G6-SMARTOFFICE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Counter32, enterprises,NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString, MacAddress
|
|
FROM SNMPv2-TC
|
|
g6 FROM MICROSENS-G6-MIB
|
|
;
|
|
|
|
device MODULE-IDENTITY --Category
|
|
LAST-UPDATED "201802121619Z"
|
|
ORGANIZATION "MICROSENS GmbH & Co. KG"
|
|
CONTACT-INFO
|
|
"Kueferstrasse 16
|
|
D-59067 Hamm
|
|
Germany
|
|
support@microsens.de
|
|
http://www.microsens.de"
|
|
DESCRIPTION
|
|
"Microsens private MIB for Generation 6 Ethernet Switches"
|
|
|
|
REVISION "201802121619Z"
|
|
DESCRIPTION
|
|
"File creation"
|
|
::= { g6 4 }
|
|
|
|
smartoffice OBJECT IDENTIFIER ::= { device 99 }
|
|
|
|
|
|
|
|
-- *************************** CONFIGURATION SECTION ********************************
|
|
|
|
|
|
smartofficeEnableSmartOffice OBJECT-TYPE -- enable_smart_office
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Generally enable the SmartOffice solution."
|
|
::= { smartoffice 1 }
|
|
|
|
|
|
-- ******************* Begin of directorConfigTable *************************
|
|
|
|
directorConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DirectorConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"General configuration of the director."
|
|
::= { smartoffice 2 }
|
|
|
|
directorConfigEntry OBJECT-TYPE
|
|
SYNTAX DirectorConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { directorConfigIndex }
|
|
::= { directorConfigTable 1 }
|
|
|
|
|
|
DirectorConfigEntry ::= SEQUENCE {
|
|
directorConfigIndex INTEGER,
|
|
directorConfigDomainName DisplayString,
|
|
directorConfigGeneralMode INTEGER ,
|
|
directorConfigActOnUngroupedSensors INTEGER ,
|
|
directorConfigScanLightControllers DisplayString
|
|
}
|
|
|
|
directorConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatically generated"
|
|
::= { directorConfigEntry 1 }
|
|
|
|
directorConfigDomainName OBJECT-TYPE -- domain_name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { directorConfigEntry 2 }
|
|
|
|
directorConfigGeneralMode OBJECT-TYPE -- general_mode
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled (0),
|
|
automatic (1),
|
|
passive (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { directorConfigEntry 3 }
|
|
|
|
directorConfigActOnUngroupedSensors OBJECT-TYPE -- act_on_ungrouped_sensors
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set any sensor attributes which are not configured to be part of a sensor group, will also trigger the regular script execution. This may be selected in smaller setups to save the effort of defining groups. Note that no event rate limiting can be applied to ungrouped sensors and thus using this mode can result in overloading the system leading to sluggish response times."
|
|
::= { directorConfigEntry 4 }
|
|
|
|
directorConfigScanLightControllers OBJECT-TYPE -- scan_light_controllers
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Scan the local network for reachable SmartLightController and display a list."
|
|
::= { directorConfigEntry 5 }
|
|
|
|
|
|
-- ********************* End of directorConfigTable ***********************
|
|
|
|
|
|
-- ******************* Begin of deviceConfigTable *************************
|
|
|
|
deviceConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DeviceConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the configuration of each device under control. A device may contain one or more actor or sensor functions."
|
|
::= { smartoffice 3 }
|
|
|
|
deviceConfigEntry OBJECT-TYPE
|
|
SYNTAX DeviceConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { deviceConfigIndex }
|
|
::= { deviceConfigTable 1 }
|
|
|
|
|
|
DeviceConfigEntry ::= SEQUENCE {
|
|
deviceConfigIndex INTEGER,
|
|
deviceConfigDeviceName DisplayString,
|
|
deviceConfigLocation DisplayString,
|
|
deviceConfigLatitude DisplayString,
|
|
deviceConfigLongitude DisplayString,
|
|
deviceConfigAltitude DisplayString,
|
|
deviceConfigPlacement INTEGER ,
|
|
deviceConfigProductType INTEGER ,
|
|
deviceConfigDeviceId DisplayString,
|
|
deviceConfigNetworkAddress DisplayString,
|
|
deviceConfigAdditionalParameter DisplayString,
|
|
deviceConfigNetworkFailureAction INTEGER ,
|
|
deviceConfigIdentify DisplayString,
|
|
deviceConfigRestart DisplayString,
|
|
deviceConfigCalibrate DisplayString,
|
|
deviceConfigPair DisplayString,
|
|
deviceConfigUnpair DisplayString,
|
|
deviceConfigUpdateFirmware DisplayString
|
|
}
|
|
|
|
deviceConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatically generated"
|
|
::= { deviceConfigEntry 1 }
|
|
|
|
deviceConfigDeviceName OBJECT-TYPE -- device_name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique group name referenced by the director"
|
|
::= { deviceConfigEntry 2 }
|
|
|
|
deviceConfigLocation OBJECT-TYPE -- location
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Free text to describe the position of the controller on the premesis. This value need NOT be savedwithin the sensor itself."
