-- Copyright (C) 2010 by HUAWEI TECHNOLOGIES. All rights reserved.
|
|
-- Description: The MIB module defines Huawei's SPC management MIB objects.
|
|
-- Reference:
|
|
-- Version: V3.13
|
|
-- ============================================================================
|
|
HUAWEI-SPC-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
huaweiUtility
|
|
FROM HUAWEI-MIB
|
|
Integer32, IpAddress, OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
RowStatus
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
|
|
hwSpc MODULE-IDENTITY
|
|
LAST-UPDATED "201009030000Z"
|
|
ORGANIZATION "Huawei Technologies Co.,Ltd."
|
|
CONTACT-INFO
|
|
"Huawei Industrial Base
|
|
Bantian, Longgang
|
|
Shenzhen 518129
|
|
People's Republic of China
|
|
Website: http://www.huawei.com
|
|
Email: support@huawei.com
|
|
"
|
|
DESCRIPTION
|
|
"The MIB module defines Huawei's SPC management MIB objects.
|
|
"
|
|
|
|
-- Revision history
|
|
REVISION "201303280000Z"
|
|
DESCRIPTION "V1.32, modify the value range of hwIpSpcAttributeVoiceCode,hwIpSpcAttributeVoiceCode,hwIpSpcAttributeEce,
|
|
hwIpSpcAttributeSce,hwIpSpcAttributeRtpInterval,hwIpSpcAttributePlc,
|
|
hwIpSpcAttributeRfc2198,hwIpSpcAttributeJbMode,hwIpSpcAttributeWorkMode,
|
|
hwIpSpcAttributeStreamMode,hwRemotePortStepNum in hwSpcMngtTable."
|
|
REVISION "201302170000Z"
|
|
DESCRIPTION "V3.13, added hwIpSpcMinUdp, hwIpSpcMaxUdp to hwSpcMibObjects."
|
|
|
|
REVISION "201009030000Z"
|
|
DESCRIPTION "V3.12, corrected error descriptions."
|
|
|
|
REVISION "201007030000Z"
|
|
DESCRIPTION "V3.11, corrected errors."
|
|
|
|
REVISION "201005280000Z"
|
|
DESCRIPTION "V3.10, corrected the update date."
|
|
|
|
REVISION "201004100000Z"
|
|
DESCRIPTION "V3.09, corrected the enumerate name."
|
|
|
|
REVISION "201003220000Z"
|
|
DESCRIPTION "V3.08, corrected test errors."
|
|
|
|
REVISION "201001260000Z"
|
|
DESCRIPTION "V3.06, added trap notification and corrected compile errors."
|
|
|
|
REVISION "200907030000Z"
|
|
DESCRIPTION "V3.05, added value range of hwIpSpcAttributeVoiceCode to support G.722 and G.726 codec."
|
|
|
|
::= { huaweiUtility 15 }
|
|
|
|
|
|
hwSpcMibObjects OBJECT IDENTIFIER ::= { hwSpc 1 }
|
|
|
|
hwSpcMngtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwSpcMngtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"You can add, delete, modify or query SPC using hwSpcMngtTable.
|
|
The index of this table is hwSpcNo.
|
|
"
|
|
::= { hwSpcMibObjects 1 }
|
|
|
|
hwSpcMngtEntry OBJECT-TYPE
|
|
SYNTAX HwSpcMngtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"You can add, delete, modify or query SPC using hwSpcMngtTable.
|
|
The index of this entry is hwSpcNo.
|
|
"
|
|
INDEX { hwSpcNo }
|
|
::= { hwSpcMngtTable 1 }
|
|
|
|
HwSpcMngtEntry ::=
|
|
SEQUENCE {
|
|
hwSpcNo
|
|
Integer32,
|
|
hwStartFrameID
|
|
Integer32,
|
|
hwStartSlotID
|
|
Integer32,
|
|
hwStartPort
|
|
Integer32,
|
|
hwStartBsn
|
|
Integer32,
|
|
hwEndFrameID
|
|
Integer32,
|
|
hwEndSlotID
|
|
Integer32,
|
|
hwEndPort
|
|
Integer32,
|
|
hwEndBsn
|
|
Integer32,
|
|
hwChannelNum
|
|
Integer32,
|
|
hwApptype
|
|
INTEGER,
|
|
hwSpctype
|
|
INTEGER,
|
|
hwStartPortSubType
|
|
INTEGER,
|
|
hwEndPortSubType
|
|
INTEGER,
|
|
hwPathProtect
|
|
INTEGER,
|
|
hwSPCName
|
|
OCTET STRING,
|
|
hwSpcState
|
|
INTEGER,
|
|
hwFailCause
|
|
INTEGER,
|
|
hwOprType
|
|
INTEGER,
|
|
hwRowStatus
|
|
RowStatus,
|
|
hwStartCESFrame
|
|
Integer32,
|
|
hwStartCESSlot
|
|
Integer32,
|
|
hwStartCESPort
|
|
Integer32,
|
|
hwStartUpPv8Frame
|
|
Integer32,
|
|
hwStartUpPv8Slot
|
|
Integer32,
|
|
hwStartUpPv8Port
|
|
Integer32,
|
|
hwStartDownPv8Frame
|
|
Integer32,
|
|
hwStartDownPv8Slot
|
|
Integer32,
|
|
hwStartDownPv8Port
|
|
Integer32,
|
|
hwStartRspFrame
|
|
Integer32,
|
|
hwStartRspSlot
|
|
Integer32,
|
|
hwStartRspPort
|
|
Integer32,
|
|
hwEndtCESFrame
|
|
Integer32,
|
|
hwEndCESSlot
|
|
Integer32,
|
|
hwEndCESPort
|
|
Integer32,
|
|
hwEndUpPv8Frame
|
|
Integer32,
|
|
hwEndUpPv8Slot
|
|
Integer32,
|
|
hwEndUpPv8Port
|
|
Integer32,
|
|
hwEndDownPv8Frame
|
|
Integer32,
|
|
hwEndDownPv8Slot
|
|
Integer32,
|
|
hwEndDownPv8Port
|
|
Integer32,
|
|
hwEndRspFrame
|
|
Integer32,
|
|
hwEndRspSlot
|
|
Integer32,
|
|
hwEndRspPort
|
|
Integer32,
|
|
hwIpSpcAttributeLocalIPAddr
|
|
IpAddress,
|
|
