Observium_CE/mibs/electroline/ELECTROLINE-DHT-CONFIG-MIB

814 lines
31 KiB
Plaintext

--*****************************************************************************
--
-- Copyright 2013 Electroline Equipment Inc
-- All Rights Reserved
--
--
--
--*****************************************************************************
-- Filename: ELECTROLINE-DHT-CONFIG.mib
-- Author: Eric Alarie
-- Creation Date: 2003.03.20
--*****************************************************************************
-- Description:
--
-- This file contains the SNMPv2 MIB definition of the Configuration branch
-- for the DHT products.
--
--*****************************************************************************
-- Revision History:
-- 2003.03.20 Eric Alarie First Draft
-- 2003.03.21 Carlene Gardner Linguistic revision
-- 2003.05.13 Eric Alarie Updated for release 1.0.x of the DHT
-- 2003.05.21 Carlene Gardner Linguistic revision
-- 2003.05.27 Eric Alarie Added Battery save on/off and some
-- storage for the EMS.
-- 2003.07.07 Carlene Gardner Linguistic revision
-- 2004.01.26 Carlene Gardner Added cfgHmsEmsAlarmTrapAssurance
-- 2004.07.1 Nath Mercure Added cfgPsNominalInputVoltage Mib (120V or 240V)
-- 2004.07.14 Eric Alarie Added SnmpTimeout MIB
-- 2004.10.01 Eric Alarie Changed the default value comment for
-- cfgEmsTimeout and cfgSnmpTimeout.
-- 2004.12.17 Eric Alarie Added ps temperature calibration MIB for NA01
-- 2005.06.20 Eric Alarie Added cfgDhtSnmpAgent MIB branch
-- 2005.06.22 Eric Alarie Added Dual IP MIBs
-- 2006.02.07 Alain Leclerc changed displayString for octetstring size (0..127)
-- 2006.02.07 Alain Leclerc autostoptimer must not support a value of 0
-- 2006.03.20 Louis Roy Added cfgOutputCurrent & modified cfgBatterySaveEnable
-- 2006.04.25 Eric Alarie cfgEmsCompatibilityMode is obsolete
-- 2006.08.15 Eric Alarie Added the configuration of the trap port number
-- 2007.02.21 Louis Roy Added the configuration for the battery Lithium-Ion
-- 2007.03.02 Louis Roy Added the configuration for the battery type
-- 2007.03.22 Louis Roy Commented the add for the battery type and Lithium-Ion
-- 2009.01.08 Alain Leclerc Added support for manual setting in usmUnifed Power supply
-- 2011.10.13 Louis Roy Added support to manually allow the creation of the Generic Analog Power supply
-- 2012.03.27 Paul Zheng Added IMPORTS from RFC 4001, the TEXTUAL-CONVENTION for InetAddress and InetAddressType;
-- added 2 objects cfgHmsEmsAddressTypeInet, cfgHmsEmsAddressInet to support IPv6 address;
-- deprecate cfgHmsEmsAddressIP;
-- 2012.03.27 Louis Roy Added a MIB to allow the user to select the source of measurement perform by the DHT
-- between the communication port or the analog port (cfgPsMeasurementSource)
-- 2012.06.18 Louis Roy Added a table that allow the provisionning of the Dual IP HMS SNMP access through IP filter
-- 2013.06.12 Eric Lariviere Added a MIB to allow commonVendorInfo override.
-- 2013.07.24 Eric Lariviere Added a MIB to control how HMS Mibs represent time.
-- 2014-01-14 Alain Leclerc Some mibs are depricated
--
--*****************************************************************************
ELECTROLINE-DHT-CONFIG-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32
FROM SNMPv2-SMI
RowStatus, TruthValue
FROM SNMPv2-TC
dhtConfiguration
FROM ELECTROLINE-DHT-ROOT-MIB
DisplayString
FROM RFC1213-MIB
NetworkAddress
FROM RFC1155-SMI
InetAddress,
InetAddressType
FROM INET-ADDRESS-MIB; -- RFC 4001
-- ****************************************************************************
-- * Definition of Configuration Sub-groups
-- ****************************************************************************
dhtCfgGlobal OBJECT-IDENTITY
STATUS current
DESCRIPTION "Group of configuration objects related to all DHT models"
::= { dhtConfiguration 1 }
dhtCfgPowerSupply OBJECT-IDENTITY
STATUS current
DESCRIPTION "Group of configuration objects related to the DHT-PS-NA-01 model only"
::= { dhtConfiguration 2 }
-- ****************************************************************************
-- * EMS CONFIGURATION DATA
-- *
-- * The following MIB objects control communication (Traps) with external Element
-- * / Network Management Systems. It includes the EMS Address Table that is used to
-- * indicate to the DHT the IP addresses of the EMS / NMS and related parameters.
