237 lines
5.1 KiB
Plaintext
237 lines
5.1 KiB
Plaintext
G6-EVENT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Counter32, enterprises,NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString, MacAddress
|
|
FROM SNMPv2-TC
|
|
g6 FROM MICROSENS-G6-MIB
|
|
;
|
|
|
|
management MODULE-IDENTITY --Category
|
|
LAST-UPDATED "201802121619Z"
|
|
ORGANIZATION "MICROSENS GmbH & Co. KG"
|
|
CONTACT-INFO
|
|
"Kueferstrasse 16
|
|
D-59067 Hamm
|
|
Germany
|
|
support@microsens.de
|
|
http://www.microsens.de"
|
|
DESCRIPTION
|
|
"Microsens private MIB for Generation 6 Ethernet Switches"
|
|
|
|
REVISION "201802121619Z"
|
|
DESCRIPTION
|
|
"File creation"
|
|
::= { g6 3 }
|
|
|
|
event OBJECT IDENTIFIER ::= { management 70 }
|
|
|
|
|
|
|
|
-- *************************** CONFIGURATION SECTION ********************************
|
|
|
|
|
|
-- ******************* Begin of eventListTable *************************
|
|
|
|
eventListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EventListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { event 1 }
|
|
|
|
eventListEntry OBJECT-TYPE
|
|
SYNTAX EventListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { eventListIndex }
|
|
::= { eventListTable 1 }
|
|
|
|
|
|
EventListEntry ::= SEQUENCE {
|
|
eventListIndex INTEGER,
|
|
eventListName DisplayString,
|
|
eventListGroup INTEGER ,
|
|
eventListRelevance INTEGER ,
|
|
eventListInternal INTEGER ,
|
|
eventListSeverity INTEGER ,
|
|
eventListSource INTEGER ,
|
|
eventListTrap INTEGER ,
|
|
eventListSyslogMessage DisplayString,
|
|
eventListCustomMessage DisplayString,
|
|
eventListIntegerElements DisplayString,
|
|
eventListStringElements DisplayString,
|
|
eventListCliScript DisplayString
|
|
}
|
|
|
|
eventListIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..127)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatically generated"
|
|
::= { eventListEntry 1 }
|
|
|
|
eventListName OBJECT-TYPE -- name
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the event"
|
|
::= { eventListEntry 2 }
|
|
|
|
eventListGroup OBJECT-TYPE -- group
|
|
SYNTAX INTEGER
|
|
{
|
|
internal (0),
|
|
debug (2),
|
|
test (3),
|
|
reset (4),
|
|
firmware (5),
|
|
system (6),
|
|
config (7),
|
|
login (8),
|
|
auth (9),
|
|
power (10),
|
|
temperature (11),
|
|
link (12),
|
|
sfp (13),
|
|
poe (14),
|
|
ring (15),
|
|
ntp (16),
|
|
signals (17),
|
|
script (18),
|
|
filter (19),
|
|
lacp (20),
|
|
app (21),
|
|
cable (22),
|
|
security (23),
|
|
msp1000 (24),
|
|
backup (25),
|
|
fan (26),
|
|
messaging (27),
|
|
terminalServer (28),
|
|
smartOffice (29)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Associated group of this event"
|
|
::= { eventListEntry 3 }
|
|
|
|
eventListRelevance OBJECT-TYPE -- relevance
|
|
SYNTAX INTEGER
|
|
{
|
|
pos (0),
|
|
neg (1),
|
|
info (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Positive, negative or informational event"
|
|
::= { eventListEntry 4 }
|
|
|
|
eventListInternal OBJECT-TYPE -- internal
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If enabled this event cannot be used for syslog or traps"
|
|
::= { eventListEntry 5 }
|
|
|
|
eventListSeverity OBJECT-TYPE -- severity
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled (0),
|
|
debug (1),
|
|
info (2),
|
|
notice (3),
|
|
warning (4),
|
|
error (5),
|
|
critical (6),
|
|
alert (7),
|
|
emergency (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Severity level of this event. Can be modified if required"
|
|
::= { eventListEntry 6 }
|
|
|
|
eventListSource OBJECT-TYPE -- source
|
|
SYNTAX INTEGER
|
|
{
|
|
unit (0),
|
|
port (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit or port related event"
|
|
::= { eventListEntry 7 }
|
|
|
|
eventListTrap OBJECT-TYPE -- trap
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When enabled a trap may be generated for this event"
|
|
::= { eventListEntry 8 }
|
|
|
|
eventListSyslogMessage OBJECT-TYPE -- syslog_message
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fixed event text describing the cause of the event."
|
|
::= { eventListEntry 9 }
|
|
|
|
eventListCustomMessage OBJECT-TYPE -- custom_message
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Here a custom or translated version of the event text may be inserted."
|
|
::= { eventListEntry 10 }
|
|
|
|
eventListIntegerElements OBJECT-TYPE -- integer_elements
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lists which integer value informations are available for the syslog message"
|
|
::= { eventListEntry 11 }
|
|
|
|
eventListStringElements OBJECT-TYPE -- string_elements
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lists which string type informations are available for the syslog message"
|
|
::= { eventListEntry 12 }
|
|
|
|
eventListCliScript OBJECT-TYPE -- cli_script
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When a script name is present the script will be executed whenever this event occurs. Note: Internal events do not trigger scripts even though a script name may be entered. Several scripts may be assigned to a single event. Syntax: app/scriptfile:subroutine para1 para2, next script... All fields besides the scriptfile are optional."
|
|
::= { eventListEntry 13 }
|
|
|
|
|
|
-- ********************* End of eventListTable ***********************
|
|
|
|
|
|
|
|
-- ****************************** STATUS SECTION ********************************
|
|
|
|
|
|
|
|
END
|
|
|