1248 lines
38 KiB
Plaintext

-- DES-2218 SWITCH HUB MIB V0.03 08/15/97
DES2218-MIB
DEFINITIONS ::= BEGIN
IMPORTS
enterprises, IpAddress,
TimeTicks,Counter
FROM RFC1155-SMI
DisplayString, PhysAddress
FROM RFC1213-MIB
TRAP-TYPE
FROM RFC-1215
OBJECT-TYPE
FROM RFC-1212;
-- OwnerString ::= DisplayString
-- This data type is used to model an administratively
-- assigned name of the owner of a resource. This
-- information is taken from the NVT ASCII character set.
-- It is suggested that this name contain one or more
-- of the following:
-- IP address, management station name, network manager's
-- name, location, or phone number.
-- SIZE (0..xx)
dlink OBJECT IDENTIFIER ::= { enterprises 171 }
dlink-products OBJECT IDENTIFIER ::= { dlink 10 }
dlink-Des2218Prod OBJECT IDENTIFIER ::= { dlink-products 7 }
dlink-Des2218ProdId OBJECT IDENTIFIER ::= { dlink-Des2218Prod 1 }
des2218SwHub OBJECT IDENTIFIER ::= { dlink-Des2218Prod 2 }
dlink-mgmt OBJECT IDENTIFIER ::= { dlink 11 }
agentConfigInfo OBJECT IDENTIFIER ::= { dlink-mgmt 1 }
des2218series OBJECT IDENTIFIER ::= { dlink-mgmt 7 }
-- agentBasicInfo
agentBasicInfo OBJECT IDENTIFIER ::= { agentConfigInfo 1 }
agentRuntimeSwVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a textual description of the runtime software version
and revision. If the version number is one and revision number is
zero agentRuntimeSwVersion would be 'Ver. 1.0'"
::= { agentBasicInfo 1 }
agentPromFwVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a textual description of the agent PROM firmware version
and revision. If the version number is one and revision number is
zero agentPromFwVersion would be 'Ver. 1.0'"
::= { agentBasicInfo 2 }
agentHwRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a textual description of the hardware revision.
The display string should look like 'Rev. A1'"
::= { agentBasicInfo 3 }
agentMgmtProtocolCapability OBJECT-TYPE
SYNTAX INTEGER {
other(1),
snmp-ip(2),
snmp-ipx(3),
snmp-ip-ipx(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The network management protocol(s) supported by this agent."
::= { agentBasicInfo 4 }
-- agentMibcapabilityTable
agentMibCapabilityTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentMibCapabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of MIB capability entries supported by this agent."
::= { agentBasicInfo 5 }
agentMibCapabilityEntry OBJECT-TYPE
SYNTAX AgentMibCapabilityEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A MIB capability entry contains objects describing a particular MIB
supported by this agent."
INDEX { agentMibCapabilityIndex }
::= { agentMibCapabilityTable 1 }
AgentMibCapabilityEntry ::= SEQUENCE {
agentMibCapabilityIndex
INTEGER,
agentMibCapabilityDescr
DisplayString,
agentMibCapabilityVersion
INTEGER,
agentMibCapabilityType
INTEGER
}
agentMibCapabilityIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A list of agentMibCapabilityDescr entries."
::= { agentMibCapabilityEntry 1 }
agentMibCapabilityDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the MIB supported by the agent."
::= { agentMibCapabilityEntry 2 }
agentMibCapabilityVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the MIB specified in this entry."
::= { agentMibCapabilityEntry 3 }
agentMibCapabilityType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
standard(2),
proprietary(3),
experiment(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the MIB specified in this entry."
::= { agentMibCapabilityEntry 4 }
-- agentMgmtRole OBJECT-TYPE
-- SYNTAX INTEGER {
-- other(1),
-- primary-master(2),
-- backup-master(3)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "The role of this agent within this particular hub stack"
-- ::= { agentBasicInfo 6 }
-- agentBasicConfig
agentBasicConfig OBJECT IDENTIFIER ::= { agentConfigInfo 2 }
agentSwUpdateMode OBJECT-TYPE
SYNTAX INTEGER {
other(1),
network-load(2),
out-of-band-load(3)
}
ACCESS read-write
STATUS
mandatory
DESCRIPTION
"The download media used by the system to download the
runtime software."
::= { agentBasicConfig 1 }
agentSwUpdateCtrl OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Current status of software download control. The setting
is effective the next time you reset or power on the hub."
