-- Dell Management Module MIB
-- Management Information Base
--
-- This MIB is intended for use with the OpenManage Enterprise-Modular management software.
--
-- Copyright (c) 2018 Dell Inc.
--
-- Last Changed Revision: 1
-- Last Changed Date: 2018-06-13 13:44:00 -0500 (Wed, 13 Jun 2018)
--
DELL-MM-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
DisplayString
FROM RFC1213-MIB;
-- text convention ------------------------------------------------------------------------
-------------------------------------------------------------------------------
-- This data type is used to model textual information taken
-- from the NVT ASCII character set. By convention, objects
-- with this syntax are declared as having
-- SIZE (0..1023)
-------------------------------------------------------------------------------
DellString ::= DisplayString (SIZE (0..1023))
DellMmType ::= INTEGER
{
other(1), -- the MM type is not one of the following
unknown(2), -- the MM type is unknown
mxMM(3) -- MX Chassis (MM)
}
DellStatus ::= INTEGER
{
other(1), -- the status of the object is not one of the following:
unknown(2), -- the status of the object is unknown
-- (not known or monitored)
ok(3), -- the status of the object is ok
nonCritical(4), -- the status of the object is warning, non-critical
critical(5), -- the status of the object is critical (failure)
nonRecoverable(6) -- the status of the object is non-recoverable (dead)
}
-------------------------------------------------------------------------------
-- DellPowerReading is a string representation of a floating point value,
-- having exactly 3 digits of precision, and a maximum of 31 characters.
--
-- DellChassisPowerIndexRange defines the possible chassis power instances
-- in this MIB.
--
-- DellPSUIndexRange defines the possible Power Supply Unit (PSU)
-- instances, per chassis power instance, in this MIB.
--
-- DellPSUCapable is an enumeration of PSU presence and/or monitoring
-- capabilities.
--
-- DellTemperatureReading is an integer value, expressed in degrees Celsius.
-------------------------------------------------------------------------------
DellPowerReading ::= DisplayString (SIZE (0..32))
DellPowerIndexRange ::= INTEGER (1..1)
DellPSUIndexRange ::= INTEGER (1..6)
DellPSUCapable ::= INTEGER
{
absent(1), -- power supply is not present
none(2), -- no power monitoring abilities
basic(3) -- basic power monitoring abilities
}
DellTemperatureReading ::= INTEGER
-------------------------------------------------------------------------------
-- DellTimestamp is defined in the displayable format:
--
-- yyyymmddHHMMSS.uuuuuuDooo
--
-- where yyyy is the year, mm is the month number, dd is the day of the month,
-- HHMMSS are the hours, minutes and seconds, respectively, uuuuuu is the
-- number of microseconds, D is the UTC offset direction, and ooo is the
-- offset from UTC, in minutes.
--
-- Note: D is a plus (+) sign if east of UTC, and a minus (-) if west of UTC.
