1311 lines
33 KiB
Plaintext

--
-- Eltex Enterprise Specific MIB: Structure of Management Information
--
-- Copyright (c) 2007-2009, Eltex Co
--
-- The contents of this document are subject to change without notice.
--
ELTEX-SMI DEFINITIONS ::= BEGIN
IMPORTS
enterprises,
MODULE-IDENTITY,
OBJECT-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Integer32
FROM SNMPv2-SMI
DisplayString,
TimeStamp
FROM SNMPv2-TC
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF;
eltex MODULE-IDENTITY
LAST-UPDATED "200906031500Z"
ORGANIZATION "Eltex Co"
CONTACT-INFO
"eltex@gcom.ru"
DESCRIPTION
"The Structure of Management Information for Eltex Networks."
::= { enterprises 34300 }
--
-- Eltex MIB tree structure
--
elHardware OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The root of eltex hardware OIDs."
::= { eltex 1 }
elSoftware OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The root of eltex software OIDs."
::= { eltex 2 }
eltrapGroup OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The root of eltex traps objects."
::= { eltex 3 }
-- define trap groups --
mc240AlarmTraps OBJECT IDENTIFIER ::= { eltrapGroup 3 }
-- define all traps ---- MC-240 traps --
mc240StreamAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 stream alarm trap. Severity: alert"
::= { mc240AlarmTraps 1 }
mc240SyncAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 sync alarm trap. Severity: warning"
::= { mc240AlarmTraps 2 }
mc240ss7LinkAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 ss7 link alarm trap. Severity: alert"
::= { mc240AlarmTraps 3 }
mc240ss7LinksetAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 ss7 linkset alarm trap. Severity: critical"
::= { mc240AlarmTraps 4 }
mc240FileAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 file alarm trap. Severity: critical"
::= { mc240AlarmTraps 5 }
mc240CardAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 card alarm trap. Severity: critical"
::= { mc240AlarmTraps 6 }
mxlDPSAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"mxl DSL DP system alarm trap"
::= { mc240AlarmTraps 7 }
mxlTELEAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"mxl DSL DP system alarm trap"
::= { mc240AlarmTraps 8 }
mc240UPSAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc240 UPS alarm trap"
::= { mc240AlarmTraps 9 }
mc240SensAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc240 sensor alarm trap (mcTrapExState = sensors bit mask, param1=temp,C, param2=Hum,%)"
::= { mc240AlarmTraps 10 }
-- ---- ---- ---- ---- ---- ---- MXA link alarm ---- ---- ---- ---- ---- ---- ---- --
dslamLinkDownTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"dslam link down trap (mcTrapExState = link state, param1 = ADSLport)"
::= { mc240AlarmTraps 11 }
-- MXA change adsl port Downstream rate alarm --
dslamDSRateAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport)"
::= { mc240AlarmTraps 12 }
-- MXA change adsl port Upstream rate alarm --
dslamUSRateAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport)"
::= { mc240AlarmTraps 13 }
-- ---- ---- ---- ---- ---- ---- ---- GePON ALARMS ---- ---- ---- ---- ---- ---- ---- ----
-- GePON ONU Authorization Alarm --
ponONUAuthAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Bad registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU')"
::= { mc240AlarmTraps 14 }
-- GePON Eth link Down --
ponEthAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Eth Link Down, mcTrapLParam1=Link Number, Description='GePON: Eth Link N down'"
::= { mc240AlarmTraps 15 }
-- GePON Optical link Event --
ponOpticalAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"The optical link N (mcTrapLParam1) has no active devices"
::= { mc240AlarmTraps 16 }
-- ---- ---- ---- ---- ---- ---- MXA ---- ---- ---- ---- ---- ---- ---- --
-- MXA overheat alarm --
dslamOverheatAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10)"
::= { mc240AlarmTraps 17 }
-- MXA power alarm --
dslamVoltageAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"when voltage deviation become more 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value )"
::= { mc240AlarmTraps 18 }
-- MXA session connect --
dslamSessionAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Trap sending when connection happen, mcTrapLParam1 - means connection from (0)-CLI (1)->Webs (2)->SNMP"
::= { mc240AlarmTraps 19 }
-- MXA Eth OperStatus --
dslamEthLinkAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Trap sending when switch port link DOWN, mcTrapLParam1 - means port num:
for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1;
for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1"
::= { mc240AlarmTraps 20 }
mc240OkTraps OBJECT IDENTIFIER ::= { eltrapGroup 4 }
mc240StreamOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 stream ok trap. Severity: alert"
::= { mc240OkTraps 1 }
mc240SyncOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 sync ok trap. Severity: warning"
::= { mc240OkTraps 2 }
mc240ss7LinkOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 ss7 link ok trap. Severity: alert"
::= { mc240OkTraps 3 }
mc240ss7LinksetOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 ss7 linkset ok trap. Severity: critical"
::= { mc240OkTraps 4 }
