-- ============================================================================ -- Copyright (C) 2010 by HUAWEI TECHNOLOGIES. All rights reserved. -- Description: The MIB module defines Huawei's SPC management MIB objects. -- Reference: -- Version: V3.13 -- ============================================================================ HUAWEI-SPC-MIB DEFINITIONS ::= BEGIN IMPORTS huaweiUtility FROM HUAWEI-MIB Integer32, IpAddress, OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY, Unsigned32 FROM SNMPv2-SMI RowStatus FROM SNMPv2-TC; hwSpc MODULE-IDENTITY LAST-UPDATED "201009030000Z" ORGANIZATION "Huawei Technologies Co.,Ltd." CONTACT-INFO "Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: http://www.huawei.com Email: support@huawei.com " DESCRIPTION "The MIB module defines Huawei's SPC management MIB objects. " -- Revision history REVISION "201303280000Z" DESCRIPTION "V1.32, modify the value range of hwIpSpcAttributeVoiceCode,hwIpSpcAttributeVoiceCode,hwIpSpcAttributeEce, hwIpSpcAttributeSce,hwIpSpcAttributeRtpInterval,hwIpSpcAttributePlc, hwIpSpcAttributeRfc2198,hwIpSpcAttributeJbMode,hwIpSpcAttributeWorkMode, hwIpSpcAttributeStreamMode,hwRemotePortStepNum in hwSpcMngtTable." REVISION "201302170000Z" DESCRIPTION "V3.13, added hwIpSpcMinUdp, hwIpSpcMaxUdp to hwSpcMibObjects." REVISION "201009030000Z" DESCRIPTION "V3.12, corrected error descriptions." REVISION "201007030000Z" DESCRIPTION "V3.11, corrected errors." REVISION "201005280000Z" DESCRIPTION "V3.10, corrected the update date." REVISION "201004100000Z" DESCRIPTION "V3.09, corrected the enumerate name." REVISION "201003220000Z" DESCRIPTION "V3.08, corrected test errors." REVISION "201001260000Z" DESCRIPTION "V3.06, added trap notification and corrected compile errors." REVISION "200907030000Z" DESCRIPTION "V3.05, added value range of hwIpSpcAttributeVoiceCode to support G.722 and G.726 codec." ::= { huaweiUtility 15 } hwSpcMibObjects OBJECT IDENTIFIER ::= { hwSpc 1 } hwSpcMngtTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSpcMngtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "You can add, delete, modify or query SPC using hwSpcMngtTable. The index of this table is hwSpcNo. " ::= { hwSpcMibObjects 1 } hwSpcMngtEntry OBJECT-TYPE SYNTAX HwSpcMngtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "You can add, delete, modify or query SPC using hwSpcMngtTable. The index of this entry is hwSpcNo. " INDEX { hwSpcNo } ::= { hwSpcMngtTable 1 } HwSpcMngtEntry ::= SEQUENCE { hwSpcNo Integer32, hwStartFrameID Integer32, hwStartSlotID Integer32, hwStartPort Integer32, hwStartBsn Integer32, hwEndFrameID Integer32, hwEndSlotID Integer32, hwEndPort Integer32, hwEndBsn Integer32, hwChannelNum Integer32, hwApptype INTEGER, hwSpctype INTEGER, hwStartPortSubType INTEGER, hwEndPortSubType INTEGER, hwPathProtect INTEGER, hwSPCName OCTET STRING, hwSpcState INTEGER, hwFailCause INTEGER, hwOprType INTEGER, hwRowStatus RowStatus, hwStartCESFrame Integer32, hwStartCESSlot Integer32, hwStartCESPort Integer32, hwStartUpPv8Frame Integer32, hwStartUpPv8Slot Integer32, hwStartUpPv8Port Integer32, hwStartDownPv8Frame Integer32, hwStartDownPv8Slot Integer32, hwStartDownPv8Port Integer32, hwStartRspFrame Integer32, hwStartRspSlot Integer32, hwStartRspPort Integer32, hwEndtCESFrame Integer32, hwEndCESSlot Integer32, hwEndCESPort Integer32, hwEndUpPv8Frame Integer32, hwEndUpPv8Slot Integer32, hwEndUpPv8Port Integer32, hwEndDownPv8Frame Integer32, hwEndDownPv8Slot Integer32, hwEndDownPv8Port Integer32, hwEndRspFrame Integer32, hwEndRspSlot Integer32, hwEndRspPort Integer32, hwIpSpcAttributeLocalIPAddr IpAddress, hwIpSpcAttributeLocalPort Integer32, hwIpSpcAttributeRemoteIPAddr IpAddress, hwIpSpcAttributeRemotePort Integer32, hwIpSpcAttributeVoiceCode INTEGER, hwIpSpcAttributeEce INTEGER, hwIpSpcAttributeSce INTEGER, hwIpSpcAttributeRtpInterval INTEGER, hwIpSpcAttributePlc INTEGER, hwIpSpcAttributeRfc2198 INTEGER, hwIpSpcAttributeJbMode INTEGER, hwIpSpcAttributeWorkMode INTEGER, hwIpSpcAttributeStreamMode INTEGER, hwRemotePortStepNum Integer32, hwLinksetNo Integer32, hwInterfaceID Integer32, hwConfGroup Integer32, hwB1DspInfo OCTET STRING, hwB2DspInfo OCTET STRING, hwSignalType Integer32, hwSpcInitialRingType Integer32, hwSpcCadenceRingType Integer32, hwSpc2833Payload Integer32 } hwSpcNo OBJECT-TYPE SYNTAX Integer32(0..2099) MAX-ACCESS not-accessible STATUS current DESCRIPTION " Index of the SPC Range: 0-2047 for MD products and 0-511 for MA products " ::= { hwSpcMngtEntry 1 } hwStartFrameID OBJECT-TYPE SYNTAX Integer32 (0..97) MAX-ACCESS read-create STATUS current DESCRIPTION " Frame ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSpcMngtEntry 2 } hwStartSlotID OBJECT-TYPE SYNTAX Integer32 (0..35) MAX-ACCESS read-create STATUS current DESCRIPTION " Slot ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSpcMngtEntry 3 } hwStartPort OBJECT-TYPE SYNTAX Integer32 (0..63) MAX-ACCESS read-create STATUS current DESCRIPTION " Port ID of SPC's start point. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSpcMngtEntry 4 } hwStartBsn OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-create STATUS current DESCRIPTION " Channel index of SPC's start point " ::= { hwSpcMngtEntry 5 } hwEndFrameID OBJECT-TYPE SYNTAX Integer32 (0..97|255) MAX-ACCESS read-create STATUS current DESCRIPTION " Shelf ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB. The value 255 indicates that this parameter is not used. " ::= { hwSpcMngtEntry 6 } hwEndSlotID OBJECT-TYPE SYNTAX Integer32 (0..35|255) MAX-ACCESS read-create STATUS current DESCRIPTION " Slot ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB. The value 255 indicates that this parameter is not used. " ::= { hwSpcMngtEntry 7 } hwEndPort OBJECT-TYPE SYNTAX Integer32 (0..63|255) MAX-ACCESS read-create STATUS current DESCRIPTION " Port ID of ANSPC's end point. It must have been described in HUAWEI-DIVICE-MIB. The value 255 indicates that this parameter is not used. " ::= { hwSpcMngtEntry 8 } hwEndBsn OBJECT-TYPE SYNTAX Integer32 (0..31|255) MAX-ACCESS read-create STATUS current DESCRIPTION " Channel index of SPC's end point. The value 255 indicates that this parameter is not used. " ::= { hwSpcMngtEntry 9 } hwChannelNum OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS read-create STATUS current DESCRIPTION " Total channels occupied by the SPC. " ::= { hwSpcMngtEntry 10 } hwApptype OBJECT-TYPE SYNTAX INTEGER { normal(1), -- normal SPC hotline(2), -- hotline SPC mChannelTransparent(3), -- M-Channel Transparent SPC pBX-extention(4), -- PBX extent SPC pBX-bothway(5), -- Bothway SPC e1-DDI(6), -- E1-DDI SPC t1-DDI(7), -- T1-DDI SPC eM-signal(8) -- EM-Signal SPC } MAX-ACCESS read-create STATUS current DESCRIPTION " Applied type of SPC. Options: 1. normal(1) -normal application 2. hotline(2) -hotline application 3. mChannelTransparent(3) -M channel transparent 4. pBX-extention(4) -Z interface extension 5. pBX-bothway(5) -PBX bothway application 6. e1-DDI(6) -E1 direct dial in 7. t1-DDI(7) -T1 direct dial in 8. eM-signal(8) -EM signal application " ::= { hwSpcMngtEntry 11 } hwSpctype OBJECT-TYPE SYNTAX INTEGER { anSpc(1), -- Inner SPC v5Spc(2), -- V5 SPC v5Preconnect(3), -- V5 pre-connection SPC private(4), -- Leased line SPC ipspc(5), -- IP SPC confspc(6) -- conference SPC } MAX-ACCESS read-create STATUS current DESCRIPTION "Configuration type of SPC. Options: 1. anSpc(1) -Internal SPC 2. v5Spc(2) -V5 SPC 3. v5Preconnect(3) -V5 pre-connection SPC 4. private(4) -leased line SPC 5. ipspc(5) -IP SPC 6. confspc(6) -conference SPC " ::= { hwSpcMngtEntry 12 } hwStartPortSubType OBJECT-TYPE SYNTAX INTEGER { noSubType(255), mnt(1), mlt(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Sub type of SPC's start port. If the SPC is used for PHS, the type must be set to mnt or mlt. Options: 1. noSubType(255) -no sub type 2. mnt(1) -mnt 3. mlt(2) -mlt " ::= { hwSpcMngtEntry 13 } hwEndPortSubType OBJECT-TYPE SYNTAX INTEGER { noSubType(255), mnt(1), mlt(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Sub type of SPC's end port. This node is not used on the OLT. Options: 1. noSubType(255) -no sub type 2. mnt(1) -mnt 3. mlt(2) -mlt " ::= { hwSpcMngtEntry 14 } hwPathProtect OBJECT-TYPE SYNTAX INTEGER { yes(1), no(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Enable path protection. This leaf is not used on the OLT. Options: 1. yes(1) -YES 2. no(2) -NO " ::= { hwSpcMngtEntry 15 } hwSPCName OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..31)) MAX-ACCESS read-write STATUS current DESCRIPTION " Name of SPC. It contains 31 characters. - means it is not configured. " ::= { hwSpcMngtEntry 16 } hwSpcState OBJECT-TYPE SYNTAX INTEGER { idle(1), normal(2), error(3), errorChecking(4), occupying(5), checking(6), released(7), errReleasing(8), refreshReleasing(9), disconnecting(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "SPC state. Options: 