-- -- Dell Management Module MIB -- Management Information Base -- -- This MIB is intended for use with the OpenManage Enterprise-Modular management software. -- -- Copyright (c) 2018 Dell Inc. -- -- Last Changed Revision: 1 -- Last Changed Date: 2018-06-13 13:44:00 -0500 (Wed, 13 Jun 2018) -- DELL-MM-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString FROM RFC1213-MIB; -- text convention ------------------------------------------------------------------------ ------------------------------------------------------------------------------- -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having -- SIZE (0..1023) ------------------------------------------------------------------------------- DellString ::= DisplayString (SIZE (0..1023)) DellMmType ::= INTEGER { other(1), -- the MM type is not one of the following unknown(2), -- the MM type is unknown mxMM(3) -- MX Chassis (MM) } DellStatus ::= INTEGER { other(1), -- the status of the object is not one of the following: unknown(2), -- the status of the object is unknown -- (not known or monitored) ok(3), -- the status of the object is ok nonCritical(4), -- the status of the object is warning, non-critical critical(5), -- the status of the object is critical (failure) nonRecoverable(6) -- the status of the object is non-recoverable (dead) } ------------------------------------------------------------------------------- -- DellPowerReading is a string representation of a floating point value, -- having exactly 3 digits of precision, and a maximum of 31 characters. -- -- DellChassisPowerIndexRange defines the possible chassis power instances -- in this MIB. -- -- DellPSUIndexRange defines the possible Power Supply Unit (PSU) -- instances, per chassis power instance, in this MIB. -- -- DellPSUCapable is an enumeration of PSU presence and/or monitoring -- capabilities. -- -- DellTemperatureReading is an integer value, expressed in degrees Celsius. ------------------------------------------------------------------------------- DellPowerReading ::= DisplayString (SIZE (0..32)) DellPowerIndexRange ::= INTEGER (1..1) DellPSUIndexRange ::= INTEGER (1..6) DellPSUCapable ::= INTEGER { absent(1), -- power supply is not present none(2), -- no power monitoring abilities basic(3) -- basic power monitoring abilities } DellTemperatureReading ::= INTEGER ------------------------------------------------------------------------------- -- DellTimestamp is defined in the displayable format: -- -- yyyymmddHHMMSS.uuuuuuDooo -- -- where yyyy is the year, mm is the month number, dd is the day of the month, -- HHMMSS are the hours, minutes and seconds, respectively, uuuuuu is the -- number of microseconds, D is the UTC offset direction, and ooo is the -- offset from UTC, in minutes. -- -- Note: D is a plus (+) sign if east of UTC, and a minus (-) if west of UTC. -- -- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT -- would be represented as: 19940525133015.000000-300 ------------------------------------------------------------------------------- DellTimestamp ::= DisplayString (SIZE (26)) -- MIB Objects and Tables -------------------------------------------------------- dell OBJECT IDENTIFIER ::= { enterprises 674 } server3 OBJECT IDENTIFIER ::= { dell 10892 } dmmOutOfBandGroup OBJECT IDENTIFIER ::= { server3 6 } dmmInformationGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 1 } dmmProductInfoGroup OBJECT IDENTIFIER ::= { dmmInformationGroup 1 } dmmFirmwareGroup OBJECT IDENTIFIER ::= { dmmInformationGroup 2 } dmmStatusGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 2 } dmmChassisStatusGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 3 } dmmStatusNowGroup OBJECT IDENTIFIER ::= { dmmChassisStatusGroup 1 } dmmChassisPowerGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 4 } DmmPowerTableEntry ::= SEQUENCE { dmmPowerChassisIndex DellPowerIndexRange, dmmPowerIdlePower DellPowerReading, dmmPowerKWhCumulative DellPowerReading, dmmPowerKWhCumulativeTime DellTimestamp, dmmPowerWattsPeakUsage DellPowerReading, dmmPowerWattsPeakTime DellTimestamp, dmmPowerWattsMinUsage DellPowerReading, dmmPowerWattsMinTime DellTimestamp, dmmPowerWattsReading DellPowerReading } DmmPSUTableEntry ::= SEQUENCE { dmmPSUChassisIndex DellPowerIndexRange, dmmPSUIndex DellPSUIndexRange, dmmPSULocation DellString, dmmPSUState DellString, dmmPSUType DellString, dmmPSUCapacity DellPowerReading, dmmPSUVoltage DellPowerReading, dmmPSUCurrStatus DellStatus } dmmChassisAlert2Group OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 5 } dmmChassisAlert2Variables OBJECT IDENTIFIER ::= { dmmChassisAlert2Group 1 } dmmGenericAlertGroup OBJECT IDENTIFIER ::= { dmmOutOfBandGroup 6 } dmmGenericAlertVariables OBJECT IDENTIFIER ::= { dmmGenericAlertGroup 1 } -- Variables and Traps ------------------------------------------------------------------------ ------------------------------------------------------------------------------- -- group: product information ------------------------------------------------------------------------------- dmmProductName OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the product name of a chassis management module." ::= { dmmProductInfoGroup 1 } dmmProductShortName OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the short product name of a chassis management module. " ::= { dmmProductInfoGroup 2 } dmmProductDescription OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the product description of a chassis management module. " ::= { dmmProductInfoGroup 3 } dmmProductManufacturer OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the product manufacturer of a chassis management module. " ::= { dmmProductInfoGroup 