|
|
::= { deviceConfigEntry 3 }
|
|
|
|
deviceConfigLatitude OBJECT-TYPE -- latitude
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value in degrees such as: 50,123"
|
|
::= { deviceConfigEntry 4 }
|
|
|
|
deviceConfigLongitude OBJECT-TYPE -- longitude
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value in degrees such as: 50,123"
|
|
::= { deviceConfigEntry 5 }
|
|
|
|
deviceConfigAltitude OBJECT-TYPE -- altitude
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value in meters."
|
|
::= { deviceConfigEntry 6 }
|
|
|
|
deviceConfigPlacement OBJECT-TYPE -- placement
|
|
SYNTAX INTEGER
|
|
{
|
|
unset (0),
|
|
floor (1),
|
|
wall (2),
|
|
ceiling (3),
|
|
duct (4),
|
|
outside (5),
|
|
desk (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information where to find the controller"
|
|
::= { deviceConfigEntry 7 }
|
|
|
|
deviceConfigProductType OBJECT-TYPE -- product_type
|
|
SYNTAX INTEGER
|
|
{
|
|
virtual (0),
|
|
smartlightController (1),
|
|
directorCascade (2),
|
|
hm (3),
|
|
fhem (4),
|
|
ip500 (5),
|
|
enocean (6),
|
|
knx (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines via which network the sensor is reachable."
|
|
::= { deviceConfigEntry 8 }
|
|
|
|
deviceConfigDeviceId OBJECT-TYPE -- device_id
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique manufacturer dependent identifier of the device. For SmartLightController the MAC address of the controller is entered here."
|
|
::= { deviceConfigEntry 9 }
|
|
|
|
deviceConfigNetworkAddress OBJECT-TYPE -- network_address
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"May be an IP or other type of address depending on the given network access method. Can be left blank for a SmartLightController."
|
|
::= { deviceConfigEntry 10 }
|
|
|
|
deviceConfigAdditionalParameter OBJECT-TYPE -- additional_parameter
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Comma separated list of any parameter specific for this device. Example: panel=type A,refresh_rate=12"
|
|
::= { deviceConfigEntry 11 }
|
|
|
|
deviceConfigNetworkFailureAction OBJECT-TYPE -- network_failure_action
|
|
SYNTAX INTEGER
|
|
{
|
|
keepCurrent (0),
|
|
off (1),
|
|
on (2),
|
|
dimmed (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines what the actor does if the network connection fails or after reboot until communication is established."
|
|
::= { deviceConfigEntry 12 }
|
|
|
|
deviceConfigIdentify OBJECT-TYPE -- identify
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actor will blink with its status led to signal its presence and physical location."
|
|
::= { deviceConfigEntry 13 }
|
|
|
|
deviceConfigRestart OBJECT-TYPE -- restart
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Restart the actor."
|
|
::= { deviceConfigEntry 14 }
|
|
|
|
deviceConfigCalibrate OBJECT-TYPE -- calibrate
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start calibration process (if available for this actor type)."
|
|
::= { deviceConfigEntry 15 }
|
|
|
|
deviceConfigPair OBJECT-TYPE -- pair
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start pairing process that couples individual device to this director."
|
|
::= { deviceConfigEntry 16 }
|
|
|
|
deviceConfigUnpair OBJECT-TYPE -- unpair
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Discard exisiting pairing between an individual device and this director."
|
|
::= { deviceConfigEntry 17 }
|
|
|
|
deviceConfigUpdateFirmware OBJECT-TYPE -- update_firmware
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Update the device firmware. When no file name is supplied, the latest version is automatically selected. Alternatively, a specific file name can be supplied to use another version. Use Management.files.firmware.display_files to view a list of available files under the SLC section. (applies to SmartLight Controllers)"
|
|
::= { deviceConfigEntry 18 }
|
|
|
|
|
|
-- ********************* End of deviceConfigTable ***********************
|
|
|
|
|
|
-- ******************* Begin of actorGroupConfigTable *************************
|
|
|
|
actorGroupConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ActorGroupConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines a group of actors that support the same attribute and which shall be set toghter to the same value."
