-- -- Eltex Enterprise Specific MIB: Structure of Management Information -- -- Copyright (c) 2007-2009, Eltex Co -- -- The contents of this document are subject to change without notice. -- ELTEX-SMI DEFINITIONS ::= BEGIN IMPORTS enterprises, MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32 FROM SNMPv2-SMI DisplayString, TimeStamp FROM SNMPv2-TC OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF; eltex MODULE-IDENTITY LAST-UPDATED "200906031500Z" ORGANIZATION "Eltex Co" CONTACT-INFO "eltex@gcom.ru" DESCRIPTION "The Structure of Management Information for Eltex Networks." ::= { enterprises 34300 } -- -- Eltex MIB tree structure -- elHardware OBJECT-IDENTITY STATUS current DESCRIPTION "The root of eltex hardware OIDs." ::= { eltex 1 } elSoftware OBJECT-IDENTITY STATUS current DESCRIPTION "The root of eltex software OIDs." ::= { eltex 2 } eltrapGroup OBJECT-IDENTITY STATUS current DESCRIPTION "The root of eltex traps objects." ::= { eltex 3 } -- define trap groups -- mc240AlarmTraps OBJECT IDENTIFIER ::= { eltrapGroup 3 } -- define all traps ---- MC-240 traps -- mc240StreamAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 stream alarm trap. Severity: alert" ::= { mc240AlarmTraps 1 } mc240SyncAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 sync alarm trap. Severity: warning" ::= { mc240AlarmTraps 2 } mc240ss7LinkAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 ss7 link alarm trap. Severity: alert" ::= { mc240AlarmTraps 3 } mc240ss7LinksetAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 ss7 linkset alarm trap. Severity: critical" ::= { mc240AlarmTraps 4 } mc240FileAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 file alarm trap. Severity: critical" ::= { mc240AlarmTraps 5 } mc240CardAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 card alarm trap. Severity: critical" ::= { mc240AlarmTraps 6 } mxlDPSAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "mxl DSL DP system alarm trap" ::= { mc240AlarmTraps 7 } mxlTELEAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "mxl DSL DP system alarm trap" ::= { mc240AlarmTraps 8 } mc240UPSAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc240 UPS alarm trap" ::= { mc240AlarmTraps 9 } mc240SensAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc240 sensor alarm trap (mcTrapExState = sensors bit mask, param1=temp,C, param2=Hum,%)" ::= { mc240AlarmTraps 10 } -- ---- ---- ---- ---- ---- ---- MXA link alarm ---- ---- ---- ---- ---- ---- ---- -- dslamLinkDownTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "dslam link down trap (mcTrapExState = link state, param1 = ADSLport)" ::= { mc240AlarmTraps 11 } -- MXA change adsl port Downstream rate alarm -- dslamDSRateAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport)" ::= { mc240AlarmTraps 12 } -- MXA change adsl port Upstream rate alarm -- dslamUSRateAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport)" ::= { mc240AlarmTraps 13 } -- ---- ---- ---- ---- ---- ---- ---- GePON ALARMS ---- ---- ---- ---- ---- ---- ---- ---- -- GePON ONU Authorization Alarm -- ponONUAuthAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Bad registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU')" ::= { mc240AlarmTraps 14 } -- GePON Eth link Down -- ponEthAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Eth Link Down, mcTrapLParam1=Link Number, Description='GePON: Eth Link N down'" ::= { mc240AlarmTraps 15 } -- GePON Optical link Event -- ponOpticalAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "The optical link N (mcTrapLParam1) has no active devices" ::= { mc240AlarmTraps 16 } -- ---- ---- ---- ---- ---- ---- MXA ---- ---- ---- ---- ---- ---- ---- -- -- MXA overheat alarm -- dslamOverheatAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10)" ::= { mc240AlarmTraps 17 } -- MXA power alarm -- dslamVoltageAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "when voltage deviation become more 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value )" ::= { mc240AlarmTraps 18 } -- MXA session connect -- dslamSessionAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Trap sending when connection happen, mcTrapLParam1 - means connection from (0)-CLI (1)->Webs (2)->SNMP" ::= { mc240AlarmTraps 19 } -- MXA Eth OperStatus -- dslamEthLinkAlarmTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Trap sending when switch port link DOWN, mcTrapLParam1 - means port