TROPIC-SYNCE-MIB DEFINITIONS ::= BEGIN
-- (c) Copyright 2021 Nokia Networks. All rights reserved.
-- This software is the confidential and proprietary property of
-- Nokia and may only be used in accordance with the terms of the
-- license agreement provided with this software.
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY,
Unsigned32, Integer32 FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
TruthValue FROM SNMPv2-TC
ifIndex,
InterfaceIndexOrZero FROM IF-MIB
TropicStateQualifierType,
TropicOperationalCapabilityType,
NokiaSyncStatusMsgType FROM TROPIC-TC
tnShelfIndex FROM TROPIC-SHELF-MIB
tnSlotIndex FROM TROPIC-SLOT-MIB
tnPortModules, tnSyncEMIB FROM TROPIC-GLOBAL-REG
tnSysSwitchId FROM TROPIC-SYSTEM-MIB
AluWdmPtpClockIdentifier FROM TROPIC-PTP-MIB
SnmpAdminString FROM SNMP-FRAMEWORK-MIB;
tnSyncEMibModule MODULE-IDENTITY
LAST-UPDATED "202011201200Z"
ORGANIZATION "Nokia"
CONTACT-INFO "Nokia
Attn: Jeff Donnelly
600 Mountain Avenue
New Providence, NJ 07974
Phone: +1 732 221 6408
Email: jeff.donnelly@nokia.com"
DESCRIPTION "Synchronous Ethernet MIB attributes."
REVISION "202011201200Z"
DESCRIPTION "1) Added the following to tnSyncELineRefTable:
tnSyncELineRefProvQLOfStationClock
tnSyncELineRefIncSSMMsgOfStationClock
tnSyncELineRefIncSSMStatusOfStationClock.
2) Added the following to tnWanSyncEOutgoingForceSsmTrans:
ePRTC(23)
to
eSEC(26).
3) Updated DESCRIPTION of the following:
tnWanSyncEOutgoingForceSsmTrans."
REVISION "202011131200Z"
DESCRIPTION "1) Updated DESCRIPTION of the following:
tnSyncESystemQL
tnSyncEStationClockSystemQL
tnSyncEStationClockSyncMsg
tnSyncESyncMsg.
2) Changed SYNTAX of the following from TruthValue to NokiaSyncStatusMsgType:
tnSyncESyncMsg
tnSyncEStationClockSyncMsg."
REVISION "202011061200Z"
DESCRIPTION "1) Updated DESCRIPTION of the following:
tnSyncEQLDegradeThreshold
tnSyncEStationClockQLThreshold
tnSyncELineRefProvQL
tnSyncELineRefIncSSMMsg
tnSyncEOutgoingForceSsmTrans.
2) Added the following to tnSyncELineRefTable:
tnSyncELineRefIncExtdQLTLVClockID
tnSyncELineRefIncExtdQLTLVMixedClockType
tnSyncELineRefIncExtdQLTLVPartialChain
tnSyncELineRefIncExtdQLTLVNumeEEC
tnSyncELineRefIncExtdQLTLVNumEEC.
3) Added the following to tnSyncEOutgoingForceSsmTrans:
ePRTC(23)
to
eSEC(26)."
REVISION "202001101200Z"
DESCRIPTION "Added the following to tnSyncEBITSPortTable:
tnSyncEBITSPortAlmProfName."
REVISION "201909061200Z"
DESCRIPTION "1) Added the following to tnSyncETable:
tnSyncEAlmProfName.
2) Added the following to tnSyncELineRefTable:
tnSyncELineRefAlmProfName.
3) Added the following to tnSyncEStationClockTable:
tnSyncEStationClockAlmProfName."
REVISION "201809071200Z"
DESCRIPTION "Added the following to tnWanTable:
tnWanDescription."
REVISION "201804061200Z"
DESCRIPTION "Added notApplicable(0) to the following:
tnSyncEBITSPortSaBit
tnSyncEBITSPortOutputSSMTrans
tnSyncEBITSPortOutputAISMode."
REVISION "201802231200Z"
DESCRIPTION "Updated the contact info."
REVISION "201802161200Z"
DESCRIPTION "Added the following to tnSyncELineRefTable:
tnSyncELineRefCurrentFreqOff."
REVISION "201802091200Z"
DESCRIPTION "Added the following to tnSyncETable:
tnSyncEQLDegradeThreshold
tnSyncECurrentActiveLineRefFreqOff ."
REVISION "201709291200Z"
DESCRIPTION "Redefined tnWanSyncEOutgoingForceSsmTrans with the following values:
notApplicable(1),
to
dus(14)."
REVISION "201707071200Z"
DESCRIPTION "Fixed MIB compile issues."
REVISION "201706301200Z"
DESCRIPTION "Added the following table:
tnSyncEPacketswitchControlTable."
REVISION "201705261200Z"
DESCRIPTION "Added the following to tnSyncEBITSPortLineCode:
notApplicable(3)."
REVISION "201704211200Z"
DESCRIPTION "Modified MAX_ACCESS of tnSyncEBITSPortDirection from
read-only to read-create."
REVISION "201611291200Z"
DESCRIPTION "Added the following to tnWanTable:
tnWanOperStatus
tnWanStateQualifier
tnWanOperationalCapability."
REVISION "201611161200Z"
DESCRIPTION "Updated the contact info."
