TROPIC-SYNCE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- (c) Copyright 2021 Nokia Networks. All rights reserved.
|
|
-- This software is the confidential and proprietary property of
|
|
-- Nokia and may only be used in accordance with the terms of the
|
|
-- license agreement provided with this software.
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY,
|
|
Unsigned32, Integer32 FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
|
|
TruthValue FROM SNMPv2-TC
|
|
ifIndex,
|
|
InterfaceIndexOrZero FROM IF-MIB
|
|
TropicStateQualifierType,
|
|
TropicOperationalCapabilityType,
|
|
NokiaSyncStatusMsgType FROM TROPIC-TC
|
|
tnShelfIndex FROM TROPIC-SHELF-MIB
|
|
tnSlotIndex FROM TROPIC-SLOT-MIB
|
|
tnPortModules, tnSyncEMIB FROM TROPIC-GLOBAL-REG
|
|
tnSysSwitchId FROM TROPIC-SYSTEM-MIB
|
|
AluWdmPtpClockIdentifier FROM TROPIC-PTP-MIB
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB;
|
|
|
|
tnSyncEMibModule MODULE-IDENTITY
|
|
LAST-UPDATED "202011201200Z"
|
|
ORGANIZATION "Nokia"
|
|
CONTACT-INFO "Nokia
|
|
Attn: Jeff Donnelly
|
|
600 Mountain Avenue
|
|
New Providence, NJ 07974
|
|
|
|
Phone: +1 732 221 6408
|
|
Email: jeff.donnelly@nokia.com"
|
|
|
|
DESCRIPTION "Synchronous Ethernet MIB attributes."
|
|
|
|
REVISION "202011201200Z"
|
|
DESCRIPTION "1) Added the following to tnSyncELineRefTable:
|
|
tnSyncELineRefProvQLOfStationClock
|
|
tnSyncELineRefIncSSMMsgOfStationClock
|
|
tnSyncELineRefIncSSMStatusOfStationClock.
|
|
2) Added the following to tnWanSyncEOutgoingForceSsmTrans:
|
|
ePRTC(23)
|
|
to
|
|
eSEC(26).
|
|
3) Updated DESCRIPTION of the following:
|
|
tnWanSyncEOutgoingForceSsmTrans."
|
|
|
|
REVISION "202011131200Z"
|
|
DESCRIPTION "1) Updated DESCRIPTION of the following:
|
|
tnSyncESystemQL
|
|
tnSyncEStationClockSystemQL
|
|
tnSyncEStationClockSyncMsg
|
|
tnSyncESyncMsg.
|
|
2) Changed SYNTAX of the following from TruthValue to NokiaSyncStatusMsgType:
|
|
tnSyncESyncMsg
|
|
tnSyncEStationClockSyncMsg."
|
|
|
|
REVISION "202011061200Z"
|
|
DESCRIPTION "1) Updated DESCRIPTION of the following:
|
|
tnSyncEQLDegradeThreshold
|
|
tnSyncEStationClockQLThreshold
|
|
tnSyncELineRefProvQL
|
|
tnSyncELineRefIncSSMMsg
|
|
tnSyncEOutgoingForceSsmTrans.
|
|
2) Added the following to tnSyncELineRefTable:
|
|
tnSyncELineRefIncExtdQLTLVClockID
|
|
tnSyncELineRefIncExtdQLTLVMixedClockType
|
|
tnSyncELineRefIncExtdQLTLVPartialChain
|
|
tnSyncELineRefIncExtdQLTLVNumeEEC
|
|
tnSyncELineRefIncExtdQLTLVNumEEC.
|
|
3) Added the following to tnSyncEOutgoingForceSsmTrans:
|
|
ePRTC(23)
|
|
to
|
|
eSEC(26)."
|
|
|
|
REVISION "202001101200Z"
|
|
DESCRIPTION "Added the following to tnSyncEBITSPortTable:
|
|
tnSyncEBITSPortAlmProfName."
|
|
|
|
REVISION "201909061200Z"
|
|
DESCRIPTION "1) Added the following to tnSyncETable:
|
|
tnSyncEAlmProfName.
|
|
2) Added the following to tnSyncELineRefTable:
|
|
tnSyncELineRefAlmProfName.
|
|
3) Added the following to tnSyncEStationClockTable:
|
|
tnSyncEStationClockAlmProfName."
|
|
|
|
REVISION "201809071200Z"
|
|
DESCRIPTION "Added the following to tnWanTable:
|
|
tnWanDescription."
|
|
|
|
REVISION "201804061200Z"
|
|
DESCRIPTION "Added notApplicable(0) to the following:
|
|
tnSyncEBITSPortSaBit
|
|
tnSyncEBITSPortOutputSSMTrans
|
|
tnSyncEBITSPortOutputAISMode."
|
|
|
|
REVISION "201802231200Z"
|
|
DESCRIPTION "Updated the contact info."
|
|
|
|
REVISION "201802161200Z"
|
|
DESCRIPTION "Added the following to tnSyncELineRefTable:
|
|
tnSyncELineRefCurrentFreqOff."
|
|
|
|
REVISION "201802091200Z"
|
|
DESCRIPTION "Added the following to tnSyncETable:
|
|
tnSyncEQLDegradeThreshold
|
|
tnSyncECurrentActiveLineRefFreqOff ."
|
|
|
|
REVISION "201709291200Z"
|
|
DESCRIPTION "Redefined tnWanSyncEOutgoingForceSsmTrans with the following values:
|
|
notApplicable(1),
|
|
to
|
|
dus(14)."
|
|
|
|
REVISION "201707071200Z"
|
|
DESCRIPTION "Fixed MIB compile issues."
|
|
|
|
REVISION "201706301200Z"
|
|
DESCRIPTION "Added the following table:
|
|
tnSyncEPacketswitchControlTable."
|
|
|
|
REVISION "201705261200Z"
|
|
DESCRIPTION "Added the following to tnSyncEBITSPortLineCode:
|
|
notApplicable(3)."
|
|
|
|
REVISION "201704211200Z"
|
|
DESCRIPTION "Modified MAX_ACCESS of tnSyncEBITSPortDirection from
|
|
read-only to read-create."
|
|
|
|
REVISION "201611291200Z"
|
|
DESCRIPTION "Added the following to tnWanTable:
|
|
tnWanOperStatus
|
|
tnWanStateQualifier
|
|
tnWanOperationalCapability."
|
|
|
|
REVISION "201611161200Z"
|
|
DESCRIPTION "Updated the contact info."
|
|
|
|
REVISION "201610191200Z"
|
|
DESCRIPTION "Added the following to tnSyncELineRefAssignedPort:
|
|
x7(38),
|
|
x8(39),
|
|
x9(40),
|
|
x10(41),
|
|
x11(42),
|
|
x12(43)."
