CUBRO-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Integer32, enterprises FROM SNMPv2-SMI TEXTUAL-CONVENTION, DisplayString FROM SNMPv2-TC OBJECT-GROUP, MODULE-COMPLIANCE FROM SNMPv2-CONF; cubro-MIB MODULE-IDENTITY LAST-UPDATED "201610180000Z" ORGANIZATION "Cubro Acronet GsmbH" CONTACT-INFO "none" DESCRIPTION "none" REVISION "201610180000Z" DESCRIPTION "none" ::= { enterprises 32182 } packetmasterEX OBJECT IDENTIFIER ::= { cubro-MIB 1 } environment OBJECT IDENTIFIER ::= { packetmasterEX 1 } psu OBJECT IDENTIFIER ::= { environment 1 } temperature OBJECT IDENTIFIER ::= { environment 2 } fan OBJECT IDENTIFIER ::= { environment 3 } transceiver OBJECT IDENTIFIER ::= { environment 4 } -- ENV --- PSU EXPSUIndex ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "A unique value, greater than zero, for each PSU in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each PSU must remain constant at least from one reinitialization of the entity to the next reinitialization." SYNTAX Integer32 (0..2147483647) psuNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of PSU units (regardless of their current state) present on this system." ::= { psu 1 } psuTable OBJECT-TYPE SYNTAX SEQUENCE OF EXPSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of PSU entries. The number of entries is given by the value of psuNumber." ::= { psu 2 } psuEntry OBJECT-TYPE SYNTAX EXPSUEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular PSU." INDEX { psuIndex } ::= { psuTable 1 } EXPSUEntry ::= SEQUENCE { psuIndex EXPSUIndex, psuPresent DisplayString, psuPower DisplayString, psuType DisplayString, psuAlert DisplayString } psuIndex OBJECT-TYPE SYNTAX EXPSUIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value, greater than zero, for each PSU. It is recommended that values are assigned contiguously starting from 1. The value for each PSU must remain constant at least from one re-initialization of the entity to the next re-initialization." ::= { psuEntry 1 } psuPresent OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing information whether the PSU is present or not. Can be either 'PRESENT' or 'ABSENT'." ::= { psuEntry 2 } psuPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing information about the power state of the PSU. Can be either 'OK', 'FAIL' or '-' (latter if the PSU is absent)." ::= { psuEntry 3 } psuType OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing information about the type of the PSU. Can be either 'AC', 'DC' or '-' (if the PSU is absent or unplugged)." ::= { psuEntry 4 } psuAlert OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing information if the PSU is in an alert state. Can be either 'NO' (everything is running fine) or 'ALERT' (power failure)." ::= { psuEntry 5 } --- TEMP -- int index, int temp, int lower alarm, int high alarm, int critical limit, str position EXTEMPIndex ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "A unique value, greater than zero, for each temperature sensor in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each temperature sensor must remain constant at least from one reinitialization of the entity to the next re- initialization." SYNTAX Integer32 (0..2147483647) tempNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of temperature sensor units (regardless of their current state) present on this system." ::= { temperature 1 } tempTable OBJECT-TYPE SYNTAX SEQUENCE OF EXTEMPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of temperature sensor entries. The number of entries is given by the value of tempNumber." ::= { temperature 2 } tempEntry OBJECT-TYPE SYNTAX EXTEMPEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular temperature sensor." INDEX { tempIndex } ::= { tempTable 1 } EXTEMPEntry ::= SEQUENCE { tempIndex EXTEMPIndex, tempTemp Integer32, tempLowerAlarm Integer32, tempHighAlarm Integer32, tempCriticalLimit Integer32, tempPosition DisplayString } tempIndex OBJECT-TYPE SYNTAX EXTEMPIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value, greater than zero, for each temperature sensor. It is recommended that values are assigned contiguously starting from 1. The value for each temperature sensor must remain constant at least from one reinitialization of the entity to the next reinitialization." ::= { tempEntry 1 } tempTemp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The temperature reported by the temperature sensor in degrees Celsius." ::= { tempEntry 2 } tempLowerAlarm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The lower alarm limit of the temperature sensor in degrees Celsius." ::= { tempEntry 3 } tempHighAlarm OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The high temperature alarm limit of the temperature sensor in degrees Celsius." ::= { tempEntry 4 } tempCriticalLimit OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The critical temperature alarm limit of the