::= { agentBasicConfig 2 }
agentBootFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of the file to be downloaded from the TFTP server when
software update is enabled."
::= { agentBasicConfig 3 }
agentSystemReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2),
no-reset(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the agent system reset state.
Setting this object to no-reset(3) has no effect.
Setting this object to reset(2) will reset the agent.
The agent always returns no-reset(3) when this object is read."
::= { agentBasicConfig 4 }
agentRs232PortConfig OBJECT-TYPE
SYNTAX INTEGER {
other(1),
console(2),
out-of-band(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current setting of RS-232C port.
The RS-232C port can be configured as the console port or
used for out-of-band connection."
::= { agentBasicConfig 5 }
agentOutOfBandBaudRateConfig OBJECT-TYPE
SYNTAX INTEGER {
other(1),
baudRate-2400 (2),
baudRate-9600 (3),
baudRate-19200(4),
baudRate-38400(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The baud rate setting for out of band connection.
The baud rate for the console interface is always 9600."
::= { agentBasicConfig 6 }
agentOutOfBandDialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The dial out phone number for out of band to establish
a connection. This entry is used for reference only."
::= { agentBasicConfig 7 }
-- agentIpProtocolConfig
agentIpProtoConfig OBJECT IDENTIFIER ::= { agentConfigInfo 3 }
agentIpNumOfIf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of IP interfaces supported by this agent."
::= { agentIpProtoConfig 1 }
agentIpIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentIpIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of IP interface entries supported by the agent."
::= { agentIpProtoConfig 2 }
agentIpIfEntry OBJECT-TYPE
SYNTAX AgentIpIfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An agentIPIfEntry contains information about a particular
IP interface."
INDEX { agentIpIfIndex }
::= { agentIpIfTable 1 }
AgentIpIfEntry ::= SEQUENCE {
agentIpIfIndex
INTEGER,
agentIpIfAddress
IpAddress,
agentIpIfNetMask
IpAddress,
agentIpIfDefaultRouter
IpAddress,
agentIpIfMacAddr
PhysAddress,
agentIpIfType
INTEGER
}
agentIpIfIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object uniquely identifies the IP interface number
in agentIpIfTable.
This value should never greater than agentIpNumOfIf"
::= { agentIpIfEntry 1 }
agentIpIfAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the interface."
::= { agentIpIfEntry 2 }
agentIpIfNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP net mask for this interface."
::= { agentIpIfEntry 3 }
agentIpIfDefaultRouter OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The default gateway for this IP interface."
::= { agentIpIfEntry 4 }
agentIpIfMacAddr OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC address of this IP interface.
For interfaces which do not have such an address
(e.g., a serial line), this object should contain
an octet string of zero length."
::= { agentIpIfEntry 5 }
agentIpIfType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
ethernet-csmacd(6),
slip(28) -- generic SLIP
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The physical layer interface of the IP interface."
::= { agentIpIfEntry 6 }
agentIpBootServerAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP Address of Boot Server."
::= { agentIpProtoConfig 3 }
agentIpBootProtocol OBJECT-TYPE
SYNTAX INTEGER {
other(1),
bootp-tftp(2),
tftp(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The software download protocol used for software update."
::= { agentIpProtoConfig 4 }
agentIpGetIpFromBootpServer OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates whether the agent get its system IP address
from BootP server at start up."
::= { agentIpProtoConfig 5 }
agentIpUnauthAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of an unauthorized SNMP packet."
::= { agentIpProtoConfig 6 }
agentIpUnauthComm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The community string of an unauthorized SNMP packet."
::= { agentIpProtoConfig 7 }
agentIpLastBootServerAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last IP address used as Boot server IP address."
::= { agentIpProtoConfig 8 }
agentIpLastIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last IP address used as the agent system IP address."
::= { agentIpProtoConfig 9 }
-- agentIptrapMangerTable
agentIpTrapManagerTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentIpTrapManagerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of trap manager entries to which to send SNMP traps ."
::= { agentIpProtoConfig 10 }
agentIpTrapManagerEntry OBJECT-TYPE
SYNTAX AgentIpTrapManagerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry contains the particular trap manager settings."