|
|
|
|
REVISION "201608241200Z"
|
|
DESCRIPTION "1) Added the following tables:
|
|
tnWanTable.
|
|
2) Added the following to tnWanTable:
|
|
tnWanAlmProfName
|
|
tnWanSyncEOprMode
|
|
tnWanSyncEOutgoingForceSsmTrans
|
|
tnWanAdminStatus."
|
|
|
|
REVISION "201308261200Z"
|
|
DESCRIPTION "Updated description of the following:
|
|
tnSyncELineRefIncSSMSupp
|
|
tnSyncELineRefProvQL
|
|
tnSyncEBITSPortSignalType
|
|
tnSyncEBITSPortOutputSSMTrans
|
|
tnSyncEBITSPortOutputAISMode
|
|
tnSyncEBITSPortLineImpedance."
|
|
|
|
REVISION "201307121200Z"
|
|
DESCRIPTION "Added the following to tnSyncELineRefAssignedPort:
|
|
x5(32),
|
|
x6(33),
|
|
m1(34),
|
|
m2(35),
|
|
m3(36),
|
|
m4(37)."
|
|
|
|
REVISION "201306011200Z"
|
|
DESCRIPTION "1) Added the following to tnSyncEBITSPortTable:
|
|
tnSyncEBITSPortLineCode
|
|
tnSyncEBITSPortLbo.
|
|
2) Added the following to DESCRIPTION Of
|
|
tnSyncEBITSPortSignalType
|
|
DS1 SF(4)
|
|
DS1 ESF(5)."
|
|
|
|
REVISION "201212201200Z"
|
|
DESCRIPTION "Added the following to tnSyncEBITSPortTable:
|
|
tnSyncEBITSPortLineImpedance."
|
|
|
|
REVISION "201209011200Z"
|
|
DESCRIPTION "1) Added DEFVAL to the following:
|
|
tnSyncESyncMsg - false
|
|
tnSyncELineRefAssignedPort - none
|
|
tnSyncELineRefPriority - 0
|
|
tnSyncELineRefAdminState - up
|
|
tnSyncELineRefProvQL - 0.
|
|
2) Added the following to tnSyncEActiveRef:
|
|
lineRef3(6),
|
|
lineRef5(7).
|
|
3) Added the following to DESCRIPTION of tnSyncESwCmdLineRef:
|
|
5 - lineref4
|
|
6 - lineref5.
|
|
4) Added the following to tnSyncELineRefTable:
|
|
tnSyncELineRefAssociatedPort
|
|
tnSyncELineRefPriorityOfStationClock
|
|
tnSyncELineRefLockOutOfStationClock
|
|
tnSyncELineRefSwStateOfStationClock.
|
|
5) Added the following tables:
|
|
tnSyncEStationClockTable
|
|
tnSyncEBITSPortTable."
|
|
|
|
REVISION "201205081200Z"
|
|
DESCRIPTION "1) Added the following to tnSyncELineRefAssignedPort:
|
|
c22(25),
|
|
c23(26),
|
|
c24(27),
|
|
x1(28),
|
|
x2(29),
|
|
x3(30),
|
|
x4(31).
|
|
2) Added infinity time (999999) to tnSyncEWTR."
|
|
|
|
REVISION "201112211200Z"
|
|
DESCRIPTION "Modified descriptions of following:
|
|
tnSyncESystemQL
|
|
tnSyncELineRefIncSSMMsg
|
|
tnSyncELineRefProvQL."
|
|
|
|
REVISION "201108191200Z"
|
|
DESCRIPTION "1) Added the following to tnSyncELineRefAssignedPort:
|
|
c13(16)
|
|
c14(17)
|
|
c15(18)
|
|
c16(19)
|
|
c17(20)
|
|
c18(21)
|
|
c19(22)
|
|
c20(23)
|
|
c21(24).
|
|
2) Added the following to tnSyncEOutgoingForceSsmTrans:
|
|
dus(13).
|
|
3) Redefined enum values for the following attributes:
|
|
tnSyncELineRefOperState
|
|
tnSyncELineRefState.
|
|
4) Modified MAX_ACCESS of tnSyncELineLockOut from
|
|
read-create to read-only.
|
|
5) Modified DEFVAL of tnSyncELineRefIncSSMSupp.
|
|
6) Modified DESCRIPTION for the following attributes:
|
|
tnSyncELineRefIncSSMMsg
|
|
tnSyncELineRefProvQL."
|
|
|
|
REVISION "201107221200Z"
|
|
DESCRIPTION "1) Added SSM SyncE MIB tables:
|
|
tnSyncEControlTable
|
|
tnSyncEPortTable.
|
|
2) Redefined enum values for the following attributes:
|
|
tnSyncEActiveRef
|
|
tnSyncELineRefOperState.
|
|
3) Added the following to tnSyncETable:
|
|
tnSyncESystemQL.
|
|
4) Added the following to tnSyncELineRefTable:
|
|
tnSyncELineRefIncSSMMsg
|
|
tnSyncELineRefIncSSMStatus
|
|
tnSyncELineRefIncSSMSupp
|
|
tnSyncELineRefProvQL.
|
|
5) Modified DESCRIPTION of tnSyncESwCmdLineRef."
|
|
|
|
REVISION "201011301200Z"
|
|
DESCRIPTION "Changed description for the values of
|
|
tnSyncESwCmdLineRef."
|
|
|
|
REVISION "201011221200Z"
|
|
DESCRIPTION "Added tnSyncETable and tnSyncELineRefTable."
|
|
|
|
::= { tnPortModules 6 }
|
|
|
|
tnSyncEConf OBJECT IDENTIFIER ::= { tnSyncEMIB 1 }
|
|
tnSyncEGroups OBJECT IDENTIFIER ::= { tnSyncEConf 1 }
|
|
tnSyncECompliances OBJECT IDENTIFIER ::= { tnSyncEConf 2 }
|
|
tnSyncEObjs OBJECT IDENTIFIER ::= { tnSyncEMIB 2 }
|
|
tnSyncEBasics OBJECT IDENTIFIER ::= { tnSyncEObjs 1 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
-- Synchronous Ethernet Table
|
|
--------------------------------------------------------------------------------
|
|
tnSyncETable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnSyncEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of Sync-E attributes."