num: for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1; for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1" ::= { mc240AlarmTraps 20 } mc240OkTraps OBJECT IDENTIFIER ::= { eltrapGroup 4 } mc240StreamOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 stream ok trap. Severity: alert" ::= { mc240OkTraps 1 } mc240SyncOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 sync ok trap. Severity: warning" ::= { mc240OkTraps 2 } mc240ss7LinkOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 ss7 link ok trap. Severity: alert" ::= { mc240OkTraps 3 } mc240ss7LinksetOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 ss7 linkset ok trap. Severity: critical" ::= { mc240OkTraps 4 } mc240FileOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 file ok trap. Severity: critical" ::= { mc240OkTraps 5 } mc240CardOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc-240 card trap. Severity: critical" ::= { mc240OkTraps 6 } mxlDPSOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "mxl DSL DP system alarm trap (normal state)" ::= { mc240OkTraps 7 } mxlTELEOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "mxl DSL DP system alarm trap (normal state)" ::= { mc240OkTraps 8 } mc240UPSOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc240 UPS alarm trap (normal state)" ::= { mc240OkTraps 9 } mc240SensOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag} STATUS current DESCRIPTION "mc240 sensor alarm trap (normal state)" ::= { mc240OkTraps 10 } dslamLinkUpTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "dslam link up trap (mcTrapExState = link state == 0, param1 = ADSLport)" ::= { mc240OkTraps 11 } dslamDSRateOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport)" ::= { mc240OkTraps 12 } dslamUSRateOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport)" ::= { mc240OkTraps 13 } -- PON ok traps -- ponONUAuthOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Normal registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU')" ::= { mc240OkTraps 14 } ponEthOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Eth Link Up, mcTrapLParam1=Link Number, Description='GePON: Eth Link N up'" ::= { mc240OkTraps 15 } ponOpticalOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "The optical link N (mcTrapLParam1) has M (mcTrapLParam2) active devices" ::= { mc240OkTraps 16 } -- MXA dslamOverheatOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10)" ::= { mc240OkTraps 17 } dslamVoltageOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "when voltage deviation become less 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value )" ::= { mc240OkTraps 18 } -- MXA session connect -- dslamSessionOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Trap sending when connection closed, mcTrapLParam1 - means disconnection from (0)-CLI (1)->Webs (2)->SNMP" ::= { mc240OkTraps 19 } -- MXA Eth OperStatus -- dslamEthLinkOkTrap NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION "Trap sending when switch port link UP, mcTrapLParam1 - means port num: for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1; for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1" ::= { mc240OkTraps 20 } mc240TrapTypes OBJECT IDENTIFIER ::= { eltrapGroup 5 } -- trap properties mcTrapExState OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "state (additional state)" ::= { mc240TrapTypes 1 } mcTrapLParam1 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "param-1 (slot or index)" ::= { mc240TrapTypes 2 } mcTrapLParam2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "param-2 (port or index)" ::= { mc240TrapTypes 3 } mcTrapLParam3 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "param-3 (other index)" ::= { mc240TrapTypes 4 } mcTrapID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "ID (pbx trap id)" ::= { mc240TrapTypes 5 } mcTrapDescr OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "Alarm description" ::= { mc240TrapTypes 6 } mcTrapRestoredAlarmID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "If this restore event then here writed Alarm ID. If this alarm event then mcTrapRestoredAlarmID=0." ::= { mc240TrapTypes 7 } mcTrapSyncType OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Type of trap: 0 - Normal; 1 - Journal alarms; 2 - Active alarms" ::= { mc240TrapTypes 8 } mcReservedFlag OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Reserved flag" ::= { mc240TrapTypes 