TROPIC-SYNCE-MIB DEFINITIONS ::= BEGIN -- (c) Copyright 2021 Nokia Networks. All rights reserved. -- This software is the confidential and proprietary property of -- Nokia and may only be used in accordance with the terms of the -- license agreement provided with this software. IMPORTS OBJECT-TYPE, MODULE-IDENTITY, Unsigned32, Integer32 FROM SNMPv2-SMI MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF TruthValue FROM SNMPv2-TC ifIndex, InterfaceIndexOrZero FROM IF-MIB TropicStateQualifierType, TropicOperationalCapabilityType, NokiaSyncStatusMsgType FROM TROPIC-TC tnShelfIndex FROM TROPIC-SHELF-MIB tnSlotIndex FROM TROPIC-SLOT-MIB tnPortModules, tnSyncEMIB FROM TROPIC-GLOBAL-REG tnSysSwitchId FROM TROPIC-SYSTEM-MIB AluWdmPtpClockIdentifier FROM TROPIC-PTP-MIB SnmpAdminString FROM SNMP-FRAMEWORK-MIB; tnSyncEMibModule MODULE-IDENTITY LAST-UPDATED "202011201200Z" ORGANIZATION "Nokia" CONTACT-INFO "Nokia Attn: Jeff Donnelly 600 Mountain Avenue New Providence, NJ 07974 Phone: +1 732 221 6408 Email: jeff.donnelly@nokia.com" DESCRIPTION "Synchronous Ethernet MIB attributes." REVISION "202011201200Z" DESCRIPTION "1) Added the following to tnSyncELineRefTable: tnSyncELineRefProvQLOfStationClock tnSyncELineRefIncSSMMsgOfStationClock tnSyncELineRefIncSSMStatusOfStationClock. 2) Added the following to tnWanSyncEOutgoingForceSsmTrans: ePRTC(23) to eSEC(26). 3) Updated DESCRIPTION of the following: tnWanSyncEOutgoingForceSsmTrans." REVISION "202011131200Z" DESCRIPTION "1) Updated DESCRIPTION of the following: tnSyncESystemQL tnSyncEStationClockSystemQL tnSyncEStationClockSyncMsg tnSyncESyncMsg. 2) Changed SYNTAX of the following from TruthValue to NokiaSyncStatusMsgType: tnSyncESyncMsg tnSyncEStationClockSyncMsg." REVISION "202011061200Z" DESCRIPTION "1) Updated DESCRIPTION of the following: tnSyncEQLDegradeThreshold tnSyncEStationClockQLThreshold tnSyncELineRefProvQL tnSyncELineRefIncSSMMsg tnSyncEOutgoingForceSsmTrans. 2) Added the following to tnSyncELineRefTable: tnSyncELineRefIncExtdQLTLVClockID tnSyncELineRefIncExtdQLTLVMixedClockType tnSyncELineRefIncExtdQLTLVPartialChain tnSyncELineRefIncExtdQLTLVNumeEEC tnSyncELineRefIncExtdQLTLVNumEEC. 3) Added the following to tnSyncEOutgoingForceSsmTrans: ePRTC(23) to eSEC(26)." REVISION "202001101200Z" DESCRIPTION "Added the following to tnSyncEBITSPortTable: tnSyncEBITSPortAlmProfName." REVISION "201909061200Z" DESCRIPTION "1) Added the following to tnSyncETable: tnSyncEAlmProfName. 2) Added the following to tnSyncELineRefTable: tnSyncELineRefAlmProfName. 3) Added the following to tnSyncEStationClockTable: tnSyncEStationClockAlmProfName." REVISION "201809071200Z" DESCRIPTION "Added the following to tnWanTable: tnWanDescription." REVISION "201804061200Z" DESCRIPTION "Added notApplicable(0) to the following: tnSyncEBITSPortSaBit tnSyncEBITSPortOutputSSMTrans tnSyncEBITSPortOutputAISMode." REVISION "201802231200Z" DESCRIPTION "Updated the contact info." REVISION "201802161200Z" DESCRIPTION "Added the following to tnSyncELineRefTable: tnSyncELineRefCurrentFreqOff." REVISION "201802091200Z" DESCRIPTION "Added the following to tnSyncETable: tnSyncEQLDegradeThreshold tnSyncECurrentActiveLineRefFreqOff ." REVISION "201709291200Z" DESCRIPTION "Redefined tnWanSyncEOutgoingForceSsmTrans with the following values: notApplicable(1), to dus(14)." REVISION "201707071200Z" DESCRIPTION "Fixed MIB compile issues." REVISION "201706301200Z" DESCRIPTION "Added the following table: tnSyncEPacketswitchControlTable." REVISION "201705261200Z" DESCRIPTION "Added the following to tnSyncEBITSPortLineCode: notApplicable(3)." REVISION "201704211200Z" DESCRIPTION "Modified MAX_ACCESS of tnSyncEBITSPortDirection from read-only to read-create." REVISION "201611291200Z" DESCRIPTION "Added the following to tnWanTable: tnWanOperStatus tnWanStateQualifier tnWanOperationalCapability." REVISION "201611161200Z" DESCRIPTION "Updated the contact info." REVISION "201610191200Z" DESCRIPTION "Added the following to tnSyncELineRefAssignedPort: x7(38), x8(39), x9(40), x10(41), x11(42), x12(43)." REVISION "201608241200Z" DESCRIPTION "1) Added the following tables: tnWanTable. 2) Added the following to tnWanTable: tnWanAlmProfName tnWanSyncEOprMode tnWanSyncEOutgoingForceSsmTrans tnWanAdminStatus." REVISION "201308261200Z" DESCRIPTION "Updated description of the following: tnSyncELineRefIncSSMSupp tnSyncELineRefProvQL tnSyncEBITSPortSignalType tnSyncEBITSPortOutputSSMTrans tnSyncEBITSPortOutputAISMode tnSyncEBITSPortLineImpedance." REVISION "201307121200Z" DESCRIPTION "Added the following to tnSyncELineRefAssignedPort: x5(32), x6(33), m1(34), m2(35), m3(36), m4(37)." REVISION "201306011200Z" DESCRIPTION "1) Added the following to tnSyncEBITSPortTable: tnSyncEBITSPortLineCode tnSyncEBITSPortLbo. 