-- OLD-CISCO-ENV-MIB.my: Cisco Environmental Monitor MIB file
--
-- May 1994, Jeffrey T. Johnson
--
-- Copyright (c) 1994 by cisco Systems, Inc.
-- All rights reserved.
--
-- *****************************************************************
--
OLD-CISCO-ENV-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
local
FROM CISCO-SMI;
lenv OBJECT IDENTIFIER ::= { local 1 }
-- lenv is the same as lsystem
-- we're just placing the envmon stuff under a new name for mibcomp
envPresent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is there an environmental monitor card in
this box?, 0 - No, 1-AGS card present, wrong
firmware, 2-AGS CARD present, firmware ok,
3-7000 support"
::= { lenv 77 }
envTestPt1Descr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description of the test point 1. Typically
ambient air or the temperature of air
entering the router"
::= { lenv 78 }
envTestPt1Measure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current value of test point 1. Typically a
temperature in centigrade."
::= { lenv 79 }
envTestPt2Descr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description of the test point 2. Typically
airflow or the temperature of air leaving the
router"
::= { lenv 80 }
envTestPt2Measure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current value of test point 2. Typically a
temperature in centigrade."
::= { lenv 81 }
envTestPt3Descr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description of the test point 3. Typically
+5 volt"
::= { lenv 82 }
envTestPt3Measure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current value of test point 3. Typically the
value in millivolts of the +5v supply"
::= { lenv 83 }
envTestPt4Descr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description of the test point 4. Typically
+12 volt"
::= { lenv 84 }
envTestPt4Measure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current value of test point 4. Typically the
value in millivolts of the +12v supply"
::= { lenv 85 }
envTestPt5Descr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description of the test point 5. Typically
-12 volt"
::= { lenv 86 }
envTestPt5Measure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current value of test point 5. Typically the
value in millivolts of the -12v supply"
::= { lenv 87 }
envTestPt6Descr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description of the test point 6. Typically
-5 volt"
::= { lenv 88 }
envTestPt6Measure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current value of test point 6. Typically the
value in millivolts of the -5v supply"
::= { lenv 89 }
envTestPt1MarginVal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value at which the router will shutdown.
Typically the ambient air temperature that
will shut the router down. (e.g. 43)"
::= { lenv 90 }
envTestPt2MarginVal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value at which the router will shutdown.
Typically the airflow air temperature that
will shut the router down. (e.g. 58)"
::= { lenv 91 }
envTestPt3MarginPercent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"+/- Percentage that will shut the router
down, (e.g. 10%) typically +5 volt"
::= { lenv 92 }
envTestPt4MarginPercent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"+/- Percentage that will shut the router
down, (e.g. 15%) typically +12 volt"
::= { lenv 93 }
envTestPt5MarginPercent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"+/- Percentage that will shut the router
down, (e.g. 15%) typically -12 volt"
::= { lenv 94 }
envTestPt6MarginPercent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"+/- Percentage that will shut the router
down, (e.g. 10%) typically -5 volt"
::= { lenv 95 }
envTestPt1last OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value of TestPt1 when last shutdown
occurred."
::= { lenv 96 }
envTestPt2last OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value of TestPt2 when last shutdown
occurred."
::= { lenv 97 }
envTestPt3last OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value of TestPt3 when last shutdown
occurred."
::= { lenv 98 }
envTestPt4last OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value of TestPt4 when last shutdown
occurred."
::= { lenv 99 }
envTestPt5last OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value of TestPt5 when last shutdown
occurred."
::= { lenv 100 }
envTestPt6last OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Value of TestPt6 when last shutdown
occurred."
::= { lenv 101 }
envTestPt1warn OBJECT-TYPE
SYNTAX INTEGER {
warning(1),
noWarning(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is this test point at a warning level?"
::= { lenv 102 }
envTestPt2warn OBJECT-TYPE
SYNTAX INTEGER {
warning(1),
noWarning(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is this test point at a warning level?"
::= { lenv 103 }
envTestPt3warn OBJECT-TYPE
SYNTAX INTEGER {
warning(1),
noWarning(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is this test point at a warning level?"
::= { lenv 104 }
envTestPt4warn OBJECT-TYPE
SYNTAX INTEGER {
warning(1),
noWarning(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is this test point at a warning level?"
::= { lenv 105 }
envTestPt5warn OBJECT-TYPE
SYNTAX INTEGER {
warning(1),
noWarning(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is this test point at a warning level?"
::= { lenv 106 }
envTestPt6warn OBJECT-TYPE
SYNTAX INTEGER {
warning(1),
noWarning(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is this test point at a warning level?"
::= { lenv 107 }
envFirmVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Description of Environmental Card firmware"
::= { lenv 108 }
envTechnicianID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Technician ID"
::= { lenv 109 }
envType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of environmental card"
::= { lenv 110 }
envBurnDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The calibration / burn in date"
::= { lenv 111 }
envSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial Number of environmental monitor card"
::= { lenv 112 }
END