INDEX { agentIpTrapManagerIpAddr }
::= { agentIpTrapManagerTable 1 }
AgentIpTrapManagerEntry ::= SEQUENCE {
agentIpTrapManagerIpAddr
IpAddress,
agentIpTrapManagerComm
DisplayString,
agentIpTrapManagerStatus
INTEGER
}
agentIpTrapManagerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address to receive SNMP traps from this device."
::= { agentIpTrapManagerEntry 1 }
agentIpTrapManagerComm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The community string of the SNMP trap packet sent to
the trap manager."
::= { agentIpTrapManagerEntry 2 }
agentIpTrapManagerStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates whether or not the trap should be send to this
trap manager."
::= { agentIpTrapManagerEntry 3 }
des2218MIB OBJECT IDENTIFIER ::= { des2218series 1 }
swDevicePackage OBJECT IDENTIFIER ::= { des2218MIB 1 }
swPortPackage OBJECT IDENTIFIER ::= { des2218MIB 2 }
swDeviceInfo OBJECT IDENTIFIER ::= { swDevicePackage 1 }
swDevInfoTotalNumOfPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports within this switch hub. This value
is the sum of the ports of each group within this
switch hub."
::= { swDeviceInfo 1 }
swDevInfoNumOfPortOnUse OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports in this switch hub connected to the
segment or end stations."
::= { swDeviceInfo 2 }
-- swDevInfoSerialNum OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "The serial number of this switch hub."
-- ::= { swDeviceInfo 3 }
swDevInfoDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of this switch hub."
::= { swDeviceInfo 3 }
-- swDevInfoRepeaterType OBJECT-TYPE
-- SYNTAX INTEGER {
-- other(1),
-- baseband-10-Mb(2),
-- baseband-100-Mb-class-I(3),
-- baseband-100-Mb-class-II(4)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "This objects indicates the CSMA/CD repeater type. The type
-- value matches the clause number of the standard that specifies
-- the particular repeater, with further numerical identification
-- for the repeater classes within the same clause."
-- ::= { swDeviceInfo 5 }
swDevInfoPortType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
portType-UTP(2),
portType-AUI(3),
portType-Fiber(4),
portType-BNC(5),
portType-Option-module-RAS(6),
portType-Option-module-100Bridge(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connector type of this port."
::= { swDeviceInfo 4 }
swDevInfoHwRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the hardware revision of
this switch bub."
::= { swDeviceInfo 5 }
swDevInfoSystemUpTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime at the time the switch
entered its current operational state. If the
current state was entered prior to the last re-
initialization, then this object contains a zero
value."
::= { swDeviceInfo 6 }
swDevInfoFrontPanelLedStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..127))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current status of front panel LED."
::= { swDeviceInfo 7 }
-- swDevInfoMdiSwitch OBJECT-TYPE
-- SYNTAX INTEGER {
-- other(1),
-- mdi(2),
-- mdi-x(3)
-- }
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "The current setting of the MDI switch."
-- ::= { swDeviceInfo 9 }
swDevInfoDramSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The DRAM size of the switch hub"
::= { swDeviceInfo 8 }
swDeviceCtl OBJECT IDENTIFIER ::= { swDevicePackage 2 }
swDevCtrlDisableLearningState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This Object indicate the switch hub wether or not learn any
new addresses from the Ethernet ports."
::= { swDeviceCtl 1 }
swDevCtrlReset OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2),
no-reset(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the switch hub reset state.
Setting this object to no-reset(3) has no effect.
Setting this object to reset(2) will reset the agent.
The agent always returns no-reset(3) when this object is read."
::= { swDeviceCtl 2 }
swDevCtrlSpanningTree OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This Object control the device to enable/disable spanning
tree algorithm in the system initilization or reset."
::= { swDeviceCtl 3 }
swPortInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of port information entries."
::= { swPortPackage 1 }
swPortInfoEntry OBJECT-TYPE
SYNTAX SwPortInfoEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry contains the port information, like porttype,
linkstatus..."
INDEX { swPortInfoGroupIndex,swPortInfoIndex }
::= { swPortInfoTable 1 }
SwPortInfoEntry ::= SEQUENCE {
swPortInfoGroupIndex
INTEGER,
swPortInfoIndex
INTEGER,
swPortInfoType
INTEGER,
swPortInfoPartitionStatus
INTEGER,
swPortInfoLinkStatus
INTEGER,
swPortInfoDuplexMode
INTEGER,
swPortInfoNegotiationStatus
INTEGER,
swPortInfoSpeedStatus
INTEGER
}
swPortInfoGroupIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the port within the group for
which this entry contains infomation."