REVISION "201610191200Z"
DESCRIPTION "Added the following to tnSyncELineRefAssignedPort:
x7(38),
x8(39),
x9(40),
x10(41),
x11(42),
x12(43)."
REVISION "201608241200Z"
DESCRIPTION "1) Added the following tables:
tnWanTable.
2) Added the following to tnWanTable:
tnWanAlmProfName
tnWanSyncEOprMode
tnWanSyncEOutgoingForceSsmTrans
tnWanAdminStatus."
REVISION "201308261200Z"
DESCRIPTION "Updated description of the following:
tnSyncELineRefIncSSMSupp
tnSyncELineRefProvQL
tnSyncEBITSPortSignalType
tnSyncEBITSPortOutputSSMTrans
tnSyncEBITSPortOutputAISMode
tnSyncEBITSPortLineImpedance."
REVISION "201307121200Z"
DESCRIPTION "Added the following to tnSyncELineRefAssignedPort:
x5(32),
x6(33),
m1(34),
m2(35),
m3(36),
m4(37)."
REVISION "201306011200Z"
DESCRIPTION "1) Added the following to tnSyncEBITSPortTable:
tnSyncEBITSPortLineCode
tnSyncEBITSPortLbo.
2) Added the following to DESCRIPTION Of
tnSyncEBITSPortSignalType
DS1 SF(4)
DS1 ESF(5)."
REVISION "201212201200Z"
DESCRIPTION "Added the following to tnSyncEBITSPortTable:
tnSyncEBITSPortLineImpedance."
REVISION "201209011200Z"
DESCRIPTION "1) Added DEFVAL to the following:
tnSyncESyncMsg - false
tnSyncELineRefAssignedPort - none
tnSyncELineRefPriority - 0
tnSyncELineRefAdminState - up
tnSyncELineRefProvQL - 0.
2) Added the following to tnSyncEActiveRef:
lineRef3(6),
lineRef5(7).
3) Added the following to DESCRIPTION of tnSyncESwCmdLineRef:
5 - lineref4
6 - lineref5.
4) Added the following to tnSyncELineRefTable:
tnSyncELineRefAssociatedPort
tnSyncELineRefPriorityOfStationClock
tnSyncELineRefLockOutOfStationClock
tnSyncELineRefSwStateOfStationClock.
5) Added the following tables:
tnSyncEStationClockTable
tnSyncEBITSPortTable."
REVISION "201205081200Z"
DESCRIPTION "1) Added the following to tnSyncELineRefAssignedPort:
c22(25),
c23(26),
c24(27),
x1(28),
x2(29),
x3(30),
x4(31).
2) Added infinity time (999999) to tnSyncEWTR."
REVISION "201112211200Z"
DESCRIPTION "Modified descriptions of following:
tnSyncESystemQL
tnSyncELineRefIncSSMMsg
tnSyncELineRefProvQL."
REVISION "201108191200Z"
DESCRIPTION "1) Added the following to tnSyncELineRefAssignedPort:
c13(16)
c14(17)
c15(18)
c16(19)
c17(20)
c18(21)
c19(22)
c20(23)
c21(24).
2) Added the following to tnSyncEOutgoingForceSsmTrans:
dus(13).
3) Redefined enum values for the following attributes:
tnSyncELineRefOperState
tnSyncELineRefState.
4) Modified MAX_ACCESS of tnSyncELineLockOut from
read-create to read-only.
5) Modified DEFVAL of tnSyncELineRefIncSSMSupp.
6) Modified DESCRIPTION for the following attributes:
tnSyncELineRefIncSSMMsg
tnSyncELineRefProvQL."
REVISION "201107221200Z"
DESCRIPTION "1) Added SSM SyncE MIB tables:
tnSyncEControlTable
tnSyncEPortTable.
2) Redefined enum values for the following attributes:
tnSyncEActiveRef
tnSyncELineRefOperState.
3) Added the following to tnSyncETable:
tnSyncESystemQL.
4) Added the following to tnSyncELineRefTable:
tnSyncELineRefIncSSMMsg
tnSyncELineRefIncSSMStatus
tnSyncELineRefIncSSMSupp
tnSyncELineRefProvQL.
5) Modified DESCRIPTION of tnSyncESwCmdLineRef."
REVISION "201011301200Z"
DESCRIPTION "Changed description for the values of
tnSyncESwCmdLineRef."
REVISION "201011221200Z"
DESCRIPTION "Added tnSyncETable and tnSyncELineRefTable."
::= { tnPortModules 6 }
tnSyncEConf OBJECT IDENTIFIER ::= { tnSyncEMIB 1 }
tnSyncEGroups OBJECT IDENTIFIER ::= { tnSyncEConf 1 }
tnSyncECompliances OBJECT IDENTIFIER ::= { tnSyncEConf 2 }
tnSyncEObjs OBJECT IDENTIFIER ::= { tnSyncEMIB 2 }
tnSyncEBasics OBJECT IDENTIFIER ::= { tnSyncEObjs 1 }
--------------------------------------------------------------------------------
-- Synchronous Ethernet Table
--------------------------------------------------------------------------------
tnSyncETable OBJECT-TYPE
SYNTAX SEQUENCE OF TnSyncEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of Sync-E attributes."
