-- Copyright (c) 2010-2013 Hewlett-Packard Development Company, L.P.
--
-- Description:This MIB file is used for management of userlog
-- information.
-- Reference:
-- Version: V1.1
-- History:
-- V1.0
-- 31st Mar 2003
-- tianli, initial version
-- V1.1 2005-07-05
-- Modify value range of hpnicfUserlogNatAclNumber and hpnicfUserlogFlowAclNumber
-- by tanbo02122.
-- Update file format by gaolong.
-- =================================================================
HPN-ICF-USERLOG-MIB DEFINITIONS ::= BEGIN
IMPORTS
hpnicfRhw
FROM HPN-ICF-OID-MIB
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
IpAddress, Integer32, Counter32, OBJECT-TYPE,
MODULE-IDENTITY
FROM SNMPv2-SMI;
hpnicfUserLogMIB MODULE-IDENTITY
LAST-UPDATED "200304100000Z" -- April 10, 2003 at 00:00 GMT
ORGANIZATION
""
CONTACT-INFO
""
DESCRIPTION
"The HPN-ICF-USERLOG-MIB contains objects to
Manage configuration and Monitor running state
for userlog feature."
::= { hpnicfRhw 18 }
hpnicfUserlogObjects OBJECT IDENTIFIER ::= { hpnicfUserLogMIB 1 }
hpnicfUserlogNatObjects OBJECT IDENTIFIER ::= { hpnicfUserlogObjects 1 }
hpnicfUserlogNatVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"NAT LOG version. Currently only version 1 is developed."
::= { hpnicfUserlogNatObjects 1 }
hpnicfUserlogNatSyslog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
NAT LOG format.
If 1, LOG format is sysLog.
If 0, LOG format is UDP packet.
UDP packet is the default format, and is recommended.
"
::= { hpnicfUserlogNatObjects 2 }
hpnicfUserlogNatSourceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Source IP address of NAT LOG UDP packet."
::= { hpnicfUserlogNatObjects 3 }
hpnicfUserlogNatFlowBegin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Log the NAT flow when it is created.
If 1, this function is enabled.
If 0, this function is disabled.
This function will be used when real-time monitor required.
"
::= { hpnicfUserlogNatObjects 4 }
hpnicfUserlogNatActiveTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
The active time for long-time existed NAT flow.
Unit: minute. Range: 10 minutes ~ 120 minutes.
When setting it, NAT flow can be logged after an interval of
active time.
This function will be used when real-time monitor required.
The default value 0 means real-time monitor function is disabled.
"
::= { hpnicfUserlogNatObjects 5 }
hpnicfUserlogNatSlotCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpnicfUserlogNatSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of NAT LOG configuration information for the
specified slot."
::= { hpnicfUserlogNatObjects 6 }
hpnicfUserlogNatSlotCfgInfoEntry OBJECT-TYPE
SYNTAX HpnicfUserlogNatSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"NAT LOG Configuration Information Entry for a slot."
INDEX { hpnicfUserlogNatCfgSlotNumber }
::= { hpnicfUserlogNatSlotCfgInfoTable 1 }
HpnicfUserlogNatSlotCfgInfoEntry ::=
SEQUENCE {
hpnicfUserlogNatCfgSlotNumber
Integer32,
hpnicfUserlogNatEnable
Integer32,
hpnicfUserlogNatAclNumber
Integer32,
hpnicfUserlogNatHostAddress
IpAddress,
hpnicfUserlogNatUdpPort
Integer32
}
hpnicfUserlogNatCfgSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify which slot is configured with NAT LOG. "
::= { hpnicfUserlogNatSlotCfgInfoEntry 1 }
hpnicfUserlogNatEnable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
The NAT LOG feature Enable status.
If 1, NAT LOG is enbled.
If 0, NAT LOG is disabled.
"
::= { hpnicfUserlogNatSlotCfgInfoEntry 2 }
hpnicfUserlogNatAclNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Access-list number.
The value 0 means no ACL is specified.
Only when NAT LOG is enabled, can ACL be configured.