hwIpSpcAttributeLocalPort
|
|
Integer32,
|
|
hwIpSpcAttributeRemoteIPAddr
|
|
IpAddress,
|
|
hwIpSpcAttributeRemotePort
|
|
Integer32,
|
|
hwIpSpcAttributeVoiceCode
|
|
INTEGER,
|
|
hwIpSpcAttributeEce
|
|
INTEGER,
|
|
hwIpSpcAttributeSce
|
|
INTEGER,
|
|
hwIpSpcAttributeRtpInterval
|
|
INTEGER,
|
|
hwIpSpcAttributePlc
|
|
INTEGER,
|
|
hwIpSpcAttributeRfc2198
|
|
INTEGER,
|
|
hwIpSpcAttributeJbMode
|
|
INTEGER,
|
|
hwIpSpcAttributeWorkMode
|
|
INTEGER,
|
|
hwIpSpcAttributeStreamMode
|
|
INTEGER,
|
|
hwRemotePortStepNum
|
|
Integer32,
|
|
hwLinksetNo
|
|
Integer32,
|
|
hwInterfaceID
|
|
Integer32,
|
|
hwConfGroup
|
|
Integer32,
|
|
hwB1DspInfo
|
|
OCTET STRING,
|
|
hwB2DspInfo
|
|
OCTET STRING,
|
|
hwSignalType
|
|
Integer32,
|
|
hwSpcInitialRingType
|
|
Integer32,
|
|
hwSpcCadenceRingType
|
|
Integer32,
|
|
hwSpc2833Payload
|
|
Integer32
|
|
}
|
|
|
|
hwSpcNo OBJECT-TYPE
|
|
SYNTAX Integer32(0..2099)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Index of the SPC
|
|
Range: 0-2047 for MD products and 0-511 for MA products
|
|
"
|
|
::= { hwSpcMngtEntry 1 }
|
|
|
|
hwStartFrameID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..97)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Frame ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSpcMngtEntry 2 }
|
|
|
|
hwStartSlotID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..35)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Slot ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSpcMngtEntry 3 }
|
|
|
|
hwStartPort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..63)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Port ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSpcMngtEntry 4 }
|
|
|
|
hwStartBsn OBJECT-TYPE
|
|
SYNTAX Integer32 (0..31)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Channel index of SPC's start point
|
|
"
|
|
::= { hwSpcMngtEntry 5 }
|
|
|
|
hwEndFrameID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..97|255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Shelf ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
The value 255 indicates that this parameter is not used.
|
|
"
|
|
::= { hwSpcMngtEntry 6 }
|
|
|
|
hwEndSlotID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..35|255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Slot ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
The value 255 indicates that this parameter is not used.
|
|
"
|
|
::= { hwSpcMngtEntry 7 }
|
|
|
|
hwEndPort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..63|255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Port ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
The value 255 indicates that this parameter is not used.
|
|
"
|
|
::= { hwSpcMngtEntry 8 }
|
|
|
|
hwEndBsn OBJECT-TYPE
|
|
SYNTAX Integer32 (0..31|255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Channel index of SPC's end point.
|
|
The value 255 indicates that this parameter is not used.
|
|
"
|
|
::= { hwSpcMngtEntry 9 }
|
|
|
|
hwChannelNum OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Total channels occupied by the SPC.
|
|
"
|
|
::= { hwSpcMngtEntry 10 }
|
|
|
|
|
|
hwApptype OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normal(1), -- normal SPC
|
|
hotline(2), -- hotline SPC
|
|
mChannelTransparent(3), -- M-Channel Transparent SPC
|
|
pBX-extention(4), -- PBX extent SPC
|
|
pBX-bothway(5), -- Bothway SPC
|
|
e1-DDI(6), -- E1-DDI SPC
|
|
t1-DDI(7), -- T1-DDI SPC
|
|
eM-signal(8) -- EM-Signal SPC
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Applied type of SPC.
|
|
Options:
|
|
1. normal(1) -normal application
|
|
2. hotline(2) -hotline application
|
|
3. mChannelTransparent(3) -M channel transparent
|
|
4. pBX-extention(4) -Z interface extension
|
|
5. pBX-bothway(5) -PBX bothway application
|
|
6. e1-DDI(6) -E1 direct dial in
|
|
7. t1-DDI(7) -T1 direct dial in
|
|
8. eM-signal(8) -EM signal application
|
|
"
|
|
::= { hwSpcMngtEntry 11 }
|
|
|
|
hwSpctype OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
anSpc(1), -- Inner SPC
|
|
v5Spc(2), -- V5 SPC
|
|
v5Preconnect(3), -- V5 pre-connection SPC
|
|
private(4), -- Leased line SPC
|
|
ipspc(5), -- IP SPC
|
|
confspc(6) -- conference SPC
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration type of SPC.