::= { swPortInfoEntry 1 }
swPortInfoIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicate switch hub port number."
::= { swPortInfoEntry 2 }
swPortInfoType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
portType-UTP(2),
portType-AUI(3),
portType-Fiber(4),
portType-BNC(5),
portType-Option-module-RAS(6),
portType-Option-module-100Bridge(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connector type of this port."
::= { swPortInfoEntry 3 }
swPortInfoPartitionStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
no-partion(2),
partion(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This Object indicate the port partition status."
::= { swPortInfoEntry 4 }
swPortInfoLinkStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
link-pass(2),
link-fail(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This Object indicate the port link test status."
::= { swPortInfoEntry 5 }
swPortInfoDuplexMode OBJECT-TYPE
SYNTAX INTEGER {
other(1),
half(2),
full(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This Object indicate the port work in which duplex mode."
::= { swPortInfoEntry 6 }
swPortInfoNegotiationStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This Object indicate the port work in auto negotiation
enabled or disabled."
::= { swPortInfoEntry 7 }
swPortInfoSpeedStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
speed-10M(2),
speed-100M(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This Object indicate the port trasmit rate is in 10M bps
or 100M bps ."
::= { swPortInfoEntry 8 }
swPortCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwPortCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of port state control entries."
::= { swPortPackage 2 }
swPortCtrlEntry OBJECT-TYPE
SYNTAX SwPortCtrlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry control the port state, like filter broadcast,
linkstatus..."
INDEX { swPortCtrlGroupIndex,swPortCtrlIndex }
::= { swPortCtrlTable 1 }
SwPortCtrlEntry ::= SEQUENCE {
swPortCtrlGroupIndex
INTEGER,
swPortCtrlIndex
INTEGER,
swPortCtrlAdminState
INTEGER,
swPortCtrlDuplexState
INTEGER,
swPortCtrlLinkStatusAlarmState
INTEGER,
swPortCtrlFilterBcastState
INTEGER,
swPortCtrlForwardUnknowState
INTEGER,
swPortCtrlPartitionStatus
INTEGER,
swPortCtrlNegotiationStatus
INTEGER,
swPortCtrlSpeedStatus
INTEGER
}
swPortCtrlGroupIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the port within the group for
which this entry contains infomation."
::= { swPortCtrlEntry 1 }
swPortCtrlIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicate switch hub port number."
::= { swPortCtrlEntry 2 }
swPortCtrlAdminState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port control administration state."
::= { swPortCtrlEntry 3 }
swPortCtrlDuplexState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
half(2),
full(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicating the port work in half/full duplex mode."
::= { swPortCtrlEntry 4 }
swPortCtrlLinkStatusAlarmState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Depending on this object to determine wether send a trap or
not when link status change ."
::= { swPortCtrlEntry 5 }
swPortCtrlFilterBcastState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
forward(2),
discard(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port control filter broadcast to all port or discard."
::= { swPortCtrlEntry 6 }
swPortCtrlForwardUnknowState OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port control forward unknow packet state."
::= { swPortCtrlEntry 7 }
swPortCtrlPartitionStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Depending on this object determine to send a trap or not when
the port was partition."
::= { swPortCtrlEntry 8 }
swPortCtrlNegotiationStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
disabled(2),
enabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Depending on this object determine to enable NWAY or disable."
::= { swPortCtrlEntry 9 }
swPortCtrlSpeedStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
speed-10M(2),
speed-100M(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Depending on this object to determining this port transmit
rate is 10M bps or 100M bps."
::= { swPortCtrlEntry 10}
swPortCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwPortCounterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of port MIB statistic Counter entries."
::= { swPortPackage 3 }
swPortCounterEntry OBJECT-TYPE
SYNTAX SwPortCounterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry include all the port Counter which support by
DES3208, like Bytes received, Bytes Sent ..."
