-- ================================================================= -- Copyright (c) 2010-2013 Hewlett-Packard Development Company, L.P. -- -- Description:This MIB file is used for management of userlog -- information. -- Reference: -- Version: V1.1 -- History: -- V1.0 -- 31st Mar 2003 -- tianli, initial version -- V1.1 2005-07-05 -- Modify value range of hpnicfUserlogNatAclNumber and hpnicfUserlogFlowAclNumber -- by tanbo02122. -- Update file format by gaolong. -- ================================================================= HPN-ICF-USERLOG-MIB DEFINITIONS ::= BEGIN IMPORTS hpnicfRhw FROM HPN-ICF-OID-MIB OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF IpAddress, Integer32, Counter32, OBJECT-TYPE, MODULE-IDENTITY FROM SNMPv2-SMI; hpnicfUserLogMIB MODULE-IDENTITY LAST-UPDATED "200304100000Z" -- April 10, 2003 at 00:00 GMT ORGANIZATION "" CONTACT-INFO "" DESCRIPTION "The HPN-ICF-USERLOG-MIB contains objects to Manage configuration and Monitor running state for userlog feature." ::= { hpnicfRhw 18 } hpnicfUserlogObjects OBJECT IDENTIFIER ::= { hpnicfUserLogMIB 1 } hpnicfUserlogNatObjects OBJECT IDENTIFIER ::= { hpnicfUserlogObjects 1 } hpnicfUserlogNatVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "NAT LOG version. Currently only version 1 is developed." ::= { hpnicfUserlogNatObjects 1 } hpnicfUserlogNatSyslog OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " NAT LOG format. If 1, LOG format is sysLog. If 0, LOG format is UDP packet. UDP packet is the default format, and is recommended. " ::= { hpnicfUserlogNatObjects 2 } hpnicfUserlogNatSourceIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The Source IP address of NAT LOG UDP packet." ::= { hpnicfUserlogNatObjects 3 } hpnicfUserlogNatFlowBegin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Log the NAT flow when it is created. If 1, this function is enabled. If 0, this function is disabled. This function will be used when real-time monitor required. " ::= { hpnicfUserlogNatObjects 4 } hpnicfUserlogNatActiveTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The active time for long-time existed NAT flow. Unit: minute. Range: 10 minutes ~ 120 minutes. When setting it, NAT flow can be logged after an interval of active time. This function will be used when real-time monitor required. The default value 0 means real-time monitor function is disabled. " ::= { hpnicfUserlogNatObjects 5 } hpnicfUserlogNatSlotCfgInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfUserlogNatSlotCfgInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of NAT LOG configuration information for the specified slot." ::= { hpnicfUserlogNatObjects 6 } hpnicfUserlogNatSlotCfgInfoEntry OBJECT-TYPE SYNTAX HpnicfUserlogNatSlotCfgInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NAT LOG Configuration Information Entry for a slot." INDEX { hpnicfUserlogNatCfgSlotNumber } ::= { hpnicfUserlogNatSlotCfgInfoTable 1 } HpnicfUserlogNatSlotCfgInfoEntry ::= SEQUENCE { hpnicfUserlogNatCfgSlotNumber Integer32, hpnicfUserlogNatEnable Integer32, hpnicfUserlogNatAclNumber Integer32, hpnicfUserlogNatHostAddress IpAddress, hpnicfUserlogNatUdpPort Integer32 } hpnicfUserlogNatCfgSlotNumber OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. Specify which slot is configured with NAT LOG. " ::= { hpnicfUserlogNatSlotCfgInfoEntry 1 } hpnicfUserlogNatEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The NAT LOG feature Enable status. If 1, NAT LOG is enbled. If 0, NAT LOG is disabled. " ::= { hpnicfUserlogNatSlotCfgInfoEntry 2 } hpnicfUserlogNatAclNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Access-list number. The value 0 means no ACL is specified. Only when NAT LOG is enabled, can ACL be configured. Only NAT flow which match the ACL will be logged. " ::= { hpnicfUserlogNatSlotCfgInfoEntry 3 } hpnicfUserlogNatHostAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of NAT LOG server. " ::= { hpnicfUserlogNatSlotCfgInfoEntry 4 } hpnicfUserlogNatUdpPort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The UDP Port Number of NAT LOG UDP packet." ::= { hpnicfUserlogNatSlotCfgInfoEntry 5 } hpnicfUserlogNatSlotRunInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfUserlogNatSlotRunInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of NAT LOG running information for the specified slot." ::= { hpnicfUserlogNatObjects 7 } hpnicfUserlogNatSlotRunInfoEntry OBJECT-TYPE SYNTAX HpnicfUserlogNatSlotRunInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "NAT LOG Running Information Entry for a slot." INDEX { hpnicfUserlogNatRunSlotNumber } ::= { hpnicfUserlogNatSlotRunInfoTable 1 } HpnicfUserlogNatSlotRunInfoEntry ::= SEQUENCE { hpnicfUserlogNatRunSlotNumber Integer32, hpnicfUserlogNatTotalEntries Counter32, hpnicfUserlogNatTotalPackets Counter32, hpnicfUserlogNatFailedEntries Counter32, hpnicfUserlogNatFailedPackets Counter32, hpnicfUserlogNatClearRunStat Integer32 } hpnicfUserlogNatRunSlotNumber OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. Specify on which slot the NAT LOG statistics displayed." ::= { hpnicfUserlogNatSlotRunInfoEntry 1 } hpnicfUserlogNatTotalEntries OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of NAT flow entries which are logged." ::= { hpnicfUserlogNatSlotRunInfoEntry 2 } hpnicfUserlogNatTotalPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of NAT LOG UDP packets generated by the router." ::= { hpnicfUserlogNatSlotRunInfoEntry 3 } hpnicfUserlogNatFailedEntries OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of NAT flow entries failed in outputting." ::= { hpnicfUserlogNatSlotRunInfoEntry 4 } hpnicfUserlogNatFailedPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of NAT LOG UDP packets failed in outputting." ::= { hpnicfUserlogNatSlotRunInfoEntry 5 } hpnicfUserlogNatClearRunStat OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Clear the running statistics for NAT LOG. Write-only. If 1, the running statistics for NAT LOG is resetted. Other value is invalid. " ::= { hpnicfUserlogNatSlotRunInfoEntry 6 } hpnicfUserlogFlowObjects OBJECT IDENTIFIER ::= { hpnicfUserlogObjects 2 } hpnicfUserlogFlowVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "BAS FLOW LOG version. Currently only version 1 is developed." ::= { hpnicfUserlogFlowObjects 1 } hpnicfUserlogFlowSyslog OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " BAS FLOW LOG format. If 1, LOG format is sysLog. If 0, LOG format is UDP packet. UDP packet is the default format, and is recommended. " ::= { hpnicfUserlogFlowObjects 2 } hpnicfUserlogFlowSourceIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The Source IP address of BAS FLOW LOG UDP packet." ::= { hpnicfUserlogFlowObjects 3 } hpnicfUserlogFlowFlowBegin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Log the BAS flow when it is created. If 1, this function is enabled. If 0, this function is disabled. This function will be used when real-time monitor required. " ::= { hpnicfUserlogFlowObjects 4 } hpnicfUserlogFlowActiveTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The active time for long-time existed BAS flow. Unit: minute. Range: 10 minutes ~ 120 minutes. When setting it, BAS flow can be logged after an internal of active time. This function will be used when real-time monitor required. The default value 0 means real-time monitor function is disabled. " ::= { hpnicfUserlogFlowObjects 5 } hpnicfUserlogFlowSlotCfgInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfUserlogFlowSlotCfgInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of BAS FLOW LOG configuration information for the specified slot." ::= { hpnicfUserlogFlowObjects 6 } hpnicfUserlogFlowSlotCfgInfoEntry OBJECT-TYPE SYNTAX HpnicfUserlogFlowSlotCfgInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BAS FLOW LOG Configuration Information Entry for a slot." INDEX { hpnicfUserlogFlowCfgSlotNumber } ::= { hpnicfUserlogFlowSlotCfgInfoTable 1 } HpnicfUserlogFlowSlotCfgInfoEntry ::= SEQUENCE { hpnicfUserlogFlowCfgSlotNumber Integer32, hpnicfUserlogFlowEnable Integer32, hpnicfUserlogFlowAclNumber Integer32, hpnicfUserlogFlowHostAddress IpAddress, hpnicfUserlogFlowUdpPort Integer32 } hpnicfUserlogFlowCfgSlotNumber OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. Specify which slot is configured with BAS FLOW LOG." ::= { hpnicfUserlogFlowSlotCfgInfoEntry 1 } hpnicfUserlogFlowEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The BAS FLOW LOG feature Enable status. If 1, BAS FLOW LOG is enbled. If 0, BAS FLOW LOG is disabled. " ::= { hpnicfUserlogFlowSlotCfgInfoEntry 2 } hpnicfUserlogFlowAclNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Access-list number. The value 0 means no ACL is specified. Only when BAS FLOW LOG is enabled, can ACL be configured. Only BAS flow which match the ACL will be logged. " ::= { hpnicfUserlogFlowSlotCfgInfoEntry 3 } hpnicfUserlogFlowHostAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of BAS FLOW LOG server. " ::= { hpnicfUserlogFlowSlotCfgInfoEntry 4 } hpnicfUserlogFlowUdpPort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The UDP Port Number of BAS FLOW LOG UDP packet." ::= { hpnicfUserlogFlowSlotCfgInfoEntry 5 } hpnicfUserlogFlowSlotRunInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfUserlogFlowSlotRunInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of BAS FLOW LOG running information for the specified slot." ::= { hpnicfUserlogFlowObjects 7 } hpnicfUserlogFlowSlotRunInfoEntry OBJECT-TYPE SYNTAX HpnicfUserlogFlowSlotRunInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Running Information Entry for a slot." INDEX { hpnicfUserlogFlowRunSlotNumber } ::= { hpnicfUserlogFlowSlotRunInfoTable 1 } HpnicfUserlogFlowSlotRunInfoEntry ::= SEQUENCE { hpnicfUserlogFlowRunSlotNumber Integer32, hpnicfUserlogFlowTotalEntries Counter32, hpnicfUserlogFlowTotalPackets Counter32, hpnicfUserlogFlowFailedEntries Counter32, hpnicfUserlogFlowFailedPackets Counter32, hpnicfUserlogFlowClearRunStat Integer32 } hpnicfUserlogFlowRunSlotNumber OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. Specify on which slot the BAS FLOW LOG statistics displayed." ::= { hpnicfUserlogFlowSlotRunInfoEntry 1 } hpnicfUserlogFlowTotalEntries OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of BAS FLOW Entries which are logged." ::= { hpnicfUserlogFlowSlotRunInfoEntry 2 } hpnicfUserlogFlowTotalPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of FLOW LOG UDP packet generated by the router." ::= { hpnicfUserlogFlowSlotRunInfoEntry 3 } hpnicfUserlogFlowFailedEntries OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of BAS FLOW entries failed in outputting. " ::= { hpnicfUserlogFlowSlotRunInfoEntry 4 } hpnicfUserlogFlowFailedPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of BAS FLOW LOG UDP packet failed in outputting." ::= { hpnicfUserlogFlowSlotRunInfoEntry 5 } hpnicfUserlogFlowClearRunStat OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Clear the running statistics for FLOW LOG. Write-only. If 1, the running statistics for FLOW LOG is resetted. Other value is invalid. " ::= { hpnicfUserlogFlowSlotRunInfoEntry 6 } hpnicfUserlogAccessObjects OBJECT IDENTIFIER ::= { hpnicfUserlogObjects 3 } hpnicfUserlogAccessVersion OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "BAS ACCESS LOG version. Currently only version 1 is developed." ::= { hpnicfUserlogAccessObjects 1 } hpnicfUserlogAccessSyslog OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " BAS ACCESS LOG format. If 1, LOG format is sysLog; If 0, LOG format is UDP packet. UDP packet is the default format, and is recommended. " ::= { hpnicfUserlogAccessObjects 2 } hpnicfUserlogAccessSourceIP OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The Source IP address of BAS ACCESS LOG UDP packet." ::= { hpnicfUserlogAccessObjects 3 } hpnicfUserlogAccessSlotCfgInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfUserlogAccessSlotCfgInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of BAS ACCESS LOG configuration information for the specified slot." ::= { hpnicfUserlogAccessObjects 4 } hpnicfUserlogAccessSlotCfgInfoEntry OBJECT-TYPE SYNTAX HpnicfUserlogAccessSlotCfgInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BAS ACCESS LOG Configuration Information Entry for a slot." INDEX { hpnicfUserlogAccessCfgSlotNumber } ::= { hpnicfUserlogAccessSlotCfgInfoTable 1 } HpnicfUserlogAccessSlotCfgInfoEntry ::= SEQUENCE { hpnicfUserlogAccessCfgSlotNumber Integer32, hpnicfUserlogAccessEnable Integer32, hpnicfUserlogAccessHostAddress IpAddress, hpnicfUserlogAccessUdpPort Integer32 } hpnicfUserlogAccessCfgSlotNumber OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. Specify which slot is configured with BAS ACCESS LOG." ::= { hpnicfUserlogAccessSlotCfgInfoEntry 1 } hpnicfUserlogAccessEnable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " The BAS ACCESS LOG feature Enable status. If 1, BAS ACCESS LOG is enbled. If 0, BAS ACCESS LOG is disabled. " ::= { hpnicfUserlogAccessSlotCfgInfoEntry 2 } hpnicfUserlogAccessHostAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "The IP address of BAS ACCESS LOG server." ::= { hpnicfUserlogAccessSlotCfgInfoEntry 3 } hpnicfUserlogAccessUdpPort OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "The UDP Port Number of BAS ACCESS LOG UDP packet." ::= { hpnicfUserlogAccessSlotCfgInfoEntry 4 } hpnicfUserlogAccessSlotRunInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfUserlogAccessSlotRunInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of BAS ACCESS LOG running information for the specified slot." ::= { hpnicfUserlogAccessObjects 5 } hpnicfUserlogAccessSlotRunInfoEntry OBJECT-TYPE SYNTAX HpnicfUserlogAccessSlotRunInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Running Information Entry for a slot." INDEX { hpnicfUserlogAccessRunSlotNumber } ::= { hpnicfUserlogAccessSlotRunInfoTable 1 } HpnicfUserlogAccessSlotRunInfoEntry ::= SEQUENCE { hpnicfUserlogAccessRunSlotNumber Integer32, hpnicfUserlogAccessTotalEntries Counter32, hpnicfUserlogAccessTotalPackets Counter32, hpnicfUserlogAccessFailedEntries Counter32, hpnicfUserlogAccessFailedPackets Counter32, hpnicfUserlogAccessClearRunStat Integer32 } hpnicfUserlogAccessRunSlotNumber OBJECT-TYPE