Only NAT flow which match the ACL will be logged.
"
::= { hpnicfUserlogNatSlotCfgInfoEntry 3 }
hpnicfUserlogNatHostAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of NAT LOG server. "
::= { hpnicfUserlogNatSlotCfgInfoEntry 4 }
hpnicfUserlogNatUdpPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP Port Number of NAT LOG UDP packet."
::= { hpnicfUserlogNatSlotCfgInfoEntry 5 }
hpnicfUserlogNatSlotRunInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpnicfUserlogNatSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of NAT LOG running information for the specified slot."
::= { hpnicfUserlogNatObjects 7 }
hpnicfUserlogNatSlotRunInfoEntry OBJECT-TYPE
SYNTAX HpnicfUserlogNatSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"NAT LOG Running Information Entry for a slot."
INDEX { hpnicfUserlogNatRunSlotNumber }
::= { hpnicfUserlogNatSlotRunInfoTable 1 }
HpnicfUserlogNatSlotRunInfoEntry ::=
SEQUENCE {
hpnicfUserlogNatRunSlotNumber
Integer32,
hpnicfUserlogNatTotalEntries
Counter32,
hpnicfUserlogNatTotalPackets
Counter32,
hpnicfUserlogNatFailedEntries
Counter32,
hpnicfUserlogNatFailedPackets
Counter32,
hpnicfUserlogNatClearRunStat
Integer32
}
hpnicfUserlogNatRunSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify on which slot the NAT LOG statistics
displayed."
::= { hpnicfUserlogNatSlotRunInfoEntry 1 }
hpnicfUserlogNatTotalEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT flow entries which are logged."
::= { hpnicfUserlogNatSlotRunInfoEntry 2 }
hpnicfUserlogNatTotalPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT LOG UDP packets generated by the router."
::= { hpnicfUserlogNatSlotRunInfoEntry 3 }
hpnicfUserlogNatFailedEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT flow entries failed in outputting."
::= { hpnicfUserlogNatSlotRunInfoEntry 4 }
hpnicfUserlogNatFailedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of NAT LOG UDP packets failed in outputting."
::= { hpnicfUserlogNatSlotRunInfoEntry 5 }
hpnicfUserlogNatClearRunStat OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear the running statistics for NAT LOG. Write-only.
If 1, the running statistics for NAT LOG is resetted.
Other value is invalid.
"
::= { hpnicfUserlogNatSlotRunInfoEntry 6 }
hpnicfUserlogFlowObjects OBJECT IDENTIFIER ::= { hpnicfUserlogObjects 2 }
hpnicfUserlogFlowVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BAS FLOW LOG version. Currently only version 1 is developed."
::= { hpnicfUserlogFlowObjects 1 }
hpnicfUserlogFlowSyslog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
BAS FLOW LOG format.
If 1, LOG format is sysLog.
If 0, LOG format is UDP packet.
UDP packet is the default format, and is recommended.
"
::= { hpnicfUserlogFlowObjects 2 }
hpnicfUserlogFlowSourceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Source IP address of BAS FLOW LOG UDP packet."
::= { hpnicfUserlogFlowObjects 3 }
hpnicfUserlogFlowFlowBegin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Log the BAS flow when it is created.
If 1, this function is enabled.
If 0, this function is disabled.
This function will be used when real-time monitor required.
"
::= { hpnicfUserlogFlowObjects 4 }
hpnicfUserlogFlowActiveTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
The active time for long-time existed BAS flow.
Unit: minute. Range: 10 minutes ~ 120 minutes.
When setting it, BAS flow can be logged after an internal of
active time.
This function will be used when real-time monitor required.
The default value 0 means real-time monitor function is disabled.
"
::= { hpnicfUserlogFlowObjects 5 }
hpnicfUserlogFlowSlotCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpnicfUserlogFlowSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS FLOW LOG configuration information for the
specified slot."
::= { hpnicfUserlogFlowObjects 6 }
hpnicfUserlogFlowSlotCfgInfoEntry OBJECT-TYPE
SYNTAX HpnicfUserlogFlowSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BAS FLOW LOG Configuration Information Entry for a slot."
