630 lines
22 KiB
Plaintext
630 lines
22 KiB
Plaintext
CUBRO-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Gauge32,
|
|
Integer32, enterprises FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC
|
|
OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF;
|
|
|
|
cubro-MIB MODULE-IDENTITY
|
|
LAST-UPDATED "201610180000Z"
|
|
ORGANIZATION "Cubro Acronet GsmbH"
|
|
CONTACT-INFO "none"
|
|
DESCRIPTION "none"
|
|
REVISION "201610180000Z"
|
|
DESCRIPTION "none"
|
|
::= { enterprises 32182 }
|
|
|
|
packetmasterEX OBJECT IDENTIFIER ::= { cubro-MIB 1 }
|
|
environment OBJECT IDENTIFIER ::= { packetmasterEX 1 }
|
|
psu OBJECT IDENTIFIER ::= { environment 1 }
|
|
temperature OBJECT IDENTIFIER ::= { environment 2 }
|
|
fan OBJECT IDENTIFIER ::= { environment 3 }
|
|
transceiver OBJECT IDENTIFIER ::= { environment 4 }
|
|
|
|
-- ENV
|
|
--- PSU
|
|
EXPSUIndex ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each PSU
|
|
in the managed system. It is recommended that
|
|
values are assigned contiguously starting from 1.
|
|
The value for each PSU must remain constant at
|
|
least from one reinitialization of the entity
|
|
to the next reinitialization."
|
|
SYNTAX Integer32 (0..2147483647)
|
|
|
|
psuNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of PSU units (regardless of their
|
|
current state) present on this system."
|
|
::= { psu 1 }
|
|
|
|
psuTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EXPSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of PSU entries. The number of entries
|
|
is given by the value of psuNumber."
|
|
::= { psu 2 }
|
|
|
|
psuEntry OBJECT-TYPE
|
|
SYNTAX EXPSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable
|
|
to a particular PSU."
|
|
INDEX { psuIndex }
|
|
::= { psuTable 1 }
|
|
|
|
EXPSUEntry ::=
|
|
SEQUENCE {
|
|
psuIndex EXPSUIndex,
|
|
psuPresent DisplayString,
|
|
psuPower DisplayString,
|
|
psuType DisplayString,
|
|
psuAlert DisplayString
|
|
}
|
|
|
|
psuIndex OBJECT-TYPE
|
|
SYNTAX EXPSUIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each
|
|
PSU. It is recommended that values are assigned
|
|
contiguously starting from 1. The value for each
|
|
PSU must remain constant at least from
|
|
one re-initialization of the entity to the next
|
|
re-initialization."
|
|
::= { psuEntry 1 }
|
|
|
|
psuPresent OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing information whether
|
|
the PSU is present or not. Can be either 'PRESENT'
|
|
or 'ABSENT'."
|
|
::= { psuEntry 2 }
|
|
|
|
psuPower OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing information about the
|
|
power state of the PSU. Can be either 'OK', 'FAIL'
|
|
or '-' (latter if the PSU is absent)."
|
|
::= { psuEntry 3 }
|
|
|
|
psuType OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing information about the
|
|
type of the PSU. Can be either 'AC', 'DC' or '-'
|
|
(if the PSU is absent or unplugged)."
|
|
::= { psuEntry 4 }
|
|
|
|
psuAlert OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing information if the
|
|
PSU is in an alert state. Can be either 'NO'
|
|
(everything is running fine) or 'ALERT' (power
|
|
failure)."
|
|
::= { psuEntry 5 }
|
|
|
|
--- TEMP
|
|
-- int index, int temp, int lower alarm, int high alarm, int critical limit, str position
|
|
|
|
|
|
EXTEMPIndex ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each
|
|
temperature sensor in the managed system. It is
|
|
recommended that values are assigned contiguously
|
|
starting from 1. The value for each temperature
|
|
sensor must remain constant at least from one
|
|
reinitialization of the entity to the next re-
|
|
initialization."
|
|
SYNTAX Integer32 (0..2147483647)
|
|
|
|
tempNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of temperature sensor units (regardless
|
|
of their current state) present on this system."
|
|
::= { temperature 1 }
|
|
|
|
tempTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EXTEMPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of temperature sensor entries. The number of
|
|
entries is given by the value of tempNumber."
