxConnect INTEGER,
prtIn1p6VcPbxRate INTEGER,
prtIn1p6VcPbxEchoCanceler INTEGER,
prtIn1p6VcPbxPabxTs Integer32
}
prtIn1p6VcPbxCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtIn1p6VcPbxCnfgEntry 1}
prtIn1p6VcPbxSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtIn1p6VcPbxCnfgEntry 2}
prtIn1p6VcPbxPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt1 (101) ,
inPrt2 (102) ,
inPrt3 (103) ,
inPrt4 (104) ,
inPrt5 (105) ,
inPrt6 (106)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtIn1p6VcPbxCnfgEntry 3}
prtIn1p6VcPbxConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port should be
considered in any of the mux algorithms."
::= {prtIn1p6VcPbxCnfgEntry 4}
prtIn1p6VcPbxRate OBJECT-TYPE
SYNTAX INTEGER
{
r4800bps (1),
r6400bps (2),
r7200bps (3),
r8000bps (4),
r9600bps (5),
r12800bps (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port Rate.
For Normal mode (prtIn7p8VcPbxMode=normal), only part of the values
are valid (constant rate).
For Server mode (prtIn7p8VcPbxMode=server), all values are
applicable (user can select the desired compression rate). "
::= {prtIn1p6VcPbxCnfgEntry 5}
prtIn1p6VcPbxEchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation."
::= {prtIn1p6VcPbxCnfgEntry 6}
prtIn1p6VcPbxPabxTs OBJECT-TYPE
SYNTAX Integer32 (1..31)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object defines the PABX Time-Slot assigned to this
internal port.
For a T1 link, the valid values are: 1 .. 24.
For an E1 link, the valid values are: 1 .. 31.
This object is NOT applicable when prtIn1p6VcPbxConnect=no.
This object is applicable for all cards of VC-PBX family.
Default=the internal port index (1..6)."
::= {prtIn1p6VcPbxCnfgEntry 7}
--prtIn7p8VcPbxCnfgTable defines the parameters of the
-- VC-PBX or VF-PBX cards family internal ports 7-8
prtIn7p8VcPbxCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIn7p8VcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= { prtVcPbxCnfg 3}
prtIn7p8VcPbxCnfgEntry OBJECT-TYPE
SYNTAX PrtIn7p8VcPbxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtIn7p8VcPbxCnfgIdx, prtIn7p8VcPbxSltIdx, prtIn7p8VcPbxPrtIdx }
::= { prtIn7p8VcPbxCnfgTable 1}
PrtIn7p8VcPbxCnfgEntry ::=
SEQUENCE {
prtIn7p8VcPbxCnfgIdx Integer32,
prtIn7p8VcPbxSltIdx INTEGER,
prtIn7p8VcPbxPrtIdx INTEGER,
prtIn7p8VcPbxConnect INTEGER,
prtIn7p8VcPbxMode INTEGER,
prtIn7p8VcPbxRate INTEGER,
prtIn7p8VcPbxSignalMode INTEGER,
prtIn7p8VcPbxOos INTEGER,
prtIn7p8VcPbxLinkTo INTEGER
}
prtIn7p8VcPbxCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg"
::= {prtIn7p8VcPbxCnfgEntry 1}
prtIn7p8VcPbxSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtIn7p8VcPbxCnfgEntry 2}
prtIn7p8VcPbxPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
inPrt7 (107) ,
inPrt8 (108)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique identifier of the port, within the card."
::= {prtIn7p8VcPbxCnfgEntry 3}
prtIn7p8VcPbxConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the port should be
considered in any of the mux algorithms."
::= {prtIn7p8VcPbxCnfgEntry 4}
prtIn7p8VcPbxMode OBJECT-TYPE
SYNTAX INTEGER
{
normal (1),
server (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the working mode of the port:
- normal - the compressed voice will be sent to an MTML
card inside the Mux.
- server - the compressed voice will be sent to the Digital
Voice connector, as a service to an outside user."
::= {prtIn7p8VcPbxCnfgEntry 5}
prtIn7p8VcPbxRate OBJECT-TYPE
SYNTAX INTEGER
{
r32Kbps (1),
r16Kbps (2),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the port Main Rate.
For Server mode (prtIn7p8VcPbxMode=server), the value will
be notApplicable. "
::= {prtIn7p8VcPbxCnfgEntry 6}
prtIn7p8VcPbxSignalMode OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
aBit (2),
abcBit (3),
abcdBit (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Signal Mode.
For Server mode (prtIn7p8VcPbxMode=server), the only valid
values are:
- none
- aBit "
::= {prtIn7p8VcPbxCnfgEntry 7}
prtIn7p8VcPbxOos OBJECT-TYPE
SYNTAX INTEGER
{
forcedIdle (1),
forcedBusy (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Out of service Signaling mode."
::= {prtIn7p8VcPbxCnfgEntry 8}
prtIn7p8VcPbxLinkTo OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates the slot of the ML card to which
the VC card is mapped.
In the ?004 Unit the entries io6(10)..io12(16) are not valid.
For Server mode (prtIn7p8VcPbxMode=server), this object is
not applicable.
Both ports, 7 and 8 should be linked to the same Slot.
STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot
and prtGenCnfgLinkToPort."
::= {prtIn7p8VcPbxCnfgEntry 9}
--prtExVcPbxTsTable defines PABX Time Slots assignment of the
-- VC-PBX E1/T1 cards, VF-PBX cards , VF-24/30/48/60 T1/E1 cards
-- and VFS cards
prtExVcPbxTsTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtExVcPbxTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the table objects is valid only
to the TmpCnfg entry."
::= { prtVcPbxCnfg 4}
prtExVcPbxTsEntry OBJECT-TYPE
SYNTAX PrtExVcPbxTsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtExVcPbxTsCnfgIdx, prtExVcPbxTsSltIdx, prtExVcPbxTsPrtIdx, prtExVcPbxTsIdx }
::= { prtExVcPbxTsTable 1}
PrtExVcPbxTsEntry ::=
SEQUENCE {
prtExVcPbxTsCnfgIdx Integer32,
prtExVcPbxTsSltIdx INTEGER,
prtExVcPbxTsPrtIdx INTEGER,
prtExVcPbxTsIdx Integer32,
prtExVcPbxTsMode INTEGER,
prtExVcPbxTsIConSlot INTEGER,
prtExVcPbxTsIConPrt INTEGER,
prtExVcPbxTsIConTs Integer32,
prtExVcPbxTsRemPrt INTEGER,
prtExVcPbxTsRemTs Integer32,
prtExVcPbxTsRemConnID Unsigned32,
prtExVcPbxTsSourceSlot INTEGER,
prtExVcPbxTsSourcePrt Unsigned32
}
prtExVcPbxTsCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtExVcPbxTsEntry 1}
prtExVcPbxTsSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid"
::= { prtExVcPbxTsEntry 2}
prtExVcPbxTsPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
inPrt9 (109),
inPrt10 (110)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
VCPBX/E1, VCPBX/T1, VFPBX/E1, VFPBX/T1, VF-24/T1 and VF-30 cards
have only one external interface.
