ELTEX-MES-ISS-ENV-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32
|
|
FROM SNMPv2-SMI
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
eltMesIss
|
|
FROM ELTEX-MES-ISS-MIB
|
|
issSwitchFanEntry
|
|
FROM ARICENT-ISS-MIB
|
|
issSwitchFanIndex, issSwitchFanStatus
|
|
FROM ARICENT-ISS-MIB;
|
|
|
|
eltMesIssEnvMIB MODULE-IDENTITY
|
|
LAST-UPDATED "202106230000Z"
|
|
ORGANIZATION "Eltex Enterprise, Ltd."
|
|
CONTACT-INFO
|
|
"eltex-co.ru"
|
|
DESCRIPTION
|
|
"This private MIB module contains Eltex's hardware enviroment
|
|
definition."
|
|
REVISION "201904040000Z"
|
|
DESCRIPTION "Initial revision."
|
|
REVISION "202011250000Z"
|
|
DESCRIPTION "Added eltMesIssEnvDyingGasp, eltMesIssBatteryMonitorEnable objects."
|
|
REVISION "202104010000Z"
|
|
DESCRIPTION "Added eltMesIssEnvFan object."
|
|
REVISION "202106230000Z"
|
|
DESCRIPTION "Added eltMesIssEnvFanThresholdTable object."
|
|
::= { eltMesIss 12 }
|
|
|
|
-- Top level MIB structure
|
|
|
|
eltMesIssEnvObjects OBJECT IDENTIFIER ::= { eltMesIssEnvMIB 1 }
|
|
eltMesIssEnvNotifications OBJECT IDENTIFIER ::= { eltMesIssEnvMIB 2 }
|
|
|
|
-- MIB Groups
|
|
|
|
eltMesIssEnvDryContacts OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 1 }
|
|
eltMesIssEnvResetButton OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 2 }
|
|
eltMesIssEnvBattery OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 3 }
|
|
eltMesIssEnvDyingGasp OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 4 }
|
|
eltMesIssEnvFan OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 5 }
|
|
eltMesIssEnvPowerSource OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 6 }
|
|
|
|
eltMesIssEnvNotificationsPrefix OBJECT IDENTIFIER ::= { eltMesIssEnvNotifications 0 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- Textual Conversions
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
EltMesIssBatteryState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"States of the battery."
|
|
SYNTAX INTEGER {
|
|
notoperational(1),
|
|
notpresent(2),
|
|
recharge(3),
|
|
low(4),
|
|
discharge(5),
|
|
operational(6)
|
|
}
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- Dry Contacts global configuration
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
eltMesIssEnvDryContactsNotificationEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Disable or enable generation of eltMesIssEnvDryContactsTrap
|
|
notification upon changing state of any dry contacts."
|
|
DEFVAL { false }
|
|
::= { eltMesIssEnvDryContacts 1 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- Dry Contacts state table
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
eltMesIssEnvDryContactsStateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EltMesIssEnvDryContactsStateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about dry contacts state."
|
|
::= { eltMesIssEnvDryContacts 2 }
|
|
|
|
eltMesIssEnvDryContactsStateEntry OBJECT-TYPE
|
|
SYNTAX EltMesIssEnvDryContactsStateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in eltMesIssEnvDryContactsStateTable."
|
|
INDEX { eltMesIssEnvDryContactsGroup, eltMesIssEnvDryContactsIndex }
|
|
::= { eltMesIssEnvDryContactsStateTable 1 }
|
|
|
|
EltMesIssEnvDryContactsStateEntry ::= SEQUENCE {
|
|
eltMesIssEnvDryContactsGroup Integer32,
|
|
eltMesIssEnvDryContactsIndex Integer32,
|
|
eltMesIssEnvDryContactsState INTEGER
|
|
}
|
|
|
|
eltMesIssEnvDryContactsGroup OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the group containing the
|
|
dry contacts pair."