|
|
Options:
|
|
1. anSpc(1) -Internal SPC
|
|
2. v5Spc(2) -V5 SPC
|
|
3. v5Preconnect(3) -V5 pre-connection SPC
|
|
4. private(4) -leased line SPC
|
|
5. ipspc(5) -IP SPC
|
|
6. confspc(6) -conference SPC
|
|
"
|
|
::= { hwSpcMngtEntry 12 }
|
|
|
|
hwStartPortSubType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noSubType(255),
|
|
mnt(1),
|
|
mlt(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub type of SPC's start port. If the SPC is used for PHS, the type must be set to mnt or mlt.
|
|
Options:
|
|
1. noSubType(255) -no sub type
|
|
2. mnt(1) -mnt
|
|
3. mlt(2) -mlt
|
|
"
|
|
::= { hwSpcMngtEntry 13 }
|
|
|
|
hwEndPortSubType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noSubType(255),
|
|
mnt(1),
|
|
mlt(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub type of SPC's end port.
|
|
This node is not used on the OLT.
|
|
Options:
|
|
1. noSubType(255) -no sub type
|
|
2. mnt(1) -mnt
|
|
3. mlt(2) -mlt
|
|
"
|
|
::= { hwSpcMngtEntry 14 }
|
|
|
|
hwPathProtect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
yes(1),
|
|
no(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable path protection. This leaf is not used on the OLT.
|
|
Options:
|
|
1. yes(1) -YES
|
|
2. no(2) -NO
|
|
"
|
|
::= { hwSpcMngtEntry 15 }
|
|
|
|
hwSPCName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Name of SPC. It contains 31 characters.
|
|
- means it is not configured.
|
|
"
|
|
::= { hwSpcMngtEntry 16 }
|
|
|
|
hwSpcState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
idle(1),
|
|
normal(2),
|
|
error(3),
|
|
errorChecking(4),
|
|
occupying(5),
|
|
checking(6),
|
|
released(7),
|
|
errReleasing(8),
|
|
refreshReleasing(9),
|
|
disconnecting(10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPC state.
|
|
Options:
|
|
1. idle(1) -idle
|
|
2. normal(2) -normal
|
|
3. error(3) -error
|
|
4. errorChecking(4) -error checking
|
|
5. occupying(5) -occupying
|
|
6. checking(6) -checking
|
|
7. released(7) -released
|
|
8. errReleasing(8) -error releasing
|
|
9. refreshReleasing(9) -refresh releasing
|
|
10. disconnecting(10) -disconnecting
|
|
"
|
|
::= { hwSpcMngtEntry 17 }
|
|
|
|
hwFailCause OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
startBusy(1),
|
|
endBusy(2),
|
|
startFault(3),
|
|
endFault(4),
|
|
startLoop(5),
|
|
endLoop(6),
|
|
startLock(7),
|
|
endLock(8),
|
|
resNotEnough(9),
|
|
waitingTimeout(10),
|
|
startTest(11),
|
|
endTest(12),
|
|
noAlarm(13),
|
|
noTS(14),
|
|
noLicense(15),
|
|
linksetFault(16),
|
|
portUnactive(17)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fault reason of SPC.
|
|
Options:
|
|
1. startBusy(1) -the start port is busy
|
|
2. endBusy(2) - the end port is busy
|
|
3. startFault(3) - the start port is fault
|
|
4. endFault(4) - the end port is fault
|
|
5. startLoop(5) - the start port is looped
|
|
6. endLoop(6) - the end port is looped
|
|
7. startLock(7) - the start port is locked
|
|
8. endLock(8) - the end port is locked
|
|
9. resNotEnough(9) -the system resource is not enough
|
|
10. waitingTimeout(10) -the waiting timer times out
|
|
11. startTest(11) -the start port is testing
|
|
12. endTest(12) -the end port is testing
|
|
13. noAlarm(13) -no alarm
|
|
14. noTS(14) -no TS
|
|
15. noLicense(15) -no license
|
|
16. linksetFault(16) -link set fault
|
|
17. portUnactive(17) -port unactive
|
|
"
|
|
::= { hwSpcMngtEntry 18 }
|
|
|
|
hwOprType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noOperation(1), -- No operation
|
|
connect(2), -- Connect
|
|
disconnect(3) -- Disconnect
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operate type of SPC. It can be set to disconnect or connect.
|
|
Options:
|
|
1. noOperation(1) -no operation
|
|
2. connect(2) -connect
|
|
3. disconnect(3) -disconnect
|
|
"
|
|
::= { hwSpcMngtEntry 19 }
|
|
|
|
hwRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Row status. It supports only CreateAndGo(4) and Destroy(6).
|
|
"
|
|
::= { hwSpcMngtEntry 20 }
|
|
|
|
hwStartCESFrame OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start CES shelf.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 21 }
|
|
|
|
hwStartCESSlot OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CES slot.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 22 }
|
|
|
|
hwStartCESPort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start CES port.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 23 }
|
|
|
|
hwStartUpPv8Frame OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start upstream PV8 shelf.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 24 }
|
|
|
|
hwStartUpPv8Slot OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start upstream PV8 slot.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 25 }
|
|
|
|
hwStartUpPv8Port OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start upstream PV8 port.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 26 }
|
|
|
|
hwStartDownPv8Frame OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start downstream PV8 shelf.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 27 }
|
|
|
|
hwStartDownPv8Slot OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start downstream PV8 slot.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 28 }
|
|
|
|
hwStartDownPv8Port OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start downstream PV8 port.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 29 }
|
|
|
|
hwStartRspFrame OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start downstream RSP shelf.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 30 }
|
|
|
|
hwStartRspSlot OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start downstream RSP slot.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 31 }
|
|
|
|
hwStartRspPort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Start downstream RSP port.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 32 }
|
|
|
|
hwEndtCESFrame OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End downstream CES shelf.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 33 }
|
|
|
|
hwEndCESSlot OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End downstream CES slot.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 34 }
|
|
|
|
hwEndCESPort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End CES port.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 35 }
|
|
|
|
hwEndUpPv8Frame OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End upstream PV8 shelf.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 36 }
|
|
|
|
hwEndUpPv8Slot OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End upstream PV8 slot.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 37 }
|
|
|
|
hwEndUpPv8Port OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End upstream PV8 port.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 38 }
|
|
|
|
hwEndDownPv8Frame OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End downstream PV8 shelf.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 39 }
|
|
|
|
hwEndDownPv8Slot OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End downstream PV8 slot.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 40 }
|
|
|
|
hwEndDownPv8Port OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End downstream PV8 port.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 41 }
|
|
|
|
hwEndRspFrame OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End RSP shelf.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 42 }
|
|
|
|
hwEndRspSlot OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End RSP slot.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 43 }
|
|
|
|
hwEndRspPort OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End RSP port.