INDEX { hpnicfUserlogFlowCfgSlotNumber }
::= { hpnicfUserlogFlowSlotCfgInfoTable 1 }
HpnicfUserlogFlowSlotCfgInfoEntry ::=
SEQUENCE {
hpnicfUserlogFlowCfgSlotNumber
Integer32,
hpnicfUserlogFlowEnable
Integer32,
hpnicfUserlogFlowAclNumber
Integer32,
hpnicfUserlogFlowHostAddress
IpAddress,
hpnicfUserlogFlowUdpPort
Integer32
}
hpnicfUserlogFlowCfgSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify which slot is configured with BAS FLOW LOG."
::= { hpnicfUserlogFlowSlotCfgInfoEntry 1 }
hpnicfUserlogFlowEnable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
The BAS FLOW LOG feature Enable status.
If 1, BAS FLOW LOG is enbled.
If 0, BAS FLOW LOG is disabled.
"
::= { hpnicfUserlogFlowSlotCfgInfoEntry 2 }
hpnicfUserlogFlowAclNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Access-list number.
The value 0 means no ACL is specified.
Only when BAS FLOW LOG is enabled, can ACL be configured.
Only BAS flow which match the ACL will be logged.
"
::= { hpnicfUserlogFlowSlotCfgInfoEntry 3 }
hpnicfUserlogFlowHostAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of BAS FLOW LOG server. "
::= { hpnicfUserlogFlowSlotCfgInfoEntry 4 }
hpnicfUserlogFlowUdpPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP Port Number of BAS FLOW LOG UDP packet."
::= { hpnicfUserlogFlowSlotCfgInfoEntry 5 }
hpnicfUserlogFlowSlotRunInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpnicfUserlogFlowSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS FLOW LOG running information for the specified slot."
::= { hpnicfUserlogFlowObjects 7 }
hpnicfUserlogFlowSlotRunInfoEntry OBJECT-TYPE
SYNTAX HpnicfUserlogFlowSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Running Information Entry for a slot."
INDEX { hpnicfUserlogFlowRunSlotNumber }
::= { hpnicfUserlogFlowSlotRunInfoTable 1 }
HpnicfUserlogFlowSlotRunInfoEntry ::=
SEQUENCE {
hpnicfUserlogFlowRunSlotNumber
Integer32,
hpnicfUserlogFlowTotalEntries
Counter32,
hpnicfUserlogFlowTotalPackets
Counter32,
hpnicfUserlogFlowFailedEntries
Counter32,
hpnicfUserlogFlowFailedPackets
Counter32,
hpnicfUserlogFlowClearRunStat
Integer32
}
hpnicfUserlogFlowRunSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify on which slot the BAS FLOW LOG
statistics displayed."
::= { hpnicfUserlogFlowSlotRunInfoEntry 1 }
hpnicfUserlogFlowTotalEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS FLOW Entries which are logged."
::= { hpnicfUserlogFlowSlotRunInfoEntry 2 }
hpnicfUserlogFlowTotalPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of FLOW LOG UDP packet generated by the router."
::= { hpnicfUserlogFlowSlotRunInfoEntry 3 }
hpnicfUserlogFlowFailedEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS FLOW entries failed in outputting. "
::= { hpnicfUserlogFlowSlotRunInfoEntry 4 }
hpnicfUserlogFlowFailedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS FLOW LOG UDP packet failed in outputting."
::= { hpnicfUserlogFlowSlotRunInfoEntry 5 }
hpnicfUserlogFlowClearRunStat OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear the running statistics for FLOW LOG. Write-only.
If 1, the running statistics for FLOW LOG is resetted.
Other value is invalid.
"
::= { hpnicfUserlogFlowSlotRunInfoEntry 6 }
hpnicfUserlogAccessObjects OBJECT IDENTIFIER ::= { hpnicfUserlogObjects 3 }
hpnicfUserlogAccessVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BAS ACCESS LOG version. Currently only version 1 is developed."