|
|
::= { tnSyncEBasics 1 }
|
|
|
|
tnSyncEEntry OBJECT-TYPE
|
|
SYNTAX TnSyncEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
INDEX { tnShelfIndex,
|
|
tnSlotIndex }
|
|
::= { tnSyncETable 1 }
|
|
|
|
TnSyncEntry ::=
|
|
SEQUENCE {
|
|
tnSyncESyncMsg NokiaSyncStatusMsgType,
|
|
tnSyncEActiveRef INTEGER,
|
|
tnSyncEWTR Unsigned32,
|
|
tnSyncESwCmdLineRef Unsigned32,
|
|
tnSyncEClkModState INTEGER,
|
|
tnSyncESystemQL Integer32,
|
|
tnSyncEQLDegradeThreshold Integer32,
|
|
tnSyncECurrentActiveLineRefFreqOff Integer32,
|
|
tnSyncEAlmProfName OCTET STRING
|
|
}
|
|
|
|
tnSyncESyncMsg OBJECT-TYPE
|
|
SYNTAX NokiaSyncStatusMsgType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Determines if the timing reference selection for system
|
|
timing uses Synchronization Status Message (SSM) Quality
|
|
Levels or Enhanced Quality Levels."
|
|
DEFVAL { false }
|
|
::= { tnSyncEEntry 1 }
|
|
|
|
tnSyncEActiveRef OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
lineRef0(2),
|
|
lineRef1(3),
|
|
lineRef2(4),
|
|
lineRef3(5),
|
|
lineRef4(6),
|
|
lineRef5(7)
|
|
}
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The ID of the association line reference."
|
|
DEFVAL { none }
|
|
::= { tnSyncEEntry 2 }
|
|
|
|
tnSyncEWTR OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The system timing WTR.
|
|
|
|
Current configurable range: 0 to 12, and 999999."
|
|
DEFVAL { 5 }
|
|
::= { tnSyncEEntry 3 }
|
|
|
|
tnSyncESwCmdLineRef OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The third byte represents the switch command:
|
|
1 - nocmd
|
|
2 - clear
|
|
3 - lockout
|
|
4 - forceswitch
|
|
5 - mannual
|
|
6 - auto
|
|
7 - clearlockout.
|
|
|
|
The last byte represents the line reference switch to:
|
|
0 - internal
|
|
1 - lineref0
|
|
2 - lineref1
|
|
3 - lineref2
|
|
4 - lineref3
|
|
5 - lineref4
|
|
6 - lineref5."
|
|
::= { tnSyncEEntry 4 }
|
|
|
|
tnSyncEClkModState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
locked(2),
|
|
autonomousHoldOver(3),
|
|
autonomousFreeRunning(4),
|
|
forcedFreeRunning(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The Sync-E clock mode state."
|
|
::= { tnSyncEEntry 5 }
|
|
|
|
tnSyncESystemQL OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The value of the system quality level (SSM), shown
|
|
in following:
|
|
31 - not applicable
|
|
|
|
When the NE is in SDH mode:
|
|
0 - quality unknown
|
|
1 - PRC
|
|
2 - SSU_A
|
|
3 - SSU_B
|
|
4 - SEC
|
|
5 - DNU
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
26 - eSEC.
|
|
|
|
When the NE is in SONET mode:
|
|
11 - PRS
|
|
12 - STU
|
|
13 - ST2
|
|
14 - TNC
|
|
15 - ST3E
|
|
16 - ST3
|
|
17 - SMC
|
|
18 - ST4
|
|
19 - DUS
|
|
20 - PNO
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC."
|
|
::= { tnSyncEEntry 6 }
|
|
|
|
tnSyncEQLDegradeThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The threshold value of SSM quality level degradation
|
|
for systme timing reference.
|
|
|
|
When the NE is in SDH mode:
|
|
1 - PRC
|
|
2 - SSU_A
|
|
3 - SSU_B
|
|
4 - SEC - Default
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
26 - eSEC.
|
|
|
|
When the NE is in SONET mode:
|
|
11 - PRS
|
|
12 - STU
|
|
13 - ST2
|
|
14 - TNC
|
|
15 - ST3E
|
|
16 - ST3 - Default
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC."
|
|
::= { tnSyncEEntry 7 }
|
|
|
|
tnSyncECurrentActiveLineRefFreqOff OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "ppb"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current frequency offset of the active timing reference."
|
|
::= { tnSyncEEntry 8 }
|
|
|
|
tnSyncEAlmProfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..40))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnSyncEEntry 9 }
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- Synchronous Ethernet Timing Line Reference Map Table
|
|
--------------------------------------------------------------------------------
|
|
tnSyncELineRefTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnSyncELineRefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of VTS map."
|
|
::= { tnSyncEBasics 2 }
|
|
|
|
tnSyncELineRefEntry OBJECT-TYPE
|
|
SYNTAX TnSyncELineRefEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
INDEX { tnShelfIndex,
|
|
tnSlotIndex,
|
|
tnSyncELineRefIndex }
|
|
::= { tnSyncELineRefTable 1 }
|
|
|
|
TnSyncELineRefEntry ::=
|
|
SEQUENCE {
|
|
tnSyncELineRefIndex Unsigned32,
|
|
tnSyncELineRefAssignedPort INTEGER,
|
|
tnSyncELineRefPriority Unsigned32,
|
|
tnSyncELineRefAdminState INTEGER,
|
|
tnSyncELineRefOperState INTEGER,
|
|
tnSyncELineLockOut TruthValue,
|
|
tnSyncELineRefState INTEGER,
|
|
tnSyncELineRefSwState INTEGER,
|
|
tnSyncELineRefIncSSMMsg Integer32,
|
|
tnSyncELineRefIncSSMStatus Integer32,
|
|
tnSyncELineRefIncSSMSupp INTEGER,
|
|
tnSyncELineRefProvQL Integer32,
|
|
tnSyncELineRefAssociatedPort InterfaceIndexOrZero,
|
|
tnSyncELineRefPriorityOfStationClock Unsigned32,
|
|
tnSyncELineRefLockOutOfStationClock TruthValue,
|
|
tnSyncELineRefSwStateOfStationClock INTEGER,
|
|
tnSyncELineRefCurrentFreqOff Integer32,
|
|
tnSyncELineRefAlmProfName OCTET STRING,
|
|
tnSyncELineRefIncExtdQLTLVClockID AluWdmPtpClockIdentifier,
|
|
tnSyncELineRefIncExtdQLTLVMixedClockType INTEGER,
|
|
tnSyncELineRefIncExtdQLTLVPartialChain INTEGER,
|
|
tnSyncELineRefIncExtdQLTLVNumeEEC Unsigned32,
|
|
tnSyncELineRefIncExtdQLTLVNumEEC Unsigned32,
|
|
tnSyncELineRefProvQLOfStationClock Integer32,
|
|
tnSyncELineRefIncSSMMsgOfStationClock Integer32,
|
|
tnSyncELineRefIncSSMStatusOfStationClock Integer32
|
|
}
|
|
|
|
tnSyncELineRefIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The ifIndex of the line reference table."