--
-- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT
-- would be represented as: 19940525133015.000000-300
-------------------------------------------------------------------------------
DellTimestamp ::= DisplayString (SIZE (26))
-- MIB Objects and Tables --------------------------------------------------------
dell OBJECT IDENTIFIER ::= { enterprises 674 }
server3 OBJECT IDENTIFIER ::= { dell 10892 }
dmmOutOfBandGroup OBJECT IDENTIFIER ::= { server3 6 }
dmmInformationGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 1 }
dmmProductInfoGroup OBJECT IDENTIFIER ::= { dmmInformationGroup 1 }
dmmFirmwareGroup OBJECT IDENTIFIER ::= { dmmInformationGroup 2 }
dmmStatusGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 2 }
dmmChassisStatusGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 3 }
dmmStatusNowGroup OBJECT IDENTIFIER ::= { dmmChassisStatusGroup 1 }
dmmChassisPowerGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 4 }
DmmPowerTableEntry ::= SEQUENCE
{
dmmPowerChassisIndex DellPowerIndexRange,
dmmPowerIdlePower DellPowerReading,
dmmPowerKWhCumulative DellPowerReading,
dmmPowerKWhCumulativeTime DellTimestamp,
dmmPowerWattsPeakUsage DellPowerReading,
dmmPowerWattsPeakTime DellTimestamp,
dmmPowerWattsMinUsage DellPowerReading,
dmmPowerWattsMinTime DellTimestamp,
dmmPowerWattsReading DellPowerReading
}
DmmPSUTableEntry ::= SEQUENCE
{
dmmPSUChassisIndex DellPowerIndexRange,
dmmPSUIndex DellPSUIndexRange,
dmmPSULocation DellString,
dmmPSUState DellString,
dmmPSUType DellString,
dmmPSUCapacity DellPowerReading,
dmmPSUVoltage DellPowerReading,
dmmPSUCurrStatus DellStatus
}
dmmChassisAlert2Group OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 5 }
dmmChassisAlert2Variables OBJECT IDENTIFIER ::= { dmmChassisAlert2Group 1 }
dmmGenericAlertGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 6 }
dmmGenericAlertVariables OBJECT IDENTIFIER ::= { dmmGenericAlertGroup 1 }
-- Variables and Traps ------------------------------------------------------------------------
-------------------------------------------------------------------------------
-- group: product information
-------------------------------------------------------------------------------
dmmProductName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the product name of a chassis management module."
::= { dmmProductInfoGroup 1 }
dmmProductShortName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the short product name of a chassis management module. "
::= { dmmProductInfoGroup 2 }
dmmProductDescription OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the product description of a chassis management module. "
::= { dmmProductInfoGroup 3 }
dmmProductManufacturer OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the product manufacturer of a chassis management module. "
::= { dmmProductInfoGroup 4 }
dmmProductVersion OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the product version of a chassis management module. "
::= { dmmProductInfoGroup 5 }
dmmChassisServiceTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Service Tag of the chassis. "
::= { dmmProductInfoGroup 6 }
dmmProductURL OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the out-of-band UI URL of a chassis management module. "
::= { dmmProductInfoGroup 7 }
dmmProductChassisAssetTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Asset Tag of the chassis. "
::= { dmmProductInfoGroup 8 }
dmmProductChassisName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the name of the chassis. "
::= { dmmProductInfoGroup 9 }
dmmProductType OBJECT-TYPE
SYNTAX DellMmType
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines type of a remote management module "
::= { dmmProductInfoGroup 10 }
dmmProductChassisDataCenter OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Data Center locator of the chassis. "
::= { dmmProductInfoGroup 11 }
dmmProductChassisAisle OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Aisle locator of the chassis. "
::= { dmmProductInfoGroup 12 }
dmmProductChassisRack OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Rack locator of the chassis. "
::= { dmmProductInfoGroup 13 }
dmmProductChassisRackSlot OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Rack Slot locator of the chassis. "
::= { dmmProductInfoGroup 14 }
dmmProductChassisModel OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Model of the chassis."
::= { dmmProductInfoGroup 15 }
dmmProductChassisExpressServiceCode OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Express Service Code of the chassis."
::= { dmmProductInfoGroup 16 }
dmmProductChassisSystemID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the System ID of the chassis."
::= { dmmProductInfoGroup 17 }
-------------------------------------------------------------------------------
-- group: firmware
-------------------------------------------------------------------------------
dmmFirmwareVersion OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the firmware version of chassis management module 1."
::= { dmmFirmwareGroup 1 }
dmmFirmwareVersion2 OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the firmware version of chassis management module 2."
::= { dmmFirmwareGroup 2 }
-------------------------------------------------------------------------------
-- group: chassis status
-------------------------------------------------------------------------------
dmmGlobalSystemStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the overall chassis status
being monitored by the chassis management module."
::= { dmmStatusGroup 1 }
dmmIOMCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the IOM subsystem status
being monitored by the chassis management module."
::= { dmmStatusNowGroup 1 }
dmmRedCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Redundancy status
being monitored by the chassis management module."
::= { dmmStatusNowGroup 2 }
dmmPowerCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the power subsystem health status
being monitored by the chassis management module."
