G6-SMARTOFFICE-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Counter32, enterprises,NOTIFICATION-TYPE FROM SNMPv2-SMI DisplayString, MacAddress FROM SNMPv2-TC g6 FROM MICROSENS-G6-MIB ; device MODULE-IDENTITY --Category LAST-UPDATED "201802121619Z" ORGANIZATION "MICROSENS GmbH & Co. KG" CONTACT-INFO "Kueferstrasse 16 D-59067 Hamm Germany support@microsens.de http://www.microsens.de" DESCRIPTION "Microsens private MIB for Generation 6 Ethernet Switches" REVISION "201802121619Z" DESCRIPTION "File creation" ::= { g6 4 } smartoffice OBJECT IDENTIFIER ::= { device 99 } -- *************************** CONFIGURATION SECTION ******************************** smartofficeEnableSmartOffice OBJECT-TYPE -- enable_smart_office SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Generally enable the SmartOffice solution." ::= { smartoffice 1 } -- ******************* Begin of directorConfigTable ************************* directorConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF DirectorConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "General configuration of the director." ::= { smartoffice 2 } directorConfigEntry OBJECT-TYPE SYNTAX DirectorConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { directorConfigIndex } ::= { directorConfigTable 1 } DirectorConfigEntry ::= SEQUENCE { directorConfigIndex INTEGER, directorConfigDomainName DisplayString, directorConfigGeneralMode INTEGER , directorConfigActOnUngroupedSensors INTEGER , directorConfigScanLightControllers DisplayString } directorConfigIndex OBJECT-TYPE SYNTAX INTEGER (0) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { directorConfigEntry 1 } directorConfigDomainName OBJECT-TYPE -- domain_name SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { directorConfigEntry 2 } directorConfigGeneralMode OBJECT-TYPE -- general_mode SYNTAX INTEGER { disabled (0), automatic (1), passive (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { directorConfigEntry 3 } directorConfigActOnUngroupedSensors OBJECT-TYPE -- act_on_ungrouped_sensors SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When set any sensor attributes which are not configured to be part of a sensor group, will also trigger the regular script execution. This may be selected in smaller setups to save the effort of defining groups. Note that no event rate limiting can be applied to ungrouped sensors and thus using this mode can result in overloading the system leading to sluggish response times." ::= { directorConfigEntry 4 } directorConfigScanLightControllers OBJECT-TYPE -- scan_light_controllers SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Scan the local network for reachable SmartLightController and display a list." ::= { directorConfigEntry 5 } -- ********************* End of directorConfigTable *********************** -- ******************* Begin of deviceConfigTable ************************* deviceConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the configuration of each device under control. A device may contain one or more actor or sensor functions." ::= { smartoffice 3 } deviceConfigEntry OBJECT-TYPE SYNTAX DeviceConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { deviceConfigIndex } ::= { deviceConfigTable 1 } DeviceConfigEntry ::= SEQUENCE { deviceConfigIndex INTEGER, deviceConfigDeviceName DisplayString, deviceConfigLocation DisplayString, deviceConfigLatitude DisplayString, deviceConfigLongitude DisplayString, deviceConfigAltitude DisplayString, deviceConfigPlacement INTEGER , deviceConfigProductType INTEGER , deviceConfigDeviceId DisplayString, deviceConfigNetworkAddress DisplayString, deviceConfigAdditionalParameter DisplayString, deviceConfigNetworkFailureAction INTEGER , deviceConfigIdentify DisplayString, deviceConfigRestart DisplayString, deviceConfigCalibrate DisplayString, deviceConfigPair DisplayString, deviceConfigUnpair DisplayString, deviceConfigUpdateFirmware DisplayString } deviceConfigIndex OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { deviceConfigEntry 1 } deviceConfigDeviceName OBJECT-TYPE -- device_name SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Unique group name referenced by the director" ::= { deviceConfigEntry 2 } deviceConfigLocation OBJECT-TYPE -- location SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Free text to describe the position of the controller on the premesis. This value need NOT be savedwithin the sensor itself." ::= { deviceConfigEntry 3 } deviceConfigLatitude OBJECT-TYPE -- latitude SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A value in