4 } dmmProductVersion OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the product version of a chassis management module. " ::= { dmmProductInfoGroup 5 } dmmChassisServiceTag OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Service Tag of the chassis. " ::= { dmmProductInfoGroup 6 } dmmProductURL OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the out-of-band UI URL of a chassis management module. " ::= { dmmProductInfoGroup 7 } dmmProductChassisAssetTag OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Asset Tag of the chassis. " ::= { dmmProductInfoGroup 8 } dmmProductChassisName OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the name of the chassis. " ::= { dmmProductInfoGroup 9 } dmmProductType OBJECT-TYPE SYNTAX DellMmType ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines type of a remote management module " ::= { dmmProductInfoGroup 10 } dmmProductChassisDataCenter OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Data Center locator of the chassis. " ::= { dmmProductInfoGroup 11 } dmmProductChassisAisle OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Aisle locator of the chassis. " ::= { dmmProductInfoGroup 12 } dmmProductChassisRack OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Rack locator of the chassis. " ::= { dmmProductInfoGroup 13 } dmmProductChassisRackSlot OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Rack Slot locator of the chassis. " ::= { dmmProductInfoGroup 14 } dmmProductChassisModel OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Model of the chassis." ::= { dmmProductInfoGroup 15 } dmmProductChassisExpressServiceCode OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Express Service Code of the chassis." ::= { dmmProductInfoGroup 16 } dmmProductChassisSystemID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the System ID of the chassis." ::= { dmmProductInfoGroup 17 } ------------------------------------------------------------------------------- -- group: firmware ------------------------------------------------------------------------------- dmmFirmwareVersion OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the firmware version of chassis management module 1." ::= { dmmFirmwareGroup 1 } dmmFirmwareVersion2 OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the firmware version of chassis management module 2." ::= { dmmFirmwareGroup 2 } ------------------------------------------------------------------------------- -- group: chassis status ------------------------------------------------------------------------------- dmmGlobalSystemStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the overall chassis status being monitored by the chassis management module." ::= { dmmStatusGroup 1 } dmmIOMCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the IOM subsystem status being monitored by the chassis management module." ::= { dmmStatusNowGroup 1 } dmmRedCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Redundancy status being monitored by the chassis management module." ::= { dmmStatusNowGroup 2 } dmmPowerCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the power subsystem health status being monitored by the chassis management module." ::= { dmmStatusNowGroup 3 } dmmFanCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Fan subsystem health status being monitored by the chassis management module." ::= { dmmStatusNowGroup 4 } dmmBladeCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Blade subsystem health status being monitored by the chassis management module." ::= { dmmStatusNowGroup 5 } dmmTempCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management module." ::= { dmmStatusNowGroup 6 } dmmMMCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the health status being monitored by the chassis management module." ::= { dmmStatusNowGroup 7 } dmmChassisFrontPanelAmbientTemperature OBJECT-TYPE SYNTAX DellTemperatureReading ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel module." ::= { dmmStatusNowGroup 8 } ------------------------------------------------------------------------------- -- group: chassis power ------------------------------------------------------------------------------- dmmPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF DmmPowerTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines the power table." ::= { dmmChassisPowerGroup 1 } dmmPowerTableEntry OBJECT-TYPE SYNTAX DmmPowerTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines the power table entry." INDEX { dmmPowerChassisIndex } ::= { dmmPowerTable 1 } dmmPSUTable OBJECT-TYPE SYNTAX SEQUENCE OF DmmPSUTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines the PSU table." ::= { dmmChassisPowerGroup 2 } dmmPSUTableEntry OBJECT-TYPE SYNTAX DmmPSUTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This object defines the PSU table entry." INDEX { dmmPSUChassisIndex, dmmPSUIndex } ::= { dmmPSUTable 1 } ------------------------------------------------------------------------------- -- table: power information ------------------------------------------------------------------------------- dmmPowerChassisIndex OBJECT-TYPE SYNTAX DellPowerIndexRange ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the index (one-based) of the associated chassis." ::= { dmmPowerTableEntry 1 } dmmPowerIdlePower OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers." ::= { dmmPowerTableEntry 2 } dmmPowerKWhCumulative OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the cumulative chassis power usage (in KWh) since last reset." ::= { dmmPowerTableEntry 3 } dmmPowerKWhCumulativeTime OBJECT-TYPE SYNTAX DellTimestamp ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the timestamp of the most recent chassis power accumulator reset." ::= { dmmPowerTableEntry 4 } dmmPowerWattsPeakUsage OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the chassis peak power usage (in Watts) since last reset." ::= { dmmPowerTableEntry 5 } dmmPowerWattsPeakTime OBJECT-TYPE SYNTAX DellTimestamp ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the timestamp of the most recent chassis peak power usage." ::= { dmmPowerTableEntry 6 } dmmPowerWattsMinUsage OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the chassis mimimum power usage (in Watts) since last reset." ::= { dmmPowerTableEntry 7 } dmmPowerWattsMinTime OBJECT-TYPE SYNTAX DellTimestamp ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the timestamp of the most recent chassis minimum power usage." ::= { dmmPowerTableEntry 8 } dmmPowerWattsReading OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the instantaneous chassis power usage (in Watts)." ::= { dmmPowerTableEntry 9 } ------------------------------------------------------------------------------- -- table: PSU info ------------------------------------------------------------------------------- dmmPSUChassisIndex OBJECT-TYPE SYNTAX DellPowerIndexRange ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the index (one-based) of the associated chassis." ::= { dmmPSUTableEntry 1 } dmmPSUIndex OBJECT-TYPE SYNTAX DellPSUIndexRange ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the index (one-based) of the associated PSU." ::= { dmmPSUTableEntry 2 } dmmPSULocation OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the location of the PSU." ::= { dmmPSUTableEntry 3 } dmmPSUState OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the enabled state of of the PSU." ::= { dmmPSUTableEntry 4 } dmmPSUType OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the type of the PSU." ::= { dmmPSUTableEntry 5 } dmmPSUCapacity OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the capacity in watts of the PSU." ::= { dmmPSUTableEntry 6 } dmmPSUVoltage OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the input voltage of the PSU." ::= { dmmPSUTableEntry 7 } dmmPSUCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "This attribute defines the current status of the PSU." ::= { dmmPSUTableEntry 8 } ------------------------------------------------------------------------------- -- group: Chassis Alerts 2 ------------------------------------------------------------------------------- dmmCA2MessageID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Message ID of the alert." ::= { dmmChassisAlert2Variables 1 } dmmCA2Message OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "Message describing the alert." ::= { dmmChassisAlert2Variables 2 } dmmCA2MessageArgs OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string were preprocessed and changed to single quotes." ::= { dmmChassisAlert2Variables 3 } dmmCA2AlertStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "Status of the alert." ::= { dmmChassisAlert2Variables 4 } dmmCA2FQDD OBJECT-TYPE SYNTAX DisplayString (SIZE (0..512)) ACCESS read-only STATUS mandatory DESCRIPTION "Fully qualified device descriptor of device causing the alert." ::= { dmmChassisAlert2Variables 5 } ------------------------------------------------------------------------------- -- group: Generic Alerts ------------------------------------------------------------------------------- dmmDeviceServiceTag OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "Service tag of the device." ::= { dmmGenericAlertVariables 1 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Amperage Probe Traps -- -- Category: System/1 -- Subcategory: AMP/16 ------------------------------------------------------------------------------ alert2AmperageProbeNormal TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag } DESCRIPTION "Current sensor reading is within range." --#TYPE "System: Amperage Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2179 alert2AmperageProbeWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Current sensor has detected a warning value." --#TYPE "System: Amperage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2178 alert2AmperageProbeFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Current sensor has detected a failure value." --#TYPE "System: Amperage Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2177 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Battery Traps -- -- Category: System/1 -- Subcategory: BAT/22 ------------------------------------------------------------------------------ alert2BatteryNormal TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Battery state has returned to normal; or battery presence had been detected." --#TYPE "System: Battery Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2227 alert2BatteryWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Battery is low." --#TYPE "System: Battery Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2226 alert2BatteryFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Battery has failed or battery is absent." --#TYPE "System: Battery Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2225 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Cable Traps -- -- Category: System/1 -- Subcategory: CBL/43 ------------------------------------------------------------------------------ alert2CableFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Cable failure." --#TYPE "System: Cable Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2393 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Traps -- -- Category: System/1 -- Subcategory: MM/62 ------------------------------------------------------------------------------ alert2CMCWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Chassis Management Module detected a warning." --#TYPE "System: Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2546 alert2CMCFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Chassis Management Module detected an error." --#TYPE "System: Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2545 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Fan Traps -- -- Category: System/1 -- Subcategory: FAN/13 ------------------------------------------------------------------------------ alert2FanInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Fan information." --#TYPE "System: Fan Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2155 alert2FanWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Fan warning." --#TYPE "System: Fan Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2154 alert2FanFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Fan failure." --#TYPE "System: Fan Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2153 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Hardware Configuration Traps -- -- Category: System/1 -- Subcategory: HWC/35 ------------------------------------------------------------------------------ alert2HardwareConfigurationInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Hardware configuration information." --#TYPE "System: Hardware Configuration Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2331 alert2HardwareConfigurationWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Hardware configuration warning." --#TYPE "System: Hardware Configuration Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2330 alert2HardwareConfigurationFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Hardware configuration failure or critical event." --#TYPE "System: Hardware Configuration Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2329 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: IO Virtualization Traps -- -- Category: System/1 -- Subcategory: IOV/63 ------------------------------------------------------------------------------ alert2IOVirtualizationInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "IO Virtualization information." --#TYPE "System: IO Virtualization Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2555 alert2IOVirtualizationWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "IO Virtualization warning." --#TYPE "System: IO Virtualization Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2554 alert2IOVirtualizationFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "IO Virtualization failure or critical event." --#TYPE "System: IO Virtualization Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2553 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Link Status Traps -- -- Category: System/1 -- Subcategory: LNK/25 ------------------------------------------------------------------------------ alert2LinkStatusInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Link status information." --#TYPE "System: Link Status Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2251 alert2LinkStatusWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Link status warning." --#TYPE "System: Link Status Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2250 alert2LinkStatusFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Link status failure or critical event." --#TYPE "System: Link Status Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2249 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Power Supply Traps -- -- Category: System/1 -- Subcategory: PSU/17 ------------------------------------------------------------------------------ alert2PowerSupplyNormal TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power supply has returned to normal." --#TYPE "System: Power Supply Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2187 alert2PowerSupplyWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power supply has detected a warning." --#TYPE "System: Power Supply Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2186 alert2PowerSupplyFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power supply has detected a failure." --#TYPE "System: Power Supply Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2185 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Power Supply Absent Traps -- -- Category: System/1 -- Subcategory: PSUA/52 ------------------------------------------------------------------------------ alert2PowerSupplyAbsent TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power supply is absent." --#TYPE "System: Power Supply Absent" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2465 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Power Usage Traps -- -- Category: System/1 -- Subcategory: PWR/28 ------------------------------------------------------------------------------ alert2PowerUsageInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power usage information." --#TYPE "System: Power Usage Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2275 alert2PowerUsageWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power usage warning." --#TYPE "System: Power Usage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2274 alert2PowerUsageFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power usage failure." --#TYPE "System: Power Usage Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2273 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Redundancy Traps -- -- Category: System/1 -- Subcategory: RDU/53 ------------------------------------------------------------------------------ alert2RedundancyInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Redundancy information." --#TYPE "System: Redundancy Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2475 alert2RedundancyDegraded TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Redundancy is degraded." --#TYPE "System: Redundancy Degraded" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2474 alert2RedundancyLost TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Redundancy is lost." --#TYPE "System: Redundancy Lost" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2473 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Security Event Traps -- -- Category: System/1 -- Subcategory: SEC/42 ------------------------------------------------------------------------------ alert2SecurityInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Security information." --#TYPE "System: Security Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2387 alert2SecurityWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Security warning." --#TYPE "System: Security Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2386 alert2SecurityFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Security failure or critical event." --#TYPE "System: Security Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2385 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: System Event Log Traps -- -- Category: System/1 -- Subcategory: SEL/41 ------------------------------------------------------------------------------ alert2SystemEventLogInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "System Event Log information." --#TYPE "System: System Event Log Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2379 alert2SystemEventLogWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "System Event Log warning." --#TYPE "System: System Event Log Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2378 alert2SystemEventLogFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "System Event Log failure or critical event." --#TYPE "System: System Event Log Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2377 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Software Configuration Traps -- -- Category: System/1 -- Subcategory: SWC/36 ------------------------------------------------------------------------------ alert2SoftwareConfigurationInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Software configuration information." --#TYPE "System: Software Configuration Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2339 alert2SoftwareConfigurationWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Software configuration warning." --#TYPE "System: Software Configuration Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2338 alert2SoftwareConfigurationFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Software configuration failure." --#TYPE "System: Software Configuration Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2337 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Temperature Probe Traps -- -- Category: System/1 -- Subcategory: TMP/14 ------------------------------------------------------------------------------ alert2TemperatureProbeNormal TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Temperature sensor value is within range." --#TYPE "System: Temperature Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2163 alert2TemperatureProbeWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Temperature sensor has detected a warning value." --#TYPE "System: Temperature Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2162 alert2TemperatureProbeFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Temperature sensor has detected a failure value." --#TYPE "System: Temperature Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2161 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Voltage Probe Traps -- -- Category: System/1 -- Subcategory: VLT/15 ------------------------------------------------------------------------------ alert2VoltageProbeNormal TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Voltage sensor reading is within range." --#TYPE "System: Voltage Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2171 alert2VoltageProbeWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Voltage sensor has detected a warning value." --#TYPE "System: Voltage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2170 alert2VoltageProbeFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Voltage sensor has detected a failure value." --#TYPE "System: Voltage Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2169 ------------------------------------------------------------------------------- -- Chassis Alerts 2: Storage: Battery Traps -- -- Category: Storage/2 -- Subcategory: BAT/22 ------------------------------------------------------------------------------- alert2StorageBatteryInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Battery information." --#TYPE "Storage: Battery Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4275 alert2StorageBatteryWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Battery warning." --#TYPE "Storage: Battery Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4274 alert2StorageBatteryFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Battery failure." --#TYPE "Storage: Battery Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4273 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Controller Traps -- -- Category: Storage/2 -- Subcategory: CTL/29 ------------------------------------------------------------------------------ alert2StorageControllerInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Controller