::= { tnSyncEBasics 1 }
tnSyncEEntry OBJECT-TYPE
SYNTAX TnSyncEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { tnShelfIndex,
tnSlotIndex }
::= { tnSyncETable 1 }
TnSyncEntry ::=
SEQUENCE {
tnSyncESyncMsg NokiaSyncStatusMsgType,
tnSyncEActiveRef INTEGER,
tnSyncEWTR Unsigned32,
tnSyncESwCmdLineRef Unsigned32,
tnSyncEClkModState INTEGER,
tnSyncESystemQL Integer32,
tnSyncEQLDegradeThreshold Integer32,
tnSyncECurrentActiveLineRefFreqOff Integer32,
tnSyncEAlmProfName OCTET STRING
}
tnSyncESyncMsg OBJECT-TYPE
SYNTAX NokiaSyncStatusMsgType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Determines if the timing reference selection for system
timing uses Synchronization Status Message (SSM) Quality
Levels or Enhanced Quality Levels."
DEFVAL { false }
::= { tnSyncEEntry 1 }
tnSyncEActiveRef OBJECT-TYPE
SYNTAX INTEGER {
none(1),
lineRef0(2),
lineRef1(3),
lineRef2(4),
lineRef3(5),
lineRef4(6),
lineRef5(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The ID of the association line reference."
DEFVAL { none }
::= { tnSyncEEntry 2 }
tnSyncEWTR OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The system timing WTR.
Current configurable range: 0 to 12, and 999999."
DEFVAL { 5 }
::= { tnSyncEEntry 3 }
tnSyncESwCmdLineRef OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The third byte represents the switch command:
1 - nocmd
2 - clear
3 - lockout
4 - forceswitch
5 - mannual
6 - auto
7 - clearlockout.
The last byte represents the line reference switch to:
0 - internal
1 - lineref0
2 - lineref1
3 - lineref2
4 - lineref3
5 - lineref4
6 - lineref5."
::= { tnSyncEEntry 4 }
tnSyncEClkModState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
locked(2),
autonomousHoldOver(3),
autonomousFreeRunning(4),
forcedFreeRunning(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Sync-E clock mode state."
::= { tnSyncEEntry 5 }
tnSyncESystemQL OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the system quality level (SSM), shown
in following:
31 - not applicable
When the NE is in SDH mode:
0 - quality unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC.
When the NE is in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC."
::= { tnSyncEEntry 6 }
tnSyncEQLDegradeThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The threshold value of SSM quality level degradation
for systme timing reference.
When the NE is in SDH mode:
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC - Default
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC.
When the NE is in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3 - Default
23 - ePRTC
24 - PRTC
25 - ePRC."
::= { tnSyncEEntry 7 }
tnSyncECurrentActiveLineRefFreqOff OBJECT-TYPE
SYNTAX Integer32
UNITS "ppb"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current frequency offset of the active timing reference."
::= { tnSyncEEntry 8 }
tnSyncEAlmProfName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..40))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
::= { tnSyncEEntry 9 }
-------------------------------------------------------------------------------
-- Synchronous Ethernet Timing Line Reference Map Table
--------------------------------------------------------------------------------
tnSyncELineRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnSyncELineRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of VTS map."
::= { tnSyncEBasics 2 }
tnSyncELineRefEntry OBJECT-TYPE
SYNTAX TnSyncELineRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { tnShelfIndex,
tnSlotIndex,
tnSyncELineRefIndex }
::= { tnSyncELineRefTable 1 }
TnSyncELineRefEntry ::=
SEQUENCE {
tnSyncELineRefIndex Unsigned32,
tnSyncELineRefAssignedPort INTEGER,
tnSyncELineRefPriority Unsigned32,
tnSyncELineRefAdminState INTEGER,
tnSyncELineRefOperState INTEGER,
tnSyncELineLockOut TruthValue,
tnSyncELineRefState INTEGER,
tnSyncELineRefSwState INTEGER,
tnSyncELineRefIncSSMMsg Integer32,
tnSyncELineRefIncSSMStatus Integer32,
tnSyncELineRefIncSSMSupp INTEGER,
tnSyncELineRefProvQL Integer32,
tnSyncELineRefAssociatedPort InterfaceIndexOrZero,
tnSyncELineRefPriorityOfStationClock Unsigned32,
tnSyncELineRefLockOutOfStationClock TruthValue,
tnSyncELineRefSwStateOfStationClock INTEGER,
tnSyncELineRefCurrentFreqOff Integer32,
tnSyncELineRefAlmProfName OCTET STRING,
tnSyncELineRefIncExtdQLTLVClockID AluWdmPtpClockIdentifier,
tnSyncELineRefIncExtdQLTLVMixedClockType INTEGER,
tnSyncELineRefIncExtdQLTLVPartialChain INTEGER,
tnSyncELineRefIncExtdQLTLVNumeEEC Unsigned32,
tnSyncELineRefIncExtdQLTLVNumEEC Unsigned32,
tnSyncELineRefProvQLOfStationClock Integer32,
tnSyncELineRefIncSSMMsgOfStationClock Integer32,
tnSyncELineRefIncSSMStatusOfStationClock Integer32
}
tnSyncELineRefIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The ifIndex of the line reference table."