::= { hpnicfUserlogAccessObjects 1 }
hpnicfUserlogAccessSyslog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
BAS ACCESS LOG format.
If 1, LOG format is sysLog;
If 0, LOG format is UDP packet.
UDP packet is the default format, and is recommended.
"
::= { hpnicfUserlogAccessObjects 2 }
hpnicfUserlogAccessSourceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Source IP address of BAS ACCESS LOG UDP packet."
::= { hpnicfUserlogAccessObjects 3 }
hpnicfUserlogAccessSlotCfgInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpnicfUserlogAccessSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS ACCESS LOG configuration information for the specified slot."
::= { hpnicfUserlogAccessObjects 4 }
hpnicfUserlogAccessSlotCfgInfoEntry OBJECT-TYPE
SYNTAX HpnicfUserlogAccessSlotCfgInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BAS ACCESS LOG Configuration Information Entry for a slot."
INDEX { hpnicfUserlogAccessCfgSlotNumber }
::= { hpnicfUserlogAccessSlotCfgInfoTable 1 }
HpnicfUserlogAccessSlotCfgInfoEntry ::=
SEQUENCE {
hpnicfUserlogAccessCfgSlotNumber
Integer32,
hpnicfUserlogAccessEnable
Integer32,
hpnicfUserlogAccessHostAddress
IpAddress,
hpnicfUserlogAccessUdpPort
Integer32
}
hpnicfUserlogAccessCfgSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify which slot is configured with BAS ACCESS LOG."
::= { hpnicfUserlogAccessSlotCfgInfoEntry 1 }
hpnicfUserlogAccessEnable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
The BAS ACCESS LOG feature Enable status.
If 1, BAS ACCESS LOG is enbled.
If 0, BAS ACCESS LOG is disabled.
"
::= { hpnicfUserlogAccessSlotCfgInfoEntry 2 }
hpnicfUserlogAccessHostAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of BAS ACCESS LOG server."
::= { hpnicfUserlogAccessSlotCfgInfoEntry 3 }
hpnicfUserlogAccessUdpPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP Port Number of BAS ACCESS LOG UDP packet."
::= { hpnicfUserlogAccessSlotCfgInfoEntry 4 }
hpnicfUserlogAccessSlotRunInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF HpnicfUserlogAccessSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of BAS ACCESS LOG running information for the specified slot."
::= { hpnicfUserlogAccessObjects 5 }
hpnicfUserlogAccessSlotRunInfoEntry OBJECT-TYPE
SYNTAX HpnicfUserlogAccessSlotRunInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Running Information Entry for a slot."
INDEX { hpnicfUserlogAccessRunSlotNumber }
::= { hpnicfUserlogAccessSlotRunInfoTable 1 }
HpnicfUserlogAccessSlotRunInfoEntry ::=
SEQUENCE {
hpnicfUserlogAccessRunSlotNumber
Integer32,
hpnicfUserlogAccessTotalEntries
Counter32,
hpnicfUserlogAccessTotalPackets
Counter32,
hpnicfUserlogAccessFailedEntries
Counter32,
hpnicfUserlogAccessFailedPackets
Counter32,
hpnicfUserlogAccessClearRunStat
Integer32
}
hpnicfUserlogAccessRunSlotNumber OBJECT-TYPE
SYNTAX Integer32 (0..15)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slot number. Specify on which slot the BAS ACCESS LOG statistics displayed."
::= { hpnicfUserlogAccessSlotRunInfoEntry 1 }
hpnicfUserlogAccessTotalEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS ACCESS Records which are logged."
::= { hpnicfUserlogAccessSlotRunInfoEntry 2 }
hpnicfUserlogAccessTotalPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of ACCESS LOG UDP packet generated by the router."
::= { hpnicfUserlogAccessSlotRunInfoEntry 3 }
hpnicfUserlogAccessFailedEntries OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS ACCESS entries failed in outputting."
