Observium_CE/mibs/dell/DELL-POWER-ETHERNET-MIB

437 lines
16 KiB
Plaintext

DELL-POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN
-- Copyright 2016-2020 Broadcom.
-- This SNMP Management Information Specification
-- embodies Broadcom's confidential and proprietary
-- intellectual property. Broadcom retains all title
-- and ownership in the Specification including any revisions.
-- This Specification is supplied "AS IS", Broadcom
-- makes no warranty, either expressed or implied,
-- as to the use, operation, condition, or performance of the
-- Specification.
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32 FROM SNMPv2-SMI
TruthValue FROM SNMPv2-TC
dnOS FROM DELL-REF-MIB
DisplayString FROM RFC1213-MIB
pethPsePortEntry, pethMainPseEntry FROM POWER-ETHERNET-MIB;
fastPathpowerEthernetMIB MODULE-IDENTITY
LAST-UPDATED "202005110000Z" -- 11 May 2020 12:00:00 GMT
ORGANIZATION "Dell"
CONTACT-INFO ""
DESCRIPTION
"This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet
Interfaces and Hub MIB Working Group for managing Power Source
Equipment (PSE). The objects in this MIB are intended to provide
additional objects for reporting information available to the hardware
on this platform which are not represented in the draft MIB."
-- Revision history.
REVISION
"202005110000Z" -- 11 May 2020 12:00:00 GMT
DESCRIPTION
"pre-dot3bt, type3 and dot3bt support added in object
agentPethHighPowerMode to support 802.3bt feature.
dot3btonly(4) and dot3btandlegacy(5) options are added to
agentPethPowerDetectionType to support 802.3bt feature.
Added agentPethPowerClassifications object to get the Class
in agentPethPsePortTable."
REVISION
"201803020000Z" -- 02 Mar 2018 12:00:00 GMT
DESCRIPTION
"Deprecated agentPethPoeMainPseThresholdPower and
agentPethPoeMainPseUsageThreshold objects from
agentPethPoeMainPseObjects group as threshold
should be maintained for unit (system) instead of per slot.
Threshold Power is not present in agentPethPseTable, hence
added agentPethPseThresholdPower in agentPethPseTable."
REVISION
"201801250000Z" -- 25 Jan 2018 12:00:00 GMT
DESCRIPTION
"agentPethPoeMainPseObjects Group is added to get/set the
PoE System Data for all slots in a unit."
REVISION
"201503130000Z" -- 13 Mar 2015 12:00:00 GMT
DESCRIPTION
"PoE Plus support is added.
agentPethPsePowerManagementMode object description is updated."
REVISION
"201404160000Z" -- 16 Apr 2014 12:00:00 GMT
DESCRIPTION
"Upoe support added in new object agentPethHighPowerMode."
REVISION
"201101260000Z" -- 26 Jan 2011 12:00:00 GMT
DESCRIPTION
"Postal address updated."
REVISION
"200708191200Z" -- 17 Aug 2007 12:00:00 GMT
DESCRIPTION
"PoE support for BCM59101 added."
REVISION
"200705230000Z" -- 23 May 2007 12:00:00 GMT
DESCRIPTION
"Dell branding related changes."
REVISION
"200311101200Z" -- 10 Nov 2003 12:00:00 GMT
DESCRIPTION
"Initial revision."
::= { dnOS 15 }
agentPethObjects OBJECT IDENTIFIER ::= { fastPathpowerEthernetMIB 1 }
agentPethPsePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentPethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of per-port information and configuration objects relating
to the power status of each port."
::= { agentPethObjects 1 }
agentPethPsePortEntry OBJECT-TYPE
SYNTAX AgentPethPsePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of objects providing additional power information
and control parameters for the specified port."
AUGMENTS { pethPsePortEntry }
::= { agentPethPsePortTable 1 }
AgentPethPsePortEntry ::= SEQUENCE {
agentPethPowerLimit
Gauge32,
agentPethOutputPower
Gauge32,
agentPethOutputCurrent
Gauge32,
agentPethOutputVolts
Gauge32,
agentPethTemperature
Gauge32,
agentPethPowerLimitType
INTEGER,
agentPethHighPowerEnable
TruthValue,
agentPethPowerDetectionType
INTEGER,
agentPethFaultStatus
INTEGER,
agentPethPortReset
INTEGER,
agentPethPowerLimitMin
Gauge32,
agentPethPowerLimitMax
Gauge32,
agentPethPowerClassifications
INTEGER
}
agentPethPowerLimit OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliwatts"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The configured maximum power this port can provide to an
attached device measured in Milliwatts."
::= { agentPethPsePortEntry 1 }
agentPethOutputPower OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliwatts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power this port is supplying to an attached device measured
in Milliwatts."
::= { agentPethPsePortEntry 2 }
agentPethOutputCurrent OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliamps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current this port is supplying to an attached device measured
in Milliamps."
::= { agentPethPsePortEntry 3 }
agentPethOutputVolts OBJECT-TYPE
SYNTAX Gauge32
UNITS "Volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The voltage this port is supplying to an attached device measured
in Volts."
::= { agentPethPsePortEntry 4 }
agentPethTemperature OBJECT-TYPE
SYNTAX Gauge32
UNITS "DEGREES"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The temperature measured at this port of the PoE Controller. It is
measured in degree celcius."
::= { agentPethPsePortEntry 5 }
agentPethPowerLimitType OBJECT-TYPE
SYNTAX INTEGER {
dot3at(1),
user(2),
none(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the maximum power that a port can deliver.
A value of dot3at(1) means that the port power limit is as per
the dot3at class of the PD attached.