|
|
::= { tnSyncELineRefEntry 1 }
|
|
|
|
tnSyncELineRefAssignedPort OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
l1(2),
|
|
l2(3),
|
|
c1(4),
|
|
c2(5),
|
|
c3(6),
|
|
c4(7),
|
|
c5(8),
|
|
c6(9),
|
|
c7(10),
|
|
c8(11),
|
|
c9(12),
|
|
c10(13),
|
|
c11(14),
|
|
c12(15),
|
|
c13(16),
|
|
c14(17),
|
|
c15(18),
|
|
c16(19),
|
|
c17(20),
|
|
c18(21),
|
|
c19(22),
|
|
c20(23),
|
|
c21(24),
|
|
c22(25),
|
|
c23(26),
|
|
c24(27),
|
|
x1(28),
|
|
x2(29),
|
|
x3(30),
|
|
x4(31),
|
|
x5(32),
|
|
x6(33),
|
|
m1(34),
|
|
m2(35),
|
|
m3(36),
|
|
m4(37),
|
|
x7(38),
|
|
x8(39),
|
|
x9(40),
|
|
x10(41),
|
|
x11(42),
|
|
x12(43)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The assigned port for the line reference."
|
|
DEFVAL { none }
|
|
::= { tnSyncELineRefEntry 2 }
|
|
|
|
tnSyncELineRefPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..8)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Line reference priority.
|
|
|
|
Current configurable range: 0 to 8."
|
|
DEFVAL { 0 }
|
|
::= { tnSyncELineRefEntry 3 }
|
|
|
|
tnSyncELineRefAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The administrative state of the line reference."
|
|
DEFVAL { up }
|
|
::= { tnSyncELineRefEntry 4 }
|
|
|
|
tnSyncELineRefOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The operating state of the line reference."
|
|
::= { tnSyncELineRefEntry 5 }
|
|
|
|
tnSyncELineLockOut OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "If lock out line reference or not."
|
|
::= { tnSyncELineRefEntry 6 }
|
|
|
|
tnSyncELineRefState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAssigned(1),
|
|
normal(2),
|
|
signalFailure(3),
|
|
wtr(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The Sync-E line reference state."
|
|
::= { tnSyncELineRefEntry 7 }
|
|
|
|
tnSyncELineRefSwState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nocmd(1),
|
|
forced(2),
|
|
mansw(3),
|
|
lockout(4),
|
|
wtr(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The Sync-E line reference switch state."
|
|
::= { tnSyncELineRefEntry 8 }
|
|
|
|
tnSyncELineRefIncSSMMsg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the current value of incoming
|
|
QL on that port.
|
|
30 - unstable
|
|
31 - not applicable
|
|
|
|
When the NE works in SDH mode:
|
|
0 - Unknown
|
|
1 - PRC
|
|
2 - SSU_A
|
|
3 - SSU_B
|
|
4 - SEC
|
|
5 - DNU
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
26 - eSEC
|
|
|
|
When the NE works in SONET mode:
|
|
11 - PRS
|
|
12 - STU
|
|
13 - ST2
|
|
14 - TNC
|
|
15 - ST3E
|
|
16 - ST3
|
|
17 - SMC
|
|
18 - ST4
|
|
19 - DUS
|
|
20 - PNO
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
|
|
It's applicable only to the timing port with SSM
|
|
capabilities."
|
|
::= { tnSyncELineRefEntry 9 }
|
|
|
|
tnSyncELineRefIncSSMStatus OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the current status of incoming
|
|
QL on that port.
|
|
|
|
0: Valid
|
|
1: Invalid
|
|
2: Not Supported
|
|
3: Not Applicable
|
|
|
|
It's applicable only to the timing port with SSM
|
|
capabilities."
|
|
::= { tnSyncELineRefEntry 10 }
|
|
|
|
tnSyncELineRefIncSSMSupp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Enable or disable the line reference incoming QL processing."
|
|
DEFVAL { disable }
|
|
::= { tnSyncELineRefEntry 11 }
|
|
|
|
tnSyncELineRefProvQL OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Manually provisioned incoming SSM value for the line
|
|
reference. The value can be:
|
|
|
|
0 - AUTO
|
|
|
|
When the NE is in SDH mode:
|
|
1 - PRC
|
|
2 - SSU_A
|
|
3 - SSU_B
|
|
4 - SEC
|
|
5 - DNU
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
26 - eSEC
|
|
|
|
When the NE works in SONET mode:
|
|
11 - PRS
|
|
12 - STU
|
|
13 - ST2
|
|
14 - TNC
|
|
15 - ST3E
|
|
16 - ST3
|
|
17 - SMC
|
|
18 - ST4
|
|
19 - DUS
|
|
20 - PNO
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
|
|
Note: The parameter can be provisioned only when
|
|
SyncELineRefIncSSMSupp is enabled."
|
|
DEFVAL { 0 }
|
|
::= { tnSyncELineRefEntry 12 }
|
|
|
|
tnSyncELineRefAssociatedPort OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The associated physical port of the line
|
|
reference. This parameter replaces
|
|
tnSyncELineRefAssignedPort in order to support
|
|
assigning a line reference to a port in other
|
|
slots."
|
|
DEFVAL { 0 }
|
|
::= { tnSyncELineRefEntry 13 }
|
|
|
|
tnSyncELineRefPriorityOfStationClock OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..8)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Line reference priority for the output station
|
|
clock.
|
|
|
|
Current configurable range: 0 to 8."
|
|
DEFVAL { 0 }
|
|
::= { tnSyncELineRefEntry 14 }
|
|
|
|
tnSyncELineRefLockOutOfStationClock OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "If lock out the line reference or not for the
|
|
output station clock."
|
|
::= { tnSyncELineRefEntry 15 }
|
|
|
|
tnSyncELineRefSwStateOfStationClock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nocmd(1),
|
|
forced(2),
|
|
mansw(3),
|
|
lockout(4),
|
|
wtr(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The Sync-E line reference switch state of the
|
|
output station clock."
|
|
::= { tnSyncELineRefEntry 16 }
|
|
|
|
tnSyncELineRefCurrentFreqOff OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "ppb"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current frequency offset of the timing reference."
|
|
::= { tnSyncELineRefEntry 17 }
|
|
|
|
tnSyncELineRefAlmProfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..40))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnSyncELineRefEntry 18 }
|
|
|
|
tnSyncELineRefIncExtdQLTLVClockID OBJECT-TYPE
|
|
SYNTAX AluWdmPtpClockIdentifier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Incoming Extended QL TLV Clock ID."
|
|
::= { tnSyncELineRefEntry 19 }
|
|
|
|
tnSyncELineRefIncExtdQLTLVMixedClockType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEECFull(1),
|
|
eEECMixedEEC(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Incoming Extended QL TLV Mixed Clock Type Flag."
