-- Copyright 2013 Electroline Equipment Inc
|
|
-- All Rights Reserved
|
|
--
|
|
--
|
|
--
|
|
--*****************************************************************************
|
|
-- Filename: ELECTROLINE-DHT-CONFIG.mib
|
|
-- Author: Eric Alarie
|
|
-- Creation Date: 2003.03.20
|
|
--*****************************************************************************
|
|
-- Description:
|
|
--
|
|
-- This file contains the SNMPv2 MIB definition of the Configuration branch
|
|
-- for the DHT products.
|
|
--
|
|
--*****************************************************************************
|
|
-- Revision History:
|
|
-- 2003.03.20 Eric Alarie First Draft
|
|
-- 2003.03.21 Carlene Gardner Linguistic revision
|
|
-- 2003.05.13 Eric Alarie Updated for release 1.0.x of the DHT
|
|
-- 2003.05.21 Carlene Gardner Linguistic revision
|
|
-- 2003.05.27 Eric Alarie Added Battery save on/off and some
|
|
-- storage for the EMS.
|
|
-- 2003.07.07 Carlene Gardner Linguistic revision
|
|
-- 2004.01.26 Carlene Gardner Added cfgHmsEmsAlarmTrapAssurance
|
|
-- 2004.07.1 Nath Mercure Added cfgPsNominalInputVoltage Mib (120V or 240V)
|
|
-- 2004.07.14 Eric Alarie Added SnmpTimeout MIB
|
|
-- 2004.10.01 Eric Alarie Changed the default value comment for
|
|
-- cfgEmsTimeout and cfgSnmpTimeout.
|
|
-- 2004.12.17 Eric Alarie Added ps temperature calibration MIB for NA01
|
|
-- 2005.06.20 Eric Alarie Added cfgDhtSnmpAgent MIB branch
|
|
-- 2005.06.22 Eric Alarie Added Dual IP MIBs
|
|
-- 2006.02.07 Alain Leclerc changed displayString for octetstring size (0..127)
|
|
-- 2006.02.07 Alain Leclerc autostoptimer must not support a value of 0
|
|
-- 2006.03.20 Louis Roy Added cfgOutputCurrent & modified cfgBatterySaveEnable
|
|
-- 2006.04.25 Eric Alarie cfgEmsCompatibilityMode is obsolete
|
|
-- 2006.08.15 Eric Alarie Added the configuration of the trap port number
|
|
-- 2007.02.21 Louis Roy Added the configuration for the battery Lithium-Ion
|
|
-- 2007.03.02 Louis Roy Added the configuration for the battery type
|
|
-- 2007.03.22 Louis Roy Commented the add for the battery type and Lithium-Ion
|
|
-- 2009.01.08 Alain Leclerc Added support for manual setting in usmUnifed Power supply
|
|
-- 2011.10.13 Louis Roy Added support to manually allow the creation of the Generic Analog Power supply
|
|
-- 2012.03.27 Paul Zheng Added IMPORTS from RFC 4001, the TEXTUAL-CONVENTION for InetAddress and InetAddressType;
|
|
-- added 2 objects cfgHmsEmsAddressTypeInet, cfgHmsEmsAddressInet to support IPv6 address;
|
|
-- deprecate cfgHmsEmsAddressIP;
|
|
-- 2012.03.27 Louis Roy Added a MIB to allow the user to select the source of measurement perform by the DHT
|
|
-- between the communication port or the analog port (cfgPsMeasurementSource)
|
|
-- 2012.06.18 Louis Roy Added a table that allow the provisionning of the Dual IP HMS SNMP access through IP filter
|
|
-- 2013.06.12 Eric Lariviere Added a MIB to allow commonVendorInfo override.
|
|
-- 2013.07.24 Eric Lariviere Added a MIB to control how HMS Mibs represent time.