degrees such as: 50,123" ::= { deviceConfigEntry 4 } deviceConfigLongitude OBJECT-TYPE -- longitude SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A value in degrees such as: 50,123" ::= { deviceConfigEntry 5 } deviceConfigAltitude OBJECT-TYPE -- altitude SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "A value in meters." ::= { deviceConfigEntry 6 } deviceConfigPlacement OBJECT-TYPE -- placement SYNTAX INTEGER { unset (0), floor (1), wall (2), ceiling (3), duct (4), outside (5), desk (6) } MAX-ACCESS read-write STATUS current DESCRIPTION "Information where to find the controller" ::= { deviceConfigEntry 7 } deviceConfigProductType OBJECT-TYPE -- product_type SYNTAX INTEGER { virtual (0), smartlightController (1), directorCascade (2), hm (3), fhem (4), ip500 (5), enocean (6), knx (7) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines via which network the sensor is reachable." ::= { deviceConfigEntry 8 } deviceConfigDeviceId OBJECT-TYPE -- device_id SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Unique manufacturer dependent identifier of the device. For SmartLightController the MAC address of the controller is entered here." ::= { deviceConfigEntry 9 } deviceConfigNetworkAddress OBJECT-TYPE -- network_address SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "May be an IP or other type of address depending on the given network access method. Can be left blank for a SmartLightController." ::= { deviceConfigEntry 10 } deviceConfigAdditionalParameter OBJECT-TYPE -- additional_parameter SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Comma separated list of any parameter specific for this device. Example: panel=type A,refresh_rate=12" ::= { deviceConfigEntry 11 } deviceConfigNetworkFailureAction OBJECT-TYPE -- network_failure_action SYNTAX INTEGER { keepCurrent (0), off (1), on (2), dimmed (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines what the actor does if the network connection fails or after reboot until communication is established." ::= { deviceConfigEntry 12 } deviceConfigIdentify OBJECT-TYPE -- identify SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The actor will blink with its status led to signal its presence and physical location." ::= { deviceConfigEntry 13 } deviceConfigRestart OBJECT-TYPE -- restart SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Restart the actor." ::= { deviceConfigEntry 14 } deviceConfigCalibrate OBJECT-TYPE -- calibrate SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Start calibration process (if available for this actor type)." ::= { deviceConfigEntry 15 } deviceConfigPair OBJECT-TYPE -- pair SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Start pairing process that couples individual device to this director." ::= { deviceConfigEntry 16 } deviceConfigUnpair OBJECT-TYPE -- unpair SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Discard exisiting pairing between an individual device and this director." ::= { deviceConfigEntry 17 } deviceConfigUpdateFirmware OBJECT-TYPE -- update_firmware SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Update the device firmware. When no file name is supplied, the latest version is automatically selected. Alternatively, a specific file name can be supplied to use another version. Use Management.files.firmware.display_files to view a list of available files under the SLC section. (applies to SmartLight Controllers)" ::= { deviceConfigEntry 18 } -- ********************* End of deviceConfigTable *********************** -- ******************* Begin of actorGroupConfigTable ************************* actorGroupConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF ActorGroupConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines a group of actors that support the same attribute and which shall be set toghter to the same value." ::= { smartoffice 4 } actorGroupConfigEntry OBJECT-TYPE SYNTAX ActorGroupConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { actorGroupConfigIndex } ::= { actorGroupConfigTable 1 } ActorGroupConfigEntry ::= SEQUENCE { actorGroupConfigIndex INTEGER, actorGroupConfigGroupName DisplayString, actorGroupConfigAttribute DisplayString, actorGroupConfigAssociatedDevices DisplayString, actorGroupConfigAdditionalParameter DisplayString, actorGroupConfigDefaultValue DisplayString, actorGroupConfigValueCaching INTEGER , actorGroupConfigAdditionalScriptName DisplayString, actorGroupConfigManualSetValue DisplayString } actorGroupConfigIndex OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { actorGroupConfigEntry 1 } actorGroupConfigGroupName OBJECT-TYPE -- group_name SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Unique group name referenced by the director" ::= { actorGroupConfigEntry 2 } actorGroupConfigAttribute OBJECT-TYPE -- attribute SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The attribute which is configured. Locally, identical attributes of the associated devices listed below are grouped." ::= { actorGroupConfigEntry 3 } actorGroupConfigAssociatedDevices OBJECT-TYPE -- associated_devices SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "List of all actors that supply information to a particular group. When an instance is used, here the syntax devicename.instance is used. All records are comma separated." ::= { actorGroupConfigEntry 4 } actorGroupConfigAdditionalParameter OBJECT-TYPE -- additional_parameter SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Comma separated list of any parameter specific for this attribute if needed." ::= { actorGroupConfigEntry 5 } actorGroupConfigDefaultValue OBJECT-TYPE -- default_value SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "" ::= { actorGroupConfigEntry 6 } actorGroupConfigValueCaching OBJECT-TYPE -- value_caching SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled the group target value is saved to local non volaive memory. Should the director restart, the cached values will be restored and send to the devices. This feature is useful to ensure uninterrupted operation even in the event of a system failure or to restore conditions after a power outage." ::= { actorGroupConfigEntry 7 } actorGroupConfigAdditionalScriptName OBJECT-TYPE -- additional_script_name SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "When the actor group is updated, an additional script, defined here, can be executed to run time consuming functions outside of the standard processing loop. Usually, this field is left empty." ::= { actorGroupConfigEntry 8 } actorGroupConfigManualSetValue OBJECT-TYPE -- manual_set_value SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "This command permits setting of the group value manually bypassing the defined script logic. This is intended for testing only. Important: This manual setting always acts on priority level 8." ::= { actorGroupConfigEntry 9 } -- ********************* End of actorGroupConfigTable *********************** -- ******************* Begin of sensorGroupConfigTable ************************* sensorGroupConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorGroupConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines a group of sensors that support the same attribute and whose data should be interpreted together." ::= { smartoffice 5 } sensorGroupConfigEntry OBJECT-TYPE SYNTAX SensorGroupConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sensorGroupConfigIndex } ::= { sensorGroupConfigTable 1 } SensorGroupConfigEntry ::= SEQUENCE { sensorGroupConfigIndex INTEGER, sensorGroupConfigGroupName DisplayString, sensorGroupConfigAttribute DisplayString, sensorGroupConfigAssociatedDevices DisplayString, sensorGroupConfigValueCaching INTEGER , sensorGroupConfigRunScriptWhen INTEGER , sensorGroupConfigRunScriptDelta DisplayString, sensorGroupConfigScriptName DisplayString, sensorGroupConfigAdditionalScriptName DisplayString, sensorGroupConfigReportMode INTEGER , sensorGroupConfigAdditionalParameter DisplayString, sensorGroupConfigLowerBoundary DisplayString, sensorGroupConfigUpperBoundary DisplayString, sensorGroupConfigBoundaryHysteresis INTEGER , sensorGroupConfigUpdateDelta DisplayString, sensorGroupConfigRateLimit Unsigned32, sensorGroupConfigClearValues DisplayString } sensorGroupConfigIndex OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { sensorGroupConfigEntry 1 } sensorGroupConfigGroupName OBJECT-TYPE -- group_name SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Unique group name referenced by the director" ::= { sensorGroupConfigEntry 2 } sensorGroupConfigAttribute OBJECT-TYPE -- attribute SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "The attribute which is configured. Locally, identical attributes of the associated devices listed below are grouped." ::= { sensorGroupConfigEntry 3 } sensorGroupConfigAssociatedDevices OBJECT-TYPE -- associated_devices SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "List of all sensors that supply information to a particular group. When an instance is used, here the syntax devicename.instance is used. All records are comma separated." ::= { sensorGroupConfigEntry 4 } sensorGroupConfigValueCaching