|
|
If the value is 255, it indicates that the SPC does not use this path.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 44 }
|
|
|
|
hwIpSpcAttributeLocalIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Local IP address of the SPC. If the SPC's type is IPSPC, the local IP address must be configured.
|
|
"
|
|
::= { hwSpcMngtEntry 45 }
|
|
|
|
hwIpSpcAttributeLocalPort OBJECT-TYPE
|
|
SYNTAX Integer32(0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Local UDP port of the SPC. If the SPC's type is IPSPC, the local UDP port must be configured.
|
|
"
|
|
::= { hwSpcMngtEntry 46 }
|
|
|
|
hwIpSpcAttributeRemoteIPAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote IP address of the SPC. If the SPC's type is IPSPC, the remote IP address mustd be configured.
|
|
"
|
|
::= { hwSpcMngtEntry 47 }
|
|
|
|
hwIpSpcAttributeRemotePort OBJECT-TYPE
|
|
SYNTAX Integer32(0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote UDP port of the SPC. If the SPC's type is IPSPC, the remote UDP port must be configured.
|
|
"
|
|
::= { hwSpcMngtEntry 48 }
|
|
|
|
hwIpSpcAttributeVoiceCode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
acG711Malaw(1), -- G.711A
|
|
acG711Mulaw(2), -- G.711U
|
|
acG723Low(3), -- G.723low
|
|
acG723High(4), -- G.723high
|
|
acG729(5), -- G.729
|
|
clearMode(6), -- clear mode
|
|
g72616k(7), -- G.726_16K
|
|
g72624k(8), -- G.726_24K
|
|
g72632k(9), -- G.726_32K
|
|
g72640k(10), -- G.726_40K
|
|
g722(11), -- G.722
|
|
invalid(-1) -- invalid value
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voice codec type of the SPC.
|
|
Options:
|
|
1. acG711Malaw(1) -G.711A
|
|
2. acG711Mulaw(2) -G.711U
|
|
3. acG723Low(3) -G.723low
|
|
4. acG723High(4) -G.723high
|
|
5. acG729(5) -G.729
|
|
6. clearMode(6) -clear mode
|
|
7. g72616k(7) -G.726_16K
|
|
8. g72624k(8) -G.726_24K
|
|
9. g72632k(9) -G.726_32K
|
|
10. g72640k(10) -G.726_40K
|
|
11. g722(11) -G.722
|
|
12. invalid(-1) -invalid value
|
|
"
|
|
::= { hwSpcMngtEntry 49 }
|
|
|
|
hwIpSpcAttributeEce OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disable(1),
|
|
enable(2),
|
|
invalid(-1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The switch of EC.
|
|
Options:
|
|
1. disable(1) -disable EC
|
|
2. enable(2) -enable EC
|
|
3. invalid(-1) -invalid value
|
|
"
|
|
::= { hwSpcMngtEntry 50 }
|
|
|
|
hwIpSpcAttributeSce OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disable(1),
|
|
enable(2),
|
|
invalid(-1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The switch of SC.
|
|
Options:
|
|
1. disable(1) -disable SC
|
|
2. enable(2) -enable SC
|
|
3. invalid(-1) -invalid value
|
|
"
|
|
::= { hwSpcMngtEntry 51 }
|
|
|
|
hwIpSpcAttributeRtpInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
five(1),
|
|
ten(2),
|
|
twenty(3),
|
|
thirty(4),
|
|
invalid(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RTP sampling time.
|
|
Options:
|
|
1. five(1) -5 ms
|
|
2. ten(2) -10 ms
|
|
3. twenty(3) -20 ms
|
|
4. thirty(4) -30 ms
|
|
5. invalid(255) -invalid value
|
|
Unit: millisecond
|
|
"
|
|
::= { hwSpcMngtEntry 52}
|
|
|
|
hwIpSpcAttributePlc OBJECT-TYPE
|
|
SYNTAX INTEGER{ enable(1),disable(2),invalid(255)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The switch of PLC.
|
|
Options:
|
|
1. enable(1) -enable PLC
|
|
2. disable(2) -disable PLC
|
|
3. invalid(255) -invalid value
|
|
"
|
|
::= { hwSpcMngtEntry 53}
|
|
|
|
hwIpSpcAttributeRfc2198 OBJECT-TYPE
|
|
SYNTAX INTEGER{ enable(1),disable(2),invalid(255)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The switch of 2198.