|
|
-- 2014-01-14 Alain Leclerc Some mibs are depricated
|
|
--
|
|
--*****************************************************************************
|
|
|
|
ELECTROLINE-DHT-CONFIG-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Integer32
|
|
FROM SNMPv2-SMI
|
|
RowStatus, TruthValue
|
|
FROM SNMPv2-TC
|
|
dhtConfiguration
|
|
FROM ELECTROLINE-DHT-ROOT-MIB
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
NetworkAddress
|
|
FROM RFC1155-SMI
|
|
InetAddress,
|
|
InetAddressType
|
|
FROM INET-ADDRESS-MIB; -- RFC 4001
|
|
-- ****************************************************************************
|
|
-- * Definition of Configuration Sub-groups
|
|
-- ****************************************************************************
|
|
dhtCfgGlobal OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Group of configuration objects related to all DHT models"
|
|
::= { dhtConfiguration 1 }
|
|
|
|
dhtCfgPowerSupply OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Group of configuration objects related to the DHT-PS-NA-01 model only"
|
|
::= { dhtConfiguration 2 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- * EMS CONFIGURATION DATA
|
|
-- *
|
|
-- * The following MIB objects control communication (Traps) with external Element
|
|
-- * / Network Management Systems. It includes the EMS Address Table that is used to
|
|
-- * indicate to the DHT the IP addresses of the EMS / NMS and related parameters.
|
|
-- * The HmsCold / Warm start trap assurance mechanism is an Electroline enhancement
|
|
-- * that is required for the EEMS. See ELECTROLINE-DHT-STATUS.mib for further
|
|
-- * details.
|
|
-- ****************************************************************************
|
|
dhtCfgHmsEms OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sub-tree contains configuration information for trap management."
|
|
::= { dhtCfgGlobal 1 }
|
|
|
|
cfgHmsEmsAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CfgHmsEmsAddressEntry
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the list of network addresses of the Element Management System(s)
|
|
to which the DHT will send its HmsColdStart, HmsWarmStart and HmsAlarmEvent traps.
|
|
|
|
The entries in this table are stored in non-volatile memory.
|
|
A maximum of 10 entries is supported.
|
|
"
|
|
::= { dhtCfgHmsEms 1 }
|
|
|
|
cfgHmsEmsAddressEntry OBJECT-TYPE
|
|
SYNTAX CfgHmsEmsAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HMS EMS entry definition"
|
|
INDEX { cfgHmsEmsAddressIndex }
|
|
::= { cfgHmsEmsAddressTable 1 }
|
|
|
|
CfgHmsEmsAddressEntry ::=
|
|
SEQUENCE
|
|
{
|
|
cfgHmsEmsAddressIndex INTEGER,
|
|
cfgHmsEmsAddressIP IpAddress,
|
|
cfgHmsEmsAddressStartTrapAssurance TruthValue,
|
|
cfgHmsEmsAddressAlarmTrapAssurance TruthValue,
|
|
|
|
cfgHmsEmsAddressTrapPortNumber INTEGER,
|
|
cfgHmsEmsAddressTypeInet InetAddressType,
|
|
cfgHmsEmsAddressInet InetAddress,
|
|
|
|
}
|
|
|
|
cfgHmsEmsAddressIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index into the EMS address table"
|
|
::= { cfgHmsEmsAddressEntry 1 }
|
|
|
|
cfgHmsEmsAddressIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"IPv4 address of the destination EMS that will receive HMS traps.
|
|
If the EMS server address is unknown or is not an IPv4 address, return 0.0.0.0..
|
|
Valide IPv4 address set will update also cfgHmsEmsAddressInet and cfgHmsEmsAddressTypeInet.
|
|
This object is deprecated and is replaced by cfgHmsEmsAddressInet."
|
|
::= { cfgHmsEmsAddressEntry 2 }
|
|
|
|
cfgHmsEmsAddressStartTrapAssurance OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this MIB is set to one, additional binding is appended to
|
|
the cold or warm start Trap (HMS). The EMS must set the bound OID
|
|
to 1 to acknowledge receipt of the trap. The DHT then uses the
|
|
cfgEmsTimeout & cfgEmsRetry to resend the trap if necessary."
|
|
::= { cfgHmsEmsAddressEntry 3 }
|
|
|
|
cfgHmsEmsAddressAlarmTrapAssurance OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this MIB is set to true, additional binding is appended to all
|
|
the Alarm Traps (HMS). The EMS must set the bound OID
|
|
to x to acknowledge receipt of the trap (where x is the total number of traps received).
|
|
The DHT then uses the cfgEmsTimeout & cfgEmsRetry to send an AlarmAssurance trap
|
|
if necessary."
|
|
::= { cfgHmsEmsAddressEntry 4 }
|
|
|
|
cfgHmsEmsAddressTrapPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This represents the Ems's port number to which the trap will be sent to.