::= { dmmStatusNowGroup 3 }
dmmFanCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Fan subsystem health status
being monitored by the chassis management module."
::= { dmmStatusNowGroup 4 }
dmmBladeCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Blade subsystem health status
being monitored by the chassis management module."
::= { dmmStatusNowGroup 5 }
dmmTempCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the Temp Sensor subsystem health status
being monitored by the chassis management module."
::= { dmmStatusNowGroup 6 }
dmmMMCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the health status
being monitored by the chassis management module."
::= { dmmStatusNowGroup 7 }
dmmChassisFrontPanelAmbientTemperature OBJECT-TYPE
SYNTAX DellTemperatureReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the ambient temperature
reading (in degrees Celsius) for the chassis front panel module."
::= { dmmStatusNowGroup 8 }
-------------------------------------------------------------------------------
-- group: chassis power
-------------------------------------------------------------------------------
dmmPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF DmmPowerTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This object defines the power table."
::= { dmmChassisPowerGroup 1 }
dmmPowerTableEntry OBJECT-TYPE
SYNTAX DmmPowerTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This object defines the power table entry."
INDEX { dmmPowerChassisIndex }
::= { dmmPowerTable 1 }
dmmPSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF DmmPSUTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This object defines the PSU table."
::= { dmmChassisPowerGroup 2 }
dmmPSUTableEntry OBJECT-TYPE
SYNTAX DmmPSUTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "This object defines the PSU table entry."
INDEX { dmmPSUChassisIndex, dmmPSUIndex }
::= { dmmPSUTable 1 }
-------------------------------------------------------------------------------
-- table: power information
-------------------------------------------------------------------------------
dmmPowerChassisIndex OBJECT-TYPE
SYNTAX DellPowerIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the index
(one-based) of the associated chassis."
::= { dmmPowerTableEntry 1 }
dmmPowerIdlePower OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the power (in Watts) required by
the chassis infrastructure, plus the sum of the minimum power requirements
for all currently powered-on servers."
::= { dmmPowerTableEntry 2 }
dmmPowerKWhCumulative OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the cumulative chassis power
usage (in KWh) since last reset."
::= { dmmPowerTableEntry 3 }
dmmPowerKWhCumulativeTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the timestamp of the most recent
chassis power accumulator reset."
::= { dmmPowerTableEntry 4 }
dmmPowerWattsPeakUsage OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the chassis peak power
usage (in Watts) since last reset."
::= { dmmPowerTableEntry 5 }
dmmPowerWattsPeakTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the timestamp of the most recent
chassis peak power usage."
::= { dmmPowerTableEntry 6 }
dmmPowerWattsMinUsage OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the chassis mimimum power
usage (in Watts) since last reset."
::= { dmmPowerTableEntry 7 }
dmmPowerWattsMinTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the timestamp of the most recent
chassis minimum power usage."
::= { dmmPowerTableEntry 8 }
dmmPowerWattsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the instantaneous chassis power
usage (in Watts)."
::= { dmmPowerTableEntry 9 }
-------------------------------------------------------------------------------
-- table: PSU info
-------------------------------------------------------------------------------
dmmPSUChassisIndex OBJECT-TYPE
SYNTAX DellPowerIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the index
(one-based) of the associated chassis."
::= { dmmPSUTableEntry 1 }
dmmPSUIndex OBJECT-TYPE
SYNTAX DellPSUIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the index
(one-based) of the associated PSU."
::= { dmmPSUTableEntry 2 }
dmmPSULocation OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the location
of the PSU."
::= { dmmPSUTableEntry 3 }
dmmPSUState OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the enabled state of
of the PSU."
::= { dmmPSUTableEntry 4 }
dmmPSUType OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the type
of the PSU."
::= { dmmPSUTableEntry 5 }
dmmPSUCapacity OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the capacity in watts
of the PSU."
::= { dmmPSUTableEntry 6 }
dmmPSUVoltage OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the input voltage
of the PSU."
::= { dmmPSUTableEntry 7 }
dmmPSUCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "This attribute defines the current status
of the PSU."