|
|
Options:
|
|
1. enable(1) -enable RFC2198 redundancy
|
|
2. disable(2) -disable RFC2198 redundancy
|
|
3. invalid(255) -invalid value
|
|
"
|
|
::= { hwSpcMngtEntry 54}
|
|
|
|
hwIpSpcAttributeJbMode OBJECT-TYPE
|
|
SYNTAX INTEGER{ adapt(1),fixed(2),invalid(255)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Jitterbuffer mode.
|
|
Options:
|
|
1. adapt(1) -adapt
|
|
2. fixed(2) -fixed
|
|
3. invalid(255) -invalid value
|
|
"
|
|
::= { hwSpcMngtEntry 55}
|
|
|
|
hwIpSpcAttributeWorkMode OBJECT-TYPE
|
|
SYNTAX INTEGER{ voice(1),fax(2),modem(3),invalid(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
DSP work mode.
|
|
Options:
|
|
1. voice(1) -voice
|
|
2. fax(2) -fax
|
|
3. modem(3) -modem
|
|
4. invalid(255) -invalid value
|
|
"
|
|
::= { hwSpcMngtEntry 56}
|
|
|
|
hwIpSpcAttributeStreamMode OBJECT-TYPE
|
|
SYNTAX INTEGER{ sendReceive(1),sendOnly(2),receiveOnly(3),invalid(255) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Connect mode.
|
|
Options:
|
|
1. sendReceive(1) -send and receive
|
|
2. sendOnly(2) -send only
|
|
3. receiveOnly(3) -receive only
|
|
4. invalid(255) -invalid value
|
|
"
|
|
::= { hwSpcMngtEntry 57}
|
|
|
|
hwRemotePortStepNum OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65534|65535)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The remote-port step. If the value is 65535, the ANSPC does not use the remote port step number attribute.
|
|
"
|
|
::= { hwSpcMngtEntry 58 }
|
|
|
|
hwLinksetNo OBJECT-TYPE
|
|
SYNTAX Integer32 (0..31|-1)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
IUA link set number.
|
|
In the case of the U interface transparent, this parameter must be configured.
|
|
If the value is -1, it indicates that the SPC does not use the IUA link set number.
|
|
"
|
|
::= { hwSpcMngtEntry 59 }
|
|
|
|
hwInterfaceID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535|-1)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
IUA interface ID.
|
|
In the case of the U interface transparent, this parameter must be configured.
|
|
If the value is -1, it indicates that the SPC does not use the IUA interface ID.
|
|
"
|
|
::= { hwSpcMngtEntry 60 }
|
|
|
|
hwConfGroup OBJECT-TYPE
|
|
SYNTAX Integer32 (0..15)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Conference Group ID.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 61 }
|
|
|
|
hwB1DspInfo OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (9..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Information of B1 DSP in conference service or BRA IP service.
|
|
It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID.
|
|
This leaf is not used on the OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 62 }
|
|
|
|
hwB2DspInfo OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (9..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Information of B2 DSP in BRA ip service.
|
|
It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID
|
|
This leaf is not used on OLT.
|
|
"
|
|
::= { hwSpcMngtEntry 63 }
|
|
|
|
hwSignalType OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Signal type of IP SPC.
|
|
Options:
|
|
1. 1 - normal
|
|
2. 2 - 2833
|
|
This leaf is only used on the UA5000.
|
|
"
|
|
::= { hwSpcMngtEntry 64}
|
|
|
|
hwSpcInitialRingType OBJECT-TYPE
|
|
SYNTAX Integer32 (1..27)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP SPC initial ring type.
|
|
Enumeration type:
|
|
1-Null, 2-Normal ring (FSK) 1:4, 3-Special ring (FSK) 1:2, 4-Special ring (FSK) 0.4:0.2:0.4:4, 5-Special ring (FSK) 1.2:2, 6-HK ring (FSK) 1:3, 7-HK CNTRX (FSK) 0.4:0.2:0.4:0.2:0.4:3.0,
|
|
8-HK DN-A (FSK) 0.4:0.2:0.4:3.0, 9-HK DN-B (FSK) 1.2:3, 10-CNTRX-IN (FSK) 0.4:0.2:0.4:0.2:0.4:2.6, 11-Egypt long-distance ring (FSK) 2:1, 12-user defined FSK ring mode 0,
|
|
13-user defined FSK ring mode 1, 14-user defined FSK ring mode 2, 15-user defined FSK ring mode 3, 16-user defined FSK ring mode 4, 17-user defined FSK ring mode 5,
|
|
18-user defined FSK ring mode 6, 19-user defined FSK ring mode 7, 20-user defined FSK ring mode 8, 21-user defined FSK ring mode 9, 22-user defined FSK ring mode 10,
|
|
23-user defined FSK ring mode 11, 24-user defined FSK ring mode 12, 25-user defined FSK ring mode 13, 26-user defined FSK ring mode 14, 27-user defined FSK ring mode 15
|
|
This leaf is only used on the UA5000.
|
|
"
|
|
::= { hwSpcMngtEntry 65 }
|
|
|
|
hwSpcCadenceRingType OBJECT-TYPE
|
|
SYNTAX Integer32 (1..30)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP SPC cadence ring type.
|
|
Enumerated types:
|
|
1-Null, 2-Normal ring 1:4, 3-Special ring 1:2, 4-Special ring 0.4:0.2:0.4:4, 5-Long ring, 6-Special ring 1.2:2, 7-HK ring 1:3, 8-HK CNTRX 0.4:0.2:0.4:0.2:0.4:3.0,
|
|
9-HK DN-A 0.4:0.2:0.4:3.0, 10-HK ACB 0.4:0.2, 11-HK reminder ring (one tone every 0.4 second; one tone), 12-HK DN-B 1.2:3, 13-CNTRX-IN 0.4:0.2:0.4:0.2:0.4:2.6,
|
|
14-Egypt long-distance ring 2:1, 15-user defined ring mode 0, 16-user defined ring mode 1, 17-user defined ring mode 2, 18-user defined ring mode 3,
|
|
19-user defined ring mode 4, 20-user defined ring mode 5, 21-user defined ring mode 6, 22-user defined ring mode 7, 23-user defined ring mode 8, 24-user defined ring mode 9,
|
|
25-user defined ring mode 10, 26-user defined ring mode 11, 27-user defined ring mode 12, 28-user defined ring mode 13, 29-user defined ring mode 14,
|
|
30-user defined ring mode 15
|
|
This leaf is only used on the UA5000.
