RAD-Mpmx-MIB DEFINITIONS ::= BEGIN -- It is RAD's intent to encourage the widespread use of -- this Specification in connection with the management of -- RAD products. RAD grants vendors, end-users, -- and other interested parties a non-exclusive license to -- use this Specification in connection with the management -- of RAD products. -- This Specification is supplied "as is," and RAD makes -- no warranty, either express or implied, as to the use, -- operation, condition, or performance of the Specification. IMPORTS ifAlias, ifIndex FROM IF-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB Integer32, Counter32, IpAddress, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-IDENTITY FROM SNMPv2-SMI DisplayString, RowStatus, TruthValue FROM SNMPv2-TC radWan, wanGen FROM RAD-SMI-MIB agnLed, alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription, alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason FROM RAD-GEN-MIB CardType, ProtectLastSwitchReasonType FROM RAD-TC; chasWanGen MODULE-IDENTITY LAST-UPDATED "201609182024Z" -- September 18, 2016 ORGANIZATION "RAD Data Communications Ltd." CONTACT-INFO "System Department Email: mibs@rad.com Postal: RAD Data Communications Ltd. 24 Raoul Wallenberg St. Tel-Aviv 6971920 Israel Phone: +972-3-645-5421 Fax: +972-3-760-7844" DESCRIPTION "Megaplex Maccess MIB." ::= { wanGen 1 } muxHub OBJECT IDENTIFIER ::= {radWan 2} -- ---------------------------------------------------------------------------------------------- -- chasWanGen OBJECT IDENTIFIER ::= {wanGen 1} agnWanGen OBJECT IDENTIFIER ::= {wanGen 2} mdlWanGen OBJECT IDENTIFIER ::= {wanGen 3} prtWanGen OBJECT IDENTIFIER ::= {wanGen 4} mapWanGen OBJECT IDENTIFIER ::= {wanGen 5} diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} --diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6} defined RAD-Diverse-IF-MIB --ethIf OBJECT IDENTIFIER ::= {diverseIfWanGen 1} (see ethif.txt) --sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} (see radsonet.txt) --ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} (see radds3.txt) --ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} (see radds1.txt) --hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} (see radhdlc.txt) --v51If OBJECT IDENTIFIER ::= {diverseIfWanGen 6} (see v51.txt) --ip2If OBJECT IDENTIFIER ::= {diverseIfWanGen 7} (see ipmux.txt) --broadbandIf OBJECT IDENTIFIER ::= {diverseIfWanGen 8} (see bdband.txt) --r2If OBJECT IDENTIFIER ::= {diverseIfWanGen 9} (see r2.txt) --adslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 10} (see radadsl.txt) --sdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 11} (see radsdsl.txt) --shdslIf OBJECT IDENTIFIER ::= {diverseIfWanGen 12} (see radshdsl.txt) --voiceIf OBJECT IDENTIFIER ::= {diverseIfWanGen 13} (see voiceIf.txt) --gsmInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 14} (see radGsm.txt) --ds0BundleIf OBJECT IDENTIFIER ::= {diverseIfWanGen 15} (see radds0.txt) --pdhInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 16} (see radpdh.txt) --voipWanGen OBJECT IDENTIFIER ::= {wanGen 7} (see voip.txt) statAgnGen OBJECT IDENTIFIER ::= {agnWanGen 1} cnfgAgnGen OBJECT IDENTIFIER ::= {agnWanGen 2} cmprAgnGen OBJECT IDENTIFIER ::= {agnWanGen 3} alrBuffGen OBJECT IDENTIFIER ::= {agnWanGen 4} agnFlipDb OBJECT IDENTIFIER ::= {agnWanGen 5} agnSa OBJECT IDENTIFIER ::= {agnWanGen 6} agnListDecoding OBJECT IDENTIFIER ::= {agnWanGen 7} agnSystemDlci OBJECT IDENTIFIER ::= {agnWanGen 8} agnVoiceSwitching OBJECT IDENTIFIER ::= {agnWanGen 9} agnSigProfile OBJECT IDENTIFIER ::= {agnWanGen 10} agnSystemTs OBJECT IDENTIFIER ::= {agnWanGen 11} systemVoice OBJECT IDENTIFIER ::= {agnWanGen 12} statMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 1} cnfgMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 2} cmprMdlGen OBJECT IDENTIFIER ::= {mdlWanGen 3} statPrtGen OBJECT IDENTIFIER ::= {prtWanGen 1} cnfgPrtGen OBJECT IDENTIFIER ::= {prtWanGen 2} cmprPrtGen OBJECT IDENTIFIER ::= {prtWanGen 3} --statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3} - Statistics of Ports --prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1} --prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2} --prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3} --prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4} agnMux OBJECT IDENTIFIER ::= {muxHub 1} mdlMux OBJECT IDENTIFIER ::= {muxHub 2} prtMux OBJECT IDENTIFIER ::= {muxHub 3} --cnfgMdlMux OBJECT IDENTIFIER ::= {mdlMux 1} --statMdlMux OBJECT IDENTIFIER ::= {mdlMux 2} statPrtMux OBJECT IDENTIFIER ::= {prtMux 1} cnfgPrtMux OBJECT IDENTIFIER ::= {prtMux 2} statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3} prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1} prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2} prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3} prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4} -- --prtSExHsfStatTable OBJECT IDENTIFIER ::= {statPrtMux 6} --prtIsdnStatusTable OBJECT IDENTIFIER ::= {statPrtMux 16} -- prtClCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 1} prtPh1MlCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 2} --MPH1/e1/t1 prtPhPlCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 3} --MPH1,MPH3,MPL6 prtLs2Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 4} --LS2 family --prtVc2CnfgTable OBJECT IDENTIFIER ::= {cnfgPrtMux 5} --prtHsfCnfgTable OBJECT IDENTIFIER ::= {cnfgPrtMux 6} prtHs4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 7} prtHsiCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 8} prtPVc4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 9} prtHsrCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 10} prtMbeCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 11} prtTreCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 12} prtLs6Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 13} prtVc3Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 14} prtVcPbxCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 15} prtIsdnCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 16} prtLogicalCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 17} prtFrPlusCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 18} prtMl4Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 19} prtAcmCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 20} prtE2Cnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 21} prtLanWanCnfg OBJECT IDENTIFIER ::= {cnfgPrtMux 22} -- -- Wan chassis general information -- chasVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "An ASCII string for description and display of the agent chassis version." ::= { chasWanGen 1 } chasTotalNoOfSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the number of physical slots in the chassis." ::= { chasWanGen 2 } chasTotalNoOfIoSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the total number of physical IO slots in the chassis, (not all slots hardware should be occupied and active) ." ::= { chasWanGen 3 } chasTotalNoOfPsSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the number of physical Power Supply slots in the chassis." ::= { chasWanGen 4 } chasTotalNoOfClSlt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the number of physical Common Logic slots in the chassis." ::= { chasWanGen 5 } -- -- Wan agent status general information -- agnSDateFormat OBJECT-TYPE SYNTAX INTEGER { ddMMYYYY (1), mmDDYYYY (2), yyyyDDMM (3), yyyyMMDD (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the date and time format used for the agnSDateAndTimeCmd and for the alarm history report." ::= { statAgnGen 1 } agnSDateCmd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the current date as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. This parameter can be set for time synchronization between the NMS and the Agent." ::= { statAgnGen 2 } agnSTimeCmd OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This entry indicates the current time as it is known by the agent using its own real-time clock. This parameter can be set for time synchronization between the NMS and the Agent." ::= { statAgnGen 3 } agnSActiveCnfg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry specifies the unique identifier of the configuration, that is currently active and running." ::= { statAgnGen 4 } -- return 1 (db1) in phase I agnSEditCnfg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the unique identifier of the configuration that is currently loaded into the tmp working space for manipulation and update operations. Value of 255 means no config. is under editing process." ::= { statAgnGen 5 } -- return 1 (db1) in phase I agnSLastCnfgFlipTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the Date & Time of the last flip to the current configuration at the agent." ::= { statAgnGen 6 } -- return sysUpTime in phase I agnSLastCnfgFlipCause OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry describes the flip's cause." ::= { statAgnGen 7 } -- In phase I return two causes: -- Power up -- Update Db agnSEditBy OBJECT-TYPE SYNTAX INTEGER { none (1), snmp (2), terCon1 (3), terCon2 (4), terInbandCon1 (5), terInbandCon2 (6), lcd (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates which MMI application is working on the edited config. The editing phase starts at the first modify operation and ends after an update(load) operation." ::= { statAgnGen 8 } agnSClkSrc OBJECT-TYPE SYNTAX INTEGER { master (1), fallback(2), internal(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the source of the system clock." ::= { statAgnGen 9 } agnSAlrStatus OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the agent level, i.e. lower level (card/port) alarms not included. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { statAgnGen 10 } agnSAlrStatusAll OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state of the entire agent, i.e. including card and port alarms status. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { statAgnGen 11 } agnSMaskedAlrStat OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the agent level,[ i.e. lower level (card/port) alarms not included] including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { statAgnGen 12 } agnSMaskedAlrStatAll OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state of the entire agent, i.e. including card and port alarms status,including Masked alarms. critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { statAgnGen 13 } agnSTstStatAll OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "on(3) - when there is at least one test in progress in one of the agent cards, otherwise the value will be off(2)." ::= { statAgnGen 14 } agnSAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of agent related alarms and indications for alarms at system level." ::= { statAgnGen 15 } agnSAlrEntry OBJECT-TYPE SYNTAX AgnSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnSAlrIdx} ::= { agnSAlrTable 1} AgnSAlrEntry ::= SEQUENCE { agnSAlrIdx Integer32, agnSAlrCodeDescription DisplayString, agnSAlrCode Integer32, agnSAlrSeverity INTEGER, agnSAlrState INTEGER, agnSAlrCounter Integer32, agnSAlrMask INTEGER, agnSAlrInvert INTEGER } agnSAlrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table of the agent." ::= { agnSAlrEntry 1 } agnSAlrCodeDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter." ::= { agnSAlrEntry 2 } agnSAlrCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A code identifying the alarm of an entry in the alarm status table at system level." ::= { agnSAlrEntry 3 } agnSAlrSeverity OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the alarm." ::= { agnSAlrEntry 4 } agnSAlrState OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the alarm." ::= { agnSAlrEntry 5 } agnSAlrCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately." ::= { agnSAlrEntry 6 } agnSAlrMask OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm mask : on/off." ::= { agnSAlrEntry 7 } agnSAlrInvert OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm invert : on/off." ::= { agnSAlrEntry 8 } agnSClearAlrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, enforce a clear operation on all the agent(general) events. General alarms are alarms which are not specific to a card or port. The clear operation will not be applied for masked/inverted alarms." ::= { statAgnGen 16 } agnSClearAllAlrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, enforce a clear operation on all MUX alarm events at the levels of agent, slots and ports. The clear operation will not be applied for masked/inverted alarms." ::= { statAgnGen 17 } agnSSanityCheckStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), fail (2), warning (3), ok (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Upon completion of the Sanity check process on the TmpCnfg this attribute will be set to: FAIL(2) - when there is at least one error encountered and possibly some warnings. WARNING(3) - when there are only warnings. otherwise, the value will be OK(4). The value will be UNKNOWN(1) if changes were made in the TmpCnfg following the last Sanity check." ::= { statAgnGen 18 } agnSNoOfSanityCheckErr OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This entry indicates the number of errors/warnings discovered by the last SanityCheck process." ::= { statAgnGen 19 } agnSErrListTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSErrListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of errors and warnings found during Sanity Check process." ::= { statAgnGen 20 } agnSErrListEntry OBJECT-TYPE SYNTAX AgnSErrListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnSErrIdx} ::= { agnSErrListTable 1} AgnSErrListEntry ::= SEQUENCE { agnSErrIdx Integer32, agnSErrDescription DisplayString } agnSErrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify an entry in the error list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'. " ::= { agnSErrListEntry 1} agnSErrDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a full text description of the sanity check error including error code, slot and port numbers related to the code ." ::= { agnSErrListEntry 2} agnSMaxNoOfCnfg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum number of configurations that can be defined and stored in the MUX. If the mux has a large capacity, the maximum will be limited to 254." ::= { statAgnGen 21} -- return 1 (db1) in phase I agnSCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains an entry per configuration. It indicates if the configuration is valid." ::= { statAgnGen 22 } -- - in phase I only one entry agnSCnfgEntry OBJECT-TYPE SYNTAX AgnSCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnSEntryIdx} ::= {agnSCnfgTable 1} AgnSCnfgEntry ::= SEQUENCE { agnSEntryIdx Integer32, agnSEntryIsValid INTEGER } agnSEntryIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify an entry in the configuration table." ::= { agnSCnfgEntry 1} agnSEntryIsValid OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates whether the specific configuration is valid in the MUX . Value of NO indicates: no such configuration in the MUX. " ::= { agnSCnfgEntry 2} -- -- Wan agent configuration information -- agnCSanityCheckCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on(3) will initiate the process of Sanity check on the TmpCnfg. Upon completion the value will automatically be changed to off(2)." ::= { cnfgAgnGen 1 } agnCSaveCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute specifies the Id of the target RealCnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown" ::= { cnfgAgnGen 2 } -- In phase I only the value 1 (Cnfg1) is valid. agnCLoadCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute specifies the Id of the source Cnfg to be loaded into the TmpCnfg. Upon set operation the actual transfer will be initiated. The operation is valid only on Valid configurations (agnSEntryIsValid)" ::= { cnfgAgnGen 3 } -- In phase I only the value 1 (Cnfg1) is valid. agnCClkSrcTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCClkSrcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All the entries of this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only for the TmpCnfg entry." ::= { cnfgAgnGen 4} agnCClkSrcEntry OBJECT-TYPE SYNTAX AgnCClkSrcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCClkCnfgIdx, agnCClkSrcIdx} ::= { agnCClkSrcTable 1} AgnCClkSrcEntry ::= SEQUENCE { agnCClkCnfgIdx Integer32, agnCClkSrcIdx Integer32, agnCClkSrcMode INTEGER, agnCClkSrcSlt INTEGER, agnCClkSrcPrt Integer32 } agnCClkCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..100) being accessed and Idx 255 relates to the TmpCnfg." ::= { agnCClkSrcEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. agnCClkSrcIdx OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "An index to the table. There are only two entries to this table. Index 1 points to the Master clock parameters and Index 2 points to the Fallback clock parameters" ::= { agnCClkSrcEntry 2} agnCClkSrcMode OBJECT-TYPE SYNTAX INTEGER { internal (1), rxClk (2), adaptive (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The source of the nodal timing." ::= { agnCClkSrcEntry 3} agnCClkSrcSlt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is valid only when we are working in rxClk mode. For an invalid entry, the return value will be '7fff'h." ::= { agnCClkSrcEntry 4} agnCClkSrcPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is valid only when we are working in rxClk or adaptive mode. For an invalid entry, the return value will be '7fff'h. - For rxClk mode, the values can be: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , notApplicable (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) - For adaptive mode, the value will be the ifIndex of the selected IP Bundle." ::= { agnCClkSrcEntry 5} agnCDeleteCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute will delete the requested DB from the NVRAM ." ::= { cnfgAgnGen 5 } agnCDefaultCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..100) MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute will define the desired working configuration when no conditions of the Flip DB Table are fulfilled and no Net GO command was issued. This command will be accepted only if the Configuration number exists (agnSEntryIsValid=yes)." ::= { cnfgAgnGen 6 } agnCnfgDataTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCnfgDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains data about the agent configurations. The table will support only data about valid configurations of the agent." ::= { cnfgAgnGen 7} agnCnfgDataEntry OBJECT-TYPE SYNTAX AgnCnfgDataEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCnfgIdx} ::= { agnCnfgDataTable 1} AgnCnfgDataEntry ::= SEQUENCE { agnCnfgIdx Integer32, agnCnfgDesc DisplayString, agnCnfgUpdDate DisplayString, agnCnfgUpdTime DisplayString, agnCnfgUpdMnger IpAddress } agnCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the agent' Cnfg the following objects refer. 255=Temporary Cnfg (Set is done only to this configuration)." ::= { agnCnfgDataEntry 1} -- Only the values 1..10, 255 are valid. agnCnfgDesc OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is a description of the Configuration, entered by user, to enhance Cnfg recognition." ::= { agnCnfgDataEntry 2} agnCnfgUpdDate OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the date when last update of this configuration was performed, as it is known by the agent using its own real-time clock. The format would be as specified by the agnSDateFormat. When update is performed, the agent should save the date." ::= { agnCnfgDataEntry 3 } agnCnfgUpdTime OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the time when last update of this configuration was performed, as it is known by the agent using its own real-time clock. When update is performed, the agent should save the time." ::= { agnCnfgDataEntry 4 } agnCnfgUpdMnger OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the IP Address of the Manager who performed the last update of this configuration. When update is performed, the agent should save the IP Address of the Manager who commanded the update. That will enable a manager to know if he performed the last update, or another manager did." ::= { agnCnfgDataEntry 5 } agnCnfgAlarm OBJECT IDENTIFIER ::= { cnfgAgnGen 8} agnCnfgAlrFilterWindow OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Window of time, in seconds. During this Window, the alarms filter is performed. Same Window for all agent alarms that need filtering. Upon end of the Window, the state of the alarm is updated and a new Window starts. If no alarm needs filtering, this object's value will not be used." ::= { agnCnfgAlarm 1} agnCnfgAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCnfgAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table enables the user to set attributes to each alarm. Setting for a non-existing entry agnCnfgAlrMask, agnCnfgAlrInvert or agnCnfgAlrFilter to 'yes'(or yesAndSave for Mask) will add this new entry to the table. Setting for an existing entry agnCnfgAlrMask/ agnCnfgAlrInvert/agnCnfgAlrFilter (one or more) to 'no' (noAndSave for Mask) so that ALL these objects' values are 'no' , will delete this entry from the table. For agnCnfgAlrMask, only if [(last saved value=noAndSave) AND (new value is 'no' or 'noAndSave')] the object's value is considered 'no' for deleting the entry. For some products (like MP, MPH, Vmux2100) the Active Alarms are always part of the table and cannot be removed even if their Mask/Invert/Filter are No." ::= { agnCnfgAlarm 2} agnCnfgAlrEntry OBJECT-TYPE SYNTAX AgnCnfgAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCnfgAlrCode, agnCnfgAlrSlot, agnCnfgAlrPort} ::= { agnCnfgAlrTable 1} AgnCnfgAlrEntry ::= SEQUENCE { agnCnfgAlrCode Integer32, agnCnfgAlrSlot INTEGER, agnCnfgAlrPort Integer32, agnCnfgAlrMask INTEGER, agnCnfgAlrInvert INTEGER, agnCnfgAlrFilter INTEGER, agnCnfgAlrFilterSet Integer32, agnCnfgAlrFilterReset Integer32, agnCnfgAlrSeverity INTEGER } agnCnfgAlrCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm code. The following attributes refer this code." ::= { agnCnfgAlrEntry 1 } agnCnfgAlrSlot OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), all (200), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm slot. The following attributes apply for the alarm code and slot selected. all = the attributes apply to all slots. notApplicable = the selected alarm is for system level. For the Vmux2100 Main Board clA (3) is used." ::= { agnCnfgAlrEntry 2 } agnCnfgAlrPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm port. The following attributes apply for the alarm code,slot and port selected. 200 = all = the attributes apply to all ports of the selected slot. When selected Slot is 'all', only 'all' or 'notApplicable' are valid Port selections. notApplicable = the selected alarm is for system or card level. =255 for MP =100 for DXC - For MP: - valid cards' ports are: exPrt1(1)..exPrt16(16) inPrt1(101)..inPrt48 (148) - IP Bundles - For DXC, the port index will include the Slot, as for all DXC tables: [(IO Slot+10)&n] ; n=odd for external ports n=even for internal ports." ::= { agnCnfgAlrEntry 3 } agnCnfgAlrMask OBJECT-TYPE SYNTAX INTEGER { no (1), noAndSave (2), yes (3), yesAndSave (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "An attribute defining the desired Mask state of an alarm . no - unmask (this command is not saved in agent's common database) noAndSave - unmask ; this command is saved in agent's common database yes - mask (this command is not saved in agent's common database) yesAndSave - mask ; this command is saved in agent's common database. Commands that are not saved, will be lost upon power-up or selected card removal. " ::= { agnCnfgAlrEntry 4 } agnCnfgAlrInvert OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "An attribute defining the desired Invert state of an alarm . no - not inverted. yes - inverted. For MP, it is not applicable for alarms that are currently OFF." ::= { agnCnfgAlrEntry 5 } agnCnfgAlrFilter OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "An attribute defining if Filter is desired for the alarm . no - no filter. yes - filter activate. This filter is activated within a window of time defined by agnCnfgAlrFilterWindow. Its purpose is to avoid frequent changes of an alarm between ON/OFF states." ::= { agnCnfgAlrEntry 6 } agnCnfgAlrFilterSet OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a top threshold causing the alarm that passes it, to be declared Set (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at least, during the window in order to be considered ON. The maximum value will be 255. This value should be greater than the one of agnCnfgAlrFilterReset. Agents that do not support Alarms Filter, will return 0." ::= { agnCnfgAlrEntry 7 } agnCnfgAlrFilterReset OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is a bottom threshold causing the alarm that does not pass it, to be declared Reset (ON) at the end of the respective window of time. - For alarms defined by default as state alarms (minor,major) this value will be in [%]. - For alarms defined by default as events, this value will be an integer meaning how many times this event should appear at most, during the window, in order to be considered OFF. This value should be less than the one of agnCnfgAlrFilterSet. Agents that do not support Alarms Filter, will return 0." ::= { agnCnfgAlrEntry 8 } agnCnfgAlrSeverity OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "An attribute defining desired severity of an alarm code per slot/port " ::= { agnCnfgAlrEntry 9 } agnCnfgAlrReportTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCnfgAlrReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table enables the user to configure the desired Alarm Reports according to alarms severity." ::= { agnCnfgAlarm 3} agnCnfgAlrReportEntry OBJECT-TYPE SYNTAX AgnCnfgAlrReportEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCnfgAlrReportType} ::= { agnCnfgAlrReportTable 1} AgnCnfgAlrReportEntry ::= SEQUENCE { agnCnfgAlrReportType INTEGER, agnCnfgAlrStartReportOn INTEGER, agnCnfgAlrStartReportOff INTEGER } agnCnfgAlrReportType OBJECT-TYPE SYNTAX INTEGER { trap (1), buffer (2), relay (3), --Relay 1 = R1 alrLedOn (4), --Minor LED alrLedBlink (5), --Major LED relay2 (6) --Relay 2 = R2 } MAX-ACCESS read-only STATUS current DESCRIPTION "The alarm report type. trap - traps will be sent only for alarms having the selected On/Off severity or higher. buffer - only alarms having the selected On/Off severity and higher, will be reported to the buffer. relay - relay contact will be activated only for alarms having the selected On severity or higher. For products having 2 relays, this is the R1 Relay. alrLedOn/alrLedBlink - user should select a higher severity (ReportOn) for alrLedBlink than for alrLedOn (Blinking Led means a more severe alarm than steady ON Led). alrLedOn - MTCL-1 Alarm Led will be ON only when agnSAlrStatusAll equals the selected severity or higher, but lower severity than that selected for 'alrLedBlink'. For products having 2 LEDs, this is the Minor LED. alrLedBlink - MTCL-1 Alarm Led will Blink only when agnSAlrStatusAll equals the selected severity or higher. For products having 2 LEDs, this is the Major LED. relay2 - relay 2 contact will be activated only for alarms having the selected On severity or higher. This is the R2 Relay." ::= { agnCnfgAlrReportEntry 1 } agnCnfgAlrStartReportOn OBJECT-TYPE SYNTAX INTEGER { noReport (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to ON state. noReport - no Report at all (for any severity)." ::= { agnCnfgAlrReportEntry 2 } agnCnfgAlrStartReportOff OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), noReport (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the severity from which alarms will be reported. Alarms having this severity or higher, will be reported. This object specifies the report severity only for alarms that turn to OFF state. notApplicable - for 'relay','alrLedOn','alrLedBlink', 'relay2' report types, in MP. noReport - no Report at all (for any severity)." ::= { agnCnfgAlrReportEntry 3 } agnCOffsetCmd OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), normal (2), u1 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "An object defining special user request. notApplicable - is RO value for products that do not support this object. normal - nothing special u1 - user 1 - for all Voice cards, the DISPLAYED Tx and Rx Levels will have the following Offsets: - 2 Wires port: Tx Level: the base value (for 0dBm) = 0 Rx Level: the base value (for 0dBm) = -2 - 4 Wires port: Tx Level: the base value (for 0dBm) = -16 Rx Level: the base value (for 0dBm) = 7 The MIB and application DB will use the values without Offset." ::= { cnfgAgnGen 9 } --System T1/E1 Ring Table -- --This table contains all ML ports that participate in a T1/E1 Ring, --and their ML port pair. --The table indexes are Cnfg and the Primary card & port agnCT1E1RingTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCT1E1RingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration of all T1/E1 Ring ML cards and ports. The write operation into the table objects is valid only for the TmpCnfg. A Slot/Port that does not participate in the T1/E1 Ring, will not exist in this table. A ML port that exists in this table, cannot exist at the same time in the IO Redundancy table (sysCRdnTable)." ::= { cnfgAgnGen 10 } agnCT1E1RingEntry OBJECT-TYPE SYNTAX AgnCT1E1RingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry in table agnCT1E1RingTable" INDEX { agnCT1E1RingCnfgIdx, agnCT1E1RingPrimeSlot, agnCT1E1RingPrimePort} ::= { agnCT1E1RingTable 1} AgnCT1E1RingEntry ::= SEQUENCE { agnCT1E1RingCnfgIdx Integer32, agnCT1E1RingPrimeSlot INTEGER, agnCT1E1RingPrimePort Integer32, agnCT1E1RingSecSlot INTEGER, agnCT1E1RingSecPort Integer32, agnCT1E1RingRecTime Integer32, agnCT1E1RingRowStatus RowStatus, agnCT1E1RingWTR Unsigned32, agnCT1E1RingDualFailDetection INTEGER } agnCT1E1RingCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg(1..255) being accessed ; Idx of 255 relates to the TmpCnfg." ::= { agnCT1E1RingEntry 1 } agnCT1E1RingPrimeSlot OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number of the Primary card of the Ring Pair." ::= { agnCT1E1RingEntry 2 } agnCT1E1RingPrimePort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The port number in the Primary Card. For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 " ::= { agnCT1E1RingEntry 3 } agnCT1E1RingSecSlot OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-create STATUS current DESCRIPTION "The slot number of the Secondary card of the Ring Pair." ::= { agnCT1E1RingEntry 4 } agnCT1E1RingSecPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The port number in the Secondary Card. For external ports, the value will be as that of the port in the card. Example: external-3 -> 3 external-4 -> 4 For internal ports, the value will be 100 + the port in the card. Example: internal-1 -> 101 internal-4 -> 104 " ::= { agnCT1E1RingEntry 5 } agnCT1E1RingRecTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "T1/E1 Ring Recovery Time (sec). Valid Values: 1..99, 65535. 65535=NA." ::= { agnCT1E1RingEntry 6 } agnCT1E1RingRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter allows NMS to create/delete entries of this table. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { agnCT1E1RingEntry 7 } agnCT1E1RingWTR OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "T1/E1 Ring Wait to Restore (sec). Valid Values: 0..999, 65535. 65535=NA. When the value <> 65535, the value of agnCT1E1RingRecTime must be 65535." ::= { agnCT1E1RingEntry 8 } agnCT1E1RingDualFailDetection OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "T1/E1 Ring - Dual Failure Detection enable/disable." ::= { agnCT1E1RingEntry 9 } agnCMainExitPort OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), eth (2), e1T1SerialLink (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "An object defining the Main Exit Port for the Data of the device. In the Vmux-120 Device the Data can Exit via one of the 2 existing ports: 1. Ethernet port (2) 2. A port that can be E1 or T1 or a Serial Link (3)." ::= { cnfgAgnGen 11 } -- Backup Configuration Table for Main Link Module agnCBuMlTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCBuMlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Configuration for Primary, Secondary and Third Link. These are used for Link Backup." ::= { cnfgAgnGen 12 } agnCBuMlEntry OBJECT-TYPE SYNTAX AgnCBuMlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry in table agnCBuMlTable" INDEX { agnCBuMlCnfgIdx, agnCBuMlRole} ::= { agnCBuMlTable 1} AgnCBuMlEntry ::= SEQUENCE { agnCBuMlCnfgIdx Integer32, agnCBuMlRole INTEGER, agnCBuMlType INTEGER, agnCBuMlDefaultGateway IpAddress, agnCBuMlSubnetMask IpAddress, agnCBuMlOamFrequency Integer32, agnCBuMlOamTimeoutCycles Integer32, agnCBuMlWaitToRestore Unsigned32, agnCBuMlBfdSessionNum Unsigned32 } agnCBuMlCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the Index of the Configuration database (1..255) being accessed. Index of 255 relates to the Temporary Configuration." ::= { agnCBuMlEntry 1 } agnCBuMlRole OBJECT-TYPE SYNTAX INTEGER { primary (2), secondary (3), third (4), fourth (5) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Role of the Link. Primary Link is the Link that should usually work. If the Primary Link fails, the data will go through the Secondary Link. If both Primary and Secondary Links fail, the data will go through the Third Link, provided it is up." ::= { agnCBuMlEntry 2 } agnCBuMlType OBJECT-TYPE SYNTAX INTEGER { none (2), e1T1a (3), e1T1b (4), eth (5), ethNetUser (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Type of the Link. For E1/T1 the Link can be Link A - e1T1a or Link B - e1T1b. For ETH-NET, eth (5) can be used. For ETH-NET/USER ethNetUser (6) can be used." ::= { agnCBuMlEntry 3 } agnCBuMlDefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Default Gateway's IP Address." ::= { agnCBuMlEntry 4 } agnCBuMlSubnetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The Link subnet mask." ::= { agnCBuMlEntry 5 } agnCBuMlOamFrequency OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Time in sec. between 2 OAM packets." ::= { agnCBuMlEntry 6 } agnCBuMlOamTimeoutCycles OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "No. of cycles the Link will send OAM packets without receiving a response from the remote Link before switching to the Backup Link." ::= { agnCBuMlEntry 7 } agnCBuMlWaitToRestore OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines traffic recovery time (in milliseconds) of the link after its recovery. This object is applicable only when Recovery Mode is revertive." ::= { agnCBuMlEntry 8 } agnCBuMlBfdSessionNum OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the BFD (Bidirectional Forwarding Detection) session number of the link. When no session exists or when N/A, the value will be 0." ::= { agnCBuMlEntry 9 } agnCQ50Table OBJECT-TYPE SYNTAX SEQUENCE OF AgnCQ50Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table for the device Q50 parameters. Q50 is a Signaling protocol used between PBX devices. It is possible to control the initiation of calls using Q.50. This is useful for devices when there is a congestion." ::= { cnfgAgnGen 13 } agnCQ50Entry OBJECT-TYPE SYNTAX AgnCQ50Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An Entry in table agnCQ50Table" INDEX { agnCQ50CnfgIdx} ::= { agnCQ50Table 1} AgnCQ50Entry ::= SEQUENCE { agnCQ50CnfgIdx Integer32, agnCQ50StopCallsThresh Integer32, agnCQ50DiscardPktThresh Integer32, agnCQ50BlockNewModemVbdCallsThresh Integer32, agnCQ50BlockNewModemRelayCallsThresh Integer32 } agnCQ50CnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the Index of the Configuration database (1..255) being accessed. Index of 255 relates to the Temporary Configuration." ::= { agnCQ50Entry 1 } agnCQ50StopCallsThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Bandwidth Threshold percent (%) above which new Calls from the PBX will be disabled." ::= { agnCQ50Entry 2 } agnCQ50DiscardPktThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Bandwidth Threshold percent (%) above which voice packets will be discarded. Usually, the value selected should be higher than the value of agnCQ50StopCallsThresh." ::= { agnCQ50Entry 3 } agnCQ50BlockNewModemVbdCallsThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Modem VBD Calls Threshold percent (%) above which new modem calls will be rejected." ::= { agnCQ50Entry 4 } agnCQ50BlockNewModemRelayCallsThresh OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Modem Relay Calls Threshold percent (%) above which new modem calls will be rejected." ::= { agnCQ50Entry 5 } -- -- Compressed information. -- -- Specially for RadView management station -- agnCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprAgnGen 1 } agnCmprEntry OBJECT-TYPE SYNTAX AgnCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnCmprTypIdx, agnCmprCnfgIdx ,agnCmprVersion} ::= {agnCmprTable 1} AgnCmprEntry ::= SEQUENCE { agnCmprTypIdx Integer32, agnCmprCnfgIdx Integer32, agnCmprVersion Integer32, agnCmprObj OCTET STRING } agnCmprTypIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Type of the Compressed being referred." ::= { agnCmprEntry 1} agnCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the configuration to which the Compressed information is related." ::= { agnCmprEntry 2} agnCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { agnCmprEntry 3} agnCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { agnCmprEntry 4} -- Compressed Dlci table in the Agent level -- The only way of reading this table is by the command 'GET NEXT' agnDlciCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnDlciCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {cmprAgnGen 2} agnDlciCmprEntry OBJECT-TYPE SYNTAX AgnDlciCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnDlciCmprCnfgIdx,agnDlciCmprVersion,agnDlciCmprDlciIdx} ::= {agnDlciCmprTable 1} AgnDlciCmprEntry ::= SEQUENCE { agnDlciCmprCnfgIdx Integer32, agnDlciCmprVersion Integer32, agnDlciCmprDlciIdx Integer32, agnDlciCmprObj OCTET STRING } agnDlciCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the configuration to which the Compressed information is related." ::= { agnDlciCmprEntry 1} agnDlciCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { agnDlciCmprEntry 2} agnDlciCmprDlciIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the Dlci, the compressed information relates to. The values are between 16 - 991." ::= { agnDlciCmprEntry 3} agnDlciCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { agnDlciCmprEntry 4} -- Compressed Status Alarm table at the Agent level -- The only way of reading this table is by the command 'GET NEXT' agnAlarmsCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {cmprAgnGen 3} agnAlarmsCmprEntry OBJECT-TYPE SYNTAX AgnAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnAlarmsCmprVersion,agnAlarmsCmprAlarmIdx} ::= {agnAlarmsCmprTable 1} AgnAlarmsCmprEntry ::= SEQUENCE { agnAlarmsCmprVersion Integer32, agnAlarmsCmprAlarmIdx Integer32, agnAlarmsCmprObj OCTET STRING } agnAlarmsCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { agnAlarmsCmprEntry 1} agnAlarmsCmprAlarmIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table of the agent." ::= { agnAlarmsCmprEntry 2} agnAlarmsCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { agnAlarmsCmprEntry 3} -- Compressed History Alarms buffer -- The only way of reading this table is by the command 'GET NEXT' agnAlrBufCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnAlrBufCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {cmprAgnGen 4} agnAlrBufCmprEntry OBJECT-TYPE SYNTAX AgnAlrBufCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnAlrBufCmprVersion,agnAlrBufCmprAlarmIdx} ::= {agnAlrBufCmprTable 1} AgnAlrBufCmprEntry ::= SEQUENCE { agnAlrBufCmprVersion Integer32, agnAlrBufCmprAlarmIdx Integer32, agnAlrBufCmprObj OCTET STRING } agnAlrBufCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { agnAlrBufCmprEntry 1} agnAlrBufCmprAlarmIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the history alarms buffer of the agent." ::= { agnAlrBufCmprEntry 2} agnAlrBufCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { agnAlrBufCmprEntry 3} -- Compressed Sanity Errors buffer -- The only way of reading this table is by the command 'GET NEXT' agnSCmprErrListTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSCmprErrListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprAgnGen 5 } agnSCmprErrListEntry OBJECT-TYPE SYNTAX AgnSCmprErrListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnSCmprErrVersion,agnSCmprErrIdx} ::= { agnSCmprErrListTable 1} AgnSCmprErrListEntry ::= SEQUENCE { agnSCmprErrVersion Integer32, agnSCmprErrIdx Integer32, agnSCmprErrObj OCTET STRING } agnSCmprErrVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The version of the compressed data " ::= { agnSCmprErrListEntry 1} agnSCmprErrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Unique number to identify an entry in the errors list table. The maximum entry value cannot exceed the value of 'agnSNoOfSanityCheckErr'. " ::= { agnSCmprErrListEntry 2} agnSCmprErrObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a full text description of the error, including: error code, slot and port numbers related to the code ." ::= { agnSCmprErrListEntry 3} -- New TS Assignment compressed table, per port 01/09/98 -- The only way of reading this table is by the command 'GET NEXT' agnTsCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnTsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprAgnGen 6 } agnTsCmprEntry OBJECT-TYPE SYNTAX AgnTsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnTsCmprVerIdx, agnTsCmprCnfgIdx , agnTsCmprSlotIdx, agnTsCmprPortIdx, agnTsCmprPduIdx } ::= {agnTsCmprTable 1} AgnTsCmprEntry ::= SEQUENCE { agnTsCmprVerIdx Integer32, agnTsCmprCnfgIdx Integer32, agnTsCmprSlotIdx Integer32, agnTsCmprPortIdx Integer32, agnTsCmprPduIdx Integer32, agnTsCmprData OCTET STRING } agnTsCmprVerIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the version of the internal format of the Compressed data." ::= { agnTsCmprEntry 1} agnTsCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration." ::= { agnTsCmprEntry 2} agnTsCmprSlotIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Slot to which the Compressed information is related. For MP-2100: IO-1..IO-12 = (5).. (16) For DXC-30 : IO-1..IO-15 = (5).. (19). NA=255." ::= { agnTsCmprEntry 3} agnTsCmprPortIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Port within the Slot, to which the Compressed information is related. For Port Index see each product's spec." ::= { agnTsCmprEntry 4} agnTsCmprPduIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the PDU index within the same port. That provides for the case when one PDU is not sufficient for all TS Assignment data of the same port." ::= { agnTsCmprEntry 5} agnTsCmprData OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the compressed information itself. It provides information about all TSs of a port." ::= { agnTsCmprEntry 6} -- Extended Compress General Table with 7 indexes - 10/02/99 -- Used for: V5.1 and V5.2 Variant agnXCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnXCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprAgnGen 7 } agnXCmprEntry OBJECT-TYPE SYNTAX AgnXCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnXCmprTypIdx, agnXCmprVersion, agnXCmprIdx3,agnXCmprIdx4, agnXCmprIdx5, agnXCmprIdx6, agnXCmprIdx7} ::= {agnXCmprTable 1} AgnXCmprEntry ::= SEQUENCE { agnXCmprTypIdx Integer32, agnXCmprVersion Integer32, agnXCmprIdx3 Integer32, agnXCmprIdx4 Integer32, agnXCmprIdx5 Integer32, agnXCmprIdx6 Integer32, agnXCmprIdx7 Integer32, agnXCmprObj OCTET STRING } agnXCmprTypIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Type of the Compressed being referred. One of the types is V5.1 Variant data." ::= { agnXCmprEntry 1} agnXCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data." ::= { agnXCmprEntry 2} agnXCmprIdx3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "3rd index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant, this attribute indicates the configuration to which the Compressed information is related. 