9 } -- OMS operation status traps -- omsOperationAlarmTraps OBJECT IDENTIFIER ::= { eltrapGroup 20 } omsOperationOkTraps OBJECT IDENTIFIER ::= { eltrapGroup 21 } omsOperationCommandAlarm NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION " mcTrapLParam1 = command ; mcTrapLParam2 = filetype mcTrapDescr = Description of operarion: DeviceName, command , tftp host, config filename, status=Error, cause of error" ::= { omsOperationAlarmTraps 1 } omsOperationCommandOk NOTIFICATION-TYPE OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr} STATUS current DESCRIPTION " mcTrapLParam1 = command ; mcTrapLParam2 = filetype mcTrapDescr = Description of operarion: DeviceName, command , tftp host, config filename, status=Ok" ::= { omsOperationOkTraps 1 } --------------------------------------------------------------------------------------------------------------------------- ----------------------------------------------- MP800MK Traps ------------------------------------------------------------- --------------------------------------------------------------------------------------------------------------------------- -- mp800mk ALARM traps mp800mkAlarmTraps OBJECT IDENTIFIER ::= { eltrapGroup 8 } -- MP status mp800mkMPStatusAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "MP operation error." ::= {mp800mkAlarmTraps 1} -- Input parameters mp800mkInpParmAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Incorrect input parameters." ::= {mp800mkAlarmTraps 2} -- UEP configuration mp800mkUEPConfAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "UEP configuration error." ::= {mp800mkAlarmTraps 3} -- Temperature measurement mp800mkTMAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Temperature measurement error." ::= {mp800mkAlarmTraps 4} -- AC voltage measurement mp800mkACVMAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "ACV measurement error." ::= {mp800mkAlarmTraps 5} -- Battery current measurement mp800mkIbatMAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery current measurement error." ::= {mp800mkAlarmTraps 6} -- Battery voltage measurement mp800mkVbatMAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery voltage measurement error." ::= {mp800mkAlarmTraps 7} -- Battery voltage control mp800mkVbatChAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Can't change (increase or decrease) battery voltage." ::= {mp800mkAlarmTraps 8} -- Release device status mp800mkRlsDevAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Release device is off (battery disconnected)." ::= {mp800mkAlarmTraps 9} -- Battery cell voltage spread mp800mkDVcellAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery cell voltage spread is out of range." ::= {mp800mkAlarmTraps 10} -- AC voltage mp800mkACVAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "AC voltage is out of range." ::= {mp800mkAlarmTraps 11} -- Battery charge status mp800mkBatChargeAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery is close to total discharge." ::= {mp800mkAlarmTraps 12} -- Load current mp800mkIloadAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Load current is out of range." ::= {mp800mkAlarmTraps 13} -- Battery charge current mp800mkIbatChAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery charge current is too high." ::= {mp800mkAlarmTraps 14} -- Power supply status mp800mkSuppAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Power supply from battery." ::= {mp800mkAlarmTraps 15} -- Battery disconnected? mp800mkBatConnAlarmTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery is disconnected from MPs' output." ::= {mp800mkAlarmTraps 16} -- mp800mk OK traps mp800mkOkTraps OBJECT IDENTIFIER ::= { eltrapGroup 9 } -- MP status mp800mkMPStatusOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "MP operation OK." ::= {mp800mkOkTraps 1} -- Input parameters mp800mkInpParmOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Input parameters OK." ::= {mp800mkOkTraps 2} -- UEP configuration mp800mkUEPConfOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "UEP configuration OK." ::= {mp800mkOkTraps 3} -- Temperature measurement mp800mkTMOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Temperature measurement OK." ::= {mp800mkOkTraps 4} -- AC voltage measurement mp800mkACVMOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "ACV measurement OK." ::= {mp800mkOkTraps 5} -- Battery current