-- ================================================================== -- Copyright (c) 2010-2013 Hewlett-Packard Development Company, L.P. -- -- Description: MPLSOAM PS(protection switching) MIB -- Reference: -- Version: V1.0 -- History: -- V1.0 2007-03-31 Created by LiXufu ID: 05023 -- ================================================================== HPN-ICF-MPLSOAM-PS-MIB DEFINITIONS ::= BEGIN IMPORTS hpnicfCommon FROM HPN-ICF-OID-MIB Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI TruthValue, RowStatus FROM SNMPv2-TC; hpnicfMplsOamPs MODULE-IDENTITY LAST-UPDATED "200703310000Z" -- March 31, 2007 at 00:00 GMT ORGANIZATION "" CONTACT-INFO "" DESCRIPTION "This MIB contains objects to configure mpls protect-switch module." ::= { hpnicfCommon 80 } -- ================================================================== -- -- ======================= definition begin ========================= -- -- ================================================================== hpnicfMplsOamPsScalarGroup OBJECT IDENTIFIER ::= { hpnicfMplsOamPs 1 } hpnicfMplsOamPsTrapOpen OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Whether mpls protect-switch trap is globally enabled. false: disable; true: enable" DEFVAL { false } ::= { hpnicfMplsOamPsScalarGroup 1 } hpnicfMplsOamPsTable OBJECT IDENTIFIER ::= { hpnicfMplsOamPs 2 } hpnicfMplsPsTable OBJECT-TYPE SYNTAX SEQUENCE OF HpnicfMplsPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table specifies per-protection-group MPLS PS capability and associated information." ::= { hpnicfMplsOamPsTable 1 } hpnicfMplsPsEntry OBJECT-TYPE SYNTAX HpnicfMplsPsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in this table is created by an LSR for every protection group capable of supporting mpls ps." INDEX { hpnicfMplsPsIndex } ::= { hpnicfMplsPsTable 1 } HpnicfMplsPsEntry ::= SEQUENCE { hpnicfMplsPsIndex Integer32, hpnicfMplsPsGroupID Integer32, hpnicfMplsPsWorkLspName OCTET STRING, hpnicfMplsPsProtectLspName OCTET STRING, hpnicfMplsPsRevertiveMode Integer32, hpnicfMplsPsWTR Integer32, hpnicfMplsPsHoldOff Integer32, hpnicfMplsPsSwitchCondition Integer32, hpnicfMplsPsWorkLspDetectState Integer32, hpnicfMplsPsWorkLspUpDownState Integer32, hpnicfMplsPsProtLspDetectState Integer32, hpnicfMplsPsProtLspUpDownState Integer32, hpnicfMplsPsSwitchResult Integer32, hpnicfMplsPsRowStatus RowStatus } hpnicfMplsPsIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "This is a unique index for an entry in the mplspsEntry." ::= { hpnicfMplsPsEntry 1 } hpnicfMplsPsGroupID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create STATUS current DESCRIPTION "This is a unique group id for an entry in the mplspsEntry. One protect-switch group is composed of one working static-lsp and one protection static-lsp." ::= { hpnicfMplsPsEntry 2 } hpnicfMplsPsWorkLspName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "The name of the working static-lsp." ::= { hpnicfMplsPsEntry 3 } hpnicfMplsPsProtectLspName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-create STATUS current DESCRIPTION "The name of the protection static-lsp." ::= { hpnicfMplsPsEntry 4 } hpnicfMplsPsRevertiveMode OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-create STATUS current DESCRIPTION "Revertive mode is a protection switching mode where revertive action (switch back to the working LSP) is taken after the working LSP is repaired. And switching does not occur in a non-revertive mode. 1: revertive; 2: non-revertive;" ::= { hpnicfMplsPsEntry 5 } hpnicfMplsPsWTR OBJECT-TYPE SYNTAX Integer32 UNITS "30s" MAX-ACCESS read-create STATUS current DESCRIPTION "Wait to Restore timer is only applicable for the revertive mode and applies to a working LSP, it prevents reversion back to select the working LSP until the Wait to Restore timer has expired. The default value is 12 minutes. step is 30s." ::= { hpnicfMplsPsEntry 6 } hpnicfMplsPsHoldOff OBJECT-TYPE SYNTAX Integer32 UNITS "100ms" MAX-ACCESS read-create STATUS current DESCRIPTION "The time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm. Step is 100ms, maximum is 10s." ::= { hpnicfMplsPsEntry 7 } hpnicfMplsPsSwitchCondition OBJECT-TYPE SYNTAX Integer32(1..9) MAX-ACCESS read-create STATUS current DESCRIPTION "The current switch condition of the protection group. 