::= { dmmPSUTableEntry 8 }
-------------------------------------------------------------------------------
-- group: Chassis Alerts 2
-------------------------------------------------------------------------------
dmmCA2MessageID OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Message ID of the alert."
::= { dmmChassisAlert2Variables 1 }
dmmCA2Message OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Message describing the alert."
::= { dmmChassisAlert2Variables 2 }
dmmCA2MessageArgs OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Concatenated set of strings representing any message arguments
that were used to construct the alert message. Each message
argument string is enclosed in double quotes, and there is a
comma after the ending double quote of each message argument
string, except the last one. Any double quotes found within a
message argument string were preprocessed and changed to single
quotes."
::= { dmmChassisAlert2Variables 3 }
dmmCA2AlertStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of the alert."
::= { dmmChassisAlert2Variables 4 }
dmmCA2FQDD OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..512))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Fully qualified device descriptor of device causing the alert."
::= { dmmChassisAlert2Variables 5 }
-------------------------------------------------------------------------------
-- group: Generic Alerts
-------------------------------------------------------------------------------
dmmDeviceServiceTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Service tag of the device."
::= { dmmGenericAlertVariables 1 }
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Amperage Probe Traps
--
-- Category: System/1
-- Subcategory: AMP/16
------------------------------------------------------------------------------
alert2AmperageProbeNormal TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag }
DESCRIPTION
"Current sensor reading is within range."
--#TYPE "System: Amperage Normal"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2179
alert2AmperageProbeWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Current sensor has detected a warning value."
--#TYPE "System: Amperage Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2178
alert2AmperageProbeFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Current sensor has detected a failure value."
--#TYPE "System: Amperage Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2177
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Battery Traps
--
-- Category: System/1
-- Subcategory: BAT/22
------------------------------------------------------------------------------
alert2BatteryNormal TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Battery state has returned to normal;
or battery presence had been detected."
--#TYPE "System: Battery Normal"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2227
alert2BatteryWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Battery is low."
--#TYPE "System: Battery Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2226
alert2BatteryFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Battery has failed or battery is absent."
--#TYPE "System: Battery Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2225
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Cable Traps
--
-- Category: System/1
-- Subcategory: CBL/43
------------------------------------------------------------------------------
alert2CableFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Cable failure."
--#TYPE "System: Cable Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2393
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Traps
--
-- Category: System/1
-- Subcategory: MM/62
------------------------------------------------------------------------------
alert2CMCWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Chassis Management Module detected a warning."
--#TYPE "System: Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2546
alert2CMCFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Chassis Management Module detected an error."
--#TYPE "System: Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2545
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Fan Traps
--
-- Category: System/1
-- Subcategory: FAN/13
------------------------------------------------------------------------------
alert2FanInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Fan information."
--#TYPE "System: Fan Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2155
alert2FanWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Fan warning."
--#TYPE "System: Fan Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2154
alert2FanFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Fan failure."
--#TYPE "System: Fan Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2153
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Hardware Configuration Traps
--
-- Category: System/1
-- Subcategory: HWC/35
------------------------------------------------------------------------------
alert2HardwareConfigurationInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Hardware configuration information."
--#TYPE "System: Hardware Configuration Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2331
alert2HardwareConfigurationWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Hardware configuration warning."
--#TYPE "System: Hardware Configuration Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2330
alert2HardwareConfigurationFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Hardware configuration failure or critical event."
--#TYPE "System: Hardware Configuration Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2329
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: IO Virtualization Traps
--
-- Category: System/1
-- Subcategory: IOV/63
------------------------------------------------------------------------------
alert2IOVirtualizationInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"IO Virtualization information."
--#TYPE "System: IO Virtualization Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2555
alert2IOVirtualizationWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"IO Virtualization warning."
--#TYPE "System: IO Virtualization Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2554
alert2IOVirtualizationFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"IO Virtualization failure or critical event."
--#TYPE "System: IO Virtualization Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2553
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Link Status Traps
--
-- Category: System/1
-- Subcategory: LNK/25
------------------------------------------------------------------------------
alert2LinkStatusInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Link status information."