|
|
The default value is the common SNMP trap port (162)."
|
|
::= { cfgHmsEmsAddressEntry 5 }
|
|
|
|
cfgHmsEmsAddressTypeInet OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The address type of the EMS server.
|
|
Values: unknown(0), ipv4(1), ipv6(2), ipv4z(3), ipv6z(4), dns(16)
|
|
The update of this object is coherent to cfgHmsEmsAddressIP object."
|
|
::= { cfgHmsEmsAddressEntry 6 }
|
|
|
|
cfgHmsEmsAddressInet OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv4 or IPv6 address of the destination EMS that will receive traps.
|
|
If the message server is unknown, return the zero-length address string.
|
|
The update of this object is coherent to cfgHmsEmsAddressIP object."
|
|
::= { cfgHmsEmsAddressEntry 7}
|
|
|
|
|
|
cfgEmsTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (1..86400)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the period of time (in seconds) during which the DHT expects to receive
|
|
an acknowlege trap from an EMS that has enabled trap assurance. If no acknowledge message
|
|
is received after the period has elapsed, the DHT then resends the trap. This process is
|
|
repeated until either the command is successful or the number of retries defined in cfgEmsRetry
|
|
has been reached.
|
|
The same timeout value is used for all destination EMS entries.
|
|
The default value for this MIB is 300 seconds
|
|
The value of this MIB is stored in non-volatile memory.
|
|
"
|
|
::= { dhtCfgHmsEms 2 }
|
|
|
|
cfgEmsRetry OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the number of times that the DHT resends a trap to an EMS that has
|
|
enabled the trap assurance, if no acknowledge message is received.
|
|
The default value is zero, meaning that the traps are never resent; a value
|
|
of -1 means that there is no limit on the number of retries.
|
|
The same retry count value is used for all EMS entries.
|
|
The value of this MIB is stored in non-volatile memory.
|
|
"
|
|
::= { dhtCfgHmsEms 3 }
|
|
|
|
|
|
cfgEmsDefaultHmsProperties OBJECT-TYPE
|
|
SYNTAX INTEGER {setToDefault(1)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB can be used to reset all HMS properties (both analog and
|
|
discrete table entries) to their factory default values."
|
|
::= { dhtCfgHmsEms 4 }
|
|
|
|
cfgEmsCompatibilityMode OBJECT-TYPE
|
|
SYNTAX INTEGER {hmsMode(0), dhtMode(1)}
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This MIB is not currently supported by the DHT "
|
|
::= { dhtCfgHmsEms 5 }
|
|
|
|
cfgEmsXpdrName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..127))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB is used by the EEMS software. Its value has no impact on the DHT's
|
|
operation, but is stored in its non-volatile memory"
|
|
::= { dhtCfgHmsEms 6 }
|
|
|
|
cfgEmsXpdrLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..127))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB is used by the EEMS software. Its value has no impact on the DHT's
|
|
operation, but is stored in its non-volatile memory"
|
|
::= { dhtCfgHmsEms 7 }
|
|
|
|
cfgEmsXpdrDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..127))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB is used by the EEMS software. Its value has no impact on the DHT's
|
|
operation, but is stored in its non-volatile memory"
|
|
::= { dhtCfgHmsEms 8 }
|
|
|
|
cfgEmsXpdrGroupPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..127))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB is used by the EEMS software to indicate the logical group to
|
|
which this DHT belongs. This value has no impact on the DHT's operation, but is stored in
|
|
its non-volatile memory"
|
|
::= { dhtCfgHmsEms 9 }
|
|
|
|
cfgEmsXpdrCustomField1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..127))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB is used by the EEMS software to store user-defined data on
|
|
this DHT. This value has no impact on the DHT's operation, but is stored in
|
|
its non-volatile memory"
|
|
::= { dhtCfgHmsEms 10 }
|
|
|
|
cfgEmsXpdrCustomField2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..127))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB is used by the EEMS software to store user-defined data on
|
|
this DHT. This value has no impact on the DHT's operation, but is stored in
|
|
its non-volatile memory"
|
|
::= { dhtCfgHmsEms 11 }
|
|
|
|
cfgEmsXpdrCustomField3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..127))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB is used by the EEMS software to store user-defined data on
|
|
this DHT. This value has no impact on the DHT's operation, but is stored in
|
|
its non-volatile memory"
|
|
::= { dhtCfgHmsEms 12 }
|
|
|
|
-- ****************************************************************************
|
|
-- * GLOBAL CONFIGURATION DATA
|
|
-- *
|
|
-- * These MIB objects control some functions of the DHT that cannot be set
|
|
-- * through HMS or DOCSIS MIBs.