|
|
"
|
|
::= { hwSpcMngtEntry 66 }
|
|
|
|
hwSpc2833Payload OBJECT-TYPE
|
|
SYNTAX Integer32 (96..127)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP SPC 2833 payload type.
|
|
This leaf is only used on the UA5000.
|
|
"
|
|
::= { hwSpcMngtEntry 67 }
|
|
|
|
hwNextAllocSpcNo OBJECT-TYPE
|
|
SYNTAX Integer32(0..2099)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Next valid allocation of SPC index
|
|
Range: 0-2047 for MD products and 0-511 for MA products.
|
|
"
|
|
::= { hwSpcMibObjects 3 }
|
|
|
|
hwSpcProtectGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwSpcProtectGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"You can add, delete, modify or query SPC protect group using hwSpcProtectGroupTable.
|
|
The index of this table is hwSpcProtectGroupID.
|
|
"
|
|
::= { hwSpcMibObjects 4 }
|
|
|
|
hwSpcProtectGroupEntry OBJECT-TYPE
|
|
SYNTAX HwSpcProtectGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"You can add, delete, modify or query SPC protect group using hwSpcProtectGroupTable.
|
|
The index of this entry is hwSpcProtectGroupID.
|
|
"
|
|
INDEX { hwSpcProtectGroupID }
|
|
::= { hwSpcProtectGroupTable 1 }
|
|
|
|
HwSpcProtectGroupEntry ::=
|
|
SEQUENCE {
|
|
hwSpcProtectGroupID
|
|
Integer32,
|
|
hwSpcMainPortFrameID
|
|
Integer32,
|
|
hwSpcMainPortSlotID
|
|
Integer32,
|
|
hwSpcMainPortPortID
|
|
Integer32,
|
|
hwProtectGroupRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
hwSpcProtectGroupID OBJECT-TYPE
|
|
SYNTAX Integer32(0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Index of the SPC E1 protect group.
|
|
Range: 0-2 for UA products.
|
|
"
|
|
::= { hwSpcProtectGroupEntry 1 }
|
|
|
|
hwSpcMainPortFrameID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..97)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Frame ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSpcProtectGroupEntry 2 }
|
|
|
|
hwSpcMainPortSlotID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..35)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Slot ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSpcProtectGroupEntry 3 }
|
|
|
|
hwSpcMainPortPortID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Port ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSpcProtectGroupEntry 4 }
|
|
|
|
hwProtectGroupRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Row status. It supports only CreateAndGo(4) and Destroy(6).
|
|
"
|
|
::= { hwSpcProtectGroupEntry 5 }
|
|
|
|
hwSpcProtectTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwSpcProtectEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"You can add, delete, modify or query SPC protect link using hwSpcProtectTable.
|
|
The index of this table is hwSpcProtectID.
|
|
"
|
|
::= { hwSpcMibObjects 5 }
|
|
|
|
hwSpcProtectEntry OBJECT-TYPE
|
|
SYNTAX HwSpcProtectEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"You can add, delete, modify or query SPC protect link using hwSpcProtectTable.
|
|
The index of this entry is hwSpcProtectID.
|
|
"
|
|
INDEX { hwSpcProtectID }
|
|
::= { hwSpcProtectTable 1 }
|
|
|
|
HwSpcProtectEntry ::=
|
|
SEQUENCE {
|
|
hwSpcProtectID
|
|
Integer32,
|
|
hwSpcProtectGroupId
|
|
Integer32,
|
|
hwSpcProtectPortFrameID
|
|
Integer32,
|
|
hwSpcProtectPortSlotID
|
|
Integer32,
|
|
hwSpcProtectPortPortID
|
|
Integer32,
|
|
hwSpcProtectPriority
|
|
Integer32,
|
|
hwSpcProtectUsedFlag
|
|
Integer32,
|
|
hwProtectLinkRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
hwSpcProtectID OBJECT-TYPE
|
|
SYNTAX Integer32(0..8)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Index of the SPC E1 protect link.
|
|
Range: 0-8 for UA products.
|
|
"
|
|
::= { hwSpcProtectEntry 1 }
|
|
|
|
hwSpcProtectGroupId OBJECT-TYPE
|
|
SYNTAX Integer32(0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Index of the SPC E1 protect group.
|
|
"
|
|
::= { hwSpcProtectEntry 2 }
|
|
|
|
hwSpcProtectPortFrameID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..97)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Frame ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSpcProtectEntry 3 }
|
|
|
|
hwSpcProtectPortSlotID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..35)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Slot ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSpcProtectEntry 4 }
|
|
|
|
hwSpcProtectPortPortID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Port ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSpcProtectEntry 5 }
|
|
|
|
hwSpcProtectPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (1..3)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Priority of SPC E1 protect link. 1: cat1(1), 2: cat1(2), 3: cat1(3).
|
|
"
|
|
::= { hwSpcProtectEntry 6 }
|
|
|
|
hwSpcProtectUsedFlag OBJECT-TYPE
|
|
SYNTAX Integer32(1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
State of the SPC E1 protect link.