VF-48/T1 and VF-60/E1 cards have two external interfaces.
VFS cards have also internal ports."
::= { prtExVcPbxTsEntry 3}
prtExVcPbxTsIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique PABX time slot position.
The valid time slots are 1..24 for T1 cards and
1..31 for E1 cards."
::= { prtExVcPbxTsEntry 4}
prtExVcPbxTsMode OBJECT-TYPE
SYNTAX INTEGER
{
unused (1),
compressed (2), -- =compressedVoice
transparent (3),
compressedCcs(4),
mng (5),
ccs1 (11),
ccs2 (12),
ccs3 (13),
ccs4 (14),
ccs5 (15),
ccs6 (16),
ccs7 (17),
ccs8 (18),
ss7n1 (41),
ss7n2 (42),
ss7n3 (43),
ss7n4 (44),
ss7n5 (45),
ss7n6 (46),
ss7n7 (47),
ss7n8 (48)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the usage, process and way of the
specific PABX TS towards its destination:
unused - the TS is not used (no processing, no destination).
compressed - the TS is used, sent for compression to an
internal port (for VF-PBX cards: 1..6 for of either
the same card or a VF-PBX card of the same group).
For VF-24/30/48/60 - 'compressed' represents 'compressed Voice'
(to differentiate it from 'compressedCcs').
In this case, the TS is compressed by an internal port (1..8).
transparent - the TS is used; no processing. It is sent
directly for Bypass to a ML card the VF port/TS is linked to.
compressedCcs - supported only by VF-24/30/48/60 cards. The TS is used;
sent for compression to the CPU.
mng - the TS is used for Management (this option is used when the
external port is connected to another product that has to be
managed via this dedicated TS.
ccs1..ccs8 - supported only by VF-24/30/48/60 cards. Compressed TS that
comes from a bundle of V5.1 or V5.2 PBX.
ss7n1..ss7n8 - supported only by VF-24/30/48/60 cards. Compressed TS that
comes from a bundle of V5.1 or V5.2 PBX. ss7n1 can work versus
Vmux having prtExPh1MlTsType=ss7(6)."
::= { prtExVcPbxTsEntry 5}
prtExVcPbxTsIConSlot OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For VF-PBX cards, the io1..io12 values are applicable only when
prtExVcPbxTsMode=compressed. Otherwise, its value should be
noConnect.
For VF-24/30/48/60 cards:
- when prtExVcPbxTsMode=transparent or voiceTransparent, the io1..io12 values are applicable,
indicating the ML Slot this TS is connected to.
- when prtExVcPbxTsMode=compressed or compressedCcs, the value
will be the same as prtExVcPbxTsSltIdx, since the compression is
done within the same card.
- for rest of the prtExVcPbxTsMode values, the value will be: noConnect.
This object indicates whether the specified compressed/transparent
time slot is connected/routed internally in the Agent and
to which card it is connected.
For VF-PBX card, the valid selectable slots are either the current one,
(prtExVcPbxTsSltIdx), or a slot containing a VF-PBX card.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExVcPbxTsEntry 6}
prtExVcPbxTsIConPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
exPrt5 (5),
exPrt6 (6),
exPrt7 (7),
exPrt8 (8),
noConnect (100),
inPrt1 (101),
inPrt2 (102),
inPrt3 (103),
inPrt4 (104),
inPrt5 (105),
inPrt6 (106),
inPrt7 (107),
inPrt8 (108)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the port to which this TS is connected.
For VF-PBX cards, only inPrt1..inPrt6 ports are valid.
For VF-24/30/48/60 cards:
- for prtExVcPbxTsMode=transparent or voiceTransparent, the valid ports are
ML ports (exPrt1.. exPrt8, inPrt1.. inPrt8)
- for prtExVcPbxTsMode=compressed or compressedCcs, the valid
ports are internal ports of the same card (inPrt1..inPrt8)
noConnect - when prtExVcPbxTsIConSlot=noConnect."
::= {prtExVcPbxTsEntry 7}
prtExVcPbxTsIConTs OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the ML TS to which this TS is connected.
This object is not applicable for VF-PBX cards.
For VF-24/30/48/60 cards it is applicable only when
prtExVcPbxTsMode=transparent or voiceTransparent.
The valid time slots are 1..24 for ML T1 cards and 1..31 for ML E1 cards.
notApplicable - 255. "
::= { prtExVcPbxTsEntry 8}
prtExVcPbxTsRemPrt OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
noConnect (100)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the end-point port on the Remote unit.
VF-24/T1 and VF-30/E1 cards have one external interface.
VF-48/T1 and VF-60/E1 cards have two external interfaces.
noConnect - when prtExVcPbxTsMode=unused, transparent, voiceTransparent or mng."
::= { prtExVcPbxTsEntry 9}
prtExVcPbxTsRemTs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the end-point TS on the Remote unit.
The valid time slots are 1..24 for T1 ports and 1..31 for E1 ports.
notApplicable - 255."
::= { prtExVcPbxTsEntry 10}
prtExVcPbxTsRemConnID OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Connection ID with the Remote unit.
notApplicable = 0."
::= { prtExVcPbxTsEntry 11}
prtExVcPbxTsSourceSlot OBJECT-TYPE
SYNTAX INTEGER
{
noConnect (2),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For VFS cards. These cards offer Compresed Voice Services for
Analog Voice ports of the MP.
This object indicates the Source Slot of the Analog Voice port we want
to compress.
io1..io12 values are applicable only when prtExVcPbxTsMode=compressed(voice).
Otherwise, its value should be noConnect.
In the ?004 Unit the entries io6(10)..io12(16) are not valid."