::= { tnSyncELineRefEntry 1 }
tnSyncELineRefAssignedPort OBJECT-TYPE
SYNTAX INTEGER {
none(1),
l1(2),
l2(3),
c1(4),
c2(5),
c3(6),
c4(7),
c5(8),
c6(9),
c7(10),
c8(11),
c9(12),
c10(13),
c11(14),
c12(15),
c13(16),
c14(17),
c15(18),
c16(19),
c17(20),
c18(21),
c19(22),
c20(23),
c21(24),
c22(25),
c23(26),
c24(27),
x1(28),
x2(29),
x3(30),
x4(31),
x5(32),
x6(33),
m1(34),
m2(35),
m3(36),
m4(37),
x7(38),
x8(39),
x9(40),
x10(41),
x11(42),
x12(43)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The assigned port for the line reference."
DEFVAL { none }
::= { tnSyncELineRefEntry 2 }
tnSyncELineRefPriority OBJECT-TYPE
SYNTAX Unsigned32 (0..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Line reference priority.
Current configurable range: 0 to 8."
DEFVAL { 0 }
::= { tnSyncELineRefEntry 3 }
tnSyncELineRefAdminState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative state of the line reference."
DEFVAL { up }
::= { tnSyncELineRefEntry 4 }
tnSyncELineRefOperState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The operating state of the line reference."
::= { tnSyncELineRefEntry 5 }
tnSyncELineLockOut OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "If lock out line reference or not."
::= { tnSyncELineRefEntry 6 }
tnSyncELineRefState OBJECT-TYPE
SYNTAX INTEGER {
notAssigned(1),
normal(2),
signalFailure(3),
wtr(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Sync-E line reference state."
::= { tnSyncELineRefEntry 7 }
tnSyncELineRefSwState OBJECT-TYPE
SYNTAX INTEGER {
nocmd(1),
forced(2),
mansw(3),
lockout(4),
wtr(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Sync-E line reference switch state."
::= { tnSyncELineRefEntry 8 }
tnSyncELineRefIncSSMMsg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the current value of incoming
QL on that port.
30 - unstable
31 - not applicable
When the NE works in SDH mode:
0 - Unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC
When the NE works in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC
It's applicable only to the timing port with SSM
capabilities."
::= { tnSyncELineRefEntry 9 }
tnSyncELineRefIncSSMStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the current status of incoming
QL on that port.
0: Valid
1: Invalid
2: Not Supported
3: Not Applicable
It's applicable only to the timing port with SSM
capabilities."
::= { tnSyncELineRefEntry 10 }
tnSyncELineRefIncSSMSupp OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Enable or disable the line reference incoming QL processing."
DEFVAL { disable }
::= { tnSyncELineRefEntry 11 }
tnSyncELineRefProvQL OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Manually provisioned incoming SSM value for the line
reference. The value can be:
0 - AUTO
When the NE is in SDH mode:
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC
When the NE works in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC
Note: The parameter can be provisioned only when
SyncELineRefIncSSMSupp is enabled."
DEFVAL { 0 }
::= { tnSyncELineRefEntry 12 }
tnSyncELineRefAssociatedPort OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The associated physical port of the line
reference. This parameter replaces
tnSyncELineRefAssignedPort in order to support
assigning a line reference to a port in other
slots."
DEFVAL { 0 }
::= { tnSyncELineRefEntry 13 }
tnSyncELineRefPriorityOfStationClock OBJECT-TYPE
SYNTAX Unsigned32 (0..8)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Line reference priority for the output station
clock.
Current configurable range: 0 to 8."
DEFVAL { 0 }
::= { tnSyncELineRefEntry 14 }
tnSyncELineRefLockOutOfStationClock OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "If lock out the line reference or not for the
output station clock."
::= { tnSyncELineRefEntry 15 }
tnSyncELineRefSwStateOfStationClock OBJECT-TYPE
SYNTAX INTEGER {
nocmd(1),
forced(2),
mansw(3),
lockout(4),
wtr(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Sync-E line reference switch state of the
output station clock."
::= { tnSyncELineRefEntry 16 }
tnSyncELineRefCurrentFreqOff OBJECT-TYPE
SYNTAX Integer32
UNITS "ppb"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current frequency offset of the timing reference."
::= { tnSyncELineRefEntry 17 }
tnSyncELineRefAlmProfName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..40))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
::= { tnSyncELineRefEntry 18 }
tnSyncELineRefIncExtdQLTLVClockID OBJECT-TYPE
SYNTAX AluWdmPtpClockIdentifier
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incoming Extended QL TLV Clock ID."
::= { tnSyncELineRefEntry 19 }
tnSyncELineRefIncExtdQLTLVMixedClockType OBJECT-TYPE
SYNTAX INTEGER {
eEECFull(1),
eEECMixedEEC(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incoming Extended QL TLV Mixed Clock Type Flag."
::= { tnSyncELineRefEntry 20 }
tnSyncELineRefIncExtdQLTLVPartialChain OBJECT-TYPE
SYNTAX INTEGER {
completeChain(1),
partialChain(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incoming Extended QL TLV Partial Chain Flag."
::= { tnSyncELineRefEntry 21 }
tnSyncELineRefIncExtdQLTLVNumeEEC OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incoming Extended QL TLV Number of eEEC."
::= { tnSyncELineRefEntry 22 }
tnSyncELineRefIncExtdQLTLVNumEEC OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incoming Extended QL TLV Number of EEC."
::= { tnSyncELineRefEntry 23 }
tnSyncELineRefProvQLOfStationClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Manually provisioned incoming SSM value
of the line reference output timing.