255=temporary configuration. Set can be performed only to the temporary configuration." ::= { agnXCmprEntry 3} agnXCmprIdx4 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "4th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique number of the slot position where the card is inserted. Valid values: psA(1),psB(2),clA(3),clB(4),io1(5)..io12(16); notApplicable=255." ::= { agnXCmprEntry 4} agnXCmprIdx5 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "5th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt12 (12) , inPrt1 (101) .. inPrt48 (148)." ::= { agnXCmprEntry 5} agnXCmprIdx6 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "6th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute indicates the Variant index. Valid values are: 0..127, 255 (= temp cnfg).Set can be performed only to the temporary configuration." ::= { agnXCmprEntry 6} agnXCmprIdx7 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "7th index - can be used for any purpose according to the agnXCmprTypIdx. Example: for V5.1 Variant,this attribute is not needed. Therefore, its value will be always 255=notApplicable." ::= { agnXCmprEntry 7} agnXCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { agnXCmprEntry 8} -- -- Link Mapping Table for internal use -- agnLinkMapTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnLinkMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { mapWanGen 1} agnLinkMapEntry OBJECT-TYPE SYNTAX AgnLinkMapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {mapLinkId} ::= {agnLinkMapTable 1} AgnLinkMapEntry ::= SEQUENCE { mapLinkId Integer32, mapLinkSltIdx INTEGER, mapLinkPrtIdx INTEGER, mapLinkStatus INTEGER } mapLinkId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the link" ::= {agnLinkMapEntry 1} mapLinkSltIdx OBJECT-TYPE SYNTAX INTEGER { noConnect (2), clA (3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries clA(3), io6(10)..io12(16) are not valid." ::= {agnLinkMapEntry 2} mapLinkPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , noConnect (100) , inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port number. " ::= {agnLinkMapEntry 3} mapLinkStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), down(2), up(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the link between the two muxes" ::= {agnLinkMapEntry 4} -- -- diverseIfWanGen - diverse NON-DS1 interfaces of WAN products -- --sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2} (see radsonet.txt) --ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3} (see radds3.txt) --ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4} (see radds1.txt) --hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5} (see radhdlc.txt) --ip2If OBJECT IDENTIFIER ::= { diverseIfWanGen 7 } (see ipmux.txt) -- -- Wan alarm buffer (history) information -- alrBufTable OBJECT-TYPE SYNTAX SEQUENCE OF AlrBufEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { alrBuffGen 1 } alrBufEntry OBJECT-TYPE SYNTAX AlrBufEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { alrBufIdx } ::= { alrBufTable 1} AlrBufEntry ::= SEQUENCE { alrBufIdx Integer32, alrBufDescription DisplayString, alrBufCode Unsigned32, alrBufSlot INTEGER, alrBufPort Unsigned32, alrBufSeverity INTEGER, alrBufState INTEGER } alrBufIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify this entry" ::= { alrBufEntry 1} alrBufDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This entry is a unique text description of the alarm in the buffer. The alarm description includes the following information: alarm code, slot id, card type, channel id , alarm text, alarm status, masked flag and event counter" ::= { alrBufEntry 2} alrBufCode OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "A code identifying the alarm of an entry in the alarm buffer table." ::= { alrBufEntry 3 } alrBufSlot OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The slot number this alarm refers to. When the alarm refers to a system alarm, the value will be 'notApplicable(255)'." ::= { alrBufEntry 4 } alrBufPort OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The port number this alarm refers to. If the port number is irrelevant to this alarm (if it is a system/card level alarm) the value will be 9999." ::= { alrBufEntry 5 } alrBufSeverity OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the alarm." ::= { alrBufEntry 6 } alrBufState OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the alarm (On/Off)." ::= { alrBufEntry 7 } alrBufferClearCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to ON, will enforce a clear operation on the Alarms Buffer. Upon completion, the value will automatically change to off(2). For MP-2100/2200, this command will not really erase the Alarm Buffer, but is only an ACK of seeing the Buffer. It marks a pointer of the last entry's alrBufIdx, in order to allow view of new alarms entered after this pointer (alrBufIdxUponLastAck)." ::= { alrBuffGen 2 } alrBufIdxUponLastAck OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the value of alrBufIdx for the last existing entry of alrBufTable, when alrBufferClearCmd was last Set to on(3). That will enable a user to see only Alarms that entered the alrBufTable after last Set of alrBufferClearCmd, by GetNext of alrBufDescription with this index." ::= { alrBuffGen 3 } -- -- Wan Flip Data-Base parameters -- -- agnCAgendaTable : -- agnCAgendaTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCAgendaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table devides the week days into categories needed for DB flip consideration." ::= {agnFlipDb 1} agnCAgendaEntry OBJECT-TYPE SYNTAX AgnCAgendaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCAgendaCnfgIdx, agnCAgendaDayIdx} ::= {agnCAgendaTable 1} AgnCAgendaEntry ::= SEQUENCE { agnCAgendaCnfgIdx INTEGER, agnCAgendaDayIdx INTEGER, agnCAgendaDayCategory INTEGER } agnCAgendaCnfgIdx OBJECT-TYPE SYNTAX INTEGER { active (1), temporary (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Agenda Table. Both configurations can be read but only the Temporary can be written to." ::= {agnCAgendaEntry 1} agnCAgendaDayIdx OBJECT-TYPE SYNTAX INTEGER { sunday (1), monday (2), tuesday (3), wednesday (4), thursday (5), friday (6), saturday (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Day of week" ::= {agnCAgendaEntry 2} agnCAgendaDayCategory OBJECT-TYPE SYNTAX INTEGER { fullWorkday (1), partialWorkday (2), weekend (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Category of the Day " ::= {agnCAgendaEntry 3} -- agnCFlipNetEventsTable : -- agnCFlipNetEventsTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCFlipNetEventsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table holds the Net Events the MUX should trace" ::= {agnFlipDb 2} agnCFlipNetEventsEntry OBJECT-TYPE SYNTAX AgnCFlipNetEventsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCFlipNetEventsCnfgIdx, agnCFlipNetEventIdx} ::= {agnCFlipNetEventsTable 1} AgnCFlipNetEventsEntry ::= SEQUENCE { agnCFlipNetEventsCnfgIdx INTEGER, agnCFlipNetEventIdx Integer32, agnCFlipNetEventActive INTEGER, agnCFlipNetEventType INTEGER, agnCFlipNetEventNo Integer32, agnCFlipNetEventSlot INTEGER, agnCFlipNetEventPort Integer32, agnCFlipNetEventISD Integer32, agnCFlipNetEventOSD Integer32, agnCFlipNetEventDayType INTEGER, agnCFlipNetEventStartTime DisplayString, agnCFlipNetEventEndTime DisplayString } agnCFlipNetEventsCnfgIdx OBJECT-TYPE SYNTAX INTEGER { active (1), temporary (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Net Events Table. Both configurations can be read but only the Temporary can be written to." ::= {agnCFlipNetEventsEntry 1} agnCFlipNetEventIdx OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Entry within the table" ::= {agnCFlipNetEventsEntry 2} agnCFlipNetEventActive OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the entry is valid. In order to Add/Modify parameters of an entry, this object should be set to Yes. In order to delete an entry, this object should be Set to No." ::= {agnCFlipNetEventsEntry 3} agnCFlipNetEventType OBJECT-TYPE SYNTAX INTEGER { time (1), linkDown (2), congestion (3) -- MP3000 Only } MAX-ACCESS read-write STATUS current DESCRIPTION "The Net Event type " ::= {agnCFlipNetEventsEntry 4} agnCFlipNetEventNo OBJECT-TYPE SYNTAX Integer32 (1..512) MAX-ACCESS read-write STATUS current DESCRIPTION "The Net Event No. (Bit Index)" ::= {agnCFlipNetEventsEntry 5} agnCFlipNetEventSlot OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "The slot to which the net event relates . Not applicable for time event" ::= {agnCFlipNetEventsEntry 6} agnCFlipNetEventPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The port within the relevant slot. Valid values: - extPrt1(1)..exPrt16(16) - notApplicable(100) - inPrt1(101)..inPrt84(184)" ::= {agnCFlipNetEventsEntry 7} agnCFlipNetEventISD OBJECT-TYPE SYNTAX Integer32 (1..999) MAX-ACCESS read-write STATUS current DESCRIPTION "The time in seconds since the Net Event was reported as ON until it is considered as ON. Not relevant for time events." ::= {agnCFlipNetEventsEntry 8} agnCFlipNetEventOSD OBJECT-TYPE SYNTAX Integer32 (1..999) MAX-ACCESS read-write STATUS current DESCRIPTION "The time in seconds since the net event was reported as OFF until it is considered as OFF. Not relevant for time events." ::= {agnCFlipNetEventsEntry 9} agnCFlipNetEventDayType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), fullWorkday (2), partialWorkday (3), weekend (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The time event relates to all days defined in this category in the agnCAgendaTable. Applicable only for time event" ::= {agnCFlipNetEventsEntry 10} agnCFlipNetEventStartTime OBJECT-TYPE SYNTAX DisplayString (SIZE (5)) MAX-ACCESS read-write STATUS current DESCRIPTION "The time event will be activated at this time. The format is hh:mm." ::= {agnCFlipNetEventsEntry 11} agnCFlipNetEventEndTime OBJECT-TYPE SYNTAX DisplayString (SIZE (5)) MAX-ACCESS read-write STATUS current DESCRIPTION "The time event will be deactivated at this time. The format is hh:mm." ::= {agnCFlipNetEventsEntry 12} -- agnCFlipTable : -- agnCFlipTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnCFlipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DB Flip Decisions Table" ::= {agnFlipDb 3} agnCFlipEntry OBJECT-TYPE SYNTAX AgnCFlipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnCFlipCnfgIdx, agnCFlipIdx} ::= {agnCFlipTable 1} AgnCFlipEntry ::= SEQUENCE { agnCFlipCnfgIdx INTEGER, agnCFlipIdx Integer32, agnCFlipActive INTEGER, agnCFlipLogicalExp DisplayString, agnCFlipDbNo Integer32, agnCFlipDiscardDe INTEGER } agnCFlipCnfgIdx OBJECT-TYPE SYNTAX INTEGER { active (1), temporary (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Flip Decisions Table. Both configurations can be read but only the Temporary can be written to." ::= {agnCFlipEntry 1} agnCFlipIdx OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Entry number within the table" ::= {agnCFlipEntry 2} agnCFlipActive OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if the entry is valid. In order to Add/Modify parameters of an entry this object should be Set to Yes. In order to delete an entry, this object should be Set to No." ::= {agnCFlipEntry 3} agnCFlipLogicalExp OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "A logical expression composed of events numbers (which were configured in the 'AgnCFlipNetEvantsTable') and logical operators ('|', '&', '!', '(', ')') between them. e.g - (1 & !2) | (121 & 230)" ::= {agnCFlipEntry 4} agnCFlipDbNo OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "The ID of the required DB " ::= {agnCFlipEntry 5} agnCFlipDiscardDe OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates whether the Mux should start discarding all DE. (MP3000 Only)." ::= {agnCFlipEntry 6} -- Commands concerning the Flip DB agnFlipDbControls OBJECT IDENTIFIER ::= {agnFlipDb 4} agnCFlipDbSanityCheckCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and automatically be changed to off(2)." ::= { agnFlipDbControls 1 } agnCSaveFlipDbCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on(3) will initiate the process of Sanity check on the Temp Flip Db and if it is OK, it will save the Flip Db in the NVRAM, activating the new Flip DB . If check detects errors, the save will not be performed. Afterwards, the object's value will change automatically to off(2)." ::= { agnFlipDbControls 2 } agnCSaveNetCnfgIdxCmd OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute specifies the Id of the target NVRAM Cnfg to which the TmpCnfg should be transferred. Upon set command the MUX will initiate the Sanity-Check process first. If successful, the actual transfer will be performed. If warnings are detected, the user will have to perform the command again to confirm the operation. Setting this object a second time to the same value without performing any change in the database, will cause the result: agnSSanityCheckStatus = unknown. This attribute doesn't cause actual Flip." ::= { agnFlipDbControls 3 } agnCSaveNetFlipDbCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on(3) will save the Temp Flip DB Into the NVRAM without actual flip." ::= { agnFlipDbControls 4 } agnCNetGoCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to On will broadcast a 'GO' command to the network. When a Mux receives a 'GO' command it issues a delay for 'agnCNetDelay' seconds and then activates the DB which was pre-defined by one of the commands : 'agnCSaveNetCnfgIdxCmd' or 'agnCSaveNetFlipDbCmd'." ::= { agnFlipDbControls 5 } agnCNetDelay OBJECT-TYPE SYNTAX Integer32 (1..999) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute determines the period of time in seconds that takes for a message to be transferred over all the network. After a 'GO' command the MUX issues a delay of 'agnCNetDelay' before activating the appropriate DB. The delay will be applied only after performing agnCSaveFlipDbCmd." ::= { agnFlipDbControls 6 } agnCNetEventsBcast OBJECT-TYPE SYNTAX INTEGER { disabled(2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines if the Net Events will be Broadcasted to other Muxes of the Net or not. disabled - Net Events will NOT be Broadcasted enabled - Net Events will be Broadcasted. Default=disabled. The value will be applied only after performing agnCSaveFlipDbCmd." ::= { agnFlipDbControls 7 } agnCNetEventsBcastInterval OBJECT-TYPE SYNTAX Integer32 (10..60) MAX-ACCESS read-write STATUS current DESCRIPTION "When agnCNetEventsBcast is enabled, this object determines the interval of time in seconds, between two consecutive Net Events transferred over the network. Default=40 sec. The interval will be applied only after performing agnCSaveFlipDbCmd." ::= { agnFlipDbControls 8 } -- -- agnSa = agent Stand-Alone (not HUB) specific objects -- agnSaSwchStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the status of the switches on the stand-alone unit. Each switch is represented by a bit. The status is a sum of 2**n, according to the bits: bit 0 NMS (LSB) bit 1 Terminal '1' = forces the DCE to be terminal with Rate=9600bps, Data bits=8, Stop bits=1 bit 2 Xray bit 3 SW-Load '1' = when SW is loaded bit 4 DBS Default of all bits=0 When the status of these switches is unknown, the value of this object is 255." ::= { agnSa 1 } --Decoding Table: Code vs. Description agnListDecodingTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnListDecodingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A decoding table . For each type of list, a description is given for each existing code." ::= { agnListDecoding 1 } agnListDecodingEntry OBJECT-TYPE SYNTAX AgnListDecodingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnListDecodingType, agnListDecodingCode } ::= { agnListDecodingTable 1} AgnListDecodingEntry ::= SEQUENCE { agnListDecodingType INTEGER, agnListDecodingCode Integer32, agnListDecodingDescription DisplayString, agnListDecodingDefState INTEGER, agnListDecodingSeverity INTEGER, agnListDecodingAcmRelaySlt INTEGER, agnListDecodingAcmRelayPrt INTEGER } agnListDecodingType OBJECT-TYPE SYNTAX INTEGER { alr (1), sanity (2), counter (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The type of list the decoding data refers to. alr - Alarms list sanity - Sanity Check Error list. counter - Counter type of ifPerfCounterType " ::= { agnListDecodingEntry 1} agnListDecodingCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The specific code for which decoding is needed. " ::= { agnListDecodingEntry 2} agnListDecodingDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "The description fitting the specific code and type of list required. " ::= { agnListDecodingEntry 3} agnListDecodingDefState OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object is applicable only for agnListDecodingType=alr. It reports the default state/severity of each alarm. User can change the severity of the alarms defined by this default via the agnListDecodingSeverity object." ::= { agnListDecodingEntry 4} agnListDecodingSeverity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only for agnListDecodingType=alr. It enables the user to select a severity for each alarm. The severity is set per alarm code (same for all slots/ports using this code). event - can be set only for an alarm that is defined by default as 'event'. User can change the severity of the alarms defined by default as minor or major. The severity of an event may be set to another severity, but the change will actually happen only if the event threshold is active and passed the Set/ON condition. An event alarm that passed the threshold and changed its severity, will return automatically to event severity when meeting its Reset/OFF condition." ::= { agnListDecodingEntry 5} agnListDecodingAcmRelaySlt OBJECT-TYPE SYNTAX INTEGER { none (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the ACM slot, desired for outbound relay (report) for the selected alarm. In the ?004 Unit the entries io6(10)..io12(16) are not valid. none - when agnListDecodingType=alr AND the selected alarm should not be reported by an ACM card. notApplicable - when agnListDecodingType=sanity OR when [agnListDecodingType=alr and there is no ACM card installed in the Mux]." ::= { agnListDecodingEntry 6} agnListDecodingAcmRelayPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the ACM port within the slot, desired for outbound relay (report) for the selected alarm. notApplicable - when agnListDecodingType=sanity OR when agnListDecodingAcmRelaySlt=notApplicable." ::= { agnListDecodingEntry 7} -- Dlci Table from system point of view agnDlciTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { agnSystemDlci 1} agnDlciEntry OBJECT-TYPE SYNTAX AgnDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnDlciCnfgIdx, agnDlciLSltIdx, agnDlciLPrtIdx, agnDlciHIdx, agnDlciHSltIdx, agnDlciHPrtIdx, agnDlciLIdx } ::= { agnDlciTable 1} AgnDlciEntry ::= SEQUENCE { agnDlciCnfgIdx Integer32, agnDlciLSltIdx INTEGER, agnDlciLPrtIdx Integer32, agnDlciLIdx Integer32, agnDlciHSltIdx INTEGER, agnDlciHPrtIdx Integer32, agnDlciHIdx Integer32, agnDlciTxBc INTEGER, agnDlciTxBe INTEGER, agnDlciRxBc INTEGER, agnDlciRxBe INTEGER, agnDlciPriority Integer32, agnDlciStatus INTEGER, agnDlciSpoofing INTEGER, agnDlciFunnelEnable INTEGER, agnDlciRoutingProtocol INTEGER, agnDlciRowStatus RowStatus } agnDlciCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { agnDlciEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. agnDlciLSltIdx OBJECT-TYPE SYNTAX INTEGER { cl(3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), vs (254), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. This is the Source Slot of the DLCI. vs=Voice Switching In the ?004 Unit the entries io6(10)..io16) are not valid. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) LSlotIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx." ::= { agnDlciEntry 2} agnDlciLPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique external or internal port number, including linkSelector or encapsulator. This is the Source Port of the DLCI. 100=noConnect (for voice switching) LPrtIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx." ::= { agnDlciEntry 3} agnDlciLIdx OBJECT-TYPE SYNTAX Integer32 (0..991) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique index for each possible used DLCI(16..991). This is the Source Side of the DLCI. 0=notApplicable (for voice switching) LIdx is defined according one of the following possiblities: 1. LSlotIdx is < HSlotIdx. 2. LSlotIdx is = HSlotIdx and LPrtIdx is < HPrtIdx. 3. LSlotIdx is = HSlotIdx and LPrtIdx is = HPrtIdx but LIdx is < HIdx." ::= { agnDlciEntry 4} agnDlciHSltIdx OBJECT-TYPE SYNTAX INTEGER { cl (3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position In the Mux where the DLCI is routed to - Destination Slot. For ISDN BRI ports of MX300/30 units: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { agnDlciEntry 5} agnDlciHPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number where the DLCI is routed to - Destination Port." ::= { agnDlciEntry 6} agnDlciHIdx OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal connection DLCI number where the Source DLCI is routed to - the Destination Side of the DLCI." ::= { agnDlciEntry 7} agnDlciTxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBc5100bps (3), txBc6400bps (4), txBc8300bps (5), txBc9600bps (6), txBc14400bps (7), txBc19200bps (8), txBc28800bps (9), txBc32000bps (10), txBc38400bps (11), txBc48000bps (12), txBc56000bps (13), txBc57600bps (14), txBc64Kbps (15), txBc128Kbps (16), txBc192Kbps (17), txBc256Kbps (18), txBc320Kbps (19), txBc384Kbps (20), txBc448Kbps (21), txBc512Kbps (22), txBc768Kbps (23), txBc896Kbps (24), txBc1024Kbps (25), txBc1152Kbps (26), txBc1280Kbps (27), txBc1344Kbps (28), txBc1472Kbps (29), txBc1600Kbps (30), txBc1728Kbps (31), txBc1856Kbps (32), txBc1920Kbps (33), txBc1984Kbps (34), txBc2048Kbps (35), txBc16000bps (36), -- Added here: No room between (7) and (8). -- For Mx 30/300 txBc112Kbps (37), txBc168Kbps (38), txBc224Kbps (39), txBc336Kbps (40), txBc672Kbps (41), txBc1536Kbps (42), txBc1792Kbps (43) } MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line." DEFVAL { full } ::= { agnDlciEntry 8} agnDlciTxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBe5100bps (3), txBe6400bps (4), txBe8300bps (5), txBe9600bps (6), txBe14400bps (7), txBe19200bps (8), txBe28800bps (9), txBe32000bps (10), txBe38400bps (11), txBe48000bps (12), txBe56000bps (13), txBe57600bps (14), txBe64Kbps (15), txBe128Kbps (16), txBe192Kbps (17), txBe256Kbps (18), txBe320Kbps (19), txBe384Kbps (20), txBe448Kbps (21), txBe512Kbps (22), txBe768Kbps (23), txBe896Kbps (24), txBe1024Kbps (25), txBe1152Kbps (26), txBe1280Kbps (27), txBe1344Kbps (28), txBe1472Kbps (29), txBe1600Kbps (30), txBe1728Kbps (31), txBe1856Kbps (32), txBe1920Kbps (33), txBe1984Kbps (34), txBe2048Kbps (35), txBe16000bps (36), -- Added here: No room between (7) and (8). -- For Mx 30/300 txBe112Kbps (37), txBe168Kbps (38), txBe224Kbps (39), txBe336Kbps (40), txBe672Kbps (41), txBe1536Kbps (42), txBe1792Kbps (43) } MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line." DEFVAL { zero } ::= { agnDlciEntry 9} agnDlciRxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBc5100bps (3), rxBc6400bps (4), rxBc8300bps (5), rxBc9600bps (6), rxBc14400bps (7), rxBc19200bps (8), rxBc28800bps (9), rxBc32000bps (10), rxBc38400bps (11), rxBc48000bps (12), rxBc56000bps (13), rxBc57600bps (14), rxBc64Kbps (15), rxBc128Kbps (16), rxBc192Kbps (17), rxBc256Kbps (18), rxBc320Kbps (19), rxBc384Kbps (20), rxBc448Kbps (21), rxBc512Kbps (22), rxBc768Kbps (23), rxBc896Kbps (24), rxBc1024Kbps (25), rxBc1152Kbps (26), rxBc1280Kbps (27), rxBc1344Kbps (28), rxBc1472Kbps (29), rxBc1600Kbps (30), rxBc1728Kbps (31), rxBc1856Kbps (32), rxBc1920Kbps (33), rxBc1984Kbps (34), rxBc2048Kbps (35), rxBc16000bps (36), -- Added here: No room between (7) and (8). -- For Mx 30/300 rxBc112Kbps (37), rxBc168Kbps (38), rxBc224Kbps (39), rxBc336Kbps (40), rxBc672Kbps (41), rxBc1536Kbps (42), rxBc1792Kbps (43) } MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line." DEFVAL { full } ::= { agnDlciEntry 10} agnDlciRxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBe5100bps (3), rxBe6400bps (4), rxBe8300bps (5), rxBe9600bps (6), rxBe14400bps (7), rxBe19200bps (8), rxBe28800bps (9), rxBe32000bps (10), rxBe38400bps (11), rxBe48000bps (12), rxBe56000bps (13), rxBe57600bps (14), rxBe64Kbps (15), rxBe128Kbps (16), rxBe192Kbps (17), rxBe256Kbps (18), rxBe320Kbps (19), rxBe384Kbps (20), rxBe448Kbps (21), rxBe512Kbps (22), rxBe768Kbps (23), rxBe896Kbps (24), rxBe1024Kbps (25), rxBe1152Kbps (26), rxBe1280Kbps (27), rxBe1344Kbps (28), rxBe1472Kbps (29), rxBe1600Kbps (30), rxBe1728Kbps (31), rxBe1856Kbps (32), rxBe1920Kbps (33), rxBe1984Kbps (34), rxBe2048Kbps (35), rxBe16000bps (36), -- Added here: No room between (7) and (8). -- For Mx 30/300 rxBe112Kbps (37), rxBe168Kbps (38), rxBe224Kbps (39), rxBe336Kbps (40), rxBe672Kbps (41), rxBe1536Kbps (42), rxBe1792Kbps (43) } MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line." DEFVAL { zero } ::= { agnDlciEntry 11} agnDlciPriority OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 7 is the highest priority." ::= { agnDlciEntry 12} agnDlciStatus OBJECT-TYPE SYNTAX INTEGER { disconnected (1), connected (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected" ::= { agnDlciEntry 13} agnDlciSpoofing OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object refers to sending of RIP messages: - yes : RIP messages will be sent ONLY if there is a change in the Net. - no : RIP messages will be always sent. This object is relevant only when one side of the DLCI is a CL-NMS interface. Default=no. " ::= { agnDlciEntry 14} agnDlciFunnelEnable OBJECT-TYPE SYNTAX INTEGER { disabled (2), enabled (3), source (4), destination (5) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object selects Funnel activation: - disabled: Funnel operation will be disabled. The agnDlciTxBe and agnDlciTxBc values are not used for funneling. - enabled : Funnel operation will be enabled both for Source and Destination of the DLCI. The agnDlciTxBe and agnDlciTxBc values are used for funneling calculations. - source: Funnel operation will be enabled only for the Source of the DLCI. - destination:Funnel operation will be enabled only for the Destination of the DLCI. This object is relevant only for an encapsulating DLCI. In case of a Link Selector DLCI, the agnDlciTxBe and agnDlciTxBc values are used for bandwidth of Link Selector. Default=disabled. " ::= { agnDlciEntry 15} agnDlciRoutingProtocol OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), rip (2), rip2(3), none(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This object is relevant only when one side of the DLCI is a CL-NMS interface. It defines which Routing Protocol will be used for management via CL-NMS port. notApplicable will be used for all slots but CL. rip is a proprietary rip protocol. Default=rip. " ::= { agnDlciEntry 16} agnDlciRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute allows to create/delete a row in this table. For creating a row, the NMS should set agnRowStatus.255.id2.id3.id4.id5.id6.id7 = active(1). For destroying a row, the NMS should set: agnRowStatus.255.id2.id3.id4.id5.id6.id7 = destroy(6). Only rows with status active(1) are relevant. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { agnDlciEntry 17} -- Voice Switching Configuration Support: agnVoiceSwitching group agnVoiceSwConfTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnVoiceSwConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "MXcess Configuration for Voice Switching." ::= { agnVoiceSwitching 1 } agnVoiceSwConfEntry OBJECT-TYPE SYNTAX AgnVoiceSwConfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnVoiceSwConfIdx } ::= { agnVoiceSwConfTable 1} AgnVoiceSwConfEntry ::= SEQUENCE { agnVoiceSwConfIdx INTEGER, agnVoiceSwConfZoneId DisplayString, agnVoiceSwConfNodeId DisplayString, agnVoiceSwConfNoOfHops Integer32, agnVoiceSwConfSidt Integer32, agnVoiceSwConfLidt Integer32, agnVoiceSwConfDialPlan INTEGER } agnVoiceSwConfIdx OBJECT-TYPE SYNTAX INTEGER { active(1), temporary(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Table. Both configurations can be read but only the Temporary can be written to." ::= { agnVoiceSwConfEntry 1} agnVoiceSwConfZoneId OBJECT-TYPE SYNTAX DisplayString(SIZE(1..2)) MAX-ACCESS read-write STATUS current DESCRIPTION "1 or 2 digits, (0-9)(1-9)." ::= { agnVoiceSwConfEntry 2} agnVoiceSwConfNodeId OBJECT-TYPE SYNTAX DisplayString(SIZE(1..3)) MAX-ACCESS read-write STATUS current DESCRIPTION "1, 2 or 3 digits, (1-9),(0-9),(0-9)." ::= { agnVoiceSwConfEntry 3} agnVoiceSwConfNoOfHops OBJECT-TYPE SYNTAX Integer32 (0..20) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of hops the frame will go through the net before deciding to discard the frame (like time-to-live in IP). 0 = notApplicable Default=20 ." ::= { agnVoiceSwConfEntry 4} agnVoiceSwConfSidt OBJECT-TYPE SYNTAX Integer32 (0..30) MAX-ACCESS read-write STATUS current DESCRIPTION "SIDT: Short Inter Digit Timeout used as timer (in sec.) between digits after routing is completed. The timeout indicates end of dialing and the call can then be setup. 0 = notApplicable Default=2 sec." ::= { agnVoiceSwConfEntry 5} agnVoiceSwConfLidt OBJECT-TYPE SYNTAX Integer32 (0..30) MAX-ACCESS read-write STATUS current DESCRIPTION "LIDT: Long Inter Digit Timeout used as timer between digits before routing is completed. If no digits were dialed and LIDT expired then the user will get an error tone and the call will be disconnected. 0 = notApplicable Default=15 sec." ::= { agnVoiceSwConfEntry 6} agnVoiceSwConfDialPlan OBJECT-TYPE SYNTAX INTEGER { staticDialPlan(2), staticDialPlanPlus(3), flexDialPlan(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Dialing Plan method that will be used in the Voice Switching. Static Dialing Plan - Routing is defined by the current device Zone and Node ID in the Network. Static Dialing Plan Plus - Includes the Static Dialing Plan but contains an addition of defining the number of dialed digits. Flexible Dialing Plan - Routing is defined in a flexible form. In this plan the user can configure the extension number of a local voice channel, Route a call to a remote destination and enter the Number of Digits for a specific dial prefix." ::= { agnVoiceSwConfEntry 7} agnVoiceSwConfRtTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnVoiceSwConfRtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Routing Table for Voice Switching." ::= { agnVoiceSwitching 2 } agnVoiceSwConfRtEntry OBJECT-TYPE SYNTAX AgnVoiceSwConfRtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnVoiceSwConfRtDbId, agnVoiceSwConfRtIdx } ::= { agnVoiceSwConfRtTable 1} AgnVoiceSwConfRtEntry ::= SEQUENCE { agnVoiceSwConfRtDbId INTEGER, agnVoiceSwConfRtIdx Integer32, agnVoiceSwConfRtDigits DisplayString, agnVoiceSwConfRtAction INTEGER, agnVoiceSwConfRtData DisplayString, agnVoiceSwConfRtSlot INTEGER, agnVoiceSwConfRtPort Integer32, agnVoiceSwConfRtDlci Integer32, agnVoiceSwConfRtRowStatus RowStatus, agnVoiceSwConfRtMaxCalls Integer32, agnVoiceSwConfRtPriority Integer32 } agnVoiceSwConfRtDbId OBJECT-TYPE SYNTAX INTEGER { active(1), temporary(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Table. Both configurations can be read but only the Temporary can be written to." ::= { agnVoiceSwConfRtEntry 1 } agnVoiceSwConfRtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION " The Index of the row." ::= { agnVoiceSwConfRtEntry 2 } agnVoiceSwConfRtDigits OBJECT-TYPE SYNTAX DisplayString ( SIZE(1..7) ) MAX-ACCESS read-create STATUS current DESCRIPTION " Dialed digits: Series of digits 0...9, '*', '#' or '%'. The '*' and '#' can have many uses according to the user's decision. For example, they can be used as part of the Dialed Number, they exist on the phone number panel. '*' can also be used instead of a series of numbers. The '%' means any digits (wildcard) and is used without a series of digits. When the agnVoiceSwConfRtAction is del (7), the series of digits that are configured via this MIB object will be deleted from the prefix of the dialed number." ::= { agnVoiceSwConfRtEntry 3 } agnVoiceSwConfRtAction OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), zone(2), node(3), shortDialing(4), in(5), -- Internal switching hgr(6), -- Hunt Group del(7), -- Delete a prefix from the Dialed Number rep(8), -- Replace a prefix with a given string of digits pri(9), -- for ISDN bri(10),-- for ISDN numDigDP(11), -- Number of Digits user will dial according to Dialing Plan. route(12), -- Route to a Remote Destination ext(13) -- Extension to a local voice channel } MAX-ACCESS read-create STATUS current DESCRIPTION " Action that the system should perform for the digits: agnVoiceSwConfRtDigits. The action that is allowed depends on the Dialing Plan. Here is the list of the allowed actions: For Static Dialing Plan - zone, node, in, shortDialing, hgr, del, rep For Static Dialing Plan Plus - zone, node, in, shortDialing, hgr, del, rep, numDigDP For Flexible Dialing Plan - hgr, del, rep, numDigDP, route, ext" DEFVAL { notApplicable } ::= { agnVoiceSwConfRtEntry 4 } agnVoiceSwConfRtData OBJECT-TYPE SYNTAX DisplayString(SIZE(1..7)) MAX-ACCESS read-create STATUS current DESCRIPTION " This field is relevant for actions hgr(6), and rep(8), numDigDP(11) and contains the following information: For hgr - the number of the Hunt Group. For rep - the number of digits to be replaced with. For numDigDP - the number of digits collected before establishing the call. 0 indicates no defined length. In this case SIDT will be used." -- DEFVAL {"0" } ::= { agnVoiceSwConfRtEntry 5 } agnVoiceSwConfRtSlot OBJECT-TYPE SYNTAX INTEGER{ noConnect(2), cl (3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-create STATUS current DESCRIPTION " Routing Slot- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13)." DEFVAL { noConnect } ::= { agnVoiceSwConfRtEntry 6 } agnVoiceSwConfRtPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION " Routing Port- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13). 100=noConnect (for non-routing case)." DEFVAL { 0 } ::= { agnVoiceSwConfRtEntry 7 } agnVoiceSwConfRtDlci OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION " Routing DLCI- Relevant for actions zone(2), node(3), shortDialing(4), route(12), ext(13). Valid values: 0=notApplicable (for non-routing case). 1, 16..991 " DEFVAL { 15 } ::= { agnVoiceSwConfRtEntry 8 } agnVoiceSwConfRtRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION " Status of the row for creating/deleting entries in the table. The only possible supported RowStatus vaules are active (1), notInService (2), notReady(3), createAndGo(4), createAndWait(5) and destroy(6)." ::= { agnVoiceSwConfRtEntry 9 } agnVoiceSwConfRtMaxCalls OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Maximum no. of simultaneous voice calls that are allowed in the direction defined by the current entry. Default=0 (No Limit)." ::= { agnVoiceSwConfRtEntry 10} agnVoiceSwConfRtPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates a unique priority of the Voice Switching Route. 1 is the lowest priority and 7 is the highest priority. 0 means N/A " ::= { agnVoiceSwConfRtEntry 11} agnVoiceSwConfHGTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnVoiceSwConfHGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Hunt Groups." ::= { agnVoiceSwitching 5 } agnVoiceSwConfHGEntry OBJECT-TYPE SYNTAX AgnVoiceSwConfHGEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { agnVoiceSwConfHGdbIdx, agnVoiceSwConfHGIdx } ::= { agnVoiceSwConfHGTable 1} AgnVoiceSwConfHGEntry ::= SEQUENCE { agnVoiceSwConfHGdbIdx INTEGER, agnVoiceSwConfHGIdx Integer32, agnVoiceSwConfHGConnect INTEGER, agnVoiceSwConfHGExt Integer32, agnVoiceSwConfHGExtString SnmpAdminString, agnVoiceSwConfHGUserParams SnmpAdminString, agnVoiceSwConfHGStatus INTEGER } agnVoiceSwConfHGdbIdx OBJECT-TYPE SYNTAX INTEGER { active(1), temporary(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Active or Temporary Table. Both configurations can be read but only the Temporary can be written to." ::= { agnVoiceSwConfHGEntry 1} agnVoiceSwConfHGIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "For Vmux-300 devices - This object represents a combination of - Hunt Group number and Extension number OR - Port number and Extension number. For other devices (e.g. MXcess, MP-2100H) - There may be up to 10 Hunt Groups per MXcess. That's the index of the hunt group relevant to this row." ::= { agnVoiceSwConfHGEntry 2} agnVoiceSwConfHGConnect OBJECT-TYPE SYNTAX INTEGER { no(2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the hunt group should be considered in any of the mux algorithms." ::= { agnVoiceSwConfHGEntry 3} agnVoiceSwConfHGExt OBJECT-TYPE SYNTAX Integer32(0..99) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the extension number of the hunt group. 0 is for not valid. The allowed range is 10 - 99." DEFVAL { 0 } ::= { agnVoiceSwConfHGEntry 4} agnVoiceSwConfHGExtString OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-write STATUS current DESCRIPTION "This is the extension string of the hunt group. This string is a combination of digits, * and #." ::= { agnVoiceSwConfHGEntry 5} agnVoiceSwConfHGUserParams OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the User's parameters." ::= { agnVoiceSwConfHGEntry 6} agnVoiceSwConfHGStatus OBJECT-TYPE SYNTAX INTEGER { active (1), notInService (2), notReady (3), createAndGo (4), createAndWait (5), destroy (6), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables the user to create/delete entries in this table. Its usage for values (1)..(6) should be identical to RowStatus SYNTAX. notApplicable(255) - should be used when the table is static (i.e. whenever create/delete entries is not allowed)." ::= { agnVoiceSwConfHGEntry 7} -- -- Signaling Profiles for MP-2200 and MP-2100 -- -- Legacy Profile Table agnSigProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSigProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "- For products supporting more than one configuration, the write operation into the Table is valid only to the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table will be to agnSigProfileCnfgIdx=1. The table includes signaling profile parameters for Legacy Profiles." ::= { agnSigProfile 1} agnSigProfileEntry OBJECT-TYPE SYNTAX AgnSigProfileEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnSigProfileCnfgIdx, agnSigProfileIdx, agnSigProfileRxTx} ::= { agnSigProfileTable 1} AgnSigProfileEntry ::= SEQUENCE { agnSigProfileCnfgIdx Integer32, agnSigProfileIdx Integer32, agnSigProfileRxTx INTEGER, agnSigProfileABCD OCTET STRING, agnSigProfileEcanActSignal INTEGER, agnSigProfileEcanRespDelay Unsigned32 } agnSigProfileCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. For products supporting more than one configuration,the write operation is valid only to the TmpCnfg. For Gmux2000 the range limitation (1..255) was discarded since the Idx is computed as: x 1000 + 255." ::= { agnSigProfileEntry 1} agnSigProfileIdx OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Signaling Profile (1..5). For MP-104/204, only Profile=1 will exist." ::= { agnSigProfileEntry 2} agnSigProfileRxTx OBJECT-TYPE SYNTAX INTEGER { rx (1), tx (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates if the following objects refer to: Rx or Tx translation. Rx : ML->IO Tx : IO->ML . For MP-104/204, that means: Rx : Signaling to FXS CH Tx : Signaling to E1 Link. " ::= { agnSigProfileEntry 3} agnSigProfileABCD OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "For MP-2100/MP-2200 and for MP-104/204 from R2: This object represents 6 parameters, by 3 Octets : Busy Code-MSB nibble, - applicable only for Rx translation Idle Code- nibble, - applicable only for Rx translation D Bit Code- nibble, C Bit Code- nibble, B Bit Code- nibble, A Bit Code-LSB nibble. Each of Busy and Idle Code nibble will have the valid values: 0000 .. FFFF. Each of A,B,C,D Bit Code nibble represents: 0 hex = 0000 = 0 1 hex = 0001 = 1 2 hex = 0010 = A bit 3 hex = 0011 = B bit 4 hex = 0100 = C bit 5 hex = 0101 = D bit 6 hex = 0110 = A bit inverse 7 hex = 0111 = B bit inverse 8 hex = 1000 = C bit inverse 9 hex = 1001 = D bit inverse A-F hex - not used (invalid values) For MP-104/204 R1: This object represents 3 parameters, by 2 Octets : Bit 1 = Bit A - OFF Hook for Tx ; Ring for Rx (LSB) Bit 2 = Bit B - OFF Hook for Tx ; Ring for Rx Bit 3 = Bit C - OFF Hook for Tx ; Ring for Rx Bit 4 = Bit D - OFF Hook for Tx ; Ring for Rx Bit 5 = Bit A - ON Hook for Tx ; Idle for Rx Bit 6 = Bit B - ON Hook for Tx ; Idle for Rx Bit 7 = Bit C - ON Hook for Tx ; Idle for Rx Bit 8 = Bit D - ON Hook for Tx ; Idle for Rx Bit 9 = Bit A - OOS State for both Tx and Rx Bit 10 = Bit B - OOS State for both Tx and Rx Bit 11 = Bit C - OOS State for both Tx and Rx Bit 12 = Bit D - OOS State for both Tx and Rx Bit 13 = Spare (always 0) Bit 14 = Spare (always 0) Bit 15 = Spare (always 0) Bit 16 = Spare (always 0) (MSB) When the object is not applicable, the Octet String will have 0 bytes." ::= { agnSigProfileEntry 4} agnSigProfileEcanActSignal OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), aBit1 (2), aBit0 (3), bBit1 (4), bBit0 (5), cBit1 (6), cBit0 (7), dBit1 (8), dBit0 (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo Canceller Activation Signal. This object specifies which BIT (A, B, C, or D) and which value (0 or 1) will be used for the echo canceller activation. The inverse value will cause the deactivation of the echo canceller." ::= { agnSigProfileEntry 5} agnSigProfileEcanRespDelay OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Echo Canceller Response Delay. This object specifies the response delay in msec for the activation/deactivation of the echo canceller. The value should be in multiples of 100 msec: 100, 200, 300, ...2000." ::= { agnSigProfileEntry 6} -- General Profile Table agnSigProfTable OBJECT-TYPE SYNTAX SEQUENCE OF AgnSigProfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry. This is the general table of signaling profiles." ::= { agnSigProfile 2} agnSigProfEntry OBJECT-TYPE SYNTAX AgnSigProfEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {agnSigProfCnfgIdx, agnSigProfIdx} ::= { agnSigProfTable 1} AgnSigProfEntry ::= SEQUENCE { agnSigProfCnfgIdx Integer32, agnSigProfIdx Integer32, agnSigProfName DisplayString, agnSigProfType INTEGER } agnSigProfCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= { agnSigProfEntry 1} agnSigProfIdx OBJECT-TYPE SYNTAX Integer32 (1..5) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Signaling Profile (1..5)." ::= { agnSigProfEntry 2} agnSigProfName OBJECT-TYPE SYNTAX DisplayString(SIZE(0..12)) MAX-ACCESS read-write STATUS current DESCRIPTION "Profile Name given by user." ::= { agnSigProfEntry 3 } agnSigProfType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), legacy (2), r2Cas (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Profile Type. legacy - usual signaling. The parameters for the Legacy Profiles are detailed in the agnSigProfileTable, above. r2Cas - R2 signaling. The parameters for the R2 Profiles are detailed in the r2 ProfileCnfg tables (belong to r2If). " ::= { agnSigProfEntry 4 } -- -- TS Assignment Table from system point of view -- -- agnTsTable OBJECT-TYPE ::= { agnSystemTs 1} -- -- For this table see tsa.txt file. -- General System Voice parameters -- systemVoiceTable OBJECT-TYPE SYNTAX SEQUENCE OF SystemVoiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "General Parameters for voice - system level." ::= { systemVoice 1 } systemVoiceEntry OBJECT-TYPE SYNTAX SystemVoiceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { systemVoiceConfIdx } ::= { systemVoiceTable 1} SystemVoiceEntry ::= SEQUENCE { systemVoiceConfIdx Integer32, systemVoiceNationalTone INTEGER, systemVoicePacketRate Unsigned32, systemVoiceFaxSupport INTEGER, systemVoiceFaxRate INTEGER, systemVoiceModemSupport INTEGER, systemVoiceCoderAndRate INTEGER, systemVoiceEchoCanceler INTEGER, systemVoiceTxGain Integer32, systemVoiceDtmfRelayMethod INTEGER, systemVoiceDtmfRelayRxPayloadType Unsigned32, systemVoiceDtmfRelayPayloadTypeNeg INTEGER, systemVoiceDtmfRelayTxPayloadType Unsigned32 } systemVoiceConfIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed - Active or Temporary Configurations. Idx 255 relates to the temporary TmpCnfg. All configurations can be read but only the Temporary can be written to." ::= { systemVoiceEntry 1} systemVoiceNationalTone OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), usa (2), australia (3), brazil (4), canada (5), france (6), germany (7), israel (8), mexico (9), portugal (10), russia (11), spain (12), unitedKingdom (13), czech (14), china (15) } MAX-ACCESS read-write STATUS current DESCRIPTION "Tone Characteristics (Amplitude, Frequency, delays etc.). These characteristics are defined according to the country." ::= { systemVoiceEntry 2} systemVoicePacketRate OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the G.729 and G.711 Coders transmitted Packet Rate in milliseconds." ::= { systemVoiceEntry 3} systemVoiceFaxSupport OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), faxRelayT38 (3), vbdPassThrou (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows the user to Disable/Enable Fax support." ::= { systemVoiceEntry 4} systemVoiceFaxRate OBJECT-TYPE SYNTAX INTEGER { notConnected (1), r4800bps (2), -- reserved for r7200bps (3) r9600bps (4), -- reserved for r12000bps (5) r14400bps (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Fax Rate limit. It is irrelevant when Fax support is NA or disabled." ::= { systemVoiceEntry 5} systemVoiceModemSupport OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), vbdV152 (3), vbdPassThrou (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object allows the user to Disable/Enable Modem support." ::= { systemVoiceEntry 6} systemVoiceCoderAndRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), -- reserved for g7231r6300BPS (2) -- reserved for g7231r5300BPS (3) -- reserved for g729A8KBPS (4) g711aLAW (5), g711uLAW (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Coder and Rate for the Voice Compression." ::= { systemVoiceEntry 7} systemVoiceEchoCanceler OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Echo Canceler activation." ::= { systemVoiceEntry 8} systemVoiceTxGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Transmit Gain (volume) in dB." ::= { systemVoiceEntry 9} systemVoiceDtmfRelayMethod OBJECT-TYPE SYNTAX INTEGER { rfc2833 (1), sipInfo (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the DTMF Relay Method that is used to transmit DTMF tones. rfc2833(1) - inband DTMF relay according to RFC-2833. sipInfo(2) - out of band DTMF relay using SIP INFO method." ::= { systemVoiceEntry 10} systemVoiceDtmfRelayRxPayloadType OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Rx Payload Type for DTMF relay RTP packets. It is relevant only when DTMF Relay Method is RFC-2833." ::= { systemVoiceEntry 11} systemVoiceDtmfRelayPayloadTypeNeg OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether Payload Type Negotiation is used (according to RFC-2833) or not. It is relevant only when DTMF Relay Method is RFC-2833." ::= { systemVoiceEntry 12} systemVoiceDtmfRelayTxPayloadType OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Tx Payload Type for DTMF relay RTP packets. It is relevant only when the Payload Type Negotiation is disabled." ::= { systemVoiceEntry 13} systemVoiceCoderTable OBJECT-TYPE SYNTAX SEQUENCE OF SystemVoiceCoderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Voice Coders table." ::= { systemVoice 2 } systemVoiceCoderEntry OBJECT-TYPE SYNTAX SystemVoiceCoderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in Voice Coders table." INDEX { systemVoiceCoderConfIdx, systemVoiceCoderPriority } ::= { systemVoiceCoderTable 1} SystemVoiceCoderEntry ::= SEQUENCE { systemVoiceCoderConfIdx Unsigned32, systemVoiceCoderPriority Unsigned32, systemVoiceCoderCoderAndRate INTEGER } systemVoiceCoderConfIdx OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The first index of the table. This object might represent the Configuration Index (1..100) being accessed; Index=255 relates to the TmpCnfg. For devices with multiple configurations, Set is permitted to TmpCnfg(255) only. Not-Applicable = 1." ::= { systemVoiceCoderEntry 1} systemVoiceCoderPriority OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the Coder's Priority." ::= { systemVoiceCoderEntry 2} systemVoiceCoderCoderAndRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), g7231r6300BPS (2), g7231r5300BPS (3), g729A8KBPS (4), g711aLAW (5), g711uLAW (6), none (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Coder and Rate for the Voice Compression." ::= { systemVoiceCoderEntry 3} -- -- Wan installed module status general information -- mdlSInstTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlSInstEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { statMdlGen 1 } mdlSInstEntry OBJECT-TYPE SYNTAX MdlSInstEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlSInstSltIdx } ::= { mdlSInstTable 1} MdlSInstEntry ::= SEQUENCE { mdlSInstSltIdx INTEGER, mdlSInstCardType INTEGER, mdlSHwVersion DisplayString, mdlSSwVersion DisplayString, mdlSAlrStatus INTEGER, mdlSAlrStatusAll INTEGER, mdlSMaskedAlrStat INTEGER, mdlSMaskedAlrStatAll INTEGER, mdlSTstStatusAll INTEGER, mdlSClearAlrCmd INTEGER, mdlSClearAllAlrCmd INTEGER, mdlSTemperature Integer32 } mdlSInstSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify a slot position in the mux. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid. For the Vmux2100 Main Board clA (3) is used." ::= { mdlSInstEntry 1} mdlSInstCardType OBJECT-TYPE SYNTAX INTEGER { -- -- General types -- unknown (1), empty (2), -- (3)..(7) are reserved ; they appear in the compress structure acm (9), --alarm module -- -- Power Supply Modules -- ps60W (10), ps100W (11), -- (12)..(16) are reserved for the Programmed PS cards ps (17), -- -- Cl Modules -- cl1 (20), clEth (21), cl2 (22), cl2Eth (23), cl3 (24), cl3Eth (25), cl1Clk (26), --CL1 with Station Clock (for LRS102) -- -- Packet Cards of Megaplex -- mPh1 (31), mPh3 (32), mPh1T1DSU (33), mPh1T1CSU (34), mPh1E1DSU (35), mPh1E1LTU (36), -- TDM Cards mtmlFT1 (37), mtmlFE1 (38), mtmlH4E1 (39), mtmlH4E12W (40), mtmlH4T1 (41), mtmlH4T12W (42), mtHsh4E1 (43), mtHsh4E12W (44), mtHsh4T1 (45), mtHsh4T12W (46), mtmlH2E1 (47), mtmlH2E12W (48), mtmlH2T1 (49), mtmlH2T12W (50), hsh2E1 (51), hsh2E12W (52), hsh2T1 (53), hsh2T12W (54), mlIp (55), mtml4Ip (56), ml20N1 (57), ml20N2 (58), -- Packet Cards of Megaplex mPl6 (60), mPl3 (61), -- VF cards of Megaplex vf24T1 (62), vf30E1 (63), vf48T1 (64), vf60E1 (65), -- Vmux-2100 Main Link cards ml2E1 (68), ml4E1 (69), ml2T1 (70), ml4T1 (71), mPv4 (72), -- -- TDM Cards -- vc16A (73), vc8EandM (74), vc8Fxo (75), vc8Fxs (76), vc16EandM (77), vc16Fxo (78), vc16Fxs (79), vf3EandM (80), vf3Fxs (81), vf3Fxo (82), vfPbx (83), vfPbxT1 (84), vfPbxE1 (85), mtMlE2S (86), --Single Link mtMlE2D (87), --Dual Link mtMlF2T1 (88), mtMlF2E1 (89), mtMlT1Fiber (90), mtMlE1Fiber (91), mtMlT1FiberFb (92), mtMlE1FiberFb (93), mtmlHE1 (94), mtmlH1E1 (95), mtmlHSE1 (96), ml20 (97), mtMl4T1 (98), mtMl4E1 (99), mtMl1T1DSU (100), mtMl1T1CSU (101), mtMl1E1DSU (102), mtMl1E1LTU (103), mtMl1T1DSUfb (104), mtMl1T1CSUfb (105), mtMl1E1DSUfb (106), mtMl1E1LTUfb (107), mtMl2T1 (108), mtMl2E1 (109), ls2CcittX50 (110), ls2CcittX58 (111), ls2ATandTSdm (112), ls2ACcittX50 (113), ls2ACcittX58 (114), ls2AATandTSdm (115), ls2A2Ts (116), ls2M (117), mtMlT1 (118), mtMlE1 (119), hs2 (120), hs3 (121), hsq (122), hs703 (123), hsQM (124), hsqN (125), hs6 (126), hs12 (127), hsDp (128), hsp (129), hs4T1 (130), hs4E1 (131), hs4 (132), hsEth (133), ml8T1 (134), ml8E1 (135), -- Vmux-2100 Voice cards vc2E1 (136), vc4E1 (137), vc2T1 (138), vc4T1 (139), vc2EandM (140), vc2Fxs1Plar (141), vc2Fxo1 (142), vc2Fxs2 (143), vc2Fxo2 (144), vc2Fxs3 (145), vc2Fxo3 (146), vc26EandM (147), mtvc2 (148), vc2R2Fxs (149), hsu (150), mbeA (151), mbeB (152), mbeU (153), tre (154), hsuI (155), hsr (156), hss (157), hsu1 (158), ls12 (159), ls6 (160), ls6V1EandM (161), ls6V1Fxo (162), ls6V1Fxs (163), ls6V2EandM (164), ls6V2Fxo (165), ls6V2Fxs (166), ls6VfEandM (167), ls6VfFxo (168), ls6VfFxs (169), vc3EandM (170), vc3Fxo (171), vc3Fxs (172), vcPbx (173), vcPbxT1 (174), vcPbxE1 (175), vc6EandM (176), vc6Fxo (177), vc6Fxs (178), vcq (179), ls6n (180), -- -- Packet Cards of MAXcess and Hybrid -- -- High speed cards mhs1V36 (181), mhs1V35 (182), mhs1G703 (183), mhs1DDS (184), mhs3 (185), mhs1X21 (186), mhs1V24 (187), mhs4 (188), mhsE1Hs (189), mhsT1Hs (190), mhsHyE1Hs (191), -- 2 HS ports + 1 Hybrid E1 port mhsHyT1Hs (192), -- 2 HS ports + 1 Hybrid T1 port mlfHybE1Hs (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port mlfHybT1Hs (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port -- T1/E1 cards mhs2e1 (195), mhs2t1 (196), mhsHy2e1 (197), -- 2 Hybrid E1 ports mhsHy2t1 (198), -- 2 Hybrid T1 ports mlfHybE12 (199), -- Fiber Optic Hybrid: 2 E1 ports -- Low speed cards mls6 (200), mls3 (201), -- More T1/E1 cards mlHybAtmE1 (202), -- Hybrid ATM E1 mlHybAtmT1 (203), -- Hybrid ATM T1 mlfHybT12 (204), -- Fiber Optic Hybrid: 2 T1 ports -- Voice cards mvc8 (205), -- MVC-8 name in marketing: MVC-4N mvc8PbxE1 (206), mvc8PbxT1Dsu (207), mvc8PbxT1Csu (208), mvc8PbxE1Slave (209), mvc4 (210), mvc4PbxE1 (211), mvc4PbxT1Dsu (212), mvc4PbxT1Csu (213), mvc4PbxE1Slave (214), mvc4PbxT1Slave (215), mvc8PbxT1Slave (216), -- MVC-8 T1 Slave is here mvc8ExtAnalog (217), -- MVC-8 with 8 External ports mvcE1 (218), -- 8 External ports & 30 Internals mvcT1 (219), -- 8 External ports & 24 Internals -- ISDN for Maxcess mhsS (220), mhsU (221), mhsPriE1 (222), mhsPriT1 (223), --Card of MP-2100/4 hsEthSwitch (224), -- CCS for Maxcess & MPH mPriE1FramerCcs (225), mPriT1FramerCcs (226), mPriE1SlaveCcs (227), mPriT1SlaveCcs (228), mDualBri (229), --Voice cards for MP vc12EandM (230), vc12Fxo (231), vc12Fxs (232), vc6aEandM (233), vc6aFxo (234), vc6aFxs (235), vc6AgFxo (236), vc6AgFxs (237), vc6a4LB (238), --Video card for MP vid (239), --ISDN cards for MP hsu12 (240), hsu6 (241), hss12 (242), hss6 (243), -- MPH and MP-2100/4 cards hsDp3 (244), hsDp6 (245), -- MP-2100/4 card hsf1 (246), -- More Hybrid cards + IP cards for MPH mhsHyE1 (247), -- 1 Hybrid E1 port mhsHyT1 (248), -- 1 Hybrid T1 port mhsIp (249), -- 1 Eth port + 1 HS port mlIpHs (250), -- 1 Eth port + 3 HS ports mlHybIpE1 (251), -- 1 Eth port + 1 HS port + 1 E1 mlHybIpT1 (252), -- 1 Eth port + 1 HS port + 1 T1 -- VOIP cards for MPH & MX mvg1Lan (253), mvg2Lan (254), -- MP-2100/4 card vc4Fxs (255), vc4EandM (256), vc4Fxo (257), hsf2 (258), -- More VOIP cards for MPH mvgSwitch4Lan (260), --SHDSL cards of Megaplex msl4E1W2 (261), msl4E1W4 (262), msl8E1W2 (263), msl4E1W2Eth (264), msl8E1W2Eth (265), asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH) asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH) asmi54c (268), -- & LRS-102 (ETH only) --HS cards of Megaplex hs6N (271), hs12N (272), hsNRZ (273), -- Vmux 2100 Enhanced Voice Cards evc2E1 (281), evc4E1 (282), evc2T1 (283), evc4T1 (284), -- Vmux-2200 Voice cards vc2E1Pri (285), vc4E1Pri (286), -- MP Voice cards vc4OmniEandM (291), vc4OmniWestern (292), -- MP-4100 and/or LRS-102 cards clx1 (301), clx1GbE (302), clx1S155 (303), clx1S155GbE (304), ml8T1Eth (305), ml8E1Eth (306), op106cEth (307), --no external T1 op108cEth (308), --no external E1 op106cEthT1 (309), --with external T1 (used also by LRS-102) op108cEthE1 (310), --with external E1 (used also by LRS-102) op108cEthE1Unbal (311), --used only by LRS-102 mpw1 (312), -- VFS cards of Megaplex vfs24T1 (321), vfs30E1 (322), vfs48T1 (323), --2T1 vfs60E1 (324), --2E1 -- MiniCVS cards mm4E1 (325), mm4T1 (326), mm8E1 (327), mm8T1 (328), mm12E1 (329), mm12T1 (330), mm16E1 (331), mm16T1 (332) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the type of card installed in the specific slot position. Only PS cards are possible in the PS slots. Only CL cards are possible in the CL slots. Only IO cards are possible in the IO slots." ::= { mdlSInstEntry 2} mdlSHwVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Hardware version of the installed card in the specific slot position." ::= { mdlSInstEntry 3 } mdlSSwVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Software version of the installed card in the specific slot position." ::= {mdlSInstEntry 4} mdlSAlrStatus OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state at module level, i.e. lower level (port alarms) status is not included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { mdlSInstEntry 5 } mdlSAlrStatusAll OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the module-all level, i.e. lower level (port alarms) included. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { mdlSInstEntry 6 } mdlSMaskedAlrStat OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state at module level, [i.e. lower level (port alarms) status is not included],including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { mdlSInstEntry 7 } mdlSMaskedAlrStatAll OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the module-all level, i.e. lower level (port alarms) included, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { mdlSInstEntry 8 } mdlSTstStatusAll OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute will be set to on(3) when there is at least one test in progress on a channel of the card, otherwise the value will be off(2)." ::= { mdlSInstEntry 9 } mdlSClearAlrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this command to ON, enforces a clear of all the alarms in the given slot, excluding alarms of port level. The clear operation will not be applied for masked/inverted alarms." ::= { mdlSInstEntry 10 } mdlSClearAllAlrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this command to ON, enforces a clear of all the alarms in the given slot, including all its ports alarms. The clear operation will not be applied for masked/inverted alarms." ::= { mdlSInstEntry 11 } mdlSTemperature OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature of the card, in Celsius degrees." ::= { mdlSInstEntry 12 } mdlSAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of card agent alarms ; includes also an alarm indicating existence of alarms on its ports if there are any." ::= { statMdlGen 2 } mdlSAlrEntry OBJECT-TYPE SYNTAX MdlSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {mdlSAlrSltIdx , mdlSAlrIdx} ::= { mdlSAlrTable 1} MdlSAlrEntry ::= SEQUENCE { mdlSAlrSltIdx INTEGER, mdlSAlrIdx Integer32, mdlSAlrCodeDescription DisplayString, mdlSAlrCode Integer32, mdlSAlrSeverity INTEGER, mdlSAlrState INTEGER, mdlSAlrCounter Integer32, mdlSAlrMask INTEGER, mdlSAlrInvert INTEGER } mdlSAlrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive." ::= { mdlSAlrEntry 1} mdlSAlrSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid. For the Vmux2100 Main Board clA (3) is used." ::= { mdlSAlrEntry 2} mdlSAlrCodeDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a full text description of the alarm . The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter." ::= { mdlSAlrEntry 3} mdlSAlrCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A code identifying the alarm of an entry in the alarm status table at card level." ::= { mdlSAlrEntry 4 } mdlSAlrSeverity OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the alarm." ::= { mdlSAlrEntry 5 } mdlSAlrState OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the alarm." ::= { mdlSAlrEntry 6 } mdlSAlrCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately." ::= { mdlSAlrEntry 7 } mdlSAlrMask OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm mask : on/off." ::= { mdlSAlrEntry 8 } mdlSAlrInvert OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm invert : on/off." ::= { mdlSAlrEntry 9 } -- -- Wan module configuration information -- mdlCPrgTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlCPrgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cnfgMdlGen 1 } mdlCPrgEntry OBJECT-TYPE SYNTAX MdlCPrgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlCCnfgIdx, mdlCSltIdx } ::= { mdlCPrgTable 1} MdlCPrgEntry ::= SEQUENCE { mdlCCnfgIdx Integer32, mdlCSltIdx INTEGER, mdlCPrgCardType INTEGER, mdlCNoOfExternPrt Integer32, -- RO mdlCNoOfInternPrt Integer32, -- RO mdlCWorkMode INTEGER, mdlCDhcpClientEnable INTEGER, mdlCRdnExists INTEGER, -- RO mdlCInterfaces OCTET STRING } mdlCCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg(1..100) being referred. Value 255 specifies the TmpCnfg " ::= { mdlCPrgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. mdlCSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid." ::= { mdlCPrgEntry 2} mdlCPrgCardType OBJECT-TYPE SYNTAX INTEGER { -- -- General types -- unknown (1), empty (2), -- (3)..(7) are reserved ; they appear in the compress structure acm (9), --alarm module -- -- Power Supply Modules -- ps48x60W (10), ps48x100W (11), ps110x60W (12), ps110x100W (13), ps220x60W (14), ps220x100W (15), ps180W (16), ps (17), -- -- Cl Modules -- cl1 (20), clEth (21), cl2 (22), cl2Eth (23), cl3 (24), cl3Eth (25), cl1Clk (26), --CL1 with Station Clock (for LRS102) -- -- Packet Cards of Megaplex -- mPh1 (31), mPh3 (32), mPh1T1DSU (33), mPh1T1CSU (34), mPh1E1DSU (35), mPh1E1LTU (36), -- TDM Cards mtmlFT1 (37), mtmlFE1 (38), mtmlH4E1 (39), mtmlH4E12W (40), mtmlH4T1 (41), mtmlH4T12W (42), mtHsh4E1 (43), mtHsh4E12W (44), mtHsh4T1 (45), mtHsh4T12W (46), mtmlH2E1 (47), mtmlH2E12W (48), mtmlH2T1 (49), mtmlH2T12W (50), hsh2E1 (51), hsh2E12W (52), hsh2T1 (53), hsh2T12W (54), mlIp (55), mtml4Ip (56), ml20N1 (57), ml20N2 (58), -- Packet Cards of Megaplex mPl6 (60), -- mPl3 (61), -- VF cards of Megaplex vf24T1 (62), vf30E1 (63), vf48T1 (64), vf60E1 (65), -- Vmux-2100 Main Link cards ml2E1 (68), ml4E1 (69), ml2T1 (70), ml4T1 (71), -- mPv4 (72), -- -- TDM Cards -- vc16A (73), vc8EandM (74), vc8Fxo (75), vc8Fxs (76), vc16EandM (77), vc16Fxo (78), vc16Fxs (79), vf3EandM (80), vf3Fxs (81), vf3Fxo (82), vfPbx (83), vfPbxT1 (84), vfPbxE1 (85), mtMlE2S (86), --Single Link mtMlE2D (87), --Dual Link mtMlF2T1 (88), mtMlF2E1 (89), mtMlT1Fiber (90), mtMlE1Fiber (91), mtMlT1FiberFb (92), mtMlE1FiberFb (93), mtmlHE1 (94), mtmlH1E1 (95), mtmlHSE1 (96), ml20 (97), mtMl4T1 (98), mtMl4E1 (99), mtMl1T1DSU (100), mtMl1T1CSU (101), mtMl1E1DSU (102), mtMl1E1LTU (103), mtMl1T1DSUfb (104), mtMl1T1CSUfb (105), mtMl1E1DSUfb (106), mtMl1E1LTUfb (107), mtMl2T1 (108), mtMl2E1 (109), ls2CcittX50 (110), ls2CcittX58 (111), ls2ATandTSdm (112), ls2ACcittX50 (113), ls2ACcittX58 (114), ls2AATandTSdm (115), ls2A2Ts (116), ls2M (117), mtMlT1 (118), mtMlE1 (119), hs2 (120), hs3 (121), hsq (122), hs703 (123), hsQM (124), hsqN (125), hs6 (126), hs12 (127), hsDp (128), hsp (129), hs4T1 (130), hs4E1 (131), -- hs4 (132), hsEth (133), ml8T1 (134), ml8E1 (135), -- Vmux-2100 Voice cards vc2E1 (136), vc4E1 (137), vc2T1 (138), vc4T1 (139), vc2EandM (140), vc2Fxs1Plar (141), vc2Fxo1 (142), vc2Fxs2 (143), vc2Fxo2 (144), vc2Fxs3 (145), vc2Fxo3 (146), vc26EandM (147), mtvc2 (148), vc2R2Fxs (149), hsu (150), mbeA (151), mbeB (152), mbeU (153), tre (154), hsuI (155), hsr (156), hss (157), hsu1 (158), ls12 (159), ls6 (160), ls6V1EandM (161), ls6V1Fxo (162), ls6V1Fxs (163), ls6V2EandM (164), ls6V2Fxo (165), ls6V2Fxs (166), ls6VfEandM (167), ls6VfFxo (168), ls6VfFxs (169), vc3EandM (170), vc3Fxo (171), vc3Fxs (172), vcPbx (173), vcPbxT1 (174), vcPbxE1 (175), vc6EandM (176), vc6Fxo (177), vc6Fxs (178), vcq (179), ls6n (180), -- -- Packet Cards of Maxcess and Hybrid -- -- High speed cards mhs1V36 (181), mhs1V35 (182), mhs1G703 (183), mhs1DDS (184), mhs3 (185), mhs1X21 (186), mhs1V24 (187), mhs4 (188), mhsE1Hs (189), mhsT1Hs (190), mhsHyE1Hs (191), -- 2 HS ports + 1 Hybrid E1 port mhsHyT1Hs (192), -- 2 HS ports + 1 Hybrid T1 port mlfHybE1Hs (193), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid E1 port mlfHybT1Hs (194), -- Fiber Optic Hybrid: 2 HS + 1 Hybrid T1 port -- T1/E1 cards mhs2e1 (195), mhs2t1 (196), mhsHy2e1 (197), -- 2 Hybrid E1 ports mhsHy2t1 (198), -- 2 Hybrid T1 ports mlfHybE12 (199), -- Fiber Optic Hybrid: 2 E1 ports -- Low speed cards mls6 (200), mls3 (201), -- More T1/E1 cards mlHybAtmE1 (202), -- Hybrid ATM E1 mlHybAtmT1 (203), -- Hybrid ATM T1 mlfHybT12 (204), -- Fiber Optic Hybrid: 2 T1 ports -- Voice cards mvc8 (205), -- MVC-8 name in marketing: MVC-4N mvc8PbxE1 (206), mvc8PbxT1Dsu (207), mvc8PbxT1Csu (208), mvc8PbxE1Slave (209), mvc4 (210), mvc4PbxE1 (211), mvc4PbxT1Dsu (212), mvc4PbxT1Csu (213), mvc4PbxE1Slave (214), mvc4PbxT1Slave (215), mvc8PbxT1Slave (216), -- MVC-8 T1 Slave is here mvc8ExtAnalog (217), -- MVC-8 with 8 External ports mvcE1 (218), -- 8 External ports & 30 Internals mvcT1 (219), -- 8 External ports & 24 Internals -- ISDN for Maxcess mhsS (220), mhsU (221), mhsPriE1 (222), mhsPriT1 (223), -- Card of MP-2100/4 hsEthSwitch (224), -- CCS for Maxcess & MPH mPriE1FramerCcs (225), mPriT1FramerCcs (226), mpriE1SlaveCcs (227), mpriT1SlaveCcs (228), mDualBri (229), -- Voice cards for MP vc12EandM (230), vc12Fxo (231), vc12Fxs (232), vc6aEandM (233), vc6aFxo (234), vc6aFxs (235), vc6AgFxo (236), vc6AgFxs (237), vc6a4LB (238), -- Video card for MP vid (239), -- ISDN cards for MP hsu12 (240), hsu6 (241), hss12 (242), hss6 (243), -- MPH and MP-2100/4 cards hsDp3 (244), hsDp6 (245), -- MP-2100/4 card hsf1 (246), -- More Hybrid cards + IP cards for MPH mhsHyE1 (247), -- 1 Hybrid E1 port mhsHyT1 (248), -- 1 Hybrid T1 port mhsIp (249), -- 1 Eth port + 1 HS port mlIpHs (250), -- 1 Eth port + 3 HS ports mlHybIpE1 (251), -- 1 Eth port + 1 HS port + 1 E1 mlHybIpT1 (252), -- 1 Eth port + 1 HS port + 1 T1 -- VOIP cards for MPH & MX mvg1Lan (253), mvg2Lan (254), -- MP-2100/4 card vc4Fxs (255), vc4EandM (256), vc4Fxo (257), hsf2 (258), -- More VOIP cards for MPH mvgSwitch4Lan (260), -- SHDSL cards of Megaplex msl4E1W2 (261), msl4E1W4 (262), msl8E1W2 (263), msl4E1W2Eth (264), msl8E1W2Eth (265), asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH) asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH) asmi54c (268), -- & LRS-102 (ETH only) -- HS cards of Megaplex hs6N (271), hs12N (272), hsNRZ (273), -- Vmux 2100 Enhanced Voice Cards evc2E1 (281), evc4E1 (282), evc2T1 (283), evc4T1 (284), -- Vmux-2200 Voice cards vc2E1Pri (285), vc4E1Pri (286), -- MP Voice cards vc4OmniEandM (291), vc4OmniWestern (292), -- MP-4100 and/or LRS-102 cards clx1 (301), clx1GbE (302), clx1S155 (303), clx1S155GbE (304), ml8T1Eth (305), ml8E1Eth (306), op106cEth (307), -- no external T1 op108cEth (308), -- no external E1 op106cEthT1 (309), -- with external T1 (used also by LRS-102) op108cEthE1 (310), -- with external E1 (used also by LRS-102) op108cEthE1Unbal (311), -- used only by LRS-102 mpw1 (312), op34c (313), -- no external E1 op25c (314), -- no external T1 op34cE1 (315), -- with external E1 (used also by LRS-102) op25cT1 (316), -- with external T1 (used also by LRS-102) m16e1 (317), m16t1 (318), op108cE1Unbal (319), -- used only by LRS-102 op108cE1Bal (320), -- used only by LRS-102. -- VFS cards of Megaplex vfs24T1 (321), vfs30E1 (322), vfs48T1 (323), -- 2T1 vfs60E1 (324), -- 2E1 -- MiniCVS cards: This is a placeholder. The following cards exist only in the mdlSInstCardType. -- mm4E1 (325), -- mm4T1 (326), -- mm8E1 (327), -- mm8T1 (328), -- mm12E1 (329), -- mm12T1 (330), -- mm16E1 (331), -- mm16T1 (332), -- More MP-4100 / LRS-102 SDHSL Cards asmi54cE1N (340), -- E1 only New Hardware asmi54cN (341), -- ETH only New Hardware asmi54cHsN (342), -- V.35 only (HighSpeed) New Hardware asmi54cHsAndEthN (343), -- ETH & V.35 (HighSpeed) New Hardware -- MP4100 R3.0 cards cl2n (350), -- CL.2 cl2GbE (351), -- CL.2-GbE cl2s622 (352), -- CL.2-622 cl2s622GbE (353), -- CL.2-622GbE cl2s622GbEa (354), -- CL.2-622GbE/a with Advanced ETH features cl2GbEa (355), -- CL.2-GbE a with Advanced ETH features cl2ds0 (356), -- CL.2 with DS0 cross connect capabilities only -- MP4104 cards (horizontal , low cost hub, lowprofile panels ) cl2nl (360), -- CL.2 cl2GbEl (361), -- CL.2-GbE cl2s622l (362), -- CL.2-622 cl2s622GbEl (363), -- CL.2-622GbE cl2s622GbEal (364), -- CL.2-622GbE/a with Advanced ETH features cl2GbEal (365), -- CL.2-GbE a with Advanced ETH features cl2ds0l (366), -- CL.2 with DS0 cross connect capabilities only -- MP4100 R3.1 cards mEth6 (370), -- M-ETH6 Card mEth8 (371), -- M-ETH8 Card -- TeleProtection Module mTp (372), -- TeleProtection module -- MP4100 R3.4 cards mT3 (373), -- M-T3 DS3 mEthPoe (374), -- M-ETH8 with Power Over Ethernet support. -- MP4100 R4.5 cards -- X Module based cards mp4mSh16 (381), -- MP-4M-SH-16 mp4mVs12 (382), -- MP-4M-VS-12 mp4mVs6s37 (383), -- MP-4M-VS-6/37 mp4mVs6Bin (384), -- MP-4M-VS-6/BIN mp4mVs6E1T1 (385), -- MP-4M-VS-6/E1T1 mp4mE1T1 (386), -- MP-4M-E1T1 mp4mT3 (387), -- MP-4M-T3 mp4mVs6Fxs (388), -- MP-4M-VS6-FXS mp4mVs6Fxo (389), -- MP-4M-VS6-FXO mp4mVs6Em (390), -- MP-4M-VS6-EM mp4mFxsEm (391), -- MP-4M-FXS-EM -- MP4100 R4.7 cards mp4mshE1 (392), -- MP-4M-SH-E1 mp4mshE1Pw (393), -- MP-4M-SH-E1-PW mp4mvs16E1Eop (394), -- MP-4M-VS-16E1/EOP mp4mvs16T1Eop (395), -- MP-4M-VS-16T1/EOP mp4mvs16E1Pw (396), -- MP-4M-VS-16E1/PW mp4mvs16T1Pw (397), -- MP-4M-VS-16T1/PW mp4mvs6S8E1Pw (398), -- MP-4M-VS-6S/8E1/PW mp4mvs6S8T1Pw (399), -- MP-4M-VS-6S/8T1/PW -- Virtual Entity ( x.86 Module ) mp4mDnfv1 (401), -- MP-4M-DNFV-1 virtual entity (X.86 module) --MP4100 R4.9 cards mp4mvsG703 (411), -- MP-4M-VS-G703 mp4mVs6FxsPwAcr (412), -- MP-4M-VS6-FXS-PW-ACR mp4mVs6FxoPwAcr (413), -- MP-4M-VS6-FXO-PW-ACR mp4mVs6EmPwAcr (414) -- MP-4M-VS6-EM-PW-ACR } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the type of card assigned to the specific slot in the common configuration. This object is identical in all the configurations (1..100). Only the TmpCnf(255) may have different value. The write operation is valid only to the TmpCnfg entry." ::= { mdlCPrgEntry 3} mdlCNoOfExternPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of external ports in the programmed card of the specific slot position" ::= { mdlCPrgEntry 4} mdlCNoOfInternPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of internal ports in the programmed card of the specific slot position." ::= { mdlCPrgEntry 5} mdlCWorkMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), standAlone (2), integrated (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Working mode of the card. The user may configure the card to work in a stand alone mode or integrated with the device. Example for use in MHS-IP cards: - standAlone - in this mode, the router works so that data is received via the LAN (Eth) port and is transmitted via the WAN (HS) external port without going through the MPH device. - integrated - in this mode, the router works so that it is integrated in the MPH and routes DLCIs into the device." ::= { mdlCPrgEntry 6} mdlCDhcpClientEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable the feature of DHCP Client for the selected card." ::= { mdlCPrgEntry 7} mdlCRdnExists OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates whether any port of the programmed card is configured to be part of a Redundancy/APS pair. If at least one port of the programmed card is configured to be part of a Redundancy/APS pair, the value will be 'yes'. Otherwise, it will be 'no'." ::= { mdlCPrgEntry 8} mdlCInterfaces OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Octet string which indicates 'present' interfaces in card. Each '0' bit stands for non-present interface. Each '1' bit stands for present interface. For ASMi54C card of LRS-102 and MP-4100 notPresent interfaces may be: - SHDSL Line ID with no wire pairs assigned to it (does not exist in ifTable) - PCS without SHDSL Line binded to it, (exist in ifTable, with ifOperStatus= notPresent) - External DS1 when its LIU is used by an Internal DS1 of the same card - Internal DS1 when single bearer is not TDM. In each octet, MS bit represents port 1 and LS bit represents port 8 MSB LSB 1 0 0 0 1 0 0 0 -- Example: Port # 1 and 5 are present. Port 1 2 3 4 5 6 7 8 1st Octet (MSB octet) represents SDHSL Lines 2nd Octet represents PCS 3rd Octet represents External DS1 4th Octet represents Internal DS1 5th and 6th Octets are reserved for future Internal DS1. For OP-108/106 cards of LRS-102 and MP-4100 notPresent interfaces may be: - External DS1 when its 'associated' Int-DS1 port is connected to another card - Internal DS1 when its 'associated' Ext-DS1 port is connected to another card (Both may be 'present' when inter-connected). 1st Octet represents External DS1 2nd Octet represents Internal DS1 Bit representation, same as for ASMi-54C card. " ::= { mdlCPrgEntry 9 } -- -- Compressed information. -- -- Specially for RadView management station -- mdlCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprMdlGen 1 } mdlCmprEntry OBJECT-TYPE SYNTAX MdlCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlCmprTypIdx, mdlCmprCnfgIdx ,mdlCmprVersion,mdlCmprSltIdx } ::= {mdlCmprTable 1} MdlCmprEntry ::= SEQUENCE { mdlCmprTypIdx Integer32, mdlCmprCnfgIdx Integer32, mdlCmprVersion Integer32, mdlCmprSltIdx INTEGER, mdlCmprObj OCTET STRING } mdlCmprTypIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Type of the Compressed being referred." ::= { mdlCmprEntry 1} mdlCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the configuration to which the Compressed information is related." ::= { mdlCmprEntry 2} mdlCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { mdlCmprEntry 3} mdlCmprSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid." ::= { mdlCmprEntry 4} mdlCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { mdlCmprEntry 5} -- Compressed Alarm table at Card level -- The only way of reading this table is by the command 'GET NEXT' mdlAlarmsCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {cmprMdlGen 2} mdlAlarmsCmprEntry OBJECT-TYPE SYNTAX MdlAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {mdlAlarmsCmprVersion, mdlAlarmsCmprAlarmSlot,mdlAlarmsCmprAlarmIdx} ::= {mdlAlarmsCmprTable 1} MdlAlarmsCmprEntry ::= SEQUENCE { mdlAlarmsCmprVersion Integer32, mdlAlarmsCmprAlarmSlot Integer32, mdlAlarmsCmprAlarmIdx Integer32, mdlAlarmsCmprObj OCTET STRING } mdlAlarmsCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { mdlAlarmsCmprEntry 1} mdlAlarmsCmprAlarmSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid." ::= { mdlAlarmsCmprEntry 2} mdlAlarmsCmprAlarmIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table of the agent." ::= { mdlAlarmsCmprEntry 3} mdlAlarmsCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { mdlAlarmsCmprEntry 4} -- -- Wan port status general information -- prtSInstTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSInstEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { statPrtGen 1 } prtSInstEntry OBJECT-TYPE SYNTAX PrtSInstEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtSInstSltIdx, prtSInstPrtIdx } ::= { prtSInstTable 1} PrtSInstEntry ::= SEQUENCE { prtSInstSltIdx INTEGER, prtSInstPrtIdx Integer32, prtSInstPrtType INTEGER, prtSInstIfIndex Integer32, prtSActiveStatus INTEGER, prtSAlrStatus INTEGER, prtSMaskedAlrStat INTEGER, prtSClearAlrCmd INTEGER, prtSTestMask Integer32, -- prtSTstStatus INTEGER, prtSTstCmd INTEGER, prtSTstDuration Integer32, prtSBertClrCmd INTEGER, prtSBertTstRslt Integer32, prtSInterfaceType DisplayString, prtSParamStatus OCTET STRING, prtSTestMaskXp OCTET STRING, prtSRdnStatus INTEGER } prtSInstSltIdx OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify the slot where the card is inserted. In the ?004 Unit the entries io6(10)..io(16) are not valid. For the Vmux2100 Main Board clA (3) is used." ::= { prtSInstEntry 1} prtSInstPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number to identify a port in a specific card. The valid ports depend on the installed card: the valid external ports (interfaces) are (1..mdlCNoOfExternPrt) if any, and the valid internal ports are (101..100+mdlCNoOfInternPrt) if any. Generally, for MP-2100/2200: exPrt1 (1) .. exPrt16 (16),inPrt1(101) .. inPrt48 (148) For the Vmux-2100 device: This index will have values of 1...4 for the physical ports & values of ifIndex for the bundles. For other products, see product's spec." ::= { prtSInstEntry 2} prtSInstPrtType OBJECT-TYPE SYNTAX INTEGER { external (2), internal (3), highSpeedV35 (4), highSpeedV24 (5), highSpeedV36 (6), highSpeedX21 (7), highSpeedG703 (8), highSpeedDDS (9), lowSpeed (10), voice (11), cl (12), isdns (13), isdnu (14), ethernet (15), voiceS0 (16), voiceU (17), voiceQsigS (18), voiceQsigU (19) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute describes the type of the designated port. In MX 3000 only external & internal options are used. All the other options are only for MX 30/300 which need special handling. In order to support interface types in MX 3000, return an ascii string for prtSInterfaceType in this table or support the general RAD value of physicalConnector. External port - is a port with a physical connector. Internal port - might be of two types: a) A composite port which collects a few external ports data into a common bandwidth (usually routed through DS1 link) b) A port which gets only part of the external ports (usually a few DS0's) The following types are used when all ports are external/ internal and the connector/interface type is necessary (for example, stand-alone units): High Speed port types Low Speed port types Voice port types, CL port types. ISDN Voice in MX 30/300 Phase 4: voiceS0 (16), voiceU (17) should be used. ISDN Voice in MX 30/300 Phase 5: voiceQsigS(18), voiceQsigU (19) should be used." ::= { prtSInstEntry 3} prtSInstIfIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the unique interface number assigned to the port. The specific interface of this attribute is the same as the interface identified by the value of ifindex in MIB-II.If there is no interface for the specific prtIdx the value will be '7fffffff'h." ::= { prtSInstEntry 4} prtSActiveStatus OBJECT-TYPE SYNTAX INTEGER { unknown (1), notUsed (2), offLine (3), onLine (4), offLineRedundancy (5), onLineRedundancy (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute describes the activity status of the port. unknown(1) indicates that the information is not supported. notUsed(2) indicates that the ch is not connected according to the active config. offLine(3) indicates that the ch is down (not working) because of any problem. onLine(4) indicates that the ch is up (working) offLineRedundancy(5) indicates that the ch is down, because it is redundant port. onLineRedundancy(6) indicates that the ch is up, and it is the active link" ::= { prtSInstEntry 5} prtSAlrStatus OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the port(ch) agent level. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= { prtSInstEntry 6} prtSMaskedAlrStat OBJECT-TYPE SYNTAX INTEGER { off (2), event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the alarm state in the port(ch) agent level, including Masked alarms. This attribute will be set to: critical(7) - when there is at least one active (state ON) critical alarm, otherwise it will be set to major(5) - when there is at least one active (state ON) major alarm, otherwise it will be set to minor(4) - if there is at least one active (state ON) minor alarm, otherwise it will be set to warning(6) - if there is at least one active (state ON) warning alarm, otherwise it will be set to event(3) - if there was at least one alarm event (including state on,off events) since the last clear operation." ::= {prtSInstEntry 7} prtSClearAlrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on(3) enforces a clear operation of the alarm status events in the given port. The clear operation will not be applied for masked/inverted alarms." ::= { prtSInstEntry 8} prtSTestMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This is a mask which indicates which tests from the 'prtSTstCmd' list are allowed for the requested port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- local-loop 1 remote-loop 2 loc-and-rem-main-loops 3 remote-analog-loop 4 remote-digital-loop 5 rem-loop-on-ext-unit 6 bert 7 tone-injection 8 dlci local-loop 9 all dlci local-loop 10 dlci remote-loop 11 all dlci remote-loop 12 bert-and-rem-loop-on-rem-unit 13 rem-loop-on-rem-unit 14 block 15 backward-tone-inject 16 llb 17 rlb 18 ft1Enable 21 lbbd 22 --for 2B+D lb1 23 --for B1 lb2 24 --for B2 llb-on-rem-unit 25 bert-on-rem-unit 26 bert-on-rem-and-llb-on-rem-unit 27 local-and-bert-on-rem-unit 28 local-loop-on-rem-unit 29 localBert 30 --towards IO ports test-per-TS 31 e.g : If the return value is 3 -> 0000000000000011 -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop " ::= { prtSInstEntry 9} -- prtSTstStatus OBJECT-TYPE -- SYNTAX INTEGER -- { -- off(2), -- on (3) -- } -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- "This attribute will be set to on(3) when there is at least -- one test in progress in the port, otherwise the value -- will be off(2)." -- ::= { prtSInstEntry 10} -- prtSTstCmd OBJECT-TYPE SYNTAX INTEGER { none (1), localLoop (2), remoteLoop (3), locAndRemMainLoops (4), remoteAnalogLoop (5), remoteDigitalLoop (6), remLoopOnExtUnit (7), bert (8), toneInjection (9), dlciLocalLoop (10), allDlciLocalLoop (11), dlciRemoteLoop (12), allDlciRemoteLoop (13), extInitLocalLoop (14), bertAndRemLoopOnRemUnit (15), remLoopOnRemUnit (16), block (17), backwardToneInject (18), llb (19), rlb (20), ft1Enable (21), lbbd (22), --for 2B+D lb1 (23), --for B1 lb2 (24), --for B2 llbOnRemUnit (25), bertOnRemUnit (26), bertOnRemAndLlbOnRemUnit (27), localAndBertOnRemUnit(28), localLoopOnRemUnit (29), localBert (30), testPerTS (31), csuLoopAndBert (32), dsuLoopAndBert (33), remoteOcuLoopAndBert (34), remoteCsuLoopAndBert (35), remoteDsuLoopAndBert (36) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to any of the above values will initiate a test on the specific port if the operation is legal. If the operation is not legal, the mux will ignore the operation. testPerTS(31) - when this test is selected, the selection of tests for each TS is done via the prtExPh1MlTsTest object. If a test time out is needed, the test will be set with a default timeout of 2 minutes until the user will set the parameter 'prtSTstDuration' to the required time out. If no time out is needed , the test will be set with infinite timeout until the user will set the parameter 'prtSTstDuration' to the required time out." ::= { prtSInstEntry 10} prtSTstDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the maximum duration of executing a test on the specific port. This entry applies to all the test operations. The resolution will be a minute, and the maximum duration is limited to 30 minutes. For Vmux devices, the values are in seconds. A zero value specifies no time limitation. When the test isn't active, the agent initiates this object to 2 when the duration is needed and to 0 if its not required. The user should set this parameter after setting the 'prtSTstCmd' parameter." ::= { prtSInstEntry 11} prtSBertClrCmd OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute initiates bert count clear operation. It is valid only when bert test is active on the specific port." ::= { prtSInstEntry 12} prtSBertTstRslt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the number of Bit Error Rate indicated during the BERT operation. It is valid only when bert test is active on the specific port." ::= { prtSInstEntry 13} prtSInterfaceType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique HW interface type of the selected port." ::= { prtSInstEntry 14} prtSParamStatus OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates Status of parameters specific to the selected port. - For a port that has no special status or is supported by prtSExHsfStatTable - 1 Octet: 00hex - For VC-6, VC-6A, VC-6AG, VC-6A/4LB, VC-12, VC-12/6, external ports - 1 Octet : Bit 7 (MSB)..Bit 2 = 0 (NA) Bit 1: Tx Signaling '1'=On ; '0'=Off Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off - For VC-2/R2(FXS) external ports - 1 Octet : Bit - 7 6 5 4 3 2 1 0 |_| |_________| Call Call State Direction Bit 7 (MSB) and Bit 6 : Call Direction 00 - Incoming 01 - Outgoing Bit 5..Bit 0: Call State 000000 - Idle 000001 - Seized 000010 - Both-Way Conflict 000011 - Seizure Ack 000100 - Answered 000101 - Clear Backward 000110 - Clear Forward 000111 - Blocked 001000 - Fault 001001 - Fault 3 001010 - Fault 4 001011 - Fault 5 001100 - Fault 6 001101 - Fault 7 - For ML-20 external port - 3 Octets : - 1 MS Octet will represent the Real Rate used: Bit - 7 6 5 4 3 2 1 0 |___| |_______| spare Rate Valid values: 0..31, meaning 0..31x64Kbps Invalid values: 32..255. - 2 LS Octets will represent the Status of 7 Control Signals: Signal - --- CTS DSR DCD RJ TM DTR RTS Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Octet - 2 3 (LS) '---' will always have the value 00 Rest of the Signals (2 bits each) can have the following values: 00=NA ; 01=unused ; 10=Off ; 11=On - For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |___________| spare Mode of Operation Mode of Operation: '1'=Central ; '0'=Remote - For ACM external port - 1 Octet Bit - 7 6 5 4 3 2 1 0 |_________| spare Alarm State Alarm State: according to bits 1,0: 00=NA ; 01=unused ; 10=Off ; 11=On - For HS-U/1 external port - 1 Octet Bit 7 6 5 4 3 2 1 0 LSB |________| |__| |__| spare modem sync modem: 00 = other sync: 00 = not sync 01 = unknown 01 = sync 10 = ASMi-31/2 10 = reserved 11 = reserved 11 = reserved - For MTML-2/4 external ports, ML-8 externalports, ML-IP (MTML-IP) internal ports and MTML-E2 internal ports - 1 Octet : Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs/Bits) 1 = ON (BERT is running on this port OR on one of its TSs/Bits) - For ML-20N external ports - 4 Octets - 1 MS Octet will represent the Actual Link Rate: Bit - 7 6 5 4 3 2 1 0 |_| |_________| spare Rate Valid values: 0..34, meaning: 0..32 = (0..32)x64Kbps 33 = Invalid Rate 34 = not applicable (when Rate is not Auto) 35 = 0 Kbps Invalid values: 36..255. - 2 middle Octets will represent the Status of 4 Control Signals: - LS Octet - Bits 3-0: RTS/C (Command, for X.21 interface) Bits 7-4: DCD/I (Indication for X.21 interface) - MS Octet - Bits 3-0: DTR Bits 7-4: DSR Each 4 Bits are divided as follows: - 2 MS bits: DCE - 2 LS bits: DTE For each 2 bits (DCE/DTE): 00=NA ; 01=unused ; 10=Off ; 11=On. - LS Octet: (as for MTML-2): Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs/Bits) 1 = ON (BERT is running on this port OR on one of its TSs/Bits) - For MP-2100/2200 MSL-4/E1, MSL-8/E1 External ports - 3 Octets - MS octet: far-end modem channel interface - Middle octet: Material (plastic/metal), far-end modem type, synchronization with far-end modem - LS octet: BERT state (at port/TS/Bit level) - MS octet: 0000 0000 = no interface 0000 0001 = db15 (X21) 0000 0010 = IR-IP 0000 0011 = IR-ETH-Q 0000 0100 = V35 0000 0101 = ETH-RJ45 0000 0110 = G703 0000 0111 = db25 (RS530) 0000 1000 = ETH-BNC 0000 1001 = E1(Balanced) 0000 1010 = E1(Unbalanced) 0000 1011 = IR-ETH-QN Rest of the combinations: reserved - Middle octet: Bit 7 6 5 4 3 2 1 0 LSB | |___________| |__| Box material modem sync Box material modem: 00000 = other sync: 00 = not sync (for ASMi-52 SA) 00001 = unknown 01 = sync 0=metal 00010 = reserved 10 = reserved 1=plastic 00011 = reserved 11 = reserved 00100 = reserved 00101 = reserved 00110 = ASMi-52 SA/2W/Slave 00111 = ASMi-52 SA/2W/Master 01000 = ASMi-52/CQ card of LRS-24 01001 = ASMi-52/CD card of LRS-24 01010 = D16GSDSL card of DXC-3000 01011 = LRS-52 01100 = FCD-IP 01101 = FCD-IPM 01110 = D8SL card of DXC-30 01111 = ASMi-52A 10000 = MP card (SHDSL) 10001 = ASMi-52L Rest = reserved - LS Octet: (as for MTML-2): Bit 7 6 5 4 3 2 1 0 LSB | BERT State BERT State (Bit 0): 0 = OFF (BERT is not running on this port or any of its TSs) 1 = ON (BERT is running on this port OR on one of its TSs) - For MP-4100 MSL card Links - 4 Octets - MS octet: far-end modem DTE2 interface (same as for MP-2100 MSL cards) - after MS octet: far-end modem DTE1 interface (same as for MP-2100 MSL cards) - before LS octet: Material (plastic/metal), far-end modem type, synchronization with far-end modem (same as for MP-2100 MSL cards) - LS octet: BERT state (at port/TS/Bit level)- same as for MP-2100 MSL cards - For MP-4100, LRS-102 OP-108/106 , OP-34/25 Links - 3 Octets - MS octet: Far-End PS type and state - Middle octet: synchronization with Far-End device - LS octet: BERT state (at port/TS level) - same as for MP-2100 MSL cards - MS octet: Bit 7 6 5 4 3 2 1 0 LSB |__| |__| |__| |__| PS-A PS-A PS-B PS-B PS Type PS State PS Type PS State 00=None 00=None 01=AC-DC 01=OK 10=DC 10=Fail 11=AC - Middle octet: Bit 7 6 5 4 3 2 1 0 LSB |__| sync: 00 = not sync 01 = sync 10 = reserved 11 = reserved Rest = reserved " ::= { prtSInstEntry 15} prtSTestMaskXp OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This is an Expanded test mask of the prtSTestMask object. The prtSTestMask object reached its maximum, being an Integer with 32 bits. This object indicates which tests from the 'prtSTstCmdXP' list are allowed for the selected port. If a specific test is allowed, its respective bit will be SET in the mask : TEST BIT ----------- --- local-loop 1 remote-loop 2 loc-and-rem-main-loops 3 remote-analog-loop 4 remote-digital-loop 5 rem-loop-on-ext-unit 6 bert 7 tone-injection 8 dlci local-loop 9 all dlci local-loop 10 dlci remote-loop 11 all dlci remote-loop 12 bert-and-rem-loop-on-rem-unit 13 rem-loop-on-rem-unit 14 block 15 backward-tone-inject 16 llb 17 rlb 18 ft1Enable 21 lbbd 22 --for 2B+D lb1 23 --for B1 lb2 24 --for B2 llb-on-rem-unit 25 bert-on-rem-unit 26 bert-on-rem-and-llb-on-rem-unit 27 local-and-bert-on-rem-unit 28 local-loop-on-rem-unit 29 localBert 30 --towards IO ports test-per-TS 31 csuLoopAndBert 32 dsuLoopAndBert 33 remoteOcuLoopAndBert 34 remoteCsuLoopAndBert 35 remoteDsuLoopAndBert 36 e.g : If the return value is 00000003 hex -> Bits 1 & 2 are set -> the allowed tests are : local-loop remote-loop " ::= { prtSInstEntry 16} prtSRdnStatus OBJECT-TYPE SYNTAX INTEGER { noRdn (1), offline(2), online (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Redundancy Status of this port. noRdn - this port is not part of a Redundancy pair/group. offline - this port is offline from Redundancy point of view. online - this port is online from Redundancy point of view." ::= { prtSInstEntry 17} prtSAlrTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The list of port agent alarms." ::= { statPrtGen 2 } prtSAlrEntry OBJECT-TYPE SYNTAX PrtSAlrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtSAlrSltIdx, prtSAlrPrtIdx, prtSAlrIdx} ::= { prtSAlrTable 1} PrtSAlrEntry ::= SEQUENCE { prtSAlrSltIdx INTEGER, prtSAlrPrtIdx Integer32, prtSAlrIdx Integer32, prtSAlrCodeDescription DisplayString, prtSAlrCode Integer32, prtSAlrSeverity INTEGER, prtSAlrState INTEGER, prtSAlrCounter Integer32, prtSAlrMask INTEGER, prtSAlrInvert INTEGER, prtSAlrCardType INTEGER } prtSAlrIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table. Users should use the get next function to read this table because the indexes are not consecutive" ::= { prtSAlrEntry 1} prtSAlrSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the slot where the card is inserted. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io12(16) are not valid. For the Vmux2100 Main Board clA (3) is used." ::= { prtSAlrEntry 2} prtSAlrPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a port which does not exist. Valid valuesfor MP-2100/2200: exPrt1 (1) .. exPrt16 (16) , inPrt1 (101) .. inPrt48 (148), IP Bundles. For other products, see product's spec." ::= { prtSAlrEntry 3} prtSAlrCodeDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is a full text description of the alarm. The alarm description includes the following information: alarm code, alarm text, alarm severity, Masked or Inverted flag and counter." ::= { prtSAlrEntry 4} prtSAlrCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A code identifying the alarm of an entry in the alarm status table at port level." ::= { prtSAlrEntry 5 } prtSAlrSeverity OBJECT-TYPE SYNTAX INTEGER { event (3), minor (4), major (5), warning (6), critical (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The severity of the alarm." ::= { prtSAlrEntry 6 } prtSAlrState OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "State of the alarm." ::= { prtSAlrEntry 7 } prtSAlrCounter OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A counter - how many times the alarm occured since last clear operation. ON and OFF Alarm will be counted separately." ::= { prtSAlrEntry 8 } prtSAlrMask OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm mask : on/off." ::= { prtSAlrEntry 9 } prtSAlrInvert OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm invert : on/off." ::= { prtSAlrEntry 10 } prtSAlrCardType OBJECT-TYPE SYNTAX INTEGER { -- -- General types -- unknown (1), empty (2), -- -- Power Supply Modules -- ps (17), -- -- Cl Modules -- cl1 (20), cl1Clk (26), --CL1 with Station Clock (for LRS102) -- VF cards of Megaplex vf24T1 (62), vf30E1 (63), vf48T1 (64), vf60E1 (65), -- -- TDM Cards -- vc8EandM (74), vc8Fxo (75), vc8Fxs (76), vc16EandM (77), vc16Fxo (78), vc16Fxs (79), ml8T1 (134), ml8E1 (135), hsr (156), ls12 (159), ls6n (180), hsEthSwitch (224), hsu12 (240), hsu6 (241), vc4Fxs (255), vc4EandM (256), vc4Fxo (257), msl4E1W2 (261), msl8E1W2 (263), msl4E1W2Eth (264), msl8E1W2Eth (265), asmi54cE1AndEth (266), -- & LRS-102 (E1 & ETH) asmi54cT1AndEth (267), -- & LRS-102 (T1 & ETH) asmi54c (268), -- & LRS-102 (ETH only) hs6N (271), hs12N (272), -- MP-4100 (and LRS-102) cards clx1 (301), clx1GbE (302), clx1S155 (303), clx1S155GbE (304), ml8T1Eth (305), ml8E1Eth (306), op106cEth (307), --no external T1 op108cEth (308), --no external E1 op106cEthT1 (309), --with external T1 (used also by LRS-102) op108cEthE1 (310), --with external E1 (used also by LRS-102) op108cEthE1Unbal(311), --used only by LRS-102 mpw1 (312), -- VFS cards of Megaplex vfs24T1 (321), vfs30E1 (322), vfs48T1 (323), --2T1 vfs60E1 (324) --2E1 } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the type of card installed in the specific slot position. The enumeration is according to mdlSInstCardType." ::= { prtSAlrEntry 11 } -- -- Statistics of Ports -- --statisPrtGen OBJECT IDENTIFIER ::= {statPrtGen 3} --prtFrStatis OBJECT IDENTIFIER ::= {statisPrtGen 1} --prtCrStatis OBJECT IDENTIFIER ::= {statisPrtGen 2} --prtDlciStatis OBJECT IDENTIFIER ::= {statisPrtGen 3} --prtT1Statis OBJECT IDENTIFIER ::= {statisPrtGen 4} --prtFrStatis - Port Statistics for (FR) Frame Relay protocol prtFrStatisTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtFrStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is applicable only for an active port running an FR protocol ." ::= { prtFrStatis 1} prtFrStatisEntry OBJECT-TYPE SYNTAX PrtFrStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtFrStatisSltIdx, prtFrStatisPrtIdx, prtFrStatisInvIdx} ::= { prtFrStatisTable 1} PrtFrStatisEntry ::= SEQUENCE { prtFrStatisSltIdx INTEGER, prtFrStatisPrtIdx INTEGER, prtFrStatisInvIdx INTEGER, prtFrTimeElapsed Integer32, prtFrRxTotalFrames Counter32, prtFrTxTotalFrames Counter32, prtFrRxTotalBytes Counter32, prtFrTxTotalBytes Counter32, prtFrRxMngFrames Counter32, prtFrTxMngFrames Counter32, prtFrRxDeFrames Counter32, prtFrTxDeFrames Counter32, prtFrRxDcrdCongDeFr Counter32, prtFrTxDcrdCongDeFr Counter32, prtFrRxDcrdCongAllFr Counter32, prtFrTxDcrdCongAllFr Counter32, prtFrRxFecn Counter32, prtFrTxFecn Counter32, prtFrRxBecn Counter32, prtFrTxBecn Counter32, prtFrRxBeViol Counter32, prtFrTxBeViol Counter32, prtFrRxBcViol Counter32, prtFrTxBcViol Counter32 } prtFrStatisSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255)." ::= { prtFrStatisEntry 1} prtFrStatisPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtFrStatisEntry 2} prtFrStatisInvIdx OBJECT-TYPE SYNTAX INTEGER { currentInv (1), last (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Interval of 15 min. for which the following statistics counters are applicable." ::= { prtFrStatisEntry 3} prtFrTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0." ::= { prtFrStatisEntry 4 } prtFrRxTotalFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames received by this port during the selected interval." ::= { prtFrStatisEntry 5 } prtFrTxTotalFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of frames sent by this port during the selected interval." ::= { prtFrStatisEntry 6 } prtFrRxTotalBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of bytes received by this port during the selected interval." ::= { prtFrStatisEntry 7 } prtFrTxTotalBytes OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of bytes sent by this port during the selected interval." ::= { prtFrStatisEntry 8 } prtFrRxMngFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The management number of frames received by this port during the selected interval." ::= { prtFrStatisEntry 9 } prtFrTxMngFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The management number of frames sent by this port during the selected interval." ::= { prtFrStatisEntry 10 } prtFrRxDeFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames received by this port during the selected interval." ::= { prtFrStatisEntry 11 } prtFrTxDeFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames sent by this port during the selected interval." ::= { prtFrStatisEntry 12 } prtFrRxDcrdCongDeFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames discarded due to congestion, received by this port during the selected interval." ::= { prtFrStatisEntry 13 } prtFrTxDcrdCongDeFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames discarded due to congestion, sent by this port during the selected interval." ::= { prtFrStatisEntry 14 } prtFrRxDcrdCongAllFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "All the frames discarded due to congestion, received by this port during the selected interval." ::= { prtFrStatisEntry 15 } prtFrTxDcrdCongAllFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "All the frames discarded due to congestion, sent by this port during the selected interval." ::= { prtFrStatisEntry 16 } prtFrRxFecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames received by this port during the selected interval, indicating forward congestion." ::= { prtFrStatisEntry 17 } prtFrTxFecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames sent by this port during the selected interval, indicating forward congestion." ::= { prtFrStatisEntry 18 } prtFrRxBecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames received by this port during the selected interval, indicating backward congestion." ::= { prtFrStatisEntry 19 } prtFrTxBecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames sent by this port during the selected interval, indicating backward congestion." ::= { prtFrStatisEntry 20 } prtFrRxBeViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames received by this port during the selected interval, exceeding the Burst Excess value." ::= { prtFrStatisEntry 21 } prtFrTxBeViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames sent by this port during the selected interval, exceeding the Burst Excess value." ::= { prtFrStatisEntry 22 } prtFrRxBcViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames received by this port during the selected interval, exceeding the Burst Committed value." ::= { prtFrStatisEntry 23 } prtFrTxBcViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames sent by this port during the selected interval, exceeding the Burst Committed value." ::= { prtFrStatisEntry 24 } --prtCrStatis - Port Statistics for (CR) Cell Relay protocol prtCrStatisTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtCrStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is applicable only for an active port running a CR protocol ." ::= { prtCrStatis 1} prtCrStatisEntry OBJECT-TYPE SYNTAX PrtCrStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtCrStatisSltIdx, prtCrStatisPrtIdx, prtCrStatisInvIdx} ::= { prtCrStatisTable 1} PrtCrStatisEntry ::= SEQUENCE { prtCrStatisSltIdx INTEGER, prtCrStatisPrtIdx INTEGER, prtCrStatisInvIdx INTEGER, prtCrTimeElapsed Integer32, prtCrRxTotalCells Counter32, prtCrTxTotalCells Counter32, prtCrRxDataCells Counter32, prtCrTxDataCells Counter32 } prtCrStatisSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255)." ::= { prtCrStatisEntry 1} prtCrStatisPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtCrStatisEntry 2} prtCrStatisInvIdx OBJECT-TYPE SYNTAX INTEGER { currentInv (1), last (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Interval of 15 min. for which the following statistics counters are applicable." ::= { prtCrStatisEntry 3} prtCrTimeElapsed OBJECT-TYPE SYNTAX Integer32 (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the current error-measurement interval. This object is applicable mainly for the current interval. For other interval: - if data is available: value will be 899. - if data is not available: value will be 0." ::= { prtCrStatisEntry 4 } prtCrRxTotalCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of cells received by this port during the selected interval." ::= { prtCrStatisEntry 5 } prtCrTxTotalCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of cells sent by this port during the selected interval." ::= { prtCrStatisEntry 6 } prtCrRxDataCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Data Cells received by this port during the selected interval." ::= { prtCrStatisEntry 7 } prtCrTxDataCells OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Data Cells sent by this port during the selected interval." ::= { prtCrStatisEntry 8 } --prtDlciStatis - Port DLCI Statistics for FR, FR+ and CR protocol prtDlciStatisTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDlciStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is applicable only for an active port running an FR, FR+ or CR protocol, with valid DLCIs ." ::= { prtDlciStatis 1} prtDlciStatisEntry OBJECT-TYPE SYNTAX PrtDlciStatisEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtDlciSltIdx, prtDlciPrtIdx, prtDlciIdx} ::= { prtDlciStatisTable 1} PrtDlciStatisEntry ::= SEQUENCE { prtDlciSltIdx INTEGER, prtDlciPrtIdx INTEGER, prtDlciIdx Integer32, prtDlciRxDeFrames Counter32, prtDlciTxDeFrames Counter32, prtDlciRxDcrdCongDeFr Counter32, prtDlciTxDcrdCongDeFr Counter32, prtDlciRxDcrdCongAllFr Counter32, prtDlciTxDcrdCongAllFr Counter32, prtDlciTxFecn Counter32, prtDlciTxBecn Counter32, prtDlciRxBeViol Counter32, prtDlciTxBeViol Counter32, prtDlciRxBcViol Counter32, prtDlciTxBcViol Counter32 } prtDlciSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For stand-alone units this index will be notApplicable (255)." ::= { prtDlciStatisEntry 1} prtDlciPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtDlciStatisEntry 2} prtDlciIdx OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique DLCI index for each valid DLCI (16..991). " ::= { prtDlciStatisEntry 3} prtDlciRxDeFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames received by this DLCI." ::= { prtDlciStatisEntry 4 } prtDlciTxDeFrames OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames sent by this DLCI." ::= { prtDlciStatisEntry 5 } prtDlciRxDcrdCongDeFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames discarded due to congestion, received by this DLCI." ::= { prtDlciStatisEntry 6 } prtDlciTxDcrdCongDeFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of De frames discarded due to congestion, sent by this DLCI." ::= { prtDlciStatisEntry 7 } prtDlciRxDcrdCongAllFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "All the frames discarded due to congestion, received by this DLCI." ::= { prtDlciStatisEntry 8 } prtDlciTxDcrdCongAllFr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "All the frames discarded due to congestion, sent by this DLCI." ::= { prtDlciStatisEntry 9 } prtDlciTxFecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames sent by this DLCI, indicating forward congestion." ::= { prtDlciStatisEntry 10 } prtDlciTxBecn OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of frames sent by this DLCI, indicating backward congestion." ::= { prtDlciStatisEntry 11 } prtDlciRxBeViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames received by this DLCI, exceeding the Burst Excess value." ::= { prtDlciStatisEntry 12 } prtDlciTxBeViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames sent by this DLCI, exceeding the Burst Excess value." ::= { prtDlciStatisEntry 13 } prtDlciRxBcViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames received by this DLCI, exceeding the Burst Committed value." ::= { prtDlciStatisEntry 14 } prtDlciTxBcViol OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of data frames sent by this DLCI, exceeding the Burst Committed value." ::= { prtDlciStatisEntry 15 } --prtT1 Last FDL Message Table - Statistics prtT1FdlMsgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtT1FdlMsgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table is applicable for a T1 interface with 'esf' LineType ." ::= { prtT1Statis 1} prtT1FdlMsgEntry OBJECT-TYPE SYNTAX PrtT1FdlMsgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtT1FdlMsgSltIdx, prtT1FdlMsgPrtIdx, prtT1FdlMsgFdlTxRx} ::= { prtT1FdlMsgTable 1} PrtT1FdlMsgEntry ::= SEQUENCE { prtT1FdlMsgSltIdx INTEGER, prtT1FdlMsgPrtIdx INTEGER, prtT1FdlMsgFdlTxRx INTEGER, prtT1FdlMsg OCTET STRING } prtT1FdlMsgSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= { prtT1FdlMsgEntry 1} prtT1FdlMsgPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. MTML-1/T1 modules have just one external interface." ::= { prtT1FdlMsgEntry 2} prtT1FdlMsgFdlTxRx OBJECT-TYPE SYNTAX INTEGER { tx (1), rx (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Fdl tx/rx reference of the Fdl message." ::= { prtT1FdlMsgEntry 3} prtT1FdlMsg OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "FDL message." ::= { prtT1FdlMsgEntry 4} -- -- Extension of the Time Slot Config Table of ML ports -- -- Time Slot is split to 8 Bits prtExTsSplitTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExTsSplitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry, except prtExTsBitTest that will be written directly to the Active Configuration." ::= {cnfgPrtGen 1} prtExTsSplitEntry OBJECT-TYPE SYNTAX PrtExTsSplitEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExTsCnfgIdx, prtExTsSltIdx, prtExTsPrtIdx, prtExTsIdx, prtExTsBit} ::= { prtExTsSplitTable 1} PrtExTsSplitEntry ::= SEQUENCE { prtExTsCnfgIdx Integer32, prtExTsSltIdx INTEGER, prtExTsPrtIdx Integer32, prtExTsIdx Integer32, prtExTsBit Integer32, prtExTsIConSlot INTEGER, prtExTsIConPrt Integer32, prtExTsBitTest INTEGER, prtExTsTxSignaling OCTET STRING, prtExTsRxSignaling OCTET STRING, prtExTsTxIoSignaling OCTET STRING, prtExTsRxIoSignaling OCTET STRING } prtExTsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExTsSplitEntry 1} prtExTsSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units." ::= { prtExTsSplitEntry 2} prtExTsPrtIdx OBJECT-TYPE SYNTAX Integer32 -- For MP: -- { -- exPrt1 (1), -- inPrt1 (101) -- } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. Most ML cards have only one external interface. inPrt1 - for MTML-H/E1 cards. For other products' index see their specification." ::= { prtExTsSplitEntry 3} prtExTsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling." ::= { prtExTsSplitEntry 4} prtExTsBit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique Bit within the time slot. The valid Bits are: 1..8. 