2) Added the following to DESCRIPTION Of tnSyncEBITSPortSignalType DS1 SF(4) DS1 ESF(5)." REVISION "201212201200Z" DESCRIPTION "Added the following to tnSyncEBITSPortTable: tnSyncEBITSPortLineImpedance." REVISION "201209011200Z" DESCRIPTION "1) Added DEFVAL to the following: tnSyncESyncMsg - false tnSyncELineRefAssignedPort - none tnSyncELineRefPriority - 0 tnSyncELineRefAdminState - up tnSyncELineRefProvQL - 0. 2) Added the following to tnSyncEActiveRef: lineRef3(6), lineRef5(7). 3) Added the following to DESCRIPTION of tnSyncESwCmdLineRef: 5 - lineref4 6 - lineref5. 4) Added the following to tnSyncELineRefTable: tnSyncELineRefAssociatedPort tnSyncELineRefPriorityOfStationClock tnSyncELineRefLockOutOfStationClock tnSyncELineRefSwStateOfStationClock. 5) Added the following tables: tnSyncEStationClockTable tnSyncEBITSPortTable." REVISION "201205081200Z" DESCRIPTION "1) Added the following to tnSyncELineRefAssignedPort: c22(25), c23(26), c24(27), x1(28), x2(29), x3(30), x4(31). 2) Added infinity time (999999) to tnSyncEWTR." REVISION "201112211200Z" DESCRIPTION "Modified descriptions of following: tnSyncESystemQL tnSyncELineRefIncSSMMsg tnSyncELineRefProvQL." REVISION "201108191200Z" DESCRIPTION "1) Added the following to tnSyncELineRefAssignedPort: c13(16) c14(17) c15(18) c16(19) c17(20) c18(21) c19(22) c20(23) c21(24). 2) Added the following to tnSyncEOutgoingForceSsmTrans: dus(13). 3) Redefined enum values for the following attributes: tnSyncELineRefOperState tnSyncELineRefState. 4) Modified MAX_ACCESS of tnSyncELineLockOut from read-create to read-only. 5) Modified DEFVAL of tnSyncELineRefIncSSMSupp. 6) Modified DESCRIPTION for the following attributes: tnSyncELineRefIncSSMMsg tnSyncELineRefProvQL." REVISION "201107221200Z" DESCRIPTION "1) Added SSM SyncE MIB tables: tnSyncEControlTable tnSyncEPortTable. 2) Redefined enum values for the following attributes: tnSyncEActiveRef tnSyncELineRefOperState. 3) Added the following to tnSyncETable: tnSyncESystemQL. 4) Added the following to tnSyncELineRefTable: tnSyncELineRefIncSSMMsg tnSyncELineRefIncSSMStatus tnSyncELineRefIncSSMSupp tnSyncELineRefProvQL. 5) Modified DESCRIPTION of tnSyncESwCmdLineRef." REVISION "201011301200Z" DESCRIPTION "Changed description for the values of tnSyncESwCmdLineRef." REVISION "201011221200Z" DESCRIPTION "Added tnSyncETable and tnSyncELineRefTable." ::= { tnPortModules 6 } tnSyncEConf OBJECT IDENTIFIER ::= { tnSyncEMIB 1 } tnSyncEGroups OBJECT IDENTIFIER ::= { tnSyncEConf 1 } tnSyncECompliances OBJECT IDENTIFIER ::= { tnSyncEConf 2 } tnSyncEObjs OBJECT IDENTIFIER ::= { tnSyncEMIB 2 } tnSyncEBasics OBJECT IDENTIFIER ::= { tnSyncEObjs 1 } -------------------------------------------------------------------------------- -- Synchronous Ethernet Table -------------------------------------------------------------------------------- tnSyncETable OBJECT-TYPE SYNTAX SEQUENCE OF TnSyncEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Sync-E attributes." ::= { tnSyncEBasics 1 } tnSyncEEntry OBJECT-TYPE SYNTAX TnSyncEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { tnShelfIndex, tnSlotIndex } ::= { tnSyncETable 1 } TnSyncEntry ::= SEQUENCE { tnSyncESyncMsg NokiaSyncStatusMsgType, tnSyncEActiveRef INTEGER, tnSyncEWTR Unsigned32, tnSyncESwCmdLineRef Unsigned32, tnSyncEClkModState INTEGER, tnSyncESystemQL Integer32, tnSyncEQLDegradeThreshold Integer32, tnSyncECurrentActiveLineRefFreqOff Integer32, tnSyncEAlmProfName OCTET STRING } tnSyncESyncMsg OBJECT-TYPE SYNTAX NokiaSyncStatusMsgType MAX-ACCESS read-create STATUS current DESCRIPTION "Determines if the timing reference selection for system timing uses Synchronization Status Message (SSM) Quality Levels or Enhanced Quality Levels." DEFVAL { false } ::= { tnSyncEEntry 1 } tnSyncEActiveRef OBJECT-TYPE SYNTAX INTEGER { none(1), lineRef0(2), lineRef1(3), lineRef2(4), lineRef3(5), lineRef4(6), lineRef5(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the association line reference." DEFVAL { none } ::= { tnSyncEEntry 2 } tnSyncEWTR OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The system timing WTR. Current configurable range: 0 to 12, and 999999." DEFVAL { 5 } ::= { tnSyncEEntry 3 } tnSyncESwCmdLineRef OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The third byte represents the switch command: 1 - nocmd 2 - clear 3 - lockout 4 - forceswitch 5 - mannual 6 - auto 7 - clearlockout. The last byte represents the line reference switch to: 0 - internal 1 - lineref0 2 - lineref1 3 - lineref2 4 - lineref3 5 - lineref4 6 - lineref5." ::= { tnSyncEEntry 4 } tnSyncEClkModState OBJECT-TYPE SYNTAX INTEGER { unknown(1), locked(2), autonomousHoldOver(3), autonomousFreeRunning(4), forcedFreeRunning(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Sync-E clock mode state." ::= { tnSyncEEntry 5 } tnSyncESystemQL OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the system quality level (SSM), shown in following: 31 - not applicable When the NE is in SDH mode: 0 - quality unknown 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU 23 - ePRTC 24 - PRTC 25 - ePRC 26 - eSEC. When the NE is in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS 20 - PNO 23 - ePRTC 24 - PRTC 25 - ePRC." ::= { tnSyncEEntry 6 } tnSyncEQLDegradeThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "The threshold value of SSM quality level degradation for systme timing reference. When the NE is in SDH mode: 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC - Default 23 - ePRTC 24 - PRTC 25 - ePRC 26 - eSEC. When the NE is in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 - Default 23 - ePRTC 24 - PRTC 25 - ePRC." ::= { tnSyncEEntry 7 } tnSyncECurrentActiveLineRefFreqOff OBJECT-TYPE SYNTAX Integer32 UNITS "ppb" MAX-ACCESS read-only STATUS current DESCRIPTION "The current frequency offset of the active timing reference." ::= { tnSyncEEntry 8 } tnSyncEAlmProfName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "." ::= { tnSyncEEntry 9 } ------------------------------------------------------------------------------- -- Synchronous Ethernet Timing Line Reference Map Table -------------------------------------------------------------------------------- tnSyncELineRefTable OBJECT-TYPE SYNTAX SEQUENCE OF TnSyncELineRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of VTS map." ::= { tnSyncEBasics 2 } tnSyncELineRefEntry OBJECT-TYPE SYNTAX TnSyncELineRefEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { tnShelfIndex, tnSlotIndex, tnSyncELineRefIndex } ::= { tnSyncELineRefTable 1 } TnSyncELineRefEntry ::= SEQUENCE { tnSyncELineRefIndex Unsigned32, tnSyncELineRefAssignedPort INTEGER, tnSyncELineRefPriority Unsigned32, tnSyncELineRefAdminState INTEGER, tnSyncELineRefOperState INTEGER, tnSyncELineLockOut TruthValue, tnSyncELineRefState INTEGER, tnSyncELineRefSwState INTEGER, tnSyncELineRefIncSSMMsg Integer32, tnSyncELineRefIncSSMStatus Integer32, tnSyncELineRefIncSSMSupp INTEGER, tnSyncELineRefProvQL Integer32, tnSyncELineRefAssociatedPort InterfaceIndexOrZero, tnSyncELineRefPriorityOfStationClock Unsigned32, tnSyncELineRefLockOutOfStationClock TruthValue, tnSyncELineRefSwStateOfStationClock INTEGER, tnSyncELineRefCurrentFreqOff Integer32, tnSyncELineRefAlmProfName OCTET STRING, tnSyncELineRefIncExtdQLTLVClockID AluWdmPtpClockIdentifier, tnSyncELineRefIncExtdQLTLVMixedClockType INTEGER, tnSyncELineRefIncExtdQLTLVPartialChain INTEGER, tnSyncELineRefIncExtdQLTLVNumeEEC Unsigned32, tnSyncELineRefIncExtdQLTLVNumEEC Unsigned32, tnSyncELineRefProvQLOfStationClock Integer32, tnSyncELineRefIncSSMMsgOfStationClock Integer32, tnSyncELineRefIncSSMStatusOfStationClock Integer32 } tnSyncELineRefIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "The ifIndex of the line reference table." ::= { tnSyncELineRefEntry 1 } tnSyncELineRefAssignedPort OBJECT-TYPE SYNTAX INTEGER { none(1), l1(2), l2(3), c1(4), c2(5), c3(6), c4(7), c5(8), c6(9), c7(10), c8(11), c9(12), c10(13), c11(14), c12(15), c13(16), c14(17), c15(18), c16(19), c17(20), c18(21), c19(22), c20(23), c21(24), c22(25), c23(26), c24(27), x1(28), x2(29), x3(30), x4(31), x5(32), x6(33), m1(34), m2(35), m3(36), m4(37), x7(38), x8(39), x9(40), x10(41), x11(42), x12(43) } MAX-ACCESS read-create STATUS current DESCRIPTION "The assigned port for the line reference." DEFVAL { none } ::= { tnSyncELineRefEntry 2 } tnSyncELineRefPriority OBJECT-TYPE SYNTAX Unsigned32 (0..8) MAX-ACCESS read-create STATUS current DESCRIPTION "Line reference priority. Current configurable range: 0 to 8." DEFVAL { 0 } ::= { tnSyncELineRefEntry 3 } tnSyncELineRefAdminState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The administrative state of the line reference." DEFVAL { up } ::= { tnSyncELineRefEntry 4 } tnSyncELineRefOperState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operating state of the line reference." ::= { tnSyncELineRefEntry 5 } tnSyncELineLockOut OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "If lock out line reference or not." ::= { tnSyncELineRefEntry 6 } tnSyncELineRefState OBJECT-TYPE SYNTAX INTEGER { notAssigned(1), normal(2), signalFailure(3), wtr(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Sync-E line reference state." ::= { tnSyncELineRefEntry 7 } tnSyncELineRefSwState OBJECT-TYPE SYNTAX INTEGER { nocmd(1), forced(2), mansw(3), lockout(4), wtr(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Sync-E