temperature sensor in degrees Celsius." ::= { tempEntry 5 } tempPosition OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing information about the location of the temperature sensor in the device. This value can be an empty string." ::= { tempEntry 6 } --- FAN -- int index, str status, str speedrate, str mode EXFANIndex ::= TEXTUAL-CONVENTION DISPLAY-HINT "d" STATUS current DESCRIPTION "A unique value, greater than zero, for each fan unit in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each fan unit must remain constant at least from one reinitialization of the entity to the next reinitialization." SYNTAX Integer32 (0..2147483647) fanNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of fan units (regardless of their current state) present on this system." ::= { fan 1 } fanTable OBJECT-TYPE SYNTAX SEQUENCE OF EXFANEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of fan unit entities. The number of entries is given by the value of fanNumber." ::= { fan 2 } fanEntry OBJECT-TYPE SYNTAX EXFANEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular fan unit." INDEX { fanIndex } ::= { fanTable 1 } EXFANEntry ::= SEQUENCE { fanIndex EXFANIndex, fanStatus DisplayString, fanSpeedRate Gauge32, fanMode DisplayString } fanIndex OBJECT-TYPE SYNTAX EXFANIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value, greater than zero, for each fan unit. It is recommended that values are assigned contiguously starting from 1. The value for each fan unit must remain constant at least from one reinitialization of the entity to the next reinitialization." ::= { fanEntry 1 } fanStatus OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing information about the fan unit's status." ::= { fanEntry 2 } fanSpeedRate OBJECT-TYPE SYNTAX Gauge32 (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Contains the speed rate of the fan in percent." ::= { fanEntry 3 } fanMode OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing information about the fan's run mode." ::= { fanEntry 4 } -- Transceiver --- int.2 transceiverIndex, --- int.2 transmitPower, int.2 transmitHighAlarm, int.2 transmitHighWarn, int.2 transmitLowWarn, int.2 transmitLowAlarm, --- int.2 receivePower, int.2 receiveHighAlarm, int.2 receiveHighWarn, int.2 receiveLowWarn, int.2 receiveLowAlarm EXTransceiverIndex ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-1" STATUS current DESCRIPTION "A unique value, greater than zero, for each SFP/SFP+/QSFP/... module. The value is the module's port number times 10 plus the subport- number on split ports. So port 5 would be 50 and port 42/3 would be 423. The value for each module must remain constant at least from one reinitialization of the entity to the next reinitialization." SYNTAX Integer32 (0..2147483647) transceiverNumber OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of SFP/SFP+/QSFP/... modules (regardless of their current state) present on this system." ::= { transceiver 1 } transceiverTable OBJECT-TYPE SYNTAX SEQUENCE OF EXTransceiverEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A list of SFP/SFP+/QSFP/... module entities. The number of entries is given by the value of fanNumber." ::= { transceiver 2 } transceiverEntry OBJECT-TYPE SYNTAX EXTransceiverEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry containing management information applicable to a particular SFP/SFP+/QSFP/... module." INDEX { transIndex } ::= { transceiverTable 1 } EXTransceiverEntry ::= SEQUENCE { transIndex EXTransceiverIndex, transName DisplayString, transDiagnosticImplemented INTEGER, transOpticalTransmitPower DisplayString, transOpticalTransmitHighAlarm DisplayString, transOpticalTransmitHighWarn DisplayString, transOpticalTransmitLowWarn DisplayString, transOpticalTransmitLowAlarm DisplayString, transOpticalReceivePower DisplayString, transOpticalReceiveHighAlarm DisplayString, transOpticalReceiveHighWarn DisplayString, transOpticalReceiveLowWarn DisplayString, transOpticalReceiveLowAlarm DisplayString } transIndex OBJECT-TYPE SYNTAX EXTransceiverIndex MAX-ACCESS not-accessible STATUS current DESCRIPTION "A unique value, greater than zero, for each SFP/SFP+/QSFP/... module. The value is the module's port number times 10 plus the subport- number on split ports. So port 5 would be 50 and port 42/3 would be 423. The value for each module must remain constant at least from one reinitialization of the entity to the next reinitialization." ::= { transceiverEntry 1 } transName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing the port name of the SFP/SFP+/QSFP/... module." ::= { transceiverEntry 2 } transDiagnosticImplemented OBJECT-TYPE SYNTAX INTEGER { true(1), false(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This value is true(1) if the SFP/SFP+/QSFP/... module implements diagnostics or false(2) if not. If false(2), all the following values are