SYNTAX Integer32 (0..15) MAX-ACCESS read-only STATUS current DESCRIPTION "Slot number. Specify on which slot the BAS ACCESS LOG statistics displayed." ::= { hpnicfUserlogAccessSlotRunInfoEntry 1 } hpnicfUserlogAccessTotalEntries OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of BAS ACCESS Records which are logged." ::= { hpnicfUserlogAccessSlotRunInfoEntry 2 } hpnicfUserlogAccessTotalPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of ACCESS LOG UDP packet generated by the router." ::= { hpnicfUserlogAccessSlotRunInfoEntry 3 } hpnicfUserlogAccessFailedEntries OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of BAS ACCESS entries failed in outputting." ::= { hpnicfUserlogAccessSlotRunInfoEntry 4 } hpnicfUserlogAccessFailedPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of BAS ACCESS LOG UDP packet failed in outputting." ::= { hpnicfUserlogAccessSlotRunInfoEntry 5 } hpnicfUserlogAccessClearRunStat OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION " Clear the running statistics for ACCESS LOG. Write-only. If 1, the running statistics for ACCESS LOG is resetted. Other value is invalid. " ::= { hpnicfUserlogAccessSlotRunInfoEntry 6 } hpnicfUserlogNotifications OBJECT IDENTIFIER ::= { hpnicfUserLogMIB 2 } hpnicfUserlogConformance OBJECT IDENTIFIER ::= { hpnicfUserLogMIB 3 } hpnicfUserlogCompliances OBJECT IDENTIFIER ::= { hpnicfUserlogConformance 1 } hpnicfUserlogCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for entities which implement the Userlog mib." MODULE -- this module MANDATORY-GROUPS { hpnicfUserlogMandatoryGroup } ::= { hpnicfUserlogCompliances 1 } hpnicfUserlogGroups OBJECT IDENTIFIER ::= { hpnicfUserlogConformance 2 } hpnicfUserlogMandatoryGroup OBJECT-GROUP OBJECTS { hpnicfUserlogNatEnable, hpnicfUserlogNatHostAddress, hpnicfUserlogNatUdpPort, hpnicfUserlogFlowEnable, hpnicfUserlogFlowHostAddress, hpnicfUserlogFlowUdpPort, hpnicfUserlogAccessEnable, hpnicfUserlogAccessHostAddress, hpnicfUserlogAccessUdpPort } STATUS current DESCRIPTION "A collection of objects providing mandatory Userlog information." ::= { hpnicfUserlogGroups 1 } hpnicfUserlogConfigGroup OBJECT-GROUP OBJECTS { hpnicfUserlogNatVersion, hpnicfUserlogNatSyslog, hpnicfUserlogNatSourceIP, hpnicfUserlogNatFlowBegin, hpnicfUserlogNatActiveTime, hpnicfUserlogNatCfgSlotNumber, hpnicfUserlogNatEnable, hpnicfUserlogNatAclNumber, hpnicfUserlogNatHostAddress, hpnicfUserlogNatUdpPort, hpnicfUserlogFlowVersion, hpnicfUserlogFlowSyslog, hpnicfUserlogFlowSourceIP, hpnicfUserlogFlowFlowBegin, hpnicfUserlogFlowActiveTime, hpnicfUserlogFlowCfgSlotNumber, hpnicfUserlogFlowEnable, hpnicfUserlogFlowAclNumber, hpnicfUserlogFlowHostAddress, hpnicfUserlogFlowUdpPort, hpnicfUserlogAccessVersion, hpnicfUserlogAccessSyslog, hpnicfUserlogAccessSourceIP, hpnicfUserlogAccessCfgSlotNumber, hpnicfUserlogAccessEnable, hpnicfUserlogAccessHostAddress, hpnicfUserlogAccessUdpPort } STATUS current DESCRIPTION "All configurable parameters of Userlog feature." ::= { hpnicfUserlogGroups 2 } hpnicfUserlogInfoGroup OBJECT-GROUP OBJECTS { hpnicfUserlogNatTotalEntries, hpnicfUserlogNatTotalPackets, hpnicfUserlogNatFailedEntries, hpnicfUserlogNatFailedPackets, hpnicfUserlogFlowTotalEntries, hpnicfUserlogFlowTotalPackets, hpnicfUserlogFlowFailedEntries, hpnicfUserlogFlowFailedPackets, hpnicfUserlogAccessTotalEntries, hpnicfUserlogAccessTotalPackets, hpnicfUserlogAccessFailedEntries, hpnicfUserlogAccessFailedPackets } STATUS current DESCRIPTION "All running information of Userlog feature." ::= { hpnicfUserlogGroups 3 } END