|
|
::= { eltMesIssEnvDryContactsStateEntry 1 }
|
|
|
|
eltMesIssEnvDryContactsIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the dry contacts pair within group
|
|
eltMesIssEnvDryContactsGroup."
|
|
::= { eltMesIssEnvDryContactsStateEntry 2 }
|
|
|
|
eltMesIssEnvDryContactsState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
opened(1),
|
|
closed(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable describes current state of dry contacts pair."
|
|
::= { eltMesIssEnvDryContactsStateEntry 3 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- Reset button global mode
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
eltEnvResetButtonMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(0),
|
|
disable(1),
|
|
reset-only(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mode of reset button: 0 - Enable, 1 - Disable, 2 - Reset-only mode"
|
|
DEFVAL { enable }
|
|
::= { eltMesIssEnvResetButton 1 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- External battery state table
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
eltMesIssBatteryStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EltMesIssBatteryStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table of battery status maintained by the environmental monitor
|
|
card."
|
|
::= { eltMesIssEnvBattery 1 }
|
|
|
|
eltMesIssBatteryStatusEntry OBJECT-TYPE
|
|
SYNTAX EltMesIssBatteryStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the battery status table, representing the status of
|
|
the associated battery maintained by the environmental monitor."
|
|
INDEX { eltMesIssBatteryStatusIndex }
|
|
::= { eltMesIssBatteryStatusTable 1 }
|
|
|
|
EltMesIssBatteryStatusEntry ::= SEQUENCE {
|
|
eltMesIssBatteryStatusIndex INTEGER,
|
|
eltMesIssBatteryStatus EltMesIssBatteryState,
|
|
eltMesIssBatteryLevel INTEGER
|
|
}
|
|
|
|
eltMesIssBatteryStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index for the battery being instrumented. This index is for SNMP
|
|
purposes only, and has no intrinsic meaning."
|
|
::= { eltMesIssBatteryStatusEntry 1 }
|
|
|
|
eltMesIssBatteryStatus OBJECT-TYPE
|
|
SYNTAX EltMesIssBatteryState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The mandatory state of the battery being instrumented."
|
|
::= { eltMesIssBatteryStatusEntry 2 }
|
|
|
|
eltMesIssBatteryLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100 | 255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remaining percentage of battery charge. Value of 255 means that this
|
|
parameter is undefined due to battery not supporting this feature or
|
|
because it cannot be obtained in current state."
|
|
::= { eltMesIssBatteryStatusEntry 3 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- External battery monitor
|
|
-- -----------------------------------------------------------------------------
|
|
eltMesIssBatteryMonitorEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the presence of a battery in the system
|
|
should be monitored or not."
|
|
DEFVAL { true }
|
|
::= { eltMesIssEnvBattery 2 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- Dying Gasp configuration
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
eltMesIssDyingGaspStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the dying gasp event handler is
|
|
enabled or disabled in the system."
|
|
DEFVAL { enable }
|
|
::= { eltMesIssEnvDyingGasp 1 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- Fan Table extension
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
eltMesIssEnvFanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EltMesIssEnvFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table augments the IssSwitchFanTable table."
|
|
::= { eltMesIssEnvFan 1 }
|
|
|
|
eltMesIssEnvFanEntry OBJECT-TYPE
|
|
SYNTAX EltMesIssEnvFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains information related to fan speed."
|
|
AUGMENTS { issSwitchFanEntry }
|
|
::= { eltMesIssEnvFanTable 1 }
|
|
|
|
EltMesIssEnvFanEntry ::= SEQUENCE {
|
|
eltMesIssEnvFanSpeed Integer32,
|
|
eltMesIssEnvFanSpeedLevel Integer32
|
|
}
|
|
|
|
eltMesIssEnvFanSpeed OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Numeric representation of the switch fan speed in RPM."
|
|
::= { eltMesIssEnvFanEntry 1 }
|
|
|
|
eltMesIssEnvFanSpeedLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (0..3)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the switch fan speed level (0 - lowest, 3 - highest)."