1. idle(1) -idle 2. normal(2) -normal 3. error(3) -error 4. errorChecking(4) -error checking 5. occupying(5) -occupying 6. checking(6) -checking 7. released(7) -released 8. errReleasing(8) -error releasing 9. refreshReleasing(9) -refresh releasing 10. disconnecting(10) -disconnecting " ::= { hwSpcMngtEntry 17 } hwFailCause OBJECT-TYPE SYNTAX INTEGER { startBusy(1), endBusy(2), startFault(3), endFault(4), startLoop(5), endLoop(6), startLock(7), endLock(8), resNotEnough(9), waitingTimeout(10), startTest(11), endTest(12), noAlarm(13), noTS(14), noLicense(15), linksetFault(16), portUnactive(17) } MAX-ACCESS read-only STATUS current DESCRIPTION "Fault reason of SPC. Options: 1. startBusy(1) -the start port is busy 2. endBusy(2) - the end port is busy 3. startFault(3) - the start port is fault 4. endFault(4) - the end port is fault 5. startLoop(5) - the start port is looped 6. endLoop(6) - the end port is looped 7. startLock(7) - the start port is locked 8. endLock(8) - the end port is locked 9. resNotEnough(9) -the system resource is not enough 10. waitingTimeout(10) -the waiting timer times out 11. startTest(11) -the start port is testing 12. endTest(12) -the end port is testing 13. noAlarm(13) -no alarm 14. noTS(14) -no TS 15. noLicense(15) -no license 16. linksetFault(16) -link set fault 17. portUnactive(17) -port unactive " ::= { hwSpcMngtEntry 18 } hwOprType OBJECT-TYPE SYNTAX INTEGER { noOperation(1), -- No operation connect(2), -- Connect disconnect(3) -- Disconnect } MAX-ACCESS read-write STATUS current DESCRIPTION "Operate type of SPC. It can be set to disconnect or connect. Options: 1. noOperation(1) -no operation 2. connect(2) -connect 3. disconnect(3) -disconnect " ::= { hwSpcMngtEntry 19 } hwRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION " Row status. It supports only CreateAndGo(4) and Destroy(6). " ::= { hwSpcMngtEntry 20 } hwStartCESFrame OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Start CES shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 21 } hwStartCESSlot OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "CES slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 22 } hwStartCESPort OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Start CES port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 23 } hwStartUpPv8Frame OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Start upstream PV8 shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 24 } hwStartUpPv8Slot OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Start upstream PV8 slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 25 } hwStartUpPv8Port OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Start upstream PV8 port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 26 } hwStartDownPv8Frame OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Start downstream PV8 shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 27 } hwStartDownPv8Slot OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Start downstream PV8 slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 28 } hwStartDownPv8Port OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Start downstream PV8 port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 29 } hwStartRspFrame OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Start downstream RSP shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 30 } hwStartRspSlot OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Start downstream RSP slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 31 } hwStartRspPort OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Start downstream RSP port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 32 } hwEndtCESFrame OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End downstream CES shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 33 } hwEndCESSlot OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End downstream CES slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 34 } hwEndCESPort OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End CES port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 35 } hwEndUpPv8Frame OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End upstream PV8 shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 36 } hwEndUpPv8Slot OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End upstream PV8 slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 37 } hwEndUpPv8Port OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End upstream PV8 port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 38 } hwEndDownPv8Frame OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End downstream PV8 shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 39 } hwEndDownPv8Slot OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End downstream PV8 slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 40 } hwEndDownPv8Port OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End downstream PV8 port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 41 } hwEndRspFrame OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End RSP shelf. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 42 } hwEndRspSlot OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End RSP slot. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 43 } hwEndRspPort OBJECT-TYPE SYNTAX Integer32 (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "End RSP port. If the value is 255, it indicates that the SPC does not use this path. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 44 } hwIpSpcAttributeLocalIPAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Local IP address of the SPC. If the SPC's type is IPSPC, the local IP address must be configured. " ::= { hwSpcMngtEntry 45 } hwIpSpcAttributeLocalPort OBJECT-TYPE SYNTAX Integer32(0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Local UDP port of the SPC. If the SPC's type is IPSPC, the local UDP port must be configured. " ::= { hwSpcMngtEntry 46 } hwIpSpcAttributeRemoteIPAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Remote IP address of the SPC. If the SPC's type is IPSPC, the remote IP address mustd be configured. " ::= { hwSpcMngtEntry 47 } hwIpSpcAttributeRemotePort OBJECT-TYPE SYNTAX Integer32(0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Remote UDP port of the SPC. If the SPC's type is IPSPC, the remote UDP port must be configured. " ::= { hwSpcMngtEntry 48 } hwIpSpcAttributeVoiceCode OBJECT-TYPE SYNTAX INTEGER { acG711Malaw(1), -- G.711A acG711Mulaw(2), -- G.711U acG723Low(3), -- G.723low acG723High(4), -- G.723high acG729(5), -- G.729 clearMode(6), -- clear mode g72616k(7), -- G.726_16K g72624k(8), -- G.726_24K g72632k(9), -- G.726_32K g72640k(10), -- G.726_40K g722(11), -- G.722 invalid(-1) -- invalid value } MAX-ACCESS read-write STATUS current DESCRIPTION "Voice codec type of the SPC. Options: 1. acG711Malaw(1) -G.711A 2. acG711Mulaw(2) -G.711U 3. acG723Low(3) -G.723low 4. acG723High(4) -G.723high 5. acG729(5) -G.729 6. clearMode(6) -clear mode 7. g72616k(7) -G.726_16K 8. g72624k(8) -G.726_24K 9. g72632k(9) -G.726_32K 10. g72640k(10) -G.726_40K 11. g722(11) -G.722 12. invalid(-1) -invalid value " ::= { hwSpcMngtEntry 49 } hwIpSpcAttributeEce OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION " The switch of EC. Options: 1. disable(1) -disable EC 2. enable(2) -enable EC 3. invalid(-1) -invalid value " ::= { hwSpcMngtEntry 50 } hwIpSpcAttributeSce OBJECT-TYPE SYNTAX INTEGER { disable(1), enable(2), invalid(-1) } MAX-ACCESS read-write STATUS current DESCRIPTION " The switch of SC. Options: 1. disable(1) -disable SC 2. enable(2) -enable SC 3. invalid(-1) -invalid value " ::= { hwSpcMngtEntry 51 } hwIpSpcAttributeRtpInterval OBJECT-TYPE SYNTAX INTEGER { five(1), ten(2), twenty(3), thirty(4), invalid(255) } MAX-ACCESS read-write STATUS current DESCRIPTION "RTP sampling time. Options: 1. five(1) -5 ms 2. ten(2) -10 ms 3. twenty(3) -20 ms 4. thirty(4) -30 ms 5. invalid(255) -invalid value Unit: millisecond " ::= { hwSpcMngtEntry 52} hwIpSpcAttributePlc OBJECT-TYPE SYNTAX INTEGER{ enable(1),disable(2),invalid(255)} MAX-ACCESS read-write STATUS current DESCRIPTION "The switch of PLC. Options: 1. enable(1) -enable PLC 2. disable(2) -disable PLC 3. invalid(255) -invalid value " ::= { hwSpcMngtEntry 53} hwIpSpcAttributeRfc2198 OBJECT-TYPE SYNTAX INTEGER{ enable(1),disable(2),invalid(255)} MAX-ACCESS read-write STATUS current DESCRIPTION " The switch of 2198. Options: 1. enable(1) -enable RFC2198 redundancy 2. disable(2) -disable RFC2198 redundancy 3. invalid(255) -invalid value " ::= { hwSpcMngtEntry 54} hwIpSpcAttributeJbMode OBJECT-TYPE SYNTAX INTEGER{ adapt(1),fixed(2),invalid(255)} MAX-ACCESS read-write STATUS current DESCRIPTION "Jitterbuffer mode. Options: 1. adapt(1) -adapt 2. fixed(2) -fixed 3. invalid(255) -invalid value " ::= { hwSpcMngtEntry 55} hwIpSpcAttributeWorkMode OBJECT-TYPE