255=NA." ::= { prtExTsSplitEntry 5} prtExTsIConSlot OBJECT-TYPE SYNTAX INTEGER { noConnect (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - for stand-alone units." ::= {prtExTsSplitEntry 6} prtExTsIConPrt OBJECT-TYPE SYNTAX Integer32 -- For MP: -- { -- exPrt1 (1) , -- exPrt2 (2) , -- exPrt3 (3) , -- exPrt4 (4) , -- exPrt5 (5) , -- exPrt6 (6) , -- exPrt7 (7) , -- exPrt8 (8) , -- exPrt9 (9) , -- exPrt10 (10) , -- exPrt11 (11) , -- exPrt12 (12) , -- -- noConnect (100), -- -- inPrt1 (101) , -- inPrt2 (102) , -- inPrt3 (103) , -- inPrt4 (104) , -- inPrt5 (105) , -- inPrt6 (106) , -- inPrt7 (107) , -- inPrt8 (108) , -- inPrt9 (109) , -- inPrt10 (110) , -- inPrt11 (111) , -- inPrt12 (112) -- } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the internally (In Mux) connected/routed port. For other products' index see their specification." ::= {prtExTsSplitEntry 7} prtExTsBitTest OBJECT-TYPE SYNTAX INTEGER { none (1), remoteBert (8), localBert (30), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a test to be activated on the selected Bit. It is applicable only when prtExPh1MlTsTest=split(254). none - no test is applied for the selected Bit. notApplicable - when prtExPh1MlTsTest is NOT split(254)." ::= { prtExTsSplitEntry 8} prtExTsTxSignaling OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Link - Tx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is sent to Link for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA" ::= { prtExTsSplitEntry 9} prtExTsRxSignaling OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Link - Rx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is received from Link for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA" ::= { prtExTsSplitEntry 10} prtExTsTxIoSignaling OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "IO - Tx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is sent to IO port for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA" ::= { prtExTsSplitEntry 11} prtExTsRxIoSignaling OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "IO - Rx Signaling per TS, for TSs having TS Type=Voice (agnTsType=voice(2)). It monitors what is received from IO port for the selected TS, for A,B,C,D Signaling Bits. Bit 1= LSB Bit 8= MSB Bit 1-2 = A Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 3-4 = B Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 5-6 = C Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA Bit 7-8 = D Signaling Bit: 00='0' ; 01='1' ; 10=not used ; 11=NA" ::= { prtExTsSplitEntry 12} prtCnfgAgenda OBJECT IDENTIFIER ::= {cnfgPrtGen 2} prtAgendaBehaviourTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtAgendaBehaviourEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtCnfgAgenda 1} prtAgendaBehaviourEntry OBJECT-TYPE SYNTAX PrtAgendaBehaviourEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtAgendaBehaviourCnfgIdx, prtAgendaBehaviourSltIdx, prtAgendaBehaviourPrtIdx } ::= { prtAgendaBehaviourTable 1} PrtAgendaBehaviourEntry ::= SEQUENCE { prtAgendaBehaviourCnfgIdx Integer32, prtAgendaBehaviourSltIdx Integer32, prtAgendaBehaviourPrtIdx Integer32, prtAgendaBehaviourOnOff INTEGER } prtAgendaBehaviourCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtAgendaBehaviourEntry 1} prtAgendaBehaviourSltIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter should be: - slot number for MX3000 - 255 = N/A for MX300/30. " ::= { prtAgendaBehaviourEntry 2 } prtAgendaBehaviourPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter should be: - port number for MX300/30 - 100 = N/A for MX3000. " ::= { prtAgendaBehaviourEntry 3 } prtAgendaBehaviourOnOff OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this command to on(3) enables the agenda function at module (3000) or port (300/30) level." DEFVAL { off } ::= { prtAgendaBehaviourEntry 4 } prtCnfgAgendaTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtCnfgAgendaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table allows the user to schedule the time a session is active per week basis." ::= { prtCnfgAgenda 2} prtCnfgAgendaEntry OBJECT-TYPE SYNTAX PrtCnfgAgendaEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtCnfgAgendaCnfgIdx, prtCnfgAgendaSltIdx, prtCnfgAgendaPrtIdx, prtCnfgAgendaDayIdx, prtCnfgAgendaSesId } ::= { prtCnfgAgendaTable 1} PrtCnfgAgendaEntry ::= SEQUENCE { prtCnfgAgendaCnfgIdx Integer32, prtCnfgAgendaSltIdx Integer32, prtCnfgAgendaPrtIdx Integer32, prtCnfgAgendaDayIdx INTEGER, prtCnfgAgendaSesId Integer32, prtCnfgAgendaFrom Integer32, prtCnfgAgendaTo Integer32 } prtCnfgAgendaCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtCnfgAgendaEntry 1} prtCnfgAgendaSltIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is equal to: -slot number for MX3000 -255 = N/A for MX300/30" ::= { prtCnfgAgendaEntry 2} prtCnfgAgendaPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is equal to: - port number for MX300/30 - port number for MX3000. For example 1-4 in MHS-4 cards. - 100 = N/A for MX3000 when not used." ::= { prtCnfgAgendaEntry 3} prtCnfgAgendaDayIdx OBJECT-TYPE SYNTAX INTEGER { monday (1), tuesday (2), wednesday(3), thursday (4), friday (5), saturday (6), sunday (7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute for which day of the week this row applies." ::= { prtCnfgAgendaEntry 4 } prtCnfgAgendaSesId OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "The user may define 4 different active intervals per day." ::= { prtCnfgAgendaEntry 5 } prtCnfgAgendaFrom OBJECT-TYPE SYNTAX Integer32 (0..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "Start from time interval in seconds." DEFVAL {86400} ::= { prtCnfgAgendaEntry 6 } prtCnfgAgendaTo OBJECT-TYPE SYNTAX Integer32 (0..86400) MAX-ACCESS read-write STATUS current DESCRIPTION "To time interval in seconds." DEFVAL {86400} ::= { prtCnfgAgendaEntry 7 } -- General Port Configuration parameters prtGenCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtGenCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table allows the user to configure general port parameters." ::= {cnfgPrtGen 3} prtGenCnfgEntry OBJECT-TYPE SYNTAX PrtGenCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtGenCnfgIdx, prtGenCnfgSltIdx, prtGenCnfgPrtIdx } ::= { prtGenCnfgTable 1} PrtGenCnfgEntry ::= SEQUENCE { prtGenCnfgIdx Integer32, prtGenCnfgSltIdx INTEGER, prtGenCnfgPrtIdx Integer32, prtGenCnfgLinkToSlot INTEGER, prtGenCnfgLinkToPort Integer32, prtGenCnfgPortId Integer32, prtGenCnfgBusConnection INTEGER, prtGenCnfgInbandMng INTEGER, prtGenCnfgInbandMngRoutProt INTEGER, prtGenCnfgProtectionMode INTEGER, --not used prtGenCnfgConnect INTEGER, prtGenCnfgSignalingType INTEGER } prtGenCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= { prtGenCnfgEntry 1} prtGenCnfgSltIdx OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted." ::= { prtGenCnfgEntry 2} prtGenCnfgPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique external or internal port number. For MP: exPrt1 (1) .. exPrt16 (16) , notApplicable(100), inPrt1 (101) .. inPrt84 (184) " ::= { prtGenCnfgEntry 3} prtGenCnfgLinkToSlot OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the slot of the ML card to which the IO port is mapped." ::= { prtGenCnfgEntry 4} prtGenCnfgLinkToPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port in the prtGenCnfgLinkToSlot of the ML card to which the IO port is mapped. For MP: exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109), inPrt10 (110), inPrt11 (111), inPrt12 (112), inPrt13 (113), inPrt14 (114), inPrt15 (115), inPrt16 (116), inPrt17 (117), inPrt18 (118), inPrt19 (119), inPrt20 (120), inPrt21 (121), inPrt22 (122), inPrt23 (123), inPrt24 (124), inPrt25 (125), inPrt26 (126), inPrt27 (127), inPrt28 (128), inPrt29 (129), inPrt30 (130), inPrt31 (131), inPrt32 (132), inPrt33 (133), inPrt34 (134), inPrt35 (135), inPrt36 (136), inPrt37 (137), inPrt38 (138), inPrt39 (139), inPrt40 (140), inPrt41 (141), inPrt42 (142), inPrt43 (143), inPrt44 (144), inPrt45 (145), inPrt46 (146), inPrt47 (147), inPrt48 (148), inPrt49 (149), inPrt50 (150), inPrt51 (151), inPrt52 (152), inPrt53 (153), inPrt54 (154), inPrt55 (155), inPrt56 (156), inPrt57 (157), inPrt58 (158), inPrt59 (159), inPrt60 (160), inPrt61 (161), inPrt62 (162), inPrt63 (163), inPrt64 (164), inPrt65 (165), inPrt66 (166), inPrt67 (167), inPrt68 (168), inPrt69 (169), inPrt70 (170), inPrt71 (171), inPrt72 (172), inPrt73 (173), inPrt74 (174), inPrt75 (175), inPrt76 (176), inPrt77 (177), inPrt78 (178), inPrt79 (179), inPrt80 (180), inPrt81 (181), inPrt82 (182), inPrt83 (183), inPrt84 (184), notApplicable (255) " ::= { prtGenCnfgEntry 5} prtGenCnfgPortId OBJECT-TYPE SYNTAX Integer32 (0..16777215) MAX-ACCESS read-write STATUS current DESCRIPTION "IO Port Id for V5.1 use. This object is applicable only for part of the PSTN and ISDN IO ports. Generally, 0 is a valid value. Nevertheless, for ports that do not support this object, the value will be: notApplicable= 0" ::= { prtGenCnfgEntry 6} prtGenCnfgBusConnection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), partial (2), full (3), partialCD (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the support of the card regarding Bus Connection. Same value for all ports of the card. partial = 2 Buses (AB) full = 4 Buses (ABCD) partial CD = 2 Buses CD Actually the support depends on the card's HW. But, since CL has to assign data on Buses even when the card is not installed, this object has to be configured. If the actual card installed will not match the value configured, an Alarm will be issued." ::= { prtGenCnfgEntry 7} prtGenCnfgInbandMng OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether Inband Management is used over the link." ::= {prtGenCnfgEntry 8} prtGenCnfgInbandMngRoutProt OBJECT-TYPE SYNTAX INTEGER { none (1), rip2 (2), proprietaryRip (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Inband Mng Routing Protocol of the port." ::= {prtGenCnfgEntry 9} prtGenCnfgProtectionMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), secondary (2), primary (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Protection Mode of the port. notApplicable- when Bus Protection Point=No. For VC-4/Omni card this object is supported RO." ::= {prtGenCnfgEntry 10} prtGenCnfgConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the port should be considered in any of the mux algorithms." ::= {prtGenCnfgEntry 11} prtGenCnfgSignalingType OBJECT-TYPE SYNTAX INTEGER { legacy (3), abcd (4), none (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object selects the Type of Signaling used by the port." ::= {prtGenCnfgEntry 12} -- -- Compressed information. -- -- Specially for RadView management station -- prtCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprPrtGen 1 } prtCmprEntry OBJECT-TYPE SYNTAX PrtCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtCmprTypIdx, prtCmprCnfgIdx,prtCmprVersion,prtCmprSltIdx,prtCmprPrtIdx} ::= {prtCmprTable 1} PrtCmprEntry ::= SEQUENCE { prtCmprTypIdx Integer32, prtCmprCnfgIdx Integer32, prtCmprVersion Integer32, prtCmprSltIdx INTEGER, prtCmprPrtIdx Integer32, prtCmprObj OCTET STRING, prtCmprStatisticObj OCTET STRING } prtCmprTypIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Type of the Compressed being referred." ::= { prtCmprEntry 1} prtCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the configuration to which the Compressed information is related." ::= { prtCmprEntry 2} prtCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { prtCmprEntry 3} prtCmprSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number of the slot position where the card is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid." ::= { prtCmprEntry 4} prtCmprPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the port the compressed information relates to. Valid values: exPrt1 (1) .. exPrt16 (16) , inPrt1 (101) .. inPrt48 (148)." ::= { prtCmprEntry 5} prtCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { prtCmprEntry 6} prtCmprStatisticObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the compressed statistics information itself." ::= { prtCmprEntry 7} -- Compressed Dlci table in the Port level -- The only way of reading this table is by the command 'GET NEXT' prtDlciCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtDlciCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { cmprPrtGen 2 } prtDlciCmprEntry OBJECT-TYPE SYNTAX PrtDlciCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtDlciCmprCnfgIdx,prtDlciCmprVersion, prtDlciCmprSltIdx,prtDlciCmprPrtIdx,prtDlciCmprDlciIdx} ::= {prtDlciCmprTable 1} PrtDlciCmprEntry ::= SEQUENCE { prtDlciCmprCnfgIdx Integer32, prtDlciCmprVersion Integer32, prtDlciCmprSltIdx INTEGER, prtDlciCmprPrtIdx INTEGER, prtDlciCmprDlciIdx Integer32, prtDlciCmprObj OCTET STRING } prtDlciCmprCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the configuration to which the Compressed information is related." ::= { prtDlciCmprEntry 1} prtDlciCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { prtDlciCmprEntry 2} prtDlciCmprSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique number of the slot position where the module is inserted. In the ?004 Unit the entries psB(2),clB(4),io6(10)..io(16) are not valid." ::= { prtDlciCmprEntry 3} prtDlciCmprPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the port the compressed information relates to. All the values are valid." ::= { prtDlciCmprEntry 4} prtDlciCmprDlciIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the Dlci the compressed information relates to. The values are between 16 - 991." ::= { prtDlciCmprEntry 5} prtDlciCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { prtDlciCmprEntry 6} -- Compressed Alarm table in the Port level -- The only way of reading this table is by the command 'GET NEXT' prtAlarmsCmprTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {cmprPrtGen 3} prtAlarmsCmprEntry OBJECT-TYPE SYNTAX PrtAlarmsCmprEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtAlarmsCmprVersion,prtAlarmsCmprAlarmSlot, prtAlarmsCmprAlarmPort,prtAlarmsCmprAlarmIdx} ::= {prtAlarmsCmprTable 1} PrtAlarmsCmprEntry ::= SEQUENCE { prtAlarmsCmprVersion Integer32, prtAlarmsCmprAlarmSlot Integer32, prtAlarmsCmprAlarmPort Integer32, prtAlarmsCmprAlarmIdx Integer32, prtAlarmsCmprObj OCTET STRING } prtAlarmsCmprVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the version of the internal format of the Compressed data" ::= { prtAlarmsCmprEntry 1} prtAlarmsCmprAlarmSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the desired slot position. In the ?004 Unit the entries PsB(2),ClB(4),io6(10)..io(16) are not valid. For Stand-alone units, notApplicable(255) will appear." ::= { prtAlarmsCmprEntry 2} prtAlarmsCmprAlarmPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique identifier of the port the alarm applies to. All the values are valid. No alarms exist for a non-existing port. IP Bundles are considered a port too, for this matter." ::= { prtAlarmsCmprEntry 3} prtAlarmsCmprAlarmIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify an entry in the alarm status table of the agent." ::= { prtAlarmsCmprEntry 4} prtAlarmsCmprObj OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute is the compressed information itself." ::= { prtAlarmsCmprEntry 5} -- -- Specific port status for each module Type -- ***************************************** -- -- Megaplex?000/?004 port specific status for HS(TDM) modules -- HS-2,HS-3,HS-Q, HS-6, HS-12 prtSExHsfStatTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtSExHsfStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {statPrtMux 6} prtSExHsfStatEntry OBJECT-TYPE SYNTAX PrtSExHsfStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtSExHsfSltIdx, prtSExHsfPrtIdx } ::= {prtSExHsfStatTable 1} PrtSExHsfStatEntry ::= SEQUENCE { prtSExHsfSltIdx INTEGER, prtSExHsfPrtIdx INTEGER, prtSExHsfInterfaceTyp INTEGER, prtSExHsfRts INTEGER } prtSExHsfSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= { prtSExHsfStatEntry 1} prtSExHsfPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. " ::= { prtSExHsfStatEntry 2} prtSExHsfInterfaceTyp OBJECT-TYPE SYNTAX INTEGER { unknown (1), v35 (2), rs422 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique interface type of a selected port." ::= { prtSExHsfStatEntry 3} prtSExHsfRts OBJECT-TYPE SYNTAX INTEGER { unknown (1), notActive (2), active (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique RTS control signal state." ::= { prtSExHsfStatEntry 4} -- ISDN Port Status prtIsdnStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIsdnStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains ISDN Statistics parameters that do not appear in the standard MIBs or for agents that don't support the standard Index of Call Set Up Time." ::= { statPrtMux 16 } prtIsdnStatusEntry OBJECT-TYPE SYNTAX PrtIsdnStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entries for ISDN Statistics parameters that do not appear in the standard MIBs or for agents that don't support the standard Index of Call Set Up Time." INDEX { ifIndex } ::= { prtIsdnStatusTable 1 } PrtIsdnStatusEntry ::= SEQUENCE { prtIsdnStatusDspMode INTEGER, prtIsdnStatusCallState INTEGER, prtIsdnStatusCallingNumber DisplayString, prtIsdnStatusCalledNumber DisplayString, prtIsdnStatusCalledIP IpAddress, prtIsdnStatusCallDirection INTEGER } prtIsdnStatusDspMode OBJECT-TYPE SYNTAX INTEGER { voice (2), idle (3), fax (4), vbd (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The DSP can be in one of the following Modes: Voice, Idle, Fax, Voice Band Data (VBD)- Modem." ::= { prtIsdnStatusEntry 1 } prtIsdnStatusCallState OBJECT-TYPE SYNTAX INTEGER { present (2), overlapReceive (3), incoming (4), receive (5), initiated (6), overlapSend (7), outGoingProceed (8), callDeliver (9), active (10), disconnectIndicate (11), releaseRequest (12), disconnectReq (13), notActive (14) } MAX-ACCESS read-only STATUS current DESCRIPTION "The state that the current call is in." ::= { prtIsdnStatusEntry 2 } prtIsdnStatusCallingNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the local Number (ISDN Address) associated with this entry." ::= { prtIsdnStatusEntry 3 } prtIsdnStatusCalledNumber OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is the remote Number (ISDN Address) associated with this entry." ::= { prtIsdnStatusEntry 4 } prtIsdnStatusCalledIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This is the remote IP Address associated with this entry." ::= { prtIsdnStatusEntry 5 } prtIsdnStatusCallDirection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), incoming (2), outgoing (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Attribute indicating the Direction of the Call. The value of notApplicable will be used for example when prtIsdnStatusCallState = notActive(14)." ::= { prtIsdnStatusEntry 6 } cnfgMdlMux OBJECT IDENTIFIER ::= {mdlMux 1} mdlPbxFramerCnfg OBJECT IDENTIFIER ::= {cnfgMdlMux 1} mdlPbxFramerCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlPbxFramerCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains parameters relevant to a module belonging to a digital voice system, except mdlPbxFraEnhEcho which is relevant also for analog cards." ::= {mdlPbxFramerCnfg 1} mdlPbxFramerCnfgEntry OBJECT-TYPE SYNTAX MdlPbxFramerCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlPbxFraCnfgIdx, mdlPbxFraSltIdx } ::= {mdlPbxFramerCnfgTable 1} MdlPbxFramerCnfgEntry ::= SEQUENCE { mdlPbxFraCnfgIdx Integer32, mdlPbxFraSltIdx INTEGER, mdlPbxFraEnhEcho INTEGER, mdlPbxFraTSGroupAss INTEGER, mdlPbxFraSignalMode INTEGER, mdlPbxFraSignalVector OCTET STRING, mdlPbxFraSignalMask OCTET STRING, mdlPbxFraFramerSlot INTEGER, mdlPbxFraSignaling INTEGER, mdlPbxFraTransSigTs Integer32 } mdlPbxFraCnfgIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " -- DEFVAL {1} ::= { mdlPbxFramerCnfgEntry 1} mdlPbxFraSltIdx OBJECT-TYPE SYNTAX INTEGER{ io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16) } MAX-ACCESS read-only STATUS current DESCRIPTION "The slot relevant to this module." ::= { mdlPbxFramerCnfgEntry 2} mdlPbxFraEnhEcho OBJECT-TYPE SYNTAX INTEGER { notApplicable(1) , disabled(2), ms16(3), ms32(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Refers to external ports of an analogue module and to the internal ports of the other mvc4 types of modules. ms16(3) means that the four voice ports have enhanced echo of 16ms. ms32(4) means that the two first ports have enhanced echo of 32 ms while the last two ports have no enhanced echo." ::= { mdlPbxFramerCnfgEntry 3} mdlPbxFraTSGroupAss OBJECT-TYPE SYNTAX INTEGER{ group1(1), group2(2), group3(3), group4(4), group5(5), group6(6), group7(7), group8(8), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "In case of T1 modules: group1=(1,2,3,4), ...., group6=(21,22,23,24) while in case of E1 modules: - If prtExPh1MlLineType=g732sE1 or g732sE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,17), group5=(18,19,20,21),...,group7=(26,27,28,29) group8=(30,31). - If prtExPh1MlLineType=g732nE1 or g732nE1CRC: group1=(1,2,3,4),..,group4=(13,14,15,16), group5=(17,18,19,20),...,group7=(25,26,27,28) group8=(29,30,31)." ::= { mdlPbxFramerCnfgEntry 4} mdlPbxFraSignalMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), tieTrunk(2), tieInvert(3), casTrans(4), userDefined(5), ccsTrans(6), noSignaling(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Refers to the signaling mode of the Framer module. tieTrunk(2), tieInvert(3), casTrans(4) are standard coding of the signaling protocol. casTrans(4) is Channel Associated Signaling (the signaling is within the channels time slot). ccsTrans(6) is Transparent Common Channel Signaling (the signaling is not within the channels time slot - a TS for signaling is used). userDefined(5) allows the user to define the signaling protocol he wants. In this case, the next two MIB fields are relevant." DEFVAL { casTrans } ::= { mdlPbxFramerCnfgEntry 5} mdlPbxFraSignalVector OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "In the case of mdlPbxFraSignalMode = userDefined(5), this field defines the A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote In conjunction with the Mask, mdlPbxFraSignalMask, it is possible to compute the signal mode." DEFVAL { '0000'H} ::= { mdlPbxFramerCnfgEntry 6} mdlPbxFraSignalMask OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "In the case of mdlPbxFraSignalMode = userDefined(5), this field defines the 'don't care' A,B,C Bits. D bit is supplied for future versions. Bit 1 = Bit A ON Hook - Local Bit 2 = Bit B ON Hook - Local Bit 3 = Bit C ON Hook - Local Bit 4 = Bit D ON Hook - Local Bit 5 = Bit A OFF Hook - Local Bit 6 = Bit B OFF Hook - Local Bit 7 = Bit C OFF Hook - Local Bit 8 = Bit D OFF Hook - Local Bit 9 = Bit A ON Hook - Remote Bit 10 = Bit B ON Hook - Remote Bit 11 = Bit C ON Hook - Remote Bit 12 = Bit D ON Hook - Remote Bit 13 = Bit A OFF Hook - Remote Bit 14 = Bit B OFF Hook - Remote Bit 15 = Bit C OFF Hook - Remote Bit 16 = Bit D OFF Hook - Remote." DEFVAL { 'ffff'H } ::= { mdlPbxFramerCnfgEntry 7} mdlPbxFraFramerSlot OBJECT-TYPE SYNTAX INTEGER { io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16) } MAX-ACCESS read-write STATUS current DESCRIPTION "Slot where is sitting the Framer." ::= { mdlPbxFramerCnfgEntry 8} mdlPbxFraSignaling OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), endToEnd (2), localTermination(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Signaling - describes the way the signaling ABCD bits pass from the local extension to the remote extension and vice-versa. endToEnd = the signaling ABCD bits pass without change from local to remote extension. localTermination = the signaling ABCD bits received from the local extension are translated to different ON Hook/OFF Hook bit values and then passed to remote extension. This is relevant when the Local and Remote ON Hook/OFF Hook values are different." DEFVAL { endToEnd } ::= { mdlPbxFramerCnfgEntry 9} mdlPbxFraTransSigTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Time Slot that is used for Transparent CCS signaling. The values of this TS are 1-24 for T1 & 1-31 for E1. The default for E1 is 16 & for T1 it is 24. If no signaling is used then the TS should be 255 (None)." ::= { mdlPbxFramerCnfgEntry 10} --Protected IP Adresses list for ML-IP cards of MP-2100/4 and MP-2200 --for IP Ring Mode mdlProtIpTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlProtIpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains Protected IP Addresses for ML-IP cards when working in IP Ring Mode." ::= {cnfgMdlMux 2} mdlProtIpEntry OBJECT-TYPE SYNTAX MdlProtIpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlProtIpCnfgIdx, mdlProtIpSlotIdx, mdlProtIpAddress} ::= {mdlProtIpTable 1} MdlProtIpEntry ::= SEQUENCE { mdlProtIpCnfgIdx Integer32, mdlProtIpSlotIdx INTEGER, mdlProtIpAddress IpAddress, mdlProtIpRowStatus RowStatus } mdlProtIpCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg being accessed. Idx 255 relates to the TmpCnfg. For Agents having several configuration, Write operation is allowed only to the Temporary Configuration." ::= { mdlProtIpEntry 1} mdlProtIpSlotIdx OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the 2104 Unit the entries io6(10)..io16) are not valid." ::= { mdlProtIpEntry 2} mdlProtIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "A Protected IP address." ::= { mdlProtIpEntry 3 } mdlProtIpRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter allows creating/deleting entries of this table." ::= { mdlProtIpEntry 4 } statMdlMux OBJECT IDENTIFIER ::= {mdlMux 2} -- -- Card status table -- mdlStatTable OBJECT-TYPE SYNTAX SEQUENCE OF MdlStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= { statMdlMux 1 } mdlStatEntry OBJECT-TYPE SYNTAX MdlStatEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { mdlStatSltIdx } ::= { mdlStatTable 1} MdlStatEntry ::= SEQUENCE { mdlStatSltIdx INTEGER, mdlStatHostIP IpAddress, mdlStatHostMask IpAddress, mdlStatDefaultGateway IpAddress } mdlStatSltIdx OBJECT-TYPE SYNTAX INTEGER { psA (1), psB (2), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique number to identify a slot position in the mux. In the 2104 Unit the entries psB(2),clB(4),io6(10)..io12(16) are not valid." ::= { mdlStatEntry 1} mdlStatHostIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The host interface IP address when DHCP Client=Yes. This object is relevant only when DHCP Client=Yes " ::= { mdlStatEntry 2 } mdlStatHostMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The host interface subnet mask when DHCP Client=Yes. This object is relevant only when DHCP Client=Yes " ::= { mdlStatEntry 3 } mdlStatDefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "Default Gateway's IP Address when DHCP Client=Yes. This object is relevant only when DHCP Client=Yes " ::= { mdlStatEntry 4 } -- -- Specific port config for each module Type -- ***************************************** -- -- MPCL.1 configuration parameters -- --prtExClCnfgTable OBJECT IDENTIFIER ::= {prtClCnfg 1} -- prtInClInbandTable OBJECT IDENTIFIER ::= {prtClCnfg 2} prtExClCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExClCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table." ::= {prtClCnfg 1} prtExClCnfgEntry OBJECT-TYPE SYNTAX PrtExClCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "All the entries at this table are identical (have the same value) for all the configurations (1..100) except the TmpCnfg. The write operation into the Table Objects is valid only to the TmpCnfg entry." INDEX {prtExClCnfgIdx, prtExClSltIdx, prtExClPrtIdx } ::= { prtExClCnfgTable 1} PrtExClCnfgEntry ::= SEQUENCE { prtExClCnfgIdx Integer32, prtExClSltIdx INTEGER, prtExClPrtIdx INTEGER, prtExClUsage INTEGER, prtExClRate INTEGER, prtExClDataBits INTEGER, prtExClParity INTEGER, prtExClStopBits INTEGER, prtExClRoutingProtocol INTEGER, prtExClEnabled INTEGER } prtExClCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg." ::= { prtExClCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExClSltIdx OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. Because the second Cl is only for redundancy, all the parameters are identical in the two modules, i.e. change of any parameter in one module will change automatically the value of the other module.. In the ?004 Unit the entry clB(4) is not valid." ::= { prtExClCnfgEntry 2} prtExClPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. " ::= { prtExClCnfgEntry 3} prtExClUsage OBJECT-TYPE SYNTAX INTEGER { unknown (1), noUse (2), nmsSlip (3), nmsPpp (4), muxSlip (5), muxPpp (6), terminal(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates what is the usage of the port." ::= { prtExClCnfgEntry 4} prtExClRate OBJECT-TYPE SYNTAX INTEGER { r300Bps (1), r1200Bps (2), r2400Bps (3), r4800Bps (4), r9600Bps (5), r19200Bps (6), r38400Bps (7), r57600Bps (8), r115200Bps (9) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the operation rate of the port." ::= { prtExClCnfgEntry 5} prtExClDataBits OBJECT-TYPE SYNTAX INTEGER { dataBits7Bits (1), dataBits8Bits (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the number of data bits in async frame" ::= { prtExClCnfgEntry 6} prtExClParity OBJECT-TYPE SYNTAX INTEGER { odd (1), even (2), none (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates if the parity operation mode in async frame" ::= { prtExClCnfgEntry 7} prtExClStopBits OBJECT-TYPE SYNTAX INTEGER { stopBits1Bit (1), stopBits1dot5Bits (2), stopBits2Bits (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the minimum number of stop bits in the tx async frame" ::= { prtExClCnfgEntry 8} prtExClRoutingProtocol OBJECT-TYPE SYNTAX INTEGER { none (1), rip2 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the routing protocol of the port. When prtExClUsage is nmsSlip or nmsPpp - all values are applicable . Else - only 'none' is applicable." ::= { prtExClCnfgEntry 9} prtExClEnabled OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), disabled (2), enabled (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates if Ethernet port of CL is enabled or not for management. It is applicable only on the ETH port of the CL, when the MP includes an ML-IP card. disabled - will happen when there is Inband Management via the ML-IP link/s enabled - will happen when ML-IP link/s is not used for Inband Management, but CL's ETH port ." ::= { prtExClCnfgEntry 10} -- -- MPH1.T1, MPH1.E1, MTML.1/T1 , MTML.1/E1, ML-20 -- TDM and Hybrid(TDM & Packet) Main Link Modules -- --prtExPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 1} --prtExPh1MlTsTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 2} --prtInPh1MlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 3} --prtInPh1MlDlciTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 4} --prtPhMlCnfgTable OBJECT IDENTIFIER ::= {prtPh1MlCnfg 5} -- -- T1/E1 Port Objects -- prtExPh1MlCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPh1MlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "- For products supporting more than one configuration, the write operation into the Table is valid only to the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table will be to prtExPh1MlCnfgIdx=1." ::= {prtPh1MlCnfg 1} prtExPh1MlCnfgEntry OBJECT-TYPE SYNTAX PrtExPh1MlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPh1MlCnfgIdx, prtExPh1MlSltIdx, prtExPh1MlPrtIdx } ::= { prtExPh1MlCnfgTable 1} PrtExPh1MlCnfgEntry ::= SEQUENCE { prtExPh1MlCnfgIdx Integer32, prtExPh1MlSltIdx INTEGER, prtExPh1MlPrtIdx INTEGER, prtExPh1MlConnect INTEGER, prtExPh1MlLineType INTEGER, prtExPh1MlLineCode INTEGER, prtExPh1MlLineLen INTEGER, prtExPh1MlRestoreTime INTEGER, prtExPh1MlTxGain INTEGER, prtExPh1MlRxSensitivity INTEGER, prtExPh1MlIdleCode Integer32, prtExPh1MlTdmTrunk INTEGER, prtExPh1MlClkMode INTEGER, prtExPh1MlMfClkSrcSlt INTEGER, prtExPh1MlMfClkSrcPrt INTEGER, prtExPh1MlFdlType INTEGER, prtExPh1MlInbandMng INTEGER, prtExPh1MlInbandMngRate INTEGER, prtExPh1MlRedundType INTEGER, prtExPh1MlRedundSlot INTEGER, prtExPh1MlRedundPort INTEGER, prtExPh1MlRedundRecTime Integer32, prtExPh1MlInbandMngRoutProt INTEGER, prtExPh1MlIfType INTEGER, prtExPh1MlMultiplier INTEGER, prtExPh1MlSupportedTS Integer32, prtExPh1MlImpedance INTEGER, prtExPh1MlQ50BwControl INTEGER, prtExPh1MlQ50SignalPair INTEGER, prtExPh1MlInternalSwitch INTEGER, prtExPh1MlSigService INTEGER, prtExPh1MlFragmentSize Integer32 } prtExPh1MlCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPh1MlCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPh1MlSltIdx OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid. For the Vmux2100 Main Board notApplicable (1) is used." ::= { prtExPh1MlCnfgEntry 2} prtExPh1MlPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), exPrt5 (5), exPrt6 (6), exPrt7 (7), exPrt8 (8), exPrt9 (9), exPrt10 (10), exPrt11 (11), exPrt12 (12), exPrt13 (13), exPrt14 (14), exPrt15 (15), exPrt16 (16), exPrt17 (17), exPrt18 (18), inPrt1 (101), inPrt2 (102), inPrt3 (103), inPrt4 (104), inPrt5 (105), inPrt6 (106), inPrt7 (107), inPrt8 (108), inPrt9 (109), inPrt10 (110), inPrt11 (111), inPrt12 (112), inPrt13 (113), inPrt14 (114), inPrt15 (115), inPrt16 (116), inPrt17 (117), inPrt18 (118), inPrt19 (119), inPrt20 (120), inPrt21 (121), inPrt22 (122), inPrt23 (123), inPrt24 (124), inPrt25 (125), inPrt26 (126), inPrt27 (127), inPrt28 (128), inPrt29 (129), inPrt30 (130), inPrt31 (131), inPrt32 (132), inPrt33 (133), inPrt34 (134), inPrt35 (135), inPrt36 (136), inPrt37 (137), inPrt38 (138), inPrt39 (139), inPrt40 (140), inPrt41 (141), inPrt42 (142), inPrt43 (143), inPrt44 (144), inPrt45 (145), inPrt46 (146), inPrt47 (147), inPrt48 (148), inPrt49 (149), inPrt50 (150), inPrt51 (151), inPrt52 (152), inPrt53 (153), inPrt54 (154), inPrt55 (155), inPrt56 (156), inPrt57 (157), inPrt58 (158), inPrt59 (159), inPrt60 (160), inPrt61 (161), inPrt62 (162), inPrt63 (163), inPrt64 (164), inPrt65 (165), inPrt66 (166), inPrt67 (167), inPrt68 (168), inPrt69 (169), inPrt70 (170), inPrt71 (171), inPrt72 (172), inPrt73 (173), inPrt74 (174), inPrt75 (175), inPrt76 (176), inPrt77 (177), inPrt78 (178), inPrt79 (179), inPrt80 (180), inPrt81 (181), inPrt82 (182), inPrt83 (183), inPrt84 (184) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. MP-2100/2200: MTML-1/E1 and MTML-1/T1 cards have only one external interface. inPrt1, inPrt2 - for MTML-H/2E1 and HSH cards. inPrt1..inPrt4 - for MTML-E2 and MSL-4 cards. exPrt2..exPrt4 - for MTML-4 cards and others exPrt1..exPrt8 - for ML-8 cards. inPrt1..inPrt8 - for MSL-8 and VF-30 card family. MP-104/204: only exPrt3 (3) is applicable. MP-4100: intPrt1...intPrt84 - for CLX cards. For other products' index see their specification." ::= { prtExPh1MlCnfgEntry 3} prtExPh1MlConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the card considerations because it may indicate that the module has only one physical interface." ::= {prtExPh1MlCnfgEntry 4} prtExPh1MlLineType OBJECT-TYPE SYNTAX INTEGER { esfT1 (2), --> dsx1ESF sfT1 (3), --> dsx1D4 g732nE1 (4), --> dsx1E1 g732nE1CRC (5), --> dsx1E1-CRC g732sE1 (6), --> dsx1E1-MF g732sE1CRC (7), --> dsx1E1-MF-CRC g732unframed (8), --> dsx1Unframed, for T1 Unframed e1Unframed (9), --> dsx1E1Unframed framed (101) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line type parameter for T1/E1 interface. The user should select only the values which are relevant to the specific port: (2),(3), (8) - for T1 port (4)..(7), (9) - for E1 port. (101) framed - This value does not exist in standard MIB and is used for a non-standard E1 port that doesn't has real framer. Note: for old devices, g732unframed(8) was used as E1 Unframed. That was because at the time this value did not exist in the standard MIB (RFC-1406), so we added it in private MIB. Now that it was added to standard MIB, private MIB was updated as well. This parameter has the same values as dsx1LineType in DS1 MIB (RFC-3895). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7) g732unframed dsx1Unframed (8) --from RFC-3895 e1Unframed dsx1E1Unframed (9) --from RFC-3895 " ::= { prtExPh1MlCnfgEntry 5} prtExPh1MlLineCode OBJECT-TYPE SYNTAX INTEGER { b7T1 (1), --> dsx1JBZS (for E1 & T1) b8zsT1 (2), --> dsx1B8ZS (for E1 & T1) transT1(3), --> dsx1AMI hdb3E1 (4), --> dsx1HDB3 (for E1 & T1) notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for MPH.1/T1 E1 line code parameters for MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)" ::= { prtExPh1MlCnfgEntry 6} prtExPh1MlLineLen OBJECT-TYPE SYNTAX INTEGER { unknown (1), len0p133ft (2), len134p266ft (3), len267p399ft (4), len400p533ft (5), len534p655ft (6), lenFcc68 (7), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line length parameter used only for T1/DSU interfaces. lenXXXpXXXft = len-XXX-XXXft." ::= { prtExPh1MlCnfgEntry 7} prtExPh1MlRestoreTime OBJECT-TYPE SYNTAX INTEGER { restoreT1secFast (2), restoreT10sec62411 (3), ccittE1 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface." ::= { prtExPh1MlCnfgEntry 8} prtExPh1MlTxGain OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), txGain0db (2), txGain7dot5db (3), txGain15db (4), txGain22dot5db (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the tx gain parameter used only for T1/CSU interfaces." ::= { prtExPh1MlCnfgEntry 9} prtExPh1MlRxSensitivity OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), low26dBm (2), high36dBm (3), shortHaul (4), longHaul (5), low15dbm (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the rx line sensitivity parameter. low26dBm, high36dBm - applicable for T1-CSU shortHaul, longHaul - applicable for MTML-4 cards low15dbm was added for vmux110/210 T1 ports." ::= { prtExPh1MlCnfgEntry 10} prtExPh1MlIdleCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the code for transmission in empty time slots. Type value(00-FFH), Excluding 0H,8H,10H,12H,21H,24H,42H,49H, 84H,92H" ::= { prtExPh1MlCnfgEntry 11} prtExPh1MlTdmTrunk OBJECT-TYPE SYNTAX INTEGER { linkA (1), linkB (2), none (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port is used to transfer TDM cards data and through which Bus." ::= {prtExPh1MlCnfgEntry 12} prtExPh1MlClkMode OBJECT-TYPE SYNTAX INTEGER { internalLocal (1), loopBackLocal (2), nodalTiming (3), loopBackFromLink (4), loopBackFromChannel (5), loopbackFromSystem (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the clock operation mode of the T1/E1 interface. Ports that are connected to the TDM Buses must be in nodalTiming(3) clock mode. " ::= {prtExPh1MlCnfgEntry 13} prtExPh1MlMfClkSrcSlt OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), local (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port Tx multiframe is synchronized with Rx multiframe of another port and the slot position of that port. This operation is required in order to bypass signaling of PCM voice channels. Its value is always local(2) when the port isn't connected to any TDM bus. When it's value is local(2) there is no meaning to 'prtExPh1MlMfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= {prtExPh1MlCnfgEntry 14} prtExPh1MlMfClkSrcPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), inPrt1 (101), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify a port position in the mux. It has no effect when the prtExPh1MlMfClkSrcSlt selected is Local. inPrt1 - for MTML-H/E1 cards." ::= {prtExPh1MlCnfgEntry 15} prtExPh1MlFdlType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), response (2), command (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify the side of the FDL operation. Normal: 'response' for the user side and 'command' for the PTT side. Applicable only when working with ESF-T1 link" ::= {prtExPh1MlCnfgEntry 16} prtExPh1MlInbandMng OBJECT-TYPE SYNTAX INTEGER { off (2), fdlOrTs0 (3), dedicatedTs (4), dedicatedPpp (5), dedicatedFr (6), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify an Inband management over the link." ::= {prtExPh1MlCnfgEntry 17} prtExPh1MlInbandMngRate OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), r4k (2), r8k (3), r12k (4), r16k (5), r32k (6), r64k (7), r20k (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify the rate of the Inband management (Kbps). E1 port - it is not applicable when prtExPh1MlInbandMng selected is off. T1 port - it is not applicable when prtExPh1MlInbandMng selected is off OR fdlOrTs0." ::= {prtExPh1MlCnfgEntry 18} prtExPh1MlRedundType OBJECT-TYPE SYNTAX INTEGER { none (1), dualCableAIS (2), yCable (3), dualCableParallelTx (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines the ML redundancy type: none - no ML redundacy dualCableAIS - each ML card is connected by a separate dualCableParallelTx cable to the other MUX (two cables connect two MUXes). There are two types of dual redundancy. yCable - Y cable is connected to both ML cards (one cable connects two MUXes). Default=none When only one ML card exists, the type can be only 'none'. The value should be the same for both ML slots." ::= {prtExPh1MlCnfgEntry 19} prtExPh1MlRedundSlot OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the slot containing the redundacy ML card, coupled with the current ML (prtExPh1MlSltIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. In the ?004 Unit the entries io6(10)..io12(16) are not valid When value is not 'none', it should be mutual to the redundant ML slot." ::= {prtExPh1MlCnfgEntry 20} prtExPh1MlRedundPort OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), inPrt1 (101), inPrt2 (102), inPrt3 (103), inPrt4 (104), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the redundacy ML port, coupled with the current ML port (prtExPh1MlPrtIdx). When prtExPh1MlRedundType=none (no ML redundancy) this object will be 'notApplicable'. When value is not 'none', it should be mutual to the redundant ML port. inPrt1 - for MTML-H/E1 cards. inPrt1..inPrt4 - for MTML-E2 cards. exPrt2..exPrt4 - for MTML-4 cards." ::= {prtExPh1MlCnfgEntry 21} prtExPh1MlRedundRecTime OBJECT-TYPE SYNTAX Integer32 (1..99) MAX-ACCESS read-write STATUS current DESCRIPTION "Redundancy Recovery Time (sec). After switching the ML card to the current (prtExPh1MlSltIdx), the next ML switch can be performed only after a minimum time, indicated by this object." ::= {prtExPh1MlCnfgEntry 22} prtExPh1MlInbandMngRoutProt OBJECT-TYPE SYNTAX INTEGER { none (1), rip2 (2), proprietary (3), proprietaryNoNmsTx (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Inband Mng routing protocol of the port." ::= {prtExPh1MlCnfgEntry 23} prtExPh1MlIfType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), csu (2), dsu (3), ltu (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Interface type of the port. For T1 - csu, dsu are the valid values For E1 - dsu, ltu are the valid values." ::= {prtExPh1MlCnfgEntry 24} prtExPh1MlMultiplier OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), br56 (2), br64 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The data rate of each TS. The multiplier values can be 56 kbps or 64 kbps." ::= {prtExPh1MlCnfgEntry 25} prtExPh1MlSupportedTS OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Supported Time Slots by the agent. For Vmux-110 there is HW that supports less than 31/24 Time Slots for the E1/T1 port." ::= {prtExPh1MlCnfgEntry 26} prtExPh1MlImpedance OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), unbalanced (2), balanced (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Line Impedance. For T1 (always balanced), impedance is 100 ohm. For E1: - balanced = 120 ohm - unbalanced = 75 ohm." ::= {prtExPh1MlCnfgEntry 27} prtExPh1MlQ50BwControl OBJECT-TYPE SYNTAX INTEGER { disable (2), annexA (3), annexB (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables configuration of Q.50 Bandwidth Control on the port. If the bandwidth exceeds a certain threshold it is possible to disable new calls in the PBX via Q.50 protocol. Q.50 supports only E1 ports with Line Types: E1-MF (G.732S), E1-CRC-MF(G.732SCRC ) It does not support T1 ports. Annex A - the basic type of Q.50 which focuses only on the bandwidth control. Can use one of the following pairs of signaling bits: A&B or C&D. Annex B - Expansion of Annex A which includes also call release messages and Maintenance Messages. Uses A&B bits only." ::= {prtExPh1MlCnfgEntry 28} prtExPh1MlQ50SignalPair OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), aAndB (2), cAndD (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Q.50 Signaling bits Pair that is currently in use: A&B bits or C&D bits. For Annex B it will always be: aAndB (2)." ::= {prtExPh1MlCnfgEntry 29} prtExPh1MlInternalSwitch OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter shows whether the data will be transferred from one port to the other port within the same group of 2 ports. The default value is: Enable. Disable value might be necessary for security implementations or for ring applications. For Vmux-2100 device this parameter is used on the Channelized Cards. Both ports in each group should have the same value for this parameter." ::= {prtExPh1MlCnfgEntry 30} prtExPh1MlSigService OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), normal (2), advanced (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Signaling Service given by this link. notApplicable - for T1 links normal - usual Signaling advanced - V5 Signaling. " ::= {prtExPh1MlCnfgEntry 31} prtExPh1MlFragmentSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the maximum number of bytes permitted in a packet send over the Link. Exceeding this size will cause packet fragmentation." ::= {prtExPh1MlCnfgEntry 32} -- -- MPH1.T1 & MPH1.E1 -- Time Slot Assignment Table -- prtExPh1MlTsTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPh1MlTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry, except