ELTEX-MES-ISS-ENV-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32 FROM SNMPv2-SMI TruthValue FROM SNMPv2-TC eltMesIss FROM ELTEX-MES-ISS-MIB issSwitchFanEntry FROM ARICENT-ISS-MIB issSwitchFanIndex, issSwitchFanStatus FROM ARICENT-ISS-MIB; eltMesIssEnvMIB MODULE-IDENTITY LAST-UPDATED "202106230000Z" ORGANIZATION "Eltex Enterprise, Ltd." CONTACT-INFO "eltex-co.ru" DESCRIPTION "This private MIB module contains Eltex's hardware enviroment definition." REVISION "201904040000Z" DESCRIPTION "Initial revision." REVISION "202011250000Z" DESCRIPTION "Added eltMesIssEnvDyingGasp, eltMesIssBatteryMonitorEnable objects." REVISION "202104010000Z" DESCRIPTION "Added eltMesIssEnvFan object." REVISION "202106230000Z" DESCRIPTION "Added eltMesIssEnvFanThresholdTable object." ::= { eltMesIss 12 } -- Top level MIB structure eltMesIssEnvObjects OBJECT IDENTIFIER ::= { eltMesIssEnvMIB 1 } eltMesIssEnvNotifications OBJECT IDENTIFIER ::= { eltMesIssEnvMIB 2 } -- MIB Groups eltMesIssEnvDryContacts OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 1 } eltMesIssEnvResetButton OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 2 } eltMesIssEnvBattery OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 3 } eltMesIssEnvDyingGasp OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 4 } eltMesIssEnvFan OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 5 } eltMesIssEnvPowerSource OBJECT IDENTIFIER ::= { eltMesIssEnvObjects 6 } eltMesIssEnvNotificationsPrefix OBJECT IDENTIFIER ::= { eltMesIssEnvNotifications 0 } -- ----------------------------------------------------------------------------- -- Textual Conversions -- ----------------------------------------------------------------------------- EltMesIssBatteryState ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "States of the battery." SYNTAX INTEGER { notoperational(1), notpresent(2), recharge(3), low(4), discharge(5), operational(6) } -- ----------------------------------------------------------------------------- -- Dry Contacts global configuration -- ----------------------------------------------------------------------------- eltMesIssEnvDryContactsNotificationEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Disable or enable generation of eltMesIssEnvDryContactsTrap notification upon changing state of any dry contacts." DEFVAL { false } ::= { eltMesIssEnvDryContacts 1 } -- ----------------------------------------------------------------------------- -- Dry Contacts state table -- ----------------------------------------------------------------------------- eltMesIssEnvDryContactsStateTable OBJECT-TYPE SYNTAX SEQUENCE OF EltMesIssEnvDryContactsStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about dry contacts state." ::= { eltMesIssEnvDryContacts 2 } eltMesIssEnvDryContactsStateEntry OBJECT-TYPE SYNTAX EltMesIssEnvDryContactsStateEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in eltMesIssEnvDryContactsStateTable." INDEX { eltMesIssEnvDryContactsGroup, eltMesIssEnvDryContactsIndex } ::= { eltMesIssEnvDryContactsStateTable 1 } EltMesIssEnvDryContactsStateEntry ::= SEQUENCE { eltMesIssEnvDryContactsGroup Integer32, eltMesIssEnvDryContactsIndex Integer32, eltMesIssEnvDryContactsState INTEGER } eltMesIssEnvDryContactsGroup OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the group containing the dry contacts pair." ::= { eltMesIssEnvDryContactsStateEntry 1 } eltMesIssEnvDryContactsIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the dry contacts pair within group eltMesIssEnvDryContactsGroup." ::= { eltMesIssEnvDryContactsStateEntry 2 } eltMesIssEnvDryContactsState OBJECT-TYPE SYNTAX INTEGER { opened(1), closed(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable describes current state of dry contacts pair." ::= { eltMesIssEnvDryContactsStateEntry 3 } -- ----------------------------------------------------------------------------- -- Reset