|
|
::= { temperature 2 }
|
|
|
|
tempEntry OBJECT-TYPE
|
|
SYNTAX EXTEMPEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable
|
|
to a particular temperature sensor."
|
|
INDEX { tempIndex }
|
|
::= { tempTable 1 }
|
|
|
|
EXTEMPEntry ::=
|
|
SEQUENCE {
|
|
tempIndex EXTEMPIndex,
|
|
tempTemp Integer32,
|
|
tempLowerAlarm Integer32,
|
|
tempHighAlarm Integer32,
|
|
tempCriticalLimit Integer32,
|
|
tempPosition DisplayString
|
|
}
|
|
|
|
tempIndex OBJECT-TYPE
|
|
SYNTAX EXTEMPIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each
|
|
temperature sensor. It is recommended that values
|
|
are assigned contiguously starting from 1. The value
|
|
for each temperature sensor must remain constant at
|
|
least from one reinitialization of the entity to the next
|
|
reinitialization."
|
|
::= { tempEntry 1 }
|
|
|
|
tempTemp OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature reported by the temperature sensor
|
|
in degrees Celsius."
|
|
::= { tempEntry 2 }
|
|
|
|
tempLowerAlarm OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower alarm limit of the temperature sensor in degrees
|
|
Celsius."
|
|
::= { tempEntry 3 }
|
|
|
|
tempHighAlarm OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The high temperature alarm limit of the temperature sensor
|
|
in degrees Celsius."
|
|
::= { tempEntry 4 }
|
|
|
|
tempCriticalLimit OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The critical temperature alarm limit of the temperature sensor
|
|
in degrees Celsius."
|
|
::= { tempEntry 5 }
|
|
|
|
tempPosition OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing information about the
|
|
location of the temperature sensor in the device.
|
|
This value can be an empty string."
|
|
::= { tempEntry 6 }
|
|
|
|
--- FAN
|
|
-- int index, str status, str speedrate, str mode
|
|
|
|
EXFANIndex ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each fan unit
|
|
in the managed system. It is recommended that values
|
|
are assigned contiguously starting from 1. The value
|
|
for each fan unit must remain constant at least from
|
|
one reinitialization of the entity to the next
|
|
reinitialization."
|
|
SYNTAX Integer32 (0..2147483647)
|
|
|
|
fanNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of fan units (regardless of their
|
|
current state) present on this system."
|
|
::= { fan 1 }
|
|
|
|
fanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EXFANEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of fan unit entities. The number of entries
|
|
is given by the value of fanNumber."
|
|
::= { fan 2 }
|
|
|
|
fanEntry OBJECT-TYPE
|
|
SYNTAX EXFANEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable
|
|
to a particular fan unit."
|
|
INDEX { fanIndex }
|
|
::= { fanTable 1 }
|
|
|
|
EXFANEntry ::=
|
|
SEQUENCE {
|
|
fanIndex EXFANIndex,
|
|
fanStatus DisplayString,
|
|
fanSpeedRate Gauge32,
|
|
fanMode DisplayString
|
|
}
|
|
|
|
fanIndex OBJECT-TYPE
|
|
SYNTAX EXFANIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each
|
|
fan unit. It is recommended that values are assigned
|
|
contiguously starting from 1. The value for each
|
|
fan unit must remain constant at least from
|
|
one reinitialization of the entity to the next
|
|
reinitialization."
|
|
::= { fanEntry 1 }
|
|
|
|
fanStatus OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing information about the
|
|
fan unit's status."
|
|
::= { fanEntry 2 }
|
|
|
|
fanSpeedRate OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contains the speed rate of the fan in percent."
|
|
::= { fanEntry 3 }
|
|
|
|
fanMode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing information about the
|
|
fan's run mode."