--#TYPE "System: Link Status Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2251
alert2LinkStatusWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Link status warning."
--#TYPE "System: Link Status Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2250
alert2LinkStatusFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Link status failure or critical event."
--#TYPE "System: Link Status Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2249
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Power Supply Traps
--
-- Category: System/1
-- Subcategory: PSU/17
------------------------------------------------------------------------------
alert2PowerSupplyNormal TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power supply has returned to normal."
--#TYPE "System: Power Supply Normal"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2187
alert2PowerSupplyWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power supply has detected a warning."
--#TYPE "System: Power Supply Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2186
alert2PowerSupplyFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power supply has detected a failure."
--#TYPE "System: Power Supply Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2185
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Power Supply Absent Traps
--
-- Category: System/1
-- Subcategory: PSUA/52
------------------------------------------------------------------------------
alert2PowerSupplyAbsent TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power supply is absent."
--#TYPE "System: Power Supply Absent"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2465
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Power Usage Traps
--
-- Category: System/1
-- Subcategory: PWR/28
------------------------------------------------------------------------------
alert2PowerUsageInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power usage information."
--#TYPE "System: Power Usage Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2275
alert2PowerUsageWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power usage warning."
--#TYPE "System: Power Usage Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2274
alert2PowerUsageFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power usage failure."
--#TYPE "System: Power Usage Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2273
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Redundancy Traps
--
-- Category: System/1
-- Subcategory: RDU/53
------------------------------------------------------------------------------
alert2RedundancyInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Redundancy information."
--#TYPE "System: Redundancy Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2475
alert2RedundancyDegraded TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Redundancy is degraded."
--#TYPE "System: Redundancy Degraded"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2474
alert2RedundancyLost TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Redundancy is lost."
--#TYPE "System: Redundancy Lost"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2473
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Security Event Traps
--
-- Category: System/1
-- Subcategory: SEC/42
------------------------------------------------------------------------------
alert2SecurityInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Security information."
--#TYPE "System: Security Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2387
alert2SecurityWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Security warning."
--#TYPE "System: Security Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2386
alert2SecurityFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Security failure or critical event."
--#TYPE "System: Security Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2385
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: System Event Log Traps
--
-- Category: System/1
-- Subcategory: SEL/41
------------------------------------------------------------------------------
alert2SystemEventLogInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"System Event Log information."
--#TYPE "System: System Event Log Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2379
alert2SystemEventLogWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"System Event Log warning."
--#TYPE "System: System Event Log Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2378
alert2SystemEventLogFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"System Event Log failure or critical event."
--#TYPE "System: System Event Log Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2377
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Software Configuration Traps
--
-- Category: System/1
-- Subcategory: SWC/36
------------------------------------------------------------------------------
alert2SoftwareConfigurationInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Software configuration information."
--#TYPE "System: Software Configuration Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2339
alert2SoftwareConfigurationWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Software configuration warning."
--#TYPE "System: Software Configuration Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2338
alert2SoftwareConfigurationFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Software configuration failure."
--#TYPE "System: Software Configuration Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2337
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Temperature Probe Traps
--
-- Category: System/1
-- Subcategory: TMP/14
------------------------------------------------------------------------------
alert2TemperatureProbeNormal TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Temperature sensor value is within range."
--#TYPE "System: Temperature Normal"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2163
alert2TemperatureProbeWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Temperature sensor has detected a warning value."
--#TYPE "System: Temperature Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2162
alert2TemperatureProbeFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Temperature sensor has detected a failure value."
--#TYPE "System: Temperature Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2161
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Voltage Probe Traps
--
-- Category: System/1
-- Subcategory: VLT/15
------------------------------------------------------------------------------
alert2VoltageProbeNormal TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Voltage sensor reading is within range."
--#TYPE "System: Voltage Normal"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2171
alert2VoltageProbeWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Voltage sensor has detected a warning value."
--#TYPE "System: Voltage Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2170
alert2VoltageProbeFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Voltage sensor has detected a failure value."