|
|
::= { eltMesIssEnvFanEntry 2 }
|
|
|
|
eltMesIssEnvFanThresholdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EltMesIssEnvFanThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the information about fan speed thresholds."
|
|
::= { eltMesIssEnvFan 2 }
|
|
|
|
eltMesIssEnvFanThresholdEntry OBJECT-TYPE
|
|
SYNTAX EltMesIssEnvFanThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains information related to fan speed thresholds."
|
|
INDEX { issSwitchFanIndex,
|
|
eltMesIssEnvFanThresholdLevel }
|
|
::= { eltMesIssEnvFanThresholdTable 1 }
|
|
|
|
EltMesIssEnvFanThresholdEntry ::= SEQUENCE {
|
|
eltMesIssEnvFanThresholdLevel Integer32,
|
|
eltMesIssEnvFanThresholdMin Integer32,
|
|
eltMesIssEnvFanThresholdMax Integer32
|
|
}
|
|
|
|
eltMesIssEnvFanThresholdLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the fan speed level"
|
|
::= { eltMesIssEnvFanThresholdEntry 1 }
|
|
|
|
eltMesIssEnvFanThresholdMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low fan speed threshold in RPM."
|
|
::= { eltMesIssEnvFanThresholdEntry 2 }
|
|
|
|
eltMesIssEnvFanThresholdMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High fan speed threshold in RPM."
|
|
::= { eltMesIssEnvFanThresholdEntry 3 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- Power source table
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
eltMesIssEnvPowerSourceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EltMesIssEnvPowerSourceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about power sources state."
|
|
::= { eltMesIssEnvPowerSource 1 }
|
|
|
|
eltMesIssEnvPowerSourceEntry OBJECT-TYPE
|
|
SYNTAX EltMesIssEnvPowerSourceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in eltMesIssEnvPowerSourceStateTable."
|
|
INDEX { eltMesIssEnvPowerSourceIndex }
|
|
::= { eltMesIssEnvPowerSourceTable 1 }
|
|
|
|
EltMesIssEnvPowerSourceEntry ::= SEQUENCE {
|
|
eltMesIssEnvPowerSourceIndex Integer32,
|
|
eltMesIssEnvPowerSourceType INTEGER,
|
|
eltMesIssEnvPowerSourceState INTEGER
|
|
}
|
|
|
|
eltMesIssEnvPowerSourceIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the power source number."
|
|
::= { eltMesIssEnvPowerSourceEntry 1 }
|
|
|
|
eltMesIssEnvPowerSourceType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
main(1),
|
|
redundant(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable describes current type of power source."
|
|
::= { eltMesIssEnvPowerSourceEntry 2 }
|
|
|
|
eltMesIssEnvPowerSourceState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
operational(1),
|
|
not-operational(2),
|
|
not-present(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable describes current state of power source."
|
|
::= { eltMesIssEnvPowerSourceEntry 3 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- Notifications
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
eltMesIssEnvDryContactsTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eltMesIssEnvDryContactsGroup,
|
|
eltMesIssEnvDryContactsIndex,
|
|
eltMesIssEnvDryContactsState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A eltMesIssEnvDryContactsTrap is generated upon dry contacts status
|
|
change."
|
|
::= { eltMesIssEnvNotificationsPrefix 1 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- External battery trap notify
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
eltMesIssBatteryTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
eltMesIssBatteryStatus,
|
|
eltMesIssBatteryLevel
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Battery status notification trap message."
|
|
::= { eltMesIssEnvNotificationsPrefix 2 }
|
|
|
|
-- -----------------------------------------------------------------------------
|
|
-- Fan status trap notify
|
|
-- -----------------------------------------------------------------------------
|
|
|
|
eltMesIssEnvFanStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
issSwitchFanIndex,
|
|
issSwitchFanStatus,
|
|
eltMesIssEnvFanSpeed,
|
|
eltMesIssEnvFanSpeedLevel
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan status notification trap message."
|
|
::= { eltMesIssEnvNotificationsPrefix 3 }
|
|
|
|
END
|