G6-EVENT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, Counter32, enterprises,NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, MacAddress
FROM SNMPv2-TC
g6 FROM MICROSENS-G6-MIB
;
management MODULE-IDENTITY --Category
LAST-UPDATED "201802121619Z"
ORGANIZATION "MICROSENS GmbH & Co. KG"
CONTACT-INFO
"Kueferstrasse 16
D-59067 Hamm
Germany
support@microsens.de
http://www.microsens.de"
DESCRIPTION
"Microsens private MIB for Generation 6 Ethernet Switches"
REVISION "201802121619Z"
DESCRIPTION
"File creation"
::= { g6 3 }
event OBJECT IDENTIFIER ::= { management 70 }
-- *************************** CONFIGURATION SECTION ********************************
-- ******************* Begin of eventListTable *************************
eventListTable OBJECT-TYPE
SYNTAX SEQUENCE OF EventListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
::= { event 1 }
eventListEntry OBJECT-TYPE
SYNTAX EventListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
""
INDEX { eventListIndex }
::= { eventListTable 1 }
EventListEntry ::= SEQUENCE {
eventListIndex INTEGER,
eventListName DisplayString,
eventListGroup INTEGER ,
eventListRelevance INTEGER ,
eventListInternal INTEGER ,
eventListSeverity INTEGER ,
eventListSource INTEGER ,
eventListTrap INTEGER ,
eventListSyslogMessage DisplayString,
eventListCustomMessage DisplayString,
eventListIntegerElements DisplayString,
eventListStringElements DisplayString,
eventListCliScript DisplayString
}
eventListIndex OBJECT-TYPE
SYNTAX INTEGER (0..127)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Automatically generated"
::= { eventListEntry 1 }
eventListName OBJECT-TYPE -- name
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Name of the event"
::= { eventListEntry 2 }
eventListGroup OBJECT-TYPE -- group
SYNTAX INTEGER
{
internal (0),
debug (2),
test (3),
reset (4),
firmware (5),
system (6),
config (7),
login (8),
auth (9),
power (10),
temperature (11),
link (12),
sfp (13),
poe (14),
ring (15),
ntp (16),
signals (17),
script (18),
filter (19),
lacp (20),
app (21),
cable (22),
security (23),
msp1000 (24),
backup (25),
fan (26),
messaging (27),
terminalServer (28),
smartOffice (29)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Associated group of this event"
::= { eventListEntry 3 }
eventListRelevance OBJECT-TYPE -- relevance
SYNTAX INTEGER
{
pos (0),
neg (1),
info (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Positive, negative or informational event"
::= { eventListEntry 4 }
eventListInternal OBJECT-TYPE -- internal
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If enabled this event cannot be used for syslog or traps"
::= { eventListEntry 5 }
eventListSeverity OBJECT-TYPE -- severity
SYNTAX INTEGER
{
disabled (0),
debug (1),
info (2),
notice (3),
warning (4),
error (5),
critical (6),
alert (7),
emergency (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Severity level of this event. Can be modified if required"
::= { eventListEntry 6 }
eventListSource OBJECT-TYPE -- source
SYNTAX INTEGER
{
unit (0),
port (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unit or port related event"
::= { eventListEntry 7 }
eventListTrap OBJECT-TYPE -- trap
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When enabled a trap may be generated for this event"
::= { eventListEntry 8 }
eventListSyslogMessage OBJECT-TYPE -- syslog_message
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Fixed event text describing the cause of the event."
::= { eventListEntry 9 }
eventListCustomMessage OBJECT-TYPE -- custom_message
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Here a custom or translated version of the event text may be inserted."
::= { eventListEntry 10 }
eventListIntegerElements OBJECT-TYPE -- integer_elements
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lists which integer value informations are available for the syslog message"
::= { eventListEntry 11 }
eventListStringElements OBJECT-TYPE -- string_elements
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lists which string type informations are available for the syslog message"
::= { eventListEntry 12 }
eventListCliScript OBJECT-TYPE -- cli_script
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When a script name is present the script will be executed whenever this event occurs. Note: Internal events do not trigger scripts even though a script name may be entered. Several scripts may be assigned to a single event. Syntax: app/scriptfile:subroutine para1 para2, next script... All fields besides the scriptfile are optional."
::= { eventListEntry 13 }
-- ********************* End of eventListTable ***********************
-- ****************************** STATUS SECTION ********************************
END