|
|
::= { smartoffice 4 }
|
|
|
|
actorGroupConfigEntry OBJECT-TYPE
|
|
SYNTAX ActorGroupConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { actorGroupConfigIndex }
|
|
::= { actorGroupConfigTable 1 }
|
|
|
|
|
|
ActorGroupConfigEntry ::= SEQUENCE {
|
|
actorGroupConfigIndex INTEGER,
|
|
actorGroupConfigGroupName DisplayString,
|
|
actorGroupConfigAttribute DisplayString,
|
|
actorGroupConfigAssociatedDevices DisplayString,
|
|
actorGroupConfigAdditionalParameter DisplayString,
|
|
actorGroupConfigDefaultValue DisplayString,
|
|
actorGroupConfigValueCaching INTEGER ,
|
|
actorGroupConfigAdditionalScriptName DisplayString,
|
|
actorGroupConfigManualSetValue DisplayString
|
|
}
|
|
|
|
actorGroupConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatically generated"
|
|
::= { actorGroupConfigEntry 1 }
|
|
|
|
actorGroupConfigGroupName OBJECT-TYPE -- group_name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique group name referenced by the director"
|
|
::= { actorGroupConfigEntry 2 }
|
|
|
|
actorGroupConfigAttribute OBJECT-TYPE -- attribute
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The attribute which is configured. Locally, identical attributes of the associated devices listed below are grouped."
|
|
::= { actorGroupConfigEntry 3 }
|
|
|
|
actorGroupConfigAssociatedDevices OBJECT-TYPE -- associated_devices
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of all actors that supply information to a particular group. When an instance is used, here the syntax devicename.instance is used. All records are comma separated."
|
|
::= { actorGroupConfigEntry 4 }
|
|
|
|
actorGroupConfigAdditionalParameter OBJECT-TYPE -- additional_parameter
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Comma separated list of any parameter specific for this attribute if needed."
|
|
::= { actorGroupConfigEntry 5 }
|
|
|
|
actorGroupConfigDefaultValue OBJECT-TYPE -- default_value
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { actorGroupConfigEntry 6 }
|
|
|
|
actorGroupConfigValueCaching OBJECT-TYPE -- value_caching
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When enabled the group target value is saved to local non volaive memory. Should the director restart, the cached values will be restored and send to the devices. This feature is useful to ensure uninterrupted operation even in the event of a system failure or to restore conditions after a power outage."
|
|
::= { actorGroupConfigEntry 7 }
|
|
|
|
actorGroupConfigAdditionalScriptName OBJECT-TYPE -- additional_script_name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the actor group is updated, an additional script, defined here, can be executed to run time consuming functions outside of the standard processing loop. Usually, this field is left empty."
|
|
::= { actorGroupConfigEntry 8 }
|
|
|
|
actorGroupConfigManualSetValue OBJECT-TYPE -- manual_set_value
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This command permits setting of the group value manually bypassing the defined script logic. This is intended for testing only. Important: This manual setting always acts on priority level 8."
|
|
::= { actorGroupConfigEntry 9 }
|
|
|
|
|
|
-- ********************* End of actorGroupConfigTable ***********************
|
|
|
|
|
|
-- ******************* Begin of sensorGroupConfigTable *************************
|
|
|
|
sensorGroupConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorGroupConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines a group of sensors that support the same attribute and whose data should be interpreted together."
|
|
::= { smartoffice 5 }
|
|
|
|
sensorGroupConfigEntry OBJECT-TYPE
|
|
SYNTAX SensorGroupConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { sensorGroupConfigIndex }
|
|
::= { sensorGroupConfigTable 1 }
|
|
|
|
|
|
SensorGroupConfigEntry ::= SEQUENCE {
|
|
sensorGroupConfigIndex INTEGER,
|
|
sensorGroupConfigGroupName DisplayString,
|
|
sensorGroupConfigAttribute DisplayString,
|
|
sensorGroupConfigAssociatedDevices DisplayString,
|
|
sensorGroupConfigValueCaching INTEGER ,
|
|
sensorGroupConfigRunScriptWhen INTEGER ,
|
|
sensorGroupConfigRunScriptDelta DisplayString,
|
|
sensorGroupConfigScriptName DisplayString,
|
|
sensorGroupConfigAdditionalScriptName DisplayString,
|
|
sensorGroupConfigReportMode INTEGER ,
|
|
sensorGroupConfigAdditionalParameter DisplayString,
|
|
sensorGroupConfigLowerBoundary DisplayString,
|
|
sensorGroupConfigUpperBoundary DisplayString,
|
|
sensorGroupConfigBoundaryHysteresis INTEGER ,
|
|
sensorGroupConfigUpdateDelta DisplayString,
|
|
sensorGroupConfigRateLimit Unsigned32,
|
|
sensorGroupConfigClearValues DisplayString
|
|
}
|
|
|
|
sensorGroupConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatically generated"
|
|
::= { sensorGroupConfigEntry 1 }
|
|
|
|
sensorGroupConfigGroupName OBJECT-TYPE -- group_name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique group name referenced by the director"
|
|
::= { sensorGroupConfigEntry 2 }
|
|
|
|
sensorGroupConfigAttribute OBJECT-TYPE -- attribute
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The attribute which is configured. Locally, identical attributes of the associated devices listed below are grouped."