|
|
::= { tnSyncELineRefEntry 20 }
|
|
|
|
tnSyncELineRefIncExtdQLTLVPartialChain OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
completeChain(1),
|
|
partialChain(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Incoming Extended QL TLV Partial Chain Flag."
|
|
::= { tnSyncELineRefEntry 21 }
|
|
|
|
tnSyncELineRefIncExtdQLTLVNumeEEC OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Incoming Extended QL TLV Number of eEEC."
|
|
::= { tnSyncELineRefEntry 22 }
|
|
|
|
tnSyncELineRefIncExtdQLTLVNumEEC OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Incoming Extended QL TLV Number of EEC."
|
|
::= { tnSyncELineRefEntry 23 }
|
|
|
|
tnSyncELineRefProvQLOfStationClock OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Manually provisioned incoming SSM value
|
|
of the line reference output timing.
|
|
The value can be:
|
|
|
|
0 - AUTO
|
|
|
|
When the NE is in SDH mode:
|
|
1 - PRC
|
|
2 - SSU_A
|
|
3 - SSU_B
|
|
4 - SEC
|
|
5 - DNU
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
26 - eSEC
|
|
|
|
When the NE works in SONET mode:
|
|
11 - PRS
|
|
12 - STU
|
|
13 - ST2
|
|
14 - TNC
|
|
15 - ST3E
|
|
16 - ST3
|
|
17 - SMC
|
|
18 - ST4
|
|
19 - DUS
|
|
20 - PNO
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
|
|
Note: The parameter can be provisioned only when
|
|
SyncELineRefIncSSMSupp is enabled."
|
|
DEFVAL { 0 }
|
|
::= { tnSyncELineRefEntry 24 }
|
|
|
|
tnSyncELineRefIncSSMMsgOfStationClock OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the current value of incoming
|
|
QL for output timing on that port.
|
|
30 - unstable
|
|
31 - not applicable
|
|
|
|
When the NE works in SDH mode:
|
|
0 - Unknown
|
|
1 - PRC
|
|
2 - SSU_A
|
|
3 - SSU_B
|
|
4 - SEC
|
|
5 - DNU
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
26 - eSEC
|
|
|
|
When the NE works in SONET mode:
|
|
11 - PRS
|
|
12 - STU
|
|
13 - ST2
|
|
14 - TNC
|
|
15 - ST3E
|
|
16 - ST3
|
|
17 - SMC
|
|
18 - ST4
|
|
19 - DUS
|
|
20 - PNO
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
|
|
It's applicable only to the timing port with SSM
|
|
capabilities."
|
|
::= { tnSyncELineRefEntry 25 }
|
|
|
|
tnSyncELineRefIncSSMStatusOfStationClock OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the current status of incoming
|
|
QL on that port for output timing.
|
|
|
|
0: Valid
|
|
1: Invalid
|
|
2: Not Supported
|
|
3: Not Applicable
|
|
|
|
It's applicable only to the timing port with SSM
|
|
capabilities."
|
|
::= { tnSyncELineRefEntry 26 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
-- Synchronous Ethernet Control Table
|
|
--------------------------------------------------------------------------------
|
|
tnSyncEControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnSyncControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of Sync-E Control attributes."
|
|
::= { tnSyncEBasics 3 }
|
|
|
|
tnSyncEControlEntry OBJECT-TYPE
|
|
SYNTAX TnSyncControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
INDEX { tnShelfIndex,
|
|
tnSlotIndex }
|
|
::= { tnSyncEControlTable 1 }
|
|
|
|
TnSyncControlEntry ::=
|
|
SEQUENCE {
|
|
tnSyncEControlEECEnable INTEGER
|
|
}
|
|
|
|
tnSyncEControlEECEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "enable - The Synchronous Ethernet is supported
|
|
for the pack and the synchronization
|
|
attributes can be configured.
|
|
disable - The Synchronous Ethernet is not supported
|
|
for the pack and the synchronization
|
|
attributes can not be configured."
|
|
DEFVAL { disable }
|
|
::= { tnSyncEControlEntry 1 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
-- Synchronous Ethernet Port Table
|
|
--------------------------------------------------------------------------------
|
|
tnSyncEPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnSyncPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of Sync-E Port attributes."
|
|
::= { tnSyncEBasics 4 }
|
|
|
|
tnSyncEPortEntry OBJECT-TYPE
|
|
SYNTAX TnSyncPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
INDEX { ifIndex }
|
|
::= { tnSyncEPortTable 1 }
|
|
|
|
TnSyncPortEntry ::=
|
|
SEQUENCE {
|
|
tnSyncEOprMode INTEGER,
|
|
tnSyncEOutgoingForceSsmTrans INTEGER
|
|
}
|
|
|
|
tnSyncEOprMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sync(1),
|
|
non-sync(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The port Synchronous Ethernet Operation Mode. When
|
|
the port is in SYNC mode, recovered clock of its
|
|
input signal can be selected as a reference clock
|
|
to the system clock. When the port is in NON-SYNC
|
|
mode, the recovered clock of its input signal shall
|
|
not be a candidate to system timing references."
|
|
DEFVAL { sync }
|
|
::= { tnSyncEPortEntry 1 }
|
|
|
|
tnSyncEOutgoingForceSsmTrans OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
act(1),
|
|
prc(2),
|
|
ssua(3),
|
|
ssub(4),
|
|
sec(5),
|
|
dnu(6),
|
|
stu(7),
|
|
prs(8),
|
|
st2(9),
|
|
sts3e(10),
|
|
st3(11),
|
|
none(12),
|
|
dus(13),
|
|
ePRTC(23),
|
|
pRTC(24),
|
|
ePRC(25),
|
|
eSEC(26)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The port SSM/Quality Level Transmission value.
|
|
The value can be:
|
|
In SDH mode - act, prc, ssua, ssub, sec, dnu,
|
|
ePRTC, PRTC, ePRC, eSEC, none;
|
|
In sonet mode - act, stu, prs, st2, sts3e, st3,
|
|
ePRTC, PRTC, ePRC, dus, none."
|
|
DEFVAL { act }
|
|
::= { tnSyncEPortEntry 2 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
-- Synchronous Ethernet Station Clock Table
|
|
--------------------------------------------------------------------------------
|
|
tnSyncEStationClockTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnSyncEStationClockEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of Sync-E station clock attributes."