::= { hpnicfUserlogAccessSlotRunInfoEntry 4 }
hpnicfUserlogAccessFailedPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of BAS ACCESS LOG UDP packet failed in outputting."
::= { hpnicfUserlogAccessSlotRunInfoEntry 5 }
hpnicfUserlogAccessClearRunStat OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"
Clear the running statistics for ACCESS LOG. Write-only.
If 1, the running statistics for ACCESS LOG is resetted.
Other value is invalid.
"
::= { hpnicfUserlogAccessSlotRunInfoEntry 6 }
hpnicfUserlogNotifications OBJECT IDENTIFIER ::= { hpnicfUserLogMIB 2 }
hpnicfUserlogConformance OBJECT IDENTIFIER ::= { hpnicfUserLogMIB 3 }
hpnicfUserlogCompliances OBJECT IDENTIFIER ::= { hpnicfUserlogConformance 1 }
hpnicfUserlogCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement the
Userlog mib."
MODULE -- this module
MANDATORY-GROUPS { hpnicfUserlogMandatoryGroup }
::= { hpnicfUserlogCompliances 1 }
hpnicfUserlogGroups OBJECT IDENTIFIER ::= { hpnicfUserlogConformance 2 }
hpnicfUserlogMandatoryGroup OBJECT-GROUP
OBJECTS { hpnicfUserlogNatEnable, hpnicfUserlogNatHostAddress, hpnicfUserlogNatUdpPort,
hpnicfUserlogFlowEnable, hpnicfUserlogFlowHostAddress, hpnicfUserlogFlowUdpPort,
hpnicfUserlogAccessEnable, hpnicfUserlogAccessHostAddress, hpnicfUserlogAccessUdpPort
}
STATUS current
DESCRIPTION
"A collection of objects providing mandatory Userlog information."
::= { hpnicfUserlogGroups 1 }
hpnicfUserlogConfigGroup OBJECT-GROUP
OBJECTS { hpnicfUserlogNatVersion, hpnicfUserlogNatSyslog, hpnicfUserlogNatSourceIP,
hpnicfUserlogNatFlowBegin, hpnicfUserlogNatActiveTime, hpnicfUserlogNatCfgSlotNumber,
hpnicfUserlogNatEnable, hpnicfUserlogNatAclNumber, hpnicfUserlogNatHostAddress,
hpnicfUserlogNatUdpPort, hpnicfUserlogFlowVersion, hpnicfUserlogFlowSyslog,
hpnicfUserlogFlowSourceIP, hpnicfUserlogFlowFlowBegin, hpnicfUserlogFlowActiveTime,
hpnicfUserlogFlowCfgSlotNumber, hpnicfUserlogFlowEnable, hpnicfUserlogFlowAclNumber,
hpnicfUserlogFlowHostAddress, hpnicfUserlogFlowUdpPort, hpnicfUserlogAccessVersion,
hpnicfUserlogAccessSyslog, hpnicfUserlogAccessSourceIP, hpnicfUserlogAccessCfgSlotNumber,
hpnicfUserlogAccessEnable, hpnicfUserlogAccessHostAddress, hpnicfUserlogAccessUdpPort
}
STATUS current
DESCRIPTION
"All configurable parameters of Userlog feature."
::= { hpnicfUserlogGroups 2 }
hpnicfUserlogInfoGroup OBJECT-GROUP
OBJECTS { hpnicfUserlogNatTotalEntries, hpnicfUserlogNatTotalPackets,
hpnicfUserlogNatFailedEntries, hpnicfUserlogNatFailedPackets,
hpnicfUserlogFlowTotalEntries, hpnicfUserlogFlowTotalPackets,
hpnicfUserlogFlowFailedEntries, hpnicfUserlogFlowFailedPackets,
hpnicfUserlogAccessTotalEntries, hpnicfUserlogAccessTotalPackets,
hpnicfUserlogAccessFailedEntries, hpnicfUserlogAccessFailedPackets
}
STATUS current
DESCRIPTION
"All running information of Userlog feature."
::= { hpnicfUserlogGroups 3 }
END