|
|
::= { sensorGroupConfigEntry 3 }
|
|
|
|
sensorGroupConfigAssociatedDevices OBJECT-TYPE -- associated_devices
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of all sensors that supply information to a particular group. When an instance is used, here the syntax devicename.instance is used. All records are comma separated."
|
|
::= { sensorGroupConfigEntry 4 }
|
|
|
|
sensorGroupConfigValueCaching OBJECT-TYPE -- value_caching
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When enabled the group target value is saved to local non volaive memory. Should the director restart, the cached values will be restored and send to the devices. This feature is useful to ensure uninterrupted operation even in the event of a system failure or to restore conditions after a power outage."
|
|
::= { sensorGroupConfigEntry 5 }
|
|
|
|
sensorGroupConfigRunScriptWhen OBJECT-TYPE -- run_script_when
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled (0),
|
|
anyChange (1),
|
|
limitCrossed (2),
|
|
avgAbsolute (3),
|
|
avgPercent (4),
|
|
totalAbsolute (5),
|
|
totalPercent (6),
|
|
newPeakLevel (7),
|
|
anyUpdate (8),
|
|
zeroCrossing (9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines which sensor group status needs to change in order to run the standard (and optional additional_script). This can be used to limit the number of script runs by not following little changes that lead to no effect. This filter is logically behind the sensor specific limits defined elsewhere is this table. When the sensor filter is setup well, then this filter here can be relaxed."
|
|
::= { sensorGroupConfigEntry 6 }
|
|
|
|
sensorGroupConfigRunScriptDelta OBJECT-TYPE -- run_script_delta
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines how much the value can deviate before a value change is reported automatically. Depending on the setting of the report_mode an absolute or a percent value is expected."
|
|
::= { sensorGroupConfigEntry 7 }
|
|
|
|
sensorGroupConfigScriptName OBJECT-TYPE -- script_name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the group is updated and the required conditions are met, the script specified in this parameter is executed. If the parameter is left blank, the standard MS_SmartOfficeControl.ms script is executed. The specified script should not contain any time consuming functions. Syntax: = appname/filename:subroutine The appname and subroutine name are optional. Without appname, the script must be located in xml_cli_scripts folder."
|
|
::= { sensorGroupConfigEntry 8 }
|
|
|
|
sensorGroupConfigAdditionalScriptName OBJECT-TYPE -- additional_script_name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the group is updated and the required conditions are met and a script is defined here, this script is executed in the background after the standard processing for this group has taken place. An additional script, defined here, can be used to run time consuming functions outside of the standard processing loop. Usually, this field is left empty."
|
|
::= { sensorGroupConfigEntry 9 }
|
|
|
|
sensorGroupConfigReportMode OBJECT-TYPE -- report_mode
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled (0),
|
|
passive (1),
|
|
deltaPercent (2),
|
|
deltaAbsolute (3),
|
|
onThreshold (4),
|
|
test (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines if the sensor is passive or actively reports changes and error conditions"
|
|
::= { sensorGroupConfigEntry 10 }
|
|
|
|
sensorGroupConfigAdditionalParameter OBJECT-TYPE -- additional_parameter
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Comma separated list of any parameter specific for this attribute if needed."
|
|
::= { sensorGroupConfigEntry 11 }
|
|
|
|
sensorGroupConfigLowerBoundary OBJECT-TYPE -- lower_boundary
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the measured value of any sensor is equal or below this value an event is raised. The value may be configured directly with a numerical value optionally followed by a unit."
|
|
::= { sensorGroupConfigEntry 12 }
|
|
|
|
sensorGroupConfigUpperBoundary OBJECT-TYPE -- upper_boundary
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the measured value of any sensor is equal or above this value an event is raised. The value may be configured directly with a numerical value optionally followed by a unit."
|
|
::= { sensorGroupConfigEntry 13 }
|
|
|
|
sensorGroupConfigBoundaryHysteresis OBJECT-TYPE -- boundary_hysteresis
|
|
SYNTAX INTEGER
|
|
{
|
|
none (0),
|
|
low (1),
|
|
high (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How much the value must return within bounds before the alarm condition is cleared."
|
|
::= { sensorGroupConfigEntry 14 }
|
|
|
|
sensorGroupConfigUpdateDelta OBJECT-TYPE -- update_delta
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines how much the value can deviate before a value change is reported automatically. Depending on the setting of the report_mode an absolute or a percent value is expected."
|
|
::= { sensorGroupConfigEntry 15 }
|
|
|
|
sensorGroupConfigRateLimit OBJECT-TYPE -- rate_limit
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines how quickly the value is reported. Defined In units of 100ms. 0 means no rate limiting."