|
|
::= { fanEntry 4 }
|
|
|
|
-- Transceiver
|
|
--- int.2 transceiverIndex,
|
|
--- int.2 transmitPower, int.2 transmitHighAlarm, int.2 transmitHighWarn, int.2 transmitLowWarn, int.2 transmitLowAlarm,
|
|
--- int.2 receivePower, int.2 receiveHighAlarm, int.2 receiveHighWarn, int.2 receiveLowWarn, int.2 receiveLowAlarm
|
|
|
|
EXTransceiverIndex ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d-1"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each
|
|
SFP/SFP+/QSFP/... module. The value is the
|
|
module's port number times 10 plus the subport-
|
|
number on split ports. So port 5 would be 50 and
|
|
port 42/3 would be 423. The value for each
|
|
module must remain constant at least from
|
|
one reinitialization of the entity to the next
|
|
reinitialization."
|
|
SYNTAX Integer32 (0..2147483647)
|
|
|
|
transceiverNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of SFP/SFP+/QSFP/... modules
|
|
(regardless of their current state) present
|
|
on this system."
|
|
::= { transceiver 1 }
|
|
|
|
transceiverTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EXTransceiverEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of SFP/SFP+/QSFP/... module entities.
|
|
The number of entries is given by the value
|
|
of fanNumber."
|
|
::= { transceiver 2 }
|
|
|
|
transceiverEntry OBJECT-TYPE
|
|
SYNTAX EXTransceiverEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable
|
|
to a particular SFP/SFP+/QSFP/... module."
|
|
INDEX { transIndex }
|
|
::= { transceiverTable 1 }
|
|
|
|
EXTransceiverEntry ::=
|
|
SEQUENCE {
|
|
transIndex EXTransceiverIndex,
|
|
transName DisplayString,
|
|
transDiagnosticImplemented INTEGER,
|
|
transOpticalTransmitPower DisplayString,
|
|
transOpticalTransmitHighAlarm DisplayString,
|
|
transOpticalTransmitHighWarn DisplayString,
|
|
transOpticalTransmitLowWarn DisplayString,
|
|
transOpticalTransmitLowAlarm DisplayString,
|
|
transOpticalReceivePower DisplayString,
|
|
transOpticalReceiveHighAlarm DisplayString,
|
|
transOpticalReceiveHighWarn DisplayString,
|
|
transOpticalReceiveLowWarn DisplayString,
|
|
transOpticalReceiveLowAlarm DisplayString
|
|
}
|
|
|
|
transIndex OBJECT-TYPE
|
|
SYNTAX EXTransceiverIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each
|
|
SFP/SFP+/QSFP/... module. The value is the
|
|
module's port number times 10 plus the subport-
|
|
number on split ports. So port 5 would be 50 and
|
|
port 42/3 would be 423. The value for each
|
|
module must remain constant at least from
|
|
one reinitialization of the entity to the next
|
|
reinitialization."
|
|
::= { transceiverEntry 1 }
|
|
|
|
transName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing the port name of the
|
|
SFP/SFP+/QSFP/... module."
|
|
::= { transceiverEntry 2 }
|
|
|
|
transDiagnosticImplemented OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
true(1),
|
|
false(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is true(1) if the SFP/SFP+/QSFP/... module
|
|
implements diagnostics or false(2) if not. If false(2),
|
|
all the following values are invalid."
|
|
::= { transceiverEntry 3 }
|
|
|
|
transOpticalTransmitPower OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value contains the optical transmission power
|
|
as a decimal stringified value with two decimal points.
|
|
Can also be 'nan' if the sensor does not report a valid
|
|
value."
|
|
::= { transceiverEntry 4 }
|
|
|
|
transOpticalTransmitHighAlarm OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value contains the optical transmission power's
|
|
high alarm value as a decimal stringified value with
|
|
two decimal points. Can also be 'nan' if the sensor
|
|
does not report a valid value."
|
|
::= { transceiverEntry 5 }
|
|
|
|
transOpticalTransmitHighWarn OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value contains the optical transmission power's
|
|
high warn value as a decimal stringified value with
|
|
two decimal points. Can also be 'nan' if the sensor
|
|
does not report a valid value."
|
|
::= { transceiverEntry 6 }
|
|
|
|
transOpticalTransmitLowWarn OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value contains the optical transmission power's
|
|
low warn value as a decimal stringified value with
|
|
two decimal points. Can also be 'nan' if the sensor
|
|
does not report a valid value."