OBJECT-TYPE -- value_caching SYNTAX INTEGER { disabled(0), enabled(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "When enabled the group target value is saved to local non volaive memory. Should the director restart, the cached values will be restored and send to the devices. This feature is useful to ensure uninterrupted operation even in the event of a system failure or to restore conditions after a power outage." ::= { sensorGroupConfigEntry 5 } sensorGroupConfigRunScriptWhen OBJECT-TYPE -- run_script_when SYNTAX INTEGER { disabled (0), anyChange (1), limitCrossed (2), avgAbsolute (3), avgPercent (4), totalAbsolute (5), totalPercent (6), newPeakLevel (7), anyUpdate (8), zeroCrossing (9) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines which sensor group status needs to change in order to run the standard (and optional additional_script). This can be used to limit the number of script runs by not following little changes that lead to no effect. This filter is logically behind the sensor specific limits defined elsewhere is this table. When the sensor filter is setup well, then this filter here can be relaxed." ::= { sensorGroupConfigEntry 6 } sensorGroupConfigRunScriptDelta OBJECT-TYPE -- run_script_delta SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Defines how much the value can deviate before a value change is reported automatically. Depending on the setting of the report_mode an absolute or a percent value is expected." ::= { sensorGroupConfigEntry 7 } sensorGroupConfigScriptName OBJECT-TYPE -- script_name SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "When the group is updated and the required conditions are met, the script specified in this parameter is executed. If the parameter is left blank, the standard MS_SmartOfficeControl.ms script is executed. The specified script should not contain any time consuming functions. Syntax: = appname/filename:subroutine The appname and subroutine name are optional. Without appname, the script must be located in xml_cli_scripts folder." ::= { sensorGroupConfigEntry 8 } sensorGroupConfigAdditionalScriptName OBJECT-TYPE -- additional_script_name SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "When the group is updated and the required conditions are met and a script is defined here, this script is executed in the background after the standard processing for this group has taken place. An additional script, defined here, can be used to run time consuming functions outside of the standard processing loop. Usually, this field is left empty." ::= { sensorGroupConfigEntry 9 } sensorGroupConfigReportMode OBJECT-TYPE -- report_mode SYNTAX INTEGER { disabled (0), passive (1), deltaPercent (2), deltaAbsolute (3), onThreshold (4), test (5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Defines if the sensor is passive or actively reports changes and error conditions" ::= { sensorGroupConfigEntry 10 } sensorGroupConfigAdditionalParameter OBJECT-TYPE -- additional_parameter SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Comma separated list of any parameter specific for this attribute if needed." ::= { sensorGroupConfigEntry 11 } sensorGroupConfigLowerBoundary OBJECT-TYPE -- lower_boundary SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "When the measured value of any sensor is equal or below this value an event is raised. The value may be configured directly with a numerical value optionally followed by a unit." ::= { sensorGroupConfigEntry 12 } sensorGroupConfigUpperBoundary OBJECT-TYPE -- upper_boundary SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "When the measured value of any sensor is equal or above this value an event is raised. The value may be configured directly with a numerical value optionally followed by a unit." ::= { sensorGroupConfigEntry 13 } sensorGroupConfigBoundaryHysteresis OBJECT-TYPE -- boundary_hysteresis SYNTAX INTEGER { none (0), low (1), high (2) } MAX-ACCESS read-write STATUS current DESCRIPTION "How much the value must return within bounds before the alarm condition is cleared." ::= { sensorGroupConfigEntry 14 } sensorGroupConfigUpdateDelta OBJECT-TYPE -- update_delta SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Defines how much the value can deviate before a value change is reported automatically. Depending on the setting of the report_mode an absolute or a percent value is expected." ::= { sensorGroupConfigEntry 15 } sensorGroupConfigRateLimit OBJECT-TYPE -- rate_limit SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "Defines how quickly the value