|
|
::= { sensorGroupConfigEntry 16 }
|
|
|
|
sensorGroupConfigClearValues OBJECT-TYPE -- clear_values
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clear status values for minimum_peak_hold and maximum_peak_hold."
|
|
::= { sensorGroupConfigEntry 17 }
|
|
|
|
|
|
-- ********************* End of sensorGroupConfigTable ***********************
|
|
|
|
|
|
|
|
-- ****************************** STATUS SECTION ********************************
|
|
|
|
|
|
-- ******************* Begin of deviceInformationTable *************************
|
|
|
|
deviceInformationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DeviceInformationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Summarizes the most important inventory information of each detected device."
|
|
::= { smartoffice 100 }
|
|
|
|
deviceInformationEntry OBJECT-TYPE
|
|
SYNTAX DeviceInformationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { deviceInformationIndex }
|
|
::= { deviceInformationTable 1 }
|
|
|
|
|
|
DeviceInformationEntry ::= SEQUENCE {
|
|
deviceInformationIndex INTEGER,
|
|
deviceInformationName DisplayString,
|
|
deviceInformationHardwareId DisplayString,
|
|
deviceInformationDeviceType INTEGER ,
|
|
deviceInformationOperationalState INTEGER ,
|
|
deviceInformationActorAttributes DisplayString,
|
|
deviceInformationSensorAttributes DisplayString,
|
|
deviceInformationVendorName DisplayString,
|
|
deviceInformationArticleNumber DisplayString,
|
|
deviceInformationSerialNumber DisplayString,
|
|
deviceInformationHardwareRevision DisplayString,
|
|
deviceInformationSoftwareVersion DisplayString,
|
|
deviceInformationAdditionalInfo DisplayString
|
|
}
|
|
|
|
deviceInformationIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatically generated"
|
|
::= { deviceInformationEntry 1 }
|
|
|
|
deviceInformationName OBJECT-TYPE -- name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique name for reference. This is name of the base device."
|
|
::= { deviceInformationEntry 2 }
|
|
|
|
deviceInformationHardwareId OBJECT-TYPE -- hardware_id
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A product specific hardware identification. May for example contain the MAC address."
|
|
::= { deviceInformationEntry 3 }
|
|
|
|
deviceInformationDeviceType OBJECT-TYPE -- device_type
|
|
SYNTAX INTEGER
|
|
{
|
|
unused (0),
|
|
sensor (1),
|
|
actor (2),
|
|
actorSensor (3),
|
|
gateway (4),
|
|
other (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if this is an actor or sensor device."
|
|
::= { deviceInformationEntry 4 }
|
|
|
|
deviceInformationOperationalState OBJECT-TYPE -- operational_state
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
failed (1),
|
|
normal (2),
|
|
testMode (3),
|
|
configError (4),
|
|
unpaired (5),
|
|
notReady (6),
|
|
pairing (7),
|
|
inConfig (8),
|
|
unregistered (9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the operational state of the device. Device (not attribute) specific errors will be indicated here."
|
|
::= { deviceInformationEntry 5 }
|
|
|
|
deviceInformationActorAttributes OBJECT-TYPE -- actor_attributes
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lists which setable actor attributes are provided by this device."
|
|
::= { deviceInformationEntry 6 }
|
|
|
|
deviceInformationSensorAttributes OBJECT-TYPE -- sensor_attributes
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lists which readable sensor attributes are provided by this device."
|
|
::= { deviceInformationEntry 7 }
|
|
|
|
deviceInformationVendorName OBJECT-TYPE -- vendor_name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Vendor or manufacturer name of the device."
|
|
::= { deviceInformationEntry 8 }
|
|
|
|
deviceInformationArticleNumber OBJECT-TYPE -- article_number
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This device article number."
|
|
::= { deviceInformationEntry 9 }
|
|
|
|
deviceInformationSerialNumber OBJECT-TYPE -- serial_number
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This device serial number."
|
|
::= { deviceInformationEntry 10 }
|
|
|
|
deviceInformationHardwareRevision OBJECT-TYPE -- hardware_revision
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This device hardware version."
|
|
::= { deviceInformationEntry 11 }
|
|
|
|
deviceInformationSoftwareVersion OBJECT-TYPE -- software_version
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This device software / firmware version."
|
|
::= { deviceInformationEntry 12 }
|
|
|
|
deviceInformationAdditionalInfo OBJECT-TYPE -- additional_info
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Optional comma separated list of status fields specific for this type of device."
|
|
::= { deviceInformationEntry 13 }
|
|
|
|
|
|
-- ********************* End of deviceInformationTable ***********************
|
|
|
|
|
|
-- ******************* Begin of actorListTable *************************
|
|
|
|
actorListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ActorListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists all currenly registered actors with all their attributes."
