-- Copyright (c) 2010-2013 Hewlett-Packard Development Company, L.P.
|
|
--
|
|
-- Description: MPLSOAM PS(protection switching) MIB
|
|
-- Reference:
|
|
-- Version: V1.0
|
|
-- History:
|
|
-- V1.0 2007-03-31 Created by LiXufu ID: 05023
|
|
-- ==================================================================
|
|
HPN-ICF-MPLSOAM-PS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
hpnicfCommon
|
|
FROM HPN-ICF-OID-MIB
|
|
Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
TruthValue, RowStatus
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
hpnicfMplsOamPs MODULE-IDENTITY
|
|
LAST-UPDATED "200703310000Z" -- March 31, 2007 at 00:00 GMT
|
|
ORGANIZATION
|
|
""
|
|
CONTACT-INFO
|
|
""
|
|
DESCRIPTION
|
|
"This MIB contains objects to configure mpls
|
|
protect-switch module."
|
|
::= { hpnicfCommon 80 }
|
|
|
|
|
|
-- ==================================================================
|
|
--
|
|
-- ======================= definition begin =========================
|
|
--
|
|
-- ==================================================================
|
|
hpnicfMplsOamPsScalarGroup OBJECT IDENTIFIER ::= { hpnicfMplsOamPs 1 }
|
|
|
|
hpnicfMplsOamPsTrapOpen OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether mpls protect-switch trap is globally enabled.
|
|
false: disable;
|
|
true: enable"
|
|
DEFVAL { false }
|
|
::= { hpnicfMplsOamPsScalarGroup 1 }
|
|
|
|
hpnicfMplsOamPsTable OBJECT IDENTIFIER ::= { hpnicfMplsOamPs 2 }
|
|
|
|
hpnicfMplsPsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HpnicfMplsPsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table specifies per-protection-group MPLS PS
|
|
capability and associated information."
|
|
::= { hpnicfMplsOamPsTable 1 }
|
|
|
|
hpnicfMplsPsEntry OBJECT-TYPE
|
|
SYNTAX HpnicfMplsPsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in this table is created by an LSR for every
|
|
protection group capable of supporting mpls ps."
|
|
INDEX
|
|
{
|
|
hpnicfMplsPsIndex
|
|
}
|
|
::= { hpnicfMplsPsTable 1 }
|
|
|
|
HpnicfMplsPsEntry ::= SEQUENCE
|
|
{
|
|
hpnicfMplsPsIndex Integer32,
|
|
hpnicfMplsPsGroupID Integer32,
|
|
hpnicfMplsPsWorkLspName OCTET STRING,
|
|
hpnicfMplsPsProtectLspName OCTET STRING,
|
|
hpnicfMplsPsRevertiveMode Integer32,
|
|
hpnicfMplsPsWTR Integer32,
|
|
hpnicfMplsPsHoldOff Integer32,
|
|
hpnicfMplsPsSwitchCondition Integer32,
|
|
hpnicfMplsPsWorkLspDetectState Integer32,
|
|
hpnicfMplsPsWorkLspUpDownState Integer32,
|
|
hpnicfMplsPsProtLspDetectState Integer32,
|
|
hpnicfMplsPsProtLspUpDownState Integer32,
|
|
hpnicfMplsPsSwitchResult Integer32,
|
|
hpnicfMplsPsRowStatus RowStatus
|
|
}
|
|
|
|
hpnicfMplsPsIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a unique index for an entry in the mplspsEntry."
|
|
::= { hpnicfMplsPsEntry 1 }
|
|
|
|
hpnicfMplsPsGroupID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a unique group id for an entry in the mplspsEntry.
|
|
One protect-switch group is composed of one working static-lsp
|
|
and one protection static-lsp."
|
|
::= { hpnicfMplsPsEntry 2 }
|
|
|
|
hpnicfMplsPsWorkLspName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the working static-lsp."
|
|
::= { hpnicfMplsPsEntry 3 }
|
|
|
|
hpnicfMplsPsProtectLspName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the protection static-lsp."
|
|
::= { hpnicfMplsPsEntry 4 }
|
|
|
|
hpnicfMplsPsRevertiveMode OBJECT-TYPE
|
|
SYNTAX Integer32(1..2)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Revertive mode is a protection switching mode where revertive
|
|
action (switch back to the working LSP) is taken after the
|
|
working LSP is repaired. And switching does not occur in a
|
|
non-revertive mode.
|
|
1: revertive;
|
|
2: non-revertive;"
|
|
::= { hpnicfMplsPsEntry 5 }
|
|
|
|
hpnicfMplsPsWTR OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "30s"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wait to Restore timer is only applicable for the revertive mode
|
|
and applies to a working LSP, it prevents reversion back to
|
|
select the working LSP until the Wait to Restore timer has
|
|
expired.
|
|
The default value is 12 minutes. step is 30s."
|
|
::= { hpnicfMplsPsEntry 6 }
|
|
|
|
hpnicfMplsPsHoldOff OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "100ms"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time between declaration of signal degrade or signal fail,
|
|
and the initialization of the protection switching algorithm.