-- * The HmsCold / Warm start trap assurance mechanism is an Electroline enhancement
-- * that is required for the EEMS. See ELECTROLINE-DHT-STATUS.mib for further
-- * details.
-- ****************************************************************************
dhtCfgHmsEms OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This sub-tree contains configuration information for trap management."
::= { dhtCfgGlobal 1 }
cfgHmsEmsAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfgHmsEmsAddressEntry
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the list of network addresses of the Element Management System(s)
to which the DHT will send its HmsColdStart, HmsWarmStart and HmsAlarmEvent traps.
The entries in this table are stored in non-volatile memory.
A maximum of 10 entries is supported.
"
::= { dhtCfgHmsEms 1 }
cfgHmsEmsAddressEntry OBJECT-TYPE
SYNTAX CfgHmsEmsAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"HMS EMS entry definition"
INDEX { cfgHmsEmsAddressIndex }
::= { cfgHmsEmsAddressTable 1 }
CfgHmsEmsAddressEntry ::=
SEQUENCE
{
cfgHmsEmsAddressIndex INTEGER,
cfgHmsEmsAddressIP IpAddress,
cfgHmsEmsAddressStartTrapAssurance TruthValue,
cfgHmsEmsAddressAlarmTrapAssurance TruthValue,
cfgHmsEmsAddressTrapPortNumber INTEGER,
cfgHmsEmsAddressTypeInet InetAddressType,
cfgHmsEmsAddressInet InetAddress,
}
cfgHmsEmsAddressIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the EMS address table"
::= { cfgHmsEmsAddressEntry 1 }
cfgHmsEmsAddressIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"IPv4 address of the destination EMS that will receive HMS traps.
If the EMS server address is unknown or is not an IPv4 address, return 0.0.0.0..
Valide IPv4 address set will update also cfgHmsEmsAddressInet and cfgHmsEmsAddressTypeInet.
This object is deprecated and is replaced by cfgHmsEmsAddressInet."
::= { cfgHmsEmsAddressEntry 2 }
cfgHmsEmsAddressStartTrapAssurance OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this MIB is set to one, additional binding is appended to
the cold or warm start Trap (HMS). The EMS must set the bound OID
to 1 to acknowledge receipt of the trap. The DHT then uses the
cfgEmsTimeout & cfgEmsRetry to resend the trap if necessary."
::= { cfgHmsEmsAddressEntry 3 }
cfgHmsEmsAddressAlarmTrapAssurance OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When this MIB is set to true, additional binding is appended to all
the Alarm Traps (HMS). The EMS must set the bound OID
to x to acknowledge receipt of the trap (where x is the total number of traps received).
The DHT then uses the cfgEmsTimeout & cfgEmsRetry to send an AlarmAssurance trap
if necessary."
::= { cfgHmsEmsAddressEntry 4 }
cfgHmsEmsAddressTrapPortNumber OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This represents the Ems's port number to which the trap will be sent to.
The default value is the common SNMP trap port (162)."
::= { cfgHmsEmsAddressEntry 5 }
cfgHmsEmsAddressTypeInet OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address type of the EMS server.
Values: unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), dns(16)
The update of this object is coherent to cfgHmsEmsAddressIP object."
::= { cfgHmsEmsAddressEntry 6 }
cfgHmsEmsAddressInet OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IPv4 or IPv6 address of the destination EMS that will receive traps.
If the message server is unknown, return the zero-length address string.
The update of this object is coherent to cfgHmsEmsAddressIP object."
::= { cfgHmsEmsAddressEntry 7}
cfgEmsTimeout OBJECT-TYPE
SYNTAX INTEGER (1..86400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the period of time (in seconds) during which the DHT expects to receive
an acknowlege trap from an EMS that has enabled trap assurance. If no acknowledge message
is received after the period has elapsed, the DHT then resends the trap. This process is
repeated until either the command is successful or the number of retries defined in cfgEmsRetry
has been reached.
The same timeout value is used for all destination EMS entries.
The default value for this MIB is 300 seconds
The value of this MIB is stored in non-volatile memory.