|
|
-- ****************************************************************************
|
|
dhtCfgResetToFactory OBJECT-TYPE
|
|
SYNTAX INTEGER {reset(1)}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This MIB can be used to remotely restore the factory default values, thus overwriting
|
|
any other setup values (HMS and internal transponder settings) that were stored
|
|
in the DHT's non-volatile memory. The transponder must be reset following this
|
|
command (commonReset or other reset function).
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
|
|
::= { dhtCfgGlobal 2 }
|
|
|
|
dhtCfgUsbMode OBJECT-TYPE
|
|
SYNTAX INTEGER {disable(0), cpe(1), craft(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This MIB controls the behavior of the USB port. In craft mode, the USB port
|
|
has a default MAC address which enables a PC to be connected locally to
|
|
any DHT with the same driver and network adapter settings.
|
|
In craft mode, read access to the DOCSIS MIBS and read/write access to the HMS is allowed.
|
|
In CPE mode, the USB port behaves like a normal cable modem USB port,
|
|
allowing access to the network if this access has been provisioned by the CMTS.
|
|
In CPE mode, access to the MIBs is as per DOCSIS specifications. As well, read-write
|
|
access to the Electroline MIBs is permitted.
|
|
The transponder must be reset following this command (commonReset or other
|
|
reset function) in order for the change to take effect.
|
|
The value of this MIB is stored in non-volatile memory.
|
|
Deprecated. Has been move into electrolineCommon branch.
|
|
See cfgLocalInterfaceMode"
|
|
::= { dhtCfgGlobal 3 }
|
|
|
|
-- ****************************************************************************
|
|
-- * TIMING RELATED CONFIGURATION DATA
|
|
-- *
|
|
-- * This branch of the Electroline MIB allows configuration of certain timings
|
|
-- * in the DHT's operation
|
|
-- ****************************************************************************
|
|
dhtCfgTimers OBJECT-IDENTITY
|
|
STATUS deprecated
|
|
DESCRIPTION "Group of configuration objects related to DHT timing.
|
|
Deprecated. Has been move into electrolineCommon branch"
|
|
::= { dhtCfgGlobal 4 }
|
|
|
|
cfgSnmpTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..10080)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This MIB controls the SNMP activity watchdog period. The value is in minutes.
|
|
A value of zero deactivates the feature. When the feature is active, if the DHT
|
|
does NOT receive any SNMP packets during the period, the DHT will reset.
|
|
The value of this MIB is stored in non-volatile memory. Default value is 0 (off).
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
::= { dhtCfgTimers 1 }
|
|
|
|
-- ****************************************************************************
|
|
-- * Dual IP RELATED CONFIGURATION
|
|
-- *
|
|
-- * This branch of the Electroline MIB should be used to control the IP behavior
|
|
-- * of the DHT, it controls if the monitoring part of the DHT will be accessible
|
|
-- * from the DOCSIS SNMP agent or through a separate SNMP agent.
|
|
-- ****************************************************************************
|
|
dhtCfgIpInterfaces OBJECT-IDENTITY
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This sections specifies IP behavior for the DHT monitoring interface.
|
|
This section has been move to the electroline Common branch"
|
|
::= { dhtCfgGlobal 5 }
|
|
|
|
|
|
cfgDhtIpMode OBJECT-TYPE
|
|
SYNTAX INTEGER {singleIp(1), dualIp(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object controls the IP interface behavior of the DHT
|
|
|
|
Set it to singleIp(1) to access HMS MIB objects through the DOCSIS management interface.
|
|
|
|
Set it to dualIp(2) to instruct the DHT to manage a virtual CPE with a separate IP address
|
|
and a separate SNMP agent to access the HMS MIBs.
|
|
|
|
The default value for this MIB is singleIp(1).
|
|
|
|
A transponder reset after setting this MIB is necessary in order for the change to take effect.
|
|
|
|
The value of this MIB is stored in non-volatile memory.