|
|
::= { transceiverEntry 7 }
|
|
|
|
transOpticalTransmitLowAlarm OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value contains the optical transmission power's
|
|
low alarm value as a decimal stringified value with
|
|
two decimal points. Can also be 'nan' if the sensor
|
|
does not report a valid value."
|
|
::= { transceiverEntry 8 }
|
|
|
|
|
|
transOpticalReceivePower OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value contains the optical receive power
|
|
as a decimal stringified value with two decimal points.
|
|
Can also be 'nan' if the sensor does not report a valid
|
|
value."
|
|
::= { transceiverEntry 9 }
|
|
|
|
transOpticalReceiveHighAlarm OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value contains the optical receive power's
|
|
high alarm value as a decimal stringified value with
|
|
two decimal points. Can also be 'nan' if the sensor
|
|
does not report a valid value."
|
|
::= { transceiverEntry 10 }
|
|
|
|
transOpticalReceiveHighWarn OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value contains the optical receive power's
|
|
high warn value as a decimal stringified value with
|
|
two decimal points. Can also be 'nan' if the sensor
|
|
does not report a valid value."
|
|
::= { transceiverEntry 11 }
|
|
|
|
transOpticalReceiveLowWarn OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value contains the optical receive power's
|
|
low warn value as a decimal stringified value with
|
|
two decimal points. Can also be 'nan' if the sensor
|
|
does not report a valid value."
|
|
::= { transceiverEntry 12 }
|
|
|
|
transOpticalReceiveLowAlarm OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value contains the optical receive power's
|
|
low alarm value as a decimal stringified value with
|
|
two decimal points. Can also be 'nan' if the sensor
|
|
does not report a valid value."
|
|
::= { transceiverEntry 13 }
|
|
|
|
|
|
-- conformance information
|
|
|
|
envConformance OBJECT IDENTIFIER ::= { environment 10 }
|
|
envGroups OBJECT IDENTIFIER ::= { envConformance 1 }
|
|
envCompliances OBJECT IDENTIFIER ::= { envConformance 2 }
|
|
|
|
-- compliance statements
|
|
|
|
envCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for Packetmaster EX environment
|
|
sensors."
|
|
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { envTempGroup }
|
|
|
|
GROUP envPSUGroup
|
|
DESCRIPTION
|
|
"This group is not mandatory."
|
|
|
|
GROUP envTempGroup
|
|
DESCRIPTION
|
|
"This group is not mandatory."
|
|
|
|
GROUP envFanGroup
|
|
DESCRIPTION
|
|
"This group is mandatory for temperature
|
|
sensors in the device."
|
|
|
|
GROUP transmitterGroup
|
|
DESCRIPTION
|
|
"This group is not mandatory."
|
|
|
|
::= { envCompliances 1 }
|
|
|
|
-- units of conformance
|
|
envPSUGroup OBJECT-GROUP
|
|
OBJECTS { psuNumber, psuPresent, psuPower, psuType, psuAlert }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information on the
|
|
presence and status of PSU units."
|
|
::= { envGroups 1 }
|
|
|
|
envTempGroup OBJECT-GROUP
|
|
OBJECTS { tempNumber, tempTemp, tempLowerAlarm, tempHighAlarm, tempCriticalLimit, tempPosition }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information on the
|
|
status of temperature sensors."
|
|
::= { envGroups 2 }
|
|
|
|
envFanGroup OBJECT-GROUP
|
|
OBJECTS { fanNumber, fanStatus, fanSpeedRate, fanMode }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information on the
|
|
status of fan units."
|
|
::= { envGroups 3 }
|
|
|
|
transmitterGroup OBJECT-GROUP
|
|
OBJECTS { transceiverNumber,
|
|
transName,
|
|
transDiagnosticImplemented,
|
|
transOpticalTransmitPower,
|
|
transOpticalTransmitHighAlarm,
|
|
transOpticalTransmitHighWarn,
|
|
transOpticalTransmitLowWarn,
|
|
transOpticalTransmitLowAlarm,
|
|
transOpticalReceivePower,
|
|
transOpticalReceiveHighAlarm,
|
|
transOpticalReceiveHighWarn,
|
|
transOpticalReceiveLowWarn,
|
|
transOpticalReceiveLowAlarm
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information on the
|
|
status of SFPs."
|
|
::= { envGroups 4 }
|
|
END |