--#TYPE "System: Voltage Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2169
-------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Battery Traps
--
-- Category: Storage/2
-- Subcategory: BAT/22
-------------------------------------------------------------------------------
alert2StorageBatteryInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Battery information."
--#TYPE "Storage: Battery Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4275
alert2StorageBatteryWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Battery warning."
--#TYPE "Storage: Battery Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4274
alert2StorageBatteryFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Battery failure."
--#TYPE "Storage: Battery Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4273
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Controller Traps
--
-- Category: Storage/2
-- Subcategory: CTL/29
------------------------------------------------------------------------------
alert2StorageControllerInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Controller information."
--#TYPE "Storage: Controller Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4331
alert2StorageControllerWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Controller warning."
--#TYPE "Storage: Controller Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4330
alert2StorageControllerFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Controller failure."
--#TYPE "Storage: Controller Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4329
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Enclosure Traps
--
-- Category: Storage/2
-- Subcategory: ENC/30
------------------------------------------------------------------------------
alert2StorageEnclosureInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Enclosure information."
--#TYPE "Storage: Enclosure Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4339
alert2StorageEnclosureWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Enclosure warning."
--#TYPE "Storage: Enclosure Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4338
alert2StorageEnclosureFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Enclosure failure."
--#TYPE "Storage: Enclosure Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4337
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Fan Traps
--
-- Category: Storage/2
-- Subcategory: FAN/13
------------------------------------------------------------------------------
alert2StorageFanInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Fan information."
--#TYPE "Storage: Fan Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4203
alert2StorageFanWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Fan warning."
--#TYPE "Storage: Fan Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4202
alert2StorageFanFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Fan failure."
--#TYPE "Storage: Fan Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4201
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Physical Disk Traps
--
-- Category: Storage/2
-- Subcategory: PDR/31
------------------------------------------------------------------------------
alert2StoragePhysicalDiskInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Physical disk information."
--#TYPE "Storage: Physical Disk Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4347
alert2StoragePhysicalDiskWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Physical disk warning."
--#TYPE "Storage: Physical Disk Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4346
alert2StoragePhysicalDiskFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Physical disk failure."
--#TYPE "Storage: Physical Disk Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4345
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Power Supply Traps
--
-- Category: Storage/2
-- Subcategory: PSU/17
------------------------------------------------------------------------------
alert2StoragePowerSupplyInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Power supply information."
--#TYPE "Storage: Power Supply Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4235
alert2StoragePowerSupplyWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Power supply warning."
--#TYPE "Storage: Power Supply Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4234
alert2StoragePowerSupplyFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Power supply failure."
--#TYPE "Storage: Power Supply Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4233
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Security Event Traps
--
-- Category: Storage/2
-- Subcategory: SEC/42
------------------------------------------------------------------------------
alert2StorageSecurityInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Security information."
--#TYPE "Storage: Security Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4435
alert2StorageSecurityWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Security warning."
--#TYPE "Storage: Security Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4434
alert2StorageSecurityFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Security failure or critical event."
--#TYPE "Storage: Security Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4433
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Storage Management Status Traps
--
-- Category: Storage/2
-- Subcategory: STOR/10
------------------------------------------------------------------------------
alert2StorageManagementInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Management information.
There is no global status change associated with this trap."
--#TYPE "Storage: Storage Management Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4179
alert2StorageManagementWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Management has detected a device independent warning
condition. There is no global status change associated with this
trap."
--#TYPE "Storage: Storage Management Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4178
alert2StorageManagementFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Management has detected a device independent error condition.
There is no global status change associated with this trap."
--#TYPE "Storage: Storage Management Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4177
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Temperature Probe Traps
--
-- Category: Storage/2
-- Subcategory: TMP/14
------------------------------------------------------------------------------
alert2StorageTemperatureProbeInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Temperature probe information."
--#TYPE "Storage: Temperature Probe Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4211
alert2StorageTemperatureProbeWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Temperature probe warning."
--#TYPE "Storage: Temperature Probe Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4210
alert2StorageTemperatureProbeFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Temperature probe failure."