information." --#TYPE "Storage: Controller Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4331 alert2StorageControllerWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Controller warning." --#TYPE "Storage: Controller Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4330 alert2StorageControllerFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Controller failure." --#TYPE "Storage: Controller Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4329 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Enclosure Traps -- -- Category: Storage/2 -- Subcategory: ENC/30 ------------------------------------------------------------------------------ alert2StorageEnclosureInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Enclosure information." --#TYPE "Storage: Enclosure Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4339 alert2StorageEnclosureWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Enclosure warning." --#TYPE "Storage: Enclosure Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4338 alert2StorageEnclosureFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Enclosure failure." --#TYPE "Storage: Enclosure Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4337 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Fan Traps -- -- Category: Storage/2 -- Subcategory: FAN/13 ------------------------------------------------------------------------------ alert2StorageFanInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Fan information." --#TYPE "Storage: Fan Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4203 alert2StorageFanWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Fan warning." --#TYPE "Storage: Fan Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4202 alert2StorageFanFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Fan failure." --#TYPE "Storage: Fan Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4201 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Physical Disk Traps -- -- Category: Storage/2 -- Subcategory: PDR/31 ------------------------------------------------------------------------------ alert2StoragePhysicalDiskInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Physical disk information." --#TYPE "Storage: Physical Disk Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4347 alert2StoragePhysicalDiskWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Physical disk warning." --#TYPE "Storage: Physical Disk Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4346 alert2StoragePhysicalDiskFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Physical disk failure." --#TYPE "Storage: Physical Disk Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4345 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Power Supply Traps -- -- Category: Storage/2 -- Subcategory: PSU/17 ------------------------------------------------------------------------------ alert2StoragePowerSupplyInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Power supply information." --#TYPE "Storage: Power Supply Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4235 alert2StoragePowerSupplyWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Power supply warning." --#TYPE "Storage: Power Supply Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4234 alert2StoragePowerSupplyFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Power supply failure." --#TYPE "Storage: Power Supply Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4233 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Security Event Traps -- -- Category: Storage/2 -- Subcategory: SEC/42 ------------------------------------------------------------------------------ alert2StorageSecurityInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Security information." --#TYPE "Storage: Security Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4435 alert2StorageSecurityWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Security warning." --#TYPE "Storage: Security Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4434 alert2StorageSecurityFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Security failure or critical event." --#TYPE "Storage: Security Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4433 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Storage Management Status Traps -- -- Category: Storage/2 -- Subcategory: STOR/10 ------------------------------------------------------------------------------ alert2StorageManagementInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Management information. There is no global status change associated with this trap." --#TYPE "Storage: Storage Management Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4179 alert2StorageManagementWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Management has detected a device independent warning condition. There is no global status change associated with this trap." --#TYPE "Storage: Storage Management Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4178 alert2StorageManagementFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Management has detected a device independent error condition. There is no global status change associated with this trap." --#TYPE "Storage: Storage Management Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4177 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Temperature Probe Traps -- -- Category: Storage/2 -- Subcategory: TMP/14 ------------------------------------------------------------------------------ alert2StorageTemperatureProbeInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Temperature probe information." --#TYPE "Storage: Temperature Probe Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4211 