SYNTAX INTEGER{ voice(1),fax(2),modem(3),invalid(255) } MAX-ACCESS read-write STATUS current DESCRIPTION " DSP work mode. Options: 1. voice(1) -voice 2. fax(2) -fax 3. modem(3) -modem 4. invalid(255) -invalid value " ::= { hwSpcMngtEntry 56} hwIpSpcAttributeStreamMode OBJECT-TYPE SYNTAX INTEGER{ sendReceive(1),sendOnly(2),receiveOnly(3),invalid(255) } MAX-ACCESS read-write STATUS current DESCRIPTION " Connect mode. Options: 1. sendReceive(1) -send and receive 2. sendOnly(2) -send only 3. receiveOnly(3) -receive only 4. invalid(255) -invalid value " ::= { hwSpcMngtEntry 57} hwRemotePortStepNum OBJECT-TYPE SYNTAX Integer32 (1..65534|65535) MAX-ACCESS read-create STATUS current DESCRIPTION " The remote-port step. If the value is 65535, the ANSPC does not use the remote port step number attribute. " ::= { hwSpcMngtEntry 58 } hwLinksetNo OBJECT-TYPE SYNTAX Integer32 (0..31|-1) MAX-ACCESS read-create STATUS current DESCRIPTION " IUA link set number. In the case of the U interface transparent, this parameter must be configured. If the value is -1, it indicates that the SPC does not use the IUA link set number. " ::= { hwSpcMngtEntry 59 } hwInterfaceID OBJECT-TYPE SYNTAX Integer32 (0..65535|-1) MAX-ACCESS read-create STATUS current DESCRIPTION " IUA interface ID. In the case of the U interface transparent, this parameter must be configured. If the value is -1, it indicates that the SPC does not use the IUA interface ID. " ::= { hwSpcMngtEntry 60 } hwConfGroup OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-create STATUS current DESCRIPTION " Conference Group ID. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 61 } hwB1DspInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (9..32)) MAX-ACCESS read-only STATUS current DESCRIPTION " Information of B1 DSP in conference service or BRA IP service. It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID. This leaf is not used on the OLT. " ::= { hwSpcMngtEntry 62 } hwB2DspInfo OBJECT-TYPE SYNTAX OCTET STRING (SIZE (9..32)) MAX-ACCESS read-only STATUS current DESCRIPTION " Information of B2 DSP in BRA ip service. It contains 32 characters and it is in the format of FrameID/SlotID/CardID/ChipID/CHNID This leaf is not used on OLT. " ::= { hwSpcMngtEntry 63 } hwSignalType OBJECT-TYPE SYNTAX Integer32 (1..2) MAX-ACCESS read-write STATUS current DESCRIPTION " Signal type of IP SPC. Options: 1. 1 - normal 2. 2 - 2833 This leaf is only used on the UA5000. " ::= { hwSpcMngtEntry 64} hwSpcInitialRingType OBJECT-TYPE SYNTAX Integer32 (1..27) MAX-ACCESS read-write STATUS current DESCRIPTION "IP SPC initial ring type. Enumeration type: 1-Null, 2-Normal ring (FSK) 1:4, 3-Special ring (FSK) 1:2, 4-Special ring (FSK) 0.4:0.2:0.4:4, 5-Special ring (FSK) 1.2:2, 6-HK ring (FSK) 1:3, 7-HK CNTRX (FSK) 0.4:0.2:0.4:0.2:0.4:3.0, 8-HK DN-A (FSK) 0.4:0.2:0.4:3.0, 9-HK DN-B (FSK) 1.2:3, 10-CNTRX-IN (FSK) 0.4:0.2:0.4:0.2:0.4:2.6, 11-Egypt long-distance ring (FSK) 2:1, 12-user defined FSK ring mode 0, 13-user defined FSK ring mode 1, 14-user defined FSK ring mode 2, 15-user defined FSK ring mode 3, 16-user defined FSK ring mode 4, 17-user defined FSK ring mode 5, 18-user defined FSK ring mode 6, 19-user defined FSK ring mode 7, 20-user defined FSK ring mode 8, 21-user defined FSK ring mode 9, 22-user defined FSK ring mode 10, 23-user defined FSK ring mode 11, 24-user defined FSK ring mode 12, 25-user defined FSK ring mode 13, 26-user defined FSK ring mode 14, 27-user defined FSK ring mode 15 This leaf is only used on the UA5000. " ::= { hwSpcMngtEntry 65 } hwSpcCadenceRingType OBJECT-TYPE SYNTAX Integer32 (1..30) MAX-ACCESS read-write STATUS current DESCRIPTION "IP SPC cadence ring type. Enumerated types: 1-Null, 2-Normal ring 1:4, 3-Special ring 1:2, 4-Special ring 0.4:0.2:0.4:4, 5-Long ring, 6-Special ring 1.2:2, 7-HK ring 1:3, 8-HK CNTRX 0.4:0.2:0.4:0.2:0.4:3.0, 9-HK DN-A 0.4:0.2:0.4:3.0, 10-HK ACB 0.4:0.2, 11-HK reminder ring (one tone every 0.4 second; one tone), 12-HK DN-B 1.2:3, 13-CNTRX-IN 0.4:0.2:0.4:0.2:0.4:2.6, 14-Egypt long-distance ring 2:1, 15-user defined ring mode 0, 16-user defined ring mode 1, 17-user defined ring mode 2, 18-user defined ring mode 3, 19-user defined ring mode 4, 20-user defined ring mode 5, 21-user defined ring mode 6, 22-user defined ring mode 7, 23-user defined ring mode 8, 24-user defined ring mode 9, 25-user defined ring mode 10, 26-user defined ring mode 11, 27-user defined ring mode 12, 28-user