line reference switch state." ::= { tnSyncELineRefEntry 8 } tnSyncELineRefIncSSMMsg OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current value of incoming QL on that port. 30 - unstable 31 - not applicable When the NE works in SDH mode: 0 - Unknown 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU 23 - ePRTC 24 - PRTC 25 - ePRC 26 - eSEC When the NE works in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS 20 - PNO 23 - ePRTC 24 - PRTC 25 - ePRC It's applicable only to the timing port with SSM capabilities." ::= { tnSyncELineRefEntry 9 } tnSyncELineRefIncSSMStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current status of incoming QL on that port. 0: Valid 1: Invalid 2: Not Supported 3: Not Applicable It's applicable only to the timing port with SSM capabilities." ::= { tnSyncELineRefEntry 10 } tnSyncELineRefIncSSMSupp OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable or disable the line reference incoming QL processing." DEFVAL { disable } ::= { tnSyncELineRefEntry 11 } tnSyncELineRefProvQL OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Manually provisioned incoming SSM value for the line reference. The value can be: 0 - AUTO When the NE is in SDH mode: 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU 23 - ePRTC 24 - PRTC 25 - ePRC 26 - eSEC When the NE works in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS 20 - PNO 23 - ePRTC 24 - PRTC 25 - ePRC Note: The parameter can be provisioned only when SyncELineRefIncSSMSupp is enabled." DEFVAL { 0 } ::= { tnSyncELineRefEntry 12 } tnSyncELineRefAssociatedPort OBJECT-TYPE SYNTAX InterfaceIndexOrZero MAX-ACCESS read-create STATUS current DESCRIPTION "The associated physical port of the line reference. This parameter replaces tnSyncELineRefAssignedPort in order to support assigning a line reference to a port in other slots." DEFVAL { 0 } ::= { tnSyncELineRefEntry 13 } tnSyncELineRefPriorityOfStationClock OBJECT-TYPE SYNTAX Unsigned32 (0..8) MAX-ACCESS read-create STATUS current DESCRIPTION "Line reference priority for the output station clock. Current configurable range: 0 to 8." DEFVAL { 0 } ::= { tnSyncELineRefEntry 14 } tnSyncELineRefLockOutOfStationClock OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "If lock out the line reference or not for the output station clock." ::= { tnSyncELineRefEntry 15 } tnSyncELineRefSwStateOfStationClock OBJECT-TYPE SYNTAX INTEGER { nocmd(1), forced(2), mansw(3), lockout(4), wtr(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Sync-E line reference switch state of the output station clock." ::= { tnSyncELineRefEntry 16 } tnSyncELineRefCurrentFreqOff OBJECT-TYPE SYNTAX Integer32 UNITS "ppb" MAX-ACCESS read-only STATUS current DESCRIPTION "The current frequency offset of the timing reference." ::= { tnSyncELineRefEntry 17 } tnSyncELineRefAlmProfName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "." ::= { tnSyncELineRefEntry 18 } tnSyncELineRefIncExtdQLTLVClockID OBJECT-TYPE SYNTAX AluWdmPtpClockIdentifier MAX-ACCESS read-only STATUS current DESCRIPTION "Incoming Extended QL TLV Clock ID." ::= { tnSyncELineRefEntry 19 } tnSyncELineRefIncExtdQLTLVMixedClockType OBJECT-TYPE SYNTAX INTEGER { eEECFull(1), eEECMixedEEC(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Incoming Extended QL TLV Mixed Clock Type Flag." ::= { tnSyncELineRefEntry 20 } tnSyncELineRefIncExtdQLTLVPartialChain OBJECT-TYPE SYNTAX INTEGER { completeChain(1), partialChain(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Incoming Extended QL TLV Partial Chain Flag." ::= { tnSyncELineRefEntry 21 } tnSyncELineRefIncExtdQLTLVNumeEEC OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Incoming Extended QL TLV Number of eEEC." ::= { tnSyncELineRefEntry 22 } tnSyncELineRefIncExtdQLTLVNumEEC OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Incoming Extended QL TLV Number of EEC." ::= { tnSyncELineRefEntry 23 } tnSyncELineRefProvQLOfStationClock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Manually provisioned incoming SSM value of the line reference output timing. The value can be: 0 - AUTO When the NE is in SDH mode: 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU 23 - ePRTC 24 - PRTC 25 - ePRC 26 - eSEC When the NE works in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS 20 - PNO 23 - ePRTC 24 - PRTC 25 - ePRC Note: The parameter can be provisioned only when SyncELineRefIncSSMSupp is enabled." DEFVAL { 0 } ::= { tnSyncELineRefEntry 24 } tnSyncELineRefIncSSMMsgOfStationClock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current value of incoming QL for output timing on that port. 30 - unstable 31 - not applicable When the NE works in SDH mode: 0 - Unknown 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU 23 - ePRTC 24 - PRTC 25 - ePRC 26 - eSEC When the NE works in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS 20 - PNO 23 - ePRTC 24 - PRTC 25 - ePRC It's applicable only to the timing port with SSM capabilities." ::= { tnSyncELineRefEntry 25 } tnSyncELineRefIncSSMStatusOfStationClock OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current status of incoming QL on that port for output timing. 