prtExPh1MlTsTest that will be written directly to the Active Configuration." ::= {prtPh1MlCnfg 2} prtExPh1MlTsEntry OBJECT-TYPE SYNTAX PrtExPh1MlTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPh1MlTsCnfgIdx, prtExPh1MlTsSltIdx, prtExPh1MlTsPrtIdx, prtExPh1MlTsIdx } ::= { prtExPh1MlTsTable 1} PrtExPh1MlTsEntry ::= SEQUENCE { prtExPh1MlTsCnfgIdx Integer32, prtExPh1MlTsSltIdx INTEGER, prtExPh1MlTsPrtIdx INTEGER, prtExPh1MlTsIdx Integer32, prtExPh1MlTsIConSlot INTEGER, prtExPh1MlTsIConPrt Integer32, prtExPh1MlTsIConTs Integer32, prtExPh1MlTsExt OBJECT IDENTIFIER, prtExPh1MlTsTest INTEGER, prtExPh1MlTsType INTEGER, prtExPh1MlTsBundle Integer32, prtExPh1MlTsTestDuration Integer32, prtExPh1MlTsSubChType INTEGER, prtExPh1MlTsSubChMask Integer32, prtExPh1MlTsChRate INTEGER, prtExPh1MlTsByteReversal INTEGER, prtExPh1MlTsSigProfile INTEGER } prtExPh1MlTsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPh1MlTsEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPh1MlTsSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid. For the Vmux2100 Main Board notApplicable (255) is used." ::= { prtExPh1MlTsEntry 2} prtExPh1MlTsPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), exPrt5 (5), exPrt6 (6), exPrt7 (7), exPrt8 (8), exPrt9 (9), exPrt10 (10), exPrt11 (11), exPrt12 (12), exPrt13 (13), exPrt14 (14), exPrt15 (15), exPrt16 (16), exPrt17 (17), exPrt18 (18), inPrt1 (101), inPrt2 (102), inPrt3 (103), inPrt4 (104), inPrt5 (105), inPrt6 (106), inPrt7 (107), inPrt8 (108), inPrt9 (109), inPrt10 (110), inPrt11 (111), inPrt12 (112), inPrt13 (113), inPrt14 (114), inPrt15 (115), inPrt16 (116), inPrt17 (117), inPrt18 (118), inPrt19 (119), inPrt20 (120) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have only one external interface. exPrt2 - for ME1-2, MT1-2 and mhsPri cards. exPrt3, exPrt4 - for mhsPri cards. inPrt1 - for MTML-H/E1 cards." ::= { prtExPh1MlTsEntry 3} prtExPh1MlTsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling." ::= { prtExPh1MlTsEntry 4} prtExPh1MlTsIConSlot OBJECT-TYPE SYNTAX INTEGER { unknown (1), noConnect (2), split (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS)." ::= {prtExPh1MlTsEntry 5} prtExPh1MlTsIConPrt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the internally (In Mux) connected/routed port. For MP, the values will be: { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } For other products see specific values at spec." ::= {prtExPh1MlTsEntry 6} prtExPh1MlTsIConTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated to multiframe synchronization and voice signaling." ::= {prtExPh1MlTsEntry 7} prtExPh1MlTsExt OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "A pointer to an extension of this table: prtExTsSplitTable. - If prtExPh1MlTsIConSlot='split', its value should be set to the OBJECT IDENTIFIER of the prtExTsSplitTable, with its relevant CnfgIdx, SltIdx, PrtIdx, TsIdx and 1st TsBit. - If prtExPh1MlTsIConSlot is not 'split', its value should be set to the OBJECT IDENTIFIER { 0 0 }. " ::= { prtExPh1MlTsEntry 8 } prtExPh1MlTsTest OBJECT-TYPE SYNTAX INTEGER { none (1), localLoop (2), remoteLoop (3), remoteBert (8), -- BERT localToneInjection (9), remoteToneInjection (18), localBert (30), split (254), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a test to be activated on the selected TS. It is applicable only when prtSTstCmd=testPerTS(31). notApplicable - when prtSTstCmd is NOT testPerTS(31). none - no test is applied for the selected TS. split - when the tests are per Bit of the selected TS." ::= { prtExPh1MlTsEntry 9 } prtExPh1MlTsType OBJECT-TYPE SYNTAX INTEGER { noConnect (2), data (3), voice (4), cas (5), ss7 (6), transparent (7), data2 (8), data3 (9), data4 (10), ss7n2 (11), hdlcV2Compatible (12), subCh1 (13), subCh2 (14), subCh3 (15), subCh4 (16), subCh5 (17), subCh6 (18), subCh7 (19), subCh8 (20), trau (21), qmux (22), dynamic (23), signaling (24), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Time Slot Type. Transparent - means that the Time Slot will be Rx/Tx as is without processing it. If the device requires more than 1 unique data or ss7 Time Slot, options with numbers can be used like: data...data4. Each numbered Type can go to a different destination. ss7n2 - means the 2nd group of ss7 Time Slots. data2,data3, data4 mean group 2,3,4 of Data Time Slots. subCh1...subCh8 mean Sub Channel 1...8, respectively. trau, qmux, dynamic, signaling - are used by GSM devices." ::= { prtExPh1MlTsEntry 10 } prtExPh1MlTsBundle OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of the bundle containing this Time Slot. If no bundle exists for this TS or the bundle number is irrelevant, the value will be 0." ::= { prtExPh1MlTsEntry 11 } prtExPh1MlTsTestDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the maximum duration of executing a test on the specific TS. This entry applies to all the test operations. For the Vmux2100 the values are: 0 - 60 seconds. A zero value specifies no time limitation. When the test isn't active, the agent initiates this object to 2 when the duration is needed and to 0 if its not required. The user should set this parameter after setting the 'prtExPh1MlTsTest' parameter." ::= { prtExPh1MlTsEntry 12 } prtExPh1MlTsSubChType OBJECT-TYPE SYNTAX INTEGER { hdlc (1), transparent (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Time Slot Sub-Channel Type. This variable is relevant only when Time-Slot Type is SubCh (e.g. prtExPh1MlTsType = subCh1...subCh8)." ::= { prtExPh1MlTsEntry 13 } prtExPh1MlTsSubChMask OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Sub-Channel Type Mask. This variable is relevant only when Time-Slot Type is SubCh (e.g. prtExPh1MlTsType = subCh1...subCh8)." ::= { prtExPh1MlTsEntry 14 } prtExPh1MlTsChRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r16Kbps (2), r32Kbps (3), r64Kbps (4), r8Kbps (5), auto (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Rate of the Signaling Channel. notApplicable(1) when TS Type is other than Signaling or Transparent" ::= { prtExPh1MlTsEntry 15 } prtExPh1MlTsByteReversal OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Byte Reversal. This variable defines whether the LSB or MSB is transmitted first. no(2) - MSB is transmitted first yes(3) - LSB is transmitted first." ::= { prtExPh1MlTsEntry 16 } prtExPh1MlTsSigProfile OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), -- none (2), p1 (3), p2 (4), p3 (5), p4 (6), p5 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Signaling Profile of the port. It is applicable only when prtMl4SigProfile=perTS. p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4 p5 = profile 5 " ::= { prtExPh1MlTsEntry 17 } -- -- MPH.1/T1 & MPH.1/E1 -- Internal port objects table -- (only for the Hybrid modules) -- prtInPh1MlCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInPh1MlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtPh1MlCnfg 3} prtInPh1MlCnfgEntry OBJECT-TYPE SYNTAX PrtInPh1MlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInPh1MlCnfgIdx, prtInPh1MlSltType, prtInPh1MlPrtIdx } ::= { prtInPh1MlCnfgTable 1} PrtInPh1MlCnfgEntry ::= SEQUENCE { prtInPh1MlCnfgIdx Integer32, prtInPh1MlSltType INTEGER, prtInPh1MlPrtIdx Integer32, prtInPh1MlConnect INTEGER, prtInPh1MlRate INTEGER, prtInPh1MlProtocol INTEGER, prtInPh1MlConnectionTyp INTEGER, prtInPh1MlCongResponse INTEGER, prtInPh1MlCongLevel Integer32, prtInPh1MlTc INTEGER, prtInPh1MlFlowControl INTEGER, prtInPh1MlSegment INTEGER, prtInPh1MlFrMngProt INTEGER, prtInPh1MlEnqPeriod Integer32, prtInPh1MlFullRptPeriod Integer32, prtInPh1MlFrWindowSize Integer32, prtInPh1MlErrorsThreshold Integer32, prtInPh1MlMaxIdleTime Integer32, prtInPh1MlBearerCh INTEGER, prtInPh1MlAssociatedExCh INTEGER, prtInPh1MlClockEncoding INTEGER, prtInPh1MlMinSeparators Integer32, prtInPh1MlCcittCrc INTEGER, prtInPh1MlFrameSeparator INTEGER } prtInPh1MlCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtInPh1MlCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtInPh1MlSltType OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. For ISDN BRI port of MX300/30: io1(5) = isdn1(5) and io2(6) = isdn2(6) In the ?004 Unit the entries io6(10)..io12(16) are not valid" ::= { prtInPh1MlCnfgEntry 2} prtInPh1MlPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. MPH.1/E1 and MPH.1/T1 cards have three internal interfaces. MX3000 modules may have up to 50 internal ports." ::= { prtInPh1MlCnfgEntry 3} prtInPh1MlConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= { prtInPh1MlCnfgEntry 4} prtInPh1MlRate OBJECT-TYPE SYNTAX INTEGER { r1x56eq56Kbps (1), r1x64eq64Kbps (2), r2x56eq112Kbps (3), r2x64eq128Kbps (4), r3x56eq168Kbps (5), r3x64eq192Kbps (6), r4x56eq224Kbps (7), r4x64eq256Kbps (8), r5x56eq280Kbps (9), r5x64eq320Kbps (10), r6x56eq336Kbps (11), r6x64eq384Kbps (12), r7x56eq392Kbps (13), r7x64eq448Kbps (14), r8x56eq448Kbps (15), r8x64eq512Kbps (16), r9x56eq504Kbps (17), r9x64eq576Kbps (18), r10x56eq560Kbps (19), r10x64eq640Kbps (20), r11x56eq616Kbps (21), r11x64eq704Kbps (22), r12x56eq672Kbps (23), r12x64eq768Kbps (24), r13x56eq728Kbps (25), r13x64eq832Kbps (26), r14x56eq784Kbps (27), r14x64eq896Kbps (28), r15x56eq840Kbps (29), r15x64eq960Kbps (30), r16x56eq896Kbps (31), r16x64eq1024Kbps(32), r17x56eq952Kbps (33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), r32x56eq1792Kbps(63), r32x64eq2048Kbps(64), r1x1dot5eq1dot5M(65), r2x1dot5eq3M (66), r3x1dot5eq4dot5M(67), r4x1dot5eq6M (68), r5x1dot5eq7dot5M(69), r6x1dot5eq9M (70), r7x1dot5eq10dot5M(71), r8x1dot5eq12M (72), r1x2Meq2M (73), r2x2Meq4M (74), r3x2Meq6M (75), r4x2Meq8M (76), r5x2Meq10M (77), r6x2Meq12M (78), r7x2Meq14M (79), r8x2Meq16M (80), noRate (100) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed. " ::= { prtInPh1MlCnfgEntry 5} prtInPh1MlProtocol OBJECT-TYPE SYNTAX INTEGER { fr (1), frPlus (2), pCellRelay (3), hdlcSdlc (4), transparentHdlc (5), ciscoBridgedEth (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the applied protocol." ::= { prtInPh1MlCnfgEntry 6} prtInPh1MlConnectionTyp OBJECT-TYPE SYNTAX INTEGER { sameNetManaged (1), sameNetNotMana (2), user (3), otherNet (4), pubNet (5), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management operation (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetNotMana - indicates network internal line, but the remote mux is not managed by the nms. User - User to Network Interface. OtherNet - Network To Network Interfce. PubNet - Access Mux To PubNet Interface." ::= { prtInPh1MlCnfgEntry 7} prtInPh1MlCongResponse OBJECT-TYPE SYNTAX INTEGER { no (2), flowControl (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/receive becn to/from the network). no - do nothing FlowControl - translate the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done in both directions." ::= { prtInPh1MlCnfgEntry 8} prtInPh1MlCongLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the level of delayed data in precents of the total available dynamic memory, for which the port will start to operate . The resolution of the parameter is 5 percent. Valid values: 10..70, 255. 255=notApplicable." ::= { prtInPh1MlCnfgEntry 9} prtInPh1MlTc OBJECT-TYPE SYNTAX INTEGER { tc1sec (1), tc2sec (2), tc3sec (3), tc4sec (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports in the specific card. 255=notApplicable." ::= { prtInPh1MlCnfgEntry 10} prtInPh1MlFlowControl OBJECT-TYPE SYNTAX INTEGER { none (2), fecnBecn (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the required flow control betweeen the port and the remote equipment." ::= { prtInPh1MlCnfgEntry 11} prtInPh1MlSegment OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), s36Byte (2), s150Byte (3), s264Byte (4), s378Byte (5), s492Byte (6), s236Byte (7), s472Byte (8), s708Byte (9), s944Byte (10), s1180Byte (11) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Segmentation in Bytes. In protocol FR+, ISDN internals, MX 30/300 the segmentation is: 50 (2) ,158 (3) ,266 (4) ,376 (5), 484 (6) In MX 3000/4: For protocol FR+ (internal ISDN ports of MHS.S, MHS.U, MHS.E1, MHS.T1 cards) segmentation values are: 236 (7),472 (8), 708 (9), 944 (10) ,1180 (11)" ::= { prtInPh1MlCnfgEntry 12} prtInPh1MlFrMngProt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), lmi (3), ansiT1 (4), --Annex D annexA (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtInPh1MlConnectionTyp = sameNetManaged, this object will be RO (internally determined). " ::= { prtInPh1MlCnfgEntry 13} prtInPh1MlEnqPeriod OBJECT-TYPE SYNTAX Integer32 (0..30) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable." ::= { prtInPh1MlCnfgEntry 14} prtInPh1MlFullRptPeriod OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite (never sent). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable." ::= { prtInPh1MlCnfgEntry 15} prtInPh1MlFrWindowSize OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable." ::= { prtInPh1MlCnfgEntry 16} prtInPh1MlErrorsThreshold OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtInPh1MlFrMngProt is NOT (notApplicable or none). 0=notApplicable. " ::= { prtInPh1MlCnfgEntry 17} prtInPh1MlMaxIdleTime OBJECT-TYPE SYNTAX Integer32 (0..1800) MAX-ACCESS read-write STATUS current DESCRIPTION "Move to higher prioritized connected link after this period of seconds of silence on the current link. 0=Never. Never move to higher prioritized connected link. UNIT is seconds. Valid values are: 0, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 60, 120, 180, 240, 300, 360, 420, 480, 540, 600, 900, 1200, 1500, 1800. Attempt to Set an invalid value will result in getting the default value." DEFVAL { 10 } ::= {prtInPh1MlCnfgEntry 18} prtInPh1MlBearerCh OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), channelB1 (3), channelB2 (4), chB1andchB2 (5), none (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines which B (bearer) channels are used for transferring ISDN data. Default value is: none (255). anyChannel (2) is skipped because it is not in use here." ::= {prtInPh1MlCnfgEntry 19} prtInPh1MlAssociatedExCh OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the external port associated to this internal port. At present, it is used by the Hybrid (mp2100h), MHS-4 cards which can have up to 64 dynamic internal ports associated with External ports. For ISDN cards, the value will be: notApplicable (255). The associated external of an ISDN internal port is represented by the MIB object: prtIsdnDirectoryPrtNu." ::= { prtInPh1MlCnfgEntry 20} prtInPh1MlClockEncoding OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), nrz (2), nrzI (3), fm0 (4), manchester (5), diffManchester(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols." ::= { prtInPh1MlCnfgEntry 21} prtInPh1MlMinSeparators OBJECT-TYPE SYNTAX Integer32 (0..16) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable" ::= { prtInPh1MlCnfgEntry 22} prtInPh1MlCcittCrc OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), crc16 (2), crc32 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates how many Bits are used for CRC (HDLC item)." ::= { prtInPh1MlCnfgEntry 23} prtInPh1MlFrameSeparator OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), idles (2), flags (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line." ::= { prtInPh1MlCnfgEntry 24} -- -- MPH1.T1 & MPH1.E1 -- Internal port Dlci objects table -- prtInPh1MlDlciTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInPh1MlDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtPh1MlCnfg 4} prtInPh1MlDlciEntry OBJECT-TYPE SYNTAX PrtInPh1MlDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInPh1MlDlciCnfgIdx, prtInPh1MlDlciSltIdx, prtInPh1MlDlciPrtIdx, prtInPh1MlDlciIdx } ::= { prtInPh1MlDlciTable 1} PrtInPh1MlDlciEntry ::= SEQUENCE { prtInPh1MlDlciCnfgIdx Integer32, prtInPh1MlDlciSltIdx INTEGER, prtInPh1MlDlciPrtIdx INTEGER, prtInPh1MlDlciIdx Integer32, prtInPh1MlDlciValid INTEGER, prtInPh1MlDlciIConSlt INTEGER, prtInPh1MlDlciIConPrt INTEGER, prtInPh1MlDlciIConDlci Integer32, prtInPh1MlDlciTxBc INTEGER, prtInPh1MlDlciTxBe INTEGER, prtInPh1MlDlciRxBc INTEGER, prtInPh1MlDlciRxBe INTEGER, prtInPh1MlDlciPriority Integer32, prtInPh1MlDlciStatus INTEGER } prtInPh1MlDlciCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtInPh1MlDlciEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtInPh1MlDlciSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtInPh1MlDlciEntry 2} prtInPh1MlDlciPrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) , inPrt2 (102) , inPrt3 (103) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal port number. MPH.1/E1 and MPH.1/T1 cards have three internal ports." ::= { prtInPh1MlDlciEntry 3} prtInPh1MlDlciIdx OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, then its type is 'user' and the only valid index is 1." ::= { prtInPh1MlDlciEntry 4} prtInPh1MlDlciValid OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object" ::= { prtInPh1MlDlciEntry 5} prtInPh1MlDlciIConSlt OBJECT-TYPE SYNTAX INTEGER { noConnect(2), cl (3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtInPh1MlDlciEntry 6} prtInPh1MlDlciIConPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , clNMS (99) , noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port id which the dlci is routed to." ::= { prtInPh1MlDlciEntry 7} prtInPh1MlDlciIConDlci OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique internal connection dlci number which the src dlci is routed to." ::= { prtInPh1MlDlciEntry 8} prtInPh1MlDlciTxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBc9600bps (3), txBc14200bps (4), txBc19200bps (5), txBc28800bps (6), txBc32000bps (7), txBc38400bps (8), txBc48000bps (9), txBc56000bps (10), txBc57600bps (11), txBc64Kbps (12), txBc128Kbps (13), txBc192Kbps (14), txBc256Kbps (15), txBc320Kbps (16), txBc384Kbps (17), txBc448Kbps (18), txBc512Kbps (19), txBc768Kbps (20), txBc1024Kbps (21) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx committed bandwidth on the user transmit line or at the port receive line." ::= { prtInPh1MlDlciEntry 9} prtInPh1MlDlciTxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBe9600bps (3), txBe14200bps (4), txBe19200bps (5), txBe28800bps (6), txBe32000bps (7), txBe38400bps (8), txBe48000bps (9), txBe56000bps (10), txBe57600bps (11), txBe64Kbps (12), txBe128Kbps (13), txBe192Kbps (14), txBe256Kbps (15), txBe320Kbps (16), txBe384Kbps (17), txBe448Kbps (18), txBe512Kbps (19), txBe768Kbps (20), txBe1024Kbps (21) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx excess bandwidth on the user transmit line or at the port receive line." ::= { prtInPh1MlDlciEntry 10} prtInPh1MlDlciRxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBc9600bps (3), rxBc14200bps (4), rxBc19200bps (5), rxBc28800bps (6), rxBc32000bps (7), rxBc38400bps (8), rxBc48000bps (9), rxBc56000bps (10), rxBc57600bps (11), rxBc64Kbps (12), rxBc128Kbps (13), rxBc192Kbps (14), rxBc256Kbps (15), rxBc320Kbps (16), rxBc384Kbps (17), rxBc448Kbps (18), rxBc512Kbps (19), rxBc768Kbps (20), rxBc1024Kbps (21) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx committed bandwidth on the user receive line or at the port transmit line." ::= { prtInPh1MlDlciEntry 11} prtInPh1MlDlciRxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBe9600bps (3), rxBe14200bps (4), rxBe19200bps (5), rxBe28800bps (6), rxBe32000bps (7), rxBe38400bps (8), rxBe48000bps (9), rxBe56000bps (10), rxBe57600bps (11), rxBe64Kbps (12), rxBe128Kbps (13), rxBe192Kbps (14), rxBe256Kbps (15), rxBe320Kbps (16), rxBe384Kbps (17), rxBe448Kbps (18), rxBe512Kbps (19), rxBe768Kbps (20), rxBe1024Kbps (21) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx excess bandwidth on the user receive line or at the port transmit line." ::= { prtInPh1MlDlciEntry 12} prtInPh1MlDlciPriority OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority." ::= { prtInPh1MlDlciEntry 13} prtInPh1MlDlciStatus OBJECT-TYPE SYNTAX INTEGER { disconnected (1), connected (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected" ::= { prtInPh1MlDlciEntry 14} -- -- ML-20 - High Speed Main Link card -- External Port Objects -- prtPhMlCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtPhMlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtPh1MlCnfg 5} prtPhMlCnfgEntry OBJECT-TYPE SYNTAX PrtPhMlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtPhMlCnfgIdx, prtPhMlSltIdx, prtPhMlPrtIdx } ::= { prtPhMlCnfgTable 1} PrtPhMlCnfgEntry ::= SEQUENCE { prtPhMlCnfgIdx Integer32, prtPhMlSltIdx INTEGER, prtPhMlPrtIdx INTEGER, prtPhMlConnect INTEGER, prtPhMlRate INTEGER, prtPhMlCAS INTEGER, prtPhMlClockMode INTEGER, prtPhMlSatBuffer INTEGER, prtPhMlDialProcess INTEGER, prtPhMlSyncRestore Integer32, prtPhMlBus INTEGER, prtPhMlMfSyncSlot INTEGER, prtPhMlClockSource INTEGER, prtPhMlErrCorrection INTEGER, prtPhMlCorrectionMode INTEGER, prtPhMlControlSignals INTEGER, prtPhMlInterfaceType INTEGER, prtPhMlClockPolarity INTEGER } prtPhMlCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtPhMlCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtPhMlSltIdx OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For the Vmux2100 Main Board notApplicable (1) is used." ::= { prtPhMlCnfgEntry 2} prtPhMlPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. ML-20 cards have just one external interface." ::= { prtPhMlCnfgEntry 3} prtPhMlConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtPhMlCnfgEntry 4} prtPhMlRate OBJECT-TYPE SYNTAX INTEGER { r1x64eq64Kbps (2), r2x64eq128Kbps (4), r3x64eq192Kbps (6), r4x64eq256Kbps (8), r5x64eq320Kbps (10), r6x64eq384Kbps (12), r7x64eq448Kbps (14), r8x64eq512Kbps (16), r9x64eq576Kbps (18), r10x64eq640Kbps (20), r11x64eq704Kbps (22), r12x64eq768Kbps (24), r13x64eq832Kbps (26), r14x64eq896Kbps (28), r15x64eq960Kbps (30), r16x64eq1024Kbps(32), r17x64eq1088Kbps(34), r18x64eq1152Kbps(36), r19x64eq1216Kbps(38), r20x64eq1280Kbps(40), r21x64eq1344Kbps(42), r22x64eq1408Kbps(44), r23x64eq1472Kbps(46), r24x64eq1536Kbps(48), r25x64eq1600Kbps(50), r26x64eq1664Kbps(52), r27x64eq1728Kbps(54), r28x64eq1792Kbps(56), r29x64eq1856Kbps(58), r30x64eq1920Kbps(60), r31x64eq1984Kbps(62), r32x64eq2048Kbps(64), auto (70) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the configured port speed. auto - rate is adapted automatically to the attached modem rate." ::= {prtPhMlCnfgEntry 5} prtPhMlCAS OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether Channel Associated Signaling (CAS) is used." ::= {prtPhMlCnfgEntry 6} prtPhMlClockMode OBJECT-TYPE SYNTAX INTEGER { dce (2), ext-dce (3), dte (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock mode." ::= { prtPhMlCnfgEntry 7} prtPhMlSatBuffer OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Satellite Buffer (+/- 256)." ::= {prtPhMlCnfgEntry 8} prtPhMlDialProcess OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), callIn (3), callOut (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Dial Process." ::= {prtPhMlCnfgEntry 9} prtPhMlSyncRestore OBJECT-TYPE SYNTAX Integer32 (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Sync Restoration time, in seconds. notApplicable=0. " ::= {prtPhMlCnfgEntry 10} prtPhMlBus OBJECT-TYPE SYNTAX INTEGER { none (1), busA (2), busB (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The TDM BUS this port is linked to." ::= {prtPhMlCnfgEntry 11} prtPhMlMfSyncSlot OBJECT-TYPE SYNTAX INTEGER { none (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the sync is synchronized according to a certain card and the slot of this card. This operation is required in order to bypass signaling of PCM voice channels. In the ?004 Unit the entries io6(10)..io12(16) are not valid" ::= {prtPhMlCnfgEntry 12} prtPhMlClockSource OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), txClock (2), rxClock (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Clock Source: TC (Tx Clock) or RC (Rx Clock) signals." ::= {prtPhMlCnfgEntry 13} prtPhMlErrCorrection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if Error Correction mechanism should be applied or not. It will be applicable only if the interface HW includes the Error Correction chip." ::= {prtPhMlCnfgEntry 14} prtPhMlCorrectionMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), random (2), bursty (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only when prtPhMlErrCorrection=yes. random - enables to correct up to 3 random errors in an 23 bit frame built from 12 data bits and 11 appended parity bits. bursty - interleaving 3 frames, allows correcting bursts of 9 bit length." ::= {prtPhMlCnfgEntry 15} prtPhMlControlSignals OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), ignore (2), implement (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object shows whether the Port will ignore or implement the control signals like DCD, CTS, DTR." ::= {prtPhMlCnfgEntry 16} prtPhMlInterfaceType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), v35 (2), x21 (3), -- v.11 rs232 (4), -- v.28 rs449 (5), ei530 (6), ei530a (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "The SW Configurable Interface Type." ::= {prtPhMlCnfgEntry 17} prtPhMlClockPolarity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), normal (2), inverted (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the clock polarity." ::= {prtPhMlCnfgEntry 18} -- This table is an extension for new version of MAXcess -- modules. prtLogicalCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtLogicalCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLogicalCnfg 1} prtLogicalCnfgEntry OBJECT-TYPE SYNTAX PrtLogicalCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtLogicalCnfgIdx, prtLogicalSltIdx, prtLogicalPrtIdx } ::= { prtLogicalCnfgTable 1} PrtLogicalCnfgEntry ::= SEQUENCE { prtLogicalCnfgIdx Integer32, prtLogicalSltIdx INTEGER, prtLogicalPrtIdx Integer32, prtLogicalConnect INTEGER, prtLogicalFunction INTEGER, prtLogicalRowStatus RowStatus } prtLogicalCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtLogicalCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtLogicalSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6)." ::= { prtLogicalCnfgEntry 2} prtLogicalPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. This port number should be an internal port number: inPrt1(101)->inPrt50(150), linkSel1(200)->linkSel50(250), encaps1(300)-> encaps50(350), huntGr1(101) -> huntGr10(110)." ::= { prtLogicalCnfgEntry 3} prtLogicalConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-create STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= { prtLogicalCnfgEntry 4} prtLogicalFunction OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), linkSelector(2), encapsulator(3), huntGroup(4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter defines the function of the relevant channel." ::= { prtLogicalCnfgEntry 5 } prtLogicalRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This parameter allows the NMS to create/delete logical ports. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { prtLogicalCnfgEntry 6 } -- This group contains management information for the -- link selector function. linkSelectorCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkSelectorCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtLogicalCnfg 2} linkSelectorCnfgEntry OBJECT-TYPE SYNTAX LinkSelectorCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {linkSelectorCnfgIdx, linkSelectorSltIdx, linkSelectorPrtIdx } ::= { linkSelectorCnfgTable 1} LinkSelectorCnfgEntry ::= SEQUENCE { linkSelectorCnfgIdx Integer32, linkSelectorSltIdx INTEGER, linkSelectorPrtIdx Integer32, linkSelectorMaxIdleTime Integer32, linkSelectorMode INTEGER, linkSelectorRevert INTEGER, linkSelectorMinBUSession Integer32 } linkSelectorCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { linkSelectorCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. linkSelectorSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index" ::= { linkSelectorCnfgEntry 2} linkSelectorPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. This port number should be internal port number: higher or equal to linkSeL1(201)." ::= { linkSelectorCnfgEntry 3} linkSelectorMaxIdleTime OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Move to higher prioritized connected link after this period of seconds of silence on the current link. 0=move immediately to higher prioritized connected link. UNIT is seconds." DEFVAL { 0 } ::= {linkSelectorCnfgEntry 4} linkSelectorMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), backup(2), bod(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " If the link selector is in mode: backup(2)=then the link with the lower priority will be used in case of failure of the higher priority link, bod(3)=bandwidth on demand or dynamic bandwidth allocation means that links with lower priority will be used whenever additional bandwidth is required. " DEFVAL { backup } ::= {linkSelectorCnfgEntry 5} linkSelectorRevert OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), auto(2), manual(3) } MAX-ACCESS read-write STATUS current DESCRIPTION " If the link selector is in mode backup: auto(2)=return automatically to Main link when it is OK. manual(3)=stays connected to backup link." DEFVAL { auto } ::= {linkSelectorCnfgEntry 6} linkSelectorMinBUSession OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum duration of a backup session before returning to Main Link. Relevant in Backup Mode and when Revert is auto(2). Value 255 is for NEVER which means never return to Main Link. UNIT is minutes." DEFVAL { 10 } ::= {linkSelectorCnfgEntry 7} -- Prioritized Links linkSelectorPLinkTable OBJECT-TYPE SYNTAX SEQUENCE OF LinkSelectorPLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtLogicalCnfg 3} linkSelectorPLinkEntry OBJECT-TYPE SYNTAX LinkSelectorPLinkEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {pLinkCnfgIdx, pLinkSltIdx, pLinkPrtIdx, pLinkIdx } ::= { linkSelectorPLinkTable 1} LinkSelectorPLinkEntry ::= SEQUENCE { pLinkCnfgIdx Integer32, pLinkSltIdx INTEGER, pLinkPrtIdx Integer32, pLinkIdx Integer32, pLinkSlotNu INTEGER, pLinkPortNu Integer32, pLinkPrioNu Integer32, pLinkVRate INTEGER } pLinkCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { linkSelectorPLinkEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. pLinkSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index" ::= { linkSelectorPLinkEntry 2} pLinkPrtIdx OBJECT-TYPE SYNTAX Integer32(200..250) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. This port number should be the link selector number." ::= { linkSelectorPLinkEntry 3} pLinkIdx OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-only STATUS current DESCRIPTION "This index is the row number." ::= { linkSelectorPLinkEntry 4} pLinkSlotNu OBJECT-TYPE SYNTAX INTEGER { noConnect (2), cl(3), io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The slot of the prioritized link. For ISDN BRI ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6)." DEFVAL { noConnect } ::= { linkSelectorPLinkEntry 5 } pLinkPortNu OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The port of the prioritized link. Value 100 is for noConnect." DEFVAL { 100 } ::= { linkSelectorPLinkEntry 6 } pLinkPrioNu OBJECT-TYPE SYNTAX Integer32(1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "The priority of the prioritized link. MIN=1...., MAX=8." ::= { linkSelectorPLinkEntry 7 } pLinkVRate OBJECT-TYPE SYNTAX INTEGER { r1x56eq56Kbps (1), r1x64eq64Kbps (2), r2x56eq112Kbps (3), r2x64eq128Kbps (4), r3x56eq168Kbps (5), r3x64eq192Kbps (6), r4x56eq224Kbps (7), r4x64eq256Kbps (8), r5x56eq280Kbps (9), r5x64eq320Kbps (10), r6x56eq336Kbps (11), r6x64eq384Kbps (12), r7x56eq392Kbps (13), r7x64eq448Kbps (14), r8x56eq448Kbps (15), r8x64eq512Kbps (16), r9x56eq504Kbps (17), r9x64eq576Kbps (18), r10x56eq560Kbps (19), r10x64eq640Kbps (20), r11x56eq616Kbps (21), r11x64eq704Kbps (22), r12x56eq672Kbps (23), r12x64eq768Kbps (24), r13x56eq728Kbps (25), r13x64eq832Kbps (26), r14x56eq784Kbps (27), r14x64eq896Kbps (28), r15x56eq840Kbps (29), r15x64eq960Kbps (30), r16x56eq896Kbps (31), r16x64eq1024Kbps(32), r17x56eq952Kbps (33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), noRate(100) } MAX-ACCESS read-write STATUS current DESCRIPTION "The rate to use with this link." DEFVAL { noRate } ::= { linkSelectorPLinkEntry 8 } -- -- Megaplex or Kilomux ?000/?004 MPH.1/3 High speed packet data cards. -- Megaplex or Kilomux ?000/?004 MPL.6 Low speed packet data cards. -- (Mph1, Mph3, Mpl6) -- Maxcess 3000/3004 MLS-3/6, MHS-1/3 -- -- prtExPhPlCnfgTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 1} -- prtExPhPlDlciTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 2} -- prtExPhPlModemTable OBJECT IDENTIFIER ::= {prtPhPlCnfg 3} -- Mph.1 Mph.3 Mpl.6/ Kphs.1 Kphs.3 Mls.3 Mls.6 Mhs.1 Mhs.3 -- External port objects table prtExPhPlCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPhPlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtPhPlCnfg 1} prtExPhPlCnfgEntry OBJECT-TYPE SYNTAX PrtExPhPlCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPhPlCnfgIdx, prtExPhPlSltIdx, prtExPhPlPrtIdx} ::= { prtExPhPlCnfgTable 1} PrtExPhPlCnfgEntry ::= SEQUENCE { prtExPhPlCnfgIdx Integer32, prtExPhPlSltIdx INTEGER, prtExPhPlPrtIdx INTEGER, prtExPhPlConnect INTEGER, prtExPhPlHRate INTEGER, prtExPhPlLRate INTEGER, prtExPhPlProtocol INTEGER, prtExPhPlConnectionTyp INTEGER, prtExPhPlClkMode INTEGER, prtExPhPlDceClkSrc INTEGER, prtExPhPlCongResponse INTEGER, prtExPhPlCongLevel Integer32, prtExPhPlTc INTEGER, prtExPhPlFlowControl INTEGER, prtExPhPlDcdRts INTEGER, prtExPhPlDcdRtsControlPath INTEGER, prtExPhPlDataBits INTEGER, prtExPhPlParity INTEGER, prtExPhPlStopBits INTEGER, prtExPhPlLXon Integer32, prtExPhPlLXoff Integer32, prtExPhPlFrMngProt INTEGER, prtExPhPlEnqPeriod Integer32, prtExPhPlFullRptPeriod Integer32, prtExPhPlFrWindowSize Integer32, prtExPhPlErrorsThreshold Integer32, prtExPhPlPvcCreateMsg INTEGER, prtExPhPlCllmMsg INTEGER, prtExPhPlProtDelayLevel INTEGER, prtExPhPlClockEncoding INTEGER, prtExPhPlMinSeparators Integer32, prtExPhPlCcittCrc INTEGER, prtExPhPlFrameSeparator INTEGER, prtExPhPlIdleCode Integer32, prtExPhPlJitter Integer32 } prtExPhPlCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPhPlCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPhPlSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid" ::= { prtExPhPlCnfgEntry 2} prtExPhPlPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid." ::= { prtExPhPlCnfgEntry 3} prtExPhPlConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= { prtExPhPlCnfgEntry 4} prtExPhPlHRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r32KbpsNLE (2), r48KbpsNLE (3), r56KbpsNLE (4), r64KbpsNLE (5), r112KbpsNLE (6), r128KbpsNLE (7), r168KbpsNLE (8), r192KbpsNLE (9), r224KbpsNLE (10), r256KbpsNLE (11), r280KbpsE (12), r320KbpsE (13), r336KbpsNLE (14), r384KbpsNLE (15), r392KbpsE (16), r448KbpsNLE (17), r504KbpsLE (18), -- r504KbpsE r512KbpsE (19), -- r512KbpsNLE r560KbpsE (20), r576KbpsLE (21), -- r576KbpsE r616KbpsE (22), r640KbpsE (23), r672KbpsNLE (24), r704KbpsE (25), r728KbpsE (26), r768KbpsNLE (27), r784KbpsE (28), r832KbpsE (29), r840KbpsE (30), r896KbpsNLE (31), r952KbpsE (32), r960KbpsE (33), r1008KbpsLE (34), -- r1008KbpsE r1024KbpsE (35), -- r1024KbpsNLE r1064KbpsE (36), r1088KbpsE (37), r1120KbpsE (38), r1152KbpsLE (39), -- r1152KbpsE r1176KbpsE (40), r1216KbpsE (41), r1232KbpsE (42), r1280KbpsE (43), r1288KbpsE (44), r1344KbpsNLE (45), r1400KbpsE (46), r1408KbpsE (47), r1456KbpsE (48), r1472KbpsE (49), r1512KbpsE (50), r1536KbpsE (51), -- r1536KbpsNLE r1568KbpsE (52), r1600KbpsE (53), r1624KbpsE (54), r1664KbpsE (55), r1680KbpsE (56), r1728KbpsE (57), r1736KbpsE (58), r1792KbpsNLE (59), r1856KbpsE (60), r1920KbpsE (61), r1984KbpsE (62), r2048KbpsE (63), -- r2048KbpsNLE -- -- Additional rates for: MAXcess, MP2100h -- r9d6KbpsNLE (65), r14d4KbpsNLE (66), r16KbpsNLE (67), r19d2KbpsNLE (68), r28d8KbpsNLE (69), r38d4KbpsNLE (70), r57d6KbpsNLE (71), -- For Mx 30/300 Only r115d2KbpsNLE (72), -- For Mx 30/300 Only r24000bps (73) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed for HIGH speed cards. The card has limitations about the maximum sigma channel speeds and about the possible rates for each clock mode . N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. 'r9d6KbpsNLE' means rate of 9.6 Kbps ('d'=dot). Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r2048KbpsE (63), -- r2048KbpsNLE" ::= { prtExPhPlCnfgEntry 5} prtExPhPlLRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r300bpsNLE (2), r600bpsNLE (3), r800bpsNLE (4), r1200bpsNLE (5), r2400bpsNLE (6), r4800bpsNLE (7), r9600bpsNLE (8), r14400bpsLE (9), -- r14400bpsNLE r19200bpsNLE (10), r28800bpsLE (11), -- r28800bpsNLE r32000bpsNLE (12), r38400bpsNLE (13), r48000bpsNLE (14), r56000bpsNLE (15), r57600bpsLE (16), -- r57600bpsNLE r64000bpsNLE (17), r112000bps (18), -- For Mx 30/300 Only: r112000bpsNLE r115200bps (19), -- For Mx 30/300 Only: r115200bpsNLE -- -- additional rates -- r16000bpsNLE (20), r100bpsNLE (21), -- For Mx 30/300 Only r128000bps (22), -- For Mx 30/300 Only r24000bps (23) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed for LOW speed cards. The card has limitations about the possible rates for each clock mode. N - The rate is valid for DCE and EXT-DCE Nodal clock mode. L - The rate is valid for DCE and EXT-DCE Local clock mode. E - The rate is valid for DTE External clock mode. Note: Some rate attributes have been changed. As the MIB was already released with the old attributes, the names of the options were not changed. The new names + attributes are in a comment. Example: r57600bpsLE (16), -- r57600bpsNLE " ::= { prtExPhPlCnfgEntry 6} prtExPhPlProtocol OBJECT-TYPE SYNTAX INTEGER { fr (1), frPlus (2), pCellRelay (3), hdlcSdlc (4), transparentHdlc (5), async (6), asyncReliable (7), activePPP (8), slip (9), pppAgent (10), slipAgent (11), transparent (12), sna (13), ft1Dot2 (14) -- Standard IEC 870-5-1 for Frame Transport } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the applied protocol." ::= { prtExPhPlCnfgEntry 7} prtExPhPlConnectionTyp OBJECT-TYPE SYNTAX INTEGER { sameNetManaged (1), sameNetNotMana (2), user (3), otherNet (4), pubNet (5), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the link connection type. It is required for three reasons: FR/CR Inband management opration (LMI,CLMM...). CIR check. NMS network management. SameNetManaged - indicates network internal line. SameNetMotMana - indicates network internal line, but the remote mux is not managed by the NMS. User - User to Network Interface. OtherNet - Network To Network Interface. PubNet - Access Mux To PubNet Interface." ::= { prtExPhPlCnfgEntry 8} prtExPhPlClkMode OBJECT-TYPE SYNTAX INTEGER { dce (1), extDce (2), dte (3), int (4), lbt (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock mode." ::= { prtExPhPlCnfgEntry 9} prtExPhPlDceClkSrc OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), local (2), nodalTiming (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the source of the clock when working in dce or ext-dce clock mode. notApplicable(1) - is applied for dte(3) and lbt(5) clock modes. When clock mode is dte, the clock source is always external, therefore this object's value is notApplicable. local(2) and nodalTiming(3) - are valid in dce(1), extDce(2) or int(4) clock modes. The recommended clock source is local(2)." ::= { prtExPhPlCnfgEntry 10} prtExPhPlCongResponse OBJECT-TYPE SYNTAX INTEGER { no (2), flowControl (3), -- duplex, to/from flow control toFlowControl (4) -- simplex , only to flow control } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates how to handle the congestion indication to/from the mux internal connection side (for example transmit/received becn to/from the network). no - do nothing flowControl - translates the congestion indication between the port and the internal connection port according to the definition of the prtInPh1MlFlowControl parameters. The operation is done on both directions. toFlowControl- translates the backward congestion indication received from the internal connection port (normally the network side) to flow control and do nothing in the other direction." ::= { prtExPhPlCnfgEntry 11} prtExPhPlCongLevel OBJECT-TYPE SYNTAX Integer32 (0..70) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5 percent." ::= { prtExPhPlCnfgEntry 12} prtExPhPlTc OBJECT-TYPE SYNTAX INTEGER { tc1sec (1), tc2sec (2), tc3sec (3), tc4sec (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Tc parameter which is the time period of the sliding window in which the Bc/Be are tested. The value of this parameter is identical for all the ports of a specific card ." ::= { prtExPhPlCnfgEntry 13} prtExPhPlFlowControl OBJECT-TYPE SYNTAX INTEGER { none (2), fecnBecn (3), xonXoff (4), dtrCts (5), speedReduction (6) -- simplex response only congestion to flow control } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the required flow control betweeen the port and the remote equipment. fecnBecn - is valid only for FR, FR+ and CR protocols. xonXoff,dtrCts - are valid only for Async protocols. speedReduction - is valid only for DLC protocol when the Clock Mode is DCE and the Clock Source is Local." ::= { prtExPhPlCnfgEntry 14} prtExPhPlDcdRts OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), endToEnd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Protocol may require end to end connect indication over the network. End to end link connection establishment over the FR network will be indicated to the user by using DCD or RTS control signals, depending on the clock mode: DCE or DTE respectively. The options are : - On : DCD(DCE)/RTS(DTE) will be constantly ON no matter if the End to End connection is established or not. - End to End: The DCD(DCE)/RTS(DTE) will be according to the status of the End to End connection." ::= { prtExPhPlCnfgEntry 15} prtExPhPlDcdRtsControlPath OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Protocol may require end to end connect indication over the network. This parameter defines whether to take the user connection status (RTS(DCE)/DCD(DTE)) and forward it to the network side. - on : Transmit active connection to the network regardless the RTS/DCD control lines status. - off: Transmit active connection to the network according to the status of the RTS/DCD pin. " ::= { prtExPhPlCnfgEntry 16} prtExPhPlDataBits OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), dataBits7Bits (2), dataBits8Bits (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the number of data bits in async frame. It is relevant only for Async protocols." ::= { prtExPhPlCnfgEntry 17} prtExPhPlParity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), odd (2), even (3), none (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the parity operation mode in async frame. It is relevant only for Async protocols." ::= { prtExPhPlCnfgEntry 18} prtExPhPlStopBits OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), sb1Bit (2), sb1dot5Bits (3), sb2Bits (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the minimum number of stop bits in the tx async frame. It is relevant only for Async protocols." ::= { prtExPhPlCnfgEntry 19} prtExPhPlLXon OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the character used as X-On to notify receive enable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable " ::= { prtExPhPlCnfgEntry 20} prtExPhPlLXoff OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the character used as X-Off to notify receive disable. This parameter is valid only for async protocols. Valid values: 0..255. The value 256 indicates that it's not applicable " ::= { prtExPhPlCnfgEntry 21} prtExPhPlFrMngProt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), lmi (3), ansiT1 (4), --Annex D annexA (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Frame-Relay management protocol. ansiT1 = ANSI T1.617 Annex D (this is the default value). This parameter is applicable only for FR and FR+ protocols. When prtExPhPlConnectionTyp = sameNetManaged, this object will be RO (internally determined). " ::= { prtExPhPlCnfgEntry 22} prtExPhPlEnqPeriod OBJECT-TYPE SYNTAX Integer32 (1..30) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Status Enquiry Period, in seconds. It determines the frequency of the Status Enquiry message as sent by the FR user side. At the FR network side, it determines the timeout for this message reception. Default = 4 seconds. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 23} prtExPhPlFullRptPeriod OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Full Report Frequency. It determines the number of the Status Enquiry messages sent by the FR user side, before a Full Report Request is sent. The units are : Status Enquiry messages (periods). Valid values: 1 .. 255. 255 = infinite. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 24} prtExPhPlFrWindowSize OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the FR Window Size. It determines the number of samplings in the sliding window that counts the errors. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 25} prtExPhPlErrorsThreshold OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Max Errors. It determines the number of Status Enquiry Errors that occured within the FR sliding window, before this port is considered DOWN (threshold). This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 26} prtExPhPlPvcCreateMsg OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is Update Message (if required or not). It determines whether a message of a New PVC Creation is requested or not (yes/no). Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 27} prtExPhPlCllmMsg OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is CLLM Message (if required or not). It determines whether to send (or not) a congestion message when the port is Rx congested. Default = no. This parameter is applicable only for FR and FR+ protocols AND only when prtExPhPlFrMngProt is NOT (notApplicable or none)." ::= { prtExPhPlCnfgEntry 28} prtExPhPlProtDelayLevel OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), s36Byte (2), --level 1 s150Byte (3), --level 2 s264Byte (4), --level 3 s378Byte (5), --level 4 s492Byte (6) --level 5 } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Segmentation in Bytes. In some cases, the enumerated values will mean other segmentation values than specified: Product: MX-3000 MX-3000 MX-300/MX-30 Protocol: FR+ Transparent FR+ ----------------------------------------------------- level 1 50 Bytes 44 Bytes 50 Bytes level 2 158 Bytes 155 Bytes 158 Bytes level 3 266 Bytes 266 Bytes 266 Bytes level 4 376 Bytes 377 Bytes 376 Bytes level 5 484 Bytes 488 Bytes 484 Bytes Defval=level 1 value This parameter is applicable only for FR+ and transparent protocols." ::= { prtExPhPlCnfgEntry 29} prtExPhPlClockEncoding OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), nrz (2), nrzI (3), fm0 (4), manchester (5), diffManchester(6), nrzISpace (7), nrzIMark (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the Encoding type of the Line. This parameter is applicable only for FR and FR+ protocols. For MAXCESS 3000 & MP2100H: when setting to nrzI (3) the nrzI works as nrzI Mark. For MAXCESS 30/300 when setting to nrzI (3) the nrzI works as nrzI Space." ::= { prtExPhPlCnfgEntry 30} prtExPhPlMinSeparators OBJECT-TYPE SYNTAX Integer32 (0..16) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum number of bytes separating between two adjacent frames (HDLC item). 0 = notApplicable" ::= { prtExPhPlCnfgEntry 31} prtExPhPlCcittCrc OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), crc16 (2), crc32 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates how many Bits are used for CRC (HDLC item)." ::= { prtExPhPlCnfgEntry 32} prtExPhPlFrameSeparator OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), idles (2), flags (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates what should be transferred on the line when there are no frames to pass (HDLC item). idles: mean that FF will pass on the line flags: mean that 7E will pass on the line." ::= { prtExPhPlCnfgEntry 33} prtExPhPlIdleCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the code for transmission when there are no frames to transmit on the line. The value should be 0 to FFH." ::= { prtExPhPlCnfgEntry 34} prtExPhPlJitter OBJECT-TYPE SYNTAX Integer32 (0..1000) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum variant delay of the FR network, in msec." ::= { prtExPhPlCnfgEntry 35} -- -- PH.1 & PH.3 -- External port Dlci table -- prtExPhPlDlciTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPhPlDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only at the TmpCnfg entry." ::= {prtPhPlCnfg 2} prtExPhPlDlciEntry OBJECT-TYPE SYNTAX PrtExPhPlDlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPhPlDlciCnfgIdx, prtExPhPlDlciSltIdx, prtExPhPlDlciPrtIdx, prtExPhPlDlciIdx } ::= { prtExPhPlDlciTable 1} PrtExPhPlDlciEntry ::= SEQUENCE { prtExPhPlDlciCnfgIdx Integer32, prtExPhPlDlciSltIdx INTEGER, prtExPhPlDlciPrtIdx INTEGER, prtExPhPlDlciIdx Integer32, prtExPhPlDlciValid INTEGER, prtExPhPlDlciIConSlt INTEGER, prtExPhPlDlciIConPrt INTEGER, prtExPhPlDlciIConDlci Integer32, prtExPhPlDlciTxBc INTEGER, prtExPhPlDlciTxBe INTEGER, prtExPhPlDlciRxBc INTEGER, prtExPhPlDlciRxBe INTEGER, prtExPhPlDlciPriority Integer32, prtExPhPlDlciStatus INTEGER } prtExPhPlDlciCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPhPlDlciEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPhPlDlciSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtExPhPlDlciEntry 2} prtExPhPlDlciPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal port number. PH.1/E1 and PH.1/T1 cards have three internal ports. Stand-alone units may have six such ports." ::= { prtExPhPlDlciEntry 3} prtExPhPlDlciIdx OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique index for each possible used dlci(16..991). When the protocol is not Multiplexing protocol, its type is 'user' and the only valid index is 1." ::= { prtExPhPlDlciEntry 4} prtExPhPlDlciValid OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object" ::= { prtExPhPlDlciEntry 5} prtExPhPlDlciIConSlt OBJECT-TYPE SYNTAX INTEGER { noConnect (2), cl (3), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. cl - will represent any of the CL slots. This value can be selected for multiple DLCIs of the product. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtExPhPlDlciEntry 6} prtExPhPlDlciIConPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , clNMS (99), noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port id which the dlci is routed to. clNMS - will be used for NMS SNMP messages. It can be any port of the CL card. This value will be selectable only if prtExPhPlDlciIConSlt='cl' or 'notApplicable'." ::= { prtExPhPlDlciEntry 7} prtExPhPlDlciIConDlci OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique internal connection dlci number, the dlci is routed to." ::= { prtExPhPlDlciEntry 8} prtExPhPlDlciTxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBc9600bps (3), txBc14400bps (4), txBc19200bps (5), txBc28800bps (6), txBc32000bps (7), txBc38400bps (8), txBc48000bps (9), txBc56000bps (10), txBc57600bps (11), txBc64Kbps (12), txBc128Kbps (13), txBc192Kbps (14), txBc256Kbps (15), txBc320Kbps (16), txBc384Kbps (17), txBc448Kbps (18), txBc512Kbps (19), txBc768Kbps (20), txBc1024Kbps (21), -- --KM30 ; KM300 additional rates -- txBc16000bps (25), txBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line)." ::= { prtExPhPlDlciEntry 9} prtExPhPlDlciTxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBe9600bps (3), txBe14400bps (4), txBe19200bps (5), txBe28800bps (6), txBe32000bps (7), txBe38400bps (8), txBe48000bps (9), txBe56000bps (10), txBe57600bps (11), txBe64Kbps (12), txBe128Kbps (13), txBe192Kbps (14), txBe256Kbps (15), txBe320Kbps (16), txBe384Kbps (17), txBe448Kbps (18), txBe512Kbps (19), txBe768Kbps (20), txBe1024Kbps (21), -- --KM30 ; KM300 additional rates -- txBc16000bps (25), txBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line)." ::= { prtExPhPlDlciEntry 10} prtExPhPlDlciRxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBc9600bps (3), rxBc14400bps (4), rxBc19200bps (5), rxBc28800bps (6), rxBc32000bps (7), rxBc38400bps (8), rxBc48000bps (9), rxBc56000bps (10), rxBc57600bps (11), rxBc64Kbps (12), rxBc128Kbps (13), rxBc192Kbps (14), rxBc256Kbps (15), rxBc320Kbps (16), rxBc384Kbps (17), rxBc448Kbps (18), rxBc512Kbps (19), rxBc768Kbps (20), rxBc1024Kbps (21), -- --KM30 ; KM300 additional rates -- rxBc16000bps (25), rxBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line)." ::= { prtExPhPlDlciEntry 11} prtExPhPlDlciRxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBe9600bps (3), rxBe14400bps (4), rxBe19200bps (5), rxBe28800bps (6), rxBe32000bps (7), rxBe38400bps (8), rxBe48000bps (9), rxBe56000bps (10), rxBe57600bps (11), rxBe64Kbps (12), rxBe128Kbps (13), rxBe192Kbps (14), rxBe256Kbps (15), rxBe320Kbps (16), rxBe384Kbps (17), rxBe448Kbps (18), rxBe512Kbps (19), rxBe768Kbps (20), rxBe1024Kbps (21), -- --KM30 ; KM300 additional rates -- rxBc16000bps (25), rxBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line)." ::= { prtExPhPlDlciEntry 12} prtExPhPlDlciPriority OBJECT-TYPE SYNTAX Integer32 (1..8) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique priority of the pcv. 1 is the lowest priority and 8 is the highest priority." ::= { prtExPhPlDlciEntry 13} prtExPhPlDlciStatus OBJECT-TYPE SYNTAX INTEGER { disconnected (1), connected (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected" ::= { prtExPhPlDlciEntry 14} -- Parameters of an external Modem which is connected to a High/Low Speed -- Port. prtExPhPlModemTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPhPlModemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "External Modem Parameters. The write operation into the Table Objects is valid only for the TmpCnfg entry." ::= {prtPhPlCnfg 3} prtExPhPlModemEntry OBJECT-TYPE SYNTAX PrtExPhPlModemEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPhPlModemCnfgIdx,prtExPhPlModemSltIdx,prtExPhPlModemPrtIdx} ::= { prtExPhPlModemTable 1} PrtExPhPlModemEntry ::= SEQUENCE { prtExPhPlModemCnfgIdx Integer32, prtExPhPlModemSltIdx INTEGER, prtExPhPlModemPrtIdx INTEGER, prtExPhPlModemStatus INTEGER, prtExPhPlModemActivate INTEGER, prtExPhPlModemMaxIdleTime Integer32, prtExPhPlModemTimeBtwnCalls Integer32, prtExPhPlModemCallDelay Integer32 } prtExPhPlModemCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPhPlModemEntry 1} prtExPhPlModemSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid" ::= { prtExPhPlModemEntry 2} prtExPhPlModemPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. In case of PH.1 card, only exPrt(1) is valid." ::= { prtExPhPlModemEntry 3} prtExPhPlModemStatus OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3), relay (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether a Dial Up Modem is enabled on this port. Default: disable For Vmux devices this object shows whether there is Modem Relay support." ::= { prtExPhPlModemEntry 4} prtExPhPlModemActivate OBJECT-TYPE SYNTAX INTEGER { onFirstFrame(2), always (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the Dial Up Modem is activated when the first frame is received or it is always activated. Default: onFirstFrame" ::= { prtExPhPlModemEntry 5} prtExPhPlModemMaxIdleTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Max Time allowed in Seconds without any traffic before the line is disconnected. Legal Values are: 1 sec, 2 sec .. 5 sec, 10 sec, 20 sec.. 1 min, 2 min .. 10 min, 15 min, 20 min, 25 min, 30 min. 65535 sec. means that this parameter is not applicable. Default: 1 sec." ::= { prtExPhPlModemEntry 6} prtExPhPlModemTimeBtwnCalls OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum Time in Seconds which is required after a call was disconnected. In this time no other call will be initiated from this Modem port even if there were frames transmitted to this port. This time is required for some Modems which have initializations that take a few seconds. Legal Values are: 0 sec. - 30 sec., 1-5 min. 65535 sec. means that this parameter is not applicable. Default: 0 sec" ::= { prtExPhPlModemEntry 7} prtExPhPlModemCallDelay OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Time in Seconds that the device will wait before dialing to the remote device. This feature is mostly used when there is a backup modem to the main link and the main link is down. In this case it is important to prevent the 2 devices from dialing through the backup modems to each other at the same time. It is advised to configure one side with a small call delay and the other side with a large call delay. Legal Values are: 0 - 30, 60, 120, 180, 240, 300, 600, 900, 1200, 1500, 1800 . 65535 sec. means that this parameter is not applicable. Default: 0 sec" ::= { prtExPhPlModemEntry 8} -- -- Megaplex ?000/?004 LS-2 TDM I/O family card include: -- Ls2-CCITT-X.50, Ls2-CCITT-X.58, Ls2-AT&T-SDM -- --prtExLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 1} --prtInLs2CnfgTable OBJECT IDENTIFIER ::= {prtLs2Cnfg 2} prtExLs2CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExLs2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLs2Cnfg 1} prtExLs2CnfgEntry OBJECT-TYPE SYNTAX PrtExLs2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExLs2CnfgIdx, prtExLs2SltIdx, prtExLs2PrtIdx } ::= {prtExLs2CnfgTable 1} PrtExLs2CnfgEntry ::= SEQUENCE { prtExLs2CnfgIdx Integer32, prtExLs2SltIdx INTEGER, prtExLs2PrtIdx INTEGER, prtExLs2Connect INTEGER, prtExLs2Rate INTEGER, prtExLs2ClkMode INTEGER, prtExLs2Cts INTEGER, prtExLs2Dcd INTEGER, prtExLs2EnvIdx Integer32 } prtExLs2CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExLs2CnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExLs2SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtExLs2CnfgEntry 2} prtExLs2PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port index. For the Ls2/X.58 exPrt(7)..exPrt(10) are not valid." ::= {prtExLs2CnfgEntry 3} prtExLs2Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtExLs2CnfgEntry 4} prtExLs2Rate OBJECT-TYPE SYNTAX INTEGER { r2400bps (2), r4800bps (3), r9600bps (4), r19200bps (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Port rates." ::= {prtExLs2CnfgEntry 5} prtExLs2ClkMode OBJECT-TYPE SYNTAX INTEGER { dce (1), ext-dce (2), dte (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port operation clock mode." ::= {prtExLs2CnfgEntry 6} prtExLs2Cts OBJECT-TYPE SYNTAX INTEGER { on (2), rts-min (3), rts-max (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "CTS." ::= {prtExLs2CnfgEntry 7} prtExLs2Dcd OBJECT-TYPE SYNTAX INTEGER { on (2), card-sync (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "DCD." ::= {prtExLs2CnfgEntry 8} prtExLs2EnvIdx OBJECT-TYPE SYNTAX Integer32 (0..24) MAX-ACCESS read-write STATUS current DESCRIPTION "Envelope Index. When prtInLs2EnvAssign=auto, the value is 0 (not applicable)." ::= {prtExLs2CnfgEntry 9} -- Ls2 Internal composit channel parameters -- prtInLs2CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInLs2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLs2Cnfg 2} prtInLs2CnfgEntry OBJECT-TYPE SYNTAX PrtInLs2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInLs2CnfgIdx, prtInLs2SltIdx, prtInLs2PrtIdx } ::= {prtInLs2CnfgTable 1} PrtInLs2CnfgEntry ::= SEQUENCE { prtInLs2CnfgIdx Integer32, prtInLs2SltIdx INTEGER, prtInLs2PrtIdx INTEGER, prtInLs2Connect INTEGER, prtInLs2Group Integer32, prtInLs2Member Integer32, prtInLs2LinkTo INTEGER, prtInLs2EnvAssign INTEGER } prtInLs2CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInLs2CnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtInLs2SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtInLs2CnfgEntry 2} prtInLs2PrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101), inPrt2 (102) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal port index." ::= {prtInLs2CnfgEntry 3} prtInLs2Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel." ::= {prtInLs2CnfgEntry 4} prtInLs2Group OBJECT-TYPE SYNTAX Integer32 (1..12) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the group number of the port. LS-2 internal ports with the same group number share the same Time slot of the main link" ::= {prtInLs2CnfgEntry 5} prtInLs2Member OBJECT-TYPE SYNTAX Integer32 (1..4) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the group member id of the port. This parameter is for the automatic envelope assignment algorithm." ::= {prtInLs2CnfgEntry 6} prtInLs2LinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the LS2 card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtInLs2CnfgEntry 7} prtInLs2EnvAssign OBJECT-TYPE SYNTAX INTEGER { auto (2), manual (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Envelope assignment type." ::= {prtInLs2CnfgEntry 8} -- -- Megaplex?000/?004 VC-2, VC-6, VC-2/R2, VC-Q TDM I/O family port. -- (Vc2E&m,Vc2Fxs1Plar,Vc2Fxo1,Vc2Fxs2,Vc2Fxo2,Vc2Fxs3,Vc2Fxo3) -- Vc6E&M, Vc6Fxo, Vc6Fxs, Vc6aE&M, Vc6aFxo, Vc6aFxs -- Vc2/R2(Fxs) -- VC-Q -- VC-12, VC-12/6 -- VC-8, VC-16 prtVc2CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtVc2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "- For products supporting more than one configuration, the write operation into the Table is valid only to the TmpCnfg entry. - For products that do not support configurations, the write operation into the Table will be to prtVc2CnfgIdx=1." ::= { cnfgPrtMux 5} prtVc2CnfgEntry OBJECT-TYPE SYNTAX PrtVc2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtVc2CnfgIdx, prtVc2SltIdx, prtVc2PrtIdx } ::= { prtVc2CnfgTable 1} PrtVc2CnfgEntry ::= SEQUENCE { prtVc2CnfgIdx Integer32, prtVc2SltIdx INTEGER, prtVc2PrtIdx Integer32, prtExVc2Connect INTEGER, prtExVc2TransGain Integer32, prtExVc2ReceiveGain Integer32, prtExVc2Wire INTEGER, prtExVc2CodingLaw INTEGER, prtExVc2Sig INTEGER, prtExVc2Oos INTEGER, prtExVc2LinkTo INTEGER, prtExVc2OperMode INTEGER, prtExVc2SigProfile INTEGER, prtExVc2CallEnable INTEGER, prtExVc2R2Delay INTEGER, prtExVc2CasStd INTEGER, prtExVc2EchoCanceler INTEGER, prtExVc2IfType INTEGER, prtExVc2Encoding INTEGER, prtExVc2TxBitCode OCTET STRING, prtExVc2RxBitOutput OCTET STRING, prtExVc2MeterRate INTEGER, prtExVc2IfSignaling INTEGER, prtExVc2SeizeAck INTEGER, prtExVc2EandMType INTEGER, prtExVc2RemType INTEGER, prtExVc2ConvTime INTEGER, prtExVc2SigFeedback INTEGER, prtExVc2EchoCancelerModule INTEGER, prtExVc2ReversePolarity INTEGER, prtExVc2RingerFrequency INTEGER, prtExVc2SigService INTEGER, prtExVc2CallerIdEnable INTEGER, prtExVc2CompressMethod INTEGER, prtExVc2ObMode INTEGER, prtExVc2VAD INTEGER, prtExVc2NoiseLevelForVAD INTEGER, prtExVc2WesternSigMode INTEGER, prtExVc2BusProtectionPoint INTEGER, --not used prtExVc2ImpedanceStandard INTEGER } prtVc2CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtVc2CnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtVc2SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. For Stand Alone products like WR: notApplicable (255)" ::= {prtVc2CnfgEntry 2} prtVc2PrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card. For MP-2100/2200 card ports, Web Ranger and FCD-IP Voice ports the values will be: exPrt1 (1) exPrt2 (2) exPrt3 (3) exPrt4 (4) exPrt5 (5) exPrt6 (6) exPrt7 (7) exPrt8 (8) exPrt9 (9) exPrt10 (10) exPrt11 (11) exPrt12 (12) exPrt13 (13) exPrt14 (14) exPrt15 (15) exPrt16 (16) For LA-240: The index for fixed voice ports will be - exPrt6 (6) exPrt7 (7) exPrt8 (8) exPrt9 (9) The index for voice card ports will be - Slot number * 100 + ch (for IO-1: 101..104, for IO-2: 201..204). For other products' index see their specification." ::= {prtVc2CnfgEntry 3} prtExVc2Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3), v51 (4), v52 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtVc2CnfgEntry 4} prtExVc2TransGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Transmit gain in dBm. For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8 VC-4/Omni and VC-16 cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps." ::= {prtVc2CnfgEntry 5} prtExVc2ReceiveGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Receive gain in dBm. For ports of MP-104/204, MP-2100/2200 VC-6A, VC-6AG, VC-8 VC-4/Omni and VC-16 cards, the units will be 0.1dBm because valid values can be in 0.5dBm steps." ::= {prtVc2CnfgEntry 6} prtExVc2Wire OBJECT-TYPE SYNTAX INTEGER { w2wire (1), w4wire (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "For some cards, this object is equal for all the ports in the specific card because of HW limitations. For FXO & FXS this parameter is not applicable." ::= {prtVc2CnfgEntry 7} prtExVc2CodingLaw OBJECT-TYPE SYNTAX INTEGER { aLAW (1), uLAW (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links. This object is equal for all the ports in the specific module because of HW limitations" ::= {prtVc2CnfgEntry 8} prtExVc2Sig OBJECT-TYPE SYNTAX INTEGER { noSignaling (1), robbedBitMultiFrame (2), chAssociatedE1 (3), robbedBitFrame (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the method for decoding/encoding the signaling information(on/off hook). noSignaling (1) - not using signaling (only voice). robbedBitMultiFrame(2) - is the standard method for T1 links and proprietary method for E1 links. chAssociatedE1 (3) - is valid only for E1 G.732S links. robbedBitFrame (4) - is proprietary method implimenting 7 bit for the voice and 1 bit dedicated for signaling. For some cards, this object is equal for all the ports in the specific module because of HW limitations." ::= {prtVc2CnfgEntry 9} prtExVc2Oos OBJECT-TYPE SYNTAX INTEGER { forcedIdle (1), forcedBusy (2), busyIdle (3), idleBusy (4), notApplicable (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is equal for all the ports in the specific card because of HW limitations" ::= {prtVc2CnfgEntry 10} prtExVc2LinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This attribute indicates the slot of the ML card to which the VC card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtVc2CnfgEntry 11} prtExVc2OperMode OBJECT-TYPE SYNTAX INTEGER { normal (2), unidirectRx (3), broadcast (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request." ::= {prtVc2CnfgEntry 12} prtExVc2SigProfile OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), manual (2), p1 (3), p2 (4), p3Fxo3S3 (5), reversePolarity (6), --3RP meteringPulse (7), --3MP p4 (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Signaling Profile of the port. notApplicable - for VC-2 family and when prtExVc2Sig=noSignaling(1) p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4 " ::= {prtVc2CnfgEntry 13} prtExVc2CallEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), incoming (2), outgoing (3), both (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Enabled Call direction. notApplicable - for all cards except VC-2/R2. both - incoming + outgoing." ::= {prtVc2CnfgEntry 14} prtExVc2R2Delay OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), terrestrial (2), satellite (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the R2 Delay. notApplicable - for all cards except VC-2/R2." ::= {prtVc2CnfgEntry 15} prtExVc2CasStd OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), r2Q422 (2), specialA (3), specialB (4), specialC (5), specialD (6), specialE (7), specialF (8), specialG (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the CAS (Channel Associated Signaling) Standard. notApplicable - for all cards except VC-2/R2." ::= {prtVc2CnfgEntry 16} prtExVc2EchoCanceler OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation. notApplicable - for VC-2 and VC-6 cards." ::= {prtVc2CnfgEntry 17} prtExVc2IfType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), w2Em (2), w4Em (3), fxo (4), fxs (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Interface Type." ::= {prtVc2CnfgEntry 18} prtExVc2Encoding OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), pcm (2), adpcm (3), linear (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Voice Encoding Mode. linear - is relevant only for the ports of VC-16A card." ::= {prtVc2CnfgEntry 19} prtExVc2TxBitCode OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " - - - For MP & FCD - - - This object represents 4 parameters, by 2 Octets : Tx D Bit Code-MSB nibble, Tx C Bit Code- nibble, Tx B Bit Code- nibble, Tx A Bit Code-LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = M lead 2 hex = 0010 = M lead inverse 3 hex = 0011 = Reverse Polarity 4 hex = 0100 = Metering Pulse 5 hex = 0101 = Forced 1 6 hex = 0110 = Forced 0 7-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For WR II - - - This object represents the following 4 parameters by 2 Octets: 1. On/Off hook signaling transmission mode from the FXS towards the T1/E1 (MSB nibble 1). 2. Default signaling bits that are not in use (nibble 2). 3. Ring Detection signaling transmission mode from the FXO towards the T1/E1(nibble 3). 4. M (Mouth) Signaling transmission mode from the E&M towards the T1/E1(LSB nibble 4). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook Default sig. Ring Detect. M (Mouth) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable. Not Applicable Not Applicable 1 hex = 0001 Tx A bit Values 1-3 are Tx A bit Tx A bit 2 hex = 0010 Tx A bit inverse for On/Off Hook Tx A bit inv. Tx A bit inv. 3 hex = 0011 Tx B bit A,B,A Inv,B Inv. Tx B bit Tx B bit 4 hex = 0100 Tx B bit inverse Values 4-7 are Tx B bit inv. Tx B bit inv. 5 hex = 0101 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid 6 hex = 0110 not Used-invalid A, A Inverse. not Used-invalid not Used-invalid 7 hex = 0111 not Used-invalid not Used-invalid not Used-invalid 8 hex = 1000 not Used-invalid Values 8-11 are not Used-invalid not Used-invalid 9 hex = 1001 not Used-invalid for On/Off Hook not Used-invalid not Used-invalid A hex = 1010 not used-invalid B, B Inverse. not Used-invalid not Used-invalid B hex = 1011 not used-invalid The Bits order: not Used-invalid not Used-invalid C-F hex not used-invalid ABCD not Used-invalid not Used-invalid Default value: 11 11 " ::= {prtVc2CnfgEntry 20} prtExVc2RxBitOutput OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION " - - - For MP (VC-Q card only) & FCD - - - This object represents 3 parameters by 2 Octets: Spare -MSB nibble, always=0 hex E Lead Output - nibble, Reverse Polarity Output- nibble, Metering Pulse Output -LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = Rx A bit 2 hex = 0010 = Rx A bit inverse 3 hex = 0011 = Rx B bit 4 hex = 0100 = Rx B bit inverse 5 hex = 0101 = Rx C bit 6 hex = 0110 = Rx C bit inverse 7 hex = 0111 = Rx D bit 8 hex = 1000 = Rx D bit inverse 9 hex = 1001 = none A-F hex - not used (invalid values) This object will be RO if prtExVc2SigProfile is NOT manual. - - - For MP (VC-8, VC-16, VC-16A cards) - - - This object represents 4 parameters, by 2 Octets : Tx D Bit Code-MSB nibble, Tx C Bit Code- nibble, Tx B Bit Code- nibble, Tx A Bit Code-LSB nibble. Each nibble: 0 hex = 0000 = Not Applicable 1 hex = 0001 = not used (invalid value) 2 hex = 0010 = not used (invalid value) 3 hex = 0011 = not used (invalid value) 4 hex = 0100 = not used (invalid value) 5 hex = 0101 = Forced 1 6 hex = 0110 = Forced 0 7-F hex - not used (invalid values) This object will be RO. - - - For WR II - - - This object represents the following 2 parameters in 1 Octet: 1. On/Off hook signaling receive mode from the T1/E1 into the FXS/FXO (MSB nibble 1). 2. E (Ear) Signaling receive mode from the T1/E1 into the E&M (LSB nibble 2). Each nibble: --------------------------------------------------------------------------------------- Value On/Off Hook E (Ear) --------------------------------------------------------------------------------------- 0 hex = 0000 Not Applicable Not Applicable 1 hex = 0001 Rx A bit Rx A bit 2 hex = 0010 Rx A bit inverse Rx A bit inverse 3 hex = 0011 Rx B bit Rx B bit 4 hex = 0100 Rx B bit inverse Rx B bit inverse 5-F hex not used-invalid not Used-invalid Default value: 11 " ::= {prtVc2CnfgEntry 21} prtExVc2MeterRate OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), r16Khz (2), r12Khz (3), disabled(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is applicable only for VC-6A/FXO, VC-6A/FXS, VC-8/FXO, VC-8/FXS, VC-16/FXO and VC-16/FXS. Meter Rate means rate of Call Meter in Public Phones, in KHz units. For some cards, the value must be the same for all card's ports." ::= {prtVc2CnfgEntry 22} prtExVc2IfSignaling OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), loopStart (2), groundStart (3), winkStart (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This entry is applicable only for VC-6A, VC-6AG, VC-8/FXO, VC-8/FXS, VC-16/FXO and VC-16/FXS cards. Interface Analog Signaling. Must be the same for all card's ports. loopStart - for the usual trunk/phone types. groundStart - for trunks that need Ground signaling . winkStart - for trunks that need Reverse Polarity. " ::= {prtVc2CnfgEntry 23} prtExVc2SeizeAck OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Default value for WR FXO: no(2)." ::= {prtVc2CnfgEntry 24} prtExVc2EandMType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), type1 (2), type2 (3), type3 (4), type5 (5) -- SSDC5 } MAX-ACCESS read-write STATUS current DESCRIPTION "This is the signaling type on the E&M analog side. The analog signaling includes voltage, no. of pins and other parameters." ::= {prtVc2CnfgEntry 25} prtExVc2RemType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), lb (2), pbx (3), e1 (4), t1 (5), --T1ESF t1D4 (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remote Type. Applicable for VC-6A/4LB card & for IPMUX-1E Far End Type - E1,T1(T1-ESF) or T1-D4 ." ::= {prtVc2CnfgEntry 26} prtExVc2ConvTime OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), m2 (2), m3 (3), m5 (4), unlimited (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Conversation Time in minutes. Applicable for VC-6A/4LB card." ::= {prtVc2CnfgEntry 27} prtExVc2SigFeedback OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Signaling Feedback. Applicable for VC-8/FXO and VC-16/FXO cards." ::= {prtVc2CnfgEntry 28} prtExVc2EchoCancelerModule OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), notExist (2), exist (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This parameter indicates whether Echo canceler module exists for this port." ::= {prtVc2CnfgEntry 29} prtExVc2ReversePolarity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object Enables/Disables Reverse Polarity for this port." ::= {prtVc2CnfgEntry 30} prtExVc2RingerFrequency OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), f20Hz (2), f25Hz (3), f50Hz (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object selects the Ringer Frequency (Hz) for this port." ::= {prtVc2CnfgEntry 31} prtExVc2SigService OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), normal (2), advanced (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Signaling Service. advanced - is relevant only for ports of VC-8, VC-16 FXS cards. It is used for Signaling Services of V5.1 or R2." ::= {prtVc2CnfgEntry 32} prtExVc2CallerIdEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object Enables/Disables Receiving the Caller Id number from the remote side, for this port/channel." ::= {prtVc2CnfgEntry 33} prtExVc2CompressMethod OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), g726 (2), g727 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only when prtExVc2Encoding=adpcm. It defines which method is used for Compression. g726 - for 4 bits (the standard method). g726 - for 3 bits. It is especially needed for T1 applications with signaling." ::= {prtVc2CnfgEntry 34} prtExVc2ObMode OBJECT-TYPE SYNTAX INTEGER { pointToPoint (1), omniBus (2), pointToMultiPointSrc(3), pointToMultiPointDst(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Net operation mode of the Omni-Bus card's port. pointToPoint - only 2 end-point ports talk; like any other voice card omniBus - many talk and listen. Like conference call. All can listen to all. pointToMultiPointSrc - There is one Master who can be heard by all. All can talk, but only the Master can hear all. Others can hear only the Master. This port is of the Master (Src). pointToMultiPointDst - There is one Master who can be heard by all. All can talk, but only the Master can hear all. Others can hear only the Master. This port is of a Destination (NOT Master)." ::= {prtVc2CnfgEntry 35} prtExVc2VAD OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines whether Voice Activation Detector (VAD) will be On or Off. off - will be usually selected when a Modem is connected to the port; not a phone. notApplicable - when prtExVc2DspMode=pointToPoint." ::= {prtVc2CnfgEntry 36} prtExVc2NoiseLevelForVAD OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), low (2), medium (3), high (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Level of Noise on the line, the Voice Activation Detector (VAD) will have to deal with. notApplicable - when prtExVc2VAD=off." ::= {prtVc2CnfgEntry 37} prtExVc2WesternSigMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), detector (2), generator (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Western Signaling Mode. detector - detects signal and passes it as is. generator - generates the signal. notApplicable - when Western HW is not installed." ::= {prtVc2CnfgEntry 38} prtExVc2BusProtectionPoint OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no (2), first (3), last (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines if the port is Bus Protection Point or not. notApplicable - when prtExVc2DspMode=pointToPoint. When we have a chain of devices where the edge devices ports are the Bus Protection Point, user must configure one of these ports as 'first' and the other as 'last'. It does not matter which one, it just matters that they will be different." ::= {prtVc2CnfgEntry 39} prtExVc2ImpedanceStandard OBJECT-TYPE SYNTAX INTEGER { g712 (1), q552ETSI (2), q522Italy(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Standard used for Impedance. -G.712 - 600 Ohm - used in USA and other countries. -Q552/ETSI - used in some countries in Europe -Q522/Italy - used in Italy." ::= {prtVc2CnfgEntry 40} -- -- Megaplex?000/?004 port specific config for HS(TDM) modules -- HS-2,HS-3,HS-Q, HS-Q/SC, HS-6, HS-12 -- prtHsfCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtHsfCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { cnfgPrtMux 6} prtHsfCnfgEntry OBJECT-TYPE SYNTAX PrtHsfCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtHsfCnfgIdx, prtHsfSltIdx, prtHsfPrtIdx } ::= { prtHsfCnfgTable 1} PrtHsfCnfgEntry ::= SEQUENCE { prtHsfCnfgIdx Integer32, prtHsfSltIdx INTEGER, prtHsfPrtIdx INTEGER, prtExHsfConnect INTEGER, prtExHsfRate INTEGER, prtExHsfClkMode INTEGER, prtExHsfCts INTEGER, prtExHsfFifoSize INTEGER, prtExHsfLinkTo INTEGER, prtExHsfOperMode INTEGER, prtExHsfInbandLoopback INTEGER, prtExHsfClkPolarity INTEGER, prtExHsfControlSignal INTEGER, prtExHsfBcastRingSrcPort INTEGER } prtHsfCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relate to the TmpCnfg. " ::= {prtHsfCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtHsfSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtHsfCnfgEntry 2} prtHsfPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , inPrt1 (101) , inPrt2 (102) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique external port index. Hs2 has only two ports (exPrt1,exPrt2). Hs3 has three ports (exPrt1,exPrt2,exPrt3). Hsq and hsqN has four ports. Hs6 has six external ports. Hs12 has twelve external ports. inPrt1, inPrt2 - are relevant for VID card." ::= {prtHsfCnfgEntry 3} prtExHsfConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtHsfCnfgEntry 4} prtExHsfRate OBJECT-TYPE SYNTAX INTEGER { r1x56eq56Kbps (1), r1x64eq64Kbps (2), r2x56eq112Kbps (3), r2x64eq128Kbps (4), r3x56eq168Kbps (5), r3x64eq192Kbps (6), r4x56eq224Kbps (7), r4x64eq256Kbps (8), r5x56eq280Kbps (9), r5x64eq320Kbps (10), r6x56eq336Kbps (11), r6x64eq384Kbps (12), r7x56eq392Kbps (13), r7x64eq448Kbps (14), r8x56eq448Kbps (15), r8x64eq512Kbps (16), r9x56eq504Kbps (17), r9x64eq576Kbps (18), r10x56eq560Kbps (19), r10x64eq640Kbps (20), r11x56eq616Kbps (21), r11x64eq704Kbps (22), r12x56eq672Kbps (23), r12x64eq768Kbps (24), r13x56eq728Kbps (25), r13x64eq832Kbps (26), r14x56eq784Kbps (27), r14x64eq896Kbps (28), r15x56eq840Kbps (29), r15x64eq960Kbps (30), r16x56eq896Kbps (31), r16x64eq1024Kbps(32), r17x56eq952Kbps (33), r17x64eq1088Kbps(34), r18x56eq1008Kbps(35), r18x64eq1152Kbps(36), r19x56eq1064Kbps(37), r19x64eq1216Kbps(38), r20x56eq1120Kbps(39), r20x64eq1280Kbps(40), r21x56eq1176Kbps(41), r21x64eq1344Kbps(42), r22x56eq1232Kbps(43), r22x64eq1408Kbps(44), r23x56eq1288Kbps(45), r23x64eq1472Kbps(46), r24x56eq1344Kbps(47), r24x64eq1536Kbps(48), r25x56eq1400Kbps(49), r25x64eq1600Kbps(50), r26x56eq1456Kbps(51), r26x64eq1664Kbps(52), r27x56eq1512Kbps(53), r27x64eq1728Kbps(54), r28x56eq1568Kbps(55), r28x64eq1792Kbps(56), r29x56eq1624Kbps(57), r29x64eq1856Kbps(58), r30x56eq1680Kbps(59), r30x64eq1920Kbps(60), r31x56eq1736Kbps(61), r31x64eq1984Kbps(62), r32Kbps (63) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed. " ::= {prtHsfCnfgEntry 5} prtExHsfClkMode OBJECT-TYPE SYNTAX INTEGER { dce (1), ext-dce (2), dte (3), none (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port operation clock mode." ::= { prtHsfCnfgEntry 6} prtExHsfCts OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), rts (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique CTS control line operation mode." ::= {prtHsfCnfgEntry 7} prtExHsfFifoSize OBJECT-TYPE SYNTAX INTEGER { auto (2), s16bits (3), s30bits (4), s52bits (5), s72bits (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Size in bits." ::= {prtHsfCnfgEntry 8} prtExHsfLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This attribute indicates a slot of Main Link module, that the port is linked to. This object is the same for all the ports in the specific card because of HW limitations. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtHsfCnfgEntry 9} prtExHsfOperMode OBJECT-TYPE SYNTAX INTEGER { normal (2), unidirectRx (3), broadcast (4), bidirBcastRing (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request. bidirBcastRing = Bidirectional Broadcast Ring. When this value is selected, AND RTS=On, the port opens its transmission channel." ::= {prtHsfCnfgEntry 10} prtExHsfInbandLoopback OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), ft1Enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if Inband Loopback from the Network should be enabled or disabled." ::= {prtHsfCnfgEntry 11} prtExHsfClkPolarity OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), normal (2), invert (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the clock polarity. For FCD-M this object will be applicable only for the fixed HS port (the fixed port on the device)." ::= {prtHsfCnfgEntry 12} prtExHsfControlSignal OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), local (2), endToEnd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Control Signal according to G.797 ITU-T standard. For FCD-M this object will be applicable for the fixed HS port (the fixed port on the device) and HS-Q/N channels. Local and End to End are applicable only when channel Interface type is RS-530, else it will be Not Applicable." ::= {prtHsfCnfgEntry 13} prtExHsfBcastRingSrcPort OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , none (100) , notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only when prtExHsfOperMode= bidirBcastRing. In this case, the values mean: - none - this port will be connected to ML in TSA as usual. - exPrt1.. exPrtX ; X=maximum ports of the card in focus : it means that the same TS that is assigned in TSA to this port is actually connected also to this port, for Broadcast Ring mode. Therefore, this port should NOT be connected to ML in TSA." ::= {prtHsfCnfgEntry 14} -- -- Megaplex?000/?004 Hs-4/1(HS4T1) HS-4/2(HS4E1) port configuration -- --prtExHs4CnfgTable OBJECT IDENTIFIER ::= {prtHs4Cnfg 1} --prtExHs4TsCnfgTable OBJECT IDENTIFIER ::= {prtHs4Cnfg 2} prtExHs4CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExHs4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtHs4Cnfg 1} prtExHs4CnfgEntry OBJECT-TYPE SYNTAX PrtExHs4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExHs4CnfgIdx, prtExHs4SltIdx, prtExHs4PrtIdx } ::= { prtExHs4CnfgTable 1} PrtExHs4CnfgEntry ::= SEQUENCE { prtExHs4CnfgIdx Integer32, prtExHs4SltIdx INTEGER, prtExHs4PrtIdx INTEGER, prtExHs4Connect INTEGER, prtExHs4LineType INTEGER, prtExHs4LineCode INTEGER, prtExHs4LineLen INTEGER, prtExHs4RestoreT INTEGER, prtExHs4OosSig INTEGER, prtExHs4OosCode INTEGER, prtExHs4IdleCode Integer32, prtExHs4MfClkSrcSlt INTEGER, prtExHs4MfClkSrcPrt INTEGER } prtExHs4CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExHs4CnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExHs4SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted." ::= {prtExHs4CnfgEntry 2} prtExHs4PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtExHs4CnfgEntry 3} prtExHs4Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithm. It also affects all the module considerations because the card has only one external (physical) interface." ::= {prtExHs4CnfgEntry 4} prtExHs4LineType OBJECT-TYPE SYNTAX INTEGER { esfT1 (2), --> dsx1ESF sfT1 (3), --> dsx1D4 g732nE1 (4), --> dsx1E1 g732nE1CRC (5), --> dsx1E1-CRC g732sE1 (6), --> dsx1E1-MF g732sE1CRC (7) --> dsx1E1-MF-CRC } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line type parameter for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the HS-4/1 and E1 line code parameters for the HS-4/2. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) dsx1ESF (2) dsx1D4 (3) dsx1E1 (4) dsx1E1-CRC (5) dsx1E1-MF (6) dsx1E1-MF-CRC (7)" ::= {prtExHs4CnfgEntry 5} prtExHs4LineCode OBJECT-TYPE SYNTAX INTEGER { b7T1 (1), --> dsx1JBZS b8zsT1 (2), --> dsx1B8ZS hdb3E1 (4) --> dsx1HDB3 } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line code parameter used for T1/E1 interface. The user should select only the parameters relevant to the specific card: T1 line code parameters for the MPH.1/T1 and E1 line code parameters for the MPH.1/E1. This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)" ::= {prtExHs4CnfgEntry 6} prtExHs4LineLen OBJECT-TYPE SYNTAX INTEGER { unknown (1), len0p133ft (2), len134p266ft (3), len267p399ft (4), len400p533ft (5), len534p655ft (6), fcc68 (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is the line length parameter used only for T1 interfaces. len399p533ft=len-399-533ft " ::= {prtExHs4CnfgEntry 7} prtExHs4RestoreT OBJECT-TYPE SYNTAX INTEGER { restoreT1secFast (2), restoreT10sec62411 (3), ccittE1 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Time passing from the disappearance of the loss of synchronization condition (red alarm), to the restoration of normal service." ::= {prtExHs4CnfgEntry 8} prtExHs4OosSig OBJECT-TYPE SYNTAX INTEGER { notsupported (2), forcedIdle (3), forcedBusy (4), busyIdle (5), idleBusy (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Out of Service signal type." ::= {prtExHs4CnfgEntry 9} prtExHs4OosCode OBJECT-TYPE SYNTAX INTEGER { notsupported (2), oosCode00H (3), oosCode1aH (4), oosCode54H (5), oosCode7eH (6), oosCode7fH (7), oosCode98H (8), oosCode9eH (9), oosCoded5H (10), oosCodee4H (11), oosCodeffH (12) } MAX-ACCESS read-write STATUS current DESCRIPTION "OOS Code" ::= {prtExHs4CnfgEntry 10} prtExHs4IdleCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Type value(00 - FF HEX), excluding 0H,8H,10H,12H,21H,24H, 42H,49H,84H,92H" ::= {prtExHs4CnfgEntry 11} prtExHs4MfClkSrcSlt OBJECT-TYPE SYNTAX INTEGER { local (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port Tx is multiframe synchronized with Rx multiframe of another port and the slot position of that port. This opration is required in order to bypass signaling of PCM voice channels. When its value is Local(2) there is no meaning to 'prtExHs4MfClkSrcPrt' parameter. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= {prtExHs4CnfgEntry 12} prtExHs4MfClkSrcPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), inPrt1 (101) } MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify a port position in the mux if the MultiFrame clock source is valid (YES). inPrt1 - for MTML-H/E1 cards." ::= {prtExHs4CnfgEntry 13} -- -- Hs4 Time Slot Config Table -- prtExHs4TsCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExHs4TsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtHs4Cnfg 2} prtExHs4TsEntry OBJECT-TYPE SYNTAX PrtExHs4TsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExHs4TsCnfgIdx, prtExHs4TsSltIdx, prtExHs4TsPrtIdx, prtExHs4TsIdx } ::= { prtExHs4TsCnfgTable 1} PrtExHs4TsEntry ::= SEQUENCE { prtExHs4TsCnfgIdx Integer32, prtExHs4TsSltIdx INTEGER, prtExHs4TsPrtIdx INTEGER, prtExHs4TsIdx Integer32, prtExHs4TsIConSlot INTEGER, prtExHs4TsIConPrt INTEGER, prtExHs4TsIConTs Integer32 } prtExHs4TsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExHs4TsEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExHs4TsSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtExHs4TsEntry 2} prtExHs4TsPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. Hs4/T1 and Hs4/T1 cards have only one external interface." ::= { prtExHs4TsEntry 3} prtExHs4TsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Card and 1..31 for E1 interface. In G732S-E1 lines, time slot 16 is not valid for data, it is dedicated to multiframe synchronization bits and voice signaling." ::= { prtExHs4TsEntry 4} prtExHs4TsIConSlot OBJECT-TYPE SYNTAX INTEGER { noConnect (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), split (100) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the specified time slot is connected/routed internally in the Agent and to which card it is connected. In the ?004 Unit the entries io6(10)..io16) are not valid. split - will be used when the Src TS is connected to more than one slot OR more than one port (each needing less than a whole TS)." ::= {prtExHs4TsEntry 5} prtExHs4TsIConPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) , noConnect (100) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the internally (In Mux) connected/routed port." ::= {prtExHs4TsEntry 6} prtExHs4TsIConTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique time slot position. The valid time slots are: 1..24 for T1 Module and 1..31 for E1 interface. In G732S-E1 lines time slot 16 is not valid for data, it is dedicated for multiframe synchronization bits and voice signaling." ::= { prtExHs4TsEntry 7} -- -- Megaplex?000/?004 and DXC Hs-U port configuration -- --prtExHsiCnfgTable OBJECT IDENTIFIER ::= {prtHsiCnfg 1} prtExHsiCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExHsiCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtHsiCnfg 1} prtExHsiCnfgEntry OBJECT-TYPE SYNTAX PrtExHsiCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExHsiCnfgIdx, prtExHsiSltIdx, prtExHsiPrtIdx } ::= { prtExHsiCnfgTable 1} PrtExHsiCnfgEntry ::= SEQUENCE { prtExHsiCnfgIdx Integer32, prtExHsiSltIdx INTEGER, prtExHsiPrtIdx Integer32, prtExHsiConnect INTEGER, prtExHsiRate INTEGER, prtExHsiLinkTo INTEGER, prtExHsiInterface INTEGER, prtExHsiActType INTEGER } prtExHsiCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExHsiCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExHsiSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted." ::= {prtExHsiCnfgEntry 2} prtExHsiPrtIdx OBJECT-TYPE SYNTAX Integer32 -- { -- exPrt1 (1), -- exPrt2 (2), -- exPrt3 (3), -- exPrt4 (4), -- exPrt5 (5), -- exPrt6 (6), -- exPrt7 (7), -- exPrt8 (8), -- exPrt9 (9), -- exPrt10 (10), -- exPrt11 (11), -- exPrt12 (12) -- } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card. For MP : 1..12 For DXC: 111 .. 2531. See DXC R6 spec for port index convention. For FCD-A, 'S' Interface external ports: 131, 141, 151, 161." ::= {prtExHsiCnfgEntry 3} prtExHsiConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3), v51 (4), v52 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms. v51 - this port is connected to a V5.1 interface. All rest of the values will be 'notApplicable' in this case. V5 MIB will be used instead. v52 - this port is connected to a V5.2 interface. All rest of the values will be 'notApplicable' in this case. V5 MIB will be used instead." ::= {prtExHsiCnfgEntry 4} prtExHsiRate OBJECT-TYPE SYNTAX INTEGER { r600bps (2), r1200bps (3), r2400bps (4), r4800bps (5), r9600bps (6), r19200bps (7), r38400bps (8), r48kbps (9), r56kbps (10), r64kbps (11), r128kbps (12), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed." ::= {prtExHsiCnfgEntry 5} prtExHsiLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the HS-? card is mapped. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtExHsiCnfgEntry 6} prtExHsiInterface OBJECT-TYPE SYNTAX INTEGER { lt (1), nt (2), te (3), lt1 (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "It indicates the interface type: lt = line termination nt = network termination te = terminal equipment. lt1 - for ASMi-31 connection (not ISDN) For MP: For HS-U/I only 'lt' and 'nt' are applicable. For HS-U/1 only 'lt' is applicable. For HS-S , only 'te' and 'nt' are applicable. For HS-U, this object is not applicable. For HS-U6, HS-U12, are applicable: 'lt'=lt-i,'nt'=nt-i, lt1. For DXC: For HS-U8, HS-U16, are applicable: 'lt'=LT-I,'nt'=NT-I, 'lt1'=LT-1." ::= {prtExHsiCnfgEntry 7} prtExHsiActType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), type1 (2), type2 (3), type3 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "It indicates the Activation Type. Activation Type is the Synchronization type towards the PBX. It is applicable only when prtExHsiInterface=nt. notApplicable - for cards that do not support this object, or when prtExHsiInterface is NOT nt." ::= {prtExHsiCnfgEntry 8} --prtInHsiCnfgTable OBJECT IDENTIFIER ::= {prtHsiCnfg 2} --This table is not applicable for MP-2100 HS-U card type prtInHsiCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInHsiCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry. This table is not applicable for MP-2100 HS-U card type." ::= {prtHsiCnfg 2} prtInHsiCnfgEntry OBJECT-TYPE SYNTAX PrtInHsiCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInHsiCnfgIdx, prtInHsiSltIdx, prtInHsiPrtIdx } ::= { prtInHsiCnfgTable 1} PrtInHsiCnfgEntry ::= SEQUENCE { prtInHsiCnfgIdx Integer32, prtInHsiSltIdx INTEGER, prtInHsiPrtIdx Integer32, prtInHsiConnect INTEGER, prtInHsiRate INTEGER, prtInHsiConcentratedTo Integer32 } prtInHsiCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInHsiCnfgEntry 1} prtInHsiSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique slot position where the card is inserted." ::= {prtInHsiCnfgEntry 2} prtInHsiPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card. Valid values for MP: inPrt1 (101) .. inPrt48 (148). Valid values for DXC: 11012.. 25316. See DXC R6 spec for port index convention." ::= {prtInHsiCnfgEntry 3} prtInHsiConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtInHsiCnfgEntry 4} prtInHsiRate OBJECT-TYPE SYNTAX INTEGER { r600bps (2), r1200bps (3), r2400bps (4), r4800bps (5), r9600bps (6), r19200bps (7), r38400bps (8), r48kbps (9), r56kbps (10), r64kbps (11), r128kbps (12), concentrated (13), notConnected (100), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the port speed. For HS-U/I and HS-S ports: 2 bit - up to 9600bps 4 bit - 19200bps 8 bit - 38400bps .. 64kbps. concentrated - this D channel goes to a Concentration channel, that represents many channels that this value was selected for them. The Concentrated channel is an Internal D Channel of the same card. This value is applicable only for D channels, except Concentration channel itself. --for HS-S and HS-U/I cards the Concentration channel will always be: internal-13 --for MP-2200 HS-S12, HS-S6, HS-U12, HS-U6 and DXC HS-U8 and HS-U16 cards, the Concentration channel is selected via the prtInHsiConcentratedTo object. notConnected - same as prtInHsiConnect=no." ::= {prtInHsiCnfgEntry 5} prtInHsiConcentratedTo OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The Concentration D Channel of the prtInHsiPrtIdx port. The port always belongs to the same card as prtInHsiPrtIdx port. This object is applicable only when prtInHsiRate=concentrated. Valid values: - notApplicable: 255 - for MP-2200: HS-S12, HS-U12 cards: inPrt37 (137) .. inPrt48 (148). HS-S6, HS-U6 cards: inPrt19 (119) .. inPrt24 (124). - for DXC: HS-U8 cards: 112 .. 254 HS-U16 cards: 112 .. 258. See DXC R6 spec for port index convention." ::= {prtInHsiCnfgEntry 6} -- -- Megaplex?000/?004 Hs-R and HS-U port configuration -- DXC HS-U8, HS-U16 port configuration for Interface=LT-1 -- --prtExHsrCnfgTable OBJECT IDENTIFIER ::= {prtHsrCnfg 1} prtExHsrCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExHsrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtHsrCnfg 1} prtExHsrCnfgEntry OBJECT-TYPE SYNTAX PrtExHsrCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExHsrCnfgIdx, prtExHsrSltIdx, prtExHsrPrtIdx } ::= { prtExHsrCnfgTable 1} PrtExHsrCnfgEntry ::= SEQUENCE { prtExHsrCnfgIdx Integer32, prtExHsrSltIdx INTEGER, prtExHsrPrtIdx Integer32, prtExHsrConnect INTEGER, prtExHsrProtocol INTEGER, prtExHsrRate INTEGER, prtExHsrDataBits INTEGER, prtExHsrParity INTEGER, prtExHsrStopBits INTEGER, prtExHsrCts INTEGER, prtExHsrClkMode INTEGER, prtExHsrLinkTo INTEGER, prtExHsrDcdDsr INTEGER, prtExHsrOperMode INTEGER, prtExHsrRtsDtr INTEGER, prtExHsrLlbEnable INTEGER, prtExHsrRlbEnable INTEGER, prtExHsrRateAdapt INTEGER, prtExHsrRemoteModem INTEGER , prtExHsrEncapsMode INTEGER } prtExHsrCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExHsrCnfgEntry 1} prtExHsrSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), io13 (17), io14 (18), io15 (19) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique slot position where the card is inserted." ::= {prtExHsrCnfgEntry 2} prtExHsrPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "A unique prt identifier within the card. Valid values: For MP: - For HS-R cards: exPrt1 (1) .. exPrt4 (4) - For HS-U/1 cards: inPrt1 (101) .. inPrt4 (104) - For HS-S12, HS-S6, HS-U12, HS-U6 cards: exPrt1 (1) .. exPrt12 (12). This MIB table is used only for LT-1 interface. For DXC: - For HS-U8, HS-U16 cards: 111 .. 