--#TYPE "Storage: Temperature Probe Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4209
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Virtual Disk Traps
--
-- Category: Storage/2
-- Subcategory: VDR/32
------------------------------------------------------------------------------
alert2StorageVirtualDiskInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Virtual disk information."
--#TYPE "Storage: Virtual Disk Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4355
alert2StorageVirtualDiskWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Virtual disk warning."
--#TYPE "Storage: Virtual Disk Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4354
alert2StorageVirtualDiskFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Storage Virtual disk failure."
--#TYPE "Storage: Virtual Disk Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4353
------------------------------------------------------------------------------
-- Chassis Alerts 2: Updates: Software Change Traps
--
-- Category: Updates/3
-- Subcategory: SWU/21
------------------------------------------------------------------------------
alert2SoftwareChangeUpdateWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Software change update warning."
--#TYPE "Updates: Software Change Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 6314
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: Traps
--
-- Category: Audit/4
-- Subcategory: /62
------------------------------------------------------------------------------
alert2CMCAuditInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Chassis Management Module audit information."
--#TYPE "Audit: Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 8691
alert2CMCAuditWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Chassis Management Module audit warning."
--#TYPE "Audit: Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8690
alert2CMCAuditFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Chassis Management Module audit failure or critical event."
--#TYPE "Audit: Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8689
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: IO Virtualization Traps
--
-- Category: Audit/4
-- Subcategory: IOV/63
------------------------------------------------------------------------------
alert2IOVirtualizationAuditWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"IO Virtualization audit warning."
--#TYPE "Audit: IO Virtualization Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8698
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: License Traps
--
-- Category: Audit/4
-- Subcategory: LIC/40
------------------------------------------------------------------------------
alert2LicenseInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"License information."
--#TYPE "Audit: License Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 8515
alert2LicenseWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"License warning."
--#TYPE "Audit: License Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8514
alert2LicenseFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"License failure."
--#TYPE "Audit: License Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8513
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: PCI Device Traps
--
-- Category: Audit/4
-- Subcategory: PCI/46
------------------------------------------------------------------------------
alert2PCIDeviceAuditWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"PCI device audit warning."
--#TYPE "Audit: PCI Device Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8562
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: Power Supply Traps
--
-- Category: Audit/4
-- Subcategory: PSU/17
------------------------------------------------------------------------------
alert2PowerSupplyAuditWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power Supply audit warning."
--#TYPE "Audit: Power Supply Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8330
alert2PowerSupplyAuditFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power Supply audit failure or critical event."
--#TYPE "Audit: Power Supply Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8329
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: Power Usage Traps
--
-- Category: Audit/4
-- Subcategory: PWR/28
------------------------------------------------------------------------------
alert2PowerUsageAuditInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power usage audit information."
--#TYPE "Audit: Power Usage Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 8419
alert2PowerUsageAuditWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power usage audit warning."
--#TYPE "Audit: Power Usage Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8418
alert2PowerUsageAuditFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Power usage audit failure or critical event."
--#TYPE "Audit: Power Usage Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8417
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: Software Change Traps
--
-- Category: Audit/4
-- Subcategory: SWU/21
------------------------------------------------------------------------------
alert2SoftwareChangeAuditFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Software change audit failure or critical event."
--#TYPE "Audit: Software Change Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8361
------------------------------------------------------------------------------
-- Chassis Alerts 2: Configuration: IO Virtualization Traps
--
-- Category: Configuration/5
-- Subcategory: IOV/63
------------------------------------------------------------------------------
alert2IOVConfigurationInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"IO Virtualization configuration information."
--#TYPE "Configuration: IO Virtualization Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 10747
alert2IOVConfigurationWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"IO Virtualization configuration warning."
--#TYPE "Configuration: IO Virtualization Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 10746
------------------------------------------------------------------------------
-- Chassis Alerts 2: Configuration: PCI Device Traps
--
-- Category: Configuration/5
-- Subcategory: PCI/46
------------------------------------------------------------------------------
alert2PCIDeviceConfigurationInformation TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"PCI device configuration information."