A value of user(2) means that the port power limit is equal to the value
specified by agentPethPowerLimit"
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3at"
::= { agentPethPsePortEntry 6 }
agentPethHighPowerEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"true (1) The PSE port can deliver power up to 32Watts.
false(2) The PSE port can deliver power up to 18Watts"
REFERENCE
"Broadcom 5910X programmers guide"
::= { agentPethPsePortEntry 7 }
agentPethPowerDetectionType OBJECT-TYPE
SYNTAX INTEGER {
none(0),
dot3atonly(2),
dot3atandlegacy(3),
dot3btonly(4),
dot3btandlegacy(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes PD detection mechanism performed by the PSE port.
A value of none(0) means no detection is done.
A value of dot3atonly(2) means that IEEE 802.3at detection scheme is used.
A value of dot3atandlegacy(3) means that IEEE 802.3at detection scheme
is used and when that fails to detect a connected PD, legacity capacitive detection
is used.
A value of dot3btonly(4) means that IEEE 802.3bt detection scheme is used.
A value of dot3btandlegacy(5) means that IEEE 802.3bt detection scheme
is used and when that fails to detect a connected PD, legacity capacitive detection
is used.
The value 'none' can not be forcibly set by the administrator."
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3at"
::= { agentPethPsePortEntry 8 }
agentPethFaultStatus OBJECT-TYPE
SYNTAX INTEGER {
none(0),
mpsAbsent(1),
short(2),
overload(3),
powerDenied(4),
thermalShutdown(5),
startupFailure(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Describes the error description when the pse port is in fault status.
A value of none(0) specifies that the pse port is not in any error state.
A value of mpsAbsent(1) specifies that the pse port has detected and absence
of main power supply.
A value of short(2) specifies that the pse port has detected a short circuit
condition.
A value of overload(3) specifies that the pd connected to the pse port had tried
to draw more power than permissible by the hardware.
A value of powerDenied(4) specifies that the pse port has been denied power
because of shortage of power or due to administrative action.
A value of thermalShutdown(5) specifies that the thermal threshold has exceeded
for the pse port.
A value of startupFailure(6) as fault status indicates that the port does not have
sufficient voltage."
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3at"
::= { agentPethPsePortEntry 9 }
agentPethPortReset OBJECT-TYPE
SYNTAX INTEGER {
none(0),
reset(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A value of reset(1) is used to move the pse port dot3at state to idle. A
read on this object will always return the value none(0). The value none(0)
can not be forcibly set by the administrtor."
REFERENCE
"Broadcom 5910X programmers guide, IEEE Std 802.3at"
::= { agentPethPsePortEntry 10 }
agentPethPowerLimitMin OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliwatts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum power this port can be configured to provide, measured in Milliwatts."
::= { agentPethPsePortEntry 11 }
agentPethPowerLimitMax OBJECT-TYPE
SYNTAX Gauge32
UNITS "Milliwatts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum power this port can be configured to provide, measured in Milliwatts."
::= { agentPethPsePortEntry 12 }
agentPethPowerClassifications OBJECT-TYPE
SYNTAX INTEGER {
invalid(0),
class0(1),
class1(2),
class2(3),
class3(4),
class4(5),
class5(6),
class6(7),
class7(8),
class8(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Classification is a way to tag different terminals on the
Power over LAN network according to their power consumption.
Devices such as IP telephones, WLAN access points and others,
will be classified according to their power requirements.
The meaning of the classification labels is defined in the
IEEE specification.
This variable is valid only while a PD is being powered,
that is, while the attribute pethPsePortDetectionStatus
is reporting the enumeration deliveringPower."
::= { agentPethPsePortEntry 13 }
-- Main objects
agentPethMainPseObjects OBJECT IDENTIFIER ::= { agentPethObjects 2 }
agentPethMainPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentPethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of objects that display and control attributes
of the main power source in a PSE device. Ethernet
switches are one example of boxes that would support
these objects.
Values of all read-write objects in this table are
persistent at restart/reboot."
::= { agentPethMainPseObjects 1 }
agentPethMainPseEntry OBJECT-TYPE
SYNTAX AgentPethMainPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A set of objects that display and control the Main
power of a PSE. "
AUGMENTS { pethMainPseEntry }
::= { agentPethMainPseTable 1 }
AgentPethMainPseEntry ::= SEQUENCE {
agentPethMainPseLegacy
TruthValue
}
agentPethMainPseLegacy OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Legacy device detection. The
value true(1) means legacy devices are detected; the
value false(2) means legacy devices are not detected."
::= { agentPethMainPseEntry 1 }
agentPethPseTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentPethPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of per-unit information and configuration objects relating
to the power configurtion for the entire pse unit."
::= { agentPethObjects 3 }
agentPethPseEntry OBJECT-TYPE
SYNTAX AgentPethPseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of objects providing additional power information
and control parameters for the specified pse unit."
AUGMENTS { pethMainPseEntry }
::= { agentPethPseTable 1 }
AgentPethPseEntry ::= SEQUENCE {
agentPethPsePowerManagementMode
INTEGER
,
agentPethPseThresholdPower
Gauge32
}
agentPethPsePowerManagementMode OBJECT-TYPE
SYNTAX INTEGER {
none(0),
dynamic(1),
static(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes or controls the power management algorithm used by the pse
to deliver power to the requesting PDsthat a pds.
A value of dynamic(1) means that power consumption of each port
is measured and calculated in real-time.
A value of static(2) means that power allocated for each port depends
on the type of power threshold configured on the port."
REFERENCE
"Broadcom 5910X programmers guide"
::= { agentPethPseEntry 1 }
agentPethPseThresholdPower OBJECT-TYPE
SYNTAX Gauge32
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Measured usage power expressed in Watts."
::= { agentPethPseEntry 6 }
END