is reported. Defined In units of 100ms. 0 means no rate limiting." ::= { sensorGroupConfigEntry 16 } sensorGroupConfigClearValues OBJECT-TYPE -- clear_values SYNTAX DisplayString MAX-ACCESS read-write STATUS current DESCRIPTION "Clear status values for minimum_peak_hold and maximum_peak_hold." ::= { sensorGroupConfigEntry 17 } -- ********************* End of sensorGroupConfigTable *********************** -- ****************************** STATUS SECTION ******************************** -- ******************* Begin of deviceInformationTable ************************* deviceInformationTable OBJECT-TYPE SYNTAX SEQUENCE OF DeviceInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Summarizes the most important inventory information of each detected device." ::= { smartoffice 100 } deviceInformationEntry OBJECT-TYPE SYNTAX DeviceInformationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { deviceInformationIndex } ::= { deviceInformationTable 1 } DeviceInformationEntry ::= SEQUENCE { deviceInformationIndex INTEGER, deviceInformationName DisplayString, deviceInformationHardwareId DisplayString, deviceInformationDeviceType INTEGER , deviceInformationOperationalState INTEGER , deviceInformationActorAttributes DisplayString, deviceInformationSensorAttributes DisplayString, deviceInformationVendorName DisplayString, deviceInformationArticleNumber DisplayString, deviceInformationSerialNumber DisplayString, deviceInformationHardwareRevision DisplayString, deviceInformationSoftwareVersion DisplayString, deviceInformationAdditionalInfo DisplayString } deviceInformationIndex OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { deviceInformationEntry 1 } deviceInformationName OBJECT-TYPE -- name SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Unique name for reference. This is name of the base device." ::= { deviceInformationEntry 2 } deviceInformationHardwareId OBJECT-TYPE -- hardware_id SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A product specific hardware identification. May for example contain the MAC address." ::= { deviceInformationEntry 3 } deviceInformationDeviceType OBJECT-TYPE -- device_type SYNTAX INTEGER { unused (0), sensor (1), actor (2), actorSensor (3), gateway (4), other (5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if this is an actor or sensor device." ::= { deviceInformationEntry 4 } deviceInformationOperationalState OBJECT-TYPE -- operational_state SYNTAX INTEGER { unknown (0), failed (1), normal (2), testMode (3), configError (4), unpaired (5), notReady (6), pairing (7), inConfig (8), unregistered (9) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the operational state of the device. Device (not attribute) specific errors will be indicated here." ::= { deviceInformationEntry 5 } deviceInformationActorAttributes OBJECT-TYPE -- actor_attributes SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Lists which setable actor attributes are provided by this device." ::= { deviceInformationEntry 6 } deviceInformationSensorAttributes OBJECT-TYPE -- sensor_attributes SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Lists which readable sensor attributes are provided by this device." ::= { deviceInformationEntry 7 } deviceInformationVendorName OBJECT-TYPE -- vendor_name SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Vendor or manufacturer name of the device." ::= { deviceInformationEntry 8 } deviceInformationArticleNumber OBJECT-TYPE -- article_number SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This device article number." ::= { deviceInformationEntry 9 } deviceInformationSerialNumber OBJECT-TYPE -- serial_number SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This device serial number." ::= { deviceInformationEntry 10 } deviceInformationHardwareRevision OBJECT-TYPE -- hardware_revision SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This device hardware version." ::= { deviceInformationEntry 11 } deviceInformationSoftwareVersion OBJECT-TYPE -- software_version SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This device software / firmware version." ::= { deviceInformationEntry 12 } deviceInformationAdditionalInfo OBJECT-TYPE -- additional_info SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Optional comma separated list of status fields specific for this type of device." ::= { deviceInformationEntry 13 } -- ********************* End of deviceInformationTable *********************** -- ******************* Begin of actorListTable ************************* actorListTable OBJECT-TYPE SYNTAX SEQUENCE OF ActorListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table lists all currenly registered actors with all their attributes." ::= { smartoffice 101 } actorListEntry OBJECT-TYPE SYNTAX ActorListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { actorListIndex } ::= { actorListTable 1 } ActorListEntry ::= SEQUENCE { actorListIndex INTEGER, actorListDevice DisplayString, actorListInstance DisplayString, actorListAttribute DisplayString, actorListAssociatedGroups DisplayString, actorListValue DisplayString, actorListActorState INTEGER , actorListLastUpdate Counter32 } actorListIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { actorListEntry 1 } actorListDevice OBJECT-TYPE -- device SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is name of the base device which controls this actor. There may be several actor types (attributes) in the same device and these share the same name but use different attributes. There may also be several similar actor attribues. These are differentiated with the instance parameter." ::= { actorListEntry 2 } actorListInstance OBJECT-TYPE -- instance SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Describes a unique instance when several similar functional attributes are existing in the same device" ::= { actorListEntry 3 } actorListAttribute OBJECT-TYPE -- attribute SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The kind of function this actor is acting on" ::= { actorListEntry 4 } actorListAssociatedGroups OBJECT-TYPE -- associated_groups SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates in which actor_groups this actor takes part." ::= { actorListEntry 5 } actorListValue OBJECT-TYPE -- value SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The currently set value as text string followed by the unit such as mA or Lux." ::= { actorListEntry 6 } actorListActorState OBJECT-TYPE -- actor_state SYNTAX INTEGER { unknown (0), ok (1), requested (2), retrying (3), confirmed (4), denied (5), failed (6), restored (7), manually (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates wether the indicated value was successfully written to the actual device." ::= { actorListEntry 7 } actorListLastUpdate OBJECT-TYPE -- last_update SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time when this record was last updated." ::= { actorListEntry 8 } -- ********************* End of actorListTable *********************** -- ******************* Begin of sensorListTable ************************* sensorListTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table lists all currenly registered sensors with all their attributes." ::= { smartoffice 102 } sensorListEntry OBJECT-TYPE SYNTAX SensorListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sensorListIndex } ::= { sensorListTable 1 } SensorListEntry ::= SEQUENCE { sensorListIndex INTEGER, sensorListDevice DisplayString, sensorListInstance DisplayString, sensorListAttribute DisplayString, sensorListAssociatedGroups DisplayString, sensorListValue DisplayString, sensorListSensorState INTEGER , sensorListLastUpdate Counter32 } sensorListIndex OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { sensorListEntry 1 } sensorListDevice OBJECT-TYPE -- device SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is name of the base device which controls this sensor. There may be several different sensor types (attributes) in the same device. These share the same name but use different attributes. There may also be several similar sensors in the device. These are differentiated with the instance parameter." ::= { sensorListEntry 2 } sensorListInstance OBJECT-TYPE -- instance SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Describes a unique instance when several similar functional attributes are existing in the same device" ::= { sensorListEntry 3 } sensorListAttribute OBJECT-TYPE -- attribute SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The kind of measurement this sensor is reporting." ::= { sensorListEntry 4 } sensorListAssociatedGroups OBJECT-TYPE -- associated_groups SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates in which sensor_groups this sensor takes part." ::= { sensorListEntry 5 } sensorListValue OBJECT-TYPE -- value SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The last reported value as text string followed by the unit such as mA or Lux." ::= { sensorListEntry 6 } sensorListSensorState OBJECT-TYPE -- sensor_state SYNTAX INTEGER { unknown (0), ok (1), lowBatt (2), lowerLimit (3), upperLimit (4), commFailed (5), deviceFailed (6), manually (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates particular sensor states such hitting a boundary." ::= { sensorListEntry 7 } sensorListLastUpdate OBJECT-TYPE -- last_update SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time when this record was last updated." ::= { sensorListEntry 8 } -- ********************* End of sensorListTable *********************** -- ******************* Begin of actorGroupStatusTable ************************* actorGroupStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF ActorGroupStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Calculated status of the defined actor groups. The listed value reflects the value all associated actors should use. The values update when an actor group is set by a script or manually." ::= { smartoffice 103 } actorGroupStatusEntry OBJECT-TYPE SYNTAX ActorGroupStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { actorGroupStatusIndex } ::= { actorGroupStatusTable 1 } ActorGroupStatusEntry ::= SEQUENCE { actorGroupStatusIndex INTEGER, actorGroupStatusGroupName DisplayString, actorGroupStatusAttribute DisplayString, actorGroupStatusNumAssignedActors Integer32 , actorGroupStatusNumFailedActors Integer32 , actorGroupStatusGroupState INTEGER , actorGroupStatusValue DisplayString, actorGroupStatusActivePriority Unsigned32, actorGroupStatusPriorityValueChain DisplayString, actorGroupStatusCacheStatus INTEGER , actorGroupStatusLastUpdate Counter32 } actorGroupStatusIndex OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { actorGroupStatusEntry 1 } actorGroupStatusGroupName OBJECT-TYPE -- group_name SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is name mirrors the actor_group_configuration." ::= { actorGroupStatusEntry 2 } actorGroupStatusAttribute OBJECT-TYPE -- attribute SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the controlled attribute." ::= { actorGroupStatusEntry 3 } actorGroupStatusNumAssignedActors OBJECT-TYPE -- num_assigned_actors SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of actors that are configured for this group." ::= { actorGroupStatusEntry 4 } actorGroupStatusNumFailedActors OBJECT-TYPE -- num_failed_actors SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of actors that have not responded as expected." ::= { actorGroupStatusEntry 5 } actorGroupStatusGroupState OBJECT-TYPE -- group_state SYNTAX INTEGER { unknown (0), ok (1), updating (2), unreliable (3), manually (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { actorGroupStatusEntry 6 } actorGroupStatusValue OBJECT-TYPE -- value SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This value is set by the decision logic. May contain simple on,OFF or for example a sound file name" ::= { actorGroupStatusEntry 7 } actorGroupStatusActivePriority OBJECT-TYPE -- active_priority SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates which priority level is currently controlling the group value. Lower values have higher priority." ::= { actorGroupStatusEntry 8 } actorGroupStatusPriorityValueChain OBJECT-TYPE -- priority_value_chain SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Displays the prority=value pairs of all currently defined priority levels. Relinquished priorites are not shown." ::= { actorGroupStatusEntry 9 } actorGroupStatusCacheStatus OBJECT-TYPE -- cache_status SYNTAX INTEGER { unknown (0), disabled (1), pending (2), saved (3), failed (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if this group_status is saved even upon system power loss or reboot." ::= { actorGroupStatusEntry 10 } actorGroupStatusLastUpdate OBJECT-TYPE -- last_update SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time when this group status was last updated." ::= { actorGroupStatusEntry 11 } -- ********************* End of actorGroupStatusTable *********************** -- ******************* Begin of sensorGroupStatusTable ************************* sensorGroupStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF SensorGroupStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Calculated status for all sensor groups. The sensor values of all contributing sensors are used to calculate min, max and average values. The values update each time a sensor reports changes." ::= { smartoffice 104 } sensorGroupStatusEntry OBJECT-TYPE SYNTAX SensorGroupStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { sensorGroupStatusIndex } ::= { sensorGroupStatusTable 1 } SensorGroupStatusEntry ::= SEQUENCE { sensorGroupStatusIndex INTEGER, sensorGroupStatusGroupName DisplayString, sensorGroupStatusAttribute