1: clear, this command clears all of the externally initiated switch commands listed below; 2: lockout of protection, fix the selector position on the working LSP, Prevents the selector from switching to the protection LSP when it is selecting the working LSP. Switches the selector from the protection to the working LSP when it is selecting the protection LSP; 3: forced protection, switches the selector from the working LSP to the protection LSP (unless a higher priority switch request (i.e., LoP) is in effect); 4: signal fail, for 1:1, Signal Fail (SF) is declared when the source of the protection domain enters the Defect State by receiving a BDI packet (from the return LSP or out of band). 5: manual switch for working-lsp, switches the selector from the working LSP to the protection LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect); 6: manual switch for protection-lsp, switches the selector from the protection LSP to the working LSP (unless an equal or higher priority switch request (i.e., LoP, FS, SF or MS) is in effect). 7: WTR-timer, a configurable timer which is used to delay before reversion; 8: HoldOff-timer, the time between declaration of signal degrade or signal fail, and the initialization of the protection switching algorithm; 9: Others; The pripority of the commands are: clear > lockout of protection > force switch > manual switch for working lsp = manual switch for protection lsp" ::= { hpnicfMplsPsEntry 8 } hpnicfMplsPsWorkLspDetectState OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The state of working static-lsp state in one protection group, whether it is in defect: 1: it is out of defect; 2: it enters defect." ::= { hpnicfMplsPsEntry 9 } hpnicfMplsPsWorkLspUpDownState OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The state of working static-lsp state in one protection group, whether it is up or down: 1: it is in up state; 2: it is in down state." ::= { hpnicfMplsPsEntry 10 } hpnicfMplsPsProtLspDetectState OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The state of protection static-lsp state in one protection group, whether it is in detection: 1: it is out of defect; 2: it enters defect." ::= { hpnicfMplsPsEntry 11 } hpnicfMplsPsProtLspUpDownState OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "The state of protection static-lsp state in one protection group, whether it is up or down: 1: it is in up state; 2: it is in down state." ::= { hpnicfMplsPsEntry 12 } hpnicfMplsPsSwitchResult OBJECT-TYPE SYNTAX Integer32(1..2) MAX-ACCESS read-only STATUS current DESCRIPTION "Which tunnel is used to transfer the data stream. 1: working static-lsp; 2: protection static-lsp." ::= { hpnicfMplsPsEntry 13 } hpnicfMplsPsRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is responsible for managing the creation, deletion and modification of rows, which support active status and CreatAndGo, destroy operation. To create a new row, hpnicfMplsPsGroupID, hpnicfMplsPsWorkLspName, hpnicfMplsPsProtectLspName, hpnicfMplsPsRevertiveMode, hpnicfMplsPsWTR and hpnicfMplsPsHoldOff must be specified." ::= { hpnicfMplsPsEntry 14 } hpnicfMplsOamPsNotifications OBJECT IDENTIFIER ::= { hpnicfMplsOamPs 3 } hpnicfMplsPsSwitchPtoW NOTIFICATION-TYPE OBJECTS { hpnicfMplsPsWorkLspName, hpnicfMplsPsProtectLspName, hpnicfMplsPsSwitchResult } STATUS current DESCRIPTION "This notification is generated when switching from protection-lsp to working-lsp occured." ::= { hpnicfMplsOamPsNotifications 1 } hpnicfMplsPsSwitchWtoP NOTIFICATION-TYPE OBJECTS { hpnicfMplsPsWorkLspName, hpnicfMplsPsProtectLspName, hpnicfMplsPsSwitchResult } STATUS current DESCRIPTION "This notification is generated when switching from woking-lsp to protection-lsp occured." ::= { hpnicfMplsOamPsNotifications 2 } END