The value can be:
0 - AUTO
When the NE is in SDH mode:
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC
When the NE works in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC
Note: The parameter can be provisioned only when
SyncELineRefIncSSMSupp is enabled."
DEFVAL { 0 }
::= { tnSyncELineRefEntry 24 }
tnSyncELineRefIncSSMMsgOfStationClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the current value of incoming
QL for output timing on that port.
30 - unstable
31 - not applicable
When the NE works in SDH mode:
0 - Unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC
When the NE works in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC
It's applicable only to the timing port with SSM
capabilities."
::= { tnSyncELineRefEntry 25 }
tnSyncELineRefIncSSMStatusOfStationClock OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the current status of incoming
QL on that port for output timing.
0: Valid
1: Invalid
2: Not Supported
3: Not Applicable
It's applicable only to the timing port with SSM
capabilities."
::= { tnSyncELineRefEntry 26 }
--------------------------------------------------------------------------------
-- Synchronous Ethernet Control Table
--------------------------------------------------------------------------------
tnSyncEControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnSyncControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of Sync-E Control attributes."
::= { tnSyncEBasics 3 }
tnSyncEControlEntry OBJECT-TYPE
SYNTAX TnSyncControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { tnShelfIndex,
tnSlotIndex }
::= { tnSyncEControlTable 1 }
TnSyncControlEntry ::=
SEQUENCE {
tnSyncEControlEECEnable INTEGER
}
tnSyncEControlEECEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "enable - The Synchronous Ethernet is supported
for the pack and the synchronization
attributes can be configured.
disable - The Synchronous Ethernet is not supported
for the pack and the synchronization
attributes can not be configured."
DEFVAL { disable }
::= { tnSyncEControlEntry 1 }
--------------------------------------------------------------------------------
-- Synchronous Ethernet Port Table
--------------------------------------------------------------------------------
tnSyncEPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnSyncPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of Sync-E Port attributes."
::= { tnSyncEBasics 4 }
tnSyncEPortEntry OBJECT-TYPE
SYNTAX TnSyncPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { ifIndex }
::= { tnSyncEPortTable 1 }
TnSyncPortEntry ::=
SEQUENCE {
tnSyncEOprMode INTEGER,
tnSyncEOutgoingForceSsmTrans INTEGER
}
tnSyncEOprMode OBJECT-TYPE
SYNTAX INTEGER {
sync(1),
non-sync(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The port Synchronous Ethernet Operation Mode. When
the port is in SYNC mode, recovered clock of its
input signal can be selected as a reference clock
to the system clock. When the port is in NON-SYNC
mode, the recovered clock of its input signal shall
not be a candidate to system timing references."
DEFVAL { sync }
::= { tnSyncEPortEntry 1 }
tnSyncEOutgoingForceSsmTrans OBJECT-TYPE
SYNTAX INTEGER {
act(1),
prc(2),
ssua(3),
ssub(4),
sec(5),
dnu(6),
stu(7),
prs(8),
st2(9),
sts3e(10),
st3(11),
none(12),
dus(13),
ePRTC(23),
pRTC(24),
ePRC(25),
eSEC(26)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The port SSM/Quality Level Transmission value.
The value can be:
In SDH mode - act, prc, ssua, ssub, sec, dnu,
ePRTC, PRTC, ePRC, eSEC, none;
In sonet mode - act, stu, prs, st2, sts3e, st3,
ePRTC, PRTC, ePRC, dus, none."
DEFVAL { act }
::= { tnSyncEPortEntry 2 }
--------------------------------------------------------------------------------
-- Synchronous Ethernet Station Clock Table
--------------------------------------------------------------------------------
tnSyncEStationClockTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnSyncEStationClockEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of Sync-E station clock attributes."
::= { tnSyncEBasics 5 }
tnSyncEStationClockEntry OBJECT-TYPE
SYNTAX TnSyncEStationClockEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { tnShelfIndex,
tnSlotIndex }
::= { tnSyncEStationClockTable 1 }
TnSyncEStationClockEntry ::=
SEQUENCE {
tnSyncEStationClockSyncMsg NokiaSyncStatusMsgType,
tnSyncEStationClockActiveRef INTEGER,
tnSyncEStationClockWTR Unsigned32,
tnSyncEStationClockSwCmdLineRef Unsigned32,
tnSyncEStationClockSystemQL Integer32,
tnSyncEStationClockQLThreshold Integer32,
tnSyncEStationClockOutSel INTEGER,
tnSyncEStationClockAlmProfName OCTET STRING
}
tnSyncEStationClockSyncMsg OBJECT-TYPE
SYNTAX NokiaSyncStatusMsgType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Determines if the timing reference selection for
station clock timing uses Synchronization Status Message
(SSM) Quality Levels or Enhanced Quality Levels."
DEFVAL { false }
::= { tnSyncEStationClockEntry 1 }
tnSyncEStationClockActiveRef OBJECT-TYPE
SYNTAX INTEGER {
none(1),
lineRef0(2),
lineRef1(3),
lineRef2(4),
lineRef3(5),
lineRef4(6),
lineRef5(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The ID of the association line reference."
DEFVAL { none }
::= { tnSyncEStationClockEntry 2 }
tnSyncEStationClockWTR OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The station clock timing WTR.
Current configurable range: 0 to 12, and 999999."