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
|
|
::= { dhtCfgIpInterfaces 1 }
|
|
|
|
cfgHmsSnmpAgent OBJECT-IDENTITY
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This sections specifies controls for the agents.
|
|
This section has been move to electrolineCommon branch"
|
|
::= { dhtCfgIpInterfaces 50 }
|
|
|
|
hmsSnmpManagerCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This MIB is used to specify the SNMP community string
|
|
used for write access to the SNMP agent in Dual IP mode.
|
|
|
|
The default value for this MIB is DhtHmsWriteSecret.
|
|
|
|
The value of this MIB is stored in non-volatile memory.
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
::= { cfgHmsSnmpAgent 1 }
|
|
|
|
hmsSnmpMonitorCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This MIB is used to specify the SNMP Read-only community string
|
|
used to access the SNMP agent in Dual IP mode.
|
|
|
|
The default value for this MIB is DhtHmsReadSecret.
|
|
|
|
The value of this MIB is stored in non-volatile memory.
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
::= { cfgHmsSnmpAgent 2 }
|
|
|
|
cfgHmsSnmpAccess OBJECT-IDENTITY
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This sub-tree contains configuration information for HMS SNMP access management.
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
::= { cfgHmsSnmpAgent 3 }
|
|
|
|
cfgHmsSnmpAccessTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CfgHmsSnmpAccessEntry
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This table allow access to SNMP objects by network management stations. If the table
|
|
is empty, access to SNMP objects is unrestricted.
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
::= { cfgHmsSnmpAccess 1 }
|
|
|
|
cfgHmsSnmpAccessEntry OBJECT-TYPE
|
|
SYNTAX CfgHmsSnmpAccessEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"HMS SNMP Access entry definition
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
INDEX { cfgHmsSnmpAccessIndex }
|
|
::= { cfgHmsSnmpAccessTable 1 }
|
|
|
|
CfgHmsSnmpAccessEntry ::=
|
|
SEQUENCE
|
|
{
|
|
cfgHmsSnmpAccessIndex INTEGER,
|
|
cfgHmsSnmpAccessIP IpAddress,
|
|
cfgHmsSnmpAccessIPMask IpAddress,
|
|
}
|
|
|
|
cfgHmsSnmpAccessIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index into the HMS SNMP access table.
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
::= { cfgHmsSnmpAccessEntry 1 }
|
|
|
|
cfgHmsSnmpAccessIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"IPv4 address of the network management station.
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
::= { cfgHmsSnmpAccessEntry 2 }
|
|
|
|
cfgHmsSnmpAccessIPMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"IPv4 subnet mask of the network management station"
|
|
::= { cfgHmsSnmpAccessEntry 3 }
|
|
|
|
-- ****************************************************************************
|
|
-- * GLOBAL CONFIGURATION DATA
|
|
-- *
|
|
-- * These MIB objects control some functions of the DHT that cannot be set
|
|
-- * through HMS or DOCSIS MIBs.
|
|
-- ****************************************************************************
|
|
dhtCfgVendorInfo OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Vendor-specific information in human-readable format. When set, it mirrors and
|
|
overrides the mib commonVendorInfo from the SCTE tree.
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
::= { dhtCfgGlobal 6 }
|
|
|
|
dhtCfgHmsTimeReference OBJECT-TYPE
|
|
SYNTAX INTEGER {local(1), utc(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This MIB controls the time reference that is applied in the SCTE HMS
|
|
tree. It affects how commonTime and alarmLogInformation time reference
|
|
are represented.
|
|
|
|
Set local(1) to represent these values as the number of seconds since
|
|
Epoch (00:00:00 UTC, January 1, 1970) adjusted with local time offset.
|
|
|
|
Set utc(2) to represent these values as the number of seconds since
|
|
Epoch (00:00:00 UTC, January 1, 1970).
|
|
Deprecated. Has been move into electrolineCommon branch."
|
|
::= { dhtCfgGlobal 7 }
|
|
|
|
-- ****************************************************************************
|
|
-- * POWER-SUPPLY RELATED CONFIGURATION DATA
|
|
-- *
|
|
-- * This branch of the Electroline MIB is available with DHT-PS-NA-01 models in
|
|
-- * order to allow configuration of certain legacy application-specific parameters.
|
|
-- ****************************************************************************
|
|
dhtCfgBatterySave OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Sub-tree contains the configuration parameters for the DHT's battery
|
|
saving mode. This feature allows the DHT to enter sleep mode
|
|
when any of the batteries reaches a provisioned critical low voltage.