|
|
::= { tnSyncEBasics 5 }
|
|
|
|
tnSyncEStationClockEntry OBJECT-TYPE
|
|
SYNTAX TnSyncEStationClockEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
INDEX { tnShelfIndex,
|
|
tnSlotIndex }
|
|
::= { tnSyncEStationClockTable 1 }
|
|
|
|
TnSyncEStationClockEntry ::=
|
|
SEQUENCE {
|
|
tnSyncEStationClockSyncMsg NokiaSyncStatusMsgType,
|
|
tnSyncEStationClockActiveRef INTEGER,
|
|
tnSyncEStationClockWTR Unsigned32,
|
|
tnSyncEStationClockSwCmdLineRef Unsigned32,
|
|
tnSyncEStationClockSystemQL Integer32,
|
|
tnSyncEStationClockQLThreshold Integer32,
|
|
tnSyncEStationClockOutSel INTEGER,
|
|
tnSyncEStationClockAlmProfName OCTET STRING
|
|
}
|
|
|
|
tnSyncEStationClockSyncMsg OBJECT-TYPE
|
|
SYNTAX NokiaSyncStatusMsgType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Determines if the timing reference selection for
|
|
station clock timing uses Synchronization Status Message
|
|
(SSM) Quality Levels or Enhanced Quality Levels."
|
|
DEFVAL { false }
|
|
::= { tnSyncEStationClockEntry 1 }
|
|
|
|
tnSyncEStationClockActiveRef OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
lineRef0(2),
|
|
lineRef1(3),
|
|
lineRef2(4),
|
|
lineRef3(5),
|
|
lineRef4(6),
|
|
lineRef5(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The ID of the association line reference."
|
|
DEFVAL { none }
|
|
::= { tnSyncEStationClockEntry 2 }
|
|
|
|
tnSyncEStationClockWTR OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The station clock timing WTR.
|
|
|
|
Current configurable range: 0 to 12, and 999999."
|
|
DEFVAL { 5 }
|
|
::= { tnSyncEStationClockEntry 3 }
|
|
|
|
tnSyncEStationClockSwCmdLineRef OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The third byte represents the switch command:
|
|
1 - nocmd
|
|
2 - clear
|
|
3 - lockout
|
|
4 - forceswitch
|
|
5 - mannual
|
|
6 - auto
|
|
7 - clearlockout.
|
|
|
|
The last byte represents the line reference switch to:
|
|
0 - internal
|
|
1 - lineref0
|
|
2 - lineref1
|
|
3 - lineref2
|
|
4 - lineref3
|
|
5 - lineref4
|
|
6 - lineref5."
|
|
::= { tnSyncEStationClockEntry 4 }
|
|
|
|
tnSyncEStationClockSystemQL OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The value of the system quality level (SSM) for
|
|
the output timing clock, shown in following:
|
|
31 - not applicable
|
|
|
|
When the NE is in SDH mode:
|
|
0 - quality unknown
|
|
1 - PRC
|
|
2 - SSU_A
|
|
3 - SSU_B
|
|
4 - SEC
|
|
5 - DNU
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
26 - eSEC.
|
|
|
|
When the NE is in SONET mode:
|
|
11 - PRS
|
|
12 - STU
|
|
13 - ST2
|
|
14 - TNC
|
|
15 - ST3E
|
|
16 - ST3
|
|
17 - SMC
|
|
18 - ST4
|
|
19 - DUS
|
|
20 - PNO
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC."
|
|
::= { tnSyncEStationClockEntry 5}
|
|
|
|
tnSyncEStationClockQLThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Specifies the threshold value for the quality
|
|
level i.e., SSM value for squelching the output
|
|
towards timing output. If the quality value of
|
|
the current selected signal for the output is
|
|
below the threshold value, the output will be
|
|
squelched. The squelching can be disabled by
|
|
means of using the value DNU or DUS.
|
|
|
|
When the NE is in SDH mode:
|
|
1 - PRC
|
|
2 - SSU_A
|
|
3 - SSU_B
|
|
4 - SEC
|
|
5 - DNU
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC
|
|
26 - eSEC.
|
|
|
|
When the NE is in SONET mode:
|
|
11 - PRS
|
|
12 - STU
|
|
13 - ST2
|
|
14 - TNC
|
|
15 - ST3E
|
|
16 - ST3
|
|
17 - SMC
|
|
18 - ST4
|
|
19 - DUS
|
|
23 - ePRTC
|
|
24 - PRTC
|
|
25 - ePRC.
|
|
|
|
Default value:
|
|
SEC - for node working in SDH mode
|
|
ST3 - for node working in SONET mode"
|
|
DEFVAL { 4 }
|
|
::= { tnSyncEStationClockEntry 6}
|
|
|
|
tnSyncEStationClockOutSel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
outtim(1),
|
|
setg(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Specifies which signal is selected for the output
|
|
station clock:
|
|
OUTTIM - Output is selected from output timing
|
|
selection process
|
|
SETG - Output is selected from system internal
|
|
timing The ID of the association line
|
|
reference."
|
|
DEFVAL { outtim }
|
|
::= { tnSyncEStationClockEntry 7 }
|
|
|
|
tnSyncEStationClockAlmProfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..40))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnSyncEStationClockEntry 8 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
-- Synchronous Ethernet BITS Port Table
|
|
--------------------------------------------------------------------------------
|
|
tnSyncEBITSPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnSyncEBITSPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of BITS port attributes."
|
|
::= { tnSyncEBasics 6 }
|
|
|
|
tnSyncEBITSPortEntry OBJECT-TYPE
|
|
SYNTAX TnSyncEBITSPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
INDEX { ifIndex }
|
|
::= { tnSyncEBITSPortTable 1 }
|
|
|
|
TnSyncEBITSPortEntry ::=
|
|
SEQUENCE {
|
|
tnSyncEBITSPortDirection INTEGER,
|
|
tnSyncEBITSPortSignalType Integer32,
|
|
tnSyncEBITSPortSaBit INTEGER,
|
|
tnSyncEBITSPortOutputSSMTrans INTEGER,
|
|
tnSyncEBITSPortOutputAISMode INTEGER,
|
|
tnSyncEBITSPortLineImpedance INTEGER,
|
|
tnSyncEBITSPortLineCode INTEGER,
|
|
tnSyncEBITSPortLbo INTEGER,
|
|
tnSyncEBITSPortAlmProfName OCTET STRING
|
|
}
|
|
|
|
tnSyncEBITSPortDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(1),
|
|
output(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Indicate the direction of the BITS port."
|
|
::= { tnSyncEBITSPortEntry 1 }
|
|
|
|
tnSyncEBITSPortSignalType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Specify the signal type for the BITS interface:
|
|
0 - 2MHz
|
|
1 - unframed E1
|
|
2 - framed E1 without SSM
|
|
3 - framed E1 with SSM
|
|
4 - DS1 SF
|
|
5 - DS1 ESF.
|
|
|
|
In SDH mode, 2MHz and E1 signal types are valid
|
|
and 2MHz is the default value. In SONET mode,
|
|
only the DS1 signal types are valid and DS1 SF
|
|
is the default value."