DEFVAL { 5 }
::= { tnSyncEStationClockEntry 3 }
tnSyncEStationClockSwCmdLineRef OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The third byte represents the switch command:
1 - nocmd
2 - clear
3 - lockout
4 - forceswitch
5 - mannual
6 - auto
7 - clearlockout.
The last byte represents the line reference switch to:
0 - internal
1 - lineref0
2 - lineref1
3 - lineref2
4 - lineref3
5 - lineref4
6 - lineref5."
::= { tnSyncEStationClockEntry 4 }
tnSyncEStationClockSystemQL OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the system quality level (SSM) for
the output timing clock, shown in following:
31 - not applicable
When the NE is in SDH mode:
0 - quality unknown
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC.
When the NE is in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
20 - PNO
23 - ePRTC
24 - PRTC
25 - ePRC."
::= { tnSyncEStationClockEntry 5}
tnSyncEStationClockQLThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the threshold value for the quality
level i.e., SSM value for squelching the output
towards timing output. If the quality value of
the current selected signal for the output is
below the threshold value, the output will be
squelched. The squelching can be disabled by
means of using the value DNU or DUS.
When the NE is in SDH mode:
1 - PRC
2 - SSU_A
3 - SSU_B
4 - SEC
5 - DNU
23 - ePRTC
24 - PRTC
25 - ePRC
26 - eSEC.
When the NE is in SONET mode:
11 - PRS
12 - STU
13 - ST2
14 - TNC
15 - ST3E
16 - ST3
17 - SMC
18 - ST4
19 - DUS
23 - ePRTC
24 - PRTC
25 - ePRC.
Default value:
SEC - for node working in SDH mode
ST3 - for node working in SONET mode"
DEFVAL { 4 }
::= { tnSyncEStationClockEntry 6}
tnSyncEStationClockOutSel OBJECT-TYPE
SYNTAX INTEGER {
outtim(1),
setg(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies which signal is selected for the output
station clock:
OUTTIM - Output is selected from output timing
selection process
SETG - Output is selected from system internal
timing The ID of the association line
reference."
DEFVAL { outtim }
::= { tnSyncEStationClockEntry 7 }
tnSyncEStationClockAlmProfName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..40))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
::= { tnSyncEStationClockEntry 8 }
--------------------------------------------------------------------------------
-- Synchronous Ethernet BITS Port Table
--------------------------------------------------------------------------------
tnSyncEBITSPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnSyncEBITSPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of BITS port attributes."
::= { tnSyncEBasics 6 }
tnSyncEBITSPortEntry OBJECT-TYPE
SYNTAX TnSyncEBITSPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { ifIndex }
::= { tnSyncEBITSPortTable 1 }
TnSyncEBITSPortEntry ::=
SEQUENCE {
tnSyncEBITSPortDirection INTEGER,
tnSyncEBITSPortSignalType Integer32,
tnSyncEBITSPortSaBit INTEGER,
tnSyncEBITSPortOutputSSMTrans INTEGER,
tnSyncEBITSPortOutputAISMode INTEGER,
tnSyncEBITSPortLineImpedance INTEGER,
tnSyncEBITSPortLineCode INTEGER,
tnSyncEBITSPortLbo INTEGER,
tnSyncEBITSPortAlmProfName OCTET STRING
}
tnSyncEBITSPortDirection OBJECT-TYPE
SYNTAX INTEGER {
input(1),
output(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Indicate the direction of the BITS port."
::= { tnSyncEBITSPortEntry 1 }
tnSyncEBITSPortSignalType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specify the signal type for the BITS interface:
0 - 2MHz
1 - unframed E1
2 - framed E1 without SSM
3 - framed E1 with SSM
4 - DS1 SF
5 - DS1 ESF.
In SDH mode, 2MHz and E1 signal types are valid
and 2MHz is the default value. In SONET mode,
only the DS1 signal types are valid and DS1 SF
is the default value."
DEFVAL { 0 }
::= { tnSyncEBITSPortEntry 2 }
tnSyncEBITSPortSaBit OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(0),
sa4 (1),
sa5 (2),
sa6 (3),
sa7 (4),
sa8 (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the Sa bit location used to carry the
SSM information. This parameter is only
applicable when tnSyncEBITSPortSignalType = 3
(framed E1 with SSM)"
DEFVAL { sa4 }
::= { tnSyncEBITSPortEntry 3 }
tnSyncEBITSPortOutputSSMTrans OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(0),
act(1),
prc(2),
ssua(3),
ssub(4),
sec(5),
dnu(6),
stu(7),
prs(8),
st2(9),
sts3e(10),
st3(11),
none(12),
dus(13)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The port SSM/Quality Level Transmission value.
The value can be:
In SDH mode - act, prc, ssua, ssub, sec,
dnu, none;
In sonet mode - act, stu, prs, st2, sts3e,
st3, dus, none.
Restriction: The parameter is only applicable
when tnSyncEBITSPortDirection = output and
tnSyncEBITSPortSignalType = 3 (framed E1 with
SSM)or 5 (DS1 ESF)."
DEFVAL { act }
::= { tnSyncEBITSPortEntry 4 }
tnSyncEBITSPortOutputAISMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(0),
aismode(1),
qlmode(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies which signal is inserted for the timing
output port if the output signal is squelched.
The parameter is only applicable for output port
types supporting SSM.