mc240FileOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 file ok trap. Severity: critical"
::= { mc240OkTraps 5 }
mc240CardOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc-240 card trap. Severity: critical"
::= { mc240OkTraps 6 }
mxlDPSOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"mxl DSL DP system alarm trap (normal state)"
::= { mc240OkTraps 7 }
mxlTELEOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"mxl DSL DP system alarm trap (normal state)"
::= { mc240OkTraps 8 }
mc240UPSOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc240 UPS alarm trap (normal state)"
::= { mc240OkTraps 9 }
mc240SensOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag}
STATUS current
DESCRIPTION
"mc240 sensor alarm trap (normal state)"
::= { mc240OkTraps 10 }
dslamLinkUpTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"dslam link up trap (mcTrapExState = link state == 0, param1 = ADSLport)"
::= { mc240OkTraps 11 }
dslamDSRateOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport)"
::= { mc240OkTraps 12 }
dslamUSRateOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport)"
::= { mc240OkTraps 13 }
-- PON ok traps --
ponONUAuthOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Normal registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU')"
::= { mc240OkTraps 14 }
ponEthOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Eth Link Up, mcTrapLParam1=Link Number, Description='GePON: Eth Link N up'"
::= { mc240OkTraps 15 }
ponOpticalOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"The optical link N (mcTrapLParam1) has M (mcTrapLParam2) active devices"
::= { mc240OkTraps 16 }
-- MXA
dslamOverheatOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10)"
::= { mc240OkTraps 17 }
dslamVoltageOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"when voltage deviation become less 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value )"
::= { mc240OkTraps 18 }
-- MXA session connect --
dslamSessionOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Trap sending when connection closed, mcTrapLParam1 - means disconnection from (0)-CLI (1)->Webs (2)->SNMP"
::= { mc240OkTraps 19 }
-- MXA Eth OperStatus --
dslamEthLinkOkTrap NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
"Trap sending when switch port link UP, mcTrapLParam1 - means port num:
for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1;
for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1"
::= { mc240OkTraps 20 }
mc240TrapTypes OBJECT IDENTIFIER ::= { eltrapGroup 5 }
-- trap properties
mcTrapExState OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"state (additional state)"
::= { mc240TrapTypes 1 }
mcTrapLParam1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"param-1 (slot or index)"
::= { mc240TrapTypes 2 }
mcTrapLParam2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"param-2 (port or index)"
::= { mc240TrapTypes 3 }
mcTrapLParam3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"param-3 (other index)"
::= { mc240TrapTypes 4 }
mcTrapID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID (pbx trap id)"
::= { mc240TrapTypes 5 }
mcTrapDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Alarm description"
::= { mc240TrapTypes 6 }
mcTrapRestoredAlarmID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If this restore event then here writed Alarm ID. If this alarm event then mcTrapRestoredAlarmID=0."
::= { mc240TrapTypes 7 }
mcTrapSyncType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of trap: 0 - Normal; 1 - Journal alarms; 2 - Active alarms"
::= { mc240TrapTypes 8 }
mcReservedFlag OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reserved flag"
::= { mc240TrapTypes 9 }
-- OMS operation status traps --
omsOperationAlarmTraps OBJECT IDENTIFIER ::= { eltrapGroup 20 }
omsOperationOkTraps OBJECT IDENTIFIER ::= { eltrapGroup 21 }
omsOperationCommandAlarm NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
" mcTrapLParam1 = command <upload=1, download=2, apply=3, confirm=4, save=5>;
mcTrapLParam2 = filetype <pattern=1, private=2, binary=3>
mcTrapDescr = Description of operarion:
DeviceName,
command <upload, download, apply, confirm, save>,
tftp host,
config filename,
status=Error,
cause of error"
::= { omsOperationAlarmTraps 1 }
omsOperationCommandOk NOTIFICATION-TYPE
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr}
STATUS current
DESCRIPTION
" mcTrapLParam1 = command <upload=1, download=2, apply=3, confirm=4, save=5>;
mcTrapLParam2 = filetype <pattern=1, private=2, binary=3>
mcTrapDescr = Description of operarion:
DeviceName,
command <upload, download, apply, confirm, save>,
tftp host,
config filename,
status=Ok"
::= { omsOperationOkTraps 1 }
---------------------------------------------------------------------------------------------------------------------------
----------------------------------------------- MP800MK Traps -------------------------------------------------------------
---------------------------------------------------------------------------------------------------------------------------
-- mp800mk ALARM traps
mp800mkAlarmTraps OBJECT IDENTIFIER ::= { eltrapGroup 8 }
-- MP status
mp800mkMPStatusAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"MP operation error."