alert2StorageTemperatureProbeWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Temperature probe warning." --#TYPE "Storage: Temperature Probe Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4210 alert2StorageTemperatureProbeFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Temperature probe failure." --#TYPE "Storage: Temperature Probe Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4209 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Virtual Disk Traps -- -- Category: Storage/2 -- Subcategory: VDR/32 ------------------------------------------------------------------------------ alert2StorageVirtualDiskInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Virtual disk information." --#TYPE "Storage: Virtual Disk Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4355 alert2StorageVirtualDiskWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Virtual disk warning." --#TYPE "Storage: Virtual Disk Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4354 alert2StorageVirtualDiskFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Storage Virtual disk failure." --#TYPE "Storage: Virtual Disk Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4353 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Updates: Software Change Traps -- -- Category: Updates/3 -- Subcategory: SWU/21 ------------------------------------------------------------------------------ alert2SoftwareChangeUpdateWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Software change update warning." --#TYPE "Updates: Software Change Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 6314 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: Traps -- -- Category: Audit/4 -- Subcategory: /62 ------------------------------------------------------------------------------ alert2CMCAuditInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Chassis Management Module audit information." --#TYPE "Audit: Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 8691 alert2CMCAuditWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Chassis Management Module audit warning." --#TYPE "Audit: Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8690 alert2CMCAuditFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Chassis Management Module audit failure or critical event." --#TYPE "Audit: Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8689 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: IO Virtualization Traps -- -- Category: Audit/4 -- Subcategory: IOV/63 ------------------------------------------------------------------------------ alert2IOVirtualizationAuditWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "IO Virtualization audit warning." --#TYPE "Audit: IO Virtualization Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8698 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: License Traps -- -- Category: Audit/4 -- Subcategory: LIC/40 ------------------------------------------------------------------------------ alert2LicenseInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "License information." --#TYPE "Audit: License Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 8515 alert2LicenseWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "License warning." --#TYPE "Audit: License Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8514 alert2LicenseFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "License failure." --#TYPE "Audit: License Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8513 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: PCI Device Traps -- -- Category: Audit/4 -- Subcategory: PCI/46 ------------------------------------------------------------------------------ alert2PCIDeviceAuditWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "PCI device audit warning." --#TYPE "Audit: PCI Device Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8562 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: Power Supply Traps -- -- Category: Audit/4 -- Subcategory: PSU/17 ------------------------------------------------------------------------------ alert2PowerSupplyAuditWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power Supply audit warning." --#TYPE "Audit: Power Supply Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8330 alert2PowerSupplyAuditFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power Supply audit failure or critical event." --#TYPE "Audit: Power Supply Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8329 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: Power Usage Traps -- -- Category: Audit/4 -- Subcategory: PWR/28 ------------------------------------------------------------------------------ alert2PowerUsageAuditInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power usage audit information." --#TYPE "Audit: Power Usage Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 8419 alert2PowerUsageAuditWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power usage audit warning." --#TYPE "Audit: Power Usage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8418 alert2PowerUsageAuditFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Power usage audit failure or critical event." --#TYPE "Audit: Power Usage Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8417 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: Software Change Traps -- -- Category: Audit/4 -- Subcategory: SWU/21 ------------------------------------------------------------------------------ alert2SoftwareChangeAuditFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Software change audit failure or critical event." --#TYPE "Audit: Software Change Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8361 