::= {prtExVcPbxTsEntry 12}
prtExVcPbxTsSourcePrt OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For VFS cards. These cards offer Compresed Voice Services for
Analog Voice ports of the MP.
This object indicates the Source Port within the Slot of the Analog Voice Card,
we want to compress.
exPrt1 - exPrt16 = 1 - 16
noConnect=100 - when prtExVcPbxTsCvServiceSlot=noConnect."
::= {prtExVcPbxTsEntry 13}
-- The following tables contains information specific to
-- the isdn access modules
prtIsdnCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIsdnCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the table objects is valid only
to the TmpCnfg entry."
::= { prtIsdnCnfg 1}
prtIsdnCnfgEntry OBJECT-TYPE
SYNTAX PrtIsdnCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtIsdnCnfgIdx, prtIsdnSltIdx, prtIsdnPrtIdx}
::= { prtIsdnCnfgTable 1}
PrtIsdnCnfgEntry ::=
SEQUENCE {
prtIsdnCnfgIdx Integer32,
prtIsdnSltIdx INTEGER,
prtIsdnPrtIdx Integer32,
prtIsdnConnect INTEGER,
prtIsdnSignalingProtocol INTEGER,
prtIsdnBasicRateLineTopology INTEGER,
prtIsdnMode INTEGER,
prtIsdnFilter INTEGER,
prtIsdnSimultaneousCall INTEGER,
prtIsdnNumOfAbstractTerm Integer32,
prtIsdnSwitchMode INTEGER,
prtIsdnAbSide INTEGER,
prtIsdnQsigRole INTEGER,
prtIsdnInterface INTEGER,
prtIsdnCallMode INTEGER,
prtIsdnCallBackTimeout Integer32
}
prtIsdnCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtIsdnCnfgEntry 1}
prtIsdnSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10(14),
io11(15),
io12(16),
kmxMlA (103),
kmxMlB (104),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In the ?004 Unit the entries io6(10)..io12(16) are not valid
For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
::= { prtIsdnCnfgEntry 2}
prtIsdnPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
For MAXcess the values will be:
exPrt1(1),
exPrt2(2),
exPrt3(3),
exPrt4(4),
For KM-2100 the port index is calculated as follows:
100*Slot+Ch"
::= { prtIsdnCnfgEntry 3}
prtIsdnConnect OBJECT-TYPE
SYNTAX INTEGER { no(2), yes(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates if the port is connected."
::= { prtIsdnCnfgEntry 4 }
prtIsdnSignalingProtocol OBJECT-TYPE
SYNTAX INTEGER
{
other(1), etsi(3), ess4(5), ess5(6), dms100(7),
ni1(9), ni2(10), ins64(17), ins1500(18), qsig(21),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute fixes which signaling protocol
is used at this port (D-Channel).
It is equivalent to isdnSignalingProtocol
in the isdn MIB."
DEFVAL { etsi }
::= { prtIsdnCnfgEntry 5 }
prtIsdnBasicRateLineTopology OBJECT-TYPE
SYNTAX INTEGER
{
pointToPoint(1),
pointToMultipoint(2),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute is relevant for ISDN BRI only.
It is equivalent to isdnBasicRateLineTopology
in the isdn MIB."
::= { prtIsdnCnfgEntry 6 }
prtIsdnMode OBJECT-TYPE
SYNTAX INTEGER
{
dialup(1),
leased(2),
syncLeased(3),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute allows the user to configure the port as
leased(2) in case of connection to a TDM network."
::= { prtIsdnCnfgEntry 7}
prtIsdnFilter OBJECT-TYPE
SYNTAX INTEGER
{ notApplicable(1),
answerAll(2),
rejectAll(3),
selective(4),
callBack (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute allows the user to configure the port:
answerAll(2): accept all incoming calls,
rejectAll(3): reject all incoming calls,
selective(4): accept or reject according directory table.
callBack (5): In this mode the ISDN Ch will reject incoming calls
and will initiate call back to the rejected phone number."
::= { prtIsdnCnfgEntry 8}
prtIsdnSimultaneousCall OBJECT-TYPE
SYNTAX INTEGER
{ notApplicable(1),
accept(2), reject(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In case of simultaneous call (local,remote and remote,local):
accept(2): accept the incoming call,
reject(3): reject the incoming call."
::= { prtIsdnCnfgEntry 9}
prtIsdnNumOfAbstractTerm OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An object for KM2100/4 agents.
255=Not Applicable
When ISDN Standard = ETSI or NTT (European) the value should be 255 (NotApplicable)
else If ML speed is 64Kbps value should be 1.
If ML speed is 128Kbps value can be either 1 or 2 (user selection)."
::= { prtIsdnCnfgEntry 10}
prtIsdnSwitchMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
auto (2),
manual (3),
connect(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For KM2100.
auto - The call is initiated automatically by one of the IO cards connected
to KML.10(ISDN card) having ISDN Switch Mode.
manual - The call is initiated by the user manually, for KML.10
having ISDN Switch Mode (via mdlSCmd).
connect- The call is initiated 'immediately', for KML.10 having ISDN Switch Mode.
'immediately'- means: immediately after power-up (when product performed
Reset) OR, since this value appears in the active
configuration.
In this case, the call can be disconnected only by power-off of the
product or by changing this object to another value (or actual Remove
of the KML.10 relevant card).
notApplicable - For other card types."
::= { prtIsdnCnfgEntry 11}
prtIsdnAbSide OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
aSide (2),
bSide (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the QSIG side in layer 3.
This definition is from the QSIG Standard."
::= { prtIsdnCnfgEntry 12}
prtIsdnQsigRole OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
slave (2),
master (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the QSIG side in layer 1 & 2."
::= { prtIsdnCnfgEntry 13}
prtIsdnInterface OBJECT-TYPE
SYNTAX INTEGER
{
lt (1),
nt (2),
te (3),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"It indicates the interface type:
lt = line termination
nt = network termination
te = terminal equipment."
::= { prtIsdnCnfgEntry 14}
prtIsdnCallMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
initiate (2),
listen (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the acceptance of incoming calls.
Initiate - Callout
Listen - Callin. "
::= { prtIsdnCnfgEntry 15}
prtIsdnCallBackTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only if 'prtIsdnFilter' is 'CallBack'
and determines how long to wait from receiving the incoming call
until initiating the call back call.
The vaules range should be '1..20 sec' and the default 10 sec."