|
|
::= { smartoffice 101 }
|
|
|
|
actorListEntry OBJECT-TYPE
|
|
SYNTAX ActorListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { actorListIndex }
|
|
::= { actorListTable 1 }
|
|
|
|
|
|
ActorListEntry ::= SEQUENCE {
|
|
actorListIndex INTEGER,
|
|
actorListDevice DisplayString,
|
|
actorListInstance DisplayString,
|
|
actorListAttribute DisplayString,
|
|
actorListAssociatedGroups DisplayString,
|
|
actorListValue DisplayString,
|
|
actorListActorState INTEGER ,
|
|
actorListLastUpdate Counter32
|
|
}
|
|
|
|
actorListIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatically generated"
|
|
::= { actorListEntry 1 }
|
|
|
|
actorListDevice OBJECT-TYPE -- device
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is name of the base device which controls this actor. There may be several actor types (attributes) in the same device and these share the same name but use different attributes. There may also be several similar actor attribues. These are differentiated with the instance parameter."
|
|
::= { actorListEntry 2 }
|
|
|
|
actorListInstance OBJECT-TYPE -- instance
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes a unique instance when several similar functional attributes are existing in the same device"
|
|
::= { actorListEntry 3 }
|
|
|
|
actorListAttribute OBJECT-TYPE -- attribute
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The kind of function this actor is acting on"
|
|
::= { actorListEntry 4 }
|
|
|
|
actorListAssociatedGroups OBJECT-TYPE -- associated_groups
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates in which actor_groups this actor takes part."
|
|
::= { actorListEntry 5 }
|
|
|
|
actorListValue OBJECT-TYPE -- value
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The currently set value as text string followed by the unit such as mA or Lux."
|
|
::= { actorListEntry 6 }
|
|
|
|
actorListActorState OBJECT-TYPE -- actor_state
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
ok (1),
|
|
requested (2),
|
|
retrying (3),
|
|
confirmed (4),
|
|
denied (5),
|
|
failed (6),
|
|
restored (7),
|
|
manually (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates wether the indicated value was successfully written to the actual device."
|
|
::= { actorListEntry 7 }
|
|
|
|
actorListLastUpdate OBJECT-TYPE -- last_update
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the time when this record was last updated."
|
|
::= { actorListEntry 8 }
|
|
|
|
|
|
-- ********************* End of actorListTable ***********************
|
|
|
|
|
|
-- ******************* Begin of sensorListTable *************************
|
|
|
|
sensorListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists all currenly registered sensors with all their attributes."
|
|
::= { smartoffice 102 }
|
|
|
|
sensorListEntry OBJECT-TYPE
|
|
SYNTAX SensorListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { sensorListIndex }
|
|
::= { sensorListTable 1 }
|
|
|
|
|
|
SensorListEntry ::= SEQUENCE {
|
|
sensorListIndex INTEGER,
|
|
sensorListDevice DisplayString,
|
|
sensorListInstance DisplayString,
|
|
sensorListAttribute DisplayString,
|
|
sensorListAssociatedGroups DisplayString,
|
|
sensorListValue DisplayString,
|
|
sensorListSensorState INTEGER ,
|
|
sensorListLastUpdate Counter32
|
|
}
|
|
|
|
sensorListIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatically generated"
|
|
::= { sensorListEntry 1 }
|
|
|
|
sensorListDevice OBJECT-TYPE -- device
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is name of the base device which controls this sensor. There may be several different sensor types (attributes) in the same device. These share the same name but use different attributes. There may also be several similar sensors in the device. These are differentiated with the instance parameter."
|
|
::= { sensorListEntry 2 }
|
|
|
|
sensorListInstance OBJECT-TYPE -- instance
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes a unique instance when several similar functional attributes are existing in the same device"
|
|
::= { sensorListEntry 3 }
|
|
|
|
sensorListAttribute OBJECT-TYPE -- attribute
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The kind of measurement this sensor is reporting."
|
|
::= { sensorListEntry 4 }
|
|
|
|
sensorListAssociatedGroups OBJECT-TYPE -- associated_groups
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates in which sensor_groups this sensor takes part."
|
|
::= { sensorListEntry 5 }
|
|
|
|
sensorListValue OBJECT-TYPE -- value
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last reported value as text string followed by the unit such as mA or Lux."
|
|
::= { sensorListEntry 6 }
|
|
|
|
sensorListSensorState OBJECT-TYPE -- sensor_state
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
ok (1),
|
|
lowBatt (2),
|
|
lowerLimit (3),
|
|
upperLimit (4),
|
|
commFailed (5),
|
|
deviceFailed (6),
|
|
manually (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates particular sensor states such hitting a boundary."
|
|
::= { sensorListEntry 7 }
|
|
|
|
sensorListLastUpdate OBJECT-TYPE -- last_update
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the time when this record was last updated."
