DELL-POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN -- Copyright 2016-2020 Broadcom. -- This SNMP Management Information Specification -- embodies Broadcom's confidential and proprietary -- intellectual property. Broadcom retains all title -- and ownership in the Specification including any revisions. -- This Specification is supplied "AS IS", Broadcom -- makes no warranty, either expressed or implied, -- as to the use, operation, condition, or performance of the -- Specification. IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Integer32, Gauge32 FROM SNMPv2-SMI TruthValue FROM SNMPv2-TC dnOS FROM DELL-REF-MIB DisplayString FROM RFC1213-MIB pethPsePortEntry, pethMainPseEntry FROM POWER-ETHERNET-MIB; fastPathpowerEthernetMIB MODULE-IDENTITY LAST-UPDATED "202005110000Z" -- 11 May 2020 12:00:00 GMT ORGANIZATION "Dell" CONTACT-INFO "" DESCRIPTION "This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet Interfaces and Hub MIB Working Group for managing Power Source Equipment (PSE). The objects in this MIB are intended to provide additional objects for reporting information available to the hardware on this platform which are not represented in the draft MIB." -- Revision history. REVISION "202005110000Z" -- 11 May 2020 12:00:00 GMT DESCRIPTION "pre-dot3bt, type3 and dot3bt support added in object agentPethHighPowerMode to support 802.3bt feature. dot3btonly(4) and dot3btandlegacy(5) options are added to agentPethPowerDetectionType to support 802.3bt feature. Added agentPethPowerClassifications object to get the Class in agentPethPsePortTable." REVISION "201803020000Z" -- 02 Mar 2018 12:00:00 GMT DESCRIPTION "Deprecated agentPethPoeMainPseThresholdPower and agentPethPoeMainPseUsageThreshold objects from agentPethPoeMainPseObjects group as threshold should be maintained for unit (system) instead of per slot. Threshold Power is not present in agentPethPseTable, hence added agentPethPseThresholdPower in agentPethPseTable." REVISION "201801250000Z" -- 25 Jan 2018 12:00:00 GMT DESCRIPTION "agentPethPoeMainPseObjects Group is added to get/set the PoE System Data for all slots in a unit." REVISION "201503130000Z" -- 13 Mar 2015 12:00:00 GMT DESCRIPTION "PoE Plus support is added. agentPethPsePowerManagementMode object description is updated." REVISION "201404160000Z" -- 16 Apr 2014 12:00:00 GMT DESCRIPTION "Upoe support added in new object agentPethHighPowerMode." REVISION "201101260000Z" -- 26 Jan 2011 12:00:00 GMT DESCRIPTION "Postal address updated." REVISION "200708191200Z" -- 17 Aug 2007 12:00:00 GMT DESCRIPTION "PoE support for BCM59101 added." REVISION "200705230000Z" -- 23 May 2007 12:00:00 GMT DESCRIPTION "Dell branding related changes." REVISION "200311101200Z" -- 10 Nov 2003 12:00:00 GMT DESCRIPTION "Initial revision." ::= { dnOS 15 } agentPethObjects OBJECT IDENTIFIER ::= { fastPathpowerEthernetMIB 1 } agentPethPsePortTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentPethPsePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of per-port information and configuration objects relating to the power status of each port." ::= { agentPethObjects 1 } agentPethPsePortEntry OBJECT-TYPE SYNTAX AgentPethPsePortEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of objects providing additional power information and control parameters for the specified port." AUGMENTS { pethPsePortEntry } ::= { agentPethPsePortTable 1 } AgentPethPsePortEntry ::= SEQUENCE { agentPethPowerLimit Gauge32, agentPethOutputPower Gauge32, agentPethOutputCurrent Gauge32, agentPethOutputVolts Gauge32, agentPethTemperature Gauge32, agentPethPowerLimitType INTEGER, agentPethHighPowerEnable TruthValue, agentPethPowerDetectionType INTEGER, agentPethFaultStatus INTEGER, agentPethPortReset INTEGER, agentPethPowerLimitMin Gauge32, agentPethPowerLimitMax Gauge32, agentPethPowerClassifications INTEGER } agentPethPowerLimit OBJECT-TYPE SYNTAX Gauge32 UNITS "Milliwatts" MAX-ACCESS read-write STATUS