::= { prtIsdnCnfgEntry 16}
prtIsdnEndpointTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIsdnEndpointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the table objects is valid only
to the TmpCnfg entry."
::= { prtIsdnCnfg 2}
prtIsdnEndpointEntry OBJECT-TYPE
SYNTAX PrtIsdnEndpointEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtIsdnEndpointCnfgIdx, prtIsdnEndpointSltIdx,
prtIsdnEndpointPrtIdx, prtIsdnEndpointIdx }
::= { prtIsdnEndpointTable 1}
PrtIsdnEndpointEntry ::=
SEQUENCE {
prtIsdnEndpointCnfgIdx Integer32,
prtIsdnEndpointSltIdx INTEGER,
prtIsdnEndpointPrtIdx Integer32,
prtIsdnEndpointIdx INTEGER,
prtIsdnEndpointTeiType INTEGER,
prtIsdnEndpointTeiValue Integer32,
prtIsdnEndpointSpid DisplayString,
prtIsdnEndpointBearerCh INTEGER,
prtIsdnEndpointRowStatus RowStatus
}
prtIsdnEndpointCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtIsdnEndpointEntry 1}
prtIsdnEndpointSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1(5),
io2(6),
io3(7),
io4(8),
io5(9),
io6(10),
io7(11),
io8(12),
io9(13),
io10(14),
io11(15),
io12(16),
kmxMlA (103),
kmxMlB (104),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
In ?004 Unit the entries io6(10)..io12(16) are not valid
For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
::= { prtIsdnEndpointEntry 2}
prtIsdnEndpointPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
For MAXcess the values will be:
exPrt1(1),
exPrt2(2),
exPrt3(3),
exPrt4(4),
For KM-2100 the port index is calculated as follows:
100*Slot+Ch"
::= { prtIsdnEndpointEntry 3}
prtIsdnEndpointIdx OBJECT-TYPE
SYNTAX INTEGER { atei1(1), atei2(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Since more than one endpoint may be defined per
isdn entity, this field is a simple index.
It corresponds to isdnEndpointIdx in the isdn MIB."
-- DEFVAL { atei1 }
::= { prtIsdnEndpointEntry 4}
prtIsdnEndpointTeiType OBJECT-TYPE
SYNTAX INTEGER { dynamic(1), static(2), notApplicable(255) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of TEI (Terminal Endpoint Identifier)
used for this Terminal Endpoint. In case of dynamic(1),
the TEI value is selected by the switch. In
case of static(2), a valid TEI value has to be
entered in the isdnEndpointTeiValue object.
interface type as well as the Terminal Endpoint type.
static(2). On Basic Rate interfaces the default value
is dynamic(1) for isdn(63) Terminal Endpoints.
It corresponds to isdnEndpointTeiType in the isdn MIB."
::= { prtIsdnEndpointEntry 5}
prtIsdnEndpointTeiValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"When the TEI Type is static, the value of the TEI should be
between 0 and 63. Else, it is not selectable by user.
255 = notApplicable.
It corresponds to isdnEndpointTeiValue in the isdn MIB"
::= { prtIsdnEndpointEntry 6 }
prtIsdnEndpointSpid OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Service profile IDentifier (SPID) information
for this Terminal Endpoint. It is is composed of
9-20 numeric characters.
It corresponds to isdnEndpointSpid in the isdn MIB."
::= { prtIsdnEndpointEntry 7 }
prtIsdnEndpointBearerCh OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
anyChannel (2),
channelB1 (3),
channelB2 (4) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the selected dialing channel.
anyChannel - the system selects the dialing channel."
::= { prtIsdnEndpointEntry 8}
prtIsdnEndpointRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This field indicates whether to consider this endpoint or not.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { prtIsdnEndpointEntry 9}
prtIsdnDirectoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIsdnDirectoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the table objects is valid only
to the TmpCnfg entry."
::= { prtIsdnCnfg 3}
prtIsdnDirectoryEntry OBJECT-TYPE
SYNTAX PrtIsdnDirectoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtIsdnDirectoryCnfgIdx, prtIsdnDirectorySltIdx, prtIsdnDirectoryPrtIdx }
::= { prtIsdnDirectoryTable 1}
PrtIsdnDirectoryEntry ::=
SEQUENCE {
prtIsdnDirectoryCnfgIdx Integer32,
prtIsdnDirectorySltIdx INTEGER,
prtIsdnDirectoryPrtIdx Integer32,
prtIsdnDirectoryLocalAddr DisplayString,
prtIsdnDirectoryLocalSubAddr DisplayString,
prtIsdnDirectoryRemoteAddr DisplayString,
prtIsdnDirectoryRemoteSubAddr DisplayString,
prtIsdnDirectoryPrtNu Integer32,
prtIsdnDirectoryTeiId Integer32,
prtIsdnDirectoryRowStatus RowStatus,
prtIsdnDirectoryLocalAddr2 DisplayString,
prtIsdnDirectoryLocalSubAddr2 DisplayString,
prtIsdnDirectoryRemoteAddr2 DisplayString,
prtIsdnDirectoryRemoteSubAddr2 DisplayString
}
prtIsdnDirectoryCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtIsdnDirectoryEntry 1}
prtIsdnDirectorySltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1(5),
io2(6),
io3(7),
io4(8),
io5(9),
io6(10),
io7(11),
io8(12),
io9(13),
io10(14),
io11(15),
io12(16),
kmxMlA (103),
kmxMlB (104),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the card is inserted.
For MX300/30 ports:
io1(5) = isdn1(5) and io2(6) = isdn2(6).
In ?004 Unit the entries io6(10)..io12(16) are not valid
For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'"
::= { prtIsdnDirectoryEntry 2}
prtIsdnDirectoryPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For MAXcess this is the internal port number: 101, 102,....
For KM-2100 the port index is calculated as follows:
100*Slot+Ch"
::= { prtIsdnDirectoryEntry 3}
prtIsdnDirectoryLocalAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(17..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the local address associated with this
entry.
- For MX: Size=17 , Default=0 (17 characters)
- For KM: Size=20, Default=blank (20 characters) "
::= { prtIsdnDirectoryEntry 4}
prtIsdnDirectoryLocalSubAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..6))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the local subaddress associated with this
entry.