|
|
::= { sensorListEntry 8 }
|
|
|
|
|
|
-- ********************* End of sensorListTable ***********************
|
|
|
|
|
|
-- ******************* Begin of actorGroupStatusTable *************************
|
|
|
|
actorGroupStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ActorGroupStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Calculated status of the defined actor groups. The listed value reflects the value all associated actors should use. The values update when an actor group is set by a script or manually."
|
|
::= { smartoffice 103 }
|
|
|
|
actorGroupStatusEntry OBJECT-TYPE
|
|
SYNTAX ActorGroupStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { actorGroupStatusIndex }
|
|
::= { actorGroupStatusTable 1 }
|
|
|
|
|
|
ActorGroupStatusEntry ::= SEQUENCE {
|
|
actorGroupStatusIndex INTEGER,
|
|
actorGroupStatusGroupName DisplayString,
|
|
actorGroupStatusAttribute DisplayString,
|
|
actorGroupStatusNumAssignedActors Integer32 ,
|
|
actorGroupStatusNumFailedActors Integer32 ,
|
|
actorGroupStatusGroupState INTEGER ,
|
|
actorGroupStatusValue DisplayString,
|
|
actorGroupStatusActivePriority Unsigned32,
|
|
actorGroupStatusPriorityValueChain DisplayString,
|
|
actorGroupStatusCacheStatus INTEGER ,
|
|
actorGroupStatusLastUpdate Counter32
|
|
}
|
|
|
|
actorGroupStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatically generated"
|
|
::= { actorGroupStatusEntry 1 }
|
|
|
|
actorGroupStatusGroupName OBJECT-TYPE -- group_name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is name mirrors the actor_group_configuration."
|
|
::= { actorGroupStatusEntry 2 }
|
|
|
|
actorGroupStatusAttribute OBJECT-TYPE -- attribute
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the controlled attribute."
|
|
::= { actorGroupStatusEntry 3 }
|
|
|
|
actorGroupStatusNumAssignedActors OBJECT-TYPE -- num_assigned_actors
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of actors that are configured for this group."
|
|
::= { actorGroupStatusEntry 4 }
|
|
|
|
actorGroupStatusNumFailedActors OBJECT-TYPE -- num_failed_actors
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of actors that have not responded as expected."
|
|
::= { actorGroupStatusEntry 5 }
|
|
|
|
actorGroupStatusGroupState OBJECT-TYPE -- group_state
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
ok (1),
|
|
updating (2),
|
|
unreliable (3),
|
|
manually (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { actorGroupStatusEntry 6 }
|
|
|
|
actorGroupStatusValue OBJECT-TYPE -- value
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is set by the decision logic. May contain simple on,OFF or for example a sound file name"
|
|
::= { actorGroupStatusEntry 7 }
|
|
|
|
actorGroupStatusActivePriority OBJECT-TYPE -- active_priority
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates which priority level is currently controlling the group value. Lower values have higher priority."
|
|
::= { actorGroupStatusEntry 8 }
|
|
|
|
actorGroupStatusPriorityValueChain OBJECT-TYPE -- priority_value_chain
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the prority=value pairs of all currently defined priority levels. Relinquished priorites are not shown."
|
|
::= { actorGroupStatusEntry 9 }
|
|
|
|
actorGroupStatusCacheStatus OBJECT-TYPE -- cache_status
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
disabled (1),
|
|
pending (2),
|
|
saved (3),
|
|
failed (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if this group_status is saved even upon system power loss or reboot."
|
|
::= { actorGroupStatusEntry 10 }
|
|
|
|
actorGroupStatusLastUpdate OBJECT-TYPE -- last_update
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the time when this group status was last updated."
|
|
::= { actorGroupStatusEntry 11 }
|
|
|
|
|
|
-- ********************* End of actorGroupStatusTable ***********************
|
|
|
|
|
|
-- ******************* Begin of sensorGroupStatusTable *************************
|
|
|
|
sensorGroupStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorGroupStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Calculated status for all sensor groups. The sensor values of all contributing sensors are used to calculate min, max and average values. The values update each time a sensor reports changes."