DisplayString, sensorGroupStatusNumAssignedSensors Integer32 , sensorGroupStatusNumFailedSensors Integer32 , sensorGroupStatusGroupState INTEGER , sensorGroupStatusMinimumPeakHold DisplayString, sensorGroupStatusMinimumValue DisplayString, sensorGroupStatusAverageValue DisplayString, sensorGroupStatusMaximumValue DisplayString, sensorGroupStatusMaximumPeakHold DisplayString, sensorGroupStatusTotalValue DisplayString, sensorGroupStatusLowerBoundaryReached Integer32 , sensorGroupStatusUpperBoundaryReached Integer32 , sensorGroupStatusUpdatingSensorIndex Integer32 , sensorGroupStatusCacheStatus INTEGER , sensorGroupStatusLastUpdate Counter32 } sensorGroupStatusIndex OBJECT-TYPE SYNTAX INTEGER (0..63) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Automatically generated" ::= { sensorGroupStatusEntry 1 } sensorGroupStatusGroupName OBJECT-TYPE -- group_name SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "This is name mirrors the sensor_group_configuration." ::= { sensorGroupStatusEntry 2 } sensorGroupStatusAttribute OBJECT-TYPE -- attribute SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the attribute measured. E.g. brightness, motion, switch." ::= { sensorGroupStatusEntry 3 } sensorGroupStatusNumAssignedSensors OBJECT-TYPE -- num_assigned_sensors SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of sensors that are configured for this group." ::= { sensorGroupStatusEntry 4 } sensorGroupStatusNumFailedSensors OBJECT-TYPE -- num_failed_sensors SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of sensors that have not responded as expected." ::= { sensorGroupStatusEntry 5 } sensorGroupStatusGroupState OBJECT-TYPE -- group_state SYNTAX INTEGER { unknown (0), ok (1), updating (2), unreliable (3), manually (8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Informs when not all sensors operate as expected." ::= { sensorGroupStatusEntry 6 } sensorGroupStatusMinimumPeakHold OBJECT-TYPE -- minimum_peak_hold SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum value ever reported in this group since last value clear." ::= { sensorGroupStatusEntry 7 } sensorGroupStatusMinimumValue OBJECT-TYPE -- minimum_value SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum value out of all sensors that report to this group." ::= { sensorGroupStatusEntry 8 } sensorGroupStatusAverageValue OBJECT-TYPE -- average_value SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Average value out of all sensors that report to this group. Uses the number of reporting sensors to calculate the average." ::= { sensorGroupStatusEntry 9 } sensorGroupStatusMaximumValue OBJECT-TYPE -- maximum_value SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum value out of all sensors that report to this group." ::= { sensorGroupStatusEntry 10 } sensorGroupStatusMaximumPeakHold OBJECT-TYPE -- maximum_peak_hold SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum value ever reported in this group since last value clear." ::= { sensorGroupStatusEntry 11 } sensorGroupStatusTotalValue OBJECT-TYPE -- total_value SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The total sum of all individual sensor values in this group." ::= { sensorGroupStatusEntry 12 } sensorGroupStatusLowerBoundaryReached OBJECT-TYPE -- lower_boundary_reached SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of sensors that have reached their lower threshold. A value of 0 means no sensor has reached a lower boundary." ::= { sensorGroupStatusEntry 13 } sensorGroupStatusUpperBoundaryReached OBJECT-TYPE -- upper_boundary_reached SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Number of sensors that have reached their upper threshold. A value of 0 means no sensor has reached an upper boundary." ::= { sensorGroupStatusEntry 14 } sensorGroupStatusUpdatingSensorIndex OBJECT-TYPE -- updating_sensor_index SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the index to the sensor_list which has caused the latest group update." ::= { sensorGroupStatusEntry 15 } sensorGroupStatusCacheStatus OBJECT-TYPE -- cache_status SYNTAX INTEGER { unknown (0), disabled (1), pending (2), saved (3), failed (4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates if this attribute is saved even upon system power loss or reboot." ::= { sensorGroupStatusEntry 16 } sensorGroupStatusLastUpdate OBJECT-TYPE -- last_update SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the time when this group status was last updated." ::= { sensorGroupStatusEntry 17 } -- ********************* End of sensorGroupStatusTable *********************** END