button global mode -- ----------------------------------------------------------------------------- eltEnvResetButtonMode OBJECT-TYPE SYNTAX INTEGER { enable(0), disable(1), reset-only(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Mode of reset button: 0 - Enable, 1 - Disable, 2 - Reset-only mode" DEFVAL { enable } ::= { eltMesIssEnvResetButton 1 } -- ----------------------------------------------------------------------------- -- External battery state table -- ----------------------------------------------------------------------------- eltMesIssBatteryStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF EltMesIssBatteryStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table of battery status maintained by the environmental monitor card." ::= { eltMesIssEnvBattery 1 } eltMesIssBatteryStatusEntry OBJECT-TYPE SYNTAX EltMesIssBatteryStatusEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the battery status table, representing the status of the associated battery maintained by the environmental monitor." INDEX { eltMesIssBatteryStatusIndex } ::= { eltMesIssBatteryStatusTable 1 } EltMesIssBatteryStatusEntry ::= SEQUENCE { eltMesIssBatteryStatusIndex INTEGER, eltMesIssBatteryStatus EltMesIssBatteryState, eltMesIssBatteryLevel INTEGER } eltMesIssBatteryStatusIndex OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unique index for the battery being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning." ::= { eltMesIssBatteryStatusEntry 1 } eltMesIssBatteryStatus OBJECT-TYPE SYNTAX EltMesIssBatteryState MAX-ACCESS read-only STATUS current DESCRIPTION "The mandatory state of the battery being instrumented." ::= { eltMesIssBatteryStatusEntry 2 } eltMesIssBatteryLevel OBJECT-TYPE SYNTAX INTEGER (0..100 | 255) MAX-ACCESS read-only STATUS current DESCRIPTION "Remaining percentage of battery charge. Value of 255 means that this parameter is undefined due to battery not supporting this feature or because it cannot be obtained in current state." ::= { eltMesIssBatteryStatusEntry 3 } -- ----------------------------------------------------------------------------- -- External battery monitor -- ----------------------------------------------------------------------------- eltMesIssBatteryMonitorEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the presence of a battery in the system should be monitored or not." DEFVAL { true } ::= { eltMesIssEnvBattery 2 } -- ----------------------------------------------------------------------------- -- Dying Gasp configuration -- ----------------------------------------------------------------------------- eltMesIssDyingGaspStatus OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates whether the dying gasp event handler is enabled or disabled in the system." DEFVAL { enable } ::= { eltMesIssEnvDyingGasp 1 } -- ----------------------------------------------------------------------------- -- Fan Table extension -- ----------------------------------------------------------------------------- eltMesIssEnvFanTable OBJECT-TYPE SYNTAX SEQUENCE OF EltMesIssEnvFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table augments the IssSwitchFanTable table." ::= { eltMesIssEnvFan 1 } eltMesIssEnvFanEntry OBJECT-TYPE SYNTAX EltMesIssEnvFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Contains information related to fan speed." AUGMENTS { issSwitchFanEntry } ::= { eltMesIssEnvFanTable 1 } EltMesIssEnvFanEntry ::= SEQUENCE { eltMesIssEnvFanSpeed Integer32, eltMesIssEnvFanSpeedLevel Integer32 } eltMesIssEnvFanSpeed OBJECT-TYPE SYNTAX Integer32 (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Numeric representation of the switch fan speed in RPM." ::= { eltMesIssEnvFanEntry 1 } eltMesIssEnvFanSpeedLevel OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the switch fan speed level (0 - lowest, 3 - highest)." ::= { eltMesIssEnvFanEntry 2 } eltMesIssEnvFanThresholdTable OBJECT-TYPE SYNTAX SEQUENCE OF EltMesIssEnvFanThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the information about fan speed thresholds." ::= { eltMesIssEnvFan 2 } eltMesIssEnvFanThresholdEntry OBJECT-TYPE SYNTAX EltMesIssEnvFanThresholdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Contains information related to fan speed thresholds." INDEX { issSwitchFanIndex, eltMesIssEnvFanThresholdLevel } ::= { eltMesIssEnvFanThresholdTable 1 } EltMesIssEnvFanThresholdEntry ::= SEQUENCE { eltMesIssEnvFanThresholdLevel Integer32, eltMesIssEnvFanThresholdMin Integer32, eltMesIssEnvFanThresholdMax Integer32 } eltMesIssEnvFanThresholdLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Indicates the fan speed level" ::= { eltMesIssEnvFanThresholdEntry 1 } eltMesIssEnvFanThresholdMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Low fan speed threshold in RPM." ::= { eltMesIssEnvFanThresholdEntry 2 } eltMesIssEnvFanThresholdMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "High fan speed threshold in RPM." ::= { eltMesIssEnvFanThresholdEntry 3 } -- ----------------------------------------------------------------------------- -- Power source table -- ----------------------------------------------------------------------------- eltMesIssEnvPowerSourceTable OBJECT-TYPE SYNTAX SEQUENCE OF EltMesIssEnvPowerSourceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about power sources state." ::= { eltMesIssEnvPowerSource 1 } eltMesIssEnvPowerSourceEntry OBJECT-TYPE SYNTAX EltMesIssEnvPowerSourceEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in eltMesIssEnvPowerSourceStateTable." INDEX { eltMesIssEnvPowerSourceIndex } ::= { eltMesIssEnvPowerSourceTable 1 } EltMesIssEnvPowerSourceEntry ::= SEQUENCE { eltMesIssEnvPowerSourceIndex Integer32, eltMesIssEnvPowerSourceType INTEGER, eltMesIssEnvPowerSourceState INTEGER } eltMesIssEnvPowerSourceIndex OBJECT-TYPE SYNTAX Integer32 (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "This variable uniquely identifies the power source number." ::= { eltMesIssEnvPowerSourceEntry 1 } eltMesIssEnvPowerSourceType OBJECT-TYPE SYNTAX INTEGER { main(1), redundant(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable describes current type of power source." ::= { eltMesIssEnvPowerSourceEntry 2 } eltMesIssEnvPowerSourceState OBJECT-TYPE SYNTAX INTEGER { operational(1), not-operational(2), not-present(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "This variable describes current state of power source." ::= { eltMesIssEnvPowerSourceEntry 3 } -- ----------------------------------------------------------------------------- -- Notifications -- ----------------------------------------------------------------------------- eltMesIssEnvDryContactsTrap NOTIFICATION-TYPE OBJECTS { eltMesIssEnvDryContactsGroup, eltMesIssEnvDryContactsIndex, eltMesIssEnvDryContactsState } STATUS current DESCRIPTION "A eltMesIssEnvDryContactsTrap is generated upon dry contacts status change." ::= { eltMesIssEnvNotificationsPrefix 1 } -- ----------------------------------------------------------------------------- -- External battery trap notify -- ----------------------------------------------------------------------------- eltMesIssBatteryTrap NOTIFICATION-TYPE OBJECTS { eltMesIssBatteryStatus, eltMesIssBatteryLevel } STATUS current DESCRIPTION "Battery status notification trap message." ::= { eltMesIssEnvNotificationsPrefix 2 } -- ----------------------------------------------------------------------------- -- Fan status trap notify -- ----------------------------------------------------------------------------- eltMesIssEnvFanStatusTrap NOTIFICATION-TYPE OBJECTS { issSwitchFanIndex, issSwitchFanStatus, eltMesIssEnvFanSpeed, eltMesIssEnvFanSpeedLevel } STATUS current DESCRIPTION "Fan status notification trap message." ::= { eltMesIssEnvNotificationsPrefix 3 } END