INDEX { swPortCounterGroupIndex,swPortCounterIndex }
::= { swPortCounterTable 1 }
SwPortCounterEntry ::= SEQUENCE {
swPortCounterGroupIndex
INTEGER,
swPortCounterIndex
INTEGER,
swPortBytesReceived
Counter,
swPortBytesSent
Counter,
swPortFramesReceived
Counter,
swPortFramesSent
Counter,
swPortTotalBytesReceived
Counter,
swPortTotalFramesReceived
Counter,
swPortBroadcastFramesReceived
Counter,
swPortMulticastFramesReceived
Counter,
swPortCRCError
Counter,
swPortOversizeFrames
Counter,
swPortFragments
Counter,
swPortJabber
Counter,
swPortCollision
Counter,
swPortLateCollision
Counter,
swPortFrames64Bytes
Counter,
swPortFrames65To127Bytes
Counter,
swPortFrames128To255Bytes
Counter,
swPortFrames256To511Bytes
Counter,
swPortFrames512To1023Bytes
Counter,
swPortFrames1024To1522Bytes
Counter,
swPortMACRxError
Counter
}
swPortCounterGroupIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the port within the group for
which this entry contains infomation."
::= { swPortCounterEntry 1 }
swPortCounterIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object indicate switch hub port number."
::= { swPortCounterEntry 2 }
swPortBytesReceived OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good bytes received. Local and dropped packets
increment the counter as well."
::= { swPortCounterEntry 3 }
swPortBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good bytes sent."
::= { swPortCounterEntry 4 }
swPortFramesReceived OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good frames received. Local and dropped packets
increment the counter as well."
::= { swPortCounterEntry 5 }
swPortFramesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good frames sent."
::= { swPortCounterEntry 6 }
swPortTotalBytesReceived OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes received(good and bad)."
::= { swPortCounterEntry 7 }
swPortTotalFramesReceived OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames bytes received(good and bad)."
::= { swPortCounterEntry 8 }
swPortBroadcastFramesReceived OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good broadcast frames received. Local and dropped
packets increment the counter as well."
::= { swPortCounterEntry 9 }
swPortMulticastFramesReceived OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good multicast frames received. Local and dropped
packets increment the counter as well."
::= { swPortCounterEntry 10 }
swPortCRCError OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames with valid packet length and CRC error or
misaligned(odd number of nibbles)
increment the counter as well."
::= { swPortCounterEntry 11 }
swPortOversizeFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good frames with length more than 1518 bytes (
or 1522 bytes for LongEn = 1)."
::= { swPortCounterEntry 12 }
swPortFragments OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good bytes received. Local and dropped packets
increment the counter as well."
::= { swPortCounterEntry 13 }
swPortJabber OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames with length more than 1518 bytes and with
CRC error or misaligned."
::= { swPortCounterEntry 14 }
swPortCollision OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Collisions"
::= { swPortCounterEntry 15 }
swPortLateCollision OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Late Collision(collision occurring later than
576th transmitted bit"
::= { swPortCounterEntry 16 }
swPortFrames64Bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good packets with length of 64 bytes "
::= { swPortCounterEntry 17 }
swPortFrames65To127Bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good packets with length between 65 to 127 bytes "
::= { swPortCounterEntry 18 }
swPortFrames128To255Bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good packets with length between 128 to 255 bytes "
::= { swPortCounterEntry 19 }
swPortFrames256To511Bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good packets with length between 256 to 511 bytes "
::= { swPortCounterEntry 20 }
swPortFrames512To1023Bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good packets with length between 512 to 1023 bytes "
::= { swPortCounterEntry 21 }
swPortFrames1024To1522Bytes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good packets with length between 1024 to 1522 bytes "
::= { swPortCounterEntry 22 }
swPortMACRxError OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames with RX MAC Error "
::= { swPortCounterEntry 23 }
-- swPortDroppedFrames OBJECT-TYPE
-- SYNTAX Counter
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "The number of dropped frames.Dropped packets are those which a
-- receive buffer could not be allocated."
-- ::= { swPortCounterEntry 24 }
-- link up/down Trap
linkChangeEvent TRAP-TYPE
ENTERPRISE dlink
VARIABLES {
swPortInfoIndex,
swPortInfoType,
swPortInfoPartitionStatus,
swPortInfoLinkStatus,
swPortInfoDuplexMode
}
DESCRIPTION
"The trap is sent whenever the link state of a port changes
from link up to link down or from link down to link up"
::= 1
portPartition TRAP-TYPE
ENTERPRISE dlink
VARIABLES {
swPortInfoIndex,
swPortInfoType,
swPortInfoPartitionStatus,
swPortInfoLinkStatus,
swPortInfoDuplexMode
}
DESCRIPTION
"The trap is sent whenever the port state enter the Partion
mode when more than 32 collisions occur while trasmitting."
::= 2