0: Valid 1: Invalid 2: Not Supported 3: Not Applicable It's applicable only to the timing port with SSM capabilities." ::= { tnSyncELineRefEntry 26 } -------------------------------------------------------------------------------- -- Synchronous Ethernet Control Table -------------------------------------------------------------------------------- tnSyncEControlTable OBJECT-TYPE SYNTAX SEQUENCE OF TnSyncControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Sync-E Control attributes." ::= { tnSyncEBasics 3 } tnSyncEControlEntry OBJECT-TYPE SYNTAX TnSyncControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { tnShelfIndex, tnSlotIndex } ::= { tnSyncEControlTable 1 } TnSyncControlEntry ::= SEQUENCE { tnSyncEControlEECEnable INTEGER } tnSyncEControlEECEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "enable - The Synchronous Ethernet is supported for the pack and the synchronization attributes can be configured. disable - The Synchronous Ethernet is not supported for the pack and the synchronization attributes can not be configured." DEFVAL { disable } ::= { tnSyncEControlEntry 1 } -------------------------------------------------------------------------------- -- Synchronous Ethernet Port Table -------------------------------------------------------------------------------- tnSyncEPortTable OBJECT-TYPE SYNTAX SEQUENCE OF TnSyncPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Sync-E Port attributes." ::= { tnSyncEBasics 4 } tnSyncEPortEntry OBJECT-TYPE SYNTAX TnSyncPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { ifIndex } ::= { tnSyncEPortTable 1 } TnSyncPortEntry ::= SEQUENCE { tnSyncEOprMode INTEGER, tnSyncEOutgoingForceSsmTrans INTEGER } tnSyncEOprMode OBJECT-TYPE SYNTAX INTEGER { sync(1), non-sync(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The port Synchronous Ethernet Operation Mode. When the port is in SYNC mode, recovered clock of its input signal can be selected as a reference clock to the system clock. When the port is in NON-SYNC mode, the recovered clock of its input signal shall not be a candidate to system timing references." DEFVAL { sync } ::= { tnSyncEPortEntry 1 } tnSyncEOutgoingForceSsmTrans OBJECT-TYPE SYNTAX INTEGER { act(1), prc(2), ssua(3), ssub(4), sec(5), dnu(6), stu(7), prs(8), st2(9), sts3e(10), st3(11), none(12), dus(13), ePRTC(23), pRTC(24), ePRC(25), eSEC(26) } MAX-ACCESS read-create STATUS current DESCRIPTION "The port SSM/Quality Level Transmission value. The value can be: In SDH mode - act, prc, ssua, ssub, sec, dnu, ePRTC, PRTC, ePRC, eSEC, none; In sonet mode - act, stu, prs, st2, sts3e, st3, ePRTC, PRTC, ePRC, dus, none." DEFVAL { act } ::= { tnSyncEPortEntry 2 } -------------------------------------------------------------------------------- -- Synchronous Ethernet Station Clock Table -------------------------------------------------------------------------------- tnSyncEStationClockTable OBJECT-TYPE SYNTAX SEQUENCE OF TnSyncEStationClockEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Sync-E station clock attributes." ::= { tnSyncEBasics 5 } tnSyncEStationClockEntry OBJECT-TYPE SYNTAX TnSyncEStationClockEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { tnShelfIndex, tnSlotIndex } ::= { tnSyncEStationClockTable 1 } TnSyncEStationClockEntry ::= SEQUENCE { tnSyncEStationClockSyncMsg NokiaSyncStatusMsgType, tnSyncEStationClockActiveRef INTEGER, tnSyncEStationClockWTR Unsigned32, tnSyncEStationClockSwCmdLineRef Unsigned32, tnSyncEStationClockSystemQL Integer32, tnSyncEStationClockQLThreshold Integer32, tnSyncEStationClockOutSel INTEGER, tnSyncEStationClockAlmProfName OCTET STRING } tnSyncEStationClockSyncMsg OBJECT-TYPE SYNTAX NokiaSyncStatusMsgType MAX-ACCESS read-create STATUS current DESCRIPTION "Determines if the timing reference selection for station clock timing uses Synchronization Status Message (SSM) Quality Levels or Enhanced Quality Levels." DEFVAL { false } ::= { tnSyncEStationClockEntry 1 } tnSyncEStationClockActiveRef OBJECT-TYPE SYNTAX INTEGER { none(1), lineRef0(2), lineRef1(3), lineRef2(4), lineRef3(5), lineRef4(6), lineRef5(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "The ID of the association line reference." DEFVAL { none } ::= { tnSyncEStationClockEntry 2 } tnSyncEStationClockWTR OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The station clock timing WTR. Current configurable range: 0 to 12, and 999999." DEFVAL { 5 } ::= { tnSyncEStationClockEntry 3 } tnSyncEStationClockSwCmdLineRef OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION "The third byte represents the switch command: 1 - nocmd 2 - clear 3 - lockout 4 - forceswitch 5 - mannual 6 - auto 7 - clearlockout. The last byte represents the line reference switch to: 0 - internal 1 - lineref0 2 - lineref1 3 - lineref2 4 - lineref3 5 - lineref4 6 - lineref5." ::= { tnSyncEStationClockEntry 4 } tnSyncEStationClockSystemQL OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the system quality level (SSM) for the output timing clock, shown in following: 31 - not applicable When the NE is in SDH mode: 0 - quality unknown 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU 23 - ePRTC 24 - PRTC 25 - ePRC 26 - eSEC. When the NE is in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS 20 - PNO 23 - ePRTC 24 - PRTC 25 - ePRC." ::= { tnSyncEStationClockEntry 5} tnSyncEStationClockQLThreshold OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the threshold value for the quality level i.e., SSM value for squelching the output towards timing output. If the quality value of the current selected signal for the output is below the threshold value, the output will be squelched. The squelching can be disabled by means of using the value DNU or DUS. When the NE is in SDH mode: 1 - PRC 2 - SSU_A 3 - SSU_B 4 - SEC 5 - DNU 23 - ePRTC 24 - PRTC 25 - ePRC 26 - eSEC. When the NE is in SONET mode: 11 - PRS 12 - STU 13 - ST2 14 - TNC 15 - ST3E 16 - ST3 17 - SMC 18 - ST4 19 - DUS 23 - ePRTC 24 - PRTC 25 - ePRC. Default value: SEC - for node working in SDH mode ST3 - for node working in SONET mode" DEFVAL { 4 } ::= { tnSyncEStationClockEntry 6} tnSyncEStationClockOutSel OBJECT-TYPE SYNTAX INTEGER { outtim(1), setg(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies which signal is selected for the output station clock: OUTTIM - Output is selected from output timing selection process SETG - Output is selected from system internal timing The ID of the association line reference." DEFVAL { outtim } ::= { tnSyncEStationClockEntry 7 } tnSyncEStationClockAlmProfName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "." ::= { tnSyncEStationClockEntry 8 } -------------------------------------------------------------------------------- -- Synchronous Ethernet BITS Port Table -------------------------------------------------------------------------------- tnSyncEBITSPortTable OBJECT-TYPE SYNTAX SEQUENCE OF TnSyncEBITSPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of BITS port attributes." ::= { tnSyncEBasics 6 } tnSyncEBITSPortEntry OBJECT-TYPE SYNTAX TnSyncEBITSPortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { ifIndex } ::= { tnSyncEBITSPortTable 1 } TnSyncEBITSPortEntry ::= SEQUENCE { tnSyncEBITSPortDirection INTEGER, tnSyncEBITSPortSignalType Integer32, tnSyncEBITSPortSaBit INTEGER, tnSyncEBITSPortOutputSSMTrans INTEGER, tnSyncEBITSPortOutputAISMode INTEGER, tnSyncEBITSPortLineImpedance INTEGER, tnSyncEBITSPortLineCode INTEGER, tnSyncEBITSPortLbo INTEGER, tnSyncEBITSPortAlmProfName OCTET STRING } tnSyncEBITSPortDirection OBJECT-TYPE SYNTAX INTEGER { input(1), output(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Indicate the direction of the BITS port." ::= { tnSyncEBITSPortEntry 1 } tnSyncEBITSPortSignalType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "Specify the signal type for the BITS interface: 0 - 2MHz 1 - unframed E1 2 - framed E1 without SSM 3 - framed E1 with SSM 4 - DS1 SF 5 - DS1 ESF. In SDH mode, 2MHz and E1 signal types are valid and 2MHz is the default value. In SONET mode, only the DS1 signal types are valid and DS1 SF is the default value." DEFVAL { 0 } ::= { tnSyncEBITSPortEntry 2 } tnSyncEBITSPortSaBit OBJECT-TYPE SYNTAX INTEGER { notApplicable(0), sa4 (1), sa5 (2), sa6 (3), sa7 (4), sa8 (5) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies the Sa bit location used to carry the SSM information. This parameter is only applicable when tnSyncEBITSPortSignalType = 3 (framed E1 with SSM)" DEFVAL { sa4 } ::= { tnSyncEBITSPortEntry 3 } tnSyncEBITSPortOutputSSMTrans OBJECT-TYPE SYNTAX INTEGER { notApplicable(0), act(1), prc(2), ssua(3), ssub(4), sec(5), dnu(6), stu(7), prs(8), st2(9), sts3e(10), st3(11), none(12), dus(13) } MAX-ACCESS read-create STATUS current DESCRIPTION "The port SSM/Quality Level Transmission value. The value can be: In SDH mode - act, prc, ssua, ssub, sec, dnu, none; In sonet mode - act, stu, prs, st2, sts3e, st3, dus, none. Restriction: The parameter is only applicable when tnSyncEBITSPortDirection = output and tnSyncEBITSPortSignalType = 3 (framed E1 with SSM)or 5 (DS1 ESF)." DEFVAL { act } ::= { tnSyncEBITSPortEntry 4 } tnSyncEBITSPortOutputAISMode OBJECT-TYPE SYNTAX INTEGER { notApplicable(0), aismode(1), qlmode(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Specifies which signal is inserted for the timing output port if the output signal is squelched. The parameter is only applicable for output port types supporting SSM. AISMODE - AIS signal is inserted. QLMODE - DUS is inserted as SSM; output is squelched. Restriction: The parameter is only applicable when tnSyncEBITSPortDirection = output and tnSyncEBITSPortSignalType = 3 (framed E1 with SSM) or 5 (DS1 ESF)." DEFVAL { qlmode } ::= { tnSyncEBITSPortEntry 5 } tnSyncEBITSPortLineImpedance OBJECT-TYPE SYNTAX INTEGER { imp75ohms(1), imp120ohms(2), imp100ohms(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Nominal line impedance. When in SDH mode, imp75ohms or imp120ohms could be used and the default is imp120ohms. When in ONET mode, imp100ohms could be used and the default is imp100ohms." DEFVAL { imp120ohms } ::= { tnSyncEBITSPortEntry 6 } tnSyncEBITSPortLineCode OBJECT-TYPE SYNTAX INTEGER { b8zs(1), ami(2), notApplicable(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "Line code. This attribute is applicable when tnSyncEBITSPortSignalType is DS1 SF or DS1 ESF." DEFVAL { b8zs } ::= { tnSyncEBITSPortEntry 7 } tnSyncEBITSPortLbo OBJECT-TYPE SYNTAX INTEGER { lbo(1), lbo1(2), lbo2(3), lbo3(4), lbo4(5), lbo5(6) } MAX-ACCESS read-create STATUS current DESCRIPTION "Line equalization value for the BITS output port, taking one of the following values: - lbo: no compensation - lbo1: 0 to 133 feet - lbo2: 133 to 266 feet - lbo3: 267 to 399 feet - lbo4: 400 to 533 feet - lbo5: 534 to 655 feet This attribute is applicable when tnSyncEBITSPortSignalType is DS1 SF or DS1 ESF." DEFVAL { lbo1 } ::= { tnSyncEBITSPortEntry 8 } tnSyncEBITSPortAlmProfName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(1..40)) MAX-ACCESS read-create STATUS current DESCRIPTION "Alarm profile for BITs port" ::= { tnSyncEBITSPortEntry 9} -------------------------------------------------------------------------------- -- Wan Table -------------------------------------------------------------------------------- tnWanTable OBJECT-TYPE SYNTAX SEQUENCE OF TnWanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Wan attributes." ::= { tnSyncEBasics 7 } tnWanEntry OBJECT-TYPE SYNTAX TnWanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { ifIndex } ::= { tnWanTable 1 } TnWanEntry ::= SEQUENCE { tnWanAlmProfName OCTET STRING, tnWanSyncEOprMode INTEGER, tnWanSyncEOutgoingForceSsmTrans INTEGER, tnWanAdminStatus INTEGER, tnWanOperStatus INTEGER, tnWanStateQualifier TropicStateQualifierType, tnWanOperationalCapability TropicOperationalCapabilityType, tnWanDescription SnmpAdminString } tnWanAlmProfName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "." ::= { tnWanEntry 1 } tnWanSyncEOprMode OBJECT-TYPE SYNTAX INTEGER { sync(1), non-sync(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "The Synchronous Ethernet Operation Mode. When in SYNC mode, recovered clock of its input signal can be selected as a reference clock to the system clock.When in NON-SYNC mode, the recovered clock of its input signal shall not be a candidate to system timing references." DEFVAL { sync } ::= { tnWanEntry 2 } tnWanSyncEOutgoingForceSsmTrans OBJECT-TYPE SYNTAX INTEGER { notApplicable(1), act(2), prc(3), ssua(4), ssub(5), sec(6), dnu(7), stu(8), prs(9), st2(10), sts3e(11), st3(12), none(13), dus(14), ePRTC(23), pRTC(24), ePRC(25), eSEC(26) } MAX-ACCESS read-create STATUS current DESCRIPTION "The port SSM/Quality Level Transmission value. The value can be: In SDH mode - act, prc, ssua, ssub, sec, dnu, ePRTC, PRTC, ePRC, eSEC, none. In SONET mode - act, prs, stu, st2, st3e, st3, ePRTC, PRTC, ePRC, dus, none." DEFVAL { act } ::= { tnWanEntry 3 } tnWanAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Wan administrative state. It may be used to suppress the alarms or disable consequent actions on the WAN entity." DEFVAL { up } ::= { tnWanEntry 4 } tnWanOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "operational state of WAN entity" ::= { tnWanEntry 5 } tnWanStateQualifier OBJECT-TYPE SYNTAX TropicStateQualifierType MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the state qualifier (i.e., the secondary state) of the WAN state." ::= { tnWanEntry 6 } tnWanOperationalCapability OBJECT-TYPE SYNTAX TropicOperationalCapabilityType MAX-ACCESS read-only STATUS current DESCRIPTION "The partiallyEnabled(3) state means an abnormal state." ::= { tnWanEntry 7 } tnWanDescription OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..255)) MAX-ACCESS read-create STATUS current DESCRIPTION "Wan Description." DEFVAL { "" } ::= { tnWanEntry 8 } -------------------------------------------------------------------------------- -- Synchronous Ethernet Packetswitch Control Table -------------------------------------------------------------------------------- tnSyncEPacketswitchControlTable OBJECT-TYPE SYNTAX SEQUENCE OF TnSyncPacketswitchControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of Sync-E Control attributes for a packetswitch. This table provides the same functionality as tnSyncEControlTable, but requires a switchid as an index" ::= { tnSyncEBasics 8 } tnSyncEPacketswitchControlEntry OBJECT-TYPE SYNTAX TnSyncPacketswitchControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "." INDEX { tnSysSwitchId } ::= { tnSyncEPacketswitchControlTable 1 } TnSyncPacketswitchControlEntry ::= SEQUENCE { tnSyncEPacketswitchControlEECEnable INTEGER } tnSyncEPacketswitchControlEECEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "enable - Synchronous Ethernet is supported for the packetswitch and the synchronization attributes can be configured. disable - Synchronous Ethernet is not supported for the packetswitch and the synchronization attributes can not be configured." DEFVAL { disable } ::= { tnSyncEPacketswitchControlEntry 1 } -------------------------------------------------------------------------------- -- Conformance Group Definitions -------------------------------------------------------------------------------- tnSyncEGroup OBJECT-GROUP OBJECTS { tnSyncESyncMsg, tnSyncEActiveRef, tnSyncEWTR, tnSyncESwCmdLineRef, tnSyncEClkModState, tnSyncESystemQL, tnSyncEQLDegradeThreshold, tnSyncECurrentActiveLineRefFreqOff, tnSyncEAlmProfName } STATUS current DESCRIPTION "." ::= { tnSyncEGroups 1 } tnSyncELineRefGroup OBJECT-GROUP OBJECTS { tnSyncELineRefAssignedPort, tnSyncELineRefPriority, tnSyncELineRefAdminState, tnSyncELineRefOperState, tnSyncELineLockOut, tnSyncELineRefState, tnSyncELineRefSwState, tnSyncELineRefIncSSMMsg, tnSyncELineRefIncSSMStatus, tnSyncELineRefIncSSMSupp, tnSyncELineRefProvQL, tnSyncELineRefAssociatedPort, tnSyncELineRefPriorityOfStationClock, tnSyncELineRefLockOutOfStationClock, tnSyncELineRefSwStateOfStationClock, tnSyncELineRefCurrentFreqOff, tnSyncELineRefAlmProfName, tnSyncELineRefIncExtdQLTLVClockID, tnSyncELineRefIncExtdQLTLVMixedClockType, tnSyncELineRefIncExtdQLTLVPartialChain, tnSyncELineRefIncExtdQLTLVNumeEEC, tnSyncELineRefIncExtdQLTLVNumEEC, tnSyncELineRefProvQLOfStationClock, tnSyncELineRefIncSSMMsgOfStationClock, tnSyncELineRefIncSSMStatusOfStationClock } STATUS current DESCRIPTION "." ::= { tnSyncEGroups 2 } tnSyncEControlGroup OBJECT-GROUP OBJECTS { tnSyncEControlEECEnable } STATUS current DESCRIPTION "." ::= { tnSyncEGroups 3 } tnSyncEPortGroup OBJECT-GROUP OBJECTS { tnSyncEOprMode, tnSyncEOutgoingForceSsmTrans } STATUS current DESCRIPTION "." ::= { tnSyncEGroups 4 } tnSyncEStationClockGroup OBJECT-GROUP OBJECTS { tnSyncEStationClockSyncMsg, tnSyncEStationClockActiveRef, tnSyncEStationClockWTR, tnSyncEStationClockSwCmdLineRef, tnSyncEStationClockSystemQL, tnSyncEStationClockQLThreshold, tnSyncEStationClockOutSel, tnSyncEStationClockAlmProfName } STATUS current DESCRIPTION "." ::= { tnSyncEGroups 5 } tnSyncEBITSPortGroup OBJECT-GROUP OBJECTS { tnSyncEBITSPortDirection, tnSyncEBITSPortSignalType, tnSyncEBITSPortSaBit, tnSyncEBITSPortOutputSSMTrans, tnSyncEBITSPortOutputAISMode, tnSyncEBITSPortLineImpedance, tnSyncEBITSPortLineCode, tnSyncEBITSPortLbo, tnSyncEBITSPortAlmProfName } STATUS current DESCRIPTION "." ::= { tnSyncEGroups 6 } tnWanGroup OBJECT-GROUP OBJECTS { tnWanAlmProfName, tnWanSyncEOprMode, tnWanSyncEOutgoingForceSsmTrans, tnWanAdminStatus, tnWanOperStatus, tnWanStateQualifier, tnWanOperationalCapability, tnWanDescription } STATUS current DESCRIPTION "." ::= { tnSyncEGroups 7 } tnSyncEPacketswitchControlGroup OBJECT-GROUP OBJECTS { tnSyncEPacketswitchControlEECEnable } STATUS current DESCRIPTION "." ::= { tnSyncEGroups 8 } -------------------------------------------------------------------------------- -- Compliance Statements (mandatory) -------------------------------------------------------------------------------- tnSyncECompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "." MODULE MANDATORY-GROUPS { tnSyncEGroup, tnSyncELineRefGroup, tnSyncEControlGroup, tnSyncEPortGroup, tnSyncEStationClockGroup, tnSyncEBITSPortGroup, tnWanGroup, tnSyncEPacketswitchControlGroup } ::= { tnSyncECompliances 1 } END -- DEFINITION OF TROPIC-SYNCE-MIB