- For MX: Size=6 , Default=0 (6 characters)
- For KM: Size=4 , Default=blank (4 characters)"
::= { prtIsdnDirectoryEntry 5}
prtIsdnDirectoryRemoteAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(17..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the remote address associated with this
entry.
- For MX: Size=17 , Default=0 (17 characters)
- For KM: Size=20, Default=blank (20 characters)"
::= { prtIsdnDirectoryEntry 6}
prtIsdnDirectoryRemoteSubAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..6))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the remote subaddress associated with this
entry.
- For MX: Size=6 , Default=0 (6 characters)
- For KM: Size=4 , Default=blank (4 characters)"
::= { prtIsdnDirectoryEntry 7}
prtIsdnDirectoryPrtNu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the external port number connected to
this entry."
DEFVAL { 1 }
::= { prtIsdnDirectoryEntry 8}
prtIsdnDirectoryTeiId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the abstract terminal id if relevant,
connected to this entry."
DEFVAL { 1 }
::= { prtIsdnDirectoryEntry 9}
prtIsdnDirectoryRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the status for the row. It allows to know
whether to consider this row or not.
The only possible supported RowStatus vaules are
active (1) and destroy (6)."
::= { prtIsdnDirectoryEntry 10}
prtIsdnDirectoryLocalAddr2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(17..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the second local address associated with this
entry.
- For MX: Size=17 , Default=0 (17 characters)
- For KM: Size=20, Default=blank (20 characters)"
::= { prtIsdnDirectoryEntry 11}
prtIsdnDirectoryLocalSubAddr2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..6))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the second local subaddress associated with this
entry.
- For MX: Size=6 , Default=0 (6 characters)
- For KM: Size=4 , Default=blank (4 characters)"
::= { prtIsdnDirectoryEntry 12}
prtIsdnDirectoryRemoteAddr2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(17..20))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the second remote address associated with this
entry.
- For MX: Size=17 , Default=0 (17 characters)
- For KM: Size=20, Default=blank(20 characters) "
::= { prtIsdnDirectoryEntry 13}
prtIsdnDirectoryRemoteSubAddr2 OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..6))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the second remote subaddress associated with this
entry.
- For MX: Size=6 , Default=0 (6 characters)
- For KM: Size=4 , Default=blank (4 characters) "
::= { prtIsdnDirectoryEntry 14}
-- This table is an extension for new version of MAXcess
-- modules.
prtFrPlusCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtFrPlusCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table Objects is valid only
to the TmpCnfg entry."
::= {prtFrPlusCnfg 1}
prtFrPlusCnfgEntry OBJECT-TYPE
SYNTAX PrtFrPlusCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtFrPlusCnfgIdx, prtFrPlusSltIdx, prtFrPlusPrtIdx }
::= { prtFrPlusCnfgTable 1}
PrtFrPlusCnfgEntry ::=
SEQUENCE {
prtFrPlusCnfgIdx Integer32,
prtFrPlusSltIdx INTEGER,
prtFrPlusPrtIdx Integer32,
prtFrPlusNotSegmentedPriorities OCTET STRING
}
prtFrPlusCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. "
::= { prtFrPlusCnfgEntry 1}
prtFrPlusSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot Index.
For ISDN BRI Ports of MX300/30,
io1(5) = isdn1(5) and io2(6) = isdn2(6)."
::= { prtFrPlusCnfgEntry 2}
prtFrPlusPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number.
This port number should be:
- for ISDN cards: inPrt1(101)->inPrt50(150)
- for MHS1 card : exPrt1(1)
- for MHS3, MLS3 cards: exPrt1(1)->exPrt3(3)
- for MLS6 cards: exPrt1(1)->exPrt6(6)."
::= { prtFrPlusCnfgEntry 3}
prtFrPlusNotSegmentedPriorities OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is relevant only for FR+ protocol and
asks the MXcess NOT to segment data with specified
priorities: from LSB:
bit 1 is for priority 1,
bit 2 is for priority 2, .... till bit 7 for priority 7.
- a priority selected to be segmented : its bit will be '0'
- a priority not to be segmented : its bit will be '1'
Default is 00000000; i.e, segment all priorities."
DEFVAL { '00'H }
::= { prtFrPlusCnfgEntry 4 }
-- This table is an extension of prtExPh1MlCnfgTable for MTML cards
-- of MP-2200 and MP-2100
prtMl4CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtMl4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is an extension table for MTML-4 card parameters."
::= {prtMl4Cnfg 1}
prtMl4CnfgEntry OBJECT-TYPE
SYNTAX PrtMl4CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtMl4CnfgIdx, prtMl4SltIdx, prtMl4PrtIdx }
::= { prtMl4CnfgTable 1}
PrtMl4CnfgEntry ::=
SEQUENCE {
prtMl4CnfgIdx Integer32,
prtMl4SltIdx INTEGER,
prtMl4PrtIdx INTEGER,
prtMl4SigProfile INTEGER,
prtMl4CGA INTEGER,
prtMl4Oos INTEGER,
prtMl4VoiceOos OCTET STRING,
prtMl4DataOos OCTET STRING,
prtMl4Service INTEGER,
prtMl4IpAddress IpAddress,
prtMl4IpMask IpAddress,
prtMl4SignalingMode INTEGER,
prtMl4EchoCanceler INTEGER,
prtMl4OosErrorSource INTEGER,
prtMl4OosEntryThreshold Integer32,
prtMl4OosExitThreshold Integer32,
prtMl4LogicalLinkId Integer32,
prtMl4DedicatedTs Integer32,
prtMl4RemCrc INTEGER,
prtMl4CrossConnectLevel INTEGER,
prtMl4PppEchoFailDetection INTEGER,
prtMl4EcanCasControl INTEGER
}
prtMl4CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. The write operation is valid only
to the TmpCnfg."
::= { prtMl4CnfgEntry 1}
prtMl4SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
clA (3),
clB (4),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted."