"
::= { dhtCfgHmsEms 2 }
cfgEmsRetry OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the number of times that the DHT resends a trap to an EMS that has
enabled the trap assurance, if no acknowledge message is received.
The default value is zero, meaning that the traps are never resent; a value
of -1 means that there is no limit on the number of retries.
The same retry count value is used for all EMS entries.
The value of this MIB is stored in non-volatile memory.
"
::= { dhtCfgHmsEms 3 }
cfgEmsDefaultHmsProperties OBJECT-TYPE
SYNTAX INTEGER {setToDefault(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB can be used to reset all HMS properties (both analog and
discrete table entries) to their factory default values."
::= { dhtCfgHmsEms 4 }
cfgEmsCompatibilityMode OBJECT-TYPE
SYNTAX INTEGER {hmsMode(0), dhtMode(1)}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"This MIB is not currently supported by the DHT "
::= { dhtCfgHmsEms 5 }
cfgEmsXpdrName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB is used by the EEMS software. Its value has no impact on the DHT's
operation, but is stored in its non-volatile memory"
::= { dhtCfgHmsEms 6 }
cfgEmsXpdrLocation OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB is used by the EEMS software. Its value has no impact on the DHT's
operation, but is stored in its non-volatile memory"
::= { dhtCfgHmsEms 7 }
cfgEmsXpdrDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB is used by the EEMS software. Its value has no impact on the DHT's
operation, but is stored in its non-volatile memory"
::= { dhtCfgHmsEms 8 }
cfgEmsXpdrGroupPath OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB is used by the EEMS software to indicate the logical group to
which this DHT belongs. This value has no impact on the DHT's operation, but is stored in
its non-volatile memory"
::= { dhtCfgHmsEms 9 }
cfgEmsXpdrCustomField1 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB is used by the EEMS software to store user-defined data on
this DHT. This value has no impact on the DHT's operation, but is stored in
its non-volatile memory"
::= { dhtCfgHmsEms 10 }
cfgEmsXpdrCustomField2 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB is used by the EEMS software to store user-defined data on
this DHT. This value has no impact on the DHT's operation, but is stored in
its non-volatile memory"
::= { dhtCfgHmsEms 11 }
cfgEmsXpdrCustomField3 OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB is used by the EEMS software to store user-defined data on
this DHT. This value has no impact on the DHT's operation, but is stored in
its non-volatile memory"
::= { dhtCfgHmsEms 12 }
-- ****************************************************************************
-- * GLOBAL CONFIGURATION DATA
-- *
-- * These MIB objects control some functions of the DHT that cannot be set
-- * through HMS or DOCSIS MIBs.
-- ****************************************************************************
dhtCfgResetToFactory OBJECT-TYPE
SYNTAX INTEGER {reset(1)}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This MIB can be used to remotely restore the factory default values, thus overwriting
any other setup values (HMS and internal transponder settings) that were stored
in the DHT's non-volatile memory. The transponder must be reset following this
command (commonReset or other reset function).
Deprecated. Has been move into electrolineCommon branch."
::= { dhtCfgGlobal 2 }
dhtCfgUsbMode OBJECT-TYPE
SYNTAX INTEGER {disable(0), cpe(1), craft(2)}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This MIB controls the behavior of the USB port. In craft mode, the USB port
has a default MAC address which enables a PC to be connected locally to
any DHT with the same driver and network adapter settings.
In craft mode, read access to the DOCSIS MIBS and read/write access to the HMS is allowed.
In CPE mode, the USB port behaves like a normal cable modem USB port,
allowing access to the network if this access has been provisioned by the CMTS.
In CPE mode, access to the MIBs is as per DOCSIS specifications. As well, read-write
access to the Electroline MIBs is permitted.
The transponder must be reset following this command (commonReset or other
reset function) in order for the change to take effect.
The value of this MIB is stored in non-volatile memory.
Deprecated. Has been move into electrolineCommon branch.
See cfgLocalInterfaceMode"
::= { dhtCfgGlobal 3 }
-- ****************************************************************************
-- * TIMING RELATED CONFIGURATION DATA
-- *
-- * This branch of the Electroline MIB allows configuration of certain timings
-- * in the DHT's operation
-- ****************************************************************************
dhtCfgTimers OBJECT-IDENTITY
STATUS deprecated
DESCRIPTION "Group of configuration objects related to DHT timing.
Deprecated. Has been move into electrolineCommon branch"
::= { dhtCfgGlobal 4 }
cfgSnmpTimeout OBJECT-TYPE
SYNTAX INTEGER (0..10080)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This MIB controls the SNMP activity watchdog period. The value is in minutes.