|
|
The DHT will then restart automatically when the battery voltage reaches
|
|
the provisioned wakeUp voltage"
|
|
::= { dhtCfgPowerSupply 1 }
|
|
|
|
cfgSleepVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1500)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the battery voltage in 1/100 of volts at which the DHT enters
|
|
sleep mode."
|
|
::= { dhtCfgBatterySave 1 }
|
|
|
|
cfgWakeUpDeltaVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..500)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB displays the voltage offset at which the DHT will wake up from sleep mode
|
|
wake up voltage = sleep voltage + Delta."
|
|
::= { dhtCfgBatterySave 2 }
|
|
|
|
cfgBatterySaveEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {enable(1), disable(2), unavailable(3)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB controls the DHT's battery conservation mode. When set to enable, the DHT
|
|
automatically enters sleep mode when the voltage of a battery falls below the value
|
|
of cfgSleepVoltage.
|
|
The default value is enable.
|
|
The value of this MIB is stored in non-volatile memory."
|
|
::= { dhtCfgBatterySave 3 }
|
|
|
|
--
|
|
-- *** To uncomment if the support of batterie Lithium-Ion is activated ***
|
|
--
|
|
--cfgSleepVoltage11x OBJECT-TYPE
|
|
-- SYNTAX INTEGER (0..1300)
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Represents the Lithium-Ion 11x battery voltage in 1/100 of volts at which the DHT
|
|
-- enters sleep mode."
|
|
-- ::= { dhtCfgBatterySave 4 }
|
|
--
|
|
--cfgWakeUpDeltaVoltage11x OBJECT-TYPE
|
|
-- SYNTAX INTEGER (0..500)
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This MIB displays the Lithium-Ion 11x battery voltage offset at which the DHT will
|
|
-- wake up from sleep mode wake up voltage = sleep voltage + Delta."
|
|
-- ::= { dhtCfgBatterySave 5 }
|
|
--
|
|
--cfgSleepVoltage14x OBJECT-TYPE
|
|
-- SYNTAX INTEGER (0..1750)
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Represents the Lithium-Ion 14x battery voltage in 1/100 of volts at which the DHT
|
|
-- enters sleep mode."
|
|
-- ::= { dhtCfgBatterySave 6 }
|
|
--
|
|
--cfgWakeUpDeltaVoltage14x OBJECT-TYPE
|
|
-- SYNTAX INTEGER (0..500)
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This MIB displays the Lithium-Ion 14x battery voltage offset at which the DHT will
|
|
-- wake up from sleep mode wake up voltage = sleep voltage + Delta."
|
|
-- ::= { dhtCfgBatterySave 7 }
|
|
|
|
dhtCfgPsInverterTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Sub-tree contains the DHT-specific configuration parameters for
|
|
inverter test mode. "
|
|
::= { dhtCfgPowerSupply 2 }
|
|
|
|
|
|
cfgPsInvTestAutoStopTimer OBJECT-TYPE
|
|
SYNTAX INTEGER (1..300)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB defines the maximum duration of a remote inverter test, in minutes.
|
|
The transponder uses a default 15-minute period.
|
|
When the timer reaches the end of the set period, the test stops automatically.
|
|
|
|
Note that the internal Power Supply settings may stop the inverter test
|
|
before this timer has expired.
|
|
|
|
The DHT will also stop the Inverter test if the voltage of any battery drops below
|
|
10.875V.
|
|
|
|
The value of this MIB is stored in non-volatile memory."
|
|
::= { dhtCfgPsInverterTest 1 }
|
|
|
|
-- ****************************************************************************
|
|
-- * POWER-SUPPLY SPECIAL SETTINGS
|
|
-- *
|
|
-- * This branch of the Electroline MIB is available with DHT-PS-NA-01 models in
|
|
-- * order to allow configuration of certain parameters that cannot be adjusted
|
|
-- * automatically
|
|
-- ****************************************************************************
|
|
dhtCfgPsSetting OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Sub-tree contains the PowerSupply specific configuration settings."
|
|
::= { dhtCfgPowerSupply 3 }
|
|
|
|
|
|
cfgPsNominalInputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER {oneHundredTwenty(1), twoHundredFourty(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object indicates if the power line input voltage is 120V or 240V.