current DESCRIPTION "The configured maximum power this port can provide to an attached device measured in Milliwatts." ::= { agentPethPsePortEntry 1 } agentPethOutputPower OBJECT-TYPE SYNTAX Gauge32 UNITS "Milliwatts" MAX-ACCESS read-only STATUS current DESCRIPTION "The power this port is supplying to an attached device measured in Milliwatts." ::= { agentPethPsePortEntry 2 } agentPethOutputCurrent OBJECT-TYPE SYNTAX Gauge32 UNITS "Milliamps" MAX-ACCESS read-only STATUS current DESCRIPTION "The current this port is supplying to an attached device measured in Milliamps." ::= { agentPethPsePortEntry 3 } agentPethOutputVolts OBJECT-TYPE SYNTAX Gauge32 UNITS "Volts" MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage this port is supplying to an attached device measured in Volts." ::= { agentPethPsePortEntry 4 } agentPethTemperature OBJECT-TYPE SYNTAX Gauge32 UNITS "DEGREES" MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature measured at this port of the PoE Controller. It is measured in degree celcius." ::= { agentPethPsePortEntry 5 } agentPethPowerLimitType OBJECT-TYPE SYNTAX INTEGER { dot3at(1), user(2), none(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Describes or controls the maximum power that a port can deliver. A value of dot3at(1) means that the port power limit is as per the dot3at class of the PD attached. A value of user(2) means that the port power limit is equal to the value specified by agentPethPowerLimit" REFERENCE "Broadcom 5910X programmers guide, IEEE Std 802.3at" ::= { agentPethPsePortEntry 6 } agentPethHighPowerEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "true (1) The PSE port can deliver power up to 32Watts. false(2) The PSE port can deliver power up to 18Watts" REFERENCE "Broadcom 5910X programmers guide" ::= { agentPethPsePortEntry 7 } agentPethPowerDetectionType OBJECT-TYPE SYNTAX INTEGER { none(0), dot3atonly(2), dot3atandlegacy(3), dot3btonly(4), dot3btandlegacy(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Describes PD detection mechanism performed by the PSE port. A value of none(0) means no detection is done. A value of dot3atonly(2) means that IEEE 802.3at detection scheme is used. A value of dot3atandlegacy(3) means that IEEE 802.3at detection scheme is used and when that fails to detect a connected PD, legacity capacitive detection is used. A value of dot3btonly(4) means that IEEE 802.3bt detection scheme is used. A value of dot3btandlegacy(5) means that IEEE 802.3bt detection scheme is used and when that fails to detect a connected PD, legacity capacitive detection is used. The value 'none' can not be forcibly set by the administrator." REFERENCE "Broadcom 5910X programmers guide, IEEE Std 802.3at" ::= { agentPethPsePortEntry 8 } agentPethFaultStatus OBJECT-TYPE SYNTAX INTEGER { none(0), mpsAbsent(1), short(2), overload(3), powerDenied(4), thermalShutdown(5), startupFailure(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Describes the error description when the pse port is in fault status. A value of none(0) specifies that the pse port is not in any error state. A value of mpsAbsent(1) specifies that the pse port has detected and absence of main power supply. A value of short(2) specifies that the pse port has detected a short circuit condition. A value of overload(3) specifies that the pd connected to the pse port had tried to draw more power than permissible by the hardware. A value of powerDenied(4) specifies that the pse port has been denied power because of shortage of power or due to administrative action. A value of thermalShutdown(5) specifies that the thermal threshold has exceeded for the pse port. A value of startupFailure(6) as fault status indicates that the port does not have sufficient voltage." REFERENCE "Broadcom 5910X programmers guide, IEEE Std 802.3at" ::= { agentPethPsePortEntry 9 } agentPethPortReset OBJECT-TYPE SYNTAX INTEGER { none(0), reset(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "A value of reset(1) is used to move the pse port dot3at state to idle. A read on this object will always return the value none(0). The value none(0) can not be forcibly set by the administrtor." REFERENCE "Broadcom 5910X programmers guide, IEEE Std 802.3at" ::= { agentPethPsePortEntry 10 } agentPethPowerLimitMin OBJECT-TYPE SYNTAX Gauge32 UNITS "Milliwatts" MAX-ACCESS read-only STATUS current DESCRIPTION "The minimum power this port can be configured to provide, measured in Milliwatts." ::= { agentPethPsePortEntry 11 } agentPethPowerLimitMax OBJECT-TYPE SYNTAX Gauge32 UNITS "Milliwatts" MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum power this port can be configured to provide, measured in Milliwatts." ::= { agentPethPsePortEntry 12 } agentPethPowerClassifications OBJECT-TYPE SYNTAX INTEGER { invalid(0), class0(1), class1(2), class2(3), class3(4), class4(5), class5(6), class6(7), class7(8), class8(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "Classification is a way to tag different terminals on the Power over LAN network according to their power consumption. Devices such as IP telephones, WLAN access points and others, will be classified according to their power requirements. The meaning of the classification labels is defined in the IEEE specification. This variable is valid only while a PD is being powered, that is, while the attribute pethPsePortDetectionStatus is reporting the enumeration deliveringPower." ::= { agentPethPsePortEntry 13 } -- Main objects agentPethMainPseObjects OBJECT IDENTIFIER ::= { agentPethObjects 2 } agentPethMainPseTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentPethMainPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of objects that display and control attributes of the main power source in a PSE device. Ethernet switches are one example of boxes that would support these objects. Values of all read-write objects in this table are persistent at restart/reboot." ::= { agentPethMainPseObjects 1 } agentPethMainPseEntry OBJECT-TYPE SYNTAX AgentPethMainPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A set of objects that display and control the Main power of a PSE. " AUGMENTS { pethMainPseEntry } ::= { agentPethMainPseTable 1 } AgentPethMainPseEntry ::= SEQUENCE { agentPethMainPseLegacy TruthValue } agentPethMainPseLegacy OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable Legacy device detection. The value true(1) means legacy devices are detected; the value false(2) means legacy devices are not detected." ::= { agentPethMainPseEntry 1 } agentPethPseTable OBJECT-TYPE SYNTAX SEQUENCE OF AgentPethPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of per-unit information and configuration objects relating to the power configurtion for the entire pse unit." ::= { agentPethObjects 3 } agentPethPseEntry OBJECT-TYPE SYNTAX AgentPethPseEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A collection of objects providing additional power information and control parameters for the specified pse unit." AUGMENTS { pethMainPseEntry } ::= { agentPethPseTable 1 } AgentPethPseEntry ::= SEQUENCE { agentPethPsePowerManagementMode INTEGER , agentPethPseThresholdPower Gauge32 } agentPethPsePowerManagementMode OBJECT-TYPE SYNTAX INTEGER { none(0), dynamic(1), static(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Describes or controls the power management algorithm used by the pse to deliver power to the requesting PDsthat a pds. A value of dynamic(1) means that power consumption of each port is measured and calculated in real-time. A value of static(2) means that power allocated for each port depends on the type of power threshold configured on the port." REFERENCE "Broadcom 5910X programmers guide" ::= { agentPethPseEntry 1 } agentPethPseThresholdPower OBJECT-TYPE SYNTAX Gauge32 UNITS "Watts" MAX-ACCESS read-only STATUS current DESCRIPTION "Measured usage power expressed in Watts." ::= { agentPethPseEntry 6 } END