A value of zero deactivates the feature. When the feature is active, if the DHT
does NOT receive any SNMP packets during the period, the DHT will reset.
The value of this MIB is stored in non-volatile memory. Default value is 0 (off).
Deprecated. Has been move into electrolineCommon branch."
::= { dhtCfgTimers 1 }
-- ****************************************************************************
-- * Dual IP RELATED CONFIGURATION
-- *
-- * This branch of the Electroline MIB should be used to control the IP behavior
-- * of the DHT, it controls if the monitoring part of the DHT will be accessible
-- * from the DOCSIS SNMP agent or through a separate SNMP agent.
-- ****************************************************************************
dhtCfgIpInterfaces OBJECT-IDENTITY
STATUS deprecated
DESCRIPTION
"This sections specifies IP behavior for the DHT monitoring interface.
This section has been move to the electroline Common branch"
::= { dhtCfgGlobal 5 }
cfgDhtIpMode OBJECT-TYPE
SYNTAX INTEGER {singleIp(1), dualIp(2)}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object controls the IP interface behavior of the DHT
Set it to singleIp(1) to access HMS MIB objects through the DOCSIS management interface.
Set it to dualIp(2) to instruct the DHT to manage a virtual CPE with a separate IP address
and a separate SNMP agent to access the HMS MIBs.
The default value for this MIB is singleIp(1).
A transponder reset after setting this MIB is necessary in order for the change to take effect.
The value of this MIB is stored in non-volatile memory.
Deprecated. Has been move into electrolineCommon branch."
::= { dhtCfgIpInterfaces 1 }
cfgHmsSnmpAgent OBJECT-IDENTITY
STATUS deprecated
DESCRIPTION
"This sections specifies controls for the agents.
This section has been move to electrolineCommon branch"
::= { dhtCfgIpInterfaces 50 }
hmsSnmpManagerCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This MIB is used to specify the SNMP community string
used for write access to the SNMP agent in Dual IP mode.
The default value for this MIB is DhtHmsWriteSecret.
The value of this MIB is stored in non-volatile memory.
Deprecated. Has been move into electrolineCommon branch."
::= { cfgHmsSnmpAgent 1 }
hmsSnmpMonitorCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This MIB is used to specify the SNMP Read-only community string
used to access the SNMP agent in Dual IP mode.
The default value for this MIB is DhtHmsReadSecret.
The value of this MIB is stored in non-volatile memory.
Deprecated. Has been move into electrolineCommon branch."
::= { cfgHmsSnmpAgent 2 }
cfgHmsSnmpAccess OBJECT-IDENTITY
STATUS deprecated
DESCRIPTION
"This sub-tree contains configuration information for HMS SNMP access management.
Deprecated. Has been move into electrolineCommon branch."
::= { cfgHmsSnmpAgent 3 }
cfgHmsSnmpAccessTable OBJECT-TYPE
SYNTAX SEQUENCE OF CfgHmsSnmpAccessEntry
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This table allow access to SNMP objects by network management stations. If the table
is empty, access to SNMP objects is unrestricted.
Deprecated. Has been move into electrolineCommon branch."
::= { cfgHmsSnmpAccess 1 }
cfgHmsSnmpAccessEntry OBJECT-TYPE
SYNTAX CfgHmsSnmpAccessEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"HMS SNMP Access entry definition
Deprecated. Has been move into electrolineCommon branch."
INDEX { cfgHmsSnmpAccessIndex }
::= { cfgHmsSnmpAccessTable 1 }
CfgHmsSnmpAccessEntry ::=
SEQUENCE
{
cfgHmsSnmpAccessIndex INTEGER,
cfgHmsSnmpAccessIP IpAddress,
cfgHmsSnmpAccessIPMask IpAddress,
}
cfgHmsSnmpAccessIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Index into the HMS SNMP access table.
Deprecated. Has been move into electrolineCommon branch."
::= { cfgHmsSnmpAccessEntry 1 }
cfgHmsSnmpAccessIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"IPv4 address of the network management station.
Deprecated. Has been move into electrolineCommon branch."
::= { cfgHmsSnmpAccessEntry 2 }
cfgHmsSnmpAccessIPMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"IPv4 subnet mask of the network management station"
::= { cfgHmsSnmpAccessEntry 3 }
-- ****************************************************************************
-- * GLOBAL CONFIGURATION DATA
-- *
-- * These MIB objects control some functions of the DHT that cannot be set
-- * through HMS or DOCSIS MIBs.