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Configuration: IO Virtualization Traps -- -- Category: Configuration/5 -- Subcategory: IOV/63 ------------------------------------------------------------------------------ alert2IOVConfigurationInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "IO Virtualization configuration information." --#TYPE "Configuration: IO Virtualization Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 10747 alert2IOVConfigurationWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "IO Virtualization configuration warning." --#TYPE "Configuration: IO Virtualization Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 10746 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Configuration: PCI Device Traps -- -- Category: Configuration/5 -- Subcategory: PCI/46 ------------------------------------------------------------------------------ alert2PCIDeviceConfigurationInformation TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "PCI device configuration information." --#TYPE "Configuration: PCI Device Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 10611 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Configuration: Software Configuration Traps -- -- Category: Configuration/5 -- Subcategory: SWC/36 ------------------------------------------------------------------------------ alert2SWCConfigurationWarning TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Software configuration warning." --#TYPE "Configuration: Software Configuration Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 10530 alert2SWCConfigurationFailure TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Software configuration failure." --#TYPE "Configuration: Software Configuration Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s" --#ARGUMENTS {0, 1, 3, 4, 6, 5} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 10529 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Configuration: Test Traps -- -- Category: Configuration/5 -- Subcategory: TST/19 ------------------------------------------------------------------------------ alert2CMCTestTrap TRAP-TYPE ENTERPRISE dmmChassisAlert2Group VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmCA2FQDD, dmmProductChassisName, dmmChassisServiceTag} DESCRIPTION "Test trap generated in response to a user request." --#TYPE "Configuration: Test Trap" --#SEVERITY INFORMATIONAL --#SUMMARY "%s" --#ARGUMENTS {1} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 10395 ------------------------------------------------------------------------------ -- Alert 1: Internal: Internal MM Traps -- -- Category: Internal/1 -- Subcategory: Internal/1 ------------------------------------------------------------------------------ alertGenericCritical TRAP-TYPE ENTERPRISE dmmGenericAlertGroup VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmDeviceServiceTag } DESCRIPTION "MM generic critical system alert." --#TYPE "Internal: MM System Alert" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d " --#ARGUMENTS {0, 1, 3} --#CATEGORY "Internal Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 100 ------------------------------------------------------------------------------ -- MM Alert 2: Internal: Internal MM Traps -- -- Category: Internal/1 -- Subcategory: Internal/2 ------------------------------------------------------------------------------ alertGenericWarning TRAP-TYPE ENTERPRISE dmmGenericAlertGroup VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmDeviceServiceTag } DESCRIPTION "MM generic warning system alert." --#TYPE "Internal: MM System Alert" --#SEVERITY WARNING --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d " --#ARGUMENTS {0, 1, 3} --#CATEGORY "Internal Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 200 ------------------------------------------------------------------------------ -- MM Alert 3: Internal: Internal MM Traps -- -- Category: Internal/1 -- Subcategory: Internal/3 ------------------------------------------------------------------------------ alertGenericNormal TRAP-TYPE ENTERPRISE dmmGenericAlertGroup VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmDeviceServiceTag } DESCRIPTION "MM generic normal system alert." --#TYPE "Internal: MM System Alert" --#SEVERITY NORMAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d " --#ARGUMENTS {0, 1, 3} --#CATEGORY "Internal Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 300 ------------------------------------------------------------------------------ -- MM Alert 4: Internal: Internal MM Traps -- -- Category: Internal/1 -- Subcategory: Internal/4 ------------------------------------------------------------------------------ alertGenericInformational TRAP-TYPE ENTERPRISE dmmGenericAlertGroup VARIABLES { dmmCA2MessageID, dmmCA2Message, dmmCA2MessageArgs, dmmCA2AlertStatus, dmmDeviceServiceTag } DESCRIPTION "MM generic information system alert." --#TYPE "Internal: MM System Alert" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d " --#ARGUMENTS {0, 1, 3} --#CATEGORY "Internal Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 400 ------------------------------------------------------------------------------ -- MM Alert 5: Internal: Internal MM Traps -- -- Category: Internal/1 -- Subcategory: Internal/5 ------------------------------------------------------------------------------ alertGenericTestTrapEvent TRAP-TYPE ENTERPRISE dmmGenericAlertGroup VARIABLES { dmmCA2Message } DESCRIPTION "MM Generated a test trap event in response to a user request." --#TYPE "Internal: Dell MM Test TRAP Event" --#SEVERITY INFORMATIONAL --#SUMMARY "%s" --#ARGUMENTS {0} --#CATEGORY "Status Events" ::= 500 END