measurement mp800mkIbatMOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery current measurement OK." ::= {mp800mkOkTraps 6} -- Battery voltage measurement mp800mkVbatMOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery voltage measurement OK." ::= {mp800mkOkTraps 7} -- Battery voltage control mp800mkVbatChOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery voltage changing OK." ::= {mp800mkOkTraps 8} -- Release device status mp800mkRlsDevOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Release device is on." ::= {mp800mkOkTraps 9} -- Battery cell voltage spread mp800mkDVcellOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery cell voltage spread is in range." ::= {mp800mkOkTraps 10} -- AC voltage mp800mkACVOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "AC voltage is in range." ::= {mp800mkOkTraps 11} -- Battery charge status mp800mkBatChargeOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery charge status is OK." ::= {mp800mkOkTraps 12} -- Load current mp800mkIloadOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Load current is in range." ::= {mp800mkOkTraps 13} -- Battery charge current mp800mkIbatChOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery charge current is in range." ::= {mp800mkOkTraps 14} -- Power supply status mp800mkSuppOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Power supply from MPs." ::= {mp800mkOkTraps 15} -- Battery disconnected? mp800mkBatConnOkTrap NOTIFICATION-TYPE OBJECTS { mp800mkTrapParameter, mp800mkTrapValue, mp800mkTrapComment} STATUS current DESCRIPTION "Battery is connected to MPs' output." ::= {mp800mkOkTraps 16} -- mp800mk trap properties mp800mkTrapTypes OBJECT IDENTIFIER ::= { eltrapGroup 10 } mp800mkTrapParameter OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Parameter (V, I, T, etc...)" ::= { mp800mkTrapTypes 1 } mp800mkTrapValue OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Value (X mV, Y mA, Z grad, etc...)" ::= { mp800mkTrapTypes 2 } mp800mkTrapComment OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Comment (V is out of range [Vmin ... Vmax]!, etc...)" ::= { mp800mkTrapTypes 3 } --------------------------------------------------------------------------------------------------------------------------- ------------------------------------------- END MP800MK Traps ------------------------------------------------------------- --------------------------------------------------------------------------------------------------------------------------- eltrapNotificationGroup NOTIFICATION-GROUP NOTIFICATIONS { mc240StreamAlarmTrap, mc240SyncAlarmTrap, mc240ss7LinkAlarmTrap, mc240ss7LinksetAlarmTrap, mc240FileAlarmTrap, mc240CardAlarmTrap, mxlDPSAlarmTrap, mxlTELEAlarmTrap, mc240UPSAlarmTrap, mc240SensAlarmTrap, dslamLinkDownTrap, dslamDSRateAlarmTrap, dslamUSRateAlarmTrap, ponONUAuthAlarmTrap, ponEthAlarmTrap, ponOpticalAlarmTrap, mc240StreamOkTrap, mc240SyncOkTrap, mc240ss7LinkOkTrap, mc240ss7LinksetOkTrap, mc240FileOkTrap, mc240CardOkTrap, mxlDPSOkTrap, mxlTELEOkTrap, mc240UPSOkTrap, mc240SensOkTrap, dslamLinkUpTrap, dslamDSRateOkTrap, dslamUSRateOkTrap, ponONUAuthOkTrap, ponEthOkTrap, ponOpticalOkTrap, dslamOverheatAlarmTrap, dslamVoltageAlarmTrap, dslamSessionAlarmTrap, dslamEthLinkAlarmTrap, dslamOverheatOkTrap, dslamVoltageOkTrap, dslamSessionOkTrap, dslamEthLinkOkTrap, mp800mkMPStatusAlarmTrap, mp800mkInpParmAlarmTrap, mp800mkUEPConfAlarmTrap, mp800mkTMAlarmTrap, mp800mkACVMAlarmTrap, mp800mkIbatMAlarmTrap, mp800mkVbatMAlarmTrap, mp800mkVbatChAlarmTrap, mp800mkRlsDevAlarmTrap, mp800mkDVcellAlarmTrap, mp800mkACVAlarmTrap, mp800mkBatChargeAlarmTrap, mp800mkIloadAlarmTrap, mp800mkIbatChAlarmTrap, mp800mkSuppAlarmTrap, mp800mkBatConnAlarmTrap, mp800mkMPStatusOkTrap, mp800mkInpParmOkTrap, mp800mkUEPConfOkTrap, mp800mkTMOkTrap, mp800mkACVMOkTrap, mp800mkIbatMOkTrap, mp800mkVbatMOkTrap, mp800mkVbatChOkTrap, mp800mkRlsDevOkTrap, mp800mkDVcellOkTrap, mp800mkACVOkTrap, mp800mkBatChargeOkTrap, mp800mkIloadOkTrap, mp800mkIbatChOkTrap, mp800mkSuppOkTrap, mp800mkBatConnOkTrap, omsOperationCommandAlarm, omsOperationCommandOk } STATUS current DESCRIPTION "" ::= { eltrapGroup 100 } eltrapObjectGroup OBJECT-GROUP OBJECTS { mcTrapExState, mcTrapLParam1, mcTrapLParam2, mcTrapLParam3, mcTrapID, mcTrapDescr, mcTrapRestoredAlarmID, mcTrapSyncType, mcReservedFlag } STATUS current DESCRIPTION "" ::= { eltrapGroup 101 } END