::= {mp800mkAlarmTraps 1}
-- Input parameters
mp800mkInpParmAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Incorrect input parameters."
::= {mp800mkAlarmTraps 2}
-- UEP configuration
mp800mkUEPConfAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"UEP configuration error."
::= {mp800mkAlarmTraps 3}
-- Temperature measurement
mp800mkTMAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Temperature measurement error."
::= {mp800mkAlarmTraps 4}
-- AC voltage measurement
mp800mkACVMAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"ACV measurement error."
::= {mp800mkAlarmTraps 5}
-- Battery current measurement
mp800mkIbatMAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery current measurement error."
::= {mp800mkAlarmTraps 6}
-- Battery voltage measurement
mp800mkVbatMAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery voltage measurement error."
::= {mp800mkAlarmTraps 7}
-- Battery voltage control
mp800mkVbatChAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Can't change (increase or decrease) battery voltage."
::= {mp800mkAlarmTraps 8}
-- Release device status
mp800mkRlsDevAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Release device is off (battery disconnected)."
::= {mp800mkAlarmTraps 9}
-- Battery cell voltage spread
mp800mkDVcellAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery cell voltage spread is out of range."
::= {mp800mkAlarmTraps 10}
-- AC voltage
mp800mkACVAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"AC voltage is out of range."
::= {mp800mkAlarmTraps 11}
-- Battery charge status
mp800mkBatChargeAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery is close to total discharge."
::= {mp800mkAlarmTraps 12}
-- Load current
mp800mkIloadAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Load current is out of range."
::= {mp800mkAlarmTraps 13}
-- Battery charge current
mp800mkIbatChAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery charge current is too high."
::= {mp800mkAlarmTraps 14}
-- Power supply status
mp800mkSuppAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Power supply from battery."
::= {mp800mkAlarmTraps 15}
-- Battery disconnected?
mp800mkBatConnAlarmTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery is disconnected from MPs' output."
::= {mp800mkAlarmTraps 16}
-- mp800mk OK traps
mp800mkOkTraps OBJECT IDENTIFIER ::= { eltrapGroup 9 }
-- MP status
mp800mkMPStatusOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"MP operation OK."
::= {mp800mkOkTraps 1}
-- Input parameters
mp800mkInpParmOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Input parameters OK."
::= {mp800mkOkTraps 2}
-- UEP configuration
mp800mkUEPConfOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"UEP configuration OK."
::= {mp800mkOkTraps 3}
-- Temperature measurement
mp800mkTMOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Temperature measurement OK."
::= {mp800mkOkTraps 4}
-- AC voltage measurement
mp800mkACVMOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"ACV measurement OK."
::= {mp800mkOkTraps 5}
-- Battery current measurement
mp800mkIbatMOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery current measurement OK."
::= {mp800mkOkTraps 6}
-- Battery voltage measurement
mp800mkVbatMOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery voltage measurement OK."
::= {mp800mkOkTraps 7}
-- Battery voltage control
mp800mkVbatChOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery voltage changing OK."
::= {mp800mkOkTraps 8}
-- Release device status
mp800mkRlsDevOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Release device is on."
::= {mp800mkOkTraps 9}
-- Battery cell voltage spread
mp800mkDVcellOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery cell voltage spread is in range."
::= {mp800mkOkTraps 10}
-- AC voltage
mp800mkACVOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"AC voltage is in range."
::= {mp800mkOkTraps 11}
-- Battery charge status
mp800mkBatChargeOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery charge status is OK."
::= {mp800mkOkTraps 12}
-- Load current
mp800mkIloadOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Load current is in range."
::= {mp800mkOkTraps 13}
-- Battery charge current
mp800mkIbatChOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery charge current is in range."
::= {mp800mkOkTraps 14}
-- Power supply status
mp800mkSuppOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Power supply from MPs."