AISMODE - AIS signal is inserted.
QLMODE - DUS is inserted as SSM; output is
squelched.
Restriction: The parameter is only applicable
when tnSyncEBITSPortDirection = output and
tnSyncEBITSPortSignalType = 3 (framed E1 with SSM)
or 5 (DS1 ESF)."
DEFVAL { qlmode }
::= { tnSyncEBITSPortEntry 5 }
tnSyncEBITSPortLineImpedance OBJECT-TYPE
SYNTAX INTEGER {
imp75ohms(1),
imp120ohms(2),
imp100ohms(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Nominal line impedance.
When in SDH mode, imp75ohms or imp120ohms could
be used and the default is imp120ohms. When in
ONET mode, imp100ohms could be used and the default
is imp100ohms."
DEFVAL { imp120ohms }
::= { tnSyncEBITSPortEntry 6 }
tnSyncEBITSPortLineCode OBJECT-TYPE
SYNTAX INTEGER {
b8zs(1),
ami(2),
notApplicable(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Line code. This attribute is applicable when
tnSyncEBITSPortSignalType is DS1 SF or DS1 ESF."
DEFVAL { b8zs }
::= { tnSyncEBITSPortEntry 7 }
tnSyncEBITSPortLbo OBJECT-TYPE
SYNTAX INTEGER {
lbo(1),
lbo1(2),
lbo2(3),
lbo3(4),
lbo4(5),
lbo5(6)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Line equalization value for the BITS output port,
taking one of the following values:
- lbo: no compensation
- lbo1: 0 to 133 feet
- lbo2: 133 to 266 feet
- lbo3: 267 to 399 feet
- lbo4: 400 to 533 feet
- lbo5: 534 to 655 feet
This attribute is applicable when tnSyncEBITSPortSignalType
is DS1 SF or DS1 ESF."
DEFVAL { lbo1 }
::= { tnSyncEBITSPortEntry 8 }
tnSyncEBITSPortAlmProfName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..40))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Alarm profile for BITs port"
::= { tnSyncEBITSPortEntry 9}
--------------------------------------------------------------------------------
-- Wan Table
--------------------------------------------------------------------------------
tnWanTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnWanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of Wan attributes."
::= { tnSyncEBasics 7 }
tnWanEntry OBJECT-TYPE
SYNTAX TnWanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { ifIndex }
::= { tnWanTable 1 }
TnWanEntry ::=
SEQUENCE {
tnWanAlmProfName OCTET STRING,
tnWanSyncEOprMode INTEGER,
tnWanSyncEOutgoingForceSsmTrans INTEGER,
tnWanAdminStatus INTEGER,
tnWanOperStatus INTEGER,
tnWanStateQualifier TropicStateQualifierType,
tnWanOperationalCapability TropicOperationalCapabilityType,
tnWanDescription SnmpAdminString
}
tnWanAlmProfName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION "."
::= { tnWanEntry 1 }
tnWanSyncEOprMode OBJECT-TYPE
SYNTAX INTEGER {
sync(1),
non-sync(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The Synchronous Ethernet Operation Mode. When in SYNC
mode, recovered clock of its input signal can be selected
as a reference clock to the system clock.When in NON-SYNC
mode, the recovered clock of its input signal shall
not be a candidate to system timing references."
DEFVAL { sync }
::= { tnWanEntry 2 }
tnWanSyncEOutgoingForceSsmTrans OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
act(2),
prc(3),
ssua(4),
ssub(5),
sec(6),
dnu(7),
stu(8),
prs(9),
st2(10),
sts3e(11),
st3(12),
none(13),
dus(14),
ePRTC(23),
pRTC(24),
ePRC(25),
eSEC(26)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The port SSM/Quality Level Transmission value.
The value can be:
In SDH mode - act, prc, ssua, ssub, sec, dnu,
ePRTC, PRTC, ePRC, eSEC, none.
In SONET mode - act, prs, stu, st2, st3e, st3,
ePRTC, PRTC, ePRC, dus, none."
DEFVAL { act }
::= { tnWanEntry 3 }
tnWanAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Wan administrative state. It may be used to
suppress the alarms or disable consequent
actions on the WAN entity."
DEFVAL { up }
::= { tnWanEntry 4 }
tnWanOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "operational state of WAN entity"
::= { tnWanEntry 5 }
tnWanStateQualifier OBJECT-TYPE
SYNTAX TropicStateQualifierType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the state qualifier (i.e., the
secondary state) of the WAN state."
::= { tnWanEntry 6 }
tnWanOperationalCapability OBJECT-TYPE
SYNTAX TropicOperationalCapabilityType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The partiallyEnabled(3) state means an abnormal
state."
::= { tnWanEntry 7 }
tnWanDescription OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Wan Description."
DEFVAL { "" }
::= { tnWanEntry 8 }
--------------------------------------------------------------------------------
-- Synchronous Ethernet Packetswitch Control Table
--------------------------------------------------------------------------------
tnSyncEPacketswitchControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnSyncPacketswitchControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of Sync-E Control attributes for a packetswitch.
This table provides the same functionality as
tnSyncEControlTable, but requires a switchid as an index"
::= { tnSyncEBasics 8 }
tnSyncEPacketswitchControlEntry OBJECT-TYPE
SYNTAX TnSyncPacketswitchControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "."