-- ****************************************************************************
dhtCfgVendorInfo OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Vendor-specific information in human-readable format. When set, it mirrors and
overrides the mib commonVendorInfo from the SCTE tree.
Deprecated. Has been move into electrolineCommon branch."
::= { dhtCfgGlobal 6 }
dhtCfgHmsTimeReference OBJECT-TYPE
SYNTAX INTEGER {local(1), utc(2)}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This MIB controls the time reference that is applied in the SCTE HMS
tree. It affects how commonTime and alarmLogInformation time reference
are represented.
Set local(1) to represent these values as the number of seconds since
Epoch (00:00:00 UTC, January 1, 1970) adjusted with local time offset.
Set utc(2) to represent these values as the number of seconds since
Epoch (00:00:00 UTC, January 1, 1970).
Deprecated. Has been move into electrolineCommon branch."
::= { dhtCfgGlobal 7 }
-- ****************************************************************************
-- * POWER-SUPPLY RELATED CONFIGURATION DATA
-- *
-- * This branch of the Electroline MIB is available with DHT-PS-NA-01 models in
-- * order to allow configuration of certain legacy application-specific parameters.
-- ****************************************************************************
dhtCfgBatterySave OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This Sub-tree contains the configuration parameters for the DHT's battery
saving mode. This feature allows the DHT to enter sleep mode
when any of the batteries reaches a provisioned critical low voltage.
The DHT will then restart automatically when the battery voltage reaches
the provisioned wakeUp voltage"
::= { dhtCfgPowerSupply 1 }
cfgSleepVoltage OBJECT-TYPE
SYNTAX INTEGER (0..1500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Represents the battery voltage in 1/100 of volts at which the DHT enters
sleep mode."
::= { dhtCfgBatterySave 1 }
cfgWakeUpDeltaVoltage OBJECT-TYPE
SYNTAX INTEGER (0..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This MIB displays the voltage offset at which the DHT will wake up from sleep mode
wake up voltage = sleep voltage + Delta."
::= { dhtCfgBatterySave 2 }
cfgBatterySaveEnable OBJECT-TYPE
SYNTAX INTEGER {enable(1), disable(2), unavailable(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB controls the DHT's battery conservation mode. When set to enable, the DHT
automatically enters sleep mode when the voltage of a battery falls below the value
of cfgSleepVoltage.
The default value is enable.
The value of this MIB is stored in non-volatile memory."
::= { dhtCfgBatterySave 3 }
--
-- *** To uncomment if the support of batterie Lithium-Ion is activated ***
--
--cfgSleepVoltage11x OBJECT-TYPE
-- SYNTAX INTEGER (0..1300)
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Represents the Lithium-Ion 11x battery voltage in 1/100 of volts at which the DHT
-- enters sleep mode."
-- ::= { dhtCfgBatterySave 4 }
--
--cfgWakeUpDeltaVoltage11x OBJECT-TYPE
-- SYNTAX INTEGER (0..500)
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This MIB displays the Lithium-Ion 11x battery voltage offset at which the DHT will
-- wake up from sleep mode wake up voltage = sleep voltage + Delta."
-- ::= { dhtCfgBatterySave 5 }
--
--cfgSleepVoltage14x OBJECT-TYPE
-- SYNTAX INTEGER (0..1750)
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "Represents the Lithium-Ion 14x battery voltage in 1/100 of volts at which the DHT
-- enters sleep mode."
-- ::= { dhtCfgBatterySave 6 }
--
--cfgWakeUpDeltaVoltage14x OBJECT-TYPE
-- SYNTAX INTEGER (0..500)
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This MIB displays the Lithium-Ion 14x battery voltage offset at which the DHT will
-- wake up from sleep mode wake up voltage = sleep voltage + Delta."
-- ::= { dhtCfgBatterySave 7 }
dhtCfgPsInverterTest OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This Sub-tree contains the DHT-specific configuration parameters for
inverter test mode. "
::= { dhtCfgPowerSupply 2 }
cfgPsInvTestAutoStopTimer OBJECT-TYPE
SYNTAX INTEGER (1..300)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB defines the maximum duration of a remote inverter test, in minutes.
The transponder uses a default 15-minute period.
When the timer reaches the end of the set period, the test stops automatically.
Note that the internal Power Supply settings may stop the inverter test
before this timer has expired.
The DHT will also stop the Inverter test if the voltage of any battery drops below
10.875V.