|
|
By default, it is set to 120V.
|
|
This object affects all input Voltage reporting (for example psInputVoltage)."
|
|
::= { dhtCfgPsSetting 1 }
|
|
|
|
cfgPsTemperatureCalibrationOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object can be used to increase the accuracy of the psTemperature probe.
|
|
The value of this MIB (in 1/10 of degrees Celsius) will be added to the hardware
|
|
temperature reading to obtain the value that will be returned in psTemperature.1.1 MIB.
|
|
|
|
The value of this MIB will be stored in non-volatile memory."
|
|
::= { dhtCfgPsSetting 2 }
|
|
|
|
cfgPsOutputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER {normal(1), high(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object can be used when a XM2 power supply is set in high output current mode.
|
|
To follow the power supply mode, you must set this MIB object to high if the power supply is set to
|
|
more than 20A. If less than 20A, set it to normal.
|
|
Default value is normal.
|
|
|
|
The value of this MIB will be stored in non-volatile memory."
|
|
::= { dhtCfgPsSetting 3 }
|
|
|
|
dhtCfgUsmUnified OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Sub-tree contains usm unifed specific configuration settings."
|
|
::= { dhtCfgPsSetting 4 }
|
|
|
|
cfgUsmUnifiedMode OBJECT-TYPE
|
|
SYNTAX INTEGER {auto(1), usm(2), usm2(3), usm25(4), apcSm7WithInputCurrent(5), apcSm7WithoutInputCurrent(6)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This mib can be used to force a specific usm card when the unified cable is in used.
|
|
auto mode means the dht will perform a discovery at boot up.
|
|
You must reboot the transponder after setting this mib.
|
|
Default value is auto.
|
|
|
|
The value of this MIB will be stored in non-volatile memory."
|
|
::= { dhtCfgUsmUnified 1 }
|
|
|
|
|
|
cfgPsGenericCreation OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object can be used to force the generic power supply creation.
|
|
Default value is false.
|
|
|
|
The value of this MIB will be stored in non-volatile memory."
|
|
::= { dhtCfgPsSetting 5 }
|
|
|
|
cfgPsMeasurementSource OBJECT-TYPE
|
|
SYNTAX INTEGER {analogPort(1), communicationPort(2)}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object allow the user to select the source for the internal measurement
|
|
on an XM2 power supply. The choice is either to derive the measurement data from
|
|
the transponder's analog port (analogPort(1)) or from the transponder's digital
|
|
interface bus (communicationPort(2)). Default value analogPort(1).
|
|
|
|
The value of this MIB will be stored in non-volatile memory."
|
|
::= { dhtCfgPsSetting 6 }
|
|
|
|
|
|
--
|
|
-- *** To uncomment if the support of batterie Lithium-Ion is activated ***
|
|
--
|
|
--cfgPsBatteryType OBJECT-TYPE
|
|
-- SYNTAX INTEGER {noBatteryDetected(0), gelBattery6v(1), gelBattery12v(2), lithiumIonBattery(3)}
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This MIB object represents the type of battery detected by the transponder. The detection is
|
|
-- done in the boot-up sequence of the transponder."
|
|
-- ::= { dhtCfgPsSetting 4 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- * HMS-022 RELATED CONFIGURATION
|
|
-- *
|
|
-- * This branch of the Electroline MIB defines some working parameters for the
|
|
-- * HMS-022 protocol. (Address range...)
|
|
-- ****************************************************************************
|
|
dhtCfgHMS022 OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sections specifies HMS022 specific configuration, it enables the user
|
|
to enable select the range of HMS022 address supported."
|
|
::= { dhtConfiguration 3 }
|
|
|
|
|
|
cfgStartAddress OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Mib indecates the starting address of device on the TIB.
|
|
|
|
If startAdress and EndAddress are equal, only on device will be monitored
|
|
|
|
The value of this MIB is stored in non-volatile memory."
|
|
::= { dhtCfgHMS022 1 }
|
|
|
|
cfgEndAddress OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Mib indecates the End address of devices on the TIB.
|
|
|
|
if startAdress and EndAddress are equal, only on device will be monitored
|
|
|
|
The value of this MIB is stored in non-volatile memory."
|
|
::= { dhtCfgHMS022 2 }
|
|
|
|
|
|
END
|