INDEX { tnSysSwitchId }
::= { tnSyncEPacketswitchControlTable 1 }
TnSyncPacketswitchControlEntry ::=
SEQUENCE {
tnSyncEPacketswitchControlEECEnable INTEGER
}
tnSyncEPacketswitchControlEECEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "enable - Synchronous Ethernet is supported for
the packetswitch and the synchronization
attributes can be configured.
disable - Synchronous Ethernet is not supported for
the packetswitch and the synchronization
attributes can not be configured."
DEFVAL { disable }
::= { tnSyncEPacketswitchControlEntry 1 }
--------------------------------------------------------------------------------
-- Conformance Group Definitions
--------------------------------------------------------------------------------
tnSyncEGroup OBJECT-GROUP
OBJECTS {
tnSyncESyncMsg,
tnSyncEActiveRef,
tnSyncEWTR,
tnSyncESwCmdLineRef,
tnSyncEClkModState,
tnSyncESystemQL,
tnSyncEQLDegradeThreshold,
tnSyncECurrentActiveLineRefFreqOff,
tnSyncEAlmProfName
}
STATUS current
DESCRIPTION "."
::= { tnSyncEGroups 1 }
tnSyncELineRefGroup OBJECT-GROUP
OBJECTS {
tnSyncELineRefAssignedPort,
tnSyncELineRefPriority,
tnSyncELineRefAdminState,
tnSyncELineRefOperState,
tnSyncELineLockOut,
tnSyncELineRefState,
tnSyncELineRefSwState,
tnSyncELineRefIncSSMMsg,
tnSyncELineRefIncSSMStatus,
tnSyncELineRefIncSSMSupp,
tnSyncELineRefProvQL,
tnSyncELineRefAssociatedPort,
tnSyncELineRefPriorityOfStationClock,
tnSyncELineRefLockOutOfStationClock,
tnSyncELineRefSwStateOfStationClock,
tnSyncELineRefCurrentFreqOff,
tnSyncELineRefAlmProfName,
tnSyncELineRefIncExtdQLTLVClockID,
tnSyncELineRefIncExtdQLTLVMixedClockType,
tnSyncELineRefIncExtdQLTLVPartialChain,
tnSyncELineRefIncExtdQLTLVNumeEEC,
tnSyncELineRefIncExtdQLTLVNumEEC,
tnSyncELineRefProvQLOfStationClock,
tnSyncELineRefIncSSMMsgOfStationClock,
tnSyncELineRefIncSSMStatusOfStationClock
}
STATUS current
DESCRIPTION "."
::= { tnSyncEGroups 2 }
tnSyncEControlGroup OBJECT-GROUP
OBJECTS {
tnSyncEControlEECEnable
}
STATUS current
DESCRIPTION "."
::= { tnSyncEGroups 3 }
tnSyncEPortGroup OBJECT-GROUP
OBJECTS {
tnSyncEOprMode,
tnSyncEOutgoingForceSsmTrans
}
STATUS current
DESCRIPTION "."
::= { tnSyncEGroups 4 }
tnSyncEStationClockGroup OBJECT-GROUP
OBJECTS {
tnSyncEStationClockSyncMsg,
tnSyncEStationClockActiveRef,
tnSyncEStationClockWTR,
tnSyncEStationClockSwCmdLineRef,
tnSyncEStationClockSystemQL,
tnSyncEStationClockQLThreshold,
tnSyncEStationClockOutSel,
tnSyncEStationClockAlmProfName
}
STATUS current
DESCRIPTION "."
::= { tnSyncEGroups 5 }
tnSyncEBITSPortGroup OBJECT-GROUP
OBJECTS {
tnSyncEBITSPortDirection,
tnSyncEBITSPortSignalType,
tnSyncEBITSPortSaBit,
tnSyncEBITSPortOutputSSMTrans,
tnSyncEBITSPortOutputAISMode,
tnSyncEBITSPortLineImpedance,
tnSyncEBITSPortLineCode,
tnSyncEBITSPortLbo,
tnSyncEBITSPortAlmProfName
}
STATUS current
DESCRIPTION "."
::= { tnSyncEGroups 6 }
tnWanGroup OBJECT-GROUP
OBJECTS {
tnWanAlmProfName,
tnWanSyncEOprMode,
tnWanSyncEOutgoingForceSsmTrans,
tnWanAdminStatus,
tnWanOperStatus,
tnWanStateQualifier,
tnWanOperationalCapability,
tnWanDescription
}
STATUS current
DESCRIPTION "."
::= { tnSyncEGroups 7 }
tnSyncEPacketswitchControlGroup OBJECT-GROUP
OBJECTS {
tnSyncEPacketswitchControlEECEnable
}
STATUS current
DESCRIPTION "."
::= { tnSyncEGroups 8 }
--------------------------------------------------------------------------------
-- Compliance Statements (mandatory)
--------------------------------------------------------------------------------
tnSyncECompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION "."
MODULE
MANDATORY-GROUPS {
tnSyncEGroup,
tnSyncELineRefGroup,
tnSyncEControlGroup,
tnSyncEPortGroup,
tnSyncEStationClockGroup,
tnSyncEBITSPortGroup,
tnWanGroup,
tnSyncEPacketswitchControlGroup
}
::= { tnSyncECompliances 1 }
END -- DEFINITION OF TROPIC-SYNCE-MIB