|
|
::= { smartoffice 104 }
|
|
|
|
sensorGroupStatusEntry OBJECT-TYPE
|
|
SYNTAX SensorGroupStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { sensorGroupStatusIndex }
|
|
::= { sensorGroupStatusTable 1 }
|
|
|
|
|
|
SensorGroupStatusEntry ::= SEQUENCE {
|
|
sensorGroupStatusIndex INTEGER,
|
|
sensorGroupStatusGroupName DisplayString,
|
|
sensorGroupStatusAttribute DisplayString,
|
|
sensorGroupStatusNumAssignedSensors Integer32 ,
|
|
sensorGroupStatusNumFailedSensors Integer32 ,
|
|
sensorGroupStatusGroupState INTEGER ,
|
|
sensorGroupStatusMinimumPeakHold DisplayString,
|
|
sensorGroupStatusMinimumValue DisplayString,
|
|
sensorGroupStatusAverageValue DisplayString,
|
|
sensorGroupStatusMaximumValue DisplayString,
|
|
sensorGroupStatusMaximumPeakHold DisplayString,
|
|
sensorGroupStatusTotalValue DisplayString,
|
|
sensorGroupStatusLowerBoundaryReached Integer32 ,
|
|
sensorGroupStatusUpperBoundaryReached Integer32 ,
|
|
sensorGroupStatusUpdatingSensorIndex Integer32 ,
|
|
sensorGroupStatusCacheStatus INTEGER ,
|
|
sensorGroupStatusLastUpdate Counter32
|
|
}
|
|
|
|
sensorGroupStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatically generated"
|
|
::= { sensorGroupStatusEntry 1 }
|
|
|
|
sensorGroupStatusGroupName OBJECT-TYPE -- group_name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is name mirrors the sensor_group_configuration."
|
|
::= { sensorGroupStatusEntry 2 }
|
|
|
|
sensorGroupStatusAttribute OBJECT-TYPE -- attribute
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the attribute measured. E.g. brightness, motion, switch."
|
|
::= { sensorGroupStatusEntry 3 }
|
|
|
|
sensorGroupStatusNumAssignedSensors OBJECT-TYPE -- num_assigned_sensors
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sensors that are configured for this group."
|
|
::= { sensorGroupStatusEntry 4 }
|
|
|
|
sensorGroupStatusNumFailedSensors OBJECT-TYPE -- num_failed_sensors
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sensors that have not responded as expected."
|
|
::= { sensorGroupStatusEntry 5 }
|
|
|
|
sensorGroupStatusGroupState OBJECT-TYPE -- group_state
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
ok (1),
|
|
updating (2),
|
|
unreliable (3),
|
|
manually (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Informs when not all sensors operate as expected."
|
|
::= { sensorGroupStatusEntry 6 }
|
|
|
|
sensorGroupStatusMinimumPeakHold OBJECT-TYPE -- minimum_peak_hold
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value ever reported in this group since last value clear."
|
|
::= { sensorGroupStatusEntry 7 }
|
|
|
|
sensorGroupStatusMinimumValue OBJECT-TYPE -- minimum_value
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value out of all sensors that report to this group."
|
|
::= { sensorGroupStatusEntry 8 }
|
|
|
|
sensorGroupStatusAverageValue OBJECT-TYPE -- average_value
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value out of all sensors that report to this group. Uses the number of reporting sensors to calculate the average."
|
|
::= { sensorGroupStatusEntry 9 }
|
|
|
|
sensorGroupStatusMaximumValue OBJECT-TYPE -- maximum_value
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value out of all sensors that report to this group."
|
|
::= { sensorGroupStatusEntry 10 }
|
|
|
|
sensorGroupStatusMaximumPeakHold OBJECT-TYPE -- maximum_peak_hold
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value ever reported in this group since last value clear."
|
|
::= { sensorGroupStatusEntry 11 }
|
|
|
|
sensorGroupStatusTotalValue OBJECT-TYPE -- total_value
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total sum of all individual sensor values in this group."
|
|
::= { sensorGroupStatusEntry 12 }
|
|
|
|
sensorGroupStatusLowerBoundaryReached OBJECT-TYPE -- lower_boundary_reached
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sensors that have reached their lower threshold. A value of 0 means no sensor has reached a lower boundary."
|
|
::= { sensorGroupStatusEntry 13 }
|
|
|
|
sensorGroupStatusUpperBoundaryReached OBJECT-TYPE -- upper_boundary_reached
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sensors that have reached their upper threshold. A value of 0 means no sensor has reached an upper boundary."
|
|
::= { sensorGroupStatusEntry 14 }
|
|
|
|
sensorGroupStatusUpdatingSensorIndex OBJECT-TYPE -- updating_sensor_index
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the index to the sensor_list which has caused the latest group update."
|
|
::= { sensorGroupStatusEntry 15 }
|
|
|
|
sensorGroupStatusCacheStatus OBJECT-TYPE -- cache_status
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (0),
|
|
disabled (1),
|
|
pending (2),
|
|
saved (3),
|
|
failed (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if this attribute is saved even upon system power loss or reboot."
|
|
::= { sensorGroupStatusEntry 16 }
|
|
|
|
sensorGroupStatusLastUpdate OBJECT-TYPE -- last_update
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the time when this group status was last updated."
|
|
::= { sensorGroupStatusEntry 17 }
|
|
|
|
|
|
-- ********************* End of sensorGroupStatusTable ***********************
|
|
|
|
|
|
|
|