::= { prtMl4CnfgEntry 2}
prtMl4PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
exPrt5 (5),
exPrt6 (6),
exPrt7 (7),
exPrt8 (8),
inPrt1 (101),
inPrt2 (102),
inPrt3 (103),
inPrt4 (104),
inPrt5 (105),
inPrt6 (106),
inPrt7 (107),
inPrt8 (108),
inPrt9 (109),
inPrt10 (110),
inPrt11 (111),
inPrt12 (112),
inPrt13 (113),
inPrt14 (114),
inPrt15 (115),
inPrt16 (116),
inPrt17 (117),
inPrt18 (118),
inPrt19 (119),
inPrt20 (120),
inPrt21 (121),
inPrt22 (122),
inPrt23 (123),
inPrt24 (124),
inPrt25 (125),
inPrt26 (126),
inPrt27 (127),
inPrt28 (128),
inPrt29 (129),
inPrt30 (130),
inPrt31 (131),
inPrt32 (132),
inPrt33 (133),
inPrt34 (134),
inPrt35 (135),
inPrt36 (136),
inPrt37 (137),
inPrt38 (138),
inPrt39 (139),
inPrt40 (140),
inPrt41 (141),
inPrt42 (142),
inPrt43 (143),
inPrt44 (144),
inPrt45 (145),
inPrt46 (146),
inPrt47 (147),
inPrt48 (148),
inPrt49 (149),
inPrt50 (150),
inPrt51 (151),
inPrt52 (152),
inPrt53 (153),
inPrt54 (154),
inPrt55 (155),
inPrt56 (156),
inPrt57 (157),
inPrt58 (158),
inPrt59 (159),
inPrt60 (160),
inPrt61 (161),
inPrt62 (162),
inPrt63 (163),
inPrt64 (164),
inPrt65 (165),
inPrt66 (166),
inPrt67 (167),
inPrt68 (168),
inPrt69 (169),
inPrt70 (170),
inPrt71 (171),
inPrt72 (172),
inPrt73 (173),
inPrt74 (174),
inPrt75 (175),
inPrt76 (176),
inPrt77 (177),
inPrt78 (178),
inPrt79 (179),
inPrt80 (180),
inPrt81 (181),
inPrt82 (182),
inPrt83 (183),
inPrt84 (184)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtMl4CnfgEntry 3}
prtMl4SigProfile OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
p1 (3),
p2 (4),
p3 (5),
p4 (6),
p5 (7),
perTS (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Signaling Profile of the port.
none - when the Frame is G732N (no MF) or Unframed.
p1 = profile 1
p2 = profile 2
p3 = profile 3
p4 = profile 4
p5 = profile 5
perTS = when Signaling Profile is selected per TS."
::= {prtMl4CnfgEntry 4}
prtMl4CGA OBJECT-TYPE
SYNTAX INTEGER {
none (1),
trans(2),
full (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object selects the method used to signal the CGA state
to the other end, through the main link.
'none' - non-transparent mode. When one of the links
(main) will be in Out Of Service state, both
'Data/Voice Oos' and 'Oos' will be
transmitted to the other end.
'trans' - when one of the links (main) will be in Out
Of Service state, 'Data/Voice Oos' will be
transmitted to the other end.
'full' - fully-transparent mode. When one of the links
(main) will be in Out Of Service state,
neither 'Data/Voice Oos' nor 'Oos' will
be transmitted to the other end."
::= { prtMl4CnfgEntry 5 }
prtMl4Oos OBJECT-TYPE
SYNTAX INTEGER
{
notSupported (2),
forcedIdle (3),
forcedBusy (4),
busyIdle (5),
idleBusy (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"'idle' = '0' = on-hook, idle state
'busy' = '1' = off-hook, busy state
'forcedIdle' = SP = both A and B signaling bits are forced
to '0' during out-of-service periods.
'forcedBusy' = MK = both A and B signaling bits are forced
to '1' during out-of-service periods.
'busyIdle' = MK_SP = A and B bits are forced to '1' for
2.5 seconds; then they are switched to '0'
until out-of-service condition disappears.
'idleBusy' = SP_MK = A and B bits are forced to '0' for
2.5 seconds; then they are switched to '1'
until out-of-service condition disappears.
- for T1: '0'=0 ; '1'=1
- for E1: '0'=1 ; '1'=0 "
::= { prtMl4CnfgEntry 6 }
prtMl4VoiceOos OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Voice Out-Of-Service code. Valid range: (0 - FF HEX).
For agents that do not support this feature, the value will
always be 0."
::= { prtMl4CnfgEntry 7 }
prtMl4DataOos OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Data Out-Of-Service code. Valid range: (0 - FF HEX).
For agents that do not support this feature, the value will
always be 0."
::= { prtMl4CnfgEntry 8 }
prtMl4Service OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
leasedLine (2),
v51 (3),
v52Master (4),
v52Slave (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Link Service.
leasedLine - usual TDM interface.
v51 - V5.1 interface.
v52Master - V5.2 Link to Local Exchange.
v52Slave - a ML that is transferred to the v52Master."
::= {prtMl4CnfgEntry 9}
prtMl4IpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP Address of the port."
::= {prtMl4CnfgEntry 10}
prtMl4IpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IP subnet mask of the port."
::= {prtMl4CnfgEntry 11}
prtMl4SignalingMode OBJECT-TYPE
SYNTAX INTEGER { notApplicable(1),
cas(2),
ccs(3),
robbedBit(4),
other (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Refers to the signaling mode of the port (or framer module).
notApplicable(1)- means that no framer is needed for this port (no signaling),
or that this object is not relevant.
cas(2) means Channel Associated Signaling. Used for E1 Links.
ccs(3) is the Common Channel Signaling (the signaling is not within
the channels time slot - a TS for signaling is used).
robbedBit(4) is a method implementing 7 bits for the voice and 1 bit
dedicated for signaling. Used for T1 Links.
other (5)- Signaling generally exists though not specifically according
to one of the values listed ; this port uses a framer in this case."
::= {prtMl4CnfgEntry 12}
prtMl4EchoCanceler OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Echo canceler activation."
::= {prtMl4CnfgEntry 13}
prtMl4OosErrorSource OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
framing (3),
bpv (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OOS (Out-of-Service) Error Source.
This object is applicable for T1 ports only."
::= {prtMl4CnfgEntry 14}
prtMl4OosEntryThreshold OBJECT-TYPE
SYNTAX Integer32 (0..999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the number of Errors per Second that determine the
minimum unacceptable noise level. This value will be the Entry Threshold
to the OOS (Out-of-Service) state.
This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4).
0=notApplicable."
::= { prtMl4CnfgEntry 15}
prtMl4OosExitThreshold OBJECT-TYPE
SYNTAX Integer32 (0..99)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines the number of consecutive Error-Free-Seconds before
going from OOS state to Normal state. This value will be the Exit Threshold
from the OOS (Out-of-Service) state.
Units=seconds
This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4).
0=notApplicable."