|
|
DEFVAL { 0 }
|
|
::= { tnSyncEBITSPortEntry 2 }
|
|
|
|
tnSyncEBITSPortSaBit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(0),
|
|
sa4 (1),
|
|
sa5 (2),
|
|
sa6 (3),
|
|
sa7 (4),
|
|
sa8 (5)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Specifies the Sa bit location used to carry the
|
|
SSM information. This parameter is only
|
|
applicable when tnSyncEBITSPortSignalType = 3
|
|
(framed E1 with SSM)"
|
|
DEFVAL { sa4 }
|
|
::= { tnSyncEBITSPortEntry 3 }
|
|
|
|
tnSyncEBITSPortOutputSSMTrans OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(0),
|
|
act(1),
|
|
prc(2),
|
|
ssua(3),
|
|
ssub(4),
|
|
sec(5),
|
|
dnu(6),
|
|
stu(7),
|
|
prs(8),
|
|
st2(9),
|
|
sts3e(10),
|
|
st3(11),
|
|
none(12),
|
|
dus(13)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The port SSM/Quality Level Transmission value.
|
|
The value can be:
|
|
In SDH mode - act, prc, ssua, ssub, sec,
|
|
dnu, none;
|
|
In sonet mode - act, stu, prs, st2, sts3e,
|
|
st3, dus, none.
|
|
Restriction: The parameter is only applicable
|
|
when tnSyncEBITSPortDirection = output and
|
|
tnSyncEBITSPortSignalType = 3 (framed E1 with
|
|
SSM)or 5 (DS1 ESF)."
|
|
DEFVAL { act }
|
|
::= { tnSyncEBITSPortEntry 4 }
|
|
|
|
tnSyncEBITSPortOutputAISMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(0),
|
|
aismode(1),
|
|
qlmode(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Specifies which signal is inserted for the timing
|
|
output port if the output signal is squelched.
|
|
The parameter is only applicable for output port
|
|
types supporting SSM.
|
|
AISMODE - AIS signal is inserted.
|
|
QLMODE - DUS is inserted as SSM; output is
|
|
squelched.
|
|
Restriction: The parameter is only applicable
|
|
when tnSyncEBITSPortDirection = output and
|
|
tnSyncEBITSPortSignalType = 3 (framed E1 with SSM)
|
|
or 5 (DS1 ESF)."
|
|
DEFVAL { qlmode }
|
|
::= { tnSyncEBITSPortEntry 5 }
|
|
|
|
tnSyncEBITSPortLineImpedance OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
imp75ohms(1),
|
|
imp120ohms(2),
|
|
imp100ohms(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Nominal line impedance.
|
|
When in SDH mode, imp75ohms or imp120ohms could
|
|
be used and the default is imp120ohms. When in
|
|
ONET mode, imp100ohms could be used and the default
|
|
is imp100ohms."
|
|
DEFVAL { imp120ohms }
|
|
::= { tnSyncEBITSPortEntry 6 }
|
|
|
|
tnSyncEBITSPortLineCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
b8zs(1),
|
|
ami(2),
|
|
notApplicable(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Line code. This attribute is applicable when
|
|
tnSyncEBITSPortSignalType is DS1 SF or DS1 ESF."
|
|
DEFVAL { b8zs }
|
|
::= { tnSyncEBITSPortEntry 7 }
|
|
|
|
tnSyncEBITSPortLbo OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lbo(1),
|
|
lbo1(2),
|
|
lbo2(3),
|
|
lbo3(4),
|
|
lbo4(5),
|
|
lbo5(6)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Line equalization value for the BITS output port,
|
|
taking one of the following values:
|
|
- lbo: no compensation
|
|
- lbo1: 0 to 133 feet
|
|
- lbo2: 133 to 266 feet
|
|
- lbo3: 267 to 399 feet
|
|
- lbo4: 400 to 533 feet
|
|
- lbo5: 534 to 655 feet
|
|
|
|
This attribute is applicable when tnSyncEBITSPortSignalType
|
|
is DS1 SF or DS1 ESF."
|
|
DEFVAL { lbo1 }
|
|
::= { tnSyncEBITSPortEntry 8 }
|
|
|
|
tnSyncEBITSPortAlmProfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..40))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Alarm profile for BITs port"
|
|
::= { tnSyncEBITSPortEntry 9}
|
|
|
|
--------------------------------------------------------------------------------
|
|
-- Wan Table
|
|
--------------------------------------------------------------------------------
|
|
tnWanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnWanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of Wan attributes."
|
|
::= { tnSyncEBasics 7 }
|
|
|
|
tnWanEntry OBJECT-TYPE
|
|
SYNTAX TnWanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
INDEX { ifIndex }
|
|
::= { tnWanTable 1 }
|
|
|
|
TnWanEntry ::=
|
|
SEQUENCE {
|
|
tnWanAlmProfName OCTET STRING,
|
|
tnWanSyncEOprMode INTEGER,
|
|
tnWanSyncEOutgoingForceSsmTrans INTEGER,
|
|
tnWanAdminStatus INTEGER,
|
|
tnWanOperStatus INTEGER,
|
|
tnWanStateQualifier TropicStateQualifierType,
|
|
tnWanOperationalCapability TropicOperationalCapabilityType,
|
|
tnWanDescription SnmpAdminString
|
|
|
|
}
|
|
tnWanAlmProfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnWanEntry 1 }
|
|
|
|
tnWanSyncEOprMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sync(1),
|
|
non-sync(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The Synchronous Ethernet Operation Mode. When in SYNC
|
|
mode, recovered clock of its input signal can be selected
|
|
as a reference clock to the system clock.When in NON-SYNC
|
|
mode, the recovered clock of its input signal shall
|
|
not be a candidate to system timing references."
|
|
DEFVAL { sync }
|
|
::= { tnWanEntry 2 }
|
|
|
|
tnWanSyncEOutgoingForceSsmTrans OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
act(2),
|
|
prc(3),
|
|
ssua(4),
|
|
ssub(5),
|
|
sec(6),
|
|
dnu(7),
|
|
stu(8),
|
|
prs(9),
|
|
st2(10),
|
|
sts3e(11),
|
|
st3(12),
|
|
none(13),
|
|
dus(14),
|
|
ePRTC(23),
|
|
pRTC(24),
|
|
ePRC(25),
|
|
eSEC(26)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The port SSM/Quality Level Transmission value.
|
|
The value can be:
|
|
In SDH mode - act, prc, ssua, ssub, sec, dnu,
|
|
ePRTC, PRTC, ePRC, eSEC, none.
|
|
In SONET mode - act, prs, stu, st2, st3e, st3,
|
|
ePRTC, PRTC, ePRC, dus, none."
|
|
DEFVAL { act }
|
|
::= { tnWanEntry 3 }
|
|
|
|
tnWanAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Wan administrative state. It may be used to
|
|
suppress the alarms or disable consequent
|
|
actions on the WAN entity."