|
|
"
|
|
::= { hwSpcProtectEntry 7 }
|
|
|
|
hwProtectLinkRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Row status. It supports only CreateAndGo(4) and Destroy(6).
|
|
"
|
|
::= { hwSpcProtectEntry 8 }
|
|
|
|
-- start: add for scs
|
|
hwSubRateSwitchTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HwSubRateSwitchEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"You can add, delete, modify or query sub-rate switch using hwSubRateSwitchTable.
|
|
The index of this table is hwSubRateSwitchID.
|
|
"
|
|
::= { hwSpcMibObjects 6 }
|
|
|
|
hwSubRateSwitchEntry OBJECT-TYPE
|
|
SYNTAX HwSubRateSwitchEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"You can add, delete, modify or query sub-rate switch using hwSubRateSwitchTable.
|
|
The index of this entry is hwSubRateSwitchID.
|
|
"
|
|
INDEX { hwSubRateSwitchID }
|
|
::= { hwSubRateSwitchTable 1 }
|
|
|
|
HwSubRateSwitchEntry ::=
|
|
SEQUENCE {
|
|
hwSubRateSwitchID
|
|
Integer32,
|
|
hwSubRateSwitchStartFrameID
|
|
Integer32,
|
|
hwSubRateSwitchStartSlotID
|
|
Integer32,
|
|
hwSubRateSwitchStartPortID
|
|
Integer32,
|
|
hwSubRateSwitchStartChannelID
|
|
Integer32,
|
|
hwSubRateSwitchStartSubChannelID
|
|
Integer32,
|
|
hwSubRateSwitchEndFrameID
|
|
Integer32,
|
|
hwSubRateSwitchEndSlotID
|
|
Integer32,
|
|
hwSubRateSwitchEndPortID
|
|
Integer32,
|
|
hwSubRateSwitchEndChannelID
|
|
Integer32,
|
|
hwSubRateSwitchEndSubChannelID
|
|
Integer32,
|
|
hwSubRateSwitchState
|
|
INTEGER,
|
|
hwSubRateSwitchRowStatus
|
|
RowStatus
|
|
}
|
|
|
|
hwSubRateSwitchID OBJECT-TYPE
|
|
SYNTAX Integer32(0..1023)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Index of the sub-rate switch
|
|
"
|
|
::= { hwSubRateSwitchEntry 1 }
|
|
|
|
hwSubRateSwitchStartFrameID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..97)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Frame ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSubRateSwitchEntry 2 }
|
|
|
|
hwSubRateSwitchStartSlotID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..35)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Slot ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSubRateSwitchEntry 3 }
|
|
|
|
hwSubRateSwitchStartPortID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..31)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Port ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSubRateSwitchEntry 4 }
|
|
|
|
hwSubRateSwitchStartChannelID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..31)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Channel index of sub-rate switch start point
|
|
"
|
|
::= { hwSubRateSwitchEntry 5 }
|
|
|
|
hwSubRateSwitchStartSubChannelID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..19)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
sub-rate channel index of sub-rate switch start point
|
|
"
|
|
::= { hwSubRateSwitchEntry 6 }
|
|
|
|
hwSubRateSwitchEndFrameID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..97)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Frame ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSubRateSwitchEntry 7 }
|
|
|
|
hwSubRateSwitchEndSlotID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..35)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Slot ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSubRateSwitchEntry 8 }
|
|
|
|
hwSubRateSwitchEndPortID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..31)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Port ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB.
|
|
"
|
|
::= { hwSubRateSwitchEntry 9 }
|
|
|
|
hwSubRateSwitchEndChannelID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..31)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Channel index of sub-rate switch end point.
|
|
"
|
|
::= { hwSubRateSwitchEntry 10 }
|
|
|
|
hwSubRateSwitchEndSubChannelID OBJECT-TYPE
|
|
SYNTAX Integer32 (0..19)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
sub-rate channel index of sub-rate switch end point.
|
|
"
|
|
::= { hwSubRateSwitchEntry 11 }
|
|
|
|
hwSubRateSwitchState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fault(1),
|
|
normal(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sub-rate switch state.
|
|
Options:
|
|
1. fault(1) -fault
|
|
2. normal(2) -normal
|
|
"
|
|
::= { hwSubRateSwitchEntry 12 }
|
|
|
|
hwSubRateSwitchRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Row status. It supports only CreateAndGo(4) and Destroy(6).
|
|
"
|
|
::= { hwSubRateSwitchEntry 13 }
|
|
|
|
hwNextAllocSubRateSwitchID OBJECT-TYPE
|
|
SYNTAX Integer32(0..1023)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Next valid allocation of SubRateSwitch index
|
|
Range: 0-1023.
|
|
"
|
|
::= { hwSpcMibObjects 7 }
|
|
|
|
hwIpSpcMinUdp OBJECT-TYPE
|
|
SYNTAX Integer32(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Start UDP port of IPSPC.
|
|
Range: 0-65535.
|
|
"
|
|
::= { hwSpcMibObjects 8 }
|
|
|
|
hwIpSpcMaxUdp OBJECT-TYPE
|
|
SYNTAX Integer32(0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
End UDP port of IPSPC.
|
|
Range: 0-65535.