::= { prtMl4CnfgEntry 16}
prtMl4LogicalLinkId OBJECT-TYPE
SYNTAX Integer32 (0..257)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object defines for a V5.2 Master ML the Logical Link Id.
Valid values are: 0..256.
NA=257."
::= { prtMl4CnfgEntry 17}
prtMl4DedicatedTs OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A unique number to identify Dedicated TS of the E1 port (V5.2).
It is applicable only when prtMl4Service=v52Slave and
prtExPh1MlInbandMng selected is dedicatedTs, dedicatedPpp or dedicatedFr.
1..31 - Dedicated TS of E1
255 - notApplicable
Other values are invalid."
::= { prtMl4CnfgEntry 18}
prtMl4RemCrc OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the E1 of the Remote device
connected to this E1 port, will have CRC-4 or not."
::= { prtMl4CnfgEntry 19 }
prtMl4CrossConnectLevel OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
ds0 (2),
ds1 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the cross connect is
on DS1 or DS0 (time-slots) level.
When cross connect level is ds1, Destination Slot
is indicated by prtGenCnfgLinkToSlot,
Destination Port is indicated by prtGenCnfgLinkToPort.
For Unframed Line Type, cross connect level can be either
notApplicable (NC=not connected) or DS1.
Otherwise, default value is ds0."
::= { prtMl4CnfgEntry 20 }
prtMl4PppEchoFailDetection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether the PPP Echo is taken into account
for its Fail Detection.
This object is relevant when Inband Mng between devices is Dedicated TS PPP.
Default=Disable.
Enable - will be selected mainly when a T1/E1 Ring exists and between 2 adjacent
Ring devices there is another device or Net, that causes these Ring devices
not to sense that the PPP connection between them is lost. In this case,
Echo Request should be initiated by the port."
::= { prtMl4CnfgEntry 21 }
prtMl4EcanCasControl OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables/disables ECAN (Echo Canceller) control activation/deactivation
sent via the A, B, C, D multiframe signaling BITs."
::= { prtMl4CnfgEntry 22 }
--prtAcmCnfgTable defines the parameters of the
--ACM cards family external ports 1-8
prtAcmCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtAcmCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table for ACM port parameters."
::= {prtAcmCnfg 1}
prtAcmCnfgEntry OBJECT-TYPE
SYNTAX PrtAcmCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtAcmCnfgIdx, prtAcmSltIdx, prtAcmPrtIdx }
::= { prtAcmCnfgTable 1}
PrtAcmCnfgEntry ::=
SEQUENCE {
prtAcmCnfgIdx Integer32,
prtAcmSltIdx INTEGER,
prtAcmPrtIdx INTEGER,
prtAcmConnect INTEGER,
prtAcmActiveState INTEGER,
prtAcmAlrString DisplayString
}
prtAcmCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. The write operation is valid only
to the TmpCnfg."
::= { prtAcmCnfgEntry 1}
prtAcmSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16),
notApplicable (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted."
::= { prtAcmCnfgEntry 2}
prtAcmPrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2),
exPrt3 (3),
exPrt4 (4),
exPrt5 (5),
exPrt6 (6),
exPrt7 (7),
exPrt8 (8) ,
exPrt9 (9) ,
exPrt10 (10) ,
exPrt11 (11) ,
exPrt12 (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtAcmCnfgEntry 3}
prtAcmConnect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
connected or not. Only a connected port can perform activity."
::= {prtAcmCnfgEntry 4}
prtAcmActiveState OBJECT-TYPE
SYNTAX INTEGER
{
low (2),
high (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the Electric Active State of the port."
::= {prtAcmCnfgEntry 5}
prtAcmAlrString OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..35))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm string selected by user for the Inbound ports.
This object is applicable only for the Inbound Ports: ext-5..ext-12.
For the Outbound Ports (ext-1..ext-4), the size of this string will be 0."
::= {prtAcmCnfgEntry 6}
--prtE2CnfgTable defines the parameters of the
--E2 card ports
prtE2CnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtE2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table for E2 port parameters."
::= {prtE2Cnfg 1}
prtE2CnfgEntry OBJECT-TYPE
SYNTAX PrtE2CnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtE2CnfgIdx, prtE2SltIdx, prtE2PrtIdx }
::= { prtE2CnfgTable 1}
PrtE2CnfgEntry ::=
SEQUENCE {
prtE2CnfgIdx Integer32,
prtE2SltIdx INTEGER,
prtE2PrtIdx INTEGER,
prtE2Connect INTEGER,
prtE2MngOnNationalBit INTEGER
}
prtE2CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. The write operation is valid only
to the TmpCnfg."
::= { prtE2CnfgEntry 1}
prtE2SltIdx OBJECT-TYPE
SYNTAX INTEGER
{
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique slot position where
the module is inserted."
::= { prtE2CnfgEntry 2}
prtE2PrtIdx OBJECT-TYPE
SYNTAX INTEGER
{
exPrt1 (1),
exPrt2 (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates a unique port number."
::= { prtE2CnfgEntry 3}
prtE2Connect OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether the port should be
connected or not. Only a connected port can perform activity."
::= {prtE2CnfgEntry 4}
prtE2MngOnNationalBit OBJECT-TYPE
SYNTAX INTEGER
{
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates whether National Bit will be used for
Management or not."
::= {prtE2CnfgEntry 5}
--prtLanWanCnfgTable defines the parameters of the Lan-Wan ports
--(for HS-ETUB MP card)
prtLanWanCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtLanWanCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a table for Lan-Wan port parameters."
::= {prtLanWanCnfg 1}
prtLanWanCnfgEntry OBJECT-TYPE
SYNTAX PrtLanWanCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtLanWanCnfgIdx, prtLanWanSltIdx, prtLanWanPrtIdx }
::= { prtLanWanCnfgTable 1}
PrtLanWanCnfgEntry ::=
SEQUENCE {
prtLanWanCnfgIdx Integer32,
prtLanWanSltIdx INTEGER,
prtLanWanPrtIdx Integer32,
prtLanWanMode INTEGER,
prtLanWanDestIf Integer32,
prtLanWanEgressVlanMode INTEGER,
prtLanWanL2Protocol INTEGER,
prtLanWanStpPriority Integer32,
prtLanWanStpCost Integer32,
prtLanWanToLanVlanMode INTEGER,
prtLanWanVlanId Integer32,
prtLanWanVlanPriority Integer32,
prtLanWanMtu Integer32,
prtLanWanVlanType INTEGER
}
prtLanWanCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the Cnfg (1..100) being
accessed.