--#TYPE "Configuration: PCI Device Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 10611
------------------------------------------------------------------------------
-- Chassis Alerts 2: Configuration: Software Configuration Traps
--
-- Category: Configuration/5
-- Subcategory: SWC/36
------------------------------------------------------------------------------
alert2SWCConfigurationWarning TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Software configuration warning."
--#TYPE "Configuration: Software Configuration Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 10530
alert2SWCConfigurationFailure TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Software configuration failure."
--#TYPE "Configuration: Software Configuration Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s"
--#ARGUMENTS {0, 1, 3, 4, 6, 5}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 10529
------------------------------------------------------------------------------
-- Chassis Alerts 2: Configuration: Test Traps
--
-- Category: Configuration/5
-- Subcategory: TST/19
------------------------------------------------------------------------------
alert2CMCTestTrap TRAP-TYPE
ENTERPRISE dmmChassisAlert2Group
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmCA2FQDD,
dmmProductChassisName,
dmmChassisServiceTag}
DESCRIPTION
"Test trap generated in response to a user request."
--#TYPE "Configuration: Test Trap"
--#SEVERITY INFORMATIONAL
--#SUMMARY "%s"
--#ARGUMENTS {1}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 10395
------------------------------------------------------------------------------
-- Alert 1: Internal: Internal MM Traps
--
-- Category: Internal/1
-- Subcategory: Internal/1
------------------------------------------------------------------------------
alertGenericCritical TRAP-TYPE
ENTERPRISE dmmGenericAlertGroup
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmDeviceServiceTag
}
DESCRIPTION
"MM generic critical system alert."
--#TYPE "Internal: MM System Alert"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d "
--#ARGUMENTS {0, 1, 3}
--#CATEGORY "Internal Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 100
------------------------------------------------------------------------------
-- MM Alert 2: Internal: Internal MM Traps
--
-- Category: Internal/1
-- Subcategory: Internal/2
------------------------------------------------------------------------------
alertGenericWarning TRAP-TYPE
ENTERPRISE dmmGenericAlertGroup
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmDeviceServiceTag
}
DESCRIPTION
"MM generic warning system alert."
--#TYPE "Internal: MM System Alert"
--#SEVERITY WARNING
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d "
--#ARGUMENTS {0, 1, 3}
--#CATEGORY "Internal Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 200
------------------------------------------------------------------------------
-- MM Alert 3: Internal: Internal MM Traps
--
-- Category: Internal/1
-- Subcategory: Internal/3
------------------------------------------------------------------------------
alertGenericNormal TRAP-TYPE
ENTERPRISE dmmGenericAlertGroup
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmDeviceServiceTag
}
DESCRIPTION
"MM generic normal system alert."
--#TYPE "Internal: MM System Alert"
--#SEVERITY NORMAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d "
--#ARGUMENTS {0, 1, 3}
--#CATEGORY "Internal Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 300
------------------------------------------------------------------------------
-- MM Alert 4: Internal: Internal MM Traps
--
-- Category: Internal/1
-- Subcategory: Internal/4
------------------------------------------------------------------------------
alertGenericInformational TRAP-TYPE
ENTERPRISE dmmGenericAlertGroup
VARIABLES { dmmCA2MessageID,
dmmCA2Message,
dmmCA2MessageArgs,
dmmCA2AlertStatus,
dmmDeviceServiceTag
}
DESCRIPTION
"MM generic information system alert."
--#TYPE "Internal: MM System Alert"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d "
--#ARGUMENTS {0, 1, 3}
--#CATEGORY "Internal Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 400
------------------------------------------------------------------------------
-- MM Alert 5: Internal: Internal MM Traps
--
-- Category: Internal/1
-- Subcategory: Internal/5
------------------------------------------------------------------------------
alertGenericTestTrapEvent TRAP-TYPE
ENTERPRISE dmmGenericAlertGroup
VARIABLES { dmmCA2Message
}
DESCRIPTION
"MM Generated a test trap event in response to a user request."
--#TYPE "Internal: Dell MM Test TRAP Event"
--#SEVERITY INFORMATIONAL
--#SUMMARY "%s"
--#ARGUMENTS {0}
--#CATEGORY "Status Events"
::= 500
END