The value of this MIB is stored in non-volatile memory."
::= { dhtCfgPsInverterTest 1 }
-- ****************************************************************************
-- * POWER-SUPPLY SPECIAL SETTINGS
-- *
-- * This branch of the Electroline MIB is available with DHT-PS-NA-01 models in
-- * order to allow configuration of certain parameters that cannot be adjusted
-- * automatically
-- ****************************************************************************
dhtCfgPsSetting OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This Sub-tree contains the PowerSupply specific configuration settings."
::= { dhtCfgPowerSupply 3 }
cfgPsNominalInputVoltage OBJECT-TYPE
SYNTAX INTEGER {oneHundredTwenty(1), twoHundredFourty(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object indicates if the power line input voltage is 120V or 240V.
By default, it is set to 120V.
This object affects all input Voltage reporting (for example psInputVoltage)."
::= { dhtCfgPsSetting 1 }
cfgPsTemperatureCalibrationOffset OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object can be used to increase the accuracy of the psTemperature probe.
The value of this MIB (in 1/10 of degrees Celsius) will be added to the hardware
temperature reading to obtain the value that will be returned in psTemperature.1.1 MIB.
The value of this MIB will be stored in non-volatile memory."
::= { dhtCfgPsSetting 2 }
cfgPsOutputCurrent OBJECT-TYPE
SYNTAX INTEGER {normal(1), high(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object can be used when a XM2 power supply is set in high output current mode.
To follow the power supply mode, you must set this MIB object to high if the power supply is set to
more than 20A. If less than 20A, set it to normal.
Default value is normal.
The value of this MIB will be stored in non-volatile memory."
::= { dhtCfgPsSetting 3 }
dhtCfgUsmUnified OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This Sub-tree contains usm unifed specific configuration settings."
::= { dhtCfgPsSetting 4 }
cfgUsmUnifiedMode OBJECT-TYPE
SYNTAX INTEGER {auto(1), usm(2), usm2(3), usm25(4), apcSm7WithInputCurrent(5), apcSm7WithoutInputCurrent(6)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This mib can be used to force a specific usm card when the unified cable is in used.
auto mode means the dht will perform a discovery at boot up.
You must reboot the transponder after setting this mib.
Default value is auto.
The value of this MIB will be stored in non-volatile memory."
::= { dhtCfgUsmUnified 1 }
cfgPsGenericCreation OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object can be used to force the generic power supply creation.
Default value is false.
The value of this MIB will be stored in non-volatile memory."
::= { dhtCfgPsSetting 5 }
cfgPsMeasurementSource OBJECT-TYPE
SYNTAX INTEGER {analogPort(1), communicationPort(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object allow the user to select the source for the internal measurement
on an XM2 power supply. The choice is either to derive the measurement data from
the transponder's analog port (analogPort(1)) or from the transponder's digital
interface bus (communicationPort(2)). Default value analogPort(1).
The value of this MIB will be stored in non-volatile memory."
::= { dhtCfgPsSetting 6 }
--
-- *** To uncomment if the support of batterie Lithium-Ion is activated ***
--
--cfgPsBatteryType OBJECT-TYPE
-- SYNTAX INTEGER {noBatteryDetected(0), gelBattery6v(1), gelBattery12v(2), lithiumIonBattery(3)}
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This MIB object represents the type of battery detected by the transponder. The detection is
-- done in the boot-up sequence of the transponder."
-- ::= { dhtCfgPsSetting 4 }
-- ****************************************************************************
-- * HMS-022 RELATED CONFIGURATION
-- *
-- * This branch of the Electroline MIB defines some working parameters for the
-- * HMS-022 protocol. (Address range...)
-- ****************************************************************************
dhtCfgHMS022 OBJECT-IDENTITY
STATUS current
DESCRIPTION
"This sections specifies HMS022 specific configuration, it enables the user
to enable select the range of HMS022 address supported."
::= { dhtConfiguration 3 }
cfgStartAddress OBJECT-TYPE
SYNTAX INTEGER (1..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This Mib indecates the starting address of device on the TIB.
If startAdress and EndAddress are equal, only on device will be monitored
The value of this MIB is stored in non-volatile memory."
::= { dhtCfgHMS022 1 }
cfgEndAddress OBJECT-TYPE
SYNTAX INTEGER (1..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This Mib indecates the End address of devices on the TIB.
if startAdress and EndAddress are equal, only on device will be monitored
The value of this MIB is stored in non-volatile memory."
::= { dhtCfgHMS022 2 }
END