|
|
Step is 100ms, maximum is 10s."
|
|
::= { hpnicfMplsPsEntry 7 }
|
|
|
|
hpnicfMplsPsSwitchCondition OBJECT-TYPE
|
|
SYNTAX Integer32(1..9)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current switch condition of the protection group.
|
|
1: clear, this command clears all of the externally
|
|
initiated switch commands listed below;
|
|
2: lockout of protection, fix the selector position on the
|
|
working LSP, Prevents the selector from switching to the
|
|
protection LSP when it is selecting the working LSP.
|
|
Switches the selector from the protection to the working LSP
|
|
when it is selecting the protection LSP;
|
|
3: forced protection, switches the selector from the working LSP
|
|
to the protection LSP (unless a higher priority switch
|
|
request (i.e., LoP) is in effect);
|
|
4: signal fail, for 1:1, Signal Fail (SF) is declared when the
|
|
source of the protection domain enters the Defect State by
|
|
receiving a BDI packet (from the return LSP or out of band).
|
|
5: manual switch for working-lsp, switches the selector from the
|
|
working LSP to the protection LSP (unless an equal or higher
|
|
priority switch request (i.e., LoP, FS, SF or MS) is in
|
|
effect);
|
|
6: manual switch for protection-lsp, switches the selector from
|
|
the protection LSP to the working LSP (unless an equal or
|
|
higher priority switch request (i.e., LoP, FS, SF or MS) is
|
|
in effect).
|
|
7: WTR-timer, a configurable timer which is used to delay before
|
|
reversion;
|
|
8: HoldOff-timer, the time between declaration of signal degrade
|
|
or signal fail, and the initialization of the protection
|
|
switching algorithm;
|
|
9: Others;
|
|
The pripority of the commands are:
|
|
clear > lockout of protection > force switch > manual switch for working
|
|
lsp = manual switch for protection lsp"
|
|
::= { hpnicfMplsPsEntry 8 }
|
|
|
|
hpnicfMplsPsWorkLspDetectState OBJECT-TYPE
|
|
SYNTAX Integer32(1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of working static-lsp state in one protection group,
|
|
whether it is in defect:
|
|
1: it is out of defect;
|
|
2: it enters defect."
|
|
::= { hpnicfMplsPsEntry 9 }
|
|
|
|
hpnicfMplsPsWorkLspUpDownState OBJECT-TYPE
|
|
SYNTAX Integer32(1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of working static-lsp state in one protection group,
|
|
whether it is up or down:
|
|
1: it is in up state;
|
|
2: it is in down state."
|
|
::= { hpnicfMplsPsEntry 10 }
|
|
|
|
hpnicfMplsPsProtLspDetectState OBJECT-TYPE
|
|
SYNTAX Integer32(1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of protection static-lsp state in one protection group,
|
|
whether it is in detection:
|
|
1: it is out of defect;
|
|
2: it enters defect."
|
|
::= { hpnicfMplsPsEntry 11 }
|
|
|
|
hpnicfMplsPsProtLspUpDownState OBJECT-TYPE
|
|
SYNTAX Integer32(1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of protection static-lsp state in one protection group,
|
|
whether it is up or down:
|
|
1: it is in up state;
|
|
2: it is in down state."
|
|
::= { hpnicfMplsPsEntry 12 }
|
|
|
|
hpnicfMplsPsSwitchResult OBJECT-TYPE
|
|
SYNTAX Integer32(1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Which tunnel is used to transfer the data stream.
|
|
1: working static-lsp;
|
|
2: protection static-lsp."
|
|
::= { hpnicfMplsPsEntry 13 }
|
|
|
|
hpnicfMplsPsRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is responsible for managing the creation,
|
|
deletion and modification of rows, which support active
|
|
status and CreatAndGo, destroy operation.
|
|
To create a new row, hpnicfMplsPsGroupID, hpnicfMplsPsWorkLspName,
|
|
hpnicfMplsPsProtectLspName, hpnicfMplsPsRevertiveMode, hpnicfMplsPsWTR
|
|
and hpnicfMplsPsHoldOff must be specified."
|
|
::= { hpnicfMplsPsEntry 14 }
|
|
|
|
hpnicfMplsOamPsNotifications OBJECT IDENTIFIER ::= { hpnicfMplsOamPs 3 }
|
|
|
|
hpnicfMplsPsSwitchPtoW NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hpnicfMplsPsWorkLspName,
|
|
hpnicfMplsPsProtectLspName,
|
|
hpnicfMplsPsSwitchResult
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is generated when switching from
|
|
protection-lsp to working-lsp occured."
|
|
::= { hpnicfMplsOamPsNotifications 1 }
|
|
|
|
hpnicfMplsPsSwitchWtoP NOTIFICATION-TYPE
|
|
OBJECTS
|
|
{
|
|
hpnicfMplsPsWorkLspName,
|
|
hpnicfMplsPsProtectLspName,
|
|
hpnicfMplsPsSwitchResult
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This notification is generated when switching from woking-lsp
|
|
to protection-lsp occured."
|
|
::= { hpnicfMplsOamPsNotifications 2 }
|
|
|
|
END
|