|
|
DEFVAL { up }
|
|
::= { tnWanEntry 4 }
|
|
|
|
tnWanOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "operational state of WAN entity"
|
|
::= { tnWanEntry 5 }
|
|
|
|
tnWanStateQualifier OBJECT-TYPE
|
|
SYNTAX TropicStateQualifierType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the state qualifier (i.e., the
|
|
secondary state) of the WAN state."
|
|
::= { tnWanEntry 6 }
|
|
|
|
tnWanOperationalCapability OBJECT-TYPE
|
|
SYNTAX TropicOperationalCapabilityType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The partiallyEnabled(3) state means an abnormal
|
|
state."
|
|
::= { tnWanEntry 7 }
|
|
|
|
tnWanDescription OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(0..255))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Wan Description."
|
|
DEFVAL { "" }
|
|
::= { tnWanEntry 8 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
-- Synchronous Ethernet Packetswitch Control Table
|
|
--------------------------------------------------------------------------------
|
|
tnSyncEPacketswitchControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TnSyncPacketswitchControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of Sync-E Control attributes for a packetswitch.
|
|
This table provides the same functionality as
|
|
tnSyncEControlTable, but requires a switchid as an index"
|
|
::= { tnSyncEBasics 8 }
|
|
|
|
tnSyncEPacketswitchControlEntry OBJECT-TYPE
|
|
SYNTAX TnSyncPacketswitchControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
INDEX { tnSysSwitchId }
|
|
::= { tnSyncEPacketswitchControlTable 1 }
|
|
|
|
TnSyncPacketswitchControlEntry ::=
|
|
SEQUENCE {
|
|
tnSyncEPacketswitchControlEECEnable INTEGER
|
|
}
|
|
|
|
tnSyncEPacketswitchControlEECEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "enable - Synchronous Ethernet is supported for
|
|
the packetswitch and the synchronization
|
|
attributes can be configured.
|
|
disable - Synchronous Ethernet is not supported for
|
|
the packetswitch and the synchronization
|
|
attributes can not be configured."
|
|
DEFVAL { disable }
|
|
::= { tnSyncEPacketswitchControlEntry 1 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
-- Conformance Group Definitions
|
|
--------------------------------------------------------------------------------
|
|
tnSyncEGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tnSyncESyncMsg,
|
|
tnSyncEActiveRef,
|
|
tnSyncEWTR,
|
|
tnSyncESwCmdLineRef,
|
|
tnSyncEClkModState,
|
|
tnSyncESystemQL,
|
|
tnSyncEQLDegradeThreshold,
|
|
tnSyncECurrentActiveLineRefFreqOff,
|
|
tnSyncEAlmProfName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnSyncEGroups 1 }
|
|
|
|
tnSyncELineRefGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tnSyncELineRefAssignedPort,
|
|
tnSyncELineRefPriority,
|
|
tnSyncELineRefAdminState,
|
|
tnSyncELineRefOperState,
|
|
tnSyncELineLockOut,
|
|
tnSyncELineRefState,
|
|
tnSyncELineRefSwState,
|
|
tnSyncELineRefIncSSMMsg,
|
|
tnSyncELineRefIncSSMStatus,
|
|
tnSyncELineRefIncSSMSupp,
|
|
tnSyncELineRefProvQL,
|
|
tnSyncELineRefAssociatedPort,
|
|
tnSyncELineRefPriorityOfStationClock,
|
|
tnSyncELineRefLockOutOfStationClock,
|
|
tnSyncELineRefSwStateOfStationClock,
|
|
tnSyncELineRefCurrentFreqOff,
|
|
tnSyncELineRefAlmProfName,
|
|
tnSyncELineRefIncExtdQLTLVClockID,
|
|
tnSyncELineRefIncExtdQLTLVMixedClockType,
|
|
tnSyncELineRefIncExtdQLTLVPartialChain,
|
|
tnSyncELineRefIncExtdQLTLVNumeEEC,
|
|
tnSyncELineRefIncExtdQLTLVNumEEC,
|
|
tnSyncELineRefProvQLOfStationClock,
|
|
tnSyncELineRefIncSSMMsgOfStationClock,
|
|
tnSyncELineRefIncSSMStatusOfStationClock
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnSyncEGroups 2 }
|
|
|
|
tnSyncEControlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tnSyncEControlEECEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnSyncEGroups 3 }
|
|
|
|
tnSyncEPortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tnSyncEOprMode,
|
|
tnSyncEOutgoingForceSsmTrans
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnSyncEGroups 4 }
|
|
|
|
tnSyncEStationClockGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tnSyncEStationClockSyncMsg,
|
|
tnSyncEStationClockActiveRef,
|
|
tnSyncEStationClockWTR,
|
|
tnSyncEStationClockSwCmdLineRef,
|
|
tnSyncEStationClockSystemQL,
|
|
tnSyncEStationClockQLThreshold,
|
|
tnSyncEStationClockOutSel,
|
|
tnSyncEStationClockAlmProfName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnSyncEGroups 5 }
|
|
|
|
tnSyncEBITSPortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tnSyncEBITSPortDirection,
|
|
tnSyncEBITSPortSignalType,
|
|
tnSyncEBITSPortSaBit,
|
|
tnSyncEBITSPortOutputSSMTrans,
|
|
tnSyncEBITSPortOutputAISMode,
|
|
tnSyncEBITSPortLineImpedance,
|
|
tnSyncEBITSPortLineCode,
|
|
tnSyncEBITSPortLbo,
|
|
tnSyncEBITSPortAlmProfName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnSyncEGroups 6 }
|
|
|
|
tnWanGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tnWanAlmProfName,
|
|
tnWanSyncEOprMode,
|
|
tnWanSyncEOutgoingForceSsmTrans,
|
|
tnWanAdminStatus,
|
|
tnWanOperStatus,
|
|
tnWanStateQualifier,
|
|
tnWanOperationalCapability,
|
|
tnWanDescription
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnSyncEGroups 7 }
|
|
|
|
tnSyncEPacketswitchControlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tnSyncEPacketswitchControlEECEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
::= { tnSyncEGroups 8 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
-- Compliance Statements (mandatory)
|
|
--------------------------------------------------------------------------------
|
|
tnSyncECompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION "."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tnSyncEGroup,
|
|
tnSyncELineRefGroup,
|
|
tnSyncEControlGroup,
|
|
tnSyncEPortGroup,
|
|
tnSyncEStationClockGroup,
|
|
tnSyncEBITSPortGroup,
|
|
tnWanGroup,
|
|
tnSyncEPacketswitchControlGroup
|
|
}
|
|
::= { tnSyncECompliances 1 }
|
|
|
|
END -- DEFINITION OF TROPIC-SYNCE-MIB
|