::= {mp800mkOkTraps 15}
-- Battery disconnected?
mp800mkBatConnOkTrap NOTIFICATION-TYPE
OBJECTS {
mp800mkTrapParameter,
mp800mkTrapValue,
mp800mkTrapComment}
STATUS current
DESCRIPTION
"Battery is connected to MPs' output."
::= {mp800mkOkTraps 16}
-- mp800mk trap properties
mp800mkTrapTypes OBJECT IDENTIFIER ::= { eltrapGroup 10 }
mp800mkTrapParameter OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Parameter (V, I, T, etc...)"
::= { mp800mkTrapTypes 1 }
mp800mkTrapValue OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Value (X mV, Y mA, Z grad, etc...)"
::= { mp800mkTrapTypes 2 }
mp800mkTrapComment OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Comment (V is out of range [Vmin ... Vmax]!, etc...)"
::= { mp800mkTrapTypes 3 }
---------------------------------------------------------------------------------------------------------------------------
------------------------------------------- END MP800MK Traps -------------------------------------------------------------
---------------------------------------------------------------------------------------------------------------------------
eltrapNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
mc240StreamAlarmTrap,
mc240SyncAlarmTrap,
mc240ss7LinkAlarmTrap,
mc240ss7LinksetAlarmTrap,
mc240FileAlarmTrap,
mc240CardAlarmTrap,
mxlDPSAlarmTrap,
mxlTELEAlarmTrap,
mc240UPSAlarmTrap,
mc240SensAlarmTrap,
dslamLinkDownTrap,
dslamDSRateAlarmTrap,
dslamUSRateAlarmTrap,
ponONUAuthAlarmTrap,
ponEthAlarmTrap,
ponOpticalAlarmTrap,
mc240StreamOkTrap,
mc240SyncOkTrap,
mc240ss7LinkOkTrap,
mc240ss7LinksetOkTrap,
mc240FileOkTrap,
mc240CardOkTrap,
mxlDPSOkTrap,
mxlTELEOkTrap,
mc240UPSOkTrap,
mc240SensOkTrap,
dslamLinkUpTrap,
dslamDSRateOkTrap,
dslamUSRateOkTrap,
ponONUAuthOkTrap,
ponEthOkTrap,
ponOpticalOkTrap,
dslamOverheatAlarmTrap,
dslamVoltageAlarmTrap,
dslamSessionAlarmTrap,
dslamEthLinkAlarmTrap,
dslamOverheatOkTrap,
dslamVoltageOkTrap,
dslamSessionOkTrap,
dslamEthLinkOkTrap,
mp800mkMPStatusAlarmTrap,
mp800mkInpParmAlarmTrap,
mp800mkUEPConfAlarmTrap,
mp800mkTMAlarmTrap,
mp800mkACVMAlarmTrap,
mp800mkIbatMAlarmTrap,
mp800mkVbatMAlarmTrap,
mp800mkVbatChAlarmTrap,
mp800mkRlsDevAlarmTrap,
mp800mkDVcellAlarmTrap,
mp800mkACVAlarmTrap,
mp800mkBatChargeAlarmTrap,
mp800mkIloadAlarmTrap,
mp800mkIbatChAlarmTrap,
mp800mkSuppAlarmTrap,
mp800mkBatConnAlarmTrap,
mp800mkMPStatusOkTrap,
mp800mkInpParmOkTrap,
mp800mkUEPConfOkTrap,
mp800mkTMOkTrap,
mp800mkACVMOkTrap,
mp800mkIbatMOkTrap,
mp800mkVbatMOkTrap,
mp800mkVbatChOkTrap,
mp800mkRlsDevOkTrap,
mp800mkDVcellOkTrap,
mp800mkACVOkTrap,
mp800mkBatChargeOkTrap,
mp800mkIloadOkTrap,
mp800mkIbatChOkTrap,
mp800mkSuppOkTrap,
mp800mkBatConnOkTrap,
omsOperationCommandAlarm,
omsOperationCommandOk
}
STATUS current
DESCRIPTION
""
::= { eltrapGroup 100 }
eltrapObjectGroup OBJECT-GROUP
OBJECTS {
mcTrapExState,
mcTrapLParam1,
mcTrapLParam2,
mcTrapLParam3,
mcTrapID,
mcTrapDescr,
mcTrapRestoredAlarmID,
mcTrapSyncType,
mcReservedFlag }
STATUS current
DESCRIPTION
""
::= { eltrapGroup 101 }
END