invalid." ::= { transceiverEntry 3 } transOpticalTransmitPower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This value contains the optical transmission power as a decimal stringified value with two decimal points. Can also be 'nan' if the sensor does not report a valid value." ::= { transceiverEntry 4 } transOpticalTransmitHighAlarm OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This value contains the optical transmission power's high alarm value as a decimal stringified value with two decimal points. Can also be 'nan' if the sensor does not report a valid value." ::= { transceiverEntry 5 } transOpticalTransmitHighWarn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This value contains the optical transmission power's high warn value as a decimal stringified value with two decimal points. Can also be 'nan' if the sensor does not report a valid value." ::= { transceiverEntry 6 } transOpticalTransmitLowWarn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This value contains the optical transmission power's low warn value as a decimal stringified value with two decimal points. Can also be 'nan' if the sensor does not report a valid value." ::= { transceiverEntry 7 } transOpticalTransmitLowAlarm OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This value contains the optical transmission power's low alarm value as a decimal stringified value with two decimal points. Can also be 'nan' if the sensor does not report a valid value." ::= { transceiverEntry 8 } transOpticalReceivePower OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This value contains the optical receive power as a decimal stringified value with two decimal points. Can also be 'nan' if the sensor does not report a valid value." ::= { transceiverEntry 9 } transOpticalReceiveHighAlarm OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This value contains the optical receive power's high alarm value as a decimal stringified value with two decimal points. Can also be 'nan' if the sensor does not report a valid value." ::= { transceiverEntry 10 } transOpticalReceiveHighWarn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This value contains the optical receive power's high warn value as a decimal stringified value with two decimal points. Can also be 'nan' if the sensor does not report a valid value." ::= { transceiverEntry 11 } transOpticalReceiveLowWarn OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This value contains the optical receive power's low warn value as a decimal stringified value with two decimal points. Can also be 'nan' if the sensor does not report a valid value." ::= { transceiverEntry 12 } transOpticalReceiveLowAlarm OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-only STATUS current DESCRIPTION "This value contains the optical receive power's low alarm value as a decimal stringified value with two decimal points. Can also be 'nan' if the sensor does not report a valid value." ::= { transceiverEntry 13 } -- conformance information envConformance OBJECT IDENTIFIER ::= { environment 10 } envGroups OBJECT IDENTIFIER ::= { envConformance 1 } envCompliances OBJECT IDENTIFIER ::= { envConformance 2 } -- compliance statements envCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for Packetmaster EX environment sensors." MODULE -- this module MANDATORY-GROUPS { envTempGroup } GROUP envPSUGroup DESCRIPTION "This group is not mandatory." GROUP envTempGroup DESCRIPTION "This group is not mandatory." GROUP envFanGroup DESCRIPTION "This group is mandatory for temperature sensors in the device." GROUP transmitterGroup DESCRIPTION "This group is not mandatory." ::= { envCompliances 1 } -- units of conformance envPSUGroup OBJECT-GROUP OBJECTS { psuNumber, psuPresent, psuPower, psuType, psuAlert } STATUS current DESCRIPTION "A collection of objects providing information on the presence and status of PSU units." ::= { envGroups 1 } envTempGroup OBJECT-GROUP OBJECTS { tempNumber, tempTemp, tempLowerAlarm, tempHighAlarm, tempCriticalLimit, tempPosition } STATUS current DESCRIPTION "A collection of objects providing information on the status of temperature sensors." ::= { envGroups 2 } envFanGroup OBJECT-GROUP OBJECTS { fanNumber, fanStatus, fanSpeedRate, fanMode } STATUS current DESCRIPTION "A collection of objects providing information on the status of fan units." ::= { envGroups 3 } transmitterGroup OBJECT-GROUP OBJECTS { transceiverNumber, transName, transDiagnosticImplemented, transOpticalTransmitPower, transOpticalTransmitHighAlarm, transOpticalTransmitHighWarn, transOpticalTransmitLowWarn, transOpticalTransmitLowAlarm, transOpticalReceivePower, transOpticalReceiveHighAlarm, transOpticalReceiveHighWarn, transOpticalReceiveLowWarn, transOpticalReceiveLowAlarm } STATUS current DESCRIPTION "A collection of objects providing information on the status of SFPs." ::= { envGroups 4 } END