defined ring mode 13, 29-user defined ring mode 14, 30-user defined ring mode 15 This leaf is only used on the UA5000. " ::= { hwSpcMngtEntry 66 } hwSpc2833Payload OBJECT-TYPE SYNTAX Integer32 (96..127) MAX-ACCESS read-write STATUS current DESCRIPTION "IP SPC 2833 payload type. This leaf is only used on the UA5000. " ::= { hwSpcMngtEntry 67 } hwNextAllocSpcNo OBJECT-TYPE SYNTAX Integer32(0..2099) MAX-ACCESS read-only STATUS current DESCRIPTION " Next valid allocation of SPC index Range: 0-2047 for MD products and 0-511 for MA products. " ::= { hwSpcMibObjects 3 } hwSpcProtectGroupTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSpcProtectGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "You can add, delete, modify or query SPC protect group using hwSpcProtectGroupTable. The index of this table is hwSpcProtectGroupID. " ::= { hwSpcMibObjects 4 } hwSpcProtectGroupEntry OBJECT-TYPE SYNTAX HwSpcProtectGroupEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "You can add, delete, modify or query SPC protect group using hwSpcProtectGroupTable. The index of this entry is hwSpcProtectGroupID. " INDEX { hwSpcProtectGroupID } ::= { hwSpcProtectGroupTable 1 } HwSpcProtectGroupEntry ::= SEQUENCE { hwSpcProtectGroupID Integer32, hwSpcMainPortFrameID Integer32, hwSpcMainPortSlotID Integer32, hwSpcMainPortPortID Integer32, hwProtectGroupRowStatus RowStatus } hwSpcProtectGroupID OBJECT-TYPE SYNTAX Integer32(0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION " Index of the SPC E1 protect group. Range: 0-2 for UA products. " ::= { hwSpcProtectGroupEntry 1 } hwSpcMainPortFrameID OBJECT-TYPE SYNTAX Integer32 (0..97) MAX-ACCESS read-write STATUS current DESCRIPTION " Frame ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSpcProtectGroupEntry 2 } hwSpcMainPortSlotID OBJECT-TYPE SYNTAX Integer32 (0..35) MAX-ACCESS read-write STATUS current DESCRIPTION " Slot ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSpcProtectGroupEntry 3 } hwSpcMainPortPortID OBJECT-TYPE SYNTAX Integer32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION " Port ID of SPC E1 protect service link. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSpcProtectGroupEntry 4 } hwProtectGroupRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION " Row status. It supports only CreateAndGo(4) and Destroy(6). " ::= { hwSpcProtectGroupEntry 5 } hwSpcProtectTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSpcProtectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "You can add, delete, modify or query SPC protect link using hwSpcProtectTable. The index of this table is hwSpcProtectID. " ::= { hwSpcMibObjects 5 } hwSpcProtectEntry OBJECT-TYPE SYNTAX HwSpcProtectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "You can add, delete, modify or query SPC protect link using hwSpcProtectTable. The index of this entry is hwSpcProtectID. " INDEX { hwSpcProtectID } ::= { hwSpcProtectTable 1 } HwSpcProtectEntry ::= SEQUENCE { hwSpcProtectID Integer32, hwSpcProtectGroupId Integer32, hwSpcProtectPortFrameID Integer32, hwSpcProtectPortSlotID Integer32, hwSpcProtectPortPortID Integer32, hwSpcProtectPriority Integer32, hwSpcProtectUsedFlag Integer32, hwProtectLinkRowStatus RowStatus } hwSpcProtectID OBJECT-TYPE SYNTAX Integer32(0..8) MAX-ACCESS not-accessible STATUS current DESCRIPTION " Index of the SPC E1 protect link. Range: 0-8 for UA products. " ::= { hwSpcProtectEntry 1 } hwSpcProtectGroupId OBJECT-TYPE SYNTAX Integer32(0..2) MAX-ACCESS not-accessible STATUS current DESCRIPTION " Index of the SPC E1 protect group. " ::= { hwSpcProtectEntry 2 } hwSpcProtectPortFrameID OBJECT-TYPE SYNTAX Integer32 (0..97) MAX-ACCESS read-write STATUS current DESCRIPTION " Frame ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSpcProtectEntry 3 } hwSpcProtectPortSlotID OBJECT-TYPE SYNTAX Integer32 (0..35) MAX-ACCESS read-write STATUS current DESCRIPTION " Slot ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSpcProtectEntry 4 } hwSpcProtectPortPortID OBJECT-TYPE SYNTAX Integer32 (0..63) MAX-ACCESS read-write STATUS current DESCRIPTION " Port ID of SPC E1 protect link. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSpcProtectEntry 5 } hwSpcProtectPriority OBJECT-TYPE SYNTAX Integer32 (1..3) MAX-ACCESS read-write STATUS current DESCRIPTION " Priority of SPC E1 protect link. 1: cat1(1), 2: cat1(2), 3: cat1(3). " ::= { hwSpcProtectEntry 6 } hwSpcProtectUsedFlag OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION " State of the SPC E1 protect link. " ::= { hwSpcProtectEntry 7 } hwProtectLinkRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION " Row status. It supports only CreateAndGo(4) and Destroy(6). " ::= { hwSpcProtectEntry 8 } -- start: add for scs hwSubRateSwitchTable OBJECT-TYPE SYNTAX SEQUENCE OF HwSubRateSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "You can add, delete, modify or query sub-rate switch using hwSubRateSwitchTable. The index of this table is hwSubRateSwitchID. " ::= { hwSpcMibObjects 6 } hwSubRateSwitchEntry OBJECT-TYPE SYNTAX HwSubRateSwitchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "You can add, delete, modify or query sub-rate switch using hwSubRateSwitchTable. The index of this entry is hwSubRateSwitchID. " INDEX { hwSubRateSwitchID } ::= { hwSubRateSwitchTable 1 } HwSubRateSwitchEntry ::= SEQUENCE { hwSubRateSwitchID Integer32, hwSubRateSwitchStartFrameID Integer32, hwSubRateSwitchStartSlotID Integer32, hwSubRateSwitchStartPortID Integer32, hwSubRateSwitchStartChannelID Integer32, hwSubRateSwitchStartSubChannelID Integer32, hwSubRateSwitchEndFrameID Integer32, hwSubRateSwitchEndSlotID Integer32, hwSubRateSwitchEndPortID Integer32, hwSubRateSwitchEndChannelID Integer32, hwSubRateSwitchEndSubChannelID Integer32, hwSubRateSwitchState INTEGER, hwSubRateSwitchRowStatus RowStatus } hwSubRateSwitchID OBJECT-TYPE SYNTAX Integer32(0..1023) MAX-ACCESS not-accessible STATUS current DESCRIPTION " Index of the sub-rate switch " ::= { hwSubRateSwitchEntry 1 } hwSubRateSwitchStartFrameID OBJECT-TYPE SYNTAX Integer32 (0..97) MAX-ACCESS read-create STATUS current DESCRIPTION " Frame ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSubRateSwitchEntry 2 } hwSubRateSwitchStartSlotID OBJECT-TYPE SYNTAX Integer32 (0..35) MAX-ACCESS read-create STATUS current DESCRIPTION " Slot ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSubRateSwitchEntry 3 } hwSubRateSwitchStartPortID OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-create STATUS current DESCRIPTION " Port ID of sub-rate switch start point. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSubRateSwitchEntry 4 } hwSubRateSwitchStartChannelID OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-create STATUS current DESCRIPTION " Channel index of sub-rate switch start point " ::= { hwSubRateSwitchEntry 5 } hwSubRateSwitchStartSubChannelID OBJECT-TYPE SYNTAX Integer32 (0..19) MAX-ACCESS read-create STATUS current DESCRIPTION " sub-rate channel index of sub-rate switch start point " ::= { hwSubRateSwitchEntry 6 } hwSubRateSwitchEndFrameID OBJECT-TYPE SYNTAX Integer32 (0..97) MAX-ACCESS read-create STATUS current DESCRIPTION " Frame ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSubRateSwitchEntry 7 } hwSubRateSwitchEndSlotID OBJECT-TYPE SYNTAX Integer32 (0..35) MAX-ACCESS read-create STATUS current DESCRIPTION " Slot ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSubRateSwitchEntry 8 } hwSubRateSwitchEndPortID OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-create STATUS current DESCRIPTION " Port ID of sub-rate switch end point. It must have been described in HUAWEI-DIVICE-MIB. " ::= { hwSubRateSwitchEntry 9 } hwSubRateSwitchEndChannelID OBJECT-TYPE SYNTAX Integer32 (0..31) MAX-ACCESS read-create STATUS current DESCRIPTION " Channel index of sub-rate switch end point. " ::= { hwSubRateSwitchEntry 10 } hwSubRateSwitchEndSubChannelID OBJECT-TYPE SYNTAX Integer32 (0..19) MAX-ACCESS read-create STATUS current DESCRIPTION " sub-rate channel index of sub-rate switch end point. " ::= { hwSubRateSwitchEntry 11 } hwSubRateSwitchState OBJECT-TYPE SYNTAX INTEGER { fault(1), normal(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "sub-rate switch state. Options: 1. fault(1) -fault 2. normal(2) -normal " ::= { hwSubRateSwitchEntry 12 } hwSubRateSwitchRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION " Row status. It supports only CreateAndGo(4) and Destroy(6). " ::= { hwSubRateSwitchEntry 13 } hwNextAllocSubRateSwitchID OBJECT-TYPE SYNTAX Integer32(0..1023) MAX-ACCESS read-only STATUS current DESCRIPTION " Next valid allocation of SubRateSwitch index Range: 0-1023. " ::= { hwSpcMibObjects 7 } hwIpSpcMinUdp OBJECT-TYPE SYNTAX Integer32(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " Start UDP port of IPSPC. Range: 0-65535. " ::= { hwSpcMibObjects 8 } hwIpSpcMaxUdp OBJECT-TYPE SYNTAX Integer32(0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION " End UDP port of IPSPC. Range: 0-65535. " ::= { hwSpcMibObjects 9 } -- end: add for scs hwSpcMibTrap OBJECT IDENTIFIER ::= { hwSpc 2 } hwSpcTrapOid OBJECT IDENTIFIER ::= { hwSpcMibTrap 1 } hwSpcTrapsDefine OBJECT IDENTIFIER ::= { hwSpcMibTrap 2 } hwSpcTraps OBJECT IDENTIFIER ::= { hwSpcTrapsDefine 0 } hwSpcMibCompance OBJECT IDENTIFIER ::= { hwSpc 3 } hwIASSpcTrapsVbOids OBJECT IDENTIFIER ::= { hwSpc 4 } hwIASSpcTraps OBJECT IDENTIFIER ::= { hwSpc 5 } hwIASSpcCommonTraps OBJECT IDENTIFIER ::= { hwIASSpcTraps 1 } hwIASSpcAlarmTraps OBJECT IDENTIFIER ::= { hwIASSpcTraps 2 } ------ /* Start hwIASSpcTrapsVbOids */ hwIASSpcBChn OBJECT-TYPE SYNTAX Unsigned32(0..32) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " Indicates the B-channel. " ::= { hwIASSpcTrapsVbOids 1 } hwIASSpcDspFrame OBJECT-TYPE SYNTAX Unsigned32(0..255) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " Indicate the shelf ID of a DSP resource board. " ::= { hwIASSpcTrapsVbOids 2 } hwIASSpcDspSlot OBJECT-TYPE SYNTAX Unsigned32(0..255) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " Indicate the slot ID of a DSP resource board. " ::= { hwIASSpcTrapsVbOids 3 } hwIASSpcDspSub OBJECT-TYPE SYNTAX Unsigned32(0..255) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " Indicate the DSP sub-board ID of a resource board. " ::= { hwIASSpcTrapsVbOids 4 } hwIASSpcDspChannel OBJECT-TYPE SYNTAX Unsigned32(0..65535) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " Indicate the DSP inner channel ID of a subboard. " ::= { hwIASSpcTrapsVbOids 5 } hwIASSpcDspLoopdelay OBJECT-TYPE SYNTAX Unsigned32(0..4294967295) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " Indicate the DSP loop delay. " ::= { hwIASSpcTrapsVbOids 6 } hwIASSpcDspFractionLost OBJECT-TYPE SYNTAX Unsigned32(0..4294967295) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " Indicate the DSP fractionLost. " ::= { hwIASSpcTrapsVbOids 7 } hwIASSpcDspJitter OBJECT-TYPE SYNTAX Unsigned32(0..4294967295) MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " The DSP jitter. " ::= { hwIASSpcTrapsVbOids 8 } hwIASSpcOperateType OBJECT-TYPE SYNTAX INTEGER{ add(0), delete(1), modify(2), release(3), undorelease(4), dspconfig(5) } MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION " Indicate the operate type on a SPC. Options: 1. add(0) -add spc link 2. delete(1) -delete spc link 3. modify(2) -modify spc link 4. release(3) -spc link end service 5. undorelease(4) -spc link start service 6. dspconfig(5) -config spc link dsp parameters " ::= { hwIASSpcTrapsVbOids 9 } ------ /* End hwIASSpcTrapsVbOids */ ------ /* Start hwIASSpcCommonTraps */ hwIASSpcOperateTrap NOTIFICATION-TYPE OBJECTS { hwSpcNo,hwIASSpcOperateType } STATUS current DESCRIPTION " This notification indicates that the operation on the SPC. " ::= { hwIASSpcCommonTraps 0 1 } ------ /* End hwIASSpcCommonTraps */ ------ /* Start hwIASSpcAlarmTraps */ hwIASSpcFaultTrap NOTIFICATION-TYPE OBJECTS { hwSpcNo } STATUS current DESCRIPTION " This notification indicates that the SPC is faulty. " ::= { hwIASSpcAlarmTraps 0 1 } hwIASSpcRestoreTrap NOTIFICATION-TYPE OBJECTS { hwSpcNo } STATUS current DESCRIPTION " This notification indicates that the SPC recovers from a fault. " ::= { hwIASSpcAlarmTraps 0 2 } hwIASSpcReleaseTrap NOTIFICATION-TYPE OBJECTS { hwSpcNo } STATUS current DESCRIPTION " This notification indicates that the SPC is released. " ::= { hwIASSpcAlarmTraps 0 3 } hwIASSpcConnectTrap NOTIFICATION-TYPE OBJECTS { hwSpcNo } STATUS current DESCRIPTION " This notification indicates that the SPC is connected again. " ::= { hwIASSpcAlarmTraps 0 4 } hwIASSpcQosExceedTrap NOTIFICATION-TYPE OBJECTS { hwSpcNo, hwIASSpcBChn, hwIASSpcDspFrame, hwIASSpcDspSlot, hwIASSpcDspSub, hwIASSpcDspChannel, hwIpSpcAttributeRemoteIPAddr, hwIASSpcDspLoopdelay, hwIASSpcDspFractionLost, hwIASSpcDspJitter } STATUS current DESCRIPTION " This notification indicates that the value of DSP QoS used by the SPC exceeds the threshold. " ::= { hwIASSpcAlarmTraps 0 5 } hwIASSpcQosRestoreTrap NOTIFICATION-TYPE OBJECTS { hwSpcNo, hwIASSpcBChn, hwIASSpcDspFrame, hwIASSpcDspSlot, hwIASSpcDspSub, hwIASSpcDspChannel, hwIpSpcAttributeRemoteIPAddr, hwIASSpcDspLoopdelay, hwIASSpcDspFractionLost, hwIASSpcDspJitter } STATUS current DESCRIPTION " This notification indicates that the value of DSP QoS used by the SPC is normal. " ::= { hwIASSpcAlarmTraps 0 6 } ------ /* End hwIASSpcAlarmTraps */ END