Idx 255 relates to the TmpCnfg. The write operation is valid only
to the TmpCnfg."
::= {prtLanWanCnfgEntry 1}
prtLanWanSltIdx OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
io1 (5),
io2 (6),
io3 (7),
io4 (8),
io5 (9),
io6 (10),
io7 (11),
io8 (12),
io9 (13),
io10 (14),
io11 (15),
io12 (16)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique slot position where the module is inserted."
::= {prtLanWanCnfgEntry 2}
prtLanWanPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique number to identify a port
in a specific card.
Generally, for MP-210X/2200, the Port Index will be according to the
external/internal port number:
- exPrtX : X
- inPrtX : 100 + X
For FCD-155, refer to device specification"
::= {prtLanWanCnfgEntry 3}
prtLanWanMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
bridge (2),
bridgeAndStp (3),
layer3SubnetSwitch(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the working mode of this port.
For FCD155, layer3SubnetSwitch is not applicable"
::= {prtLanWanCnfgEntry 4}
prtLanWanDestIf OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the Destination Interface for the frames
received by this port.
- Switching Table = 100 (it means that the destination interface
will be determined by the Switching Table)
- inPrtX (internal-X port): 100 + X .
For FCD-155 this object is not applicable =0 "
::= {prtLanWanCnfgEntry 5}
prtLanWanEgressVlanMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unmodified (2),
tag (3),
doubleTag (4),
untag (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines what to do with the VLAN frames that exit
via the WAN side of the port.
This object is not applicable when prtLanWanMode=l3SubnetSwitch(4)."
::= {prtLanWanCnfgEntry 6}
prtLanWanL2Protocol OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
ppp (3),
hdlc (4),
pppoHdlc (5),
mlppp (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"L2 Protocol.
When prtLanWanMode=l3SubnetSwitch(4), the only valid value is ppp(3)."
::= {prtLanWanCnfgEntry 7}
prtLanWanStpPriority OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of the priority field which is contained in the first
(in network byte order) octet of the (2 octet long) Port ID."
::= {prtLanWanCnfgEntry 8}
prtLanWanStpCost OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The contribution of this port to the path cost of paths towards
the spanning tree root which include this port. 802.1D-1990 recommends
that the default value of this parameter be in inverse proportion
to the speed of the attached LAN."
::= {prtLanWanCnfgEntry 9}
prtLanWanToLanVlanMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unmodified (2),
tag (3),
doubleTag (4),
untag (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines what to do with the VLAN frames that come from
WAN side of the port and exit towards one of the LAN ports.
This object is applicable only when prtLanWanDestIf=100 or 101
(Switching Table or inPrt1)."
::= {prtLanWanCnfgEntry 10}
prtLanWanVlanId OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the VLAN Id attached to a frame, when the relevant
Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is
tag or doubleTag.
0=not applicable."
::= {prtLanWanCnfgEntry 11}
prtLanWanVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the VLAN Priority attached to a frame, when the relevant
Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is
tag or doubleTag.
Valid values: 0..7
255=not applicable."
::= {prtLanWanCnfgEntry 12}
prtLanWanMtu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The size of the largest packet which can be sent/received on the interface,
specified in octets.
Valid values change per device.
0=not applicable."
::= {prtLanWanCnfgEntry 13}
prtLanWanVlanType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
portBasedVlan (2),
ieee802dot1q (3),
ieee802dot1qTaggedOnly (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This oject indicates type of VLAN this port is assigned to.
Port Base Vlan parameters are defined by objects under
radBridgePortBaseVlan"
::= { prtLanWanCnfgEntry 14}
--
-- The following table includes the IP addresses of all the NMS to which
-- Traps will be sent
--
--mngTrapIpTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF MngTrapIpEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "This table indicates the destination address of the traps.
-- Internally it will be limited to ten addresses. "
-- ::= { agnt 7 }
--
--mngTrapIpEntry OBJECT-TYPE
-- SYNTAX MngTrapIpEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- INDEX { mngTrapIpIdx }
-- ::= { mngTrapIpTable 1 }
--
--MngTrapIpEntry ::=
-- SEQUENCE {
-- mngTrapIpIdx Integer32,
-- mngTrapIpIP IpAddress,
-- mngTrapIpIPMask IpAddress
-- }
--
--mngTrapIpIdx OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- " This value indicates an index of a specific IP address"
-- ::= { mngTrapIpEntry 1 }
--
--mngTrapIpIP OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "This value indicates the destination addresses of the traps. "
-- ::= { mngTrapIpEntry 2 }
--
--mngTrapIpIPMask OBJECT-TYPE
-- SYNTAX IpAddress
-- MAX-ACCESS read-write
-- STATUS current
-- DESCRIPTION
-- "This value indicates the mask of the destination addresses of the traps. "
-- ::= { mngTrapIpEntry 3 }
--
--
-- Traps
--NOTIFICATIONS
muxHubEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for ."
::= { muxHub 0 }
alarmsTrap NOTIFICATION-TYPE
OBJECTS { alrBufDescription }
STATUS current
DESCRIPTION
"This trap is sent whenever alarm occurs in the agent."
::= { muxHubEvents 1 }
sanityTrap NOTIFICATION-TYPE
OBJECTS { agnSSanityCheckStatus, agnCSaveCnfgIdxCmd }
STATUS current
DESCRIPTION
"This trap is sent after a data base update.
It returns the sanity result status and the configuration no.
checked.
If the result is of Flip DB Sanity Check, the configuration
no. sent will be 0.
If the result is of Variant Sanity Check, the configuration
no. sent will be 100."
::= { muxHubEvents 2 }
cnfgFlipTrap NOTIFICATION-TYPE
OBJECTS { agnSActiveCnfg }
STATUS current
DESCRIPTION
"This trap is sent upon change of the active Configuration DB.
Attached, is the new active Configuration no."
::= { muxHubEvents 3 }
flipDbChangeTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon change of the active Flip tables
(Flip DB)."
::= { muxHubEvents 4 }
statusChangedTrap NOTIFICATION-TYPE
OBJECTS { agnLed }
STATUS current
DESCRIPTION
"This trap is sent upon any change of the LEDs status."
::= { muxHubEvents 5 }