2531 (See DXC R6 spec for port index convention). This MIB table is used only for LT-1 interface." ::= {prtExHsrCnfgEntry 3} prtExHsrConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the port should be considered in any of the mux algorithms." ::= {prtExHsrCnfgEntry 4} prtExHsrProtocol OBJECT-TYPE SYNTAX INTEGER { sync (2), async (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the protocol." ::= {prtExHsrCnfgEntry 5} prtExHsrRate OBJECT-TYPE SYNTAX INTEGER { r600bps (2), r1200bps (3), r2400bps (4), r4800bps (5), r9600bps (6), r19200bps (7), r38400bps (8), r48kbps (9), r56kbps (10), r64kbps (11), r16000bps (12), r32000bps (13), r57600bps (14), r115200bps(15), r128000bps(16), r7200bps (17), r14400bps (18), r28800bps (19), notConnected (100) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the port speed. The 16,32,48,56,64 and 128 kbps rates are applicable only for Sync protocol. The 57.6 and 115.2 kbps rates are applicable only for Async protocol. notConnected= 0 rate." ::= {prtExHsrCnfgEntry 6} prtExHsrDataBits OBJECT-TYPE SYNTAX INTEGER { d5bits (1), d6bits (2), d7bits (3), d8bits (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Data Bits. This object is applicable for Async protocol only." ::= {prtExHsrCnfgEntry 7} prtExHsrParity OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3), odd (4), even(5), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "- For HS-R card, this object indicates if the parity bit is needed or not. Therefore, the 'no' and 'yes; values are applicable. - For HS-S12, HS-U12, the parity type is selected: no, odd, even. This object is applicable for Async protocol only." ::= { prtExHsrCnfgEntry 8} prtExHsrStopBits OBJECT-TYPE SYNTAX INTEGER { stopBits1Bit (1), stopBits2Bits (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the minimum number of stop bits in the tx async frame. This object is applicable for Async protocol only." ::= { prtExHsrCnfgEntry 9} prtExHsrCts OBJECT-TYPE SYNTAX INTEGER { on (2), rts (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "CTS. This object is applicable for Async protocol only." ::= {prtExHsrCnfgEntry 10} prtExHsrClkMode OBJECT-TYPE SYNTAX INTEGER { dce (1), extDce (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Clock mode. This object is applicable for Sync protocol only." ::= { prtExHsrCnfgEntry 11} prtExHsrLinkTo OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the HS-R card is mapped. notApplicable - for HS-U/1 internal ports. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtExHsrCnfgEntry 12} prtExHsrDcdDsr OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), local (2), endToEnd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "DCD & DSR." ::= {prtExHsrCnfgEntry 13} prtExHsrOperMode OBJECT-TYPE SYNTAX INTEGER { normal (2), unidirectRx (3), broadcast (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the operation mode of the port. normal = bi-directional (Tx/Rx) unidirectRx = unidirectional Rx. broadcast = Tx upon request." ::= {prtExHsrCnfgEntry 14} prtExHsrRtsDtr OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), local (2), endToEnd (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "RTS & DTR." ::= {prtExHsrCnfgEntry 15} prtExHsrLlbEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable LLB." ::= {prtExHsrCnfgEntry 16} prtExHsrRlbEnable OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disabled (2), enabled (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable RLB." ::= {prtExHsrCnfgEntry 17} prtExHsrRateAdapt OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), proprietary (2), v110 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Rate Adaptation - takes a low rate and adapts it to 64Kbps. This object specifies the means this adaptation is done by." ::= {prtExHsrCnfgEntry 18} prtExHsrRemoteModem OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), asmi31 (2), asmi31s2 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remote modem. asmi31s2 = ASMi-31/2 " ::= {prtExHsrCnfgEntry 19} prtExHsrEncapsMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), bwOptimized (2), latencyOptimized (3), asmi31 (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Low Speed encapsulation method over PCM. When Encapsulation mode is Latency optimized, only rates up to 19.2 are supported. In this case a double number of bits occupy the Time Slot. For up to 9.6 Kbps - 4 bits are occupied. For 14.4 & 19.2 Kbps - 8 bits are occupied. When Encapsulation Mode is Bandwidth Optimized: For up to 9.6 Kbps - 2 bits are occupied. For 14.4 & 19.2 Kbps - 4 bits are occupied. For higher rates - 8 bits are occupied." ::= {prtExHsrCnfgEntry 20} -- -- Megaplex?000/?004 MBE port configuration -- prtExMbeCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExMbeCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtMbeCnfg 1} prtExMbeCnfgEntry OBJECT-TYPE SYNTAX PrtExMbeCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExMbeCnfgIdx, prtExMbeSltIdx, prtExMbePrtIdx } ::= { prtExMbeCnfgTable 1} PrtExMbeCnfgEntry ::= SEQUENCE { prtExMbeCnfgIdx Integer32, prtExMbeSltIdx INTEGER, prtExMbePrtIdx INTEGER, prtExMbeLan INTEGER } prtExMbeCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExMbeCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExMbeSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtExMbeCnfgEntry 2} prtExMbePrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card." ::= {prtExMbeCnfgEntry 3} prtExMbeLan OBJECT-TYPE SYNTAX INTEGER { remote (1), main (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the MBE port is operated as main or remote bridge." ::= {prtExMbeCnfgEntry 4} prtInMbeCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInMbeCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtMbeCnfg 2} prtInMbeCnfgEntry OBJECT-TYPE SYNTAX PrtInMbeCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInMbeCnfgIdx, prtInMbeSltIdx, prtInMbePrtIdx } ::= { prtInMbeCnfgTable 1} PrtInMbeCnfgEntry ::= SEQUENCE { prtInMbeCnfgIdx Integer32, prtInMbeSltIdx INTEGER, prtInMbePrtIdx INTEGER, prtInMbeConnect INTEGER, prtInMbeRate INTEGER, prtInMbeLinkTo INTEGER } prtInMbeCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInMbeCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtInMbeSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtInMbeCnfgEntry 2} prtInMbePrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card." ::= {prtInMbeCnfgEntry 3} prtInMbeConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtInMbeCnfgEntry 4} prtInMbeRate OBJECT-TYPE SYNTAX INTEGER { r1x64eq64Kbps (1), r2x64eq128Kbps (2), r3x64eq192Kbps (3), r4x64eq256Kbps (4), r5x64eq320Kbps (5), r6x64eq384Kbps (6), r7x64eq448Kbps (7), r8x64eq512Kbps (8), r9x64eq576Kbps (9), r10x64eq640Kbps (10), r11x64eq704Kbps (11), r12x64eq768Kbps (12), r13x64eq832Kbps (13), r14x64eq896Kbps (14), r15x64eq960Kbps (15), r16x64eq1024Kbps(16), r17x64eq1088Kbps(17), r18x64eq1152Kbps(18), r19x64eq1216Kbps(19), r20x64eq1280Kbps(20), r21x64eq1344Kbps(21), r22x64eq1408Kbps(22), r23x64eq1472Kbps(23), r24x64eq1536Kbps(24) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed." ::= {prtInMbeCnfgEntry 5} prtInMbeLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtInMbeCnfgEntry 6} -- -- Megaplex?000/?004 TRE port configuration -- prtExTreCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExTreCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtTreCnfg 1} prtExTreCnfgEntry OBJECT-TYPE SYNTAX PrtExTreCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExTreCnfgIdx, prtExTreSltIdx, prtExTrePrtIdx } ::= { prtExTreCnfgTable 1} PrtExTreCnfgEntry ::= SEQUENCE { prtExTreCnfgIdx Integer32, prtExTreSltIdx INTEGER, prtExTrePrtIdx INTEGER, prtExTreLan INTEGER, prtExTreLanRate INTEGER } prtExTreCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExTreCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExTreSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtExTreCnfgEntry 2} prtExTrePrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card." ::= {prtExTreCnfgEntry 3} prtExTreLan OBJECT-TYPE SYNTAX INTEGER { remote (1), main (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the TRE port is operated as main or remote bridge. Default=remote." ::= {prtExTreCnfgEntry 4} prtExTreLanRate OBJECT-TYPE SYNTAX INTEGER { r4M (1), r16M (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Rate of the TRE port in Mbit/sec. Default-r4M." ::= {prtExTreCnfgEntry 5} prtInTreCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInTreCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtTreCnfg 2} prtInTreCnfgEntry OBJECT-TYPE SYNTAX PrtInTreCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInTreCnfgIdx, prtInTreSltIdx, prtInTrePrtIdx } ::= { prtInTreCnfgTable 1} PrtInTreCnfgEntry ::= SEQUENCE { prtInTreCnfgIdx Integer32, prtInTreSltIdx INTEGER, prtInTrePrtIdx INTEGER, prtInTreConnect INTEGER, prtInTreRate INTEGER, prtInTreLinkTo INTEGER } prtInTreCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInTreCnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtInTreSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid." ::= {prtInTreCnfgEntry 2} prtInTrePrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique port identifier within the card." ::= {prtInTreCnfgEntry 3} prtInTreConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtInTreCnfgEntry 4} prtInTreRate OBJECT-TYPE SYNTAX INTEGER { r1x56eq56Kbps (1), r1x64eq64Kbps (2), r2x56eq112Kbps (3), r2x64eq128Kbps (4), r3x56eq168Kbps (5), r3x64eq192Kbps (6), r4x56eq224Kbps (7), r4x64eq256Kbps (8), r5x56eq280Kbps (9), r5x64eq320Kbps (10), r6x56eq336Kbps (11), r6x64eq384Kbps (12), r7x56eq392Kbps (13), r7x64eq448Kbps (14), r8x56eq448Kbps (15), r8x64eq512Kbps (16), r9x56eq504Kbps (17) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port speed." ::= {prtInTreCnfgEntry 5} prtInTreLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the MBE card is mapped. In the ?004 Unit the entries io6(10)..io16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtInTreCnfgEntry 6} -- Packet VC cards. -- This table is used for compressed voice cards with 4/8 ports. -- prtExPVc4CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPVc4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtPVc4Cnfg 1} prtExPVc4CnfgEntry OBJECT-TYPE SYNTAX PrtExPVc4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPVc4CnfgIdx, prtExPVc4SltIdx, prtExPVc4PrtIdx } ::= { prtExPVc4CnfgTable 1} PrtExPVc4CnfgEntry ::= SEQUENCE { prtExPVc4CnfgIdx Integer32, prtExPVc4SltIdx INTEGER, prtExPVc4PrtIdx INTEGER, prtExPVc4PrtType INTEGER, prtExPVc4Connect INTEGER, prtExPVc4IfType INTEGER, prtExPVc4TxGain Integer32, prtExPVc4RxGain Integer32, prtExPVc4MaxRate INTEGER, prtExPVc4Tc INTEGER, prtExPVc4Oos INTEGER, prtExPVc4EchoCanceler INTEGER, prtExPVc4VarDelay Integer32, prtExPVc4CongLevel Integer32, prtExPVc4Wire INTEGER, prtExPVc4ExtensionType INTEGER, prtExPVc4ExtensionNumber DisplayString, prtExPVc4OutPulsing INTEGER, prtExPVc4HuntGroupMb INTEGER, prtExPVc4HuntGroupIdx Integer32, prtExPVc4AutoFaxMode INTEGER, prtExPVc4FaxRate INTEGER, prtExPVc4SeizeAck INTEGER, prtExPVc4SignalingProtocol INTEGER, prtExPVc4DelayStart Integer32, prtExPVc4WinkMinDuration Integer32, prtExPVc4WinkMaxDuration Integer32, prtExPVc4GenerateTone INTEGER, prtExPVc4CodingLaw INTEGER, prtExPVc4GenerateRingBack INTEGER, prtExPVc4ChannelId Integer32, prtExPVc4PortConnection INTEGER, prtExPVc4CoderAndRate INTEGER, prtExPVc4DestinationNum DisplayString, prtExPVc4DtmfRelay INTEGER, prtExPVc4DiscOnSilence Integer32, prtExPVc4DynamicJitter INTEGER, prtExPVc4EandMType INTEGER, prtExPVc4Rate Integer32, prtExPVc4FrameSize Integer32, prtExPVc4MultiplexInterval Integer32, prtExPVc4TransportProtocol INTEGER, prtExPVc4MultiFreqRelay INTEGER, prtExPVc4MinPulseWidth Integer32, prtExPVc4MinPowerLevel Integer32, prtExPVc4SuperTandem INTEGER, prtExPVc4DestIp IpAddress, prtExPVc4DestBundle Integer32, prtExPVc4SrcIpAddress IpAddress, prtExPVc4SrcIpMask IpAddress, prtExPVc4DefaultGateway IpAddress, prtExPVc4SigPacketInterval Unsigned32 } prtExPVc4CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExPVc4CnfgEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPVc4SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted." ::= {prtExPVc4CnfgEntry 2} prtExPVc4PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), inPrt1(101), inPrt2(102), inPrt3(103), inPrt4(104), inPrt5(105), inPrt6(106), inPrt7(107), inPrt8(108) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the port number in the selected card (slot)." ::= {prtExPVc4CnfgEntry 3} prtExPVc4PrtType OBJECT-TYPE SYNTAX INTEGER { eAndM (1), fxo (2), fxs (3), internal(4), s0 (5), u (6), sQsig (7), uQsig (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the type of the selected port. In Mx 30/300 phase 4: s0 & u are for Voice over ISDN. In MX 30/300 phase 5: sQsig & uQsig are used for Voice over ISDN with Qsig option. In MX MVC4 voice cards, each pair of ports 1-2, 3-4 may have a different type: E&M, FXO, FXS. In MVC4 compressed voice cards ports 1..4 have the same interface for all ports. In MVC8 compressed voice cards each group of ports 1..4, 5..8 may have a different type: E&M, FXO, FXS." ::= {prtExPVc4CnfgEntry 4} prtExPVc4Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtExPVc4CnfgEntry 5} prtExPVc4IfType OBJECT-TYPE SYNTAX INTEGER { unknown (1), eAndM4wires (2), eAndM2wires (3), fxoGnd (4), fxoLoop (5), fxsGnd (6), fxsLoop (7), e1Framer (8), e1Slave (9), t1Framer (10), t1Slave (11) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the interface type of the port. eAndM4wires and eAndM2wires - are valid only for E&M port type eAndM4wires - means 2/4 wires fxoGnd and fxoLoop - are valid only for FXO port type fxsGnd and fxsLoop - are valid only for FXS port type e1Framer, e1Slave, t1Framer, t1Slave - are applicable for the mvc4Pbx cards only." ::= {prtExPVc4CnfgEntry 6} prtExPVc4TxGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Transmission gain in dB." ::= {prtExPVc4CnfgEntry 7} prtExPVc4RxGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Reception gain in dBm." ::= {prtExPVc4CnfgEntry 8} prtExPVc4MaxRate OBJECT-TYPE SYNTAX INTEGER { notConnected (1), r4800bps (2), r7200bps (3), r9600bps (4), notApplicatble (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Voice rate." ::= {prtExPVc4CnfgEntry 9} prtExPVc4Tc OBJECT-TYPE SYNTAX INTEGER { t1sec (1), t2sec (2), t3sec (3), t4sec (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Time interval for CIR control, in seconds. The value will be the same for all cards' ports." ::= {prtExPVc4CnfgEntry 10} prtExPVc4Oos OBJECT-TYPE SYNTAX INTEGER { notSupported (2), forcedIdle (3), forcedBusy (4), busyIdle (5), idleBusy (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Handling type, when connection is lost." ::= {prtExPVc4CnfgEntry 11} prtExPVc4EchoCanceler OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation." ::= {prtExPVc4CnfgEntry 12} prtExPVc4VarDelay OBJECT-TYPE SYNTAX Integer32 (0..300) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum variant delay of the FR network, in msec." ::= {prtExPVc4CnfgEntry 13} prtExPVc4CongLevel OBJECT-TYPE SYNTAX Integer32 (0..70) MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the level of delayed data in precents of total available dynamic memory, for which the port will start to operate as congested. The resolution of the parameter is 5%." ::= {prtExPVc4CnfgEntry 14} prtExPVc4Wire OBJECT-TYPE SYNTAX INTEGER { w2wire (1), w4wire (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the wiring of the E&M port. It is applicable only for E&M card type." ::= {prtExPVc4CnfgEntry 15} prtExPVc4ExtensionType OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), forceConnect(2), voiceSwitching(3), transparent(4), transparentPlus(5), ipForceConnect(6), permanentDial (7), autoAccept (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the type of extension relevant for this port. ipForceConnect (6) is used for automatic connection or automatic dialing when the phone is off hook (hot line). permanentDial (7) means that the call is established upon power up. The hook may be on or off. Permanent Dialing can be used when there is no signaling. autoAccept (8) means that the called party in the Permanent Dialing will accept the call from the remote side automatically upon on or off hook." ::= {prtExPVc4CnfgEntry 16} prtExPVc4ExtensionNumber OBJECT-TYPE SYNTAX DisplayString (SIZE(2)) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the extension number of this port. This field is relevant only when the extension type is voice switching and is read only if the port is member of a hunt group." ::= {prtExPVc4CnfgEntry 17} prtExPVc4OutPulsing OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no(2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This field indicates whether to outpulse the received digits. It is notApplicable(1) when the extension type is forceConnect(2)." ::= {prtExPVc4CnfgEntry 18} prtExPVc4HuntGroupMb OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no(2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if this port belongs to an hunt group." ::= {prtExPVc4CnfgEntry 19} prtExPVc4HuntGroupIdx OBJECT-TYPE SYNTAX Integer32(0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "If it belongs to an hunt group, this fields indicates the index of the relevant hunt group. 0 = notApplicable " ::= {prtExPVc4CnfgEntry 20} prtExPVc4AutoFaxMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), no(2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates if the system will switch automatically to FAX mode when detecting FAX activity. Default=Yes." ::= {prtExPVc4CnfgEntry 21} prtExPVc4FaxRate OBJECT-TYPE SYNTAX INTEGER { notConnected (1), r4800bps (2), r7200bps (3), r9600bps (4), r12000bps (5), r14400bps (6), r2400bps (7), vbdFax (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "FAX initial rate. Default=9600 bps." ::= {prtExPVc4CnfgEntry 22} prtExPVc4SeizeAck OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter shows whether the device will acknowledge a seize signal (On/Off Hook). When the value is set to yes(3) & the device receives an on/off hook signal it will transmit back an on/off hook signal. When the value is set to no(2) & the device receives an on/off hook signal it will NOT transmit back an on/off hook signal. Example: If Seize Ack Parameter = YES, when the MVC.4 receives a seize signal (Off Hook) from the PBX it will send an Off Hook to the PBX. The Seize Parameter is relevant for all the following cards: MVC-4 MVC-4/E1-Framer MVC-4/T1-DSU-Framer MVC-4/T1-CSU-Framer MVC-4/E1-SLAVE MVC-4/T1-SLAVE Default values: Analog FXS - No (value can't be changed). Analog FXO - Yes (value can't be changed). Analog E&M - No (values NO/YES). Digital E1/T1 Framer & Slave - No." ::= {prtExPVc4CnfgEntry 23} prtExPVc4SignalingProtocol OBJECT-TYPE SYNTAX INTEGER { delayStart (2), immediateStart (3), winkStart (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The signaling protocol that will be used between the PABX & the voice port. Delay Start Protocol: the line is seized by sending an Off hook signal and after a delay, if the called party is available (On hook) DTMF (Dual Tone Multi Frequency) digits are sent towards the called party. Immediate Start Protocol: the line is seized by sending an Off Hook signal and immediately DTMF digits are sent towards the called party. Wink start protocol: the line is seized by sending an Off Hook signal and then the called party sends a short Off Hook wink signal. Now the calling party starts sending DTMF digits." ::= {prtExPVc4CnfgEntry 24} prtExPVc4DelayStart OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used only for Delay Protocol. This is the time that the calling party will wait after sending an Off hook signal and before sending DTMF digits to the called party. The delay values are 100..5000 msec in intervals of 100 msec." ::= {prtExPVc4CnfgEntry 25} prtExPVc4WinkMinDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used only for Wink Protocol. Min Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec." ::= {prtExPVc4CnfgEntry 26} prtExPVc4WinkMaxDuration OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is used only for Wink Protocol. Max Duration of the Wink Signal (off hook duration from the called party). Legal values: 40..400 msec in intervals of 10 msec." ::= {prtExPVc4CnfgEntry 27} prtExPVc4GenerateTone OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates whether the device (MX or MPH) should generate dial tones for the channel. If the value is yes (3), it generates dial tones. If the value is no (2), the connected equipment will generate dial tones. For example for some ISDN sets the dial tone is generated by the phone itself while for others sets it is generated by the MX." ::= {prtExPVc4CnfgEntry 28} prtExPVc4CodingLaw OBJECT-TYPE SYNTAX INTEGER { aLAW (1), uLAW (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Method/Law for decoding/encoding the voice information. aLaw(1) is the standard Law for E1 links. uLaw(2) is the standard Law for T1 links. This object is equal for all the ports in the specific module because of HW limitations" ::= {prtExPVc4CnfgEntry 29} prtExPVc4GenerateRingBack OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines whether the Ring Back tone is generated locally or from the remote end. The default is - NO (Meaning coming from the remote end). Yes means that the Ring Back Tone is generated locally. Applicable only for Force Connect." ::= {prtExPVc4CnfgEntry 30} prtExPVc4ChannelId OBJECT-TYPE SYNTAX Integer32 (0..256) MAX-ACCESS read-write STATUS current DESCRIPTION "Channel Identifier. According to FRF11 each voice port that works as force connect should add a CH Id after the DLCI in the frame header. Default : 1 Applicable only for Force Connect. Not Applicable value will be 0." ::= {prtExPVc4CnfgEntry 31} prtExPVc4PortConnection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), line (2), trunk (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Port connection determines whether the port is connected to a PABX (Trunk) or to Telephone set (Line) . It determines whether to send certain messages to the port or not. If the type is LINE then the port generates a ring back tone , if TRUNK it doesn't (The PBX does it)." ::= {prtExPVc4CnfgEntry 32} prtExPVc4CoderAndRate OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), g7231r6300BPS (2), g7231r5300BPS (3), g729A8KBPS (4), g711aLAW (5), g711uLAW (6), g726r16KBPS (7), g726r24KBPS (8), g726r32KBPS (9), g726r40KBPS (10), g727r16KBPS (11), g727r24r16KBPS (12), g727r24KBPS (13), g727r16r32KBPS (14), g727r32r24KBPS (15), g727r32KBPS (16), g727r40r16KBPS (17), g727r40r24KBPS (18), g727r40r32KBPS (19), transparent (20), netcoder6400BPS (21), netcoder7200BPS (22), netcoder8KBPS (23), netcoder8800BPS (24), netcoder9600BPS (25), lowBitRateR2660BPS (26), amr4750BPS (27), -- Adaptive Multirate Coders of GSM amr5150BPS (28), amr5900BPS (29), amr6700BPS (30), amr7400BPS (31), amr7950BPS (32), amr10200BPS (33), amr12200BPS (34) } MAX-ACCESS read-write STATUS current DESCRIPTION "Coder and Rate for the Voice Compression. In MPH: Relevant for MVC-8 card only." ::= {prtExPVc4CnfgEntry 33} prtExPVc4DestinationNum OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The destination phone number: 0 to 22 digits. Applicable for Auto Dial - ipForceConnect(6), Permanent Dial and Auto Accept Extension Types. Default: Null String" ::= {prtExPVc4CnfgEntry 34} prtExPVc4DtmfRelay OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "When DTMF RELAY is disabled, the DTMF digits (dialed by the user) are transmitted as compressed voice and in the remote unit are decompressed. When DTMF RELAY is enabled, the DTMF digits are detected at the near side and not transmitted as voice. Instead, only an indication of what digits were dialed are transmitted and in the far end the tone is regenerated." ::= {prtExPVc4CnfgEntry 35} prtExPVc4DiscOnSilence OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "No. of silenced seconds after which the call will be disconected. A value of 0 means that there will be no disconnect when there is silence. Possible values: 0 - 900 sec." ::= {prtExPVc4CnfgEntry 36} prtExPVc4DynamicJitter OBJECT-TYPE SYNTAX INTEGER { disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The MVC8 uses two mechanisms to overcome the network delay. The first one is a static jitter buffer which holds a constant buffer of up to 300 Msec and can be controled by the JITTER parameter (prtExPVc4VarDelay). The second one is the dynamic jitter which calculates, in real time, the network delay and handles a jitter buffer dynamically. The dynamic mechanism that is implemented in MVC8, was intended to overcome network delay yet when the network bursts, the MVC8 dynamic mechanism is not able to overcome the delay. Therefore it is better not to use the dynamic jitter (DISABLE - should be the default) where bursts may occur often." ::= {prtExPVc4CnfgEntry 37} prtExPVc4EandMType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), type1 (2), type2 (3), type3 (4), ssdc5 (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is the signaling type on the E&M analog side. The analog signaling includes voltage, no. of pins and other parameters." ::= {prtExPVc4CnfgEntry 38} prtExPVc4Rate OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the Rate of the port in TS units. It is used by VF-30 card family. 0 = NA = port is not intended to be connected; therefore, no Rate." ::= {prtExPVc4CnfgEntry 39} prtExPVc4FrameSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the maximum size in Bytes of the multiplexed frame. In some cases this must be limited to avoid IP fragmentation, which makes the multiplexing useless, and can also decrease the damage in case of frame loss. Valid range: 100..1461. notApplicable=0." ::= {prtExPVc4CnfgEntry 40} prtExPVc4MultiplexInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the maximum amout of time (msec.) between multiplexed frames that are sent. For Vmux-400/420 devices: It defines the Payload Packetizing Interval. Valid values: 10-90 msec. notApplicable=0." ::= {prtExPVc4CnfgEntry 41} prtExPVc4TransportProtocol OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), ptp (2), aal2oMpls (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Transport Protocol. ptp = point to point. aal2oMpls = AAL2 over MPLS." ::= {prtExPVc4CnfgEntry 42} prtExPVc4MultiFreqRelay OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables/disables Multi Frequency Signaling Detection." ::= {prtExPVc4CnfgEntry 43} prtExPVc4MinPulseWidth OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the minimum Pulse Width in msec. Valid values: 45-100 msec. notApplicable=0." ::= {prtExPVc4CnfgEntry 44} prtExPVc4MinPowerLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the minimum Power Level in dBm. Valid values: -1..-35 dBm." ::= {prtExPVc4CnfgEntry 45} prtExPVc4SuperTandem OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Super Tandem feature provides end to end compression over multiple hops, solving the double compression problem detected in Voice compressing systems. The Super Tandem, when enabled, allows transmission of compressed voice between a few devices and eliminates the need to decompress an recompress it over each voice card and PBX, thus improving voice quality and reducing delay." ::= {prtExPVc4CnfgEntry 46} prtExPVc4DestIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the destination IP Address." ::= {prtExPVc4CnfgEntry 47} prtExPVc4DestBundle OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the destination Bundle at the far-end device." ::= {prtExPVc4CnfgEntry 48} prtExPVc4SrcIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Source IP Address." ::= {prtExPVc4CnfgEntry 49} prtExPVc4SrcIpMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Source IP Mask." ::= {prtExPVc4CnfgEntry 50} prtExPVc4DefaultGateway OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the Default Gateway for this interface." ::= {prtExPVc4CnfgEntry 51} prtExPVc4SigPacketInterval OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Defines the Signaling Packetizing Interval, which is the maximum time interval, measured in msec (milliseconds), between multiplexed signaling frames." ::= { prtExPVc4CnfgEntry 52 } -- -- Packet VC4 card -- External port Dlci table -- prtExPVc4DlciTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExPVc4DlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only at the TmpCnfg entry." ::= {prtPVc4Cnfg 2} prtExPVc4DlciEntry OBJECT-TYPE SYNTAX PrtExPVc4DlciEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExPVc4DlciCnfgIdx, prtExPVc4DlciSltIdx, prtExPVc4DlciPrtIdx} ::= { prtExPVc4DlciTable 1} PrtExPVc4DlciEntry ::= SEQUENCE { prtExPVc4DlciCnfgIdx Integer32, prtExPVc4DlciSltIdx INTEGER, prtExPVc4DlciPrtIdx INTEGER, prtExPVc4DlciValid INTEGER, prtExPVc4DlciIConSlt INTEGER, prtExPVc4DlciIConPrt INTEGER, prtExPVc4DlciIConDlci Integer32, prtExPVc4DlciTxBc INTEGER, prtExPVc4DlciTxBe INTEGER, prtExPVc4DlciRxBc INTEGER, prtExPVc4DlciRxBe INTEGER, prtExPVc4DlciPriority Integer32, prtExPVc4DlciStatus INTEGER } prtExPVc4DlciCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExPVc4DlciEntry 1} -- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid. prtExPVc4DlciSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtExPVc4DlciEntry 2} prtExPVc4DlciPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal port number. VC4 cards have four external ports." ::= { prtExPVc4DlciEntry 3} prtExPVc4DlciValid OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the attributes in this entry are valid or not. The user can add/delete pvc (dlci to dlci connection) by modifing this object" ::= { prtExPVc4DlciEntry 4} prtExPVc4DlciIConSlt OBJECT-TYPE SYNTAX INTEGER { noConnect (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique slot position In the Mux (Agent) where the dlci is routed to. In the ?004 Unit the entries io6(10)..io16) are not valid" ::= { prtExPVc4DlciEntry 5} prtExPVc4DlciIConPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , noConnect (100), inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) , inPrt7 (107) , inPrt8 (108) , inPrt9 (109) , inPrt10 (110) , inPrt11 (111) , inPrt12 (112) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port id which the dlci is routed to." ::= { prtExPVc4DlciEntry 6} prtExPVc4DlciIConDlci OBJECT-TYPE SYNTAX Integer32 (1..991) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique internal connection dlci number, the dlci is routed to." ::= { prtExPVc4DlciEntry 7} prtExPVc4DlciTxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBc9600bps (3), txBc14400bps (4), txBc19200bps (5), txBc28800bps (6), txBc32000bps (7), txBc38400bps (8), txBc48000bps (9), txBc56000bps (10), txBc57600bps (11), txBc64Kbps (12), txBc128Kbps (13), txBc192Kbps (14), txBc256Kbps (15), txBc320Kbps (16), txBc384Kbps (17), txBc448Kbps (18), txBc512Kbps (19), txBc768Kbps (20), txBc1024Kbps (21), -- --KM30 ; KM300 additional rates -- txBc16000bps (25), txBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx committed bandwidth on the user transmit line (or at the port receive line)." ::= { prtExPVc4DlciEntry 8} prtExPVc4DlciTxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), txBe9600bps (3), txBe14400bps (4), txBe19200bps (5), txBe28800bps (6), txBe32000bps (7), txBe38400bps (8), txBe48000bps (9), txBe56000bps (10), txBe57600bps (11), txBe64Kbps (12), txBe128Kbps (13), txBe192Kbps (14), txBe256Kbps (15), txBe320Kbps (16), txBe384Kbps (17), txBe448Kbps (18), txBe512Kbps (19), txBe768Kbps (20), txBe1024Kbps (21), -- --KM30 ; KM300 additional rates -- txBc16000bps (25), txBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Tx excess bandwidth on the user transmit line (or at the port receive line)." ::= { prtExPVc4DlciEntry 9} prtExPVc4DlciRxBc OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBc9600bps (3), rxBc14400bps (4), rxBc19200bps (5), rxBc28800bps (6), rxBc32000bps (7), rxBc38400bps (8), rxBc48000bps (9), rxBc56000bps (10), rxBc57600bps (11), rxBc64Kbps (12), rxBc128Kbps (13), rxBc192Kbps (14), rxBc256Kbps (15), rxBc320Kbps (16), rxBc384Kbps (17), rxBc448Kbps (18), rxBc512Kbps (19), rxBc768Kbps (20), rxBc1024Kbps (21), -- --KM30 ; KM300 additional rates -- rxBc16000bps (25), rxBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx committed bandwidth on the user receive line (or at the port transmit line)." ::= { prtExPVc4DlciEntry 10} prtExPVc4DlciRxBe OBJECT-TYPE SYNTAX INTEGER { full (1), zero (2), rxBe9600bps (3), rxBe14400bps (4), rxBe19200bps (5), rxBe28800bps (6), rxBe32000bps (7), rxBe38400bps (8), rxBe48000bps (9), rxBe56000bps (10), rxBe57600bps (11), rxBe64Kbps (12), rxBe128Kbps (13), rxBe192Kbps (14), rxBe256Kbps (15), rxBe320Kbps (16), rxBe384Kbps (17), rxBe448Kbps (18), rxBe512Kbps (19), rxBe768Kbps (20), rxBe1024Kbps (21), -- --KM30 ; KM300 additional rates -- rxBc16000bps (25), rxBc112Kbps (26) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique Rx excess bandwidth on the user receive line (or at the port transmit line)." ::= { prtExPVc4DlciEntry 11} prtExPVc4DlciPriority OBJECT-TYPE SYNTAX Integer32 (6..8) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique priority of the pvc. 6 is the lowest priority and 8 is the highest priority." ::= { prtExPVc4DlciEntry 12} prtExPVc4DlciStatus OBJECT-TYPE SYNTAX INTEGER { disconnected (1), connected (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the status of the pvc. The status is disconnected(1) when one of the sides is programmed as not connected" ::= { prtExPVc4DlciEntry 13} -- -- Megaplex ?000/?004 LS-6 TDM I/O family card include: -- Ls6, Ls6V1/E, Ls6V1/O, Ls6V1/S, Ls6V2/E, Ls6V2/O, Ls6V2/S, -- Ls6Vf/E, Ls6Vf/O, Ls6Vf/S -- --prtExLs6CnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 1} --prtExLs6VCnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 2} --prtInLs6CnfgTable OBJECT IDENTIFIER ::= {prtLs6Cnfg 3} --prtExLs6CnfgTable defines the parameters of the -- LS-6 cards family external Data ports (1-6) ; LS-12 (1-12) prtExLs6CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExLs6CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLs6Cnfg 1} prtExLs6CnfgEntry OBJECT-TYPE SYNTAX PrtExLs6CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExLs6CnfgIdx, prtExLs6SltIdx, prtExLs6PrtIdx } ::= {prtExLs6CnfgTable 1} PrtExLs6CnfgEntry ::= SEQUENCE { prtExLs6CnfgIdx Integer32, prtExLs6SltIdx INTEGER, prtExLs6PrtIdx INTEGER, prtExLs6Connect INTEGER, prtExLs6Protocol INTEGER, prtExLs6Rate INTEGER, prtExLs6ClkMode INTEGER, prtExLs6CtrlSignal INTEGER, prtExLs6DataBits INTEGER, prtExLs6Cts INTEGER, prtExLs6LinkToInternal INTEGER } prtExLs6CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExLs6CnfgEntry 1} prtExLs6SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExLs6CnfgEntry 2} prtExLs6PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) , exPrt4 (4) , exPrt5 (5) , exPrt6 (6) , exPrt7 (7) , exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port index." ::= {prtExLs6CnfgEntry 3} prtExLs6Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtExLs6CnfgEntry 4} prtExLs6Protocol OBJECT-TYPE SYNTAX INTEGER { sync (2), async (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the protocol. async - can be selected only for ports 1-2." ::= {prtExLs6CnfgEntry 5} prtExLs6Rate OBJECT-TYPE SYNTAX INTEGER { r300bps (2), r600bps (3), r1200bps (4), r2400bps (5), r4800bps (6), r7200bps (7), r8000bps (8), r9600bps (9), r14400bps (10), r16000bps (11), r19200bps (12), r24000bps (13), r28800bps (14), r32000bps (15), r38400bps (16), r48000bps (17), r56000bps (18), r57600bps (19), r64000bps (20) } MAX-ACCESS read-write STATUS current DESCRIPTION "Port rates in bps. g1 - contains the values : (2)-(6),(9),(12),(16) g2 - contains the values : (7),(10),(14),(19) g3 - contains the values : (8),(11),(13),(15),(17),(18),(20); it is not applicable when using Async protocol. Rates of pair ports (1-2, 3-4, 5-6) must be from the same group." ::= {prtExLs6CnfgEntry 6} prtExLs6ClkMode OBJECT-TYPE SYNTAX INTEGER { dce (1), extDce (2), dte1 (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates a unique port operation clock mode. It is applicable for Sync protocol only ." ::= {prtExLs6CnfgEntry 7} prtExLs6CtrlSignal OBJECT-TYPE SYNTAX INTEGER { local (2), rts (3), dtrAndRts (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Control Signal." ::= {prtExLs6CnfgEntry 8} prtExLs6DataBits OBJECT-TYPE SYNTAX INTEGER { d6bits (1), d7bits (2), d8bits (3), d9bits (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Data Bits. This object is applicable for Async protocol only." ::= {prtExLs6CnfgEntry 9} prtExLs6Cts OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), on (2), rts (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the CTS control line operation mode." ::= {prtExLs6CnfgEntry 10} prtExLs6LinkToInternal OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) , inPrt2 (102) , notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates which internal port of the card, the external port is linked to." ::= {prtExLs6CnfgEntry 11} --prtExLs6VCnfgTable defines the parameters of the -- LS-6 cards family external Voice & FAX ports (7-8) prtExLs6VCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExLs6VCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLs6Cnfg 2} prtExLs6VCnfgEntry OBJECT-TYPE SYNTAX PrtExLs6VCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExLs6VCnfgIdx, prtExLs6VSltIdx, prtExLs6VPrtIdx } ::= {prtExLs6VCnfgTable 1} PrtExLs6VCnfgEntry ::= SEQUENCE { prtExLs6VCnfgIdx Integer32, prtExLs6VSltIdx INTEGER, prtExLs6VPrtIdx INTEGER, prtExLs6VConnect INTEGER, prtExLs6VRate INTEGER, prtExLs6VEchoCanceler INTEGER, prtExLs6VIfType INTEGER, prtExLs6VTxGain Integer32, prtExLs6VRxGain Integer32, prtExLs6VOos INTEGER } prtExLs6VCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExLs6VCnfgEntry 1} prtExLs6VSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExLs6VCnfgEntry 2} prtExLs6VPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt7 (7) , exPrt8 (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtExLs6VCnfgEntry 3} prtExLs6VConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtExLs6VCnfgEntry 4} prtExLs6VRate OBJECT-TYPE SYNTAX INTEGER { r6400bps (2), r7200bps (3), r8000bps (4), r9600bps (5), r16000bps (6), r24000bps (7), r32000bps (8), r64000bps (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Rate (bps) used for FAX transmission and Voice coding." ::= {prtExLs6VCnfgEntry 5} prtExLs6VEchoCanceler OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation." ::= {prtExLs6VCnfgEntry 6} prtExLs6VIfType OBJECT-TYPE SYNTAX INTEGER { w2wire (1), w4wire (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the interface type of the port. w4wire - is applicable only for E&M port type." ::= {prtExLs6VCnfgEntry 7} prtExLs6VTxGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Transmit gain in dBm. E&M - values range: -17 .. 8 FXO - values range: -16 .. 4 FXS - values range: -13 .. 8 " ::= {prtExLs6VCnfgEntry 8} prtExLs6VRxGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Receive gain in dBm. E&M - values range: -17 .. 2 FXO - values range: -17 .. -1 FXS - values range: -17 .. 2 " ::= {prtExLs6VCnfgEntry 9} prtExLs6VOos OBJECT-TYPE SYNTAX INTEGER { forcedIdle (1), forcedBusy (2), busyIdle (3), idleBusy (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "Out of Service signaling mode." ::= {prtExLs6VCnfgEntry 10} -- Ls6 and Ls12 Internal composite channel parameters -- prtInLs6CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInLs6CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtLs6Cnfg 3} prtInLs6CnfgEntry OBJECT-TYPE SYNTAX PrtInLs6CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInLs6CnfgIdx, prtInLs6SltIdx, prtInLs6PrtIdx } ::= {prtInLs6CnfgTable 1} PrtInLs6CnfgEntry ::= SEQUENCE { prtInLs6CnfgIdx Integer32, prtInLs6SltIdx INTEGER, prtInLs6PrtIdx INTEGER, prtInLs6Connect INTEGER, prtInLs6TandemMode INTEGER, prtInLs6Rate INTEGER, prtInLs6RemoteType INTEGER, prtInLs6LinkTo INTEGER } prtInLs6CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInLs6CnfgEntry 1} prtInLs6SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtInLs6CnfgEntry 2} prtInLs6PrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101), inPrt2 (102) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique internal port index." ::= {prtInLs6CnfgEntry 3} prtInLs6Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms. It also affects all the module considerations because the module has only one Internal interface which is the composite channel." ::= {prtInLs6CnfgEntry 4} prtInLs6TandemMode OBJECT-TYPE SYNTAX INTEGER { noTandem (1), tandemMaster (2), tandemSlave (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Tandem Mode. tandemSlave - is valid only for an LS-6 card having on the (current slot-1) an LS-6 card with 'tandemMaster' mode." ::= {prtInLs6CnfgEntry 5} prtInLs6Rate OBJECT-TYPE SYNTAX INTEGER { r32Kbps (1), r56Kbps (2), r64Kpbs (3), r128Kbps (4), r256Kbps (5), r384Kbps (6), r192Kbps (7), r512Kbps (8), r768Kbps (9), r14400bps(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "Main Rate in Kbps." ::= {prtInLs6CnfgEntry 6} prtInLs6RemoteType OBJECT-TYPE SYNTAX INTEGER { ls6 (1), km2kSlave (2), km2kStandalone (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "Remote Type. notApplicable - when prtInLs6TandemMode=tandemSlave " ::= {prtInLs6CnfgEntry 7} prtInLs6LinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "It indicates the slot of the main link card to which the Ls6 card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. notApplicable - when prtInLs6TandemMode=tandemSlave. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort. " ::= {prtInLs6CnfgEntry 8} -- -- Megaplex?000/?004 VC-3 TDM I/O family port. -- (VC3/E&M,VC3/FXO,VC3/FXS) -- -- --prtExVc3CnfgTable defines the parameters of the -- VC-3 and VF-3 cards family external ports prtExVc3CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExVc3CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtVc3Cnfg 1} prtExVc3CnfgEntry OBJECT-TYPE SYNTAX PrtExVc3CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExVc3CnfgIdx, prtExVc3SltIdx, prtExVc3PrtIdx } ::= { prtExVc3CnfgTable 1} PrtExVc3CnfgEntry ::= SEQUENCE { prtExVc3CnfgIdx Integer32, prtExVc3SltIdx INTEGER, prtExVc3PrtIdx INTEGER, prtExVc3Connect INTEGER, prtExVc3TransGain Integer32, prtExVc3ReceiveGain Integer32, prtExVc3Wire INTEGER, prtExVc3Rate INTEGER, prtExVc3EchoCanceler INTEGER } prtExVc3CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExVc3CnfgEntry 1} prtExVc3SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExVc3CnfgEntry 2} prtExVc3PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) , exPrt2 (2) , exPrt3 (3) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtExVc3CnfgEntry 3} prtExVc3Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtExVc3CnfgEntry 4} prtExVc3TransGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Transmit gain in dBm." ::= {prtExVc3CnfgEntry 5} prtExVc3ReceiveGain OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Receive gain in dBm." ::= {prtExVc3CnfgEntry 6} prtExVc3Wire OBJECT-TYPE SYNTAX INTEGER { w2wire (1), w4wire (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is equal for all the ports in the specific card because of HW limitations" ::= {prtExVc3CnfgEntry 7} prtExVc3Rate OBJECT-TYPE SYNTAX INTEGER { r9600bps (1), r4800bps (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Rate in bps." ::= {prtExVc3CnfgEntry 8} prtExVc3EchoCanceler OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation. The value will be the same for all the card's external ports." ::= {prtExVc3CnfgEntry 9} --prtInVc3CnfgTable defines the parameters of the -- VC-3 or VF-3 cards family internal ports prtInVc3CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtInVc3CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtVc3Cnfg 2} prtInVc3CnfgEntry OBJECT-TYPE SYNTAX PrtInVc3CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtInVc3CnfgIdx, prtInVc3SltIdx, prtInVc3PrtIdx } ::= { prtInVc3CnfgTable 1} PrtInVc3CnfgEntry ::= SEQUENCE { prtInVc3CnfgIdx Integer32, prtInVc3SltIdx INTEGER, prtInVc3PrtIdx INTEGER, prtInVc3Connect INTEGER, prtInVc3Rate INTEGER, prtInVc3Oos INTEGER, prtInVc3LinkTo INTEGER } prtInVc3CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtInVc3CnfgEntry 1} prtInVc3SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtInVc3CnfgEntry 2} prtInVc3PrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtInVc3CnfgEntry 3} prtInVc3Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be considered in any of the mux algorithms." ::= {prtInVc3CnfgEntry 4} prtInVc3Rate OBJECT-TYPE SYNTAX INTEGER { r32000bps (1), r16000bps (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Rate in bps." ::= {prtInVc3CnfgEntry 5} prtInVc3Oos OBJECT-TYPE SYNTAX INTEGER { forcedIdle (1), forcedBusy (2), busyIdle (3), idleBusy (4) } MAX-ACCESS read-write STATUS current DESCRIPTION " This object is equal for all the ports in the specific card because of HW limitations" ::= {prtInVc3CnfgEntry 6} prtInVc3LinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This attribute indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtInVc3CnfgEntry 7} -- -- Megaplex?000/?004 VC-3 TDM I/O family port. -- (VC-PBX, VC-PBX/T1,VC-PBX/E1) -- -- --prtExVcPbxCnfgTable defines the parameters of the -- VC-PBX or VF-PBX cards family external ports prtExVcPbxCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExVcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtVcPbxCnfg 1} prtExVcPbxCnfgEntry OBJECT-TYPE SYNTAX PrtExVcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExVcPbxCnfgIdx, prtExVcPbxSltIdx, prtExVcPbxPrtIdx } ::= { prtExVcPbxCnfgTable 1} PrtExVcPbxCnfgEntry ::= SEQUENCE { prtExVcPbxCnfgIdx Integer32, prtExVcPbxSltIdx INTEGER, prtExVcPbxPrtIdx INTEGER, prtExVcPbxConnect INTEGER, prtExVcPbxGroup INTEGER, prtExVcPbxTransparent INTEGER, prtExVcPbxTransSignalTs Integer32, prtExVcPbxFrame INTEGER, prtExVcPbxRestoreTime INTEGER, prtExVcPbxLineCode INTEGER, prtExVcPbxLineLength INTEGER, prtExVcPbxLinkTo INTEGER, prtExVcPbxSignalOper INTEGER, prtExVcPbxIdleCode INTEGER } prtExVcPbxCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtExVcPbxCnfgEntry 1} prtExVcPbxSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExVcPbxCnfgEntry 2} prtExVcPbxPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtExVcPbxCnfgEntry 3} prtExVcPbxConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the port should be considered in any of the mux algorithms." ::= {prtExVcPbxCnfgEntry 4} prtExVcPbxGroup OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "The group object links together several VC-PBX cards, concerning compression of the same input T1/E1 link time-slots. When ports of different slots have the same group, they are linked. When ports have a different group, they are not linked. For VC-PBX/T1 and E1 cards, this object is - their own IO Slot. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExVcPbxCnfgEntry 5} prtExVcPbxTransparent OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the Transparent transfer of Time-Slots is required or not. Time-Slots transferred by Transparent, will not be compressed. no - applicable only for VC-PBX/T1 and VC-PBX/E1 cards yes - applicable only for VC-PBX/T1 and VC-PBX/E1 cards notApplicable - only for VC-PBX cards." ::= {prtExVcPbxCnfgEntry 6} prtExVcPbxTransSignalTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object specifies the ML Time-Slot dedicated to the signaling of the PABX Transparent TSs. None = 255. When prtExVcPbxTransparent=no this object's value=None (255) When prtExVcPbxTransparent=notApplicable, this object's value=None (255). When prtExVcPbxTransparent=yes: - for VC-PBX/T1 ports, this object's valid values are 1..16 or None (255). - for VC-PBX/E1 ports, this object's value will be 16 or None (255)." ::= {prtExVcPbxCnfgEntry 7} prtExVcPbxFrame OBJECT-TYPE SYNTAX INTEGER { esfT1 (2), --> dsx1ESF sfT1 (3), --> dsx1D4 g732nE1 (4), --> dsx1E1 g732nE1CRC (5), --> dsx1E1-CRC g732sE1 (6), --> dsx1E1-MF g732sE1CRC (7), --> dsx1E1-MF-CRC notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the frame parameter for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 values for the VC-PBX/T1 card. E1 values for the VC-PBX/E1 card. notApplicable - for the VC-PBX card. This parameter has the same values as dsx1LineType in T1/E1 MIB (RFC-1406). The parameters in dsx1LineType are: other (1) esfT1 dsx1ESF (2) sfT1 dsx1D4 (3) g732nE1 dsx1E1 (4) g732nE1CRC dsx1E1-CRC (5) g732sE1 dsx1E1-MF (6) g732sE1CRC dsx1E1-MF-CRC (7) " ::= {prtExVcPbxCnfgEntry 8} prtExVcPbxRestoreTime OBJECT-TYPE SYNTAX INTEGER { restoreT1secFast (2), restoreT10sec62411 (3), ccittE1 (4), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "The time passing from the disappearance of the loss of synchronization condition (red alarm) to the restoration of normal service. The options 1secFast(2) and 10sec62411(3) for E1 interfaces are proprietary implementation of the T1 standard to the E1 interface. ccittE1 - is applicable only for VC-PBX/E1 card notApplicable - is applicable for VC-PBX card" ::= {prtExVcPbxCnfgEntry 9} prtExVcPbxLineCode OBJECT-TYPE SYNTAX INTEGER { b7zsT1 (1), --> dsx1JBZS b8zsT1 (2), --> dsx1B8ZS transT1(3), --> dsx1AMI hdb3E1 (4), --> dsx1HDB3 notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the line code parameter used for T1/E1 interface. The user should select only the parameters which are relevant to the specific card: T1 line code parameters for VC-PBX/T1 E1 line code parameters for VC-PBX/E1 notApplicable - for VC-PBX This parameter has the same values as dsx1LineCoding in T1/E1 MIB (RFC-1406). The parameters in dsx1LineCoding are: dsx1JBZS (1) dsx1B8ZS (2) dsx1HDB3 (3) dsx1ZBTSI (4) dsx1AMI (5) other (6)" ::= {prtExVcPbxCnfgEntry 10} prtExVcPbxLineLength OBJECT-TYPE SYNTAX INTEGER { unknown (1), len0p133ft (2), len134p266ft (3), len267p399ft (4), len400p533ft (5), len534p655ft (6), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object is the line length parameter. It is applicable only for the VC-PBX/T1 card. notApplicable - for the VC-PBX and VC-PBX/E1 card. lenXXXpXXXft = len-XXX-XXXft." ::= {prtExVcPbxCnfgEntry 11} prtExVcPbxLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object indicates the slot of the ML card to which the VC-PBX/T1, VC-PBX/E1 card Transparent TSs are mapped. notApplicable - for VC-PBX card AND for VC-PBX/T1, VC-PBX/E1 cards, when prtExVcPbxTransparent=no . In the ?004 Unit the entries io6(10)..io12(16) are not valid. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtExVcPbxCnfgEntry 12} prtExVcPbxSignalOper OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), normal (2), bEqA (3), inverseA (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Signaling Operation of the VC-PBX/T1, VC-PBX/E1 external port. notApplicable - for VC-PBX card normal - all 4 signaling bits are transferred. bEqA - copy the A bit into the B bit. Applicable only for VC-PBX/T1." ::= {prtExVcPbxCnfgEntry 13} prtExVcPbxIdleCode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), hff (2), he4 (3), hd5 (4), h9e (5), h98 (6), h7f (7), h7e (8), h54 (9), h1a (10) } MAX-ACCESS read-write STATUS current DESCRIPTION "Determines the code for transmission in empty time slots. notApplicable - for VC-PBX card ." ::= {prtExVcPbxCnfgEntry 14} --prtIn1p6VcPbxCnfgTable defines the parameters of the -- VC-PBX or VF-PBX cards family internal ports 1-6 prtIn1p6VcPbxCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIn1p6VcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtVcPbxCnfg 2} prtIn1p6VcPbxCnfgEntry OBJECT-TYPE SYNTAX PrtIn1p6VcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtIn1p6VcPbxCnfgIdx, prtIn1p6VcPbxSltIdx, prtIn1p6VcPbxPrtIdx } ::= { prtIn1p6VcPbxCnfgTable 1} PrtIn1p6VcPbxCnfgEntry ::= SEQUENCE { prtIn1p6VcPbxCnfgIdx Integer32, prtIn1p6VcPbxSltIdx INTEGER, prtIn1p6VcPbxPrtIdx INTEGER, prtIn1p6VcPbxConnect INTEGER, prtIn1p6VcPbxRate INTEGER, prtIn1p6VcPbxEchoCanceler INTEGER, prtIn1p6VcPbxPabxTs Integer32 } prtIn1p6VcPbxCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtIn1p6VcPbxCnfgEntry 1} prtIn1p6VcPbxSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtIn1p6VcPbxCnfgEntry 2} prtIn1p6VcPbxPrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt1 (101) , inPrt2 (102) , inPrt3 (103) , inPrt4 (104) , inPrt5 (105) , inPrt6 (106) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtIn1p6VcPbxCnfgEntry 3} prtIn1p6VcPbxConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the port should be considered in any of the mux algorithms." ::= {prtIn1p6VcPbxCnfgEntry 4} prtIn1p6VcPbxRate OBJECT-TYPE SYNTAX INTEGER { r4800bps (1), r6400bps (2), r7200bps (3), r8000bps (4), r9600bps (5), r12800bps (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the port Rate. For Normal mode (prtIn7p8VcPbxMode=normal), only part of the values are valid (constant rate). For Server mode (prtIn7p8VcPbxMode=server), all values are applicable (user can select the desired compression rate). " ::= {prtIn1p6VcPbxCnfgEntry 5} prtIn1p6VcPbxEchoCanceler OBJECT-TYPE SYNTAX INTEGER { off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation." ::= {prtIn1p6VcPbxCnfgEntry 6} prtIn1p6VcPbxPabxTs OBJECT-TYPE SYNTAX Integer32 (1..31) MAX-ACCESS read-only STATUS current DESCRIPTION "This object defines the PABX Time-Slot assigned to this internal port. For a T1 link, the valid values are: 1 .. 24. For an E1 link, the valid values are: 1 .. 31. This object is NOT applicable when prtIn1p6VcPbxConnect=no. This object is applicable for all cards of VC-PBX family. Default=the internal port index (1..6)." ::= {prtIn1p6VcPbxCnfgEntry 7} --prtIn7p8VcPbxCnfgTable defines the parameters of the -- VC-PBX or VF-PBX cards family internal ports 7-8 prtIn7p8VcPbxCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIn7p8VcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= { prtVcPbxCnfg 3} prtIn7p8VcPbxCnfgEntry OBJECT-TYPE SYNTAX PrtIn7p8VcPbxCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtIn7p8VcPbxCnfgIdx, prtIn7p8VcPbxSltIdx, prtIn7p8VcPbxPrtIdx } ::= { prtIn7p8VcPbxCnfgTable 1} PrtIn7p8VcPbxCnfgEntry ::= SEQUENCE { prtIn7p8VcPbxCnfgIdx Integer32, prtIn7p8VcPbxSltIdx INTEGER, prtIn7p8VcPbxPrtIdx INTEGER, prtIn7p8VcPbxConnect INTEGER, prtIn7p8VcPbxMode INTEGER, prtIn7p8VcPbxRate INTEGER, prtIn7p8VcPbxSignalMode INTEGER, prtIn7p8VcPbxOos INTEGER, prtIn7p8VcPbxLinkTo INTEGER } prtIn7p8VcPbxCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg" ::= {prtIn7p8VcPbxCnfgEntry 1} prtIn7p8VcPbxSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtIn7p8VcPbxCnfgEntry 2} prtIn7p8VcPbxPrtIdx OBJECT-TYPE SYNTAX INTEGER { inPrt7 (107) , inPrt8 (108) } MAX-ACCESS read-only STATUS current DESCRIPTION "A unique identifier of the port, within the card." ::= {prtIn7p8VcPbxCnfgEntry 3} prtIn7p8VcPbxConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the port should be considered in any of the mux algorithms." ::= {prtIn7p8VcPbxCnfgEntry 4} prtIn7p8VcPbxMode OBJECT-TYPE SYNTAX INTEGER { normal (1), server (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the working mode of the port: - normal - the compressed voice will be sent to an MTML card inside the Mux. - server - the compressed voice will be sent to the Digital Voice connector, as a service to an outside user." ::= {prtIn7p8VcPbxCnfgEntry 5} prtIn7p8VcPbxRate OBJECT-TYPE SYNTAX INTEGER { r32Kbps (1), r16Kbps (2), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the port Main Rate. For Server mode (prtIn7p8VcPbxMode=server), the value will be notApplicable. " ::= {prtIn7p8VcPbxCnfgEntry 6} prtIn7p8VcPbxSignalMode OBJECT-TYPE SYNTAX INTEGER { none (1), aBit (2), abcBit (3), abcdBit (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Signal Mode. For Server mode (prtIn7p8VcPbxMode=server), the only valid values are: - none - aBit " ::= {prtIn7p8VcPbxCnfgEntry 7} prtIn7p8VcPbxOos OBJECT-TYPE SYNTAX INTEGER { forcedIdle (1), forcedBusy (2) } MAX-ACCESS read-write STATUS current DESCRIPTION " Out of service Signaling mode." ::= {prtIn7p8VcPbxCnfgEntry 8} prtIn7p8VcPbxLinkTo OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "This object indicates the slot of the ML card to which the VC card is mapped. In the ?004 Unit the entries io6(10)..io12(16) are not valid. For Server mode (prtIn7p8VcPbxMode=server), this object is not applicable. Both ports, 7 and 8 should be linked to the same Slot. STATUS deprecated - this object is replaced by prtGenCnfgLinkToSlot and prtGenCnfgLinkToPort." ::= {prtIn7p8VcPbxCnfgEntry 9} --prtExVcPbxTsTable defines PABX Time Slots assignment of the -- VC-PBX E1/T1 cards, VF-PBX cards , VF-24/30/48/60 T1/E1 cards -- and VFS cards prtExVcPbxTsTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtExVcPbxTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the table objects is valid only to the TmpCnfg entry." ::= { prtVcPbxCnfg 4} prtExVcPbxTsEntry OBJECT-TYPE SYNTAX PrtExVcPbxTsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtExVcPbxTsCnfgIdx, prtExVcPbxTsSltIdx, prtExVcPbxTsPrtIdx, prtExVcPbxTsIdx } ::= { prtExVcPbxTsTable 1} PrtExVcPbxTsEntry ::= SEQUENCE { prtExVcPbxTsCnfgIdx Integer32, prtExVcPbxTsSltIdx INTEGER, prtExVcPbxTsPrtIdx INTEGER, prtExVcPbxTsIdx Integer32, prtExVcPbxTsMode INTEGER, prtExVcPbxTsIConSlot INTEGER, prtExVcPbxTsIConPrt INTEGER, prtExVcPbxTsIConTs Integer32, prtExVcPbxTsRemPrt INTEGER, prtExVcPbxTsRemTs Integer32, prtExVcPbxTsRemConnID Unsigned32, prtExVcPbxTsSourceSlot INTEGER, prtExVcPbxTsSourcePrt Unsigned32 } prtExVcPbxTsCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtExVcPbxTsEntry 1} prtExVcPbxTsSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid" ::= { prtExVcPbxTsEntry 2} prtExVcPbxTsPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), inPrt9 (109), inPrt10 (110) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. VCPBX/E1, VCPBX/T1, VFPBX/E1, VFPBX/T1, VF-24/T1 and VF-30 cards have only one external interface. VF-48/T1 and VF-60/E1 cards have two external interfaces. VFS cards have also internal ports." ::= { prtExVcPbxTsEntry 3} prtExVcPbxTsIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique PABX time slot position. The valid time slots are 1..24 for T1 cards and 1..31 for E1 cards." ::= { prtExVcPbxTsEntry 4} prtExVcPbxTsMode OBJECT-TYPE SYNTAX INTEGER { unused (1), compressed (2), -- =compressedVoice transparent (3), compressedCcs(4), mng (5), ccs1 (11), ccs2 (12), ccs3 (13), ccs4 (14), ccs5 (15), ccs6 (16), ccs7 (17), ccs8 (18), ss7n1 (41), ss7n2 (42), ss7n3 (43), ss7n4 (44), ss7n5 (45), ss7n6 (46), ss7n7 (47), ss7n8 (48) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the usage, process and way of the specific PABX TS towards its destination: unused - the TS is not used (no processing, no destination). compressed - the TS is used, sent for compression to an internal port (for VF-PBX cards: 1..6 for of either the same card or a VF-PBX card of the same group). For VF-24/30/48/60 - 'compressed' represents 'compressed Voice' (to differentiate it from 'compressedCcs'). In this case, the TS is compressed by an internal port (1..8). transparent - the TS is used; no processing. It is sent directly for Bypass to a ML card the VF port/TS is linked to. compressedCcs - supported only by VF-24/30/48/60 cards. The TS is used; sent for compression to the CPU. mng - the TS is used for Management (this option is used when the external port is connected to another product that has to be managed via this dedicated TS. ccs1..ccs8 - supported only by VF-24/30/48/60 cards. Compressed TS that comes from a bundle of V5.1 or V5.2 PBX. ss7n1..ss7n8 - supported only by VF-24/30/48/60 cards. Compressed TS that comes from a bundle of V5.1 or V5.2 PBX. ss7n1 can work versus Vmux having prtExPh1MlTsType=ss7(6)." ::= { prtExVcPbxTsEntry 5} prtExVcPbxTsIConSlot OBJECT-TYPE SYNTAX INTEGER { noConnect (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "For VF-PBX cards, the io1..io12 values are applicable only when prtExVcPbxTsMode=compressed. Otherwise, its value should be noConnect. For VF-24/30/48/60 cards: - when prtExVcPbxTsMode=transparent or voiceTransparent, the io1..io12 values are applicable, indicating the ML Slot this TS is connected to. - when prtExVcPbxTsMode=compressed or compressedCcs, the value will be the same as prtExVcPbxTsSltIdx, since the compression is done within the same card. - for rest of the prtExVcPbxTsMode values, the value will be: noConnect. This object indicates whether the specified compressed/transparent time slot is connected/routed internally in the Agent and to which card it is connected. For VF-PBX card, the valid selectable slots are either the current one, (prtExVcPbxTsSltIdx), or a slot containing a VF-PBX card. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExVcPbxTsEntry 6} prtExVcPbxTsIConPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), exPrt5 (5), exPrt6 (6), exPrt7 (7), exPrt8 (8), noConnect (100), inPrt1 (101), inPrt2 (102), inPrt3 (103), inPrt4 (104), inPrt5 (105), inPrt6 (106), inPrt7 (107), inPrt8 (108) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the port to which this TS is connected. For VF-PBX cards, only inPrt1..inPrt6 ports are valid. For VF-24/30/48/60 cards: - for prtExVcPbxTsMode=transparent or voiceTransparent, the valid ports are ML ports (exPrt1.. exPrt8, inPrt1.. inPrt8) - for prtExVcPbxTsMode=compressed or compressedCcs, the valid ports are internal ports of the same card (inPrt1..inPrt8) noConnect - when prtExVcPbxTsIConSlot=noConnect." ::= {prtExVcPbxTsEntry 7} prtExVcPbxTsIConTs OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the ML TS to which this TS is connected. This object is not applicable for VF-PBX cards. For VF-24/30/48/60 cards it is applicable only when prtExVcPbxTsMode=transparent or voiceTransparent. The valid time slots are 1..24 for ML T1 cards and 1..31 for ML E1 cards. notApplicable - 255. " ::= { prtExVcPbxTsEntry 8} prtExVcPbxTsRemPrt OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), noConnect (100) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the end-point port on the Remote unit. VF-24/T1 and VF-30/E1 cards have one external interface. VF-48/T1 and VF-60/E1 cards have two external interfaces. noConnect - when prtExVcPbxTsMode=unused, transparent, voiceTransparent or mng." ::= { prtExVcPbxTsEntry 9} prtExVcPbxTsRemTs OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the end-point TS on the Remote unit. The valid time slots are 1..24 for T1 ports and 1..31 for E1 ports. notApplicable - 255." ::= { prtExVcPbxTsEntry 10} prtExVcPbxTsRemConnID OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Connection ID with the Remote unit. notApplicable = 0." ::= { prtExVcPbxTsEntry 11} prtExVcPbxTsSourceSlot OBJECT-TYPE SYNTAX INTEGER { noConnect (2), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-write STATUS current DESCRIPTION "For VFS cards. These cards offer Compresed Voice Services for Analog Voice ports of the MP. This object indicates the Source Slot of the Analog Voice port we want to compress. io1..io12 values are applicable only when prtExVcPbxTsMode=compressed(voice). Otherwise, its value should be noConnect. In the ?004 Unit the entries io6(10)..io12(16) are not valid." ::= {prtExVcPbxTsEntry 12} prtExVcPbxTsSourcePrt OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "For VFS cards. These cards offer Compresed Voice Services for Analog Voice ports of the MP. This object indicates the Source Port within the Slot of the Analog Voice Card, we want to compress. exPrt1 - exPrt16 = 1 - 16 noConnect=100 - when prtExVcPbxTsCvServiceSlot=noConnect." ::= {prtExVcPbxTsEntry 13} -- The following tables contains information specific to -- the isdn access modules prtIsdnCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIsdnCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the table objects is valid only to the TmpCnfg entry." ::= { prtIsdnCnfg 1} prtIsdnCnfgEntry OBJECT-TYPE SYNTAX PrtIsdnCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtIsdnCnfgIdx, prtIsdnSltIdx, prtIsdnPrtIdx} ::= { prtIsdnCnfgTable 1} PrtIsdnCnfgEntry ::= SEQUENCE { prtIsdnCnfgIdx Integer32, prtIsdnSltIdx INTEGER, prtIsdnPrtIdx Integer32, prtIsdnConnect INTEGER, prtIsdnSignalingProtocol INTEGER, prtIsdnBasicRateLineTopology INTEGER, prtIsdnMode INTEGER, prtIsdnFilter INTEGER, prtIsdnSimultaneousCall INTEGER, prtIsdnNumOfAbstractTerm Integer32, prtIsdnSwitchMode INTEGER, prtIsdnAbSide INTEGER, prtIsdnQsigRole INTEGER, prtIsdnInterface INTEGER, prtIsdnCallMode INTEGER, prtIsdnCallBackTimeout Integer32 } prtIsdnCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtIsdnCnfgEntry 1} prtIsdnSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10(14), io11(15), io12(16), kmxMlA (103), kmxMlB (104), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In the ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'" ::= { prtIsdnCnfgEntry 2} prtIsdnPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch" ::= { prtIsdnCnfgEntry 3} prtIsdnConnect OBJECT-TYPE SYNTAX INTEGER { no(2), yes(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates if the port is connected." ::= { prtIsdnCnfgEntry 4 } prtIsdnSignalingProtocol OBJECT-TYPE SYNTAX INTEGER { other(1), etsi(3), ess4(5), ess5(6), dms100(7), ni1(9), ni2(10), ins64(17), ins1500(18), qsig(21), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute fixes which signaling protocol is used at this port (D-Channel). It is equivalent to isdnSignalingProtocol in the isdn MIB." DEFVAL { etsi } ::= { prtIsdnCnfgEntry 5 } prtIsdnBasicRateLineTopology OBJECT-TYPE SYNTAX INTEGER { pointToPoint(1), pointToMultipoint(2), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute is relevant for ISDN BRI only. It is equivalent to isdnBasicRateLineTopology in the isdn MIB." ::= { prtIsdnCnfgEntry 6 } prtIsdnMode OBJECT-TYPE SYNTAX INTEGER { dialup(1), leased(2), syncLeased(3), notApplicable(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute allows the user to configure the port as leased(2) in case of connection to a TDM network." ::= { prtIsdnCnfgEntry 7} prtIsdnFilter OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), answerAll(2), rejectAll(3), selective(4), callBack (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute allows the user to configure the port: answerAll(2): accept all incoming calls, rejectAll(3): reject all incoming calls, selective(4): accept or reject according directory table. callBack (5): In this mode the ISDN Ch will reject incoming calls and will initiate call back to the rejected phone number." ::= { prtIsdnCnfgEntry 8} prtIsdnSimultaneousCall OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), accept(2), reject(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "In case of simultaneous call (local,remote and remote,local): accept(2): accept the incoming call, reject(3): reject the incoming call." ::= { prtIsdnCnfgEntry 9} prtIsdnNumOfAbstractTerm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "An object for KM2100/4 agents. 255=Not Applicable When ISDN Standard = ETSI or NTT (European) the value should be 255 (NotApplicable) else If ML speed is 64Kbps value should be 1. If ML speed is 128Kbps value can be either 1 or 2 (user selection)." ::= { prtIsdnCnfgEntry 10} prtIsdnSwitchMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), auto (2), manual (3), connect(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "For KM2100. auto - The call is initiated automatically by one of the IO cards connected to KML.10(ISDN card) having ISDN Switch Mode. manual - The call is initiated by the user manually, for KML.10 having ISDN Switch Mode (via mdlSCmd). connect- The call is initiated 'immediately', for KML.10 having ISDN Switch Mode. 'immediately'- means: immediately after power-up (when product performed Reset) OR, since this value appears in the active configuration. In this case, the call can be disconnected only by power-off of the product or by changing this object to another value (or actual Remove of the KML.10 relevant card). notApplicable - For other card types." ::= { prtIsdnCnfgEntry 11} prtIsdnAbSide OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), aSide (2), bSide (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the QSIG side in layer 3. This definition is from the QSIG Standard." ::= { prtIsdnCnfgEntry 12} prtIsdnQsigRole OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), slave (2), master (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter indicates the QSIG side in layer 1 & 2." ::= { prtIsdnCnfgEntry 13} prtIsdnInterface OBJECT-TYPE SYNTAX INTEGER { lt (1), nt (2), te (3), notApplicable (255) } MAX-ACCESS read-write STATUS current DESCRIPTION "It indicates the interface type: lt = line termination nt = network termination te = terminal equipment." ::= { prtIsdnCnfgEntry 14} prtIsdnCallMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), initiate (2), listen (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the acceptance of incoming calls. Initiate - Callout Listen - Callin. " ::= { prtIsdnCnfgEntry 15} prtIsdnCallBackTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object is applicable only if 'prtIsdnFilter' is 'CallBack' and determines how long to wait from receiving the incoming call until initiating the call back call. The vaules range should be '1..20 sec' and the default 10 sec." ::= { prtIsdnCnfgEntry 16} prtIsdnEndpointTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIsdnEndpointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the table objects is valid only to the TmpCnfg entry." ::= { prtIsdnCnfg 2} prtIsdnEndpointEntry OBJECT-TYPE SYNTAX PrtIsdnEndpointEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtIsdnEndpointCnfgIdx, prtIsdnEndpointSltIdx, prtIsdnEndpointPrtIdx, prtIsdnEndpointIdx } ::= { prtIsdnEndpointTable 1} PrtIsdnEndpointEntry ::= SEQUENCE { prtIsdnEndpointCnfgIdx Integer32, prtIsdnEndpointSltIdx INTEGER, prtIsdnEndpointPrtIdx Integer32, prtIsdnEndpointIdx INTEGER, prtIsdnEndpointTeiType INTEGER, prtIsdnEndpointTeiValue Integer32, prtIsdnEndpointSpid DisplayString, prtIsdnEndpointBearerCh INTEGER, prtIsdnEndpointRowStatus RowStatus } prtIsdnEndpointCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtIsdnEndpointEntry 1} prtIsdnEndpointSltIdx OBJECT-TYPE SYNTAX INTEGER { io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA (103), kmxMlB (104), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'" ::= { prtIsdnEndpointEntry 2} prtIsdnEndpointPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. For MAXcess the values will be: exPrt1(1), exPrt2(2), exPrt3(3), exPrt4(4), For KM-2100 the port index is calculated as follows: 100*Slot+Ch" ::= { prtIsdnEndpointEntry 3} prtIsdnEndpointIdx OBJECT-TYPE SYNTAX INTEGER { atei1(1), atei2(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Since more than one endpoint may be defined per isdn entity, this field is a simple index. It corresponds to isdnEndpointIdx in the isdn MIB." -- DEFVAL { atei1 } ::= { prtIsdnEndpointEntry 4} prtIsdnEndpointTeiType OBJECT-TYPE SYNTAX INTEGER { dynamic(1), static(2), notApplicable(255) } MAX-ACCESS read-create STATUS current DESCRIPTION "The type of TEI (Terminal Endpoint Identifier) used for this Terminal Endpoint. In case of dynamic(1), the TEI value is selected by the switch. In case of static(2), a valid TEI value has to be entered in the isdnEndpointTeiValue object. interface type as well as the Terminal Endpoint type. static(2). On Basic Rate interfaces the default value is dynamic(1) for isdn(63) Terminal Endpoints. It corresponds to isdnEndpointTeiType in the isdn MIB." ::= { prtIsdnEndpointEntry 5} prtIsdnEndpointTeiValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "When the TEI Type is static, the value of the TEI should be between 0 and 63. Else, it is not selectable by user. 255 = notApplicable. It corresponds to isdnEndpointTeiValue in the isdn MIB" ::= { prtIsdnEndpointEntry 6 } prtIsdnEndpointSpid OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "The Service profile IDentifier (SPID) information for this Terminal Endpoint. It is is composed of 9-20 numeric characters. It corresponds to isdnEndpointSpid in the isdn MIB." ::= { prtIsdnEndpointEntry 7 } prtIsdnEndpointBearerCh OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), anyChannel (2), channelB1 (3), channelB2 (4) } MAX-ACCESS read-create STATUS current DESCRIPTION "This is the selected dialing channel. anyChannel - the system selects the dialing channel." ::= { prtIsdnEndpointEntry 8} prtIsdnEndpointRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This field indicates whether to consider this endpoint or not. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { prtIsdnEndpointEntry 9} prtIsdnDirectoryTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtIsdnDirectoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the table objects is valid only to the TmpCnfg entry." ::= { prtIsdnCnfg 3} prtIsdnDirectoryEntry OBJECT-TYPE SYNTAX PrtIsdnDirectoryEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX { prtIsdnDirectoryCnfgIdx, prtIsdnDirectorySltIdx, prtIsdnDirectoryPrtIdx } ::= { prtIsdnDirectoryTable 1} PrtIsdnDirectoryEntry ::= SEQUENCE { prtIsdnDirectoryCnfgIdx Integer32, prtIsdnDirectorySltIdx INTEGER, prtIsdnDirectoryPrtIdx Integer32, prtIsdnDirectoryLocalAddr DisplayString, prtIsdnDirectoryLocalSubAddr DisplayString, prtIsdnDirectoryRemoteAddr DisplayString, prtIsdnDirectoryRemoteSubAddr DisplayString, prtIsdnDirectoryPrtNu Integer32, prtIsdnDirectoryTeiId Integer32, prtIsdnDirectoryRowStatus RowStatus, prtIsdnDirectoryLocalAddr2 DisplayString, prtIsdnDirectoryLocalSubAddr2 DisplayString, prtIsdnDirectoryRemoteAddr2 DisplayString, prtIsdnDirectoryRemoteSubAddr2 DisplayString } prtIsdnDirectoryCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtIsdnDirectoryEntry 1} prtIsdnDirectorySltIdx OBJECT-TYPE SYNTAX INTEGER { io1(5), io2(6), io3(7), io4(8), io5(9), io6(10), io7(11), io8(12), io9(13), io10(14), io11(15), io12(16), kmxMlA (103), kmxMlB (104), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the card is inserted. For MX300/30 ports: io1(5) = isdn1(5) and io2(6) = isdn2(6). In ?004 Unit the entries io6(10)..io12(16) are not valid For KM2100/4 Valid entries are 'kmxMlA ' or 'kmxMlB'" ::= { prtIsdnDirectoryEntry 2} prtIsdnDirectoryPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "For MAXcess this is the internal port number: 101, 102,.... For KM-2100 the port index is calculated as follows: 100*Slot+Ch" ::= { prtIsdnDirectoryEntry 3} prtIsdnDirectoryLocalAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(17..20)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters) " ::= { prtIsdnDirectoryEntry 4} prtIsdnDirectoryLocalSubAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(4..6)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)" ::= { prtIsdnDirectoryEntry 5} prtIsdnDirectoryRemoteAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(17..20)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)" ::= { prtIsdnDirectoryEntry 6} prtIsdnDirectoryRemoteSubAddr OBJECT-TYPE SYNTAX DisplayString (SIZE(4..6)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)" ::= { prtIsdnDirectoryEntry 7} prtIsdnDirectoryPrtNu OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is the external port number connected to this entry." DEFVAL { 1 } ::= { prtIsdnDirectoryEntry 8} prtIsdnDirectoryTeiId OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is the abstract terminal id if relevant, connected to this entry." DEFVAL { 1 } ::= { prtIsdnDirectoryEntry 9} prtIsdnDirectoryRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This is the status for the row. It allows to know whether to consider this row or not. The only possible supported RowStatus vaules are active (1) and destroy (6)." ::= { prtIsdnDirectoryEntry 10} prtIsdnDirectoryLocalAddr2 OBJECT-TYPE SYNTAX DisplayString (SIZE(17..20)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the second local address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank (20 characters)" ::= { prtIsdnDirectoryEntry 11} prtIsdnDirectoryLocalSubAddr2 OBJECT-TYPE SYNTAX DisplayString (SIZE(4..6)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the second local subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters)" ::= { prtIsdnDirectoryEntry 12} prtIsdnDirectoryRemoteAddr2 OBJECT-TYPE SYNTAX DisplayString (SIZE(17..20)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the second remote address associated with this entry. - For MX: Size=17 , Default=0 (17 characters) - For KM: Size=20, Default=blank(20 characters) " ::= { prtIsdnDirectoryEntry 13} prtIsdnDirectoryRemoteSubAddr2 OBJECT-TYPE SYNTAX DisplayString (SIZE(4..6)) MAX-ACCESS read-create STATUS current DESCRIPTION "This is the second remote subaddress associated with this entry. - For MX: Size=6 , Default=0 (6 characters) - For KM: Size=4 , Default=blank (4 characters) " ::= { prtIsdnDirectoryEntry 14} -- This table is an extension for new version of MAXcess -- modules. prtFrPlusCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtFrPlusCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The write operation into the Table Objects is valid only to the TmpCnfg entry." ::= {prtFrPlusCnfg 1} prtFrPlusCnfgEntry OBJECT-TYPE SYNTAX PrtFrPlusCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtFrPlusCnfgIdx, prtFrPlusSltIdx, prtFrPlusPrtIdx } ::= { prtFrPlusCnfgTable 1} PrtFrPlusCnfgEntry ::= SEQUENCE { prtFrPlusCnfgIdx Integer32, prtFrPlusSltIdx INTEGER, prtFrPlusPrtIdx Integer32, prtFrPlusNotSegmentedPriorities OCTET STRING } prtFrPlusCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. " ::= { prtFrPlusCnfgEntry 1} prtFrPlusSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable(255) } MAX-ACCESS read-only STATUS current DESCRIPTION "Slot Index. For ISDN BRI Ports of MX300/30, io1(5) = isdn1(5) and io2(6) = isdn2(6)." ::= { prtFrPlusCnfgEntry 2} prtFrPlusPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number. This port number should be: - for ISDN cards: inPrt1(101)->inPrt50(150) - for MHS1 card : exPrt1(1) - for MHS3, MLS3 cards: exPrt1(1)->exPrt3(3) - for MLS6 cards: exPrt1(1)->exPrt6(6)." ::= { prtFrPlusCnfgEntry 3} prtFrPlusNotSegmentedPriorities OBJECT-TYPE SYNTAX OCTET STRING(SIZE(1)) MAX-ACCESS read-write STATUS current DESCRIPTION "This parameter is relevant only for FR+ protocol and asks the MXcess NOT to segment data with specified priorities: from LSB: bit 1 is for priority 1, bit 2 is for priority 2, .... till bit 7 for priority 7. - a priority selected to be segmented : its bit will be '0' - a priority not to be segmented : its bit will be '1' Default is 00000000; i.e, segment all priorities." DEFVAL { '00'H } ::= { prtFrPlusCnfgEntry 4 } -- This table is an extension of prtExPh1MlCnfgTable for MTML cards -- of MP-2200 and MP-2100 prtMl4CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtMl4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is an extension table for MTML-4 card parameters." ::= {prtMl4Cnfg 1} prtMl4CnfgEntry OBJECT-TYPE SYNTAX PrtMl4CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtMl4CnfgIdx, prtMl4SltIdx, prtMl4PrtIdx } ::= { prtMl4CnfgTable 1} PrtMl4CnfgEntry ::= SEQUENCE { prtMl4CnfgIdx Integer32, prtMl4SltIdx INTEGER, prtMl4PrtIdx INTEGER, prtMl4SigProfile INTEGER, prtMl4CGA INTEGER, prtMl4Oos INTEGER, prtMl4VoiceOos OCTET STRING, prtMl4DataOos OCTET STRING, prtMl4Service INTEGER, prtMl4IpAddress IpAddress, prtMl4IpMask IpAddress, prtMl4SignalingMode INTEGER, prtMl4EchoCanceler INTEGER, prtMl4OosErrorSource INTEGER, prtMl4OosEntryThreshold Integer32, prtMl4OosExitThreshold Integer32, prtMl4LogicalLinkId Integer32, prtMl4DedicatedTs Integer32, prtMl4RemCrc INTEGER, prtMl4CrossConnectLevel INTEGER, prtMl4PppEchoFailDetection INTEGER, prtMl4EcanCasControl INTEGER } prtMl4CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= { prtMl4CnfgEntry 1} prtMl4SltIdx OBJECT-TYPE SYNTAX INTEGER { clA (3), clB (4), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted." ::= { prtMl4CnfgEntry 2} prtMl4PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), exPrt5 (5), exPrt6 (6), exPrt7 (7), exPrt8 (8), inPrt1 (101), inPrt2 (102), inPrt3 (103), inPrt4 (104), inPrt5 (105), inPrt6 (106), inPrt7 (107), inPrt8 (108), inPrt9 (109), inPrt10 (110), inPrt11 (111), inPrt12 (112), inPrt13 (113), inPrt14 (114), inPrt15 (115), inPrt16 (116), inPrt17 (117), inPrt18 (118), inPrt19 (119), inPrt20 (120), inPrt21 (121), inPrt22 (122), inPrt23 (123), inPrt24 (124), inPrt25 (125), inPrt26 (126), inPrt27 (127), inPrt28 (128), inPrt29 (129), inPrt30 (130), inPrt31 (131), inPrt32 (132), inPrt33 (133), inPrt34 (134), inPrt35 (135), inPrt36 (136), inPrt37 (137), inPrt38 (138), inPrt39 (139), inPrt40 (140), inPrt41 (141), inPrt42 (142), inPrt43 (143), inPrt44 (144), inPrt45 (145), inPrt46 (146), inPrt47 (147), inPrt48 (148), inPrt49 (149), inPrt50 (150), inPrt51 (151), inPrt52 (152), inPrt53 (153), inPrt54 (154), inPrt55 (155), inPrt56 (156), inPrt57 (157), inPrt58 (158), inPrt59 (159), inPrt60 (160), inPrt61 (161), inPrt62 (162), inPrt63 (163), inPrt64 (164), inPrt65 (165), inPrt66 (166), inPrt67 (167), inPrt68 (168), inPrt69 (169), inPrt70 (170), inPrt71 (171), inPrt72 (172), inPrt73 (173), inPrt74 (174), inPrt75 (175), inPrt76 (176), inPrt77 (177), inPrt78 (178), inPrt79 (179), inPrt80 (180), inPrt81 (181), inPrt82 (182), inPrt83 (183), inPrt84 (184) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtMl4CnfgEntry 3} prtMl4SigProfile OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), p1 (3), p2 (4), p3 (5), p4 (6), p5 (7), perTS (8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the Signaling Profile of the port. none - when the Frame is G732N (no MF) or Unframed. p1 = profile 1 p2 = profile 2 p3 = profile 3 p4 = profile 4 p5 = profile 5 perTS = when Signaling Profile is selected per TS." ::= {prtMl4CnfgEntry 4} prtMl4CGA OBJECT-TYPE SYNTAX INTEGER { none (1), trans(2), full (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object selects the method used to signal the CGA state to the other end, through the main link. 'none' - non-transparent mode. When one of the links (main) will be in Out Of Service state, both 'Data/Voice Oos' and 'Oos' will be transmitted to the other end. 'trans' - when one of the links (main) will be in Out Of Service state, 'Data/Voice Oos' will be transmitted to the other end. 'full' - fully-transparent mode. When one of the links (main) will be in Out Of Service state, neither 'Data/Voice Oos' nor 'Oos' will be transmitted to the other end." ::= { prtMl4CnfgEntry 5 } prtMl4Oos OBJECT-TYPE SYNTAX INTEGER { notSupported (2), forcedIdle (3), forcedBusy (4), busyIdle (5), idleBusy (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "'idle' = '0' = on-hook, idle state 'busy' = '1' = off-hook, busy state 'forcedIdle' = SP = both A and B signaling bits are forced to '0' during out-of-service periods. 'forcedBusy' = MK = both A and B signaling bits are forced to '1' during out-of-service periods. 'busyIdle' = MK_SP = A and B bits are forced to '1' for 2.5 seconds; then they are switched to '0' until out-of-service condition disappears. 'idleBusy' = SP_MK = A and B bits are forced to '0' for 2.5 seconds; then they are switched to '1' until out-of-service condition disappears. - for T1: '0'=0 ; '1'=1 - for E1: '0'=1 ; '1'=0 " ::= { prtMl4CnfgEntry 6 } prtMl4VoiceOos OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "Voice Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0." ::= { prtMl4CnfgEntry 7 } prtMl4DataOos OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..4)) MAX-ACCESS read-write STATUS current DESCRIPTION "Data Out-Of-Service code. Valid range: (0 - FF HEX). For agents that do not support this feature, the value will always be 0." ::= { prtMl4CnfgEntry 8 } prtMl4Service OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), leasedLine (2), v51 (3), v52Master (4), v52Slave (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Link Service. leasedLine - usual TDM interface. v51 - V5.1 interface. v52Master - V5.2 Link to Local Exchange. v52Slave - a ML that is transferred to the v52Master." ::= {prtMl4CnfgEntry 9} prtMl4IpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP Address of the port." ::= {prtMl4CnfgEntry 10} prtMl4IpMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP subnet mask of the port." ::= {prtMl4CnfgEntry 11} prtMl4SignalingMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), cas(2), ccs(3), robbedBit(4), other (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Refers to the signaling mode of the port (or framer module). notApplicable(1)- means that no framer is needed for this port (no signaling), or that this object is not relevant. cas(2) means Channel Associated Signaling. Used for E1 Links. ccs(3) is the Common Channel Signaling (the signaling is not within the channels time slot - a TS for signaling is used). robbedBit(4) is a method implementing 7 bits for the voice and 1 bit dedicated for signaling. Used for T1 Links. other (5)- Signaling generally exists though not specifically according to one of the values listed ; this port uses a framer in this case." ::= {prtMl4CnfgEntry 12} prtMl4EchoCanceler OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Echo canceler activation." ::= {prtMl4CnfgEntry 13} prtMl4OosErrorSource OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), framing (3), bpv (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "OOS (Out-of-Service) Error Source. This object is applicable for T1 ports only." ::= {prtMl4CnfgEntry 14} prtMl4OosEntryThreshold OBJECT-TYPE SYNTAX Integer32 (0..999) MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the number of Errors per Second that determine the minimum unacceptable noise level. This value will be the Entry Threshold to the OOS (Out-of-Service) state. This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4). 0=notApplicable." ::= { prtMl4CnfgEntry 15} prtMl4OosExitThreshold OBJECT-TYPE SYNTAX Integer32 (0..99) MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the number of consecutive Error-Free-Seconds before going from OOS state to Normal state. This value will be the Exit Threshold from the OOS (Out-of-Service) state. Units=seconds This object is applicable only when prtMl4OosErrorSource=framing(3) or bpv(4). 0=notApplicable." ::= { prtMl4CnfgEntry 16} prtMl4LogicalLinkId OBJECT-TYPE SYNTAX Integer32 (0..257) MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines for a V5.2 Master ML the Logical Link Id. Valid values are: 0..256. NA=257." ::= { prtMl4CnfgEntry 17} prtMl4DedicatedTs OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-write STATUS current DESCRIPTION "A unique number to identify Dedicated TS of the E1 port (V5.2). It is applicable only when prtMl4Service=v52Slave and prtExPh1MlInbandMng selected is dedicatedTs, dedicatedPpp or dedicatedFr. 1..31 - Dedicated TS of E1 255 - notApplicable Other values are invalid." ::= { prtMl4CnfgEntry 18} prtMl4RemCrc OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the E1 of the Remote device connected to this E1 port, will have CRC-4 or not." ::= { prtMl4CnfgEntry 19 } prtMl4CrossConnectLevel OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), ds0 (2), ds1 (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the cross connect is on DS1 or DS0 (time-slots) level. When cross connect level is ds1, Destination Slot is indicated by prtGenCnfgLinkToSlot, Destination Port is indicated by prtGenCnfgLinkToPort. For Unframed Line Type, cross connect level can be either notApplicable (NC=not connected) or DS1. Otherwise, default value is ds0." ::= { prtMl4CnfgEntry 20 } prtMl4PppEchoFailDetection OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the PPP Echo is taken into account for its Fail Detection. This object is relevant when Inband Mng between devices is Dedicated TS PPP. Default=Disable. Enable - will be selected mainly when a T1/E1 Ring exists and between 2 adjacent Ring devices there is another device or Net, that causes these Ring devices not to sense that the PPP connection between them is lost. In this case, Echo Request should be initiated by the port." ::= { prtMl4CnfgEntry 21 } prtMl4EcanCasControl OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), disable (2), enable (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object enables/disables ECAN (Echo Canceller) control activation/deactivation sent via the A, B, C, D multiframe signaling BITs." ::= { prtMl4CnfgEntry 22 } --prtAcmCnfgTable defines the parameters of the --ACM cards family external ports 1-8 prtAcmCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtAcmCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table for ACM port parameters." ::= {prtAcmCnfg 1} prtAcmCnfgEntry OBJECT-TYPE SYNTAX PrtAcmCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtAcmCnfgIdx, prtAcmSltIdx, prtAcmPrtIdx } ::= { prtAcmCnfgTable 1} PrtAcmCnfgEntry ::= SEQUENCE { prtAcmCnfgIdx Integer32, prtAcmSltIdx INTEGER, prtAcmPrtIdx INTEGER, prtAcmConnect INTEGER, prtAcmActiveState INTEGER, prtAcmAlrString DisplayString } prtAcmCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= { prtAcmCnfgEntry 1} prtAcmSltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16), notApplicable (255) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted." ::= { prtAcmCnfgEntry 2} prtAcmPrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2), exPrt3 (3), exPrt4 (4), exPrt5 (5), exPrt6 (6), exPrt7 (7), exPrt8 (8) , exPrt9 (9) , exPrt10 (10) , exPrt11 (11) , exPrt12 (12) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtAcmCnfgEntry 3} prtAcmConnect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be connected or not. Only a connected port can perform activity." ::= {prtAcmCnfgEntry 4} prtAcmActiveState OBJECT-TYPE SYNTAX INTEGER { low (2), high (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates the Electric Active State of the port." ::= {prtAcmCnfgEntry 5} prtAcmAlrString OBJECT-TYPE SYNTAX DisplayString (SIZE(0..35)) MAX-ACCESS read-write STATUS current DESCRIPTION "Alarm string selected by user for the Inbound ports. This object is applicable only for the Inbound Ports: ext-5..ext-12. For the Outbound Ports (ext-1..ext-4), the size of this string will be 0." ::= {prtAcmCnfgEntry 6} --prtE2CnfgTable defines the parameters of the --E2 card ports prtE2CnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtE2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table for E2 port parameters." ::= {prtE2Cnfg 1} prtE2CnfgEntry OBJECT-TYPE SYNTAX PrtE2CnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtE2CnfgIdx, prtE2SltIdx, prtE2PrtIdx } ::= { prtE2CnfgTable 1} PrtE2CnfgEntry ::= SEQUENCE { prtE2CnfgIdx Integer32, prtE2SltIdx INTEGER, prtE2PrtIdx INTEGER, prtE2Connect INTEGER, prtE2MngOnNationalBit INTEGER } prtE2CnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= { prtE2CnfgEntry 1} prtE2SltIdx OBJECT-TYPE SYNTAX INTEGER { io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique slot position where the module is inserted." ::= { prtE2CnfgEntry 2} prtE2PrtIdx OBJECT-TYPE SYNTAX INTEGER { exPrt1 (1), exPrt2 (2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This attribute indicates a unique port number." ::= { prtE2CnfgEntry 3} prtE2Connect OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether the port should be connected or not. Only a connected port can perform activity." ::= {prtE2CnfgEntry 4} prtE2MngOnNationalBit OBJECT-TYPE SYNTAX INTEGER { no (2), yes (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This attribute indicates whether National Bit will be used for Management or not." ::= {prtE2CnfgEntry 5} --prtLanWanCnfgTable defines the parameters of the Lan-Wan ports --(for HS-ETUB MP card) prtLanWanCnfgTable OBJECT-TYPE SYNTAX SEQUENCE OF PrtLanWanCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a table for Lan-Wan port parameters." ::= {prtLanWanCnfg 1} prtLanWanCnfgEntry OBJECT-TYPE SYNTAX PrtLanWanCnfgEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in table." INDEX {prtLanWanCnfgIdx, prtLanWanSltIdx, prtLanWanPrtIdx } ::= { prtLanWanCnfgTable 1} PrtLanWanCnfgEntry ::= SEQUENCE { prtLanWanCnfgIdx Integer32, prtLanWanSltIdx INTEGER, prtLanWanPrtIdx Integer32, prtLanWanMode INTEGER, prtLanWanDestIf Integer32, prtLanWanEgressVlanMode INTEGER, prtLanWanL2Protocol INTEGER, prtLanWanStpPriority Integer32, prtLanWanStpCost Integer32, prtLanWanToLanVlanMode INTEGER, prtLanWanVlanId Integer32, prtLanWanVlanPriority Integer32, prtLanWanMtu Integer32, prtLanWanVlanType INTEGER } prtLanWanCnfgIdx OBJECT-TYPE SYNTAX Integer32 (1..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates the Idx of the Cnfg (1..100) being accessed. Idx 255 relates to the TmpCnfg. The write operation is valid only to the TmpCnfg." ::= {prtLanWanCnfgEntry 1} prtLanWanSltIdx OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), io1 (5), io2 (6), io3 (7), io4 (8), io5 (9), io6 (10), io7 (11), io8 (12), io9 (13), io10 (14), io11 (15), io12 (16) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates a unique slot position where the module is inserted." ::= {prtLanWanCnfgEntry 2} prtLanWanPrtIdx OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This object indicates a unique number to identify a port in a specific card. Generally, for MP-210X/2200, the Port Index will be according to the external/internal port number: - exPrtX : X - inPrtX : 100 + X For FCD-155, refer to device specification" ::= {prtLanWanCnfgEntry 3} prtLanWanMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), bridge (2), bridgeAndStp (3), layer3SubnetSwitch(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines the working mode of this port. For FCD155, layer3SubnetSwitch is not applicable" ::= {prtLanWanCnfgEntry 4} prtLanWanDestIf OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines the Destination Interface for the frames received by this port. - Switching Table = 100 (it means that the destination interface will be determined by the Switching Table) - inPrtX (internal-X port): 100 + X . For FCD-155 this object is not applicable =0 " ::= {prtLanWanCnfgEntry 5} prtLanWanEgressVlanMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), unmodified (2), tag (3), doubleTag (4), untag (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines what to do with the VLAN frames that exit via the WAN side of the port. This object is not applicable when prtLanWanMode=l3SubnetSwitch(4)." ::= {prtLanWanCnfgEntry 6} prtLanWanL2Protocol OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), none (2), ppp (3), hdlc (4), pppoHdlc (5), mlppp (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "L2 Protocol. When prtLanWanMode=l3SubnetSwitch(4), the only valid value is ppp(3)." ::= {prtLanWanCnfgEntry 7} prtLanWanStpPriority OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the priority field which is contained in the first (in network byte order) octet of the (2 octet long) Port ID." ::= {prtLanWanCnfgEntry 8} prtLanWanStpCost OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The contribution of this port to the path cost of paths towards the spanning tree root which include this port. 802.1D-1990 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN." ::= {prtLanWanCnfgEntry 9} prtLanWanToLanVlanMode OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), unmodified (2), tag (3), doubleTag (4), untag (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object determines what to do with the VLAN frames that come from WAN side of the port and exit towards one of the LAN ports. This object is applicable only when prtLanWanDestIf=100 or 101 (Switching Table or inPrt1)." ::= {prtLanWanCnfgEntry 10} prtLanWanVlanId OBJECT-TYPE SYNTAX Integer32 (0..4095) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the VLAN Id attached to a frame, when the relevant Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is tag or doubleTag. 0=not applicable." ::= {prtLanWanCnfgEntry 11} prtLanWanVlanPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This is the VLAN Priority attached to a frame, when the relevant Vlan Mode (prtLanWanEgressVlanMode or prtLanWanToLanVlanMode) is tag or doubleTag. Valid values: 0..7 255=not applicable." ::= {prtLanWanCnfgEntry 12} prtLanWanMtu OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The size of the largest packet which can be sent/received on the interface, specified in octets. Valid values change per device. 0=not applicable." ::= {prtLanWanCnfgEntry 13} prtLanWanVlanType OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), portBasedVlan (2), ieee802dot1q (3), ieee802dot1qTaggedOnly (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This oject indicates type of VLAN this port is assigned to. Port Base Vlan parameters are defined by objects under radBridgePortBaseVlan" ::= { prtLanWanCnfgEntry 14} -- -- The following table includes the IP addresses of all the NMS to which -- Traps will be sent -- --mngTrapIpTable OBJECT-TYPE -- SYNTAX SEQUENCE OF MngTrapIpEntry -- MAX-ACCESS not-accessible -- STATUS current -- DESCRIPTION -- "This table indicates the destination address of the traps. -- Internally it will be limited to ten addresses. " -- ::= { agnt 7 } -- --mngTrapIpEntry OBJECT-TYPE -- SYNTAX MngTrapIpEntry -- MAX-ACCESS not-accessible -- STATUS current -- INDEX { mngTrapIpIdx } -- ::= { mngTrapIpTable 1 } -- --MngTrapIpEntry ::= -- SEQUENCE { -- mngTrapIpIdx Integer32, -- mngTrapIpIP IpAddress, -- mngTrapIpIPMask IpAddress -- } -- --mngTrapIpIdx OBJECT-TYPE -- SYNTAX Integer32 -- MAX-ACCESS read-only -- STATUS current -- DESCRIPTION -- " This value indicates an index of a specific IP address" -- ::= { mngTrapIpEntry 1 } -- --mngTrapIpIP OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "This value indicates the destination addresses of the traps. " -- ::= { mngTrapIpEntry 2 } -- --mngTrapIpIPMask OBJECT-TYPE -- SYNTAX IpAddress -- MAX-ACCESS read-write -- STATUS current -- DESCRIPTION -- "This value indicates the mask of the destination addresses of the traps. " -- ::= { mngTrapIpEntry 3 } -- -- -- Traps --NOTIFICATIONS muxHubEvents OBJECT-IDENTITY STATUS current DESCRIPTION "The events for ." ::= { muxHub 0 } alarmsTrap NOTIFICATION-TYPE OBJECTS { alrBufDescription } STATUS current DESCRIPTION "This trap is sent whenever alarm occurs in the agent." ::= { muxHubEvents 1 } sanityTrap NOTIFICATION-TYPE OBJECTS { agnSSanityCheckStatus, agnCSaveCnfgIdxCmd } STATUS current DESCRIPTION "This trap is sent after a data base update. It returns the sanity result status and the configuration no. checked. If the result is of Flip DB Sanity Check, the configuration no. sent will be 0. If the result is of Variant Sanity Check, the configuration no. sent will be 100." ::= { muxHubEvents 2 } cnfgFlipTrap NOTIFICATION-TYPE OBJECTS { agnSActiveCnfg } STATUS current DESCRIPTION "This trap is sent upon change of the active Configuration DB. Attached, is the new active Configuration no." ::= { muxHubEvents 3 } flipDbChangeTrap NOTIFICATION-TYPE STATUS current DESCRIPTION "This trap is sent upon change of the active Flip tables (Flip DB)." ::= { muxHubEvents 4 } statusChangedTrap NOTIFICATION-TYPE OBJECTS { agnLed } STATUS current DESCRIPTION "This trap is sent upon any change of the LEDs status." ::= { muxHubEvents 5 } END