|
|
"
|
|
::= { hwSpcMibObjects 9 }
|
|
-- end: add for scs
|
|
|
|
hwSpcMibTrap OBJECT IDENTIFIER ::= { hwSpc 2 }
|
|
|
|
hwSpcTrapOid OBJECT IDENTIFIER ::= { hwSpcMibTrap 1 }
|
|
|
|
hwSpcTrapsDefine OBJECT IDENTIFIER ::= { hwSpcMibTrap 2 }
|
|
|
|
hwSpcTraps OBJECT IDENTIFIER ::= { hwSpcTrapsDefine 0 }
|
|
|
|
hwSpcMibCompance OBJECT IDENTIFIER ::= { hwSpc 3 }
|
|
|
|
hwIASSpcTrapsVbOids OBJECT IDENTIFIER ::= { hwSpc 4 }
|
|
|
|
hwIASSpcTraps OBJECT IDENTIFIER ::= { hwSpc 5 }
|
|
|
|
hwIASSpcCommonTraps OBJECT IDENTIFIER ::= { hwIASSpcTraps 1 }
|
|
|
|
hwIASSpcAlarmTraps OBJECT IDENTIFIER ::= { hwIASSpcTraps 2 }
|
|
|
|
------ /* Start hwIASSpcTrapsVbOids */
|
|
|
|
hwIASSpcBChn OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..32)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Indicates the B-channel.
|
|
"
|
|
::= { hwIASSpcTrapsVbOids 1 }
|
|
|
|
hwIASSpcDspFrame OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..255)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Indicate the shelf ID of a DSP resource board.
|
|
"
|
|
::= { hwIASSpcTrapsVbOids 2 }
|
|
|
|
hwIASSpcDspSlot OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..255)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Indicate the slot ID of a DSP resource board.
|
|
"
|
|
::= { hwIASSpcTrapsVbOids 3 }
|
|
|
|
hwIASSpcDspSub OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..255)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Indicate the DSP sub-board ID of a resource board.
|
|
"
|
|
::= { hwIASSpcTrapsVbOids 4 }
|
|
|
|
hwIASSpcDspChannel OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..65535)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Indicate the DSP inner channel ID of a subboard.
|
|
"
|
|
::= { hwIASSpcTrapsVbOids 5 }
|
|
|
|
hwIASSpcDspLoopdelay OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967295)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Indicate the DSP loop delay.
|
|
"
|
|
::= { hwIASSpcTrapsVbOids 6 }
|
|
|
|
hwIASSpcDspFractionLost OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967295)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Indicate the DSP fractionLost.
|
|
"
|
|
::= { hwIASSpcTrapsVbOids 7 }
|
|
|
|
hwIASSpcDspJitter OBJECT-TYPE
|
|
SYNTAX Unsigned32(0..4294967295)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
The DSP jitter.
|
|
"
|
|
::= { hwIASSpcTrapsVbOids 8 }
|
|
|
|
hwIASSpcOperateType OBJECT-TYPE
|
|
SYNTAX INTEGER{ add(0), delete(1), modify(2), release(3), undorelease(4), dspconfig(5) }
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Indicate the operate type on a SPC.
|
|
Options:
|
|
1. add(0) -add spc link
|
|
2. delete(1) -delete spc link
|
|
3. modify(2) -modify spc link
|
|
4. release(3) -spc link end service
|
|
5. undorelease(4) -spc link start service
|
|
6. dspconfig(5) -config spc link dsp parameters
|
|
"
|
|
::= { hwIASSpcTrapsVbOids 9 }
|
|
|
|
------ /* End hwIASSpcTrapsVbOids */
|
|
|
|
------ /* Start hwIASSpcCommonTraps */
|
|
hwIASSpcOperateTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwSpcNo,hwIASSpcOperateType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This notification indicates that the operation on the SPC.
|
|
"
|
|
::= { hwIASSpcCommonTraps 0 1 }
|
|
------ /* End hwIASSpcCommonTraps */
|
|
|
|
------ /* Start hwIASSpcAlarmTraps */
|
|
|
|
hwIASSpcFaultTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwSpcNo }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This notification indicates that the SPC is faulty.
|
|
"
|
|
::= { hwIASSpcAlarmTraps 0 1 }
|
|
|
|
hwIASSpcRestoreTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwSpcNo }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This notification indicates that the SPC recovers from a fault.
|
|
"
|
|
::= { hwIASSpcAlarmTraps 0 2 }
|
|
|
|
hwIASSpcReleaseTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwSpcNo }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This notification indicates that the SPC is released.
|
|
"
|
|
::= { hwIASSpcAlarmTraps 0 3 }
|
|
|
|
hwIASSpcConnectTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwSpcNo }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This notification indicates that the SPC is connected again.
|
|
"
|
|
::= { hwIASSpcAlarmTraps 0 4 }
|
|
|
|
hwIASSpcQosExceedTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwSpcNo, hwIASSpcBChn, hwIASSpcDspFrame, hwIASSpcDspSlot, hwIASSpcDspSub, hwIASSpcDspChannel,
|
|
hwIpSpcAttributeRemoteIPAddr, hwIASSpcDspLoopdelay, hwIASSpcDspFractionLost, hwIASSpcDspJitter }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This notification indicates that the value of DSP QoS used by the SPC exceeds the threshold.
|
|
"
|
|
::= { hwIASSpcAlarmTraps 0 5 }
|
|
|
|
hwIASSpcQosRestoreTrap NOTIFICATION-TYPE
|
|
OBJECTS { hwSpcNo, hwIASSpcBChn, hwIASSpcDspFrame, hwIASSpcDspSlot, hwIASSpcDspSub, hwIASSpcDspChannel,
|
|
hwIpSpcAttributeRemoteIPAddr, hwIASSpcDspLoopdelay, hwIASSpcDspFractionLost, hwIASSpcDspJitter }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
This notification indicates that the value of DSP QoS used by the SPC is normal.
|
|
"
|
|
::= { hwIASSpcAlarmTraps 0 6 }
|
|
|
|
------ /* End hwIASSpcAlarmTraps */
|
|
|
|
END
|
|
|